Sample records for statistical lens sample

  1. Proper and Paradigmatic Metonymy as a Lens for Characterizing Student Conceptions of Distributions and Sampling

    ERIC Educational Resources Information Center

    Noll, Jennifer; Hancock, Stacey

    2015-01-01

    This research investigates what students' use of statistical language can tell us about their conceptions of distribution and sampling in relation to informal inference. Prior research documents students' challenges in understanding ideas of distribution and sampling as tools for making informal statistical inferences. We know that these…

  2. A First Assignment to Create Student Buy-In in an Introductory Business Statistics Course

    ERIC Educational Resources Information Center

    Newfeld, Daria

    2016-01-01

    This paper presents a sample assignment to be administered after the first two weeks of an introductory business focused statistics course in order to promote student buy-in. This assignment integrates graphical displays of data, descriptive statistics and cross-tabulation analysis through the lens of a marketing analysis study. A marketing sample…

  3. Can salt on an optical rain gauge lens affect performance?

    NASA Technical Reports Server (NTRS)

    Bliven, Larry F.

    1994-01-01

    The optical rain gauge (ORG) by ScTI is designed to be tolerant to reduction of infrared beam intensity due to a dirty lens. Recently there is interest in long term use of optical gauges onboard buoys at sea. Because of logistics, these systems are serviced infrequently, i.e., every several months. Due to the proximity of the gauges to the sea surface, salt can be expected to be deposited on the lens. To obtain an indication of the potential for dirty lens to affect the ORG calibration, two simple experiments were conducted. In the control experiment, a sample ORG was compared to three other ORG's during natural rain events. Next a translucent mask was placed on the transmitter lens of the sample ORG and again data were collected under natural rain conditions. The mask reduced the gain of the perturbed ORG by about 30%. The perturbed ORG operated rather well in that the mask only causes a change in the gain and does not cause data drop out at low rain rates. However, the reduced gain would seriously impact an assessment of rain statistics.

  4. The Sloan Lens ACS Survey. I. A Large Spectroscopically Selected Sample of Massive Early-Type Lens Galaxies

    NASA Technical Reports Server (NTRS)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Moustakas, Leonidas A.

    2006-01-01

    The Sloan Lens ACS (SLACS) Survey is an efficient Hubble Space Telescope (HST) Snapshot imaging survey for new galaxy-scale strong gravitational lenses. The targeted lens candidates are selected spectroscopically from the Sloan Digital Sky Survey (SDSS) database of galaxy spectra for having multiple nebular emission lines at a redshift significantly higher than that of the SDSS target galaxy. The SLACS survey is optimized to detect bright early-type lens galaxies with faint lensed sources in order to increase the sample of known gravitational lenses suitable for detailed lensing, photometric, and dynamical modeling. In this paper, the first in a series on the current results of our HST Cycle 13 imaging survey, we present a catalog of 19 newly discovered gravitational lenses, along with nine other observed candidate systems that are either possible lenses, nonlenses, or nondetections. The survey efficiency is thus >=68%. We also present Gemini 8 m and Magellan 6.5 m integral-field spectroscopic data for nine of the SLACS targets, which further support the lensing interpretation. A new method for the effective subtraction of foreground galaxy images to reveal faint background features is presented. We show that the SLACS lens galaxies have colors and ellipticities typical of the spectroscopic parent sample from which they are drawn (SDSS luminous red galaxies and quiescent MAIN sample galaxies), but are somewhat brighter and more centrally concentrated. Several explanations for the latter bias are suggested. The SLACS survey provides the first statistically significant and homogeneously selected sample of bright early-type lens galaxies, furnishing a powerful probe of the structure of early-type galaxies within the half-light radius. The high confirmation rate of lenses in the SLACS survey suggests consideration of spectroscopic lens discovery as an explicit science goal of future spectroscopic galaxy surveys.

  5. The Correlation between Daily Lens Wear Duration and Dry Eye Syndrome.

    PubMed

    Lubis, Rodiah Rahmawaty; Gultom, Monica Tumiar Hanna

    2018-05-20

    To analyze the correlation between the daily lens wear duration and dry eye syndrome. This study was an analytic cross sectional study using consecutive sampling conducted among the students in Economy and Bussiness Faculty and Faculty of Humanities in University of Sumatera Utara aged between 17 to 23 that wore contact lens continously for at least a year and 5 days a week. The symptoms were assessed using Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and interview about their contact lens comfort; eye drops usage, contact lens washing habit, daily circumstances, places to buy contact lens and personal experince in wearing contact lens. The questionnaire was completed by 53 students. All of them were female and wore softlens wearers. The mean duration of daily wear was 8.19 ± 2.20 hours. The most common symptom experienced was dry eye and the least symptom experienced was removing lens. The most frequent symptom experienced was closing eyes and the least frequent symptom experienced was removing lenses. This study used Exact Test as analysis statistic method. The result was p > 0.05 which means there is no correlation between daily lens wear duration and dry eye syndrome. This study showed that dry eye syndrome was not correlated with daily lens wear duration, but affected by many factors such as contact lens, lens care solution, eye drops usage and environment.

  6. Post-lens tear turbidity and visual quality after scleral lens wear.

    PubMed

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity. © 2017 Optometry Australia.

  7. RELICS: Strong Lens Models for Five Galaxy Clusters from the Reionization Lensing Cluster Survey

    NASA Astrophysics Data System (ADS)

    Cerny, Catherine; Sharon, Keren; Andrade-Santos, Felipe; Avila, Roberto J.; Bradač, Maruša; Bradley, Larry D.; Carrasco, Daniela; Coe, Dan; Czakon, Nicole G.; Dawson, William A.; Frye, Brenda L.; Hoag, Austin; Huang, Kuang-Han; Johnson, Traci L.; Jones, Christine; Lam, Daniel; Lovisari, Lorenzo; Mainali, Ramesh; Oesch, Pascal A.; Ogaz, Sara; Past, Matthew; Paterno-Mahler, Rachel; Peterson, Avery; Riess, Adam G.; Rodney, Steven A.; Ryan, Russell E.; Salmon, Brett; Sendra-Server, Irene; Stark, Daniel P.; Strolger, Louis-Gregory; Trenti, Michele; Umetsu, Keiichi; Vulcani, Benedetta; Zitrin, Adi

    2018-06-01

    Strong gravitational lensing by galaxy clusters magnifies background galaxies, enhancing our ability to discover statistically significant samples of galaxies at {\\boldsymbol{z}}> 6, in order to constrain the high-redshift galaxy luminosity functions. Here, we present the first five lens models out of the Reionization Lensing Cluster Survey (RELICS) Hubble Treasury Program, based on new HST WFC3/IR and ACS imaging of the clusters RXC J0142.9+4438, Abell 2537, Abell 2163, RXC J2211.7–0349, and ACT-CLJ0102–49151. The derived lensing magnification is essential for estimating the intrinsic properties of high-redshift galaxy candidates, and properly accounting for the survey volume. We report on new spectroscopic redshifts of multiply imaged lensed galaxies behind these clusters, which are used as constraints, and detail our strategy to reduce systematic uncertainties due to lack of spectroscopic information. In addition, we quantify the uncertainty on the lensing magnification due to statistical and systematic errors related to the lens modeling process, and find that in all but one cluster, the magnification is constrained to better than 20% in at least 80% of the field of view, including statistical and systematic uncertainties. The five clusters presented in this paper span the range of masses and redshifts of the clusters in the RELICS program. We find that they exhibit similar strong lensing efficiencies to the clusters targeted by the Hubble Frontier Fields within the WFC3/IR field of view. Outputs of the lens models are made available to the community through the Mikulski Archive for Space Telescopes.

  8. Hydrophilic acrylic intraocular lens as a drug-delivery system for fourth-generation fluoroquinolones.

    PubMed

    Kleinmann, Guy; Apple, David J; Chew, Jesse; Hunter, Brian; Stevens, Scott; Larson, Scott; Mamalis, Nick; Olson, Randall J

    2006-10-01

    To evaluate the ability and safety of a hydrophilic acrylic intraocular lens (IOL) as a drug-delivery system for commercially available gatifloxacin and moxifloxacin. David J. Apple, MD, Laboratories for Ophthalmic Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. Thirty rabbits were divided into 2 similar groups. In Group A (15 rabbits, 30 eyes), hydrophilic acrylic IOLs (C-flex, Rayner Intraocular Lenses, Ltd.) presoaked for 24 hours in commercially available solutions of gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL were implanted after evacuation of the crystalline lens. Group B (15 rabbits, 30 eyes) had topical preoperative and postoperative cataract prophylaxis with gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL; IOLs that were not presoaked were also implanted after evacuation of the crystalline lenses. In both groups, aqueous humor samples were taken 4, 8, or 12 hours after IOL implantation (5 eyes at each time point) to determine the antibiotic concentrations. Clinical examinations were performed 24 hours postoperatively. The antibiotic concentrations in Group A (presoaked IOLs) were statistically significantly higher than those in Group B (topical) for both antibiotics in all postoperative samples except moxifloxacin at 12 hours. In both groups, there was no statistically significant difference between the concentrations of the 2 antibiotics. No eye showed signs of clinical toxicity. Results show the C-flex IOL is a safe and effective drug-delivery system for fourth-generation fluoroquinolones.

  9. Galaxy mergers and gravitational lens statistics

    NASA Technical Reports Server (NTRS)

    Rix, Hans-Walter; Maoz, Dan; Turner, Edwin L.; Fukugita, Masataka

    1994-01-01

    We investigate the impact of hierarchical galaxy merging on the statistics of gravitational lensing of distant sources. Since no definite theoretical predictions for the merging history of luminous galaxies exist, we adopt a parameterized prescription, which allows us to adjust the expected number of pieces comprising a typical present galaxy at z approximately 0.65. The existence of global parameter relations for elliptical galaxies and constraints on the evolution of the phase space density in dissipationless mergers, allow us to limit the possible evolution of galaxy lens properties under merging. We draw two lessons from implementing this lens evolution into statistical lens calculations: (1) The total optical depth to multiple imaging (e.g., of quasars) is quite insensitive to merging. (2) Merging leads to a smaller mean separation of observed multiple images. Because merging does not reduce drastically the expected lensing frequency, it cannot make lambda-dominated cosmologies compatible with the existing lensing observations. A comparison with the data from the Hubble Space Telescope (HST) Snapshot Survey shows that models with little or no evolution of the lens population are statistically favored over strong merging scenarios. A specific merging scenario proposed to Toomre can be rejected (95% level) by such a comparison. Some versions of the scenario proposed by Broadhurst, Ellis, & Glazebrook are statistically acceptable.

  10. Validity of strong lensing statistics for constraints on the galaxy evolution model

    NASA Astrophysics Data System (ADS)

    Matsumoto, Akiko; Futamase, Toshifumi

    2008-02-01

    We examine the usefulness of the strong lensing statistics to constrain the evolution of the number density of lensing galaxies by adopting the values of the cosmological parameters determined by recent Wilkinson Microwave Anisotropy Probe observation. For this purpose, we employ the lens-redshift test proposed by Kochanek and constrain the parameters in two evolution models, simple power-law model characterized by the power-law indexes νn and νv, and the evolution model by Mitchell et al. based on cold dark matter structure formation scenario. We use the well-defined lens sample from the Sloan Digital Sky Survey (SDSS) and this is similarly sized samples used in the previous studies. Furthermore, we adopt the velocity dispersion function of early-type galaxies based on SDSS DR1 and DR5. It turns out that the indexes of power-law model are consistent with the previous studies, thus our results indicate the mild evolution in the number and velocity dispersion of early-type galaxies out to z = 1. However, we found that the values for p and q used by Mitchell et al. are inconsistent with the presently available observational data. More complete sample is necessary to withdraw more realistic determination on these parameters.

  11. Constraints on cosmological parameters from the analysis of the cosmic lens all sky survey radio-selected gravitational lens statistics.

    PubMed

    Chae, K-H; Biggs, A D; Blandford, R D; Browne, I W A; De Bruyn, A G; Fassnacht, C D; Helbig, P; Jackson, N J; King, L J; Koopmans, L V E; Mao, S; Marlow, D R; McKean, J P; Myers, S T; Norbury, M; Pearson, T J; Phillips, P M; Readhead, A C S; Rusin, D; Sykes, C M; Wilkinson, P N; Xanthopoulos, E; York, T

    2002-10-07

    We derive constraints on cosmological parameters and the properties of the lensing galaxies from gravitational lens statistics based on the final Cosmic Lens All Sky Survey data. For a flat universe with a classical cosmological constant, we find that the present matter fraction of the critical density is Omega(m)=0.31(+0.27)(-0.14) (68%)+0.12-0.10 (syst). For a flat universe with a constant equation of state for dark energy w=p(x)(pressure)/rho(x)(energy density), we find w<-0.55(+0.18)(-0.11) (68%).

  12. Primate lens capsule elasticity assessed using Atomic Force Microscopy

    PubMed Central

    Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie

    2011-01-01

    The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953

  13. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users.

    PubMed

    Thakur, Deeksha V; Gaikwad, Ujjwala N

    2014-08-01

    With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Four samples each from 50 participants (n=200) were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey's agar and Sabouraud's dextrose agar. Organisms were identified using standard laboratory protocols. Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62%) and lens care solution (42%), respectively. The most frequently isolated contaminant was Staphylococcus aureus (21%) followed by Pseudomonas species (19.5%). Majority (64%) of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75%) (P<0.05). Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.

  14. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users

    PubMed Central

    Thakur, Deeksha V.; Gaikwad, Ujjwala N.

    2014-01-01

    Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200) were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey's agar and Sabouraud's dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62%) and lens care solution (42%), respectively. The most frequently isolated contaminant was Staphylococcus aureus (21%) followed by Pseudomonas species (19.5%). Majority (64%) of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75%) (P<0.05). Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required. PMID:25297366

  15. Gravitational lens effects of a cosmological density of compact objects

    NASA Technical Reports Server (NTRS)

    Canizares, C. R.

    1983-01-01

    Amplification of quasar light by a cosmological density of compact objects causes significant effects on many quasars in magnitude-limited samples. For lens masses solar mass less than 100,000 solar mass the continuum would be amplified by a magnitude or more but the line emission would not. Examination of the UV selected sample of Marshall et al. (1983) gives limits to more than 90 percent statistical confidence of Omega(c) less than 0.1 for a mass between 200 and 100,000 solar mass, where Omega(c) is the mean density of objects of mass M relative to the closure density. Preliminary results from an X-ray selected sample may probe to more than 0.1 solar mass and give a value for Omega(c) of less than one. These limits indicate that the remnants of an early population of massive stars cannot make a cosmologically significant contribution to the mass density of the universe. On a separate topic, recent work on the enhanced surface density of quasars near galaxies due to lensing by stars in the galaxy halos is reviewed.

  16. Determinants of Linear Judgment: A Meta-Analysis of Lens Model Studies

    ERIC Educational Resources Information Center

    Karelaia, Natalia; Hogarth, Robin M.

    2008-01-01

    The mathematical representation of E. Brunswik's (1952) lens model has been used extensively to study human judgment and provides a unique opportunity to conduct a meta-analysis of studies that covers roughly 5 decades. Specifically, the authors analyzed statistics of the "lens model equation" (L. R. Tucker, 1964) associated with 249 different…

  17. Peripheral Optics with Bifocal Soft and Corneal Reshaping Contact Lenses

    PubMed Central

    Ticak, Anita; Walline, Jeffrey J.

    2012-01-01

    Purpose To determine whether bifocal soft contact lenses with a distance center design provide myopic defocus to the peripheral retina similar to corneal reshaping contact lenses. Methods Myopic subjects underwent five cycloplegic autorefraction readings centrally and at 10, 20, and 30 degrees temporally, nasally, superiorly, inferiorly while wearing a Proclear Multifocal “D” contact lens with a +2.00 D add (CooperVision, Fairport, NY) and after wearing a Corneal Refractive Therapy (Paragon Vision Sciences, Mesa, AZ) contact lens for two weeks Results Fourteen subjects completed the study. Nine (64%) were female, and 12 (86%) were Caucasian. The average (± standard deviation) spherical equivalent non-cycloplegic manifest refraction for the right eye was −2.84 ± 1.29 D. The average logMAR best-corrected, binocular high contrast visual acuity was −0.17 ± 0.15 while wearing the bifocal soft contact lens, and −0.09 ± 0.16 following corneal reshaping contact lens wear (ANOVA, p = 0.27). The orthokeratology contact lens yielded a more myopic peripheral optical profile than the soft bifocal contact lens at 20 and 30 degrees eccentricity (except inferior at 20 degrees); the two modalities were similar at 10 degrees eccentricity. Conclusions Our data suggest that the two modalities are dissimilar despite the statistical similarities. The corneal reshaping contact lens shows an increase in relative peripheral myopic refraction, a pattern achieved by other studies, but the bifocal lens does not exhibit such a pattern. The low statistical power of the study could be a reason for a lack of providing statistical difference in other positions of gaze, but the graphical representation of the data shows a marked difference in peripheral optical profile between the two modalities. More sophisticated methods of measuring the peripheral optical profile may be necessary to accurately compare the two modalities and to determine the true optical effect of the bifocal soft contact lens on the peripheral retina. PMID:23222924

  18. Distribution of the Crystalline Lens Power In Vivo as a Function of Age.

    PubMed

    Jongenelen, Sien; Rozema, Jos J; Tassignon, Marie-José

    2015-11-01

    To observe the age-related changes in crystalline lens power in vivo in a noncataractous European population. Data were obtained though Project Gullstrand, a multicenter population study with data from healthy phakic subjects between 20 and 85 years old. One randomly selected eye per subject was used. Lens power was calculated using the modified Bennett-Rabbetts method, using biometry data from an autorefractometer, Oculus Pentacam, and Haag-Streit Lenstar. The study included 1069 Caucasian subjects (490 men, 579 women) with a mean age of 44.2 ± 14.2 years and mean lens power of 24.96 ± 2.18 diopters (D). The average lens power showed a statistically significant decrease as a function of age, with a steeper rate of decrease after the age of 55. The highest crystalline lens power was found in emmetropic eyes and eyes with a short axial length. The correlation of lens power with different refractive components was statistically significant for axial length (r = -0.523, P < 0.01) and anterior chamber depth (r = -0.161, P < 0.01), but not for spherical equivalent and corneal power (P > 0.05). This in vivo study showed a monotonous decrease in crystalline lens power with age, with a steeper decline after 55 years. While this finding fundamentally concurs with previous in vivo studies, it is at odds with studies performed on donor eyes that reported lens power increases after the age of 55.

  19. Self-referencing remote optical probe

    DOEpatents

    O'Rourke, Patrick E.; Prather, William S.; Livingston, Ronald R.

    1991-01-01

    A probe for remote spectrometric measurements of fluid samples having a hollow probe body with a sliding reflective plug therein and a lens at one end, ports for admitting and expelling the fluid sample and a means for moving the reflector so that reference measurement can be made with the reflector in a first position near the lens and a sample measurement can be made with the reflector away from the lens and the fluid sample between the reflector and the lens. Comparison of the two measurements will yield the composition of the fluid sample. The probe is preferably used for remote measurements and light is carried to and from the probe via fiber optic cables.

  20. Self-referencing remote optical probe

    DOEpatents

    O'Rourke, P.E.; Prather, W.S.; Livingston, R.R.

    1991-08-13

    A probe is described for remote spectrometric measurements of fluid samples having a hollow probe body with a sliding reflective plug therein and a lens at one end, ports for admitting and expelling the fluid sample and a means for moving the reflector so that reference measurement can be made with the reflector in a first position near the lens and a sample measurement can be made with the reflector away from the lens and the fluid sample between the reflector and the lens. Comparison of the two measurements will yield the composition of the fluid sample. The probe is preferably used for remote measurements and light is carried to and from the probe via fiber optic cables. 3 figures.

  1. Optical Coherence Tomography Based Estimates of Crystalline Lens Volume, Equatorial Diameter, and Plane Position.

    PubMed

    Martinez-Enriquez, Eduardo; Sun, Mengchan; Velasco-Ocana, Miriam; Birkenfeld, Judith; Pérez-Merino, Pablo; Marcos, Susana

    2016-07-01

    Measurement of crystalline lens geometry in vivo is critical to optimize performance of state-of-the-art cataract surgery. We used custom-developed quantitative anterior segment optical coherence tomography (OCT) and developed dedicated algorithms to estimate lens volume (VOL), equatorial diameter (DIA), and equatorial plane position (EPP). The method was validated ex vivo in 27 human donor (19-71 years of age) lenses, which were imaged in three-dimensions by OCT. In vivo conditions were simulated assuming that only the information within a given pupil size (PS) was available. A parametric model was used to estimate the whole lens shape from PS-limited data. The accuracy of the estimated lens VOL, DIA, and EPP was evaluated by comparing estimates from the whole lens data and PS-limited data ex vivo. The method was demonstrated in vivo using 2 young eyes during accommodation and 2 cataract eyes. Crystalline lens VOL was estimated within 96% accuracy (average estimation error across lenses ± standard deviation: 9.30 ± 7.49 mm3). Average estimation errors in EPP were below 40 ± 32 μm, and below 0.26 ± 0.22 mm in DIA. Changes in lens VOL with accommodation were not statistically significant (2-way ANOVA, P = 0.35). In young eyes, DIA decreased and EPP increased statistically significantly with accommodation (P < 0.001) by 0.14 mm and 0.13 mm, respectively, on average across subjects. In cataract eyes, VOL = 205.5 mm3, DIA = 9.57 mm, and EPP = 2.15 mm on average. Quantitative OCT with dedicated image processing algorithms allows estimation of human crystalline lens volume, diameter, and equatorial lens position, as validated from ex vivo measurements, where entire lens images are available.

  2. Effect of three months of soft contact lens wear on conjunctival cytology.

    PubMed

    Sapkota, Kishor; Franco, Sandra; Sampaio, Paula; Lira, Madalena

    2016-07-01

    The purpose of this study was to investigate the effect of three months of soft contact lens wear on conjunctival goblet cell density and epithelial cell morphology. This was a longitudinal clinical trial. Conjunctival impression cytology was performed on the superior palpebral conjunctiva in fifty-four eyes of twenty-seven neophyte contact lens wearers before and after three months of contact lens wear. Goblet cell density was determined by optical microscopy and epithelial cell morphology was classified according to the Tseng classification. Changes in goblet cell density as well as epithelial cell grading were determined. The effects of lens material and wearing modality on cytological changes were also investigated. Goblet cell density reduced significantly by 85 ± 151 cells/mm(2) (p < 0.001) after three months of contact lens wear. Reduction in goblet cell density was associated with lens materials; it was higher in conventional hydrogel lenses in comparison to silicone-hydrogel lenses (p = 0.008). The highest reduction in goblet cell density was found with Nelfilcon A lens wear (p = 0.002) and the lowest with Comfilcon A lens wear (p = 0.414). There was no statistically significant difference in grading of epithelial metaplasia before and after three months of contact lens wear (p = 0.075). Age was not correlated with the reduction in goblet cell density (r = -0.196, p = 0.160) but it was associated with the change in epithelial cell morphology (p = 0.036). Three months of soft contact lens wear statistically significantly reduced goblet cell density; however, no significant changes were found in the grading of epithelial metaplasia. Contact lenses with lower oxygen permeability, higher Young modulus and higher thickness highly affected the conjunctival cytology. © 2016 Optometry Australia.

  3. Which soft contact lens power is better for piggyback fitting in keratoconus?

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose Manuel

    2013-02-01

    To evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus. Nineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of -3.00, -1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated. Negative- and plano-powered soft lenses flattened (p<0.05 in all cases), whereas positive-powered lenses did not induce any significant changes (p>0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (p<0.05 in both cases) and increased with +3.00 D lenses (p=0.03) in comparison to the naked eye. No statistically significant differences were found in MFE with any soft lens power in comparison to the naked eye (p>0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p<0.05 in all cases). No statistically differences were found in HOA RMS and spherical-like aberration (both p>0.05). Statistically differences were found in coma-like and secondary astigmatism (both p<0.05). Negative-powered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Discovery of four doubly imaged quasar lenses from the Sloan digital sky survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inada, Naohisa; Oguri, Masamune; Rusu, Cristian E.

    2014-06-01

    We report the discovery of four doubly imaged quasar lenses. All the four systems are selected as lensed quasar candidates from the Sloan Digital Sky Survey data. We confirm their lensing hypothesis with additional imaging and spectroscopic follow-up observations. The discovered lenses are SDSS J0743+2457 with the source redshift z{sub s} = 2.165, the lens redshift z{sub l} = 0.381, and the image separation θ = 1.''034, SDSS J1128+2402 with z{sub s} = 1.608 and θ = 0.''844, SDSS J1405+0959 with z{sub s} = 1.810, z{sub l} ≈ 0.66, and θ = 1.''978, and SDSS J1515+1511 with z{sub s} =more » 2.054, z{sub l} = 0.742, and θ = 1.''989. It is difficult to estimate the lens redshift of SDSS J1128+2402 from the current data. Two of the four systems (SDSS J1405+0959 and SDSS J1515+1511) are included in our final statistical lens sample to derive constraints on dark energy and the evolution of massive galaxies.« less

  5. H-ATLAS/GAMA: magnification bias tomography. Astrophysical constraints above ∼1 arcmin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    González-Nuevo, J.; Bonavera, L.; Lapi, A.

    An unambiguous manifestation of the magnification bias is the cross-correlation between two source samples with non-overlapping redshift distributions. In this work we measure and study the cross-correlation signal between a foreground sample of GAMA galaxies with spectroscopic redshifts in the range 0.2< z <0.8, and a background sample of H-ATLAS galaxies with photometric redshifts ∼>1.2. It constitutes a substantial improvement over the cross-correlation measurements made by Gonzalez-Nuevo et al. (2014) with updated catalogues and wider area (with S / N ∼> 5 below 10 arcmin and reaching S / N ∼ 20 below 30 arcsec). The better statistics allow usmore » to split the sample in different redshift bins and to perform a tomographic analysis (with S / N ∼> 3 below 10 arcmin and reaching S / N ∼ 15 below 30 arcsec). Moreover, we implement a halo model to extract astrophysical information about the background galaxies and the deflectors that are producing the lensing link between the foreground (lenses) and background (sources) samples. In the case of the sources, we find typical mass values in agreement with previous studies: a minimum halo mass to host a central galaxy, M {sub min}∼ 10{sup 12.26} M {sub ⊙}, and a pivot halo mass to have at least one sub-halo satellite, M {sub 1∼} 10{sup 12.84} M {sub ⊙}. However, the lenses are massive galaxies or even galaxy groups/clusters, with minimum mass of M {sub min}{sup lens}∼ 10{sup 13.06} M {sub ⊙}. Above a mass of M {sub 1}{sup lens}∼ 10{sup 14.57} M {sub ⊙} they contain at least one additional satellite galaxy which contributes to the lensing effect. The tomographic analysis shows that, while M {sub 1}{sup lens} is almost redshift independent, there is a clear evolution of increase M {sub min}{sup lens} with redshift in agreement with theoretical estimations. Finally, the halo modeling allows us to identify a strong lensing contribution to the cross-correlation for angular scales below 30 arcsec. This interpretation is supported by the results of basic but effective simulations.« less

  6. Fitting Tips and Visual Rehabilitation of Irregular Cornea with a New Design of Corneoscleral Contact Lens: Objective and Subjective Evaluation

    PubMed Central

    Kishk, Hanem; Elwan, Mohamed M.; Abouelkheir, Hossam Youssef

    2018-01-01

    Objectives To study the fitting and the visual rehabilitation obtained with a corneoscleral contact lens, namely, Rose K2 XL in patients with irregular cornea. Methods This prospective study included 36 eyes of 36 patients with irregular cornea fitted with Rose K2 XL. Refractive and visual outcomes and mesopic and aberrometric parameters of fitted eyes were assessed at 2 weeks, 3 months, and 6 months after the initial lens use. Objective and subjective parameters of patient satisfaction and lens comfort were noted. Causes of lens discontinuation and complications were also recorded. Results Average logMAR VA improved significantly from 0.95 ± 0.09 without correction to 0.04 ± 0.05 six months after lens wear. Similarly, mesopic and aberrometric measures were significantly improved. Statistical analysis of the subjective patients' responses showed a significant acceptance of the lens by most of them. At the end of follow-up, the mean wearing time was 9.9 ± 2.9 hours per day. The most common cause of wearing discontinuation was persistent discomfort (16.7%) and high lens expenses(16.7%). Self-assessed questionnaire showed statistically significant improvement in nearly all measured subjective parameters. Conclusion Rose K2 XL lenses provide patients with irregular cornea with both quantitative and qualitative optimal visual function with high degree of patient comfort and satisfaction. PMID:29484205

  7. Statistical simplex approach to primary and secondary color correction in thick lens assemblies

    NASA Astrophysics Data System (ADS)

    Ament, Shelby D. V.; Pfisterer, Richard

    2017-11-01

    A glass selection optimization algorithm is developed for primary and secondary color correction in thick lens systems. The approach is based on the downhill simplex method, and requires manipulation of the surface color equations to obtain a single glass-dependent parameter for each lens element. Linear correlation is used to relate this parameter to all other glass-dependent variables. The algorithm provides a statistical distribution of Abbe numbers for each element in the system. Examples of several lenses, from 2-element to 6-element systems, are performed to verify this approach. The optimization algorithm proposed is capable of finding glass solutions with high color correction without requiring an exhaustive search of the glass catalog.

  8. Regulatory effect of Bcl-2 in ultraviolet radiation-induced apoptosis of the mouse crystalline lens

    PubMed Central

    DONG, YUCHEN; ZHENG, YAJUAN; XIAO, JUN; ZHU, CHAO; ZHAO, MEISHENG

    2016-01-01

    The aim of the present study was to analyze the role of Bcl-2 during the process of apoptosis in the mouse crystalline lens. In total, 12 normal mice served as the control group and 12 Bcl-2 knockout (K.O) mice served as the experimental group. The mouse crystalline lens was sampled for the detection of Bcl-2 and caspase-3 expression following exposure to ultraviolet (UV) radiation. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to determine Bcl-2 expression in the groups of normal mice receiving UV radiation or not receiving UV radiation. Samples of the murine crystalline lens were microscopically harvested and analyzed using western blotting. Apoptosis was detected using terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) assay. Furthermore, caspase 3 activity was examined using enzyme-linked immunosorbent assay kits, and RT-qPCR was used to analyze caspase-3 expression levels. The results of the present study demonstrated that there was no statistically significant difference in the level of Bcl-2 gene transcription between the two groups. In addition, UV radiation did not change the macrostructure of the crystalline lens in the group of normal mice or the group of Bcl-2 K.O mice. The results of the TUNEL assay indicated that the normal-UV group exhibited a more significant apoptosis level compared with the Bcl-2 K.O-UV group. Furthermore, the mRNA expression level of caspase-3 in the normal-UV group was significantly higher compared with the normal-nonUV group (P<0.05), while the levels in the Bcl-2 K.O-UV group were significantly higher compared with the Bcl-2 K.O and normal-nonUV groups (P<0.05). In addition, the mRNA expression level of caspase-3 was significantly higher in the normal-UV, as compared with the Bcl-2 K.O-UV group (P<0.05), and the variation trends in caspase-3 activity were consistent. In conclusion, the results of the present study demonstrated that Bcl-2 may have an important role in the promotion of UV-induced apoptosis in the crystalline lens. PMID:26998022

  9. Regulatory effect of Bcl-2 in ultraviolet radiation-induced apoptosis of the mouse crystalline lens.

    PubMed

    Dong, Yuchen; Zheng, Yajuan; Xiao, Jun; Zhu, Chao; Zhao, Meisheng

    2016-03-01

    The aim of the present study was to analyze the role of Bcl-2 during the process of apoptosis in the mouse crystalline lens. In total, 12 normal mice served as the control group and 12 Bcl-2 knockout (K.O) mice served as the experimental group. The mouse crystalline lens was sampled for the detection of Bcl-2 and caspase-3 expression following exposure to ultraviolet (UV) radiation. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to determine Bcl-2 expression in the groups of normal mice receiving UV radiation or not receiving UV radiation. Samples of the murine crystalline lens were microscopically harvested and analyzed using western blotting. Apoptosis was detected using terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) assay. Furthermore, caspase 3 activity was examined using enzyme-linked immunosorbent assay kits, and RT-qPCR was used to analyze caspase-3 expression levels. The results of the present study demonstrated that there was no statistically significant difference in the level of Bcl-2 gene transcription between the two groups. In addition, UV radiation did not change the macrostructure of the crystalline lens in the group of normal mice or the group of Bcl-2 K.O mice. The results of the TUNEL assay indicated that the normal-UV group exhibited a more significant apoptosis level compared with the Bcl-2 K.O-UV group. Furthermore, the mRNA expression level of caspase-3 in the normal-UV group was significantly higher compared with the normal-nonUV group (P<0.05), while the levels in the Bcl-2 K.O-UV group were significantly higher compared with the Bcl-2 K.O and normal-nonUV groups (P<0.05). In addition, the mRNA expression level of caspase-3 was significantly higher in the normal-UV, as compared with the Bcl-2 K.O-UV group (P<0.05), and the variation trends in caspase-3 activity were consistent. In conclusion, the results of the present study demonstrated that Bcl-2 may have an important role in the promotion of UV-induced apoptosis in the crystalline lens.

  10. Corneal and conjunctival epithelial staining in hydrogel contact lens wearers.

    PubMed

    Brautaset, Rune L; Nilsson, Maria; Leach, Norman; Miller, William L; Gire, Anisa; Quintero, Sam; Bergmanson, Jan P G

    2008-11-01

    The purpose of this study was to investigate the prevalence of conjunctival and corneal epithelial staining in soft contact lens wearers and to see if staining could be associated with factors such as type of lens worn, wearing time, care system, age, and sex. The records of 338 adapted hydrogel contact lens wearers were examined retrospectively. Conjunctival staining was found to be present in 32.5% of the subjects and corneal staining was found to be present in 19.5% of subjects. None of the subjects had staining above grade 2 using the Cornea and Contact Lens Research Unit scale. Because of the low prevalence of staining, the low grading of staining found and the large variation in refractive power, lens type worn, wearing modality, and solution used statistical analysis for association between staining and different factors could only be performed for the association between sex and staining and between corneal and conjunctival staining. However, no statistical significant association could be demonstrated. Despite the low prevalence of staining the conjunctiva and cornea should be examined carefully in contact lens wearers and prospective wearers because the conjunctival and corneal epithelium serve as protective barriers for the underlying layers of the cornea and conjunctiva. To allow comparison of data obtained in different studies assessing corneal staining, it is recommended that clinicians develop and adopt a universal standard protocol for this measure.

  11. Lens system for a photo ion spectrometer

    DOEpatents

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1990-01-01

    A lens system in a photo ion spectrometer for manipulating a primary ion beam and ionized atomic component. The atomic components are removed from a sample by a primary ion beam using the lens system, and the ions are extracted for analysis. The lens system further includes ionization resistant coatings for protecting the lens system.

  12. Microbial Keratitis in Kingdom of Bahrain: Clinical and Microbiology Study

    PubMed Central

    Al-Yousuf, Nada

    2009-01-01

    Background: Microbial keratitis is a potentially vision threatening condition worldwide. Knowing the predisposing factors and etiologic microorganism can help control and prevent this problem. This is the first study of its kind in Kingdom of Bahrain. Objective: To study the profile of microbial keratitis in Bahrain with special focus on risk factors, clinical outcome and microbilogical results. Methods: A retrospective analysis of all patients admitted in Salmaniya Medical Complex over a period of three years from January 2005 to January 2007 was performed. A total of 285 patients with keratitis were analysed. Non infectious corneal ulceration were excluded. Data collected from medical records were demographic features, predisposing factors, history of corneal trauma, associated ocular conditions, visual acuity at the time of presentation and the clinical course. Predisposing risk factors measured were contact lens use, presence of blepharitis, diabetes, lid abnormalities, dry eyes, keratoplasty and refractive surgery. For contact lens wearers any contact lens related risk factors that can lead to keratitis were measured. Pearson's chi-square test was used to carry out statistical analysis wherever required. Results: Contact lens wear, as a risk factor for microbial keratitis, formed 40% of the total study population. Other risk factors identified were dry eyes 24 cases (8%), 10 blepharitis (3%), 22 trauma (8%), abnormal lid position 14 cases (5%). 6 patients keratitis in a graft (2%), 3 had refractive surgery (1%). The most common causative organism isolated was pseudomonas aeroginosa (54%) followed by streptococcus 12%, staph 10%, other organisms 6%. 95% of contact lens wearers had pseudomonas Aeroginosa. This was statistically significant (p< 0.0001). The vast majority, 92% healed with scarring. 1% needed therapeutic keratoplasty and 7% lost to follow up. Risk factors in contact lens wearers were; 41 patients (36%) slept with the contact lenses. 12 (8%) had contact lens related trauma and 8 (7%) had poor hygiene. Sleeping with the contact lenses was statistically significant (p< 0.0001). Conclusion & Recommendation: Contact lens wear is the major risk factor for microbial keratitis in Bahrain. Pseudomonas aeroginosa was the commonest bacteria isolated. Sleeping with the contact lenses is the major risk factor among contact lens wearers. Majority of keratitis patients resulted in permanent scarring on the cornea. Educating the public, especially on contact lens care and precaution, can help reduce this visual morbidity. PMID:20142952

  13. Multiplane optical microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Tongcang; Ota, Sadao; Kim, Jeongmin

    This disclosure provides systems, methods, and apparatus related to optical microscopy. In one aspect, an apparatus includes a sample holder, a first objective lens, a plurality of optical components, a second objective lens, and a mirror. The apparatus may directly image a cross-section of a sample oblique to or parallel to the optical axis of the first objective lens, without scanning.

  14. Lens system for a photo ion spectrometer

    DOEpatents

    Gruen, D.M.; Young, C.E.; Pellin, M.J.

    1990-11-27

    A lens system in a photo ion spectrometer for manipulating a primary ion beam and ionized atomic component is disclosed. The atomic components are removed from a sample by a primary ion beam using the lens system, and the ions are extracted for analysis. The lens system further includes ionization resistant coatings for protecting the lens system. 8 figs.

  15. Land-use change and managed aquifer recharge effects on the hydrogeochemistry of two contrasting atoll island aquifers, Roi-Namur Island, Republic of the Marshall Islands

    USGS Publications Warehouse

    Hejazian, Mehrdad; Gurdak, Jason J.; Swarzenski, Peter W.; Odigie, Kingsley; Storlazzi, Curt

    2017-01-01

    Freshwater resources on low-lying atoll islands are highly vulnerable to climate change and sea-level rise. In addition to rainwater catchment, groundwater in the freshwater lens is a critically important water resource on many atoll islands, especially during drought. Although many atolls have high annual rainfall rates, dense natural vegetation and high evapotranspiration rates can limit recharge to the freshwater lens. Here we evaluate the effects of land-use/land-cover change and managed aquifer recharge on the hydrogeochemistry and supply of groundwater on Roi-Namur Island, Republic of the Marshall Islands. Roi-Namur is an artificially conjoined island that has similar hydrogeology on the Roi and Namur lobes, but has contrasting land-use/land-cover and managed aquifer recharge only on Roi. Vegetation removal and managed aquifer recharge operations have resulted in an estimated 8.6 x 105 m3 of potable groundwater in the freshwater lens on Roi, compared to only 1.6 x 104 m3 on Namur. We use groundwater samples from a suite of 33 vertically nested monitoring wells, statistical testing, and geochemical modeling using PHREEQC to show that the differences in land-use/land-cover and managed aquifer recharge on Roi and Namur have a statistically significant effect on several groundwater-quality parameters and the controlling geochemical processes. Results also indicate a seven-fold reduction in the dissolution of carbonate rock in the freshwater lens and overlying vadose zone of Roi compared to Namur. Mixing of seawater and the freshwater lens is a more dominant hydrogeochemical process on Roi because of the greater recharge and flushing of the aquifer with freshwater as compared to Namur. In contrast, equilibrium processes and dissolution-precipitation non-equilibrium reactions are more dominant on Namur because of the longer residence times relative to the rate of geochemical reactions. Findings from Roi-Namur Island support selective land-use/land-cover change and managed aquifer recharge as a promising management approach for communities on other low-lying atoll islands to increase the resilience of their groundwater supplies and help them adapt to future climate change related stresses.

  16. SPACE WARPS- II. New gravitational lens candidates from the CFHTLS discovered through citizen science

    NASA Astrophysics Data System (ADS)

    More, Anupreeta; Verma, Aprajita; Marshall, Philip J.; More, Surhud; Baeten, Elisabeth; Wilcox, Julianne; Macmillan, Christine; Cornen, Claude; Kapadia, Amit; Parrish, Michael; Snyder, Chris; Davis, Christopher P.; Gavazzi, Raphael; Lintott, Chris J.; Simpson, Robert; Miller, David; Smith, Arfon M.; Paget, Edward; Saha, Prasenjit; Küng, Rafael; Collett, Thomas E.

    2016-01-01

    We report the discovery of 29 promising (and 59 total) new lens candidates from the Canada-France-Hawaii Telescope Legacy Survey (CFHTLS) based on about 11 million classifications performed by citizen scientists as part of the first SPACE WARPS lens search. The goal of the blind lens search was to identify lens candidates missed by robots (the RINGFINDER on galaxy scales and ARCFINDER on group/cluster scales) which had been previously used to mine the CFHTLS for lenses. We compare some properties of the samples detected by these algorithms to the SPACE WARPS sample and find them to be broadly similar. The image separation distribution calculated from the SPACE WARPS sample shows that previous constraints on the average density profile of lens galaxies are robust. SPACE WARPS recovers about 65 per cent of known lenses, while the new candidates show a richer variety compared to those found by the two robots. This detection rate could be increased to 80 per cent by only using classifications performed by expert volunteers (albeit at the cost of a lower purity), indicating that the training and performance calibration of the citizen scientists is very important for the success of SPACE WARPS. In this work we present the SIMCT pipeline, used for generating in situ a sample of realistic simulated lensed images. This training sample, along with the false positives identified during the search, has a legacy value for testing future lens-finding algorithms. We make the pipeline and the training set publicly available.

  17. Lens capsule structure assessed with atomic force microscopy

    PubMed Central

    Sueiras, Vivian M.; Moy, Vincent T.

    2015-01-01

    Purpose To image the ultrastructure of the anterior lens capsule at the nanoscale level using atomic force microscopy (AFM). Methods Experiments were performed on anterior lens capsules maintained in their in situ location surrounding the lens from six human cadavers (donor age range: 44–88 years), four cynomolgus monkeys (Macaca fascicularis age range: 4.83–8.92 years), and seven pigs (<6 months). Hydration of all samples was maintained using Dulbecco’s Modified Eagle Medium (DMEM). Whole lenses were removed from the eye and placed anterior side up in agarose gel before gel hardening where only the posterior half of the lens was contained within the gel. After the gel hardened, the Petri dish was filled with DMEM until the point where the intact lens was fully submerged. AFM was used to image the anterior lens surface in contact mode. An integrated analysis program was used to calculate the interfibrillar spacing, fiber diameter, and surface roughness of the samples. Results The AFM images depict a highly ordered fibrous structure at the surface of the lens capsule in all three species. The interfibrillar spacing for the porcine, cynomolgus monkey, and human lens capsules was 0.68±0.25, 1.80±0.39, and 1.08±0.25 μm, respectively. In the primate, interfibrillar spacing significantly decreased linearly as a function of age. The fiber diameters ranged from 50 to 950 nm. Comparison of the root mean square (RMS) and average deviation demonstrate that the surface of the porcine lens capsule is the smoothest, and that the human and cynomolgus monkey capsules are significantly rougher. Conclusions AFM was successful in providing high-resolution images of the nanostructure of the lens capsule samples. Species-dependent differences were observed in the overall structure and surface roughness. PMID:25814829

  18. Multicenter study of optical low-coherence interferometry and partial-coherence interferometry optical biometers with patients from the United States and China.

    PubMed

    Hoffer, Kenneth J; Shammas, H John; Savini, Giacomo; Huang, Jinhai

    2016-01-01

    To evaluate the agreement between the measurements provided by a new optical biometer, the Aladdin, based on optical low-coherence interferometry (OLCI), and those provided by the most commonly used optical biometer (IOLMaster 500), based on partial-coherence interferometry (PCI). Multicenter clinical trial. Prospective evaluation of diagnostic test. In this study, 2 samples of adult patients were enrolled, 1 in the United States and the other in China. The U.S. group included a sample of consecutive patients scheduled for cataract surgery. The China group included a sample of healthy subjects with no cataracts. In both cases, only 1 eye of each patient was analyzed. Axial length (AL), corneal power (in diopters [D]) (K), anterior chamber depth (ACD) (corneal epithelium to lens), and corneal astigmatism were measured. All values were analyzed using a paired t test, the Pearson product-moment correlation coefficient (r), and Bland-Altman plots. In the U.S. and China groups, the OLCI mean AL values did not show a statistically significant difference from PCI values and showed excellent agreement and correlation. On the contrary, OLCI measured a lower mean K (-0.14 D) and a deeper ACD measurements (U.S. +0.16 mm and China +0.05 mm). These differences were statistically significant (P < .0001). Vector analysis did not show a statistically significant difference in astigmatism measurements. Agreement between OLCI and PCI was good. However, the small but statistically significant differences in K and ACD measurements make constant optimization necessary when calculating the intraocular lens power using theoretical formulas. Dr. Hoffer licenses the registered trademark name Hoffer to Carl Zeiss-Meditec (PCI), Haag-Streit (Lenstar), Movu (Argos), Oculus (Pentacam, AXL), Nidek (AL-Scan), Tomey (OA-2000), Topcon EU Visia Imaging (Aladdin), Ziemer (Galilei G6), and all A-scan biometer manufacturers. Dr. Shammas licenses his formulas to Carl Zeiss-Meditec (PCI), Haag-Streit (Lenstar), Nidek (AL-Scan), and Topcon EU (Visia Imaging) (Aladdin). None of the other authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Light absorption cell combining variable path and length pump

    DOEpatents

    Prather, William S.

    1993-01-01

    A device for use in making spectrophotometric measurements of fluid samples. In particular, the device is a measurement cell containing a movable and a fixed lens with a sample of the fluid therebetween and through which light shines. The cell is connected to a source of light and a spectrophotometer via optic fibers. Movement of the lens varies the path length and also pumps the fluid into and out of the cell. Unidirectional inlet and exit valves cooperate with the movable lens to assure a one-way flow of fluid through the cell. A linear stepper motor controls the movement of the lens and cycles it from a first position closer to the fixed lens and a second position farther from the fixed lens, preferably at least 10 times per minute for a nearly continuous stream of absorption spectrum data.

  20. [Risk of deterministic effects after exposure to low doses of ionizing radiation: retrospective study among health workers in view of a new publication of International Commission on Radiological Protection].

    PubMed

    Negrone, Mario; Di Lascio, Doriana

    2016-01-01

    The new recommended equivalent (publication n. 118 of International Commission on Radiological Protection) dose limit for occupational exposure of the lens of the eye is based on prevention of radiogenic cataracts, with the underlying assumption of a nominal threshold which has been adjusted from 2,5 Gy to 0.5 Gy for acute or protracted exposure. The study aim was to determine the prevalence of ocular lens opacity among healthcare workers (radiologic technologists, physicians, physician assistants) with respect to occupational exposures to ionizing radiations. Therefore, we conducted another retrospective study to explore the relationship between occupational exposure to radiation and opacity lens increase. Healthcare data (current occupational dosimetry, occupational history) are used to investigate risk of increase of opacity lens of eye. The sample of this study consisted of 148 health-workers (64 M and 84 W) aged from 28 to 66 years coming from different hospitals of the ASL of Potenza (clinic, hospital and institute with scientific feature). On the basis of the evaluation of the dosimetric history of the workers (global and effective dose) we agreed to ascribe the group of exposed subjects in cat A (equivalent dose > 2 mSV) and the group of non exposed subjects in cat B (workers with annual absorbed level of dose near 0 mSv). The analisys was conducted using SPSS 15.0 (Statistical Package for Social Science). A trend of increased ocular lens opacity was found with increasing number for workers in highest category of exposure (cat. A, Yates' chi-squared test = 13,7 p = 0,0002); variable significantly related to opacity lens results job: nurse (Χ(2)Y = 14,3 p = 0,0002) physician (Χ(2)Y = 2.2 p = 0,1360) and radiologic technologists (Χ(2)Y = 0,1 p = 0,6691). In conclusion our provides evidence that exposure to relatively low doses of ionizing radiation may be harmful to the lens of the eye and may increase a long-term risk of cataract formation; similary necessary to monitor the "equivalent dose" for the lens for the workers in highest category of exposure.

  1. Plural output optimetric sample cell and analysis system

    NASA Technical Reports Server (NTRS)

    Haley, F. C. (Inventor)

    1971-01-01

    An apparatus suitable for receiving a sample for optimetric analysis includes a sample cell comprising an opaque hollow tube. Several apertures are defined in the wall of the tubing and a lens barrel which extends beyond to opposite surfaces of the wall is supported within at least one of the apertures. A housing is provided with one channel for receiving the sample cell and a series of channels extending from the exterior housing to the sample cell apertures. A filter element is housed in each of these latter channels. These channels slidingly receive an excitation light source for a photodetector cell to permit selective focusing. A sample cell containing at least three apertures in the walls can be mounted for rotation relative to a light source or photoconduction means for simultaneous or alternative optimetric determination of the components of a single sample. The sample cell is fabricated by supporting a lens barrel within the aperture. A molten portion of glass is deposited in the lens barrel and cooled while in a horizontal position to form a lens having an acceptable angle.

  2. Corneal and crystalline lens dimensions before and after myopia onset.

    PubMed

    Mutti, Donald O; Mitchell, G Lynn; Sinnott, Loraine T; Jones-Jordan, Lisa A; Moeschberger, Melvin L; Cotter, Susan A; Kleinstein, Robert N; Manny, Ruth E; Twelker, J Daniel; Zadnik, Karla

    2012-03-01

    To describe corneal and crystalline lens dimensions before, during, and after myopia onset compared with age-matched emmetropic values. Subjects were 732 children aged 6 to 14 years who became myopic and 596 emmetropic children participating between 1989 and 2007 in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error Study. Refractive error was measured using cycloplegic autorefraction, corneal power using a hand-held autokeratometer, crystalline lens parameters using video-based phakometry, and vitreous chamber depth (VCD) using A-scan ultrasonography. Corneal and crystalline lens parameters in children who became myopic were compared with age-, gender-, and ethnicity-matched model estimates of emmetrope values annually from 5 years before through 5 years after the onset of myopia. The comparison was made without and then with statistical adjustment of emmetrope component values to compensate for the effects of longer VCDs in children who became myopic. Before myopia onset, the crystalline lens thinned, flattened, and lost power at similar rates for emmetropes and children who became myopic. The crystalline lens stopped thinning, flattening, and losing power within ±1 year of onset in children who became myopic compared with emmetropes statistically adjusted to match the longer VCDs of children who became myopic. In contrast, the cornea was only slightly steeper in children who became myopic compared with emmetropes (<0.25 D) and underwent little change across visits. Myopia onset is characterized by an abrupt loss of compensatory changes in the crystalline lens that continue in emmetropes throughout childhood axial elongation. The mechanism responsible for this decoupling remains speculative but might include restricted equatorial growth from internal mechanical factors.

  3. Light absorption cell combining variable path and length pump

    DOEpatents

    Prather, W.S.

    1993-12-07

    A device is described for use in making spectrophotometric measurements of fluid samples. In particular, the device is a measurement cell containing a movable and a fixed lens with a sample of the fluid there between and through which light shines. The cell is connected to a source of light and a spectrophotometer via optic fibers. Movement of the lens varies the path length and also pumps the fluid into and out of the cell. Unidirectional inlet and exit valves cooperate with the movable lens to assure a one-way flow of fluid through the cell. A linear stepper motor controls the movement of the lens and cycles it from a first position closer to the fixed lens and a second position farther from the fixed lens, preferably at least 10 times per minute for a nearly continuous stream of absorption spectrum data. 2 figures.

  4. Comparison of Accuracy in Intraocular Lens Power Calculation by Measuring Axial Length with Immersion Ultrasound Biometry and Partial Coherence Interferometry.

    PubMed

    Ruangsetakit, Varee

    2015-11-01

    To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.

  5. The Sloan Lens ACS Survey. XIII. Discovery of 40 New Galaxy-scale Strong Lenses

    NASA Astrophysics Data System (ADS)

    Shu, Yiping; Brownstein, Joel R.; Bolton, Adam S.; Koopmans, Léon V. E.; Treu, Tommaso; Montero-Dorta, Antonio D.; Auger, Matthew W.; Czoske, Oliver; Gavazzi, Raphaël; Marshall, Philip J.; Moustakas, Leonidas A.

    2017-12-01

    We present the full sample of 118 galaxy-scale strong-lens candidates in the Sloan Lens ACS (SLACS) Survey for the Masses (S4TM) Survey, which are spectroscopically selected from the final data release of the Sloan Digital Sky Survey. Follow-up Hubble Space Telescope (HST) imaging observations confirm that 40 candidates are definite strong lenses with multiple lensed images. The foreground-lens galaxies are found to be early-type galaxies (ETGs) at redshifts 0.06–0.44, and background sources are emission-line galaxies at redshifts 0.22–1.29. As an extension of the SLACS Survey, the S4TM Survey is the first attempt to preferentially search for strong-lens systems with relatively lower lens masses than those in the pre-existing strong-lens samples. By fitting HST data with a singular isothermal ellipsoid model, we find that the total projected mass within the Einstein radius of the S4TM strong-lens sample ranges from 3 × 1010 M ⊙ to 2 × 1011 M ⊙. In Shu et al., we have derived the total stellar mass of the S4TM lenses to be 5 × 1010 M ⊙ to 1 × 1012 M ⊙. Both the total enclosed mass and stellar mass of the S4TM lenses are on average almost a factor of 2 smaller than those of the SLACS lenses, which also represent the typical mass scales of the current strong-lens samples. The extended mass coverage provided by the S4TM sample can enable a direct test, with the aid of strong lensing, for transitions in scaling relations, kinematic properties, mass structure, and dark-matter content trends of ETGs at intermediate-mass scales as noted in previous studies. Based on observations made with the NASA/ESA Hubble Space Telescope (HST), obtained at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555. These observations are associated with HST program #12210.

  6. Acanthamoeba keratitis in Scotland: risk factors for contact lens wearers.

    PubMed

    Seal, D V; Kirkness, C M; Bennett, H G; Peterson, M

    1999-01-01

    To investigate risk factors for Acanthamoeba keratitis amongst contact lens wearers in Scotland. Patients with Acanthamoeba keratitis in the Scottish study, all of whom wore contact lenses, were compared with 46 healthy asymptomatic contact lens-wearing controls. They were all visited at home for contact lens and environmental microbiological sampling. In addition, all 288 optical practices in the West of Scotland were polled for contact lens types and disinfecting solutions sold in 1995, and a sample, each of whom fitted more than 500 contact lenses per year, were polled for a second time. Independently, a poll was commissioned by the Eyecare Information Service in July/August 1995 to estimate the numbers of contact lens wearers in Scotland and the UK. Industry was polled for numbers of each contact lens disinfecting regimen sold in Scotland in 1995. West of Scotland, UK. All contact lens wearers among the 3 million population of the West of Scotland Health Board Areas. Risk factors for Acanthamoeba infection and recommendations for its prevention. When Acanthamoeba infection occurred, patients' home water systems were frequently (54%) found to be colonised by this amoeba. Patients more frequently washed their storage cases in tap water than controls (P<0.05) with resulting contamination, kept storage cases wet rather than air drying them (P<0.05), and had coliform bacteria cultured from the storage case (P<0.05) and had viable Acanthamoeba within the storage case (P<0.0001). Overall, patients were found to have significantly more risk factors than controls (P<0.0001). The noncompliant use of chlorine tablet disinfection, or failure to disinfect contact lenses at all, was associated with increased risk (P<0.05). Ionic high water content contact lenses (FDA group 4 material), when used without disinfection or with non-compliant use of low chlorine (Soflab) tablet-based disinfection, were associated with increased risk of Acanthamoeba infection (P<0.05). In log-linear modelling of risky hygiene behaviours associated with contamination of storage cases with Acanthamoeba, the most significant behaviour was found to be use of the less effective disinfection methods (chlorine tablets or no disinfection). However further investigation showed that these methods were associated with an increased probability of rinsing the storage case in tap water, so that these two behaviours are confounded in the group studied. Failure to disinfect contact lenses, non-compliant use of chlorine tablets and/or introduction of tap water rinsing of storage cases were associated with increased risk of Acanthamoeba infection. New multipurpose solutions and hydrogen peroxide gave the lowest risk of Acanthamoeba infection, with no statistically significant difference between them. Ionic high-water content (FDA group 4) contact lenses were at increased risk of being associated with Acanthamoeba keratitis if used without effective disinfection (multipurpose solutions or hydrogen peroxide). The use of domestic tap water for contact lens and storage case hygiene must be avoided, as a chain-of-causation' was identified from the home water supply.

  7. Rose-K versus Soper contact lens in keratoconus: a randomized comparative trial.

    PubMed

    Gupta, Raghav; Sinha, Rajesh; Singh, Pooja; Sharma, Namrata; Tandon, Radhika; Titiyal, Jeewan S

    2014-01-01

    To perform a comparative evaluation of the efficacy and acceptability of Rose-K and Soper contact lenses in Keratoconus. Dr. Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. A randomized comparative clinical trial was performed in keratoconic eyes fitted with Rose-K (Rose-K group) and Soper (Soper group) contact lenses. Patients data were evaluated for best spectacle corrected visual acuity, best contact lens corrected visual acuity (BCLCVA), corneal topography, glare acuity, contrast sensitivity, tear function tests and specular microscopy. Patients were also asked to complete a self-reported comfort questionnaire at each visit. Sixty eyes were randomized to the Rose-K and Soper groups. The two groups were comparable in all the baseline parameters. There was a statistically significant improvement in BCLCVA in both groups at 3 months (P < 0.01, both groups). The difference between in BCLCVA in both groups was not statistically significant. In both groups, there was a significant improvement in the comfort score at 3 months compared to baseline (P < 0.05, both group). The Rose-K group had statistically significantly better scores at 1 and 3 months compared with the Soper group (P = 0.006 and P < 0.001 respectively). Both groups were associated with a significant (P < 0.01), but comparable improvement in glare acuity at 3 months. There was a significant improvement in contrast sensitivity at 3 months in both groups (P < 0.01); the Rose-K group was significantly better than the Soper group at 1 and 3 months (P = 0.001 and 0.002 respectively). The mean number of trial lenses required for fitting Rose-K lens (2.00 ± 0.59) was significantly lower than the Soper lens (3.43 ± 0.82; P < 0.001). Both the contact lens designs provide an equal improvement in visual acuity in patients with Keratoconus. However, Rose-K contact lens provides greater comfort, better quality of vision and requires less chair time compared with the Soper lens and hence may possibly have a greater acceptability.

  8. OCT-based crystalline lens topography in accommodating eyes.

    PubMed

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-12-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3 (-1)) and oblique trefoil (Z3 (-3)) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg).

  9. OCT-based crystalline lens topography in accommodating eyes

    PubMed Central

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-01-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3−1) and oblique trefoil (Z3−3) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg). PMID:26713216

  10. Peripheral optics with bifocal soft and corneal reshaping contact lenses.

    PubMed

    Ticak, Anita; Walline, Jeffrey J

    2013-01-01

    To determine whether bifocal soft contact lenses with a distance center design provide myopic defocus to the peripheral retina similar to corneal reshaping contact lenses. Myopic subjects underwent five cycloplegic autorefraction readings centrally and at 10, 20, and 30 degrees temporally, nasally, superiorly, and inferiorly while wearing Proclear Multifocal "D" contact lenses with a +2.00-diopter add power (CooperVision, Fairport, NY) and after wearing Corneal Refractive Therapy (Paragon Vision Sciences, Mesa, AZ) contact lenses for 2 weeks. Fourteen subjects completed the study. Nine (64%) were female, and 12 (86%) were white. The average (± SD) spherical equivalent noncycloplegic manifest refraction for the right eye was -2.84 ± 1.29 diopters. The average logMAR best-corrected, binocular, high-contrast visual acuity was -0.17 ± 0.15 while wearing the bifocal soft contact lenses and -0.09 ± 0.16 after corneal reshaping contact lens wear (analysis of variance, p = 0.27). The orthokeratology contact lens yielded a more myopic peripheral optical profile than the soft bifocal contact lens at 20 and 30 degrees eccentricity (except inferior at 20 degrees); the two modalities were similar at 10 degrees eccentricity. Our data suggest that the two modalities are dissimilar despite the statistical similarities. The corneal reshaping contact lens shows an increase in relative peripheral myopic refraction, a pattern achieved by other studies, but the bifocal lens does not exhibit such a pattern. The low statistical power of the study could be a reason for lack of providing statistical difference in other positions of gaze, but the graphical representation of the data shows a marked difference in the peripheral optical profile between the two modalities. More sophisticated methods of measuring the peripheral optical profile may be necessary to accurately compare the two modalities and to determine the true optical effect of the bifocal soft contact lens on the peripheral retina.

  11. Wide-field computational imaging of pathology slides using lens-free on-chip microscopy.

    PubMed

    Greenbaum, Alon; Zhang, Yibo; Feizi, Alborz; Chung, Ping-Luen; Luo, Wei; Kandukuri, Shivani R; Ozcan, Aydogan

    2014-12-17

    Optical examination of microscale features in pathology slides is one of the gold standards to diagnose disease. However, the use of conventional light microscopes is partially limited owing to their relatively high cost, bulkiness of lens-based optics, small field of view (FOV), and requirements for lateral scanning and three-dimensional (3D) focus adjustment. We illustrate the performance of a computational lens-free, holographic on-chip microscope that uses the transport-of-intensity equation, multi-height iterative phase retrieval, and rotational field transformations to perform wide-FOV imaging of pathology samples with comparable image quality to a traditional transmission lens-based microscope. The holographically reconstructed image can be digitally focused at any depth within the object FOV (after image capture) without the need for mechanical focus adjustment and is also digitally corrected for artifacts arising from uncontrolled tilting and height variations between the sample and sensor planes. Using this lens-free on-chip microscope, we successfully imaged invasive carcinoma cells within human breast sections, Papanicolaou smears revealing a high-grade squamous intraepithelial lesion, and sickle cell anemia blood smears over a FOV of 20.5 mm(2). The resulting wide-field lens-free images had sufficient image resolution and contrast for clinical evaluation, as demonstrated by a pathologist's blinded diagnosis of breast cancer tissue samples, achieving an overall accuracy of ~99%. By providing high-resolution images of large-area pathology samples with 3D digital focus adjustment, lens-free on-chip microscopy can be useful in resource-limited and point-of-care settings. Copyright © 2014, American Association for the Advancement of Science.

  12. Colonization of hydrogel lenses with Streptococcus pneumoniae: risk of development of corneal infiltrates.

    PubMed

    Sankaridurg, P R; Sharma, S; Willcox, M; Sweeney, D F; Naduvilath, T J; Holden, B A; Rao, G N

    1999-05-01

    To report the association between colonization of contact lenses with Streptococcus pneumoniae and the observation of corneal infiltrative events in a group of patients wearing disposable hydrogel lenses on an extended-wear schedule. In a prospective clinical trial, 330 patients wore disposable hydrogels on a 6-night extended-wear and replacement schedule. The contact lens, lid, and conjunctival microbiota of these subjects was analyzed at frequent intervals and at the time of an adverse event. Streptococcus pneumoniae was an uncommon isolate and was recovered from only one of the 3,763 conjunctival samples, five (0.1%) of the 3,764 lid samples, and 33 (0.8%) of the 4,315 contact lens samples. Of the 33 lens samples, 10 (30%) were associated with corneal infiltrative events. Many of the events were mild inflammatory responses and resolved rapidly on discontinuation of lens wear. The presence of S. pneumoniae on the contact lens was associated with a significant risk of development of corneal infiltrates (odds ratio, 3.0; p = 0.0227, logistic-regression analysis). Presence of S. pneumoniae on hydrogel lenses is a significant risk factor for the development of corneal infiltrates.

  13. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    PubMed

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  14. Corneal and Crystalline Lens Dimensions Before and After Myopia Onset

    PubMed Central

    Mutti, Donald O.; Mitchell, G. Lynn; Sinnott, Loraine T.; Jones-Jordan, Lisa A.; Moeschberger, Melvin L.; Cotter, Susan A.; Kleinstein, Robert N.; Manny, Ruth E.; Twelker, J. Daniel; Zadnik, Karla

    2011-01-01

    Purpose To describe corneal and crystalline lens dimensions before, during, and after myopia onset compared to age-matched emmetropic values. Methods Subjects were 732 children 6 to 14 years of age who became myopic and 596 emmetropic children participating between 1989 and 2007 in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error Study. Refractive error was measured using cycloplegic autorefraction, corneal power using a hand-held autokeratometer, crystalline lens parameters using video-based phakometry, and vitreous chamber depth (VCD) using A-scan ultrasonography. Corneal and crystalline lens parameters in children who became myopic were compared to age-, gender-, and ethnicity-matched model estimates of emmetrope values annually from 5 years before through 5 years after the onset of myopia. The comparison was made without, then with statistical adjustment of emmetrope component values to compensate for the effects of longer VCDs in children who became myopic. Results Before myopia onset, the crystalline lens thinned, flattened, and lost power at similar rates for emmetropes and children who became myopic. The crystalline lens stopped thinning, flattening, and losing power within ±1 year of onset in children who became myopic compared to emmetropes statistically adjusted to match the longer vitreous chamber depths of children who became myopic. In contrast, the cornea was only slightly steeper in children who became myopic compared to emmetropes (<0.25 D) and underwent little change across visits. Conclusions Myopia onset is characterized by an abrupt loss of compensatory changes in the crystalline lens that continue in emmetropes throughout childhood axial elongation. The mechanism responsible for this decoupling remains speculative, but might include restricted equatorial growth from internal mechanical factors. PMID:22227914

  15. Entropic Imaging of Cataract Lens: An In Vitro Study

    PubMed Central

    Shung, K. Kirk; Tsui, Po-Hsiang; Fang, Jui; Ma, Hsiang-Yang; Wu, Shuicai; Lin, Chung-Chih

    2014-01-01

    Phacoemulsification is a common surgical method for treating advanced cataracts. Determining the optimal phacoemulsification energy depends on the hardness of the lens involved. Previous studies have shown that it is possible to evaluate lens hardness via ultrasound parametric imaging based on statistical models that require data to follow a specific distribution. To make the method more system-adaptive, nonmodel-based imaging approach may be necessary in the visualization of lens hardness. This study investigated the feasibility of applying an information theory derived parameter – Shannon entropy from ultrasound backscatter to quantify lens hardness. To determine the physical significance of entropy, we performed computer simulations to investigate the relationship between the signal-to-noise ratio (SNR) based on the Rayleigh distribution and Shannon entropy. Young's modulus was measured in porcine lenses, in which cataracts had been artificially induced by the immersion in formalin solution in vitro. A 35-MHz ultrasound transducer was used to scan the cataract lenses for entropy imaging. The results showed that the entropy is 4.8 when the backscatter data form a Rayleigh distribution corresponding to an SNR of 1.91. The Young's modulus of the lens increased from approximately 8 to 100 kPa when we increased the immersion time from 40 to 160 min (correlation coefficient r = 0.99). Furthermore, the results indicated that entropy imaging seemed to facilitate visualizing different degrees of lens hardening. The mean entropy value increased from 2.7 to 4.0 as the Young's modulus increased from 8 to 100 kPa (r = 0.85), suggesting that entropy imaging may have greater potential than that of conventional statistical parametric imaging in determining the optimal energy to apply during phacoemulsification. PMID:24760103

  16. Microbial flora of tears of orthokeratology patients, and microbial contamination of contact lenses and contact lens accessories.

    PubMed

    Boost, Maureen V; Cho, Pauline

    2005-06-01

    The purpose of this study is to determine if there are changes in the ocular flora of overnight orthokeratology (ortho-k) patients, and the levels of contamination of their lenses and lens accessories, and to correlate compliance with levels of contamination. Normal ocular flora of 41 subjects was determined twice before commencing ortho-k lens wear by culture of the lower conjunctiva. Further specimens were collected on six follow-up visits after beginning lens wear, as were samples from their lenses, cases, and suction holders. A questionnaire on lens care was administered after the fifth visit. Three subjects provided conjunctival samples yielding Staphylococcus aureus on one occasion before lens wear, one being positive for this organism after beginning lens wear. Of 38 subjects yielding no growth or only normal eye flora before use, 28 remained free of ocular pathogens after beginning lens wear. Only four subjects had positive cultures on more than one occasion after lens wear. There was no significant difference in isolation levels of pathogens with lens wear (p = 0.423). Lens culture of 54% of subjects yielded no growth or normal flora only; lenses of 16 subjects yielded potential pathogens, including three subjects contaminated on more than one occasion. Lens isolates did not match the organisms transiently colonizing the eye. Lens case, the most frequently contaminated item, was associated with lens contamination (p < 0.001), the same organism being isolated from both items in 11 subjects. Lens suction holder was less frequently contaminated. Neither lens case nor suction holder contamination was associated with isolates from the eye. Reported good compliance correlated with lack of contamination in all but one subject. The most frequent breaches in the lens care protocol were failure to clean, disinfect, and replace the lens case. Ocular flora was not altered by ortho-k lens wear over an extended period, and patients remained free of infection. Contaminants identified were generally of a transient nature. Most patients had significant contamination of at least one item, most frequently the lens case. Lens case isolates were significantly associated with those from the lens. The majority of patients reporting good compliance had low or no contamination of their lenses and accessories.

  17. Are Statisticians Cold-Blooded Bosses? A New Perspective on the "Old" Concept of Statistical Population

    ERIC Educational Resources Information Center

    Lu, Yonggang; Henning, Kevin S. S.

    2013-01-01

    Spurred by recent writings regarding statistical pragmatism, we propose a simple, practical approach to introducing students to a new style of statistical thinking that models nature through the lens of data-generating processes, not populations. (Contains 5 figures.)

  18. Refractive lens exchange in younger and older presbyopes: comparison of complication rates, 3 months clinical and patient-reported outcomes

    PubMed Central

    Schallhorn, Steven C; Schallhorn, Julie M; Pelouskova, Martina; Venter, Jan A; Hettinger, Keith A; Hannan, Stephen J; Teenan, David

    2017-01-01

    Purpose To compare refractive and visual outcomes, patient satisfaction, and complication rates among different age categories of patients who underwent refractive lens exchange (RLE). Methods A stratified, simple random sample of patients matched on preoperative sphere and cylinder was selected for four age categories: 45–49 years (group A), 50–54 years (group B), 55–59 years (group C), and 60–65 years (group D). Each group contained 320 patients. All patients underwent RLE with a multifocal intraocular lens at least in one eye. Three months postoperative refractive/visual and patient-reported outcomes are presented. Results The percentage of patients that achieved binocular uncorrected distance visual acuity 20/20 or better was 91.6% (group A), 93.8% (group B), 91.6% (group C), 88.8% (group D), P=0.16. Binocularly, 80.0% of patients in group A, 84.7% in group B, 78.9% in group C, and 77.8% in group D achieved 20/30 or better uncorrected near visual acuity (P=0.13). The proportion of eyes within 0.50 D of emmetropia was 84.4% in group A, 86.8% in group B, 85.7% in group C, and 85.8% in group D (P=0.67). There was no statistically significant difference in postoperative satisfaction, visual phenomena, dry eye symptoms, distance or near vision activities. Apart from higher rate of iritis in the age group 50–55 years, there was no statistically significant difference in postoperative complication rates. Conclusion RLE can be safely performed in younger as well as older presbyopes. No significant difference was found in clinical or patient-reported outcomes. PMID:28894356

  19. WFIRST: Microlensing Parallax Observations from K2 in the Exoplanet Microlensing Field

    NASA Astrophysics Data System (ADS)

    Ranc, Clement; Radek Poleski, David Bennett, K2C9 Microlensing Science Experiment Team

    2018-01-01

    The recent explosion in our understanding of exoplanetary systems has been driven primarily by the Kepler mission, which has replaced radial velocities as our main planet discovery method. While Kepler has provided a large sample of planets that will allow a robust statistical determination of the properties of exoplanets in close orbits about their host stars, the Kepler mission was stopped shortly after the start of its 5th year. This led to the Kepler 2 (K2) mission, which could observe up to 18 different fields in the ecliptic plane, including a fraction of the WFIRST microlensing field. The K2 mission has focused on lower mass host stars and spending one observing campaign in the Galactic bulge to make use of Kepler’s orbit to determine the masses and distances to microlensing systems via the microlensing parallax effect. These K2 Campaign 9 observations help to develop the microlensing planet detection method, which will be employed by the WFIRST mission that will extend the statistical census of exoplanets to include low-mass planets in wide orbits. While the photometric light curve of a microlensing event observed from the ground provides important constraints on the lens physical parameters, in many cases the lens mass and distance from Earth remain degenerated. The poster will show how simultaneous space- and ground-based observations can break this mass-distance degeneracy. This method will be used for a fraction of the events observed by WFIRST. Finally, the poster will present a new method to correct the K2 photometry from the correlated systematic noise. This investigation helps in characterizing the properties of the lens stars and source stars in one WFIRST field with high extinction.

  20. Secondary optics for Fresnel lens solar concentrators

    NASA Astrophysics Data System (ADS)

    Fu, Ling; Leutz, Ralf; Annen, Hans Philipp

    2010-08-01

    Secondary optics are used in concentrating photovoltaic (CPV) systems with Fresnel lens primaries to increase the optical system efficiency by catching refracted light that otherwise would miss the receiver, better the tracking tolerance (acceptance half-angle) and enhance the flux uniformity on the cell. Several refractive secondary optics under the same Fresnel lens primary are designed, analyzed and compared based on their optical performances, materials, manufacturability, manufacturing tolerancing and cost. The goal of this work is to show the basic two different design approaches statistical mixing as opposed to deterministic mixing. Caustics are elementary in the deterministic tailoring approach. We find that statistical mixing offers higher flexibility for the solar application. It is also shown that there are conventional, i.e. designs based on conic section ("half-egg") that work well as solar secondaries. It is also made clear that primary and secondary must be designed as optical train.

  1. Through Your Lens: Student and Teacher Views of School Facilities across America

    ERIC Educational Resources Information Center

    21st Century School Fund, 2010

    2010-01-01

    "The Through Your Lens" book brings together the vivid photos and poignant stories of students and teachers across America with context from statistics, maps and background. It illustrates current school conditions, how our system reached this point, and what is possible for all students and teachers. Perhaps most important, it answers the…

  2. White light photothermal lens spectrophotometer for the determination of absorption in scattering samples.

    PubMed

    Marcano, Aristides; Alvarado, Salvador; Meng, Junwei; Caballero, Daniel; Moares, Ernesto Marín; Edziah, Raymond

    2014-01-01

    We developed a pump-probe photothermal lens spectrophotometer that uses a broadband arc-lamp and a set of interference filters to provide tunable, nearly monochromatic radiation between 370 and 730 nm as the pump light source. This light is focused onto an absorbing sample, generating a photothermal lens of millimeter dimensions. A highly collimated monochromatic probe light from a low-power He-Ne laser interrogates the generated lens, yielding a photothermal signal proportional to the absorption of light. We measure the absorption spectra of scattering dye solutions using the device. We show that the spectra are not affected by the presence of scattering, confirming that the method only measures the absorption of light that results in generation of heat. By comparing the photothermal spectra with the usual absorption spectra determined using commercial transmission spectrophotometers, we estimate the quantum yield of scattering of the sample. We discuss applications of the device for spectroscopic characterization of samples such as blood and gold nanoparticles that exhibit a complex behavior upon interaction with light.

  3. Effect of chronic smoking on lens nucleus as assessed by Pentacam HR lens densitometry in young adults.

    PubMed

    Pekel, Gökhan; Cetin, Ebru Nevin; Acer, Semra; Yagci, Ramazan; Altintas, Seher; Ongun, Gülin Tugba

    2014-06-01

    To evaluate the effects of chronic tobacco smoking on lens nucleus by Pentacam HR lens densitometry (LD) in young adults. Prospective cross-sectional case series. Thirty subjects (23 M, 7 F) who were chronic cigarette smokers (≥10 cigarettes/day for at least 2 years) (group 1) and another 30 subjects (23 M, 7 F) who did not smoke (group 2), were included in this study. The patients were matched for age and sex between the groups. The exclusion criteria were any history of ocular surgery, any systemic disorders and any ocular diseases except for mild refractive disorders. Lens densitometry measurements were done with the Pentacam HR (Oculus, Wetzlar, Germany). The Schirmer test and pachymetry measurements were also performed. Mean age of the patients for both groups was 28.90 ± 8.20 years (range: 18-40 years). Mean lens densitometry (LD) measurements of Group 1 (chronic cigarette smoking group) were higher than those of Group 2 (control group) in all LD techniques; however only mean "peak" LD measurements showed a statistically significant difference between these two groups (Group 1: 8.67 ± 0.61, Group 2: 8.44 ± 0.70, p = 0.04). The mean Schirmer test value was 12.43 ± 5.60 mm in Group 1 and 13.00 ± 4.26 mm in Group 2 (p = 0.55). The mean central corneal thickness (CCT) value was 564.23 ± 34.61 µm in Group 1 and 550.47 ± 32.94 µm in Group 2 (p = 0.03). The Pentacam HR LD seems to be an important option for the evaluation of lens nucleus in young adults, because it gives objective and quantitative data. Although chronic smoking increases lens nucleus density in young adults, the effect is not statistically significant when compared with the control group.

  4. Significant Statistics: Viewed with a Contextual Lens

    ERIC Educational Resources Information Center

    Tait-McCutcheon, Sandi

    2010-01-01

    This paper examines the pedagogical and organisational changes three lead teachers made to their statistics teaching and learning programs. The lead teachers posed the research question: What would the effect of contextually integrating statistical investigations and literacies into other curriculum areas be on student achievement? By finding the…

  5. Contact Lens-Induced Discomfort and Inflammatory Mediator Changes in Tears.

    PubMed

    Masoudi, Simin; Zhao, Zhenjun; Stapleton, Fiona; Willcox, Mark

    2017-01-01

    Studies indicate that contact lens (CL) discontinuation mostly occurs because of dryness and discomfort symptoms. This study aimed to investigate relationships between changes in the concentration of tear inflammatory mediators with subjective comfort ratings with CL wear and no contact lens wear between morning and evening. Forty-five subjects collected tears twice daily in the morning and in the evening with or without lenses. Comfort was rated subjectively on a scale from 1 to 100 (where 100 was extremely comfortable) just before each tear collection. Tear samples were assayed for complement components (C3 and C3a), leukotriene B4 (LTB4), secretory phospholipase A2 (sPLA2), secretory immunoglobulin A (sIgA), and bradykinin using commercially available immuno-based assay kits. Comfort ratings showed a statistically significant decline from morning to evening both with CL (89.0±10.1 AM vs. 76.7±15.2 PM; P<0.001) and without CL (89.1±10.2 AM vs. 84.2±12.6 PM; P<0.005) wear. The decline was steeper with lens wear (P<0.001). Bradykinin and sPLA2 levels did not change between morning and evening or with CL wear (P>0.05). Leukotriene B4 levels were slightly higher in CL (CL 43.4±12.6 pg/ml vs. No CL 39.4±13.4 pg/mL; P=0.034), whereas the concentration of LTB4, C3, C3a, and sIgA dropped by the end of the day in the presence or absence of lens wear (P<0.001). For most mediators, tear levels were not correlated with comfort ratings in any of the conditions. Leukotriene B4 had a higher concentration in the evening, and when measured as a ratio to sIgA, there was a trend for increased concentration of this mediator during CL wear. Although specific mediators showed changes from morning to evening with and without lens wear, most of these were not correlated with subjective comfort ratings in lens wear. The only mediator that showed an increase in concentration during the day and during lens wear was LTB4, and further studies on this mediator are warranted.

  6. Bacterial and fungal biofilm formation on contact lenses and their susceptibility to lens care solutions.

    PubMed

    Kackar, Siddharth; Suman, Ethel; Kotian, M Shashidhar

    2017-01-01

    Microbial biofilm formation on contact lenses and lens storage cases may be a risk factor for contact lens-associated corneal infections. Various types of contact lens care solutions are used to reduce microbial growths on lenses. The present study aimed at comparing the growths of biofilms on the different contact lenses and lens cases. The study also aimed at determining the effect of lens care solutions and bacteriophage on these biofilms. One type of hard lens and two types of soft lenses were used for the study. The organisms used were Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Candida albicans ATCC 60193 and Escherichia coli ATCC 25922. Biofilm production was performed by modified O'Toole and Kolter method and effect of lens cleaning solutions and a crude coliphage on biofilms was also studied. Results were visualised using scanning electron microscopy and quantitated by colony counting method and spectrophotometric measurement of optical density (OD). Statistical analysis was done by SPSS 11.5, Kruskal-Wallis test and Chi-square test. Soft lens cleaning solutions had a significant inhibitory effect (P = 0.020) on biofilm formation on soft lenses and also lens cases (P < 0.001). Soft lens cleaning solution 2 was more efficient than solution 1. However, no such inhibitory effect was observed with regard to hard lens cleaning solution, but for a significant reduction in the OD values (P < 0.001). There was no significant inhibitory effect by bacteriophages. This study showed the importance of selecting the appropriate lens cleaning solution to prevent biofilm production on contact lenses.

  7. The inner mass power spectrum of galaxies using strong gravitational lensing: beyond linear approximation

    NASA Astrophysics Data System (ADS)

    Chatterjee, Saikat; Koopmans, Léon V. E.

    2018-02-01

    In the last decade, the detection of individual massive dark matter sub-haloes has been possible using potential correction formalism in strong gravitational lens imaging. Here, we propose a statistical formalism to relate strong gravitational lens surface brightness anomalies to the lens potential fluctuations arising from dark matter distribution in the lens galaxy. We consider these fluctuations as a Gaussian random field in addition to the unperturbed smooth lens model. This is very similar to weak lensing formalism and we show that in this way we can measure the power spectrum of these perturbations to the potential. We test the method by applying it to simulated mock lenses of different geometries and by performing an MCMC analysis of the theoretical power spectra. This method can measure density fluctuations in early type galaxies on scales of 1-10 kpc at typical rms levels of a per cent, using a single lens system observed with the Hubble Space Telescope with typical signal-to-noise ratios obtained in a single orbit.

  8. Design of a novel system for spectroscopy measurements of the aqueous humor

    NASA Astrophysics Data System (ADS)

    Miller, Joe; Uttamchandani, Deepak G.

    2001-06-01

    The authors report on the design of a system which will enable real time measurements of (therapeutic) drug concentrations in the anterior chamber of the eye. Currently the concentration of therapeutic drugs in the anterior chamber is determined by analyzing samples which have been removed from the aqueous humor of laboratory animal eyes. This sampling via paracentesis can be painful and does not provide a continuous measurement. Our system will be far less invasive, removing the need for sampling via paracentesis, and also providing a continuous measurement, enabling a more complete understanding of the kinetics of ophthalmic drugs. A key component in our novel system is a specially constructed contact lens. We report on the design, optimization and manufacture of such a contact lens system capable of directing UV/VIS light in, across and out of the anterior chamber of the eye, thereby enabling absorption spectroscopy measurements of the aqueous humor to be undertaken. Design of the one piece contact lens/mirror system was achieved using the Zemax optical design software package and the lens was fabricated from synthetic fused silica. Results from modeling of the lens and experimental measurements on light propagation across the anterior chamber of animal eyes assisted by the lens will be reported.

  9. LENS: web-based lens for enrichment and network studies of human proteins

    PubMed Central

    2015-01-01

    Background Network analysis is a common approach for the study of genetic view of diseases and biological pathways. Typically, when a set of genes are identified to be of interest in relation to a disease, say through a genome wide association study (GWAS) or a different gene expression study, these genes are typically analyzed in the context of their protein-protein interaction (PPI) networks. Further analysis is carried out to compute the enrichment of known pathways and disease-associations in the network. Having tools for such analysis at the fingertips of biologists without the requirement for computer programming or curation of data would accelerate the characterization of genes of interest. Currently available tools do not integrate network and enrichment analysis and their visualizations, and most of them present results in formats not most conducive to human cognition. Results We developed the tool Lens for Enrichment and Network Studies of human proteins (LENS) that performs network and pathway and diseases enrichment analyses on genes of interest to users. The tool creates a visualization of the network, provides easy to read statistics on network connectivity, and displays Venn diagrams with statistical significance values of the network's association with drugs, diseases, pathways, and GWASs. We used the tool to analyze gene sets related to craniofacial development, autism, and schizophrenia. Conclusion LENS is a web-based tool that does not require and download or plugins to use. The tool is free and does not require login for use, and is available at http://severus.dbmi.pitt.edu/LENS. PMID:26680011

  10. [Are biometric parameters of anterior segment of the eyeball influenced by type 2 diabetes?].

    PubMed

    Dmuchowska, Diana A; Kraśnicki, Paweł; Mariak, Zofia

    2012-01-01

    To answer the question whether biometric parameters of anterior segment of the eyeball are influenced by type 2 diabetes, at the stage when the lens is still transparent, so before cataract development. Fifty subjects (28 women and 22 men), at the age of 63.3 +/- 11.3 years were enrolled in this prospective study. They were divided in 2 groups: patients with type 2 diabetes (24 subjects) and analogous age group in good general health - control group (26 subjects). None of the tested individuals presented lens opacities. The planned biometric measurements included: central corneal thickness, anterior chamber depth and axial lens thickness. The data were statistically analyzed. There was no difference between the groups of both proven and potential parameters that are associated with biometric measurements of the anterior segment of the eyeball, such as: gender, age, smoking and axial length of the eye. In diabetic patients, as opposed to the subjects in the control group, statistically significantly increased lens thickness (4.78 +/- 0.50 mm vs 4.43 +/- 0.50; p = 0.016), central corneal thickness (561.5 +/- 31.6 microm vs 542.2 +/- 35.2; p = 0.047), and the tendency for shallow anterior chamber (3.06 +/- 0.40 mm vs 3.22 +/- 0.38; p = 0.159), were observed. In patients with diabetes there was no association of the biometric parameters values with the duration of diabetes and presence of diabetic retinopathy. Type 2 diabetes contributes to increased axial corneal and lens thickness at the stage when the lens is transparent, albeit it does not significantly affect anterior chamber depth.

  11. The Application of Globular Water-Atomized Iron Powders for Additive Manufacturing by a LENS Technique.

    PubMed

    Durejko, Tomasz; Aniszewska, Justyna; Ziętala, Michał; Antolak-Dudka, Anna; Czujko, Tomasz; Varin, Robert A; Paserin, Vlad

    2018-05-18

    The water-atomized ATOMET 28, 1001, 4701, and 4801 powders, manufactured by Rio Tinto Metal Powders, were used for additive manufacturing by a laser engineered net shaping (LENS) technique. Their overall morphology was globular and rounded with a size distribution from about 20 to 200 µm. Only the ATOMET 28 powder was characterized by a strong inhomogeneity of particle size and irregular polyhedral shape of powder particles with sharp edges. The powders were pre-sieved to a size distribution from 40 to 150 µm before LENS processing. One particular sample-LENS-fabricated from the ATOMET 28 powder-was characterized by the largest cross-sectional (2D) porosity of 4.2% and bulk porosity of 3.9%, the latter determined by microtomography measurements. In contrast, the cross-sectional porosities of bulk, solid, nearly cubic LENS-fabricated samples from the other ATOMET powders exhibited very low porosities within the range 0.03⁻0.1%. Unexpectedly, the solid sample-LENS-fabricated from the reference, a purely spherical Fe 99.8 powder-exhibited a porosity of 1.1%, the second largest after that of the pre-sieved, nonspherical ATOMET 28 powder. Vibrations incorporated mechanically into the LENS powder feeding system substantially improved the flow rate vs. feeding rate dependence, making it completely linear with an excellent coefficient of fit, R² = 0.99. In comparison, the reference powder Fe 99.8 always exhibited a linear dependence of the powder flow rate vs. feeding rate, regardless of vibrations.

  12. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher

    PubMed Central

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-01-01

    Purpose To determine if the lens volume changes during accommodation. Methods The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. Results The mean (±SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were −0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Conclusions Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule. PMID:26161985

  13. RISK FACTORS FOR CONTACT LENS INDUCED PAPILLARY CONJUNCTIVITIS ASSOCIATED WITH SILICONE HYDROGEL CONTACT LENS WEAR

    PubMed Central

    Tagliaferri, Angela; Love, Thomas E.; Szczotka-Flynn, Loretta

    2014-01-01

    BACKGROUND Contact lens induced papillary conjunctivitis (CLPC) continues to be a major cause of dropout during contact lens extended wear. This retrospective study explores risk factors for the development of CLPC during silicone hydrogel lens extended wear. METHODS Data from 205 subjects enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens (LASH) study wearing lotrafilcon A silicone hydrogel lenses for up to 30 days of continuous wear were used to determine risk factors for CLPC in this secondary analysis of the main cohort. The main covariates of interest included substantial lens-associated bacterial bioburden, and topographically determined lens base curve-to-cornea fitting relationships. Additional covariates of interest included history of prior adverse events, time of year, race, education level, gender and other subject demographics. Statistical analyses included univariate logistic regression to assess the impact of potential risk factors on the binary CLPC outcome, and Cox proportional hazards regression to describe the impact of those factors on time-to-CLPC diagnosis. RESULTS Across 12 months of follow-up, 52 subjects (25%) experienced CLPC. No associations were found between CLPC development and the presence of bacterial bioburden, lens-to-cornea fitting relationships, history of prior adverse events, gender or race. CLPC development followed the same seasonal trends as the local peaks in environmental allergans. CONCLUSIONS Lens fit and biodeposits, in the form of lens associated bacterial bioburden, were not associated with the development of CLPC during extended wear with lotrafilcon A silicone hydrogel lenses. PMID:24681609

  14. Potential sources of bacteria that are isolated from contact lenses during wear.

    PubMed

    Willcox, M D; Power, K N; Stapleton, F; Leitch, C; Harmis, N; Sweeney, D F

    1997-12-01

    The aim of this paper was to determine the possible contamination sources of contact lenses during wear. Potential sources of the microbiota that colonized hydrogel contact lenses during wear were examined. The microorganisms that colonize contact lenses were grown, identified, and compared to those microorganisms that colonized the lower lid margins, upper bulbar conjunctiva, hands, and contact lens cases of contact lens wearers. In addition, the incidence of contamination of the domestic water supply in the Sydney area was obtained, and this was compared to the incidence of colonization of contact lenses by microorganisms in general and gram-negative bacteria in particular. There was a wide diversity of bacteria that were isolated from each site sampled. Coagulase-negative staphylococci and Propionibacterium spp. were the most common isolates from all ocular sites examined, and constituted the normal ocular microbiota. Other bacteria, including members of the families Enterobacteriaceae and Pseudomonadaceae, were isolated infrequently from all sites, but most frequently from contact lens cases. Statistical analysis revealed that there was a correlation between the isolation of bacteria from the contact lens and the lower lid margin (p < 0.001). Analysis of this correlation revealed that this was true for the normal microbiota. A correlation was also noted between the colonization of contact lenses by gram-negative bacteria and contamination of the domestic water supply. This study has demonstrated that the likely route for the normal ocular microbiota colonizing contact lenses is via the lid margins, whereas colonization by gram-negative bacteria, including potential agents of microbial keratitis, is likely to be from the domestic water supply.

  15. [UV-induced DNA damage and protective effects of antioxidants on DNA damage in human lens epithelial cells studied with comet assay].

    PubMed

    Wu, Zhi-hong; Wang, Mian-rong; Yan, Qi-chang; Pu, Wei; Zhang, Jin-song

    2006-11-01

    To investigate the mechanism of UV-induced DNA damage and repair and the protective effects of antioxidants on DNA damage in human lens epithelial cells. Human lens epithelial cells were irradiated at UV-doses 0.0 (control group), 2.5, 5.0, 7.5, 10.0 mJ/cm(2) (treated group 1 - 4). The amounts of DNA single strand breaks (SSB) were measured with the alkaline comet assay (CA). The spontaneous repair of DNA SSB after exposure to UV at 10.0 mJ/cm(2) was also determined in human lens epithelial cells. Human lens epithelial cells were treated with different concentration of VitaminC (VitC), taurine, superoxide dismutase (SOD) and epigallocatechin gallate (EGCG) before and after ultraviolet radiation, the effects of antioxidants on DNA damage was examined with alkaline comet assay. The amount of DNA SSB in control group and treated groups 1 - 4 showed increased tendency, was dose-dependent to the dose of UV irradiation, the differences of DNA SSB in 5 group were significantly (P < 0.01). UV-induced DNA SSB at 10.0 mJ/cm(2) in human lens epithelial cells, the half repair time was 60 minutes. Human lens epithelial cells were treated with different concentrations of taurine, SOD and EGCG before ultraviolet radiation. The differences of DNA damage in control and various antioxidant treated groups was statistically significant (F = 6.591, 13.542, 4.626 in cells treated with taurine, SOD and EGCG, respectively, P < 0.01), the difference of VitC effect on DNA in control and treated group were not significantly (F = 1.451, P > 0.05). Human lens epithelial cells were treated with different concentration of VitC, taurine, SOD and EGCG after ultraviolet radiation. The differences of DNA damage between the control and treated group were statistically significant (F = 6.571, 4.810, 6.824, 9.182 in cells treated with VitC, taurine, SOD and EGCG, respectively, P < 0.01). The differences of protective effects on DNA damage in these four different kinds of antioxidants added before UV irradiation were statistically significant (P < 0.01). The differences of protective effects on DNA damage in these four different kinds of antioxidant added after UV irradiation were not significantly (P > 0.05). UV irradiation has a dose-dependent effect on the DNA SSB of lens epithelial cells. Exogenesis VitC, taurine, SOD, EGCG possess protective effective to UV-induced DNA damage. SOD is one of the most powerful antioxidants if added before the UV irradiation and followed by EGCG, taurine and VitC orderly. Four kinds of antioxidants show no apparently differences added after UV-irradiation. SOD and EGCG both are powerful antioxidants.

  16. Lens-free imaging-based low-cost microsensor for in-line wear debris detection in lube oils

    NASA Astrophysics Data System (ADS)

    Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko

    2017-02-01

    The current paper describes the application of lens-free imaging principles for the detection and classification of wear debris in lubricant oils. The potential benefits brought by the lens-free microscopy techniques in terms of resolution, deep of field and active areas have been tailored to develop a micro sensor for the in-line monitoring of wear debris in oils used in lubricated or hydraulic machines as gearboxes, actuators, engines, etc. The current work presents a laboratory test-bench used for evaluating the optical performance of the lens-free approach applied to the wear particle detection in oil samples. Additionally, the current prototype sensor is presented, which integrates a LED light source, CMOS imager, embedded CPU, the measurement cell and the appropriate optical components for setting up the lens-free system. The imaging performance is quantified using micro structured samples, as well as by imaging real used lubricant oils. Probing a large volume with a decent 2D spatial resolution, this lens-free micro sensor can provide a powerful tool at very low cost for inline wear debris monitoring.

  17. Peripheral Defocus of the Monkey Crystalline Lens With Accommodation in a Lens Stretcher

    PubMed Central

    Maceo Heilman, Bianca; Manns, Fabrice; Ruggeri, Marco; Ho, Arthur; Gonzalez, Alex; Rowaan, Cor; Bernal, Andres; Arrieta, Esdras; Parel, Jean-Marie

    2018-01-01

    Purpose To characterize the peripheral defocus of the monkey crystalline lens and its changes with accommodation. Methods Experiments were performed on 15 lenses from 11 cynomolgus monkey eyes (age: 3.8–12.4 years, postmortem time: 33.5 ± 15.3 hours). The tissue was mounted in a motorized lens stretcher to allow for measurements of the lens in the accommodated (unstretched) and unaccommodated (stretched) states. A custom-built combined laser ray tracing and optical coherence tomography system was used to measure the paraxial on-axis and off-axis lens power for delivery angles ranging from −20° to +20° (in air). For each delivery angle, peripheral defocus was quantified as the difference between paraxial off-axis and on-axis power. The peripheral defocus of the lens was compared in the unstretched and stretched states. Results On average, the paraxial on-axis lens power was 52.0 ± 3.4 D in the unstretched state and 32.5 ± 5.1 D in the stretched state. In both states, the lens power increased with increasing delivery angle. From 0° to +20°, the relative peripheral lens power increased by 10.7 ± 1.4 D in the unstretched state and 7.5 ± 1.6 D in the stretched state. The change in field curvature with accommodation was statistically significant (P < 0.001), indicating that the unstretched (accommodated) lens has greater curvature or relative peripheral power. Conclusions The cynomolgus monkey lens has significant accommodation-dependent curvature of field, which suggests that the lens asserts a significant contribution to the peripheral optical performance of the eye that also varies with the state of accommodation.

  18. Constraints on early-type galaxy structure from spectroscopically selected gravitational lenses

    NASA Astrophysics Data System (ADS)

    Bolton, Adam Stallard

    2005-11-01

    This thesis describes all aspects of a unique spectroscopic survey for strong galaxy-galaxy gravitational lenses: motivation, candidate selection, ground- based spectroscopic follow-up, Hubble Space Telescope imaging, data analysis, and results on the radial density profile of the lens galaxies. The lens candidates are selected from within the spectroscopic database of the Sloan Digital Sky Survey (SDSS) based on the appearance of two significantly different redshifts along the same line of sight, and lenses are confirmed within the candidate sample by follow-up imaging and spectroscopy. The sample of [approximate]20 early-type lenses presented in this thesis represents the largest single strong-lens galaxy sample discovered and published to date. These lenses probe the mass of the lens galaxies on scales roughly equal to one-half effective radius. We find a dynamical normalization between isothermal lens-model velocity dispersions and aperture-corrected SDSS stellar velocity dispersions of f = s lens /s stars = 0.95 +/- 0.03. By combining lens-model Einstein radii and de Vaucouleurs effective radii with stellar velocity dispersions through the Jeans equation, we find that the logarithmic slope [Special characters omitted.] of the density profile in our lens galaxies (r 0 ( [Special characters omitted.] ) is on average slightly steeper than isothermal ([Special characters omitted.] = 2) with a modest intrinsic scatter. Parameterizing the intrinsic distribution in [Special characters omitted.] as Gaussian, we find a maximum-likelihood mean of [Special characters omitted. ] and standard deviation of s[Special characters omitted.] = [Special characters omitted.] (68% confidence, for isotropic velocity-dispersion models). Our results rule out a single universal logarithmic density slope at >99.995% confidence. The success of this spectroscopic lens survey suggests that similar projects should be considered as an explicit science goal of future redshift surveys. (Copies available exclusively from MIT Libraries, Rm. 14-0551, Cambridge, MA 02139-4307. Ph. 617-253-5668; Fax 617-253-1690.)

  19. Objective evaluation of the changes in the crystalline lens during accommodation in young and presbyopic populations using Pentacam HR system.

    PubMed

    Ni, Yao; Liu, Xia-Lin; Wu, Ming-Xing; Lin, Ying; Sun, Yu-Ying; He, Chang; Liu, Yi-Zhi

    2011-01-01

    To quantify the changes in the lens profile with accommodation in different age groups. The Pentacam HR system was used to obtain the images of the anterior eye segment from 23 young and 15 presbyopic emmetropic subjects in unaccommodated (with an accommodation stimulus of 0.0D) and accommodated (with an accommodation stimulus of 5.0D for the young group and 1.0D for the presbyopic group) states. The phakic crystalline lens shape, including curvature of crystalline lens and central lens thickness (CLT), and the measurements of anterior segment length (ASL), central anterior chamber depth (CACD) were investigated. The anterior chamber volume (ACV) was also measured. The reduction of CACD and ACV were significant in both groups after accommodation stimulus. From the profile of anterior eye segment, a significant decrease in anterior crystalline lens radii of curvature (-2.52mm) and a mean increase in CLT (0.222mm) and ASL (0.108mm) were found in the young group with an accommodation stimulus of 5.0D. However, no statistically significant changes of CLT, ASL, or crystalline lens radii of curvature were found in the presbyopic group. Our data showed that the shallowing of anterior chamber during accommodation was caused by the forward bulging of the anterior lens surface, rather than by anterior shifting of lens position in either young or presbyopic subjects.

  20. Tear analysis in contact lens wearers.

    PubMed Central

    Farris, R L

    1985-01-01

    Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131

  1. Non-destructive geometric and refractive index characterization of single and multi-element lenses using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    El-Haddad, Mohamed T.; Tao, Yuankai K.

    2018-02-01

    Design of optical imaging systems requires careful balancing of lens aberrations to optimize the point-spread function (PSF) and minimize field distortions. Aberrations and distortions are a result of both lens geometry and glass material. While most lens manufacturers provide optical models to facilitate system-level simulation, these models are often not reflective of true system performance because of manufacturing tolerances. Optical design can be further confounded when achromatic or proprietary lenses are employed. Achromats are ubiquitous in systems that utilize broadband sources due to their superior performance in balancing chromatic aberrations. Similarly, proprietary lenses may be custom-designed for optimal performance, but lens models are generally not available. Optical coherence tomography (OCT) provides non-contact, depth-resolved imaging with high axial resolution and sensitivity. OCT has been previously used to measure the refractive index of unknown materials. In a homogenous sample, the group refractive index is obtained as the ratio between the measured optical and geometric thicknesses of the sample. In heterogenous samples, a method called focus-tracking (FT) quantifies the effect of focal shift introduced by the sample. This enables simultaneous measurement of the thickness and refractive index of intermediate sample layers. Here, we extend the mathematical framework of FT to spherical surfaces, and describe a method based on OCT and FT for full characterization of lens geometry and refractive index. Finally, we validate our characterization method on commercially available singlet and doublet lenses.

  2. Relationship of the actual thick intraocular lens optic to the thin lens equivalent.

    PubMed

    Holladay, J T; Maverick, K J

    1998-09-01

    To theoretically derive and empirically validate the relationship between the actual thick intraocular lens and the thin lens equivalent. Included in the study were 12 consecutive adult patients ranging in age from 54 to 84 years (mean +/- SD, 73.5 +/- 9.4 years) with best-corrected visual acuity better than 20/40 in each eye. Each patient had bilateral intraocular lens implants of the same style, placed in the same location (bag or sulcus) by the same surgeon. Preoperatively, axial length, keratometry, refraction, and vertex distance were measured. Postoperatively, keratometry, refraction, vertex distance, and the distance from the vertex of the cornea to the anterior vertex of the intraocular lens (AV(PC1)) were measured. Alternatively, the distance (AV(PC1)) was then back-calculated from the vergence formula used for intraocular lens power calculations. The average (+/-SD) of the absolute difference in the two methods was 0.23 +/- 0.18 mm, which would translate to approximately 0.46 diopters. There was no statistical difference between the measured and calculated values; the Pearson product-moment correlation coefficient from linear regression was 0.85 (r2 = .72, F = 56). The average intereye difference was -0.030 mm (SD, 0.141 mm; SEM, 0.043 mm) using the measurement method and +0.124 mm (SD, 0.412 mm; SEM, 0.124 mm) using the calculation method. The relationship between the actual thick intraocular lens and the thin lens equivalent has been determined theoretically and demonstrated empirically. This validation provides the manufacturer and surgeon additional confidence and utility for lens constants used in intraocular lens power calculations.

  3. Compliance factors associated with contact lens-related dry eye.

    PubMed

    Ramamoorthy, Padmapriya; Nichols, Jason Jay

    2014-01-01

    To determine if compliance factors are associated with contact lens-related dry eye (CLDE). The data were derived from subject responses to a compliance survey administered in a cross-sectional study including 100 healthy, daily (nonovernight), experienced soft contact lens wearers (50 normal and 50 with CLDE). Classification into normal or CLDE groups was based on Contact Lens Dry Eye Questionnaire scores, tear breakup time, and 2 hours difference between total and comfortable daily lens wear hours. The compliance survey queried aspects of lens care, rub and rinse practices, lens and lens case replacement frequency, solution replacement, and sleeping with lenses. Statistical analysis of the data was performed using unpaired T tests, χ, and Fisher exact tests as applicable. The average age of all subjects was 24.8±4.4 years, and 60% were women. Overall compliance rates were low for several variables including recommended replacement of contact lenses (53%), rub and rinse practices (69% and 45%, respectively), care solution topping-off (80%), and washing hands before handling lenses (48%). However, almost no compliance factors were associated with CLDE status, with the exception of perceived ease or difficulty with lens care, which was rated as more difficult by the CLDE group (P=0.004). Overall compliance rates with contact lens care practices are very low, highlighting the need for more effective methods of patient education regarding contact lens care and compliance. However, almost no compliance factors were found to be associated with CLDE. Factors other than compliance likely play a bigger role in CLDE.

  4. Effect of overnight orthokeratology on conjunctival goblet cells.

    PubMed

    Carracedo, Gonzalo; Martin-Gil, Alba; Fonseca, Begoña; Pintor, Jesús

    2016-08-01

    To evaluate the differences between goblet cell density (GCD) and symptomatology after one month of orthokeratology lens wear. A pilot, short-term study was conducted. Twenty-two subjects (29.7±7.0 years old) participated voluntarily in the study. Subjects were divided into two groups: habitual silicone hydrogel contact lens wearers (SiHCLW) and new contact lens wearers (NCLW). Schirmer test, tear break up time (TBUT), Ocular Surface Disease Index (OSDI) questionnaire and conjunctival impression cytology. GCD, mucin cloud height (MCH) and cell layer thickness (CLT) were measured. All measurements were performed before orthokeratology fitting and one month after fitting to assess the evolution of the changes throughout this time. No differences in tear volume and TBUT between groups were found (p>0.05). However, the OSDI score was statistically better after one month of orthokeratology lens wear than the baseline for the SiHCLW group (p=0.03). Regarding the goblet cell analysis, no differences were found in CLT and MCH from the baseline visit to the one month visit for the SiHCLW compared with NCLW groups (p>0.05). At baseline, the GCD in the SiHCLW group were statistically lower than NCLW group (p<0.001). There was a significant increase in GCD after orthokeratology fitting from 121±140cell/mm(2) to 254±130cell/mm(2) (p<0.001) in the SiHCLW group. Orthokeratology improves the dry eye subject symptoms and GCD after one month of wearing in SiHCLW. These results suggest that orthokeratology could be considered a good alternative for silicone hydrogel contact lens discomfort and dryness. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose-Manuel

    2015-01-01

    To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05). Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  6. Early changes in retinal structure and BMP2 expression in the retina and crystalline lens of streptozotocin-induced diabetic pigs.

    PubMed

    Jeong, Jae Seung; Lee, Woon-Kyu; Moon, Yeon Sung; Kim, Na Rae

    2017-09-01

    This study aims to evaluate early changes in retinal structure and BMP2 expression in the retina and crystalline lens by comparing streptozotocin-induced diabetic pigs and normal control group pigs. Five eye samples from five diabetic Micro-pigs (Medikinetics, Pyeongtaek, Korea) and five eye samples from five control pigs bred in a specific pathogen-free area were used. Diabetes was developed through intravenous injection of nicotinamide and streptozotocin, and the average fasting glucose level was maintained at 250 mg/dL or higher for 16 weeks. To evaluate BMP2 expression in the retina and crystalline lens, Western blotting was performed. In Hematoxylin and Eosin staining, most diabetic pigs showed structural abnormalities in the inner plexiform layer. The number of nuclei in the ganglion cell layer within the range of 10 4 µm 2 was 3.78±0.60 for diabetic pigs and 5.57±1.07 for control group pigs, showing a statistically significant difference. In immunohistochemical staining, diabetic retinas showed an overall increase in BMP2 expression. In Western blotting, the average BMP2/actin level of diabetic retinas was 1.19±0.05, showing a significant increase compared to the 1.06±0.03 of the control group retinas ( P =0.016). The BMP2/actin level of diabetic crystalline lenses was similar to the control group crystalline lenses ( P =0.730). Compared to control group pigs, the number of nuclei in the inner nuclear layer of retinas from streptozotocin-induced diabetic pigs decreased, while an increase in BMP2 expression was observed in the retina of diabetic pigs.

  7. Radiation-induced eye lens changes and risk for cataract in interventional cardiology.

    PubMed

    Ciraj-Bjelac, O; Rehani, M; Minamoto, A; Sim, K H; Liew, H B; Vano, E

    2012-01-01

    Recent studies have reported a significant increase in eye lens opacities among staff in the cardiac catheterization laboratory but indicated further studies are needed to confirm the findings. To evaluate the prevalence of opacities in eyes of cardiologists, radiographers and nurses working in interventional cardiology. The eyes of 52 staff in interventional cardiology facilities and 34 age- and sex-matched unexposed controls were screened in a cardiology conference held in Kuala Lumpur by dilated slit-lamp examination, and posterior lens changes were graded. Individual cumulative lens X-ray exposures were calculated from responses to a questionnaire in terms of workload and working practice. The prevalence of posterior lens opacities among interventional cardiologists was 53%, while in nurses and radiographers it was 45%. Corresponding relative risks were 2.6 (95% CI: 1.2-5.4) and 2.2 (95% CI: 0.98-4.9), for interventional cardiologists and support staff, respectively. This study confirms a statistically significant increase in radiation-associated posterior lens changes in the eyes of interventional cardiology staff. Copyright © 2012 S. Karger AG, Basel.

  8. A Measurement of Gravitational Lensing of the Cosmic Microwave Background by Galaxy Clusters Using Data from the South Pole Telescope

    DOE PAGES

    Baxter, E. J.; Keisler, R.; Dodelson, S.; ...

    2015-06-22

    Clusters of galaxies are expected to gravitationally lens the cosmic microwave background (CMB) and thereby generate a distinct signal in the CMB on arcminute scales. Measurements of this effect can be used to constrain the masses of galaxy clusters with CMB data alone. Here we present a measurement of lensing of the CMB by galaxy clusters using data from the South Pole Telescope (SPT). We also develop a maximum likelihood approach to extract the CMB cluster lensing signal and validate the method on mock data. We quantify the effects on our analysis of several potential sources of systematic error andmore » find that they generally act to reduce the best-fit cluster mass. It is estimated that this bias to lower cluster mass is roughly 0.85σ in units of the statistical error bar, although this estimate should be viewed as an upper limit. Furthermore, we apply our maximum likelihood technique to 513 clusters selected via their Sunyaev–Zeldovich (SZ) signatures in SPT data, and rule out the null hypothesis of no lensing at 3.1σ. The lensing-derived mass estimate for the full cluster sample is consistent with that inferred from the SZ flux: M 200,lens = 0.83 +0.38 -0.37 M 200,SZ (68% C.L., statistical error only).« less

  9. [The growth behavior of mouse fibroblasts on intraocular lens surface of various silicone and PMMA materials].

    PubMed

    Kammann, J; Kreiner, C F; Kaden, P

    1994-08-01

    Experience with intraocular lenses (IOL) made of PMMA dates back ca. 40 years, while silicone IOLs have been in use for only about 10 years. The biocompatibility of PMMA and silicone caoutchouc was tested in a comparative study investigating the growth of mouse fibroblasts on different IOL materials. Spectrophotometric determination of protein synthesis and liquid scintillation counting of DNA synthesis were carried out. The spreading of cells was planimetrically determined, and the DNA synthesis of individual cells in direct contact with the test sample was tested. The results showed that the biocompatibility of silicone lenses made of purified caoutchouc is comparable with that of PMMA lenses; there is no statistically significant difference. However, impurities arising during material synthesis result in a statistically significant inhibition of cell growth on the IOL surfaces.

  10. Exploiting chromatic aberration to spectrally encode depth in reflectance confocal microscopy

    NASA Astrophysics Data System (ADS)

    Carrasco-Zevallos, Oscar; Shelton, Ryan L.; Olsovsky, Cory; Saldua, Meagan; Applegate, Brian E.; Maitland, Kristen C.

    2011-06-01

    We present chromatic confocal microscopy as a technique to axially scan the sample by spectrally encoding depth information to avoid mechanical scanning of the lens or sample. We have achieved an 800 μm focal shift over a range of 680-1080 nm using a hyperchromat lens as the imaging lens. A more complex system that incorporates a water immersion objective to improve axial resolution was built and tested. We determined that increasing objective magnification decreases chromatic shift while improving axial resolution. Furthermore, collimating after the hyperchromat at longer wavelengths yields an increase in focal shift.

  11. Binary Sources and Binary Lenses in Microlensing Surveys of MACHOs

    NASA Astrophysics Data System (ADS)

    Petrovic, N.; Di Stefano, R.; Perna, R.

    2003-12-01

    Microlensing is an intriguing phenomenon which may yield information about the nature of dark matter. Early observational searches identified hundreds of microlensing light curves. The data set consisted mainly of point-lens light curves and binary-lens events in which the light curves exhibit caustic crossings. Very few mildly perturbed light curves were observed, although this latter type should constitute the majority of binary lens light curves. Di Stefano (2001) has suggested that the failure to take binary effects into account may have influenced the estimates of optical depth derived from microlensing surveys. The work we report on here is the first step in a systematic analysis of binary lenses and binary sources and their impact on the results of statistical microlensing surveys. In order to asses the problem, we ran Monte-Carlo simulations of various microlensing events involving binary stars (both as the source and as the lens). For each event with peak magnification > 1.34, we sampled the characteristic light curve and recorded the chi squared value when fitting the curve with a point lens model; we used this to asses the perturbation rate. We also recorded the parameters of each system, the maximum magnification, the times at which each light curve started and ended and the number of caustic crossings. We found that both the binarity of sources and the binarity of lenses increased the lensing rate. While the binarity of sources had a negligible effect on the perturbation rates of the light curves, the binarity of lenses had a notable effect. The combination of binary sources and binary lenses produces an observable rate of interesting events exhibiting multiple "repeats" in which the magnification rises above and dips below 1.34 several times. Finally, the binarity of lenses impacted both the durations of the events and the maximum magnifications. This work was supported in part by the SAO intern program (NSF grant AST-9731923) and NASA contracts NAS8-39073 and NAS8-38248 (CXC).

  12. Measurement of the refractive index of soft contact lenses during wear.

    PubMed

    Varikooty, Jalaiah; Keir, Nancy; Woods, Craig A; Fonn, Desmond

    2010-01-01

    To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements. A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means +/- standard errors of the means are reported. In vivo RI values at baseline were 1.422 +/- 0.0004 (lotrafilcon B) and 1.405 +/- 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 +/- 0.0006 and 1.408 +/- 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 +/- 0.0004 and 1.411 +/- 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 +/- 0.0003 (lotrafilcon B) and 1.412 +/- 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P<0.01) but not for the lotrafilcon B lens (P>0.05). This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.

  13. Comparing goblet cell densities in patients wearing disposable hydrogel contact lenses versus silicone hydrogel contact lenses in an extended-wear modality.

    PubMed

    Lievens, Christopher W; Connor, Charles G; Murphy, Heather

    2003-10-01

    The current study evaluates the response of the ocular surface to extended contact lens wear by comparing a new silicone hydrogel lens to an ACUVUE 2 lens. Twenty subjects with an average age of 28 years were randomly assigned to a fitting with ACUVUE 2 or PureVision lenses. Ocular surface assessment by impression cytology was performed at baseline and for the 6 months after initiation of lens wear. Although goblet cell density significantly increased with wear time, no statistically significant difference was observed between the contact lens groups. The average baseline goblet cell percentages were as follows: ACUVUE 2 group, 1.44; PureVision group, 1.11. The 6-month averages were as follows: ACUVUE 2 group, 3.16; PureVision group, 2.22. It appears that silicone hydrogel lenses may be slightly less irritating to the ocular surface than lenses not containing silicone. This could be a promising indicator for successful 30-day continuous wear.

  14. Bulbar conjunctival fluorescein staining in hydrogel contact lens wearers.

    PubMed

    Lakkis, C; Brennan, N A

    1996-07-01

    To evaluate the clinical usefulness of bulbar conjunctival staining in assessing hydrogel contact lens patients. Overall staining, as well as staining at five separate sites (limbal, nasal band, temporal band, superior, and inferior) was graded on an analog scale in 48 contact lens wearing subjects and 50 controls. The degree to which subjects experienced sensations of dryness, wateriness, itchiness, grittiness, and comfort was also assessed using analog scales. Some measure of conjunctival staining was noted in 98% of subjects, with contact lens wearers showing statistically significant greater staining than controls. Only 12% of controls showed staining of greater than grade 1 (equivalent), whereas 62% of contact lens wearers were above this level. Regression analysis showed that overall staining was a function of whether contact lenses were worn, the degree of dryness, and the amount of itchiness. Conjunctival fluorescein staining appears to serve some clinical usefulness as a composite indicator for certain factors and symptoms and, in addition, provides information which is unique for each individual.

  15. Prevalence of lens changes in Ukrainian children residing around Chernobyl

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Day, R.; Gorin, M.B.; Eller, A.W.

    1995-05-01

    The objective of this study is to determine the prevalence and characteristics of lens changes in the eyes of a pediatric population, 5-17 y old, living in the permanent control zone around the Chernobyl nuclear reactor and to compare these findings with those from an unexposed control population. A total of 1,787 children are reported on (996 exposed and 791 unexposed). Over three-quarters of the subjects examined in this study show a form of minor change, termed focal lens defect, in the cortical and/or nuclear portions of the lens of the eye. The exposed group shows a small (3.6%), butmore » statistically significant excess (p = 0.0005) of subclinical posterior subcapsular lens changes similar in form to changes identified in atomic bomb survivors These posterior subcapsular changes tend to occur in boys 12-17 y old and in exposed children who report consuming locally grown mushrooms on a regular basis.« less

  16. Wide-field synovial fluid imaging using polarized lens-free on-chip microscopy for point-of-care diagnostics of gout (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhang, Yibo; Lee, Seung Yoon; Zhang, Yun; Furst, Daniel; Fitzgerald, John; Ozcan, Aydogan

    2016-03-01

    Gout and pseudogout are forms of crystal arthropathy caused by monosodium urate (MSU) and calcium pyrophosphate dehydrate (CPPD) crystals in the joint, respectively, that can result in painful joints. Detecting the unique-shaped, birefringent MSU/CPPD crystals in a synovial fluid sample using a compensated polarizing microscope has been the gold-standard for diagnosis since the 1960's. However, this can be time-consuming and inaccurate, especially if there are only few crystals in the fluid. The high-cost and bulkiness of conventional microscopes can also be limiting for point-of-care diagnosis. Lens-free on-chip microscopy based on digital holography routinely achieves high-throughput and high-resolution imaging in a cost-effective and field-portable design. Here we demonstrate, for the first time, polarized lens-free on-chip imaging of MSU and CPPD crystals over a wide field-of-view (FOV ~ 20.5 mm2, i.e., <20-fold larger compared a typical 20X objective-lens FOV) for point-of-care diagnostics of gout and pseudogout. Circularly polarizer partially-coherent light is used to illuminate the synovial fluid sample on a glass slide, after which a quarter-wave-plate and an angle-mismatched linear polarizer are used to analyze the transmitted light. Two lens-free holograms of the MSU/CPPD sample are taken, with the sample rotated by 90°, to rule out any non-birefringent objects within the specimen. A phase-recovery algorithm is also used to improve the reconstruction quality, and digital pseudo-coloring is utilized to match the color and contrast of the lens-free image to that of a gold-standard microscope image to ease the examination by a rheumatologist or a laboratory technician, and to facilitate computerized analysis.

  17. Investigation into photostability of soybean oils by thermal lens spectroscopy

    NASA Astrophysics Data System (ADS)

    Savi, E. L.; Malacarne, L. C.; Baesso, M. L.; Pintro, P. T. M.; Croge, C.; Shen, J.; Astrath, N. G. C.

    2015-06-01

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented.

  18. [Comparative analysis of visual function and the quality of life index with eyeglasses or a progressive contact lens].

    PubMed

    Sant'Anna, Neusa Vidal; Schor, Paulo; Lipener, César; Uras, Ricardo

    2006-01-01

    To compare the visual function and the answers to a questionnaire of quality of life of patients wearing a progressive contact lens or eyeglasses. The Focus Progressive contact lens had been fitted in 35 patients with far visual acuity with progressive-addition eyeglasses equal to zero (log MAR) and near J1 (Jaeger). The far and near visual acuities and the measurement of contrast sensitivity were compared when the patients were wearing the eyeglasses or the contact lens and the patients' results of the scores of the quality of life questionnaire (NEI VFQ-25) were analyzed statistically considering the type of ametropy and the age. The far and near visual acuities and the contrast sensitivity measurement were worse with the contact lens than with eyeglasses. The answers to the questionnaire did not differ when were comparing the same patients wearing eyeglasses or contact lens, no matter the type of ametropy. The myopic and the hyperopic subgroups had worse answers to the quality of life questionnaire when corrected with the contact lens than with eyeglasses, both with age equal to or less than their median. The visual function was worse with the contact lens. The type of ametropy did not influence the answers to the quality of life questionnaire considering the optical correction, but age did.

  19. Optical high acidity sensor

    DOEpatents

    Jorgensen, Betty S.; Nekimken, Howard L.; Carey, W. Patrick; O'Rourke, Patrick E.

    1997-01-01

    An apparatus and method for determining acid concentrations in solutions having acid concentrations of from about 0.1 Molar to about 16 Molar is disclosed. The apparatus includes a chamber for interrogation of the sample solution, a fiber optic light source for passing light transversely through the chamber, a fiber optic collector for receiving the collimated light after transmission through the chamber, a coating of an acid resistant polymeric composition upon at least one fiber end or lens, the polymeric composition in contact with the sample solution within the chamber and having a detectable response to acid concentrations within the range of from about 0.1 Molar to about 16 Molar, a measurer for the response of the polymeric composition in contact with the sample solution, and, a comparer of the measured response to predetermined standards whereby the acid molarity of the sample solution within the chamber can be determined. Preferably, a first lens is attached to the end of the fiber optic light source, the first lens adapted to collimate light from the fiber optic light source, and a second lens is attached to the end of the fiber optic collector for focusing the collimated light after transmission through the chamber.

  20. Optical high acidity sensor

    DOEpatents

    Jorgensen, B.S.; Nekimken, H.L.; Carey, W.P.; O`Rourke, P.E.

    1997-07-22

    An apparatus and method for determining acid concentrations in solutions having acid concentrations of from about 0.1 Molar to about 16 Molar is disclosed. The apparatus includes a chamber for interrogation of the sample solution, a fiber optic light source for passing light transversely through the chamber, a fiber optic collector for receiving the collimated light after transmission through the chamber, a coating of an acid resistant polymeric composition upon at least one fiber end or lens, the polymeric composition in contact with the sample solution within the chamber and having a detectable response to acid concentrations within the range of from about 0.1 Molar to about 16 Molar, a measurer for the response of the polymeric composition in contact with the sample solution, and a comparer of the measured response to predetermined standards whereby the acid molarity of the sample solution within the chamber can be determined. Preferably, a first lens is attached to the end of the fiber optic light source, the first lens adapted to collimate light from the fiber optic light source, and a second lens is attached to the end of the fiber optic collector for focusing the collimated light after transmission through the chamber. 10 figs.

  1. Line-of-sight effects in strong lensing: putting theory into practice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birrer, Simon; Welschen, Cyril; Amara, Adam

    2017-04-01

    We present a simple method to accurately infer line of sight (LOS) integrated lensing effects for galaxy scale strong lens systems through image reconstruction. Our approach enables us to separate weak lensing LOS effects from the main strong lens deflector. We test our method using mock data and show that strong lens systems can be accurate probes of cosmic shear with a precision on the shear terms of ± 0.003 (statistical error) for an HST-like dataset. We apply our formalism to reconstruct the lens COSMOS 0038+4133 and its LOS. In addition, we estimate the LOS properties with a halo-rendering estimatemore » based on the COSMOS field galaxies and a galaxy-halo connection. The two approaches are independent and complementary in their information content. We find that when estimating the convergence at the strong lens system, performing a joint analysis improves the measure by a factor of two compared to a halo model only analysis. Furthermore the constraints of the strong lens reconstruction lead to tighter constraints on the halo masses of the LOS galaxies. Joint constraints of multiple strong lens systems may add valuable information to the galaxy-halo connection and may allow independent weak lensing shear measurement calibrations.« less

  2. [Magnetic resonance imaging study of effects of accommodation on human lens morphological characters].

    PubMed

    Zheng, Sui-lian; Zhang, Ai; Shi, Jian-jing; Zhou, Yun-xin

    2013-11-05

    To evaluate the effects of accommodation on lens morphological characters. From January 2011 to June 2011, magnetic resonance images of eyes were acquired from 30 subjects aged 20 to 24 years during accommodation and at rest. The optimal images were analyzed by Autocad 2010 to obtain the total lens cross-sectional area (CSA) and CSA of anterior and posterior portions of lens, anterior chamber depth, lens thickness, lens diameter, vitreous chamber depth and axial length during accommodation and at rest. Paired-t test was performed. The anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (8.7 ± 0.8), (6.2 ± 0.5), (7.5 ± 2.1), (12.0 ± 2.6), (20 ± 4) during relaxed accommodation; anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (7.1 ± 1.3), (5.6 ± 0.5), (14.7 ± 2.9), (12.2 ± 2.1) and (27 ± 4) during accommodation. The total lens CSA (t = -11.556, P < 0.01) and CSA of anterior portion (t = -15.653, P < 0.01) both increased in accommodative states. The CSA of posterior portion of lens (t = -0.437, P > 0.05) under a statistically independent accommodative state. There was significant difference in the anterior chamber depth (t = 4.366, P < 0.01), lens thickness (t = -5.456, P < 0.01) and lens diameter (t = 4.597, P < 0.01) in accommodative states. There were insignificant differences both in vitreous chamber depth (t = 0.428, P > 0.05) and axial length (t = 0.418, P > 0.05) under accommodative states. During accommodation, the anterior chamber depth decreases, lens thickness increases and diameter of lens decreases while anterior portions and total lens CSA increase. There are insignificant changes in posterior portions of lens CSA, vitreous chamber depth and axial length. The accommodative changes in CSA indicate that the anterior portion of lens may be related with the properties of anterior capsule and lens material, the position of zonular attachments and the location of fetal nucleus. Helmholtz theory is supported.

  3. OCT 3-D surface topography of isolated human crystalline lenses

    PubMed Central

    Sun, Mengchan; Birkenfeld, Judith; de Castro, Alberto; Ortiz, Sergio; Marcos, Susana

    2014-01-01

    Quantitative 3-D Optical Coherence Tomography was used to measure surface topography of 36 isolated human lenses, and to evaluate the relationship between anterior and posterior lens surface shape and their changes with age. All lens surfaces were fitted to 6th order Zernike polynomials. Astigmatism was the predominant surface aberration in anterior and posterior lens surfaces (accounting for ~55% and ~63% of the variance respectively), followed by spherical terms, coma, trefoil and tetrafoil. The amount of anterior and posterior surface astigmatism did not vary significantly with age. The relative angle between anterior and posterior surface astigmatism axes was on average 36.5 deg, tended to decrease with age, and was >45 deg in 36.1% lenses. The anterior surface RMS spherical term, RMS coma and 3rd order RMS decreased significantly with age. In general, there was a statistically significant correlation between the 3rd and 4th order terms of the anterior and posterior surfaces. Understanding the coordination of anterior and posterior lens surface geometries and their topographical changes with age sheds light into the role of the lens in the optical properties of the eye and the lens aging mechanism. PMID:25360371

  4. OCT 3-D surface topography of isolated human crystalline lenses.

    PubMed

    Sun, Mengchan; Birkenfeld, Judith; de Castro, Alberto; Ortiz, Sergio; Marcos, Susana

    2014-10-01

    Quantitative 3-D Optical Coherence Tomography was used to measure surface topography of 36 isolated human lenses, and to evaluate the relationship between anterior and posterior lens surface shape and their changes with age. All lens surfaces were fitted to 6th order Zernike polynomials. Astigmatism was the predominant surface aberration in anterior and posterior lens surfaces (accounting for ~55% and ~63% of the variance respectively), followed by spherical terms, coma, trefoil and tetrafoil. The amount of anterior and posterior surface astigmatism did not vary significantly with age. The relative angle between anterior and posterior surface astigmatism axes was on average 36.5 deg, tended to decrease with age, and was >45 deg in 36.1% lenses. The anterior surface RMS spherical term, RMS coma and 3rd order RMS decreased significantly with age. In general, there was a statistically significant correlation between the 3rd and 4th order terms of the anterior and posterior surfaces. Understanding the coordination of anterior and posterior lens surface geometries and their topographical changes with age sheds light into the role of the lens in the optical properties of the eye and the lens aging mechanism.

  5. Conceptual design study of a 5 kilowatt solar dynamic Brayton power system using a dome Fresnel lens solar concentrator

    NASA Technical Reports Server (NTRS)

    Oneill, Mark J.; Mcdanal, A. J.; Spears, Don H.

    1989-01-01

    The primary project objective was to generate a conceptual design for a nominal 5 kW solar dynamic space power system, which uses a unique, patented, transmittance-optimized, dome-shaped, point-focus Fresnel lens as the optical concentrator. Compared to reflective concentrators, the dome lens allows 200 times larger slope errors for the same image displacement. Additionally, the dome lens allows the energy receiver, the power conversion unit (PCU), and the heat rejection radiator to be independently optimized in configuration and orientation, since none of these elements causes any aperture blockage. Based on optical and thermal trade studies, a 6.6 m diameter lens with a focal length of 7.2 m was selected. This lens should provide 87 percent net optical efficienty at 800X geometric concentration ratio. The large lens is comprised of 24 gores, which compactly stow together during launch, and automatically deploy on orbit. The total mass of the microglass lens panels, the graphite/epoxy support structure, and miscellaneous hardware is about 1.2 kg per square meter of aperture. The key problem for the dome lens approach relates to the selection of a space-durable lens material. For the first time, all-glass Fresnel lens samples were successfully made by a sol-gel casting process.

  6. Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.

    PubMed

    Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi

    2013-09-01

    It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  7. A longitudinal study assessing lens thickness changes in the eye of the growing beagle using ultrasound scanning: relevance to age of dogs in regulatory toxicology studies.

    PubMed

    Maynard, Juliana; Sykes, Angela; Powell, Helen; Healing, Guy; Scott, Marietta; Holmes, Andrew; Ricketts, Sally-Ann; Stewart, Jane; Davis, Stewart

    2014-12-01

    The lens is formed in utero with new secondary lens fibres added as outer layers throughout life in a growth pattern characteristic of the species. This study examined the time course of beagle lens growth to better understand the optimal starting age of dogs for safety studies to support adult versus paediatric indications, and to assess the feasibility of non-invasively monitoring lens growth with high frequency ultrasound. Ultrasound scanning was performed in six female beagle dogs using the Vevo770. All dogs were imaged in B-mode using local anaesthetic but without sedation. Imaging was carried out every 2 weeks from 8 to 22 weeks of age and then monthly until 62 weeks of age. The dogs tolerated the procedure well. The lens was visible in all dogs and measuring the lens thickness with high frequency ultrasound demonstrated good analytical reproducibility [Root Mean Square (RMS) = 3.13%]. No differences between the left and right eye existed and lens thickness correlated with body weight. The highest weekly growth rate was before 12 weeks of age. A statistically significant difference between monthly thickness was detected until 42 weeks of age at which point growth reached a plateau. During the experiment, lenses grew by 29.7% reaching an average thickness of 6.4 mm ± 0.03. By 10 months of age (the typical age used for routine toxicological evaluation), beagles have reached a plateau in lens growth that is analogous to human adults. Where lens is a target organ of concern it is suggested that beagles under 6 months old may be a better model for determining paediatric safety. Copyright © 2014 John Wiley & Sons, Ltd.

  8. FPscope: a field-portable high-resolution microscope using a cellphone lens.

    PubMed

    Dong, Siyuan; Guo, Kaikai; Nanda, Pariksheet; Shiradkar, Radhika; Zheng, Guoan

    2014-10-01

    The large consumer market has made cellphone lens modules available at low-cost and in high-quality. In a conventional cellphone camera, the lens module is used to demagnify the scene onto the image plane of the camera, where image sensor is located. In this work, we report a 3D-printed high-resolution Fourier ptychographic microscope, termed FPscope, which uses a cellphone lens in a reverse manner. In our platform, we replace the image sensor with sample specimens, and use the cellphone lens to project the magnified image to the detector. To supersede the diffraction limit of the lens module, we use an LED array to illuminate the sample from different incident angles and synthesize the acquired images using the Fourier ptychographic algorithm. As a demonstration, we use the reported platform to acquire high-resolution images of resolution target and biological specimens, with a maximum synthetic numerical aperture (NA) of 0.5. We also show that, the depth-of-focus of the reported platform is about 0.1 mm, orders of magnitude longer than that of a conventional microscope objective with a similar NA. The reported platform may enable healthcare accesses in low-resource settings. It can also be used to demonstrate the concept of computational optics for educational purposes.

  9. IMPACT OF A RINSE STEP ON PROTEIN REMOVAL FROM SILICONE HYDROGEL CONTACT LENSES

    PubMed Central

    Pucker, Andrew D.; Nichols, Jason J.

    2010-01-01

    PURPOSE To determine the impact of the rinse step in “no rub” contact lens care systems relative to its ability to assist in removing loosely associated and bound tear film proteins from a worn silicone hydrogel lens. METHODS After informed consent, subjects were fitted with lotrafilcon B contact lenses (CIBA Vision, Inc). If the fit was acceptable, subjects were asked to wear the lenses on a daily wear basis for 5 (+2, −0) days for an outcome visit. Subjects were instructed to use AQuify Multi-Purpose Disinfecting Solution (CIBA Vision, Inc) following the manufacturer's “no rub” instructions. At the outcome visit, contact lenses were then collected by a gloved examiner, with a sterile metal forceps, who rinsed the right lens but did not rinse the left lens upon removal from the eyes. Protein was extracted with a 50:50 0.2% trifluoroacetic acid-acetonitrile solution and quantified using a Bradford analyses. RESULTS Twenty contact lens wearers were enrolled in this study. For the non-rinsed lenses, the first extraction yielded 13.4 ± 9.2 µg/lens of protein, while the second extraction yielded 5.8 ± 2.8 µg/lens of protein. For the rinsed lenses, first extraction yielded an average of 3.0 ± 1.9 µg/lens of protein, while the second extraction yielded an average of 4.0 ± 2.3 µg/lens. Repeated measures ANOVA showed a significant interaction (F-statistic = 18.9, p< 0.0001) between the rinse of a lens and extraction number. CONCLUSIONS Rinsing a contact lens following removal from the eye removes well over one-half of the protein associated with it. Further, in order to biochemically recover all protein from a silicone hydrogel lens, it may be important to perform more than one chemical extraction from it. PMID:19609231

  10. Improving the lens design and performance of a contemporary electromagnetic shock wave lithotripter

    PubMed Central

    Neisius, Andreas; Smith, Nathan B.; Sankin, Georgy; Kuntz, Nicholas John; Madden, John Francis; Fovargue, Daniel E.; Mitran, Sorin; Lipkin, Michael Eric; Simmons, Walter Neal; Preminger, Glenn M.; Zhong, Pei

    2014-01-01

    The efficiency of shock wave lithotripsy (SWL), a noninvasive first-line therapy for millions of nephrolithiasis patients, has not improved substantially in the past two decades, especially in regard to stone clearance. Here, we report a new acoustic lens design for a contemporary electromagnetic (EM) shock wave lithotripter, based on recently acquired knowledge of the key lithotripter field characteristics that correlate with efficient and safe SWL. The new lens design addresses concomitantly three fundamental drawbacks in EM lithotripters, namely, narrow focal width, nonidealized pulse profile, and significant misalignment in acoustic focus and cavitation activities with the target stone at high output settings. Key design features and performance of the new lens were evaluated using model calculations and experimental measurements against the original lens under comparable acoustic pulse energy (E+) of 40 mJ. The −6-dB focal width of the new lens was enhanced from 7.4 to 11 mm at this energy level, and peak pressure (41 MPa) and maximum cavitation activity were both realigned to be within 5 mm of the lithotripter focus. Stone comminution produced by the new lens was either statistically improved or similar to that of the original lens under various in vitro test conditions and was significantly improved in vivo in a swine model (89% vs. 54%, P = 0.01), and tissue injury was minimal using a clinical treatment protocol. The general principle and associated techniques described in this work can be applied to design improvement of all EM lithotripters. PMID:24639497

  11. Improving the lens design and performance of a contemporary electromagnetic shock wave lithotripter.

    PubMed

    Neisius, Andreas; Smith, Nathan B; Sankin, Georgy; Kuntz, Nicholas John; Madden, John Francis; Fovargue, Daniel E; Mitran, Sorin; Lipkin, Michael Eric; Simmons, Walter Neal; Preminger, Glenn M; Zhong, Pei

    2014-04-01

    The efficiency of shock wave lithotripsy (SWL), a noninvasive first-line therapy for millions of nephrolithiasis patients, has not improved substantially in the past two decades, especially in regard to stone clearance. Here, we report a new acoustic lens design for a contemporary electromagnetic (EM) shock wave lithotripter, based on recently acquired knowledge of the key lithotripter field characteristics that correlate with efficient and safe SWL. The new lens design addresses concomitantly three fundamental drawbacks in EM lithotripters, namely, narrow focal width, nonidealized pulse profile, and significant misalignment in acoustic focus and cavitation activities with the target stone at high output settings. Key design features and performance of the new lens were evaluated using model calculations and experimental measurements against the original lens under comparable acoustic pulse energy (E+) of 40 mJ. The -6-dB focal width of the new lens was enhanced from 7.4 to 11 mm at this energy level, and peak pressure (41 MPa) and maximum cavitation activity were both realigned to be within 5 mm of the lithotripter focus. Stone comminution produced by the new lens was either statistically improved or similar to that of the original lens under various in vitro test conditions and was significantly improved in vivo in a swine model (89% vs. 54%, P = 0.01), and tissue injury was minimal using a clinical treatment protocol. The general principle and associated techniques described in this work can be applied to design improvement of all EM lithotripters.

  12. Bulk combinatorial synthesis and high throughput characterization for rapid assessment of magnetic materials: Application of laser engineered net shaping (LENS)

    DOE PAGES

    Geng, J.; Nlebedim, I. C.; Besser, M. F.; ...

    2016-04-15

    A bulk combinatorial approach for synthesizing alloy libraries using laser engineered net shaping (LENS; i.e., 3D printing) was utilized to rapidly assess material systems for magnetic applications. The LENS system feeds powders in different ratios into a melt pool created by a laser to synthesize samples with bulk (millimeters) dimensions. By analyzing these libraries with autosampler differential scanning calorimeter/thermal gravimetric analysis and vibrating sample magnetometry, we are able to rapidly characterize the thermodynamic and magnetic properties of the libraries. Furthermore, the Fe-Co binary alloy was used as a model system and the results were compared with data in the literature.

  13. In-line FINCH super resolution digital holographic fluorescence microscopy using a high efficiency transmission liquid crystal GRIN lens.

    PubMed

    Brooker, Gary; Siegel, Nisan; Rosen, Joseph; Hashimoto, Nobuyuki; Kurihara, Makoto; Tanabe, Ayano

    2013-12-15

    We report a new optical arrangement that creates high-efficiency, high-quality Fresnel incoherent correlation holography (FINCH) holograms using polarization sensitive transmission liquid crystal gradient index (TLCGRIN) diffractive lenses. In contrast, current universal practice in the field employs a reflective spatial light modulator (SLM) to separate sample and reference beams. Polarization sensitive TLCGRIN lenses enable a straight optical path, have >90% transmission efficiency, are not pixilated, and are free of many limitations of reflective SLM devices. For each sample point, two spherical beams created by a glass lens in combination with a polarization sensitive TLCGRIN lens interfere and create a hologram and resultant super resolution image.

  14. The influence of rigid gas permeable lens wear on the concentrations of dinucleotides in tears and the effect on dry eye signs and symptoms in keratoconus.

    PubMed

    Carracedo, Gonzalo; González-Méijome, José Manuel; Martín-Gil, Alba; Carballo, Jesús; Pintor, Jesús

    2016-10-01

    To evaluate the signs and symptoms of dry eye and dinucleotide secretion in tears of keratoconus patients (KC) and the potential effect of rigid gas permeable (RGP) contact lens wear. Twenty-three KC patients and forty control subjects were enrolled in this study. Signs of dry eye including tear volume, tear stability and corneal staining along with symptoms were assessed using the McMonnies questionnaire. Tears were collected using Schirmer strips, and dinucleotide concentrations in collected tears measured using high pressure liquid chromatography. Values obtained in KC and controls were compared. The effect of contact lens wear in KC was also assessed. KC eyes showed a significantly lower tear volume compared to controls, shorter tear break up time (TBUT), higher corneal staining and higher McMonnies dry eye questionnaire scores (p<0.05). When compared with non-wearers, KC contact lens wearers showed significantly higher symptoms, lower Schirmer and TBUT values (p<0.05). Concentration of Ap4A (0.695±0.304μM vs. 0.185±0.178μM) and Ap5A (0.132±0.128μM vs. 0.045±0.036μM) were higher in KC compared to controls (p<0.001) and only Ap4A was statistically higher in RGP wearers compared to non-wearers (0.794±0.478μM vs. 0.417±0.313μM) (p<0.05). Signs and symptoms of dry eye as well as concentrations of Ap4A and Ap5A were markedly increased in KC patients compared to controls. Moreover, Ap4A and symptoms of dry eye were statistically higher in RGP wearers compared to non-wearers. This seems to indicate that factors such as RGP contact lens wear might exacerbate the clinical condition of dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  15. Single optical fiber probe for optogenetics

    NASA Astrophysics Data System (ADS)

    Falk, Ryan; Habibi, Mohammad; Pashaie, Ramin

    2012-03-01

    With the advent of optogenetics, all optical control and visualization of the activity of specific cell types is possible. We have developed a fiber optic based probe to control/visualize neuronal activity deep in the brain of awake behaving animals. In this design a thin multimode optical fiber serves as the head of the probe to be inserted into the brain. This fiber is used to deliver excitation/stimulation optical pulses and guide a sample of the emission signal back to a detector. The major trade off in the design of such a system is to decrease the size of the fiber and intensity of input light to minimize physical damage and to avoid photobleaching/phototoxicity but to keep the S/N reasonably high. Here the excitation light, and the associated emission signal, are frequency modulated. Then the output of the detector is passed through a time-lens which compresses the distributed energy of the emission signal and maximizes the instantaneous S/N. By measuring the statistics of the noise, the structure of the time lens can be designed to achieve the global optimum of S/N. Theoretically, the temporal resolution of the system is only limited by the time lens diffraction limit. By adding a second detector, we eliminated the effect of input light fluctuations, imperfection of the optical filters, and back-reflection of the excitation light. We have also designed fibers and micro mechanical assemblies for distributed delivery and detection of light.

  16. Eye Lens Radiation Exposure in Greek Interventional Cardiology Article.

    PubMed

    Thrapsanioti, Zoi; Askounis, Panagiotis; Datseris, Ioannis; Diamanti, Ramza Anastasia; Papathanasiou, Miltiadis; Carinou, Eleftheria

    2017-07-01

    The lens of the eye is one of the radiosensitive tissues of the human body; if exposed to ionizing radiation can develop radiation-induced cataract at early ages. This study was held in Greece and included 44 Interventional Cardiologists (ICs) and an unexposed to radiation control group of 22 persons. Of the note, 26 ICs and the unexposed individuals underwent special eye examinations. The detected lens opacities were classified according to LOCS III protocol. Additionally, the lens doses of the ICs were measured using eye lens dosemeters. The mean dose to the lenses of the ICs per month was 0.83 ± 0.59 mSv for the left and 0.35 ± 0.38 mSv for the right eye, while the annual doses ranged between 0.7 and 11 mSv. Regarding the lens opacities, the two groups did not differ significantly in the prevalence of either nuclear or cortical lens opacities, whereas four ICs were detected with early stage subcapsular sclerosis. Though no statistically difference was observed in the cohort, the measured doses indicate that the eye doses received from the ICs can be significant. To minimize the radiation-induced risk at the eye lenses, the use of protective equipment and appropriate training on this issue is highly recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Density of the crystalline lens in obese and nonobese children.

    PubMed

    Acer, Semra; Ağladıoğlu, Sebahat Yılmaz; Pekel, Gökhan; Özhan, Bayram; Çetin, Ebru Nevin; Yağcı, Ramazan; Yıldırım, Cem

    2016-02-01

    To compare crystalline lens density in obese and nonobese children. A total of 40 obese (25 females) and 46 age-sex matched controls (26 females) were included in this prospective study. Children with ocular diseases (except for mild refractive errors), ocular trauma, or surgery and any systemic disorders, including diabetes, were excluded. Lens densitometry (LD), central corneal thickness (CCT), anterior chamber depth (ACD) and corneal volume (CV) were measured by Pentacam HR. Mean participant age was 12.0 ± 1.9 (range, 7.2-18 years) in the obese group and 11.7 ± 2.0 (range, 7.5-16.1 years) in the control group. The BMI was 29.9 ± 4.5 in the obese group and 18.7 ± 2.5 in the control group (P ≤ 0.05). The vertical, horizontal, and areal lens density measurements were higher in obese group than in controls (P ≤ 0.05). There was a positive correlation between BMI and vertical, horizontal, and areal lens density measurements. The difference in CCT, ACD, and CV was not statistically significant between groups (P ≥ 0.05). There is increased lens density in the obese children compared with controls. Pentacam HR may provide objective data about lens density in children. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  18. Vision of low astigmats through thick and thin lathe-cut soft contact lenses.

    PubMed

    Cho, P; Woo, G C

    2001-01-01

    Distance and near visual acuity of 13 low astigmats were determined in a double-masked experiment through thick and thin (centre thickness 0.12 mm and 0.06 mm, respectively) spherical lathe-cut soft lenses. For each lens type, distance and near LogMAR VA and over-refraction were assessed with different logMAR VA charts. For 70% of the subjects, the residual astigmatism was significantly lower than the refractive astigmatism with thicker lenses. No statistically significant differences in the distance and near logMAR VA was found between the two lens types using any of the charts used, though, in general, logMAR VA obtained through the thicker lens was better than logMAR VA through the thinner lens. The variabilities in distance and near logMAR VA between the two lens types increased with decreased contrast. The variabilities in distance logMAR VA were greater with Chinese charts than with English charts, and LogMAR VA with Chinese charts were significantly worse for both lens types. Based on the results of this study, we concluded that thicker spherical lathe-cut soft lenses provide better vision in low astigmats. The Snellen acuity test is inadequate for vision assessment of soft contact lens wearers. When a patient wearing thin soft contact lenses complains of poor vision in spite of 6/6 or 6/5 Snellen acuity, changing to thicker lenses may be considered.

  19. Ultrasonically Absorptive Coatings for Hypersonic Laminar Flow Control

    DTIC Science & Technology

    2007-12-01

    integratt JAC and TPS functions. To aid in the design of UAC with regular microstructure to be tested the CUBRC LENS I tunnel, parametric studies of th...solid foundation for large-scale demonstration of the UAC-LFC performance the CUBRC LENS I -tnel as wel as fabrication of ceramic UAC samples...with regular microstructure to be tested the CUBRC LENS I tunnel, extensive parametric studies of the UAC laminar flow control performance were conducted

  20. Ultrasonically Absorptive Coatings for Hypersonic

    DTIC Science & Technology

    2008-05-13

    UAC and TPS functions. To aid in the design of UAC with regular microstructure to be tested the CUBRC LENS I tunnel, parametric studies of the UAC-LFC...approaching the large-scale demonstration stage in the CUBRC LENS tunnel as well as fabrication of ceramic UAC samples integrated into TPS. Summary...integrate UAC and TPS functions. To aid in the design of UAC with regular microstructure to be tested the CUBRC LENS I tunnel, parametric studies of

  1. Rotation of lathe-cut hydrogel lenses on the eye.

    PubMed

    Harris, M G; Harris, K L; Ruddell, D

    1976-01-01

    The rotation lathe-cut HydroCurveTM gel contact lens was measured on six eyes to evaluate the parameters that influence lens rotation and to determine if this lens could be used to correct astigmatism. Of the 72 observations made, 73.6% showed some lens rotation, and 33.4% of the sample rotated more than 5 degrees per 10 blinks. Of the observations in which rotation was noted, 88.7% were encyclorotation. These results are similar to those found for spin-cast hydrogel lenses. None of the lens parameters evaluated seemed to be related to lens rotation, whereas the eye parameters studied were. Lenses were more likely to rotate on eyes with smaller corneal diameters, smaller palpebral apertures, and corneal curvatures steeper than 4 3.00 DK (X2, N =72, p less than 0.05). Our findings indicate that some method of lens stabilization will be needed before lathe-cut hydrogel lenses can be used to effectively correct astigmatism.

  2. Expression Profiling of Nonpolar Lipids in Meibum From Patients With Dry Eye: A Pilot Study

    PubMed Central

    Chen, Jianzhong; Keirsey, Jeremy K.; Green, Kari B.; Nichols, Kelly K.

    2017-01-01

    Purpose The purpose of this investigation was to characterize differentially expressed lipids in meibum samples from patients with dry eye disease (DED) in order to better understand the underlying pathologic mechanisms. Methods Meibum samples were collected from postmenopausal women with DED (PW-DED; n = 5) and a control group of postmenopausal women without DED (n = 4). Lipid profiles were analyzed by direct infusion full-scan electrospray ionization mass spectrometry (ESI-MS). An initial analysis of 145 representative peaks from four classes of lipids in PW-DED samples revealed that additional manual corrections for peak overlap and isotopes only slightly affected the statistical analysis. Therefore, analysis of uncorrected data, which can be applied to a greater number of peaks, was used to compare more than 500 lipid peaks common to PW-DED and control samples. Statistical analysis of peak intensities identified several lipid species that differed significantly between the two groups. Data from contact lens wearers with DED (CL-DED; n = 5) were also analyzed. Results Many species of the two types of diesters (DE) and very long chain wax esters (WE) were decreased by ∼20% in PW-DED, whereas levels of triacylglycerols were increased by an average of 39% ± 3% in meibum from PW-DED compared to that in the control group. Approximately the same reduction (20%) of similar DE and WE was observed for CL-DED. Conclusions Statistical analysis of peak intensities from direct infusion ESI-MS results identified differentially expressed lipids in meibum from dry eye patients. Further studies are warranted to support these findings. PMID:28426869

  3. Comparison of AL-Scan and IOLMaster 500 Partial Coherence Interferometry Optical Biometers.

    PubMed

    Hoffer, Kenneth J; Savini, Giacomo

    2016-10-01

    To investigate agreement between the ocular biometry measurements provided by a newer optical biometer, the AL-Scan (Nidek Co, Ltd., Gamagori, Japan) and those provided by the IOLMaster 500 (Carl Zeiss Meditec, Jena Germany), which are both based on partial coherence interferometry. Axial length, corneal power, and anterior chamber depth (corneal epithelium to lens) were measured in 86 eyes of 86 patients scheduled for cataract surgery using both biometers. All values were analyzed using a paired t test, the Pearson product moment correlation coefficient (r), and Bland-Altman plots. The mean axial length values of both instruments were exactly the same (23.46 ± 0.99 mm) for both) and showed excellent agreement and correlation. On the contrary, the AL-Scan measured a steeper mean corneal power by 0.08 diopters (D) at the 2.4-mm zone but by only 0.03 D at the 3.3-mm zone, only the former being statistically significant. The AL-Scan measured a deeper anterior chamber depth by 0.13 mm, which was statistically significant (P < .001). Agreement between the two units was good. However, the small but statistically significant difference in corneal power (at the IOLMaster-comparable 2.4-mm zone) and in the anterior chamber depth measurement make lens constant optimization necessary when calculating the intraocular lens power by means of theoretical formulas. [J Refract Surg. 2016;32(10):694-698.]. Copyright 2016, SLACK Incorporated.

  4. The Effects of Surgical Factors on Postoperative Astigmatism in Patients Enrolled in the Infant Aphakia Treatment Study (IATS)

    PubMed Central

    Wall, Palak B.; Lee, Jason A.; Lynn, Michael; Lambert, Scott R.; Traboulsi, Elias I.

    2015-01-01

    Purpose To evaluate the impact of surgical factors such as incision type, number of sutures, and technique of closure on postoperative astigmatism in infants undergoing cataract extraction with or without intraocular lens implantation. Methods The IATS is a multicenter (n=12) clinical trial in which 114 infants with unilateral congenital cataracts were randomized to undergo cataract extraction with intraocular lens (IOL) placement or contact lens aphakic correction. Surgical videos were reviewed with regard to incision type and location, whether the incision was extended, the number of sutures placed, and technique of closure. Corneal astigmatism was measured using a handheld keratometer prior to surgery and at 1 year of age. Results Corneal astigmatism decreased from a mean of 1.92 D at baseline to 1.62 D at age 1 year in the CL group, but remained almost unchanged from 2.00 D to 2.09 D in the IOL group (p=0.023). There was no statistical difference between the amount of corneal astigmatism irrespective of incision type (p=0.214) and no increase in astigmatism with extension of the incision to facilitate IOL placement (p=0.849) at 1 year. The number of sutures and technique of closure did not influence the amount of astigmatism at 1 year. Conclusions At the age of one year following cataract extraction in infants, contact lens correction and the lack of IOL placement are associated with a significant decrease in postoperative corneal astigmatism compared to intraocular lens placement. No other surgical factors considered in this study had a statistically significant impact on corneal astigmatism. PMID:25266831

  5. Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography.

    PubMed

    Güell, José Luis; Morral, Merce; Gris, Oscar; Gaytan, Javier; Sisquella, Maite; Manero, Felicidad

    2007-08-01

    To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) Institutional practice. Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.

  6. Automated Micro-Object Detection for Mobile Diagnostics Using Lens-Free Imaging Technology

    PubMed Central

    Roy, Mohendra; Seo, Dongmin; Oh, Sangwoo; Chae, Yeonghun; Nam, Myung-Hyun; Seo, Sungkyu

    2016-01-01

    Lens-free imaging technology has been extensively used recently for microparticle and biological cell analysis because of its high throughput, low cost, and simple and compact arrangement. However, this technology still lacks a dedicated and automated detection system. In this paper, we describe a custom-developed automated micro-object detection method for a lens-free imaging system. In our previous work (Roy et al.), we developed a lens-free imaging system using low-cost components. This system was used to generate and capture the diffraction patterns of micro-objects and a global threshold was used to locate the diffraction patterns. In this work we used the same setup to develop an improved automated detection and analysis algorithm based on adaptive threshold and clustering of signals. For this purpose images from the lens-free system were then used to understand the features and characteristics of the diffraction patterns of several types of samples. On the basis of this information, we custom-developed an automated algorithm for the lens-free imaging system. Next, all the lens-free images were processed using this custom-developed automated algorithm. The performance of this approach was evaluated by comparing the counting results with standard optical microscope results. We evaluated the counting results for polystyrene microbeads, red blood cells, HepG2, HeLa, and MCF7 cells lines. The comparison shows good agreement between the systems, with a correlation coefficient of 0.91 and linearity slope of 0.877. We also evaluated the automated size profiles of the microparticle samples. This Wi-Fi-enabled lens-free imaging system, along with the dedicated software, possesses great potential for telemedicine applications in resource-limited settings. PMID:27164146

  7. Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements.

    PubMed

    Cerviño, Alejandro; Gonzalez-Meijome, Jose M; Linhares, João M M; Hosking, Sarah L; Montes-Mico, Robert

    2008-03-01

    To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- 0.10 with the clear Optima 38 CL. Straylight values were 0.97 +/- 0.10 and 1.0 +/- 0.10 log units with the amber and grey-green tinted CL, respectively. Differences in straylight between baseline (without CL) and with the clear CL in place were neither statistically significant (p = 0.066) nor was there a significant difference between baseline and the amber CL (p = 0.052). However, the grey-green CL showed a statistically significant difference from baseline (p = 0.006). Differences in straylight with the clear CL compared with the grey-green CL were also statistically different from zero (p = 0.002) showing an increased straylight value for the tinted CL. These differences were variable, but consistent for each subject, thus those showing higher or lower changes with one tinted lens tended to show the same trend with the second lens (r(2) = 0.736). Despite increases having been found in straylight values with tinted contact lenses, those changes are not likely to induce clinically significant changes in visual function under photopic conditions, even for the grey-green CL, which seems to increase straylight values more significantly than the amber CL. This difference between the tinted CL could suggest a wavelength dependence of straylight values, although this should be investigated further by controlling for pupil size and subjects' pigmentation, as well as by using neutral density filters.

  8. Cryogenic immersion microscope

    DOEpatents

    Le Gros, Mark; Larabell, Carolyn A.

    2010-12-14

    A cryogenic immersion microscope whose objective lens is at least partially in contact with a liquid reservoir of a cryogenic liquid, in which reservoir a sample of interest is immersed is disclosed. When the cryogenic liquid has an index of refraction that reduces refraction at interfaces between the lens and the sample, overall resolution and image quality are improved. A combination of an immersion microscope and x-ray microscope, suitable for imaging at cryogenic temperatures is also disclosed.

  9. OGLE-2003-BLG-262: Finite-Source Effects from a Point-Mass Lens

    NASA Astrophysics Data System (ADS)

    Yoo, Jaiyul; DePoy, D. L.; Gal-Yam, A.; Gaudi, B. S.; Gould, A.; Han, C.; Lipkin, Y.; Maoz, D.; Ofek, E. O.; Park, B.-G.; Pogge, R. W.; Mu-Fun Collaboration; Udalski, A.; Soszyński, I.; Wyrzykowski, Ł.; Kubiak, M.; Szymański, M.; Pietrzyński, G.; Szewczyk, O.; Żebruń, K.; OGLE Collaboration

    2004-03-01

    We analyze OGLE-2003-BLG-262, a relatively short (tE=12.5+/-0.1 day) microlensing event generated by a point-mass lens transiting the face of a K giant source in the Galactic bulge. We use the resulting finite-source effects to measure the angular Einstein radius, θE=195+/-17 μas, and so constrain the lens mass to the FWHM interval 0.08

  10. Contribution of soft lenses of various powers to the optics of a piggy-back system on regular corneas.

    PubMed

    Michaud, Langis; Brazeau, Daniel; Corbeil, Marie-Eve; Forcier, Pierre; Bernard, Pierre-Jean

    2013-12-01

    This study aims to report on the measured in vivo contribution of soft lenses of various powers to the optics of a piggyback system (PBS). This prospective, non-dispensing clinical study was conducted on regular wearers of contact lenses who showed regular corneal profiles. Subjects were masked to the products used. The study involved the use of a spherical soft lens of three different powers in a PBS, used as a carrier for a rigid gas permeable lens. Baseline data were collected and soft lenses were then fitted on both eyes of each subject. Both lenses were assessed for position and movement. Over-refraction was obtained. Soft lens power contribution to the optics (SLPC) of a PBS system was estimated by computing initial ametropia, lacrymal lens, rigid lens powers and over-refraction. A set of data on one eye was kept, for each subject, for statistical analysis. Thirty subjects (12 males, 18 females), aged 24.4 (±4.5) years, were enrolled. The use of plus powered soft lenses enhanced initial RGP lens centration. Once optimal fit was achieved, all lenses showed normal movement. SLPC represented 21.3% of the initial soft lens power when using a -6.00 carrier, and 20.6% for a +6.00. A +0.50 did not contribute to any power induced in the system. These results are generally in accordance with theoretical model developed in the past. On average, except for the low-powered carrier, the use of a spherical soft lens provided 20.9% of its marked power. To achieve better results, the use of a plus-powered carrier is recommended. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. The association of contact lens solution use and Acanthamoeba keratitis

    PubMed Central

    Joslin, Charlotte E.; Tu, Elmer Y.; Shoff, Megan E.; Booton, Gregory C.; Fuerst, Paul A.; McMahon, Timothy T.; Anderson, Robert J.; Dworkin, Mark S.; Sugar, Joel; Davis, Faith G.; Stayner, Leslie T.

    2009-01-01

    Purpose Diagnosis of Acanthamoeba keratitis, a rare but serious corneal infection, has recently increased significantly at the University of Illinois at Chicago (UIC) Cornea Service. The purpose is to investigate Acanthamoeba keratitis risk factors. Design Retrospective case-control study. Methods Setting University, tertiary care hospital. Patients Fifty-five Acanthamoeba keratitis cases with contact lens use were diagnosed between May 1, 2003 and September 15, 2006. Clinic-matched controls with contact lens use were recruited. Subjects completed surveys targeting lens hygiene, contact lens solution use, and water exposure. Main Outcome Measure Acanthamoeba keratitis. Results Thirty-nine (73.6%) cases and 113 (65.3%) controls participated; 38 cases had complete contact lens data. Thirty-five of 38 cases (92.1%) and 47 of 100 controls (47.0%) used soft lenses. Analysis was performed on 30 cases and 39 controls with matched pairs with soft lens use. Exclusive use of AMO Complete MoisturePlus Multi-Purpose Solution was independently associated with Acanthamoeba keratitis in multivariable analysis (55.2% vs. 10.5%; OR, 16.67; 95% CI, 2.11–162.63; p = 0.008). However, 38.8% of cases reported no use of AMO Complete MoisturePlus Multi-Purpose Solution or used it in combination with other solutions. Although not statistically significant, additional hygiene-related variables (solution ‘reuse’, lack of ‘rubbing’, and showering with lenses) suggest a pattern of risk,. Conclusions AMO Complete MoisturePlus Multi-Purpose Solution use is independently associated with Acanthamoeba keratitis among soft contact lens users. However, it does not explain all cases, suggesting additional factors. Further research into environmental risk factors and hygiene practices is warranted, especially considering this is the second outbreak of an atypical, contact lens-related infection. PMID:17588524

  12. Evidence of a glycemic threshold for the formation of pentosidine in diabetic dog lens but not in collagen.

    PubMed

    Nagaraj, R H; Kern, T S; Sell, D R; Fogarty, J; Engerman, R L; Monnier, V M

    1996-05-01

    The relationship between long-term glycemic control and the advanced Maillard reaction was investigated in dura mater collagen and lens proteins from dogs that were diabetic for 5 years. Diabetic dogs were assigned prospectively to good, moderate, and poor glycemic control and maintained by insulin. Biochemical changes were determined at study exit. Mean levels of collagen digestibility by pepsin decreased (NS) whereas collagen glycation (P < 0.001), pentosidine cross-links (P < 0.001), and collagen fluorescence (P = 0.02) increased with increasing mean HbA1 values. Similarly, mean levels of lens crystallin glycation (P < 0.001), fluorescence (P < 0.001), and the specific advanced lens Maillard product 1 (LM-1) (P < 0.001) and pentosidine (P < 0.005) increased significantly with poorer glycemic control. Statistical analysis revealed very high Spearman correlation coefficients between collagen and lens changes. Whereas pentosidine cross-links were significantly elevated in collagen from diabetic dogs with moderate levels of HbA1 (i.e., 8.0 +/- 0.4%), lens pentosidine levels were normal in this group and were elevated (P < 0.001) only in the animals with poor glycemic control (HbA1 = 9.7 +/- 0.6%). Thus, whereas protein glycation and advanced glycation in the extracellular matrix and in the lens are generally related to the level of glycemic control, there is evidence for a tissue-specific glycemic threshold for pentosidine formation, i.e., glycoxidation, in the lens. This threshold may be in part linked to a dramatic acceleration in crystallin glycation with HbA1 values of > 8.0% and/or a loss of lens membrane permeability. This study provides support at the molecular level for the growing concept that glycemic thresholds may be involved in the development of some of the complications in diabetes.

  13. The association of contact lens solution use and Acanthamoeba keratitis.

    PubMed

    Joslin, Charlotte E; Tu, Elmer Y; Shoff, Megan E; Booton, Gregory C; Fuerst, Paul A; McMahon, Timothy T; Anderson, Robert J; Dworkin, Mark S; Sugar, Joel; Davis, Faith G; Stayner, Leslie T

    2007-08-01

    To investigate Acanthamoeba keratitis (AK) risk factors. Diagnosis of AK, a rare but serious corneal infection, has recently increased significantly at the University of Illinois at Chicago (UIC) Cornea Service. Retrospective case-control study. settings: University, tertiary care hospital. patients: Fifty-five AK cases with contact lens use were diagnosed between May 1, 2003 and September 15, 2006. Clinic-matched controls with contact lens use were recruited. Subjects completed surveys targeting lens hygiene, contact lens solution use, and water exposure. main outcome measure: Acanthamoeba keratitis. Thirty-nine (73.6%) cases and 113 (65.3%) controls participated; 38 cases had complete contact lens data. Thirty-five of 38 cases (92.1%) and 47 of 100 controls (47.0%) used soft lenses. Analysis was performed on 30 cases and 39 controls with matched pairs with soft lens use. Exclusive use of Advance Medical Optics (AMO) Complete MoisturePlus Multi-Purpose Solution was independently associated with AK in multivariable analysis (55.2% vs 10.5%; odds ratio [OR], 16.67; 95% confidence interval [CI] 2.11 to 162.63; P = .008). However, 38.8% of cases reported no use of AMO Complete MoisturePlus Multi-Purpose Solution either alone or in combination with other solutions. Although not statistically significant, additional hygiene-related variables (solution "reuse," lack of "rubbing," and showering with lenses) suggest a pattern of risk. AMO Complete MoisturePlus Multi-Purpose Solution use is independently associated with AK among soft contact lens users. However, it does not explain all cases, suggesting additional factors. Further research into environmental risk factors and hygiene practices is warranted, especially considering this is the second outbreak of an atypical, contact lens-related infection.

  14. Short-Term Deposition of PM2.5 Particles on Contact Lens Surfaces: Effect on Oxygen Permeability and Refractive Index.

    PubMed

    Dong, Zhizhang; Ding, Xiaoyan; Li, Yong; Gan, Yifeng; Wang, Yanhui; Xu, Libin; Wang, Yahong; Zhou, Ying; Li, Juan

    2018-05-22

    To identify the deposition of fine (≤2.5 μm diameter) particulate matter (PM) particles (PM 2.5 ) on contact lens surfaces and to investigate the effects of such deposition on the oxygen permeability (OP) and refractive index (RI) of contact lenses. A total of 36 contact lenses, including rigid gas permeable (RGP) lens and soft contact lens (SCL), were investigated. RGP lens (n=12) and SCL (n=12) (experimental group) were incubated in a PM 2.5 solution for 24 h, after which PM 2.5 -treated RGP lens (n=6) and SCL (n=6) were further washed for 1 h in phosphate-buffered saline (PBS). All lenses were examined by field emission scanning electron microscopy. OP and RI of all lenses were measured. Average-sized PM 2.5 particles deposited on RGP contact lens and SCL surfaces after immersion in the PM 2.5 solution were 3.192 ± 1.637 and 2.158 ± 1.187/100 μm 2 , respectively. On RGP lens surfaces, we observed both large (≥2.5 µm diameter) and small (PM 2.5 ) particles. PM 2.5 particles were deposited in diffuse patterns, primarily along the honeycomb structural border of SCL, while no PM 2.5 particles were found in the honeycomb hole of SCL surfaces. Washing in PBS removed the larger PM particles from RGP lens surfaces, but left copious amounts of PM 2.5 particles. In contrast, nearly all PM particles were removed from SCL surfaces after PBS washing. OP values of RGP lens and SCL appeared to be unchanged by PM 2.5 deposition. RI values increased in both RGP lens and SCL groups after PM 2.5 deposition. However, these increases were not statistically significant, suggesting that PM 2.5 deposition itself does not cause fluctuations in contact lens RI. Deposition of PM 2.5 particles on contact lens surfaces varies according to lens material. PM 2.5 particles deposited on SCL, but only large particles on RGP surfaces were able to be removed by washing in PBS and did not appear to alter OP and RI of either lens type.

  15. Changes in the Eye Microbiota Associated with Contact Lens Wearing

    PubMed Central

    Price, Kenneth; Albert, Luong; Dodick, Jack; Park, Lisa

    2016-01-01

    ABSTRACT Wearing contact lenses has been identified as a risk factor for the development of eye conditions such as giant papillary conjunctivitis and keratitis. We hypothesized that wearing contact lenses is associated with changes in the ocular microbiota. We compared the bacterial communities of the conjunctiva and skin under the eye from 58 subjects and analyzed samples from 20 subjects (9 lens wearers and 11 non-lens wearers) taken at 3 time points using a 16S rRNA gene-based sequencing technique (V4 region; Illumina MiSeq). We found that using anesthetic eye drops before sampling decreases the detected ocular microbiota diversity. Compared to those from non-lens wearers, dry conjunctival swabs from lens wearers had more variable and skin-like bacterial community structures (UniFrac; P value = <0.001), with higher abundances of Methylobacterium, Lactobacillus, Acinetobacter, and Pseudomonas and lower abundances of Haemophilus, Streptococcus, Staphylococcus, and Corynebacterium (linear discriminant analysis [LDA] score = >3.0). The results indicate that wearing contact lenses alters the microbial structure of the ocular conjunctiva, making it more similar to that of the skin microbiota. Further research is needed to determine whether the microbiome structure provides less protection from ocular infections. PMID:27006462

  16. Influence of distance between focusing lens and target surface on laser-induced Cu plasma temperature

    NASA Astrophysics Data System (ADS)

    Wang, Ying; Chen, Anmin; Wang, Qiuyun; Sui, Laizhi; Ke, Da; Cao, Sheng; Li, Suyu; Jiang, Yuanfei; Jin, Mingxing

    2018-03-01

    In this study, the influence of distance between the focusing lens and target surface on the plasma temperature of copper induced by a Nd:YAG laser was investigated in the atmosphere. The plasma temperature was calculated by using the Cu (I) lines (510.55 nm, 515.32 nm, and 521.82 nm). The Cu (I) lines were recorded under different lens-to-sample distances and laser pulse energies (15.8 mJ, 27.0 mJ, 43.4 mJ, 59.2 mJ, and 76.8 mJ). The results indicated that the plasma temperature depended strongly on the distance between the focusing lens and target surface. With the increase in the distance, the plasma temperature firstly rose, and then dropped. This could be attributed to the interaction between the tailing of the nanosecond laser pulse and the front portion of the plasma plume, the plasma shielding effect, and the expanding of the plasma. In addition, there was an interesting phenomenon that the plasma temperature and the emission intensity were not completely consistent with the change of the lens-to-sample distance. It is hoped that our research will provide a deeper insight into the underlying physical processes.

  17. Effects of N-acetylcysteine and glutathione ethyl ester drops on streptozotocin-induced diabetic cataract in rats.

    PubMed

    Zhang, Shu; Chai, Fei-Yan; Yan, Hong; Guo, Yong; Harding, J J

    2008-05-12

    To evaluate the effect of N-acetylcysteine (NAC) and glutathione ethyl ester (GSH-EE) eye drops on the progression of diabetic cataract formation induced by streptozotocin (STZ). One hundred and thirty Sprague-Dawley (SD) rats were selected, and diabetes was induced by streptozotocin (65 mg/kg bodyweight) in a single intraperitoneal injection. The control group (group I) received only vehicle. Then, 78 rats with random blood glucose above 14 mmol/l were divided into four groups (group II-V). The drug-treated rats received NAC and GSH-EE eye drops five days before STZ injection. Group I and V animals received sodium phosphate buffer drops (pH 7.4), and those in groups II, III, and IV received 0.01% NAC, 0.05% NAC, and 0.1% GSH-EE drops, respectively. Lens transparency was monitored with a slit lamp biomicroscope and classified into six stages. At the end of four weeks, eight weeks, and 13 weeks, animals were killed and components involved in the pathogenesis of diabetic cataract including thiols (from glutathione and protein), glutathione reductase (GR), catalase (CAT), and glycated proteins were investigated in the lens extracts. Blood glucose, urine glucose, and bodyweight were also determined. The progression in lens opacity induced by diabetes showed a biphasic pattern in which an initial slow increase in the first seven weeks after STZ injection was followed by a rapid increase in the next six weeks. The progression of lens opacity in the treated groups (group II-IV) was slower than that of the untreated group (group V) in the earlier period and especially in the fourth week. There were statistically significant differences between the treated groups and the untreated group (p<0.05). However, these differences became insignificant after the sixth week, and the progression of lens opacification in all diabetic groups became aggravated. The content of thiol (from glutathione and protein), glutathione reductase (GR), and catalase (CAT) were lower in the lens extracts of the diabetic rats four weeks, eight weeks, and 13 weeks after the STZ injection while the levels of thiol and CAT activity were both higher in the treated groups (group II-IV) than in the untreated group (group V) at every stage. However, there was no statistically significant difference (p>0.05). Moreover, the diabetes resulted in an increased level of glycated proteins in both the treated groups and the untreated group, but there was no statistically significant difference between all the diabetic groups (p>0.05). NAC and GSH-EE can slightly inhibit the progression of the diabetic cataract at the earlier stage. They may maintain lens transparency and function by serving as a precursor for glutathione biosynthesis and by protecting sulfhydryl groups from oxidation.

  18. Diffraction limited focusing and routing of gap plasmons by a metal-dielectric-metal lens

    DOE PAGES

    Dennis, Brian S.; Czaplewski, David A.; Haftel, Michael I.; ...

    2015-08-12

    Passive optical elements can play key roles in photonic applications such as plasmonic integrated circuits. Here we experimentally demonstrate passive gap-plasmon focusing and routing in two-dimensions. This is accomplished using a high numerical-aperture metal-dielectric-metal lens incorporated into a planar-waveguide device. Fabrication via metal sputtering, oxide deposition, electron- and focused-ion- beam lithography, and argon ion-milling is reported on in detail. Diffraction-limited focusing is optically characterized by sampling out-coupled light with a microscope. The measured focal distance and full-width-half-maximum spot size agree well with the calculated lens performance. The surface plasmon polariton propagation length is measured by sampling light from multiple out-couplermore » slits.« less

  19. Comparison of eye lens dose on neuroimaging protocols between 16- and 64-section multidetector CT: achieving the lowest possible dose.

    PubMed

    Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L

    2009-02-01

    To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.

  20. Role of pirenoxine in the effects of catalin on in vitro ultraviolet-induced lens protein turbidity and selenite-induced cataractogenesis in vivo

    PubMed Central

    Hu, Chao-Chien; Liao, Jiahn-Haur; Hsu, Kuang-Yang; Lin, I-Lin; Tsai, Ming-Hsuan; Wu, Wen-Hsin; Wei, Tzu-Tang; Huang, Yi-Shiang; Chiu, Shih-Jiuan; Chen, Hsiang-Yin; Wu, Shih-Hsiung

    2011-01-01

    Purpose In this study, we investigated the biochemical pharmacology of pirenoxine (PRX) and catalin under in vitro selenite/calcium- and ultraviolet (UV)-induced lens protein turbidity challenges. The systemic effects of catalin were determined using a selenite-induced cataractogenesis rat model. Methods In vitro cataractogenesis assay systems (including UVB/C photo-oxidation of lens crystallins, calpain-induced proteolysis, and selenite/calcium-induced turbidity of lens crystallin solutions) were used to screen the activity of PRX and catalin eye drop solutions. Turbidity was identified as the optical density measured using spectroscopy at 405 nm. We also determined the in vivo effects of catalin on cataract severity in a selenite-induced cataract rat model. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS–PAGE) was applied to analyze the integrity of crystallin samples. Results PRX at 1,000 μM significantly delayed UVC-induced turbidity formation compared to controls after 4 h of UVC exposure (p<0.05), but not in groups incubated with PRX concentrations of <1,000 μM. Results were further confirmed by SDS–PAGE. The absolute γ-crystallin turbidity induced by 4 h of UVC exposure was ameliorated in the presence of catalin equivalent to 1~100 μM PRX in a concentration-dependent manner. Samples with catalin-formulated vehicle only (CataV) and those containing PRX equivalent to 100 μM had a similar protective effect after 4 h of UVC exposure compared to the controls (p<0.05). PRX at 0.03, 0.1, and 0.3 μM significantly delayed 10 mM selenite- and calcium-induced turbidity formation compared to controls on days 0~4 (p<0.05). Catalin (equivalent to 32, 80, and 100 μM PRX) had an initial protective effect against selenite-induced lens protein turbidity on day 1 (p<0.05). Subcutaneous pretreatment with catalin (5 mg/kg) also statistically decreased the mean cataract scores in selenite-induced cataract rats on post-induction day 3 compared to the controls (1.3±0.2 versus 2.4±0.4; p<0.05). However, catalin (equivalent to up to 100 μM PRX) did not inhibit calpain-induced proteolysis activated by calcium, and neither did 100 μM PRX. Conclusions PRX at micromolar levels ameliorated selenite- and calcium-induced lens protein turbidity but required millimolar levels to protect against UVC irradiation. The observed inhibition of UVC-induced turbidity of lens crystallins by catalin at micromolar concentrations may have been a result of the catalin-formulated vehicle. Transient protection by catalin against selenite-induced turbidity of crystallin solutions in vitro was supported by the ameliorated cataract scores in the early stage of cataractogenesis in vivo by subcutaneously administered catalin. PRX could not inhibit calpain-induced proteolysis activated by calcium or catalin itself, and may be detrimental to crystallins under UVB exposure. Further studies on formulation modifications of catalin and recommended doses of PRX to optimize clinical efficacy by cataract type are warranted. PMID:21850160

  1. Role of pirenoxine in the effects of catalin on in vitro ultraviolet-induced lens protein turbidity and selenite-induced cataractogenesis in vivo.

    PubMed

    Hu, Chao-Chien; Liao, Jiahn-Haur; Hsu, Kuang-Yang; Lin, I-Lin; Tsai, Ming-Hsuan; Wu, Wen-Hsin; Wei, Tzu-Tang; Huang, Yi-Shiang; Chiu, Shih-Jiuan; Chen, Hsiang-Yin; Wu, Shih-Hsiung; Wu, Tzu-Hua

    2011-01-01

    In this study, we investigated the biochemical pharmacology of pirenoxine (PRX) and catalin under in vitro selenite/calcium- and ultraviolet (UV)-induced lens protein turbidity challenges. The systemic effects of catalin were determined using a selenite-induced cataractogenesis rat model. In vitro cataractogenesis assay systems (including UVB/C photo-oxidation of lens crystallins, calpain-induced proteolysis, and selenite/calcium-induced turbidity of lens crystallin solutions) were used to screen the activity of PRX and catalin eye drop solutions. Turbidity was identified as the optical density measured using spectroscopy at 405 nm. We also determined the in vivo effects of catalin on cataract severity in a selenite-induced cataract rat model. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) was applied to analyze the integrity of crystallin samples. PRX at 1,000 μM significantly delayed UVC-induced turbidity formation compared to controls after 4 h of UVC exposure (p<0.05), but not in groups incubated with PRX concentrations of <1,000 μM. Results were further confirmed by SDS-PAGE. The absolute γ-crystallin turbidity induced by 4 h of UVC exposure was ameliorated in the presence of catalin equivalent to 1~100 μM PRX in a concentration-dependent manner. Samples with catalin-formulated vehicle only (CataV) and those containing PRX equivalent to 100 μM had a similar protective effect after 4 h of UVC exposure compared to the controls (p<0.05). PRX at 0.03, 0.1, and 0.3 μM significantly delayed 10 mM selenite- and calcium-induced turbidity formation compared to controls on days 0~4 (p<0.05). Catalin (equivalent to 32, 80, and 100 μM PRX) had an initial protective effect against selenite-induced lens protein turbidity on day 1 (p<0.05). Subcutaneous pretreatment with catalin (5 mg/kg) also statistically decreased the mean cataract scores in selenite-induced cataract rats on post-induction day 3 compared to the controls (1.3±0.2 versus 2.4±0.4; p<0.05). However, catalin (equivalent to up to 100 μM PRX) did not inhibit calpain-induced proteolysis activated by calcium, and neither did 100 μM PRX. PRX at micromolar levels ameliorated selenite- and calcium-induced lens protein turbidity but required millimolar levels to protect against UVC irradiation. The observed inhibition of UVC-induced turbidity of lens crystallins by catalin at micromolar concentrations may have been a result of the catalin-formulated vehicle. Transient protection by catalin against selenite-induced turbidity of crystallin solutions in vitro was supported by the ameliorated cataract scores in the early stage of cataractogenesis in vivo by subcutaneously administered catalin. PRX could not inhibit calpain-induced proteolysis activated by calcium or catalin itself, and may be detrimental to crystallins under UVB exposure. Further studies on formulation modifications of catalin and recommended doses of PRX to optimize clinical efficacy by cataract type are warranted.

  2. 3D on-chip microscopy of optically cleared tissue

    NASA Astrophysics Data System (ADS)

    Zhang, Yibo; Shin, Yoonjung; Sung, Kevin; Yang, Sam; Chen, Harrison; Wang, Hongda; Teng, Da; Rivenson, Yair; Kulkarni, Rajan P.; Ozcan, Aydogan

    2018-02-01

    Traditional pathology relies on tissue biopsy, micro-sectioning, immunohistochemistry and microscopic imaging, which are relatively expensive and labor-intensive, and therefore are less accessible in resource-limited areas. Low-cost tissue clearing techniques, such as the simplified CLARITY method (SCM), are promising to potentially reduce the cost of disease diagnosis by providing 3D imaging and phenotyping of thicker tissue samples with simpler preparation steps. However, the mainstream imaging approach for cleared tissue, fluorescence microscopy, suffers from high-cost, photobleaching and signal fading. As an alternative approach to fluorescence, here we demonstrate 3D imaging of SCMcleared tissue using on-chip holography, which is based on pixel-super-resolution and multi-height phase recovery algorithms to digitally compute the sample's amplitude and phase images at various z-slices/depths through the sample. The tissue clearing procedures and the lens-free imaging system were jointly optimized to find the best illumination wavelength, tissue thickness, staining solution pH, and the number of hologram heights to maximize the imaged tissue volume, minimize the amount of acquired data, while maintaining a high contrast-to-noise ratio for the imaged cells. After this optimization, we achieved 3D imaging of a 200-μm thick cleared mouse brain tissue over a field-of-view of <20mm2 , and the resulting 3D z-stack agrees well with the images acquired with a scanning lens-based microscope (20× 0.75NA). Moreover, the lens-free microscope achieves an order-of-magnitude better data efficiency compared to its lens-based counterparts for volumetric imaging of samples. The presented low-cost and high-throughput lens-free tissue imaging technique enabled by CLARITY can be used in various biomedical applications in low-resource-settings.

  3. Knowledge, usage and barriers associated with contact lens wear in Ghana.

    PubMed

    Abokyi, Samuel; Manuh, George; Otchere, Heinz; Ilechie, Alex

    2017-10-01

    Despite findings that contact lens wear for vision correction provides better quality of life than spectacles, contact lens use in developing countries is low. This study evaluated knowledge, usage and barriers associated with contact lens wear among spectacle wearers in Cape Coast, Ghana. A cross-sectional survey using a structured questionnaire was conducted on an adult population of spectacle wearers to assess their knowledge of contact lens wear for vision correction. The participants were proportionately sampled from three eye clinics in the Cape Coast Metropolis, Ghana. Questionnaires were either self-administered or completed with the help of a research assistant. Of the 422 participants, only 147 (34.8%) knew of contact lens wear for vision correction. The proportion of spectacle wearers reporting history of contact lens wear was 14 (3.3%). Barriers to contact lens wear reported were satisfaction with vision through spectacles 102 (25.0%), lack of adequate information 111 (27.2%), fear of side effects 94 (23.0%) and cost 78 (19.1%). The younger adults and those with higher number of changes of spectacles were more likely to know of contact lenses. Knowledge and usage of contact lenses among spectacle wearers was low. Contact lens education and demonstration of visual performance through fitting of trial contact lenses on potential candidates may help overcome barriers to contact lens wear. Published by Elsevier Ltd.

  4. Dynamic light scattering as an objective noninvasive method in veterinary ophthalmic diagnosis and research

    NASA Astrophysics Data System (ADS)

    Dubin, Stephen; Ansari, Rafat R.; Tulp, Orien; Steinberg, Sheldon; Koch, Seth; DellaVecchia, Michael A.; Cozmi, Mihaela; Victor, Mary

    1999-06-01

    The absence of verbal feedback, available from most human patients, is a major limitation in veterinary diagnosis in general and in the evaluation of ophthalmic lens opacity in particular. A novel compact dynamic light scattering (DLS) instrument, developed at NASA, offers significant mitigation to this limitation. It not only yields objective repeatable non-invasive estimation of lens opacity but also provides insight into the nature of chemical and physical alternations in the lens and other eye structures. For example, DLS measurements of the cataractous lens may be interpreted in terms of alpha crystalline protein size. In contrast to most conventional methods, the examination results are numerical and readily accommodate statistical analysis. We present results of DLS measurements in laboratory rabbits with naphthalene induced cataracts, rodents with genetically conditioned hypertension and/or diabetes mellitus; as well as applications of the DLS method in clinical veterinary patients. Use of DLS in examination of phacoemulsification fluid, urine and other biological materials, and potential applications in ocular toxically will also be discussed.

  5. Silver nanoparticle assisted urine sugar determination using thermal lens spectroscopy

    NASA Astrophysics Data System (ADS)

    Thomas, Lincy; John, Jisha; George, Nibu A.; Kurian, Achamma

    2014-11-01

    Nanotechnology plays a vital role in the development of biosensors by enhancing their sensitivity and performance. In this paper, we report a novel urine sugar sensing method that makes use of the unique properties of silver-nanofluids in combination with the laser induced photothermal lens technique. The thermal lens signal decreases with increase in sugar levels in urine samples, which may be attributed to the enhanced interaction of glucose and conduction electrons of silver-nanoparticles, thereby changing the surface plasmon energy.

  6. Grandmothers raising grandchildren: family structure and well-being in culturally diverse families.

    PubMed

    Goodman, Catherine; Silverstein, Merril

    2002-10-01

    This study addressed well-being of grandmothers raising grandchildren in coparenting and custodial households in a sample of African American, Latino, and White grandmothers. A sample of 1,058 grandmothers was recruited through the schools and media. Grandmothers raising or helping to raise school-aged grandchildren in Los Angeles were interviewed, and analyses were conducted within ethnic groups. African American grandmothers experienced equal well-being in coparenting and custodial families; however, if the stresses related to the parents' problems were removed by statistical control, they favored the custodial arrangement. Latino grandmothers had greater well-being in coparenting families, reflecting a tradition of intergenerational living. White custodial grandmothers experienced somewhat higher levels of affect (positive and negative) but showed no difference in other types of well-being. The cultural lens through which grandparenthood is viewed has a marked impact on the adaptation to custodial or coparenting family structures.

  7. Simple and versatile heterodyne whole-field interferometer for phase optics characterization.

    PubMed

    Silva, D M; Barbosa, E A; Wetter, N U

    2012-10-01

    A wavefront sensor for thermally induced lens and passive lens characterization based on low-coherence digital speckle interferometry was developed and studied. By illuminating the optical setup with two slightly detuned red diode lasers, whole-field contour interference fringes were generated according to the resulting synthetic wavelength. For fringe pattern visualization the optical setup used the light transmitted through a ground glass plate as object beam. The performance of the sensor was investigated and its versatility was demonstrated by measuring the thermal lens induced in an Er-doped glass sample pumped by a 1.76-W diode laser emitting at 976 nm and by evaluating the wavefront distortion introduced by an ophthalmic progressive lens.

  8. Eyeglasses Lens Contour Extraction from Facial Images Using an Efficient Shape Description

    PubMed Central

    Borza, Diana; Darabant, Adrian Sergiu; Danescu, Radu

    2013-01-01

    This paper presents a system that automatically extracts the position of the eyeglasses and the accurate shape and size of the frame lenses in facial images. The novelty brought by this paper consists in three key contributions. The first one is an original model for representing the shape of the eyeglasses lens, using Fourier descriptors. The second one is a method for generating the search space starting from a finite, relatively small number of representative lens shapes based on Fourier morphing. Finally, we propose an accurate lens contour extraction algorithm using a multi-stage Monte Carlo sampling technique. Multiple experiments demonstrate the effectiveness of our approach. PMID:24152926

  9. Diffraction limited focusing and routing of gap plasmons by a metal-dielectric-metal lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, Brian S.; Czaplewski, David A.; Haftel, Michael I.

    2015-01-01

    Passive optical elements can play key roles in photonic applications such as plasmonic integrated circuits. Here we experimentally demonstrate passive gap-plasmon focusing and routing in two-dimensions. This is accomplished using a high numerical-aperture metal-dielectric-metal lens incorporated into a planar-waveguide device. Fabrication via metal sputtering, oxide deposition, electron-and focused-ion-beam lithography, and argon ion-milling is reported on in detail. Diffraction-limited focusing is optically characterized by sampling out-coupled light with a microscope. The measured focal distance and full-width-half-maximum spot size agree well with the calculated lens performance. The surface plasmon polariton propagation length is measured by sampling light from multiple out-coupler slits. (C)more » 2015 Optical Society of America« less

  10. Impact of air-drying lens cases in various locations and positions.

    PubMed

    Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona

    2010-07-01

    To determine the rate and type of microbial contamination when contact lens cases are air-dried in two different positions (face up and face down) and in four different locations (toilet, bathroom, office, and bedroom). Unused contact lens cases (n = 97) were rinsed with 2-ml sterile phosphate buffered saline and then placed on facial tissue paper in different locations: humid (toilet and bathroom) and non-humid (office and bedroom) and air-dried at room temperature. After 24 h, the contact lens cases were collected and sampled for microbial numbers and microbial types identified using standard techniques. The microbial profile and the rate of contamination between different locations and positions were compared. Irrespective of the air-drying location, contact lens cases positioned face up had a significantly higher contamination rate (34/48, 71%) compared with contact lens cases air-dried face down (6/49, 12%) (p < 0.001). For those contact lens cases air-dried face up, there was more contamination when placed in humid environments (toilet and bathroom) than in the non-humid environments (office and bedroom) (p = 0.01). However, the contact lens case contamination rate among various locations was similar when contact lens cases were air-dried face down. Total microorganisms recovered from contact lens cases ranged from 0 to 275 colony forming unit per well. The most frequently recovered microorganisms from the contaminated contact lens cases were coagulase-negative Staphylococci, fungi, and Bacillus spp. Thirty-three percent (13/40) of contact lens cases were contaminated with multiple species. Small numbers of microorganisms from the environment may contaminate contact lens cases while cases are air-dried face up. Cases air-dried in humid environments have higher levels of microbial contamination; this is particularly true when contact lens cases are positioned face up. On the basis of this limited study, we would recommend contact lens cases be air-dried face down.

  11. SNAPshot observations of the largest sample of lensed candidates in the Equatorial and Southern Sky identified with Herschel

    NASA Astrophysics Data System (ADS)

    Marchetti, Lucia

    2017-08-01

    We propose WFC3/IR F110W Snapshot observations of 200 gravitational lensing systems selected using Herschel submm data taken in all the major Herschel extragalactic surveys (over 850 square degrees). This proposal aims to build upon the successful results of our cycle-19 snapshot (ID:12488) to complete the study of the brightest lensed galaxies ever discovered by Herschel in the Equatorial and Southern Sky. Our successful submm-based selection method identifies lensing events at much higher redshift than any other optical-based selection and is independent of the nature of the magnifier. With these data we will (1) characterize the morphology of the lenses and thus statistically determine what populations are responsible for the gravitational optical depth of the Universe, (2) make accurate fits to the lens light profiles disentangling the foreground lenses from the background sources (3) constrain (and in some cases directly detect) the rest-frame optical emission from the background sources providing estimates of the background source extinction, (4) identify the most extreme star-forming galaxies and rare lensing configurations in the Universe providing the best candidates for future ALMA follow-up, (5) measure the evolution of both the lens mass-density profile, constraing their assembly history, and the lens IMF. This HST program is well-timed with our on-going large spectroscopic program with SALT (3-year program, started in late 2015). This synergy guarantees the timely spectroscopic characterization of our targets securing a long-lasting legacy for this program.

  12. Quantitative evaluation of light scattering intensities of the crystalline lens for radiation related minimal change in interventional radiologists: a cross-sectional pilot study.

    PubMed

    Abe, Toshi; Furui, Shigeru; Sasaki, Hiroshi; Sakamoto, Yasuo; Suzuki, Shigeru; Ishitake, Tatsuya; Terasaki, Kinuyo; Kohtake, Hiroshi; Norbash, Alexander M; Behrman, Richard H; Hayabuchi, Naofumi

    2013-03-01

    To evaluate low-dose X-ray radiation effects on the eye by measuring the amount of light scattering in specific regions of the lens, we compared exposed subjects (interventional radiologists) with unexposed subjects (employees of medical service companies), as a pilot study. According to numerous exclusionary rules, subjects with confounding variables contributing to cataract formation were excluded. Left eye examinations were performed on 68 exposed subjects and 171 unexposed subjects. The eye examinations consisted of an initial screening examination, followed by Scheimpflug imaging of the lens using an anterior eye segment analysis system. The subjects were assessed for the quantity of light scattering intensities found in each of the six layers of the lens. Multiple stepwise regression analyses were performed with the stepwise regression for six variables: age, radiation exposure, smoking, drinking, wearing glasses and workplace. In addition, an age-matched comparison between exposed and unexposed subjects was performed. Minimal increased light scattering intensity in the posterior subcapsular region showed statistical significance. Our results indicate that occupational radiation exposure in interventional radiologists may affect the posterior subcapsular region of the lens. Since by its very nature this retrospective study had many limitations, further well-designed studies concerning minimal radiation-related lens changes should be carried out in a low-dose exposure group.

  13. Deposition of lipid, protein, and secretory phospholipase A2 on hydrophilic contact lenses.

    PubMed

    Mochizuki, Hiroshi; Yamada, Masakazu; Hatou, Shin; Kawashima, Motoko; Hata, Seiichiro

    2008-01-01

    Recent studies have shown that low tear phospholipid levels are associated with tear film instability in hydrophilic contact lens wearers. The concentration of secretory phospholipase A2 (sPLA2), the enzyme that hydrolyzes phospholipids, in tears is known to exceed the levels found in serum by four orders of magnitude. This study was performed to determine the levels of sPLA2 from the deposition on two different frequent-replacement contact lens materials. Polymacon and etafilcon A contact lenses worn for 2 weeks by 16 experienced contact lens wearers were used for the analysis. Total lipids were determined by the sulfo-phospho-vanillin reaction. Phospholipids in lipid extracts were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Total protein was measured by bicinchoninic acid analysis. Double-antibody sandwich enzyme-linked immunosorbent assay was used to determine sPLA2 concentrations. Total lipid deposition was found to be greater in the polymacon group (66.3+/-16.3 microg/lens) than in the etafilcon A group, although phospholipids were not detected in either group. The etafilcon A group had greater deposition of protein (3.7+/-0.7 mg/lens) than the polymacon group had. The etafilcon A group deposited statistically significantly more group IIa sPLA2 (1.1+/-0.3 microg/lens) than the polymacon group (0.07+/-0.04 microg/lens) did (P<0.001). There was a significant difference in the lipid and protein deposition profiles in the two lenses tested. A significant amount of sPLA2 in the deposition on contact lenses may play a role in tear film instability in hydrophilic contact lens wearers.

  14. A SEARCH FOR STELLAR-MASS BLACK HOLES VIA ASTROMETRIC MICROLENSING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, J. R.; Sinukoff, E.; Ofek, E. O.

    While dozens of stellar-mass black holes (BHs) have been discovered in binary systems, isolated BHs have eluded detection. Their presence can be inferred when they lens light from a background star. We attempt to detect the astrometric lensing signatures of three photometrically identified microlensing events, OGLE-2011-BLG-0022, OGLE-2011-BLG-0125, and OGLE-2012-BLG-0169 (OB110022, OB110125, and OB120169), located toward the Galactic Bulge. These events were selected because of their long durations, which statistically favors more massive lenses. Astrometric measurements were made over one to two years using laser-guided adaptive optics observations from the W. M. Keck Observatory. Lens model parameters were first constrained bymore » the photometric light curves. The OB120169 light curve is well fit by a single-lens model, while both OB110022 and OB110125 light curves favor binary lens models. Using the photometric fits as prior information, no significant astrometric lensing signal was detected and all targets were consistent with linear motion. The significant lack of astrometric signal constrains the lens mass of OB110022 to 0.05–1.79 M {sub ⊙} in a 99.7% confidence interval, which disfavors a BH lens. Fits to OB110125 yielded a reduced Einstein crossing time and insufficient observations during the peak, so no mass limits were obtained. Two degenerate solutions exist for OB120169, which have a lens mass between 0.2–38.8 M {sub ⊙} and 0.4–39.8 M {sub ⊙} for a 99.7% confidence interval. Follow-up observations of OB120169 will further constrain the lens mass. Based on our experience, we use simulations to design optimal astrometric observing strategies and show that with more typical observing conditions the detection of BHs is feasible.« less

  15. A Simple Device for Lens-to-Sample Distance Adjustment in Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Cortez, Juliana; Farias Filho, Benedito B; Fontes, Laiane M; Pasquini, Celio; Raimundo, Ivo M; Pimentel, Maria Fernanda; de Souza Lins Borba, Flávia

    2017-04-01

    A simple device based on two commercial laser pointers is described to assist in the analysis of samples that present uneven surfaces and/or irregular shapes using laser-induced breakdown spectroscopy (LIBS). The device allows for easy positioning of the sample surface at a reproducible distance from the focusing lens that conveys the laser pulse to generate the micro-plasma in a LIBS system, with reproducibility better than ±0.2 mm. In this way, fluctuations in the fluence (J cm -2 ) are minimized and the LIBS analytical signals can be obtained with a better precision even when samples with irregular surfaces are probed.

  16. 3D imaging of optically cleared tissue using a simplified CLARITY method and on-chip microscopy

    PubMed Central

    Zhang, Yibo; Shin, Yoonjung; Sung, Kevin; Yang, Sam; Chen, Harrison; Wang, Hongda; Teng, Da; Rivenson, Yair; Kulkarni, Rajan P.; Ozcan, Aydogan

    2017-01-01

    High-throughput sectioning and optical imaging of tissue samples using traditional immunohistochemical techniques can be costly and inaccessible in resource-limited areas. We demonstrate three-dimensional (3D) imaging and phenotyping in optically transparent tissue using lens-free holographic on-chip microscopy as a low-cost, simple, and high-throughput alternative to conventional approaches. The tissue sample is passively cleared using a simplified CLARITY method and stained using 3,3′-diaminobenzidine to target cells of interest, enabling bright-field optical imaging and 3D sectioning of thick samples. The lens-free computational microscope uses pixel super-resolution and multi-height phase recovery algorithms to digitally refocus throughout the cleared tissue and obtain a 3D stack of complex-valued images of the sample, containing both phase and amplitude information. We optimized the tissue-clearing and imaging system by finding the optimal illumination wavelength, tissue thickness, sample preparation parameters, and the number of heights of the lens-free image acquisition and implemented a sparsity-based denoising algorithm to maximize the imaging volume and minimize the amount of the acquired data while also preserving the contrast-to-noise ratio of the reconstructed images. As a proof of concept, we achieved 3D imaging of neurons in a 200-μm-thick cleared mouse brain tissue over a wide field of view of 20.5 mm2. The lens-free microscope also achieved more than an order-of-magnitude reduction in raw data compared to a conventional scanning optical microscope imaging the same sample volume. Being low cost, simple, high-throughput, and data-efficient, we believe that this CLARITY-enabled computational tissue imaging technique could find numerous applications in biomedical diagnosis and research in low-resource settings. PMID:28819645

  17. [Bioinorganic chemical composition of the lens and methods of its investigation].

    PubMed

    Avetisov, S E; Novikov, I A; Pakhomova, N A; Motalov, V G

    2018-01-01

    Bioinorganic chemical composition of the lens of human and experimental animals (cows, dogs, rats, rabbits) have been analyzed in various studies. In most cases, the studies employed different methods to determine the gross (total) composition of chemical elements and their concentrations in the examined samples. Less frequently, they included an assessment of the distribution of chemical elements in the lens and correlation of their concentration with its morphological changes. Chemical elements from all groups (series) of the periodic classification system were discovered in the lens substance. Despite similar investigation methods, different authors obtained contradicting results on the chemical composition of the lens. This article presents data suggesting possible correlation between inorganic chemical elements in the lens substance with the development and formation of lenticular opacities. All currently employed methods are known to only analyze limited number of select chemical elements in the tissues and do not consider the whole range of elements that can be analyzed with existing technology; furthermore, the majority of studies are conducted on the animal model lens. Therefore, it is feasible to continue the development of the chemical microanalysis method by increasing the sensitivity of Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEM/EDS) with the purpose of assessing the gross chemical composition and distribution of the elements in the lens substance, as well as revealing possible correlation between element concentration and morphological changes in the lens.

  18. Amyloid β1-43 Accumulates in the Lens Epithelium of Cortical Opacification in Japanese Patients.

    PubMed

    Nagai, Noriaki; Mano, Yu; Otake, Hiroko; Shibata, Teppei; Kubo, Eri; Sasaki, Hiroshi

    2017-06-01

    We investigated the accumulation of amyloid β (Aβ1-40, Aβ1-42, Aβ1-43) in the lens epithelium of patients with opacification of five different types (cortical cataract [COR]; nuclear cataract [NUC]; posterior subcapsular cataract [PSC]; retrodots [RD]; and water clefts [WC]). Samples were collected from Japanese patients taken during cataract surgery; Aβ levels and mRNA expression were determined by ELISA and a real-time RT-PCR method, respectively. Levels of Aβ1-40 and Aβ1-42 in the lens epithelium of patients with COR, NUC, PSC, RD, and WC showed no significant differences in comparison with transparent lens epithelium. Levels of Aβ1-43 in the lens epithelium of patients with PSC and WC were not detected, and NUC and RD were slightly elevated. In contrast to the results in these cataract types, high Aβ1-43 levels were observed in the lens epithelium of patients with COR, and a close relationship was observed between Aβ1-43 levels and the degree of lens opacification (R = 0.8229, n = 6). The levels of Aβ1-43 were also higher in the lens epithelium of patients with mixed-cataract showing cortical opacification, and the Aβ1-43 levels in the lens epithelium of mixed-cataract patients with cortical opacification was significantly higher than in that of mixed-cataract patients without cortical opacification. In addition, the level of an amyloid precursor protein mRNA in the lens epithelium of mixed-cataract patients with cortical opacification was significantly higher than in transparent lens and mixed-cataract patients without cortical opacification. We found high levels of Aβ1-43 accumulation in the lens epithelium of Japanese patients with cortical opacification.

  19. Rapid Assessment of the Ce-Co-Fe-Cu System for Permanent Magnetic Applications

    NASA Astrophysics Data System (ADS)

    Meng, F.; Chaudhary, R. P.; Gandha, K.; Nlebedim, I. C.; Palasyuk, A.; Simsek, E.; Kramer, M. J.; Ott, R. T.

    2018-06-01

    This work focuses on the rapid synthesis and characterization of quaternary Ce(CoFeCu)5 alloy libraries to assess their potential viability as permanent magnets. Arrays of bulk specimens with controlled compositions were synthesized via laser engineered net shaping (LENS) by feeding different ratios of alloy powders into a melt pool created by a laser. Based on the assessment of the magnetic properties of the LENS printed samples, arc-melted and cast ingots were prepared with varying Fe (5-20 at.%) and Co (60-45 at.%) compositions while maintaining constant Ce (16 at.%) and Cu (19 at.%) content. The evolution of the microstructure and phases with varying chemical compositions and their dependence on magnetic properties are analyzed in as-cast and heat-treated samples. In both the LENS printed and cast samples, we find the best magnetic properties correspond to a predominantly single-phase Ce(CoFeCu)5 microstructure in which high coercivity ( H c > 10 kOe) can be achieved without any microstructural refinement.

  20. Rapid Assessment of the Ce-Co-Fe-Cu System for Permanent Magnetic Applications

    NASA Astrophysics Data System (ADS)

    Meng, F.; Chaudhary, R. P.; Gandha, K.; Nlebedim, I. C.; Palasyuk, A.; Simsek, E.; Kramer, M. J.; Ott, R. T.

    2018-04-01

    This work focuses on the rapid synthesis and characterization of quaternary Ce(CoFeCu)5 alloy libraries to assess their potential viability as permanent magnets. Arrays of bulk specimens with controlled compositions were synthesized via laser engineered net shaping (LENS) by feeding different ratios of alloy powders into a melt pool created by a laser. Based on the assessment of the magnetic properties of the LENS printed samples, arc-melted and cast ingots were prepared with varying Fe (5-20 at.%) and Co (60-45 at.%) compositions while maintaining constant Ce (16 at.%) and Cu (19 at.%) content. The evolution of the microstructure and phases with varying chemical compositions and their dependence on magnetic properties are analyzed in as-cast and heat-treated samples. In both the LENS printed and cast samples, we find the best magnetic properties correspond to a predominantly single-phase Ce(CoFeCu)5 microstructure in which high coercivity (H c > 10 kOe) can be achieved without any microstructural refinement.

  1. High-contrast 3D image acquisition using HiLo microscopy with an electrically tunable lens

    NASA Astrophysics Data System (ADS)

    Philipp, Katrin; Smolarski, André; Fischer, Andreas; Koukourakis, Nektarios; Stürmer, Moritz; Wallrabe, Ulricke; Czarske, Jürgen

    2016-04-01

    We present a HiLo microscope with an electrically tunable lens for high-contrast three-dimensional image acquisition. HiLo microscopy combines wide field and speckled illumination images to create optically sectioned images. Additionally, the depth-of-field is not fixed, but can be adjusted between wide field and confocal-like axial resolution. We incorporate an electrically tunable lens in the HiLo microscope for axial scanning, to obtain three-dimensional data without the need of moving neither the sample nor the objective. The used adaptive lens consists of a transparent polydimethylsiloxane (PDMS) membrane into which an annular piezo bending actuator is embedded. A transparent fluid is filled between the membrane and the glass substrate. When actuated, the piezo generates a pressure in the lens which deflects the membrane and thus changes the refractive power. This technique enables a large tuning range of the refractive power between 1/f = (-24 . . . 25) 1/m. As the NA of the adaptive lens is only about 0.05, a fixed high-NA lens is included in the setup to provide high resolution. In this contribution, the scan properties and capabilities of the tunable lens in the HiLo microscope are analyzed. Eventually, exemplary measurements are presented and discussed.

  2. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    PubMed

    Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  3. Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens

    PubMed Central

    Fletcher, Daniel A.

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples. PMID:24854188

  4. Dielectric studies of the paracetamol-lenticular tissue interactions.

    PubMed

    Marzec, E; Olszewski, J; Grześkowiak, E; Kamińska, A; Bienert, A; Iwanik, K

    2011-05-01

    This paper reports on the effect of paracetamol on the dielectric behavior of the rabbit lens. Measurements were performed over the frequency range of 100 Hz-100 kHz in air and at the temperature of 35°C. The frequency dependencies of the relative permittivity and dielectric loss for the control and paracetamol-control lenses are described in terms of a power-low, Debye and Cole-Cole relations. The effect of paracetamol on the dielectric properties of the lens is visible in the lower values of the relative permittivity than those for the control sample at the same frequency. In addition, the relaxations around 18 and 46 kHz for the paracetamol-control lens are shifted to lower frequencies compared with the control lens. The results of this work indicate that the present method is useful in detection of the lens toxicity elicited by overdoses of paracetamol in animal. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. The CASTLES Imaging Survey of Gravitational Lenses

    NASA Astrophysics Data System (ADS)

    Peng, C. Y.; Falco, E. E.; Lehar, J.; Impey, C. D.; Kochanek, C. S.; McLeod, B. A.; Rix, H.-W.

    1997-12-01

    The CASTLES survey (Cfa-Arizona-(H)ST-Lens-Survey) is imaging most known small-separation gravitational lenses (or lens candidates), using the NICMOS camera (mostly H-band) and the WFPC2 (V and I band) on HST. To date nearly half of the IR imaging survey has been completed. The main goals are: (1) to search for lens galaxies where none have been directly detected so far; (2) obtain photometric redshift estimates (VIH) for the lenses where no spectroscopic redshifts exist; (3) study and model the lens galaxies in detail, in part to study the mass distribution within them, in part to identify ``simple" systems that may permit accurate time delay estimates for H_0; (3) measure the M/L evolution of the sample of lens galaxies with look-back time (to z ~ 1); (4) determine directly which fraction of sources are lensed by ellipticals vs. spirals. We will present the survey specifications and the images obtained so far.

  6. LensFlow: A Convolutional Neural Network in Search of Strong Gravitational Lenses

    NASA Astrophysics Data System (ADS)

    Pourrahmani, Milad; Nayyeri, Hooshang; Cooray, Asantha

    2018-03-01

    In this work, we present our machine learning classification algorithm for identifying strong gravitational lenses from wide-area surveys using convolutional neural networks; LENSFLOW. We train and test the algorithm using a wide variety of strong gravitational lens configurations from simulations of lensing events. Images are processed through multiple convolutional layers that extract feature maps necessary to assign a lens probability to each image. LENSFLOW provides a ranking scheme for all sources that could be used to identify potential gravitational lens candidates by significantly reducing the number of images that have to be visually inspected. We apply our algorithm to the HST/ACS i-band observations of the COSMOS field and present our sample of identified lensing candidates. The developed machine learning algorithm is more computationally efficient and complimentary to classical lens identification algorithms and is ideal for discovering such events across wide areas from current and future surveys such as LSST and WFIRST.

  7. Contact lens deposits, adverse responses, and clinical ocular surface parameters.

    PubMed

    Zhao, Zhenjun; Naduvilath, Thomas; Flanagan, Judith L; Carnt, Nicole A; Wei, Xiaojia; Diec, Jennie; Evans, Vicki; Willcox, Mark D P

    2010-09-01

    To correlate clinical responses during contact lens wear with the amount of protein or cholesterol extracted from lenses after wear. Clinical parameters, including adverse response rates and corneal staining, and symptomatology rating during lens wear were collected from a series of clinical tests comprising four different silicone hydrogel lenses with four different multipurpose solutions. To test for correlates, the amount of total protein or cholesterol extracted from lenses after daily wear were compared statistically to clinical parameters. The amount of protein (p = 0.008) or cholesterol (p = 0.01) extracted from lenses was higher for those subjects who showed solution-induced corneal staining. Amount of protein extracted was correlated (p < 0.01) with conjunctival staining (R = -0.23), lens front surface wetting (r = 0.14), and lens fit tightness (R = -0.20). These clinical parameters accounted for 48% of lens protein deposition. The amount of cholesterol extracted from lenses was much more weakly associated with clinical variables. Amount of protein or cholesterol extracted from lenses was not associated with the production of any corneal infiltrative or mechanical adverse event during wear and was only very weakly correlated with insertion comfort of lenses. These results suggest that there may be no physiologically relevant consequence of cholesterol depositing on silicone hydrogel lenses. The amount of protein that deposits onto silicone hydrogel lenses during wear may have more affect on lens performance on-eye. However, the correlations were generally small and may still not indicate any causative relevant physiological response. Further work is required to determine whether there is any direct causative effect to support these correlative findings.

  8. Objective measurement of accommodative biometric changes using ultrasound biomicroscopy

    PubMed Central

    Ramasubramanian, Viswanathan; Glasser, Adrian

    2015-01-01

    PURPOSE To demonstrate that ultrasound biomicroscopy (UBM) can be used for objective quantitative measurements of anterior segment accommodative changes. SETTING College of Optometry, University of Houston, Houston, Texas, USA. DESIGN Prospective cross-sectional study. METHODS Anterior segment biometric changes in response to 0 to 6.0 diopters (D) of accommodative stimuli in 1.0 D steps were measured in eyes of human subjects aged 21 to 36 years. Imaging was performed in the left eye using a 35 MHz UBM (Vumax) and an A-scan ultrasound (A-5500) while the right eye viewed the accommodative stimuli. An automated Matlab image-analysis program was developed to measure the biometry parameters from the UBM images. RESULTS The UBM-measured accommodative changes in anterior chamber depth (ACD), lens thickness, anterior lens radius of curvature, posterior lens radius of curvature, and anterior segment length were statistically significantly (P < .0001) linearly correlated with accommodative stimulus amplitudes. Standard deviations of the UBM-measured parameters were independent of the accommodative stimulus demands (ACD 0.0176 mm, lens thickness 0.0294 mm, anterior lens radius of curvature 0.3350 mm, posterior lens radius of curvature 0.1580 mm, and anterior segment length 0.0340 mm). The mean difference between the A-scan and UBM measurements was −0.070 mm for ACD and 0.166 mm for lens thickness. CONCLUSIONS Accommodating phakic eyes imaged using UBM allowed visualization of the accommodative response, and automated image analysis of the UBM images allowed reliable, objective, quantitative measurements of the accommodative intraocular biometric changes. PMID:25804579

  9. Testing safety eyewear: how frame and lens design affect lens retention.

    PubMed

    McMahon, Janice M; Beckerman, Stephen

    2007-02-01

    The aim of this study was to determine the role that frame and lens design play in lens retention during high-impact testing of safety eyewear that advertises conformance to the performance-based ANSI Z87.1-2003 standard. A total of 75 Z87 safety eyeglass frames (3 each of 25 frame models) were used in this study, procured from 5 of the leading U.S. safety frame manufacturers. Frames were fitted by an independent laboratory with 2.0-mm plano polycarbonate lenses in compliance with ANSI Z87.1-2003. Finished spectacles were sent to a subsequent laboratory testing facility where each frame was subjected to both high-mass and oblique-incidence high-velocity impacts to determine frame characteristics that were most highly associated with testing failure. Among the frame and lens parameters that were considered in this analysis were the A and B dimensions, effective diameter, distance between lenses, bridge type, frame material, bevel type, and frame cost. Certain variables were controlled for by maintaining consistency among all spectacle pairs, e.g., lens prescription, center thickness, and edge thickness. Multiple logistic regression was used to control potential confounding variables and to develop the best combination of them for predictive value. Of 25 separate frame models assessed, 10 passed both high-mass and high-velocity impact testing, i.e., none of the 3 frame/lens samples failed. Of the models that failed, 13 failures were caused by high-velocity testing, 1 by high-mass testing, and 1 failed both high-mass and high-velocity testing. None of the 15 spectacles with the SprinGuardtrade mark (Hilco, Plainville, Massachusetts) bevel design failed, although these were proprietary to 1 manufacturer and included only 5 frame models. Two spectacle designs (6 individual frames) incorporated an inverted bevel design of which 3 of the frames failed impact testing. Controlling for drop ball velocity among the 54 remaining standard "V" bevel spectacle pairs, the odds of failure were about 8 to 9 times higher for metal frames than Zylonite frames (odds ratio [OR], 8.5; 95% confidence interval [CI], 1.4 to 52.3; P = 0.02), and the odds of failure were about 4 times higher for lens effective diameters of less than 50 mm than for lens effective diameters more than 50 mm (OR, 4.1; 95% CI, 1.2 to 14.8; P = 0.03). Among our sample of safety spectacles, failure from high-mass impact resistance testing rarely occurred. No spectacles with the SprinGuard bevel design failed in our analysis, but this was limited to a small sample size from a single manufacturer. Among our sample of 54 spectacle pairs with a v-bevel design, metal frame material and an effective diameter of less than 50 mm were the strongest predictors of failure relative to high-velocity impact testing with a 45 degrees temporal angle projectile.

  10. Distortion Correction of OCT Images of the Crystalline Lens: GRIN Approach

    PubMed Central

    Siedlecki, Damian; de Castro, Alberto; Gambra, Enrique; Ortiz, Sergio; Borja, David; Uhlhorn, Stephen; Manns, Fabrice; Marcos, Susana; Parel, Jean-Marie

    2012-01-01

    Purpose To propose a method to correct Optical Coherence Tomography (OCT) images of posterior surface of the crystalline lens incorporating its gradient index (GRIN) distribution and explore its possibilities for posterior surface shape reconstruction in comparison to existing methods of correction. Methods 2-D images of 9 human lenses were obtained with a time-domain OCT system. The shape of the posterior lens surface was corrected using the proposed iterative correction method. The parameters defining the GRIN distribution used for the correction were taken from a previous publication. The results of correction were evaluated relative to the nominal surface shape (accessible in vitro) and compared to the performance of two other existing methods (simple division, refraction correction: assuming a homogeneous index). Comparisons were made in terms of posterior surface radius, conic constant, root mean square, peak to valley and lens thickness shifts from the nominal data. Results Differences in the retrieved radius and conic constant were not statistically significant across methods. However, GRIN distortion correction with optimal shape GRIN parameters provided more accurate estimates of the posterior lens surface, in terms of RMS and peak values, with errors less than 6μm and 13μm respectively, on average. Thickness was also more accurately estimated with the new method, with a mean discrepancy of 8μm. Conclusions The posterior surface of the crystalline lens and lens thickness can be accurately reconstructed from OCT images, with the accuracy improving with an accurate model of the GRIN distribution. The algorithm can be used to improve quantitative knowledge of the crystalline lens from OCT imaging in vivo. Although the improvements over other methods are modest in 2-D, it is expected that 3-D imaging will fully exploit the potential of the technique. The method will also benefit from increasing experimental data of GRIN distribution in the lens of larger populations. PMID:22466105

  11. Distortion correction of OCT images of the crystalline lens: gradient index approach.

    PubMed

    Siedlecki, Damian; de Castro, Alberto; Gambra, Enrique; Ortiz, Sergio; Borja, David; Uhlhorn, Stephen; Manns, Fabrice; Marcos, Susana; Parel, Jean-Marie

    2012-05-01

    To propose a method to correct optical coherence tomography (OCT) images of posterior surface of the crystalline lens incorporating its gradient index (GRIN) distribution and explore its possibilities for posterior surface shape reconstruction in comparison to existing methods of correction. Two-dimensional images of nine human lenses were obtained with a time-domain OCT system. The shape of the posterior lens surface was corrected using the proposed iterative correction method. The parameters defining the GRIN distribution used for the correction were taken from a previous publication. The results of correction were evaluated relative to the nominal surface shape (accessible in vitro) and compared with the performance of two other existing methods (simple division, refraction correction: assuming a homogeneous index). Comparisons were made in terms of posterior surface radius, conic constant, root mean square, peak to valley, and lens thickness shifts from the nominal data. Differences in the retrieved radius and conic constant were not statistically significant across methods. However, GRIN distortion correction with optimal shape GRIN parameters provided more accurate estimates of the posterior lens surface in terms of root mean square and peak values, with errors <6 and 13 μm, respectively, on average. Thickness was also more accurately estimated with the new method, with a mean discrepancy of 8 μm. The posterior surface of the crystalline lens and lens thickness can be accurately reconstructed from OCT images, with the accuracy improving with an accurate model of the GRIN distribution. The algorithm can be used to improve quantitative knowledge of the crystalline lens from OCT imaging in vivo. Although the improvements over other methods are modest in two dimension, it is expected that three-dimensional imaging will fully exploit the potential of the technique. The method will also benefit from increasing experimental data of GRIN distribution in the lens of larger populations.

  12. Modelling the line-of-sight contribution in substructure lensing

    NASA Astrophysics Data System (ADS)

    Despali, Giulia; Vegetti, Simona; White, Simon D. M.; Giocoli, Carlo; van den Bosch, Frank C.

    2018-04-01

    We investigate how Einstein rings and magnified arcs are affected by small-mass dark-matter haloes placed along the line of sight to gravitational lens systems. By comparing the gravitational signature of line-of-sight haloes with that of substructures within the lensing galaxy, we derive a mass-redshift relation that allows us to rescale the detection threshold (i.e. lowest detectable mass) for substructures to a detection threshold for line-of-sight haloes at any redshift. We then quantify the line-of-sight contribution to the total number density of low-mass objects that can be detected through strong gravitational lensing. Finally, we assess the degeneracy between substructures and line-of-sight haloes of different mass and redshift to provide a statistical interpretation of current and future detections, with the aim of distinguishing between cold dark matter and warm dark matter. We find that line-of-sight haloes statistically dominate with respect to substructures, by an amount that strongly depends on the source and lens redshifts, and on the chosen dark-matter model. Substructures represent about 30 percent of the total number of perturbers for low lens and source redshifts (as for the SLACS lenses), but less than 10 per cent for high-redshift systems. We also find that for data with high enough signal-to-noise ratio and angular resolution, the non-linear effects arising from a double-lens-plane configuration are such that one is able to observationally recover the line-of-sight halo redshift with an absolute error precision of 0.15 at the 68 per cent confidence level.

  13. Clear lens phacoemulsification in Alport syndrome: refractive results and electron microscopic analysis of the anterior lens capsule.

    PubMed

    Bayar, Sezin Akca; Pinarci, Eylem Yaman; Karabay, Gulten; Akman, Ahmet; Oto, Sibel; Yilmaz, Gursel

    2014-01-01

    To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group. Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were included in this study. Clear corneal phacoemulsification and intraocular foldable lens implantation was performed in eyes with indeterminate refractive errors and/or poor visual acuity and anterior capsule samples were analyzed with electron microscopy. All patients had a history of hereditary nephritis and/or deafness as systemic involvement. Ophthalmologic examination revealed anterior lenticonus with high myopia and/or irregular astigmatism in all patients. The mean best-corrected visual acuity (BCVA) was 0.67 ± 0.17 logMAR (range 1.0-0.4) preoperatively and 0.17 ± 0.08 logMAR (range 0.3-0.0) postoperatively. Postoperative refractive lenticular astigmatism dramatically decreased and no ocular complications arose during the follow-up period. Transmission electron microscopic analysis of the lens capsules supported the diagnosis of Alport syndrome. Clear lens phacoemulsification and foldable intraocular lens implantation is a safe and effective therapeutic choice for the management of uncorrectable refractive errors and low visual acuity due to anterior lenticonus in patients with Alport syndrome.

  14. Investigation of the mixing efficiency of a chaotic micromixer using thermal lens spectrometry.

    PubMed

    Ghaleb, Khalil Abbas; Stephan, Khaled; Pittet, Patrick; Ferrigno, Rosaria; Georges, Joseph

    2006-05-01

    This work investigates the efficiency of a chaotic micromixer using thermal lens spectrometry. The outlet of the mixing device was connected to a thermal lens detection head integrating the probe beam optical fibers and the sample capillary. The chaotic micromixer consisted of a Y-shaped poly(dimethylsiloxane) (PDMS) microchip in which ribbed herringbone microstructures were etched on the floor of the main channel. Due to the solvent composition dependence of the thermal lens response, the photothermal method was shown to be highly sensitive to nonhomogeneous mixing compared to fluorescence detection. The apparatus was applied to the determination of Fe2+ with 1,10-phenanthroline using flow injection analysis; a limit of detection of 11 microg L(-1) of iron was obtained.

  15. Time-specific blockade of PDGFR with Imatinib (Glivec®) causes cataract and disruption of lens fiber cells in neonatal mice.

    PubMed

    Zhou, Yin-Pin; He, Yang-Tao; Chen, Cheng-Li; Ji, Jun; Niu, Jian-Qin; Wang, Han-Zhi; Li, Shi-Feng; Huang, Lan; Mei, Feng

    2011-03-01

    This study aimed at investigating the response of lens epithelial cells in postnatal mice to Imatinib (Glivec®, a potent inhibitor of platelet-derived growth factor receptor (PDGFR)) treatment. Mouse eyes were sampled 10 days after administration of Imatinib (0.5 mg·g(-1)·day(-1)) for 3 days, at either 7, 14, or 21 days postpartum. Structural changes of lens were revealed by routine H.E. staining. Levels of proliferation and apoptosis were revealed by BrdU incorporation and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay, respectively, and immunofluorescent staining with anti-PDGFRα antibody was carried out on the sections of eyeball. PDGFRα and p-PDGFRαprotein levels were evaluated by Western blot. Our results indicated that administration of Imatinib led to blockade of PDGFR signaling. Formation of cataracts was found only in those mice where treatment started from 7 days postpartum (P7), but was not observed in those samples from P14 nor P21. Fiber cells were disorganized in cataract lens core as observed histologically, and migration of epithelial cells was also inhibited. No apoptosis was detected with the TUNEL method. Our results indicated blockade of PDGFR at the neonatal stage (P7) would lead to cataracts and lens fiber cells disorganization, suggesting that PDGFR signaling plays a time-specific and crucial role in the postnatal development of lens in the mouse, and also may provide a new approach to produce a congenital cataract animal model.

  16. Anterior segment and retinal OCT imaging with simplified sample arm using focus tunable lens technology (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Grulkowski, Ireneusz; Karnowski, Karol; Ruminski, Daniel; Wojtkowski, Maciej

    2016-03-01

    Availability of the long-depth-range OCT systems enables comprehensive structural imaging of the eye and extraction of biometric parameters characterizing the entire eye. Several approaches have been developed to perform OCT imaging with extended depth ranges. In particular, current SS-OCT technology seems to be suited to visualize both anterior and posterior eye in a single measurement. The aim of this study is to demonstrate integrated anterior segment and retinal SS-OCT imaging using a single instrument, in which the sample arm is equipped with the electrically tunable lens (ETL). ETL is composed of the optical liquid confined in the space by an elastic polymer membrane. The shape of the membrane, electrically controlled by a specific ring, defines the radius of curvature of the lens surface, thus it regulates the power of the lens. ETL can be also equipped with additional offset lens to adjust the tuning range of the optical power. We characterize the operation of the tunable lens using wavefront sensing. We develop the optimized optical set-up with two adaptive operational states of the ETL in order to focus the light either on the retina or on the anterior segment of the eye. We test the performance of the set-up by utilizing whole eye phantom as the object. Finally, we perform human eye in vivo imaging using the SS-OCT instrument with versatile imaging functionality that accounts for the optics of the eye and enables dynamic control of the optical beam focus.

  17. The Chandra Strong Lens Sample: Revealing Baryonic Physics In Strong Lensing Selected Clusters

    NASA Astrophysics Data System (ADS)

    Bayliss, Matthew

    2017-08-01

    We propose for Chandra imaging of the hot intra-cluster gas in a unique new sample of 29 galaxy clusters selected purely on their strong gravitational lensing signatures. This will be the first program targeting a purely strong lensing selected cluster sample, enabling new comparisons between the ICM properties and scaling relations of strong lensing and mass/ICM selected cluster samples. Chandra imaging, combined with high precision strong lens models, ensures powerful constraints on the distribution and state of matter in the cluster cores. This represents a novel angle from which we can address the role played by baryonic physics |*| the infamous |*|gastrophysics|*| in shaping the cores of massive clusters, and opens up an exciting new galaxy cluster discovery space with Chandra.

  18. The Chandra Strong Lens Sample: Revealing Baryonic Physics In Strong Lensing Selected Clusters

    NASA Astrophysics Data System (ADS)

    Bayliss, Matthew

    2017-09-01

    We propose for Chandra imaging of the hot intra-cluster gas in a unique new sample of 29 galaxy clusters selected purely on their strong gravitational lensing signatures. This will be the first program targeting a purely strong lensing selected cluster sample, enabling new comparisons between the ICM properties and scaling relations of strong lensing and mass/ICM selected cluster samples. Chandra imaging, combined with high precision strong lens models, ensures powerful constraints on the distribution and state of matter in the cluster cores. This represents a novel angle from which we can address the role played by baryonic physics -- the infamous ``gastrophysics''-- in shaping the cores of massive clusters, and opens up an exciting new galaxy cluster discovery space with Chandra.

  19. Binocular function to increase visual outcome in patients implanted with a diffractive trifocal intraocular lens.

    PubMed

    Kretz, Florian T A; Müller, Matthias; Gerl, Matthias; Gerl, Ralf H; Auffarth, Gerd U

    2015-08-21

    To evaluate binocular visual outcome for near, intermediate and distance compared to monocular visual outcome at the same distances in patients implanted with a diffractive trifocal intraocular lens (IOL). The study comprised of 100 eyes of 50 patients that underwent bilateral refractive lens exchange or cataract surgery with implantation of a multifocal diffractive IOL (AT LISA tri 839MP, Carl Zeiss Meditech, Germany). A complete ophthalmological examination was performed preoperatively and 3 month postoperatively. The main outcome measures were monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), and uncorrected near visual acuities (UNVA), keratometry, and manifest refraction. The mean age was 59.28 years ± 9.6 [SD] (range 44-79 years), repectively. There was significant improvement in UDVA, UIVA, UNVA and CDVA. Comparing the monocular results to the binocular results there was a statistical significant better binocular outcome in all distances (UDVA p = 0.036; UIVA p < 0.0001; UNVA p = 0.001). The postoperative manifest refraction was in 86 % of patients within ± 0.50 [D]. The trifocal IOL improved near, intermediate, and distance vision compared to preoperatively. In addition a statistical significant increase for binocular visual function in all distances could be found. German Clinical Trials Register (DRKS) DRKS00007837.

  20. A PDMS-based cylindrical hybrid lens for enhanced fluorescence detection in microfluidic systems.

    PubMed

    Lin, Bor-Shyh; Yang, Yu-Ching; Ho, Chong-Yi; Yang, Han-Yu; Wang, Hsiang-Yu

    2014-02-13

    Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.

  1. Evaluation of the Dark-Medium Objective Lens in Counting Asbestos Fibers by Phase-Contrast Microscopy

    PubMed Central

    Lee, Eun Gyung; Nelson, John H.; Kashon, Michael L.; Harper, Martin

    2015-01-01

    A Japanese round-robin study revealed that analysts who used a dark-medium (DM) objective lens reported higher fiber counts from American Industrial Hygiene Association (AIHA) Proficiency Analytical Testing (PAT) chrysotile samples than those using a standard objective lens, but the cause of this difference was not investigated at that time. The purpose of this study is to determine any major source of this difference by performing two sets of round-robin studies. For the first round-robin study, 15 AIHA PAT samples (five each of chrysotile and amosite generated by water-suspended method, and five chrysotile generated by aerosolization method) were prepared with relocatable cover slips and examined by nine laboratories. A second round-robin study was then performed with six chrysotile field sample slides by six out of nine laboratories who participated in the first round-robin study. In addition, two phase-shift test slides to check analysts’ visibility and an eight-form diatom test plate to compare resolution between the two objectives were examined. For the AIHA PAT chrysotile reference slides, use of the DM objective resulted in consistently higher fiber counts (1.45 times for all data) than the standard objective (P-value < 0.05), regardless of the filter generation (water-suspension or aerosol) method. For the AIHA PAT amosite reference and chrysotile field sample slides, the fiber counts between the two objectives were not significantly different. No statistically significant differences were observed in the visibility of blocks of the test slides between the two objectives. Also, the DM and standard objectives showed no pattern of differences in viewing the fine lines and/or dots of each species images on the eight-form diatom test plate. Among various potential factors that might affect the analysts’ performance of fiber counts, this study supports the greater contrast caused by the different phase plate absorptions as the main cause of high counts for the AIHA PAT chrysotile slides using the DM objective. The comparison of fiber count ratios (DM/standard) between the AIHA PAT chrysotile samples and chrysotile field samples indicates that there is a fraction of fibers in the PAT samples approaching the theoretical limit of visibility of the phase-contrast microscope with 3-degree phase-shift. These fibers become more clearly visible through the greater contrast from the phase plate absorption of the DM objective. However, as such fibers are not present in field samples, no difference in counts between the two objectives was observed in this study. The DM objective, therefore, could be allowed for routine fiber counting as it will maintain continuity with risk assessments based on earlier phase-contrast microscopy fiber counts from field samples. Published standard methods would need to be modified to allow a higher aperture specification for the objective. PMID:25737333

  2. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study.

    PubMed

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40-36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%-49.74%), 22.82% (95% CI: 21.77%-23.88%), and 4.57% (95% CI: 4.05-5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years.

  3. Morphology of contact lens-induced conjunctival epithelial flaps: a pilot study.

    PubMed

    Bergmanson, Jan P G; Tukler, Johanna; Leach, Norman E; Alabdelmoneam, Mussaed; Miller, William L

    2012-08-01

    Conjunctival epithelial flap (CEF) is a conjunctival condition most commonly seen in silicone hydrogel contact lens wearers. This study utilized impression cytology to investigate the cellular composition and health of CEFs. Nine (9) subjects were enrolled - 3 non-lens wearers, 3 contact lens wearers without CEF, and 3 contact lens wearers with CEFs wearing 8.4/13.8 lotrafilcon A lenses. Impression cytology samples were collected from the flap or similar locations, if CEF was absent, using rectangular 5 mm × 2 mm Millipore HAWP02500 membrane filters. The filters were gently pressed onto the conjunctiva, subsequently fixed in 95% alcohol, stained with hematoxylin-eosin and evaluated under an Olympus IX70 microscope. Measurements of the longest cell and nucleus dimensions were measured on 40 cells from each filter by utilizing NIH Image 1.63. CEF consisted of multilayers of epithelial and goblet cells and were devoid of inflammatory cells, basement membrane material and stromal tissue. The cytoplasmic and nuclear dimensions were similar within the groups and the cytoplasm-to-nucleus ratio was not different between the flap group and the non-lens wearing group. The CEF appeared to be formed by healthy epithelial and goblet cells that have been dislocated from their normal location along the conjunctival surface by the lens edge. No inflammatory cells were present in this contact lens induced condition, which is reported to be associated most commonly with the silicone hydrogel material. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Analysis of nutrition judgments using the Nutrition Facts Panel.

    PubMed

    González-Vallejo, Claudia; Lavins, Bethany D; Carter, Kristina A

    2016-10-01

    Consumers' judgments and choices of the nutritional value of food products (cereals and snacks) were studied as a function of using information in the Nutrition Facts Panel (NFP, National Labeling and Education Act, 1990). Brunswik's lens model (Brunswik, 1955; Cooksey, 1996; Hammond, 1955; Stewart, 1988) served as the theoretical and analytical tool for examining the judgment process. Lens model analysis was further enriched with the criticality of predictors' technique developed by Azen, Budescu, & Reiser (2001). Judgment accuracy was defined as correspondence between consumers' judgments and the nutritional quality index, NuVal(®), obtained from an expert system. The study also examined several individual level variables (e.g., age, gender, BMI, educational level, health status, health beliefs, etc.) as predictors of lens model indices that measure judgment consistency, judgment accuracy, and knowledge of the environment. Results showed varying levels of consistency and accuracy depending on the food product, but generally the median values of the lens model statistics were moderate. Judgment consistency was higher for more educated individuals; judgment accuracy was predicted from a combination of person level characteristics, and individuals who reported having regular meals had models that were in greater agreement with the expert's model. Lens model methodology is a useful tool for understanding how individuals perceive the nutrition in foods based on the NFP label. Lens model judgment indices were generally low, highlighting that the benefits of the complex NFP label may be more modest than what has been previously assumed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Water-chemistry data collected in and near Kaloko-Honokohau National Historical Park, Hawaii, 2012–2014

    USGS Publications Warehouse

    Tillman, Fred D.; Oki, Delwyn S.; Johnson, Adam G.

    2014-01-01

    Kaloko-Honokōhau National Historical Park (KAHO) on western Hawaiʻi was established in 1978 to preserve, interpret, and perpetuate traditional Native Hawaiian culture and activities, including the preservation of a variety of culturally and ecologically significant water resources that are vital to this mission. KAHO water bodies provide habitat for 1 threatened, 11 endangered, and 3 candidate threatened or endangered species. These habitats are sustained by, and in the case of ʻAimakapā Fishpond and the anchialine pools, entirely dependent on, groundwater from the Keauhou aquifer system. Development of inland impounded groundwater in the Keauhou aquifer system may affect the coastal freshwater-lens system on which KAHO depends, if the inland impounded-groundwater and coastal freshwater-lens systems are hydrologically connected. This report documents water-chemistry results from a U.S. Geological Survey study that collected and analyzed water samples from 2012 to 2014 from 25 sites in and near KAHO to investigate potential geochemical indicators in water that might indicate the presence or absence of a hydrologic connection between the inland impounded-groundwater and coastal freshwater-lens systems in the area. Samples were collected under high-tide and low-tide conditions for KAHO sites, and in dry-season and wet-season conditions for all sites. Samples were collected from two ocean sites, two fishponds, three anchialine pools, and three monitoring wells within KAHO. Two additional nearshore wells were sampled on property adjacent to and north of KAHO. Additional samples from the freshwater-lens system were collected from six inland wells located upslope from KAHO, including three production wells. Seven production wells in the inland impounded-groundwater system also were sampled. Water samples were analyzed for major ions, selected trace elements, rare-earth elements, strontium-isotope ratio, and stable isotopes of water. Precipitation samples from five sites were collected roughly along a transect upslope from KAHO. All precipitation samples were analyzed for stable isotopes of water and some precipitation samples were analyzed for rare-earth and selected trace elements.

  6. Adaptable Design Improvements for Electromagnetic Shock Wave Lithotripters and Techniques for Controlling Cavitation

    NASA Astrophysics Data System (ADS)

    Smith, Nathan Birchard

    In this dissertation work, the aim was to garner better mechanistic understanding of how shock wave lithotripsy (SWL) breaks stones in order to guide design improvements to modern electromagnetic (EM) shock wave lithotripters. To accomplish this goal, experimental studies were carefully designed to isolate mechanisms of fragmentation, and models for wave propagation, fragmentation, and stone motion were developed. In the initial study, a representative EM lithotripter was characterized and tested for in vitro stone comminution efficiency at a variety of field positions and doses using phantom kidney stones of variable physical properties, and in different fluid mediums to isolate the contribution of cavitation. Through parametric analysis of the acoustic field measurements alongside comminution results, a logarithmic correlation was determined between average peak pressure incident on the stone surface and comminution efficiency. It was also noted that for a given stone type, the correlations converged to an average peak pressure threshold for fragmentation, independent of fluid medium in use. The correlation of average peak pressure to efficacy supports the rationale for the acoustic lens modifications, which were pursued to simultaneously enhance beam width and optimize the pulse profile of the lithotripter shock wave (LSW) via in situ pulse superposition for improved stone fragmentation by stress waves and cavitation, respectively. In parallel, a numerical model for wave propagation was used to investigate the variations of critical parameters with changes in lens geometry. A consensus was reached on a new lens design based on high-speed imaging and stone comminution experiments against the original lens at a fixed acoustic energy setting. The results have demonstrated that the new lens has improved efficacy away from the focus, where stones may move due to respiration, fragmentation, acoustic radiation forces, or voluntary patient movements. Using the traditional theory of brittle fragmentation and newfound understanding of average peak pressure correlation to stone comminution, the entire set of stone comminution data for lens comparison was heuristically modeled using a Weibull-style distribution function. This model linked both the average peak pressure and shock wave dose to efficacy, including their respective threshold parameters, and demonstrated correlation of coefficients to cavitation activity. Subsequently, this model was used in prediction of stone comminution efficiency from mimicked respiratory motions in vitro, which compared favorably to actual simulated motion studies using both the new and original lenses. Under a variety of mimicked respiratory motions, the new lens produced statistically higher stone comminution efficiency than the original lens. These results were confirmed in vivo in a swine model, where the new lens produced statistically higher stone comminution after 1,000 and 2,000 shocks. Finally, a mechanistic investigation into the effects of cavitation with the original lens was conducted using an integrated, self-focusing annular ring transducer specially designed for tandem pulse lithotripsy. It was found that cavitation and stone comminution efficiency are progressively enhanced by tandem pulsing as source energies of both the primary LSW and trailing pressure pulse increase, which suggests that cavitation and stress waves act synergistically to enhance the efficacy in kidney stone fragmentation.

  7. High resolution computational on-chip imaging of biological samples using sparsity constraint (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Rivenson, Yair; Wu, Chris; Wang, Hongda; Zhang, Yibo; Ozcan, Aydogan

    2017-03-01

    Microscopic imaging of biological samples such as pathology slides is one of the standard diagnostic methods for screening various diseases, including cancer. These biological samples are usually imaged using traditional optical microscopy tools; however, the high cost, bulkiness and limited imaging throughput of traditional microscopes partially restrict their deployment in resource-limited settings. In order to mitigate this, we previously demonstrated a cost-effective and compact lens-less on-chip microscopy platform with a wide field-of-view of >20-30 mm^2. The lens-less microscopy platform has shown its effectiveness for imaging of highly connected biological samples, such as pathology slides of various tissue samples and smears, among others. This computational holographic microscope requires a set of super-resolved holograms acquired at multiple sample-to-sensor distances, which are used as input to an iterative phase recovery algorithm and holographic reconstruction process, yielding high-resolution images of the samples in phase and amplitude channels. Here we demonstrate that in order to reconstruct clinically relevant images with high resolution and image contrast, we require less than 50% of the previously reported nominal number of holograms acquired at different sample-to-sensor distances. This is achieved by incorporating a loose sparsity constraint as part of the iterative holographic object reconstruction. We demonstrate the success of this sparsity-based computational lens-less microscopy platform by imaging pathology slides of breast cancer tissue and Papanicolaou (Pap) smears.

  8. Photometric redshift requirements for lens galaxies in galaxy-galaxy lensing analyses

    NASA Astrophysics Data System (ADS)

    Nakajima, R.; Mandelbaum, R.; Seljak, U.; Cohn, J. D.; Reyes, R.; Cool, R.

    2012-03-01

    Weak gravitational lensing is a valuable probe of galaxy formation and cosmology. Here we quantify the effects of using photometric redshifts (photo-z) in galaxy-galaxy lensing, for both sources and lenses, both for the immediate goal of using galaxies with photo-z as lenses in the Sloan Digital Sky Survey (SDSS) and as a demonstration of methodology for large, upcoming weak lensing surveys that will by necessity be dominated by lens samples with photo-z. We calculate the bias in the lensing mass calibration as well as consequences for absolute magnitude (i.e. k-corrections) and stellar mass estimates for a large sample of SDSS Data Release 8 (DR8) galaxies. The redshifts are obtained with the template-based photo-z code ZEBRA on the SDSS DR8 ugriz photometry. We assemble and characterize the calibration samples (˜9000 spectroscopic redshifts from four surveys) to obtain photometric redshift errors and lensing biases corresponding to our full SDSS DR8 lens and source catalogues. Our tests of the calibration sample also highlight the impact of observing conditions in the imaging survey when the spectroscopic calibration covers a small fraction of its footprint; atypical imaging conditions in calibration fields can lead to incorrect conclusions regarding the photo-z of the full survey. For the SDSS DR8 catalogue, we find σΔz/(1+z)= 0.096 and 0.113 for the lens and source catalogues, with flux limits of r= 21 and 21.8, respectively. The photo-z bias and scatter is a function of photo-z and template types, which we exploit to apply photo-z quality cuts. By using photo-z rather than spectroscopy for lenses, dim blue galaxies and L* galaxies up to z˜ 0.4 can be used as lenses, thus expanding into unexplored areas of parameter space. We also explore the systematic uncertainty in the lensing signal calibration when using source photo-z, and both lens and source photo-z; given the size of existing training samples, we can constrain the lensing signal calibration (and therefore the normalization of the surface mass density) to within 2 and 4 per cent, respectively.

  9. Microwave Nondestructive Evaluation of Dielectric Materials with a Metamaterial Lens

    NASA Technical Reports Server (NTRS)

    Shreiber, Daniel; Gupta, Mool; Cravey, Robin L.

    2008-01-01

    A novel microwave Nondestructive Evaluation (NDE) sensor was developed in an attempt to increase the sensitivity of the microwave NDE method for detection of defects small relative to a wavelength. The sensor was designed on the basis of a negative index material (NIM) lens. Characterization of the lens was performed to determine its resonant frequency, index of refraction, focus spot size, and optimal focusing length (for proper sample location). A sub-wavelength spot size (3 dB) of 0.48 lambda was obtained. The proof of concept for the sensor was achieved when a fiberglass sample with a 3 mm diameter through hole (perpendicular to the propagation direction of the wave) was tested. The hole was successfully detected with an 8.2 cm wavelength electromagnetic wave. This method is able to detect a defect that is 0.037 lambda. This method has certain advantages over other far field and near field microwave NDE methods currently in use.

  10. Early lens ablation causes dramatic long-term effects on the shape of bones in the craniofacial skeleton of Astyanax mexicanus.

    PubMed

    Dufton, Megan; Hall, Brian K; Franz-Odendaal, Tamara A

    2012-01-01

    The Mexican tetra, Astyanax mexicanus, exists as two morphs of a single species, a sighted surface morph and a blind cavefish. In addition to eye regression, cavefish have an increased number of taste buds, maxillary teeth and have an altered craniofacial skeleton compared to the sighted morph. We investigated the effect the lens has on the development of the surrounding skeleton, by ablating the lens at different time points during ontogeny. This unique long-term study sheds light on how early embryonic manipulations on the eye can affect the shape of the adult skull more than a year later, and the developmental window during which time these effects occur. The effects of lens ablation were analyzed by whole-mount bone staining, immunohistochemisty and landmark based morphometric analyzes. Our results indicate that lens ablation has the greatest impact on the skeleton when it is ablated at one day post fertilisation (dpf) compared to at four dpf. Morphometric analyzes indicate that there is a statistically significant difference in the shape of the supraorbital bone and suborbital bones four through six. These bones expand into the eye orbit exhibiting plasticity in their shape. Interestingly, the number of caudal teeth on the lower jaw is also affected by lens ablation. In contrast, the shape of the calvariae, the length of the mandible, and the number of mandibular taste buds are unaltered by lens removal. We demonstrate the plasticity of some craniofacial elements and the stability of others in the skull. Furthermore, this study highlights interactions present between sensory systems during early development and sheds light on the cavefish phenotype.

  11. Enhancing micrographs obtained with a scanning acoustic microscope using false-color encoding

    NASA Astrophysics Data System (ADS)

    Hammer, R.; Hollis, R. L.

    1982-04-01

    The periodic signal variations observed in reflection acoustic microscopy when lens-to-sample spacing is changed lead to reversals in image contrast. This contrast mechanism can be described by a V(Z) function, where V is the transducer voltage and Z the lens-to-sample spacing. In this work we show how by obtaining V(Z) curves from each plane of a complex sample, judicious choices of focal positions can be made to optimize signals from planes of interest, which allows color encoding of the image from each plane in an overlay image. We present false-color micrographs obtained in this way, along with A scans and V(Z) curves to demonstrate the technique.

  12. Recommended coordinate systems for thin spherocylindrical lenses.

    PubMed

    Deal, F C; Toop, J

    1993-05-01

    Because the set of thin spherocylindrical lenses forms a vector space, any such lens can be expressed in terms of its cartesian coordinates with respect to whatever set of basis lenses we may choose. Two types of cartesian coordinate systems have become prominent, those having coordinates associated with the lens power matrix and those having coordinates associated with the Humphrey Vision Analyzer. This paper emphasizes the value of a particular cartesian coordinate system of the latter type, and the cylindrical coordinate system related to it, by showing how it can simplify the trigonometry of adding lenses and how it preserves symmetry in depicting the sets of all spherical lenses, all Jackson crossed-cylinders, and all cylindrical lenses. It also discusses appropriate coordinates for keeping statistics on lenses and shows that an easy extension of the lens vector space to include general optical systems is not possible.

  13. STRONG LENS TIME DELAY CHALLENGE. II. RESULTS OF TDC1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Kai; Treu, Tommaso; Marshall, Phil

    2015-02-10

    We present the results of the first strong lens time delay challenge. The motivation, experimental design, and entry level challenge are described in a companion paper. This paper presents the main challenge, TDC1, which consisted of analyzing thousands of simulated light curves blindly. The observational properties of the light curves cover the range in quality obtained for current targeted efforts (e.g., COSMOGRAIL) and expected from future synoptic surveys (e.g., LSST), and include simulated systematic errors. Seven teams participated in TDC1, submitting results from 78 different method variants. After describing each method, we compute and analyze basic statistics measuring accuracy (ormore » bias) A, goodness of fit χ{sup 2}, precision P, and success rate f. For some methods we identify outliers as an important issue. Other methods show that outliers can be controlled via visual inspection or conservative quality control. Several methods are competitive, i.e., give |A| < 0.03, P < 0.03, and χ{sup 2} < 1.5, with some of the methods already reaching sub-percent accuracy. The fraction of light curves yielding a time delay measurement is typically in the range f = 20%-40%. It depends strongly on the quality of the data: COSMOGRAIL-quality cadence and light curve lengths yield significantly higher f than does sparser sampling. Taking the results of TDC1 at face value, we estimate that LSST should provide around 400 robust time-delay measurements, each with P < 0.03 and |A| < 0.01, comparable to current lens modeling uncertainties. In terms of observing strategies, we find that A and f depend mostly on season length, while P depends mostly on cadence and campaign duration.« less

  14. Rapid Assessment of the Ce-Co-Fe-Cu System for Permanent Magnetic Applications

    DOE PAGES

    Meng, F.; Chaudhary, R. P.; Gandha, K.; ...

    2018-04-23

    Here, this work focuses on the rapid synthesis and characterization of quaternary Ce(CoFeCu) 5 alloy libraries to assess their potential viability as permanent magnets. Arrays of bulk specimens with controlled compositions were synthesized via laser engineered net shaping (LENS) by feeding different ratios of alloy powders into a melt pool created by a laser. Based on the assessment of the magnetic properties of the LENS printed samples, arc-melted and cast ingots were prepared with varying Fe (5–20 at.%) and Co (60–45 at.%) compositions while maintaining constant Ce (16 at.%) and Cu (19 at.%) content. The evolution of the microstructure andmore » phases with varying chemical compositions and their dependence on magnetic properties are analyzed in as-cast and heat-treated samples. In both the LENS printed and cast samples, we find the best magnetic properties correspond to a predominantly single-phase Ce(CoFeCu) 5 microstructure in which high coercivity ( H c > 10 kOe) can be achieved without any microstructural refinement.« less

  15. Rapid Assessment of the Ce-Co-Fe-Cu System for Permanent Magnetic Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meng, F.; Chaudhary, R. P.; Gandha, K.

    Here, this work focuses on the rapid synthesis and characterization of quaternary Ce(CoFeCu) 5 alloy libraries to assess their potential viability as permanent magnets. Arrays of bulk specimens with controlled compositions were synthesized via laser engineered net shaping (LENS) by feeding different ratios of alloy powders into a melt pool created by a laser. Based on the assessment of the magnetic properties of the LENS printed samples, arc-melted and cast ingots were prepared with varying Fe (5–20 at.%) and Co (60–45 at.%) compositions while maintaining constant Ce (16 at.%) and Cu (19 at.%) content. The evolution of the microstructure andmore » phases with varying chemical compositions and their dependence on magnetic properties are analyzed in as-cast and heat-treated samples. In both the LENS printed and cast samples, we find the best magnetic properties correspond to a predominantly single-phase Ce(CoFeCu) 5 microstructure in which high coercivity ( H c > 10 kOe) can be achieved without any microstructural refinement.« less

  16. Aldose reductase inhibitory, anti-cataract and antioxidant potential of selected medicinal plants from the Marathwada region, India.

    PubMed

    Gacche, R N; Dhole, N A

    2011-04-01

    The water, ethanol and chloroform extracts of selected plants such as Adhatoda vasica (L.) (Acanthaceae), Caesalpinia bonduc (L.), Cassia fistula (L.) (Caesalpiniaceae) and Biophytum sensitivum (L.) (Oxalidaceae) were evaluated for rat lens aldose reductase inhibitory (RLAR) potential, anti-cataract and antioxidant activities. All the samples inhibited the aldose reductase considerably and exhibited anti-cataract activity, while C. fistula (IC(50), 0.154 mg mL(-1)) showed significant RLAR inhibitory activity as compared to the other tested samples, and was further found to be more effective in maintaining sugar-induced lens opacity in the rat lens model. The antioxidant potential of plant extracts was determined using DPPH (2,2-diphenyl-1-picryl hydrazine), hydroxyl (OH), nitric oxide (NO) and hydrogen peroxide (H(2)O(2)) scavenging activities, along with determination of reducing power, ferrous ion chelating ability and inhibition of polyphenol oxidase (PPO). The extracts of the tested plant showed significant free radical scavenging activities and inhibited the activity of enzyme PPO, a model oxidising enzyme. The plant samples were found to possess considerable amounts of vitamin C, total polyphenols and flavonoids.

  17. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): A Transversal, descriptive, and comparative study

    PubMed Central

    2010-01-01

    Background To assess the reliability of the measurements obtained with the PalmScan™, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Methods Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan™ A2000 and Eye Cubed™) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. Results 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed™ of AL and ACD were shorter than the measurements taken by the PalmScan™. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan™ measurements were shorter, but not statistically significantly (p < 0.2). Conclusions The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon. PMID:20334670

  18. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    PubMed

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  19. A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: correlation between ocular biometric parameters.

    PubMed

    Ghoreishi, Mohammad; Abdi-Shahshahani, Mehdi; Peyman, Alireza; Pourazizi, Mohsen

    2018-02-21

    The aim of this study was to determine the correlation between ocular biometric parameters and sulcus-to-sulcus (STS) diameter. This was a cross-sectional study of preoperative ocular biometry data of patients who were candidates for phakic intraocular lens (IOL) surgery. Subjects underwent ocular biometry analysis, including refraction error evaluation using an autorefractor and Orbscan topography for white-to-white (WTW) corneal diameter and measurement. Pentacam was used to perform WTW corneal diameter and measurements of minimum and maximum keratometry (K). Measurements of STS and angle-to-angle (ATA) were obtained using a 50-MHz B-mode ultrasound device. Anterior optical coherence tomography was performed for anterior chamber depth measurement. Pearson's correlation test and stepwise linear regression analysis were used to find a model to predict STS. Fifty-eight eyes of 58 patients were enrolled. Mean age ± standard deviation of sample was 28.95 ± 6.04 years. The Pearson's correlation coefficient between STS with WTW, ATA, mean K was 0.383, 0.492, and - 0.353, respectively, which was statistically significant (all P < 0.001). Using stepwise linear regression analysis, there is a statistically significant association between STS with WTW (P = 0.011) and mean K (P = 0.025). The standardized coefficient was 0.323 and - 0.284 for WTW and mean K, respectively. The stepwise linear regression analysis equation was: (STS = 9.549 + 0.518 WTW - 0.083 mean K). Based on our result, given the correlation of STS with WTW and mean K and potential of direct and essay measurement of WTW and mean K, it seems that current IOL sizing protocols could be estimating with WTW and mean K.

  20. Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers

    PubMed Central

    Richdale, Kathryn; Mitchell, Gladys Lynn; Kinoshita, Beth T.; Lam, Dawn Y.; Wagner, Heidi; Sorbara, Luigina; Chalmers, Robin L.; Collier, Sarah A.; Cope, Jennifer R.; Rao, Maya M.; Beach, Michael J.; Yoder, Jonathan S.

    2017-01-01

    Purpose: To understand soft contact lens (SCL) and gas-permeable (GP) lens wearers' behaviors and knowledge regarding exposure of lenses to water. Methods: The Contact Lens Risk Survey (CLRS) and health behavior questions were completed online by a convenience sample of 1056 SCL and 85 GP lens wearers aged 20 to 76 years. Participants were asked about exposing their lenses to water and their understanding of risks associated with these behaviors. Chi-square analyses examined relationships between patient behaviors and perceptions. Results: GP lens wearers were more likely than SCL wearers to ever rinse or store lenses in water (rinsing: 91% GP, 31% SCL, P < 0.001; storing: 33% GP, 15% SCL P < 0.001). Among SCL wearers, men were more likely to store (24% vs. 13%, P = 0.003) or rinse (41% vs. 29%, P = 0.012) their lenses in water. Showering while wearing lenses was more common in SCL wearers (86%) than GP lens wearers (67%) (P < 0.0001). Swimming while wearing lenses was reported by 62% of SCL wearers and 48% of GP lens wearers (P = 0.027). Wearers who rinsed (SCL; P < 0.0001, GP; P = 0.11) or stored lenses in water (SCL; P < 0.0001, GP P = 0.007) reported that this behavior had little or no effect on their infection risk, compared with those who did not. Both SCL (P < 0.0001) and GP lens wearers (P < 0.0001) perceived that distilled water was safer than tap water for storing or rinsing lenses. Conclusions: Despite previously published evidence of Acanthamoeba keratitis' association with water exposure, most SCL, and nearly all GP lens wearers, regularly expose their lenses to water, with many unaware of the risk. PMID:28410356

  1. Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers.

    PubMed

    Zimmerman, Aaron B; Richdale, Kathryn; Mitchell, Gladys Lynn; Kinoshita, Beth T; Lam, Dawn Y; Wagner, Heidi; Sorbara, Luigina; Chalmers, Robin L; Collier, Sarah A; Cope, Jennifer R; Rao, Maya M; Beach, Michael J; Yoder, Jonathan S

    2017-08-01

    To understand soft contact lens (SCL) and gas-permeable (GP) lens wearers' behaviors and knowledge regarding exposure of lenses to water. The Contact Lens Risk Survey (CLRS) and health behavior questions were completed online by a convenience sample of 1056 SCL and 85 GP lens wearers aged 20 to 76 years. Participants were asked about exposing their lenses to water and their understanding of risks associated with these behaviors. Chi-square analyses examined relationships between patient behaviors and perceptions. GP lens wearers were more likely than SCL wearers to ever rinse or store lenses in water (rinsing: 91% GP, 31% SCL, P < 0.001; storing: 33% GP, 15% SCL P < 0.001). Among SCL wearers, men were more likely to store (24% vs. 13%, P = 0.003) or rinse (41% vs. 29%, P = 0.012) their lenses in water. Showering while wearing lenses was more common in SCL wearers (86%) than GP lens wearers (67%) (P < 0.0001). Swimming while wearing lenses was reported by 62% of SCL wearers and 48% of GP lens wearers (P = 0.027). Wearers who rinsed (SCL; P < 0.0001, GP; P = 0.11) or stored lenses in water (SCL; P < 0.0001, GP P = 0.007) reported that this behavior had little or no effect on their infection risk, compared with those who did not. Both SCL (P < 0.0001) and GP lens wearers (P < 0.0001) perceived that distilled water was safer than tap water for storing or rinsing lenses. Despite previously published evidence of Acanthamoeba keratitis' association with water exposure, most SCL, and nearly all GP lens wearers, regularly expose their lenses to water, with many unaware of the risk.

  2. The effects of surgical factors on postoperative astigmatism in patients enrolled in the Infant Aphakia Treatment Study (IATS).

    PubMed

    Wall, Palak B; Lee, Jason A; Lynn, Michael J; Lambert, Scott R; Traboulsi, Elias I

    2014-10-01

    To evaluate the effect of surgical factors on postoperative astigmatism in infants undergoing cataract extraction with or without intraocular lens (IOL) implantation. The Infant Aphakia Treatment Study is a multicenter clinical trial in which 114 infants with unilateral congenital cataracts were randomized to undergo cataract extraction with IOL placement or contact lens aphakic correction. Surgical videos were reviewed with regard to incision type and location, whether the incision was extended, the number of sutures placed, and technique of closure. Corneal astigmatism was measured using a handheld keratometer prior to surgery and at 1 year of age. Corneal astigmatism decreased from a mean of 1.92 D at baseline to 1.62 D at age 1 year in the contact lens group but remained almost unchanged from 2.00 D to 2.09 D in the IOL group (P = 0.023). There was no statistical difference between the amount of corneal astigmatism with regard to incision type (P = 0.214) and no increase in astigmatism with extension of the incision to facilitate IOL placement (P = 0.849) at 1 year. The number of sutures and technique of closure did not influence the amount of astigmatism at 1 year. At the age of 1 year following cataract extraction in infants, contact lens correction and the lack of IOL placement are associated with a significant decrease in postoperative corneal astigmatism compared to IOL placement. No other surgical factors considered in this study had a statistically significant effect on corneal astigmatism. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  3. Tunable-Bandwidth Filter System

    NASA Technical Reports Server (NTRS)

    Bailey, John W.

    2004-01-01

    A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

  4. Tunable-Bandwidth Filter System

    NASA Technical Reports Server (NTRS)

    Aye, Tin; Yu, Kevin; Dimov, Fedor; Savant, Gajendra

    2006-01-01

    A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

  5. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study

    PubMed Central

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313

  6. Low voltage electrowetting lenticular lens by using multilayer dielectric structure

    NASA Astrophysics Data System (ADS)

    Lee, Junsik; Kim, Junoh; Kim, Cheoljoong; Shin, Dooseub; Koo, Gyohyun; Sim, Jee Hoon; Won, Yong Hyub

    2017-02-01

    Lenticular type multi-view display is one of the most popular ways for implementing three dimensional display. This method has a simple structure and exhibits a high luminance. However, fabricating the lenticular lens is difficult because it requires optically complex calculations. 2D-3D conversion is also impossible due to the fixed shape of the lenticular lens. Electrowetting based liquid lenticular lens has a simple fabrication process compared to the solid lenticular lens and the focal length of the liquid lenticular lens can be changed by applying the voltage. 3D and 2D images can be observed with a convex and a flat lens state respectively. Despite these advantages, the electrowetting based liquid lenticular lens demands high driving voltage and low breakdown voltage with a single dielectric layer structure. A certain degree of thickness of the dielectric layer is essential for a uniform operation and a low degradation over time. This paper presents multilayer dielectric structure which results in low driving voltage and the enhanced dielectric breakdown. Aluminum oxide (Al2O3), silicon oxide (SiO2) and parylene C were selected as the multilayer insulators. The total thickness of the dielectric layer of all samples was the same. This method using the multilayer dielectric structure can achieve the lower operating voltage than when using the single dielectric layer. We compared the liquid lenticular lens with three kinds of the multilayer dielectric structure to one with the parylene C single dielectric layer in regard to operational characteristics such as the driving voltage and the dielectric breakdown.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, J.; Nlebedim, I. C.; Besser, M. F.

    A bulk combinatorial approach for synthesizing alloy libraries using laser engineered net shaping (LENS; i.e., 3D printing) was utilized to rapidly assess material systems for magnetic applications. The LENS system feeds powders in different ratios into a melt pool created by a laser to synthesize samples with bulk (millimeters) dimensions. By analyzing these libraries with autosampler differential scanning calorimeter/thermal gravimetric analysis and vibrating sample magnetometry, we are able to rapidly characterize the thermodynamic and magnetic properties of the libraries. Furthermore, the Fe-Co binary alloy was used as a model system and the results were compared with data in the literature.

  8. Correcting the effect of refraction and dispersion of light in FT-IR spectroscopic imaging in transmission through thick infrared windows.

    PubMed

    Chan, K L Andrew; Kazarian, Sergei G

    2013-01-15

    Transmission mode is one of the most common sampling methods for FT-IR spectroscopic imaging because the spectra obtained generally have a reasonable signal-to-noise ratio. However, dispersion and refraction of infrared light occurs when samples are sandwiched between infrared windows or placed underneath a layer of liquid. Dispersion and refraction cause infrared light to focus with different focal lengths depending on the wavelength (wavenumber) of the light. As a result, images obtained are in focus only at a particular wavenumber while they are defocused at other wavenumber values. In this work, a solution to correct this spread of focus by means of adding a lens on top of the infrared transparent window, such that a pseudo hemisphere is formed, has been investigated. Through this lens (or pseudo hemisphere), refraction of light is removed and the light across the spectral range has the same focal depth. Furthermore, the lens acts as a solid immersion objective and an increase of both magnification and spatial resolution (by 1.4 times) is demonstrated. The spatial resolution was investigated using an USAF resolution target, showing that the Rayleigh criterion can be achieved, as well as a sample with a sharp polymer interface to indicate the spatial resolution that can be expected in real samples. The reported approach was used to obtain chemical images of cross sections of cancer tissue and hair samples sandwiched between infrared windows showing the versatility and applicability of the method. In addition to the improved spatial resolution, the results reported herein also demonstrate that the lens can reduce the effect of scattering near the edges of tissue samples. The advantages of the presented approach, obtaining FT-IR spectroscopic images in transmission mode with the same focus across all wavenumber values and simultaneous improvement in spatial resolution, will have wide implications ranging from studies of live cells to sorption of drugs into tissues.

  9. Optimal power distribution for minimizing pupil walk in a 7.5X afocal zoom lens

    NASA Astrophysics Data System (ADS)

    Song, Wanyue; Zhao, Yang; Berman, Rebecca; Bodell, S. Yvonne; Fennig, Eryn; Ni, Yunhui; Papa, Jonathan C.; Yang, Tianyi; Yee, Anthony J.; Moore, Duncan T.; Bentley, Julie L.

    2017-11-01

    An extensive design study was conducted to find the best optimal power distribution and stop location for a 7.5x afocal zoom lens that controls the pupil walk and pupil location through zoom. This afocal zoom lens is one of the three components in a VIS-SWIR high-resolution microscope for inspection of photonic chips. The microscope consists of an afocal zoom, a nine-element objective and a tube lens and has diffraction limited performance with zero vignetting. In this case, the required change in object (sample) size and resolution is achieved by the magnification change of the afocal component. This creates strict requirements for both the entrance and exit pupil locations of the afocal zoom to couple the two sides successfully. The first phase of the design study looked at conventional four group zoom lenses with positive groups in the front and back and the stop at a fixed location outside the lens but resulted in significant pupil walk. The second phase of the design study focused on several promising unconventional four-group power distribution designs with moving stops that minimized pupil walk and had an acceptable pupil location (as determined by the objective and tube lens).

  10. Non-destructive analysis of the conformational changes in human lens lipid and protein structures of the immature cataracts associated with glaucoma

    NASA Astrophysics Data System (ADS)

    Lin, Shan-Yang; Li, Mei-Jane; Liang, Run-Chu; Lee, Shui-Mei

    1998-09-01

    Previous study has supposed a possible mechanism of exacerbating cataract formation in cataractous human lens capsules induced by hypertension or glaucoma. To clarify the glaucoma-induced cataract formation of the eyes lens, changes in the human lens lipid and protein structures of immature cataractous patients with or without glaucoma were investigated. Two normal lenses, ten immature cataractous lenses without any complication and four immature cataractous lenses with glaucoma were used after surgical operation. Each de-capsulated human lens sample was sliced with a number 15 surgical blade. The intact nuclear lens regions were used for non-destructive analysis. The lens lipid and protein structures, as well as compositions of these lens samples, were determined using a Fourier transform infrared (FTIR) microspectroscopy with second-derivative, de-convolution and curve-fitting methods. The results indicate that the IR spectrum of glaucomatous lenses appeared as a shoulder only at 2853 cm -1, thus the composition of the symmetric CH 2 stretching band at 2853 (2852) cm -1 decreased more significantly in glaucomatous lens to only one half of that in normal and immature cataractous lenses. The composition of the asymmetric CH 3 stretching band at 2965 cm -1 for normal lens decreases markedly from 32 to 20% for immature cataractous lenses with or without glaucoma. The compositional ratio of component at 2965 cm -1 to component at 2928 (2930) cm -1 for normal lenses was about 0.702, and that ratio for cataractous lenses without glaucoma was 0.382 but for glaucomatous lenses was 0.377. The maximum peak position of amide I band for IR spectra of the normal lens, immature cataractous lenses without complications or glaucomatous lenses appeared respectively at 1632, 1630 or 1622 cm -1, assigned to β sheet structure. A marked difference in peak intensity of amide I band for the normal lenses and immature cataractous human lenses with or without glaucoma was observed. The peak intensity ratio of amide I /amide II (1632/1545 cm -1) for normal lenses was in the range of 2.20-2.33, whereas in the spectra of immature cataractous lenses without glaucoma this ratio (1630/1545 cm -1) was 1.28-1.41 but was 1.04-1.13 for glaucomatous lens in the intensity ratio of 1622/1545 cm -1. The intensity of the glycogen bands in the wavenumber region 1135-1076 and 1069-1032 cm -1 was found to increase for the immature cataractous lenses with or without glaucoma, as compared with the normal ones. The peaks ranging from 1633 to 1610 cm -1 assigned to β-sheet structure also exhibited a pronounced compositional difference, particularly in glaucomatous lenses. The human lens lipid and protein secondary structures were more affected by glaucoma. Higher protein side chains and reduced lipid content contributed predominantly to the CH stretching vibrations of normal lens structure, whereas high lipid content and less protein side chains dominated the CH stretching vibrations of cataractous lenses with or without glaucoma. Decrease α-helix and random coil structures but enhanced β-sheet structure in the immature cataractous human lens induced by glaucoma might result from the formation of intermolecular hydrogen-bonding insoluble protein aggregates that modify the secondary structure of protein in lenses.

  11. Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes.

    PubMed

    Detorakis, Efstathios T; Drakonaki, Eleni E; Ginis, Harilaos; Karyotakis, Nikolaos; Pallikaris, Ioannis G

    2014-01-01

    A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.

  12. Galaxy–galaxy lensing estimators and their covariance properties

    DOE PAGES

    Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uros; ...

    2017-07-21

    Here, we study the covariance properties of real space correlation function estimators – primarily galaxy–shear correlations, or galaxy–galaxy lensing – using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens densitymore » field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.« less

  13. Development of fibrin-free intraocular lens with photochemical surface modification

    NASA Astrophysics Data System (ADS)

    Sato, Yuji; Tanizawa, Katsuya; Anai, Hiroyuki; Sato, Nobuhiro; Sato, Yuki; Ajiki, Tooru; Parel, Jean-Marie; Murahara, Masataka

    2004-07-01

    Having substituted the hydrophilic and hydrophobic groups alternately on the soft acrylic resin intraocular lens (IOL) surface by using an ArF excimer laser and a Xe2 excimer lamp, we have developed the IOL that is free from fibrin. Acrylic resin or PMMA lens has been used as an intraocular lens for 50 years. However, protein and fat are stuck onto the IOL surface after a long implantation, which opacifies the surface (after-cataract). Thus, we designed the micro domain structures of hydrophilic and hydrophobic groups on the IOL surface for fibrin-free. Firstly, the IOL was irradiated with the Xe2 excimer lamp in the presence of perfluoropolyether in order to make it hydrophobic. By this photochemical reaction, the CF3 functional groups were substituted on the IOL surface. Secondly, the ArF laser was projected on the IOL through the mask pattern in reduced size in the presence of water in order to be hydrophilic. With the photochemical reaction, the OH groups were substituted at the part exposed. The fibrin adsorption test of the modified IOL surface was carried out with FT-IR; which revealed that the fibrin-sticking rate of the treated sample has decreased by 23% compared with that of the non-treated sample. As a result, the fibrin-free IOL has been made by modifying the surface of the IOL to have the micro domain structures of the hydrophilic and hydrophobic groups that are arrayed alternately. In conclusion, the ideal intraocular lens has been demonstrated.

  14. Galaxy–galaxy lensing estimators and their covariance properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uros

    Here, we study the covariance properties of real space correlation function estimators – primarily galaxy–shear correlations, or galaxy–galaxy lensing – using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens densitymore » field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.« less

  15. Galaxy-galaxy lensing estimators and their covariance properties

    NASA Astrophysics Data System (ADS)

    Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uroš; Slosar, Anže; Vazquez Gonzalez, Jose

    2017-11-01

    We study the covariance properties of real space correlation function estimators - primarily galaxy-shear correlations, or galaxy-galaxy lensing - using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens density field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.

  16. Biochemical analyses of lipids deposited on silicone hydrogel lenses

    PubMed Central

    Hatou, Shin; Fukui, Masaki; Yatsui, Keiichi; Mochizuki, Hiroshi; Akune, Yoko; Yamada, Masakazu

    2010-01-01

    Purpose This study was performed to determine the levels of lipids deposited on in vivo worn silicone hydrogel lenses. Methods Three silicone hydrogel materials, galyfilcon A, senofilcon A, and asmofilcon A, were worn for 2 weeks by 35 normal subjects. Total lipid deposition was determined by the sulfo-phospho-vanillin reaction. Cholesterol was estimated by a colorimetric probe through enzymatic oxidation. Phospholipid level was estimated by determining phosphorus with ammonium molybdate through enzymatic digestion. Results The total lipid content recovered from galyfilcon A, senofilcon A, and asmofilcon A was 32.9 ± 33.8, 42.1 ± 14.0, and 36.6 ± 31.9 μg/lens, respectively. The cholesterol content recovered from galyfilcon A, senofilcon A, and asmofilcon A was 26.2 ± 26.9, 28.6 ± 19.4, and 31.1 ± 21.1 μg/lens, respectively. There were no statistically significant differences in total lipids and cholesterol among the contact lens types. However, the quantity of phospholipid recovered from the asmofilcon A (7.0 ± 5.5 μg/lens) lenses was significantly higher than from galyfilcon A (1.1 ± 0.8 μg/lens) and senofilcon A (2.4 ± 0.8 mg/lens) lenses (p < 0.05, Mann-Whitney test). Conclusions The quantity of total lipid and cholesterol deposited on the 3 silicone hydrogel lenses tested did not differ. However, there were significant differences in the amounts of phospholipid deposited among the 3 silicone hydrogel lenses, of which clinical significance should be explored in the future study.

  17. The role of macromolecular crowding in the evolution of lens crystallins with high molecular refractive index.

    PubMed

    Zhao, Huaying; Magone, M Teresa; Schuck, Peter

    2011-08-01

    Crystallins are present in the lens at extremely high concentrations in order to provide transparency and generate a high refractive power of the lens. The crystallin families prevalent in the highest density lens tissues are γ-crystallins in vertebrates and S-crystallins in cephalopods. As shown elsewhere, in parallel evolution, both have evolved molecular refractive index increments 5-10% above those of most proteins. Although this is a small increase, it is statistically very significant and can be achieved only by very unusual amino acid compositions. In contrast, such a molecular adaptation to aid in the refractive function of the lens did not occur in crystallins that are preferentially located in lower density lens tissues, such as vertebrate α-crystallin and taxon-specific crystallins. In the current work, we apply a model of non-interacting hard spheres to examine the thermodynamic contributions of volume exclusion at lenticular protein concentrations. We show that the small concentration decrease afforded by the higher molecular refractive index increment of crystallins can amplify nonlinearly to produce order of magnitude differences in chemical activities, and lead to reduced osmotic pressure and the reduced propensity for protein aggregation. Quantitatively, this amplification sets in only at protein concentrations as high as those found in hard lenses or the nucleus of soft lenses, in good correspondence to the observed crystallin properties in different tissues and different species. This suggests that volume exclusion effects provide the evolutionary driving force for the unusual refractive properties and the unusual amino acid compositions of γ-crystallins and S-crystallins.

  18. The role of macromolecular crowding in the evolution of lens crystallins with high molecular refractive index

    PubMed Central

    Zhao, Huaying; Magone, M. Teresa; Schuck, Peter

    2011-01-01

    Crystallins are present in the lens at extremely high concentrations in order to provide transparency and generate a high refractive power of the lens. The crystallin families prevalent in the highest density lens tissues are γ crystallins in vertebrates and S crystallins in cephalopods. In parallel evolution, both have evolved molecular refractive index increments 5 – 10 % above those of most proteins. Although this is a small increase, it is statistically very significant and can be achieved only by very unusual amino acid compositions. In contrast, such a molecular adaptation to aid in the refractive function of the lens did not occur in crystallins that are preferentially located in lower density lens tissues, such as vertebrate α crystallin and taxon specific crystallins. In the current work, we apply a model of non-interacting hard spheres to examine the thermodynamic contributions of volume exclusion at lenticular protein concentrations. We show that the small concentration decrease afforded by the higher molecular refractive index increment of crystallins can amplify nonlinearly to produce order of magnitude differences in chemical activities, and lead to reduced osmotic pressure and the reduced propensity for protein aggregation. Quantitatively, this amplification sets in only at protein concentrations as high as those found in hard lenses or the nucleus of soft lenses, in good correspondence to the observed crystalline properties in different tissues and different species. This suggests that volume exclusion effects provide the evolutionary driving force for the unusual refractive properties and the unusual amino acid compositions of γ crystallins and S crystallins. PMID:21566271

  19. Time resolved thermal lens in edible oils

    NASA Astrophysics Data System (ADS)

    Albuquerque, T. A. S.; Pedreira, P. R. B.; Medina, A. N.; Pereira, J. R. D.; Bento, A. C.; Baesso, M. L.

    2003-01-01

    In this work time resolved thermal lens spectrometry is applied to investigate the optical properties of the following edible oils: soya, sunflower, canola, and corn oils. The experiments were performed at room temperature using the mode mismatched thermal lens configuration. The results showed that when the time resolved procedure is adopted the technique can be applied to investigate the photosensitivity of edible oils. Soya oil presented a stronger photochemical reaction as compared to the other investigated samples. This observation may be relevant for future studies evaluating edible oils storage conditions and also may contribute to a better understanding of the physical and chemical properties of this important foodstuff.

  20. Indirect tissue electrophoresis: a new method for analyzing solid tissue protein.

    PubMed

    Smith, A C

    1988-01-01

    1. The eye lens core (nucleus) has been a valuable source of molecular biologic information. 2. In these studies, lens nuclei are usually homogenized so that any protein information related to anatomical subdivisions, or layers, of the nucleus is lost. 3. The present report is of a new method, indirect tissue electrophoresis (ITE), which, when applied to fish lens nuclei, permitted (a) automatic correlation of protein information with anatomic layer, (b) production of large, clear electrophoretic patterns even from small tissue samples and (c) detection of more proteins than in liquid extracts of homogenized tissues. 4. ITE seems potentially applicable to a variety of solid tissues.

  1. Uniform Laser Excitation And Detection In Capillary Array Electrophoresis System And Method.

    DOEpatents

    Li, Qingbo; Zhou, Songsan; Liu, Changsheng

    2003-10-07

    A capillary electrophoresis system comprises capillaries positioned in parallel to each other forming a plane. The capillaries are configured to allow samples to migrate. A light source is configured to illuminate the capillaries and the samples therein. This causes the samples to emit light. A lens is configured to receive the light emitted by the samples and positioned directly over a first group of the capillaries and obliquely over a second group of the capillaries. The light source is further configured to illuminate the second group of capillaries more than the first group of the capillaries such that amount of light received by the lens from the first group of capillaries is substantially identical to amount of light received from the second group of capillaries when an identical amount of the samples is migrating through the first and second group capillaries.

  2. Determinants of linear judgment: a meta-analysis of lens model studies.

    PubMed

    Karelaia, Natalia; Hogarth, Robin M

    2008-05-01

    The mathematical representation of E. Brunswik's (1952) lens model has been used extensively to study human judgment and provides a unique opportunity to conduct a meta-analysis of studies that covers roughly 5 decades. Specifically, the authors analyzed statistics of the "lens model equation" (L. R. Tucker, 1964) associated with 249 different task environments obtained from 86 articles. On average, fairly high levels of judgmental achievement were found, and people were seen to be capable of achieving similar levels of cognitive performance in noisy and predictable environments. Further, the effects of task characteristics that influence judgment (numbers and types of cues, inter-cue redundancy, function forms and cue weights in the ecology, laboratory versus field studies, and experience with the task) were identified and estimated. A detailed analysis of learning studies revealed that the most effective form of feedback was information about the task. The authors also analyzed empirically under what conditions the application of bootstrapping--or replacing judges by their linear models--is advantageous. Finally, the authors note shortcomings of the kinds of studies conducted to date, limitations in the lens model methodology, and possibilities for future research. (Copyright) 2008 APA, all rights reserved.

  3. Rabbits' eye globe sonographic biometry.

    PubMed

    Toni, Maria Carolina; Meirelles, Adriana Érica Wilkes Burton; Gava, Fábio Nelson; Camacho, Aparecido Antônio; Laus, José Luiz; Canola, Júlio Carlos

    2010-11-01

    To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A-mode and B-mode ultrasound with a 20 MHz transducer. In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B-modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. The mean values obtained were 2.70 mm (± 0.22 mm) for D1, 7.32 mm (± 0.40 mm) for D2, 7.10 mm (± 0.45 mm) for D3 and 17.12 mm (± 0.41 mm) for D4. Statistical analyses using the Student's t-test showed that there were no differences between the eyes. The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits. © 2010 American College of Veterinary Ophthalmologists.

  4. Constraints on cosmological models from strong gravitational lensing systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Shuo; Pan, Yu; Zhu, Zong-Hong

    Strong lensing has developed into an important astrophysical tool for probing both cosmology and galaxies (their structure, formation, and evolution). Using the gravitational lensing theory and cluster mass distribution model, we try to collect a relatively complete observational data concerning the Hubble constant independent ratio between two angular diameter distances D{sub ds}/D{sub s} from various large systematic gravitational lens surveys and lensing by galaxy clusters combined with X-ray observations, and check the possibility to use it in the future as complementary to other cosmological probes. On one hand, strongly gravitationally lensed quasar-galaxy systems create such a new opportunity by combiningmore » stellar kinematics (central velocity dispersion measurements) with lensing geometry (Einstein radius determination from position of images). We apply such a method to a combined gravitational lens data set including 70 data points from Sloan Lens ACS (SLACS) and Lens Structure and Dynamics survey (LSD). On the other hand, a new sample of 10 lensing galaxy clusters with redshifts ranging from 0.1 to 0.6 carefully selected from strong gravitational lensing systems with both X-ray satellite observations and optical giant luminous arcs, is also used to constrain three dark energy models (ΛCDM, constant w and CPL) under a flat universe assumption. For the full sample (n = 80) and the restricted sample (n = 46) including 36 two-image lenses and 10 strong lensing arcs, we obtain relatively good fitting values of basic cosmological parameters, which generally agree with the results already known in the literature. This results encourages further development of this method and its use on larger samples obtained in the future.« less

  5. Geographical origin discrimination of lentils (Lens culinaris Medik.) using 1H NMR fingerprinting and multivariate statistical analyses.

    PubMed

    Longobardi, Francesco; Innamorato, Valentina; Di Gioia, Annalisa; Ventrella, Andrea; Lippolis, Vincenzo; Logrieco, Antonio F; Catucci, Lucia; Agostiano, Angela

    2017-12-15

    Lentil samples coming from two different countries, i.e. Italy and Canada, were analysed using untargeted 1 H NMR fingerprinting in combination with chemometrics in order to build models able to classify them according to their geographical origin. For such aim, Soft Independent Modelling of Class Analogy (SIMCA), k-Nearest Neighbor (k-NN), Principal Component Analysis followed by Linear Discriminant Analysis (PCA-LDA) and Partial Least Squares-Discriminant Analysis (PLS-DA) were applied to the NMR data and the results were compared. The best combination of average recognition (100%) and cross-validation prediction abilities (96.7%) was obtained for the PCA-LDA. All the statistical models were validated both by using a test set and by carrying out a Monte Carlo Cross Validation: the obtained performances were found to be satisfying for all the models, with prediction abilities higher than 95% demonstrating the suitability of the developed methods. Finally, the metabolites that mostly contributed to the lentil discrimination were indicated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Annotated Bibliography of Relative Sea Level Change

    DTIC Science & Technology

    1991-09-01

    Millennial Basis, Morner and Kui-len, eds., D. Reidel. Publishing Company, pp 571-604. Over the last few years, considerable attention has been given to...historic erosion rates. Curiously , the ability to model statistically the historic shore erosion rate is best on those reaches already substantially

  7. Cornea and ocular lens visualized with three-dimensional confocal microscopy

    NASA Astrophysics Data System (ADS)

    Masters, Barry R.

    1992-08-01

    This paper demonstrates the advantages of three-dimensional reconstruction of the cornea and the ocular crystalline lens by confocal microscopy and volume rendering computer techniques. The advantages of noninvasive observation of ocular structures in living, unstained, unfixed tissue include the following: the tissue is in a natural living state without the artifacts of fixation, mechanical sectioning, and staining; the three-dimensional structure can be observed from any view point and quantitatively analyzed; the dynamics of morphological changes can be studied; and the use of confocal microscopic observation results in a reduction of the number of animals required for ocular morphometric studies. The main advantage is that the dynamic morphology of ocular structures can be investigated in living ocular tissue. A laser scanning confocal microscope was used in the reflected light mode to obtain the two- dimensional images from the cornea and the ocular lens of a freshly enucleated rabbit eye. The light source was an argon ion laser with 488 nm wavelength. The microscope objective was a Leitz 25X, NA 0.6 water immersion lens. The 400 micron thick cornea was optically sectioned into 133, three micron sections. The semi-transparent cornea and the in-situ ocular lens was visualized as high resolution, high contrast two-dimensional images. The under sampling resulted in a three-dimensional visualization rendering in which the corneal thickness (z-axis) is compressed. The structures observed in the cornea include: superficial epithelial cells and their nuclei, basal epithelial cells and their `beaded' cell borders, basal lamina, nerve plexus, nerve fibers, free nerve endings in the basal epithelial cells, nuclei of stromal keratocytes, and endothelial cells. The structures observed in the in-situ ocular lens include: lens capsule, lens epithelial cells, and individual lens fibers.

  8. Characterization of lens based photoacoustic imaging system.

    PubMed

    Francis, Kalloor Joseph; Chinni, Bhargava; Channappayya, Sumohana S; Pachamuthu, Rajalakshmi; Dogra, Vikram S; Rao, Navalgund

    2017-12-01

    Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  9. Effects of Stress on Judgment and Decision Making in Dynamic Tasks

    DTIC Science & Technology

    1991-06-01

    their normal working conditions, (2) to ascertain whether the results from lens model theory and research in static tasks generalize to these...8217 normal work environment. A further generalization from lens model theory is that those precursors (secondary cues) that are more conceptual in...potential microburst cases. Although this sample of cases is admittedly smaller than desirable, many hours of technical work were required to remove

  10. Diagnostic system for measuring temperature, pressure, CO2 concentration and H2O concentration in a fluid stream

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Partridge, Jr., William P.; Jatana, Gurneesh Singh; Yoo, Ji-Hyung

    A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperaturesmore » derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.« less

  11. A 5mm catheter for constant resolution probing in Fourier domain optical coherence endoscopy

    NASA Astrophysics Data System (ADS)

    Lee, Kye-Sung; Wu, Lei; Xie, Huikai; Ilegbusi, Olusegun; Costa, Marco; Rolland, Jannick P.

    2007-02-01

    A 5mm biophotonic catheter was conceived for optical coherence tomography (OCT) with collimation optics, an axicon lens, and custom design imaging optics, yielding a 360 degree scan aimed at imaging within concave structures such as lung lobes. In OCT a large depth of focus is necessary to image a thick sample with a constant high transverse resolution. There are two approaches to achieving constant lateral resolution in OCT: Dynamic focusing or Bessel beam forming. This paper focuses on imaging with Bessel beams. A Bessel beam can be generated in the sample arm of the OCT interferometer when axicon optics is employed instead of a conventional focusing lens. We present a design for a 5mm catheter that combines an axicon lens with imaging optics and the coupling of a MEMS mirror attached to a micromotor that allow 360 degree scanning with a resolution of about 5 microns across a depth of focus of about 1.2mm.

  12. Diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Partridge, Jr., William P.; Jatana, Gurneesh Singh; Yoo, Ji Hyung

    A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperaturesmore » derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.« less

  13. Concept and design of charged particle optics using energy Fourier plane collimation

    NASA Astrophysics Data System (ADS)

    Yang, Guojun; Wei, Tao; Zhang, Zhuo; He, Xiaozhong; Zhang, Xiaoding; Li, Yiding; Shi, Jinshui

    2014-09-01

    Charged particle radiography has become a promising new approach in the field of transmission radiography because of the invention of the magnetic imaging lens. The using of the imaging lens makes it possible for thick objects to get significantly improved transmission radiography. Currently, the conventional charged particle radiography only uses the information of the flux attenuation and the angular scattering of the transmitted particles to determine the properties of the sample. However, the energy loss of the incident particles introduced by ionizations throughout the object limits the spatial resolution of the image because of the chromatic blur. In this paper a new concept of imaging lens that uses the information of the energy loss is proposed. With a specially designed imaging lens, the information of the energy loss could result in apparent contrast in the final image. This design procedure of the energy loss imaging lens is presented, and a preliminary design is verified by numerical simulations. Experimental demonstration is also expected on a cyclotron at the Institute of Fluid Physics, CAEP.

  14. Preliminary Evaluation of Visual and Flight Performance of Three Current Multifocal Contact Lens Designs for Presbyopic US Army Aviators

    DTIC Science & Technology

    2005-01-01

    absolute emmetropia. Up to a substantial 25% of the aviation population develops ametropia requiring the use of spectacles or other refractive correction...to determine statistical differences in visual performance. The types of contact lenses were compared in general to determine whether there was any...Lomb multi- focal, and 187 (sd=25) for the Ciba progressive. There was not a statistically significant difference for high luminance contrast

  15. Effects of hyperbaric oxygen on crystalline lens and retina in nicotine-exposed rats.

    PubMed

    Ari, Seyhmus; Nergiz, Yusuf; Cingü, Abdullah Kürşat; Atay, Ahmet Engin; Sahin, Alparslan; Cinar, Yasin; Caca, Ihsan

    2013-03-01

    To determine histopathological changes on crystalline lens and retina of rats after subcutaneous injection of nicotine and to examine the effects of hyperbaric oxygen (HBO) on these changes related to nicotine exposure. Twenty-eight female Sprague-Dawley rats were enrolled in the study and the rats were divided into four equal sized groups randomly (Group N: the rats exposed only to nicotine, group HB: the rats received only HBO, group N+HB: the rats that underwent to nicotine injection and subsequently received HBO, group C: the control group that neither exposed to nicotine nor received HBO). The rats were sacrificed by decapitation method and all were enucleated immediately after scarification. Tissue samples from crystalline lens, lens capsule, and the retina from the right eyes of the rats were examined by light microscopy. While the histological appearances of the retina and the lens was similar in group HB, group N+HB, and the control group; group N showed some pathological changes like decrement in the retinal ganglion cell density, atrophy of the retinal nerve fiber layer, congestion of the vessels in the optic nerve head, thinning of the internal plexiform layer, thinning of the lens capsule, and transformation of the anterior subcapsular epithelium into squamous epithelia. Subcutaneous injection of nicotine was found to be related with some pathological changes in the retina and lens of the Sprague-Dawley rats. However HBO caused no significant negative effect. Furthermore, the histopathological changes related to nicotine exposure in the lens and retina of the rats recovered by the application of HBO.

  16. The effect of Gonioscopy on keratometry and corneal surface topography.

    PubMed

    George, Mathew K; Kuriakose, Thomas; DeBroff, Brian M; Emerson, John W

    2006-06-17

    Biometric procedures such as keratometry performed shortly after contact procedures like gonioscopy and applanation tonometry could affect the validity of the measurement. This study was conducted to understand the short-term effect of gonioscopy on corneal curvature measurements and surface topography based Simulated Keratometry and whether this would alter the power of an intraocular lens implant calculated using post-gonioscopy measurements. We further compared the effect of the 2-mirror (Goldmann) and the 4-mirror (Sussman) Gonioscopes. A prospective clinic-based self-controlled comparative study. 198 eyes of 99 patients, above 50 years of age, were studied. Exclusion criteria included documented dry eye, history of ocular surgery or trauma, diabetes mellitus and connective tissue disorders. Auto-Keratometry and corneal topography measurements were obtained at baseline and at three follow-up times - within the first 5 minutes, between the 10th-15th minute and between the 20th-25th minute after intervention. One eye was randomized for intervention with the 2-mirror gonioscope and the other underwent the 4-mirror after baseline measurements. t-tests were used to examine differences between interventions and between the measurement methods. The sample size was calculated using an estimate of clinically significant lens implant power changes based on the SRK-II formula. Clinically and statistically significant steepening was observed in the first 5 minutes and in the 10-15 minute interval using topography-based Sim K. These changes were not present with the Auto-Keratometer measurements. Although changes from baseline were noted between 20 and 25 minutes topographically, these were not clinically or statistically significant. There was no significant difference between the two types of gonioscopes. There was greater variability in the changes from baseline using the topography-based Sim K readings. Reversible steepening of the central corneal surface is produced by the act of gonioscopy as measured by Sim K, whereas no significant differences were present with Auto-K measurements. The type of Gonioscope used does not appear to influence these results. If topographically derived Sim K is used to calculate the power of the intraocular lens implant, we recommend waiting a minimum of 20 minutes before measuring the corneal curvature after gonioscopy with either Goldmann or Sussman contact lenses.

  17. The effect of Gonioscopy on keratometry and corneal surface topography

    PubMed Central

    George, Mathew K; Kuriakose, Thomas; DeBroff, Brian M; Emerson, John W

    2006-01-01

    Background Biometric procedures such as keratometry performed shortly after contact procedures like gonioscopy and applanation tonometry could affect the validity of the measurement. This study was conducted to understand the short-term effect of gonioscopy on corneal curvature measurements and surface topography based Simulated Keratometry and whether this would alter the power of an intraocular lens implant calculated using post-gonioscopy measurements. We further compared the effect of the 2-mirror (Goldmann) and the 4-mirror (Sussman) Gonioscopes. Methods A prospective clinic-based self-controlled comparative study. 198 eyes of 99 patients, above 50 years of age, were studied. Exclusion criteria included documented dry eye, history of ocular surgery or trauma, diabetes mellitus and connective tissue disorders. Auto-Keratometry and corneal topography measurements were obtained at baseline and at three follow-up times – within the first 5 minutes, between the 10th-15th minute and between the 20th-25th minute after intervention. One eye was randomized for intervention with the 2-mirror gonioscope and the other underwent the 4-mirror after baseline measurements. t-tests were used to examine differences between interventions and between the measurement methods. The sample size was calculated using an estimate of clinically significant lens implant power changes based on the SRK-II formula. Results Clinically and statistically significant steepening was observed in the first 5 minutes and in the 10–15 minute interval using topography-based Sim K. These changes were not present with the Auto-Keratometer measurements. Although changes from baseline were noted between 20 and 25 minutes topographically, these were not clinically or statistically significant. There was no significant difference between the two types of gonioscopes. There was greater variability in the changes from baseline using the topography-based Sim K readings. Conclusion Reversible steepening of the central corneal surface is produced by the act of gonioscopy as measured by Sim K, whereas no significant differences were present with Auto-K measurements. The type of Gonioscope used does not appear to influence these results. If topographically derived Sim K is used to calculate the power of the intraocular lens implant, we recommend waiting a minimum of 20 minutes before measuring the corneal curvature after gonioscopy with either Goldmann or Sussman contact lenses. PMID:16780595

  18. Coherent radar imaging: Signal processing and statistical properties

    NASA Astrophysics Data System (ADS)

    Woodman, Ronald F.

    1997-11-01

    The recently developed technique for imaging radar scattering irregularities has opened a great scientific potential for ionospheric and atmospheric coherent radars. These images are obtained by processing the diffraction pattern of the backscattered electromagnetic field at a finite number of sampling points on the ground. In this paper, we review the mathematical relationship between the statistical covariance of these samples, (? ?†), and that of the radiating object field to be imaged, (??†), in a self-contained and comprehensive way. It is shown that these matrices are related in a linear way by (??†) = aM(FF†)M†a*, where M is a discrete Fourier transform operator and a is a matrix operator representing the discrete and limited sampling of the field. The image, or brightness distribution, is the diagonal of (FF†). The equation can be linearly inverted only in special cases. In most cases, inversion algorithms which make use of a priori information or maximum entropy constraints must be used. A naive (biased) "image" can be estimated in a manner analogous to an optical camera by simply applying an inverse DFT operator to the sampled field ? and evaluating the average power of the elements of the resulting vector ?. Such a transformation can be obtained either digitally or in an analog way. For the latter we can use a Butler matrix consisting of properly interconnected transmission lines. The case of radar targets in the near field is included as a new contribution. This case involves an additional matrix operator b, which is an analog of an optical lens used to compensate for the curvature of the phase fronts of the backscattered field. This "focusing" can be done after the statistics have been obtained. The formalism is derived for brightness distributions representing total powers. However, the derived expressions have been extended to include "color" images for each of the frequency components of the sampled time series. The frequency filtering is achieved by estimating spectra and cross spectra of the sample time series, in lieu of the power and cross correlations used in the derivation.

  19. Photometric microlensing and stellar mass determination

    NASA Astrophysics Data System (ADS)

    Samadi, R.

    Microlensing was suggested for stellar mass determination of nearby stars by several authors (e.g. Paczynski 1995 and Miralada-Escude 1996). There are two aspects in gravitational microlensing: photometry and astrometry. Here only the photometric aspect -i.e. magnification of a background source by a stellar lens- will be considered. The first study in this domain was done by Paczyński (1995). An attempt to investigate some observational constraints (Alard et al. 1996), takes its origin in this study. It will be shown here that blending of the source by the lens, not only induces a degeneracy which has been pointed out by Wozniak and Paczynski (1997) and can be removed by measuring the flux of the source outside the microlensing event, but also strongly reduces the photometric cross section as well as the duration of microlensing events. The expected number of events decreases strongly with blending. Blending effects can be reduced by selecting faint lens candidates. Unfortunately however, it is difficult to monitor a sufficient number of lens candidates per night, and restricting oneself to nearby and high proper motion objects would lead to a very small number of lens candidates. In the case of short duration events, the light curve must be sampled at short time intervals. When sampling daily, the condition is very strong and the expected rate of events very small. Observing from space would increase significantly the rate, but this gain is still insufficient. We conclude that the event rate will be very small and that the project does not seem to be feasible at least under current observing conditions and even in the near future.

  20. Atomic force microscopy and Langmuir–Blodgett monolayer technique to assess contact lens deposits and human meibum extracts☆

    PubMed Central

    Hagedorn, Sarah; Drolle, Elizabeth; Lorentz, Holly; Srinivasan, Sruthi; Leonenko, Zoya; Jones, Lyndon

    2015-01-01

    Purpose The purpose of this exploratory study was to investigate the differences in meibomian gland secretions, contact lens (CL) lipid extracts, and CL surface topography between participants with and without meibomian gland dysfunction (MGD). Methods Meibum study: Meibum was collected from all participants and studied via Langmuir–Blodgett (LB) deposition with subsequent Atomic Force Microscopy (AFM) visualization and surface roughness analysis. CL Study: Participants with and without MGD wore both etafilcon A and balafilcon A CLs in two different phases. CL lipid deposits were extracted and analyzed using pressure-area isotherms with the LB trough and CL surface topographies and roughness values were visualized using AFM. Results Meibum study: Non-MGD participant meibum samples showed larger, circular aggregates with lower surface roughness, whereas meibum samples from participants with MGD showed more lipid aggregates, greater size variability and higher surface roughness. CL Study: Worn CLs from participants with MGD had a few large tear film deposits with lower surface roughness, whereas non-MGD participant-worn lenses had many small lens deposits with higher surface roughness. Balafilcon A pore depths were shallower in MGD participant worn lenses when compared to non-MGD participant lenses. Isotherms of CL lipid extracts from MGD and non-MGD participants showed a seamless rise in surface pressure as area decreased; however, extracts from the two different lens materials produced different isotherms. Conclusions MGD and non-MGD participant-worn CL deposition were found to differ in type, amount, and pattern of lens deposits. Lipids from MGD participants deposited irregularly whereas lipids from non-MGD participants showed more uniformity. PMID:25620317

  1. Bacterial populations on silicone hydrogel and hydrogel contact lenses after swimming in a chlorinated pool.

    PubMed

    Choo, Jennifer; Vuu, Kathy; Bergenske, Peter; Burnham, Kara; Smythe, Jennifer; Caroline, Patrick

    2005-02-01

    A number of reports have indicated an association between swimming with contact lenses and subsequent eye infection. This study tests whether a hydrophilic contact lens worn while swimming accumulates bacteria present in the water. It was of interest to determine whether lens type (silicone hydrogel vs. hydrogel) affected the result. Fifteen healthy noncontact lens wearers swam for 30 minutes with a silicone hydrogel lens (PureVision, Bausch & Lomb, Rochester, NY) on one eye and a hydrogel lens (Acuvue 2, Vistakon Inc., Jacksonville, FL) on the other. Lenses were removed aseptically and placed in sterile vials 10 minutes after the subjects left the water. Microbial growth was enumerated for total numbers of colonies and categorized by species present. Numbers of colonies were compared between the two lens groups and with a water sample taken from the pool at the time of the experiment. Eight of the subjects returned on a different day and wore new lenses for 50 minutes in normal room conditions. Two lenses were lost while swimming. Twenty-seven of the remaining 28 lenses worn while swimming showed colonization, principally with Staphylococcus epidermidis, which was also by far the most common species identified from the water itself. Small numbers of Staphylococcus aureus and Streptococcus salivarius were also present in the water and on the lenses. Numbers of colonies varied among subjects (range, 0 to 230), but no differences were observed between the two lens groups. Lenses removed after 30 minutes of wear without swimming were mostly sterile, with 3 of 16 lenses showing just two colonies each. It appears that wearing a hydrophilic lens while swimming allows accumulation of microbial organisms on or in the lens, regardless of lens material. Swimmers should be advised to wear tight-fitting goggles if lenses are worn while swimming, and thorough disinfection of the lenses before overnight wear seems prudent.

  2. Measuring the viscosity of whole bovine lens using a fiber optic oxygen sensing system

    PubMed Central

    Thao, Mai T.; Perez, Daniel; Dillon, James

    2014-01-01

    Purpose To obtain a better understanding of oxygen and nutrient transport within the lens, the viscosity of whole lenses was investigated using a fiber optic oxygen sensor (optode). The diffusion coefficient of oxygen was calculated using the Stokes-Einstein equation at the slip boundary condition. Methods The optode was used to measure the oxygen decay signal in samples consisting of different glycerol/water solutions with known viscosities. The oxygen decay signal was fitted to a double exponential decay rate equation, and the lifetimes (tau) were calculated. It was determined that the tau-viscosity relationship is linear, which served as the standard curve. The same procedure was applied to fresh bovine lenses, and the unknown viscosity of the bovine lens was calculated from the tau-viscosity relationship. Results The average viscosity in a whole bovine lens was determined to be 5.74±0.88 cP by our method. Using the Stokes-Einstein equation at the slip boundary condition, the diffusion coefficient for oxygen was calculated to be 8.2 × 10−6 cm2/s. Conclusions These data indicate a higher resistance to flow for oxygen and nutrients in the lens than what is currently assumed in the literature. Overall, this study allows a better understanding of oxygen transport within the lens. PMID:24505211

  3. Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system.

    PubMed

    Sookpeng, Supawitoo; Butdee, Chitsanupong

    2017-06-01

    The study aimed to evaluate the image quality in terms of signal-to-noise ratio (SNR) and dose to the lens of the eye and the other nearby organs from the CT brain scan using an automatic tube current modulation (ATCM) system with or without CT gantry tilt is needed. An anthropomorphic phantom was scanned with different settings including use of different ATCM, fixed tube current time product (mAs) settings and degree angles of gantry tilt. Gafchromic film XR-QA2 was used to measure absorbed dose of the organs. Relative doses and SNR for the various scan settings were compared with the reference setting of the fixed 330 mAs. Average absorbed dose for the lens of the eyes varied from 8.7 to 21.7 mGy. The use of the ATCM system with the gantry tilt resulted in up to 60% decrease in the dose to the lens of the eye. SNR significantly decreased while tilting the gantry using the fixed mAs techniques, compared to that of the reference setting. However, there were no statistical significant differences for SNRs between the reference setting and all ATCM settings. Compared to the reference setting of the fixed effective mAs, using the ATCM system and appropriate tilting, the gantry resulted in a substantial decrease in the dose to the lens of the eye while preserving signal-to-noise ratio. CT brain examination should be carefully controlled to optimize dose for lens of the eye and image quality of the examination.

  4. Peripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design.

    PubMed

    Pauné, J; Queiros, A; Quevedo, L; Neves, H; Lopes-Ferreira, D; González-Méijome, J M

    2014-12-01

    To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses. Both experimental lenses were able to increase significantly the relative peripheral myopic defocus up to -0.50 D in the nasal field and -1.00 D in the temporal field (p<0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5mm pupil size (p<0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p>0.05). RGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Reliability of a Single Light Source Purkinjemeter in Pseudophakic Eyes.

    PubMed

    Janunts, Edgar; Chashchina, Ekaterina; Seitz, Berthold; Schaeffel, Frank; Langenbucher, Achim

    2015-08-01

    To study the reliability of Purkinje image analysis for assessment of intraocular lens tilt and decentration in pseudophakic eyes. The study comprised 64 eyes of 39 patients. All eyes underwent phacoemulsification with intraocular lens implanted in the capsular bag. Lens decentration and tilt were measured multiple times by an infrared Purkinjemeter. A total of 396 measurements were performed 1 week and 1 month postoperatively. Lens tilt (Tx, Ty) and decentration (Dx, Dy) in horizontal and vertical directions, respectively, were calculated by dedicated software based on regression analysis for each measurement using only four images, and afterward, the data were averaged (mean values, MV) for repeated sequence of measurements. New software was designed by us for recalculating lens misalignment parameters offline, using a complete set of Purkinje images obtained through the repeated measurements (9 to 15 Purkinje images) (recalculated values, MV'). MV and MV' were compared using SPSS statistical software package. MV and MV' were found to be highly correlated for the Tx and Ty parameters (R2 > 0.9; p < 0.001), moderately correlated for the Dx parameter (R2 > 0.7; p < 0.001), and weakly correlated for the Dy parameter (R2 = 0.23; p < 0.05). Reliability was high (Cronbach α > 0.9) for all measured parameters. Standard deviation values were 0.86 ± 0.69 degrees, 0.72 ± 0.65 degrees, 0.04 ± 0.05 mm, and 0.23 ± 0.34 mm for Tx, Ty, Dx, and Dy, respectively. The Purkinjemeter demonstrated high reliability and reproducibility for lens misalignment parameters. To further improve reliability, we recommend capturing at least six Purkinje images instead of three.

  6. A randomized trial of adding a plano lens to atropine for amblyopia.

    PubMed

    Wallace, David K; Lazar, Elizabeth L; Repka, Michael X; Holmes, Jonathan M; Kraker, Raymond T; Hoover, Darren L; Weise, Katherine K; Waters, Amy L; Rice, Melissa L; Peters, Robert J

    2015-02-01

    Some children have residual amblyopia after treatment with atropine eyedrops for amblyopia due to strabismus and/or anisometropia. We conducted a randomized clinical trial to evaluate the effectiveness of augmenting the effect of atropine by changing the lens over the fellow eye to plano in children with residual amblyopia. A total of 73 children 3 to <8 years of age (mean, 5.8 years) with stable residual amblyopia (range, 20/32 to 20/160, mean 20/63(+1)) were enrolled after at least 12 weeks of atropine treatment of the fellow eye. Participants were randomly assigned to continuing weekend atropine alone or wearing a plano lens over the fellow eye (while continuing atropine). The primary outcome was assessed at 10 weeks, and participants were followed until improvement ceased. At the 10-week primary outcome visit, amblyopic-eye visual acuity had improved an average of 1.1 lines with the plano lens and 0.6 lines with atropine only (difference adjusted for baseline visual acuity = + 0.5 line; 95% CI, -0.1 to +1.2). At the primary outcome or later visit when the best-measured visual acuity was observed, the mean amblyopic-eye improvement from baseline was 1.9 lines with the plano lens and 0.8 lines with atropine only. When amblyopic-eye visual acuity stops improving with atropine treatment, there may be a small benefit to augmenting atropine therapy with a plano lens over the fellow eye. However, the effect was not statistically significant, and the large confidence interval raises the possibility of no benefit or a benefit larger than we observed. A larger study would be necessary to get a more precise estimate of the treatment effect. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  7. Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs.

    PubMed

    Gundersen, Kjell G; Potvin, Rick

    2017-01-01

    To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire. Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of -1.0 D (FV better, P =0.02), -1.5 and -2.00 D (PX better, P <0.01 for both). Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm ( P <0.01) with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens ( P =0.04). There were no statistically significant differences by lens for low contrast VA ( P =0.1) or for quality of vision measures ( P >0.3). Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs.

  8. A Randomized Controlled Trial of Tong Len Meditation Practice in Cancer Patients: Evaluation of a Distant Psychological Healing Effect.

    PubMed

    Pagliaro, Gioacchino; Pandolfi, Paolo; Collina, Natalina; Frezza, Giovanni; Brandes, Alba; Galli, Margherita; Avventuroso, Federica Marzocchi; De Lisio, Sara; Musti, Muriel Assunta; Franceschi, Enrico; Esposti, Roberta Degli; Lombardo, Laura; Cavallo, Giovanna; Di Battista, Monica; Rimondini, Simonetta; Poggi, Rosalba; Susini, Cinzia; Renzi, Rina; Marconi, Linda

    2016-01-01

    Tong Len meditation is an important therapeutic tool in the Tibetan medicine, and it can be used for self-healing and/or to heal others. Currently, in the West, there is no scientific study concerning the efficacy of a Tong Len distant healing effect on psychological disorders in cancer patients. To evaluate a distant healing effect of Tong Len meditation on stress, anxiety, depression, fatigue, and self-perceived quality of life in cancer patients. These psychological objectives were chosen as a consequence of the limited scientific literature of present day. We performed a double-blind randomized controlled trial on 103 cancer patients with tumors. Overall, 12 meditators used Tong Len in aid of 52 patients randomly selected as experimental group, while the remaining 51 patients constituted the control group. Patients and meditators did not know each other. All patients completed profile of mood states (POMS) and European Quality of Life-5 dimensions (EQ-5D) questionnaires before treatment (T0), after two (T1) and three months of treatment (T2), and one month after treatment cessation (T3). With regard to the parameters related to depression, a statistically significant improvement (P = .003) was observed in the treatment group compared to controls. On the other hand, the vigor/activity parameter saw significant improvements in the control group (P = .009). Both groups exhibited significant improvements in the other factors assessed in the POMS and EQ-5D questionnaires. This study did not provide sufficient evidence supporting an efficacy of Tong Len meditation in distant psychological healing as compared to a control condition. The research highlighted some psychological improvements through Tong Len distant meditation in a group of patients unknown to meditators. Therefore, the enhancement detected in most parameters in both treatment and control groups raises interest on in-depth analysis and evaluation of distant meditation on cancer patients to mitigate psychological problems caused by the disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. A test of lens opacity as an indicator of preclinical Alzheimer Disease.

    PubMed

    Bei, Ling; Shui, Ying-Bo; Bai, Fang; Nelson, Suzanne K; Van Stavern, Gregory P; Beebe, David C

    2015-11-01

    Previous studies reported that characteristic lens opacities were present in Alzheimer Disease (AD) patients postmortem. We therefore determined whether cataract grade or lens opacity is related to the risk of Alzheimer dementia in participants who have biomarkers that predict a high risk of developing the disease. AD biomarker status was determined by positron emission tomography-Pittsburgh compound B (PET-PiB) imaging and cerebrospinal fluid (CSF) levels of Aβ42. Cognitively normal participants with a clinical dementia rating of zero (CDR = 0; N = 40) or with slight evidence of dementia (CDR = 0.5; N = 2) were recruited from longitudinal studies of memory and aging at the Washington University Knight Alzheimer's Disease Research Center. The age, sex, race, cataract type and cataract grade of all participants were recorded and an objective measure of lens light scattering was obtained for each eye using a Scheimpflug camera. Twenty-seven participants had no biomarkers of Alzheimer dementia and were CDR = 0. Fifteen participants had biomarkers indicating increased risk of AD, two of which were CDR = 0.5. Participants who were biomarker positive were older than those who were biomarker negative. Biomarker positive participants had more advanced cataracts and increased cortical light scattering, none of which reached statistical significance after adjustment for age. We conclude that cataract grade or lens opacity is unlikely to provide a non-invasive measure of the risk of developing Alzheimer dementia. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Evolution of light scattering and redox balance in the rat lens after in vivo exposure to close-to-threshold dose ultraviolet radiation.

    PubMed

    Wang, Jing; Löfgren, Stefan; Dong, Xiuqin; Galichanin, Konstantin; Söderberg, Per G

    2010-11-01

    To investigate the evolution of cataract development and glutathione redox balance in the rat lens after in vivo close-to-threshold dose exposure to ultraviolet radiation (UVR) around 300 nm. Three groups of 10 Sprague-Dawley rats were unilaterally exposed to 8 kJ/m² UVR-300 nm for 15 min, and a fourth group of 10 rats was kept without UVR exposure as nonexposed control animals. The exposed animals were killed at 1, 3 and 7 days after exposure. Both lenses from all animals were extracted and photographed and the intensity of forward light scattering was measured quantitatively. Thereafter, the lenses were homogenized. The concentration of reduced glutathione (GSH) and oxidized glutathione (GSSG), and the activity of glutathione reductase (GR) and glutathione peroxidase (GPx), respectively, were determined spectrophotometrically. The mean paired differences between exposed and nonexposed lenses were used as primary data in the statistical analyses. All exposed lenses developed cataract. Lens light scattering increased throughout the 7 days after UVR exposure. GSH concentration and GPx rate transiently increased at 1 day after exposure and then decreased throughout follow-up, with GSH concentration having a negative balance at the end. GSSG concentration and GR activity did not change after UVR exposure. In vivo close-to-threshold UVR exposure induces a gradual increase in rat lens opacification/cataract development and time dependently alters the redox balance in the lens. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  11. Adhesion of Pseudomonas aeruginosa and Staphylococcus epidermidis to silicone-hydrogel contact lenses.

    PubMed

    Henriques, Mariana; Sousa, Cláudia; Lira, Madalena; Elisabete, M; Oliveira, Real; Oliveira, Rosário; Azeredo, Joana

    2005-06-01

    The purpose of this study is to compare the adhesion capabilities of the most important etiologic agents of microbial ocular infection to the recently available silicone-hydrogel lenses with those to a conventional hydrogel lens. In vitro static adhesion assays of Pseudomonas aeruginosa 10,145, Staphylococcus epidermidis 9142 (biofilm-positive), and 12,228 (biofilm-negative) to two extended-wear silicone-hydrogel lenses (balafilcon A and lotrafilcon A), a daily wear silicone-hydrogel lens (galyfilcon A) and a conventional hydrogel (etafilcon A) were performed. To interpret the adhesion results, lens surface relative hydrophobicity was assessed by water contact angle measurements. P. aeruginosa and S. epidermidis 9142 exhibited greater adhesion capabilities to the extended wear silicone-hydrogel lenses than to the daily wear silicone- and conventional hydrogel lenses (p < 0.05). No statistical differences were found between the adhesion extent of these strains to galyfilcon A and etafilcon A. The biofilm negative strain of S. epidermidis adhered in larger extents to the silicone-hydrogel lenses than to the conventional hydrogel (p < 0.05), but in much lower amounts than the biofilm-positive strain. The water contact angle measurements revealed that the extended wear silicone-hydrogel lenses are hydrophobic, whereas the daily wear silicone- and conventional hydrogel lenses are hydrophilic. As a result of their hydrophobicity, the extended wear silicone-hydrogel lenses (lotrafilcon A and balafilcon A) may carry higher risk of microbial contamination than both the hydrophilic daily wear silicone-hydrogel lens, galyfilcon A and the conventional hydrogel lens, etafilcon A.

  12. Resistance of Acanthamoeba cysts to disinfection in multiple contact lens solutions.

    PubMed

    Johnston, Stephanie P; Sriram, Rama; Qvarnstrom, Yvonne; Roy, Sharon; Verani, Jennifer; Yoder, Jonathan; Lorick, Suchita; Roberts, Jacquelin; Beach, Michael J; Visvesvara, Govinda

    2009-07-01

    Acanthamoebae are free-living amoebae found in the environment, including soil, freshwater, brackish water, seawater, hot tubs, and Jacuzzis. Acanthamoeba species can cause keratitis, a painful vision-threatening infection of the cornea, and fatal granulomatous encephalitis in humans. More than 20 species of Acanthamoeba belonging to morphological groups I, II, and III distributed in 15 genotypes have been described. Among these, Acanthamoeba castellanii, A. polyphaga, and A. hatchetti are frequently identified as causing Acanthamoeba keratitis (AK). Improper contact lens care and contact with nonsterile water while wearing contact lenses are known risk factors for AK. During a recent multistate outbreak, AK was found to be associated with the use of Advanced Medical Optics Complete MoisturePlus multipurpose contact lens solution, which was hypothesized to have had insufficient anti-Acanthamoeba activity. As part of the investigation of that outbreak, we compared the efficacies of 11 different contact lens solutions against cysts of A. castellanii, A. polyphaga, and A. hatchetti (the isolates of all species were genotype T4), which were isolated in 2007 from specimens obtained during the outbreak investigation. The data, generated with A. castellanii, A. polyphaga, and A. hatchetti cysts, suggest that the two contact lens solutions containing hydrogen peroxide were the only solutions that showed any disinfection ability, with 0% and 66% growth, respectively, being detected with A. castellanii and 0% and 33% growth, respectively, being detected with A. polyphaga. There was no statistically significant difference in disinfection efficacy between the 11 solutions for A. hatchetti.

  13. Natural and anthropic processes controlling groundwater hydrogeochemistry in a tourist destination in northeastern Brazil.

    PubMed

    Mattos, Jonatas Batista; Cruz, Manoel Jerônimo Moreira; De Paula, Francisco Carlos Fernandes; Sales, Elinaldo Fonseca

    2018-06-12

    The objective of this study was to analyze spatial-seasonal changes to identify the natural and anthropic processes that control groundwater hydrogeochemistry in urban aquifers in municipality of Lençóis (Bahia). Tourism is the main activity of this municipality, which is an important tourist destination in northeastern Brazil and which maintains its tourism infrastructure by using groundwater. Two field campaigns were conducted (dry and rainy seasons) in order to collect groundwater samples extracted from 15 tubular wells distributed over the urban area of the municipality. The Piper diagram, multivariate statistical analyses, and artificial neural networks indicated that there are two types of water (Na-Cl and Na-[Formula: see text] - ), which were divided into five different clusters. Seasonal variation was observed to significantly alter groundwater hydrogeochemistry. According to the Gibbs diagram, groundwater within the urban area of Lençóis belonged to the rainfall dominance, demonstrating low water-rock interaction. Hydrogeochemical modeling results suggested hydrolysis as the main natural factors controlling process. However, mineral dissolution also occurred in one of the clusters. Human-originated trace contamination by nitrate, chloride, and sulfate occurred in a zone of the urban area. This contamination was observed regardless of climate seasonality, indicating that the main controlling process for groundwater hydrochemistry in this region is wastewater mobilization (indirect artificial recharge).

  14. First Sampling Hole in Mount Sharp

    NASA Image and Video Library

    2014-09-25

    This image from the Mars Hand Lens Imager MAHLI camera on NASA Curiosity Mars rover shows the first sample-collection hole drilled in Mount Sharp, the layered mountain that is the science destination of the rover extended mission.

  15. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, Yiping; Bolton, Adam S.; Montero-Dorta, Antonio D.

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thoroughmore » exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.« less

  16. The Application of Globular Water-Atomized Iron Powders for Additive Manufacturing by a LENS Technique

    PubMed Central

    Ziętala, Michał; Antolak-Dudka, Anna; Paserin, Vlad

    2018-01-01

    The water-atomized ATOMET 28, 1001, 4701, and 4801 powders, manufactured by Rio Tinto Metal Powders, were used for additive manufacturing by a laser engineered net shaping (LENS) technique. Their overall morphology was globular and rounded with a size distribution from about 20 to 200 µm. Only the ATOMET 28 powder was characterized by a strong inhomogeneity of particle size and irregular polyhedral shape of powder particles with sharp edges. The powders were pre-sieved to a size distribution from 40 to 150 µm before LENS processing. One particular sample—LENS-fabricated from the ATOMET 28 powder—was characterized by the largest cross-sectional (2D) porosity of 4.2% and bulk porosity of 3.9%, the latter determined by microtomography measurements. In contrast, the cross-sectional porosities of bulk, solid, nearly cubic LENS-fabricated samples from the other ATOMET powders exhibited very low porosities within the range 0.03–0.1%. Unexpectedly, the solid sample—LENS-fabricated from the reference, a purely spherical Fe 99.8 powder—exhibited a porosity of 1.1%, the second largest after that of the pre-sieved, nonspherical ATOMET 28 powder. Vibrations incorporated mechanically into the LENS powder feeding system substantially improved the flow rate vs. feeding rate dependence, making it completely linear with an excellent coefficient of fit, R2 = 0.99. In comparison, the reference powder Fe 99.8 always exhibited a linear dependence of the powder flow rate vs. feeding rate, regardless of vibrations. PMID:29783704

  17. Statistical Tools for Fitting Models of the Population Consequences of Acoustic Disturbance to Data from Marine Mammal Populations (PCAD Tools II)

    DTIC Science & Technology

    2014-09-30

    Consequences of Acoustic Disturbance to Data from Marine Mammal Populations (PCAD Tools II) Len Thomas, John Harwood, Catriona Harris, and Robert S... mammals changes over time. This project will develop statistical tools to allow mathematical models of the population consequences of acoustic...disturbance to be fitted to data from marine mammal populations. We will work closely with Phase II of the ONR PCAD Working Group, and will provide

  18. Focusing cosmic telescopes: systematics of strong lens modeling

    NASA Astrophysics Data System (ADS)

    Johnson, Traci Lin; Sharon, Keren q.

    2018-01-01

    The use of strong gravitational lensing by galaxy clusters has become a popular method for studying the high redshift universe. While diverse in computational methods, lens modeling techniques have grasped the means for determining statistical errors on cluster masses and magnifications. However, the systematic errors have yet to be quantified, arising from the number of constraints, availablity of spectroscopic redshifts, and various types of image configurations. I will be presenting my dissertation work on quantifying systematic errors in parametric strong lensing techniques. I have participated in the Hubble Frontier Fields lens model comparison project, using simulated clusters to compare the accuracy of various modeling techniques. I have extended this project to understanding how changing the quantity of constraints affects the mass and magnification. I will also present my recent work extending these studies to clusters in the Outer Rim Simulation. These clusters are typical of the clusters found in wide-field surveys, in mass and lensing cross-section. These clusters have fewer constraints than the HFF clusters and thus, are more susceptible to systematic errors. With the wealth of strong lensing clusters discovered in surveys such as SDSS, SPT, DES, and in the future, LSST, this work will be influential in guiding the lens modeling efforts and follow-up spectroscopic campaigns.

  19. Sequential and combinatorial roles of maf family genes define proper lens development.

    PubMed

    Reza, Hasan Mahmud; Urano, Atsuyo; Shimada, Naoko; Yasuda, Kunio

    2007-01-16

    Maf proteins have been shown to play pivotal roles in lens development in vertebrates. The developing chick lens expresses at least three large Maf proteins. However, the transcriptional relationship among the three large maf genes and their various roles in transactivating the downstream genes largely remain to be elucidated. Chick embryos were electroporated with wild-type L-maf, c-maf, and mafB by in ovo electroporation, and their effects on gene expression were determined by in situ hybridization using specific probes or by immunostaining. Endogenous gene expression was determined using nonelectroporated samples. A regulation mechanism exists among the members of maf family gene. An early-expressed member of this gene family typically stimulates the expression of later-expressed members. We also examined the regulation of various lens-expressing genes with a focus on the interaction between different Maf proteins. We found that the transcriptional ability of Maf proteins varies, even when the target is the same, in parallel with their discrete functions. L-Maf and c-Maf have no effect on E-cadherin expression, whereas MafB enhances its expression and thereby impedes lens vesicle formation. This study also revealed that Maf proteins can regulate the expression of gap junction genes, connexins, and their interacting partner, major intrinsic protein (MIP), during lens development. Misexpression of L-Maf and c-Maf induces ectopic expression of Cx43 and MIP; in contrast, MafB appears to have no effect on Cx43, but induces MIP significantly as evidenced from our gain-of-function experiments. Our results indicate that large Maf function is indispensable for chick lens initiation and development. In addition, L-Maf positively regulates most of the essential genes in this program and directs a series of molecular events leading to proper formation of the lens.

  20. Conjunctival epithelial flap in continuous contact lens wear.

    PubMed

    Graham, Andrew D; Truong, Tan N; Lin, Meng C

    2009-04-01

    Composed of sheets of cells detached from the underlying conjunctiva, conjunctival epithelial flap (CEF) is a recently reported phenomenon associated with contact lens wear with potential consequences for ocular health. Although CEF is generally asymptomatic, it is not known to what extent it might increase the longer-term risk of discomfort, inflammatory response, or infection. In this study, we use survival analysis methods to obtain unbiased estimates of the probability of developing CEF, the mean survival time free of CEF, and the effects of age, gender, ethnicity, and contact lens type. Two hundred four subjects were recruited for a continuous wear (CW) study of silicone hydrogel (SiH) and gas permeable (GP) contact lenses. Subjects were examined by optometrists throughout contact lens adaptation and CW periods. Statistical methods included the Kaplan-Meier nonparametric estimator of the survival function and the Cox proportional hazards model for estimating the relative effects of covariates. Of the 204 subjects, 72 (35%) developed CEF. In 64% of cases, CEFs were observed bilaterally. The majority of cases (90.3%) presented with CEF in the superior conjunctiva. Mean survival time free of CEF was longer for GP lenses (94.3 days) than for SiH lenses (76.5 days), and the probability of developing CEF was significantly greater for SiH lenses (p = 0.002). Although there was some evidence that women and non-Asians remain free of CEF longer, the effects of age, gender, and ethnicity were not statistically significant. There was a significantly increased risk of CEF in subjects wearing SiH lenses, compared with GP lenses. Subjects wearing SiH lenses remained free of CEF for a shorter time on average. Further study is needed to determine whether the increased incidence of CEF in CW with SiH lenses poses an increased risk of adverse ocular response or infection.

  1. Selection of optical model of stereophotography experiment for determination the cloud base height as a problem of testing of statistical hypotheses

    NASA Astrophysics Data System (ADS)

    Chulichkov, Alexey I.; Nikitin, Stanislav V.; Emilenko, Alexander S.; Medvedev, Andrey P.; Postylyakov, Oleg V.

    2017-10-01

    Earlier, we developed a method for estimating the height and speed of clouds from cloud images obtained by a pair of digital cameras. The shift of a fragment of the cloud in the right frame relative to its position in the left frame is used to estimate the height of the cloud and its velocity. This shift is estimated by the method of the morphological analysis of images. However, this method requires that the axes of the cameras are parallel. Instead of real adjustment of the axes, we use virtual camera adjustment, namely, a transformation of a real frame, the result of which could be obtained if all the axes were perfectly adjusted. For such adjustment, images of stars as infinitely distant objects were used: on perfectly aligned cameras, images on both the right and left frames should be identical. In this paper, we investigate in more detail possible mathematical models of cloud image deformations caused by the misalignment of the axes of two cameras, as well as their lens aberration. The simplest model follows the paraxial approximation of lens (without lens aberrations) and reduces to an affine transformation of the coordinates of one of the frames. The other two models take into account the lens distortion of the 3rd and 3rd and 5th orders respectively. It is shown that the models differ significantly when converting coordinates near the edges of the frame. Strict statistical criteria allow choosing the most reliable model, which is as much as possible consistent with the measurement data. Further, each of these three models was used to determine parameters of the image deformations. These parameters are used to provide cloud images to mean what they would have when measured using an ideal setup, and then the distance to cloud is calculated. The results were compared with data of a laser range finder.

  2. The fabrication of a multi-spectral lens array and its application in assisting color blindness

    NASA Astrophysics Data System (ADS)

    Di, Si; Jin, Jian; Tang, Guanrong; Chen, Xianshuai; Du, Ruxu

    2016-01-01

    This article presents a compact multi-spectral lens array and describes its application in assisting color-blindness. The lens array consists of 9 microlens, and each microlens is coated with a different color filter. Thus, it can capture different light bands, including red, orange, yellow, green, cyan, blue, violet, near-infrared, and the entire visible band. First, the fabrication process is described in detail. Second, an imaging system is setup and a color blindness testing card is selected as the sample. By the system, the vision results of normal people and color blindness can be captured simultaneously. Based on the imaging results, it is possible to be used for helping color-blindness to recover normal vision.

  3. An investigation of microstructural characteristics of contact-lens polymers

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Eftekhari, Abe; Upchurch, Billy T.; Burns, Karen S.

    1990-01-01

    The free volume and gas permeability in several contact lens specimens were measured as part of a Space Commercialization Program. Free volume was measured using positron lifetime spectroscopy, while permeability for O2, N2, CO2 gases was measured using mass spectrometry and polarography. Permeability for all gases increases with the mean free volume cell size in the test samples. As might be expected, the specimens with the highest free volume fraction also exhibit the lowest Rockwell Hardness Number. An interesting corollary is the finding that the presence of fluorine atoms in the lens chemical structure inhibits filling up of their free volume cells. This is expected to allow the lenses to breathe freely while in actual use.

  4. Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses.

    PubMed

    Grabowicz, W; Domienik-Andrzejewska, J; Masiarek, K; Górnik, T; Grycewicz, T; Brodecki, M; Lubiński, A

    2017-09-01

    The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician's and patient's doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians' and nurses' eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/μGym 2 , 2.31e-4 ± 1.21e-4 mSv/μGym 2 , and 2.60e-5 ± 1.57e-5 mSv/μGym 2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/μGym 2 , 1.70e-4 ± 1.01e-4 mSv/μGym 2 , and 1.86e-5 ± 1.13e-5 mSv/μGym 2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician's work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.

  5. Integration of a high-NA light microscope in a scanning electron microscope.

    PubMed

    Zonnevylle, A C; Van Tol, R F C; Liv, N; Narvaez, A C; Effting, A P J; Kruit, P; Hoogenboom, J P

    2013-10-01

    We present an integrated light-electron microscope in which an inverted high-NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high-resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub-10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum-compatible immersion oil. For a 40-nm-diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  6. Solar powered desalination system using Fresnel lens

    NASA Astrophysics Data System (ADS)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  7. Atomic force microscopy and Langmuir-Blodgett monolayer technique to assess contact lens deposits and human meibum extracts.

    PubMed

    Hagedorn, Sarah; Drolle, Elizabeth; Lorentz, Holly; Srinivasan, Sruthi; Leonenko, Zoya; Jones, Lyndon

    2015-01-01

    The purpose of this exploratory study was to investigate the differences in meibomian gland secretions, contact lens (CL) lipid extracts, and CL surface topography between participants with and without meibomian gland dysfunction (MGD). Meibum study: Meibum was collected from all participants and studied via Langmuir-Blodgett (LB) deposition with subsequent Atomic Force Microscopy (AFM) visualization and surface roughness analysis. CL Study: Participants with and without MGD wore both etafilcon A and balafilcon A CLs in two different phases. CL lipid deposits were extracted and analyzed using pressure-area isotherms with the LB trough and CL surface topographies and roughness values were visualized using AFM. Meibum study: Non-MGD participant meibum samples showed larger, circular aggregates with lower surface roughness, whereas meibum samples from participants with MGD showed more lipid aggregates, greater size variability and higher surface roughness. CL Study: Worn CLs from participants with MGD had a few large tear film deposits with lower surface roughness, whereas non-MGD participant-worn lenses had many small lens deposits with higher surface roughness. Balafilcon A pore depths were shallower in MGD participant worn lenses when compared to non-MGD participant lenses. Isotherms of CL lipid extracts from MGD and non-MGD participants showed a seamless rise in surface pressure as area decreased; however, extracts from the two different lens materials produced different isotherms. MGD and non-MGD participant-worn CL deposition were found to differ in type, amount, and pattern of lens deposits. Lipids from MGD participants deposited irregularly whereas lipids from non-MGD participants showed more uniformity. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  8. The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens.

    PubMed

    Park, Suhyun; Yoon, Heechul; Larin, Kirill V; Emelianov, Stanislav Y; Aglyamov, Salavat R

    2016-12-20

    Intraocular pressure (IOP) is believed to influence the mechanical properties of ocular tissues including cornea and sclera. The elastic properties of the crystalline lens have been mainly investigated with regard to presbyopia, the age-related loss of accommodation power of the eye. However, the relationship between the elastic properties of the lens and IOP remains to be established. The objective of this study is to measure the elastic wave velocity, which represents the mechanical properties of tissue, in the crystalline lens ex vivo in response to changes in IOP. The elastic wave velocities in the cornea and lens from seven enucleated bovine globe samples were estimated using ultrasound shear wave elasticity imaging. To generate and then image the elastic wave propagation, an ultrasound imaging system was used to transmit a 600 µs pushing pulse at 4.5 MHz center frequency and to acquire ultrasound tracking frames at 6 kHz frame rate. The pushing beams were separately applied to the cornea and lens. IOP in the eyeballs was varied from 5 to 50 mmHg. The results indicate that while the elastic wave velocity in the cornea increased from 0.96  ±  0.30 m s -1 to 6.27  ±  0.75 m s -1 as IOP was elevated from 5 to 50 mmHg, there were insignificant changes in the elastic wave velocity in the crystalline lens with the minimum and the maximum speeds of 1.44  ±  0.27 m s -1 and 2.03  ±  0.46 m s -1 , respectively. This study shows that ultrasound shear wave elasticity imaging can be used to assess the biomechanical properties of the crystalline lens noninvasively. Also, it was observed that the dependency of the crystalline lens stiffness on the IOP was significantly lower in comparison with that of cornea.

  9. Contribution of the gradient refractive index and shape to the crystalline lens spherical aberration and astigmatism.

    PubMed

    Birkenfeld, Judith; de Castro, Alberto; Ortiz, Sergio; Pascual, Daniel; Marcos, Susana

    2013-06-28

    The optical properties of the crystalline lens are determined by its shape and refractive index distribution. However, to date, those properties have not been measured together in the same lens, and therefore their relative contributions to optical aberrations are not fully understood. The shape, the optical path difference, and the focal length of ten porcine lenses (age around 6 months) were measured in vitro using Optical Coherence Tomography and laser ray tracing. The 3D Gradient Refractive Index distribution (GRIN) was reconstructed by means of an optimization method based on genetic algorithms. The optimization method searched for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens in 18 different meridians. Spherical aberration and astigmatism of the lenses were estimated using computational ray tracing, with the reconstructed GRIN lens and an equivalent homogeneous refractive index. For all lenses the posterior radius of curvature was systematically steeper than the anterior one, and the conic constant of both the anterior and posterior positive surfaces was positive. In average, the measured focal length increased with increasing pupil diameter, consistent with a crystalline lens negative spherical aberration. The refractive index of nucleus and surface was reconstructed to an average value of 1.427 and 1.364, respectively, for 633 nm. The results of the GRIN reconstruction showed a wide distribution of the index in all lens samples. The GRIN shifted spherical aberration towards negative values when compared to a homogeneous index. A negative spherical aberration with GRIN was found in 8 of the 10 lenses. The presence of GRIN also produced a decrease in the total amount of lens astigmatism in most lenses, while the axis of astigmatism was only little influenced by the presence of GRIN. To our knowledge, this study is the first systematic experimental study of the relative contribution of geometry and GRIN to the aberrations in a mammal lens. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. R and D progress on second-generation crystals for Laue lens applications

    NASA Astrophysics Data System (ADS)

    Barrière, N.; von Ballmoos, P.; Bastie, P.; Courtois, P.; Abrosimov, N. V.; Andersen, K.; Buslaps, T.; Camus, T.; Halloin, H.; Jentschel, M.; Knödlseder, J.; Roudil, G.; Serre, D.; Skinner, G.

    2007-09-01

    The concept of a gamma-ray telescope based on a Laue lens offers the possibility to increase the sensitivity by more than an order of magnitude with respect to existing instruments. Laue lenses have been developed by our collaboration for several years : the main achievement of this R&D program was the CLAIRE lens prototype, which has successfully demonstrated the feasibility of the concept in astrophysical conditions. Since then, the endeavour has been oriented towards the development of efficient diffracting elements (crystal slabs) in order to increase both the effective area and the width of the energy bandpass focused, the aim being to step from a technological Laue lens to a scientifically exploitable lens. The latest mission concept featuring a gamma-ray lens is the European Gamma- Ray Imager (GRI) which intends to make use of the Laue lens to cover energies from 200 keV to 1300 keV. Investigations of two promising materials, low mosaicity copper and gradient concentration silicongermanium are presented in this paper. The measurements have been performed during three runs: 6 + 4 days at the European Synchrotron Radiation Facility (Grenoble, France), on beamline ID15A, using a 500 keV monochromatic beam, and 14 days on the GAMS 4 instrument of the Institute Laue Langevin (Grenoble, France) featuring a highly monochromatic beam of 517 keV. Despite it was not perfectly homogeneous, the presented copper crystal has exhibited peak reflectivity of 25 % in accordance with theoretical predictions, and a mosaicity around 26 arcsec, the ideal range for the realization of a Laue lens such as GRI. Silicon-germanium featuring a constant gradient have been measured for the very first time at 500 keV. Two samples showed a quite homogeneous reflectivity reaching 26%, which is far from the 48 % already observed in experimental crystals but a very encouraging beginning. The measured results have been used to estimate the performance of the GRI Laue lens design.

  11. Drug resistance profile and biofilm forming potential of Pseudomonas aeruginosa isolated from contact lenses in Karachi-Pakistan

    PubMed Central

    2013-01-01

    Background The contaminated contact lens provides Pseudomonas aeruginosa an ideal site for attachment and biofilm production. Continuous contact of the eye to the biofilm-infested lens can lead to serious ocular diseases, such as keratitis (corneal ulcers). The biofilms also prevent effective penetration of the antibiotics, which increase the chances of antibiotic resistance. Methods For this study, 22 Pseudomonas aeruginosa isolates were obtained from 36 contact lenses and 14 contact lens protective fluid samples. These isolates were tested against eight commonly used antibiotics using Kirby-Bauer disk diffusion method. The biofilm forming potential of these isolates was also evaluated using various qualitative and quantitative techniques. Finally, a relationship between biofilm formation and antibiotic resistance was also examined. Results The isolates of Pseudomonas aeruginosa tested were found resistant to most of the antibiotics tested. Qualitative and quantitative biofilm analysis revealed that most of the isolates exhibited strong biofilm production. The biofilm production was significantly higher in isolates that were multi-drug resistant (p < 0.0001). Conclusion Our study indicates that multi-drug resistant, biofilm forming Pseudomonas aeruginosa isolates are mainly involved in contact lens associated infections. This appears to be the first report from Pakistan, which analyzes both antibiotic resistance profile and biofilm forming potential of Pseudomonas aeruginosa isolates from contact lens of the patients with contact lens associated infections. PMID:24134792

  12. Dynamics of active emmetropisation in young chicks – influence of sign and magnitude of imposed defocus

    PubMed Central

    Hammond, David S; Wallman, Josh; Wildsoet, Christine F

    2014-01-01

    Purpose Young eyes compensate for the defocus imposed by spectacle lenses by changing their rate of elongation and their choroidal thickness, bringing their refractive status back to the pre-lens condition. We asked whether the initial rate of change either in the ocular components or in refraction is a function of the power of the lenses worn, a result that would be consistent with the existence of a proportional controller mechanism. Methods Two separate studies were conducted; both tracked changes in refractive errors and ocular dimensions. Study A: To study the effects of lens power and sign, young chicks were tracked for 4 days after they were fitted with positive (+5, +10 or +15 D) or negative (−5, −10, −15 D) lenses over one eye. In another experiment, biometric changes to plano, +1, +2 and +3 D lenses were tracked over a 24 h treatment period. Study B: Normal emmetropisation was tracked from hatching to 6 days of age and then a defocusing lens, either +6 D or −7 D, was fitted over one eye and additional biometric data collected after 48 h. Results In study A, animals treated with positive lenses (+5, +10 or +15 D) showed statistical similar initial choroid responses, with a mean thickening 24 μm h−1 over the first 5 h. Likewise, with the low power positive lenses, a statistically similar magnitude of choroidal thickening was observed across groups (+1 D: 46.0 ± 7.8 μm h−1; +2 D: 53.5 ± 9.9 μm h−1; +3 D 53.3 ± 24.1 μm h−1) in the first hour of lens wear compared to that of a plano control group. These similar rates of change in choroidal thickness indicate that the signalling response is binary in nature and not influenced by the magnitude of the myopic defocus. Treatments with −5, −10 and −15 D lenses induced statistically similar amounts of choroidal thinning, averaging −70 ± 15 μm after 5h and −96 ± 45 μm after 24 h. Similar rates in inner axial length changes were also seen with these lens treatments until compensation was reached, once again indicating that the signalling response is not influenced by the magnitude of hyperopic defocus. In study B, after 48 h of +6 D lens treatment, the average refractive error and choroidal changes were found to be larger in magnitude than expected if perfect compensation had taken place, with a + 2.4 D overshoot in refractive compensation. Conclusion Taken together, our results with both weak and higher power positive lenses suggest that eye growth is guided more by the sign than by the magnitude of the defocus, and our results for higher power negative lenses support a similar conclusion. These behaviour patterns and the overshoot seen in Study B are more consistent with the behaviour of a bang-bang controller than a proportional controller. PMID:23662956

  13. Is There a Cosmological Constant?

    NASA Technical Reports Server (NTRS)

    Kochanek, Christopher; Oliversen, Ronald J. (Technical Monitor)

    2002-01-01

    The grant contributed to the publication of 18 refereed papers and 5 conference proceedings. The primary uses of the funding have been for page charges, travel for invited talks related to the grant research, and the support of a graduate student, Charles Keeton. The refereed papers address four of the primary goals of the proposal: (1) the statistics of radio lenses as a probe of the cosmological model (#1), (2) the role of spiral galaxies as lenses (#3), (3) the effects of dust on statistics of lenses (#7, #8), and (4) the role of groups and clusters as lenses (#2, #6, #10, #13, #15, #16). Four papers (#4, #5, #11, #12) address general issues of lens models, calibrations, and the relationship between lens galaxies and nearby galaxies. One considered cosmological effects in lensing X-ray sources (#9), and two addressed issues related to the overall power spectrum and theories of gravity (#17, #18). Our theoretical studies combined with the explosion in the number of lenses and the quality of the data obtained for them is greatly increasing our ability to characterize and understand the lens population. We can now firmly conclude both from our study of the statistics of radio lenses and our survey of extinctions in individual lenses that the statistics of optically selected quasars were significantly affected by extinction. However, the limits on the cosmological constant remain at lambda < 0.65 at a 2-sigma confidence level, which is in mild conflict with the results of the Type la supernova surveys. We continue to find that neither spiral galaxies nor groups and clusters contribute significantly to the production of gravitational lenses. The lack of group and cluster lenses is strong evidence for the role of baryonic cooling in increasing the efficiency of galaxies as lenses compared to groups and clusters of higher mass but lower central density. Unfortunately for the ultimate objective of the proposal, improved constraints on the cosmological constant, the next large survey for gravitational lenses did not release its results during the term of the proposal. The research supported the career development. of six graduate students (polar, Fletcher, Herold, Keeton, Deng and Rusin) and two post-docs (Labor and Munoz).

  14. Lens-free imaging of magnetic particles in DNA assays.

    PubMed

    Colle, Frederik; Vercruysse, Dries; Peeters, Sara; Liu, Chengxun; Stakenborg, Tim; Lagae, Liesbet; Del-Favero, Jurgen

    2013-11-07

    We present a novel opto-magnetic system for the fast and sensitive detection of nucleic acids. The system is based on a lens-free imaging approach resulting in a compact and cheap optical readout of surface hybridized DNA fragments. In our system magnetic particles are attracted towards the detection surface thereby completing the labeling step in less than 1 min. An optimized surface functionalization combined with magnetic manipulation was used to remove all nonspecifically bound magnetic particles from the detection surface. A lens-free image of the specifically bound magnetic particles on the detection surface was recorded by a CMOS imager. This recorded interference pattern was reconstructed in software, to represent the particle image at the focal distance, using little computational power. As a result we were able to detect DNA concentrations down to 10 pM with single particle sensitivity. The possibility of integrated sample preparation by manipulation of magnetic particles, combined with the cheap and highly compact lens-free detection makes our system an ideal candidate for point-of-care diagnostic applications.

  15. Quantifying the line-of-sight mass distributions for time-delay lenses with stellar masses

    NASA Astrophysics Data System (ADS)

    Rusu, Cristian; Fassnacht, Chris; Treu, Tommaso; Suyu, Sherry; Auger, Matt; Koopmans, Leon; Marshall, Phil; Wong, Kenneth; Collett, Thomas; Agnello, Adriano; Blandford, Roger; Courbin, Frederic; Hilbert, Stefan; Meylan, Georges; Sluse, Dominique

    2014-12-01

    Measuring cosmological parameters with a realistic account of systematic uncertainties is currently one of the principal challenges of physical cosmology. Building on our recent successes with two gravitationally lensed systems, we have started a program to achieve accurate cosmographic measurements from five gravitationally lensed quasars. We aim at measuring H_0 with an accuracy better than 4%, comparable to but independent from measurements by current BAO, SN or Cepheid programs. The largest current contributor to the error budget in our sample is uncertainty about the line-of-sight mass distribution and environment of the lens systems. In this proposal, we request wide-field u-band imaging of the only lens in our sample without already available Spitzer/IRCA observations, B1608+656. The proposed observations are critical for reducing these uncertainties by providing accurate redshifts and in particular stellar masses for galaxies in the light cones of the target lens system. This will establish lensing as a powerful and independent tool for determining cosmography, in preparation for the hundreds of time-delay lenses that will be discovered by future surveys.

  16. Discrimination of geographical origin of lentils (Lens culinaris Medik.) using isotope ratio mass spectrometry combined with chemometrics.

    PubMed

    Longobardi, F; Casiello, G; Cortese, M; Perini, M; Camin, F; Catucci, L; Agostiano, A

    2015-12-01

    The aim of this study was to predict the geographic origin of lentils by using isotope ratio mass spectrometry (IRMS) in combination with chemometrics. Lentil samples from two origins, i.e. Italy and Canada, were analysed obtaining the stable isotope ratios of δ(13)C, δ(15)N, δ(2)H, δ(18)O, and δ(34)S. A comparison between median values (U-test) highlighted statistically significant differences (p<0.05) for all isotopic parameters between the lentils produced in these two different geographic areas, except for δ(15)N. Applying principal component analysis, grouping of samples was observed on the basis of origin but with overlapping zones; consequently, two supervised discriminant techniques, i.e. partial least squares discriminant analysis and k-nearest neighbours algorithm were used. Both models showed good performances with external prediction abilities of about 93% demonstrating the suitability of the methods developed. Subsequently, isotopic determinations were also performed on the protein and starch fractions and the relevant results are reported. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Quantitative molecular characterization of bovine vitreous and lens with non-invasive dynamic light scattering

    NASA Technical Reports Server (NTRS)

    Ansari, R. R.; Suh, K. I.; Dunker, S.; Kitaya, N.; Sebag, J.

    2001-01-01

    The non-invasive technique of dynamic light scattering (DLS) was used to quantitatively characterize vitreous and lens structure on a molecular level by measuring the sizes of the predominant particles and mapping the three-dimensional topographic distribution of these structural macromolecules in three spatial dimensions. The results of DLS measurements in five fresh adult bovine eyes were compared to DLS measurements in model solutions of hyaluronan (HA) and collagen (Coll). In the bovine eyes DLS measurements were obtained from excised samples of gel and liquid vitreous and compared to the model solutions. Measurements in whole vitreous were obtained at multiple points posterior to the lens to generate a three-dimensional 'map' of molecular structure. The macromolecule distribution in bovine lens was similarly characterized.In each bovine vitreous (Bo Vit) specimen, DLS predominantly detected two distinct particles, which differed in diffusion properties and hence size. Comparisons with model vitreous solutions demonstrated that these most likely corresponded to the Coll and HA components of vitreous. Three-dimensional mapping of Bo Vit found heterogeneity throughout the vitreous body, with different particle size distributions for Coll and HA at different loci. In contrast, the three-dimensional distribution of lens macromolecules was more homogeneous. Thus, the non-invasive DLS technique can quantitate the average sizes of vitreous and lens macromolecules and map their three-dimensional distribution. This method to assess quantitatively the macromolecular structure of vitreous and lens should be useful for clinical as well as experimental applications in health and disease. Copyright 2001 Academic Press.

  18. Through the Lens of Home-Educated Children: Engagement in Education

    ERIC Educational Resources Information Center

    Jones, Tara

    2013-01-01

    Engagement and participation are important for successful outcomes in education, yet disaffection in the UK, according to some exclusion and absence statistics, shows a growing trend. The purpose of this research was to develop a starting point for a theory of children's engagement in education using grounded theory method. Evidence from…

  19. Estimation of positive semidefinite correlation matrices by using convex quadratic semidefinite programming.

    PubMed

    Fushiki, Tadayoshi

    2009-07-01

    The correlation matrix is a fundamental statistic that is used in many fields. For example, GroupLens, a collaborative filtering system, uses the correlation between users for predictive purposes. Since the correlation is a natural similarity measure between users, the correlation matrix may be used in the Gram matrix in kernel methods. However, the estimated correlation matrix sometimes has a serious defect: although the correlation matrix is originally positive semidefinite, the estimated one may not be positive semidefinite when not all ratings are observed. To obtain a positive semidefinite correlation matrix, the nearest correlation matrix problem has recently been studied in the fields of numerical analysis and optimization. However, statistical properties are not explicitly used in such studies. To obtain a positive semidefinite correlation matrix, we assume the approximate model. By using the model, an estimate is obtained as the optimal point of an optimization problem formulated with information on the variances of the estimated correlation coefficients. The problem is solved by a convex quadratic semidefinite program. A penalized likelihood approach is also examined. The MovieLens data set is used to test our approach.

  20. Noninvasive Quantification of Retinal Microglia Using Widefield Autofluorescence Imaging.

    PubMed

    Kokona, Despina; Schneider, Nadia; Giannakaki-Zimmermann, Helena; Jovanovic, Joel; Ebneter, Andreas; Zinkernagel, Martin

    2017-04-01

    To validate widefield autofluorescence (AF) in vivo imaging of the retina in mice expressing green fluorescent protein (gfp) in microglia, and to monitor retinal microglia reconstitution in vivo after lethal irradiation and bone marrow transplantation. Transgenic Cx3cr1gfp/gfp and wildtype Balb/c mice were used in this study. A confocal scanning laser ophthalmoscope was used for AF imaging with a 55° and a widefield 102° lens. Intrasession reproducibility was assessed for each lens. To investigate reconstitution in vivo, bone marrow from Cx3cr1gfp/gfp mice was used to rescue lethally irradiated wildtype mice. Data were compared to confocal microscopy of retinal flat mounts. Both the 55° and the 102° lens produced high resolution images of retinal microglia with similar microglia density. However, compared to the 55° lens, the widefield 102° lens captured approximately 3.6 times more microglia cells (1515 ± 123 cells versus 445 ± 76 cells [mean ± SD], for 102° and 55°, respectively, P < 0.001). No statistical difference in the number of gfp positive cells within corresponding areas was observed within the same imaging session. Imaging of microglia reconstitution showed a similar time course compared to flat mount preparations with an excellent correlation between microglia cell numbers in AF and gfp-stained flat mounts (R = 0.92, P < 0.0001). Widefield AF imaging of mice with gfp expressing microglia can be used to quantify retinal microglia. In vivo microglia counts corresponded very well with ex vivo counts on retinal flat mounts. As such, AF imaging can largely replace ex vivo quantification.

  1. Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens

    PubMed Central

    Packer, Mark

    2016-01-01

    The purpose of this review is to summarize relevant data from publications appearing in the peer-reviewed scientific literature over the past decade since US Food and Drug Administration approval of the implantable collamer lens (ICL), and, in particular, to review studies relating to sizing methodology, safety, and effectiveness, as well as more recent studies reporting clinical outcomes of the V4c Visian ICL with KS Aquaport, VICMO. A literature search was conducted using two databases, PubMed.gov and Science.gov, to identify all articles published after 2005 related to the Visian ICL (STAAR Surgical, Inc.). Articles were examined for their relevance to sizing methodology, clinical safety, and effectiveness, and the references cited in each article were also searched for additional relevant publications. The literature review revealed that all currently reported methods of determining the best-fit size of the ICL achieve similarly satisfactory results in terms of vault, the safe distance between the crystalline lens and the ICL. Specifically, meta-analysis demonstrated that sulcus-to-sulcus and white-to-white measurement-based sizing methods do not result in clinically meaningful nor statistically significant differences in vault (two-sample two-sided t-test using pooled mean and standard deviations; t (2,594)=1.33; P=0.18). The reported rates of complications related to vault are very low, except in two case series where additional risk factors such as higher levels of myopia and older age impacted the incidence of cataract. On the basis of preclinical studies and initial clinical reports, with up to 5 years of follow-up, the new VICMO central port design holds promise for further reduction of complications. Given its safety record and the significant improvement in vision and quality of life that the ICL makes possible, the benefits of ICL implantation outweigh the risks. PMID:27354760

  2. Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

    PubMed

    Packer, Mark

    2016-01-01

    The purpose of this review is to summarize relevant data from publications appearing in the peer-reviewed scientific literature over the past decade since US Food and Drug Administration approval of the implantable collamer lens (ICL), and, in particular, to review studies relating to sizing methodology, safety, and effectiveness, as well as more recent studies reporting clinical outcomes of the V4c Visian ICL with KS Aquaport, VICMO. A literature search was conducted using two databases, PubMed.gov and Science.gov, to identify all articles published after 2005 related to the Visian ICL (STAAR Surgical, Inc.). Articles were examined for their relevance to sizing methodology, clinical safety, and effectiveness, and the references cited in each article were also searched for additional relevant publications. The literature review revealed that all currently reported methods of determining the best-fit size of the ICL achieve similarly satisfactory results in terms of vault, the safe distance between the crystalline lens and the ICL. Specifically, meta-analysis demonstrated that sulcus-to-sulcus and white-to-white measurement-based sizing methods do not result in clinically meaningful nor statistically significant differences in vault (two-sample two-sided t-test using pooled mean and standard deviations; t (2,594)=1.33; P=0.18). The reported rates of complications related to vault are very low, except in two case series where additional risk factors such as higher levels of myopia and older age impacted the incidence of cataract. On the basis of preclinical studies and initial clinical reports, with up to 5 years of follow-up, the new VICMO central port design holds promise for further reduction of complications. Given its safety record and the significant improvement in vision and quality of life that the ICL makes possible, the benefits of ICL implantation outweigh the risks.

  3. Dynamic Optically Multiplexed Imaging

    DTIC Science & Technology

    2015-07-29

    Direction LENS.ZMX Configuration 1 of 1 3D Layout 10/21/2014 Scale: 1.000020.00 Millimeters X Y Z Parent Lens (a) (b) 0 20 40 60 80 100 0 20 40 60 80 100...V. Shah, and T. Shih “Design Architectures for Optically Multiplexed Imaging,” in submission 9 R. Gupta, P . Indyk, E. Price, and Y . Rachlin...the number of multiplexed images. As a result, measurements from a sufficiently fast sampling sensor can be processed to yield a low distortion image

  4. The effect of varying glucose levels on the ex vivo crystalline lens: implications for hyperglycaemia-induced refractive changes.

    PubMed

    Mehta, Vikram V; Hull, Christopher C; Lawrenson, John G

    2015-01-01

    Refractive changes in diabetic eyes have long been reported but with equivocal results. The lens has been a more recent focus as the source of any change but it is possible that multiple sources of variation have made it difficult to demonstrate a systematic change clinically. The aim of this study was therefore to use a bovine lens model to investigate the optical changes in hyperglycaemia and when lenses are returned to normal glucose levels as would occur following commencement of treatment. Bovine eyes were obtained and their lenses excised under sterile conditions before placing them in culture medium within an incubator using standard tissue culture techniques. In the first experiment, lenses were transferred into culture medium containing 5 mm (n = 12), 15 mm (n = 12) and 30 mm (n = 12) glucose. Measurements were made of the change in back vertex focusing distance with equatorial lens diameter using the ScanTox(™) measurement system. From these measurements, the back vertex focal length and primary longitudinal spherical aberration were derived. In a second experiment, lenses maintained at 30 mm glucose (n = 7) were stepped down to 5 mm glucose to simulate starting diabetic therapy and measured in the same way. Changes over time were assessed with a linear regression model. A trend towards myopia was observed with increasing hyperglycaemia, this was not statistically significant. When lenses were stepped-down from hyperglycaemia to normal physiological levels of glucose, a hyperopic shift was observed in line with published clinical studies that again failed to reach statistical significance. High variability in the measurement on longitudinal spherical aberration prevented any significant trends being measured. Our results suggest that there are no consistent crystalline lens-induced refractive changes following exposure to hyperglycaemia for time-periods up to 5 days used in the current study. It is possible that bovine lenses are able to offset the raised osmotic pressure from high glucose levels in the short-term by a process of osmoregulation and that repeated osmotic stress or longer term exposure may be required to induce the changes in refraction that are seen clinically. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  5. Quantitative X-ray fluorescence computed tomography for low-Z samples using an iterative absorption correction algorithm

    NASA Astrophysics Data System (ADS)

    Huang, Rong; Limburg, Karin; Rohtla, Mehis

    2017-05-01

    X-ray fluorescence computed tomography is often used to measure trace element distributions within low-Z samples, using algorithms capable of X-ray absorption correction when sample self-absorption is not negligible. Its reconstruction is more complicated compared to transmission tomography, and therefore not widely used. We describe in this paper a very practical iterative method that uses widely available transmission tomography reconstruction software for fluorescence tomography. With this method, sample self-absorption can be corrected not only for the absorption within the measured layer but also for the absorption by material beyond that layer. By combining tomography with analysis for scanning X-ray fluorescence microscopy, absolute concentrations of trace elements can be obtained. By using widely shared software, we not only minimized the coding, took advantage of computing efficiency of fast Fourier transform in transmission tomography software, but also thereby accessed well-developed data processing tools coming with well-known and reliable software packages. The convergence of the iterations was also carefully studied for fluorescence of different attenuation lengths. As an example, fish eye lenses could provide valuable information about fish life-history and endured environmental conditions. Given the lens's spherical shape and sometimes the short distance from sample to detector for detecting low concentration trace elements, its tomography data are affected by absorption related to material beyond the measured layer but can be reconstructed well with our method. Fish eye lens tomography results are compared with sliced lens 2D fluorescence mapping with good agreement, and with tomography providing better spatial resolution.

  6. Lensfree diffractive tomography for the imaging of 3D cell cultures

    NASA Astrophysics Data System (ADS)

    Berdeu, Anthony; Momey, Fabien; Dinten, Jean-Marc; Gidrol, Xavier; Picollet-D'hahan, Nathalie; Allier, Cédric

    2017-02-01

    New microscopes are needed to help reaching the full potential of 3D organoid culture studies by gathering large quantitative and systematic data over extended periods of time while preserving the integrity of the living sample. In order to reconstruct large volumes while preserving the ability to catch every single cell, we propose new imaging platforms based on lens-free microscopy, a technic which is addressing these needs in the context of 2D cell culture, providing label-free and non-phototoxic acquisition of large datasets. We built lens-free diffractive tomography setups performing multi-angle acquisitions of 3D organoid cultures embedded in Matrigel and developed dedicated 3D holographic reconstruction algorithms based on the Fourier diffraction theorem. Nonetheless, holographic setups do not record the phase of the incident wave front and the biological samples in Petri dish strongly limit the angular coverage. These limitations introduce numerous artefacts in the sample reconstruction. We developed several methods to overcome them, such as multi-wavelength imaging or iterative phase retrieval. The most promising technic currently developed is based on a regularised inverse problem approach directly applied on the 3D volume to reconstruct. 3D reconstructions were performed on several complex samples such as 3D networks or spheroids embedded in capsules with large reconstructed volumes up to 25 mm3 while still being able to identify single cells. To our knowledge, this is the first time that such an inverse problem approach is implemented in the context of lens-free diffractive tomography enabling to reconstruct large fully 3D volumes of unstained biological samples.

  7. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.« less

  8. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rehani, M.

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.« less

  9. Touch And Go Camera System (TAGCAMS) for the OSIRIS-REx Asteroid Sample Return Mission

    NASA Astrophysics Data System (ADS)

    Bos, B. J.; Ravine, M. A.; Caplinger, M.; Schaffner, J. A.; Ladewig, J. V.; Olds, R. D.; Norman, C. D.; Huish, D.; Hughes, M.; Anderson, S. K.; Lorenz, D. A.; May, A.; Jackman, C. D.; Nelson, D.; Moreau, M.; Kubitschek, D.; Getzandanner, K.; Gordon, K. E.; Eberhardt, A.; Lauretta, D. S.

    2018-02-01

    NASA's OSIRIS-REx asteroid sample return mission spacecraft includes the Touch And Go Camera System (TAGCAMS) three camera-head instrument. The purpose of TAGCAMS is to provide imagery during the mission to facilitate navigation to the target asteroid, confirm acquisition of the asteroid sample, and document asteroid sample stowage. The cameras were designed and constructed by Malin Space Science Systems (MSSS) based on requirements developed by Lockheed Martin and NASA. All three of the cameras are mounted to the spacecraft nadir deck and provide images in the visible part of the spectrum, 400-700 nm. Two of the TAGCAMS cameras, NavCam 1 and NavCam 2, serve as fully redundant navigation cameras to support optical navigation and natural feature tracking. Their boresights are aligned in the nadir direction with small angular offsets for operational convenience. The third TAGCAMS camera, StowCam, provides imagery to assist with and confirm proper stowage of the asteroid sample. Its boresight is pointed at the OSIRIS-REx sample return capsule located on the spacecraft deck. All three cameras have at their heart a 2592 × 1944 pixel complementary metal oxide semiconductor (CMOS) detector array that provides up to 12-bit pixel depth. All cameras also share the same lens design and a camera field of view of roughly 44° × 32° with a pixel scale of 0.28 mrad/pixel. The StowCam lens is focused to image features on the spacecraft deck, while both NavCam lens focus positions are optimized for imaging at infinity. A brief description of the TAGCAMS instrument and how it is used to support critical OSIRIS-REx operations is provided.

  10. Intacs for keratoconus and post-LASIK ectasia: mechanical versus femtosecond laser-assisted channel creation.

    PubMed

    Carrasquillo, Karen G; Rand, Janet; Talamo, Jonathan H

    2007-09-01

    To evaluate the efficacy of intracorneal ring segments to treat keratoconus and post-laser in situ keratomileusis (LASIK) keratectasia implanted by using either mechanical dissection or a femtosecond laser. Thirty-three eyes of 29 patients had intracorneal ring segments implanted by using mechanical dissection (17 eyes) or a femtosecond laser (16 eyes). Mean follow-up was 10.3 months. Parameters assessed before and after surgery included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refractive spherical equivalent (MRSE), refractive cylinder (RC), best contact lens-corrected visual acuity (BCLVA), and contact lens tolerance. Statistically significant changes occurred for all parameters when we analyzed all 33 eyes as 1 group. Mean UCVA LogMar values improved from 1.0 +/- 0.3 (20/200) to 0.6 +/- 0.4 (20/80) (P < 0.0005). Mean BSCVA changed from 0.3 +/- 0.2 (20/40) to 0.2 +/- 0.2 (20/30) (10%; P < 0.05), and MRSE from -9 +/- 4 to -7 +/- 4 D (P < 0.05; 20%). There was a decrease of 0.5 D or more of RC in 62% of eyes. BCLVA improved from 0.2 +/- 0.2 (20/30) to 0.1 +/- 0.1 (20/25) after surgery (P < 0.02). Contact lens tolerance improved in 81% of eyes. There was no statistically significant difference in outcomes between mechanical dissection and femtosecond laser-assisted techniques. However, although statistical power was adequate to detect changes in clinical parameters as a result of surgery, it was not sufficient to conclusively show such differences between surgical techniques. For mild to moderate cases of keratoconus and post-LASIK keratectasia, the use of a femtosecond laser for Intacs channel creation seems as effective as mechanical dissection. Future studies are warranted to further evaluate channel creation by a femtosecond laser.

  11. Time lens assisted photonic sampling extraction

    NASA Astrophysics Data System (ADS)

    Petrillo, Keith Gordon

    Telecommunication bandwidth demands have dramatically increased in recent years due to Internet based services like cloud computing and storage, large file sharing, and video streaming. Additionally, sensing systems such as wideband radar, magnetic imaging resonance systems, and complex modulation formats to handle large data transfer in telecommunications require high speed, high resolution analog-to-digital converters (ADCs) to interpret the data. Accurately processing and acquiring the information at next generation data rates from these systems has become challenging for electronic systems. The largest contributors to the electronic bottleneck are bandwidth and timing jitter which limit speed and reduce accuracy. Optical systems have shown to have at least three orders of magnitude increase in bandwidth capabilities and state of the art mode locked lasers have reduced timing jitters into thousands of attoseconds. Such features have encouraged processing signals without the use of electronics or using photonics to assist electronics. All optical signal processing has allowed the processing of telecommunication line rates up to 1.28 Tb/s and high resolution analog-to-digital converters in the 10s of gigahertz. The major drawback to these optical systems is the high cost of the components. The application of all optical processing techniques such as a time lens and chirped processing can greatly reduce bandwidth and cost requirements of optical serial to parallel converters and push photonically assisted ADCs into the 100s of gigahertz. In this dissertation, the building blocks to a high speed photonically assisted ADC are demonstrated, each providing benefits to its own respective application. A serial to parallel converter using a continuously operating time lens as an optical Fourier processor is demonstrated to fully convert a 160-Gb/s optical time division multiplexed signal to 16 10-Gb/s channels with error free operation. Using chirped processing, an optical sample and hold concept is demonstrated and analyzed as a resolution improvement to existing photonically assisted ADCs. Simulations indicate that the application of a continuously operating time lens to a photonically assisted sampling system can increase photonically sampled systems by an order of magnitude while acquiring properties similar to an optical sample and hold system.

  12. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D.

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.« less

  13. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bombmore » survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.« less

  14. Photo ion spectrometer

    DOEpatents

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A method and apparatus for extracting for quantitative analysis ions of selected atomic components of a sample. A lens system is configured to provide a slowly diminishing field region for a volume containing the selected atomic components, enabling accurate energy analysis of ions generated in the slowly diminishing field region. The lens system also enables focusing on a sample of a charged particle beam, such as an ion beam, along a path length perpendicular to the sample and extraction of the charged particles along a path length also perpendicular to the sample. Improvement of signal to noise ratio is achieved by laser excitation of ions to selected autoionization states before carrying out quantitative analysis. Accurate energy analysis of energetic charged particles is assured by using a preselected resistive thick film configuration disposed on an insulator substrate for generating predetermined electric field boundary conditions to achieve for analysis the required electric field potential. The spectrometer also is applicable in the fields of SIMS, ISS and electron spectroscopy.

  15. Photo ion spectrometer

    DOEpatents

    Gruen, D.M.; Young, C.E.; Pellin, M.J.

    1989-08-08

    A method and apparatus are described for extracting for quantitative analysis ions of selected atomic components of a sample. A lens system is configured to provide a slowly diminishing field region for a volume containing the selected atomic components, enabling accurate energy analysis of ions generated in the slowly diminishing field region. The lens system also enables focusing on a sample of a charged particle beam, such as an ion beam, along a path length perpendicular to the sample and extraction of the charged particles along a path length also perpendicular to the sample. Improvement of signal to noise ratio is achieved by laser excitation of ions to selected auto-ionization states before carrying out quantitative analysis. Accurate energy analysis of energetic charged particles is assured by using a preselected resistive thick film configuration disposed on an insulator substrate for generating predetermined electric field boundary conditions to achieve for analysis the required electric field potential. The spectrometer also is applicable in the fields of SIMS, ISS and electron spectroscopy. 8 figs.

  16. Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2014-06-01

    A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profile is imaged and collected with a 30,000 element, 0.72 mm clear aperture fiber bundle. Sampling the diffuse reflectance in two-dimensions allows for fitting of the reflected intensity profile to a well-known theoretical model, permitting the extraction of both absorption and reduced scattering coefficients of the tissue sample. Models and measurements of the endoscopic imaging system are presented in tissue phantoms and in vivo mouse colon, verifying the endoscope's capabilities to accurately measure effective attenuation coefficient and differentiate diseased from normal colon.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Auger, M. W.; Treu, T.; Marshall, P. J.

    We present the current photometric data set for the Sloan Lens ACS (SLACS) Survey, including Hubble Space Telescope (HST) photometry from Advanced Camera for Surveys, WFPC2, and NICMOS. These data have enabled the confirmation of an additional 15 grade 'A' (certain) lens systems, bringing the number of SLACS grade 'A' lenses to 85; including 13 grade 'B' (likely) systems, SLACS has identified nearly 100 lenses and lens candidates. Approximately 80% of the grade 'A' systems have elliptical morphologies while approx10% show spiral structure; the remaining lenses have lenticular morphologies. Spectroscopic redshifts for the lens and source are available for everymore » system, making SLACS the largest homogeneous data set of galaxy-scale lenses to date. We have created lens models using singular isothermal ellipsoid mass distributions for the 11 new systems that are dominated by a single mass component and where the multiple images are detected with sufficient signal to noise; these models give a high precision measurement of the mass within the Einstein radius of each lens. We have developed a novel Bayesian stellar population analysis code to determine robust stellar masses with accurate error estimates. We apply this code to deep, high-resolution HST imaging and determine stellar masses with typical statistical errors of 0.1 dex; we find that these stellar masses are unbiased compared to estimates obtained using SDSS photometry, provided that informative priors are used. The stellar masses range from 10{sup 10.5} to 10{sup 11.8} M{sub sun} and the typical stellar mass fraction within the Einstein radius is 0.4, assuming a Chabrier initial mass function. The ensemble properties of the SLACS lens galaxies, e.g., stellar masses and projected ellipticities, appear to be indistinguishable from other SDSS galaxies with similar stellar velocity dispersions. This further supports that SLACS lenses are representative of the overall population of massive early-type galaxies with M{sub *} approx> 10{sup 11} M{sub sun}, and are therefore an ideal data set to investigate the kpc-scale distribution of luminous and dark matter in galaxies out to z approx 0.5.« less

  18. Effect of povidone 2% preservative-free eyedrops on contact lens wearers with computer visual syndrome: pilot study.

    PubMed

    Guillon, Michel; Maissa, Cecile; Pouliquen, Pascale; Delval, Laurent

    2004-01-01

    To show that the use of povidone 2% preservative-free lubricating eyedrops reduces computer visual syndrome in contact lens wearers and to identify the best eyedrop instillation protocols. The test product was FILMABAK a CE-marked nonpreserved lubricant, povidone 2% delivered by the ABAK system. Three dispensing modalities were evaluated during contact lens wear and computer use: hourly instillation, symptom-related instillation, and patient's own instillation. During sustained computer use, a decrease in symptoms associated with the use of povidone 2% was statistically and clinically significant. However, the symptoms were not fully eliminated by the use of the test eyedrop. The three instillation routines achieved similar beneficial effects. No significant changes in ocular tissue response were observed, and the staining recorded after sustained computer use remained low. The use of povidone 2% preservative-free lubricating eyedrops under any of the three instillation modalities tested was also associated with a slight improvement in dynamic visual acuity. The use of povidone 2% preservative-free eyedrops was associated with an improvement in symptoms during sustained computer use. Any of the three instillation modalities decreased symptoms of ocular tiredness, dryness, and difficulty of focus; maintained an unchanged corneal surface; and improved dynamic visual acuity. Therefore, the most patient-friendly modality (patient's own instillation modality from symptom onset) could be recommended to contact lens wearers with computer visual syndrome.

  19. Age dependence of dielectric properties of bovine brain and ocular tissues in the frequency range of 400 MHz to 18 GHz

    NASA Astrophysics Data System (ADS)

    Schmid, Gernot; Überbacher, Richard

    2005-10-01

    In order to identify possible age-dependent dielectric properties of brain and eye tissues in the frequency range of 400 MHz to 18 GHz, measurements on bovine grey and white matter as well as on cornea, lens (cortical) and the vitreous body were performed using a commercially available open-ended coaxial probe and a computer-controlled vector network analyser. Freshly excised tissues of 52 animals of two age groups (42 adult animals, i.e. 16-24 month old and 10 young animals, i.e. 4-6 month old calves) were examined within 8 min (brain tissue) and 15 min (eye tissue), respectively, of the animals' death. Tissue temperatures for the measurements were 32 ± 1 °C and 25 ± 1 °C for brain and eye tissues, respectively. Statistical analysis of the measured data revealed significant differences in the dielectric properties of white matter and cortical lens tissue between the adult and the young group. In the case of white matter the mean values of conductivity and permittivity of young tissue were 15%-22% and 12%-15%, respectively, higher compared to the adult tissue in the considered frequency range. Similarly, young cortical lens tissue was 25%-76% higher in conductivity and 27%-39% higher in permittivity than adult cortical lens tissue.

  20. Ocular discomfort responses after short periods of contact lens wear.

    PubMed

    Papas, Eric; Tilia, Daniel; McNally, John; de la Jara, Percy Lazon

    2015-06-01

    To investigate if contact lens-related discomfort is a function of the time of day at which lenses are worn. This was a randomized, crossover, open-label clinical trial where subjective responses, with and without contact lenses, were assessed every 2 hours during five stages (A to E). Each stage began at the time when subjects would normally have inserted their contact lenses (T0). During stage A, no lenses were worn, whereas in stage B, lenses were worn continuously for 12 hours. In stages C to E, lenses were worn for only 4 hours. Contact lenses were inserted at T0 for stage C, but for stages D and E, lenses were not inserted until T0 + 4 and T0 + 8 hours, respectively. Mixed linear models were used for statistical analysis. In the absence of contact lenses, ocular comfort and dryness remained reasonably constant throughout the observation period. Ocular comfort and dryness decreased during 12 hours of continuous lens wear and became significantly worse from the 8-hour time onward compared with insertion (p < 0.023). There were no significant differences in terms of ocular comfort and dryness between any of the 4-hour lens wear stages (p < 0.82). During each 4-hour stage, both comfort and dryness behaved in a similar fashion (p > 0.05) to the first 4 hours of continuous contact lens wear. Comparing the scores of each of these stages with the no-lens response at the corresponding time showed no significant differences for comfort (p > 0.23) or dryness (p > 0.37). Short periods of wear can be experienced at any time of day without significant change in ocular discomfort and dryness. This suggests that subjective responses at the end of the day are determined by the length of time lenses are in contact with the eye, rather than the time of day at which lenses are worn.

  1. Protein size resolution in human eye lenses by dynamic light scattering after in vivo measurements: first analysis of a clinical validation

    NASA Astrophysics Data System (ADS)

    Dierks, Karsten; Dieckmann, Matthias; Niederstrasser, Dirk; Schwartz, R.; Wegener, Alfred R.

    1995-01-01

    Laser light source powers of our instrument LEPOSIAR are minimized so that dynamic light scattering (DLS) measurements can be conducted with lowest intensity levels on human eye lenses (3.2 mW/cm2) within measurement times of 3 to 5 seconds. We describe an extension of DLS and an eye lens characterization along the optical axis (OA), revealing the molecular size ranges together with distributions found in lens regions parallel to the OA. The microstructures of various lens regions are separated by the analyzed radius distributions reflecting the visco-elastic properties of the eye lens. Detailed analysis and applied statistical categorization of results are described. The data obtained by DLS allow for an objective interpretation of opacity occurrences on molecular size range which are related to refraction anomalies. Apart from changes in color and fluorescence properties, the refractive anomalies can be assumed as the origin of the cataract. The bimodal radius distributions are characterized as a function of patient ages varying from 9 to 85 years. Our clinical study on 42 subjects proves a size decrease of the monomeric fraction with age, whereby their relative frequency of occurrence decreases. The larger polymeric radius fractions which are detected in lenses of all subjects increase with their age. An increase of protein polymer size is likely to be linked to the decrease of the (gamma) -crystallin fraction in old eye lens nuclei. Our preliminary analysis of clinical results is corresponding to the chemical gradients parallel to the OA of the lenses which are reported by O. Hockwin after examination on extracted eye lenses. The normalization of the lens densitometric data derived after Scheimpflug- photography against the protein size fraction analysis by DLS is performed. As a comparison mean between both techniques on identical eye lenses, an absorption corrected densitometry is conducted for the first time.

  2. External ocular surface and lens microbiota in contact lens wearers with corneal infiltrates during extended wear of hydrogel lenses.

    PubMed

    Willcox, Mark; Sharma, Savitri; Naduvilath, Thomas J; Sankaridurg, Padmaja R; Gopinathan, Usha; Holden, Brien A

    2011-03-01

    To determine whether carriage of microbes on the contact lens or ocular surfaces during extended wear (EW) with soft hydroxyethyl methacrylate (HEMA)-based contact lenses predisposes the wearer to adverse events. Participants (non-contact lens wearers) were enrolled in a clinical study involving wear of HEMA-based hydrogel lenses on a six night EW basis with weekly replacement. Type and number of bacteria colonizing the lower lid margins, upper bulbar conjunctiva, and contact lenses during EW after one night, 1 week, 1 month, and thereafter every 3 months for 3.5 years were determined. The association of bacteria with adverse responses was compared between carriers (defined as having significant microbes cultured from two or more samples with 1 year) and noncarriers, and the strength of the association was estimated using multivariate logistic regression. Carriers of gram-positive bacteria on lenses (particularly coagulase negative staphylococci or Corynebacterium spp.) were approximately three and eight times more likely to develop contact lens-induced peripheral ulcers (CLPUs) and asymptomatic infiltrates (AIs), respectively. Staphylococcus aureus was most frequently isolated from lenses during CLPU. Carriers of gram-negative bacteria on lenses were five times more likely to develop contact lens-induced acute red eye (CLARE). Haemophilus influenzae was isolated most frequently from lenses during CLARE and AI events. Bacterial carriage on contact lenses during EW predisposes the wearer to the development of corneal inflammatory events including CLARE, CLPU, and AI.

  3. The performance of magnetic lens for focusing VCN-SANS

    NASA Astrophysics Data System (ADS)

    Nop Collaboration; Yamada, M.; Iwashita, Y.; Kanaya, T.; Ichikawa, M.; Tongu, H.; Kennedy, S. J.; Shimizu, H. M.; Mishima, K.; Yamada, N. L.; Hirota, K.; Carpenter, J. M.; Lal, J.; Andersen, K.; Geltenbort, P.; Guerard, B.; Manzin, G.; Hino, M.; Kitaguchi, M.; Bleuel, M.; NOP Collaboration

    2011-04-01

    We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5×104T/m2⩽g‧⩽5.9×104T/m2. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS.We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source (≈3mm) over a wavelength range of 30Å⩽λ⩽48Å in focal length of ≈1.14m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO)100(PPO)65(PEO)100 tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.

  4. Comparative Analysis of Tear Film Levels of Inflammatory Mediators in Contact Lens Users.

    PubMed

    Yüksel Elgin, Cansu; İskeleli, Güzin; Talaz, Serap; Akyol, Sibel

    2016-04-01

    To compare tear films levels of various inflammatory cytokines in asymptomatic contact lens (CL) users. CL users of rigid gas-permeable CLs (RGPCL) (group 1) or silicone hydrogel CLs (SiHCL) (group 2) were compared with non-CL-using healthy subjects (group 3). Tear samples were collected from subjects in each group after ensuring that there were no complications secondary to CL wear in the CL-wearing participants. Tear-film levels of interleukins (ILs)-1β, -6, and -8; granulocyte-macrophage colony-stimulating factor (GM-CSF) (using the Luminex method); and leukotriene B4 (LTB4) (using the ELISA method) were determined. Cytokine levels were compared among the three groups using analysis-of-variance (ANOVA) and Kruskall-Wallis tests. There were significant differences in concentrations of IL-1β, GM-CSF and LTB4 among the three groups (p = 0.002, p = 0.021 and p = 0.009, respectively), as shown by the Kruskall-Wallis test comparing all three groups for the three cytokines. There were no significant differences for IL-6 and IL-8 (p = 0.079 and 0.094, respectively) when all three groups were compared. There were substantial statistically significant differences between RGPCL users, SiHCL users and control subjects in levels of tear film cytokines. Although CL users were asymptomatic, changes in tear-film levels of several important inflammatory mediators revealed that a chronic inflammatory process occurs during CL wear.

  5. Versatile optical coherence tomography for imaging the human eye

    PubMed Central

    Tao, Aizhu; Shao, Yilei; Zhong, Jianguang; Jiang, Hong; Shen, Meixiao; Wang, Jianhua

    2013-01-01

    We demonstrated the feasibility of a CMOS-based spectral domain OCT (SD-OCT) for versatile ophthalmic applications of imaging the corneal epithelium, limbus, ocular surface, contact lens, crystalline lens, retina, and full eye in vivo. The system was based on a single spectrometer and an alternating reference arm with four mirrors. A galvanometer scanner was used to switch the reference beam among the four mirrors, depending on the imaging application. An axial resolution of 7.7 μm in air, a scan depth of up to 37.7 mm in air, and a scan speed of up to 70,000 A-lines per second were achieved. The approach has the capability to provide high-resolution imaging of the corneal epithelium, contact lens, ocular surface, and tear meniscus. Using two reference mirrors, the zero delay lines were alternatively placed on the front cornea or on the back lens. The entire ocular anterior segment was imaged by registering and overlapping the two images. The full eye through the pupil was measured when the reference arm was switched among the four reference mirrors. After mounting a 60 D lens in the sample arm, this SD-OCT was used to image the retina, including the macula and optical nerve head. This system demonstrates versatility and simplicity for multi-purpose ophthalmic applications. PMID:23847729

  6. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    NASA Astrophysics Data System (ADS)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, James H. H.; Suyu, Sherry H.; Chiueh, Tzihong

    Strong gravitationally lensed quasars provide powerful means to study galaxy evolution and cosmology. Current and upcoming imaging surveys will contain thousands of new lensed quasars, augmenting the existing sample by at least two orders of magnitude. To find such lens systems, we built a robot, Chitah, that hunts for lensed quasars by modeling the configuration of the multiple quasar images. Specifically, given an image of an object that might be a lensed quasar, Chitah first disentangles the light from the supposed lens galaxy and the light from the multiple quasar images based on color information. A simple rule is designed to categorize the given object as a potential four-image (quad) or two-image (double) lensed quasar system. The configuration of the identified quasar images is subsequently modeled to classify whether the object is a lensed quasar system. We test the performance of Chitah using simulated lens systems based on the Canada–France–Hawaii Telescope Legacy Survey. For bright quads with large image separations (with Einstein radiusmore » $${r}_{\\mathrm{ein}}\\gt 1\\buildrel{\\prime\\prime}\\over{.} 1$$) simulated using Gaussian point-spread functions, a high true-positive rate (TPR) of $$\\sim 90\\%$$ and a low false-positive rate of $$\\sim 3\\%$$ show that this is a promising approach to search for new lens systems. We obtain high TPR for lens systems with $${r}_{\\mathrm{ein}}\\gtrsim 0\\buildrel{\\prime\\prime}\\over{.} 5$$, so the performance of Chitah is set by the seeing. We further feed a known gravitational lens system, COSMOS 5921+0638, to Chitah, and demonstrate that Chitah is able to classify this real gravitational lens system successfully. Our newly built Chitah is omnivorous and can hunt in any ground-based imaging surveys.« less

  8. Dietary vitamin C and E modulates oxidative stress induced-kidney and lens injury in diabetic aged male rats through modulating glucose homeostasis and antioxidant systems.

    PubMed

    Özkaya, Dilek; Naziroğlu, Mustafa; Armağan, Abdullah; Demirel, Alpay; Köroglu, Banu Kale; Çolakoğlu, Neriman; Kükner, Aysel; Sönmez, Tolga Taha

    2011-06-01

    Diabetes induces oxidative stress in aged human and rat, although daily supplementation of vitamins C and E (VCE) can be beneficial to aged diabetic rats by reducing free radical production. The aim of the present study was to evaluate whether dietary VCE supplementation relieves oxidative stress in streptozotocin (STZ)-induced diabetic in aged rats. Thirty aged rats were randomly divided into three groups. The first group was used as a control. The second group was made diabetic using a single dose of intraperitoneal STZ. VCE-supplemented feed was given to aged diabetic rats constituting the third group. On the 21st day of the experiment, blood, lens and kidney samples were taken from all animals. Glutathione peroxidase (GSH-Px) activity in lens and kidney, reduced glutathione (GSH), vitamin E and β-carotene concentrations in kidney were lower in the diabetic group than in the control whereas plasma glucose, urea and creatinine, and kidney and lens peroxidation (LP) levels were higher in the diabetic group than in the control. However, kidney and lens LP levels, and plasma glucose, urea and creatinine values were decreased by VCE supplementation. Lens and kidney GSH-Px activity, kidney GSH, vitamin E and β-carotene concentrations and erythrocyte counts were increased by VCE treatment. Kidney weights, vitamin A, haemoglobin, hematocrit, leukocyte and platelets values were not changed by diabetes and/or VCE supplementation. VCE ameliorated also diabetes-induced histopathological changes in kidney. In conclusion, we observed that VCE supplementation is beneficial towards kidney and lens of aged diabetic rats by modulating oxidative and antioxidant systems. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Selective plane illumination microscopy (SPIM) with time-domain fluorescence lifetime imaging microscopy (FLIM) for volumetric measurement of cleared mouse brain samples

    NASA Astrophysics Data System (ADS)

    Funane, Tsukasa; Hou, Steven S.; Zoltowska, Katarzyna Marta; van Veluw, Susanne J.; Berezovska, Oksana; Kumar, Anand T. N.; Bacskai, Brian J.

    2018-05-01

    We have developed an imaging technique which combines selective plane illumination microscopy with time-domain fluorescence lifetime imaging microscopy (SPIM-FLIM) for three-dimensional volumetric imaging of cleared mouse brains with micro- to mesoscopic resolution. The main features of the microscope include a wavelength-adjustable pulsed laser source (Ti:sapphire) (near-infrared) laser, a BiBO frequency-doubling photonic crystal, a liquid chamber, an electrically focus-tunable lens, a cuvette based sample holder, and an air (dry) objective lens. The performance of the system was evaluated with a lifetime reference dye and micro-bead phantom measurements. Intensity and lifetime maps of three-dimensional human embryonic kidney (HEK) cell culture samples and cleared mouse brain samples expressing green fluorescent protein (GFP) (donor only) and green and red fluorescent protein [positive Förster (fluorescence) resonance energy transfer] were acquired. The results show that the SPIM-FLIM system can be used for sample sizes ranging from single cells to whole mouse organs and can serve as a powerful tool for medical and biological research.

  10. Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment.

    PubMed

    Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru

    2016-02-01

    To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P < .05). Statistically significant correlations were present between preoperative pupil diameters and postoperative visual acuities (Rs > 0; P < .05). Patients with a larger pupil always have better postoperative visual acuities. Meanwhile, there was no statistically significant correlation between pupil decentration and visual acuities (P > .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.

  11. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography

    PubMed Central

    Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability. PMID:28863141

  12. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

    PubMed

    Kimura, Shuhei; Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.

  13. Fast axial scanning for 2-photon microscopy using liquid lens technology.

    PubMed

    Tehrani, Kayvan Forouhesh; Sun, Min Kyoung; Karumbaiah, Lohitash; Mortensen, Luke J

    2017-03-01

    Scanning microscopy methods require movement of the focus in Z coordinates to produce an image of a 3-dimensional volume. In a typical imaging system, the optical setup is kept fixed and either the sample or the objective is translated with a mechanical stage driven by a stepper motor or a piezoelectric element. Mechanical Z scanning is precise, but its slow response and vulnerability to mechanical vibrations and stress make it disadvantageous to image dynamic, time-varying samples such as live cell structures. An alternative method less susceptible to these problems is to change the focal plane using conjugate optics. Deformable mirrors, acoustooptics, and electrically tunable lenses have been experimented with to achieve this goal and have attained very fast and precise Z-scanning without physically moving the sample. Here, we present the use of a liquid lens for fast axial scanning. Liquid lenses have a long functional life, high degree of phase shift, and low sensitivity to mechanical stress. They work on the principle of refraction at a liquid-liquid interface. At the boundary of a polar and an apolar liquid a spherical surface is formed whose curvature can be controlled by adjusting its relative wettability using electrowetting. We characterize the effects of the lens on attainable Z displacement, beam spectral characteristics, and pulse duration as compared with mechanical scanning.

  14. Fast axial scanning for 2-photon microscopy using liquid lens technology

    PubMed Central

    Tehrani, Kayvan Forouhesh; Sun, Min Kyoung; Karumbaiah, Lohitash; Mortensen, Luke J.

    2018-01-01

    Scanning microscopy methods require movement of the focus in Z coordinates to produce an image of a 3-dimensional volume. In a typical imaging system, the optical setup is kept fixed and either the sample or the objective is translated with a mechanical stage driven by a stepper motor or a piezoelectric element. Mechanical Z scanning is precise, but its slow response and vulnerability to mechanical vibrations and stress make it disadvantageous to image dynamic, time-varying samples such as live cell structures. An alternative method less susceptible to these problems is to change the focal plane using conjugate optics. Deformable mirrors, acoustooptics, and electrically tunable lenses have been experimented with to achieve this goal and have attained very fast and precise Z-scanning without physically moving the sample. Here, we present the use of a liquid lens for fast axial scanning. Liquid lenses have a long functional life, high degree of phase shift, and low sensitivity to mechanical stress. They work on the principle of refraction at a liquid-liquid interface. At the boundary of a polar and an apolar liquid a spherical surface is formed whose curvature can be controlled by adjusting its relative wettability using electrowetting. We characterize the effects of the lens on attainable Z displacement, beam spectral characteristics, and pulse duration as compared with mechanical scanning. PMID:29706682

  15. Impact of duration of contact lens wear on the structure and function of the meibomian glands.

    PubMed

    Alghamdi, Waleed M; Markoulli, Maria; Holden, Brien A; Papas, Eric B

    2016-03-01

    To investigate the effects of the duration of contact lens (CL) wear on the meibomian glands (MGs), eyelid and tear film. This was a cross-sectional study of CL wearers and non-wearers (NWs) aged between 18 and 35 years. The sample comprised of: (i) Three groups of CL wearers of different duration profiles (short, moderate and long experience of CL wear); (ii) a group of previous CL wearers (PWs) who had ceased wear for at least 6 months prior to the present study; (iii) healthy non-wearers as a control group. Study procedures were conducted in the order from least invasive to most invasive as follows: symptom assessment, lipid assessment, non-invasive break-up time, tear meniscus area, tear osmolarity and evaporation, Phenol red thread, MG expressibility, ocular surface and eyelid assessments, meibography, Marx line and lid wiper assessment using lissamine green. For statistical comparison of continuous data, one-way analysis of variance was used with Bonferroni post-hoc correction, where appropriate. Kruskal-Wallis test and Pearson Chi-Square respectively were used for ordinal and categorical variables. A total of 100 participants (49 males and 51 females; mean age ± SD: 25.4 ± 4.1) were enrolled across the five groups, such that each was composed of 20 age/sex matched individuals. Significant differences between the study groups were found for MG expressibility (p < 0.001), number of plugged orifices (p = 0.001), number of expressed orifices (p < 0.001), MG dropout (p = 0.001), Marx line score (p < 0.001), palpebral redness (p = 0.003), and roughness (p = 0.002), non-invasive break-up time (p < 0.001), Phenol red thread (p = 0.005), and tear meniscus area (p = 0.029). For all these variables, the NW group was statistically different from all other groups. Duration of wear was not a significant factor, except for Marx line score which was different in PWs compared to those with longer experience of CL wear (p = 0.03) CONCLUSION: Alterations to MG morphology and function accompany contact lens wear. Although these changes onset during the first 2 years of wear, prolonged CL exposure beyond this point does not appear to be associated with further modification. Cessation of wear for at up to 6 months does not lead to resolution. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  16. IgE antibody on worn highly oxygen-permeable silicone hydrogel contact lenses from patients with contact lens-induced papillary conjunctivitis (CLPC).

    PubMed

    Zhao, Zhenjun; Fu, Han; Skotnitsky, Cheryl C; Sankaridurg, Padmaja R; Willcox, Mark D P

    2008-03-01

    To investigate whether the level of IgE is increased in the eyes of patients during general contact lens-induced papillary conjunctivitis (CLPC) events, which involve enlarged papillae across the entire palpebral conjunctiva, or local CLPC events, in which papillae are confined to one or two parts of the area. Worn contact lenses were collected and soaked in phosphate-buffered saline. The levels of eluted IgE and IgE retained on contact lenses were detected by enzyme-linked immunosorbent assay. IgE was detected in 6 of 12 cases of general CLPC, 8 of 21 cases of local CLPC, and none of 14 control contact lenses. The average level of eluted IgE was 0.54 +/- 1.06 IU/contact lens, 0.28 +/- 0.54 IU/contact lens, and 0.04 +/- 0.06 IU/contact lens for general CLPC, local CLPC, and the control group, respectively. The incidences of positive IgE were significantly higher in patients with CLPC (general and local) than in control subjects, but no statistical difference was found between general and local CLPC. Generally higher amounts of retained IgE were detected on contact lenses that had increased levels of eluted IgE. Contact lenses that were collected before or after a CLPC event did not show increased levels of IgE. The level of IgE is increased in the eyes of some patients during an acute event of CLPC. The similar incidence of IgE-positive cases and levels of IgE from general and local CLPC contact lenses suggest that the conditions may share similar causal pathways.

  17. Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study

    PubMed Central

    Nacaroglu, Senay Asik; Un, Emine Seker; Ersoz, Mehmet Giray; Tasci, Yelda

    2015-01-01

    AIM To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). METHODS Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. RESULTS Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (P<0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT (P<0.001), while there was no difference between the measurements by GAT and RT (P=0.629). There was a good level of positive correlation between GAT and RTCL as well as RT (r=0.786 P<0.001, r=0.833 P<0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT (P=0.329), RTCL and GAT (P=0.07) as well as RT and GAT (P=0.189) in linear regression model. CONCLUSION The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population. PMID:26086004

  18. Anterior segment dysgenesis correlation with epithelial-mesenchymal transition in Smad4 knockout mice.

    PubMed

    Li, Jing; Qin, Yu; Zhao, Fang-Kun; Wu, Di; He, Xue-Fei; Liu, Jia; Zhao, Jiang-Yue; Zhang, Jin-Song

    2016-01-01

    To explore the molecular mechanisms in lens development and the pathogenesis of Peters anomaly in Smad4 defective mice. Le-Cre transgenic mouse line was employed to inactivate Smad4 in the surface ectoderm selectively. Pathological techniques were used to reveal the morphological changes of the anterior segment in Smad4 defective eye. Immunohistochemical staining was employed to observe the expression of E-cadherin, N-cadherin and α-SMA in anterior segment of Smad4 defective mice and control mice at embryonic (E) day 16.5. Real-time quantitative polymerase chain reaction (qPCR) was performed to detect the expression of Snail, Zeb1, Zeb2 and Twist2 in lens of Smad4 defective mice and control mice at E16.5. Statistical evaluations were performed using the unpaired Student's t-test (two-tailed) by SPSS 11.0 software. Conditional deletion of Smad4 on eye surface ectoderm resulted in corneal dysplasia, iridocorneal angle closure, corneolenticular adhesions and cataract resembling Peters anomaly. Loss of Smad4 function inhibited E-cadherin expression in the lens epithelium cells and corneal epithelium cells in Smad4 defective eye. Expression of N-cadherin was up-regulated in corneal epithelium and corneal stroma. Both E-cadherin and N-cadherin were down-regulated at the future trabecular meshwork region in mutant eye. The qPCR results showed that the expression of Twist2 was increased significantly in the mutant lens (P<0.01). Smad4 is essential to eye development and likely a candidate pathogenic gene to Peters anomaly by regulating epithelial-mesenchymal transition. Twist2 can be regulated by Smad4 and plays an essential role in lens development.

  19. Mocking the weak lensing universe: The LensTools Python computing package

    NASA Astrophysics Data System (ADS)

    Petri, A.

    2016-10-01

    We present a newly developed software package which implements a wide range of routines frequently used in Weak Gravitational Lensing (WL). With the continuously increasing size of the WL scientific community we feel that easy to use Application Program Interfaces (APIs) for common calculations are a necessity to ensure efficiency and coordination across different working groups. Coupled with existing open source codes, such as CAMB (Lewis et al., 2000) and Gadget2 (Springel, 2005), LensTools brings together a cosmic shear simulation pipeline which, complemented with a variety of WL feature measurement tools and parameter sampling routines, provides easy access to the numerics for theoretical studies of WL as well as for experiment forecasts. Being implemented in PYTHON (Rossum, 1995), LensTools takes full advantage of a range of state-of-the art techniques developed by the large and growing open-source software community (Jones et al., 2001; McKinney, 2010; Astrophy Collaboration, 2013; Pedregosa et al., 2011; Foreman-Mackey et al., 2013). We made the LensTools code available on the Python Package Index and published its documentation on http://lenstools.readthedocs.io.

  20. Linear and Non-Linear Thermal Lens Signal of the Fifth C-H Vibrational Overtone of Naphthalene in Liquid Solutions of Hexane

    NASA Astrophysics Data System (ADS)

    Manzanares, Carlos; Diaz, Marlon; Barton, Ann; Nyaupane, Parashu R.

    2017-06-01

    The thermal lens technique is applied to vibrational overtone spectroscopy of solutions of naphthalene in n-hexane. The pump and probe thermal lens technique is found to be very sensitive for detecting samples of low composition (ppm) in transparent solvents. In this experiment two different probe lasers: one at 488 nm and another 568 nm were used. The C-H fifth vibrational overtone spectrum of benzene is detected at room temperature for different concentrations. A plot of normalized integrated intensity as a function of concentration of naphthalene in solution reveals a non-linear behavior at low concentrations when using the 488 nm probe and a linear behavior over the entire range of concentrations when using the 568 nm probe. The non-linearity cannot be explained assuming solvent enhancement at low concentrations. A two color absorption model that includes the simultaneous absorption of the pump and probe lasers could explain the enhanced magnitude and the non-linear behavior of the thermal lens signal. Other possible mechanisms will also be discussed.

  1. Effects of Iris Surface Curvature on Iris Recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Joseph T; Flynn, Patrick J; Bowyer, Kevin W

    To focus on objects at various distances, the lens of the eye must change shape to adjust its refractive power. This change in lens shape causes a change in the shape of the iris surface which can be measured by examining the curvature of the iris. This work isolates the variable of iris curvature in the recognition process and shows that differences in iris curvature degrade matching ability. To our knowledge, no other work has examined the effects of varying iris curvature on matching ability. To examine this degradation, we conduct a matching experiment across pairs of images with varyingmore » degrees of iris curvature differences. The results show a statistically signi cant degradation in matching ability. Finally, the real world impact of these ndings is discussed« less

  2. Inferring monopartite projections of bipartite networks: an entropy-based approach

    NASA Astrophysics Data System (ADS)

    Saracco, Fabio; Straka, Mika J.; Di Clemente, Riccardo; Gabrielli, Andrea; Caldarelli, Guido; Squartini, Tiziano

    2017-05-01

    Bipartite networks are currently regarded as providing a major insight into the organization of many real-world systems, unveiling the mechanisms driving the interactions occurring between distinct groups of nodes. One of the most important issues encountered when modeling bipartite networks is devising a way to obtain a (monopartite) projection on the layer of interest, which preserves as much as possible the information encoded into the original bipartite structure. In the present paper we propose an algorithm to obtain statistically-validated projections of bipartite networks, according to which any two nodes sharing a statistically-significant number of neighbors are linked. Since assessing the statistical significance of nodes similarity requires a proper statistical benchmark, here we consider a set of four null models, defined within the exponential random graph framework. Our algorithm outputs a matrix of link-specific p-values, from which a validated projection is straightforwardly obtainable, upon running a multiple hypothesis testing procedure. Finally, we test our method on an economic network (i.e. the countries-products World Trade Web representation) and a social network (i.e. MovieLens, collecting the users’ ratings of a list of movies). In both cases non-trivial communities are detected: while projecting the World Trade Web on the countries layer reveals modules of similarly-industrialized nations, projecting it on the products layer allows communities characterized by an increasing level of complexity to be detected; in the second case, projecting MovieLens on the films layer allows clusters of movies whose affinity cannot be fully accounted for by genre similarity to be individuated.

  3. Quantitative bioimaging of trace elements in the human lens by LA-ICP-MS.

    PubMed

    Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; González-Iglesias, Héctor; Coca-Prados, Miguel; Sanz-Medel, Alfredo

    2014-04-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for the quantitative imaging of Fe, Cu and Zn in cryostat sections of human eye lenses and for depth profiling analysis in bovine lenses. To ensure a tight temperature control throughout the experiments, a new Peltier-cooled laser ablation cell was employed. For quantification purposes, matrix-matched laboratory standards were prepared from a pool of human lenses from eye donors and spiked with standard solutions containing different concentrations of natural abundance Fe, Cu and Zn. A normalisation strategy was also carried out to correct matrix effects, lack of tissue homogeneity and/or instrumental drifts using a thin gold film deposited on the sample surface. Quantitative images of cryo-sections of human eye lenses analysed by LA-ICP-MS revealed a homogeneous distribution of Fe, Cu and Zn in the nuclear region and a slight increase in Fe concentration in the outer cell layer (i.e. lens epithelium) at the anterior pole. These results were assessed also by isotope dilution mass spectrometry, and Fe, Cu and Zn concentrations determined by ID-ICP-MS in digested samples of lenses and lens capsules.

  4. Pathway to the Galactic Distribution of Planets: Combined Spitzer and Ground-Based Microlens Parallax Measurements of 21 Single-Lens Events

    NASA Technical Reports Server (NTRS)

    Novati, S. Calchi; Gould, A.; Udalski, A.; Menzies, J. W.; Bond, I. A.; Shvartzvald, Y.; Street, R. A.; Hundertmark, M.; Beichman, C. A.; Barry, R. K.

    2015-01-01

    We present microlens parallax measurements for 21 (apparently) isolated lenses observed toward the Galactic bulge that were imaged simultaneously from Earth and Spitzer, which was approximately 1 Astronomical Unit west of Earth in projection. We combine these measurements with a kinematic model of the Galaxy to derive distance estimates for each lens, with error bars that are small compared to the Sun's galactocentric distance. The ensemble therefore yields a well-defined cumulative distribution of lens distances. In principle, it is possible to compare this distribution against a set of planets detected in the same experiment in order to measure the Galactic distribution of planets. Since these Spitzer observations yielded only one planet, this is not yet possible in practice. However, it will become possible as larger samples are accumulated.

  5. Pathway to the Galactic Distribution of Planets: Combined Spitzer and Ground-Based Microlens Parallax Measurements of 21 Single-Lens Events

    NASA Astrophysics Data System (ADS)

    Calchi Novati, S.; Gould, A.; Udalski, A.; Menzies, J. W.; Bond, I. A.; Shvartzvald, Y.; Street, R. A.; Hundertmark, M.; Beichman, C. A.; Yee, J. C.; Carey, S.; Poleski, R.; Skowron, J.; Kozłowski, S.; Mróz, P.; Pietrukowicz, P.; Pietrzyński, G.; Szymański, M. K.; Soszyński, I.; Ulaczyk, K.; Wyrzykowski, Ł.; OGLE Collaboration; Albrow, M.; Beaulieu, J. P.; Caldwell, J. A. R.; Cassan, A.; Coutures, C.; Danielski, C.; Dominis Prester, D.; Donatowicz, J.; Lončarić, K.; McDougall, A.; Morales, J. C.; Ranc, C.; Zhu, W.; PLANET Collaboration; Abe, F.; Barry, R. K.; Bennett, D. P.; Bhattacharya, A.; Fukunaga, D.; Inayama, K.; Koshimoto, N.; Namba, S.; Sumi, T.; Suzuki, D.; Tristram, P. J.; Wakiyama, Y.; Yonehara, A.; MOA Collaboration; Maoz, D.; Kaspi, S.; Friedmann, M.; Wise Group; Bachelet, E.; Figuera Jaimes, R.; Bramich, D. M.; Tsapras, Y.; Horne, K.; Snodgrass, C.; Wambsganss, J.; Steele, I. A.; Kains, N.; RoboNet Collaboration; Bozza, V.; Dominik, M.; Jørgensen, U. G.; Alsubai, K. A.; Ciceri, S.; D'Ago, G.; Haugbølle, T.; Hessman, F. V.; Hinse, T. C.; Juncher, D.; Korhonen, H.; Mancini, L.; Popovas, A.; Rabus, M.; Rahvar, S.; Scarpetta, G.; Schmidt, R. W.; Skottfelt, J.; Southworth, J.; Starkey, D.; Surdej, J.; Wertz, O.; Zarucki, M.; MiNDSTEp Consortium; Gaudi, B. S.; Pogge, R. W.; DePoy, D. L.; μFUN Collaboration

    2015-05-01

    We present microlens parallax measurements for 21 (apparently) isolated lenses observed toward the Galactic bulge that were imaged simultaneously from Earth and Spitzer, which was ˜1 AU west of Earth in projection. We combine these measurements with a kinematic model of the Galaxy to derive distance estimates for each lens, with error bars that are small compared to the Sun’s galactocentric distance. The ensemble therefore yields a well-defined cumulative distribution of lens distances. In principle, it is possible to compare this distribution against a set of planets detected in the same experiment in order to measure the Galactic distribution of planets. Since these Spitzer observations yielded only one planet, this is not yet possible in practice. However, it will become possible as larger samples are accumulated.

  6. Photothermal trace detection in capillary electrophoresis for biomedical diagnostics and toxic materials (invited)

    NASA Astrophysics Data System (ADS)

    Faubel, Werner; Heissler, Stefan; Pyell, Ute; Ragozina, Natalia

    2003-01-01

    Two applications of a near-field thermal lens capillary electrophoresis detector in the deep ultraviolet region (pump beam 257 nm wavelength) will be presented: (1) Capillary electrophoretic determination of the pharmaceuticals Tramadol, Verapamil, and Papaverin. Direct separation techniques were used for the different classes of substances with characteristic absorbance spectra. The combination of capillary electrophoresis and the highly sensitive detection with thermal lens spectroscopy permits the analysis of nanoliter volume samples common in biomedical diagnostics without any preconcentration step. (2) The determination of (nonfluorescent) nitro aromatic explosives in contaminated soil. These compounds are detected with the laboratory built thermal lens detector after their separation by micellar electrokinetic chromatography. Its shown that this type of detection makes it possible to obtain limits of detection 1-2 orders of magnitude lower than those obtained with classical absorption spectrometric detection.

  7. Discovery of a bright microlensing event with planetary features towards the Taurus region: a super-Earth planet

    NASA Astrophysics Data System (ADS)

    Nucita, A. A.; Licchelli, D.; De Paolis, F.; Ingrosso, G.; Strafella, F.; Katysheva, N.; Shugarov, S.

    2018-05-01

    The transient event labelled as TCP J05074264+2447555 recently discovered towards the Taurus region was quickly recognized to be an ongoing microlensing event on a source located at distance of only 700-800 pc from Earth. Here, we show that observations with high sampling rate close to the time of maximum magnification revealed features that imply the presence of a binary lens system with very low-mass ratio components. We present a complete description of the binary lens system, which host an Earth-like planet with most likely mass of 9.2 ± 6.6 M⊕. Furthermore, the source estimated location and detailed Monte Carlo simulations allowed us to classify the event as due to the closest lens system, being at a distance of ≃380 pc and mass ≃0.25 M⊙.

  8. Laser-Induced Damage to Thin Film Dielectric Coatings.

    DTIC Science & Technology

    1980-10-01

    magnify and reimage the laser spot in the diagnostic Path B. Location [5] (see Figure (9)) is the equi- valent focal plane in Path B to that in Path A at...the thin film sample, (3] . The object distance is between the focal plane and the lens at [6) and the image distance is betv en the lens [6] and the...the equivalent focal plane in the diagnostic path and positioned so that the peak of the beam spatial profile falls on the pinhole. The diameter of the

  9. LC-MS display of the total modified amino acids in cataract lens proteins and in lens proteins glycated by ascorbic acid in vitro.

    PubMed

    Cheng, Rongzhu; Feng, Qi; Ortwerth, Beryl J

    2006-05-01

    We previously reported chromatographic evidence supporting the similarity of yellow chromophores isolated from aged human lens proteins, early brunescent cataract lens proteins and calf lens proteins ascorbylated in vitro [Cheng, R. et al. Biochimica et Biophysica Acta 1537, 14-26, 2001]. In this paper, new evidence supporting the chemical identity of the modified amino acids in these protein populations were collected by using a newly developed two-dimensional LC-MS mapping technique supported by tandem mass analysis of the major species. The pooled water-insoluble proteins from aged normal human lenses, early stage brunescent cataract lenses and calf lens proteins reacted with or without 20 mM ascorbic acid in air for 4 weeks were digested with a battery of proteolytic enzymes under argon to release the modified amino acids. Aliquots equivalent to 2.0 g of digested protein were subjected to size-exclusion chromatography on a Bio-Gel P-2 column and four major A330nm-absorbing peaks were collected. Peaks 1, 2 and 3, which contained most of the modified amino acids were concentrated and subjected to RP-HPLC/ESI-MS, and the mass elution maps were determined. The samples were again analyzed and those peaks with a 10(4) - 10(6) response factor were subjected to MS/MS analysis to identify the daughter ions of each modification. Mass spectrometric maps of peaks 1, 2 and 3 from cataract lenses showed 58, 40 and 55 mass values, respectively, ranging from 150 to 600 Da. Similar analyses of the peaks from digests of the ascorbylated calf lens proteins gave 81, 70 and 67 mass values, respectively, of which 100 were identical to the peaks in the cataract lens proteins. A total of 40 of the major species from each digest were analyzed by LC-MS/MS and 36 were shown to be identical. Calf lens proteins incubated without ascorbic acid showed several similar mass values, but the response factors were 100 to 1000-fold less for every modification. Based upon these data, we conclude that the majority of the major modified amino acids present in early stage brunescent Indian cataract lens proteins appear to arise as a result of ascorbic acid modification, and are presumably advanced glycation end-products.

  10. Fatigue Behavior of Porous Ti-6Al-4V Made by Laser-Engineered Net Shaping.

    PubMed

    Razavi, Seyed Mohammad Javad; Bordonaro, Giancarlo G; Ferro, Paolo; Torgersen, Jan; Berto, Filippo

    2018-02-12

    The fatigue behavior and fracture mechanisms of additively manufactured Ti-6Al-4V specimens are investigated in this study. Three sets of testing samples were fabricated for the assessment of fatigue life. The first batch of samples was built by using Laser-Engineered Net Shaping (LENS) technology, a Direct Energy Deposition (DED) method. Internal voids and defects were induced in a second batch of samples by changing LENS machine processing parameters. Fatigue performance of these samples is compared to the wrought Ti-6Al-4V samples. The effects of machine-induced porosity are assessed on mechanical properties and results are presented in the form of SN curves for the three sets of samples. Fracture mechanisms are examined by using Scanning Electron Microscopy (SEM) to characterize the morphological characteristics of the failure surface. Different fracture surface morphologies are observed for porous and non-porous specimens due to the combination of head write speed and laser power. Formation of defects such as pores, unmelted regions, and gas entrapments affect the failure mechanisms in porous specimens. Non-porous specimens exhibit fatigue properties comparable with that of the wrought specimens, but porous specimens are found to show a tremendous reduced fatigue strength.

  11. A distortion of very-high-redshift galaxy number counts by gravitational lensing.

    PubMed

    Wyithe, J Stuart B; Yan, Haojing; Windhorst, Rogier A; Mao, Shude

    2011-01-13

    The observed number counts of high-redshift galaxy candidates have been used to build up a statistical description of star-forming activity at redshift z ≳ 7, when galaxies reionized the Universe. Standard models predict that a high incidence of gravitational lensing will probably distort measurements of flux and number of these earliest galaxies. The raw probability of this happening has been estimated to be ∼0.5 per cent (refs 11, 12), but can be larger owing to observational biases. Here we report that gravitational lensing is likely to dominate the observed properties of galaxies with redshifts of z ≳ 12, when the instrumental limiting magnitude is expected to be brighter than the characteristic magnitude of the galaxy sample. The number counts could be modified by an order of magnitude, with most galaxies being part of multiply imaged systems, located less than 1 arcsec from brighter foreground galaxies at z ≈ 2. This lens-induced association of high-redshift and foreground galaxies has perhaps already been observed among a sample of galaxy candidates identified at z ≈ 10.6. Future surveys will need to be designed to account for a significant gravitational lensing bias in high-redshift galaxy samples.

  12. SPACE WARPS - I. Crowdsourcing the discovery of gravitational lenses

    NASA Astrophysics Data System (ADS)

    Marshall, Philip J.; Verma, Aprajita; More, Anupreeta; Davis, Christopher P.; More, Surhud; Kapadia, Amit; Parrish, Michael; Snyder, Chris; Wilcox, Julianne; Baeten, Elisabeth; Macmillan, Christine; Cornen, Claude; Baumer, Michael; Simpson, Edwin; Lintott, Chris J.; Miller, David; Paget, Edward; Simpson, Robert; Smith, Arfon M.; Küng, Rafael; Saha, Prasenjit; Collett, Thomas E.

    2016-01-01

    We describe SPACE WARPS, a novel gravitational lens discovery service that yields samples of high purity and completeness through crowdsourced visual inspection. Carefully produced colour composite images are displayed to volunteers via a web-based classification interface, which records their estimates of the positions of candidate lensed features. Images of simulated lenses, as well as real images which lack lenses, are inserted into the image stream at random intervals; this training set is used to give the volunteers instantaneous feedback on their performance, as well as to calibrate a model of the system that provides dynamical updates to the probability that a classified image contains a lens. Low-probability systems are retired from the site periodically, concentrating the sample towards a set of lens candidates. Having divided 160 deg2 of Canada-France-Hawaii Telescope Legacy Survey imaging into some 430 000 overlapping 82 by 82 arcsec tiles and displaying them on the site, we were joined by around 37 000 volunteers who contributed 11 million image classifications over the course of eight months. This stage 1 search reduced the sample to 3381 images containing candidates; these were then refined in stage 2 to yield a sample that we expect to be over 90 per cent complete and 30 per cent pure, based on our analysis of the volunteers performance on training images. We comment on the scalability of the SPACE WARPS system to the wide field survey era, based on our projection that searches of 105 images could be performed by a crowd of 105 volunteers in 6 d.

  13. Transport and biodegradation of creosote compounds in clayey till, a field experiment

    NASA Astrophysics Data System (ADS)

    Broholm, Kim; Nilsson, Bertel; Sidle, Roy C.; Arvin, Erik

    2000-02-01

    The transport and biodegradation of 12 organic compounds (toluene, phenol, o-cresol, 2,6-, 3,5-dimethylphenol, naphthalene, 1-methylnaphthalene, benzothiophene, dibenzofuran, indole, acridine, and quinoline) were studied at a field site located on the island of Funen, Denmark, where a clayey till 10-15 m deep overlies a sandy aquifer. The upper 4.8 m of till is highly fractured and the upper 2.5 m contains numerous root and worm holes. A 1.5-2 m thick sand lens is encountered within the till at a depth of 4.8 m. Sampling points were installed at depths of 2.5 m, 4 m, and in the sand lens (5.5 m) to monitor the downward migration of a chloride tracer and the organic compounds. Water containing organic compounds and chloride was infiltrated into a 4 m×4.8 m basin at a rate of 8.8 m 3 day -1 for 7 days. The mass of naphthalene relative to chloride was 0.39-0.98 for the sampling points located at a depth of 2.5 m, 0.11-0.61 for the sampling points located at a depth of 4 m, and 0-0.02 for the sampling points located in the sand lens. A similar pattern was observed for eight organic compounds for which reliable results were obtained (toluene, phenol, o-cresol, 2,6-, 3,5-dimethylphenol, 1-methylnaphthalene, benzothiophene, and quinoline). This shows that the organic compounds were attenuated during the downward migration through the till despite the high infiltration rate. The attenuation process may be attributed to biodegradation.

  14. Tonopen XL assessment of intraocular pressure through silicone hydrogel contact lenses.

    PubMed

    Schornack, Muriel; Rice, Melissa; Hodge, David

    2012-09-01

    To assess the accuracy of Tonopen XL measurement of intraocular pressure (IOP) through low-power (-0.25 to -3.00) and high power (-3.25 to -6.00) silicone hydrogel lenses of 3 different materials (galyfilcon A, senofilcon A, and lotrafilcon B). Seventy-eight patients were recruited for participation in this study. All were habitual wearers of silicone hydrogel contact lenses, and none had been diagnosed with glaucoma, ocular hypertension, or anterior surface disease. IOP was measured with and without lenses in place in the right eye only. Patients were randomized to initial measurement either with or without the lens in place. A single examiner collected all data. No statistically significant differences were noted between IOP measured without lenses and IOP measured through low-power lotrafilcon B lenses or high-power or low-power galyfilcon A and senofilcon A lenses. However, we did find a statistically significant difference between IOP measured without lenses and IOP measured through high-power lotrafilcon B lenses. In general, Tonopen XL measurement of IOP through silicone hydrogel lenses may be sufficiently accurate for clinical purposes. However, Tonopen XL may overestimate IOP if performed through a silicone hydrogel lens of relatively high modulus.

  15. Statistical-thermodynamic model for light scattering from eye lens protein mixtures

    NASA Astrophysics Data System (ADS)

    Bell, Michael M.; Ross, David S.; Bautista, Maurino P.; Shahmohamad, Hossein; Langner, Andreas; Hamilton, John F.; Lahnovych, Carrie N.; Thurston, George M.

    2017-02-01

    We model light-scattering cross sections of concentrated aqueous mixtures of the bovine eye lens proteins γB- and α-crystallin by adapting a statistical-thermodynamic model of mixtures of spheres with short-range attractions. The model reproduces measured static light scattering cross sections, or Rayleigh ratios, of γB-α mixtures from dilute concentrations where light scattering intensity depends on molecular weights and virial coefficients, to realistically high concentration protein mixtures like those of the lens. The model relates γB-γB and γB-α attraction strengths and the γB-α size ratio to the free energy curvatures that set light scattering efficiency in tandem with protein refractive index increments. The model includes (i) hard-sphere α-α interactions, which create short-range order and transparency at high protein concentrations, (ii) short-range attractive plus hard-core γ-γ interactions, which produce intense light scattering and liquid-liquid phase separation in aqueous γ-crystallin solutions, and (iii) short-range attractive plus hard-core γ-α interactions, which strongly influence highly non-additive light scattering and phase separation in concentrated γ-α mixtures. The model reveals a new lens transparency mechanism, that prominent equilibrium composition fluctuations can be perpendicular to the refractive index gradient. The model reproduces the concave-up dependence of the Rayleigh ratio on α/γ composition at high concentrations, its concave-down nature at intermediate concentrations, non-monotonic dependence of light scattering on γ-α attraction strength, and more intricate, temperature-dependent features. We analytically compute the mixed virial series for light scattering efficiency through third order for the sticky-sphere mixture, and find that the full model represents the available light scattering data at concentrations several times those where the second and third mixed virial contributions fail. The model indicates that increased γ-γ attraction can raise γ-α mixture light scattering far more than it does for solutions of γ-crystallin alone, and can produce marked turbidity tens of degrees celsius above liquid-liquid separation.

  16. Galaxy-Galaxy Lensing in the Hubble Deep Field: The Halo Tully-Fisher Relation at Intermediate Redshift

    NASA Astrophysics Data System (ADS)

    Hudson, Michael J.; Gwyn, Stephen D. J.; Dahle, Håkon; Kaiser, Nick

    1998-08-01

    A tangential distortion of background source galaxies around foreground lens galaxies in the Hubble Deep Field is detected at the 99.3% confidence level. An important element of our analysis is the use of photometric redshifts to determine distances of lens and source galaxies and rest-frame B-band luminosities of the lens galaxies. The lens galaxy halos obey a Tully-Fisher relation between halo circular velocity and luminosity. The typical lens galaxy, at a redshift z = 0.6, has a circular velocity of 210 +/- 40 km s-1 at MB = -18.5, if q0 = 0.5. Control tests, in which lens and source positions and source ellipticities are randomized, confirm the significance level of the detection quoted above. Furthermore, a marginal signal is also detected from an independent, fainter sample of source galaxies without photometric redshifts. Potential systematic effects, such as contamination by aligned satellite galaxies, the distortion of source shapes by the light of the foreground galaxies, PSF anisotropies, and contributions from mass distributed on the scale of galaxy groups are shown to be negligible. A comparison of our result with the local Tully-Fisher relation indicates that intermediate-redshift galaxies are fainter than local spirals by 1.0 +/- 0.6 B mag at a fixed circular velocity. This is consistent with some spectroscopic studies of the rotation curves of intermediate-redshift galaxies. This result suggests that the strong increase in the global luminosity density with redshift is dominated by evolution in the galaxy number density.

  17. Lens-free microscopy of cerebrospinal fluid for the laboratory diagnosis of meningitis

    NASA Astrophysics Data System (ADS)

    Delacroix, Robin; Morel, Sophie Nhu An; Hervé, Lionel; Bordy, Thomas; Blandin, Pierre; Dinten, Jean-Marc; Drancourt, Michel; Allier, Cédric

    2018-02-01

    The cytology of the cerebrospinal fluid is traditionally performed by an operator (physician, biologist) by means of a conventional light microscope. The operator visually counts the leukocytes (white blood cells) present in a sample of cerebrospinal fluid (10 μl). It is a tedious job and the result is operator-dependent. Here in order to circumvent the limitations of manual counting, we approach the question of numeration of erythrocytes and leukocytes for the cytological diagnosis of meningitis by means of lens-free microscopy. In a first step, a prospective counts of leukocytes was performed by five different operators using conventional optical microscopy. The visual counting yielded an overall 16.7% misclassification of 72 cerebrospinal fluid specimens in meningitis/non-meningitis categories using a 10 leukocyte/μL cut-off. In a second step, the lens-free microscopy algorithm was adapted step-by-step for counting cerebrospinal fluid cells and discriminating leukocytes from erythrocytes. The optimization of the automatic lens-free counting was based on the prospective analysis of 215 cerebrospinal fluid specimens. The optimized algorithm yielded a 100% sensitivity and a 86% specificity compared to confirmed diagnostics. In a third step, a blind lens-free microscopic analysis of 116 cerebrospinal fluid specimens, including six cases of microbiology confirmed infectious meningitis, yielded a 100% sensitivity and a 79% specificity. Adapted lens-free microscopy is thus emerging as an operator-independent technique for the rapid numeration of leukocytes and erythrocytes in cerebrospinal fluid. In particular, this technique is well suited to the rapid diagnosis of meningitis at point-of-care laboratories.

  18. Gravitational lensing of gravitational waves: a statistical perspective

    NASA Astrophysics Data System (ADS)

    Li, Shun-Sheng; Mao, Shude; Zhao, Yuetong; Lu, Youjun

    2018-05-01

    In this paper, we study the strong gravitational lensing of gravitational waves (GWs) from a statistical perspective, with particular focus on the high frequency GWs from stellar binary black hole coalescences. These are most promising targets for ground-based detectors such as Advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and the proposed Einstein Telescope (ET) and can be safely treated under the geometrical optics limit for GW propagation. We perform a thorough calculation of the lensing rate, by taking account of effects caused by the ellipticity of lensing galaxies, lens environments, and magnification bias. We find that in certain GW source rate scenarios, we should be able to observe strongly lensed GW events once per year (˜1 yr-1) in the aLIGO survey at its design sensitivity; for the proposed ET survey, the rate could be as high as ˜80 yr-1. These results depend on the estimate of GW source abundance, and hence can be correspondingly modified with an improvement in our understanding of the merger rate of stellar binary black holes. We also compute the fraction of four-image lens systems in each survey, predicting it to be ˜30 per cent for the aLIGO survey and ˜6 per cent for the ET survey. Finally, we evaluate the possibility of missing some images due to the finite survey duration, by presenting the probability distribution of lensing time delays. We predict that this selection bias will be insignificant in future GW surveys, as most of the lens systems ({˜ } 90{per cent}) will have time delays less than ˜1 month, which will be far shorter than survey durations.

  19. Dynamic Contour Tonometry (DCT) over a thin daily disposable hydrogel contact lens.

    PubMed

    Nosch, Daniela Sonja; Duddek, Armin P; Herrmann, Didier; Stuhrmann, Oliver M

    2010-10-01

    Dynamic Contour Tonometry (DCT) has been shown to measure the intraocular pressure (IOP) independent of corneal physical properties such as thickness, curvature and rigidity. The aim of this study was to find out if DCT remains accurate when it is applied on regularly shaped corneas while a thin, daily hydrogel contact lens (CL) is worn. This was a prospective, randomised study and included 46 patients (46 right eyes): 26 females and 20 males. The age varied from 22 to 66 years (mean: 43.0+/-12.70 years). IOP and ocular pulse amplitude (OPA) measurements were taken with and without a daily disposable hydrogel CL (-0.50 D), Filcon IV) in situ (using the DCT), with a randomised order of measurements. The average value for the IOP measurements without CL was 16.51+/-3.20 mmHg, and with CL in situ it was 16.10+/-3.10 mmHg. The mean difference was 0.41 mmHg and not found to be statistically significant (p=0.074). The average value for the OPA measurement without CL was 2.20+/-0.79 mmHg. With CL in situ it was 2.08+/-0.81 mmHg. This gave a mean difference of 0.11 mmHg and was statistically significant (p=0.025). The Bland-Altman plot showed a maximum difference in IOP of +2.44 and -2.00 mmHg (CI 0.95). Regarding OPA, the maximum difference was +0.81 and -0.60 mmHg (CI 0.95). The presence of a thin hydrogel CL did not affect the accuracy of IOP measurements using the DCT. The ocular pulse amplitude was measured on average 5.45% lower with a CL in situ. Copyright (c) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Statistics of Microlensing Caustic Crossings in Q 2237+0305: Peculiar Velocity of the Lens Galaxy and Accretion Disk Size

    NASA Astrophysics Data System (ADS)

    Mediavilla, E.; Jimenez-Vicente, J.; Muñoz, J. A.; Mediavilla, T.; Ariza, O.

    2015-01-01

    We use the statistics of caustic crossings induced by microlensing in the lens system Q 2237+0305 to study the lens galaxy peculiar velocity. We calculate the caustic crossing rates for a comprehensive family of stellar mass functions and find a dependence of the average number of caustic crossings with the effective transverse velocity and the average mass, < n > \\propto {veff / \\sqrt{< m > }}, equivalent to the theoretical prediction for the case of microlenses with identical masses. We explore the possibilities of the method to measure v eff using the ~12 yr of Optical Gravitational Lensing Experiment monitoring of the four images of Q 2237+0305. To determine a lower limit for v eff, we count, conservatively, a single caustic crossing for each one of the four high magnification events identified in the literature (plus one additional proposed by us) obtaining veff ≳ 240\\sqrt{< m > /0.17 M_⊙ } km s-1 at 68% of confidence. From this value and the average FWHM of the four high magnification events, we obtain a lower limit of rs ≳ 1.4 \\sqrt{< m > /0.17 M_⊙ } light-days for the radius of the source (rs = FWHM/2.35). Tentative identification of three additional caustic crossing events leads to estimates of veff≃ (493+/- 246)\\sqrt{< m > /0.17 M_⊙ } km s-1 for the effective transverse velocity and of rs ≃ (2.7+/- 1.3)\\sqrt{< m > /0.17 M_⊙ } light-days for the source size. The estimated transverse peculiar velocity of the galaxy is vt ≃ (429+/- 246)\\sqrt{< m > /0.17 M_⊙ } km s-1.

  1. In vitro and in vivo evaluation of novel ciprofloxacin-releasing silicone hydrogel contact lenses.

    PubMed

    Hui, Alex; Willcox, Mark; Jones, Lyndon

    2014-07-15

    The purpose of this study was to evaluate ciprofloxacin-releasing silicone hydrogel contact lens materials in vitro and in vivo for the treatment of microbial keratitis. Model silicone hydrogel contact lens materials were manufactured using a molecular imprinting technique to modify ciprofloxacin release kinetics. Various contact lens properties, including light transmission and surface wettability, were determined, and the in vitro ciprofloxacin release kinetics elucidated using fluorescence spectrophotometry. The materials then were evaluated for their ability to inhibit Pseudomonas aeruginosa growth in vitro and in an in vivo rabbit model of microbial keratitis. Synthesized lenses had similar material properties to commercial contact lens materials. There was a decrease in light transmission in the shorter wavelengths due to incorporation of the antibiotic, but over 80% light transmission between 400 and 700 nm. Modified materials released for more than 8 hours, significantly longer than unmodified controls (P < 0.05). In vivo, there was no statistically significant difference between the number of colony-forming units (CFU) recovered from corneas treated with eye drops and those treated with one of two modified contact lenses (P > 0.05), which is significantly less than corneas treated with unmodified control lenses or those that received no treatment at all (P < 0.05). These novel contact lenses designed for the extended release of ciprofloxacin may be beneficial to supplement or augment future treatments of sight-threatening microbial keratitis. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  2. Asymptomatic corneal staining associated with the use of balafilcon silicone-hydrogel contact lenses disinfected with a polyaminopropyl biguanide-preserved care regimen.

    PubMed

    Jones, Lyndon; MacDougall, Nancy; Sorbara, L Gina

    2002-12-01

    To compare subjective symptoms and signs in a group of individuals who wear silicone-hydrogel lenses on a daily wear basis while they sequentially used two differing care regimens. Fifty adapted soft-lens wearers were fitted with a silicone-hydrogel lens material (PureVision, Bausch & Lomb). The lenses were worn on a daily wear basis for two consecutive 1-month periods, during which the subjects used either a Polyquad (polyquaternium-1) -based system or a polyaminopropyl biguanide (PHMB) -based system, using a double-masked, randomized, crossover experimental design. Significant levels of relatively asymptomatic corneal staining were observed when subjects used the PHMB-based system, with 37% of subjects demonstrating a level of staining consistent with a classical solution-based toxicity reaction. Only 2% of the subjects exhibited such staining when using the Polyquad-based system. These results were significantly different (p < 0.001). Significant symptoms were not correlated with the degree of staining, with no differences in lens comfort or overall preference being reported between the regimens (p = NS). The only statistically significant difference in symptoms related to minor differences in stinging after lens insertion being reported, with the Polyquad-based system demonstrating less stinging (p < 0.008). Practitioners who fit silicone-hydrogel contact lenses on a daily wear basis should be wary of the potential for certain PHMB-containing multipurpose care systems to invoke corneal staining. Switching to non-PHMB based regimens will eliminate this complication in most instances.

  3. Development of a Double-Gauss Lens Based Setup for Optoacoustic Applications

    PubMed Central

    Choi, Hojong; Ryu, Jae-Myung; Yeom, Jung-Yeol

    2017-01-01

    In optoacoustic (photoacoustic) systems, different echo signal intensities such as amplitudes, center frequencies, and bandwidths need to be compensated by utilizing variable gain or time-gain compensation amplifiers. However, such electronic components can increase system complexities and signal noise levels. In this paper, we introduce a double-Gauss lens to generate a large field of view with uniform light intensity due to the low chromatic aberrations of the lens, thus obtaining uniform echo signal intensities across the field of view of the optoacoustic system. In order to validate the uniformity of the echo signal intensities in the system, an in-house transducer was placed at various positions above a tissue sample and echo signals were measured and compared with each other. The custom designed double-Gauss lens demonstrated negligible light intensity variation (±1.5%) across the illumination field of view (~2 cm diameter). When the transducer was used to measure echo signal from an eye of a bigeye tuna within a range of ±1 cm, the peak-to-peak amplitude, center frequency, and their −6 dB bandwidth variations were less than 2 mV, 1 MHz, and 6%, respectively. The custom designed double-Gauss lens can provide uniform light beam across a wide area while generating insignificant echo signal variations, and thus can lower the burden of the receiving electronics or signal processing in the optoacoustic system. PMID:28273794

  4. Polymorphisms in sodium-dependent vitamin C transporter genes and plasma, aqueous humor and lens nucleus ascorbate concentrations in an ascorbate depleted setting.

    PubMed

    Senthilkumari, Srinivasan; Talwar, Badri; Dharmalingam, Kuppamuthu; Ravindran, Ravilla D; Jayanthi, Ramamurthy; Sundaresan, Periasamy; Saravanan, Charu; Young, Ian S; Dangour, Alan D; Fletcher, Astrid E

    2014-07-01

    We have previously reported low concentrations of plasma ascorbate and low dietary vitamin C intake in the older Indian population and a strong inverse association of these with cataract. Little is known about ascorbate levels in aqueous humor and lens in populations habitually depleted of ascorbate and no studies in any setting have investigated whether genetic polymorphisms influence ascorbate levels in ocular tissues. Our objectives were to investigate relationships between ascorbate concentrations in plasma, aqueous humor and lens and whether these relationships are influenced by Single Nucleotide Polymorphisms (SNPs) in sodium-dependent vitamin C transporter genes (SLC23A1 and SLC23A2). We enrolled sixty patients (equal numbers of men and women, mean age 63 years) undergoing small incision cataract surgery in southern India. We measured ascorbate concentrations in plasma, aqueous humor and lens nucleus using high performance liquid chromatography. SLC23A1 SNPs (rs4257763, rs6596473) and SLC23A2 SNPs (rs1279683 and rs12479919) were genotyped using a TaqMan assay. Patients were interviewed for lifestyle factors which might influence ascorbate. Plasma vitamin C was normalized by a log10 transformation. Statistical analysis used linear regression with the slope of the within-subject associations estimated using beta (β) coefficients. The ascorbate concentrations (μmol/L) were: plasma ascorbate, median and inter-quartile range (IQR), 15.2 (7.8, 34.5), mean (SD) of aqueous humor ascorbate, 1074 (545) and lens nucleus ascorbate, 0.42 (0.16) (μmol/g lens nucleus wet weight). Minimum allele frequencies were: rs1279683 (0.28), rs12479919 (0.30), rs659647 (0.48). Decreasing concentrations of ocular ascorbate from the common to the rare genotype were observed for rs6596473 and rs12479919. The per allele difference in aqueous humor ascorbate for rs6596473 was -217 μmol/L, p < 0.04 and a per allele difference in lens nucleus ascorbate of -0.085 μmol/g, p < 0.02 for rs12479919. The β coefficients for the regression of log10 plasma ascorbate on aqueous humor ascorbate were higher for the GG genotype of rs6596473: GG, β = 1460 compared to carriage of the C allele, CG, β = 1059, CC, β = 1132, p interaction = 0.1. In conclusion we found that compared to studies in well-nourished populations, ascorbate concentrations in the plasma, aqueous humor and lens nucleus were low. We present novel findings that polymorphisms in SLC23A1/2 genes influenced ascorbate concentration in aqueous humor and lens nucleus. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Low-kilovolt coherent electron diffractive imaging instrument based on a single-atom electron source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Chun-Yueh; Chang, Wei-Tse; Chen, Yi-Sheng

    2016-03-15

    In this work, a transmission-type, low-kilovolt coherent electron diffractive imaging instrument was constructed. It comprised a single-atom field emitter, a triple-element electrostatic lens, a sample holder, and a retractable delay line detector to record the diffraction patterns at different positions behind the sample. It was designed to image materials thinner than 3 nm. The authors analyzed the asymmetric triple-element electrostatic lens for focusing the electron beams and achieved a focused beam spot of 87 nm on the sample plane at the electron energy of 2 kV. High-angle coherent diffraction patterns of a suspended graphene sample corresponding to (0.62 Å){sup −1} were recorded. This workmore » demonstrated the potential of coherent diffractive imaging of thin two-dimensional materials, biological molecules, and nano-objects at a voltage between 1 and 10 kV. The ultimate goal of this instrument is to achieve atomic resolution of these materials with high contrast and little radiation damage.« less

  6. Toward a Galactic Distribution of Planets. I. Methodology and Planet Sensitivities of the 2015 High-cadence Spitzer Microlens Sample

    NASA Astrophysics Data System (ADS)

    Zhu, Wei; Udalski, A.; Calchi Novati, S.; Chung, S.-J.; Jung, Y. K.; Ryu, Y.-H.; Shin, I.-G.; Gould, A.; Lee, C.-U.; Albrow, M. D.; Yee, J. C.; Han, C.; Hwang, K.-H.; Cha, S.-M.; Kim, D.-J.; Kim, H.-W.; Kim, S.-L.; Kim, Y.-H.; Lee, Y.; Park, B.-G.; Pogge, R. W.; KMTNet Collaboration; Poleski, R.; Mróz, P.; Pietrukowicz, P.; Skowron, J.; Szymański, M. K.; KozLowski, S.; Ulaczyk, K.; Pawlak, M.; OGLE Collaboration; Beichman, C.; Bryden, G.; Carey, S.; Fausnaugh, M.; Gaudi, B. S.; Henderson, C. B.; Shvartzvald, Y.; Wibking, B.; Spitzer Team

    2017-11-01

    We analyze an ensemble of microlensing events from the 2015 Spitzer microlensing campaign, all of which were densely monitored by ground-based high-cadence survey teams. The simultaneous observations from Spitzer and the ground yield measurements of the microlensing parallax vector {{\\boldsymbol{π }}}{{E}}, from which compact constraints on the microlens properties are derived, including ≲25% uncertainties on the lens mass and distance. With the current sample, we demonstrate that the majority of microlenses are indeed in the mass range of M dwarfs. The planet sensitivities of all 41 events in the sample are calculated, from which we provide constraints on the planet distribution function. In particular, assuming a planet distribution function that is uniform in {log}q, where q is the planet-to-star mass ratio, we find a 95% upper limit on the fraction of stars that host typical microlensing planets of 49%, which is consistent with previous studies. Based on this planet-free sample, we develop the methodology to statistically study the Galactic distribution of planets using microlensing parallax measurements. Under the assumption that the planet distributions are the same in the bulge as in the disk, we predict that ∼1/3 of all planet detections from the microlensing campaigns with Spitzer should be in the bulge. This prediction will be tested with a much larger sample, and deviations from it can be used to constrain the abundance of planets in the bulge relative to the disk.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kozlowski, M.F.; Maricle, S.; Mouser, R.

    A statistics-based model is being developed to predict the laser-damage-limited lifetime of UV optical components on the NIF laser. In order to provide data for the model, laser damage experiments were performed on the Beamlet laser system at LLNL. An early prototype NIF focus lens was exposed to twenty 35 1 nm pulses at an average fluence of 5 J/cm{sup 2}, 3ns. Using a high resolution optic inspection system a total of 353 damage sites was detected within the 1160 cm{sup 2} beam aperture. Through inspections of the lens before, after and, in some cases, during the campaign, pulse tomore » pulse damage growth rates were measured for damage initiating both on the surface and at bulk inclusions. Growth rates as high as 79 {micro}m/pulse (surface diameter) were observed for damage initiating at pre-existing scratches in the surface. For most damage sites on the optic, both surface and bulk, the damage growth rate was approximately l0{micro}m/pulse. The lens was also used in Beamlet for a subsequent 1053 {micro}m/526 {micro}m campaign. The 352 {micro}m-initiated damage continued to grow during that campaign although at generally lower growth rate.« less

  8. Study on warning radius of diffuse reflection laser warning based on fish-eye lens

    NASA Astrophysics Data System (ADS)

    Chen, Bolin; Zhang, Weian

    2013-09-01

    The diffuse reflection type of omni-directional laser warning based on fish-eye lens is becoming more and more important. As one of the key parameters of warning system, the warning radius should be put into investigation emphatically. The paper firstly theoretically analyzes the energy detected by single pixel of FPA detector in the system under complicated environment. Then the least energy detectable by each single pixel of the system is computed in terms of detector sensitivity, system noise, and minimum SNR. Subsequently, by comparison between the energy detected by single pixel and the least detectable energy, the warning radius is deduced from Torrance-Sparrow five-parameter semiempirical statistic model. Finally, a field experiment was developed to validate the computational results. It has been found that the warning radius has a close relationship with BRDF parameters of the irradiated target, propagation distance, angle of incidence, and detector sensitivity, etc. Furthermore, an important fact is shown that the experimental values of warning radius are always less than that of theoretical ones, due to such factors as the optical aberration of fish-eye lens, the transmissivity of narrowband filter, and the packing ratio of detector.

  9. A comparison of cosmological models using strong gravitational lensing galaxies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melia, Fulvio; Wei, Jun-Jie; Wu, Xue-Feng, E-mail: fmelia@email.arizona.edu, E-mail: jjwei@pmo.ac.cn, E-mail: xfwu@pmo.ac.cn, E-mail: fmelia@email.arizona.edu, E-mail: jjwei@pmo.ac.cn, E-mail: xfwu@pmo.ac.cn

    2015-01-01

    Strongly gravitationally lensed quasar-galaxy systems allow us to compare competing cosmologies as long as one can be reasonably sure of the mass distribution within the intervening lens. In this paper, we assemble a catalog of 69 such systems from the Sloan Lens ACS and Lens Structure and Dynamics surveys suitable for this analysis, and carry out a one-on-one comparison between the standard model, ΛCDM, and the R{sub h}=ct universe, which has thus far been favored by the application of model selection tools to other kinds of data. We find that both models account for the lens observations quite well, thoughmore » the precision of these measurements does not appear to be good enough to favor one model over the other. Part of the reason is the so-called bulge-halo conspiracy that, on average, results in a baryonic velocity dispersion within a fraction of the optical effective radius virtually identical to that expected for the whole luminous-dark matter distribution modeled as a singular isothermal ellipsoid, though with some scatter among individual sources. Future work can greatly improve the precision of these measurements by focusing on lensing systems with galaxies as close as possible to the background sources. Given the limitations of doing precision cosmological testing using the current sample, we also carry out Monte Carlo simulations based on the current lens measurements to estimate how large the source catalog would have to be in order to rule out either model at a ∼99.7% confidence level. We find that if the real cosmology is ΛCDM, a sample of ∼200 strong gravitational lenses would be sufficient to rule out R{sub h}=ct at this level of accuracy, while ∼300 strong gravitational lenses would be required to rule out ΛCDM if the real universe were instead R{sub h}=ct. The difference in required sample size reflects the greater number of free parameters available to fit the data with ΛCDM. We point out that, should the R{sub h}=ct universe eventually emerge as the correct cosmology, its lack of any free parameters for this kind of work will provide a remarkably powerful probe of the mass structure in lensing galaxies, and a means of better understanding the origin of the bulge-halo conspiracy.« less

  10. In-line polariscopic checking of plastic molded-injected lenses: preliminary results

    NASA Astrophysics Data System (ADS)

    Arasa, J.; Mayershofer, D.; Romero, J.

    2015-05-01

    Plastic injection molded lenses have improved its performance and, nowadays, are as usual as glass lenses in image forming devices. However, the manufacturing process induces the surface generation and the material transformation in the same stage. Moreover, the process also includes an annealing stage to remove the internal stress with temperature cycles but only works up to a certain level and not beyond, leaving relevant traces for high values. During the manufacturing process of a plastic lens, a liquid-solid phase transformation occurs, and in this transition not all the volume of the lens achieves the same density. This change of density is translated into a local change of refractive index that can be expressed as a retardation phase plane using the Jones Matrix notation. The detection and measurement of the value of the retardation of the phase plane is thus the clue to manufacture good and controlled quality plastic lenses. We have tested an in-line polariscopic arrangement to obtain a 2D map of the tension distribution in the bulk of the lens. This test is performed in the first 30 seconds after the injection molding process for two main reasons: first the stress values are still high because the lenses do not have enough time to relax the internal tensions and obtain the final shape, and second, we can remove the wrong lenses in the first moments and introduce only the good lenses in the annealing stage. The proposed instrument is based in a transmission polariscopic arrangement. A collimated light beam is used to illuminate the sample, once the light crosses the sample, it is collected with an afocal system and the image is recorded in a CMOS sensor. Selecting an afocal system to capture the image is a useful decision because the lateral magnification can be maintained when small changes in the sample position are introduced. However the produced lenses can vary their focal lengths from on series to another. To avoid problems with the change of the focal length, the lens is introduced in a matching index and the polariscopic measurement is done. The proposed polariscopic arrangement uses two lineal polarizers, one acting as polarizer and the other acting as analyzer. This system instead of using one lineal polarizer and a lineal polarizer with an extra lambda/4 plate provides us an extra degree of freedom, enabling the possibility to put a certain degree of polarization in a well determined position of the lens, in our case the center of this lens. The aim of this study is to select the minimum number of sets polarizer-analyzer and the right wavelengths to obtain a sure selection of the right lens. The preliminary results show that use two different wavelengths 470 & 627 nm is a good option to obtain a robust image. The second free variables that must be adjusted to obtain good values is the minimum number of set polarizer-analyzer necessary to obtain confident results. In our first tests it seems that recording only at 0, 15, 30 and 45 degrees is enough to get good results. Mathematica description and first results for a PMMA lens are presented, however the number of measurements must be diminished to obtain an easy in-line implementation

  11. [Power in the periphery of several aspheric eyeglasses for aphakic patients].

    PubMed

    Simonet, P

    1984-01-01

    A special device adapted to a Nikon projection vertexometer permits the power to be measured in the periphery of recent aspheric aphakic lenses. The peripheral power is measured with respect to the vertex sphere. A blended lenticular aspheric lens and three types of zonal aspheric full field lenses are studied, with various base curves on three samples. Four meridians of each lens are evaluated with ocular rotations varying by 5 degrees step up to 35 degrees at least. The results show a variable oblique astigmatism and a high under-correction of the mean oblique power for the Welsh 4 drop. The other zonal aspheric lenses give only a slight improvement of the peripheral powers compared with some conventional aspheric lenses. The Omega lens shows a reasonable correction of off-axis power errors up to 30 degrees. Beyond, the powers variation follows the general characteristics of blended lenticular aspheric lenses.

  12. An Electromagnetic Sensor with a Metamaterial Lens for Nondestructive Evaluation of Composite Materials

    PubMed Central

    Savin, Adriana; Steigmann, Rozina; Bruma, Alina; Šturm, Roman

    2015-01-01

    This paper proposes the study and implementation of a sensor with a metamaterial (MM) lens in electromagnetic nondestructive evaluation (eNDE). Thus, the use of a new type of MM, named Conical Swiss Rolls (CSR) has been proposed. These structures can serve as electromagnetic flux concentrators in the radiofrequency range. As a direct application, plates of composite materials with carbon fibers woven as reinforcement and polyphenylene sulphide as matrix with delaminations due to low energy impacts were examined. The evaluation method is based on the appearance of evanescent modes in the space between carbon fibers when the sample is excited with a transversal magnetic along z axis (TMz) polarized electromagnetic field. The MM lens allows the transmission and intensification of evanescent waves. The characteristics of carbon fibers woven structure became visible and delaminations are clearly emphasized. The flaws can be localized with spatial resolution better than λ/2000. PMID:26151206

  13. The optical lens coupled X-ray in-line phase contrast imaging system for the characterization of low Z materials

    NASA Astrophysics Data System (ADS)

    Wang, Kai; Lin, Wei; Dai, Fei; Li, Jun; Qi, Xiaobo; Lei, Haile; Liu, Yuanqiong

    2018-05-01

    Due to the high spatial resolution and contrast, the optical lens coupled X-ray in-line phase contrast imaging system with the secondary optical magnification is more suitable for the characterization of the low Z materials. The influence of the source to object distance and the object to scintillator distance on the image resolution and contrast is studied experimentally. A phase correlation algorithm is used for the image mosaic of a serial of X-ray phase contrast images acquired with high resolution, the resulting resolution is less than 1.0 μm, and the whole field of view is larger than 1.4 mm. Finally, the geometric morphology and the inner structure of various weakly absorbing samples and the evaporation of water in the plastic micro-shell are in situ characterized by the optical lens coupled X-ray in-line phase contrast imaging system.

  14. Feasibility study of the application of radially polarized illumination to solid immersion lens-based near-field optics.

    PubMed

    Yoon, Yong-Joong; Kim, Wan-Chin; Park, No-Cheol; Park, Kyoung-Su; Park, Young-Pil

    2009-07-01

    We analyzed the behavior of the electric field in a focal plane consisting of a solid immersion lens (SIL), an air gap, and a measurement sample for radially polarized illumination in SIL-based near-field optics with an annular aperture. The analysis was based on the Debye diffraction integral and multiple beam interference. For SIL-based near-field optics whose NA is higher than unity, radially polarized light generates a smaller beam spot on the bottom surface of a SIL than circularly polarized light; however, the beam spot on the measurement sample is broadened with a more dominant transverse electric field. By introducing an annular aperture technique, it is possible to decrease the effects of the transverse electric field, and therefore the size of the beam spot on the measurement sample can be small. This analysis could have various applications in near-field optical storage, near-field microscopy, lithography at ultrahigh resolution, and other applications that use SILs for high resolution.

  15. eV-TEM: Transmission electron microscopy in a low energy cathode lens instrument.

    PubMed

    Geelen, Daniël; Thete, Aniket; Schaff, Oliver; Kaiser, Alexander; van der Molen, Sense Jan; Tromp, Rudolf

    2015-12-01

    We are developing a transmission electron microscope that operates at extremely low electron energies, 0-40 eV. We call this technique eV-TEM. Its feasibility is based on the fact that at very low electron energies the number of energy loss pathways decreases. Hence, the electron inelastic mean free path increases dramatically. eV-TEM will enable us to study elastic and inelastic interactions of electrons with thin samples. With the recent development of aberration correction in cathode lens instruments, a spatial resolution of a few nm appears within range, even for these very low electron energies. Such resolution will be highly relevant to study biological samples such as proteins and cell membranes. The low electron energies minimize adverse effects due to radiation damage. Copyright © 2015. Published by Elsevier B.V.

  16. Camera, Hand Lens, and Microscope Probe (CHAMP): An Instrument Proposed for the 2009 MSL Rover Mission

    NASA Technical Reports Server (NTRS)

    Mungas, Greg S.; Beegle, Luther W.; Boynton, John E.; Lee, Pascal; Shidemantle, Ritch; Fisher, Ted

    2004-01-01

    The Camera, Hand Lens, and Microscope Probe (CHAMP) will allow examination of martian surface features and materials (terrain, rocks, soils, samples) on spatial scales ranging from kilometers to micrometers, thus enabling both microscopy and context imaging with high operational flexibility. CHAMP is designed to allow the detailed and quantitative investigation of a wide range of geologic features and processes on Mars, leading to a better quantitative understanding of the evolution of the martian surface environment through time. In particular, CHAMP will provide key data that will help understand the local region explored by Mars Surface Laboratory (MSL) as a potential habitat for life. CHAMP will also support other anticipated MSL investigations, in particular by helping identify and select the highest priority targets for sample collection and analysis by the MSL's analytical suite.

  17. All-optical optoacoustic microscopy system based on probe beam deflection technique

    NASA Astrophysics Data System (ADS)

    Maswadi, Saher M.; Tsyboulskic, Dmitri; Roth, Caleb C.; Glickman, Randolph D.; Beier, Hope T.; Oraevsky, Alexander A.; Ibey, Bennett L.

    2016-03-01

    It is difficult to achieve sub-micron resolution in backward mode OA microscopy using conventional piezoelectric detectors, because of wavefront distortions caused by components placed in the optical path, between the sample and the objective lens, that are required to separate the acoustic wave from the optical beam. As an alternate approach, an optoacoustic microscope (OAM) was constructed using the probe beam deflection technique (PBDT) to detect laserinduced acoustic signals. The all-optical OAM detects laser-generated pressure waves using a probe beam passing through a coupling medium, such as water, filling the space between the microscope objective lens and sample. The acoustic waves generated in the sample propagate through the coupling medium, causing transient changes in the refractive index that deflect the probe beam. These deflections are measured with a high-speed, balanced photodiode position detector. The deflection amplitude is directly proportional to the magnitude of the acoustic pressure wave, and provides the data required for image reconstruction. The sensitivity of the PBDT detector expressed as noise equivalent pressure was 12 Pa, comparable to that of existing high-performance ultrasound detectors. Because of the unimpeded working distance, a high numerical aperture objective lens, i.e. NA = 1, was employed in the OAM to achieve near diffraction-limited lateral resolution of 0.5 μm at 532nm. The all-optical OAM provides several benefits over current piezoelectric detector-based systems, such as increased lateral and axial resolution, higher sensitivity, robustness, and potentially more compatibility with multimodal instruments.

  18. Aberration correction considering curved sample surface shape for non-contact two-photon excitation microscopy with spatial light modulator.

    PubMed

    Matsumoto, Naoya; Konno, Alu; Inoue, Takashi; Okazaki, Shigetoshi

    2018-06-18

    In this paper, excitation light wavefront modulation is performed considering the curved sample surface shape to demonstrate high-quality deep observation using two-photon excitation microscopy (TPM) with a dry objective lens. A large spherical aberration typically occurs when the refractive index (RI) interface between air and the sample is a plane perpendicular to the optical axis. Moreover, the curved sample surface shape and the RI mismatch cause various aberrations, including spherical ones. Consequently, the fluorescence intensity and resolution of the obtained image are degraded in the deep regions. To improve them, we designed a pre-distortion wavefront for correcting the aberration caused by the curved sample surface shape by using a novel, simple optical path length difference calculation method. The excitation light wavefront is modulated to the pre-distortion wavefront by a spatial light modulator incorporated in the TPM system before passing through the interface, where the RI mismatch occurs. Thus, the excitation light is condensed without aberrations. Blood vessels were thereby observed up to an optical depth of 2,000 μm in a cleared mouse brain by using a dry objective lens.

  19. Change in over-refraction after scleral lens settling on average corneas.

    PubMed

    Bray, Chelsea; Britton, Stephanie; Yeung, Debby; Haines, Lacey; Sorbara, Luigina

    2017-07-01

    The purpose of this study was to determine the change in over-refraction, if any, after a scleral lens settled on the eye for 6-8 h. Sixteen patients of varying refractive errors and normal corneal curvatures (measured with Pentacam ™ Oculus) were fitted with trial Mini-Scleral Design (MSD) scleral lenses (15.8 mm diameter) in one eye. The sagittal depths of the scleral lenses were selected by adding 350 μm to the corneal sagittal heights measured at a chord length of 15 mm with the Visante ™ optical coherence tomographer (OCT) anterior segment scans and picking the closest available trial lens in the set. Initial measurements were taken 30 min after lens insertion and included an auto-refraction, subjective refraction, and best sphere refraction over the contact lens. Visual acuities and Visante ™ OCT anterior segment scans were also taken. These measurements were repeated after 6-8 h of lens wear. Over the trial wearing period, the average change in the spherical component of the over-refraction was +0.06 D (S.D. 0.17) (p = 0.16). The average change in cylinder was +0.04 D (S.D. 0.19) (p = 0.33). The average absolute change in axis was 1.06° (S.D. 12.11) (p = 0.74). The average change in best sphere was +0.13 ± 0.30 D (p = 0.12). There was no significant change in visual acuity with the best sphere over-refraction over the 6-8 h wearing period. There was a significant change in central corneal clearance over the wearing period of 83 μm (S.D. 22) (p < 0.0001). Despite a significant change in the central corneal clearance due to thinning of the fluid reservoir as the scleral lens settled (an average decrease of 83 μm after wearing the lenses for 6-8 h), there was not a statistically significant change in the subjective over-refraction (sphere, cylinder, and axis) or best sphere or visual acuity. This study has confirmed that there is no link between reduction in central corneal clearance and change in over-refraction for average corneas. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  20. The influence of lens power and center thickness on the intraocular pressure measured through soft lenses: a comparison of two noncontact tonometers.

    PubMed

    Ogbuehi, Kelechi C

    2012-06-01

    To quantify the influence of soft contact lens power and thickness on the intraocular pressure (IOP). Thirty-nine young, healthy adult volunteers completed this study. One eye of each subject was randomly assigned either a +6D or a -6D high water content daily disposable lens. The other eye was fitted with the second lens. Triplicate measurements of IOP were taken before, during, and after contact lens wear. Each time, IOP was assessed in a randomized order with two noncontact tonometers. The lenses were swapped between eyes during a second session of measurements, one week later. In the first session with the +6D lenses, the average IOPs (±SDs) before, with the lenses fitted, and after the lenses were removed, were: 14.3 ± 2.9 mmHg, 17.0 ± 3.3 mmHg and 13.9 ± 3.1 mmHg, respectively, for the CT80 and 13.6 ± 3.1 mmHg, 17.1 ± 4.5 mmHg and 13.3 ± 2.9 mmHg, respectively, for the PT100. The corresponding values for the first session with the -6D lenses were: 14.3 ± 3.1 mmHg, 13.1 ± 3.1 mmHg and 14.1 ± 3.3 mmHg, respectively, for the CT80 and 13.6 ± 3.2 mmHg, 13.0 ± 3.0 mmHg and 13.6 ± 3.2 mmHg, respectively, for the PT100. IOP significantly (P<0.05) increased (+ΔIOP=2.7 ± 0.4 mmHg with the CT80 in the first session) with the +6D lenses, but decreased (P<0.05) when the -6D lenses were fitted (-ΔIOP=0.6 ± 0.2 mmHg with the PT100 in the first session). The soft contact lens-induced changes were consistent between sessions but varied between tonometers. The measurement of IOP through soft contact lenses resulted in consistent, statistically significant differences in IOP, which were not uniform across tonometers and which did not appear to be solely related to the central thickness of the soft contact lenses. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. Image processing and data reduction of Apollo low light level photographs

    NASA Technical Reports Server (NTRS)

    Alvord, G. C.

    1975-01-01

    The removal of the lens induced vignetting from a selected sample of the Apollo low light level photographs is discussed. The methods used were developed earlier. A study of the effect of noise on vignetting removal and the comparability of the Apollo 35mm Nikon lens vignetting was also undertaken. The vignetting removal was successful to about 10% photometry, and noise has a severe effect on the useful photometric output data. Separate vignetting functions must be used for different flights since the vignetting function varies from camera to camera in size and shape.

  2. Absolute OH Number Density Measurements in Lean Fuel-Air Mixtures Excited by a Repetitively Pulsed Nanosecond Discharge

    DTIC Science & Technology

    2013-01-01

    cross section quartz channel with wall thickness of 1.75 mm. Two plane quartz windows are fused to the ends of the channel at Brewster angle (for ~308...ttp :// ar c. ai aa .o rg | D O I: 1 0. 25 14 /6 .2 01 3- 43 2 4 about 1 J/pulse, softly focused over the flame using a lens with a focal...region with an f=550 mm lens . The LIF signal sampling volume was about 100 mm away from the laser focal point, to avoid transition saturation. The

  3. Nonlocal nonlinear refractive index of gold nanoparticles synthesized by ascorbic acid reduction: comparison of fitting models.

    PubMed

    Balbuena Ortega, A; Arroyo Carrasco, M L; Méndez Otero, M M; Gayou, V L; Delgado Macuil, R; Martínez Gutiérrez, H; Iturbe Castillo, M D

    2014-12-12

    In this paper, the nonlinear refractive index of colloidal gold nanoparticles under continuous wave illumination is investigated with the z -scan technique. Gold nanoparticles were synthesized using ascorbic acid as reductant, phosphates as stabilizer and cetyltrimethylammonium chloride (CTAC) as surfactant agent. The nanoparticle size was controlled with the CTAC concentration. Experiments changing incident power and sample concentration were done. The experimental z -scan results were fitted with three models: thermal lens, aberrant thermal lens and the nonlocal model. It is shown that the nonlocal model reproduces with exceptionally good agreement; the obtained experimental behaviour.

  4. Thermal lens and all optical switching of new organometallic compound doped polyacrylamide gel

    NASA Astrophysics Data System (ADS)

    Badran, Hussain Ali

    In this work thermal lens spectrometry (TLS) is applied to investigate the thermo-optical properties of new organometallic compound containing azomethine group, Dichloro bis [2-(2-hydroxybenzylideneamino)-5-methylphenyl] telluride platinum(II), doped polyacrylamide gel using transistor-transistor logic (TTL) modulated cw 532 nm laser beam as an excitation beam modulated at 10 Hz frequency and probe beam wavelength 635 nm at 14 mW. The technique is applied to determine the thermal diffusivities, ds/dT and the linear thermal expansion coefficient of the sample. All-optical switching effects with low background and high stability are demonstrated.

  5. Quasi-mosaicity of (311) planes in silicon and its use in a Laue lens with high-focusing power

    NASA Astrophysics Data System (ADS)

    Camattari, Riccardo; Paternò, Gianfranco; Bellucci, Valerio; Guidi, Vincenzo

    2014-12-01

    (311) curved planes can be exploited for efficiently focus hard X-rays. With this purpose, a self-standing bent crystal was manufactured at the Sensor and Semiconductor Laboratory of Ferrara (Italy). The crystal was designed as an optical component for a X-ray concentrator such as a Laue lens. The curvature of (311) planes was obtained through the quasi-mosaic effect. The diffraction efficiency of the sample was tested at the Institut Laue Langevin of Grenoble (France) by using a collimated monochromatic X-ray beam. This was the first prove of the diffraction properties of (311) quasi-mosaic planes. Diffraction efficiency resulted 35 % with a 182 keV X-ray beam, in agreement with the theoretical expectation. It corresponded to a reflectivity of 33 %. While the chosen orientation is not the most performing lying of planes, it can be used, in addition to smaller-index planes, in order to raise the total effective area of a Laue lens. To quantify it, a Laue lens based on quasi-mosaic silicon and germanium crystals, exploiting (111), (422) and (311) diffracting planes, was achieved and simulated with the LaueGen code.

  6. Volumetric HiLo microscopy employing an electrically tunable lens.

    PubMed

    Philipp, Katrin; Smolarski, André; Koukourakis, Nektarios; Fischer, Andreas; Stürmer, Moritz; Wallrabe, Ulrike; Czarske, Jürgen W

    2016-06-27

    Electrically tunable lenses exhibit strong potential for fast motion-free axial scanning in a variety of microscopes. However, they also lead to a degradation of the achievable resolution because of aberrations and misalignment between illumination and detection optics that are induced by the scan itself. Additionally, the typically nonlinear relation between actuation voltage and axial displacement leads to over- or under-sampled frame acquisition in most microscopic techniques because of their static depth-of-field. To overcome these limitations, we present an Adaptive-Lens-High-and-Low-frequency (AL-HiLo) microscope that enables volumetric measurements employing an electrically tunable lens. By using speckle-patterned illumination, we ensure stability against aberrations of the electrically tunable lens. Its depth-of-field can be adjusted a-posteriori and hence enables to create flexible scans, which compensates for irregular axial measurement positions. The adaptive HiLo microscope provides an axial scanning range of 1 mm with an axial resolution of about 4 μm and sub-micron lateral resolution over the full scanning range. Proof of concept measurements at home-built specimens as well as zebrafish embryos with reporter gene-driven fluorescence in the thyroid gland are shown.

  7. Aberration design of zoom lens systems using thick lens modules.

    PubMed

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  8. Noncontact optical measurement of lens capsule thickness ex vivo

    NASA Astrophysics Data System (ADS)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  9. Rapid hydrothermal cooling above the axial melt lens at fast-spreading mid-ocean ridge: Quantification through intra-plagioclase diffusion revealed by IODP Hole 1256D

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Koepke, J.; Kirchner, C.; Götze, N.; Behrens, H.

    2014-12-01

    At fast-spreading mid-ocean ridges the axial melt lenses sandwiched between the lower oceanic crust and the sheeted dike sequences are assumed to be the major magma source of oceanic crust accretion. According to the widely discussed "gabbro glacier" model, the formation of the lower oceanic crust requires efficient cooling of the axial melt lens, resulting in partly crystallization and leading to crystal-melt mush which may subside down to form the lower crust. These processes are believed to be controlled dominantly by periodical magma supply and hydrothermal circulation above melt lens. Here we quantify the cooling rate above melt lens using chemical zoning of plagioclase from hornfelsic recrystallized sheeted dikes overlying the uppermost gabbros, which are part of the dike-gabbro transition zone drilled in Hole 1256D in the Eastern equatorial Pacific by the Integrated Ocean Drilling Program, where for the first time the dike-gabbro transition zone of an intact oceanic crust was penetrated and sampled. The measured zoning patterns are supposed to be a combined result of diffusion during both on-ridge and off-ridge cooling. We estimate the on-ridge cooling rate using a forward modelling approach based on CaAl-NaSi interdiffusion in plagioclase. The results show that the recrystallized sheeted dikes have been cooled from the peak thermal overprint at 1000-1050 °C to 600 °C within about 5-30 years as a result of hydrothermal circulation above a melt lens during a period of magma starvation, corresponding to a cooling rate of 30±15 °C/yr. Heat balance calculation also approves that in order to balance the heat output of a melt lens at a fast-spreading mid-ocean ridge similar to the case of IODP Hole 1256D, the cooling rate above the melt lens is required to be around 30 °C/yr. The estimated rapid hydrothermal cooling rate coincides with the observed annual to decal episodes of melt lens fluctuation and lava eruption, which favors the "gabbro glacier" model and explains how the effective heat extraction from melt lens is achieved at fast-spreading mid-ocean ridges.

  10. Corneal higher-order aberrations after phacoemulsification: a comparison of 3 different incision sizes.

    PubMed

    von Sonnleithner, Christoph; Pilger, Daniel; Homburg, David; Brockmann, Tobias; Torun, Necip; Bertelmann, Eckart

    2017-06-26

    To analyze the impact of different incision sizes for phacoemulsification on corneal higher-order aberrations (HOA). Patients seeking cataract surgery were randomly assigned to one of the following groups: 1.4 mm with biaxial microincision phacoemulsification (25 eyes), 1.8 mm with coaxial phacoemulsification (27 eyes), and 2.2 mm with coaxial phacoemulsification (62 eyes). Inclusion criteria were a minimum age of 18 years and uncomplicated cataract. Exclusion criteria were history of ocular trauma or intraocular surgery, any sign of inflammation or infection, pseudoexfoliation syndrome, glaucoma, optic atrophy, diabetic retinopathy, lens dislocation, cataracta intumescens, cataracta matura, and corneal diseases. Patients underwent phacoemulsification with implantation of an intraocular lens. Aberrometry was performed using an iTrace aberrometer with a pupil scan size of 5.0 mm preoperatively and at postoperative follow-up visits after 1 month. The paired sample t test and analysis of covariance were used for statistical analysis. Ninety patients (114 eyes) were enrolled (mean age 73.7 ± 8.9 years). In all groups, an increase of total HOAs could be measured. The strongest increase was seen in the 2.2 mm group (mean difference 0.031 [95% confidence interval (CI) 0.006-0.056], p = 0.014) and in the 1.4 mm group (mean difference 0.035 [95% CI -0.007 to 0078], p = 0.097). No important difference was found in the 1.8 mm group. The 2.2 mm and the 1.4 mm incisions seem to have a higher impact on corneal HOAs in comparison to the 1.8 mm incision.

  11. The weight of racism: Vigilance and racial inequalities in weight-related measures

    PubMed Central

    Hicken, Margaret T.; Lee, Hedwig; Hing, Anna K.

    2017-01-01

    In the United States, racial/ethnic inequalities in obesity are well-documented, particularly among women. Using the Chicago Community Adult Health Study, a probability-based sample in 2001–2003 (N=3,105), we examined the roles of discrimination and vigilance in racial inequalities in two weight-related measures, body mass index (BMI) and waist circumference (WC), viewed through a cultural racism lens. Cultural racism creates a social environment in which Black Americans bear the stigma burden of their racial group while White Americans are allowed to view themselves as individuals. We propose that in this context, interpersonal discrimination holds a different meaning for Blacks and Whites, while vigilance captures the coping style for Blacks who carry the stigma burden of the racial group. By placing discrimination and vigilance within the context of cultural racism, we operationalize existing survey measures and utilize statistical models to clarify the ambiguous associations between discrimination and weight-related inequalities in the extant literature. Multivariate models were estimated for BMI and WC separately and were stratified by gender. Black women had higher mean BMI and WC than any other group, as well as highest levels of vigilance. White women did not show an association between vigilance and WC but did show a strong positive association between discrimination and WC. Conversely, Black women displayed an association between vigilance and WC, but not between discrimination and WC. These results demonstrate that vigilance and discrimination may hold different meanings for obesity by ethnoracial group that are concealed when all women are examined together and viewed without considering a cultural racism lens. PMID:28372829

  12. Lens growth and protein changes in the eastern grey kangaroo.

    PubMed

    Augusteyn, Robert C

    2011-01-01

    Development in marsupials takes place predominantly ex utero while the young is attached to a nipple in the mother's pouch, very different from that in other species. This study was undertaken to examine whether this affects lens growth and the production of lens proteins in kangaroos. Fresh lenses were obtained at official culls from eastern gray kangaroos (Macropus giganteus). Wet weights were recorded for all and protein contents were determined for one lens from each animal. Dry weights, after fixation were obtained for 20 lenses. Ages were determined using both molar progression and total lens protein content. Lenses were divided into concentric layers by controlled dissolution using phosphate buffered saline. Samples were taken for determination of protein contents and dry weights, which were then used to determine the age of the layer removed. Soluble crystallin distributions were determined by fractionation of the centrifuged extracts using HPLC-GPC and the polypeptide contents of both soluble and insoluble proteins were assessed by SDS-PAGE. Lens growth is continuous from birth throughout adulthood and the increases in wet weight and fixed dry weight can be described with a single logistic growth functions for the whole life span. Three major crystallin classes, α-, β-, and γ-crystallins, were identified in the immature pouch-young animals aged around 60 days after birth. Adult lenses contain, in addition, the taxon-specific μ-crystallin. The proportions of these vary with the age of the lens tissue due to age related insolubilization as well as changes in the synthesis patterns. During early lactation (birth to 190 days), the α-, β-, and γ-crystallins represent 25, 53, and 20% of the total protein, respectively. After the pouch-young first releases the nipple (190 days), there is a rapid decrease in the production of γ-crystallins to around 5% of the total and a corresponding increase in μ-crystallin, from 0.5% to 15%. These changes were complete by the time the animal was fully weaned, around 1.5 years, and the final proportions of the 4 protein classes were maintained for the rest of life. The solubilities of α- and β-crystallins in the center of the lens decreased after age 5 years. Kangaroo lens growth is asymptotic, similar to that in most other species, even though most development of the young animal takes place ex utero. Changes in the patterns of lens protein synthesis in the kangaroo are similar to those observed in other species except for the large decrease in γ-crystallin and the matching increase in the marsupial-specific μ-crystallin, during late lactation.

  13. Prevalence of Batrachochytrium dendrobatidis in Agalychnis moreletii (Hylidae) of El Salvador and association with larval jaw sheath depigmentation.

    PubMed

    Lawson, Tyler D; Jones, Martin L; Komar, Oliver; Welch, Allison M

    2011-07-01

    Amphibian populations around the world have been declining at an alarming rate due to factors such as habitat destruction, pollution, and infectious diseases. Between May and July 2008, we investigated a fungal pathogen in the critically endangered Morelet's treefrog (Agalychnis moreletii) at sites in El Salvador. Larvae were screened with a hand lens for indications of infection with Batrachochytrium dendrobatidis (Bd), a fungus that can cause lethal chytridiomycosis in amphibians. Subsets of inspected tadpoles were preserved for analysis by polymerase chain reaction to determine the effectiveness of hand lens screening for presence of Bd and to estimate infection prevalence at various sites. Because individuals with signs of infection were preferentially included, we used a novel method to generate unbiased estimates of infection prevalence from these biased samples. External mouthpart deformities, identified with a hand lens, successfully predicted Bd infection across a large spatial scale. Two of 13 sites sampled had high (≥ 89%) estimated prevalence, whereas little or no Bd was detected at the remaining sites. Although it appears that A. moreletii populations in this region are not suffering rapid declines due to Bd, further monitoring is required to determine the extent to which these populations are stably coexisting with the pathogen.

  14. Evaluation of the Tear Function Tests and the Ocular Surface in First-Time Users of Silicone Hydrogel Contact Lenses.

    PubMed

    Yildiz Tasci, Yelda; Gürdal, Canan; Sarac, Ozge; Onusever, Aykut

    2017-07-01

    To evaluate the effects of three different silicone hydrogel contact lenses (SHCL), (balafilcon A, senofilcon A, and comfilcon A) on tear function tests, corneal thickness, and ocular surface cytology in first time contact lens users. In this prospective study, 120 eyes of 60 subjects were evaluated. Balafilcon A users were designated as group 1, senofilcon A users as group 2, and comfilcon A users as group 3. In all cases, before and after 6 months of contact lens wear, ocular surface disease index score (OSDI), tear breakup time (TBUT), Schirmer 1 test, central corneal thickness (CCT), central corneal epithelium thickness (CCET), and conjunctival impression cytology samples were evaluated. In group 1, 40 eyes of the 20 patients, in group 2, 40 eyes of the 20 patients, and in group 3, 40 eyes of the 20 patients were evaluated. The mean OSDI scores did not differ between the three groups after contact lens wear (p > 0.05). In group 1 and group 2, significant decrease was found in the mean TBUT 6 months after contact lens wear (p = 0.04, p < 0.001, respectively). In group 3, after 6 months of contact lens wear, the mean Schirmer 1 tear test was decreased significantly (p = 0.021). In all 3 groups, no significant change was observed in the mean CCT and CCET after contact lens wear (p > 0.05). After 6 months, the morphological changes in temporal and superior conjunctival epithelial cells were found to be significant in all groups (p < 0.001). Six months after SHCL wear, marked morphological changes occurred in the conjunctival epithelium. Tear function tests were also affected, while corneal thickness did not show any significant difference.

  15. Novel device for male infertility screening with single-ball lens microscope and smartphone.

    PubMed

    Kobori, Yoshitomo; Pfanner, Peter; Prins, Gail S; Niederberger, Craig

    2016-09-01

    To investigate the usefulness of a novel semen analysis device consisting of a single-ball lens microscope paired with a state-of-the-art smartphone equipped with a camera. Laboratory investigation. University research laboratory. A total of 50 semen samples obtained from volunteers were analyzed for count, concentration, and motility with an 0.8-mm ball lens and three types of smartphone. Comparisons were made with results obtained with a laboratory-based computer-assisted sperm analysis (CASA) system. None. Sperm concentration; sperm motility. Sperm concentration counted with a ball lens and each smartphone showed a very strong correlation with the CASA results. Likewise, sperm motility calculated with our device showed significant correlations to CASA. If eight spermatozoa or fewer were found on the field of view of an iPhone 6s, the semen specimens were considered to be below the lower reference limit for sperm concentration of World Health Organization 2010 guidelines (15 × 10(6) spermatozoa/mL). The sensitivity was 87.5%, and specificity was 90.9%. Smartphones have great potential to analyze semen because they are portable, contain excellent digital cameras, and can be easily attached to a microscope. A single-ball lens microscope is inexpensive and easy to use for acquiring digital microscopic movies. Given its small size and weight, the device can support testing for male fertility at home or in the field, making it much more convenient and economical than current practice. This single-ball lens microscope provides an easy solution for global users to rapidly screen for male infertility. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  16. Fatigue Behavior of Porous Ti-6Al-4V Made by Laser-Engineered Net Shaping

    PubMed Central

    Bordonaro, Giancarlo G.; Berto, Filippo

    2018-01-01

    The fatigue behavior and fracture mechanisms of additively manufactured Ti-6Al-4V specimens are investigated in this study. Three sets of testing samples were fabricated for the assessment of fatigue life. The first batch of samples was built by using Laser-Engineered Net Shaping (LENS) technology, a Direct Energy Deposition (DED) method. Internal voids and defects were induced in a second batch of samples by changing LENS machine processing parameters. Fatigue performance of these samples is compared to the wrought Ti-6Al-4V samples. The effects of machine-induced porosity are assessed on mechanical properties and results are presented in the form of SN curves for the three sets of samples. Fracture mechanisms are examined by using Scanning Electron Microscopy (SEM) to characterize the morphological characteristics of the failure surface. Different fracture surface morphologies are observed for porous and non-porous specimens due to the combination of head write speed and laser power. Formation of defects such as pores, unmelted regions, and gas entrapments affect the failure mechanisms in porous specimens. Non-porous specimens exhibit fatigue properties comparable with that of the wrought specimens, but porous specimens are found to show a tremendous reduced fatigue strength. PMID:29439510

  17. ALMA observations of lensed Herschel sources: testing the dark matter halo paradigm

    NASA Astrophysics Data System (ADS)

    Amvrosiadis, A.; Eales, S. A.; Negrello, M.; Marchetti, L.; Smith, M. W. L.; Bourne, N.; Clements, D. L.; De Zotti, G.; Dunne, L.; Dye, S.; Furlanetto, C.; Ivison, R. J.; Maddox, S. J.; Valiante, E.; Baes, M.; Baker, A. J.; Cooray, A.; Crawford, S. M.; Frayer, D.; Harris, A.; Michałowski, M. J.; Nayyeri, H.; Oliver, S.; Riechers, D. A.; Serjeant, S.; Vaccari, M.

    2018-04-01

    With the advent of wide-area submillimetre surveys, a large number of high-redshift gravitationally lensed dusty star-forming galaxies have been revealed. Because of the simplicity of the selection criteria for candidate lensed sources in such surveys, identified as those with S500 μm > 100 mJy, uncertainties associated with the modelling of the selection function are expunged. The combination of these attributes makes submillimetre surveys ideal for the study of strong lens statistics. We carried out a pilot study of the lensing statistics of submillimetre-selected sources by making observations with the Atacama Large Millimeter Array (ALMA) of a sample of strongly lensed sources selected from surveys carried out with the Herschel Space Observatory. We attempted to reproduce the distribution of image separations for the lensed sources using a halo mass function taken from a numerical simulation that contains both dark matter and baryons. We used three different density distributions, one based on analytical fits to the haloes formed in the EAGLE simulation and two density distributions [Singular Isothermal Sphere (SIS) and SISSA] that have been used before in lensing studies. We found that we could reproduce the observed distribution with all three density distributions, as long as we imposed an upper mass transition of ˜1013 M⊙ for the SIS and SISSA models, above which we assumed that the density distribution could be represented by a Navarro-Frenk-White profile. We show that we would need a sample of ˜500 lensed sources to distinguish between the density distributions, which is practical given the predicted number of lensed sources in the Herschel surveys.

  18. OGLE-2013-BLG-1761Lb: A Massive Planet around an M/K Dwarf

    NASA Astrophysics Data System (ADS)

    Hirao, Y.; Udalski, A.; Sumi, T.; Bennett, D. P.; Koshimoto, N.; Bond, I. A.; Rattenbury, N. J.; Suzuki, D.; and; Abe, F.; Asakura, Y.; Barry, R. K.; Bhattacharya, A.; Donachie, M.; Evans, P.; Fukui, A.; Itow, Y.; Li, M. C. A.; Ling, C. H.; Masuda, K.; Matsubara, Y.; Matsuo, T.; Muraki, Y.; Nagakane, M.; Ohnishi, K.; Ranc, C.; Saito, To.; Sharan, A.; Shibai, H.; Sullivan, D. J.; Tristram, P. J.; Yamada, T.; Yamada, T.; Yonehara, A.; MOA Collaboration; Poleski, R.; Skowron, J.; Mróz, P.; Szymański, M. K.; Kozłowski, S.; Pietrukowicz, P.; Soszyński, I.; Wyrzykowski, Ł.; Ulaczyk, K.; OGLE Collaboration

    2017-07-01

    We report the discovery and the analysis of the planetary microlensing event, OGLE-2013-BLG-1761. There are some degenerate solutions in this event because the planetary anomaly is only sparsely sampled. However, the detailed light-curve analysis ruled out all stellar binary models and shows the lens to be a planetary system. There is the so-called close/wide degeneracy in the solutions with the planet/host mass ratio of q ˜ (7.0 ± 2.0) × 10-3 and q ˜ (8.1 ± 2.6) × 10-3 with the projected separation in Einstein radius units of s = 0.95 (close) and s = 1.18 (wide), respectively. The microlens parallax effect is not detected, but the finite source effect is detected. Our Bayesian analysis indicates that the lens system is located DL=6.9-1.2+1.0 kpc away from us and the host star is an M/K dwarf with a mass of ML=0.33-0.19+0.32 M⊙ orbited by a super-Jupiter mass planet with a mass of mP=2.7-1.5+2.5 MJup at the projected separation of a\\perp=1.8-0.5+0.5 au. The preference of the large lens distance in the Bayesian analysis is due to the relatively large observed source star radius. The distance and other physical parameters may be constrained by the future high-resolution imaging by large ground telescopes or HST. If the estimated lens distance is correct, then this planet provides another sample for testing the claimed deficit of planets in the Galactic bulge.

  19. OGLE-2013-BLG-1761Lb: A Massive Planet around an MK Dwarf

    NASA Technical Reports Server (NTRS)

    Hirao, Y.; Udalski, A.; Sumi, T.; Bennett, D. P.; Koshimoto, N.; Bond, I. A.; Rattenbury, N. J.; Suzuki, D.; Abe, F.; Asakura, Y.; hide

    2017-01-01

    We report the discovery and the analysis of the planetary microlensing event, OGLE-2013-BLG-1761. There are some degenerate solutions in this event because the planetary anomaly is only sparsely sampled. However, the detailed light curve analysis ruled out all stellar binary models and shows the lens to be a planetary system. There is the so-called close wide degeneracy in the solutions with the planet host mass ratio of q approx.(7.0+/-2.0) x 10(exp -3) and q approx.(8.1+/-2.6) x 10(exp -3) with the projected separation in Einstein radius units of s = 0.95 (close) and s = 1.18(wide), respectively. The microlens parallax effect is not detected, but the finite source effect is detected. Our Bayesian analysis indicates that the lens system is located -D(sub L) = 6.9(+ 1.0 -1.2)kpc away from us and the host star is an M/K dwarf with amass of M(sub L) = 0.33(+ 0.32- 1.9)Stellar Mass orbited by a super-Jupiter mass planet with a mass of m(sub p) = 2.7(+ 2.5 - 1.5) M(sub Jup) at the projected separation of a(sub l) = 1.8(+ 0.5 -0.5)au. The preference of the large lens distance in the Bayesian analysis is due to the relatively large observed source star radius. The distance and other physical parameters may be constrained by the future high-resolution imaging by large ground telescopes or HST. If the estimated lens distance is correct, then this planet provides another sample for testing the claimed deficit of planets in the Galactic bulge.

  20. Optical compensation for night myopia based on dark focus and CA/C ratio.

    PubMed

    Kotulak, J C; Morse, S E; Rabin, J C

    1995-07-01

    To determine whether individual differences in dark focus and convergence accommodation to convergence (CA/C) ratio can be used to prescribe the best optical correction for night myopia. The best correction for night myopia was obtained by measuring visual acuity and contrast sensitivity across a range of lens powers and luminances. Dark focus was measured with an infrared optometer, and CA/C ratio was measured with an infrared optometer and eyetracker. Only young subjects were used (mean age = 25.4 years). Optimal lens power was significantly correlated with dark focus, regardless of CA/C ratio. However, the slope of the regression line relating lens power to dark focus was steeper for subjects with CA/C ratios less than 0.4 diopters/meter angle (D/MA, n = 7) than for subjects with CA/C ratios greater than 0.4 D/MA (n = 9). The mean CA/C ratio for the entire sample (n = 16) was 0.59 D/MA. The mean optimal lens power and dark focus were -0.79 and 0.74 D, respectively, for the low CA/C group, and -0.60 and 0.91 D, respectively, for the high CA/C group. Visual performance in night myopia can be optimized by taking into account intersubject differences in dark focus and CA/C ratio. Best visual performance was found with a lens roughly equaling the full dark focus for subjects with low CA/C ratios and half the dark focus for subjects with high CA/C ratios.

  1. Presence of Acanthamoeba in the ocular surface in a Spanish population of contact lens wearers.

    PubMed

    Rodríguez-Martín, Javier; Rocha-Cabrera, Pedro; Reyes-Batlle, María; López-Arencibia, Atteneri; Sifaoui, Ines; Rizo-Liendo, Aitor; Bethencourt-Estrella, Carlos J; Piñero, José E; Lorenzo-Morales, Jacob

    2018-06-26

    Pathogenic strains of Acanthamoeba are causative agents of a sight-threatening infection of the cornea known as Acanthamoeba keratitis (AK) which mainly affects contact lens wearers and it is commonly related to poor hygiene of contact lenses and their cases. Moreover, treatment of AK is complex due to the existence of a highly resistant cyst stage and if not diagnosed early has poor prognosis, leading to blindness and/or keratoplasty. Even though AK is increasing worldwide as well as awareness among patients and clinicians, it is still a poorly studied pathogen. Additionally, a remaining question to be answered is whether these opportunistic pathogens are present in the ocular surface of healthy contact lens wearers since they are the main group at risk.In order to carry out this study, sterile Schirmer strip tests were collected from a group of individuals all of them contact lens wearers who were attending a local ophthalmology clinic in Tenerife, Canary Islands, Spain. The collected samples (100 eyes of 50 patients) were cultured in 2% Non-Nutrient Agar (NNA) plates and positive plates (16) were then cultured in axenic conditions for further analyses. Molecular analysis classified all isolated strains belonged to Acanthamoeba genotype T4 and osmotolerance and thermotolerance assays revealed that all strains were potentially pathogenic. In conclusion, the ocular surface of contact lens wearers included in this study was colonized by potentially pathogenic strains of Acanthamoeba and should be considered as a risk for AK infection in this region and worldwide.

  2. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology.

    PubMed

    Vano, E; Sanchez, R M; Fernandez, J M

    2015-07-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. 3D+time acquisitions of 3D cell culture by means of lens-free tomographic microscopy

    NASA Astrophysics Data System (ADS)

    Berdeu, Anthony; Laperrousaz, Bastien; Bordy, Thomas; Morales, S.; Gidrol, Xavier; Picollet-D'hahan, Nathalie; Allier, Cédric

    2018-02-01

    We propose a three-dimensional (3D) imaging platform based on lens-free microscopy to perform multi-angle acquisitions on 3D cell cultures embedded in extracellular matrix (ECM). We developed algorithms based on the Fourier diffraction theorem to perform fully 3D reconstructions of biological samples and we adapted the lens-free microscope to incubator conditions. Here we demonstrate for the first time, 3D+time lens-free acquisitions of 3D cell culture over 8 days directly into the incubator. The 3D reconstructed volume is as large as 5 mm3 and provides a unique way to observe in the same 3D cell culture experiment multiple cell migration strategies. Namely, in a 3D cell culture of prostate epithelial cells embedded within a Matrigel® matrix, we are able to distinguish single cell 'leaders', migration of cell clusters, migration of large aggregates of cells, and also close-gap and large-scale branching. In addition, we observe long-scale 3D deformations of the ECM that modify the geometry of the 3D cell culture. Interestingly, we also observed the opposite, i.e. we found that large aggregates of cells may deform the ECM by generating traction forces over very long distances. In sum we put forward a novel 3D lens-free microscopy tomographic technique to study the single and collective cell migrations, the cell-to-cell interactions and the cell-to-matrix interactions.

  4. Spectrophotometric probe

    DOEpatents

    Prather, W.S.; O'Rourke, P.E.

    1994-08-02

    A support structure is described bearing at least one probe for making spectrophotometric measurements of a fluid using a source of light and a spectrophotometer. The probe includes a housing with two optical fibers and a planoconvex lens. A sleeve bearing a mirror surrounds the housing. The lens is separated from the mirror by a fixed distance, defining an interior space for receiving a volume of the fluid sample. A plurality of throughholes extending through the sleeve communicate between the sample volume and the exterior of the probe, all but one hole bearing a screen. A protective jacket surrounds the probe. A hollow conduit bearing a tube is formed in the wall of the probe for venting any air in the interior space when fluid enters. The probe is held at an acute angle so the optic fibers carrying the light to and from the probe are not bent severely on emergence from the probe. 3 figs.

  5. Spectrophotometric probe

    DOEpatents

    Prather, William S.; O'Rourke, Patrick E.

    1994-01-01

    A support structure bearing at least one probe for making spectrophotometric measurements of a fluid using a source of light and a spectrophotometer. The probe includes a housing with two optical fibers and a planoconvex lens. A sleeve bearing a mirror surrounds the housing. The lens is separated from the mirror by a fixed distance, defining an interior space for receiving a volume of the fluid sample. A plurality of throughholes extending through the sleeve communicate between the sample volume and the exterior of the probe, all but one hole bearing a screen. A protective jacket surrounds the probe. A hollow conduit bearing a tube is formed in the wall of the probe for venting any air in the interior space when fluid enters. The probe is held at an acute angle so the optic fibers carrying the light to and from the probe are not bent severely on emergence from the probe.

  6. Spatially sculpted laser scissors for study of DNA damage and repair

    NASA Astrophysics Data System (ADS)

    Stephens, Jared; Mohanty, Samarendra K.; Genc, Suzanne; Kong, Xiangduo; Yokomori, Kyoko; Berns, Michael W.

    2009-09-01

    We present a simple and efficient method for controlled linear induction of DNA damage in live cells. By passing a pulsed laser beam through a cylindrical lens prior to expansion, an elongated elliptical beam profile is created with the ability to expose controlled linear patterns while keeping the beam and the sample stationary. The length and orientation of the beam at the sample plane were reliably controlled by an adjustable aperture and rotation of the cylindrical lens, respectively. Localized immunostaining by the DNA double strand break (DSB) markers phosphorylated H2AX (γH2AX) and Nbs1 in the nuclei of HeLa cells exposed to the ``line scissors'' was shown via confocal imaging. The line scissors method proved more efficient than the scanning mirror and scanning stage methods at induction of DNA DSB damage with the added benefit of having a greater potential for high throughput applications.

  7. Astigmatism of the Ex Vivo Human Lens: Surface and Gradient Refractive Index Age-Dependent Contributions.

    PubMed

    Birkenfeld, Judith; de Castro, Alberto; Marcos, Susana

    2015-08-01

    We estimated the contribution of the gradient refractive index (GRIN) and lens surfaces to lens astigmatism and lens astigmatic angle as a function of age in human donor lenses. Human lenses were imaged, ex vivo, with 3D-spectral optical coherence tomography (OCT) and their back focal length was measured using laser ray tracing. The contribution of lens surfaces and GRIN to lens astigmatism were evaluated by computational ray tracing on the GRIN lens and a homogenous equivalent index lens. Astigmatism magnitude and relative astigmatic angle of and between lens surfaces, GRIN lens, and lens with homogeneous refractive index were evaluated, and all results were correlated with age. The magnitude of astigmatism in the anterior lens surface decreased with age (slope = -0.005 diopters [D]/y; r = 0.397, P = 0.018). Posterior surface astigmatism and lens astigmatism were not age-dependent. Presence of GRIN did not alter significantly the magnitude or axis of the lens astigmatism. The astigmatism of GRIN lens and lens with homogeneous refractive index correlated with anterior lens surface astigmatism (GRIN, P = 3.9E - 6, r = 0.693; equivalent refractive index lens, P = 4.1E - 4, r = 0.565). The astigmatic angle of posterior surface, GRIN lens, and homogeneous refractive index lens did not change significantly with age. The axis of lens astigmatism is close to the astigmatic axis of the anterior lens surface. Age-related changes in lens astigmatism appear to be related to changes in the anterior lens astigmatism. The influence of the GRIN on lens astigmatism and the astigmatic axis is minor.

  8. Non-invasive measurements of the dynamic changes in the ciliary muscle, crystalline lens morphology, and anterior chamber during accommodation with a high-resolution OCT.

    PubMed

    Esteve-Taboada, José J; Domínguez-Vicent, Alberto; Monsálvez-Romín, Daniel; Del Águila-Carrasco, Antonio J; Montés-Micó, Robert

    2017-07-01

    The purpose of the study was to assess non-invasively the changes in the anterior chamber eye, crystalline lens morphology, and ciliary muscle during accommodation by means of an anterior chamber optical coherence tomographer (OCT), and correlate them with vergence. Twenty-five eyes of twenty-five healthy subjects, whose mean age was 29.9±7.1 years, were included and measured with an anterior chamber OCT. The central corneal thickness (CCT), anterior chamber depth (ACD), anterior crystalline lens radius of curvature (ALRC), crystalline lens thickness (CLT), and ciliary muscle area (CMA) were measured for each participant at 0, -1, -2, and -3 D of target vergence. A linear model was used to assess the correlation of each eye parameter with the vergence demand. The mean CCT showed no change for all the accommodative stimuli. The mean ACD and ALRC decreased with the vergence, about 4.5 and 30 % at -3 D, respectively. On the contrary, the CLT and CMA showed an opposite tendency, where the mean CLT was increased by 4.0 % and the mean CMA was done by 26% at -3 D. Statistical significant differences (p < 0.001) were obtained among all vergences for each eye metric, except for the CCT (p = 0.76). The ACD and ALRC decreased about 2 and 10 % per dioptre of accommodation, respectively; whereas the CLT and CMA increased about 2 and 9 %, respectively. These results add knowledge regarding the understanding of accommodation and give new perspectives for biomechanics and biometry.

  9. Visual acuity, endothelial cell density and polymegathism after iris-fixated lens implantation.

    PubMed

    Nassiri, Nader; Ghorbanhosseini, Saeedeh; Jafarzadehpur, Ebrahim; Kavousnezhad, Sara; Nassiri, Nariman; Sheibani, Kourosh

    2018-01-01

    The purpose of this study was to evaluate the visual acuity as well as endothelial cell density (ECD) and polymegathism after iris-fixated lens (Artiflex ® AC 401) implantation for correction of moderate to high myopia. In this retrospective cross-sectional study, 55 eyes from 29 patients undergoing iris-fixated lens implantation for correction of myopia (-5.00 to -15.00 D) from 2007 to 2014 were evaluated. Uncorrected visual acuity, best spectacle-corrected visual acuity, refraction, ECD and polymegathism (coefficient of variation [CV] in the sizes of endothelial cells) were measured preoperatively and 6 months postoperatively. In the sixth month of follow-up, the uncorrected vision acuity was 20/25 or better in 81.5% of the eyes. The best-corrected visual acuity was 20/30 or better in 96.3% of the eyes, and more than 92% of the eyes had a refraction score of ±1 D from the target refraction. The mean corneal ECD of patients before surgery was 2,803±339 cells/mm 2 , which changed to 2,744±369 cells/mm 2 six months after surgery ( p =0.142). CV in the sizes of endothelial cells before the surgery was 25.7%±7.1% and six months after surgery it was 25.9%±5.4% ( p =0.857). Artiflex iris-fixated lens implantation is a suitable and predictable method for correction of moderate to high myopia. There was no statistically significant change in ECD and polymegathism (CV in the sizes of endothelial cells) after 6 months of follow-up.

  10. Delayed progression of diabetic cataractogenesis and retinopathy by Litchi chinensis in STZ-induced diabetic rats.

    PubMed

    Kilari, Eswar Kumar; Putta, Swathi

    2017-03-01

    The study was carried out to evaluate the effect of the aqueous fruit pericarp extract of Litchi chinensis (APLC) on parameters which leads to diabetic cataractogenesis and retinopathy in the streptozotocin-induced diabetic rats. The objective of the study is to evaluate the APLC for in vivo antioxidant activity and its role in inhibiting the polyol pathway and formation of advanced glycation end products (AGEs). The diabetic animals were treated with L. chinensis for a period of 12 weeks. At the end of 12 weeks, the animals were killed and the biochemical pathways involved in the pathogenesis of cataract such as oxidative stress by protein content, superoxide dismutase (SOD), catalase (CAT), reduced glutathione (GSH), and polyolpathway by aldose reductase (AR) in lens homogenates, alterations in protein carbonyl content (PCO) and AGEs in both serum and lens the APLC-treated diabetic rats were compared against diabetic control rats. Cataract progression due to hyperglycemia was monitored by slit lamp bio microscope and classified into four stages. Fundoscope test and retinal histopathology were done for assessing retinopathy. Statistically significant reduction in glucose, and elevation of protein content, SOD, CAT, and GSH levels and decreased levels of AR and PCO in lens homogenate and significant reduction in AGEs serum and lens homogenate were observed. Slit lamp examination, fundoscope, and histopathology showed improvement in retinal changes in APLC-treated rats compared to diabetic control animals. The treatment with APLC found to delay the progression of diabetic cataractogenesis and retinopathy, which might be due to its antioxidant activity, because of the presence of active phytochemicals in APLC.

  11. In vitro optical quality of monofocal aspheric toric intraocular lenses: effect of cylindrical power.

    PubMed

    Ferrer-Blasco, Teresa; Domínguez-Vicent, Alberto; García-Lázaro, Santiago; Diez, María Amparo; Alfonso, José F; Esteve-Taboada, José J

    2018-06-01

    To assess the in vitro optical quality of monofocal aspheric toric intraocular lenses (IOLs) as a function of the cylindrical power. The in vitro optical quality of the AcrySof IQ Toric IOLs SN6AT2, SN6AT3, SN6AT4, SN6AT5 and SN6AT6 (Alcon Laboratories Inc., Forth Worth, TX, USA) was assessed with an instrument conceived for measuring Zernike's coefficients at 3.0- and 5.0-mm apertures. As a reference, the aspheric monofocal lens AcrySof IQ Aspheric SN60WF (Alcon Laboratories Inc., Forth Worth, TX, USA) was also measured. The area of visibility and cut-off frequency were used to describe the modulation transfer function (MTF) of each lens; meanwhile, the light in the bucket and the diameter of a circular area centred on the point-spread function (PSF) peak that captures 50% of the light energy were used to describe the PSF of each lens. Finally, an image simulation was computed from the Zernike values with reference purposes. Small differences were found on the metrics used for describing the MTF and PSF of the lenses at both tested apertures, but these were not statistically significant (p > 0.05). Furthermore, the image simulation showed that these differences would not have clinical relevance at all. The optical performance of the AcrySof IQ toric IOLs in terms of MTF and PSF is good and seems to be independent of the cylindrical power and similar to a non-toric aspheric lens.

  12. Detachment of trophozoites of Acanthamoeba species from soft contact lenses with BEN22 detergent, BioSoak, and Renu multi-purpose solutions.

    PubMed

    Raali, E; Vaahtoranta-Lehtonen, H H; Lehtonen, O P

    2001-07-01

    BEN22 detergent was studied for its ability to detach Acanthamoeba from soft contact lenses without mechanical cleaning or separate cleaning agents. Trophozoites of Acanthamoeba castellanii and A. polyphaga were adhered onto nonionic, high water content soft contact lenses. The lenses were immersed for 2 hours in contact lens care solutions and the remaining trophozoites were counted microscopically. The counts were compared to the counts on the same lens before treatment. BEN22 (50:50 mixture of L-alpha-L-rhamnopyranosyl-beta-hydroxydecanoyl-beta-hydroxydecanoate and 2-O-alpha-L-rhamnopyranosyl-alpha-L-rhamnopyranosyl-beta-hydroxydecanoyl-beta-hydroxydecanoate) (Kassell Industries, Inc., Wisconsin Dells, WI) in a concentration of 0.05% detached the trophozoites to a statistically significant greater extent than saline, but commercial ReNu Multi-Purpose Solution (Bausch & Lomb, Italy) and BioSoak (Finnsusp Ltd., Finland) did so as well. ReNu Multi-Purpose Solution was more effective than 0.005% BEN22 in detaching the trophozoites of both of the Acanthamoeba strains. After the 2 hour immersion period, a maximum of 97% of the initial trophozoites were detached. The variation between individual lenses was significantly greater than that within the different areas of one lens. BEN22 had no reliable detaching effect on Acanthamoeba. The variation between lenses was great, and the rate of detachment was low with all the agents tested indicating that immersion and rinsing in the solutions tested cannot be considered as a safe substitute for proper disinfection against Acanthamoeba in contact lens care.

  13. The eye lens: age-related trends and individual variations in refractive index and shape parameters.

    PubMed

    Pierscionek, Barbara; Bahrami, Mehdi; Hoshino, Masato; Uesugi, Kentaro; Regini, Justyn; Yagi, Naoto

    2015-10-13

    The eye lens grows throughout life by cell accrual on its surface and can change shape to adjust the focussing power of the eye. Varying concentrations of proteins in successive cell layers create a refractive index gradient. The continued growth of the lens and age-related changes in proteins render it less able to alter shape with loss of capacity by the end of the sixth decade of life. Growth and protein ageing alter the refractive index but as accurate measurement of this parameter is difficult, the nature of such alterations remains uncertain. The most accurate method to date for measuring refractive index in intact lenses has been developed at the SPring-8 synchrotron. The technique, based on Talbot interferometry, has an X-ray source and was used to measure refractive index in sixty-six human lenses, aged from 16 to 91 years. Height and width were measured for forty-five lenses. Refractive index contours show decentration in some older lenses but individual variations mask age-related trends. Refractive index profiles along the optic axis have relatively flat central sections with distinct micro-fluctuations and a steep gradient in the cortex but do not exhibit an age-related trend. The refractive index profiles in the equatorial aspect show statistical significance with age, particularly for lenses below the age of sixty that had capacity to alter shape in vivo. The maximum refractive index in the lens centre decreases slightly with age with considerable scatter in the data and there are age-related variations in sagittal thickness and equatorial height.

  14. The eye lens: age-related trends and individual variations in refractive index and shape parameters

    PubMed Central

    Pierscionek, Barbara; Bahrami, Mehdi; Hoshino, Masato; Uesugi, Kentaro; Regini, Justyn; Yagi, Naoto

    2015-01-01

    The eye lens grows throughout life by cell accrual on its surface and can change shape to adjust the focussing power of the eye. Varying concentrations of proteins in successive cell layers create a refractive index gradient. The continued growth of the lens and age-related changes in proteins render it less able to alter shape with loss of capacity by the end of the sixth decade of life. Growth and protein ageing alter the refractive index but as accurate measurement of this parameter is difficult, the nature of such alterations remains uncertain. The most accurate method to date for measuring refractive index in intact lenses has been developed at the SPring-8 synchrotron. The technique, based on Talbot interferometry, has an X-ray source and was used to measure refractive index in sixty-six human lenses, aged from 16 to 91 years. Height and width were measured for forty-five lenses. Refractive index contours show decentration in some older lenses but individual variations mask age-related trends. Refractive index profiles along the optic axis have relatively flat central sections with distinct micro-fluctuations and a steep gradient in the cortex but do not exhibit an age-related trend. The refractive index profiles in the equatorial aspect show statistical significance with age, particularly for lenses below the age of sixty that had capacity to alter shape in vivo. The maximum refractive index in the lens centre decreases slightly with age with considerable scatter in the data and there are age-related variations in sagittal thickness and equatorial height. PMID:26416418

  15. H0LiCOW - III. Quantifying the effect of mass along the line of sight to the gravitational lens HE 0435-1223 through weighted galaxy counts★

    NASA Astrophysics Data System (ADS)

    Rusu, Cristian E.; Fassnacht, Christopher D.; Sluse, Dominique; Hilbert, Stefan; Wong, Kenneth C.; Huang, Kuang-Han; Suyu, Sherry H.; Collett, Thomas E.; Marshall, Philip J.; Treu, Tommaso; Koopmans, Leon V. E.

    2017-06-01

    Based on spectroscopy and multiband wide-field observations of the gravitationally lensed quasar HE 0435-1223, we determine the probability distribution function of the external convergence κext for this system. We measure the under/overdensity of the line of sight towards the lens system and compare it to the average line of sight throughout the Universe, determined by using the CFHTLenS (The Canada France Hawaii Lensing Survey) as a control field. Aiming to constrain κext as tightly as possible, we determine under/overdensities using various combinations of relevant informative weighting schemes for the galaxy counts, such as projected distance to the lens, redshift and stellar mass. We then convert the measured under/overdensities into a κext distribution, using ray-tracing through the Millennium Simulation. We explore several limiting magnitudes and apertures, and account for systematic and statistical uncertainties relevant to the quality of the observational data, which we further test through simulations. Our most robust estimate of κext has a median value κ^med_ext = 0.004 and a standard deviation σκ = 0.025. The measured σκ corresponds to 2.5 per cent relative uncertainty on the time delay distance, and hence the Hubble constant H0 inferred from this system. The median κ^med_ext value varies by ˜0.005 with the adopted aperture radius, limiting magnitude and weighting scheme, as long as the latter incorporates galaxy number counts, the projected distance to the main lens and a prior on the external shear obtained from mass modelling. This corresponds to just ˜0.5 per cent systematic impact on H0. The availability of a well-constrained κext makes HE 0435-1223 a valuable system for measuring cosmological parameters using strong gravitational lens time delays.

  16. [Killing effects of PWZL plasmid-mediated double suicide gene on human lens epithelium cells].

    PubMed

    Yan, Xiao-ran; Wu, Hong; Yu, Hai-tao; Wang, Xiu; Zhang, Yu

    2008-04-01

    To investigate the killing efficiency of PWZL plasmid-mediated herpes simplex virus-thymidine kinase (TK) and E. coli cytosine deaminase (CD) on human lens epithelium cells followed by the treatment of prodrugs. PWZL plasmid was used as a vehicle, to transduce double suicide genes into the human lens epithelium in vitro, then the cells were treated with fluorocytosine (5-FC) and/or ganciclovir (GCV) at different concentrations. The cell growth of the lens epithelium cells was observed by light microscope. MTT analysis was used to estimate the cell survival rate and the bystander effect was analyzed simultaneously. The significance of difference between each group was treated by statistical tests. The CD and TK gene could be joined into PWZL plasmid successfully, and did not have any special effect on normal cells. There was no significant difference in cell viability between CD-TK transfected cells and control cells. Cell viability in cells treated with prodrugs was decreased in a time-dependent manner. At the end of the experiment, cell viability was lowest in GCV 10 mg/L +5-FC 60 mg/L group, GCV 10 mg/L + 5-FC 100 mg/L group and GCV 100 mg/L + 5-FC 100 mg/L group. There were no significant differences between these three groups (X2 = 1.25 , P > 0.01). Analysis of bystander effect indicated that the cell viability in GCV 100 mg/L + 5-FC 100 mg/L group and GCV 10 mg/L +5-FC 60 mg/L group was significantly lower than that in the controls (t = 10.26, 13.16; P < 0.01). PWZL plasmid can transfect the CD and TK genes into lens epithelium cells successfully and efficiently. CD and TK genes can be expressed steadily. Transfection of double suicide gene reduces the dosage of prodrugs required for killing cells. The combination of 5-FC with GCV shows the greatest killing effect and also has the bystander effect.

  17. Short-term Effect of Scleral Lens on the Dry Eye Biomarkers in Keratoconus.

    PubMed

    Carracedo, Gonzalo; Blanco, Maria Serramito; Martin-Gil, Alba; Zicheng, Wang; Alvarez, Jesús Carballo; Pintor, Jesús

    2016-02-01

    To evaluate the most important signs of dry eye, such as osmolarity, inflammation, and diadenosine tetraphosphate (Ap(4)A) concentration before and after wearing scleral lenses for 8 h in keratoconus patients. A pilot, experimental, short-term study involved 26 keratoconus patients (average age, 36.95 ± 8.95 years). They voluntarily enrolled in the study at the Optometry Clinic of the Faculty of Optics and Optometry in the University Complutense of Madrid. They were divided into two groups: patients with intrastromal corneal ring, the ICRS group, and patients without ICRS, the keratoconus (KC) group. Ocular Surface Disease Index questionnaire, the Schirmer test without anesthesia, tear break-up time, matrix metalloproteinase 9 (MMP-9) concentration, osmolarity, and Ap4A concentration were evaluated before and after wearing a scleral lens for 8 h. The patients wore the scleral lenses from 6 to 9 h, with a mean of 7.59 ± 0.73 h. The mean scleral lens sag for all patients was 4310 ± 166.31 μm, ranging from 4200 μm to 4800 μm. No significant changes in the Schirmer test and tear break-up time were found for either group. Ocular Surface Disease Index scores were statistically lower after wearing scleral lenses for both groups (p < 0.05). A significantly lower osmolarity and a significant rise of MMP-9 concentration after wearing scleral lenses were found in both groups (p < 0.05). Diadenosine tetraphosphate concentration was lower after wearing the scleral lens in the KC group (p < 0.05) but no significant difference was found for the ICRS group (p > 0.05). Short-term scleral lens wearing improves the symptomatology and some signs of dry eye, such as osmolarity and Ap4A concentration. The increase of MMP-9 concentration could be caused by tear film stagnation and use of preserved saline.

  18. Viewing health expenditures, payment and coping mechanisms with an equity lens in Nigeria

    PubMed Central

    2013-01-01

    Background This paper examines socio-economic and geographic differences in payment and payment coping mechanisms for health services in southeast Nigeria. It shows the extent to which the poor and rural dwellers disproportionally bear the burden of health care costs and offers policy recommendations for improvements. Methods Questionnaires were used to collect data from 3071 randomly selected households in six communities in southeast Nigeria using a four week recall. The sample was divided into quintiles (Q1-Q5) using a socio-economic status (SES) index as well as into geographic groups (rural, peri-urban and urban). Tabulations and logistic regression were used to determine the relationships between payment and payment coping mechanisms and key independent variables. Q1/Q5 and rural/urban ratios were the measures of equity. Results Most of the respondents used out-of-pocket spending (OOPS) and own money to pay for healthcare. There was statistically significant geographic differences in the use of own money to pay for health services indicating more use among rural dwellers. Logistic regression showed statistically significant geographic differences in the use of both OOPS and own money when controlling for the effects of potential cofounders. Conclusions This study shows statistically significant geographic differences in the use of OOPS and own money to pay for health services. Though the SES differences were not statistically significant, they showed high equity ratios indicating more use among poor and rural dwellers. The high expenditure incurred on drugs alone highlights the need for expediting pro-poor interventions like exemptions and waivers aimed at improving access to health care for the vulnerable poor and rural dwellers. PMID:23497246

  19. The effect of protein-coated contact lenses on the adhesion and viability of gram negative bacteria.

    PubMed

    Williams, Timothy J; Schneider, Rene P; Willcox, Mark D P

    2003-10-01

    Gram negative bacterial adhesion to contact lenses can cause adverse responses. During contact lens wear, components of the tear film adsorb to the contact lens. This study aimed to investigate the effect of this conditioning film on the viability of bacteria. Bacteria adhered to contact lenses which were either unworn, worn for daily-, extended- or overnight-wear or coated with lactoferrin or lysozyme. Numbers of viable and total cells were estimated. The number of viable attached cells was found to be significantly lower than the total number of cells on worn (50% for strain Paer1 on daily-wear lenses) or lactoferrin-coated lenses (56% for strain Paer1). Lysozyme-coated lenses no statistically significant effect on adhesion. The conditioning film gained through wear may not inhibit bacterial adhesion, but may act adversely upon those bacteria that succeed in attaching.

  20. Single Particle Differentiation through 2D Optical Fiber Trapping and Back-Scattered Signal Statistical Analysis: An Exploratory Approach

    PubMed Central

    Ribeiro, Rita S. R.; Cunha, João P. S.; Rosa, Carla C.; Jorge, Pedro A. S.

    2018-01-01

    Recent trends on microbiology point out the urge to develop optical micro-tools with multifunctionalities such as simultaneous manipulation and sensing. Considering that miniaturization has been recognized as one of the most important paradigms of emerging sensing biotechnologies, optical fiber tools, including Optical Fiber Tweezers (OFTs), are suitable candidates for developing multifunctional small sensors for Medicine and Biology. OFTs are flexible and versatile optotools based on fibers with one extremity patterned to form a micro-lens. These are able to focus laser beams and exert forces onto microparticles strong enough (piconewtons) to trap and manipulate them. In this paper, through an exploratory analysis of a 45 features set, including time and frequency-domain parameters of the back-scattered signal of particles trapped by a polymeric lens, we created a novel single feature able to differentiate synthetic particles (PMMA and Polystyrene) from living yeasts cells. This single statistical feature can be useful for the development of label-free hybrid optical fiber sensors with applications in infectious diseases detection or cells sorting. It can also contribute, by revealing the most significant information that can be extracted from the scattered signal, to the development of a simpler method for particles characterization (in terms of composition, heterogeneity degree) than existent technologies. PMID:29495502

  1. Single Particle Differentiation through 2D Optical Fiber Trapping and Back-Scattered Signal Statistical Analysis: An Exploratory Approach.

    PubMed

    Paiva, Joana S; Ribeiro, Rita S R; Cunha, João P S; Rosa, Carla C; Jorge, Pedro A S

    2018-02-27

    Recent trends on microbiology point out the urge to develop optical micro-tools with multifunctionalities such as simultaneous manipulation and sensing. Considering that miniaturization has been recognized as one of the most important paradigms of emerging sensing biotechnologies, optical fiber tools, including Optical Fiber Tweezers (OFTs), are suitable candidates for developing multifunctional small sensors for Medicine and Biology. OFTs are flexible and versatile optotools based on fibers with one extremity patterned to form a micro-lens. These are able to focus laser beams and exert forces onto microparticles strong enough (piconewtons) to trap and manipulate them. In this paper, through an exploratory analysis of a 45 features set, including time and frequency-domain parameters of the back-scattered signal of particles trapped by a polymeric lens, we created a novel single feature able to differentiate synthetic particles (PMMA and Polystyrene) from living yeasts cells. This single statistical feature can be useful for the development of label-free hybrid optical fiber sensors with applications in infectious diseases detection or cells sorting. It can also contribute, by revealing the most significant information that can be extracted from the scattered signal, to the development of a simpler method for particles characterization (in terms of composition, heterogeneity degree) than existent technologies.

  2. Mass density slope of elliptical galaxies from strong lensing and resolved stellar kinematics

    NASA Astrophysics Data System (ADS)

    Lyskova, N.; Churazov, E.; Naab, T.

    2018-04-01

    We discuss constraints on the mass density distribution (parametrized as ρ ∝ r-γ) in early-type galaxies provided by strong lensing and stellar kinematics data. The constraints come from mass measurements at two `pinch' radii. One `pinch' radius r1 = 2.2REinst is defined such that the Einstein (i.e. aperture) mass can be converted into the spherical mass almost independently of the mass-model. Another `pinch' radius r2 = Ropt is chosen so that the dynamical mass, derived from the line-of-sight velocity dispersion, is least sensitive to the anisotropy of stellar orbits. We verified the performance of this approach on a sample of simulated elliptical galaxies and on a sample of 15 SLACS lens galaxies at 0.01 ≤ z ≤ 0.35, which have already been analysed in Barnabè et al. by the self-consistent joint lensing and kinematic code. For massive simulated galaxies, the density slope γ is recovered with an accuracy of ˜13 per cent, unless r1 and r2 happen to be close to each other. For SLACS galaxies, we found good overall agreement with the results of Barnabè et al. with a sample-averaged slope γ = 2.1 ± 0.05. Although the two-pinch-radii approach has larger statistical uncertainties, it is much simpler and uses only few arithmetic operations with directly observable quantities.

  3. Imaging system design for improved information capacity

    NASA Technical Reports Server (NTRS)

    Fales, C. L.; Huck, F. O.; Samms, R. W.

    1984-01-01

    Shannon's theory of information for communication channels is used to assess the performance of line-scan and sensor-array imaging systems and to optimize the design trade-offs involving sensitivity, spatial response, and sampling intervals. Formulations and computational evaluations account for spatial responses typical of line-scan and sensor-array mechanisms, lens diffraction and transmittance shading, defocus blur, and square and hexagonal sampling lattices.

  4. Microfluidic Flow Injection Analysis with Thermal Lens Microscopic Detection for Determination of NGAL

    NASA Astrophysics Data System (ADS)

    Radovanović, Tatjana; Liu, Mingqiang; Likar, Polona; Klemenc, Matjaž; Franko, Mladen

    2015-06-01

    A combined microfluidic flow injection analysis-thermal lens microscopy (FIA-TLM) system was applied for determination of neutrophil gelatinase-associated lipocalin (NGAL)—a biomarker of acute kidney injury. NGAL was determined following a commercial ELISA assay and transfer of the resulting solution into the FIA-TLM system with a 100 m deep microchannel. At an excitation power of 100 mW, the FIA-TLM provided about seven times lower limits of detection (1.5 pg as compared to a conventional ELISA test, and a sample throughput of six samples per minute, which compares favorably with sample throughput of the microtiter plate reader, which reads 96 wells in about 30 min. Comparison of results for NGAL in plasma samples from healthy individuals and for NGAL dynamics in patients undergoing coronary angiography measured with transmission mode spectrometry on a microtiter plate reader and with FIA-TLM showed good agreement. In addition to improved LOD, the high sensitivity of FIA-TLM offers possibilities of a further reduction of the total reaction time of the NGAL ELISA test by sacrificing some of the sensitivity while reducing the duration of individual incubation steps.

  5. Multiplex coherent anti-Stokes Raman scattering microspectroscopy for monitoring molecular structural change in biological samples

    NASA Astrophysics Data System (ADS)

    Ohta, Takayuki; Hashizume, Hiroshi; Takeda, Keigo; Ishikawa, Kenji; Ito, Masafumi; Hori, Masaru

    2014-10-01

    Biological applications employing non-equilibrium plasma processing has been attracted much attention. It is essential to monitor the changes in an intracellular structure of the cell during the plasma exposure. In this study, we have analyzed the molecular structure of biological samples using multiplex coherent anti-Stokes Raman scattering (CARS) microspectroscopy. Two picosecond pulse lasers with fundamental (1064 nm) or the supercontinuum (460-2200 nm) were employed as a pump and Stokes beams of multiplex CARS microspectroscopy, respectively. The pump and the Stokes laser beams were collinearly overlapped and tightly focused into a sample using an objective lens of high numerical aperture. The CARS signal was collected by another microscope objective lens which is placed facing the first one. After passing through a short pass filter, the signal was dispersed by a polychromator, and was detected by a charge-coupled device camera. The sample was sandwiched by a coverslip and a glass bottom dish for the measurements and was placed on a piezo stage. The CARS signals of the quinhydrone crystal at 1655, 1584, 1237 and 1161 cm-1 were assigned to the C-C, C =O stretching, O-H and C-O stretching vibrational modes, respectively.

  6. Water quality determination by photographic analysis. [optical density and water turbidity

    NASA Technical Reports Server (NTRS)

    Klooster, S. A.; Scherz, J. P.

    1973-01-01

    Aerial reconnaissance techniques to extract water quality parameters from aerial photos are reported. The turbidity can be correlated with total suspended solids if the constituent parts of the effluent remain the same and the volumetric flow remains relatively constant. A monochromator is used for the selection of the bandwidths containing the most information. White reflectance panels are used to locate sampling points and eliminate inherent energy changes from lens flare, radial lens fall-off, and changing subject illumination. Misleading information resulting from bottom effects is avoided by the use of Secchi disc readings and proper choice of wavelength for analyzing the photos.

  7. Measurement of nonlinear optical refraction of composite material based on sapphire with silver by Kerr-lens autocorrelation method.

    PubMed

    Yu, Xiang-xiang; Wang, Yu-hua

    2014-01-13

    Silver nanoparticles synthesized in a synthetic sapphire matrix were fabricated by ion implantation using the metal vapor vacuum arc ion source. The optical absorption spectrum of the Ag: Al2O3 composite material has been measured. The analysis of the supercontinuum spectrum displayed the nonlinear refractive property of this kind of sample. Nonlinear optical refraction index was identified at 800 nm excitation using the Kerr-lens autocorrelation (KLAC) technique. The spectrum showed that the material possessed self-defocusing property (n(2) = -1.1 × 10(-15) cm(2)W). The mechanism of nonlinear refraction has been discussed.

  8. Wavefront correction in two-photon microscopy with a multi-actuator adaptive lens.

    PubMed

    Bueno, Juan M; Skorsetz, Martin; Bonora, Stefano; Artal, Pablo

    2018-05-28

    A multi-actuator adaptive lens (AL) was incorporated into a multi-photon (MP) microscope to improve the quality of images of thick samples. Through a hill-climbing procedure the AL corrected for the specimen-induced aberrations enhancing MP images. The final images hardly differed when two different metrics were used, although the sets of Zernike coefficients were not identical. The optimized MP images acquired with the AL were also compared with those obtained with a liquid-crystal-on-silicon spatial light modulator. Results have shown that both devices lead to similar images, which corroborates the usefulness of this AL for MP imaging.

  9. Single-beam thermal lens measurement of thermal diffusivity of engine coolants

    NASA Astrophysics Data System (ADS)

    George, Nibu A.; Thomas, Nibu B.; Chacko, Kavya; T, Neethu V.; Hussain Moidu, Haroon; Piyush, K.; David, Nitheesh M.

    2015-04-01

    Automobile engine coolant liquids are commonly used for efficient heat transfer from the engine to the surroundings. In this work we have investigated the thermal diffusivity of various commonly available engine coolants in Indian automobile market. We have used single beam laser induced thermal lens technique for the measurements. Engine coolants are generally available in concentrated solution form and are recommended to use at specified dilution. We have investigated the samples in the entire recommended concentration range for the use in radiators. While some of the brands show an enhanced thermal diffusivity compared to pure water, others show slight decrease in thermal diffusivity.

  10. Effects of pressure and electrical charge on macromolecular transport across bovine lens basement membrane.

    PubMed

    Ferrell, Nicholas; Cameron, Kathleen O; Groszek, Joseph J; Hofmann, Christina L; Li, Lingyan; Smith, Ross A; Bian, Aihua; Shintani, Ayumi; Zydney, Andrew L; Fissell, William H

    2013-04-02

    Molecular transport through the basement membrane is important for a number of physiological functions, and dysregulation of basement membrane architecture can have serious pathological consequences. The structure-function relationships that govern molecular transport in basement membranes are not fully understood. The basement membrane from the lens capsule of the eye is a collagen IV-rich matrix that can easily be extracted and manipulated in vitro. As such, it provides a convenient model for studying the functional relationships that govern molecular transport in basement membranes. Here we investigate the effects of increased transmembrane pressure and solute electrical charge on the transport properties of the lens basement membrane (LBM) from the bovine eye. Pressure-permeability relationships in LBM transport were governed primarily by changes in diffusive and convective contributions to solute flux and not by pressure-dependent changes in intrinsic membrane properties. The solute electrical charge had a minimal but statistically significant effect on solute transport through the LBM that was opposite of the expected electrokinetic behavior. The observed transport characteristics of the LBM are discussed in the context of established membrane transport modeling and previous work on the effects of pressure and electrical charge in other basement membrane systems. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  11. Wide-field fluorescent microscopy on a cell-phone.

    PubMed

    Zhu, Hongying; Yaglidere, Oguzhan; Su, Ting-Wei; Tseng, Derek; Ozcan, Aydogan

    2011-01-01

    We demonstrate wide-field fluorescent imaging on a cell-phone, using compact and cost-effective optical components that are mechanically attached to the existing camera unit of the cell-phone. Battery powered light-emitting diodes (LEDs) are used to side-pump the sample of interest using butt-coupling. The pump light is guided within the sample cuvette to excite the specimen uniformly. The fluorescent emission from the sample is then imaged with an additional lens that is put in front of the existing lens of the cell-phone camera. Because the excitation occurs through guided waves that propagate perpendicular to the detection path, an inexpensive plastic color filter is sufficient to create the dark-field background needed for fluorescent imaging. The imaging performance of this light-weight platform (~28 grams) is characterized with red and green fluorescent microbeads, achieving an imaging field-of-view of ~81 mm(2) and a spatial resolution of ~10 μm, which is enhanced through digital processing of the captured cell-phone images using compressive sampling based sparse signal recovery. We demonstrate the performance of this cell-phone fluorescent microscope by imaging labeled white-blood cells separated from whole blood samples as well as water-borne pathogenic protozoan parasites such as Giardia Lamblia cysts.

  12. A histopathological study of bulbar conjunctival flaps occurring in 2 contact lens wearers.

    PubMed

    Markoulli, Maria; Francis, Ian C; Yong, Jim; Jalbert, Isabelle; Carnt, Nicole; Cole, Nerida; Papas, Eric

    2011-09-01

    To study the histopathology of paralimbal bulbar conjunctival flaps occurring secondary to soft contact lens wear. Slit-lamp biomicroscopy using sodium fluorescein, cobalt blue light, and a Wratten filter was used to observe the presence, location, and dimensions of bulbar conjunctival flaps presenting in a cohort of contact lens wearers. Two subjects who exhibited such flaps agreed to undergo conjunctival biopsy. Tissue samples, obtained from the region of the flap, and an adjacent unaffected area were processed by standard histopathological methods. In the first subject, analysis of the flap tissue showed even collagen distribution and overall normal histology. The flap of the second subject displayed a mild focal increase in collagen and mild degeneration of collagen, but no increase in elastic tissue. Conjunctival epithelium was normal in both cases. In these 2 subjects, conjunctival flap tissue either was normal or showed only minimal abnormality. There is insufficient evidence for significant pathological change on the time scale of this study.

  13. Tests and evaluation of a variable focus liquid lens for curvature wavefront sensors in astronomy.

    PubMed

    Fuentes-Fernández, Jorge; Cuevas, Salvador; Álvarez-Nuñez, Luis C; Watson, Alan

    2013-10-20

    Curvature wavefront sensors (WFSs), which obtain the wavefront aberrations from two defocused intensity images at each side of the pupil plane, have shown to be highly efficient for astronomical applications. We propose here an alternative defocusing mechanism for curvature sensors, based on an electrowetting-based variable focus liquid lens. Typically, the sampling rates of a WFS for active optics are of the order of 0.01 Hz, and the focus modulation can be done by simply moving the detector back and forth. On the other hand, adaptive optics may require speeds of up to several hundred hertz, and the modulation is then done by using a fast vibrating membrane mirror. We believe variable focus liquid lenses may be able to perform this focus modulation, reducing the overall size of the system and without the need of extra moving parts. We have done a full characterization of the Varioptic Arctic 416 liquid lens, and we have evaluated its potential performance in different curvature configurations.

  14. Improvements In The Calculation Of White Light Modulation Transfer Function (MTF) In Japan Optical Engineering Research Association (JOERA)

    NASA Astrophysics Data System (ADS)

    Minami, Setsuo; Ogawa, Ryota

    1980-09-01

    Consequences of the working project formed in JOERA (JAPAN OPTICAL ENGINEERING RESEARCH ASSOCIATION) from 1976 to 1978 are to be reported. The question, "What is the most reasonable number of mesh divides of entrance pupil to get monochromatic OTF and the most economical sampling method of spectral wavelengths to calculate White Light MTF?" is important in the actual stage of designing to optimize the conflict relationship between numerical accuracy and computing time. We have examined the spectral characteristics of OTF using some typical lenses such as photographic telephoto lens and wide angled retrofocus lens, cleared the structure of the White Light MTF, and found some techniques to get the reasonable numerical results. As a result of trial experiments to get coincidence between measurements and calculat-ions, the standard filter, which should be added to the MTF lens tester and whose spectral transmittance should be installed in the calculation, are proposed.

  15. Mode-mismatched confocal thermal-lens microscope with collimated probe beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cabrera, Humberto, E-mail: hcabrera@ictp.it; Centro Multidisciplinartio de Ciencias, Instituto Venezolano de Investigaciones Científicas; Korte, Dorota

    2015-05-15

    We report a thermal lens microscope (TLM) based on an optimized mode-mismatched configuration. It takes advantage of the coaxial counter propagating tightly focused excitation and collimated probe beams, instead of both focused at the sample, as it is in currently known TLM setups. A simple mathematical model that takes into account the main features of the instrument is presented. The confocal detection scheme and the introduction of highly collimated probe beam allow enhancing the versatility, limit of detection (LOD), and sensitivity of the instrument. The theory is experimentally verified measuring ethanol’s absorption coefficient at 532.8 nm. Additionally, the presented techniquemore » is applied for detection of ultra-trace amounts of Cr(III) in liquid solution. The achieved LOD is 1.3 ppb, which represents 20-fold enhancement compared to transmission mode spectrometric techniques and a 7.5-fold improvement compared to previously reported methods for Cr(III) based on thermal lens effect.« less

  16. Comparison of lens- and fiber-coupled CCD detectors for X-ray computed tomography

    PubMed Central

    Uesugi, K.; Hoshino, M.; Yagi, N.

    2011-01-01

    X-ray imaging detectors with an identical phosphor and a CCD chip but employing lens- and fiber-coupling between them have been compared. These are designed for X-ray imaging experiments, especially computed tomography, at the medium-length beamline at the SPring-8 synchrotron radiation facility. It was found that the transmittance of light to the CCD is about four times higher in the fiber-coupled detector. The uniformity of response in the lens-coupled detector has a global shading of up to 40%, while pixel-to-pixel variation owing to a chicken-wire pattern was dominant in the fiber-coupled detector. Apart from the higher transmittance, the fiber-coupled detector has a few characteristics that require attention when it is used for computed tomography, which are browning of the fiber, discontinuity in the image, image distortion, and dark spots in the chicken-wire pattern. Thus, it is most suitable for high-speed tomography of samples that tend to deform, for example biological and soft materials. PMID:21335908

  17. Quantitative proteomics analysis by iTRAQ in human nuclear cataracts of different ages and normal lens nuclei.

    PubMed

    Zhou, Hai Yan; Yan, Hong; Wang, Li Li; Yan, Wei Jia; Shui, Ying Bo; Beebe, David C

    2015-08-01

    The goal of this study was to quantitatively identify the differentially expressed proteins in nuclear cataracts of different ages and normal lens nuclei in humans. Forty-eight human lens nucleus samples with hardness grades III, IV were obtained during cataract surgery by extracapsular cataract extraction. Seven normal transparent human lens nuclei were obtained from fresh normal cadaver eyes during corneal transplantation surgery. Lens nuclei were divided into seven groups according to age and optic axis: Group A (average age 80.8 ± 1.2 years), Group B (average age 57.0 ± 4.0 years), Group C average age 80.3 ± 4.5 years), Group D (average age 56.9 ± 4.2 years), Group E (average age 78.1 ± 2.5 years), Group F (average age 57.6 ± 3.3 years) and Group G (seven normal transparent human lenses from normal cadaver eyes, average age 34.7 ± 4.2 years). Water-soluble, water-insoluble, and water-insoluble-urea-soluble protein fractions were extracted from samples. The three-part protein fractions from the individual lenses were combined to form the total proteins of each sample. The proteomic profiles of each group were further analyzed using 8-plex iTRAQ labeling combined with 2D-LC-MS/MS. The data were analyzed with the ProteinPilot software for peptide matching, protein identification, and quantification. Differentially expressed proteins were validated by Western blotting. We employed biological and technical replicates and selected the intersection of the two results, which included 80 proteins. Nine proteins were differentially expressed among the 80 proteins identified using proteomic techniques. In age-related nuclear cataracts (ARNC), the expression levels of fatty acid-binding protein and pterin-4-alpha-carbinolamine dehydratase were upregulated, whereas the levels of alpha-crystallin B chain (CRYAB), GSH synthetase, phakinin, gamma-crystallin C, phosphoglycerate kinase 1, betaine-homocysteine S-methyltransferase 1 (BHMT1), and spectrin beta chain were downregulated. These proteins may be associated with abnormal protein aggregation and oxidative stress. GSH synthetase and CRYAB expression levels in the nuclear cataract decreased with age. The mass spectrometric analysis results were consistent with the Western blot validation. The results indicate that CRYAB and GSH synthetase may be involved in ARNC pathogenesis. iTRAQ combined with 2D-LC-MS/MS provides new methods for future studies of pathological mechanisms and protective drug development for ARNC. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Chip-carrier thermal barrier and its impact on lateral thermal lens profile and beam parameter product in high power broad area lasers

    NASA Astrophysics Data System (ADS)

    Rieprich, J.; Winterfeldt, M.; Kernke, R.; Tomm, J. W.; Crump, P.

    2018-03-01

    High power broad area diode lasers with high optical power density in a small focus spot are in strong commercial demand. For this purpose, the beam quality, quantified via the beam parameter product (BPP), has to be improved. Previous studies have shown that the BPP is strongly affected by current-induced heating and the associated thermal lens formed within the laser stripe. However, the chip structure and module-assembly related factors that regulate the size and the shape of the thermal lens are not well known. An experimental infrared thermographic technique is used to quantify the thermal lens profile in diode lasers operating at an emission wavelength of 910 nm, and the results are compared with finite element method simulations. The analysis indicates that the measured thermal profiles can best be explained when a thermal barrier is introduced between the chip and the carrier, which is shown to have a substantial impact on the BPP and the thermal resistance. Comparable results are observed in further measurements of samples from multiple vendors, and the barrier is only observed for junction-down (p-down) mounting, consistent with the barrier being associated with the GaAs-metal transition.

  19. Macular thickness and volume after uncomplicated phacoemulsification surgery evaluated by optical coherence tomography. A one-year follow-up.

    PubMed

    Kecik, Dariusz; Makowiec-Tabernacka, Marta; Golebiewska, Joanna; Moneta-Wielgos, Joanna; Kasprzak, Jan

    2009-01-01

    To evaluate changes in the macular thickness and volume using optical coherence tomography in patients after phacoemulsification and intracapsular implantation of a foldable intraocular lens. The study included 82 patients (37 males and 45 females) after phacoemulsification and intracapsular implantaion of the same type of a foldable intraocular lens, without any other eye disease. Phacoemulsification was performed with an INFINITI machine. In all patients, macular thickness and volume were measured with an optical coherence tomograph (Stratus OCT) using the Fast Macular Thickness Map. The OCT evaluation was performed on days 1, 7, 30 and 90 postoperatively. In 58 patients (71%), it was additionally performed at 12 months after surgery and in 52 patients (63%) the macular parameters in the healthy and operated eyes were compared. A statistically significant increase in the minimal retinal thickness was observed on days 30 (p<0.0005) and 90 (p<0.005) postoperatively compared to post-operative day 1. A statistically significant increase in the foveal volume was seen on days 30 (p<0.00005) and 90 (p<0.0005). A statistically significant increase in the volume of the entire macula was found on days 7, 30 and 90 (p<0.00005). Uncomplicated cataract phacoemulsification is followed by increases in the central retinal thickness, foveal volume and volume of the entire macula on days 30 and 90 and at 12 months postoperatively. Further observation of patients is required to confirm whether the macular parameters will return to their values on day 1 postoperatively and if so, when this will occur.

  20. Lens growth and protein changes in the eastern grey kangaroo

    PubMed Central

    2011-01-01

    Purpose Development in marsupials takes place predominantly ex utero while the young is attached to a nipple in the mother’s pouch, very different from that in other species. This study was undertaken to examine whether this affects lens growth and the production of lens proteins in kangaroos. Methods Fresh lenses were obtained at official culls from eastern gray kangaroos (Macropus giganteus). Wet weights were recorded for all and protein contents were determined for one lens from each animal. Dry weights, after fixation were obtained for 20 lenses. Ages were determined using both molar progression and total lens protein content. Lenses were divided into concentric layers by controlled dissolution using phosphate buffered saline. Samples were taken for determination of protein contents and dry weights, which were then used to determine the age of the layer removed. Soluble crystallin distributions were determined by fractionation of the centrifuged extracts using HPLC-GPC and the polypeptide contents of both soluble and insoluble proteins were assessed by SDS–PAGE. Results Lens growth is continuous from birth throughout adulthood and the increases in wet weight and fixed dry weight can be described with a single logistic growth functions for the whole life span. Three major crystallin classes, α-, β-, and γ-crystallins, were identified in the immature pouch-young animals aged around 60 days after birth. Adult lenses contain, in addition, the taxon-specific μ-crystallin. The proportions of these vary with the age of the lens tissue due to age related insolubilization as well as changes in the synthesis patterns. During early lactation (birth to 190 days), the α-, β-, and γ-crystallins represent 25, 53, and 20% of the total protein, respectively. After the pouch-young first releases the nipple (190 days), there is a rapid decrease in the production of γ-crystallins to around 5% of the total and a corresponding increase in μ-crystallin, from 0.5% to 15%. These changes were complete by the time the animal was fully weaned, around 1.5 years, and the final proportions of the 4 protein classes were maintained for the rest of life. The solubilities of α- and β-crystallins in the center of the lens decreased after age 5 years. Conclusions Kangaroo lens growth is asymptotic, similar to that in most other species, even though most development of the young animal takes place ex utero. Changes in the patterns of lens protein synthesis in the kangaroo are similar to those observed in other species except for the large decrease in γ-crystallin and the matching increase in the marsupial-specific μ-crystallin, during late lactation. PMID:22194649

  1. Clinical evaluation of long-term users of two contact lens care preservative systems.

    PubMed

    Young, Graeme; Keir, Nancy; Hunt, Chris; Woods, Craig A

    2009-03-01

    To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye. Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits. Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having "good" or "excellent" wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments. Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.

  2. A spectroscopic survey of the fields of 28 strong gravitational lenses: The group catalog

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, Michelle L.; Zabludoff, Ann I.; Ammons, S. Mark

    With a large, unique spectroscopic survey in the fields of 28 galaxy-scale strong gravitational lenses, we identify groups of galaxies in the 26 adequately sampled fields. Using a group-finding algorithm, we find 210 groups with at least 5 member galaxies; the median number of members is 8. Our sample spans redshifts of 0.04 ≤ z grp ≤ 0.76 with a median of 0.31, including 174 groups with 0.1 < z grp < 0.6. The groups have radial velocity dispersions of 60 ≤ σ grp ≤ 1200 km s –1 with a median of 350 km s –1. We also discovermore » a supergroup in field B0712+472 at z = 0.29 that consists of three main groups. We recover groups similar to ~85% of those previously reported in these fields within our redshift range of sensitivity and find 187 new groups with at least five members. The properties of our group catalog, specifically, (1) the distribution of σ grp, (2) the fraction of all sample galaxies that are group members, and (3) the fraction of groups with significant substructure, are consistent with those for other catalogs. The distribution of group virial masses agrees well with theoretical expectations. Of the lens galaxies, 12 of 26 (46%) (B1422+231, B1600+434, B2114+022, FBQS J0951+2635, HE0435-1223, HST J14113+5211, MG0751+2716, MGJ1654+1346, PG 1115+080, Q ER 0047-2808, RXJ1131-1231, and WFI J2033-4723) are members of groups with at least five galaxies, and one more (B0712+472) belongs to an additional, visually identified group candidate. Furthermore, there are groups not associated with the lens that still are likely to affect the lens model; in six of 25 (24%) fields (excluding the supergroup), there is at least one massive (σ grp ≥ 500 km s –1) group or group candidate projected within 2' of the lens.« less

  3. A SPECTROSCOPIC SURVEY OF THE FIELDS OF 28 STRONG GRAVITATIONAL LENSES: THE GROUP CATALOG

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, Michelle L.; Zabludoff, Ann I.; Ammons, S. Mark

    With a large, unique spectroscopic survey in the fields of 28 galaxy-scale strong gravitational lenses, we identify groups of galaxies in the 26 adequately sampled fields. Using a group-finding algorithm, we find 210 groups with at least 5 member galaxies; the median number of members is 8. Our sample spans redshifts of 0.04 ≤  z {sub grp} ≤ 0.76 with a median of 0.31, including 174 groups with 0.1 <  z {sub grp} < 0.6. The groups have radial velocity dispersions of 60 ≤  σ {sub grp} ≤ 1200 km s{sup −1} with a median of 350 km s{sup −1}. We also discover a supergroup in field B0712+472 atmore » z = 0.29 that consists of three main groups. We recover groups similar to ∼85% of those previously reported in these fields within our redshift range of sensitivity and find 187 new groups with at least five members. The properties of our group catalog, specifically, (1) the distribution of σ {sub grp}, (2) the fraction of all sample galaxies that are group members, and (3) the fraction of groups with significant substructure, are consistent with those for other catalogs. The distribution of group virial masses agrees well with theoretical expectations. Of the lens galaxies, 12 of 26 (46%) (B1422+231, B1600+434, B2114+022, FBQS J0951+2635, HE0435-1223, HST J14113+5211, MG0751+2716, MGJ1654+1346, PG 1115+080, Q ER 0047-2808, RXJ1131-1231, and WFI J2033-4723) are members of groups with at least five galaxies, and one more (B0712+472) belongs to an additional, visually identified group candidate. There are groups not associated with the lens that still are likely to affect the lens model; in six of 25 (24%) fields (excluding the supergroup), there is at least one massive ( σ {sub grp} ≥ 500 km s{sup −1}) group or group candidate projected within 2′ of the lens.« less

  4. A spectroscopic survey of the fields of 28 strong gravitational lenses: The group catalog

    DOE PAGES

    Wilson, Michelle L.; Zabludoff, Ann I.; Ammons, S. Mark; ...

    2016-12-16

    With a large, unique spectroscopic survey in the fields of 28 galaxy-scale strong gravitational lenses, we identify groups of galaxies in the 26 adequately sampled fields. Using a group-finding algorithm, we find 210 groups with at least 5 member galaxies; the median number of members is 8. Our sample spans redshifts of 0.04 ≤ z grp ≤ 0.76 with a median of 0.31, including 174 groups with 0.1 < z grp < 0.6. The groups have radial velocity dispersions of 60 ≤ σ grp ≤ 1200 km s –1 with a median of 350 km s –1. We also discovermore » a supergroup in field B0712+472 at z = 0.29 that consists of three main groups. We recover groups similar to ~85% of those previously reported in these fields within our redshift range of sensitivity and find 187 new groups with at least five members. The properties of our group catalog, specifically, (1) the distribution of σ grp, (2) the fraction of all sample galaxies that are group members, and (3) the fraction of groups with significant substructure, are consistent with those for other catalogs. The distribution of group virial masses agrees well with theoretical expectations. Of the lens galaxies, 12 of 26 (46%) (B1422+231, B1600+434, B2114+022, FBQS J0951+2635, HE0435-1223, HST J14113+5211, MG0751+2716, MGJ1654+1346, PG 1115+080, Q ER 0047-2808, RXJ1131-1231, and WFI J2033-4723) are members of groups with at least five galaxies, and one more (B0712+472) belongs to an additional, visually identified group candidate. Furthermore, there are groups not associated with the lens that still are likely to affect the lens model; in six of 25 (24%) fields (excluding the supergroup), there is at least one massive (σ grp ≥ 500 km s –1) group or group candidate projected within 2' of the lens.« less

  5. Attenuation of midinfrared free electron laser energy with eyewear

    NASA Astrophysics Data System (ADS)

    Joos, Karen M.; Gabella, William

    2005-04-01

    Purpose: To determine the attenuation of free electron laser (FEL) energy at several wavelengths through microscope objective and eyeglass lenses. Materials and Methods: The FEL at wavelengths of 2.3 um, 2.5 um, 3.0 um, 3.5 um, 4.0 um, 4.5 um, 5.0 um, 6.45 um, 7.0 um, 7.5 um, and 8.0 um was telescoped using a 500 mm nominal focal length lens and a 200 mm focal length lens. The beam had a final spot of about 3 mm and was passed through a 3 mm aperture and onto the 8 mm active area of a J9LP Molectron detector. The eyeglass sample was placed 3 cm in front of the detector. Energy readings were averaged over multiple pulses. Results: Attenuation varied greatly with wavelength and sample from a low attenuation of 0.46 dB, 90% transmission, for short wavelengths through common glass to greater than 60 dB attenuation (transmission at the detector noise level) for IR safe glass by Aura, Inc. Conclusion: Only the designated laser safety goggles effectively attenuate free electron laser energy at 2.3 um and 2.5 um. A microscope objective lens, polycarbonate, and silica glass eyewear is capable of effectively attenuating FEL energy at wavelengths greater than 4.5 um, but the polycarbonate lenses demonstrated material damage.

  6. Age determination of raccoons

    USGS Publications Warehouse

    Grau, G.A.; Sanderson, G.C.; Rogers, J.P.

    1970-01-01

    Age criteria, based on 61 skulls and eye lenses from 103 known-age captives, are described for separating raccoons (Procyon lotor) into eight age-classes as follows: young-of-the-year, 1, 2, 3, 4, 5, 6-7, > 7 years. Criteria studied were eye lens nitrogen, cranial suture closure, tooth wear and incisor cementum layers. Lens nitrogen increased rapidly up to 12 months of age, but at much reduced rate thereafter. Total lens nitrogen was useful only in separating young-of-the-year from adults. The closure sequence for five cranial sutures accurately divided the total known-age sample of males into seven groups, and the adults into five groups. The tooth wear criteria divided the known-age sample into five relative age groups, but aging of individuals by this method was inaccurate. Histological sectioning of known-age teeth was the best method of observing layering in the cementum tissue. The technique of basing estimation of age on cementum ring counts, although subjective, was accurate for aging individuals through their fourth year but tended to underestimate the age of animals over 4 years old. However, suture closure or tooth wear can be used to identify males over 4 years old. In field studies, technical difficulties limit the utility of age estimation by cementum layers. Maximum root thickness of the lower canine was accurate in determining the sex of individuals from 5 months to ,at least 48 months of age.

  7. Interaction of Polarized Light with Chalcogenide Glasses

    DTIC Science & Technology

    2001-06-01

    simultaneous measurement of the laser radiation transmitted through the bulk sample and radiation scattered by the sample to various angles up to 230...fixed in the central part of the lens, reflected the transmitted light beam to a second photodiode. He-Ne laser radiation (), = 633 nm) which was sub...band-gap radiation for the studied bulk glass samples (As 2S3 glass) played in this installation, by turns, a role of inducing or probing light. This

  8. Chromatic correction for a VIS-SWIR zoom lens using optical glasses

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Williams, Daniel J. L.; McCarthy, Peter; Visconti, Anthony J.; Bentley, Julie L.; Moore, Duncan T.

    2015-09-01

    With the advancement in sensors, hyperspectral imaging in short wave infrared (SWIR 0.9 μm to 1.7 μm) now has wide applications, including night vision, haze-penetrating imaging, etc. Most conventional optical glasses can be material candidates for designing in the SWIR as they transmit up to 2.2 μm. However, since SWIR is in the middle of the glasses' major absorption wavebands in UV and IR, the flint glasses in SWIR are less dispersive than in the visible spectrum. As a result, the glass map in the SWIR is highly compressed, with crowns and flints all clustering together. Thus correcting for chromatic aberration is more challenging in the SWIR, since the Abbé number ratio of the same glass combination is reduced. Conventionally, fluorides, such as CaF2 and BaF2, are widely used in designing SWIR system due to their unique dispersion properties, even though they are notorious for poor manufacturability or even high toxicity. For lens elements in a zoom system, the ray bundle samples different sections of the each lens aperture as the lens zooms. This creates extra uncertainty in correcting chromatic aberrations. This paper focuses on using only commercially available optical glasses to color-correct a 3X dual-band zoom lens system in the VIS-SWIR. The design tools and techniques are detailed in terms of material selections to minimize the chromatic aberrations in such a large spectrum band and all zoom positions. Examples are discussed for designs with different aperture stop locations, which considerably affect the material choices.

  9. The Master Lens Database and The Orphan Lenses Project

    NASA Astrophysics Data System (ADS)

    Moustakas, Leonidas

    2012-10-01

    Strong gravitational lenses are uniquely suited for the study of dark matter structure and substructure within massive halos of many scales, act as gravitational telescopes for distant faint objects, and can give powerful and competitive cosmological constraints. While hundreds of strong lenses are known to date, spanning five orders of magnitude in mass scale, thousands will be identified this decade. To fully exploit the power of these objects presently, and in the near future, we are creating the Master Lens Database. This is a clearinghouse of all known strong lens systems, with a sophisticated and modern database of uniformly measured and derived observational and lens-model derived quantities, using archival Hubble data across several instruments. This Database enables new science that can be done with a comprehensive sample of strong lenses. The operational goal of this proposal is to develop the process and the code to semi-automatically stage Hubble data of each system, create appropriate masks of the lensing objects and lensing features, and derive gravitational lens models, to provide a uniform and fairly comprehensive information set that is ingested into the Database. The scientific goal for this team is to use the properties of the ensemble of lenses to make a new study of the internal structure of lensing galaxies, and to identify new objects that show evidence of strong substructure lensing, for follow-up study. All data, scripts, masks, model setup files, and derived parameters, will be public, and free. The Database will be accessible online and through a sophisticated smartphone application, which will also be free.

  10. The retina/RPE proteome in chick myopia and hyperopia models: Commonalities with inherited and age-related ocular pathologies

    PubMed Central

    Riddell, Nina; Faou, Pierre; Murphy, Melanie; Giummarra, Loretta; Downs, Rachael A.; Rajapaksha, Harinda

    2017-01-01

    Purpose Microarray and RNA sequencing studies in the chick model of early optically induced refractive error have implicated thousands of genes, many of which have also been linked to ocular pathologies in humans, including age-related macular degeneration (AMD), choroidal neovascularization, glaucoma, and cataract. These findings highlight the potential relevance of the chick model to understanding both refractive error development and the progression to secondary pathological complications. The present study aimed to determine whether proteomic responses to early optical defocus in the chick share similarities with these transcriptome-level changes, particularly in terms of dysregulation of pathology-related molecular processes. Methods Chicks were assigned to a lens condition (monocular +10 D [diopters] to induce hyperopia, −10 D to induce myopia, or no lens) on post-hatch day 5. Biometric measures were collected following a further 6 h and 48 h of rearing. The retina/RPE was then removed and prepared for liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) on an LTQ-Orbitrap Elite. Raw data were processed using MaxQuant, and differentially abundant proteins were identified using moderated t tests (fold change ≥1.5, Benjamini-Hochberg adjusted p<0.05). These differentially abundant proteins were compared with the genes and proteins implicated in previous exploratory transcriptome and proteomic studies of refractive error, as well as the genes and proteins linked to the ocular pathologies listed above for which myopia or hyperopia are risk factors. Finally, gene set enrichment analysis (GSEA) was used to assess whether gene sets from the Human Phenotype Ontology database were enriched in the lens groups relative to the no lens groups, and at the top or bottom of the protein data ranked by Spearman’s correlation with refraction at 6 and 48 h. Results Refractive errors of −2.63 D ± 0.31 D (mean ± standard error, SE) and 3.90 D ± 0.37 D were evident in the negative and positive lens groups, respectively, at 6 h. By 48 h, refractive compensation to both lens types was almost complete (negative lens −9.70 D ± 0.41 D, positive lens 7.70 D ± 0.44 D). More than 140 differentially abundant proteins were identified in each lens group relative to the no lens controls at both time points. No proteins were differentially abundant between the negative and positive lens groups at 6 h, and 13 were differentially abundant at 48 h. As there was substantial overlap in the proteins implicated across the six comparisons, a total of 390 differentially abundant proteins were identified. Sixty-five of these 390 proteins had previously been implicated in transcriptome studies of refractive error animal models, and 42 had previously been associated with AMD, choroidal neovascularization, glaucoma, and/or cataract in humans. The overlap of differentially abundant proteins with AMD-associated genes and proteins was statistically significant for all conditions (Benjamini-Hochberg adjusted p<0.05), with over-representation analysis implicating ontologies related to oxidative stress, cholesterol homeostasis, and melanin biosynthesis. GSEA identified significant enrichment of genes associated with abnormal electroretinogram, photophobia, and nyctalopia phenotypes in the proteins negatively correlated with ocular refraction across the lens groups at 6 h. The implicated proteins were primarily linked to photoreceptor dystrophies and mitochondrial disorders in humans. Conclusions Optical defocus in the chicks induces rapid changes in the abundance of many proteins in the retina/RPE that have previously been linked to inherited and age-related ocular pathologies in humans. Similar changes have been identified in a meta-analysis of chick refractive error transcriptome studies, highlighting the chick as a model for the study of optically induced stress with possible relevance to understanding the development of a range of pathological states in humans. PMID:29259393

  11. Design for an aberration corrected scanning electron microscope using miniature electron mirrors.

    PubMed

    Dohi, Hideto; Kruit, Pieter

    2018-06-01

    Resolution of scanning electron microscopes (SEMs) is determined by aberrations of the objective lens. It is well known that both spherical and chromatic aberrations can be compensated by placing a 90-degree bending magnet and an electron mirror in the beam path before the objective lens. Nevertheless, this approach has not led to wide use of these aberration correctors, partly because aberrations of the bending magnet can be a serious problem. A mirror corrector with two mirrors placed perpendicularly to the optic axis of an SEM and facing each other is proposed. As a result, only small-angle magnetic deflection is necessary to guide the electron beam around the top mirror to the bottom mirror and around the bottom mirror to the objective lens. The deflection angle, in the order of 50 mrad, is sufficiently small to avoid deflection aberrations. In addition, lateral dispersion at the sample plane can be avoided by making the deflection fields symmetric. Such a corrector system is only possible if the incoming beam can pass the top mirror at a distance in the order of millimeters, without being disturbed by the electric fields of electrodes of the mirror. It is proposed that condition can be satisfied with micro-scale electron optical elements fabricated by using MEMS technology. In the proposed corrector system, the micro-mirrors have to provide the exact negative spherical and chromatic aberrations for correcting the aberration of the objective lens. This exact tuning is accomplished by variable magnification between the micro-mirrors and the objective lens using an additional transfer lens. Extensive optical calculations are reported. Aberrations of the micro-mirrors were analyzed by numerical calculation. Dispersion and aberrations of the deflectors were calculated by using an analytical field model. Combination aberrations caused by the off-axis position of dispersive rays in the mirrors and objective lens were also analyzed. It is concluded that the proposed corrector system will be a promising candidate for simple and low-cost aberration correction in low-voltage SEMs. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Alkali Halide FLIR Lens Development

    DTIC Science & Technology

    1981-10-01

    in the atmosphere. The main emphasis in this 3 report has been development of protective coatings for potassium bromide lenses. The most favorable...placed onto the bottom electrode. Pieces of single-crystalline potassium chloride of approximately the same thickness as coated alkali halide samples...none of the samples appeared to be degraded by the high humidity associated with the exposure. 2. UNITS TESTED Four coated potassium bromide lenses

  13. Mechanical Design Report DARPA BOSS Program

    DTIC Science & Technology

    2008-03-21

    for system mass and length; tolerances for lens spacing, tilt , and diameter; tolerances for lens to lens concentricity and lens perimeter to focus...binding when the lens is compressed, which could otherwise introduce tilt in the lens surface. Part b is the solid stop against which lens 3 (part...Fixed lens angular ( tilt ) accuracy ±3° Lens concentricity ±0.150mm Temperature range 10-45°C Minimum BFL adjustment ±1.5 mm from design focus

  14. How Could Contact Lens Wearers Be at Risk of Acanthamoeba Infection? A Review

    PubMed Central

    Ibrahim, Youhanna W.; Boase, David L.; Cree, Ian A.

    2010-01-01

    Contact lens wear is highly influential on the incidence of ulcerative keratitis worldwide, particularly in developed countries. The association between Acanthamoeba keratitis and contact lens wear is firmly established; it may account for up to 95% of the reported cases. Before the popularisation of soft contact lens wear, Acanthamoeba keratitis was extremely rare. In 2000 it was estimated that the number of contact lens wearers worldwide was about 80 million, out of whom 33 million were in the United States and 90% of them wore hydrogel soft lenses. Contact lens-related problems depend on many factors, such as lens material, wearing modality, lens hygiene, type of lens-caring solution, the degree of compliance of the lens user with lens wear and care procedures, lens overwear, sleeping in lenses, rate of changing lenses, and lens case hygiene. This paper is a thorough review of the literature aiming to highlight the role of one of the main risk factors of infectious keratitis, contact lens wear, and also to show the responsibility of lens users in aggravating this risk.

  15. Stacked lensing estimators and their covariance matrices: Excess surface mass density vs. Lensing shear

    NASA Astrophysics Data System (ADS)

    Shirasaki, Masato; Takada, Masahiro

    2018-05-01

    Stacked lensing is a powerful means of measuring the average mass distribution around large-scale structure tracers. There are two stacked lensing estimators used in the literature, denoted as ΔΣ and γ+, which are related as ΔΣ = Σcrγ+, where Σcr(zl, zs) is the critical surface mass density for each lens-source pair (zl and zs are lens and source redshifts, respectively). In this paper we derive a formula for the covariance matrix of ΔΣ-estimator focusing on "weight" function to improve the signal-to-noise (S/N). We assume that the lensing fields and the distribution of lensing objects obey the Gaussian statistics. With this formula, we show that, if background galaxy shapes are weighted by an amount of Σ _cr^{-2}(z_l,z_s), the ΔΣ-estimator maximizes the S/N in the shot noise limited regime. We also show that the ΔΣ-estimator with the weight Σ _cr^{-2} gives a greater (S/N)2 than that of the γ+-estimator by about 5-25% for lensing objects at redshifts comparable with or higher than the median of source galaxy redshifts for hypothetical Subaru HSC and DES surveys. However, for low-redshift lenses such as zl ≲ 0.3, the γ+-estimator has higher (S/N)2 than ΔΣ. We also discuss that the (S/N)2 for ΔΣ at large separations in the sample variance limited regime can be boosted, by up to a factor of 1.5, if one adopts a weight of Σ _cr^{-α } with α > 2. Our formula allows one to explore how the combination of the different estimators can approach an optimal estimator in all regimes of redshifts and separation scales.

  16. Persistence of increased Eotaxin-1 (CCL11) level in tears of patients wearing contact lenses: a long-term follow-up study.

    PubMed

    Tran, H V; Eperon, S; Guex-Crosier, Y

    2011-04-01

    Eotaxin-1 (CCL11) is a potent eosinophil chemotactic and activating peptide that may be implicated in the pathogenesis of chronic allergic eye disease and has been associated with the wearing of contact lenses (CL) in patients with contact lens papillary conjunctivitis (CLPC). The purpose of this study was to study eotaxin-1 expression in the tears of long-term CL wearers. Tears were collected with glass capillaries from 15 patients (2 male, 13 female) with various degree of CLPC at 2-year intervals. CLPC severity was graded from 0 to 4 with reference to standard slit-lamp photographs of the superior tarsal conjunctiva. The eotaxin-1 level in the tears was measured by an ELISA, using mouse anti-human eotaxin monoclonal antibodies. The mean age was 32.5 ± 13.3 years (range: 17 - 69 years). The mean interval between the tear collections was 30 ± 4.8 months. The mean concentration of eotaxin was 2150 ± 477 pg/mL and 2486 ± 810 pg/mL for the first and second series, respectively. The difference was not statistically significant (paired Wilcoxon/Kruskal-Wallis, p = 0.803). The mean score of papilla grade was 1.26 ± 0.18 for the first sample and 1.40 ± 0.19 two years later. There was no significant difference of grading between the two time periods (paired Wilcoxon/Kruskal-Wallis, p = 0.751). the eotaxin-1 level remains up-regulated over a long time period in patients wearing CL, most of them with chronic CLPC. Eotaxin may play a role in the pathogenesis of contact lens intolerance. © Georg Thieme Verlag KG Stuttgart · New York.

  17. The weight of racism: Vigilance and racial inequalities in weight-related measures.

    PubMed

    Hicken, Margaret T; Lee, Hedwig; Hing, Anna K

    2018-02-01

    In the United States, racial/ethnic inequalities in obesity are well-documented, particularly among women. Using the Chicago Community Adult Health Study, a probability-based sample in 2001-2003 (N = 3105), we examined the roles of discrimination and vigilance in racial inequalities in two weight-related measures, body mass index (BMI) and waist circumference (WC), viewed through a cultural racism lens. Cultural racism creates a social environment in which Black Americans bear the stigma burden of their racial group while White Americans are allowed to view themselves as individuals. We propose that in this context, interpersonal discrimination holds a different meaning for Blacks and Whites, while vigilance captures the coping style for Blacks who carry the stigma burden of the racial group. By placing discrimination and vigilance within the context of cultural racism, we operationalize existing survey measures and utilize statistical models to clarify the ambiguous associations between discrimination and weight-related inequalities in the extant literature. Multivariate models were estimated for BMI and WC separately and were stratified by gender. Black women had higher mean BMI and WC than any other group, as well as highest levels of vigilance. White women did not show an association between vigilance and WC but did show a strong positive association between discrimination and WC. Conversely, Black women displayed an association between vigilance and WC, but not between discrimination and WC. These results demonstrate that vigilance and discrimination may hold different meanings for obesity by ethnoracial group that are concealed when all women are examined together and viewed without considering a cultural racism lens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Computer vision syndrome in presbyopia and beginning presbyopia: effects of spectacle lens type.

    PubMed

    Jaschinski, Wolfgang; König, Mirjam; Mekontso, Tiofil M; Ohlendorf, Arne; Welscher, Monique

    2015-05-01

    This office field study investigated the effects of different types of spectacle lenses habitually worn by computer users with presbyopia and in the beginning stages of presbyopia. Computer vision syndrome was assessed through reported complaints and ergonomic conditions. A questionnaire regarding the type of habitually worn near-vision lenses at the workplace, visual conditions and the levels of different types of complaints was administered to 175 participants aged 35 years and older (mean ± SD: 52.0 ± 6.7 years). Statistical factor analysis identified five specific aspects of the complaints. Workplace conditions were analysed based on photographs taken in typical working conditions. In the subgroup of 25 users between the ages of 36 and 57 years (mean 44 ± 5 years), who wore distance-vision lenses and performed more demanding occupational tasks, the reported extents of 'ocular strain', 'musculoskeletal strain' and 'headache' increased with the daily duration of computer work and explained up to 44 per cent of the variance (rs = 0.66). In the other subgroups, this effect was smaller, while in the complete sample (n = 175), this correlation was approximately rs = 0.2. The subgroup of 85 general-purpose progressive lens users (mean age 54 years) adopted head inclinations that were approximately seven degrees more elevated than those of the subgroups with single vision lenses. The present questionnaire was able to assess the complaints of computer users depending on the type of spectacle lenses worn. A missing near-vision addition among participants in the early stages of presbyopia was identified as a risk factor for complaints among those with longer daily durations of demanding computer work. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  19. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia.

    PubMed

    Cardona, Genís; López, Sílvia

    2016-01-01

    To determine working distance, pupil diameter and illumination in real life conditions in a sample of presbyopic participants performing habitual tasks. A total of 59 presbyopic subjects (aged between 45 and 63 years) with different occupational backgrounds participated in the study. Participants were first interviewed regarding their habitual tasks with the aid of an ad hoc questionnaire, following which in-office photopic and mesopic pupil diameter was determined. Pupil diameter was also evaluated while participants conducted each of the self-reported habitual tasks by taking a photograph, which was later submitted to image analysis. In addition, working distance was determined with a measuring tape and the illumination that reached the pupil during each of the different tasks was measured, in lux, with a light meter. The four most common habitual tasks were computer use, reading, sewing and sports. A high intersubject variability was found in pupil diameter, working distance and illumination conditions while conducting the same task. Statistically significant differences were found between the in-office measured photopic and mesopic pupil diameters and those obtained while participants were conducting their habitual tasks in real life conditions (all p<0.001). Potential multifocal contact lens users may present with different ages, different jobs or hobbies and different preferences regarding lighting conditions and working distances. This results in different pupil size, even within the same task. This information may be critical when selecting a particular lens design and add power. Eye care practitioners are therefore advised to assess pupil diameter in real life conditions. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  20. Quality of sunglasses available in the Iranian market; a study with emphasis on sellers’ license

    PubMed Central

    Bazzazi, Nooshin; Heydarian, Samira; Vahabi, Reihaneh; Akbarzadeh, Siamak; Fouladi, Daniel F

    2015-01-01

    Context: Sunglasses should follow minimum requirements to sufficiently protect eyes. It is not known whether all items obtainable from the market are appropriately designed. Aims: To compare ultraviolet (UV)-protective properties of commercially available sunglasses obtained from authorized and unauthorized Iranian sellers. Settings and Study Design: An analytic-descriptive study performed in a metropolitan area (Tehran). Materials and Methods: Using a UV-visible standard spectrophotometer, the percentage transmittance was scanned between 280 and 400 nm in 348 pairs of nonprescription sunglasses (price range: 20–80 US$) obtained anonymously and randomly from authorized (permitted by the Ministry of Health, 189 pairs) and unauthorized (159 pairs) sellers in the Iranian capital city, Tehran. The Australian/New Zealand Standard (AS/NZS) and the American National Standards Institute [ANSI] standards were followed. Statistical Analysis: Chi-square test, independent samples t-test or Mann–Whitney U-test. Results: UV-protective properties of the sunglasses obtained from authorized sellers complied with AS/NZS and ANSI guidelines in 92.6% and 95.2% of items, respectively. The corresponding rates for sunglasses obtained from unauthorized sellers were 0% and 8.2%, respectively (P < 0.001 for both). The rate of defective polarizing capability of lenses was 27.4% in sunglasses obtained from authorized sellers versus 90.4% in sunglasses obtained from unauthorized sellers (P < 0.001). Neither brand nor price played significant contributions to UV protection/lens polarizing capability of sunglasses obtained from authorized sellers. Conclusions: Sunglasses provided by unauthorized sellers are alarmingly unreliable and could be potentially hazardous for the eye. Brand and price do not guarantee optimal protection against UV radiation or polarizing performance of the lens. PMID:25827547

  1. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    PubMed

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  2. Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources.

    PubMed

    Pincelli, T; Petrov, V N; Brajnik, G; Ciprian, R; Lollobrigida, V; Torelli, P; Krizmancic, D; Salvador, F; De Luisa, A; Sergo, R; Gubertini, A; Cautero, G; Carrato, S; Rossi, G; Panaccione, G

    2016-03-01

    ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

  3. Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

    NASA Astrophysics Data System (ADS)

    Pincelli, T.; Petrov, V. N.; Brajnik, G.; Ciprian, R.; Lollobrigida, V.; Torelli, P.; Krizmancic, D.; Salvador, F.; De Luisa, A.; Sergo, R.; Gubertini, A.; Cautero, G.; Carrato, S.; Rossi, G.; Panaccione, G.

    2016-03-01

    ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

  4. Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pincelli, T., E-mail: pincelli@iom.cnr.it; Rossi, G.; Laboratorio TASC, IOM-CNR, S.S. 14 km 163.5, Basovizza, 34149 Trieste

    2016-03-15

    ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric andmore » magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).« less

  5. Compliance among soft contact lens wearers.

    PubMed

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p < 0.0045 and t = -2.33, df= 48, p < 0.024, respectively). Our study indicates that almost all patients had some degree of non-compliance in lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.

  6. Comparison of Visual Quality after Implantation of Big Bag and Akreos Adapt Intraocular Lenses in Patients with High Myopia.

    PubMed

    Ma, Shengsheng; Zheng, Dongjian; Lin, Ling; Meng, Fanjian; Yuan, Yonggang

    2015-03-01

    To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens (IOL) in patients diagnosed with high myopia complicated with cataract. This was a randomized prospective control study. The patients with high myopia. complicated with cataract, with axial length ≥ 28 mm, and corneal astigmatism ≤ 1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation. At 3 months after surgery, intraocular high-order aberration was measured by a Tracey-iTrace wavefront aberrometer at a pupil diameter of 5 mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Penta-cam three-dimensional anterior segment analyzer. The tilt and decentration of the IOL were calculated by Image-pro plus 6.0 imaging analysis software and statistically compared between two groups. In total, 127 patients (127 eyes), including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group (59 eyes) were significantly higher compared with those in the Big Bag (P < 0.05). The clover and spherical aberration did not differ between the two groups (P > 0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group (both P < 0.05), whereas the tilt of IOL did not significantly differ between the two groups (P > 0.05). Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups.

  7. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    PubMed

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  8. STATISTICS OF MICROLENSING CAUSTIC CROSSINGS IN Q 2237+0305: PECULIAR VELOCITY OF THE LENS GALAXY AND ACCRETION DISK SIZE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mediavilla, E.; Jimenez-Vicente, J.; Muñoz, J. A.

    We use the statistics of caustic crossings induced by microlensing in the lens system Q 2237+0305 to study the lens galaxy peculiar velocity. We calculate the caustic crossing rates for a comprehensive family of stellar mass functions and find a dependence of the average number of caustic crossings with the effective transverse velocity and the average mass, 〈n〉∝v{sub eff}/√(〈m〉), equivalent to the theoretical prediction for the case of microlenses with identical masses. We explore the possibilities of the method to measure v {sub eff} using the ∼12 yr of Optical Gravitational Lensing Experiment monitoring of the four images of Qmore » 2237+0305. To determine a lower limit for v {sub eff}, we count, conservatively, a single caustic crossing for each one of the four high magnification events identified in the literature (plus one additional proposed by us) obtaining v{sub eff}≳240√(〈m〉/0.17 M{sub ⊙}) km s{sup −1} at 68% of confidence. From this value and the average FWHM of the four high magnification events, we obtain a lower limit of r{sub s}≳1.4√(〈m〉/0.17 M{sub ⊙}) light-days for the radius of the source (r{sub s} = FWHM/2.35). Tentative identification of three additional caustic crossing events leads to estimates of v{sub eff}≃(493±246)√(〈m〉/0.17 M{sub ⊙}) km s{sup −1} for the effective transverse velocity and of r{sub s}≃(2.7±1.3)√(〈m〉/0.17 M{sub ⊙}) light-days for the source size. The estimated transverse peculiar velocity of the galaxy is v{sub t}≃(429±246)√(〈m〉/0.17 M{sub ⊙}) km s{sup −1}.« less

  9. Comparison of disposable sutureless silicone ring and traditional metal ring in 23-gauge vitrectomy combined with cataract surgery

    PubMed Central

    Wu, Jian-Guo; Wei, Rui-Hua; Liu, Ai-Hua; Zhou, Xiao-Xu; Sun, Guo-Ling; Li, Xiao-Rong

    2011-01-01

    Background: The purpose of this prospective, interventional, comparative case series was to evaluate the efficiency and feasibility of a disposable sutureless silicone lens ring for corneal contact lens stabilization during combined 23-gauge vitrectomy and cataract surgery. Methods: We developed a ring consisting of a single silicone component with three footplates along the ring margin to fit cannulae for holding conventional contact lenses. Thirty eyes from 30 patients with cataract and vitreoretinal disease were included, and divided into two matched groups according to disease type and ring used. In Group A, we used a 23-gauge transconjunctival vitrectomy system and a disposable sutureless silicone lens ring (n = 15). In Group B, we used a 23-gauge transconjunctival vitrectomy system and a conventional metal lens ring (n = 15). The main outcome measures were: time required for vitrectomy preparation, rate of intraoperative corneal limbus bleeding, and limbus scar rate at the final follow-up visit. Results: Thirty cases were successfully completed. The average vitrectomy preparation time was less in Group A than in Group B (P < 0.01), and the average preparation time saved was 3.94 minutes. None of the Group A patients had intraoperative bleeding or postoperative scarring, whereas all 15 Group B cases had bleeding and five had scarring. There was a statistically significant difference between Group A and Group B for these complications (P ≤ 0.05). Conclusion: This report demonstrates the advantages of using a sutureless silicone ring during combined 23-gauge vitrectomy and cataract surgery. Using this method could allow extra time for the surgeon to pay more attention to complex vitreoretinal procedures. PMID:21760720

  10. Comparison of disposable sutureless silicone ring and traditional metal ring in 23-gauge vitrectomy combined with cataract surgery.

    PubMed

    Wu, Jian-Guo; Wei, Rui-Hua; Liu, Ai-Hua; Zhou, Xiao-Xu; Sun, Guo-Ling; Li, Xiao-Rong

    2011-01-01

    The purpose of this prospective, interventional, comparative case series was to evaluate the efficiency and feasibility of a disposable sutureless silicone lens ring for corneal contact lens stabilization during combined 23-gauge vitrectomy and cataract surgery. We developed a ring consisting of a single silicone component with three footplates along the ring margin to fit cannulae for holding conventional contact lenses. Thirty eyes from 30 patients with cataract and vitreoretinal disease were included, and divided into two matched groups according to disease type and ring used. In Group A, we used a 23-gauge transconjunctival vitrectomy system and a disposable sutureless silicone lens ring (n = 15). In Group B, we used a 23-gauge transconjunctival vitrectomy system and a conventional metal lens ring (n = 15). The main outcome measures were: time required for vitrectomy preparation, rate of intraoperative corneal limbus bleeding, and limbus scar rate at the final follow-up visit. Thirty cases were successfully completed. The average vitrectomy preparation time was less in Group A than in Group B (P < 0.01), and the average preparation time saved was 3.94 minutes. None of the Group A patients had intraoperative bleeding or postoperative scarring, whereas all 15 Group B cases had bleeding and five had scarring. There was a statistically significant difference between Group A and Group B for these complications (P ≤ 0.05). This report demonstrates the advantages of using a sutureless silicone ring during combined 23-gauge vitrectomy and cataract surgery. Using this method could allow extra time for the surgeon to pay more attention to complex vitreoretinal procedures.

  11. Scale dependence of galaxy biasing investigated by weak gravitational lensing: An assessment using semi-analytic galaxies and simulated lensing data

    NASA Astrophysics Data System (ADS)

    Simon, Patrick; Hilbert, Stefan

    2018-05-01

    Galaxies are biased tracers of the matter density on cosmological scales. For future tests of galaxy models, we refine and assess a method to measure galaxy biasing as a function of physical scale k with weak gravitational lensing. This method enables us to reconstruct the galaxy bias factor b(k) as well as the galaxy-matter correlation r(k) on spatial scales between 0.01 h Mpc-1 ≲ k ≲ 10 h Mpc-1 for redshift-binned lens galaxies below redshift z ≲ 0.6. In the refinement, we account for an intrinsic alignment of source ellipticities, and we correct for the magnification bias of the lens galaxies, relevant for the galaxy-galaxy lensing signal, to improve the accuracy of the reconstructed r(k). For simulated data, the reconstructions achieve an accuracy of 3-7% (68% confidence level) over the above k-range for a survey area and a typical depth of contemporary ground-based surveys. Realistically the accuracy is, however, probably reduced to about 10-15%, mainly by systematic uncertainties in the assumed intrinsic source alignment, the fiducial cosmology, and the redshift distributions of lens and source galaxies (in that order). Furthermore, our reconstruction technique employs physical templates for b(k) and r(k) that elucidate the impact of central galaxies and the halo-occupation statistics of satellite galaxies on the scale-dependence of galaxy bias, which we discuss in the paper. In a first demonstration, we apply this method to previous measurements in the Garching-Bonn Deep Survey and give a physical interpretation of the lens population.

  12. The effects of 2 week senofilcon-A silicone hydrogel contact lens daily wear on tear functions and ocular surface health status.

    PubMed

    Dogru, Murat; Ward, Samantha K; Wakamatsu, Tais; Ibrahim, Osama; Schnider, Cristina; Kojima, Takashi; Matsumoto, Yukihiro; Ogawa, Junko; Shimazaki, Jun; Tsubota, Kazuo

    2011-04-01

    To prospectively investigate the effects of 2 week senofilcon A contact lens (CL) daily wear on the functional visual acuity (VA), ocular surface and tear film. Seventeen right eyes of 17 senofilcon A CL wearers without any ocular or systemic diseases were examined before and 2 weeks after lens wear. Visual acuity measurements, tear evaporation rate, ELISA for tear cytokines, strip meniscometry, tear lipid layer interferometry, tear film break-up time (BUT), in vivo confocal microscopy, corneal sensitivity, ocular surface vital staining, Schirmer I test and brush cytology for MUC5AC mRNA expression were performed before and after CL wear. The best corrected Landolt VA, functional VA parameters, the mean lipid layer interferometry grades, tear evaporation rates, Schirmer test values, vital staining scores and in vivo confocal microscopy parameters did not show any significant differences after 2 weeks of CL wear. The tear film BUT showed a significant decrease together with a significant down regulation of MUC5 AC mRNA expression after CL wear. A statistically significant elevation in the mean tear interleukin (IL)-6 concentration was also observed after 2 weeks of CL wear. Two week senofilcon A daily CL wear seems to be associated with tear instability, a decrease in MUC5AC expression, and elevation of IL-6 in tears without significant alterations in epithelial damage scores or in the morphology or density of in vivo keratoconjunctival cells and nerves. Alterations associated with long term wear and patients with dry eye disease need to be studied in future trials. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  13. Medical Malpractice Claims Related to Cataract Surgery Complicated by Retained Lens Fragments (An American Ophthalmological Society Thesis)

    PubMed Central

    Kim, Judy E.; Weber, Paul; Szabo, Aniko

    2012-01-01

    Purpose: To review malpractice claims associated with retained lens fragments during cataract surgery to identify ways to improve patient outcomes. Methods: Retrospective, noncomparative, consecutive case series. Closed claims data related to cataract surgeries complicated by retained lens fragments (1989 through 2009) from an ophthalmic insurance carrier were reviewed. Factors associated with these claims and claims outcomes were analyzed. Results: During the 21-year period, 117 (12.5%) of 937 closed claims associated with cataract surgery were related to retained lens fragments with 108 unique cataract surgeries, 97% against cataract surgeon and 3% against retinal surgeon. Twelve (11%) of 108 claims were resolved by a trial, 30 (28%) were settled, and 66 (61%) were dismissed. The defendant prevailed in 83% of trials. Indemnity payments totaling more than $3,586,000 were made in 32 (30%) of the claims (median payment, $90,000). The difference between the preoperative visual acuity and the final visual acuity was predictive of an indemnity payment (odds ratio [OR], 2.28; P=.001) and going to a trial (OR, 2.93; P=.000). Development of corneal edema was associated with an indemnity payment (OR, 3.50; P=.037). Timing of referral and elevated intraocular pressure (IOP) were statistically significant in univariate analyses but not in multivariate analyses for a trial. Conclusions: Whereas the majority of claims were dismissed, claims associated with greater visual acuity decline, corneal edema, or elevated IOP were more likely to result in a trial or payment. Ways to reduce significant vision loss, including improved management of corneal edema and IOP, and timely referral to a subspecialist should be considered. PMID:23818737

  14. Identifying Anomalies in Gravitational Lens Time Delays

    NASA Astrophysics Data System (ADS)

    Congdon, Arthur B.; Keeton, C. R.; Nordgren, C. E.

    2009-05-01

    Gravitational lensing has become a powerful probe of cold dark matter substructure. Earlier work using anomalous flux ratios in four-image quasar lenses has shown that lensing is sensitive to substructure which raises the exciting prospect of constraining the mass function and spatial distribution of dark matter satellites in galaxies. We examine the ability of gravitational lens time delays to reveal complex structure in lens potentials. We use Monte Carlo simulations to determine the range of time delays that can be produced by realistic smooth lens models consisting of isothermal ellipsoid galaxies with tidal shear. We can then identify outliers as "time-delay anomalies." We find evidence for anomalies in close image pairs in the cusp lenses RX J1131-1231 and B1422+231. The anomalies in RX J1131-1231 provide strong evidence for substructure in the lens potential, while at this point the apparent anomalies in B1422+231 mainly indicate that the time delay measurements need to be improved. We also find evidence for time-delay anomalies in larger-separation image pairs in four additional lenses. We suggest that these anomalies are caused by some combination of substructure and a complex lens environment. Our work argues for a large sample of strong lenses with precisely-measured time delays. The first of these objectives will be readily achievable as the next generation of optical and radio telescopes come online, while the second will require a dedicated one-meter class space-based observatory. Meeting these goals will make it possible to examine the properties of dark matter on sub-galactic scales, which is essential for distinguishing among the various dark matter candidates from particle physics. Part of this work was funded by NSF grant AST-0747311. ABC is currently supported by an appointment to the NASA Postdoctoral Program at the Jet Propulsion Laboratory, administered by Oak Ridge Associated Universities through a contract with NASA.

  15. New web-based algorithm to improve rigid gas permeable contact lens fitting in keratoconus.

    PubMed

    Ortiz-Toquero, Sara; Rodriguez, Guadalupe; de Juan, Victoria; Martin, Raul

    2017-06-01

    To calculate and validate a new web-based algorithm for selecting the back optic zone radius (BOZR) of spherical gas permeable (GP) lens in keratoconus eyes. A retrospective calculation (n=35; multiple regression analysis) and a posterior prospective validation (new sample of 50 keratoconus eyes) of a new algorithm to select the BOZR of spherical KAKC design GP lenses (Conoptica) in keratoconus were conducted. BOZR calculated with the new algorithm, manufacturer guidelines and APEX software were compared with the BOZR that was finally prescribed. Number of diagnostic lenses, ordered lenses and visits to achieve optimal fitting were recorded and compared those obtained for a control group [50 healthy eyes fitted with spherical GP (BIAS design; Conoptica)]. The new algorithm highly correlated with the final BOZR fitted (r 2 =0.825, p<0.001). BOZR of the first diagnostic lens using the new algorithm demonstrated lower difference with the final BOZR prescribed (-0.01±0.12mm, p=0.65; 58% difference≤0.05mm) than with the manufacturer guidelines (+0.12±0.22mm, p<0.001; 26% difference≤0.05mm) and APEX software (-0.14±0.16mm, p=0.001; 34% difference≤0.05mm). Close numbers of diagnostic lens (1.6±0.8, 1.3±0.5; p=0.02), ordered lens (1.4±0.6, 1.1±0.3; P<0.001), and visits (3.4±0.7, 3.2±0.4; p=0.08) were required to fit keratoconus and healthy eyes, respectively. This new algorithm (free access at www.calculens.com) improves spherical KAKC GP fitting in keratoconus and can reduce the practitioner and patient chair time to achieve a final acceptable fit in keratoconus. This algorithm reduces differences between keratoconus GP fitting (KAKC design) and standard GP (BIAS design) lenses fitting in healthy eyes. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Demonstration of Single-Shot Picosecond Time-Resolved MeV Electron Imaging Using a Compact Permanent Magnet Quadrupole Based Lens

    NASA Astrophysics Data System (ADS)

    Cesar, D.; Maxson, J.; Musumeci, P.; Sun, Y.; Harrison, J.; Frigola, P.; O'Shea, F. H.; To, H.; Alesini, D.; Li, R. K.

    2016-07-01

    We present the results of an experiment where a short focal length (˜1.3 cm ), permanent magnet electron lens is used to image micron-size features (of a metal sample) with a single shot from an ultrahigh brightness picosecond-long 4 MeV electron beam emitted by a radio-frequency photoinjector. Magnification ratios in excess of 30 × were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permanent magnet quadrupoles with nearly 600 T /m field gradients. These results pave the way towards single-shot time-resolved electron microscopy and open new opportunities in the applications of high brightness electron beams.

  17. Comparative analysis of lip with thumbprints: An identification tool in personal authentication.

    PubMed

    Naik, Rashmi; Ahmed Mujib, B R; Telagi, Neethu; Hallur, Jaydeva

    2017-01-01

    Identification of person living or dead using diverse characteristics is the basis in forensic science. The uniqueness of lip and fingerprints and further, association between them can be useful in establishing facts in legal issues. The present study was carried out to determine the distribution of different lip print patterns among subjects having different thumbprint patterns and to determine the correlation between lip print patterns and thumbprint patterns. The study sample comprised 100 students randomly selected from Bapuji Dental College Hospital, Davangere, Karnataka, 50 males and 50 females aged between 18 and 20 years. Red colored lipstick was applied on the lips by a lipstick applicator brush. Lip and thumb impressions were made on No. 1 Whatman filter paper and visualized using magnifying lens. Three main types of fingerprints (loop, whorl and arch) were identified; Tsuchihashi Y classification of lip print patterns was followed in the study. Chi-square test was used to see the association between lip and thumbprints. The correlation between lip and left thumb print patterns for gender identification was statistically significant. In both males and females, Type II lip pattern associated with loop finger pattern were most significant and in males, Type III lip pattern with whorl type of finger pattern showed statistical significance. We conclude that the correlation found between lip print and thumbprint can be utilized in the field of forensic science for gender identification.

  18. Iron oxide functionalized graphene oxide as an efficient sorbent for dispersive micro-solid phase extraction of sulfadiazine followed by spectrophotometric and mode-mismatched thermal lens spectrometric determination.

    PubMed

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Amir; Rashidian Vaziri, Mohammad Reza; Behjat, Abbas

    2016-01-15

    A simple and rapid dispersive micro-solid phase extraction (DMSPE) combined with mode-mismatched thermal lens spectrometry as well as fiber optic linear array spectrophotometry was developed for the separation, extraction and determination of sulfadiazine. Graphene oxide was synthesized using the modified Hummers method and functionalized with iron oxide nanoparticles by means of a simple one step chemical coprecipitation method. The synthesized iron oxide functionalized graphene oxide was utilized as an efficient sorbent in DMSPE of sulfadiazine. The retained analyte was eluted by using 180µL of a 6:4 mixture of methanol/acetic acid solution and was spectrophotometrically determined based on the formation of an azo dye through coupling with thenoyltrifluoroacetone. Under the optimized conditions, with the application of spectrophotometry technique and with a sample volume of 100mL, the method exhibited a linear dynamic range of 3-80µg L(-1) with a detection limit of 0.82µg L(-1), an enrichment factor of 200 as well as the relative standard deviations of 2.6% and 4.3% (n=6) at 150µg L(-1) level of sulfadiazine for intra- and inter-day analyses, respectively. Whereas, through the application of the thermal lens spectrometry and a sample volume of 10mL, the method exhibited a linear dynamic range of 1-800µg L(-1) with a detection limit of 0.34µg L(-1) and the relative standard deviations of 3.1% and 5.4% (n=6) at 150µg L(-1) level of sulfadiazine for intra- and inter-day analyses, respectively. The method was successfully applied to the determination of sulfadiazine in milk, honey and water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. The Grism Lens-Amplified Survey from Space (GLASS). V. Extent and Spatial Distribution of Star Formation in z ~ 0.5 Cluster Galaxies

    NASA Astrophysics Data System (ADS)

    Vulcani, Benedetta; Treu, Tommaso; Schmidt, Kasper B.; Poggianti, Bianca M.; Dressler, Alan; Fontana, Adriano; Bradač, Marusa; Brammer, Gabriel B.; Hoag, Austin; Huang, Kuan-Han; Malkan, Matthew; Pentericci, Laura; Trenti, Michele; von der Linden, Anja; Abramson, Louis; He, Julie; Morris, Glenn

    2015-12-01

    We present the first study of the spatial distribution of star formation in z ˜ 0.5 cluster galaxies. The analysis is based on data taken with the Wide Field Camera 3 as part of the Grism Lens-Amplified Survey from Space (GLASS). We illustrate the methodology by focusing on two clusters (MACS 0717.5+3745 and MACS 1423.8+2404) with different morphologies (one relaxed and one merging) and use foreground and background galaxies as a field control sample. The cluster+field sample consists of 42 galaxies with stellar masses in the range 108-1011 M⊙ and star formation rates in the range 1-20 M⊙ yr-1. Both in clusters and in the field, Hα is more extended than the rest-frame UV continuum in 60% of the cases, consistent with diffuse star formation and inside-out growth. In ˜20% of the cases, the Hα emission appears more extended in cluster galaxies than in the field, pointing perhaps to ionized gas being stripped and/or star formation being enhanced at large radii. The peak of the Hα emission and that of the continuum are offset by less than 1 kpc. We investigate trends with the hot gas density as traced by the X-ray emission, and with the surface mass density as inferred from gravitational lens models, and find no conclusive results. The diversity of morphologies and sizes observed in Hα illustrates the complexity of the environmental processes that regulate star formation. Upcoming analysis of the full GLASS data set will increase our sample size by almost an order of magnitude, verifying and strengthening the inference from this initial data set.

  20. [A case of invasion of the hyaloid artery into the lens].

    PubMed

    Machida, H; Watanabe, I

    1992-11-01

    A 6-year-old boy with hyaloid artery invasion into the crystalline lens is reported. Both lenses had localized opacities and some brown membranous tissue attached to the posterior lens capsule. He had bilateral persistent hyaloid arteries, and in the right eye this vessel penetrated the lens capsule and invaded the lens. The lens opacity had not increased for 6 years. In persistent hyperplastic primary vitreous we can often see the invasion of fibrovascular tissue into the lens, and this process usually leads to destruction and absorption of the lens. This is an unusual case because the lens showed no significant changes for long period of time in spite of vascular invasion into the lens.

  1. Magnetostrictive performance of additively manufactured CoFe rods using the LENS (TM) system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Nicholas J.; Yoo, Jin-Hyeong; Ott, Ryan T.

    Magnetostrictive materials exhibit a strain in the presence of a variable magnetic field. While they normally require large, highly oriented crystallographic grains for high strain values, metal additive manufacturing (3D printing) may be able to produce highly textured polycrystalline rods, with properties comparable to those manufactured using the more demanding free standing zone melting (FSZM) technique. Rods of Co 75.8Fe 24.2 and Co 63.7Fe 36.3 have been fabricated using the Laser engineered net shaping (LENS TM) system to evaluate the performance of additively manufactured magnetic and magnetostrictive materials. The 76% Co sample showed an average magnetostriction (λ) of 86 ppmmore » at a stress of 124 MPa; in contrast, the 64% Co sample showed only 27 ppm at the same stress. For direct comparison, a Co 67Fe 33 single crystal disk, also measured as part of this study, exhibited a magnetostriction value of 131 and 91 microstrain in the [100] and [111] directions, respectively, with a calculated polycrystalline value (λ s) of 107 microstrain. Electron back scattered diffraction (EBSD) has been used to qualitatively link the performance with crystallographic orientation and phase information, showing only the BCC phase in the 76% Co sample, but three different phases (BCC, FCC, and HCP) in the 64% Co sample.« less

  2. Simultaneous Scanning Electron Microscope Imaging of Topographical and Chemical Contrast Using In-Lens, In-Column, and Everhart-Thornley Detector Systems.

    PubMed

    Zhang, Xinming; Cen, Xi; Ravichandran, Rijuta; Hughes, Lauren A; van Benthem, Klaus

    2016-06-01

    The scanning electron microscope provides a platform for subnanometer resolution characterization of material morphology with excellent topographic and chemical contrast dependent on the used detectors. For imaging applications, the predominantly utilized signals are secondary electrons (SEs) and backscattered electrons (BSEs) that are emitted from the sample surface. Recent advances in detector technology beyond the traditional Everhart-Thornley geometry have enabled the simultaneous acquisition and discrimination of SE and BSE signals. This study demonstrates the imaging capabilities of a recently introduced new detector system that consists of the combination of two in-lens (I-L) detectors and one in-column (I-C) detector. Coupled with biasing the sample stage to reduce electron-specimen interaction volumes, this trinity of detector geometry allows simultaneous acquisition of signals to distinguish chemical contrast from topographical changes of the sample, including the identification of surface contamination. The I-C detector provides 4× improved topography, whereas the I-L detector closest to the sample offers excellent simultaneous chemical contrast imaging while not limiting the minimization of working distance to obtain optimal lateral resolution. Imaging capabilities and contrast mechanisms for all three detectors are discussed quantitatively in direct comparison to each other and the conventional Everhart-Thornley detector.

  3. Magnetostrictive performance of additively manufactured CoFe rods using the LENS (TM) system

    DOE PAGES

    Jones, Nicholas J.; Yoo, Jin-Hyeong; Ott, Ryan T.; ...

    2018-05-01

    Magnetostrictive materials exhibit a strain in the presence of a variable magnetic field. While they normally require large, highly oriented crystallographic grains for high strain values, metal additive manufacturing (3D printing) may be able to produce highly textured polycrystalline rods, with properties comparable to those manufactured using the more demanding free standing zone melting (FSZM) technique. Rods of Co 75.8Fe 24.2 and Co 63.7Fe 36.3 have been fabricated using the Laser engineered net shaping (LENS TM) system to evaluate the performance of additively manufactured magnetic and magnetostrictive materials. The 76% Co sample showed an average magnetostriction (λ) of 86 ppmmore » at a stress of 124 MPa; in contrast, the 64% Co sample showed only 27 ppm at the same stress. For direct comparison, a Co 67Fe 33 single crystal disk, also measured as part of this study, exhibited a magnetostriction value of 131 and 91 microstrain in the [100] and [111] directions, respectively, with a calculated polycrystalline value (λ s) of 107 microstrain. Electron back scattered diffraction (EBSD) has been used to qualitatively link the performance with crystallographic orientation and phase information, showing only the BCC phase in the 76% Co sample, but three different phases (BCC, FCC, and HCP) in the 64% Co sample.« less

  4. Hard parts chemical composition as a potentially valuable tool for kutum, Rutilus kutum stock discrimination: A case study of the Southern Caspian Sea

    NASA Astrophysics Data System (ADS)

    Pourang, N.; Haghighi, F. Parafkandeh; Moazami, H. R.

    2018-07-01

    The potential use of elemental fingerprinting of five hard parts (otolith, scale, dorsal spine, eye lens and vertebral bone) for stock discrimination of Rutilus kutum from the Caspian Sea was investigated, for the first time. The specimens were sampled from three sampling sites in the Southern Caspian Sea in March 2016. Twenty specimens (total length: 32.6-37.9 mm; age: 3-4 yrs) were collected from each site. Concentrations of elements (Br, Ca, Cl, Cu, Fe, K, Mg, Mn, Na, P, S, Sr and Zn) in the samples were determined by proton induced X-ray emission (PIXE). The pattern of elements occurrence in the eye lens was considerably different compared to the other hard parts. No significant differences were found in the Sr level in otolith between the sampling sites 2 and 3 (adjacent to the estuaries of Tajan and Gorganrud rivers, respectively) indicating that the specimens collected from the two sites are probably from the same population. Similar results were also obtained based on the results concerning K accumulation in scales. Generally, it can be concluded that scales may provide an alternative structure to otolith for stock discrimination of R. kutum in the southern Caspian Sea.

  5. Probing cluster potentials through gravitational lensing of background X-ray sources

    NASA Technical Reports Server (NTRS)

    Refregier, A.; Loeb, A.

    1996-01-01

    The gravitational lensing effect of a foreground galaxy cluster, on the number count statistics of background X-ray sources, was examined. The lensing produces a deficit in the number of resolved sources in a ring close to the critical radius of the cluster. The cluster lens can be used as a natural telescope to study the faint end of the (log N)-(log S) relation for the sources which account for the X-ray background.

  6. Using a psychometric lens to examine gender differences on the FCI

    NASA Astrophysics Data System (ADS)

    Lindell, Rebecca; Papak, Alexis; Stewart, John; Traxler, Adrienne

    2017-01-01

    Multiple research studies show that there appears to be an inherent difference between male and female students' performance on the Force Concept Inventory (FCI). Unlike these studies, we chose to create two different samples, one with only female students and the other with only male students, to reduce the effects of the gender-imbalance inherent in a single sample of all physics students. Using a psychometric lens, we evaluate the differences between the male and female students' performance on the FCI. We utilized classical test theory to flag 13 items on the FCI that were poorly functioning for female students. Notably, most of these items were not flagged when the dataset was aggregated across genders. In the next stage of the research, we utilized Item Response Theory (IRT) to discover if the remaining 17 items on the FCI are also poorly functioning for female students. By eliminating the poorly functioning items on the FCI, we further examined the gender difference of the Force Concept Inventory.

  7. An evaluation of the accuracy of the ORange (Gen II) by comparing it to the IOLMaster in the prediction of postoperative refraction.

    PubMed

    Chen, Ming

    2012-01-01

    The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). The Surgical Suites, Honolulu, HI. The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalent refraction from IOLMaster(®) (Carl Zeiss AG, Oberkochen, Germany) and ORange Gen II were statistically compared and verified with 1-month postoperative manifest refraction. The data were put into IBM SPSS 19 (SPSS Inc, Chicago, IL) for analysis of variance. Pearson's correlation coefficient was also calculated to evaluate the correlation between the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction. There were no statistically significant differences in the mean spherical equivalent refraction from the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction (IOLMaster -0.40 diopters, P = 0.07; ORange Gen II -0.43 diopters, P = 0.16; 1-month refraction -0.41 diopters, P = 0.07). Pearson's correlation study demonstrated that all three were positively correlated (P < 0.05), with the strongest correlation between the ORange Gen II and 1-month postoperative manifest refraction (r = +0.6, P < 0.01). The ORange Gen II can be considered as an alternative method for intraocular lens selection for cataract patients.

  8. The Lens Capsule

    PubMed Central

    Danysh, Brian P.; Duncan, Melinda K.

    2009-01-01

    The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892

  9. Tryptophan and Non-Tryptophan Fluorescence of the Eye Lens Proteins Provides Diagnostics of Cataract at the Molecular Level

    PubMed Central

    Gakamsky, Anna; Duncan, Rory R.; Howarth, Nicola M.; Dhillon, Baljean; Buttenschön, Kim K.; Daly, Daniel J.; Gakamsky, Dmitry

    2017-01-01

    The chemical nature of the non-tryptophan (non-Trp) fluorescence of porcine and human eye lens proteins was identified by Mass Spectrometry (MS) and Fluorescence Steady-State and Lifetime spectroscopy as post-translational modifications (PTM) of Trp and Arg amino acid residues. Fluorescence intensity profiles measured along the optical axis of human eye lenses with age-related nuclear cataract showed increasing concentration of fluorescent PTM towards the lens centre in accord with the increased optical density in the lens nucleolus. Significant differences between fluorescence lifetimes of “free” Trp derivatives hydroxytryptophan (OH-Trp), N-formylkynurenine (NFK), kynurenine (Kyn), hydroxykynurenine (OH-Kyn) and their residues were observed. Notably, the lifetime constants of these residues in a model peptide were considerably greater than those of their “free” counterparts. Fluorescence of Trp, its derivatives and argpyrimidine (ArgP) can be excited at the red edge of the Trp absorption band which allows normalisation of the emission spectra of these PTMs to the fluorescence intensity of Trp, to determine semi-quantitatively their concentration. We show that the cumulative fraction of OH-Trp, NFK and ArgP emission dominates the total fluorescence spectrum in both emulsified post-surgical human cataract protein samples, as well as in whole lenses and that this correlates strongly with cataract grade and age. PMID:28071717

  10. Intraocular lens bioactivity tested using rabbit corneal tissue cultures.

    PubMed

    Linnola, R J; Salonen, J I; Happonen, R P

    1999-11-01

    To evaluate the effects of different intraocular lens (IOL) materials on epithelial cell growth to test the sandwich theory; i.e., a bioactivity-based explanation of posterior capsule opacification (PCO) after cataract surgery. Central Hospital, Vaasa, and Institute of Dentistry and Turku Center for Biomaterials, University of Turku, Finland. Rabbit corneal tissue cultures were set up on poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, silicone, acrylate, and hydrogel IOLs for 1 week. The tissue consisted of intact epithelium and half the thickness of the corneal stroma, which was placed against the IOL. The growth of the epithelium was examined by light microscopy to evaluate the attachment of the corneal explant to the IOL surface. All tissue samples grew well under the culture conditions. When grown on PMMA, HSM PMMA, silicone, and hydrogel, the tissue did not attach to the IOL or the epithelium grew around the explant, suggesting that the attachment of the stroma to the IOL was poor or nonexistent. Some explants on acrylate IOLs attached directly to the IOL surface with no epithelial ingrowth between the stroma and the IOL. This tissue culture method can be used to examine the behavior of corneal tissue in contact with different IOL materials. The results suggest that the acrylate IOL may have bioactive properties. This, with the lens optic's square edge, may hinder lens epithelial cell proliferation and thus prevent PCO.

  11. Bacterial adhesion forces to Ag-impregnated contact lens cases and transmission to contact lenses.

    PubMed

    Qu, Wenwen; Busscher, Henk J; van der Mei, Henny C; Hooymans, Johanna M M

    2013-03-01

    To measure adhesion forces of Pseudomonas aeruginosa, Staphylococcus aureus, and Serratia marcescens to a rigid contact lens (CL), standard polypropylene, and Ag-impregnated lens cases using atomic force microscopy and determine bacterial transmission from lens case to CL. Adhesion forces of bacterial strains to Ag-impregnated and polypropylene lens cases and a rigid CL were measured using atomic force microscopy. Adhesion forces were used to calculate Weibull distributions, from which transmission probabilities from lens case to CL were derived. Transmission probabilities were compared with actual transmission of viable bacteria from a lens case to the CL in 0.9% NaCl and in an antimicrobial lens care solution. Bacterial transmission probabilities from polypropylene lens cases based on force analysis coincided well for all strains with actual transmission in 0.9% NaCl. Bacterial adhesion forces on Ag-impregnated lens cases were much smaller than that on polypropylene and CLs, yielding a high probability of transmission. Comparison with actual bacterial transmission indicated bacterial killing due to Ag ions during colony-forming unit transmission from an Ag-impregnated lens case, especially for P. aeruginosa. Transmission of viable bacteria from Ag-impregnated lens cases could be further decreased by use of an antimicrobial lens care solution instead of 0.9% NaCl. Bacterial transmission probabilities are higher from Ag-impregnated lens cases than from polypropylene lens cases because of small adhesion forces, but this is compensated for by enhanced bacterial killing due to Ag impregnation, especially when in combination with an antimicrobial lens care solution. This calls for a balanced combination of antimicrobial lens care solutions and surface properties of a lens case and CL.

  12. Differentiation State-Specific Mitochondrial Dynamic Regulatory Networks Are Revealed by Global Transcriptional Analysis of the Developing Chicken Lens

    PubMed Central

    Chauss, Daniel; Basu, Subhasree; Rajakaruna, Suren; Ma, Zhiwei; Gau, Victoria; Anastas, Sara; Brennan, Lisa A.; Hejtmancik, J. Fielding; Menko, A. Sue; Kantorow, Marc

    2014-01-01

    The mature eye lens contains a surface layer of epithelial cells called the lens epithelium that requires a functional mitochondrial population to maintain the homeostasis and transparency of the entire lens. The lens epithelium overlies a core of terminally differentiated fiber cells that must degrade their mitochondria to achieve lens transparency. These distinct mitochondrial populations make the lens a useful model system to identify those genes that regulate the balance between mitochondrial homeostasis and elimination. Here we used an RNA sequencing and bioinformatics approach to identify the transcript levels of all genes expressed by distinct regions of the lens epithelium and maturing fiber cells of the embryonic Gallus gallus (chicken) lens. Our analysis detected more than 15,000 unique transcripts expressed by the embryonic chicken lens. Of these, more than 3000 transcripts exhibited significant differences in expression between lens epithelial cells and fiber cells. Multiple transcripts coding for separate mitochondrial homeostatic and degradation mechanisms were identified to exhibit preferred patterns of expression in lens epithelial cells that require mitochondria relative to lens fiber cells that require mitochondrial elimination. These included differences in the expression levels of metabolic (DUT, PDK1, SNPH), autophagy (ATG3, ATG4B, BECN1, FYCO1, WIPI1), and mitophagy (BNIP3L/NIX, BNIP3, PARK2, p62/SQSTM1) transcripts between lens epithelial cells and lens fiber cells. These data provide a comprehensive window into all genes transcribed by the lens and those mitochondrial regulatory and degradation pathways that function to maintain mitochondrial populations in the lens epithelium and to eliminate mitochondria in maturing lens fiber cells. PMID:24928582

  13. Do swimming goggles limit microbial contamination of contact lenses?

    PubMed

    Wu, Yvonne T; Tran, Jess; Truong, Michelle; Harmis, Najat; Zhu, Hua; Stapleton, Fiona

    2011-04-01

    Wearing goggles over contact lenses while swimming is often recommended by eye care professionals. Limited data are available to assess this recommendation. The purpose of this study was to examine whether wearing goggles while swimming limits bacterial colonization on contact lenses and whether the type of lens worn affects contamination rates. Twenty-three subjects underwent two swimming sessions at an ocean (salt water) pool (Maroubra beach Rock Pool, Sydney, Australia). Silicone hydrogel (Ciba Focus Night and Day) or hydrogel lenses (Ciba Focus Daily) were inserted into subjects' eyes before 30 min of swimming sessions, and subjects used modified goggles to mimic goggled and non-goggled conditions. At the end of each session, lenses were collected for microbial investigation. Viable bacterial colonies were classified as gram positive and gram negative and enumerated. The level of bacterial colonization on contact lenses between goggled and non-goggled conditions and between the two lens materials were compared. The range of colony forming units recovered from goggled lenses were 0 to 930 compared with 0 to 1210 on non-goggled lenses. The majority of subjects (16/23) had more microorganisms in the non-goggled condition than when wearing goggles (p = 0.03). Gram negative organisms were found in three non-goggled lenses. No significant difference was shown in the number of bacteria isolated from silicone hydrogel and hydrogel lenses (p > 0.6) irrespective of wearing goggles. Water samples had consistently higher numbers of bacterial counts than those adhered to the lenses; however, no association was found between the number of bacteria in the water sample and those found on the contact lenses. Consistently, fewer bacterial colonies were found on the goggled contact lens, thus suggesting goggles offer some protection against bacterial colonization of contact lenses while swimming. These data would support the recommendation encouraging lens wearers to use goggles while swimming.

  14. Paraxial light distribution in the focal region of a lens: a comparison of several analytical solutions and a numerical result.

    PubMed

    Wu, Yang; Kelly, Damien P

    2014-12-12

    The distribution of the complex field in the focal region of a lens is a classical optical diffraction problem. Today, it remains of significant theoretical importance for understanding the properties of imaging systems. In the paraxial regime, it is possible to find analytical solutions in the neighborhood of the focus, when a plane wave is incident on a focusing lens whose finite extent is limited by a circular aperture. For example, in Born and Wolf's treatment of this problem, two different, but mathematically equivalent analytical solutions, are presented that describe the 3D field distribution using infinite sums of [Formula: see text] and [Formula: see text] type Lommel functions. An alternative solution expresses the distribution in terms of Zernike polynomials, and was presented by Nijboer in 1947. More recently, Cao derived an alternative analytical solution by expanding the Fresnel kernel using a Taylor series expansion. In practical calculations, however, only a finite number of terms from these infinite series expansions is actually used to calculate the distribution in the focal region. In this manuscript, we compare and contrast each of these different solutions to a numerically calculated result, paying particular attention to how quickly each solution converges for a range of different spatial locations behind the focusing lens. We also examine the time taken to calculate each of the analytical solutions. The numerical solution is calculated in a polar coordinate system and is semi-analytic. The integration over the angle is solved analytically, while the radial coordinate is sampled with a sampling interval of [Formula: see text] and then numerically integrated. This produces an infinite set of replicas in the diffraction plane, that are located in circular rings centered at the optical axis and each with radii given by [Formula: see text], where [Formula: see text] is the replica order. These circular replicas are shown to be fundamentally different from the replicas that arise in a Cartesian coordinate system.

  15. Paraxial light distribution in the focal region of a lens: a comparison of several analytical solutions and a numerical result

    NASA Astrophysics Data System (ADS)

    Wu, Yang; Kelly, Damien P.

    2014-12-01

    The distribution of the complex field in the focal region of a lens is a classical optical diffraction problem. Today, it remains of significant theoretical importance for understanding the properties of imaging systems. In the paraxial regime, it is possible to find analytical solutions in the neighborhood of the focus, when a plane wave is incident on a focusing lens whose finite extent is limited by a circular aperture. For example, in Born and Wolf's treatment of this problem, two different, but mathematically equivalent analytical solutions, are presented that describe the 3D field distribution using infinite sums of ? and ? type Lommel functions. An alternative solution expresses the distribution in terms of Zernike polynomials, and was presented by Nijboer in 1947. More recently, Cao derived an alternative analytical solution by expanding the Fresnel kernel using a Taylor series expansion. In practical calculations, however, only a finite number of terms from these infinite series expansions is actually used to calculate the distribution in the focal region. In this manuscript, we compare and contrast each of these different solutions to a numerically calculated result, paying particular attention to how quickly each solution converges for a range of different spatial locations behind the focusing lens. We also examine the time taken to calculate each of the analytical solutions. The numerical solution is calculated in a polar coordinate system and is semi-analytic. The integration over the angle is solved analytically, while the radial coordinate is sampled with a sampling interval of ? and then numerically integrated. This produces an infinite set of replicas in the diffraction plane, that are located in circular rings centered at the optical axis and each with radii given by ?, where ? is the replica order. These circular replicas are shown to be fundamentally different from the replicas that arise in a Cartesian coordinate system.

  16. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    PubMed Central

    Vilar, César; Hida, Wilson Takashi; de Medeiros, André Lins; Magalhães, Klayny Rafaella Pereira; de Moraes Tzelikis, Patrick Frensel; Chaves, Mario Augusto Pereira Dias; Motta, Antônio Francisco Pimenta; Carricondo, Pedro Carlos; Alves, Milton Ruiz; Nosé, Walton

    2017-01-01

    Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions. PMID:28814826

  17. Comparison of OVD and BSS for Maintaining the Anterior Chamber during IOL Implantation

    PubMed Central

    Lee, Ho Young; Choy, Yoon Jung

    2011-01-01

    Purpose To compare surgical results between conventional intraocular lens (IOL) implantation using an ophthalmic viscosurgical device (OVD) and IOL implantation using a balanced salt solution (BSS) after irrigation/aspiration (I/A) of the lens cortex. Methods A randomized prospective study was conducted on 62 patients who underwent cataract surgery. Following completion of conventional I/A of the lens cortex, we divided patients into two groups according to whether or not BSS was used. In group A (n = 31), the anterior chamber and the capsular bag were completely filled with an OVD before IOL implantation. On the other hand, in group B (n = 31), BSS was irrigated into the anterior chamber through a previous side port during IOL implantation. Surgical results were compared between the two groups. Results In both groups, IOP peaked six hours after surgery. The occurrence of an IOP spike by postoperative day one was observed in six cases (6 / 31) in group A and in no cases (0 / 31) in group B, a difference that was statistically significant (p = 0.024). The values of endothelial cell density, central corneal thickness, anterior chamber inflammation, myopic shift, and posterior capsule opacification were not significantly different between the two groups. Conclusions Compared with the use of OVD for IOL implantation, use of BSS during IOL implantation resulted in reductions in postoperative IOP spike and OVD removal time. PMID:21350689

  18. [Slit lamp optical coherence tomography study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation].

    PubMed

    Yan, Pi-song; Zhang, Zhen-ping; Lin, Hao-tian; Wu, Wen-jie; Bai, Ling

    2009-09-01

    To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery (CCT increased 99.59 microm, ICT increased 234.57 microm; P = 0.490). At 1 month, the CCT almost had returned to baseline, but the ICT had been thicker about 19.25 microm than baseline(P = 0.001). The measurements of ACD, AOD500, AOD750, TISA500, TISA750 also increased significantly 1 day after surgery. Although the ACD had no changes within 2 weeks (all P < 0.05), it had been not stable. The changes of the width of the anterior chamber had been stable in the early period after surgery (all P > 0.05). The SL-OCT could impersonality and quantificationally evaluate the anterior segment changes induced by cataract surgery.

  19. N-myc regulates growth and fiber cell differentiation in lens development

    PubMed Central

    Cavalheiro, Gabriel R.; Matos-Rodrigues, Gabriel E.; Zhao, Yilin; Gomes, Anielle L.; Anand, Deepti; Predes, Danilo; de Lima, Silmara; Abreu, Jose G.; Zheng, Deyou; Lachke, Salil A.; Cvekl, Ales; Martins, Rodrigo A. P.

    2017-01-01

    Myc proto-oncogenes regulate diverse cellular processes during development, but their roles during morphogenesis of specific tissues are not fully understood. We found that c-myc regulates cell proliferation in mouse lens development and previous genome-wide studies suggested functional roles for N-myc in developing lens. Here, we examined the role of N-myc in mouse lens development. Genetic inactivation of N-myc in the surface ectoderm or lens vesicle impaired eye and lens growth, while "late" inactivation in lens fibers had no effect. Unexpectedly, defective growth of N-myc--deficient lenses was not associated with alterations in lens progenitor cell proliferation or survival. Notably, N-myc-deficient lens exhibited a delay in degradation of DNA in terminally differentiating lens fiber cells. RNA-sequencing analysis of N-myc--deficient lenses identified a cohort of down-regulated genes associated with fiber cell differentiation that included DNaseIIβ. Further, an integrated analysis of differentially expressed genes in N-myc-deficient lens using normal lens expression patterns of iSyTE, N-myc-binding motif analysis and molecular interaction data from the String database led to the derivation of an N-myc-based gene regulatory network in the lens. Finally, analysis of N-myc and c-myc double-deficient lens demonstrated that these Myc genes cooperate to drive lens growth prior to lens vesicle stage. Together, these findings provide evidence for exclusive and cooperative functions of Myc transcription factors in mouse lens development and identify novel mechanisms by which N-myc regulates cell differentiation during eye morphogenesis. PMID:28716713

  20. Optical design and evaluation of a 4 mm cost-effective ultra-high-definition arthroscope.

    PubMed

    Cheng, Dewen; Wang, Yongtian; Yu, Lu; Liu, Xiaohua

    2014-08-01

    High definition and magnification rigid endoscope plays an important role in modern minimally invasive medical surgery and diagnosis. In this paper, we present the design and evaluation methods of a high definition rigid endoscope, specifically an arthroscope, with a large depth of field (DOF). The incident heights and exit angles of the sampled rays on the relay lens are controlled during the optimization process to ensure an effective field view (70°) and a normal ray path within the limited lens diameter of 2.7 mm. The lens is set up as a multi-configuration system with two extreme and one middle object distances to cover a large DOF. As a result, an entrance pupil of 0.3 mm is achieved for the first time, to bring the theoretical resolution to 23.1 lps/mm in the object space at a working distance of 20 mm, with the wavelength of 0.532 um. The modulation transfer function (MTF) curves approach diffraction limit, and the values are all higher than 0.3 at 160 line pairs/mm (lps/mm) in the image space. Meanwhile, stray light caused by total internal reflection on the inner wall of the rod lenses and the objective lens is eliminated. The measured resolution in the object space at a 20 mm working distance is 22.3 lps/mm, and test results show that other performance characteristics also fulfill design requirements. The relay lenses are designed with only one type of the spacer and two types of lenses to greatly reduce the fabrication and assembly cost. The design method has important research and application values for lens systems used in modern minimally invasive medical surgery and industrial non-destructive testing area.

  1. Optimized computational imaging methods for small-target sensing in lens-free holographic microscopy

    NASA Astrophysics Data System (ADS)

    Xiong, Zhen; Engle, Isaiah; Garan, Jacob; Melzer, Jeffrey E.; McLeod, Euan

    2018-02-01

    Lens-free holographic microscopy is a promising diagnostic approach because it is cost-effective, compact, and suitable for point-of-care applications, while providing high resolution together with an ultra-large field-of-view. It has been applied to biomedical sensing, where larger targets like eukaryotic cells, bacteria, or viruses can be directly imaged without labels, and smaller targets like proteins or DNA strands can be detected via scattering labels like micro- or nano-spheres. Automated image processing routines can count objects and infer target concentrations. In these sensing applications, sensitivity and specificity are critically affected by image resolution and signal-to-noise ratio (SNR). Pixel super-resolution approaches have been shown to boost resolution and SNR by synthesizing a high-resolution image from multiple, partially redundant, low-resolution images. However, there are several computational methods that can be used to synthesize the high-resolution image, and previously, it has been unclear which methods work best for the particular case of small-particle sensing. Here, we quantify the SNR achieved in small-particle sensing using regularized gradient-descent optimization method, where the regularization is based on cardinal-neighbor differences, Bayer-pattern noise reduction, or sparsity in the image. In particular, we find that gradient-descent with sparsity-based regularization works best for small-particle sensing. These computational approaches were evaluated on images acquired using a lens-free microscope that we assembled from an off-the-shelf LED array and color image sensor. Compared to other lens-free imaging systems, our hardware integration, calibration, and sample preparation are particularly simple. We believe our results will help to enable the best performance in lens-free holographic sensing.

  2. Evaluation of lens distortion errors in video-based motion analysis

    NASA Technical Reports Server (NTRS)

    Poliner, Jeffrey; Wilmington, Robert; Klute, Glenn K.; Micocci, Angelo

    1993-01-01

    In an effort to study lens distortion errors, a grid of points of known dimensions was constructed and videotaped using a standard and a wide-angle lens. Recorded images were played back on a VCR and stored on a personal computer. Using these stored images, two experiments were conducted. Errors were calculated as the difference in distance from the known coordinates of the points to the calculated coordinates. The purposes of this project were as follows: (1) to develop the methodology to evaluate errors introduced by lens distortion; (2) to quantify and compare errors introduced by use of both a 'standard' and a wide-angle lens; (3) to investigate techniques to minimize lens-induced errors; and (4) to determine the most effective use of calibration points when using a wide-angle lens with a significant amount of distortion. It was seen that when using a wide-angle lens, errors from lens distortion could be as high as 10 percent of the size of the entire field of view. Even with a standard lens, there was a small amount of lens distortion. It was also found that the choice of calibration points influenced the lens distortion error. By properly selecting the calibration points and avoidance of the outermost regions of a wide-angle lens, the error from lens distortion can be kept below approximately 0.5 percent with a standard lens and 1.5 percent with a wide-angle lens.

  3. The effect of lens-induced anisometropia on accommodation and vergence during human visual development.

    PubMed

    Bharadwaj, Shrikant R; Candy, T Rowan

    2011-06-01

    Clear and single binocular vision, a prerequisite for normal human visual development, is achieved through accommodation and vergence. Anisometropia is associated with abnormal visual development, but its impact on accommodation and vergence, and therefore on the individual's visual experience, is not known. This study determined the impact of transiently induced anisometropia on accommodative and vergence performance of the typically developing human visual system. One hundred eighteen subjects (age range, 2.9 months to 41.1 years) watched a cartoon movie that moved between 80 and 33 cm under six different viewing conditions: binocular and monocular, and with ±2 diopters (D) and ±4 D of lens-induced anisometropia. Twenty-one subjects (age range, 3.1 months to 12.1 years) also watched the movie with 11% induced aniseikonia. Accommodation and vergence were recorded in both eyes using a videoretinoscope (25 Hz). The main effect of viewing condition was statistically significant for both accommodation and vergence (both P < 0.001), with monocular accommodative and vergence gains statistically significantly smaller than the binocular and four induced anisometropia conditions (P < 0.001 for both accommodation and vergence). The main effect of age approached significance for accommodation (P = 0.06) and was not significant for vergence (P = 0.32). Accommodative and vergence gains with induced aniseikonia were not statistically significantly different from the binocular condition (both P > 0.5). Accommodative and vergence gains of the typically developing visual system deteriorated marginally (accommodation more than vergence) with transiently induced anisometropia (up to ±4 D) and did not deteriorate significantly with induced aniseikonia of 11%. Some binocular cues remained with ±4 D of induced anisometropia and 11% induced aniseikonia, as indicated by the accommodative and vergence gains being higher than in monocular viewing.

  4. Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

    PubMed

    Pérez-Vives, Cari; Domínguez-Vicent, Alberto; Madrid-Costa, David; Ferrer-Blasco, Teresa; Montés-Micó, Robert

    2013-03-01

    To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree(-1) were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. At a 3-mm pupil we only found statistically significant differences in VA between the two simulated surgeries at low-contrast for moderate- and high-myopic astigmatism (p < 0.05). Statistically significant differences were found in CS at 3-mm pupil between both procedures at the highest spatial frequency for moderate-myopic astigmatism and at all frequencies for high-myopic astigmatism (p < 0.05). At a 5-mm pupil we found statistically significant differences in VA and CS between both simulated surgeries at all contrasts and frequencies evaluated for both groups (p < 0.05). In all cases VA and CS were better with the TICL than with the bioptics technique. MTFs for the bioptics technique were worse than those computed for the TICL. The TICL showed less spread out of the PSF than the bioptics procedure. Simulated TICL and bioptics procedures provided good optical and visual quality, although TICL implantation provided slightly better outcomes than the bioptics procedure, especially when the pupil diameter was increased. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  5. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  6. Predicting weak lensing statistics from halo mass reconstructions - Final Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Everett, Spencer

    2015-08-20

    As dark matter does not absorb or emit light, its distribution in the universe must be inferred through indirect effects such as the gravitational lensing of distant galaxies. While most sources are only weakly lensed, the systematic alignment of background galaxies around a foreground lens can constrain the mass of the lens which is largely in the form of dark matter. In this paper, I have implemented a framework to reconstruct all of the mass along lines of sight using a best-case dark matter halo model in which the halo mass is known. This framework is then used to makemore » predictions of the weak lensing of 3,240 generated source galaxies through a 324 arcmin² field of the Millennium Simulation. The lensed source ellipticities are characterized by the ellipticity-ellipticity and galaxy-mass correlation functions and compared to the same statistic for the intrinsic and ray-traced ellipticities. In the ellipticity-ellipticity correlation function, I and that the framework systematically under predicts the shear power by an average factor of 2.2 and fails to capture correlation from dark matter structure at scales larger than 1 arcminute. The model predicted galaxy-mass correlation function is in agreement with the ray-traced statistic from scales 0.2 to 0.7 arcminutes, but systematically underpredicts shear power at scales larger than 0.7 arcminutes by an average factor of 1.2. Optimization of the framework code has reduced the mean CPU time per lensing prediction by 70% to 24 ± 5 ms. Physical and computational shortcomings of the framework are discussed, as well as potential improvements for upcoming work.« less

  7. The Effect of Lens-Induced Anisometropia on Accommodation and Vergence during Human Visual Development

    PubMed Central

    Candy, T. Rowan

    2011-01-01

    Purpose. Clear and single binocular vision, a prerequisite for normal human visual development, is achieved through accommodation and vergence. Anisometropia is associated with abnormal visual development, but its impact on accommodation and vergence, and therefore on the individual's visual experience, is not known. This study determined the impact of transiently induced anisometropia on accommodative and vergence performance of the typically developing human visual system. Methods. One hundred eighteen subjects (age range, 2.9 months to 41.1 years) watched a cartoon movie that moved between 80 and 33 cm under six different viewing conditions: binocular and monocular, and with ±2 diopters (D) and ±4 D of lens-induced anisometropia. Twenty-one subjects (age range, 3.1 months to 12.1 years) also watched the movie with 11% induced aniseikonia. Accommodation and vergence were recorded in both eyes using a videoretinoscope (25 Hz). Results. The main effect of viewing condition was statistically significant for both accommodation and vergence (both P < 0.001), with monocular accommodative and vergence gains statistically significantly smaller than the binocular and four induced anisometropia conditions (P < 0.001 for both accommodation and vergence). The main effect of age approached significance for accommodation (P = 0.06) and was not significant for vergence (P = 0.32). Accommodative and vergence gains with induced aniseikonia were not statistically significantly different from the binocular condition (both P > 0.5). Conclusions. Accommodative and vergence gains of the typically developing visual system deteriorated marginally (accommodation more than vergence) with transiently induced anisometropia (up to ±4 D) and did not deteriorate significantly with induced aniseikonia of 11%. Some binocular cues remained with ±4 D of induced anisometropia and 11% induced aniseikonia, as indicated by the accommodative and vergence gains being higher than in monocular viewing. PMID:21296822

  8. Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

    PubMed

    Dong, Jing; Zhang, Yaqin; Zhang, Haining; Jia, Zhijie; Zhang, Suhua; Wang, Xiaogang

    2018-01-01

    To compare the axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOLP) of IOLMaster and Ultrasound in normal, long and short eyes. Seventy-four normal eyes (≥ 22 mm and ≤ 25 mm), 74 long eyes (> 25 mm) and 78 short eyes (< 22 mm) underwent AL and ACD measurements with both devices in the order of IOLMaster followed by Ultrasound. The IOLP were calculated using a free online LADAS IOL formula calculator. The difference in AL and IOLP between IOLMaster and Ultrasound was statistically significant when all three groups were combined. The difference in ACD between IOLMaster and Ultrasound was statistically significant in the normal group (P<0.001) and short eye group (P<0.001) but not the long eye group (P = 0.465). For the IOLP difference between IOLMaster and Ultrasound in the normal group, the percentage of IOLP differences <|0.5|D, ≥|0.5|D<|0.75|D, ≥|0.75|D<|1.0|D, and ≥|1.0|D were 90.5%, 8.1%, 1.4% and 0%, respectively. For the long eye group, they were 90.5%, 5.4%, 4.1% and 0%, respectively. For the short eye group, they were 61.5%, 23.1%, 10.3%, and 5.1%, respectively. IOLMaster and Ultrasound have statistically significant differences in AL measurements and IOLP (using LADAS formula) for normal, long eye and short eye. The two instruments agree regarding ACD measurements for the long eye group, but differ for the normal and short eye groups. Moreover, the high percentage of IOLP differences greater than |0.5|D in the short eye group is noteworthy.

  9. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    PubMed

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P < .001) and lens position (r = 0.371, P < .001), but negatively correlated with lens thickness (r = -0.262, P < .001). Eyes with vaults of less than 250 µm had shallower anterior chambers, thicker lenses, and smaller lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P < .001). Eyes with both anterior chamber depth less than 3.1 mm and lens position less than 5.1 mm had greatly reduced vaults (P < .001). The crystalline lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  10. The Microstructure Evolution of a Fe₃Al Alloy during the LENS Process.

    PubMed

    Karczewski, Krzysztof; Durejko, Tomasz; Czujko, Tomasz

    2018-03-07

    A Fe₃Al intermetallic alloy has been successfully prepared by the laser-engineered net shaping (LENS) process. The applied process parameters were selected to provide various cooling rates during the solidification of the laser-melted material. The macro- and microstructure and the micro- and macrotexture of Fe₃Al samples were investigated. The influence of the cooling rate on grain morphology and texture is discussed. For the applied cooling rate range of 0.64 × 10⁴ K/s-2.6 × 10⁴ K/s, the structure is characterized by the presence of columnar grains for which the growth is directed upwards from the substrate. The intensity of the microtexture varies with the height of the sample and the cooling rate. The intensity of the texture increases with the decrease in the cooling rate. The samples that were obtained with low and medium cooling rates are characterized by the well-developed <100> and <111> macrotextures. The Fe₃Al alloy that was produced with a high cooling rate did not show a specific texture, which is reflected in the fairly uniform distribution of the normalized density intensity. Only a very weak texture with a <100> type component was observed.

  11. Viewing Low-Income Fathers’ Ties to Families through a Cultural Lens: Insights for Research and Policy

    PubMed Central

    WALLER, MAUREEN R.

    2011-01-01

    Policy makers have become increasingly interested in addressing the cultural dimensions of child support, “responsible fatherhood,” and marriage in poor communities. However, policy studies have primarily focused on identifying economic determinants of these issues, with a substantial amount of variation in their statistical models left unexplained. This article draws on in-depth interviews the author conducted with disadvantaged mothers and fathers to illustrate how a systematic investigation into the meaning of low-income men’s ties to families may fill in or provide alternative explanations for some important questions related to paternal involvement. In particular, it suggests that analyzing fathers’ relationships through a cultural lens may not only reveal new information about the meaning of their emotional involvement, informal support, care of children, and conflicts with mothers which future policy studies should consider but may also inform policy initiatives by reducing the risk that they will be misdirected or have unintended consequences for poor families. PMID:21625346

  12. Simulation of Ametropic Human Eyes

    NASA Astrophysics Data System (ADS)

    Tan, Bo; Chen, Ying-Ling; Lewis, James W. L.

    2004-11-01

    The computational simulation of the performance of human eyes is complex because the optical parameters of the eye depend on many factors, including age, gender, race, refractive status (accommodation and near- or far-sightedness). This task is made more difficult by the inadequacy of the population statistical characteristics of these parameters. Previously we simulated ametropic (near- or far-sighted) eyes using three independent variables: the axial length of the eye, the corneal surface curvature, and the intraocular refractive index gradient. The prescription for the correction of an ametropic eye is determined by its second-order coefficients of the wavefront aberrations. These corrections are typically achieved using contact lens, spectacle lens, or laser surgery (LASIK). However, the higher order aberrations, which are not corrected and are likely complicated or enhanced by the lower-order correction, could be important for visual performance in a darkened environment. In this paper, we investigate the higher order wavefront aberrations of synthetic ametropic eyes and compare results with measured data published in the past decade. The behavior of three types of ametropes is discussed.

  13. Meridional Modes and Increasing Pacific Decadal Variability Under Anthropogenic Forcing

    NASA Astrophysics Data System (ADS)

    Liguori, Giovanni; Di Lorenzo, Emanuele

    2018-01-01

    Pacific decadal variability has strong impacts on the statistics of weather, atmosphere extremes, droughts, hurricanes, marine heatwaves, and marine ecosystems. Sea surface temperature (SST) observations show that the variance of the El Niño-like decadal variability has increased by 30% (1920-2015) with a stronger coupling between the major Pacific climate modes. Although we cannot attribute these trends to global climate change, the examination of 30 members of the Community Earth System Model Large Ensemble (LENS) forced with the RCP8.5 radiative forcing scenario (1920-2100) suggests that significant anthropogenic trends in Pacific decadal variance will emerge by 2020 in response to a more energetic North Pacific Meridional Mode (PMM)—a well-known El Niño precursor. The PMM is a key mechanism for energizing and coupling tropical and extratropical decadal variability. In the LENS, the increase in PMM variance is consistent with an intensification of the winds-evaporation-SST thermodynamic feedback that results from a warmer mean climate.

  14. Analysing news media coverage of the 2015 Nepal earthquake using a community capitals lens: implications for disaster resilience.

    PubMed

    Dhakal, Subas P

    2018-04-01

    South Asia is one of the regions of the world most vulnerable to natural disasters. Although news media analyses of disasters have been conducted frequently in various settings globally, there is little research on populous South Asia. This paper begins to fill this gap by evaluating local and foreign news media coverage of the earthquake in Nepal on 25 April 2015. It broadens the examination of news media coverage of disaster response beyond traditional framing theory, utilising community capitals (built, cultural, financial, human, natural, political, and social) lens to perform a thematic content analysis of 405 news items. Overall, financial and natural capital received the most and the least emphasis respectively. Statistically significant differences between local and foreign news media were detected vis-à-vis built, financial, and political capital. The paper concludes with a discussion of the social utility of news media analysis using the community capitals framework to inform disaster resilience. © 2018 The Author(s). Disasters © Overseas Development Institute, 2018.

  15. Selenium in soils of the Lower Wasatch Formation, Campbell County, Wyoming: Geochemistry, distribution, and environmental hazards

    NASA Technical Reports Server (NTRS)

    Kolm, K. E.

    1975-01-01

    The author has identified the following significant results. Seleniferous Shingle series soils and sandstone outcrops of section 27, T 48 N, R 71 W, Wyoming are mapped on aerial photography by their association with Astragalus bisulcatus. Chemical leachate analyses and atomic absorption methods reveal all studied Samsil and Shingle soils to contain acid, base, and water soluble selenium compounds, and that water extractions showed varied concentration behavior due to soil pH. Acid-soluble selenium is found to be associated with smectite. Statistical analyses confirm that A. bisulcatus presence has a weak influence on soil-lens organic selenium concentration, and determine the importance of other geobotanical factors for convertor presence. Environmental procedures of high selenium lens burial, convertor plant eradication, and revegetated site monitoring are recommended. Usage of density analysis and photographic enlargement are used to successfully produce both a control area and a Campbell County, Wyoming regional map of A. bisulcatus supportive soils and outcrops using Skylab photography.

  16. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters†.

    PubMed

    Sanchez, R M; Vano, E; Fernandez, J M; Ginjaume, M; Duch, M A

    2014-12-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of -15 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was -9 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Plasticity for axolotl lens regeneration is associated with age‐related changes in gene expression

    PubMed Central

    Sousounis, Konstantinos; Athippozhy, Antony T.; Voss, S. Randal

    2014-01-01

    Abstract Mexican axolotls lose potential for lens regeneration 2 weeks after hatching. We used microarrays to identify differently expressed genes before and after this critical time, using RNA isolated from iris. Over 3700 genes were identified as differentially expressed in response to lentectomy between young (7 days post‐hatching) and old (3 months post‐hatching) axolotl larvae. Strikingly, many of the genes were only expressed in the early or late iris. Genes that were highly expressed in young iris significantly enriched electron transport chain, transcription, metabolism, and cell cycle gene ontologies, all of which are associated with lens regeneration. In contrast, genes associated with cellular differentiation and tissue maturation were uniquely expressed in old iris. Many of these expression differences strongly suggest that young and old iris samples were collected before and after the spleen became developmentally competent to produce and secrete cells with humoral and innate immunity functions. Our study establishes the axolotl as a powerful model to investigate age‐related cellular differentiation and immune system ontogeny within the context of tissue regeneration. PMID:27499863

  18. Focused Heavy Ion Nuclear Microprobe facility at the University of North Texas

    NASA Astrophysics Data System (ADS)

    Guo, B. N.; Yang, C.; El Bouanani, M.; Duggan, J. L.; McDaniel, F. D.

    1999-10-01

    A Focused Heavy Ion Nuclear Microprobe facility has been constructed at the University of North Texas. The microprobe utilizes two separated Russian magnetic quadrupole quadruplets. The two identical magnetic quadrupole doublet lenses are separated by 2.61 meters. The lens system with ~ 80 times demagnification has the ability to focus proton, alpha particle, or heavier ions down to a spot size of ~ 1 μm. The microprobe components rest on a 7 meter steel beam support with vibration isolation. A computer provides control for the lens power supplies and also the parameters for a post-lens scanning coil to raster-scan the beam across the sample. Up to four detection channels can be used for simultaneous data acquisition under VME control. A RISC workstation is used to collect, display and analyze the data. The data is transferred via ethernet. A detailed description of the facility and data acquisition system along with preliminary testing results on TEM grids with Rutherford Backscattering Spectrometry and the Ion Beam Induced Charge Collection techniques will be presented.

  19. Aqueous Humor Penetration and Biological Activity of Moxifloxacin 0.5% Ophthalmic Solution Alone or with Dexamethasone 0.1.

    PubMed

    Gomes, Rachel L R; Viana, Rodrigo Galvão; Melo, Luiz Alberto S; Cruz, Alessandro Carvalho; Suenaga, Eunice Mayumi; Kenyon, Kenneth R; Campos, Mauro

    2017-03-01

    To compare aqueous humor concentrations of topically applied moxifloxacin 0.5% ophthalmic solution alone or in combination with dexamethasone 0.1% and to correlate these concentrations with the minimum inhibitory concentrations (MICs) for common endophthalmitis-causing organisms. Sixty-eight patients undergoing routine phacoemulsification with intraocular lens implantation received either moxifloxacin 0.5% alone or moxifloxacin 0.5% combined with dexamethasone. For both groups, 1 drop of the test solution was instilled 4 times daily 1 day preoperatively and 1 drop 1 h preoperatively. An aqueous humor sample obtained immediately before paracentesis was submitted to high-performance liquid chromatography-tandem mass spectrometry to determine the moxifloxacin concentration. The mean concentrations of moxifloxacin were 986.6 ng/mL in the moxifloxacin with dexamethasone group and 741.3 ng/mL in the moxifloxacin group (P = 0.13). Moxifloxacin concentrations of all samples exceeded the MICs for Staphylococcus epidermidis, S. aureus, and Streptococcus pneumoniae. All samples in the moxifloxacin with dexamethasone group and 94% in the moxifloxacin group achieved the MIC for Enterococcus species. For quinolone-resistant S. aureus, the MIC was achieved in 29% in the moxifloxacin with dexamethasone group and 9% in the moxifloxacin group (P = 0.06). Aqueous humor moxifloxacin concentrations were higher when topically administrated in combination with dexamethasone compared to the moxifloxacin alone. However, this difference was not statistically significant. Nevertheless, the MICs of the most common pathogens associated with endophthalmitis were exceeded in both study groups.

  20. Differential phase acoustic microscope for micro-NDE

    NASA Technical Reports Server (NTRS)

    Waters, David D.; Pusateri, T. L.; Huang, S. R.

    1992-01-01

    A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.

Top