Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J
2015-06-01
This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.
Lee, F K-H; Chan, C C-L; Law, C-K
2009-02-01
Contrast enhanced computed tomography (CECT) has been used for delineation of treatment target in radiotherapy. The different Hounsfield unit due to the injected contrast agent may affect radiation dose calculation. We investigated this effect on intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC). Dose distributions of 15 IMRT plans were recalculated on CECT. Dose statistics for organs at risk (OAR) and treatment targets were recorded for the plain CT-calculated and CECT-calculated plans. Statistical significance of the differences was evaluated. Correlations were also tested, among magnitude of calculated dose difference, tumor size and level of enhancement contrast. Differences in nodal mean/median dose were statistically significant, but small (approximately 0.15 Gy for a 66 Gy prescription). In the vicinity of the carotid arteries, the difference in calculated dose was also statistically significant, but only with a mean of approximately 0.2 Gy. We did not observe any significant correlation between the difference in the calculated dose and the tumor size or level of enhancement. The results implied that the calculated dose difference was clinically insignificant and may be acceptable for IMRT planning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Power, S.; Mirza, M.; Thakorlal, A.
PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used tomore » measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.« less
The choice of statistical methods for comparisons of dosimetric data in radiotherapy.
Chaikh, Abdulhamid; Giraud, Jean-Yves; Perrin, Emmanuel; Bresciani, Jean-Pierre; Balosso, Jacques
2014-09-18
Novel irradiation techniques are continuously introduced in radiotherapy to optimize the accuracy, the security and the clinical outcome of treatments. These changes could raise the question of discontinuity in dosimetric presentation and the subsequent need for practice adjustments in case of significant modifications. This study proposes a comprehensive approach to compare different techniques and tests whether their respective dose calculation algorithms give rise to statistically significant differences in the treatment doses for the patient. Statistical investigation principles are presented in the framework of a clinical example based on 62 fields of radiotherapy for lung cancer. The delivered doses in monitor units were calculated using three different dose calculation methods: the reference method accounts the dose without tissues density corrections using Pencil Beam Convolution (PBC) algorithm, whereas new methods calculate the dose with tissues density correction for 1D and 3D using Modified Batho (MB) method and Equivalent Tissue air ratio (ETAR) method, respectively. The normality of the data and the homogeneity of variance between groups were tested using Shapiro-Wilks and Levene test, respectively, then non-parametric statistical tests were performed. Specifically, the dose means estimated by the different calculation methods were compared using Friedman's test and Wilcoxon signed-rank test. In addition, the correlation between the doses calculated by the three methods was assessed using Spearman's rank and Kendall's rank tests. The Friedman's test showed a significant effect on the calculation method for the delivered dose of lung cancer patients (p <0.001). The density correction methods yielded to lower doses as compared to PBC by on average (-5 ± 4.4 SD) for MB and (-4.7 ± 5 SD) for ETAR. Post-hoc Wilcoxon signed-rank test of paired comparisons indicated that the delivered dose was significantly reduced using density-corrected methods as compared to the reference method. Spearman's and Kendall's rank tests indicated a positive correlation between the doses calculated with the different methods. This paper illustrates and justifies the use of statistical tests and graphical representations for dosimetric comparisons in radiotherapy. The statistical analysis shows the significance of dose differences resulting from two or more techniques in radiotherapy.
Tran, Van; Little, Mark P
2017-11-01
Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and non-malignant, show downward curvature in the dose response, and for most endpoints this is statistically significant (p < 0.05). Associated with this, the low-dose extrapolation factor associated with neutron exposure is generally statistically significantly less than 1 for most malignant and non-malignant endpoints, with central estimates mostly in the range 0.1-0.9. In contrast to the situation at higher dose rates, there are statistically non-significant decreases of risk per unit dose at gamma dose rates of less than or equal to 5 mGy/h for most malignant endpoints, and generally non-significant increases in risk per unit dose at gamma dose rates ≤5 mGy/h for most non-malignant endpoints. Associated with this, the dose-rate extrapolation factor, the ratio of high dose-rate to low dose-rate (≤5 mGy/h) gamma dose response slopes, for many tumour sites is in the range 1.2-2.3, albeit not statistically significantly elevated from 1, while for most non-malignant endpoints the gamma dose-rate extrapolation factor is less than 1, with most estimates in the range 0.2-0.8. After neutron exposure there are non-significant indications of lower risk per unit dose at dose rates ≤5 mGy/h compared to higher dose rates for most malignant endpoints, and for all tumours (p = 0.001), and respiratory tumours (p = 0.007) this reduction is conventionally statistically significant; for most non-malignant outcomes risks per unit dose non-significantly increase at lower dose rates. Associated with this, the neutron dose-rate extrapolation factor is less than 1 for most malignant and non-malignant endpoints, in many cases statistically significantly so, with central estimates mostly in the range 0.0-0.2.
Gaylor, David W; Lutz, Werner K; Conolly, Rory B
2004-01-01
Statistical analyses of nonmonotonic dose-response curves are proposed, experimental designs to detect low-dose effects of J-shaped curves are suggested, and sample sizes are provided. For quantal data such as cancer incidence rates, much larger numbers of animals are required than for continuous data such as biomarker measurements. For example, 155 animals per dose group are required to have at least an 80% chance of detecting a decrease from a 20% incidence in controls to an incidence of 10% at a low dose. For a continuous measurement, only 14 animals per group are required to have at least an 80% chance of detecting a change of the mean by one standard deviation of the control group. Experimental designs based on three dose groups plus controls are discussed to detect nonmonotonicity or to estimate the zero equivalent dose (ZED), i.e., the dose that produces a response equal to the average response in the controls. Cell proliferation data in the nasal respiratory epithelium of rats exposed to formaldehyde by inhalation are used to illustrate the statistical procedures. Statistically significant departures from a monotonic dose response were obtained for time-weighted average labeling indices with an estimated ZED at a formaldehyde dose of 5.4 ppm, with a lower 95% confidence limit of 2.7 ppm. It is concluded that demonstration of a statistically significant bi-phasic dose-response curve, together with estimation of the resulting ZED, could serve as a point-of departure in establishing a reference dose for low-dose risk assessment.
Ordiales, J M; Nogales, J M; Vano, E; López-Mínguez, J R; Alvarez, F J; Ramos, J; Martínez, G; Sánchez, R M
2017-04-25
The aim of this study was to evaluate the occupational radiation dose in interventional cardiology by using a shielding drape on the patient. A random study with and without the protective material was conducted. The following control parameters were registered: demographic data, number of stents, contrast media volume, fluoroscopy time, number of cine images, kerma-area product and cumulative air kerma. Occupational dose data were obtained by electronic active dosemeters. No statistically significant differences in the analysed control parameters were registered. The median dose value received by the interventional cardiologist was 50% lower in the group with a shielding drape with a statistically significant p-value <0.001. In addition, the median value of the maximum scatter radiation dose was 31% lower in this group with a statistically significant p-value <0.001. This study showed that a shielding drape is a useful tool for reducing the occupational radiation dose in a cardiac catheterisation laboratory. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Best, R; Harrell, A; Geesey, C
2014-06-15
Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parametersmore » of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.« less
Widmann, Gerlig; Schullian, Peter; Gassner, Eva-Maria; Hoermann, Romed; Bale, Reto; Puelacher, Wolfgang
2015-03-01
OBJECTIVE. The purpose of this article is to evaluate 2D and 3D image quality of high-resolution ultralow-dose CT images of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard filtered backprojection (FBP). MATERIALS AND METHODS. A formalin-fixed human cadaver head was scanned using a clinical reference protocol at a CT dose index volume of 30.48 mGy and a series of five ultralow-dose protocols at 3.48, 2.19, 0.82, 0.44, and 0.22 mGy using FBP and ASIR at 50% (ASIR-50), ASIR at 100% (ASIR-100), and MBIR. Blinded 2D axial and 3D volume-rendered images were compared with each other by three readers using top-down scoring. Scores were analyzed per protocol or dose and reconstruction. All images were compared with the FBP reference at 30.48 mGy. A nonparametric Mann-Whitney U test was used. Statistical significance was set at p < 0.05. RESULTS. For 2D images, the FBP reference at 30.48 mGy did not statistically significantly differ from ASIR-100 at 3.48 mGy, ASIR-100 at 2.19 mGy, and MBIR at 0.82 mGy. MBIR at 2.19 and 3.48 mGy scored statistically significantly better than the FBP reference (p = 0.032 and 0.001, respectively). For 3D images, the FBP reference at 30.48 mGy did not statistically significantly differ from all reconstructions at 3.48 mGy; FBP and ASIR-100 at 2.19 mGy; FBP, ASIR-100, and MBIR at 0.82 mGy; MBIR at 0.44 mGy; and MBIR at 0.22 mGy. CONCLUSION. MBIR (2D and 3D) and ASIR-100 (2D) may significantly improve subjective image quality of ultralow-dose images and may allow more than 90% dose reductions.
NASA Astrophysics Data System (ADS)
Lee, Richard; Chan, Elisa K.; Kosztyla, Robert; Liu, Mitchell; Moiseenko, Vitali
2012-12-01
The relationship between rectal dose distribution and the incidence of late rectal complications following external-beam radiotherapy has been previously studied using dose-volume histograms or dose-surface histograms. However, they do not account for the spatial dose distribution. This study proposes a metric based on both surface dose and distance that can predict the incidence of rectal bleeding in prostate cancer patients treated with radical radiotherapy. One hundred and forty-four patients treated with radical radiotherapy for prostate cancer were prospectively followed to record the incidence of grade ≥2 rectal bleeding. Radiotherapy plans were used to evaluate a dose-distance metric that accounts for the dose and its spatial distribution on the rectal surface, characterized by a logistic weighting function with slope a and inflection point d0. This was compared to the effective dose obtained from dose-surface histograms, characterized by the parameter n which describes sensitivity to hot spots. The log-rank test was used to determine statistically significant (p < 0.05) cut-off values for the dose-distance metric and effective dose that predict for the occurrence of rectal bleeding. For the dose-distance metric, only d0 = 25 and 30 mm combined with a > 5 led to statistical significant cut-offs. For the effective dose metric, only values of n in the range 0.07-0.35 led to statistically significant cut-offs. The proposed dose-distance metric is a predictor of rectal bleeding in prostate cancer patients treated with radiotherapy. Both the dose-distance metric and the effective dose metric indicate that the incidence of grade ≥2 rectal bleeding is sensitive to localized damage to the rectal surface.
Naidu, Sailen G; Kriegshauser, J Scott; Paden, Robert G; He, Miao; Wu, Qing; Hara, Amy K
2014-12-01
An ultra-low-dose radiation protocol reconstructed with model-based iterative reconstruction was compared with our standard-dose protocol. This prospective study evaluated 20 men undergoing surveillance-enhanced computed tomography after endovascular aneurysm repair. All patients underwent standard-dose and ultra-low-dose venous phase imaging; images were compared after reconstruction with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction. Objective measures of aortic contrast attenuation and image noise were averaged. Images were subjectively assessed (1 = worst, 5 = best) for diagnostic confidence, image noise, and vessel sharpness. Aneurysm sac diameter and endoleak detection were compared. Quantitative image noise was 26% less with ultra-low-dose model-based iterative reconstruction than with standard-dose adaptive statistical iterative reconstruction and 58% less than with ultra-low-dose adaptive statistical iterative reconstruction. Average subjective noise scores were not different between ultra-low-dose model-based iterative reconstruction and standard-dose adaptive statistical iterative reconstruction (3.8 vs. 4.0, P = .25). Subjective scores for diagnostic confidence were better with standard-dose adaptive statistical iterative reconstruction than with ultra-low-dose model-based iterative reconstruction (4.4 vs. 4.0, P = .002). Vessel sharpness was decreased with ultra-low-dose model-based iterative reconstruction compared with standard-dose adaptive statistical iterative reconstruction (3.3 vs. 4.1, P < .0001). Ultra-low-dose model-based iterative reconstruction and standard-dose adaptive statistical iterative reconstruction aneurysm sac diameters were not significantly different (4.9 vs. 4.9 cm); concordance for the presence of endoleak was 100% (P < .001). Compared with a standard-dose technique, an ultra-low-dose model-based iterative reconstruction protocol provides comparable image quality and diagnostic assessment at a 73% lower radiation dose.
Sterile Basics of Compounding: Relationship Between Syringe Size and Dosing Accuracy.
Kosinski, Tracy M; Brown, Michael C; Zavala, Pedro J
2018-01-01
The purpose of this study was to investigate the accuracy and reproducibility of a 2-mL volume injection using a 3-mL and 10-mL syringe with pharmacy student compounders. An exercise was designed to assess each student's accuracy in compounding a sterile preparation with the correct 4-mg strength using a 3-mL and 10-mL syringe. The average ondansetron dose when compounded with the 3-mL syringe was 4.03 mg (standard deviation ± 0.45 mg), which was not statistically significantly different than the intended 4-mg desired dose (P=0.497). The average ondansetron dose when compounded with the 10-mL syringe was 4.18 mg (standard deviation + 0.68 mg), which was statistically significantly different than the intended 4-mg desired dose (P=0.002). Additionally, there also was a statistically significant difference in the average ondansetron dose compounded using a 3-mL syringe (4.03 mg) and a 10-mL syringe (4.18 mg) (P=0.027). The accuracy and reproducibility of the 2-mL desired dose volume decreased as the compounding syringe size increased from 3 mL to 10 mL. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Marciniak, B; Lopaczyńska, D; Kowalczyk, E; Skośkiewicz, J; Witczak, M; Majczyk, M; Grabowicz, W; Ferenc, T
2013-03-01
α-Amanitin, the main toxic substance from mushroom species (Amanita genus), blocks the activity of RNA polymerase II (Pol II) in mammalian cells causing inhibition of transcription and subsequent synthesis of structural and enzymatic proteins. It has been postulated that α-amanitin generates the increase of reactive oxygen species (ROS) concentration. The micronucleus (MN) test was used on an animal experimental model to evaluate possible potential genotoxic effect of α-amanitin on mice bone marrow cells. At the same time the activity of antioxidant enzymes: superoxide dismutase (SOD) and catalase (CAT) as well as concentration of thiobarbituric acid reactive substance (TBARS) were investigated in the lysate of mice erythrocytes. α-Amanitin was administered intraperitoneally at the doses: 0.1, 0.15, and 0.25 mg/kg bw (LD(50) for mice) 48 h prior to sacrification. A statistically significant increase of SOD activity was observed in the hemolysate for all the investigated α-amanitin doses as compared to the negative control (p < 0.05). CAT activity for α-amanitin doses 0.1 and 0.15 mg/kg was higher in comparison to the negative control but the differences were not statistically significant (p > 0.05). However, for the dose 0.25 mg/kg the activity of CAT was statistically significantly higher (p < 0.001). All the tested α-amanitin doses decreased TBARS concentration in the hemolysate as compared to the negative control but the differences were not statistically significant (p > 0.05). A statistically significant increase of mean values of MN percent was found in polychromatic erythrocytes (PCEs) as compared to the negative control for α-amanitin dose 0.1 and 0.25 mg/kg (p < 0.05). For the dose 0.15 mg/kg the mean value of MN percent was higher but it did not demonstrate statistical significance (p > 0.1). The observed disturbances in the activity of the examined antioxidant enzymes in cells exposed in vivo to α-amanitin suggest indirect genotoxic effect of α-amanitin through ROS generation. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Little, Mark P., E-mail: mark.little@nih.gov; Stovall, Marilyn; Smith, Susan A.
Purpose: To assess the shape of the dose response for various cancer endpoints and modifiers by age and time. Methods and Materials: Reanalysis of the US peptic ulcer data testing for heterogeneity of radiogenic risk by cancer endpoint (stomach, pancreas, lung, leukemia, all other). Results: There are statistically significant (P<.05) excess risks for all cancer and for lung cancer and borderline statistically significant risks for stomach cancer (P=.07), and leukemia (P=.06), with excess relative risks Gy{sup -1} of 0.024 (95% confidence interval [CI] 0.011, 0.039), 0.559 (95% CI 0.221, 1.021), 0.042 (95% CI -0.002, 0.119), and 1.087 (95% CI -0.018,more » 4.925), respectively. There is statistically significant (P=.007) excess risk of pancreatic cancer when adjusted for dose-response curvature. General downward curvature is apparent in the dose response, statistically significant (P<.05) for all cancers, pancreatic cancer, and all other cancers (ie, other than stomach, pancreas, lung, leukemia). There are indications of reduction in relative risk with increasing age at exposure (for all cancers, pancreatic cancer), but no evidence for quadratic variations in relative risk with age at exposure. If a linear-exponential dose response is used, there is no significant heterogeneity in the dose response among the 5 endpoints considered or in the speed of variation of relative risk with age at exposure. The risks are generally consistent with those observed in the Japanese atomic bomb survivors and in groups of nuclear workers. Conclusions: There are excess risks for various malignancies in this data set. Generally there is a marked downward curvature in the dose response and significant reduction in relative risk with increasing age at exposure. The consistency of risks with those observed in the Japanese atomic bomb survivors and in groups of nuclear workers implies that there may be little sparing effect of fractionation of dose or low-dose-rate exposure.« less
Wang, Shiying; Herbst, Elizabeth B.; Mauldin, F. William; Diakova, Galina B.; Klibanov, Alexander L.; Hossack, John A.
2016-01-01
Objectives The objective of this study is to evaluate the minimum microbubble dose for ultrasound molecular imaging to achieve statistically significant detection of angiogenesis in a mouse model. Materials and Methods The pre-burst minus post-burst method was implemented on a Verasonics ultrasound research scanner using a multi-frame compounding pulse inversion imaging sequence. Biotinylated lipid (distearoyl phosphatidylcholine, DSPC-based) microbubbles that were conjugated with anti-vascular endothelial growth factor 2 (VEGFR2) antibody (MBVEGFR2) or isotype control antibody (MBControl) were injected into mice carrying adenocarcinoma xenografts. Different injection doses ranging from 5 × 104 to 1 × 107 microbubbles per mouse were evaluated to determine the minimum diagnostically effective dose. Results The proposed imaging sequence was able to achieve statistically significant detection (p < 0.05, n = 5) of VEGFR2 in tumors with a minimum MBVEGFR2 injection dose of only 5 × 104 microbubbles per mouse (DSPC at 0.053 ng/g mouse body mass). Non-specific adhesion of MBControl at the same injection dose was negligible. Additionally, the targeted contrast ultrasound signal of MBVEGFR2 decreased with lower microbubble doses, while non-specific adhesion of MBControl increased with higher microbubble doses. Conclusions 5 × 104 microbubbles per animal is now the lowest injection dose on record for ultrasound molecular imaging to achieve statistically significant detection of molecular targets in vivo. Findings in this study provide us with further guidance for future developments of clinically translatable ultrasound molecular imaging applications using a lower dose of microbubbles. PMID:27654582
Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni
2013-12-01
To evaluate dose reduction and image quality of abdominopelvic computed tomography (CT) reconstructed with model-based iterative reconstruction (MBIR) compared to adaptive statistical iterative reconstruction (ASIR). In this prospective study, 85 patients underwent referential-, low-, and ultralow-dose unenhanced abdominopelvic CT. Images were reconstructed with ASIR for low-dose (L-ASIR) and ultralow-dose CT (UL-ASIR), and with MBIR for ultralow-dose CT (UL-MBIR). Image noise was measured in the abdominal aorta and iliopsoas muscle. Subjective image analyses and a lesion detection study (adrenal nodules) were conducted by two blinded radiologists. A reference standard was established by a consensus panel of two different radiologists using referential-dose CT reconstructed with filtered back projection. Compared to low-dose CT, there was a 63% decrease in dose-length product with ultralow-dose CT. UL-MBIR had significantly lower image noise than L-ASIR and UL-ASIR (all p<0.01). UL-MBIR was significantly better for subjective image noise and streak artifacts than L-ASIR and UL-ASIR (all p<0.01). There were no significant differences between UL-MBIR and L-ASIR in diagnostic acceptability (p>0.65), or diagnostic performance for adrenal nodules (p>0.87). MBIR significantly improves image noise and streak artifacts compared to ASIR, and can achieve radiation dose reduction without severely compromising image quality.
Dose fractionation theorem in 3-D reconstruction (tomography)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glaeser, R.M.
It is commonly assumed that the large number of projections for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3-D reconstruction is the same as that required to obtain a single 2-D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3-D image can be computed from statistically insignificant projections, as along as the total dosage that is distributed among these projections is high enough that it would have resultedmore » in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3-D model created from an electron micrograph. The simulations verify the basic conclusions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Furthermore, the simulations demonstrate that individual projections in the series of fractionated-dose images can be aligned by cross-correlation because they contain significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3-D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results, in combination with dose estimates for imaging single voxels and measurements of radiation damage in the electron microscope, demonstrate that it is feasible to use single-axis tomography with soft X-ray microscopy of frozen-hydrated specimens.« less
Chen, Yongdi; Gu, Hua; Cheng, Suyun; Shen, Lingzhi; Cui, Fujiang; Wang, Fuzhen; Yao, Jun; Xia, Shichang; Lv, Huakun; Liang, Xiaofeng
2013-04-01
In the present study, we investigated the changes in both anti-HAV lgG and anti-HBs lgG levels and compared the antibody seroconversion rates of different doses of combined hepatitis A and hepatitis B vaccine in children. Children who were vaccinated as infants with Hepatitis B vaccine were revaccinated at 5-15 y of age, then the antibody titers were monitored. Among 283 children, this study found that the anti-HAV seroconversion rates (defined as anti-HAV ≥ 1 mIU/ml) after the first and the third dose were 79.9% and 100% respectively; these observed differences were statistically significant (P<0.05); the corresponding geometric mean titers (GMTs) were 4.72 ± 2.63 mIU/ml and 13.46 ± 1.16 mIU/ml respectively. The anti-HBs seroconversion rates (defined as an anti-HBs ≥ 10 mIU/ml) were 82.3% and 99.0% respectively; these observed differences were statistically significant (P<0.05); and the corresponding titers were 319.95 ± 5.16 mIU/ml and 418.59 ± 3.89 mIU/ml respectively. After the first booster dose, the difference in anti-HAV seroconversion rate was statistically significant in children aged 5-9 y and 10-15 y (P<0.05), as was the difference of anti-HBs seroconversion, whereas after the third dose the difference was not statistically significant (P>0.05). This study demonstrated that the immunization effects of booster vaccination with combined hepatitis A and hepatitis B vaccine is successful for children. A single booster dose is adequate for younger children, while three doses are needed for older children.
Yoon, Hyun Jung; Chung, Myung Jin; Hwang, Hye Sun; Moon, Jung Won; Lee, Kyung Soo
2015-01-01
To assess the performance of adaptive statistical iterative reconstruction (ASIR)-applied ultra-low-dose CT (ULDCT) in detecting small lung nodules. Thirty patients underwent both ULDCT and standard dose CT (SCT). After determining the reference standard nodules, five observers, blinded to the reference standard reading results, independently evaluated SCT and both subsets of ASIR- and filtered back projection (FBP)-driven ULDCT images. Data assessed by observers were compared statistically. Converted effective doses in SCT and ULDCT were 2.81 ± 0.92 and 0.17 ± 0.02 mSv, respectively. A total of 114 lung nodules were detected on SCT as a standard reference. There was no statistically significant difference in sensitivity between ASIR-driven ULDCT and SCT for three out of the five observers (p = 0.678, 0.735, < 0.01, 0.038, and < 0.868 for observers 1, 2, 3, 4, and 5, respectively). The sensitivity of FBP-driven ULDCT was significantly lower than that of ASIR-driven ULDCT in three out of the five observers (p < 0.01 for three observers, and p = 0.064 and 0.146 for two observers). In jackknife alternative free-response receiver operating characteristic analysis, the mean values of figure-of-merit (FOM) for FBP, ASIR-driven ULDCT, and SCT were 0.682, 0.772, and 0.821, respectively, and there were no significant differences in FOM values between ASIR-driven ULDCT and SCT (p = 0.11), but the FOM value of FBP-driven ULDCT was significantly lower than that of ASIR-driven ULDCT and SCT (p = 0.01 and 0.00). Adaptive statistical iterative reconstruction-driven ULDCT delivering a radiation dose of only 0.17 mSv offers acceptable sensitivity in nodule detection compared with SCT and has better performance than FBP-driven ULDCT.
Yoon, Hyun Jung; Hwang, Hye Sun; Moon, Jung Won; Lee, Kyung Soo
2015-01-01
Objective To assess the performance of adaptive statistical iterative reconstruction (ASIR)-applied ultra-low-dose CT (ULDCT) in detecting small lung nodules. Materials and Methods Thirty patients underwent both ULDCT and standard dose CT (SCT). After determining the reference standard nodules, five observers, blinded to the reference standard reading results, independently evaluated SCT and both subsets of ASIR- and filtered back projection (FBP)-driven ULDCT images. Data assessed by observers were compared statistically. Results Converted effective doses in SCT and ULDCT were 2.81 ± 0.92 and 0.17 ± 0.02 mSv, respectively. A total of 114 lung nodules were detected on SCT as a standard reference. There was no statistically significant difference in sensitivity between ASIR-driven ULDCT and SCT for three out of the five observers (p = 0.678, 0.735, < 0.01, 0.038, and < 0.868 for observers 1, 2, 3, 4, and 5, respectively). The sensitivity of FBP-driven ULDCT was significantly lower than that of ASIR-driven ULDCT in three out of the five observers (p < 0.01 for three observers, and p = 0.064 and 0.146 for two observers). In jackknife alternative free-response receiver operating characteristic analysis, the mean values of figure-of-merit (FOM) for FBP, ASIR-driven ULDCT, and SCT were 0.682, 0.772, and 0.821, respectively, and there were no significant differences in FOM values between ASIR-driven ULDCT and SCT (p = 0.11), but the FOM value of FBP-driven ULDCT was significantly lower than that of ASIR-driven ULDCT and SCT (p = 0.01 and 0.00). Conclusion Adaptive statistical iterative reconstruction-driven ULDCT delivering a radiation dose of only 0.17 mSv offers acceptable sensitivity in nodule detection compared with SCT and has better performance than FBP-driven ULDCT. PMID:26357505
Abbas, Ahmar S; Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-05-06
Recently, volumetric-modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity-modulated fixed-field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs-at-risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed-field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient-specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single-arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2-T3 N0-N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281-601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four-field (n = 4) or five-field (n = 9) step-and-shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose-volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two-arc plans. The comparison of VMATI with fixed-field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p = 0.47), PTV mean (p = 0.12), PTV D95 and PTV V9547.5Gy (95%) (p = 0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p = 0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p = 0.04). VMATI achieved lower lung V20 (p = 0.05), whereas lung V5 (p = 0.35) and mean lung dose (p = 0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p = 5.8E-10) and MUs reduced by up to 16% (p = 0.001). Integral dose was not statistically different between the two planning techniques (p = 0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p = 0.76), PTV D95 (p = 0.95), mean PTV dose (p = 0.78), conformation number (CN) (p = 0.26), and MUs (p = 0.1). However, the treatment delivery time for VMATII increased significantly by two-fold (p = 3.0E-11) compared to VMATI. VMAT-based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single-arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI.
Fernández, María Dolores; Alonso-Blázquez, María Nieves; García-Gómez, Concepción; Babin, Mar
2014-11-01
To study the environmental impact of nanoparticles, the sludges of wastewater (WWTS) and water treatment (WTS) plants enriched with ZnO nanoparticles were added to agricultural soil, and the toxic effects of the nanoparticles were studied using a microcosm system based on the soil. The WWTS treated soils were characterised by statistically significant decreases (p<0.05) in Vicia sativa germination at the lowest (76.2%) and medium (95.2%) application rates, decreases in the fresh biomass for Triticum aestivum (19.5%), Raphanus sativus (64.1%), V. sativa (37.4%) and Eisenia fetida (33.6%) at the highest application rate and a dose-related significant increase (p<0.05) in earthworm mortality. In WTS amended soils, significant reductions (p<0.05) of the fresh biomass (17.2%) and the chlorophyll index (24.4%) for T. aestivum and the fresh biomass for R. sativus (31.4%) were only recorded at the highest application doses. In addition, the soil phosphatase enzymatic activity decreased significantly (p<0.05) in both WWTS (dose related) and WTS treatments. For water organisms, a slight inhibition of the growth of Chlorella vulgaris was observed (WWTS treated soils), along with statistically significant dose-related inhibition responses on total glutathione cell content, and statistically significant dose-related induction responses on the glutathione S-transferase enzyme activity and the reactive oxygen species generation on the RTG-2 fish cell line. Copyright © 2014 Elsevier B.V. All rights reserved.
Su, Zhong; Zhang, Lisha; Ramakrishnan, V; Hagan, Michael; Anscher, Mitchell
2011-05-01
To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading accuracy in the presence of wireless electromagnetic transponders inside a phantom. A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with/without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with/without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit. Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%. The phantom study indicated that the Calypso System's localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems.
Jin, H; Zhang, H-N; Hou, X-L; Zhang, B; Wu, J; Zhang, H-B
2016-01-01
To investigate the clinical effect of double dose of valsartan combined with tacrolimus in the treatment of diabetic nephropathy (DN). HA total of 86 cases diagnosed with DN were selected from October 2013 to October 2014 in Zaozhuang Municipal Hospital, China. The study was approved by our hospital Ethics Committee and written consent was obtained from patients and their family members. Patients were randomly divided into three groups according to the sequence of admission, group A (conventional dose of valsartan group, n = 28 cases), group B (double dose of valsartan group, n = 29 cases) and group C (double dose of valsartan combined with tacrolimus group, n = 29). Clinical effects were compared by analyzing the renal function tests after 8 weeks. 24h urine protein, serum creatinine level of patients in group B and group C were significantly lower than that of group A. Those in group C was much lower. The glomerular filtration rates were significantly higher for group B and C than that of group A, and those in group C were much higher. The difference is statistically significant (p < 0.05). High-sensitivity C-reactive protein (hs CRP) and adiponectin levels of patients in group B and C of were significantly lower than that of group A and those in group C were much lower. The difference is statistically significant (p < 0.05). The high mobility group protein 1 (HMGB1) and renal tubular and interstitial damage index (TDI) of patients in B and C groups were significantly lower than those in the A group, and those in C group were significantly lower. The difference was statistically significant p < 0.05). The clinical effective rates of patients in group B and C were significantly higher than that in group A, and those of group C were much higher. The difference is statistically significant (p < 0.05). The recurrence rates of patients in group B and group C were significantly lower than those of group A and those in group C were much lower. The difference is statistically significant (p < 0.05). Patients in three groups showed no obvious drug complications. Double dose of valsartan combined with tacrolimus treatment of DN patients can improve clinical symptoms, reducing inflammation, inhibiting or even reversing the interstitial fibrosis, which will improve the curative effect and reduce the recurrence, as to provide a new theoretical basis for the clinical treatment of the disease.
Effect of Low-Dose MDCT and Iterative Reconstruction on Trabecular Bone Microstructure Assessment.
Kopp, Felix K; Holzapfel, Konstantin; Baum, Thomas; Nasirudin, Radin A; Mei, Kai; Garcia, Eduardo G; Burgkart, Rainer; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B
2016-01-01
We investigated the effects of low-dose multi detector computed tomography (MDCT) in combination with statistical iterative reconstruction algorithms on trabecular bone microstructure parameters. Twelve donated vertebrae were scanned with the routine radiation exposure used in our department (standard-dose) and a low-dose protocol. Reconstructions were performed with filtered backprojection (FBP) and maximum-likelihood based statistical iterative reconstruction (SIR). Trabecular bone microstructure parameters were assessed and statistically compared for each reconstruction. Moreover, fracture loads of the vertebrae were biomechanically determined and correlated to the assessed microstructure parameters. Trabecular bone microstructure parameters based on low-dose MDCT and SIR significantly correlated with vertebral bone strength. There was no significant difference between microstructure parameters calculated on low-dose SIR and standard-dose FBP images. However, the results revealed a strong dependency on the regularization strength applied during SIR. It was observed that stronger regularization might corrupt the microstructure analysis, because the trabecular structure is a very small detail that might get lost during the regularization process. As a consequence, the introduction of SIR for trabecular bone microstructure analysis requires a specific optimization of the regularization parameters. Moreover, in comparison to other approaches, superior noise-resolution trade-offs can be found with the proposed methods.
Rapalino, O; Kamalian, Shervin; Kamalian, Shahmir; Payabvash, S; Souza, L C S; Zhang, D; Mukta, J; Sahani, D V; Lev, M H; Pomerantz, S R
2012-04-01
To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed. Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P < .01). CNR values were also significantly higher at ASIR levels of ≥40% (P < .01). Blinded qualitative review demonstrated significant improvements in perceived image noise, artifacts, and GM-WM differentiation at ASIR levels ≥60% (P < .01). These results demonstrate that the use of ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.
Howlader, Md Amran; Alam, Mahmudul; Ahmed, Kh Tanvir; Khatun, Farjana; Apu, Apurba Sarker
2011-10-01
The ethanol leaf extract of Cymbidium aloifolium (L.) was evaluated for its analgesic and antiinflammatory activities. The extract, at the dose of 200 and 400 mg kg(-1) body weight, exerted the analgesic activity by observing the number of abdominal contractions and anti-inflammatory activity against Carrageenin induced paw edema in mice by measuring the paw volume. The ethanolic extract of Cymbidium aloifolium (L.) showed statistically significant (p < 0.05) reduction of percentage of writhing of 33.57 and 61.31% at 200 and 400 mg kg(-1) oral dose, respectively, when compared to negative control. The Ethanolic plant extract also showed significant (p < 0.05) dose dependent reduction of mean increase of formation of paw edema. The results of the experiment and its statistical analysis showed that the ethanolic plant extract had shown significant (p < 0.05) dose dependent analgesic and anti-inflammatory activities when compared to the control.
Correlation between the single, high dose of ingested baclofen and clinical symptoms.
Anand, Jacek Sein; Zając, Maciej; Waldman, Wojciech; Wojtyła, Andrzej; Biliński, Przemysław; Jaworska-Łuczak, Barbara
2017-12-23
Baclofen is a drug used mainly to treat muscle spasticity. Its overdose can lead to life-threatening clinical symptoms, including acute respiratory failure requiring mechanical ventilation. The aim of this study was to assess the prevalence of selected clinical symptoms associated with baclofen poisoning comparing to an ingested dose. 60 cases of oral baclofen poisoning were analyzed. Gender, age distribution, and correlation between the dose of ingested baclofen were studied, as well as and following clinical parameters: degree of altered consciousness, heart rate, blood pressure, presence of acute respiratory failure, duration of mechanical ventilation, and presence of psychotic symptoms. The study found statistically significant correlations between dosage of ingested baclofen and presence of acute respiratory failure, as well as duration of mechanical ventilation. No statistically significant correlations were found between the dose of ingested baclofen and presence of hypertension, bradycardia, acute psychotic symptoms, or level of consciousness disturbance. However, it was found that patients who suffered from hypertension, bradycardia, and altered mental status ingested a larger dose of baclofen. There is a statistically significant correlation between the dose of ingested baclofen and the presence of acute respiratory failure, and duration of mechanical ventilation. Patients who have taken a single dose of baclofen of 200 mg, or higher, should be managed in centres able to provide continuous monitoring of life functions. Those with a higher level of a single dose of baclofen ingestion (>500 mg), should be hospitalized in a Toxicology Unit or Intensive Care Unit able to provide airway support and mechanical ventilation.
Exposure of the surgeon's hands to radiation during hand surgery procedures.
Żyluk, Andrzej; Puchalski, Piotr; Szlosser, Zbigniew; Dec, Paweł; Chrąchol, Joanna
2014-01-01
The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals, wrist bones and distal radius. 218 operations (78%) were percutaneous procedures and 60 (22%) were performed by open method. Data on the time of exposure and dose of radiation were acquired from the display of the fluoroscope, where they were automatically generated. These data were assigned to the individual patient, type of fracture, method of surgery and the operating surgeon. Fixations of distal radial fractures required longer times of radiation exposure (mean 61 sec.) than fractures of the wrist/metacarpals and fingers (38 and 32 sec., respectively), which was associated with absorption of significantly higher equivalent doses. Fixations of distal radial fractures by open method were associated with statistically significantly higher equivalent doses (0.41 mSv) than percutaneous procedures (0.3 mSv). Fixations of wrist and metacarpal bone fractures by open method were associated with lower equivalent doses (0.34 mSv) than percutaneous procedures (0.37 mSv),but the difference was not significant. Fixations of finger fractures by open method were associated with lower equivalent doses (0.13 mSv) than percutaneous procedures (0.24 mSv), the difference being statistically non-significant. Statistically significant differences in exposure time and equivalent doses were noted between 4 surgeons participating in the study, but no definitive relationship was found between these parameters and surgeons' employment time. 1. Hand surgery procedures under fluoroscopic guidance are associated with mild exposure of the surgeons' hands to radiation. 2. The equivalent dose was related to the type of fracture, operative technique and - to some degree - to the time of employment of the surgeon.
Vardhanabhuti, Varut; James, Julia; Nensey, Rehaan; Hyde, Christopher; Roobottom, Carl
2015-05-01
To compare image quality on computed tomographic colonography (CTC) acquired at standard dose (STD) and low dose (LD) using filtered-back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) techniques. A total of 65 symptomatic patients were prospectively enrolled for the study and underwent STD and LD CTC with filtered-back projection, adaptive statistical iterative reconstruction, and MBIR to allow direct per-patient comparison. Objective image noise, subjective image analyses, and polyp detection were assessed. Objective image noise analysis demonstrates significant noise reduction using MBIR technique (P < .05) despite being acquired at lower doses. Subjective image analyses were superior for LD MBIR in all parameters except visibility of extracolonic lesions (two-dimensional) and visibility of colonic wall (three-dimensional) where there were no significant differences. There was no significant difference in polyp detection rates (P > .05). Doses: LD (dose-length product, 257.7), STD (dose-length product, 483.6). LD MBIR CTC objectively shows improved image noise using parameters in our study. Subjectively, image quality is maintained. Polyp detection shows no significant difference but because of small numbers needs further validation. Average dose reduction of 47% can be achieved. This study confirms feasibility of using MBIR in this context of CTC in symptomatic population. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Falgreen, Steffen; Laursen, Maria Bach; Bødker, Julie Støve; Kjeldsen, Malene Krag; Schmitz, Alexander; Nyegaard, Mette; Johnsen, Hans Erik; Dybkær, Karen; Bøgsted, Martin
2014-06-05
In vitro generated dose-response curves of human cancer cell lines are widely used to develop new therapeutics. The curves are summarised by simplified statistics that ignore the conventionally used dose-response curves' dependency on drug exposure time and growth kinetics. This may lead to suboptimal exploitation of data and biased conclusions on the potential of the drug in question. Therefore we set out to improve the dose-response assessments by eliminating the impact of time dependency. First, a mathematical model for drug induced cell growth inhibition was formulated and used to derive novel dose-response curves and improved summary statistics that are independent of time under the proposed model. Next, a statistical analysis workflow for estimating the improved statistics was suggested consisting of 1) nonlinear regression models for estimation of cell counts and doubling times, 2) isotonic regression for modelling the suggested dose-response curves, and 3) resampling based method for assessing variation of the novel summary statistics. We document that conventionally used summary statistics for dose-response experiments depend on time so that fast growing cell lines compared to slowly growing ones are considered overly sensitive. The adequacy of the mathematical model is tested for doxorubicin and found to fit real data to an acceptable degree. Dose-response data from the NCI60 drug screen were used to illustrate the time dependency and demonstrate an adjustment correcting for it. The applicability of the workflow was illustrated by simulation and application on a doxorubicin growth inhibition screen. The simulations show that under the proposed mathematical model the suggested statistical workflow results in unbiased estimates of the time independent summary statistics. Variance estimates of the novel summary statistics are used to conclude that the doxorubicin screen covers a significant diverse range of responses ensuring it is useful for biological interpretations. Time independent summary statistics may aid the understanding of drugs' action mechanism on tumour cells and potentially renew previous drug sensitivity evaluation studies.
2014-01-01
Background In vitro generated dose-response curves of human cancer cell lines are widely used to develop new therapeutics. The curves are summarised by simplified statistics that ignore the conventionally used dose-response curves’ dependency on drug exposure time and growth kinetics. This may lead to suboptimal exploitation of data and biased conclusions on the potential of the drug in question. Therefore we set out to improve the dose-response assessments by eliminating the impact of time dependency. Results First, a mathematical model for drug induced cell growth inhibition was formulated and used to derive novel dose-response curves and improved summary statistics that are independent of time under the proposed model. Next, a statistical analysis workflow for estimating the improved statistics was suggested consisting of 1) nonlinear regression models for estimation of cell counts and doubling times, 2) isotonic regression for modelling the suggested dose-response curves, and 3) resampling based method for assessing variation of the novel summary statistics. We document that conventionally used summary statistics for dose-response experiments depend on time so that fast growing cell lines compared to slowly growing ones are considered overly sensitive. The adequacy of the mathematical model is tested for doxorubicin and found to fit real data to an acceptable degree. Dose-response data from the NCI60 drug screen were used to illustrate the time dependency and demonstrate an adjustment correcting for it. The applicability of the workflow was illustrated by simulation and application on a doxorubicin growth inhibition screen. The simulations show that under the proposed mathematical model the suggested statistical workflow results in unbiased estimates of the time independent summary statistics. Variance estimates of the novel summary statistics are used to conclude that the doxorubicin screen covers a significant diverse range of responses ensuring it is useful for biological interpretations. Conclusion Time independent summary statistics may aid the understanding of drugs’ action mechanism on tumour cells and potentially renew previous drug sensitivity evaluation studies. PMID:24902483
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardin, M; To, D; Giaddui, T
2016-06-15
Purpose: To investigate the significance of using pinpoint ionization chambers (IC) and RadCalc (RC) in determining the quality of lung SBRT VMAT plans with low dose deviation pass percentage (DDPP) as reported by ScandiDos Delta4 (D4). To quantify the relationship between DDPP and point dose deviations determined by IC (ICDD), RadCalc (RCDD), and median dose deviation reported by D4 (D4DD). Methods: Point dose deviations and D4 DDPP were compiled for 45 SBRT VMAT plans. Eighteen patients were treated on Varian Truebeam linear accelerators (linacs); the remaining 27 were treated on Elekta Synergy linacs with Agility collimators. A one-way analysis ofmore » variance (ANOVA) was performed to determine if there were any statistically significant differences between D4DD, ICDD, and RCDD. Tukey’s test was used to determine which pair of means was statistically different from each other. Multiple regression analysis was performed to determine if D4DD, ICDD, or RCDD are statistically significant predictors of DDPP. Results: Median DDPP, D4DD, ICDD, and RCDD were 80.5% (47.6%–99.2%), −0.3% (−2.0%–1.6%), 0.2% (−7.5%–6.3%), and 2.9% (−4.0%–19.7%), respectively. The ANOVA showed a statistically significant difference between D4DD, ICDD, and RCDD for a 95% confidence interval (p < 0.001). Tukey’s test revealed a statistically significant difference between two pairs of groups, RCDD-D4DD and RCDD-ICDD (p < 0.001), but no difference between ICDD-D4DD (p = 0.485). Multiple regression analysis revealed that ICDD (p = 0.04) and D4DD (p = 0.03) are statistically significant predictors of DDPP with an adjusted r{sup 2} of 0.115. Conclusion: This study shows ICDD predicts trends in D4 DDPP; however this trend is highly variable as shown by our low r{sup 2}. This work suggests that ICDD can be used as a method to verify DDPP in delivery of lung SBRT VMAT plans. RCDD may not validate low DDPP discovered in D4 QA for small field SBRT treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhen, X; Chen, H; Liao, Y
Purpose: To study the feasibility of employing deformable registration methods for accurate rectum dose volume parameters calculation and their potentials in revealing rectum dose-toxicity between complication and non-complication cervical cancer patients with brachytherapy treatment. Method and Materials: Data from 60 patients treated with BT including planning images, treatment plans, and follow-up clinical exam were retrospectively collected. Among them, 12 patients complained about hematochezia were further examined with colonoscopy and scored as Grade 1–3 complication (CP). Meanwhile, another 12 non-complication (NCP) patients were selected as a reference group. To seek for potential gains in rectum toxicity prediction when fractional anatomical deformationsmore » are account for, the rectum dose volume parameters D0.1/1/2cc of the selected patients were retrospectively computed by three different approaches: the simple “worstcase scenario” (WS) addition method, an intensity-based deformable image registration (DIR) algorithm-Demons, and a more accurate, recent developed local topology preserved non-rigid point matching algorithm (TOP). Statistical significance of the differences between rectum doses of the CP group and the NCP group were tested by a two-tailed t-test and results were considered to be statistically significant if p < 0.05. Results: For the D0.1cc, no statistical differences are found between the CP and NCP group in all three methods. For the D1cc, dose difference is not detected by the WS method, however, statistical differences between the two groups are observed by both Demons and TOP, and more evident in TOP. For the D2cc, the CP and NCP cases are statistically significance of the difference for all three methods but more pronounced with TOP. Conclusion: In this study, we calculated the rectum D0.1/1/2cc by simple WS addition and two DIR methods and seek for gains in rectum toxicity prediction. The results favor the claim that accurate dose deformation and summation tend to be more sensitive in unveiling the dose-toxicity relationship. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).« less
Su, Zhong; Zhang, Lisha; Ramakrishnan, V.; Hagan, Michael; Anscher, Mitchell
2011-01-01
Purpose: To evaluate both the Calypso Systems’ (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal–oxide–semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters’ reading accuracy in the presence of wireless electromagnetic transponders inside a phantom.Methods: A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with∕without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with∕without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit.Results: Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%.Conclusions: The phantom study indicated that the Calypso System’s localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems. PMID:21776780
Solid Cancer Incidence in the Techa River Incidence Cohort: 1956-2007.
Davis, F G; Yu, K L; Preston, D; Epifanova, S; Degteva, M; Akleyev, A V
2015-07-01
Previously reported studies of the Techa River Cohort have established associations between radiation dose and the occurrence of solid cancers and leukemia (non-CLL) that appear to be linear in dose response. These analyses include 17,435 cohort members alive and not known to have had cancer prior to January 1, 1956 who lived in areas near the river or Chelyabinsk City at some time between 1956 and the end of 2007, utilized individualized dose estimates computed using the Techa River Dosimetry System 2009 and included five more years of follow-up. The median and mean dose estimates based on these doses are consistently higher than those based on earlier Techa River Dosimetry System 2000 dose estimates. This article includes new site-specific cancer risk estimates and risk estimates adjusted for available information on smoking. There is a statistically significant (P = 0.02) linear trend in the smoking-adjusted all-solid cancer incidence risks with an excess relative risk (ERR) after exposure to 100 mGy of 0.077 with a 95% confidence interval of 0.013-0.15. Examination of site-specific risks revealed statistically significant radiation dose effects only for cancers of the esophagus and uterus with an ERR per 100 mGy estimates in excess of 0.10. Esophageal cancer risk estimates were modified by ethnicity and sex, but not smoking. While the solid cancer rates are attenuated when esophageal cancer is removed (ERR = 0.063 per 100 mGy), a dose-response relationship is present and it remains likely that radiation exposure has increased the risks for most solid cancers in the cohort despite the lack of power to detect statistically significant risks for specific sites.
Chaikh, Abdulhamid; Balosso, Jacques
2016-12-01
To apply the statistical bootstrap analysis and dosimetric criteria's to assess the change of prescribed dose (PD) for lung cancer to maintain the same clinical results when using new generations of dose calculation algorithms. Nine lung cancer cases were studied. For each patient, three treatment plans were generated using exactly the same beams arrangements. In plan 1, the dose was calculated using pencil beam convolution (PBC) algorithm turning on heterogeneity correction with modified batho (PBC-MB). In plan 2, the dose was calculated using anisotropic analytical algorithm (AAA) and the same PD, as plan 1. In plan 3, the dose was calculated using AAA with monitor units (MUs) obtained from PBC-MB, as input. The dosimetric criteria's include MUs, delivered dose at isocentre (Diso) and calculated dose to 95% of the target volume (D95). The bootstrap method was used to assess the significance of the dose differences and to accurately estimate the 95% confidence interval (95% CI). Wilcoxon and Spearman's rank tests were used to calculate P values and the correlation coefficient (ρ). Statistically significant for dose difference was found using point kernel model. A good correlation was observed between both algorithms types, with ρ>0.9. Using AAA instead of PBC-MB, an adjustment of the PD in the isocentre is suggested. For a given set of patients, we assessed the need to readjust the PD for lung cancer using dosimetric indices and bootstrap statistical method. Thus, if the goal is to keep on with the same clinical results, the PD for lung tumors has to be adjusted with AAA. According to our simulation we suggest to readjust the PD by 5% and an optimization for beam arrangements to better protect the organs at risks (OARs).
Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-01-01
Recently, volumetric‐modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity‐modulated fixed‐field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs‐at‐risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed‐field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient‐specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single‐arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2‐T3 N0‐N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281–601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four‐field (n=4) or five‐field (n=9) step‐and‐shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose‐volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two‐arc plans. The comparison of VMATI with fixed‐field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p=0.47), PTV mean (p=0.12), PTV D95 and PTV V9547.5Gy (95%) (p=0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p=0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p=0.04). VMATI achieved lower lung V20 (p=0.05), whereas lung V5 (p=0.35) and mean lung dose (p=0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p=5.8E−10) and MUs reduced by up to 16% (p=0.001). Integral dose was not statistically different between the two planning techniques (p=0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p=0.76), PTV D95 (p=0.95), mean PTV dose (p=0.78), conformation number (CN) (p=0.26), and MUs (p=0.1). However, the treatment delivery time for VMATII increased significantly by two‐fold (p=3.0E−11) compared to VMATI. VMAT‐based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single‐arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI. PACS number: 87.53.Kn, 87.55.‐x PMID:23652258
Figueiró-Filho, Ernesto Antonio; Aydos, Ricardo Dutra; Senefonte, Flávio Renato de Almeida; Ferreira, Cristiane Munaretto; Pereira, Erica Freire de Vasconcelos; Oliveira, Vanessa Marcon de; Menezes, Giovanna Pádoa de; Bósio, Marco Antonio Costa
2014-07-01
To evaluate the effects of exposure of enoxaparin and unfractionated heparin (UFH) in prophylactic and therapeutic doses on the fertility rates of pregnant healthy Wistar rats. Enoxaparin and UFH were administered in prophylactic doses 1 mg/Kg/day 72 UI/Kg/day, and in therapeutic doses at 2 mg/kg/day 400UI/Kg/day. The rats were divided into five groups. The number of live and dead foetuses was quantified. The uterine horns were dissected and the presence of early and late reabsorptions (abortions) was determined. A p<0.05 was considered statistically significant. We did not observe statistically significant differences between groups when comparing the average weight of the foetuses and placentas, rate of female VS males, rates of pre-implantation loss (RPL), rates of efficiency implantation (REI), rates of post-implantation loss (RPIL) and rates of foetal viability (RFV). There was no significant effect on fertility with the use of anticoagulant drugs in pregnant healthy Wistar rats.
Effects of dietary methylmercury on juvenile Sacramento blackfish bioenergetics.
Houck, Ann; Cech, Joseph J
2004-08-10
Although much is known about the biogeochemical cycling of mercury in the environment, relatively little is known about methylmercury (MeHg) bioaccumulation in fishes and how chronic sub-lethal exposures affect their functioning. Several species of fish in Clear Lake, California have high MeHg tissue levels, including Sacramento blackfish, Orthodon microlepidotus, a large native cyprinid that is fished commercially. We fed juvenile blackfish one of four diets containing MeHg (0.21 mg/kg control; 0.52 mg/kg low; 22.2 mg/kg medium; and 55.5 mg/kg high treatments) for 70 days. There were no statistical differences (P > 0.05) in food consumption among the treatment groups. By 35 days the high treatment group had a significantly depressed growth rate when compared to the control group (P < 0.05) and by 70 days both the medium and the high groups had significantly lower growth rates (P < 0.05). The high-dose group had a significantly (P < 0.05) lower specific growth rate (SGR) compared all other treatment groups at 35 days, although by 70 days these differences were not significant. The wet/dry muscle mass and muscle mass/total mass ratios, condition factor, and resting routine metabolic rates at both 35 and 70 days were statistically indistinguishable (P > 0.05) between treatment groups. All treatment groups assimilated the dietary MeHg into muscle tissue in a dose-dependent fashion. Percent assimilation was significantly lower (P < 0.05) in the high-dose group compared to the low-dose group at 35 days, (control 53%, low-dose 61%, medium-dose 50%, and high-dose 40%) but at 70 days assimilation was lower (35, 43, 42, and 32%, respectively) and statistically indistinguishable (P > 0.05) among the treatment groups. Dietary MeHg concentrations and bioaccumulation rates were correlated (r2 = 0.98 at 35 days, 0.99 at 70 days). These results may contribute to construction of ecosystem mercury models and more informed natural resources management at Clear Lake.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Algan, O; Giem, J; Young, J
Purpose: To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiotherapy utilizing a single isocenter (SI) versus multiple isocenter (MI) in patients with multiple intracranial metastases. Methods: Seven patients imaged with MRI including SPGR sequence and diagnosed with 2–3 brain metastases were included in this retrospective study. Two sets of stereotactic IMRT treatment plans, (MI vs SI), were generated. The hippocampus was contoured on SPGR sequences and doses received by the hippocampus and whole brain were calculated. The prescribed dose was 25Gy in 5 fractions. The two groups were compared using t-testmore » analysis. Results: There were 17 lesions in 7 patients. The median tumor, right hippocampus, left hippocampus and brain volumes were: 3.37cc, 2.56cc, 3.28cc, and 1417cc respectively. In comparing the two treatment plans, there was no difference in the PTV coverage except in the tail of the DVH curve. All tumors had V95 > 99.5%. The only statistically significant parameter was the V100 (72% vs 45%, p=0.002, favoring MI). All other evaluated parameters including the V95 and V98 did not reveal any statistically significant differences. None of the evaluated dosimetric parameters for the hippocampus (V100, V80, V60, V40, V20, V10, D100, D90, D70, D50, D30, D10) revealed any statistically significant differences (all p-values > 0.31) between MI and SI plans. The total brain dose was slightly higher in the SI plans, especially in the lower dose regions, although this difference was not statistically significant. Utilizing brain-sub-PTV volumes did not change these results. Conclusion: The use of SI treatment planning for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain compared to MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.« less
Effects of Solar Particle Event Proton Radiation on Parameters Related to Ferret Emesis
Sanzari, J. K.; Wan, X. S.; Krigsfeld, G. S.; King, G. L.; Miller, A.; Mick, R.; Gridley, D. S.; Wroe, A. J.; Rightnar, S.; Dolney, D.; Kennedy, A. R.
2013-01-01
The effectiveness of simulated solar particle event (SPE) proton radiation to induce retching and vomiting was evaluated in the ferret experimental animal model. The endpoints measured in the study included: (1) the fraction of animals that retched or vomited, (2) the number of retches or vomits observed, (3) the latency period before the first retch or vomit and (4) the duration between the first and last retching or vomiting events. The results demonstrated that γ ray and proton irradiation delivered at a high dose rate of 0.5 Gy/min induced dose-dependent changes in the endpoints related to retching and vomiting. The minimum radiation doses required to induce statistically significant changes in retching- and vomiting-related endpoints were 0.75 and 1.0 Gy, respectively, and the relative biological effectiveness (RBE) of proton radiation at the high dose rate did not significantly differ from 1. Similar but less consistent and smaller changes in the retching- and vomiting-related endpoints were observed for groups irradiated with γ rays and protons delivered at a low dose rate of 0.5 Gy/h. Since this low dose rate is similar to a radiation dose rate expected during a SPE, these results suggest that the risk of SPE radiation-induced vomiting is low and may reach statistical significance only when the radiation dose reaches 1 Gy or higher. PMID:23883319
Peppa, V; Pappas, E P; Karaiskos, P; Major, T; Polgár, C; Papagiannis, P
2016-10-01
To investigate the clinical significance of introducing model based dose calculation algorithms (MBDCAs) as an alternative to TG-43 in 192 Ir interstitial breast brachytherapy. A 57 patient cohort was used in a retrospective comparison between TG-43 based dosimetry data exported from a treatment planning system and Monte Carlo (MC) dosimetry performed using MCNP v. 6.1 with plan and anatomy information in DICOM-RT format. Comparison was performed for the target, ipsilateral lung, heart, skin, breast and ribs, using dose distributions, dose-volume histograms (DVH) and plan quality indices clinically used for plan evaluation, as well as radiobiological parameters. TG-43 overestimation of target DVH parameters is statistically significant but small (less than 2% for the target coverage indices and 4% for homogeneity indices, on average). Significant dose differences (>5%) were observed close to the skin and at relatively large distances from the implant leading to a TG-43 dose overestimation for the organs at risk. These differences correspond to low dose regions (<50% of the prescribed dose), being less than 2% of the prescribed dose. Detected dosimetric differences did not induce clinically significant differences in calculated tumor control probabilities (mean absolute difference <0.2%) and normal tissue complication probabilities. While TG-43 shows a statistically significant overestimation of most indices used for plan evaluation, differences are small and therefore not clinically significant. Improved MBDCA dosimetry could be important for re-irradiation, technique inter-comparison and/or the assessment of secondary cancer induction risk, where accurate dosimetry in the whole patient anatomy is of the essence. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J
2014-01-01
To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.
Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rai, Bhavana; Patel, Firuza D., E-mail: firuzapatel@gmail.com; Chakraborty, Santam
2013-04-01
Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the secondmore » application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.« less
Shah, Amisha; Rees, Mitchell; Kar, Erica; Bolton, Kimberly; Lee, Vincent; Panigrahy, Ashok
2018-06-01
For the past several years, increased levels of imaging radiation and cumulative radiation to children has been a significant concern. Although several measures have been taken to reduce radiation dose during computed tomography (CT) scan, the newer dose reduction software adaptive statistical iterative reconstruction (ASIR) has been an effective technique in reducing radiation dose. To our knowledge, no studies are published that assess the effect of ASIR on extremity CT scans in children. To compare radiation dose, image noise, and subjective image quality in pediatric lower extremity CT scans acquired with and without ASIR. The study group consisted of 53 patients imaged on a CT scanner equipped with ASIR software. The control group consisted of 37 patients whose CT images were acquired without ASIR. Image noise, Computed Tomography Dose Index (CTDI) and dose length product (DLP) were measured. Two pediatric radiologists rated the studies in subjective categories: image sharpness, noise, diagnostic acceptability, and artifacts. The CTDI (p value = 0.0184) and DLP (p value <0.0002) were significantly decreased with the use of ASIR compared with non-ASIR studies. However, the subjective ratings for sharpness (p < 0.0001) and diagnostic acceptability of the ASIR images (p < 0.0128) were decreased compared with standard, non-ASIR CT studies. Adaptive statistical iterative reconstruction reduces radiation dose for lower extremity CTs in children, but at the expense of diagnostic imaging quality. Further studies are warranted to determine the specific utility of ASIR for pediatric musculoskeletal CT imaging.
On use of the multistage dose-response model for assessing laboratory animal carcinogenicity
Nitcheva, Daniella; Piegorsch, Walter W.; West, R. Webster
2007-01-01
We explore how well a statistical multistage model describes dose-response patterns in laboratory animal carcinogenicity experiments from a large database of quantal response data. The data are collected from the U.S. EPA’s publicly available IRIS data warehouse and examined statistically to determine how often higher-order values in the multistage predictor yield significant improvements in explanatory power over lower-order values. Our results suggest that the addition of a second-order parameter to the model only improves the fit about 20% of the time, while adding even higher-order terms apparently does not contribute to the fit at all, at least with the study designs we captured in the IRIS database. Also included is an examination of statistical tests for assessing significance of higher-order terms in a multistage dose-response model. It is noted that bootstrap testing methodology appears to offer greater stability for performing the hypothesis tests than a more-common, but possibly unstable, “Wald” test. PMID:17490794
Perez, Alfonso; Cao, Charlie
2017-03-01
In this phase 2, multicenter, parallel-group, double-blind, dose-ranging study, hypertensive adults (n=449) were randomized to receive one of five doses of a capsule formulation of azilsartan medoxomil (AZL-M; 5, 10, 20, 40, 80 mg), olmesartan medoxomil (OLM) 20 mg, or placebo once daily. The primary endpoint was change in trough clinic diastolic blood pressure (DBP) at week 8. AZL-M provided rapid statistically and clinically significant reductions in DBP and systolic blood pressure (SBP) vs placebo at all doses except 5 mg. Placebo-subtracted changes were greatest with the 40 mg dose (DBP, -5.7 mm Hg; SBP, -12.3 mm Hg). Clinic changes with AZL-M (all doses) were statistically indistinguishable vs OLM, although there were greater reductions with AZL-M 40 mg using 24-hour ambulatory blood pressure. Adverse event frequency was similar in the AZL-M and placebo groups. Based on these and other findings, subsequent trials investigated the commercial AZL-M tablet in the dose range of 20 to 80 mg/d. ©2016 Wiley Periodicals, Inc.
Taylor, Bryan F; Ramirez, Harvey E; Battles, August H; Andrutis, Karl A; Neubert, John K
2016-01-01
Effective pain management for rats and mice is crucial due to the continuing increase in the use of these species in biomedical research. Here we used a recently validated operant orofacial pain assay to determine dose–response curves for buprenorphine and tramadol when mixed in nut paste and administered to male and female rats. Statistically significant analgesic doses of tramadol in nut paste included doses of 20, 30, and 40 mg/kg for female rats but only 40 mg/kg for male rats. For male rats receiving buprenorphine mixed in nut paste, a significant analgesic response was observed at 0.5 and 0.6 mg/kg. None of the doses tested produced a significant analgesic response in female rats. Our results indicate that at the doses tested, tramadol and buprenorphine produced an analgesic response in male rats. In female rats, tramadol shows a higher analgesic effect than buprenorphine. The analgesic effects observed 60 min after administration of the statistically significant oral doses of both drugs were similar to the analgesic effects of 0.03 mg/kg subcutaneous buprenorphine 30 min after administration. The method of voluntary ingestion could be effective, is easy to use, and would minimize stress to the rats during the immediate postoperative period. PMID:26817983
Reducing Xerostomia After Chemo-IMRT for Head and Neck Cancer: Beyond Sparing the Parotid Glands
Little, Michael; Schipper, Matthew; Feng, Felix Y.; Vineberg, Karen; Cornwall, Craig; Murdoch-Kinch, Carol-Anne; Eisbruch, Avraham
2011-01-01
Purpose To assess whether in addition to sparing parotid glands (PGs), xerostomia after chemo-IMRT of head and neck cancer is affected by reducing doses to other salivary glands. Methods Prospective study: 78 patients with stages III/IV oropharynx/nasopharynx cancers received chemo-IMRT aiming to spare the parts outside the targets of bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) (when contralateral level I was not a target). Pretherapy and periodically through 24 months, validated patient-reported xerostomia questionnaires (XQ) scores and observer-graded xerostomia were recorded, and stimulated and unstimulated saliva measured selectively from each of the PGs and SMGs. Mean OC doses served as surrogates of minor salivary glands dysfunction. Regression models assessed XQ and observer-graded xerostomia predictors. Results Statistically significant predictors of the XQ score in univariate analysis included OC, PG, and SMG mean doses, as well as baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. OC, PG and SMG mean doses were moderately inter-correlated (r=0.47–0.55). In multivariate analyses, after adjusting for PG and SMG doses, OC mean dose (p < 0.0001), time from RT (p < 0.0001), and stimulated PG saliva (p < 0.0025) were significant predictors for XQ scores, and OC mean dose and time for observer-graded xerostomia. While scatter plots showed no thresholds, OC mean doses <40 Gy and contralateral SMG mean <50 Gy were each associated with low patient-reported and observer-rated xerostomia at almost all post-therapy time points. Conclusion PG, SMG and OC mean doses were significant predictors of both patient-reported and observer-rated xerostomia after chemo-IMRT, with OC doses remaining significant after adjusting for PG and SMG doses. These results support efforts to spare all salivary glands by IMRT, beyond the PGs alone. PMID:22056067
Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K
2017-08-01
To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p < 0.01). Variation in point doses between fixed-mA and AEC protocols were statistically significant across all organs at all Table positions (p < 0.001). There was up to 5-6% decrease in point doses with upward off-centering and in downward off-centering. There were statistical significant differences in point doses from dosimeters and dose-tracking software (mean difference for internal organs, 5-36% for fixed-mA & 7-48% for AEC protocols; p < 0.001; mean difference for surface organs, >92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Efficacy and Safety of Doxepin 1 mg, 3 mg, and 6 mg in Adults with Primary Insomnia
Roth, Thomas; Rogowski, Roberta; Hull, Steven; Schwartz, Howard; Koshorek, Gail; Corser, Bruce; Seiden, David; Lankford, Alan
2007-01-01
Study Objectives: To evaluate the efficacy and safety of doxepin 1, 3, and 6 mg in insomnia patients. Design: Adults (18-64 y) with chronic primary insomnia (DSM-IV) were randomly assigned to one of four sequences of 1 mg, 3 mg, and 6 mg of doxepin, and placebo in a crossover study. Treatment periods consisted of 2 polysomnographic assessment nights with a 5-day or 12-day drug-free interval between periods. Efficacy was assessed using polysomnography (PSG) and patient-reported measures. Safety analyses included measures of residual sedation and adverse events. Measurements and Results: Sixty-seven patients were randomized. Wake time during sleep, the a priori defined primary endpoint, was statistically significantly improved at the doxepin 3 mg and 6 mg doses versus placebo. All three doses had statistically significant improvements versus placebo for PSG-defined wake after sleep onset, total sleep time, and overall sleep efficiency (SE). SE in the final third-of-the-night also demonstrated statistically significant improvement at all doses. The doxepin 6 mg dose significantly reduced subjective latency to sleep onset. All three doxepin doses had a safety profile comparable to placebo. There were no statistically significant differences in next-day residual sedation, and sleep architecture was generally clinically preserved. Conclusions: In adults with primary insomnia, doxepin 1 mg, 3 mg, and 6 mg was well-tolerated and produced improvement in objective and subjective sleep maintenance and duration endpoints that persisted into the final hour of the night. The side-effect profile was comparable to placebo, with no reported anticholinergic effects, no memory impairment, and no significant hangover/next-day residual effects. These data demonstrate that doxepin 1 mg, 3 mg, and 6 mg is efficacious in improving the sleep of patients with chronic primary insomnia. Citation: Roth T; Rogowski R; Hull S; Schwartz H; Koshorek G; Corser B; Seiden D. Efficacy and safety of doxepin 1 mg, 3 mg, and 6 mg in adults with primary insomnia. SLEEP 2007;30(11):1555-1561. PMID:18041488
El-Sayed, Mohamed Lotfy Mohamed; Ahmed, Mostafa Abdo; Mansour, Marwa Abdel Azim; Mansour, Shymma Abdel Azim
2017-10-01
This study aimed to evaluate the efficacy of unilateral laparoscopic ovarian drilling versus bilateral laparoscopic ovarian drilling with thermal dose adjusted according to ovarian volume in clomiphene citrate (CC)-resistant PCOS patients in terms of endocrine changes, menstrual cycle resumption, ovulation and pregnancy rates. This study was conducted in the Department of Obstetrics and Gynecology, Zagazig university hospitals. One hundred CC-resistant PCOS patients were divided into two groups. Group (I) (50 patients) underwent unilateral laparoscopic ovarian drilling with thermal dose adjusted according to ovarian volume (60 J/cm 3 of ovarian tissue), and group (II) (50 patients) underwent bilateral laparoscopic ovarian drilling using the same previously mentioned thermal dose. Endocrinal changes and menstrual cycle resumption were assessed within 8 weeks postoperatively, but the ovulation and pregnancy rates were estimated after 6-month follow-up period. There was no statistically significant difference between the two groups as regards demographic data ( p > 0.05). As regards menstruation cycle resumption (62.5 vs. 81%) ( p = 0.047), total ovulation rate (54.2 vs. 78.7%) ( p = 0.011) and cumulative pregnancy rate (33.3 vs. 55.3%) ( p = 0.031), there was statistically significant difference between both groups. After drilling, there were highly statistically significant decrease in the mean serum levels of luteinizing hormone (LH) and significant decrease in the mean serum levels of testosterone in both groups. Mean serum level of follicle stimulating hormone (FSH) did not change significantly in both groups after drilling. Bilateral laparoscopic ovarian drilling with thermal dose adjusted according to ovarian volume is more effective than the right-sided unilateral technique with thermal dose adjusted according to ovarian volume in terms of menstrual cycle resumption, ovulation and cumulative pregnancy rates in CC-resistant PCOS patients.
Impact of Gender on Pharmocokinetics of Intranasal Scopolamine
NASA Technical Reports Server (NTRS)
Putcha, L.; Lei, Wu.; S-L Chow, Diana
2013-01-01
Introduction: An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS), which is commonly experienced by astronauts during space missions. The bioavailability and pharmacokinetics (PK) were evaluated under IND guidelines. Since information is lacking on the effect of gender on the PK of Scopolamine, we examined gender differences in PK parameters of INSCOP at three dose levels of 0.1, 0.2 and 0.4 mg. Methods: Plasma scopolamine concentrations as a function of time data were collected from twelve normal healthy human subjects (6 male/6 female) who participated in a fully randomized double blind crossover study. The PK parameters were derived using WinNonlin. Covariate analysis of PK profiles was performed using NONMEN and statistically compared using a likelihood ratio test on the difference of objective function value (OFV). Statistical significance for covariate analysis was set at P<0.05(?OFV=3.84). Results: No significant difference in PK parameters between male and female subjects was observed with 0.1 and 0.2 mg doses. However, CL and Vd were significantly different between male and female subjects at the 0.4 mg dose. Results from population covariate modeling analysis indicate that a onecompartment PK model with first-order elimination rate offers best fit for describing INSCOP concentration-time profiles. The inclusion of sex as a covariate enhanced the model fitting (?OFV=-4.1) owing to the genderdependent CL and Vd differences after the 0.4 mg dose. Conclusion: Statistical modeling of scopolamine concentration-time data suggests gender-dependent pharmacokinetics of scopolamine at the high dose level of 0.4 mg. Clearance of the parent compound was significantly faster and the volume of distribution was significantly higher in males than in females, As a result, including gender as a covariate to the pharmacokinetic model of scopolamine offers the best fit for PK modeling of the drug at dose of 0.4 mg or higher.
Shuman, William P; Chan, Keith T; Busey, Janet M; Mitsumori, Lee M; Choi, Eunice; Koprowicz, Kent M; Kanal, Kalpana M
2014-12-01
To investigate whether reduced radiation dose liver computed tomography (CT) images reconstructed with model-based iterative reconstruction ( MBIR model-based iterative reconstruction ) might compromise depiction of clinically relevant findings or might have decreased image quality when compared with clinical standard radiation dose CT images reconstructed with adaptive statistical iterative reconstruction ( ASIR adaptive statistical iterative reconstruction ). With institutional review board approval, informed consent, and HIPAA compliance, 50 patients (39 men, 11 women) were prospectively included who underwent liver CT. After a portal venous pass with ASIR adaptive statistical iterative reconstruction images, a 60% reduced radiation dose pass was added with MBIR model-based iterative reconstruction images. One reviewer scored ASIR adaptive statistical iterative reconstruction image quality and marked findings. Two additional independent reviewers noted whether marked findings were present on MBIR model-based iterative reconstruction images and assigned scores for relative conspicuity, spatial resolution, image noise, and image quality. Liver and aorta Hounsfield units and image noise were measured. Volume CT dose index and size-specific dose estimate ( SSDE size-specific dose estimate ) were recorded. Qualitative reviewer scores were summarized. Formal statistical inference for signal-to-noise ratio ( SNR signal-to-noise ratio ), contrast-to-noise ratio ( CNR contrast-to-noise ratio ), volume CT dose index, and SSDE size-specific dose estimate was made (paired t tests), with Bonferroni adjustment. Two independent reviewers identified all 136 ASIR adaptive statistical iterative reconstruction image findings (n = 272) on MBIR model-based iterative reconstruction images, scoring them as equal or better for conspicuity, spatial resolution, and image noise in 94.1% (256 of 272), 96.7% (263 of 272), and 99.3% (270 of 272), respectively. In 50 image sets, two reviewers (n = 100) scored overall image quality as sufficient or good with MBIR model-based iterative reconstruction in 99% (99 of 100). Liver SNR signal-to-noise ratio was significantly greater for MBIR model-based iterative reconstruction (10.8 ± 2.5 [standard deviation] vs 7.7 ± 1.4, P < .001); there was no difference for CNR contrast-to-noise ratio (2.5 ± 1.4 vs 2.4 ± 1.4, P = .45). For ASIR adaptive statistical iterative reconstruction and MBIR model-based iterative reconstruction , respectively, volume CT dose index was 15.2 mGy ± 7.6 versus 6.2 mGy ± 3.6; SSDE size-specific dose estimate was 16.4 mGy ± 6.6 versus 6.7 mGy ± 3.1 (P < .001). Liver CT images reconstructed with MBIR model-based iterative reconstruction may allow up to 59% radiation dose reduction compared with the dose with ASIR adaptive statistical iterative reconstruction , without compromising depiction of findings or image quality. © RSNA, 2014.
Kashcheev, V V; Chekin, S Yu; Maksioutov, M A; Tumanov, K A; Menyaylo, A N; Kochergina, E V; Kashcheeva, P V; Gorsky, A I; Shchukina, N V; Karpenko, S V; Ivanov, V K
2016-08-01
The paper presents an analysis of the incidence of cerebrovascular diseases (CeVD) in the cohort of Russian workers involved in recovery tasks after the Chernobyl accident. The studied cohort consists of 53,772 recovery operation workers (liquidators) who arrived in the zone of the Chernobyl accident within the first year after this accident (26 April 1986-26 April 1987). The mean external whole body dose in the cohort was 0.161 Gy, while individual doses varied from 0.0001 Gy to 1.42 Gy. During the follow-up period 1986-2012, a total of 23,264 cases of CeVD were diagnosed as a result of annual health examinations. A Poisson regression model was applied for estimation of radiation risks and for an assessment of other risk factors of CeVD. The following factors were considered as risk factors for CeVD: the dose, duration of the liquidators' work in the Chernobyl zone, and the concomitant diseases (hypertension, ischemic heart disease, atherosclerosis, and diabetes). The baseline incidence of CeVD is statistically significantly (p < 0.001) associated with all studied concomitant diseases. The incidence of CeVD has revealed a statistically significant dose response with the lack of a latent period and with the average ERR/Gy = 0.45, 95% CI: (0.28, 0.62), p < 0.001. Radiation risks of CeVD statistically significantly (p = 0.03) varied with the duration of liquidators' stay in the Chernobyl zone; for those who stayed in the Chernobyl zone less than 6 wk, ERR/Gy = 0.64, 95% CI = (0.38; 0.93), p < 0.001. Among studied concomitant diseases, diabetes mellitus statistically significantly (p = 0.002) increases the radiation risk of CeVD: for liquidators with diagnosed diabetes, ERR/Gy = 1.29.
Chaikh, Abdulhamid; Balosso, Jacques
2016-12-01
This study proposes a statistical process to compare different treatment plans issued from different irradiation techniques or different treatment phases. This approach aims to provide arguments for discussion about the impact on clinical results of any condition able to significantly alter dosimetric or ballistic related data. The principles of the statistical investigation are presented in the framework of a clinical example based on 40 fields of radiotherapy for lung cancers. Two treatment plans were generated for each patient making a change of dose distribution due to variation of lung density correction. The data from 2D gamma index (γ) including the pixels having γ≤1 were used to determine the capability index (Cp) and the acceptability index (Cpk) of the process. To measure the strength of the relationship between the γ passing rates and the Cp and Cpk indices, the Spearman's rank non-parametric test was used to calculate P values. The comparison between reference and tested plans showed that 95% of pixels have γ≤1 with criteria (6%, 6 mm). The values of the Cp and Cpk indices were lower than one showing a significant dose difference. The data showed a strong correlation between γ passing rates and the indices with P>0.8. The statistical analysis using Cp and Cpk, show the significance of dose differences resulting from two plans in radiotherapy. These indices can be used for adaptive radiotherapy to measure the difference between initial plan and daily delivered plan. The significant changes of dose distribution could raise the question about the continuity to treat the patient with the initial plan or the need for adjustments.
Mortazavi, SMJ; Mosleh-Shirazi, MA; Tavassoli, AR; Taheri, M; Mehdizadeh, AR; Namazi, SAS; Jamali, A; Ghalandari, R; Bonyadi, S; Haghani, M; Shafie, M
2013-01-01
The aim of this study was to investigate the effect of pre-irradiation with microwaves on the induction of radioadaptive response. In the 1st phase of the study, 110 male mice were divided into 8 groups. The animals in these groups were exposed/sham-exposed to microwave, low dose rate gamma or both for 5 days. On day six, the animals were exposed to a lethal dose (LD). In the 2nd phase, 30 male rats were divided into 2 groups of 15 animals. The 1st group received microwave exposure. The 2nd group (controls) received the same LD but there was no treatment before the LD. On day 5, all animals were whole-body irradiated with the LD. Statistically significant differences between the survival rate of the mice only exposed to lethal dose of gamma radiation before irradiation with a lethal dose of gamma radiation with those of the animals pre-exposed to either microwave (p=0.02), low dose rate gamma (p=0.001) or both of these physical adapting doses (p=0.003) were observed. Likewise, a statistically significant difference between survival rates of the rats in control and test groups was observed. Altogether, these experiments showed that exposure to microwave radiation may induce a significant survival adaptive response. PMID:23930107
Evaluation of Supercritical Extracts of Algae as Biostimulants of Plant Growth in Field Trials.
Michalak, Izabela; Chojnacka, Katarzyna; Dmytryk, Agnieszka; Wilk, Radosław; Gramza, Mateusz; Rój, Edward
2016-01-01
The aim of the field trials was to determine the influence of supercritical algal extracts on the growth and development of winter wheat (variety Akteur ). As a raw material for the supercritical fluid extraction, the biomass of microalga Spirulina plantensis , brown seaweed - Ascophyllum nodosum and Baltic green macroalgae was used. Forthial and Asahi SL constituted the reference products. It was found that the tested biostimulants did not influence statistically significantly the plant height, length of ear, and shank length. The ear number per m 2 was the highest in the group where the Baltic macroalgae extract was applied in the dose 1.0 L/ha (statistically significant differences). Number of grains in ear (statistically significant differences) and shank length was the highest in the group treated with Spirulina at the dose 1.5 L/ha. In the group with Ascophyllum at the dose 1.0 L/ha, the highest length of ear was observed. The yield was comparable in all the experimental groups (lack of statistically significant differences). Among the tested supercritical extracts, the best results were obtained for Spirulina (1.5 L/ha). The mass of 1000 grains was the highest for extract from Baltic macroalgae and was 3.5% higher than for Asahi, 4.0% higher than for Forthial and 18.5% higher than for the control group (statistically significant differences). Future work is needed to fully characterize the chemical composition of the applied algal extracts. A special attention should be paid to the extracts obtained from Baltic algae because they are inexpensive source of naturally occurring bioactive compounds, which can be used in sustainable agriculture and horticulture.
Evaluation of Supercritical Extracts of Algae as Biostimulants of Plant Growth in Field Trials
Michalak, Izabela; Chojnacka, Katarzyna; Dmytryk, Agnieszka; Wilk, Radosław; Gramza, Mateusz; Rój, Edward
2016-01-01
The aim of the field trials was to determine the influence of supercritical algal extracts on the growth and development of winter wheat (variety Akteur). As a raw material for the supercritical fluid extraction, the biomass of microalga Spirulina plantensis, brown seaweed – Ascophyllum nodosum and Baltic green macroalgae was used. Forthial and Asahi SL constituted the reference products. It was found that the tested biostimulants did not influence statistically significantly the plant height, length of ear, and shank length. The ear number per m2 was the highest in the group where the Baltic macroalgae extract was applied in the dose 1.0 L/ha (statistically significant differences). Number of grains in ear (statistically significant differences) and shank length was the highest in the group treated with Spirulina at the dose 1.5 L/ha. In the group with Ascophyllum at the dose 1.0 L/ha, the highest length of ear was observed. The yield was comparable in all the experimental groups (lack of statistically significant differences). Among the tested supercritical extracts, the best results were obtained for Spirulina (1.5 L/ha). The mass of 1000 grains was the highest for extract from Baltic macroalgae and was 3.5% higher than for Asahi, 4.0% higher than for Forthial and 18.5% higher than for the control group (statistically significant differences). Future work is needed to fully characterize the chemical composition of the applied algal extracts. A special attention should be paid to the extracts obtained from Baltic algae because they are inexpensive source of naturally occurring bioactive compounds, which can be used in sustainable agriculture and horticulture. PMID:27826310
Effects of the food additive, citric acid, on kidney cells of mice.
Chen, Xg; Lv, Qx; Liu, Ym; Deng, W
2015-01-01
Citric acid is a food additive that is widely used in the food and drink industry. We investigated the effects of citric acid injection on mouse kidney. Forty healthy mice were divided into four groups of 10 including one control group and three citric acid-treated groups. Low dose, middle dose and high dose groups were given doses of 120, 240 and 480 mg/kg of citric acid, respectively. On day 7, kidney tissues were collected for histological, biochemical and molecular biological examination. We observed shrinkage of glomeruli, widened urinary spaces and capillary congestion, narrowing of the tubule lumen, edema and cytoplasmic vacuolated tubule cells, and appearance of pyknotic nuclei. The relation between histopathological changes and citric acid was dose dependent. Compared to the control, T-SOD and GSH-Px activities in the treated groups decreased with increasing doses of citric acid, NOS activity tended to increase, and H2O2 and MDA contents gradually decreased, but the differences between any treated group and the control were not statistically significant. The apoptosis assay showed a dose-dependent increase of caspase-3 activity after administering citrate that was statistically significant. DNA ladder formation occurred after treatment with any dose of citric acid. We concluded that administration of citric acid may cause renal toxicity in mice.
Developmental toxicity study of D-tagatose in rats.
Kruger, C L; Whittaker, M H; Frankos, V H; Schroeder, R E
1999-04-01
D-tagatose is a low-calorie sweetener that tastes like sucrose. The developmental toxicity of D-tagatose was investigated in Crl:CD(SD)BR rats administered D-tagatose at three dose levels (4000, 12,000, and 20,000 mg/kg body wt/day) via gastric intubation on days 6-15 of gestation. No compound-related toxicity was seen among any of the maternal groups. No treatment-related clinical effects were seen in the maternal animals at the 4000 mg/kg/day dose level. At the mid- and high-dose levels, most maternal animals had unformed or watery stools; this effect was most prominent early in the treatment period (Gestation Days 6-8). This effect was attributed to the osmotic effect of the large amount of D-tagatose given to the animals at these doses. Since D-tagatose is not digested or absorbed to a large extent, most of the sugar passes into the colon where it absorbs water and is fermented by colonic bacteria. Mean weight gain for the low- and mid-dose animals was comparable to the control; however, the high-dose group experienced a mean weight loss over the Gestation Day 6-9 interval. Over the entire treatment interval, however, mean weight gain for the high-dose animals was comparable to control. The decreased weight gain in the high-dose animals during the Gestation Day 6-9 interval was considered to be a direct result of laxation. In addition to the effect of laxation on body weight, reduced food consumption also contributed to the decreased weight gain. In the low-dose animals, no effect on food consumption was seen; however, both mid- and high-dose animals had food consumption values that were statistically significantly lower than the control. Food consumption was lowest during the Gestation Day 6-9 interval, the period when laxation was most prominent. Food consumption rebounded and was statistically significantly higher than the control for the mid- and high-dose animals during the posttreatment interval. Maternal liver weight for the low-dose animals was comparable to the control. However, a statistically significant increase in mean maternal liver weight was noted for the mid-and high-dose animals. Based on a lack of any corresponding histopathology, the increased liver weights were not considered toxicologically significant. There were no adverse effects on reproductive performance noted in any treatment group. No adverse treatment-related fetal effects on fetal weight, sex distribution, liver weight, or external, skeletal, or visceral malformations were noted at any dose level. Copyright 1999 Academic Press.
NASA Astrophysics Data System (ADS)
Sun, Taohua; Zhang, Xinhui; Miao, Ying; Zhou, Yang; Shi, Jie; Yan, Meixing; Chen, Anjin
2018-06-01
The antiviral activity in vitro and in vivo and the effect of the immune system of two fucoidan fractions with low molecular weight and different sulfate content from Laminaria japonica (LMW fucoidans) were investigated in order to examine the possible mechanism. In vitro, I-type influenza virus, adenovirus and Parainfluenza virus I were used to infect Hep-2, Hela and MDCK cells, respectively. And 50% tissue culture infective dose was calculated to detect the antiviral activity of two LMW fucoidans. The results indicated that compared with the control group, 2 kinds of LMW fucoidans had remarkable antiviral activity in vitro in middle and high doses, while at low doses, the antiviral activity of 2 kinds of LMW fucoidans was not statistically different from that in the blank control group. And there was no statistically difference between two LMW fucoidans in antiviral activity. In vivo, LMW fucoidans could prolong the survival time of virus-infected mice, and could improve the lung index of virus-infected mice significantly, which have statistical differences with the control group significantly ( p < 0.01). However, the survival time of the two LMW fucoidans was not statistically significant ( p > 0.05). In this study, it was shown that both of two LMW fucoidans (LF1, LF2) could increase the thymus index, spleen index, phagocytic index, phagocytosis coefficient and half hemolysin value in middle and high doses, which suggested that LMW fucoidans could play an antiviral role by improving the quality of immune organs, improving immune cell phagocytosis and humoral immunity.
Shamim, Rafat; Srivastava, Shashi; Rastogi, Amit; Kishore, Kamal; Srivastava, Aneesh
2017-01-01
Clonidine, opioids, β-blockers, and dexmedetomidine have been tried to attenuate stress responses during laparoscopic surgery. We evaluated the efficacy of dexmedetomidine in two different doses in attenuating stress responses on patients undergoing laparoscopic pyeloplasty. Ninety patients were assigned to one of the three groups: Group A, Group B, and Group C. Group B received dexmedetomidine 1 mcg/kg as loading dose, followed by 0.7 mcg/kg/h for maintenance; Group C received dexmedetomidine 0.7 mcg/kg as a loading dose, followed by 0.5 mcg/kg/h for maintenance. Group A received normal saline. Stress responses were assessed by the variations in heart rate (HR), mean arterial pressure (MAP), blood glucose levels, and serum cortisol levels. One-way analysis of variance test was applied. Multiple comparisons between groups were done with post hoc Bonferroni test. The HR and MAP were found to be higher in Group A. The difference was statistically significant ( P < 0.05) during intubation, carbon dioxide insufflation, and extubation when compared with Groups B and C. Blood glucose levels at postintubation and at extubation were higher in Group A and statistically significant ( P < 0.05) when compared with Groups B and C. Serum cortisol levels at postintubation, during midsurgery, and 2 h after extubation were higher in Group A and statistically significant ( P < 0.05) when compared with Groups B and C. However, HR, MAP, blood glucose levels, and serum cortisol levels were similar in dexmedetomidine groups. Dexmedetomidine decreases stress response and provides good condition for maintenance of anesthesia. Dexmedetomidine when used in lower dose in Group C decreases stress response comparable to higher dose in Group B.
Ramírez-Herráiz, Esther; Escudero-Vilaplana, Vicente; Alañón-Plaza, Estefanía; Trovato-López, Nicolás; Herranz-Alonso, Ana; Morell-Baladrón, Alberto; Sanjurjo-Sáez, María
2013-01-01
This retrospective, multicentre, observational study aimed to assess the mean annual doses and associated costs of three anti-tumour necrosis factor agents in daily clinical practice in rheumatoid arthritis patients, correlating these costs with disease activity. Adult rheumatoid arthritis patients were treated and followed at the Rheumatology departments of two Spanish hospitals for at least 6 months, with adalimumab, etanercept or infliximab over a 4-year period. ANOVA and multivariate statistical analyses of dosing patterns, disease activity and annualised costs were carried out. A total of 198 patients, comprising 215 cases, met the inclusion criteria (73 on adalimumab, 81 etanercept and 61 infliximab). Compared to recommended doses, mean doses of adalimumab and etanercept decreased by 7% and 19%, respectively, while the mean dose of infliximab increased by 36%. There were no statistical differences between treatments in terms of clinical effectiveness. The hazard of dose escalation was significantly higher for either adalimumab (4.4-fold) or infliximab (11.8-fold) compared to etanercept (p<0.05). Clinical control was achieved and maintained in more than half of the patients treated with reduced doses of etanercept. Associated mean patient-year costs were significantly higher in adalimumab patients (€11.962.58) (etanercept €9.594.73; infliximab €10.094.53; [p<0.05]). In rheumatoid arthritis patients, it is possible to reduce doses and associated costs of biological therapies while controlling disease activity. Mean doses used in our clinical practice were significantly lower with etanercept than with the anti-TNF monoclonal antibodies, adalimumab and infliximab. Dose differences impact directly on associated patient-year costs, and thus on treatment efficiency.
A comparison of sequential and spiral scanning techniques in brain CT.
Pace, Ivana; Zarb, Francis
2015-01-01
To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).
Sun, Hong; Kennedy, William P; Wilbraham, Darren; Lewis, Nicole; Calder, Nicole; Li, Xiaodong; Ma, Junshui; Yee, Ka Lai; Ermlich, Susan; Mangin, Eric; Lines, Christopher; Rosen, Laura; Chodakewitz, Jeffrey; Murphy, Gail M
2013-02-01
Suvorexant (MK-4305) is an orexin receptor antagonist being developed for the treatment of insomnia. This report describes the effects of nighttime administration of suvorexant on polysomnography (PSG) sleep parameters in healthy young men. Randomized, double-blind, placebo-controlled, 4-period crossover PSG study, followed by an additional 5(th) period to assess pharmacokinetics. Sleep laboratory. Healthy young men between 18 and 45 years of age (22 enrolled, 19 completed). Periods 1-4: suvorexant (10 mg, 50 mg, or 100 mg) or placebo 1 h before nighttime PSG recording. Period 5: suvorexant 10 mg, 50 mg, or 100 mg. In Periods 1-4, overnight sleep parameters were recorded by PSG and next-morning residual effects were assessed by psychomotor performance tests and subjective assessments. Statistically significant sleep-promoting effects were observed with all doses of suvorexant compared to placebo. Suvorexant 50 mg and 100 mg significantly decreased latency to persistent sleep and wake after sleep onset time, and increased sleep efficiency. Suvorexant 10 mg significantly decreased wake after sleep onset time. There were no statistically significant effects of suvorexant on EEG frequency bands including delta (slow wave) activity based on power spectral analysis. Suvorexant was well tolerated. There was no evidence of next-day residual effects for suvorexant 10 mg. Suvorexant 50 mg statistically significantly reduced subjective alertness, and suvorexant 100 mg significantly increased reaction time and reduced subjective alertness. There were no statistically significant effects of any suvorexant dose on digit symbol substitution test performance. In Period 5, plasma samples of suvorexant were collected for pharmacokinetic evaluation. The median T(max) was 3 hours and apparent terminal t(½) was 9-13 hours. In healthy young men without sleep disorders, suvorexant promoted sleep with some evidence of residual effects at the highest doses.
Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F
2016-05-01
To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
King, Christopher R
2016-11-01
To date neither the optimal radiotherapy dose nor the existence of a dose-response has been established for salvage RT (SRT). A systematic review from 1996 to 2015 and meta-analysis was performed to identify the pathologic, clinical and treatment factors associated with relapse-free survival (RFS) after SRT (uniformly defined as a PSA>0.2ng/mL or rising above post-SRT nadir). A sigmoidal dose-response curve was objectively fitted and a non-parametric statistical test used to determine significance. 71 studies (10,034 patients) satisfied the meta-analysis criteria. SRT dose (p=0.0001), PSA prior to SRT (p=0.0009), ECE+ (p=0.039) and SV+ (p=0.046) had significant associations with RFS. Statistical analyses confirmed the independence of SRT dose-response. Omission of series with ADT did not alter results. Dose-response is well fit by a sigmoidal curve (p=0.0001) with a TCD 50 of 65.8Gy, with a dose of 70Gy achieving 58.4% RFS vs. 38.5% for 60Gy. A 2.0% [95% CI 1.1-3.2] improvement in RFS is achieved for each Gy. The SRT dose-response remarkably parallels that for definitive RT of localized disease. This study provides level 2a evidence for dose-escalated SRT>70Gy. The presence of an SRT dose-response for microscopic disease supports the hypothesis that prostate cancer is inherently radio-resistant. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Buettner, Florian; Gulliford, Sarah L.; Webb, Steve; Sydes, Matthew R.; Dearnaley, David P.; Partridge, Mike
2009-11-01
Many studies have been performed to assess correlations between measures derived from dose-volume histograms and late rectal toxicities for radiotherapy of prostate cancer. The purpose of this study was to quantify correlations between measures describing the shape and location of the dose distribution and different outcomes. The dose to the rectal wall was projected on a two-dimensional map. In order to characterize the dose distribution, its centre of mass, longitudinal and lateral extent, and eccentricity were calculated at different dose levels. Furthermore, the dose-surface histogram (DSH) was determined. Correlations between these measures and seven clinically relevant rectal-toxicity endpoints were quantified by maximally selected standardized Wilcoxon rank statistics. The analysis was performed using data from the RT01 prostate radiotherapy trial. For some endpoints, the shape of the dose distribution is more strongly correlated with the outcome than simple DSHs. Rectal bleeding was most strongly correlated with the lateral extent of the dose distribution. For loose stools, the strongest correlations were found for longitudinal extent; proctitis was most strongly correlated with DSH. For the other endpoints no statistically significant correlations could be found. The strengths of the correlations between the shape of the dose distribution and outcome differed considerably between the different endpoints. Due to these significant correlations, it is desirable to use shape-based tools in order to assess the quality of a dose distribution.
A knowledge-based approach to automated planning for hepatocellular carcinoma.
Zhang, Yujie; Li, Tingting; Xiao, Han; Ji, Weixing; Guo, Ming; Zeng, Zhaochong; Zhang, Jianying
2018-01-01
To build a knowledge-based model of liver cancer for Auto-Planning, a function in Pinnacle, which is used as an automated inverse intensity modulated radiation therapy (IMRT) planning system. Fifty Tomotherapy patients were enrolled to extract the dose-volume histograms (DVHs) information and construct the protocol for Auto-Planning model. Twenty more patients were chosen additionally to test the model. Manual planning and automatic planning were performed blindly for all twenty test patients with the same machine and treatment planning system. The dose distributions of target and organs at risks (OARs), along with the working time for planning, were evaluated. Statistically significant results showed that automated plans performed better in target conformity index (CI) while mean target dose was 0.5 Gy higher than manual plans. The differences between target homogeneity indexes (HI) of the two methods were not statistically significant. Additionally, the doses of normal liver, left kidney, and small bowel were significantly reduced with automated plan. Particularly, mean dose and V15 of normal liver were 1.4 Gy and 40.5 cc lower with automated plans respectively. Mean doses of left kidney and small bowel were reduced with automated plans by 1.2 Gy and 2.1 Gy respectively. In contrast, working time was also significantly reduced with automated planning. Auto-Planning shows availability and effectiveness in our knowledge-based model for liver cancer. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Effect of staff training on radiation dose in pediatric CT.
Hojreh, Azadeh; Weber, Michael; Homolka, Peter
2015-08-01
To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p<0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p>0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Karlsson, Kristin; Nyman, Jan; Baumann, Pia; Wersäll, Peter; Drugge, Ninni; Gagliardi, Giovanna; Johansson, Karl-Axel; Persson, Jan-Olov; Rutkowska, Eva; Tullgren, Owe; Lax, Ingmar
2013-11-01
To evaluate the dose-response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm(3) up to 2.0 cm(3)]) was statistically evaluated with survival analysis models. Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showed a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm(3) (D(0.1cm3)) was used for further analysis. The median value of D(0.1cm3) (α/β = 3 Gy) was EQD(2,LQ) = 147 Gy3 (range, 20-293 Gy3). For patients who developed atelectasis the median value was EQD(2,LQ) = 210 Gy3, and for patients who did not develop atelectasis, EQD(2,LQ) = 105 Gy3. Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). In this retrospective study a significant dose-response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Abba, Habu Tela; Hassan, Wan Muhamad Saridan Wan; Saleh, Muneer Aziz; Aliyu, Abubakar Sadiq; Ramli, Ahmad Termizi
2017-11-01
In- situ measurement of terrestrial gamma radiation dose rates (TGRD) was conducted in northern zone of Jos Plateau and a statistical relationship between the TGRD and the underlying geological formations was investigated. The TGRD rates in all the measurements ranged from 40 to 1265 nGy h-1 with a mean value of 250 nGy h-1. The maximum TGDR was recorded on geological type G8 (Younger Granites) at Bisitchi, and the lowest TGDR was recorded on G6 (Basaltic rocks) at Gabia. One way analysis of variance (ANOVA) statistical test was used to compared the data. Significantly, the results of this study inferred a strong relationship between TGRD levels with geological structures of a place. An isodose map was plotted to represent exposure rates due to TGRD. The results of this investigation could be useful for multiple public interest such as evaluating public dose for the area.
Variance analysis of x-ray CT sinograms in the presence of electronic noise background.
Ma, Jianhua; Liang, Zhengrong; Fan, Yi; Liu, Yan; Huang, Jing; Chen, Wufan; Lu, Hongbing
2012-07-01
Low-dose x-ray computed tomography (CT) is clinically desired. Accurate noise modeling is a fundamental issue for low-dose CT image reconstruction via statistics-based sinogram restoration or statistical iterative image reconstruction. In this paper, the authors analyzed the statistical moments of low-dose CT data in the presence of electronic noise background. The authors first studied the statistical moment properties of detected signals in CT transmission domain, where the noise of detected signals is considered as quanta fluctuation upon electronic noise background. Then the authors derived, via the Taylor expansion, a new formula for the mean-variance relationship of the detected signals in CT sinogram domain, wherein the image formation becomes a linear operation between the sinogram data and the unknown image, rather than a nonlinear operation in the CT transmission domain. To get insight into the derived new formula by experiments, an anthropomorphic torso phantom was scanned repeatedly by a commercial CT scanner at five different mAs levels from 100 down to 17. The results demonstrated that the electronic noise background is significant when low-mAs (or low-dose) scan is performed. The influence of the electronic noise background should be considered in low-dose CT imaging.
Variance analysis of x-ray CT sinograms in the presence of electronic noise background
Ma, Jianhua; Liang, Zhengrong; Fan, Yi; Liu, Yan; Huang, Jing; Chen, Wufan; Lu, Hongbing
2012-01-01
Purpose: Low-dose x-ray computed tomography (CT) is clinically desired. Accurate noise modeling is a fundamental issue for low-dose CT image reconstruction via statistics-based sinogram restoration or statistical iterative image reconstruction. In this paper, the authors analyzed the statistical moments of low-dose CT data in the presence of electronic noise background. Methods: The authors first studied the statistical moment properties of detected signals in CT transmission domain, where the noise of detected signals is considered as quanta fluctuation upon electronic noise background. Then the authors derived, via the Taylor expansion, a new formula for the mean–variance relationship of the detected signals in CT sinogram domain, wherein the image formation becomes a linear operation between the sinogram data and the unknown image, rather than a nonlinear operation in the CT transmission domain. To get insight into the derived new formula by experiments, an anthropomorphic torso phantom was scanned repeatedly by a commercial CT scanner at five different mAs levels from 100 down to 17. Results: The results demonstrated that the electronic noise background is significant when low-mAs (or low-dose) scan is performed. Conclusions: The influence of the electronic noise background should be considered in low-dose CT imaging. PMID:22830738
Microtensile Bond Strength of Polyacid-modified Composite Resin to Irradiated Primary Molars.
Keles, Sultan; Yilmaz, Yucel; Sezen, Orhan
2018-02-01
This study evaluated the influence of various doses of radiotherapy on the microtensile bond strength (pTBS) of compomer resin to dentin and enamel in primary molars. Thirty-five intact primary molars were collected and divided into seven groups. Teeth were irradiated with doses from 10 to 60 Gy, except for the control group. Compomer restorations were performed, and enamel-compomer resin beams and dentin-compomer resin beams were tested at a crosshead speed of 1 mm/min. No statistically significant difference was found between the irradiated tooth enamel and the control group (F = 1.1468; p = 0.194). However, statistically significant differences were evident among the dentin groups (F = 11.050; p < 0.001). Radiation may not cause a significant difference in the pTBS of compomer resin to primary tooth enamel, but appears to dose dependently decrease its bond strength to primary tooth dentin. Radiotherapy may affect the success rate of compomer fillings in primary teeth, especially in deeper cavities with exposed dentin.
Berry, Donald A.; Ueno, Naoto T.; Johnson, Marcella M.; Lei, Xiudong; Caputo, Jean; Smith, Dori A.; Yancey, Linda J.; Crump, Michael; Stadtmauer, Edward A.; Biron, Pierre; Crown, John P.; Schmid, Peter; Lotz, Jean-Pierre; Rosti, Giovanni; Bregni, Marco; Demirer, Taner
2011-01-01
Purpose High doses of effective chemotherapy are compelling if they can be delivered safely. Substantial interest in supporting high-dose chemotherapy with bone marrow or autologous hematopoietic stem-cell transplantation in the 1980s and 1990s led to the initiation of randomized trials to evaluate its effect in the treatment of metastatic breast cancer. Methods We identified six randomized trials in metastatic breast cancer that evaluated high doses of chemotherapy with transplant support versus a control regimen without stem-cell support. We assembled a single database containing individual patient information from these trials. The primary analysis of overall survival was a log-rank test comparing high dose versus control. We also used Cox proportional hazards regression, adjusting for known covariates. We addressed potential treatment differences within subsets of patients. Results The effect of high-dose chemotherapy on overall survival was not statistically different (median, 2.16 v 2.02 years; P = .08). A statistically significant advantage in progression-free survival (median, 0.91 v 0.69 years) did not translate into survival benefit. Subset analyses found little evidence that there are groups of patients who might benefit from high-dose chemotherapy with hematopoietic support. Conclusion Overall survival of patients with metastatic breast cancer in the six randomized trials was not significantly improved by high-dose chemotherapy; any benefit from high doses was small. No identifiable subset of patients seems to benefit from high-dose chemotherapy. PMID:21768454
Multiscale image processing and antiscatter grids in digital radiography.
Lo, Winnie Y; Hornof, William J; Zwingenberger, Allison L; Robertson, Ian D
2009-01-01
Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.
Morales, Daniel R; Flynn, Rob; Zhang, Jianguo; Trucco, Emmanuel; Quint, Jennifer K; Zutis, Kris
2018-05-01
Several models for predicting the risk of death in people with chronic obstructive pulmonary disease (COPD) exist but have not undergone large scale validation in primary care. The objective of this study was to externally validate these models using statistical and machine learning approaches. We used a primary care COPD cohort identified using data from the UK Clinical Practice Research Datalink. Age-standardised mortality rates were calculated for the population by gender and discrimination of ADO (age, dyspnoea, airflow obstruction), COTE (COPD-specific comorbidity test), DOSE (dyspnoea, airflow obstruction, smoking, exacerbations) and CODEX (comorbidity, dyspnoea, airflow obstruction, exacerbations) at predicting death over 1-3 years measured using logistic regression and a support vector machine learning (SVM) method of analysis. The age-standardised mortality rate was 32.8 (95%CI 32.5-33.1) and 25.2 (95%CI 25.4-25.7) per 1000 person years for men and women respectively. Complete data were available for 54879 patients to predict 1-year mortality. ADO performed the best (c-statistic of 0.730) compared with DOSE (c-statistic 0.645), COTE (c-statistic 0.655) and CODEX (c-statistic 0.649) at predicting 1-year mortality. Discrimination of ADO and DOSE improved at predicting 1-year mortality when combined with COTE comorbidities (c-statistic 0.780 ADO + COTE; c-statistic 0.727 DOSE + COTE). Discrimination did not change significantly over 1-3 years. Comparable results were observed using SVM. In primary care, ADO appears superior at predicting death in COPD. Performance of ADO and DOSE improved when combined with COTE comorbidities suggesting better models may be generated with additional data facilitated using novel approaches. Copyright © 2018. Published by Elsevier Ltd.
Tsuji, Joyce S; Alexander, Dominik D; Perez, Vanessa; Mink, Pamela J
2014-03-20
While exposures to high levels of arsenic in drinking water are associated with excess cancer risk (e.g., skin, bladder, and lung), exposures at lower levels (e.g., <100-200 µg/L) generally are not. Lack of significant associations may result from methodological issues (e.g., inadequate statistical power, exposure misclassification), or a different dose-response relationship at low exposures, possibly associated with a toxicological mode of action that requires a sufficient dose for increased tumor formation. The extent to which bladder cancer risk for low-level arsenic exposure can be statistically measured by epidemiological studies was examined using an updated meta-analysis of bladder cancer risk with data from two new publications. The summary relative risk estimate (SRRE) for all nine studies was elevated slightly, but not significantly (1.07; 95% confidence interval [CI]: 0.95-1.21, p-Heterogeneity [p-H]=0.543). The SRRE among never smokers was 0.85 (95% CI: 0.66-1.08, p-H=0.915), whereas the SRRE was positive and more heterogeneous among ever smokers (1.18; 95% CI: 0.97-1.44, p-H=0.034). The SRRE was statistically significantly lower than relative risks predicted for never smokers in the United States based on linear extrapolation of risks from higher doses in southwest Taiwan to arsenic water exposures >10 µg/L for more than one-third of a lifetime. By contrast, for all study subjects, relative risks predicted for one-half of lifetime exposure to 50 µg/L were just above the upper 95% CI on the SRRE. Thus, results from low-exposure studies, particularly for never smokers, were statistically inconsistent with predicted risk based on high-dose extrapolation. Additional studies that better characterize tobacco use and stratify analyses of arsenic and bladder cancer by smoking status are necessary to further examine risks of arsenic exposure for smokers. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Greenwald, M; Peloso, P M; Mandel, D; Soto, O; Mehta, A; Frontera, N; Boice, J A; Zhan, X J; Curtis, S P
2011-10-01
To further assess the clinically active dose range of etoricoxib, a COX-2 selective inhibitor, in rheumatoid arthritis (RA). RA patients were randomized to etoricoxib 10, 30, 60, or 90 mg or placebo in a double-blind, 12-week study. DMARDs (methotrexate, biologics) or low-dose corticosteroids were allowed in stable doses. The primary endpoint was the proportion of patients completing the study and achieving an American College of Rheumatology 20% (ACR20) response. Secondary endpoints included individual components of the ACR index and Patient Global Assessment of Pain. Safety was assessed by physical exam and adverse experiences (AEs) occurrences. Etoricoxib 90 mg was the only dose to reach a statistically significant difference from placebo (p < 0.001) on the primary endpoint; etoricoxib 60 mg approached significance (p = 0.057). Significant pain improvement vs. placebo was observed with etoricoxib 90 mg (p < 0.001), 60 mg (p = 0.018), and 30 mg (p = 0.017). Despite the use of background biologics and corticosteroids, a dose response was still apparent. A higher proportion of etoricoxib 60 and 90 mg patients had renovascular AEs (i.e., edema and hypertension) compared with placebo, although discontinuations for renovascular AEs were rare. Etoricoxib 90 mg had a higher incidence of serious AEs (n = 5; 1 was considered drug-related) versus placebo (n = 0). The present study was not powered to detect differences in cardiovascular or gastrointestinal safety by dose. Additionally, further research is needed to clarify the role of doses less than the etoricoxib 90 mg dose for pain management in RA patients. Etoricoxib 90 mg demonstrated statistically superior efficacy (ACR20) compared with placebo and numerical superiority over the other doses of etoricoxib studied. Etoricoxib 30 and 60 mg demonstrated significant pain improvement versus placebo, suggesting utility for some patients.
Patro, Satya N; Chakraborty, Santanu; Sheikh, Adnan
2016-01-01
The aim of this study was to evaluate the impact of adaptive statistical iterative reconstruction (ASiR) technique on the image quality and radiation dose reduction. The comparison was made with the traditional filtered back projection (FBP) technique. We retrospectively reviewed 78 patients, who underwent cervical spine CT for blunt cervical trauma between 1 June 2010 and 30 November 2010. 48 patients were imaged using traditional FBP technique and the remaining 30 patients were imaged using the ASiR technique. The patient demographics, radiation dose, objective image signal and noise were recorded; while subjective noise, sharpness, diagnostic acceptability and artefacts were graded by two radiologists blinded to the techniques. We found that the ASiR technique was able to reduce the volume CT dose index, dose-length product and effective dose by 36%, 36.5% and 36.5%, respectively, compared with the FBP technique. There was no significant difference in the image noise (p = 0.39), signal (p = 0.82) and signal-to-noise ratio (p = 0.56) between the groups. The subjective image quality was minimally better in the ASiR group but not statistically significant. There was excellent interobserver agreement on the subjective image quality and diagnostic acceptability for both groups. The use of ASiR technique allowed approximately 36% radiation dose reduction in the evaluation of cervical spine without degrading the image quality. The present study highlights that the ASiR technique is extremely helpful in reducing the patient radiation exposure while maintaining the image quality. It is highly recommended to utilize this novel technique in CT imaging of different body regions.
Dean, K M; Cacela, D; Carney, M W; Cunningham, F L; Ellis, C; Gerson, A R; Guglielmo, C G; Hanson-Dorr, K C; Harr, K E; Healy, K A; Horak, K E; Isanhart, J P; Kennedy, L V; Link, J E; Lipton, I; McFadden, A K; Moye, J K; Perez, C R; Pritsos, C A; Pritsos, K L; Muthumalage, T; Shriner, S A; Bursian, S J
2017-12-01
Scoping studies were designed to determine if double-crested cormorants (Phalacocorax auritus), laughing gulls (Leucophaues atricilla), homing pigeons (Columba livia) and western sandpipers (Calidris mauri) that were gavaged with a mixture of artificially weathered MC252 oil and food for either a single day or 4-5 consecutive days showed signs of oil toxicity. Where volume allowed, samples were collected for hematology, plasma protein electrophoresis, clinical chemistry and electrolytes, oxidative stress and organ weigh changes. Double-crested cormorants, laughing gulls and western sandpipers all excreted oil within 30min of dose, while pigeons regurgitated within less than one hour of dosing. There were species differences in the effectiveness of the dosing technique, with double-crested cormorants having the greatest number of responsive endpoints at the completion of the trial. Statistically significant changes in packed cell volume, white cell counts, alkaline phosphatase, alanine aminotransferase, creatine phosphokinase, gamma glutamyl transferase, uric acid, chloride, sodium, potassium, calcium, total glutathione, glutathione disulfide, reduced glutathione, spleen and liver weights were measured in double-crested cormorants. Homing pigeons had statistically significant changes in creatine phosphokinase, total glutathione, glutathione disulfide, reduced glutathione and Trolox equivalents. Laughing gulls exhibited statistically significant decreases in spleen and kidney weight, and no changes were observed in any measurement endpoints tested in western sandpipers. Copyright © 2017 Elsevier Inc. All rights reserved.
Plappert-Helbig, Ulla; Junker-Walker, Ursula; Martus, Hans-Joerg
2015-07-01
As a part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiative international validation study of the in vivo rat alkaline comet assay (comet assay), we examined methyl methanesulfonate, 2,6-diaminotoluene, and 5-fluorouracil under coded test conditions. Rats were treated orally with the maximum tolerated dose (MTD) and two additional descending doses of the respective compounds. In the MMS treated groups liver and stomach showed significantly elevated DNA damage at each dose level and a significant dose-response relationship. 2,6-diaminotoluene induced significantly elevated DNA damage in the liver at each dose and a statistically significant dose-response relationship whereas no DNA damage was obtained in the stomach. 5-fluorouracil did not induce DNA damage in either liver or stomach. Copyright © 2015 Elsevier B.V. All rights reserved.
Lu, Xinxing; Han, Hu; Xing, Nianzeng; Tian, Long
2015-09-22
To systematically assess the efficacy and safety of oral sildenafil citrate for post bilateral nerve-sparig radical prostatectomy (post-BNSRP) erectile dysfunction (ED). The following keywords: sildenafil, radical prostatectomy were used to search in Medline, Pubmed, Web of Science, Cochrane Library, CNKI, WanFang Database. The title, abstract and keywords of each article were independently screened by two reviewers. Randomized controlled trials (RCT) published between 1990 and 2014 were retrieved according to our inclusion and exclusion criteria. The efficacy and safety of oral sildenafil citrate for post-BNSRP ED were systematically assessed by meta-analysis. Four RCTs with 320 cases were included after literature retrieval and filtering. The potency rates were 32.1% (35/109) and 11.3% (7/62) between sildenafil and placebo groups after meta-analysis and showed statistically significant differences (OR = 4.66, 95% CI: 1.79-12.11). IIEF-5 score in sildenafil group was significant higher than that in the placebo group (WMD: 4.73, 95% CI: 3.26-6.19). In subgroup meta-analysis, the potency rates in high-dose, low-dose sildenafil groups and placebo groups were 30.4% (14/46), 25.0% (10/40) and 4.5% (2/44), respectively. There were statistically significant differences between the high-dose subgroup and placebo group (OR = 9.32, 95% CI: 1.96-44.23), and the low-dose subgroup and placebo group (OR = 6.99, 95% CI: 1.43-34.22). But there was no significant difference between high-dose and low-dose subgroups (OR = 1.31, 95% CI: 0.51-3.40). Compared with placebo, sildenafil has considerable efficacy for erectile function rehabilitationas as a primary treatment for post-BNSRP ED. There is no significant difference between high-dose and low-dose schedule for its efficacy. However, further studies are required to optimize treatment.
Vavrek, Darcy A; Sharma, Rajiv; Haas, Mitchell
2014-06-01
The purpose of this analysis is to report the incremental costs and benefits of different doses of spinal manipulative therapy (SMT) in patients with chronic low back pain (LBP). We randomized 400 patients with chronic LBP to receive a dose of 0, 6, 12, or 18 sessions of SMT. Participants were scheduled for 18 visits for 6 weeks and received SMT or light massage control from a doctor of chiropractic. Societal costs in the year after study enrollment were estimated using patient reports of health care use and lost productivity. The main health outcomes were the number of pain-free days and disability-free days. Multiple regression was performed on outcomes and log-transformed cost data. Lost productivity accounts for most societal costs of chronic LBP. Cost of treatment and lost productivity ranged from $3398 for 12 SMT sessions to $3815 for 0 SMT sessions with no statistically significant differences between groups. Baseline patient characteristics related to increase in costs were greater age (P = .03), greater disability (P = .01), lower quality-adjusted life year scores (P = .01), and higher costs in the period preceding enrollment (P < .01). Pain-free and disability-free days were greater for all SMT doses compared with control, but only SMT 12 yielded a statistically significant benefit of 22.9 pain-free days (P = .03) and 19.8 disability-free days (P = .04). No statistically significant group differences in quality-adjusted life years were noted. A dose of 12 SMT sessions yielded a modest benefit in pain-free and disability-free days. Care of chronic LBP with SMT did not increase the costs of treatment plus lost productivity. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
An in situ caries study on the interplay between fluoride dose and concentration in milk.
Lippert, F; Martinez-Mier, E A; Zero, D T
2014-07-01
This randomized, cross-over in situ study investigated the impact of sodium fluoride dose and concentration in milk on caries lesion rehardening, fluoridation and acid resistance. Twenty-eight subjects wore two gauze-covered enamel specimens with preformed lesions placed buccally on their mandibular partial dentures for three weeks. Participants used fluoride-free dentifrice throughout the study and consumed once daily one of the five study treatments: no fluoride in 200 ml milk (0F-200), 1.5 or 3 mg fluoride in either 100 (1.5F-100; 3F-100) or 200 ml milk (1.5F-200; 3F-200). After three weeks, specimens were retrieved. Knoop hardness was used to determine rehardening and resistance to a secondary acid challenge. Enamel fluoride uptake (EFU) was determined using a microbiopsy technique. A linear fluoride dose-response was observed for all study variables which exhibited similar overall patterns. All the treatments resulted in rehardening, with 0F-200 inducing the least and 3F-100 the most. Apart from 1.5F-200, all the treatments resulted in statistically significantly more rehardening compared to 0F-200. The fluoride doses delivered in 100 ml provided directionally although not statistically significantly more rehardening than those delivered in 200 ml milk. EFU data exhibited better differentiation between treatments: all fluoridated milk treatments delivered more fluoride to lesions than 0F-200; fluoride in 100 ml demonstrated statistically significantly higher EFU than fluoride in 200 ml milk. Findings for acid resistance were also more discerning than rehardening data. The present study has provided further evidence for the anti-caries benefits of fluoridated milk. Both fluoride dose and concentration appear to impact the cariostatic properties of fluoride in milk. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gyanani, Hitesh; Chhabra, Naveen; Parmar, Ghanshyam R
2016-01-01
Study aimed to evaluate the efficacy of two different pretreatment single oral doses of betamethasone on the incidence of inter-appointment flare up and postoperative discomfort. Fifty-four patients aged 18-59 years requiring endodontic treatment were selected and randomly assigned to three groups; single pretreatment oral dose of placebo or betamethasone in two different oral doses of 0.5 mg and 1 mg, respectively. Endodontic therapy was completed in two visits using triple antibiotic paste as intracanal medicament. Patients were given a questionnaire to record their pain at 1, 2, 3, and 7 days after treatment. In the second visit, obturation was done, and the patients were again instructed to record their pain scores after treatment and discharged. The verbal rating scale was used for recording the pain scores. Statistical analysis was done using ANOVA and the Friedman test. 0.5 mg betamethasone group showed least mean pain scores among all experimental groups; however, there was no statistically significant difference between any of the groups ( P > 0.05). Pretreatment single oral dose of betamethasone is an effective in managing endodontic flare-ups; however, the results were statistically insignificant.
Kaplan, Volkan; Eroğlu, Cennet Neslihan
2016-10-01
The aim of the present study was to compare the effects of daily single-dose use of flurbiprofen, diclofenac sodium, and tenoxicam on pain, swelling, and trismus that occur after surgical extraction of impacted wisdom teeth using local anesthesia. The present study included 3 groups with 30 patients in each group. Those volunteering to participate in this double-blind randomized study (n = 90) were selected from a patient population with an indication for extraction of impacted wisdom teeth. Group 1 patients received 200 mg flurbiprofen, group 2 patients received 100 mg diclofenac sodium, and group 3 patients received 20 mg tenoxicam. All doses were once a day, starting preoperatively. Pain was evaluated postoperatively at 1, 2, 3, 6, 8, and 24 hours and at 2 and 7 days using a visual analog scale (VAS). For comparison with the preoperative measurements, the patients were invited to postoperative follow-up visits 2 and 7 days after extraction to evaluate for swelling and trismus. The statistical analysis was performed using descriptive statistics in SAS, version 9.4 (SAS Institute, Cary, NC), software. Statistical analysis of the pain, swelling, and trismus data was performed using the Kruskal-Wallis, Dunn, and Wilcoxon-Mann-Whitney U tests. The statistical level of significance was accepted at P = .05 and power of 0.80. Clinically, tenoxicam showed better analgesic and anti-inflammatory efficacy compared with diclofenac sodium and, in particular, flurbiprofen. Although the VAS scores in the evaluation of pain showed statistically significant differences at 2 days, no statistically significant difference was found for swelling and trismus. Our study evaluated the analgesic and anti-inflammatory effects with a daily single dose of flurbiprofen, diclofenac sodium, and tenoxicam. Daily 20 mg tenoxicam can be accepted as an adequate and safe option for patients after a surgical procedure. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
The Utility of Low-Dose Aripiprazole for the Treatment of Bipolar II and Bipolar NOS Depression.
Kelly, Tammas; Lieberman, Daniel Z
2017-02-01
Despite initial reports of efficacy in bipolar depression, multicenter trials did not show aripiprazole to be better than placebo, possibly because the doses used were too high, leading to lower efficacy and high dropout rates. This study evaluated the effects of low-dose aripiprazole. Extensive clinical experience has suggested that doses beyond 5 mg are rarely efficacious. Data were gathered from patients with bipolar II or bipolar not otherwise specified depression using a retrospective chart review. Efficacy was assessed with the Clinical Global Impression-Improvement score. Patients who had at least 2 trials of aripiprazole were included in a retrospective off-on-off-on experimental design. All patients were on other medications when aripiprazole was started. Patients were treated with doses of 1 to 5 mg. On average, patients were rated improved or very much improved compared with baseline. Sixteen of 211 patients worsened or experienced no change. Forty-four patients (21%) discontinued due to adverse effects. The group of patients who underwent off-on-off-on trials experienced statistically significant improvement when they started and restarted aripiprazole, and statistically significant worsening when they discontinued it. When treating bipolar II or bipolar not otherwise specified depression, low doses of aripiprazole, 5 mg or less, may be more effective and better tolerated than higher ones. Clinicians should start treatment with a very low dose and give patients time to respond.
ERIC Educational Resources Information Center
Mulhern, Raymond, K; And Others
1992-01-01
Assessed association of young age at treatment, cranial irradiation, and time since treatment with intellectual deterioration among 49 long-term survivors of childhood leukemia. Found no significant effects of treatment group (low-dose cranial irradiation versus high-dose chemotherapy) or age at treatment. Small but statistically significant…
Benz, Dominik C; Gräni, Christoph; Mikulicic, Fran; Vontobel, Jan; Fuchs, Tobias A; Possner, Mathias; Clerc, Olivier F; Stehli, Julia; Gaemperli, Oliver; Pazhenkottil, Aju P; Buechel, Ronny R; Kaufmann, Philipp A
The clinical utility of a latest generation iterative reconstruction algorithm (adaptive statistical iterative reconstruction [ASiR-V]) has yet to be elucidated for coronary computed tomography angiography (CCTA). This study evaluates the impact of ASiR-V on signal, noise and image quality in CCTA. Sixty-five patients underwent clinically indicated CCTA on a 256-slice CT scanner using an ultralow-dose protocol. Data sets from each patient were reconstructed at 6 different levels of ASiR-V. Signal intensity was measured by placing a region of interest in the aortic root, LMA, and RCA. Similarly, noise was measured in the aortic root. Image quality was visually assessed by 2 readers. Median radiation dose was 0.49 mSv. Image noise decreased with increasing levels of ASiR-V resulting in a significant increase in signal-to-noise ratio in the RCA and LMA (P < 0.001). Correspondingly, image quality significantly increased with higher levels of ASiR-V (P < 0.001). ASiR-V yields substantial noise reduction and improved image quality enabling introduction of ultralow-dose CCTA.
Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom
Davies, J; Horner, K; Theodorakou, C
2015-01-01
Objectives: The purpose of the study is to evaluate the effectiveness of thyroid shielding in dental CBCT examinations using a paediatric anthropomorphic phantom. Methods: An ATOM® 706-C anthropomorphic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA) representing a 10-year-old child was loaded with six thermoluminescent dosemeters positioned at the level of the thyroid gland. Absorbed doses to the thyroid were measured for five commercially available thyroid shields using a large field of view (FOV). Results: A statistically significant thyroid gland dose reduction was found using thyroid shielding for paediatric CBCT examinations for a large FOV. In addition, a statistically significant difference in thyroid gland doses was found depending on the position of the thyroid gland. There was little difference in the effectiveness of thyroid shielding when using a lead vs a lead-equivalent thyroid shield. Similar dose reduction was found using 0.25- and 0.50-mm lead-equivalent thyroid shields. Conclusions: Thyroid shields are to be recommended when undertaking large FOV CBCT examinations on young patients. PMID:25411710
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cammin, J; Curcuru, A; Li, H
Purpose: To compare depth-dose and surface-dose measurements without and with the magnetic field in a 0.3T MR image-guided Co-60 treatment unit using MOSFET dosimeters. Methods: MOSFET dosimeters (Best Medical Canada, model TN-502RDH-10) were placed in a solid water phantom at 5cm depth with 8cm backscatter (with the MOSFET wires in different orientations to the couch long axis) and also on the surface of an 8cm solid water phantom. The phantoms were placed in an MR image-guided Co-60 treatment machine at an SAD of 105cm to the MOSFETs. Dose measurements were performed between 50 and 200cGy at 5cm depth in amore » 10.5cm × 10.5cm radiation field without the magnetic field (during a machine maintenance period) and with the nominal magnetic field of 0.3T. The dose linearity was measured at 5cm depth with an orthogonal field and the angular dose dependence was measured on the surface with an orthogonal field and oblique fields at +60 degrees and −60 degrees. Results: The measured MOSFET readings at 5cm depth were linear with dose with slopes of (2.97 +/− 0.01) mV/cGy and (3.01 +/− 0.02) mV/cGy without and with the magnetic field, respectively. No statistically significant difference was found. The surface dose measurements, however, were lower by 6.4% for the AP field (2.3 σ) with magnetic field, 4.9% for the −60 degree field (1.4 σ), and 0.4% different for the +60 degree field (0.2 σ). Conclusion: There is no statistically significant difference in the dose at depth without and with the magnetic field and different orientations of the MOSFET wires. There is a statistically significant difference for the surface dose due to the influence of the magnetic field on secondary electrons from head-scatter and the build-up region in certain field orientations. Clinical surface-dose dosimetry in a magnetic field should apply asymmetric angle-dependent corrections.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, X; Sun, T; Liu, T
2014-06-01
Purpose: To evaluate the dosimetric characteristics of intensity-modulated radiotherapy (IMRT) treatment plan with beam angle optimization. Methods: Ten post-operation patients with cervical cancer were included in this analysis. Two IMRT plans using seven beams were designed in each patient. A standard coplanar equi-space beam angles were used in the first plan (plan 1), whereas the selection of beam angle was optimized by beam angle optimization algorithm in Varian Eclipse treatment planning system for the same number of beams in the second plan (plan 2). Two plans were designed for each patient with the same dose-volume constraints and prescription dose. Allmore » plans were normalized to the mean dose to PTV. The dose distribution in the target, the dose to the organs at risk and total MU were compared. Results: For conformity and homogeneity in PTV, no statistically differences were observed in the two plans. For the mean dose in bladder, plan 2 were significantly lower than plan 1(p<0.05). No statistically significant differences were observed between two plans for the mean doses in rectum, left and right femur heads. Compared with plan1, the average monitor units reduced 16% in plan 2. Conclusion: The IMRT plan based on beam angle optimization for cervical cancer could reduce the dose delivered to bladder and also reduce MU. Therefore there were some dosimetric advantages in the IMRT plan with beam angle optimization for cervical cancer.« less
Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John
2011-04-01
Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.
Testing the effects of long-acting steroids in edema and ecchymosis after closed rhinoplasty
Gutierrez, Santiago; Wuesthoff, Carolina
2014-01-01
BACKGROUND: Steroids have proven to be of some benefit in rhinoplasty edema and ecchymosis when administered at a high and repeated dose. OBJECTIVE: To evaluate the effects of single-dose, long-acting intramuscular steroids on postoperative edema and ecchymosis after closed rhinoplasty with osteotomies compared with placebo. METHODS: A randomized, double-blinded, placebo-controlled trial was performed. Fifty-four patients were randomly assigned to two groups: 28 received a single dose of long-acting dexamethasone (mean [± SD] dose 16±4 mg) immediately before anesthetic induction; the remaining 26 received an intramuscular injection of saline solution. The same surgeon performed all surgeries, with patients under general anesthesia. Acetaminophen was the only analgesic used to control postoperative pain. High-resolution digital photographs were taken on postoperative days 1, 3, 7 and 14. Scoring was performed separately for eyelid swelling and ecchymosis by an independent observer using a graded scale (0 to 5) for edema and a scoring system (0 to 13) for ecchymosis. RESULTS: No statistically significant differences in terms of age, sex or amount of bleeding during surgery were found between the two groups. No statistically significant difference was observed in the decrease of both ecchymosis and edema between placebo and high-dose, long-acting dexamethasone. A statistically significant difference in operation time was found, favouring the steroid group. No severe complications were observed due to steroid use. DISCUSSION: Osteotomies are basically a form of (controlled) trauma, with considerable disruption of the abundant blood vessels in this facial region and, therefore, are associated with with undesirable effects. A recent meta-analysis failed to show benefits of the use of steroids after postoperative day 3. Only a trend toward reduction in edema and ecchymosis with the use of long-acting steroids compared with placebo was demonstrated in the present study. CONCLUSION: There was no benefit in administering single-dose, long-acting steroids in patients undergoing closed rhinoplasty with osteotomies. PMID:25114618
Nolan, Emily R; Feng, Meihua Rose; Koup, Jeffrey R; Liu, Jing; Turluck, Daniel; Zhang, Yiqun; Paulissen, Jerome B; Olivier, N Bari; Miller, Teresa; Bailie, Marc B
2006-01-01
Terfenadine, cisapride, and E-4031, three drugs that prolong ventricular repolarization, were selected to evaluate the sensitivity of the conscious chronic atrioventricular node--ablated, His bundle-paced Dog for defining drug induced cardiac repolarization prolongation. A novel predictive pharmacokinetic/pharmacodynamic model of repolarization prolongation was generated from these data. Three male beagle dogs underwent radiofrequency AV nodal ablation, and placement of a His bundle-pacing lead and programmable pacemaker under anesthesia. Each dog was restrained in a sling for a series of increasing dose infusions of each drug while maintained at a constant heart rate of 80 beats/min. RT interval, a surrogate for QT interval in His bundle-paced dogs, was recorded throughout the experiment. E-4031 induced a statistically significant RT prolongation at the highest three doses. Cisapride resulted in a dose-dependent increase in RT interval, which was statistically significant at the two highest doses. Terfenadine induced a dose-dependent RT interval prolongation with a statistically significant change occurring only at the highest dose. The relationship between drug concentration and RT interval change was described by a sigmoid E(max) model with an effect site. Maximum RT change (E(max)), free drug concentration at half of the maximum effect (EC(50)), and free drug concentration associated with a 10 ms RT prolongation (EC(10 ms)) were estimated. A linear correlation between EC(10 ms) and HERG IC(50) values was identified. The conscious dog with His bundle-pacing detects delayed cardiac repolarization related to I(Kr) inhibition, and detects repolarization change induced by drugs with activity at multiple ion channels. A clinically relevant sensitivity and a linear correlation with in vitro HERG data make the conscious His bundle-paced dog a valuable tool for detecting repolarization effect of new chemical entities.
Jurković, Drazen; Stimac, Danijela; Bajramović, Dubravko; Tiljak, Hrvoje; Stevanović, Ranko
2014-06-01
The aim of this paper is to determine the differences in the outpatient consumption of cardiovascular drugs between Croatian regions: the City of Zagreb and Lika-Senj County. The data on the number of packages and the purchase price for each drug have been obtained from all pharmacies in Lika-Senj County and all pharmacies in the City of Zagreb. Defined daily doses/1000 inhabitants/day (DDD/1000/day) was calculated for every drug in accordance with its code name and Anatomical Therapeutic Chemical/Defined Daily Dose (ATC/DDD) index of the World Health Organization (WHO) for 2007. For drug combinations without defined daily doses, equivalent doses (ED) were used. The quality of drug prescribing within the group of cardiovascular drugs was assessed using the Drug Utilization (DU90%) method and the adherence of the DU90% segment to the guidelines for prescribing individual drug groups. The statistical significance of differences in results between the City of Zagreb and Lika-Senj County was tested using the chi-square test at the level of statistical significance p < 0.05. The comparison of the share of the five most often prescribed drug groups in Lika-Senj County has shown statistically significant differences when compared to the City of Zagreb (chi2 = 28.93, df = 4, p < 0.001). The total outpatient consumption of cardiovascular drugs in the City of Zagreb and Lika-Senj County differs significantly. The consumption, quality of prescribing drugs and cost/DDD in the City of Zagreb is higher than in Lika-Senj County; in the City of Zagreb, newer and more expensive drugs are prescribed to a higher extent.
Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100kVp.
Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Allmendinger, Thomas; Schoenberg, Stefan O; Henzler, Thomas
2015-08-01
To prospectively investigate image quality and radiation dose of 100kVp spectral shaping chest CT using a dedicated tin filter on a 3rd generation dual-source CT (DSCT) in comparison to standard 100kVp chest CT. Sixty patients referred for a non-contrast chest on a 3rd generation DSCT were prospectively included and examined at 100kVp with a dedicated tin filter. These patients were retrospectively matched with patients that were examined on a 2nd generation DSCT at 100kVp without tin filter. Objective and subjective image quality was assessed in various anatomic regions and radiation dose was compared. Radiation dose was decreased by 90% using the tin filter (3.0 vs 0.32mSv). Soft tissue attenuation and image noise was not statistically different for both examination techniques (p>0.05), however image noise was found to be significantly higher in the trachea when using the additional tin filter (p=0.002). SNR was found to be statistically similar in pulmonary tissue, significantly lower when measured in air and significantly higher in the aorta for the scans on the 3rd generation DSCT. Subjective image quality with regard to overall quality and image noise and sharpness was not statistically significantly different (p>0.05). 100kVp spectral shaping chest CT by means of a tube-based tin-filter on a 3rd generation DSCT allows 90% dose reduction when compared to 100kVp chest CT on a 2nd generation DSCT without spectral shaping. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Schoedel, Kerri A; Andreas, Jens-Otto; Doty, Pamela; Eckhardt, Klaus; Sellers, Edward M
2017-12-01
This phase 1, randomized, double-blind, placebo- and active comparator-controlled crossover study assessed the abuse potential of the antiepileptic drug, lacosamide. After a qualification phase, 38 healthy, recreational central nervous system-depressant users were randomized to treatment sequences comprising single oral therapeutic (200 mg) and supratherapeutic (800 mg) doses of lacosamide, alprazolam (1.5 and 3 mg), and placebo. Subjective effects were assessed for 24 hours following each dose using a range of scales, with a 5- to 9-day washout between treatments. Mean subjective effects for 200 mg lacosamide were statistically similar to placebo and significantly lower than with alprazolam for most end points. Lacosamide 800 mg elicited transient, statistically significant positive effects compared with placebo, but also persistent Bad Drug Effects including statistically greater maximum effect (Emax) scores for Nausea and Dysphoria compared with other treatments (P < 0.0002). Consistent with this, the 800 mg lacosamide dose showed a significantly lower "at this moment" Drug Liking visual analog scale (VAS) Emax compared with 3 mg alprazolam, but was not different from 1.5 mg alprazolam (73.1/100, 85.4/100, and 78.9/100, respectively, where 50 is neutral). Overall Drug Liking VAS and Take Drug Again VAS Emax for 800 mg lacosamide were not significantly different from placebo and were lower than those for both alprazolam doses (P < 0.0001). These results suggest that in recreational central nervous system-depressant users, lacosamide has detectable abuse-related subjective effects, but a relatively low potential for abuse compared with alprazolam. These findings contributed toward placement of lacosamide into Schedule V of the US Controlled Substances Act.
Effects of atomoxetine on the QT interval in healthy CYP2D6 poor metabolizers
Loghin, Corina; Haber, Harry; Beasley, Charles M; Kothare, Prajakti A; Kauffman, Lynnette; April, John; Jin, Ling; Allen, Albert J; Mitchell, Malcolm I
2013-01-01
Aim The effects of atomoxetine (20 and 60 mg twice daily), 400 mg moxifloxacin and placebo on QTc in 131 healthy CYP2D6 poor metabolizer males were compared. Methods Atomoxetine doses were selected to result in plasma concentrations that approximated expected plasma concentrations at both the maximum recommended dose and at a supratherapeutic dose in CYP2D6 extensive metabolizers. Ten second electrocardiograms were obtained for time-matched baseline on days −2 and −1, three time points after dosing on day 1 for moxifloxacin and five time points on day 7 for atomoxetine and placebo. Maximum mean placebo-subtracted change from baseline model-corrected QT (QTcM) on day 7 was the primary endpoint. Results QTcM differences for atomoxetine 20 and 60 mg twice daily were 0.5 ms (upper bound of the one-sided 95% confidence interval 2.2 ms) and 4.2 ms (upper bound of the one-sided 95% confidence interval 6.0 ms), respectively. As plasma concentration of atomoxetine increased, a statistically significant increase in QTc was observed. The moxifloxacin difference from placebo met the a priori definition of non-inferiority. Maximum mean placebo-subtracted change from baseline QTcM for moxifloxacin was 4.8 ms and this difference was statistically significant. Moxifloxacin plasma concentrations were below the concentrations expected from the literature. However, the slope of the plasma concentration−QTc change observed was consistent with the literature. Conclusion Atomoxetine was not associated with a clinically significant change in QTc. However, a statistically significant increase in QTc was associated with increasing plasma concentrations. PMID:22803597
Goldman, S A
1996-10-01
Neurotoxicity in relation to concomitant administration of lithium and neuroleptic drugs, particularly haloperidol, has been an ongoing issue. This study examined whether use of lithium with neuroleptic drugs enhances neurotoxicity leading to permanent sequelae. The Spontaneous Reporting System database of the United States Food and Drug Administration and extant literature were reviewed for spectrum cases of lithium/neuroleptic neurotoxicity. Groups taking lithium alone (Li), lithium/haloperidol (LiHal) and lithium/ nonhaloperidol neuroleptics (LiNeuro), each paired for recovery and sequelae, were established for 237 cases. Statistical analyses included pairwise comparisons of lithium levels using the Wilcoxon Rank Sum procedure and logistic regression to analyze the relationship between independent variables and development of sequelae. The Li and Li-Neuro groups showed significant statistical differences in median lithium levels between recovery and sequelae pairs, whereas the LiHal pair did not differ significantly. Lithium level was associated with sequelae development overall and within the Li and LiNeuro groups; no such association was evident in the LiHal group. On multivariable logistic regression analysis, lithium level and taking lithium/haloperidol were significant factors in the development of sequelae, with multiple possibly confounding factors (e.g., age, sex) not statistically significant. Multivariable logistic regression analyses with neuroleptic dose as five discrete dose ranges or actual dose did not show an association between development of sequelae and dose. Database limitations notwithstanding, the lack of apparent impact of serum lithium level on the development of sequelae in patients treated with haloperidol contrasts notably with results in the Li and LiNeuro groups. These findings may suggest a possible effect of pharmacodynamic factors in lithium/neuroleptic combination therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bossart, E; Monterroso, M; Couto, M
Purpose: Dosimetrically compare CyberKnife (CK) and linac-based (LB) stereotactic body radiotherapy (SBRT) plans for lumbar spine. Methods: Ten patient plans with lumbar spine tumors treated with CK were selected and retrospectively optimized using three techniques: CK, volumetric modulated arc (VMAT, three arcs), and 9-field-intensity modulated radiotherapy (IMRT). For the LB plans, the target volume was expanded by 1mm to accommodate additional uncertainty in patient positioning. All plans were optimized to a prescription dose of 27Gy in 3 fractions covering 90% of the PTV. If the dose constraints to the cauda equina (cauda) were not met, the prescription dose was loweredmore » to 24Gy. Parameters evaluated included Paddick Conformity-Index (CI) and Gradient-Index (GI). A two-tailed paired t-test was used to establish statistically significant differences in cauda doses. Results: Target volumes for LB plans were on average 38% larger. In terms of the indices, the closer the index values to unity the steeper the dose falloff and the higher the dose conformity to the target. The results showed that LB plans were in general statistically superior to CK plans. The IMRT plan showed the best average gradient index of 2.995, with VMAT and CK GI values of 3.699 and 5.476, respectively. Similarly, the same trend occurs with the average CI results: 0.821, 0.814, and 0.758, corresponding to IMRT, VMAT, and CK. Notably, in one CK plan the target dose was reduced to 24Gy to meet cauda constraints. Additionally, there was a statistically significant dose difference for the cauda between the CK and LB plans. Conclusion: This study demonstrates that LB plans for lumbar spine SBRT can be as effective or even better than CK plans. Despite the expansion of the target volume, the LB plans did not demonstrate dosimetric inferiority. The LB plans Resultin 2-to-3 fold decrease of treatment time.« less
Gatti, Marco; Marchisio, Filippo; Fronda, Marco; Rampado, Osvaldo; Faletti, Riccardo; Bergamasco, Laura; Ropolo, Roberto; Fonio, Paolo
The aim of this study was to evaluate the impact on dose reduction and image quality of the new iterative reconstruction technique: adaptive statistical iterative reconstruction (ASIR-V). Fifty consecutive oncologic patients acted as case controls undergoing during their follow-up a computed tomography scan both with ASIR and ASIR-V. Each study was analyzed in a double-blinded fashion by 2 radiologists. Both quantitative and qualitative analyses of image quality were conducted. Computed tomography scanner radiation output was 38% (29%-45%) lower (P < 0.0001) for the ASIR-V examinations than for the ASIR ones. The quantitative image noise was significantly lower (P < 0.0001) for ASIR-V. Adaptive statistical iterative reconstruction-V had a higher performance for the subjective image noise (P = 0.01 for 5 mm and P = 0.009 for 1.25 mm), the other parameters (image sharpness, diagnostic acceptability, and overall image quality) being similar (P > 0.05). Adaptive statistical iterative reconstruction-V is a new iterative reconstruction technique that has the potential to provide image quality equal to or greater than ASIR, with a dose reduction around 40%.
Kreuzer, M; Straif, K; Marsh, J W; Dufey, F; Grosche, B; Nosske, D; Sogl, M
2012-03-01
'Dusty occupations' and exposure to low-dose radiation have been suggested as potential risk factors for stomach cancer. Data from the German uranium miner cohort study are used to further evaluate this topic. The cohort includes 58 677 miners with complete information on occupational exposure to dust, arsenic and radiation dose based on a detailed job-exposure matrix. A total of 592 stomach cancer deaths occurred in the follow-up period from 1946 to 2003. A Poisson regression model stratified by age and calendar year was used to calculate the excess relative risk (ERR) per unit of cumulative exposure to fine dust or from cumulative absorbed dose to stomach from α or low-LET (low linear energy transfer) radiation. For arsenic exposure, a binary quadratic model was applied. After adjustment for each of the three other variables, a statistically non-significant linear relationship was observed for absorbed dose from low-LET radiation (ERR/Gy=0.30, 95% CI -1.26 to 1.87), α radiation (ERR/Gy=22.5, 95% CI -26.5 to 71.5) and fine dust (ERR/dust-year=0.0012, 95% CI -0.0020 to 0.0043). The relationship between stomach cancer and arsenic exposure was non-linear with a 2.1-fold higher RR (95% CI 0.9 to 3.3) in the exposure category above 500 compared with 0 dust-years. Positive statistically non-significant relationships between stomach cancer and arsenic dust, fine dust and absorbed dose from α and low-LET radiation were found. Overall, low statistical power due to low doses from radiation and dust are of concern.
Sheikh, Adnan
2016-01-01
Objective: The aim of this study was to evaluate the impact of adaptive statistical iterative reconstruction (ASiR) technique on the image quality and radiation dose reduction. The comparison was made with the traditional filtered back projection (FBP) technique. Methods: We retrospectively reviewed 78 patients, who underwent cervical spine CT for blunt cervical trauma between 1 June 2010 and 30 November 2010. 48 patients were imaged using traditional FBP technique and the remaining 30 patients were imaged using the ASiR technique. The patient demographics, radiation dose, objective image signal and noise were recorded; while subjective noise, sharpness, diagnostic acceptability and artefacts were graded by two radiologists blinded to the techniques. Results: We found that the ASiR technique was able to reduce the volume CT dose index, dose–length product and effective dose by 36%, 36.5% and 36.5%, respectively, compared with the FBP technique. There was no significant difference in the image noise (p = 0.39), signal (p = 0.82) and signal-to-noise ratio (p = 0.56) between the groups. The subjective image quality was minimally better in the ASiR group but not statistically significant. There was excellent interobserver agreement on the subjective image quality and diagnostic acceptability for both groups. Conclusion: The use of ASiR technique allowed approximately 36% radiation dose reduction in the evaluation of cervical spine without degrading the image quality. Advances in knowledge: The present study highlights that the ASiR technique is extremely helpful in reducing the patient radiation exposure while maintaining the image quality. It is highly recommended to utilize this novel technique in CT imaging of different body regions. PMID:26882825
Efficiency and Safety of Prolonged Levosimendan Infusion in Patients with Acute Heart Failure
Aidonidis, Georgios; Kanonidis, Ioannis; Koutsimanis, Vasileios; Neumann, Till; Erbel, Raimund; Sakadamis, Georgios
2011-01-01
Background. Levosimendan is an inotropic drug with unique pharmacological advantages in patients with acute heart failure. Scope of this study is to determine whether longer infusion patterns without the hypotension-inducing loading dose could justify an effective and safe alternative approach. Methods. 70 patients admitted to the emergencies with decompensated chronic heart failure received intravenously levosimendan without a loading dose up to 72 hours. Clinical parameters, BNP (Brain Natriuretic Peptide) and signal-averaged-ECG data (SAECG) were recorded up to 72 hours. Results. The 48-hour group demonstrated a statistically significant BNP decrease (P < .001) after 48 hours, which also maintained after 72 hours. The 72-hour group demonstrated a bordeline decrease of BNP after 48 hours (P = .039), necessitating an additional 24-hour infusion to achieve significant reduction after 72 hours (P < .004). SAECG data demonstrated a statistically significant decrease after 72 hours (P < .04). Apart from two deaths due to advanced heart failure, no major complications were observed. Conclusion. Prolonged infusion of levosimendan without a loading dose is associated with an acceptable clinical and neurohumoral response. PMID:21559263
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karlsson, Kristin, E-mail: kristin.karlsson@karolinska.se; Department of Oncology-Pathology, Karolinska Institute, Stockholm; Nyman, Jan
2013-11-01
Purpose: To evaluate the dose–response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Methods and Materials: Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm{sup 3} up to 2.0 cm{sup 3}]) was statistically evaluated with survival analysis models. Results: Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showedmore » a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm{sup 3} (D{sub 0.1cm3}) was used for further analysis. The median value of D{sub 0.1cm3} (α/β = 3 Gy) was EQD{sub 2,LQ} = 147 Gy{sub 3} (range, 20-293 Gy{sub 3}). For patients who developed atelectasis the median value was EQD{sub 2,LQ} = 210 Gy{sub 3}, and for patients who did not develop atelectasis, EQD{sub 2,LQ} = 105 Gy{sub 3}. Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). Conclusion: In this retrospective study a significant dose–response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sayah, N; Weiss, E; Watkins, W
Purpose: To evaluate the dose-mapping error (DME) inherent to conventional dose-mapping algorithms as a function of dose-matrix resolution. Methods: As DME has been reported to be greatest where dose-gradients overlap tissue-density gradients, non-clinical 66 Gy IMRT plans were generated for 11 lung patients with the target edge defined as the maximum 3D density gradient on the 0% (end of inhale) breathing phase. Post-optimization, Beams were copied to 9 breathing phases. Monte Carlo dose computed (with 2*2*2 mm{sup 3} resolution) on all 10 breathing phases was deformably mapped to phase 0% using the Monte Carlo energy-transfer method with congruent mass-mapping (EMCM);more » an externally implemented tri-linear interpolation method with voxel sub-division; Pinnacle’s internal (tri-linear) method; and a post-processing energy-mass voxel-warping method (dTransform). All methods used the same base displacement-vector-field (or it’s pseudo-inverse as appropriate) for the dose mapping. Mapping was also performed at 4*4*4 mm{sup 3} by merging adjacent dose voxels. Results: Using EMCM as the reference standard, no clinically significant (>1 Gy) DMEs were found for the mean lung dose (MLD), lung V20Gy, or esophagus dose-volume indices, although MLD and V20Gy were statistically different (2*2*2 mm{sup 3}). Pinnacle-to-EMCM target D98% DMEs of 4.4 and 1.2 Gy were observed ( 2*2*2 mm{sup 3}). However dTransform, which like EMCM conserves integral dose, had DME >1 Gy for one case. The root mean square RMS of the DME for the tri-linear-to- EMCM methods was lower for the smaller voxel volume for the tumor 4D-D98%, lung V20Gy, and cord D1%. Conclusion: When tissue gradients overlap with dose gradients, organs-at-risk DME was statistically significant but not clinically significant. Target-D98%-DME was deemed clinically significant for 2/11 patients (2*2*2 mm{sup 3}). Since tri-linear RMS-DME between EMCM and tri-linear was reduced at 2*2*2 mm{sup 3}, use of this resolution is recommended for dose mapping. Interpolative dose methods are sufficiently accurate for the majority of cases. J.V. Siebers receives funding support from Varian Medical Systems.« less
Experimental re-evaluation of flunarizine as add-on antiepileptic therapy.
Thakur, Anamika; Sahai, A K; Thakur, J S
2011-04-01
Experimental studies have found several calcium channel blockers with anticonvulsant property. Flunarizine is one of the most potent calcium channel blockers, which has shown anticonvulsant effect against pentylenetetrazole (PTZ) and maximal electroshock (MES)-induced seizures. However, further experimental and clinical trials have shown varied results. We conducted a PTZ model experimental study to re-evaluate the potential of flunarizine for add-on therapy in the management of refractory epilepsy. Experiments were conducted in PTZ model involving Swiss strain mice. Doses producing seizures in 50% and 99% mice, i.e. CD(50) and CD(99) values of PTZ were obtained from the dose-response study. Animals received graded, single dose of sodium valproate (100-300 mg/kg), lamotrigine (3-12 mg/kg) and flunarizine (5-20 mg/kg), and then each group of mice was injected with CD(99) dose of PTZ (65mg/kg i.p.). Another group of mice received single ED(50) dose (dose producing seizure protection in 50% mice) of sodium valproate and flunarizine separately in left and right side of abdomen. Results were analysed by Kruskal-Wallis ANOVA on Ranks test. As compared to control, sodium valproate at 250 mg/kg and 300 mg/kg produced statistical significant seizure protection. At none of the pre-treatment dose levels of lamotrigine, the seizure score with PTZ differed significantly from that observed in the vehicle-treated group. Pre-treatment with flunarizine demonstrated dose-dependent decrease in the seizure score to PTZ administration. As compared to control group, flunarizine at 20 mg/kg produced statistical significant seizure protection. As combined use of sodium valproate and flunarizine has shown significant seizure protection in PTZ model, flunarizine has a potential for add-on therapy in refractory cases of partial seizures. It is therefore, we conclude that further experimental studies and multicenter clinical trials involving large sample size are needed to establish flunarizine as add-on therapy in refractory epilepsy.
Galantamine for Alzheimer's disease.
Olin, J; Schneider, L
2002-01-01
Galantamine (also called galanthamine, marketed by Janssen as Reminyl) was originally isolated from several plants, including daffodil bulbs, but is now synthesized. Galantamine is a specific, competitive, and reversible acetylcholinesterase inhibitor. It is also an allosteric modulator at nicotinic cholinergic receptor sites potentiating cholinergic nicotinic neurotransmission. A small number of early studies showed mild cognitive and global benefits for patients with Alzheimer's disease (AD), and recently several multicentre clinical trials have been published with positive findings. Galantamine has received regulatory approval in 29 counties: Argentina, Australia, Canada, Czechia, the European Union (except for The Netherlands), Iceland, Korea, Mexico, Norway, Poland, Singapore, South Africa, Switzerland, Thailand, and the United States. The objective of this overview is to assess the clinical effects of galantamine in patients with probable AD, and to investigate potential moderators of an effect. The trials were identified from a search of the Specialized Register of the Cochrane Dementia and Cognitive Improvement Group on 15 May 2002 using the terms galantamine and Reminyl. Published reviews were inspected for further sources. Additional information was collected from an unpublished investigational brochure for galantamine. Trials selected were randomized, double-blind, parallel-group, unconfounded comparisons of galantamine with placebo for a treatment duration of greater than 4 weeks for people with AD. Data were extracted independently by the reviewers and pooled where appropriate and possible. The pooled odds ratios (95%CI) or the average differences (95%CI) were estimated. Intention-to-treat and observed cases data were both reported, if the data were available. Outcomes of interest include the Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog), clinical global impression of change (CIBIC-plus or CGIC), Alzheimer's Disease Cooperative Study Activities of Daily Living Scale (ADCS-ADL), Disability Assessment for Dementia scale (DAD) and Neuropsychiatric Inventory (NPI). Potential moderating variables of a treatment effect included trial duration and dose. Seven trials were identified that met criteria for entry, with six being Phase II or III industry-sponsored multicentre trials. Two were of 12 weeks duration; one of 13 weeks, one of 5 months; one of 29 weeks; and two of 6 months duration. Trials of 5 months or more were aggregated together in the analyses as '6 months.' Overall, galantamine showed significant treatment effects at daily doses of 16-32 mg for trials of 3- to 6-months duration. For global ratings, trials of 3 months duration with doses of 24-32mg/d (Odds Ratio (OR) 2.3; 95%CI 1.3 - 3.9) and 36mg/d (OR 3.4; 95%CI 1.2 - 9.5) were statistically significant in favour of treatment. For trials of 6 months duration (5-months to 29 weeks), only doses of 8mg/d failed to be associated with statistically significant benefit (16mg: OR 2.25; 95% CI 1.6 - 3.3; 24mg: OR 2.0; 95%CI 1.5 -2.5; 32mg: OR 1.9; 95%CI 1.4 - 2.5). For cognitive function over 6 months duration: at 16mg/d, improvements measured -3.3 points (k=1; 95%CI -4.4 - -2.1) on weighted mean difference on the ADAS-Cog scale; -3.5 points at 24mg/d (k=3; 95%CI -4.3 - -2.8), and -4.0 points at 32mg/d (k=2; 95%CI -5.0 - -3.0). The two 3-month trials with ADAS-Cog data also showed statistically significant improvement. Both observed cases (WMD 3.8; 95%CI 0.3 - 7.3) and intention-to-treat analyses using the Disability Assessment of Dementia scale gave statistically significant results in favour of treatment for daily doses of 32mg for 6 months duration (as did the single 3-month trial of 24-32mg/d treatment that used this scale). The small number of trials available for analysis, however, limited the power of subgroup analyses to detect differences. Galantamine consistently failed to show statistically significant treatment effects at doses of 8mg/day. Galantamine's adverse effects appear similar to those of other cholinesterase inhibitors, in that it tends to produce gastrointestinal symptoms acutely and with dosage increases. Overall, participants treated with galantamine at all doses for 3 months were more likely to discontinue that were those given placebo. Participants treated with galantamine at doses of 24-32 mg/d for 6 months were more likely to discontinue in most trials than were those treated with lower doses or placebo, with 32mg/d being associated with significantly higher withdrawal rates than was 24mg/d. However, in the one trial with a slower rate of titration the discontinuation rate was not significantly greater than placebo for the 16 mg/day dose. Patients in these trials were similar to those seen in earlier anti dementia AD trials, and consisted predominantly of mildly to moderately impaired outpatients. Galantamine's effects on more severely impaired people has not yet been assessed. Never the less, this review shows consistent positive effects for galantamine for trials of 3 months, 5 months and 6 months duration. In addition, although there was not a statistically significant dose-response effect, benefits associated with doses above 8mg/d were, for the most part, consistently statistically significant. There is therefore evidence for efficacy of galantamine on global ratings, cognitive tests, assessments of ADLs and behaviour. This magnitude for the cognitive effect is similar to that associated with other cholinesterase inhibitors including donepezil, rivastigmine, and tacrine. Galantamine's safety profile is similar to that of other cholinesterase inhibitors with regard to cholinergically mediated gastrointestinal symptoms. No information is available on adverse events that occurred less than 5% of the time. It appears that doses of 16 mg/d were best tolerated in the single trial where medication was titrated over 4-week periods, and because this dose showed statistically indistinguishable efficacy with higher doses, it is probably preferable initially. Longer-term use of galantamine has not been assessed in a controlled fashion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girigesh, Y; Kumar, L; Raman, K
Purpose: Aim of this study is to determine the dosimetric influence of Filtered and Flatting Filter Free Photon Beam of 10 MV energy on RA planning for Ca. Cervix. Methods: CT data sets of eleven patients reported with carcinoma cervix were used for RA planning for 10MV -FFB and 10MV-FFFB. RA plans were generated using two full arcs.All RA plans were generated to deliver a dose of 50.4Gy in 28 fractions for PTV and ALARA for OAR’s. All plans were analysed for PTV Coverage, conformity Index, homogeneity index, dose to OAR’s, integral dose to normal tissue and total monitor unitsmore » were studied. Results: DVH was used to evaluate RA plans for both 10MV-FFB and 10MV-FFFB photon beam. Planning results show a comparable PTV coverage for both energies. Results shows volume of PTV receiving prescription dose were 95.10+ 0.09% and 95.09 +0.11%, and volume of PTV receiving a dose of 107% is 0.45+0.96% and 5.25+8.9%, homogeneity index (HI) were 1.051+0.007 and 1.066+0.008, Conformity Index(CI) were 1.003+0.019 and 1.012+0.013, Mean Integral dose were 2.65+0.34 and 2.60+0.33(*10−5Gy.cm3) for 10MV-FFB and 10MV-FFFB respectively. 10MV-FB shows statistically significant (p<0.05) improvement in mean doses to bladder, rectum, bowel and mean total number of MU’s and also shows remarkable decrease in mean total no. of MU’s by 43.7% in comparison to 10MV-FFFB. There is statistically significant (p<0.05) difference found in CI and HI for 10MV-FB in comparison to 10MV -FFF beam. 10MV-FFFB shows statistically significant (p<0.05) for mean NTID and delivers 1.65 % less NTID in comparison to 10 MV- FB. Conclusion: 10MV-FB is superior to 10MV-FFFB for rapid arc planning in case of Cervix carcinomas, it offers better target coverage and OAR’s sparing, comparable mean Integral dose to normal tissues and 10 MV- FB also produced highly conformal and homogeneous dose distribution in comparison to 10MV-FFFB.« less
Sachdev, Sean; Refaat, Tamer; Bacchus, Ian D; Sathiaseelan, Vythialinga; Mittal, Bharat B
2017-08-01
Radiation-induced hypothyroidism affects a significant number of patients with head-and-neck squamous cell cancer (HNSCC). We examined detailed dosimetric and clinical parameters to better determine the risk of hypothyroidism in euthyroid HNSCC patients treated with intensity-modulated radiation therapy (IMRT). From 2006 to 2010, 75 clinically euthyroid patients with HNSCC were treated with sequential IMRT. The cohort included 59 men and 16 females with a median age of 55 years (range, 30 to 89 y) who were treated to a median dose of 70 Gy (range, 60 to 75 Gy) with concurrent chemotherapy in nearly all (95%) cases. Detailed thyroid dosimetric parameters including maximum dose, mean dose, and other parameters (eg, V50-percent volume receiving at least 50 Gy) were obtained. Freedom from hypothyroidism was evaluated using the Kaplan-Meier method. Univariate and multivariate analyses were conducted using Cox regression. After a median follow-up period of 50 months, 25 patients (33%) became hypothyroid. On univariate analysis, thyroid V50 was highly correlated with developing hypothyroidism (P=0.035). Other dosimetric paramaters including mean thyroid dose (P=0.11) and maximum thyroid dose (P=0.39) did not reach statistical significance. On multivariate analysis incorporating patient, tumor, and treatment variables, V50 remained highly statistically significant (P=0.037). Regardless of other factors, for V50>60%, the odds ratio of developing hypothyroidism was 6.76 (P=0.002). In HNSCC patients treated with IMRT, thyroid V50 highly predicts the risk of developing hypothyroidism. V50>60% puts patients at a significantly higher risk of becoming hypothyroid. This can be a useful dose constraint to consider during treatment planning.
Sci-Thur PM - Colourful Interactions: Highlights 08: ARC TBI using Single-Step Optimized VMAT Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, Alana; Gordon, Deborah; Moore, Roseanne
Purpose: This work outlines a new TBI delivery technique to replace a lateral POP full bolus technique. The new technique is done with VMAT arc delivery, without bolus, treating the patient prone and supine. The benefits of the arc technique include: increased patient experience and safety, better dose conformity, better organ at risk sparing, decreased therapist time and reduction of therapist injuries. Methods: In this work we build on a technique developed by Jahnke et al. We use standard arc fields with gantry speeds corrected for varying distance to the patient followed by a single step VMAT optimization on amore » patient CT to increase dose inhomogeneity and to reduce dose to the lungs (vs. blocks). To compare the arc TBI technique to our full bolus technique, we produced plans on patient CTs for both techniques and evaluated several dosimetric parameters using an ANOVA test. Results and Conclusions: The arc technique is able reduce both the hot areas to the body (D2% reduced from 122.2% to 111.8% p<0.01) and the lungs (mean lung dose reduced from 107.5% to 99.1%, p<0.01), both statistically significant, while maintaining coverage (D98% = 97.8% vs. 94.6%, p=0.313, not statistically significant). We developed a more patient and therapist-friendly TBI treatment technique that utilizes single-step optimized VMAT plans. It was found that this technique was dosimetrically equivalent to our previous lateral technique in terms of coverage and statistically superior in terms of reduced lung dose.« less
Ichikawa, Yasutaka; Kitagawa, Kakuya; Nagasawa, Naoki; Murashima, Shuichi; Sakuma, Hajime
2013-08-09
The recently developed model-based iterative reconstruction (MBIR) enables significant reduction of image noise and artifacts, compared with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP). The purpose of this study was to evaluate lesion detectability of low-dose chest computed tomography (CT) with MBIR in comparison with ASIR and FBP. Chest CT was acquired with 64-slice CT (Discovery CT750HD) with standard-dose (5.7 ± 2.3 mSv) and low-dose (1.6 ± 0.8 mSv) conditions in 55 patients (aged 72 ± 7 years) who were suspected of lung disease on chest radiograms. Low-dose CT images were reconstructed with MBIR, ASIR 50% and FBP, and standard-dose CT images were reconstructed with FBP, using a reconstructed slice thickness of 0.625 mm. Two observers evaluated the image quality of abnormal lung and mediastinal structures on a 5-point scale (Score 5 = excellent and score 1 = non-diagnostic). The objective image noise was also measured as the standard deviation of CT intensity in the descending aorta. The image quality score of enlarged mediastinal lymph nodes on low-dose MBIR CT (4.7 ± 0.5) was significantly improved in comparison with low-dose FBP and ASIR CT (3.0 ± 0.5, p = 0.004; 4.0 ± 0.5, p = 0.02, respectively), and was nearly identical to the score of standard-dose FBP image (4.8 ± 0.4, p = 0.66). Concerning decreased lung attenuation (bulla, emphysema, or cyst), the image quality score on low-dose MBIR CT (4.9 ± 0.2) was slightly better compared to low-dose FBP and ASIR CT (4.5 ± 0.6, p = 0.01; 4.6 ± 0.5, p = 0.01, respectively). There were no significant differences in image quality scores of visualization of consolidation or mass, ground-glass attenuation, or reticular opacity among low- and standard-dose CT series. Image noise with low-dose MBIR CT (11.6 ± 1.0 Hounsfield units (HU)) were significantly lower than with low-dose ASIR (21.1 ± 2.6 HU, p < 0.0005), low-dose FBP CT (30.9 ± 3.9 HU, p < 0.0005), and standard-dose FBP CT (16.6 ± 2.3 HU, p < 0.0005). MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT without compromising image quality. With radiation dose reduction of >70%, MBIR can provide equivalent lesion detectability of standard-dose FBP CT.
Effect of single dose of omeprazole on the gastrointestinal peptide response to food.
Allen, J M; Adrian, T E; Webster, J; Howe, A; Bloom, S R
1984-02-01
The gastrointestinal peptide response to food was assessed in 6 healthy subjects following oral administration of 40 mg omeprazole. There was a small but statistically significant increase in basal plasma gastrin six hours after the dose of omeprazole, but the post-prandial plasma gastrin was not significantly increased. There was no significant effect on basal or post-prandial levels of somatostatin, insulin, pancreatic glucagon, enteroglucagon, gastric inhibitory polypeptide, pancreatic polypeptide, motilin, neurotensin, cholecystokinin, secretin, vasoactive intestinal peptide and gastrin-releasing peptide or blood glucose concentration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Algan, Ozer, E-mail: oalgan@ouhsc.edu; Giem, Jared; Young, Julie
To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)–based or multiple isocenter (MI)–based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A totalmore » of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63 mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V{sub 100}. All of the other measured dosimetric parameters including the V{sub 95}, V{sub 99}, and D{sub 100} were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.« less
Algan, Ozer; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir
2015-01-01
To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)-based or multiple isocenter (MI)-based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V100. All of the other measured dosimetric parameters including the V95, V99, and D100 were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Schoedel, Kerri Alexandra; Chen, Nancy; Hilliard, Annie; White, Linda; Stott, Colin; Russo, Ethan; Wright, Stephen; Guy, Geoffrey; Romach, Myroslava K; Sellers, Edward M
2011-04-01
This study aimed to evaluate the abuse potential and cognitive effects of nabiximols (Sativex, GW Pharma Ltd. Salisbury, UK), an oromucosal spray primarily containing delta‐9‐tetrahydrocannabinol (THC) and cannabidiol (CBD). This was a single‐dose, randomized, double‐blind, crossover study comparing nabiximols (4, 8, and 16 consecutive sprays: 10.8, 21.6, and 43.2 mg THC, respectively) with dronabinol 20 and 40 mg (synthetic THC: Marinol, Solvay Pharmaceuticals, Brussels, Belgium) and matching placebos in 23 recreational cannabis users. Subjective and cognitive/psychomotor measures were administered over 24 h post‐dose. Dronabinol was significantly different from placebo on abuse potential measures, thereby confirming study validity. Nabiximols 10.8 mg was not significantly different from placebo on primary measures but was different on some secondary measures. Nabiximols 21.6 mg was significantly greater than placebo on some primary/secondary measures, whereas nabiximols 43.2 mg showed significant effects on most measures. Nabiximols 10.8 mg was significantly lower than dronabinol doses on most measures ( p < 0.05). Dronabinol 20 mg effects were numerically higher than nabiximols 21.6 mg but were statistically significant only for some measures. Dronabinol 40 mg and nabiximols 43.2 mg were generally not statistically different. Both dronabinol and nabiximols had significant abuse potential compared with placebo at higher doses. Nabiximols showed similar or slightly less abuse potential compared with dronabinol. Therefore, the abuse potential of nabiximols should be no higher than that of dronabinol.
Nasrollah, Jabbari; Mikaeil, Molazadeh; Omid, Esnaashari; Mojtaba, Seyed Siahi; Ahad, Zeinali
2014-01-01
The impact of intravenous (IV) contrast media (CM) on radiation dose calculations must be taken into account in treatment planning. The aim of this study is to evaluate the effect of an intravenous contrast media on dose calculations in three-dimensional conformal radiation therapy (3D-CRT) for lower esophageal and rectal cancers. Seventeen patients with lower esophageal tumors and 12 patients with rectal cancers were analyzed. At the outset, all patients were planned for 3D-CRT based on the computed tomography (CT) scans with IV contrast media. Subsequently, all the plans were copied and replaced on the scans without intravenous CM. The radiation doses calculated from the two sets of CTs were compared. The dose differences between the planning image set using intravenous contrast and the image set without contrast showed an average increase in Monitor Units (MUs) in the lower esophageal region that was 1.28 and 0.75% for 6 and 15 MV photon beams, respectively. There was no statistical significant difference in the rectal region between the two sets of scans in the 3D-CRT plans. The results showed that the dose differences between the plans for the CT scans with and without CM were small and clinically tolerable. However, the differences in the lower esophageal region were significant in the statistical analysis.
Nitrogen Dioxide Exposure and Airway Responsiveness in ...
Controlled human exposure studies evaluating the effect of inhaled NO2 on the inherent responsiveness of the airways to challenge by bronchoconstricting agents have had mixed results. In general, existing meta-analyses show statistically significant effects of NO2 on the airway responsiveness of individuals with asthma. However, no meta-analysis has provided a comprehensive assessment of clinical relevance of changes in airway responsiveness, the potential for methodological biases in the original papers, and the distribution of responses. This paper provides analyses showing that a statistically significant fraction, 70% of individuals with asthma exposed to NO2 at rest, experience increases in airway responsiveness following 30-minute exposures to NO2 in the range of 200 to 300 ppb and following 60-minute exposures to 100 ppb. The distribution of changes in airway responsiveness is log-normally distributed with a median change of 0.75 (provocative dose following NO2 divided by provocative dose following filtered air exposure) and geometric standard deviation of 1.88. About a quarter of the exposed individuals experience a clinically relevant reduction in their provocative dose due to NO2 relative to air exposure. The fraction experiencing an increase in responsiveness was statistically significant and robust to exclusion of individual studies. Results showed minimal change in airway responsiveness for individuals exposed to NO2 during exercise. A variety of fa
Geyer, Lucas L; Körner, Markus; Harrieder, Andreas; Mueck, Fabian G; Deak, Zsuzsanna; Wirth, Stefan; Linsenmaier, Ulrich
2016-01-01
Evaluation of potential dose savings by implementing adaptive statistical iterative reconstruction (ASiR) on a gemstone-based scintillator in a clinical 64-row whole-body CT (WBCT) protocol after multiple trauma. Dose reports of 152 WBCT scans were analysed for two 64-row multidetector CT scanners (Scanners A and B); the main scanning parameters were kept constant. ASiR and a gemstone-based scintillator were used in Scanner B, and the noise index was adjusted (head: 5.2 vs 6.0; thorax/abdomen: 29.0 vs 46.0). The scan length, CT dose index (CTDI) and dose-length product (DLP) were analysed. The estimated mean effective dose was calculated using normalized conversion factors. Student's t-test was used for statistics. Both the mean CTDI (mGy) (Scanner A: 53.8 ± 2.0, 10.3 ± 2.5, 14.4 ± 3.7; Scanner B: 48.7 ± 2.2, 7.1 ± 2.3, 9.1 ± 3.6; p < 0.001, respectively) and the mean DLP (mGy cm) (Scanner A: 1318.9 ± 167.8, 509.3 ± 134.7, 848.8 ± 254.0; Scanner B: 1190.6 ± 172.6, 354.6 ± 128.3, 561.0 ± 246.7; p < 0.001, respectively) for the head, thorax and abdomen were significantly reduced with Scanner B. There was no relevant difference in scan length. The total mean effective dose (mSv) was significantly decreased with Scanner B (24.4 ± 6.0, 17.2 ± 5.8; p < 0.001). The implementation of ASiR and a gemstone-based scintillator allows for significant dose savings in a clinical WBCT protocol. Recent technical developments can significantly reduce radiation dose of WBCT in multiple trauma. Dose reductions of 10-34% can be achieved.
Zgheib, Nathalie K; Akika, Reem; Mahfouz, Rami; Aridi, Carol Al; Ghanem, Khaled M; Saab, Raya; Abboud, Miguel R; Tarek, Nidale; El Solh, Hassan; Muwakkit, Samar A
2017-01-01
Interindividual variability in thiopurine-related toxicity could not be completely explained by thiopurine S-methyltransferase (TPMT) polymorphisms, as a number of patients who are homozygous wild type or normal for TPMT still develop toxicity that necessitates 6-mercaptopurine (MP) dose reduction or protocol interruption. Recently, few studies reported on an inherited nucleoside diphosphate-linked moiety X motif 15 (NUDT15) c.415C>T low-function variant that is associated with decreased thiopurine metabolism and leukopenia in childhood acute lymphoblastic leukemia (ALL) and other diseases. The aim of this study is to measure the frequency of TPMT and NUDT15 polymorphisms and assess whether they are predictors of MP intolerance in children treated for ALL. One hundred thirty-seven patients with ALL of whom 121 were Lebanese were evaluated. MP dose intensity was calculated as the ratio of the tolerated MP dose to planned dose during continuation phase to maintain an absolute neutrophil count (ANC) dose above 300 per μl. One patient was NUDT15 heterozygous TC and tolerated only 33.33% of the planned MP dose, which was statistically significantly different from the median-tolerated MP dose intensity of the rest of the cohort (76.00%). Three patients had the TPMT*3A haplotype and tolerated 40.00-66.66% of the planned MP dose, which was also statistically significantly different from the rest of the cohort. This is the first report on the association of TPMT and NUDT15 polymorphisms with MP dose intolerance in Arab patients with ALL. Genotyping for additional polymorphisms may be warranted for potential gene/allele-dose effect. © 2016 Wiley Periodicals, Inc.
Caplice, Noel M; DeVoe, Mary C; Choi, Janet; Dahly, Darren; Murphy, Theodore; Spitzer, Ernest; Van Geuns, Robert; Maher, Michael M; Tuite, David; Kerins, David M; Ali, Mohammed T; Kalyar, Imtiaz; Fahy, Eoin F; Khider, Wisam; Kelly, Peter; Kearney, Peter P; Curtin, Ronan J; O'Shea, Conor; Vaughan, Carl J; Eustace, Joseph A; McFadden, Eugene P
2018-06-01
Residual and significant postinfarction left ventricular (LV) dysfunction, despite technically successful percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction (STEMI), remains an important clinical issue. In preclinical models, low-dose insulin-like growth factor 1 (IGF1) has potent cytoprotective and positive cardiac remodeling effects. We studied the safety and efficacy of immediate post-PCI low-dose intracoronary IGF1 infusion in STEMI patients. Using a double-blind, placebo-controlled, multidose study design, we randomized 47 STEMI patients with significantly reduced (≤40%) LV ejection fraction (LVEF) after successful PCI to single intracoronary infusion of placebo (n = 15), 1.5 ng IGF1 (n = 16), or 15 ng IGF1 (n = 16). All received optimal medical therapy. Safety end points were freedom from hypoglycemia, hypotension, or significant arrhythmias within 1 hour of therapy. The primary efficacy end point was LVEF, and secondary end points were LV volumes, mass, stroke volume, and infarct size at 2-month follow-up, all assessed by magnetic resonance imaging. Treatment effects were estimated by analysis of covariance adjusted for baseline (24 hours) outcome. No significant differences in safety end points occurred between treatment groups out to 30 days (χ 2 test, P value = .77). There were no statistically significant differences in baseline (24 hours post STEMI) clinical characteristics or LVEF among groups. LVEF at 2 months, compared to baseline, increased in all groups, with no statistically significant differences related to treatment assignment. However, compared with placebo or 1.5 ng IGF1, treatment with 15 ng IGF1 was associated with a significant improvement in indexed LV end-diastolic volume (P = .018), LV mass (P = .004), and stroke volume (P = .016). Late gadolinium enhancement (±SD) at 2 months was lower in 15 ng IGF1 (34.5 ± 29.6 g) compared to placebo (49.1 ± 19.3 g) or 1.5 ng IGF1 (47.4 ± 22.4 g) treated patients, although the result was not statistically significant (P = .095). In this pilot trial, low-dose IGF1, given after optimal mechanical reperfusion in STEMI, is safe but does not improve LVEF. However, there is a signal for a dose-dependent benefit on post-MI remodeling that may warrant further study. Copyright © 2018. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Ang, W. C.; Hashim, S.; Karim, M. K. A.; Bahruddin, N. A.; Salehhon, N.; Musa, Y.
2017-05-01
The widespread use of computed tomography (CT) has increased the medical radiation exposure and cancer risk. We aimed to evaluate the impact of AIDR 3D in CT abdomen-pelvic examinations based on image quality and radiation dose in low dose (LD) setting compared to standard dose (STD) with filtered back projection (FBP) reconstruction. We retrospectively reviewed the images of 40 patients who underwent CT abdomen-pelvic using a 80 slice CT scanner. Group 1 patients (n=20, mean age 41 ± 17 years) were performed at LD with AIDR 3D reconstruction and Group 2 patients (n=20, mean age 52 ± 21 years) were scanned with STD using FBP reconstruction. Objective image noise was assessed by region of interest (ROI) measurements in the liver and aorta as standard deviation (SD) of the attenuation value (Hounsfield Unit, HU) while subjective image quality was evaluated by two radiologists. Statistical analysis was used to compare the scan length, CT dose index volume (CTDIvol) and image quality of both patient groups. Although both groups have similar mean scan length, the CTDIvol significantly decreased by 38% in LD CT compared to STD CT (p<0.05). Objective and subjective image quality were statistically improved with AIDR 3D (p<0.05). In conclusion, AIDR 3D enables significant dose reduction of 38% with superior image quality in LD CT abdomen-pelvis.
Mohammed, Riazuddin; Johnson, Karl; Bache, Ed
2010-07-01
Multiple radiographic images may be necessary during the standard procedure of in-situ pinning of slipped capital femoral epiphysis (SCFE) hips. This procedure can be performed with the patient positioned on a fracture table or a radiolucent table. Our study aims to look at any differences in the amount and duration of radiation exposure for in-situ pinning of SCFE performed using a traction table or a radiolucent table. Sixteen hips in thirteen patients who were pinned on radiolucent table were compared for the cumulative radiation exposure to 35 hips pinned on a fracture table in 33 patients during the same time period. Cumulative radiation dose was measured as dose area product in Gray centimeter2 and the duration of exposure was measured in minutes. Appropriate statistical tests were used to test the significance of any differences. Mean cumulative radiation dose for SCFE pinned on radiolucent table was statistically less than for those pinned on fracture table (P<0.05). The mean duration of radiation exposure on either table was not significantly different. Lateral projections may increase the radiation doses compared with anteroposterior projections because of the higher exposure parameters needed for side imaging. Our results showing decreased exposure doses on the radiolucent table are probably because of the ease of a frog leg lateral positioning obtained and thereby the ease of lateral imaging. In-situ pinning of SCFE hips on a radiolucent table has an additional advantage that the radiation dose during the procedure is significantly less than that of the procedure that is performed on a fracture table.
Effects of chromium picolinate on oxidative damage in primary piglet hepatocytes.
Tan, Gao-Yi; Bi, Jin-Ming; Zhang, Min-Hong; Feng, Jing-Hai; Xie, Peng; Zheng, Shan-Shan
2008-12-01
Chromium picolinate is a popular nutritional supplement whose safety has been questioned because of the potential risk of oxidative DNA damage. To investigate this possibility, a dose-dependent study was performed in piglet hepatocyte cultures in which low (8 microM), medium (200 microM), and high (400 microM) doses of chromium picolinate were tested and compared to untreated controls. After 48 h incubation, there were no significant differences in the levels of intracellular reactive oxygen species, medium lactate dehydrogenase activity, and comet indicators between the three experimental groups and controls (p > 0.05). In the 8 microM-treated group, the intracellular malondialdehyde content was significantly decreased relative to controls (p < 0.05). All of the studied parameters showed a dose-dependent increase that was statistically significant between the low and high doses (p < 0.05). These results suggest that: (1) chromium picolinate may affect the oxidative status of piglet hepatocytes; (2) the appropriate dose (approximately physiological concentration) of chromium picolinate can inhibit lipid peroxidation, and (3) high doses of chromium picolinate have no significant effects on oxidative damage in piglet hepatocytes, but the existing evidence also imply that exposure to a higher dose appears to be unwarranted.
Gyanani, Hitesh; Chhabra, Naveen; Parmar, Ghanshyam R.
2016-01-01
Aim: Study aimed to evaluate the efficacy of two different pretreatment single oral doses of betamethasone on the incidence of inter-appointment flare up and postoperative discomfort. Materials and Methods: Fifty-four patients aged 18–59 years requiring endodontic treatment were selected and randomly assigned to three groups; single pretreatment oral dose of placebo or betamethasone in two different oral doses of 0.5 mg and 1 mg, respectively. Endodontic therapy was completed in two visits using triple antibiotic paste as intracanal medicament. Patients were given a questionnaire to record their pain at 1, 2, 3, and 7 days after treatment. In the second visit, obturation was done, and the patients were again instructed to record their pain scores after treatment and discharged. The verbal rating scale was used for recording the pain scores. Statistical analysis was done using ANOVA and the Friedman test. Results: 0.5 mg betamethasone group showed least mean pain scores among all experimental groups; however, there was no statistically significant difference between any of the groups (P > 0.05). Conclusion: Pretreatment single oral dose of betamethasone is an effective in managing endodontic flare-ups; however, the results were statistically insignificant. PMID:27994320
Oral 5-aminosalicylic acid for maintenance of remission in ulcerative colitis.
Wang, Yongjun; Parker, Claire E; Feagan, Brian G; MacDonald, John K
2016-05-09
Oral 5-aminosalicylic (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs were more effective than placebo but had a statistically significant therapeutic inferiority relative to SASP. This updated review includes more recent studies and evaluates the effectiveness, dose-responsiveness, and safety of 5-ASA preparations used for maintenance of remission in quiescent ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for maintenance of remission in quiescent ulcerative colitis. A secondary objective was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A literature search for relevant studies (inception to 9 July 2015) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled trials with a minimum treatment duration of six months. Studies of oral 5-ASA therapy for treatment of patients with quiescent ulcerative colitis compared with placebo, SASP or other 5-ASA formulations were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA and 5-ASA dose ranging studies were also considered for inclusion. The primary outcome was the failure to maintain clinical or endoscopic remission. Secondary outcomes included adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA formulation, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol and Salofalk). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the risk ratio (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention-to-treat basis. Forty-one studies (8928 patients) were included. The majority of included studies were rated as low risk of bias. Ten studies were rated at high risk of bias. Seven of these studies were single-blind and three studies were open-label. However, two open-label studies and four of the single-blind studies utilized investigator performed endoscopy as an endpoint, which may protect against bias. 5-ASA was significantly superior to placebo for maintenance of clinical or endoscopic remission. Forty-one per cent of 5-ASA patients relapsed compared to 58% of placebo patients (7 studies, 1298 patients; RR 0.69, 95% CI 0.62 to 0.77). There was a trend towards greater efficacy with higher doses of 5-ASA with a statistically significant benefit for the 1 to 1.9 g/day (RR 0.65; 95% CI 0.56 to 0.76) and the > 2 g/day subgroups (RR 0.73, 95% CI 0.60 to 0.89). SASP was significantly superior to 5-ASA for maintenance of remission. Forty-eight per cent of 5-ASA patients relapsed compared to 43% of SASP patients (12 studies, 1655 patients; RR 1.14, 95% CI 1.03 to 1.27). A GRADE analysis indicated that the overall quality of the evidence for the primary outcome for the placebo and SASP-controlled studies was high. No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Twenty-nine per cent of once daily patients relapsed over 12 months compared to 31% of conventionally dosed patients (8 studies, 3127 patients; RR 0.91, 95% CI 0.82 to 1.01). Eleven per cent of patients in the once daily group failed to adhere to their medication regimen compared to 9% of patients in the conventional dosing group (6 studies, 1462 patients; RR 1.22, 95% CI 0.91 to 1.64). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Forty-four per cent of patients in the 5-ASA group relapsed compared to 41% of patients in the 5-ASA comparator group (6 studies, 707 patients; RR 1.08, 95% CI 0.91 to 1.28). A pooled analysis of two studies showed no statistically significant difference in efficacy between Balsalazide 6 g and 3 g/day. Twenty-three per cent of patients in the 6 g/day group relapsed compared to 33% of patients in the 3 g/day group (216 patients; RR 0.76; 95% CI 0.45 to 2.79). One study found Balsalazide 4 g to be superior to 2 g/day. Thirty-seven per cent of patients in the 4 g/day Balsalazide group relapsed compared to 55% of patients in the 2 g/day group (133 patients; RR 0.66; 95% CI 0.45 to 0.97). One study found a statistically significant difference between Salofalk granules 3 g and 1.5 g/day. Twenty-five per cent of patients in the Salofalk 3 g/day group relapsed compared to 39% of patients in the 1.5 g/day group (429 patients; RR 0.65; 95% CI 0.49 to 0.86). Common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache, dyspepsia, and nasopharyngitis. There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, 5-ASA and SASP, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulations and 5-ASA dose ranging studies. The trials that compared 5-ASA and SASP may have been biased in favour of SASP because most trials enrolled patients known to be tolerant to SASP which may have minimized SASP-related adverse events. 5-ASA was superior to placebo for maintenance therapy in ulcerative colitis. However, 5-ASA had a statistically significant therapeutic inferiority relative to SASP. Oral 5-ASA administered once daily is as effective and safe as conventional dosing for maintenance of remission in quiescent ulcerative colitis. There does not appear to be any difference in efficacy or safety between the various formulations of 5-ASA. Patients with extensive ulcerative colitis or with frequent relapses may benefit from a higher dose of maintenance therapy. High dose therapy appears to be as safe as low dose and is not associated with a higher incidence of adverse events.
DICOM organ dose does not accurately represent calculated dose in mammography
NASA Astrophysics Data System (ADS)
Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.
2016-03-01
This study aims to analyze the agreement between the mean glandular dose estimated by the mammography unit (organ dose) and mean glandular dose calculated using Dance et al published method (calculated dose). Anonymised digital mammograms from 50 BreastScreen NSW centers were downloaded and exposure information required for the calculation of dose was extracted from the DICOM header along with the organ dose estimated by the system. Data from quality assurance annual tests for the included centers were collected and used to calculate the mean glandular dose for each mammogram. Bland-Altman analysis and a two-tailed paired t-test were used to study the agreement between calculated and organ dose and the significance of any differences. A total of 27,869 dose points from 40 centers were included in the study, mean calculated dose and mean organ dose (+/- standard deviation) were 1.47 (+/-0.66) and 1.38 (+/-0.56) mGy respectively. A statistically significant 0.09 mGy bias (t = 69.25; p<0.0001) with 95% limits of agreement between calculated and organ doses ranging from -0.34 and 0.52 were shown by Bland-Altman analysis, which indicates a small yet highly significant difference between the two means. The use of organ dose for dose audits is done at the risk of over or underestimating the calculated dose, hence, further work is needed to identify the causal agents for differences between organ and calculated doses and to generate a correction factor for organ dose.
Reducing statistical uncertainties in simulated organ doses of phantoms immersed in water
Hiller, Mauritius M.; Veinot, Kenneth G.; Easterly, Clay E.; ...
2016-08-13
In this study, methods are addressed to reduce the computational time to compute organ-dose rate coefficients using Monte Carlo techniques. Several variance reduction techniques are compared including the reciprocity method, importance sampling, weight windows and the use of the ADVANTG software package. For low-energy photons, the runtime was reduced by a factor of 10 5 when using the reciprocity method for kerma computation for immersion of a phantom in contaminated water. This is particularly significant since impractically long simulation times are required to achieve reasonable statistical uncertainties in organ dose for low-energy photons in this source medium and geometry. Althoughmore » the MCNP Monte Carlo code is used in this paper, the reciprocity technique can be used equally well with other Monte Carlo codes.« less
Liao, Yen-Nung; Liu, Ching-Shen; Tsai, Tong-Rong; Hung, Yu-Chiang; Chang, Shun-Jen; Lin, Hong-Long; Chen, Ying-Chou; Lai, Han-Ming; Yu, Shan-Fu; Chen, Chung-Jen
2011-07-01
Systemic lupus erythematosus (SLE) is a chronic systemic autoimmune disease. Prolonged complete remission is rare. Most patients with SLE need long-term treatment with glucocorticoid and immunomodulators. However, side effects because of the above medications are common. We evaluated the effect of adding-on Dan-Chi-Liu-Wei combination (DCLWC) on SLE patients with conventional therapy in tapering steroid and preventing disease flare-up. This was a double-blind and randomized controlled trial. Sixty-six SLE patients were recruited into this study and 53 patients who fulfilled the 1997 revised criteria for the classification of SLE with an SLE disease activity index (SLEDAI) score of 2-12 and a steroid (measured with prednisolone) daily dose of less than 20mg/d were enrolled. The patients were randomized into either an experimental or control group. We checked the urine analysis, hemogram, liver function, renal function, C3, C4, erythrocyte sedimentation rate, and anti-dsDNA, evaluated the SLEDAI score, and recorded the steroid dose at 0 months, 3 months, and 6 months, respectively. After 6 months of study, the C4 and blood urea nitrogen level revealed a statistically significant difference in either group. There was a tendency toward a decreased SLEDAI score in the experimental group (p=0.083) but not in the control group (p=0.867). The steroid dose was not statistically significant in either group. Renal function and liver function revealed no statistically significant statistics changes in either group. Adding-on DCLWC to conventional therapy for the treatment of SLE was safe and might have a borderline effect in decreasing disease activity, but it was not possible to taper the dosage of steroid after 6 months of clinical trial. Therefore, a long-term follow-up and a large-scale study are necessary to confirm the effect of DCLWC. Copyright © 2011 Elsevier Taiwan LLC. All rights reserved.
Role of belly board device in the age of intensity modulated radiotherapy for pelvic irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Estabrook, Neil C.; Bartlett, Gregory K.; Compton, Julia J.
Small bowel dose often represents a limiting factor for radiation treatment of pelvic malignancies. To reduce small bowel toxicity, a belly board device (BBD) with a prone position is often recommended. Intensity modulated radiotherapy (IMRT) could reduce dose to small bowel based on the desired dose-volume constraints. We investigated the efficacy of BBD in conjunction with IMRT. A total of 11 consecutive patients with the diagnosis of rectal cancer, who were candidates for definitive therapy, were selected. Patients were immobilized with BBD in prone position for simulation and treatment. Supine position computed tomography (CT) data were either acquired at themore » same time or during a diagnostic scan, and if existed was used. Target volumes (TV) as well as organs at risk (OAR) were delineated in both studies. Three-dimensional conformal treatment (3DCRT) and IMRT plans were made for both scans. Thus for each patient, 4 plans were generated. Statistical analysis was conducted for maximum, minimum, and mean dose to each structure. When comparing the normalized mean Gross TV dose for the different plans, there was no statistical difference found between the planning types. There was a significant difference in small bowel sparing when using prone position on BBD comparing 3DCRT and IMRT plans, favoring IMRT with a 29.6% reduction in dose (p = 0.007). There was also a statistically significant difference in small bowel sparing when comparing supine position IMRT to prone-BBD IMRT favoring prone-BBD IMRT with a reduction of 30.3% (p = 0.002). For rectal cancer when small bowel could be a limiting factor, prone position using BBD along with IMRT provides the best sparing. We conclude that whenever a dose escalation in rectal cancer is desired where small bowel could be limiting factor, IMRT in conjunction with BBD should be selected.« less
Zablotska, Lydia B.; Lane, Rachel S.D.; Frost, Stanley E.; Thompson, Patsy A.
2014-01-01
Uranium workers are chronically exposed to low levels of radon decay products (RDP) and gamma (γ) radiation. Risks of leukemia from acute and high doses of γ-radiation are well-characterized, but risks from lower doses and dose-rates and from RDP exposures are controversial. Few studies have evaluated risks of other hematologic cancers in uranium workers. The purpose of this study was to analyze radiation-related risks of hematologic cancers in the cohort of Eldorado uranium miners and processors first employed in 1932–1980 in relation to cumulative RDP exposures and γ-ray doses. The average cumulative RDP exposure was 100.2 working level months and the average cumulative whole-body γ-radiation dose was 52.2 millisievert. We identified 101 deaths and 160 cases of hematologic cancers in the cohort. Overall, male workers had lower mortality and cancer incidence rates for all outcomes compared with the general Canadian male population, a likely healthy worker effect. No statistically significant association between RDP exposure or γ-ray doses, or a combination of both, and mortality or incidence of any hematologic cancer was found. We observed consistent but non-statistically significant increases in risks of chronic lymphocytic leukemia (CLL) and Hodgkin lymphoma (HL) incidence and non-Hodgkin lymphoma (NHL) mortality with increasing γ-ray doses. These findings are consistent with recent studies of increased risks of CLL and NHL incidence after γ-radiation exposure. Further research is necessary to understand risks of other hematologic cancers from low-dose exposures to γ-radiation. PMID:24583244
Uliana, Gustavo Nadal; Tambara, Elizabeth Milla; Baretta, Giorgio Alfredo Pedroso
2015-01-01
The introduction of propofol (2,6-diisopropylphenol) as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE) diagnostic tests. One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student's t-test was used to compare the mean of age, weight, height (cm), and dose (mg/kg) variables between groups. The χ(2) test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was α<0.05. There was significant statistical difference between the study groups and the control group regarding the parameters of propofol injection pain and total dose of propofol (mg/kg) used. However, there were no statistical differences between the two study groups for these parameters. We conclude that the use of remifentanil at doses of 0.2mg/kg and 0.3mg/kg was effective for reducing both the propofol injection pain and the total dose of propofol used. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diez, Patricia; Vogelius, Ivan S.; Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792
2010-07-15
Purpose: A new method is presented for synthesizing dose-response data for biochemical control of prostate cancer according to study design (randomized vs. nonrandomized) and risk group (low vs. intermediate-high). Methods and Materials: Nine published prostate cancer dose escalation studies including 6,539 patients were identified in the MEDLINE and CINAHL databases and reviewed to assess the relationship between dose and biochemical control. A novel method of analysis is presented in which the normalized dose-response gradient, {gamma}{sub 50}, is estimated for each study and subsequently synthesized across studies. Our method does not assume that biochemical control rates are directly comparable between studies.more » Results: Nonrandomized studies produced a statistically significantly higher {gamma}{sub 50} than randomized studies for intermediate- to high-risk patients ({gamma}{sub 50} = 1.63 vs. {gamma}{sub 50} = 0.93, p = 0.03) and a borderline significantly higher ({gamma}{sub 50} = 1.78 vs. {gamma}{sub 50} = 0.56, p = 0.08) for low-risk patients. No statistically significant difference in {gamma}{sub 50} was found between low- and intermediate- to high-risk patients (p = 0.31). From the pooled data of low and intermediate- to high-risk patients in randomized trials, we obtain the overall best estimate of {gamma}{sub 50} = 0.84 with 95% confidence interval 0.54-1.15. Conclusions: Nonrandomized studies overestimate the steepness of the dose-response curve as compared with randomized trials. This is probably the result of stage migration, improved treatment techniques, and a shorter follow-up in higher dose patients that were typically entered more recently. This overestimation leads to inflated expectations regarding the benefit from dose-escalation and could lead to underpowered clinical trials. There is no evidence of a steeper dose response for intermediate- to high-risk compared with low-risk patients.« less
Umeh, Chizoba C; Pérez, Adriana; Augustine, Erika F; Dhall, Rohit; Dewey, Richard B; Mari, Zoltan; Simon, David K; Wills, Anne-Marie A; Christine, Chadwick W; Schneider, Jay S; Suchowersky, Oksana
2014-01-01
Sex differences in Parkinson disease clinical features have been reported, but few studies have examined sex influences on use of dopaminergic medication in early Parkinson disease. The objective of this study was to test if there are differences in the type of dopaminergic medication used and levodopa equivalent daily dose between men and women with early Parkinson disease enrolled in a large multicenter study of Creatine as a potential disease modifying therapy - the National Institute of Neurological Disorders and Stroke Exploratory Trials in Parkinson Disease Long-Term Study-1. Baseline data of 1,741 participants from 45 participating sites were analyzed. Participants from the United States and Canada were enrolled within five years of Parkinson Disease diagnosis. Two outcome variables were studied: type of dopaminergic medication used and levodopa equivalent daily dose at baseline in the Long-Term Study-1. Chi-square statistic and linear regression models were used for statistical analysis. There were no statistically significant differences in the frequency of use of different types of dopaminergic medications at baseline between men and women with Parkinson Disease. A small but statistically significant difference was observed in the median unadjusted levodopa equivalent daily dose at baseline between women (300 mg) and men (325 mg), but this was not observed after controlling for disease duration (years since Parkinson disease diagnosis), disease severity (Unified Parkinson's Disease Rating Scale Motor and Activities of Daily Living Scores), and body weight. In this large multicenter study, we did not observe sex differences in the type and dose of dopaminergic medications used in early Parkinson Disease. Further research is needed to evaluate the influence of male or female sex on use of dopaminergic medication in mid- and late-stage Parkinson Disease.
Vogl, T J; Friebe, C E; Balzer, T; Mack, M G; Steiner, S; Schedel, H; Pegios, W; Lanksch, W; Banzer, D; Felix, R
1995-08-01
To assess the effectiveness and safety of normal and high doses of Gadobutrol versus a standard dose of Gadolinium DTPA in the MR evaluation of patients with brain metastases. In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spin-echo images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. The first in vivo results prove the excellent contrast capacity of the nonionic contrast agent Gadobutrol for the diagnosis of intracerebral metastases.
Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T
2016-01-01
Background Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. Purpose To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Material and Methods Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. Results There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. Conclusion There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality. PMID:27583169
Østerås, Bjørn Helge; Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T
2016-08-01
Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor's water phantom. There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between -3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and -7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality.
Tenant, Sean; Pang, Chun Lap; Dissanayake, Prageeth; Vardhanabhuti, Varut; Stuckey, Colin; Gutteridge, Catherine; Hyde, Christopher; Roobottom, Carl
2017-10-01
To evaluate the accuracy of reduced-dose CT scans reconstructed using a new generation of model-based iterative reconstruction (MBIR) in the imaging of urinary tract stone disease, compared with a standard-dose CT using 30% adaptive statistical iterative reconstruction. This single-institution prospective study recruited 125 patients presenting either with acute renal colic or for follow-up of known urinary tract stones. They underwent two immediately consecutive scans, one at standard dose settings and one at the lowest dose (highest noise index) the scanner would allow. The reduced-dose scans were reconstructed using both ASIR 30% and MBIR algorithms and reviewed independently by two radiologists. Objective and subjective image quality measures as well as diagnostic data were obtained. The reduced-dose MBIR scan was 100% concordant with the reference standard for the assessment of ureteric stones. It was extremely accurate at identifying calculi of 3 mm and above. The algorithm allowed a dose reduction of 58% without any loss of scan quality. A reduced-dose CT scan using MBIR is accurate in acute imaging for renal colic symptoms and for urolithiasis follow-up and allows a significant reduction in dose. • MBIR allows reduced CT dose with similar diagnostic accuracy • MBIR outperforms ASIR when used for the reconstruction of reduced-dose scans • MBIR can be used to accurately assess stones 3 mm and above.
Radiation Doses from the Norwegian Diet.
Komperød, Mari; Skuterud, Lavrans
2018-06-13
Ingestion doses between and within countries are expected to vary significantly due to differences in dietary habits and geographical variations in radionuclide concentrations. This paper presents the most comprehensive assessment to date of the effective radiation dose from the Norwegian diet, from natural as well as anthropogenic radionuclides. Ingestion doses to the Norwegian public are calculated using national dietary statistics and the most relevant radionuclide concentration data for the various food products. The age-weighted average effective dose received by the Norwegian population from the diet is estimated at 0.41 mSv y from naturally occurring radionuclides and 0.010 mSv y from anthropogenic radionuclides. This is approximately 50% higher than the estimated world average. Fish and shellfish is the food group that provides the largest dose contribution from the average Norwegian diet. Although the average dose from anthropogenic radionuclides today is low, the exposure may still be significant for certain critical groups-especially persons who consume large amounts of reindeer meat from the regions that received significant radioactive fallout after the Chernobyl accident. Furthermore, persons with high Rn concentrations in their drinking water are among those receiving the highest ingestion doses in Norway.
SU-E-T-72: A Retrospective Correlation Analysis On Dose-Volume Control Points and Treatment Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roy, A; Nohadani, O; Refaat, T
2015-06-15
Purpose: To quantify correlation between dose-volume control points and treatment outcomes. Specifically, two outcomes are analyzed: occurrence of radiation induced dysphagia and target complications. The results inform the treatment planning process when competing dose-volume criteria requires relaxations. Methods: 32 patients, treated with whole-field sequential intensity modulated radiation therapy during 2009–2010 period, are considered for this study. Acute dysphagia that is categorized into 3 grades is observed on all patients. 3 patients are observed in grade 1, 17 patients in grade 2, and 12 patients in grade 3. Ordinal logistic regression is employed to establish correlations between grades of dysphagia andmore » dose to cervico-thoracic esophagus. Particularly, minimum (Dmin), mean (Dmean), and maximum (Dmax) dose control points are analyzed. Additionally, target complication, which includes local-regional recurrence and/or distant metastasis, is observed on 4 patients. Binary logistic regression is used to quantify correlation between target complication and four dose control points. Namely, ICRU recommended dose control points, D2, D50, D95, and D98 are analyzed. Results: For correlation with dysphagia, Dmin on cervico-thoracic esophagus is statistically significant (p-value = 0.005). Additionally, Dmean on cervico-thoracic esophagus is also significant in association with dysphagia (p-value = 0.012). However, no correlation was observed between Dmax and dysphagia (p-value = 0.263). For target complications, D50 on the target is a statistically significant dose control point (p-value = 0.032). No correlations were observed between treatment complications and D2 (p-value = 0.866), D95 (p-value = 0.750), and D98 (p-value = 0.710) on the target. Conclusion: Significant correlations are observed between radiation induced dysphagia and Dmean (and Dmin) to cervico-thoracic esophagus. Additionally, correlation between target complications and median dose to target (D50) is observed. Quantification of these correlations can inform treatment planners when any competing objectives requires relaxation of target D50 or Dmean (or Dmin) to cervico-thoracic esophagus.« less
Kashcheev, V V; Chekin, S Yu; Karpenko, S V; Maksioutov, M A; Menyaylo, A N; Tumanov, K A; Kochergina, E V; Kashcheeva, P V; Gorsky, A I; Shchukina, N V; Lovachev, S S; Vlasov, O K; Ivanov, V K
2017-07-01
This paper continues a series of publications that analyze the impact of radiation on incidence of circulatory system diseases in the cohort of Russian recovery operation workers (liquidators) and presents the results of the analysis of cardiovascular disease (CVD) incidence. The studied cohort consists of 53,772 liquidators who arrived in the Chernobyl accident zone within the first year after the accident (26 April 1986 to 26 April 1987). The individual doses varied from 0.0001 Gy to 1.42 Gy, and the mean external whole body dose in the cohort was 0.161 Gy. A total of 27,456 cases of CVD were diagnosed during the follow-up period 1986-2012 as a result of annual health examinations. A Poisson regression model was applied to estimate radiation risks and other risk factors associated with CVD. The following factors were identified as risk factors for CVD: the dose, duration of the liquidators' work in the Chernobyl zone, and concomitant diseases (diabetes mellitus, hypertension, overweight, and alcohol dependence). The baseline incidence of CVD is statistically significantly (p < 0.001) associated with all studied concomitant diseases. The incidence of CVD has revealed a statistically significant dose response with the lack of a latent period and with the average ERR Gy = 0.47, 95% CI = 0.31, 0.63, p < 0.001. Radiation risks of CVD statistically significantly (p = 0.01) varied with the duration of liquidators' stay in the Chernobyl zone; for those who stayed in the Chernobyl zone less than 6 wk, ERR/Gy = 0.80, 95% CI = 0.53; 1.08, p < 0.001.
Fantinato, Francieli Fontana Sutile Tardetti; Vargas, Alexander; Carvalho, Sandra Maria Deotti; Domingues, Carla Magda Allan Santos; Barreto, Gisele; Fialho, Arieli Schiessl; Silva, Roselita Heinen da; Saad, Eduardo; Agredo, Ivonne Natalia Solarte
2018-03-12
The study aimed to describe cases and verify the frequency of anaphylaxis related to measles, mumps, and rubella (MMR) vaccine produced by manufacturer A and to assess associated risk factors. This was a case-control study (1:4) in Santa Catarina State, Brazil, from July 14, 2014, to January 12, 2015, in children from one year to less than five years of age, vaccinated with MMR and reported with anaphylaxis, while the controls were without anaphylaxis. The measure of association was odds ratio (OR) with 95% confidence interval (95%CI), using the chi-square and Fisher's exact tests. Anaphylaxis rates were calculated per doses distributed/administered. Fifteen cases and 60 controls were interviewed in 12 municipalities (counties). Anaphylaxis rates were 2.46 and 5.05 cases per 100,000 doses distributed and administered, respectively. Among the cases of anaphylaxis, eight (53.4%) were males, and among the controls, 36 (60%), with p = 0.64. The bivariate analysis of anaphylaxis and cow's milk protein allergy (CMPA) showed OR = 51.62, with p = 0.00002 and 95%CI: 5.59-476.11. The variables family food allergy, breastfeeding, previous post-vaccine adverse event (PVAE), and simultaneous vaccination were not statistically significant (p = 0.48; p = 1.00; p = 0.49; p = 0.61). Anaphylaxis rates per doses distributed/administered exceeded 1/100,000 doses administered (expected rate). Anaphylaxis and CMPA showed a statistically significant association. No statistically significant associations were found with simultaneous vaccination, breastfeeding, family food allergy, or history of PVAE. the manufacturer should specify the product's components in the package insert, and children with a history of CMPA should not be vaccinated with this vaccine.
Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Baochang; Darko, Johnson; Osei, Ernest
2016-08-15
Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneitymore » index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.« less
Sasaki, Masao S.; Tachibana, Akira; Takeda, Shunichi
2014-01-01
Cancer risk at low doses of ionizing radiation remains poorly defined because of ambiguity in the quantitative link to doses below 0.2 Sv in atomic bomb survivors in Hiroshima and Nagasaki arising from limitations in the statistical power and information available on overall radiation dose. To deal with these difficulties, a novel nonparametric statistics based on the ‘integrate-and-fire’ algorithm of artificial neural networks was developed and tested in cancer databases established by the Radiation Effects Research Foundation. The analysis revealed unique features at low doses that could not be accounted for by nominal exposure dose, including (i) the presence of a threshold that varied with organ, gender and age at exposure, and (ii) a small but significant bumping increase in cancer risk at low doses in Nagasaki that probably reflects internal exposure to 239Pu. The threshold was distinct from the canonical definition of zero effect in that it was manifested as negative excess relative risk, or suppression of background cancer rates. Such a unique tissue response at low doses of radiation exposure has been implicated in the context of the molecular basis of radiation–environment interplay in favor of recently emerging experimental evidence on DNA double-strand break repair pathway choice and its epigenetic memory by histone marking. PMID:24366315
Sasaki, Masao S; Tachibana, Akira; Takeda, Shunichi
2014-05-01
Cancer risk at low doses of ionizing radiation remains poorly defined because of ambiguity in the quantitative link to doses below 0.2 Sv in atomic bomb survivors in Hiroshima and Nagasaki arising from limitations in the statistical power and information available on overall radiation dose. To deal with these difficulties, a novel nonparametric statistics based on the 'integrate-and-fire' algorithm of artificial neural networks was developed and tested in cancer databases established by the Radiation Effects Research Foundation. The analysis revealed unique features at low doses that could not be accounted for by nominal exposure dose, including (i) the presence of a threshold that varied with organ, gender and age at exposure, and (ii) a small but significant bumping increase in cancer risk at low doses in Nagasaki that probably reflects internal exposure to (239)Pu. The threshold was distinct from the canonical definition of zero effect in that it was manifested as negative excess relative risk, or suppression of background cancer rates. Such a unique tissue response at low doses of radiation exposure has been implicated in the context of the molecular basis of radiation-environment interplay in favor of recently emerging experimental evidence on DNA double-strand break repair pathway choice and its epigenetic memory by histone marking.
Chen, Zhi-Wei; Yao, Sheng-Yu; Zhang, Tie-Ning; Zhu, Zhen-Hua; Hu, Zhe-Kai; Lu, Xun
2012-08-01
A new type of water phantom which would be specialised for the absorbed dose measurement in total body irradiation (TBI) treatment is developed. Ten millimetres of thick Plexiglas plates were arranged to form a square cube with 300 mm of edge length. An appropriate sleeve-type piston was installed on the side wall, and a tabular Plexiglas piston was positioned inside the sleeve. By pushing and pulling the piston, the length of the self-made water phantom could be varied to meet the required patients' physical sizes. To compare the international standard water phantom with the length-adjustable and the Plexiglas phantoms, absorbed dose for 6-MV X ray was measured by an ionisation chamber at different depths in three kinds of phantoms. In 70 cases with TBI, midplane doses were metered using the length-adjustable and the Plexiglas phantoms for simulating human dimensions, and dose validation was synchronously carried out. There were no significant statistical differences, p > 0.05, through statistical processing of data from the international standard water phantom and the self-designed one. There were significant statistical differences, p < 0.05, between the two sets of data from the standard and the Plexiglas one. In addition, the absolute difference had a positive correlation with the varied depth of the detector in the Plexiglas phantom. Comparing the data of clinical treatment, the differences were all <1 % among the prescription doses and the validation data collected from the self-design water phantom. However, the differences collected from the Plexiglas phantom were increasing gradually from +0.77 to +2.30 % along with increasing body width. Obviously, the difference had a positive correlation with the body width. The results proved that the new length-adjustable water phantom is more accurate for simulating human dimensions than Plexiglas phantom.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu Wei, E-mail: dr-lw@163.com; Li Yanhao, E-mail: liyanhao@fimmu.com; He Xiaofeng
Our purpose was to study necrosis and apoptosis of hepatocellular carcinoma (HCC) cells after preoperative transcatheter arterial chemoembolization (TACE) with use of low-dose and high-dose anticancer drugs in HCCs. Fifty-four patients with advanced but surgically resectable HCC were studied. Thirty-four patients who elected to undergo preoperative superselective TACE were randomized to low- and high-dose TACE. Patients in group A (n = 16) received low-dose anticancer drugs: 2 mg mitomycin C (MMC), 10 mg epirubicin (EPI), and 100 mg carboplatin (CBP). Patients in group B (n = 18) were given high doses of anticancer drugs (10 mg MMC, 40 mg EPI,more » and 300 mg CBP). Hepatic resection was subsequently performed. Group C comprised 20 patients who underwent resection without TACE. In all patients the necrosis rates and apoptosis index of tumor cells were evaluated by pathologic examinations and terminal deoxynucleotidyl transferase-mediated nick-end labeling assay. There was no significant difference between group A and group B in tumor response (p > 0.05) after TACE. Necrosis rates in groups A, B, and C were 88.4 {+-} 11.1%, 87.1 {+-} 12.5%, and 7.3 {+-} 3.5%, respectively. There was no significant difference between group A and group B (p > 0.05), while statistical difference was found between group A and group C (p < 0.001) and between group B and group C (p < 0.001). Apoptosis indexes in the three groups were 11.0 {+-} 4.0%, 10.7 {+-} 3.9%, and 5.6 {+-} 2.6%, respectively. Statistical difference exhibited between group A and group C (p < 0.001) and group B versus group C (p < 0.001). No significant difference was observed between group A and group B (p > 0.05). In conclusion, superselective TACE with low- and high-dose chemotherapeutic agents induced similar degrees of cellular apoptosis and necrosis.« less
Kraynak, A R; Barnum, J E; Cunningham, C L; Ng, A; Ykoruk, B A; Bennet, B; Stoffregen, D; Merschman, M; Freeland, E; Galloway, S M
2015-07-01
As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM) initiative international validation study of the in vivo rat alkaline comet assay (comet assay), we examined the ability of the assay to determine the genotoxicity of 2-acetylaminofluorene (AAF), azidothymidine (AZT), cisplatin (CPN), and isobutyraldehyde (IBA) in liver and glandular stomach of male Sprague-Dawley rats. Rats were given oral doses of test compound or control once daily for three days. High dose levels were approximately maximum tolerated doses and were based on preliminary range-finding studies. Tissues were harvested 3h after the final dose (48h after the initial dose). A bone marrow micronucleus assay (MN) was also conducted on the rats treated with AZT, CPN, and IBA. Acute toxic effects of treatment were determined primarily through histomorphologic analysis of liver and stomach but also by body weight and serum liver enzyme changes. The comet assay was conducted on fresh tissue preparations but frozen samples from two studies were also assayed. Statistically significant dose-related differences in comet % DNA in tail were found in liver and stomach for the genotoxin AZT and in liver for the genotoxin CPN, but not in liver or stomach for the non-genotoxin IBA. Statistically significant differences in % DNA in tail were measured in liver for the low and mid dose of the genotoxin AAF, but not the high dose. The comet assays of frozen liver suspensions from CPN- and AAF-treated rats yielded comparable results to the assays of fresh preparations. There were no indications of significant toxicity induced by any treatment. The micronucleus assay was positive for CPN and AZT and negative for IBA. In conclusion, the in vivo comet assay is capable of detecting genotoxic effects of a variety of chemicals and may fill an important role in the genotoxicity test battery. Copyright © 2015 Elsevier B.V. All rights reserved.
Clinical implementation of a knowledge based planning tool for prostate VMAT.
Powis, Richard; Bird, Andrew; Brennan, Matthew; Hinks, Susan; Newman, Hannah; Reed, Katie; Sage, John; Webster, Gareth
2017-05-08
A knowledge based planning tool has been developed and implemented for prostate VMAT radiotherapy plans providing a target average rectum dose value based on previously achievable values for similar rectum/PTV overlap. The purpose of this planning tool is to highlight sub-optimal clinical plans and to improve plan quality and consistency. A historical cohort of 97 VMAT prostate plans was interrogated using a RayStation script and used to develop a local model for predicting optimum average rectum dose based on individual anatomy. A preliminary validation study was performed whereby historical plans identified as "optimal" and "sub-optimal" by the local model were replanned in a blinded study by four experienced planners and compared to the original clinical plan to assess whether any improvement in rectum dose was observed. The predictive model was then incorporated into a RayStation script and used as part of the clinical planning process. Planners were asked to use the script during planning to provide a patient specific prediction for optimum average rectum dose and to optimise the plan accordingly. Plans identified as "sub-optimal" in the validation study observed a statistically significant improvement in average rectum dose compared to the clinical plan when replanned whereas plans that were identified as "optimal" observed no improvement when replanned. This provided confidence that the local model can identify plans that were suboptimal in terms of rectal sparing. Clinical implementation of the knowledge based planning tool reduced the population-averaged mean rectum dose by 5.6Gy. There was a small but statistically significant increase in total MU and femoral head dose and a reduction in conformity index. These did not affect the clinical acceptability of the plans and no significant changes to other plan quality metrics were observed. The knowledge-based planning tool has enabled substantial reductions in population-averaged mean rectum dose for prostate VMAT patients. This suggests plans are improved when planners receive quantitative feedback on plan quality against historical data.
90-Day oral toxicity study of D-tagatose in rats.
Kruger, C L; Whittaker, M H; Frankos, V H; Trimmer, G W
1999-04-01
D-tagatose is a ketohexose, tastes like sugar and is useful as a low-calorie sweetener. To assess D-tagatose's safety, an oral 90-day toxicity study was conducted on male and female Crl:CDBR rats at dietary doses of 5, 10, 15, and 20% D-tagatose. One control group (dietary control) received only lab chow; a second control group received 20% cellulose/fructose in the diet. There were no treatment-related effects at 5% D-tagatose in the diet. At higher doses, treatment-related effects included transient soft stools in male and female animals from the 15 and 20% dose groups. This was anticipated as a result of the osmotic effect of a large dose of relatively undigested sugar and was not considered a toxic effect. All treatment groups gained weight over the study period; however, mean body weights were statistically significantly decreased in the 15 and 20% dose-group males and the 20% dose-group females at selected intervals compared to dietary control animals. No significant reduction in mean food consumption was noted in the treatment groups compared to the dietary control. Statistically significantly increased relative liver weights were noted in male and female animals from the 10, 15, and 20% dose groups compared to the dietary control. No gross pathological findings correlated with these increased liver weights. Minimal hepatocellular hypertrophy was observed in male and female animals from the 15 and 20% dose groups. An independent review of the liver slides concluded that histomorphologic changes associated with D-tagatose were restricted hepatocyte hypertrophy and hepatocyte glycogen accumulation. Therefore, it was concluded that increased liver weights and minimal hypertrophy were the result of adaptation to the high dietary levels (greater than 5% in the diet) of D-tagatose. No adverse effects were seen at 5% D-tagatose in the diet. Copyright 1999 Academic Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Y
2016-06-15
Purpose: To test the impact of the use of apex optimization points for new vaginal cylinder (VC) applicators. Methods: New “ClickFit” single channel VC applicators (Varian) that have a different top thicknesses but the same diameters as the old VC applicators (2.3 cm diameter, 2.6 cm, 3.0 cm, and 3.5 cm) were compared using phantom studies. Old VC applicator plans without apex optimization points were also compared to the plans with the optimization points. The apex doses were monitored at 5 mm depth doses (8 points) where a prescription dose (Rx) of 6Gy was prescribed. VC surface doses (8 points)more » were also analyzed. Results: The new VC applicator plans without apex optimization points presented significantly lower 5mm depth doses than Rx (on average −31 ± 7%, p <0.00001) due to their thicker VC tops (3.4 ± 1.1 mm thicker with the range of 1.2 to 4.4 mm) than the old VC applicators. Old VC applicator plans also showed a statistically significant reduction (p <0.00001) due to Ir-192 source anisotropic effect at the apex region but the % reduction over Rx was only −7 ± 9%. However, by adding apex optimization points to the new VC applicator plans, the plans improved 5 mm depth doses (−7 ± 9% over Rx) that were not statistically different from old VC plans (p = 0.923), along with apex VC surface doses (−22 ± 10% over old VC versus −46 ± 7% without using apex optimization points). Conclusion: The use of apex optimization points are important in order to avoid significant additional cold doses (−24 ± 2%) at the prescription depth (5 mm) of apex, especially for the new VC applicators that have thicker tops.« less
Optimisation of radiation dose and image quality in mobile neonatal chest radiography.
Hinojos-Armendáriz, V I; Mejía-Rosales, S J; Franco-Cabrera, M C
2018-05-01
To optimise the radiation dose and image quality for chest radiography in the neonatal intensive care unit (NICU) by increasing the mean beam energy. Two techniques for the acquisition of NICU AP chest X-ray images were compared for image quality and radiation dose. 73 images were acquired using a standard technique (56 kV, 3.2 mAs and no additional filtration) and 90 images with a new technique (62 kV, 2 mAs and 2 mm Al filtration). The entrance surface air kerma (ESAK) was measured using a phantom and compared between the techniques and against established diagnostic reference levels (DRL). Images were evaluated using seven image quality criteria independently by three radiologists. Images quality and radiation dose were compared statistically between the standard and new techniques. The maximum ESAK for the new technique was 40.20 μGy, 43.7% of the ESAK of the standard technique. Statistical evaluation demonstrated no significant differences in image quality between the two acquisition techniques. Based on the techniques and acquisition factors investigated within this study, it is possible to lower the radiation dose without any significant effects on image quality by adding filtration (2 mm Al) and increasing the tube potential. Such steps are relatively simple to undertake and as such, other departments should consider testing and implementing this dose reduction strategy within clinical practice where appropriate. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Blonanserin – A Novel Antianxiety and Antidepressant Drug? An Experimental Study
Limaye, Ramchandra Prabhakar; Patil, Aditi Nitin
2016-01-01
Introduction Many psychiatric disorders show signs and symptoms of anxiety and depression. A drug with both, effects and lesser adverse effects is always desired. Blonanserin is a novel drug with postulated effect on anxiety and depression. Aim The study was aimed to evaluate the effect of Blonanserin on anxiety and depression in animal models. Materials and Methods By using elevated plus maze test and forced swimming test, the antianxiety and antidepressant effects were evaluated. Animal ethics protocols were followed strictly. Total 50 rats (10 rats per group) were used for each test. As a control drug diazepam and imipramine were used in elevated plus maze and forced swimming test respectively. Blonanserin was tested for 3 doses 0.075, 0.2 and 0.8mg. These doses were selected from previous references as well as by extrapolating human doses. Results This study showed an antianxiety effect of Blonanserin comparable to diazepam, which was statistically significant. Optimal effect was observed with 0.075mg, followed by 0.2 and 0.8mg. It also showed an antidepressant effect which was statistically significant. Optimal effect was observed at 0.2mg dose. Conclusion The results showed that at a dose range of 0.075 and 0.2mg Blonanserin has potential to exert an adjuvant antianxiety and antidepressant activity in animal models. In order to extrapolate this in patient, longer clinical studies with comparable doses should be planned. The present study underlines potential of Blonanserin as a novel drug for such studies. PMID:27790460
Blonanserin - A Novel Antianxiety and Antidepressant Drug? An Experimental Study.
Limaye, Ramchandra Prabhakar; Patil, Aditi Nitin
2016-09-01
Many psychiatric disorders show signs and symptoms of anxiety and depression. A drug with both, effects and lesser adverse effects is always desired. Blonanserin is a novel drug with postulated effect on anxiety and depression. The study was aimed to evaluate the effect of Blonanserin on anxiety and depression in animal models. By using elevated plus maze test and forced swimming test, the antianxiety and antidepressant effects were evaluated. Animal ethics protocols were followed strictly. Total 50 rats (10 rats per group) were used for each test. As a control drug diazepam and imipramine were used in elevated plus maze and forced swimming test respectively. Blonanserin was tested for 3 doses 0.075, 0.2 and 0.8mg. These doses were selected from previous references as well as by extrapolating human doses. This study showed an antianxiety effect of Blonanserin comparable to diazepam, which was statistically significant. Optimal effect was observed with 0.075mg, followed by 0.2 and 0.8mg. It also showed an antidepressant effect which was statistically significant. Optimal effect was observed at 0.2mg dose. The results showed that at a dose range of 0.075 and 0.2mg Blonanserin has potential to exert an adjuvant antianxiety and antidepressant activity in animal models. In order to extrapolate this in patient, longer clinical studies with comparable doses should be planned. The present study underlines potential of Blonanserin as a novel drug for such studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Ellen X.; Bradley, Jeffrey D.; El Naqa, Issam
2012-04-01
Purpose: To construct a maximally predictive model of the risk of severe acute esophagitis (AE) for patients who receive definitive radiation therapy (RT) for non-small-cell lung cancer. Methods and Materials: The dataset includes Washington University and RTOG 93-11 clinical trial data (events/patients: 120/374, WUSTL = 101/237, RTOG9311 = 19/137). Statistical model building was performed based on dosimetric and clinical parameters (patient age, sex, weight loss, pretreatment chemotherapy, concurrent chemotherapy, fraction size). A wide range of dose-volume parameters were extracted from dearchived treatment plans, including Dx, Vx, MOHx (mean of hottest x% volume), MOCx (mean of coldest x% volume), and gEUDmore » (generalized equivalent uniform dose) values. Results: The most significant single parameters for predicting acute esophagitis (RTOG Grade 2 or greater) were MOH85, mean esophagus dose (MED), and V30. A superior-inferior weighted dose-center position was derived but not found to be significant. Fraction size was found to be significant on univariate logistic analysis (Spearman R = 0.421, p < 0.00001) but not multivariate logistic modeling. Cross-validation model building was used to determine that an optimal model size needed only two parameters (MOH85 and concurrent chemotherapy, robustly selected on bootstrap model-rebuilding). Mean esophagus dose (MED) is preferred instead of MOH85, as it gives nearly the same statistical performance and is easier to compute. AE risk is given as a logistic function of (0.0688 Asterisk-Operator MED+1.50 Asterisk-Operator ConChemo-3.13), where MED is in Gy and ConChemo is either 1 (yes) if concurrent chemotherapy was given, or 0 (no). This model correlates to the observed risk of AE with a Spearman coefficient of 0.629 (p < 0.000001). Conclusions: Multivariate statistical model building with cross-validation suggests that a two-variable logistic model based on mean dose and the use of concurrent chemotherapy robustly predicts acute esophagitis risk in combined-data WUSTL and RTOG 93-11 trial datasets.« less
Sheashaa, Hussein; Abdel-Razek, Waleed; El-Husseini, Amr; Selim, Amal; Hassan, Nabil; Abbas, Tarek; El-Askalani, Hassan; Sobh, Mohamed
2005-01-01
Use of androgen as an adjuvant therapy to treat anemia in patients on hemodialysis is debated. Our target is to assess the safety and the efficacy of nandrolone decanoate (ND) as an effective adjunctive therapy to treat such anemia. This study included 32 anemic adult hemodialysis patients who had adequate iron stores. They were randomized into two equal groups: the first group received subcutaneously a low dose of erythropoietin (EPO) 1,000 U three times weekly combined with ND, 50 mg intramuscularly twice weekly, and the second group received only the same low dose of EPO for the 6-month study period. All patients were subjected to a serial follow-up of hemoglobin (Hb), hematocrit % (Hct%), iron store indices, serum insulin-like growth factor-1 (IGF-1) concentration and liver function tests. A significant rise of both Hb and Hct in both groups was found at the end of the study (p < 0.001). Although the rise of both Hb and Hct was higher in the androgen group, it was not rated as being statistically significant. Both groups showed a significant rise of serum IGF-1 concentration at the end of the study in comparison to its initial value. Moreover, the androgen group attained a more statistically significant rise of IGF-1 serum concentration. Four female patients discontinued ND because of related adverse effects, principally distressing hirsutism and hepatic dysfunction. Addition of ND to a low-dose EPO regimen does not offer a significant benefit. Androgen-related side effects limit its use in female patients.
[Effect of Biochar on Soil Greenhouse Gas Emissions in Semi-arid Region].
Guo, Yan-liang; Wang, Dan-dan; Zheng, Ji-yong; Zhao, Shi-wei; Zhang, Xing-chang
2015-09-01
This study aimed to investigate the effects of biochar addition on the emission of greenhouse gases from farmland soil in semi-arid region. Through an in-situ experiments, the influence of sawdust biochar(J) and locust tree skin biochar (H) at three doses (1%, 3%, and 5% of quality percentage) on C2, CH4 and N2O emissions were studied within the six months in the south of Ningxiaprovince. The results indicated that soil CO2 emission flux was slightly increased with the addition doses for both biochars, and the averaged CO2 emission flux for sawdust and locust tree skin biochar was enhanced by 1. 89% and 3. 34% compared to the control, but the difference between treatments was not statistically significant. The soil CH4 emission was decreased with the increasing of biochar doses, by 1. 17%, 2. 55%, 4. 32% for J1, J3, J5 and 2. 35%, 5. 83%, 7. 32% for H1, H3, H5, respectively. However, the difference was statistically significant only for J5, H3 and H5 treatments (P <0. 05). Across addition doses, there was no apparent effect on soil N2O emission. Our study indicated that the biochar has no significant influence on soil CO2 and N2O emissions within six months in semi-arid region and can significantly influence soil CH4 emissions (P < 0. 05). As for biochar type, the locust tree skin biochar is significantly better than the sawdust biochar in terms of restraining CH4 emission(P = 0. 048).
Kaynar, Mehmet; Tekinarslan, Erdem; Keskin, Suat; Buldu, İbrahim; Sönmez, Mehmet Giray; Karatag, Tuna; Istanbulluoglu, Mustafa Okan
2015-01-01
To determine and evaluate the effective radiation exposure during a one year follow-up of urolithiasis patients following the SWL (extracorporeal shock wave lithotripsy) treatment. Total Effective Radiation Exposure (ERE) doses for each of the 129 patients: 44 kidney stone patients, 41 ureter stone patients, and 44 multiple stone location patients were calculated by adding up the radiation doses of each ionizing radiation session including images (IVU, KUB, CT) throughout a one year follow-up period following the SWL. Total mean ERE values for the kidney stone group was calculated as 15, 91 mSv (5.10-27.60), for the ureter group as 13.32 mSv (5.10-24.70), and in the multiple stone location group as 27.02 mSv (9.41-54.85). There was no statistically significant differences between the kidney and ureter groups in terms of the ERE dose values (p = 0.221) (p >0.05). In the comparison of the kidney and ureter stone groups with the multiple stone location group; however, there was a statistically significant difference (p = 0.000) (p <0.05). ERE doses should be a factor to be considered right at the initiation of any diagnostic and/or therapeutic procedure. Especially in the case of multiple stone locations, due to the high exposure to ionized radiation, different imaging modalities with low dose and/or totally without a dose should be employed in the diagnosis, treatment, and follow-up bearing the aim to optimize diagnosis while minimizing the radiation dose as much as possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huddart, Robert A., E-mail: robert.huddart@icr.ac.uk; Hall, Emma; Hussain, Syed A.
2013-10-01
Purpose: To test whether reducing radiation dose to uninvolved bladder while maintaining dose to the tumor would reduce side effects without impairing local control in the treatment of muscle-invasive bladder cancer. Methods and Materials: In this phase III multicenter trial, 219 patients were randomized to standard whole-bladder radiation therapy (sRT) or reduced high-dose volume radiation therapy (RHDVRT) that aimed to deliver full radiation dose to the tumor and 80% of maximum dose to the uninvolved bladder. Participants were also randomly assigned to receive radiation therapy alone or radiation therapy plus chemotherapy in a partial 2 × 2 factorial design. Themore » primary endpoints for the radiation therapy volume comparison were late toxicity and time to locoregional recurrence (with a noninferiority margin of 10% at 2 years). Results: Overall incidence of late toxicity was less than predicted, with a cumulative 2-year Radiation Therapy Oncology Group grade 3/4 toxicity rate of 13% (95% confidence interval 8%, 20%) and no statistically significant differences between groups. The difference in 2-year locoregional recurrence free rate (RHDVRT − sRT) was 6.4% (95% confidence interval −7.3%, 16.8%) under an intention to treat analysis and 2.6% (−12.8%, 14.6%) in the “per-protocol” population. Conclusions: In this study RHDVRT did not result in a statistically significant reduction in late side effects compared with sRT, and noninferiority of locoregional control could not be concluded formally. However, overall low rates of clinically significant toxicity combined with low rates of invasive bladder cancer relapse confirm that (chemo)radiation therapy is a valid option for the treatment of muscle-invasive bladder cancer.« less
Manor, Iris; Rubin, Jonathan; Daniely, Yaron; Adler, Lenard A
2014-09-01
To assess the first-dose effectiveness and tolerability of metadoxine extended release (MDX) in adults with predominantly inattentive attention-deficit/hyperactivity disorder (ADHD-PI). In this double-blind, placebo-controlled, crossover study, adults with ADHD-PI were randomized 1:1:1 to receive a single dose of MDX 1400 mg, MDX 700 mg, and placebo (ClinicalTrials.gov identifier: NCT01685281). The primary efficacy end point was the mean change in the Test of Variables of Attention (TOVA) ADHD score from baseline to 3 to 5 hours after drug administration. Secondary assessments included TOVA subscores, TOVA response rates (defined as an increase of 0.8 points in the TOVA ADHD score), and the Cambridge Neuropsychological Automated Test Battery. Safety assessments included adverse events and vital signs. The intention-to-treat population included 36 patients (52.8% men; mean age, 32 years). The efficacy of MDX 1400 mg was demonstrated by a statistically significant difference in the mean (± SD) change in the TOVA ADHD score at baseline to 3 to 5 hours after drug administration compared with placebo (2.0 [4.2]; P = 0.009). The TOVA response time variability subscore was significantly different between MDX 1400 mg and placebo (mean difference, 7.9 [19.2] points; P = 0.022). Significantly more adults responded to single-dose MDX 1400 mg versus placebo (97.1% vs 71.4%, P = 0.006). There were no statistically significant differences between MDX 700 mg and placebo on any measures. Exploratory analyses of the Cambridge Neuropsychological Automated Test Battery did not yield significant findings. Fatigue and headache were the 2 most frequently reported adverse events. There were no clinically significant abnormalities in laboratory values, vital signs measurements, Columbia-Suicide Severity Rating Scale scores, or electrocardiographic parameters. Single-dose MDX 1400 mg significantly improved sustained and selective attention in adults with ADHD-PI as measured by the TOVA ADHD score 3 to 5 hours after drug administration. Single doses of MDX 700 and 1400 mg were well tolerated.
Clinical radiobiology of stage T2-T3 bladder cancer.
Majewski, Wojciech; Maciejewski, Boguslaw; Majewski, Stanislaw; Suwinski, Rafal; Miszczyk, Leszek; Tarnawski, Rafal
2004-09-01
To evaluate the relationship between total radiation dose and overall treatment time (OTT) with the treatment outcome, with adjustment for selected clinical factors, in patients with Stage T2-T3 bladder cancer treated with curative radiotherapy (RT). The analysis was based on 480 patients with Stage T2-T3 bladder cancer who were treated at the Center of Oncology in Gliwice between 1975 and 1995. The mean total radiation dose was 65.5 Gy, and the mean OTT was 51 days. In 261 patients (54%), planned and unplanned gaps occurred during RT. Four fractionation schedules were used: (1) conventional fractionation (once daily, 1.8-2.5 Gy/fraction); (2) protracted fractionation (pelvic RT, once daily, 1.6-1.7 Gy/fraction, boost RT, once daily, 2.0 Gy/fraction); (3) accelerated hyperfractionated boost (pelvic RT, once daily, 2.0 Gy/fraction; boost RT, twice daily, 1.3-1.4 Gy/fraction); and (4) accelerated hyperfractionation (pelvic and boost RT, twice daily, 1.2-1.5 Gy/fraction). In all fractionation schedules, the total radiation dose was similar (average 65.5 Gy), but the OTT was different (mean 53 days for conventional fractionation, 62 days for protracted fractionation, 45 days for accelerated hyperfractionated boost, and 41 days for accelerated hyperfractionation). A Cox proportional hazard model and maximum likelihood logistic model were used to evaluate the relationship between the treatment-related parameters (total radiation dose, dose per fraction, and OTT) and clinical factors (clinical T stage, hemoglobin level and bladder capacity before RT) and treatment outcome. With a median follow-up of 76 months, the actuarial 5-year local control rate was 47%, and the overall survival rate was 40%. The logistic analysis, which included the total dose, OTT, and T stage, revealed that all of these factors were significantly related to tumor control probability (p = 0.021 for total radiation dose, p = 0.038 for OTT, and p = 0.00068 for T stage). A multivariate Cox model, which included the treatment-related parameters and other clinical factors, revealed that the hemoglobin level and bladder capacity before RT and T-stage were statistically significant factors determining local control and overall survival. The total radiation dose was of borderline statistical significance for overall survival (p = 0.087), and OTT did not reach statistical significance. The results of our study showed that the treatment outcome after RT for bladder cancer depends mainly on clinical factors: hemoglobin level and bladder capacity before RT, and clinical T stage. An increase in the total radiation dose seemed to be associated with a better treatment outcome. The effect of the OTT was difficult to define, because it was influenced by other prognostic factors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watkins, W.T.; Siebers, J.V.
Purpose: To introduce quasi-constrained Multi-Criteria Optimization (qcMCO) for unsupervised radiation therapy optimization which generates alternative patient-specific plans emphasizing dosimetric tradeoffs and conformance to clinical constraints for multiple delivery techniques. Methods: For N Organs At Risk (OARs) and M delivery techniques, qcMCO generates M(N+1) alternative treatment plans per patient. Objective weight variations for OARs and targets are used to generate alternative qcMCO plans. For 30 locally advanced lung cancer patients, qcMCO plans were generated for dosimetric tradeoffs to four OARs: each lung, heart, and esophagus (N=4) and 4 delivery techniques (simple 4-field arrangements, 9-field coplanar IMRT, 27-field non-coplanar IMRT, and non-coplanarmore » Arc IMRT). Quasi-constrained objectives included target prescription isodose to 95% (PTV-D95), maximum PTV dose (PTV-Dmax)< 110% of prescription, and spinal cord Dmax<45 Gy. The algorithm’s ability to meet these constraints while simultaneously revealing dosimetric tradeoffs was investigated. Statistically significant dosimetric tradeoffs were defined such that the coefficient of determination between dosimetric indices which varied by at least 5 Gy between different plans was >0.8. Results: The qcMCO plans varied mean dose by >5 Gy to ipsilateral lung for 24/30 patients, contralateral lung for 29/30 patients, esophagus for 29/30 patients, and heart for 19/30 patients. In the 600 plans computed without human interaction, average PTV-D95=67.4±3.3 Gy, PTV-Dmax=79.2±5.3 Gy, and spinal cord Dmax was >45 Gy in 93 plans (>50 Gy in 2/600 plans). Statistically significant dosimetric tradeoffs were evident in 19/30 plans, including multiple tradeoffs of at least 5 Gy between multiple OARs in 7/30 cases. The most common statistically significant tradeoff was increasing PTV-Dmax to reduce OAR dose (15/30 patients). Conclusion: The qcMCO method can conform to quasi-constrained objectives while revealing significant variations in OAR doses including mean dose reductions >5 Gy. Clinical implementation will facilitate patient-specific decision making based on achievable dosimetry as opposed to accept/reject models based on population derived objectives.« less
Low-dose CT image reconstruction using gain intervention-based dictionary learning
NASA Astrophysics Data System (ADS)
Pathak, Yadunath; Arya, K. V.; Tiwari, Shailendra
2018-05-01
Computed tomography (CT) approach is extensively utilized in clinical diagnoses. However, X-ray residue in human body may introduce somatic damage such as cancer. Owing to radiation risk, research has focused on the radiation exposure distributed to patients through CT investigations. Therefore, low-dose CT has become a significant research area. Many researchers have proposed different low-dose CT reconstruction techniques. But, these techniques suffer from various issues such as over smoothing, artifacts, noise, etc. Therefore, in this paper, we have proposed a novel integrated low-dose CT reconstruction technique. The proposed technique utilizes global dictionary-based statistical iterative reconstruction (GDSIR) and adaptive dictionary-based statistical iterative reconstruction (ADSIR)-based reconstruction techniques. In case the dictionary (D) is predetermined, then GDSIR can be used and if D is adaptively defined then ADSIR is appropriate choice. The gain intervention-based filter is also used as a post-processing technique for removing the artifacts from low-dose CT reconstructed images. Experiments have been done by considering the proposed and other low-dose CT reconstruction techniques on well-known benchmark CT images. Extensive experiments have shown that the proposed technique outperforms the available approaches.
2017-01-01
Epilepsy is a neurological disorder that affects approximately one percent of the world population. Noninvasive electrical brain stimulation via tripolar concentric ring electrodes has been proposed as an alternative/complementary therapy for seizure control. Previous results suggest its efficacy attenuating acute seizures in penicillin, pilocarpine-induced status epilepticus, and pentylenetetrazole-induced rat seizure models and its safety for the rat scalp, cortical integrity, and memory formation. In this study, neuronal counting was used to assess possible tissue damage in rats (n = 36) due to the single dose or five doses (given every 24 hours) of stimulation on hippocampal CA3 subregion neurons 24 hours, one week, and one month after the last stimulation dose. Full factorial analysis of variance showed no statistically significant difference in the number of neurons between control and stimulation-treated animals (p = 0.71). Moreover, it showed no statistically significant differences due to the number of stimulation doses (p = 0.71) nor due to the delay after the last stimulation dose (p = 0.96). Obtained results suggest that stimulation at current parameters (50 mA, 200 μs, 300 Hz, biphasic, charge-balanced pulses for 2 minutes) does not induce neuronal damage in the hippocampal CA3 subregion of the brain. PMID:29065603
Mucio-Ramírez, Samuel; Makeyev, Oleksandr
2017-01-01
Epilepsy is a neurological disorder that affects approximately one percent of the world population. Noninvasive electrical brain stimulation via tripolar concentric ring electrodes has been proposed as an alternative/complementary therapy for seizure control. Previous results suggest its efficacy attenuating acute seizures in penicillin, pilocarpine-induced status epilepticus, and pentylenetetrazole-induced rat seizure models and its safety for the rat scalp, cortical integrity, and memory formation. In this study, neuronal counting was used to assess possible tissue damage in rats ( n = 36) due to the single dose or five doses (given every 24 hours) of stimulation on hippocampal CA3 subregion neurons 24 hours, one week, and one month after the last stimulation dose. Full factorial analysis of variance showed no statistically significant difference in the number of neurons between control and stimulation-treated animals ( p = 0.71). Moreover, it showed no statistically significant differences due to the number of stimulation doses ( p = 0.71) nor due to the delay after the last stimulation dose ( p = 0.96). Obtained results suggest that stimulation at current parameters (50 mA, 200 μ s, 300 Hz, biphasic, charge-balanced pulses for 2 minutes) does not induce neuronal damage in the hippocampal CA3 subregion of the brain.
Ahmad, Hesham M
2015-01-01
Acne vulgaris is a debilitating disorder and requires proper treatment. This work evaluates the clinical efficacy, side effects, and laboratory changes of serum lipids and liver function during oral isotretinoin therapy for acne vulgaris, comparing single versus twice daily dose. Fifty-eight patients with acne vulgaris were included and randomized into group I (26 patients), who received once daily dose, and group II (32 patients), who received twice daily dose of oral isotretinoin. Global acne scoring system was used to evaluate acne severity and post-treatment improvement. Both regimens resulted in highly significant clinical improvement of acne with no significant difference. However, side effects were significantly more common among patients of group I. Both regimens caused mild rise of serum cholesterol, alanine transaminase (ALT), and aspartate aminotransferase (AST) with more prominent rise of triglycerides especially with twice daily dose. Oral isotretinoin is a very effective treatment for acne vulgaris with no statistically significant difference in clinical efficacy between once and twice daily doses. However, dividing dose to twice per day might cause fewer incidence of side effects without reducing clinical efficacy. The drug causes mild clinically insignificant rise of serum cholesterol, triglycerides, AST, and ALT. © 2015 Wiley Periodicals, Inc.
Perez, Alfonso; Cao, Charlie
2017-01-01
This was a phase 2, multicenter, randomized, parallel-group, double-blind dose-ranging study. Hypertensive adults (n=555) received one of five doses of azilsartan (AZL; 2.5, 5, 10, 20, 40 mg), olmesartan medoxomil (OLM) 20 mg, or placebo once daily. The primary endpoint was change in trough clinic diastolic blood pressure (DBP) at week 8. Compared with placebo, all AZL doses (except 2.5 mg) provided statistically and clinically significant reductions in DBP and systolic blood pressure (SBP) based on both clinic blood pressure (BP) and 24-hour ambulatory BP monitoring (ABPM). AZL 40 mg was statistically superior vs OLM. Clinic BP was associated with a pronounced placebo effect (-6 mm Hg), whereas this was negligible with ABPM (±0.5 mm Hg). Adverse event frequency was similar in the AZL and placebo groups. Based on these and other findings, subsequent trials investigated the commercial AZL medoxomil tablet at doses 20 to 80 mg/d using 24-hour ABPM. ©2016 Wiley Periodicals, Inc.
Zablotska, Lydia B; Lane, Rachel S D; Frost, Stanley E; Thompson, Patsy A
2014-04-01
Uranium workers are chronically exposed to low levels of radon decay products (RDP) and gamma (γ) radiation. Risks of leukemia from acute and high doses of γ-radiation are well-characterized, but risks from lower doses and dose-rates and from RDP exposures are controversial. Few studies have evaluated risks of other hematologic cancers in uranium workers. The purpose of this study was to analyze radiation-related risks of hematologic cancers in the cohort of Eldorado uranium miners and processors first employed in 1932-1980 in relation to cumulative RDP exposures and γ-ray doses. The average cumulative RDP exposure was 100.2 working level months and the average cumulative whole-body γ-radiation dose was 52.2 millisievert. We identified 101 deaths and 160 cases of hematologic cancers in the cohort. Overall, male workers had lower mortality and cancer incidence rates for all outcomes compared with the general Canadian male population, a likely healthy worker effect. No statistically significant association between RDP exposure or γ-ray doses, or a combination of both, and mortality or incidence of any hematologic cancer was found. We observed consistent but non-statistically significant increases in risks of chronic lymphocytic leukemia (CLL) and Hodgkin lymphoma (HL) incidence and non-Hodgkin lymphoma (NHL) mortality with increasing γ-ray doses. These findings are consistent with recent studies of increased risks of CLL and NHL incidence after γ-radiation exposure. Further research is necessary to understand risks of other hematologic cancers from low-dose exposures to γ-radiation. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni
2016-01-01
Iterative reconstruction methods have attracted attention for reducing radiation doses in computed tomography (CT). To investigate the detectability of pancreatic calcification using dose-reduced CT reconstructed with model-based iterative construction (MBIR) and adaptive statistical iterative reconstruction (ASIR). This prospective study approved by Institutional Review Board included 85 patients (57 men, 28 women; mean age, 69.9 years; mean body weight, 61.2 kg). Unenhanced CT was performed three times with different radiation doses (reference-dose CT [RDCT], low-dose CT [LDCT], ultralow-dose CT [ULDCT]). From RDCT, LDCT, and ULDCT, images were reconstructed with filtered-back projection (R-FBP, used for establishing reference standard), ASIR (L-ASIR), and MBIR and ASIR (UL-MBIR and UL-ASIR), respectively. A lesion (pancreatic calcification) detection test was performed by two blinded radiologists with a five-point certainty level scale. Dose-length products of RDCT, LDCT, and ULDCT were 410, 97, and 36 mGy-cm, respectively. Nine patients had pancreatic calcification. The sensitivity for detecting pancreatic calcification with UL-MBIR was high (0.67-0.89) compared to L-ASIR or UL-ASIR (0.11-0.44), and a significant difference was seen between UL-MBIR and UL-ASIR for one reader (P = 0.014). The area under the receiver-operating characteristic curve for UL-MBIR (0.818-0.860) was comparable to that for L-ASIR (0.696-0.844). The specificity was lower with UL-MBIR (0.79-0.92) than with L-ASIR or UL-ASIR (0.96-0.99), and a significant difference was seen for one reader (P < 0.01). In UL-MBIR, pancreatic calcification can be detected with high sensitivity, however, we should pay attention to the slightly lower specificity.
SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonkopi, E; Abdolell, M; Duffy, S
2015-06-15
Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentilemore » of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan
To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plansmore » were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.« less
Ji, Z; Jiang, Y L; Guo, F X; Peng, R; Sun, H T; Fan, J H; Wang, J J
2017-04-04
Objective: To compare the dose distributions of postoperative plans with preoperative plans for seeds implantations of paravertebral/retroperitoneal tumors assisted by 3D printing guide template and CT guidance, explore the effects of the technology for seeds implantations in dosimetry level and provide data support for the optimization and standardization in seeds implantation. Methods: Between December 2015 and July 2016, a total of 10 patients with paravertebral/retroperitoneal tumors (12 lesions) received 3D printing template assist radioactive seeds implantations in department of radiation oncology of Peking University Third Hospital, and included in the study. The diseases included cervical cancer, kidney cancer, abdominal stromal tumor, leiomyosarcoma of kidney, esophageal cancer and carcinoma of ureter. The prescribed doses was 110-150 Gy. All patients received preoperative planning design, individual template design and production, and the dose distribution of postoperative plan was compared with preoperative plan. Dose parameters including D(90), MPD, V(100), V(150,)conformal index(CI), EI of target volume and D(2cc) of organs at risk (spinal cord, aorta, kidney). Statistical software was SPSS 19.0 and statistical method was non-parameters Wilcoxon symbols test. Results: A total of 10 3D printing templates were designed and produced which were including 12 treatment areas.The mean D(90) of postoperative target area (GTV) was 131.1 (97.8-167.4 Gy) Gy. The actual seeds number of post operation increased by 3 to 12 in 5 cases (42.0%). The needle was well distributed. For postoperative plans, the mean D(90,)MPD, V(100,)V(150) was 131.1 Gy, 69.3 Gy, 90.2% and 65.2%, respectively, and which was 140.2 Gy, 65.6 Gy, 91.7% and 26.8%, respectively, in preoperative plans. This meant that the actual dose of target volume was slightly lower than preplanned dose, and the high dose area of target volume was larger than preplanned range, but there was no statistical difference in P value between the two groups except V(150)( P =0.004). The actual dose conformity of target volume was worse than preplanned (CI was 0.58 and 0.62, respectively) and the difference was statistically significant( P =0.019). The actual dose of external target volume was higher than preplanned (EI was 55% and 45.9%, respectively) and the difference had no significance. For organs at risk, the actual mean D(2cc) of spinal cord, aorta and kidney was 24.7, 54.4 and 29.7 Gy, respectively, which was higher than preplanned(20.6, 51.6 and 28.6 Gy, respectively), and there was no significant difference in two groups. Conclusions: Most parameters of postoperative validations for 3D printing template assisted seeds implantation in paravertebral/retroperitoneal are closed to the expectations of preoperative plans which means the improvement of accuracy in treatment.
Kamran, Sophia C.; Manuel, Matthias M.; Cho, Linda P.; Damato, Antonio L.; Schmidt, Ehud J.; Tempany, Clare; Cormack, Robert A.; Viswanathan, Akila N.
2017-01-01
Objective The purpose was to compare local control (LC), overall survival (OS) and dose to the organs at risk (OAR) in women with locally advanced cervical cancer treated with MR-guided versus CT-guided interstitial brachytherapy (BT). Methods 56 patients (29 MR, 27 CT) were treated with high-dose-rate (HDR) interstitial BT between 2005–2015. The MR patients had been prospectively enrolled on a Phase II clinical trial. Data were analyzed using Kaplan-Meier (K-M) and Cox proportional hazards statistical modeling in JMP® & R®. Results Median follow-up time was 19.7 months (MR group) and 18.4 months (CT group). There were no statistically significant differences in patient age at diagnosis, histology, percent with tumor size >4 cm, grade, FIGO stage or lymph node involvement between the groups. Patients in the MR group had more lymphovascular involvement compared to patients in the CT group (p<0.01). When evaluating plans generated, there were no statistically significant differences in median cumulative dose to the high-risk clinical target volume or the OAR. 2-year K-M LC rates for MR-based and CT-based treatments were 96% and 87%, respectively (log-rank p=0.65). At 2 years, OS was significantly better in the MR-guided cohort (84% vs. 56%, p=0.036). On multivariate analysis, squamous histology was associated with longer OS (HR 0.23, 95% CI 0.07–0.72) in a model with MR BT (HR 0.35, 95% CI 0.08–1.18). Conclusion In this population of locally advanced cervical-cancer patients, MR-guided HDR BT resulted in estimated 96% 2-year local control and excellent early survival rates. Squamous cell histology was the most significant predictor for survival. PMID:28318644
The value of thyroid shielding in intraoral radiography
Hazenoot, Bart; Sanderink, Gerard C H; Berkhout, W Erwin R
2016-01-01
Objectives: To evaluate the utility of the application of a thyroid shield in intraoral radiography when using rectangular collimation. Methods: Experimental data were obtained by measuring the absorbed dose at the position of the thyroid gland in a RANDO® (The Phantom Laboratory, Salem, NY) male phantom with a dosemeter. Four protocols were tested: round collimation and rectangular collimation, both with and without thyroid shield. Five exposure positions were deployed: upper incisor (Isup), upper canine (Csup), upper premolar (Psup), upper molar (Msup) and posterior bitewing (BW). Exposures were made with 70 kV and 7 mA and were repeated 10 times. The exposure times were as recommended for the exposure positions for the respective collimator type by the manufacturer for digital imaging. The data were statistically analyzed with a three-way ANOVA test. Significance was set at p < 0.01. Results: The ANOVA test revealed that the differences between mean doses of all protocols and geometries were statistically significant, p < 0.001. For the Isup, thyroid dose levels were comparable with both collimators at a level indicating primary beam exposure. Thyroid shield reduced this dose with circa 75%. For the Csup position, round collimation also revealed primary beam exposure, and thyroid shield yield was 70%. In Csup with rectangular collimation, the thyroid dose was reduced with a factor 4 compared with round collimation and thyroid shield yielded an additional 42% dose reduction. The thyroid dose levels for the Csup, Psup, Msup and BW exposures were lower with rectangular collimation without thyroid shield than with round collimation with thyroid shield. With rectangular collimation, the thyroid shield in Psup, Msup and BW reduced the dose 10% or less, where dose levels were already low, implying no clinical significance. Conclusions: For the exposures in the upper anterior region, thyroid shield results in an important dose reduction for the thyroid. For the other exposures, thyroid shield augments little to the reduction achieved by rectangular collimation. The use of thyroid shield is to be advised, when performing upper anterior radiography. PMID:27008105
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zablotska, Lydia B., E-mail: Lydia.Zablotska@ucsf.edu; Lane, Rachel S.D.; Frost, Stanley E.
Uranium workers are chronically exposed to low levels of radon decay products (RDP) and gamma (γ) radiation. Risks of leukemia from acute and high doses of γ-radiation are well-characterized, but risks from lower doses and dose-rates and from RDP exposures are controversial. Few studies have evaluated risks of other hematologic cancers in uranium workers. The purpose of this study was to analyze radiation-related risks of hematologic cancers in the cohort of Eldorado uranium miners and processors first employed in 1932–1980 in relation to cumulative RDP exposures and γ-ray doses. The average cumulative RDP exposure was 100.2 working level months andmore » the average cumulative whole-body γ-radiation dose was 52.2 millisievert. We identified 101 deaths and 160 cases of hematologic cancers in the cohort. Overall, male workers had lower mortality and cancer incidence rates for all outcomes compared with the general Canadian male population, a likely healthy worker effect. No statistically significant association between RDP exposure or γ-ray doses, or a combination of both, and mortality or incidence of any hematologic cancer was found. We observed consistent but non-statistically significant increases in risks of chronic lymphocytic leukemia (CLL) and Hodgkin lymphoma (HL) incidence and non-Hodgkin lymphoma (NHL) mortality with increasing γ-ray doses. These findings are consistent with recent studies of increased risks of CLL and NHL incidence after γ-radiation exposure. Further research is necessary to understand risks of other hematologic cancers from low-dose exposures to γ-radiation. - Highlights: • We analyzed long-term follow-up for hematologic cancers of the Eldorado uranium workers. • Workers were exposed to a unique combination of radon decay products (RDP) and gamma (γ) ray doses. • Exposures to RDP and γ-ray doses were not associated with significantly increased risks of cancers. • Radiation risks of chronic lymphocytic leukemia (CLL) and Hodgkin lymphoma were increased. • Study findings provide additional support for radiation-related risks of CLL.« less
The effect of coenzyme Q10 in statin myopathy.
Zlatohlavek, Lukas; Vrablik, Michal; Grauova, Barbora; Motykova, Eva; Ceska, Richard
2012-01-01
Statins significantly reduce CV morbidity and mortality. Unfortunately, one of the side effects of statins is myopathy, for which statins cannot be administered in sufficient doses or administered at all. The aim of this study was to demonstrate the effect of coenzyme Q10 in patients with statin myopathy. Twenty eight patients aged 60.6±10.7 years were monitored (18 women and 10 men) and treated with different types and doses of statin. Muscle weakness and pain was monitored using a scale of one to ten, on which patients expressed the degree of their inconvenience. Examination of muscle problems was performed prior to administration of CQ10 and after 3 and 6 months of dosing. Statistical analysis was performed using Friedman test, Annova and Students t-test. Pain decreased on average by 53.8% (p<0.0001), muscle weakness by 44.4% (p<0.0001). The CQ10 levels were increased by more than 194% (from 0,903 μg/ml to 2.66 μg/ml; p<0.0001). After a six-month administration of coenzyme Q10, muscle pain and sensitivity statistically significantly decreased.
Andrade, C U B; Perazzo, F F; Maistro, E L
2008-01-01
Plants are a source of many biologically active products and nowadays they are of great interest to the pharmaceutical industry. In the present study, the mutagenic potential of the Musa paradisiaca fruit peel extract was assessed by the single-cell gel electrophoresis (SCGE) and micronucleus assays. Animals were treated orally with three different concentrations of the extract (1000, 1500, and 2000 mg/kg body weight). Peripheral blood cells of Swiss mice were collected 24 h after treatment for the SCGE assay and 48 and 72 h for the micronucleus test. The results showed that the two higher doses of the extract of M. paradisiaca induced statistically significant increases in the average numbers of DNA damage in peripheral blood leukocytes for the two higher doses and a significant increase in the mean of micronucleated polychromatic erythrocytes in the three doses tested. The polychromatic/normochromatic erythrocyte ratio scored in the treated groups was not statistically different from the negative control. The data obtained indicate that fruit peel extract from M. paradisiaca showed mutagenic effect in the peripheral blood cells of Swiss albino mice.
Clinical Pharmacokinetics and Pharmacodynamics of Atezolizumab in Metastatic Urothelial Carcinoma.
Stroh, M; Winter, H; Marchand, M; Claret, L; Eppler, S; Ruppel, J; Abidoye, O; Teng, S L; Lin, W T; Dayog, S; Bruno, R; Jin, J; Girish, S
2017-08-01
Atezolizumab, a humanized immunoglobulin G1 (IgG1) monoclonal antibody targeting human programmed death-ligand 1 (PD-L1), is US Food and Drug Administration (FDA) approved in metastatic urothelial carcinoma (MUC) and is being investigated in various malignancies. This analysis based upon 906 patients from two phase I and one phase II MUC studies, is the first report of the clinical pharmacokinetics (PK) and pharmacodynamics (PD) of atezolizumab. Atezolizumab exhibited linear PK over a dose range of 1-20 mg/kg, including the labeled 1,200 mg dose. The clearance, volume of distribution, and terminal half-life estimates from population pharmacokinetic (PopPK) analysis of 0.200 L/day, 6.91 L, and 27 days, respectively, were as expected for an IgG1. Exposure-response analyses did not identify statistically significant relationships with either objective response rate or adverse events of grades 3-5 or of special interest. None of the statistically significant covariates from PopPK (body weight, gender, antitherapeutic antibody, albumin, and tumor burden) would require dose adjustment. © 2016 American Society for Clinical Pharmacology and Therapeutics.
Thomas, Hannah Mary; Kinahan, Paul E; Samuel, James Jebaseelan E; Bowen, Stephen R
2018-02-01
To quantitatively estimate the impact of different methods for both boost volume delineation and respiratory motion compensation of [18F] FDG PET/CT images on the fidelity of planned non-uniform 'dose painting' plans to the prescribed boost dose distribution. Six locally advanced non-small cell lung cancer (NSCLC) patients were retrospectively reviewed. To assess the impact of respiratory motion, time-averaged (3D AVG), respiratory phase-gated (4D GATED) and motion-encompassing (4D MIP) PET images were used. The boost volumes were defined using manual contour (MANUAL), fixed threshold (FIXED) and gradient search algorithm (GRADIENT). The dose painting prescription of 60 Gy base dose to the planning target volume and an integral dose of 14 Gy (total 74 Gy) was discretized into seven treatment planning substructures and linearly redistributed according to the relative SUV at every voxel in the boost volume. Fifty-four dose painting plan combinations were generated and conformity was evaluated using quality index VQ0.95-1.05, which represents the sum of planned dose voxels within 5% deviation from the prescribed dose. Trends in plan quality and magnitude of achievable dose escalation were recorded. Different segmentation techniques produced statistically significant variations in maximum planned dose (P < 0.02), as well as plan quality between segmentation methods for 4D GATED and 4D MIP PET images (P < 0.05). No statistically significant differences in plan quality and maximum dose were observed between motion-compensated PET-based plans (P > 0.75). Low variability in plan quality was observed for FIXED threshold plans, while MANUAL and GRADIENT plans achieved higher dose with lower plan quality indices. The dose painting plans were more sensitive to segmentation of boost volumes than PET motion compensation in this study sample. Careful consideration of boost target delineation and motion compensation strategies should guide the design of NSCLC dose painting trials. © 2017 The Royal Australian and New Zealand College of Radiologists.
Temporal Lobe Toxicity Analysis After Proton Radiation Therapy for Skull Base Tumors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pehlivan, Berrin; Ares, Carmen, E-mail: carmen.ares@psi.ch; Lomax, Antony J.
2012-08-01
Purpose: Temporal lobe (TL) parenchyma toxicity constitutes one of the most frequent late adverse event in high-dose proton therapy (PT) for tumors of the skull base. We analyzed clinical events with dosimetric parameters in our patients treated for skull base tumors with spot-scanning PT. Methods and Materials: Between 1998 and 2005, a total of 62 patients received PT to a median dose of 71.7 Gy (relative biologic effectiveness [RBE]) (range, 63-74 Gy). The dose-volume histogram of each TL and the entire brain parenchyma (BP) were analyzed according to maximum, mean, and minimum dose as well as doses to 0.5, 1,more » 2, and 3 cc of brain volume (D{sub 0.5}, D{sub 1}, D{sub 2}, D{sub 3}) and correlated with clinical events. Generalized equivalent uniform dose (gEUD) values were calculated. Results: At a mean follow-up of 38 months (range, 14-92 months), 2 patients had developed symptomatic Grade 3 and 5 patients asymptomatic Grade 1 TL toxicity. Mean doses to a 2-cc volume of BP increased from 71 {+-} 5 Gy (RBE) for no toxicity to 74 {+-} 5 Gy (RBE) for Grade 1 and to 76 {+-} 2 Gy (RBE) for Grade 3 toxicity. TL events occurred in 6 of 7 patients (86%) at or above dose levels of {>=}64 Gy (RBE) D{sub 3}, {>=}68 Gy (RBE) D{sub 2}, {>=}72 Gy (RBE) D{sub 1}, and {>=}73 Gy (RBE) D{sub 0.5}, respectively (p = NS). No statistically significant dose/volume threshold was detected between patients experiencing no toxicity vs. Grade 1 or Grade 3. A strong trend for Grade 1 and 3 events was observed, when the gEUD was 60 Gy. Conclusions: A statistically significant normal tissue threshold dose for BP has not been successfully defined. However, our data suggest that tolerance of TL and BP to fractionated radiotherapy appears to be correlated with tissue volume included in high-dose regions. Additional follow-up time and patient accrual is likely needed to achieve clinical significance for these dose-volume parameters investigated. Our findings support the importance of establishing an organ-at-risk maximally permissible dose for BP.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozak, Kevin R.; Adams, Judith; Krejcarek, Stephanie J.
Purpose: We compared tumor and normal tissue dosimetry of proton radiation therapy with intensity-modulated radiation therapy (IMRT) for pediatric parameningeal rhabdomyosarcomas (PRMS). Methods and Materials: To quantify dosimetric differences between contemporary proton and photon treatment for pediatric PRMS, proton beam plans were compared with IMRT plans. Ten patients treated with proton radiation therapy at Massachusetts General Hospital had IMRT plans generated. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Proton and IMRT plans provided acceptable and comparable target volume coverage, with atmore » least 99% of the CTV receiving 95% of the prescribed dose in all cases. Improved dose conformality provided by proton therapy resulted in significant sparing of all examined normal tissues except for ipsilateral cochlea and mastoid; ipsilateral parotid gland sparing was of borderline statistical significance (p = 0.05). More profound sparing of contralateral structures by protons resulted in greater dose asymmetry between ipsilateral and contralateral retina, optic nerves, cochlea, and mastoids; dose asymmetry between ipsilateral and contralateral parotids was of borderline statistical significance (p = 0.05). Conclusions: For pediatric PRMS, superior normal tissue sparing is achieved with proton radiation therapy compared with IMRT. Because of enhanced conformality, proton plans also demonstrate greater normal tissue dose distribution asymmetry. Longitudinal studies assessing the impact of proton radiotherapy and IMRT on normal tissue function and growth symmetry are necessary to define the clinical consequences of these differences.« less
Koyanagawa, Naohide; Miyoshi, Hideaki; Ono, Kota; Nakamura, Akinobu; Cho, Kyu Yong; Yamamoto, Kohei; Takano, Yoshinari; Dan-Noura, Midori; Atsumi, Tatsuya
2016-08-31
The dipeptidyl peptidase-4 inhibitors vildagliptin and sitagliptin are effective in treating patients with type 2 diabetes mellitus. Patients receiving standard doses of sitagliptin plus insulin may require increased doses of sitagliptin or switching to vildagliptin to improve blood glucose control. This study compared the effects of increasing sitagliptin and switching to vildagliptin in type 2 diabetes patients receiving standard doses of sitagliptin plus insulin. This prospective, randomized, parallel-group comparison trial enrolled 33 type 2 diabetes patients receiving 50 mg sitagliptin once daily plus insulin. Seventeen patients were randomized to 50 mg vildagliptin twice daily, and 16 to 100 mg sitagliptin once daily, and evaluated by continuous glucose monitoring at baseline and after 8 weeks. The primary end-point was the change in mean amplitude of glycemic excursions (MAGE). MAGE decreased from baseline in both the vildagliptin (-13.4 ± 35.7 mg/dL) and sitagliptin (-8.4 ± 24.3 mg/dL) groups, but neither within- nor between-group changes were statistically significant. Similarly, the areas under the curve for blood glucose levels ≥180 mg/dL and <70 mg/dL tended to improve in both groups, but these differences were not statistically significant. In contrast, HbA1c was significantly reduced only in the vildagliptin group, from 7.1 ± 0.6% at baseline to 6.8 ± 0.6% at 8 weeks (p=0.006). Increasing sitagliptin dose and switching to vildagliptin had limited effects in improving MAGE in type 2 diabetic patients treated with standard doses of sitagliptin.
Population Pharmacokinetics of Intranasal Scopolamine
NASA Technical Reports Server (NTRS)
Wu, L.; Chow, D. S. L.; Putcha, L.
2013-01-01
Introduction: An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS).The bioavailability and pharmacokinetics (PK) was evaluated using data collected in Phase II IND protocols. We reported earlier statistically significant gender differences in PK parameters of INSCOP at a dose level of 0.4 mg. To identify covariates that influence PK parameters of INSCOP, we examined population covariates of INSCOP PK model for 0.4 mg dose. Methods: Plasma scopolamine concentrations versus time data were collected from 20 normal healthy human subjects (11 male/9 female) after a 0.4 mg dose. Phoenix NLME was employed for PK analysis of these data using gender, body weight and age as covariates for model selection. Model selection was based on a likelihood ratio test on the difference of criteria (-2LL). Statistical significance for base model building and individual covariate analysis was set at P less than 0.05{delta(-2LL)=3.84}. Results: A one-compartment pharmacokinetic model with first-order elimination best described INSCOP concentration ]time profiles. Inclusion of gender, body weight and age as covariates individually significantly reduced -2LL by the cut-off value of 3.84(P less than 0.05) when tested against the base model. After the forward stepwise selection and backward elimination steps, gender was selected to add to the final model which had significant influence on absorption rate constant (ka) and the volume of distribution (V) of INSCOP. Conclusion: A population pharmacokinetic model for INSCOP has been identified and gender was a significant contributing covariate for the final model. The volume of distribution and Ka were significantly higher in males than in females which confirm gender-dependent pharmacokinetics of scopolamine after administration of a 0.4 mg dose.
NASA Astrophysics Data System (ADS)
Mahmud, M. H.; Nordin, A. J.; Saad, F. F. Ahmad; Fattah Azman, A. Z.
2014-11-01
This study aims to estimate the radiation effective dose resulting from whole body fluorine-18 flourodeoxyglucose Positron Emission Tomography (18F-FDG PET) scanning as compared to conservative Computed Tomography (CT) techniques in evaluating oncology patients. We reviewed 19 oncology patients who underwent 18F-FDG PET/CT at our centre for cancer staging. Internal and external doses were estimated using radioactivity of injected FDG and volume CT Dose Index (CTDIvol), respectively with employment of the published and modified dose coefficients. The median differences of dose among the conservative CT and PET protocols were determined using Kruskal Wallis test with p < 0.05 considered as significant. The median (interquartile range, IQR) effective doses of non-contrasted CT, contrasted CT and PET scanning protocols were 7.50 (9.35) mSv, 9.76 (3.67) mSv and 6.30 (1.20) mSv, respectively, resulting in the total dose of 21.46 (8.58) mSv. Statistically significant difference was observed in the median effective dose between the three protocols (p < 0.01). The effective doses of whole body 18F-FDG PET technique may be effective the lowest amongst the conventional CT imaging techniques.
Caniggia, A; Marchetti, M; Gennari, C; Vattimo, A; Nicolis, F B
1977-03-01
The urinary elimination of calcium, other electrolytes, and hydroxyproline and the oral absorption of 47Ca have been evaluated in three groups of 8 patients before and during a 15-day treatment with prednisone at daily doses of 25 and 50 mg and with oxazacort, a new glucocorticoid, at a daily dose of 50 mg. The results obtained demonstrate that oxazacort in short-term teatment with a high dose has no significant effect on the urinary elimination of calcium and hydroxypyroline in experimental conditions in which prednisone produces statistically significant and clinically relevant increase, both when given at the same dose and when given at half that dose. On the other hand, the oral absorption of 47Ca is decreased by oxazacort, but less than by prednisone at the same dose. As the antirheumatic activity of oxazacort appears to be only slightly lower than that of prednisone (activity ratio of about 0.84: 1), these findings may have interesting therapeutic implications.
Strojan, Primož; Vermorken, Jan B; Beitler, Jonathan J; Saba, Nabil F; Haigentz, Missak; Bossi, Paolo; Worden, Francis P; Langendijk, Johannes A; Eisbruch, Avraham; Mendenhall, William M; Lee, Anne W M; Harrison, Louis B; Bradford, Carol R; Smee, Robert; Silver, Carl E; Rinaldo, Alessandra; Ferlito, Alfio
2016-04-01
The optimal cumulative dose and timing of cisplatin administration in various concurrent chemoradiotherapy protocols for nonmetastatic head and neck squamous cell carcinoma (HNSCC) has not been determined. The absolute survival benefit at 5 years of concurrent chemoradiotherapy protocols versus radiotherapy alone observed in prospective randomized trials reporting on the use of cisplatin monochemotherapy for nonnasopharyngeal HNSCC was extracted. In the case of nonrandomized studies, the outcome results at 2 years were compared between groups of patients receiving different cumulative cisplatin doses. Eleven randomized trials and 7 nonrandomized studies were identified. In 6 definitive radiotherapy phase III trials, a statistically significant association (p = .027) between cumulative cisplatin dose, independent of the schedule, and overall survival benefit was observed for higher doses. Results support the conclusion that the cumulative dose of cisplatin in concurrent chemoradiation protocols for HNSCC has a significant positive correlation with survival. © 2015 Wiley Periodicals, Inc. Head Neck 38: E2151-E2158, 2016. © 2015 Wiley Periodicals, Inc.
Objective Analysis of Poly-L-Lactic Acid Injection Efficacy in Different Settings.
Byun, Sang-Young; Seo, Koo-Il; Shin, Jung-Won; Kwon, Soon-Hyo; Park, Mi-Sook; Lee, Joshua; Park, Kyoung-Chan; Na, Jung-Im; Huh, Chang-Hun
2015-12-01
Poly-L-lactic acid (PLLA) filler is known to have continuous volume effect. The objective of this study is to analyze objective volume effect of PLLA in different settings of injection schedule on the cheek. A split-face, evaluator-blind randomized study in 24 volunteers was conducted. One side was injected 3 times with 4 cc dose and the other side was injected 2 times with 6 cc dose per visit. Facial volume loss scale (FVLS) and Vectra were evaluated. Measured average FVLS showed statistically significant improvement both in 3 and 2 times injection sides and maintained efficacy until 12 months. Vectra showed volume difference (cc) between before and after injection. In 3 times injection side, it was increased 2.12 (after 1 month) to 3.17 (after 12 months). In 2 times injection side, it was increased 2.26 (after 1 month) to 3.19 (after 12 months). Gradual volume improvement over 12 months was statistically significant in both sides. There was no statistically significant difference between 3 and 2 times injection in FVLS and Vectra. There was no severe adverse event. Poly-L-lactic acid has continuous volume effect and there was no significant difference by injection times at the same total injection volume.
Carver, Robert L; Sprunger, Conrad P; Hogstrom, Kenneth R; Popple, Richard A; Antolak, John A
2016-05-08
The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and < 0.2% statistical uncertainties. The accuracy of the dose calculations using moderate smoothing and no smooth-ing were evaluated. Dose differences (eMC-calculated less measured dose) were evaluated in terms of absolute dose difference, where 100% equals the given dose, as well as distance to agreement (DTA). Dose calculations were also evaluated for calculation speed. Results from the eMC for the retromolar trigone phantom using 1% statistical uncertainty without smoothing showed calculated dose at 89% (41/46) of the measured TLD-dose points was within 3% dose difference or 3 mm DTA of the measured value. The average dose difference was -0.21%, and the net standard deviation was 2.32%. Differences as large as 3.7% occurred immediately distal to the mandible bone. Results for the nose phantom, using 1% statistical uncertainty without smoothing, showed calculated dose at 93% (53/57) of the measured TLD-dose points within 3% dose difference or 3 mm DTA. The average dose difference was 1.08%, and the net standard deviation was 3.17%. Differences as large as 10% occurred lateral to the nasal air cavities. Including smoothing had insignificant effects on the accuracy of the retromolar trigone phantom calculations, but reduced the accuracy of the nose phantom calculations in the high-gradient dose areas. Dose calculation times with 1% statistical uncertainty for the retromolar trigone and nose treatment plans were 30 s and 24 s, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.
Intrathecal Baclofen Dosing Regimens: A Retrospective Chart Review.
Clearfield, Jacob S; Nelson, Mary Elizabeth S; McGuire, John; Rein, Lisa E; Tarima, Sergey
2016-08-01
To examine dosing patterns in patients receiving baclofen via intrathecal baclofen pumps to assess for common patterns by diagnosis, ambulation ability, and affected limbs distribution. This trial study included 25 patients with baclofen pumps selected from the 356 patients enrolled in our center's baclofen pump program. Selection was done by splitting all patients into diagnostic categories of stroke, multiple sclerosis, traumatic/anoxic brain injury, cerebral palsy, and spinal cord injury, and then, five patients were randomly selected from each diagnosis.A systematic chart review was then conducted for each patient from Jan 1, 2008, through September 16, 2013, to look at factors including mean daily dose at end of study, and among those implanted during the study mean initial stable dose and time to initial stable dose. Analysis of mean daily dose across diagnoses found significant differences, with brain injury, cerebral palsy, and spinal cord injury patients having higher doses while multiple sclerosis and stroke patients required lower doses. Nonambulatory patients strongly trended to have higher daily doses than ambulatory patients. Similar trends of mean initial stable dose being higher in a similar pattern as that of end mean daily dose were seen according to diagnoses and ambulatory status, although statistical significance could not be achieved with the small sample size. Significant differences in dosing were found between diagnoses and trended to differ by ambulatory status at the end of the study, and similar trends could be observed in achieving initial stable dose. © 2015 International Neuromodulation Society.
Determination of quality parameters from statistical analysis of routine TLD dosimetry data.
German, U; Weinstein, M; Pelled, O
2006-01-01
Following the as low as reasonably achievable (ALARA) practice, there is a need to measure very low doses, of the same order of magnitude as the natural background, and the limits of detection of the dosimetry systems. The different contributions of the background signals to the total zero dose reading of thermoluminescence dosemeter (TLD) cards were analysed by using the common basic definitions of statistical indicators: the critical level (L(C)), the detection limit (L(D)) and the determination limit (L(Q)). These key statistical parameters for the system operated at NRC-Negev were quantified, based on the history of readings of the calibration cards in use. The electronic noise seems to play a minor role, but the reading of the Teflon coating (without the presence of a TLD crystal) gave a significant contribution.
Chen, Jiayun; Fu, Guishan; Li, Minghui; Song, Yixin; Dai, Jianrong; Miao, Junjie; Liu, Zhiqiang; Li, Yexiong
2017-12-14
The purpose of this paper was to evaluate the impact of leaf treatment of multileaf collimator (MLC) in plan quality of intensity-modulated radiotherapy (IMRT) of patients with advanced lung cancer. Five MLCs with different leaf transmissions (0.01%, 0.5%, 1.2%, 1.8%, and 3%) were configured for an accelerator in a treatment planning system. Correspondingly, 5 treatment plans with the same optimization setting were created and evaluated quantitatively for each patient (11 patients total) who was diagnosed with advanced lung cancer. All of the 5 plans for each patient met the dose requirement for the planning treatment volumes (PTVs) and had similar target dose homogeneity and conformity. On average, the doses to selected organs were as follows: (1) V 5 , V 20 , and the mean dose of total lung; (2) the maximum and mean dose to spinal cord planning organ-at-risk volume (PRV); and (3) V 30 and V 40 of heart, decreased slightly when MLC transmission was decreased, but with no statistical differences. There is a clear grouping of plans having total quality score (S D ) value, which is used to evaluate plan quality: (1) more than 1 (patient nos. 1 to 3, 5, and 8), and more than 2.5 (patient no. 6); (2) less than 1 (patient nos. 7 and 10); (3) around 1 (patient nos. 4, 9, and 11). As MLC transmission increased, overall S D values increased as well and plan dose requirement was harder to meet. The clinical requirements were violated increasingly as MLC transmission became large. Total S D with and without normal tissue (NT) showed similar results, with no statistically significant differences. Therefore, decrease of MLC transmission did have minimum impact on plan, and it improved target coverage and reduced normal tissue radiation slightly, with no statistical significance. Plan quality could not be significantly improved by MLC transmission reduction. However, lower MLC transmission may have advantages on lung sparing to low- and intermediate-dose exposure. Besides conventional fraction, hyperfraction, or stereotactic body radiotherapy (SBRT), the reduction on lung sparing is still essential because it is highly relevant to radiation pneumonitis (RP). It has potential to diminish incidence of RP and improve patient's quality of life after irradiation with lowered MLC transmission. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Li, Zhen; Li, Qiong; Shen, Yaqi; Li, Anqin; Li, Haojie; Liang, Lili; Hu, Yao; Hu, Xuemei; Hu, Daoyu
2016-09-01
The aim of this study was to investigate the effect of using low tube voltage, low-concentration contrast media and adaptive statistical iterative reconstruction (ASIR) for reducing the radiation and iodine contrast doses in adrenal and nephrogenic hypertension patients. A total of 148 hypertension patients who were suspected for adrenal lesions or renal artery stenoses were assigned to two groups and. Group A (n=74) underwent a low tube voltage, low molecular weight dextran enhanced multi-detector row spiral CT (MDCT) (80 kVp, 270 mg I/mL contrast agent), and the raw data were reconstructed with standard filtered back projection (FBP) and ASIR at four different levels of blending (20%, 40%, 60% and 80%, respectively). The control group (Group B, n=74) underwent conventional MDCT (120 kVp, 370 mg I/mL contrast agent), and the data were reconstructed with FBP. The CT values, standard deviation (SD), signal-noise-ratio (SNR) and contrast-noise-ratio (CNR) were measured in the renal vessels, normal adrenal tissue, adrenal neoplasms and subcutaneous fat. The volume CT dose index (CTDIvol ) and dose length product (DLP) were recorded, and an effective dose (ED) was obtained. Two-tailed independent t-tests, paired Chi-square tests and Kappa consistency tests were used for statistical analysis of the data. The CTDIvol , DLP and total iodine dose in group A were decreased by 47.8%, 49.0% and 26.07%, respectively, compared to group B (P<.001). In the qualitative quality analysis, the radiologists rated the 60% ASIR the highest. The mean value of noise (SD) was significantly lower in the 40%, 60% and 80% ASIR-A groups compared with FBP-B for all comparisons. Compared to FBP-B, CNR was significantly higher, with 40%, 60% and 80% ASIR in renal artery stems (P<.05). Compared with FBP-B, a significant increase in the SNR of 40%, 60%, or 80% ASIR was observed in all cases (P<.05). Compared with conventional protocols, the use of low tube voltage, low-concentration contrast media and 60% ASIR provides similar enhancement and image quality with a reduced radiation dose and contrast iodine dose. © 2016 John Wiley & Sons Ltd.
Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C
2013-06-01
Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.
Impact of Momordica charantia extract on kidney function and structure in mice.
Mardani, Saeed; Nasri, Hamid; Hajian, Shabnam; Ahmadi, Ali; Kazemi, Reyhane; Rafieian-Kopaei, Mahmoud
2014-01-01
Bitter Melon (BM) is known for its hypoglycemic effect and is commonly used in populations. This study examined the effects and safety of bitter melon fruit in laboratory mice. In this experimental study 70 male mice (25-30 gr) were randomly divided into 7 groups. The mice were injected intraperitoneally with single doses of 0, 100, 500, 1000, 2000 and 4000 mg/kg and multiple doses 500 mg/kg daily for 7 days. The mice were then observed for 72 hours before sacrificing. Immediately kidneys were taken out for histological examinations. Tubular cell vacuolization and flattening as well as hyaline casts, debris and dilatation of tubular lumen were the morphologic lesions which were assessed with scores from 0 to 4, while zero score addressed normal renal tissue. Serum samples were assayed for kidney function (creatinine; Cr and Blood Urea Nitrogen; BUN). Blood and bitter melon antioxidant activities were measured, too. Data were analyzed with Stata software (Stata Corp. 2011. Stata Statistical Software: Release 12. College Station, TX: Stata Corp LP)using ANOVA and Bonferroni tests. All single dose groups showed normal behavior after the dosing and no statistical changes were observed in blood parameters (p>0.05). Histological examinations revealed normal organ structures, however, the group treated for 7 days showed statistically a significant change in BUN (p=0.002) and a borderline significance in Cr (p=0.051). Administration of up to 4000 mg/kg did not have any effect on the mice kidney function and histology, however chronic administration were nephrotoxic. More studies with different dosage regimens are suggested.
Herle, Pradyumna; Shukla, Lipi; Morrison, Wayne A; Shayan, Ramin
2015-03-01
There is a general consensus among reconstructive surgeons that preoperative radiotherapy is associated with a higher risk of flap failure and complications in head and neck surgery. Opinion is also divided regarding the effects of radiation dose on free flap outcomes and timing of preoperative radiation to minimize adverse outcomes. Our meta-analysis will attempt to address these issues. A systematic review of the literature was conducted in concordance to PRISMA protocol. Data were combined using STATA 12 and Open Meta-Analyst software programmes. Twenty-four studies were included comparing 2842 flaps performed in irradiated fields and 3491 flaps performed in non-irradiated fields. Meta-analysis yielded statistically significant risk ratios for flap failure (RR 1.48, P = 0.004), complications (RR 1.84, P < 0.001), reoperation (RR 2.06, P < 0.001) and fistula (RR 2.05, P < 0.001). Mean radiation dose demonstrated a trend towards increased risk of flap failure, but this was not statistically significant. On subgroup analysis, flaps with >60 Gy radiation had a non-statistically significant higher risk of flap failure (RR 1.61, P = 0.145). Preoperative radiation is associated with a statistically significant increased risk of flap complications, failure and fistula. Preoperative radiation in excess of 60 Gy after radiotherapy represents a potential risk factor for increased flap loss and should be avoided where possible. © 2014 Royal Australasian College of Surgeons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widesott, Lamberto, E-mail: widesott@yahoo.it; Pierelli, Alessio; Fiorino, Claudio
2011-08-01
Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normalmore » tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.« less
Jagadeesan, Soumya; Sobhanakumari, K; Sadanandan, Sadeep Melethil; Ravindran, Sheeba; Divakaran, Manjula Velikkakathu; Skaria, Lissy; Kurien, George
2013-01-01
Toxic epidermal necrolysis (TEN) is a severe adverse drug reaction associated with high mortality. Though different modalities of treatment are advocated, there is no consensus regarding specific therapy. Corticosteroids have shown conflicting results and for high dose intravenous immunoglobulins (IVIG), cost is a limiting factor. To find out the effectiveness of combination therapy with low-dose IVIG and steroids versus steroids alone in our TEN patients. After obtaining Ethical Committee approval, 36 consecutive TEN patients (2008-2012) were alternately allocated to 2 groups - Group A was given combination of low-dose IVIG (0.2-0.5 g/kg) and rapidly tapering course of steroids (intravenous dexamethasone 0.1- 0.3 mg/kg/day tapered in 1-2 weeks) while Group B was given same dose of steroids alone. Outcome parameters assessed were time taken for arrest of disease progression, time taken for re-epithelization, duration of hospital stay and mortality rates. Both groups had 18 patients. Baseline characteristics like age, sex ratio, SCORTEN, body surface area involvement and treatment interval were comparable. Time for arrest of disease progression and for re-epithelization was significantly lowered in Group A (P = 0.0001, P = 0.0009 respectively). Though duration of hospital stay and deaths were less in Group A, difference was not statistically significant. SCORTEN based standardized mortality ratio (SMR) analysis revealed that combination therapy reduced the probability of dying by 82% (SMR = 0.18 ± 0.36) and steroids by 37% (SMR = 0.63 ± 0.71). Difference in SMR was statistically significant (P = 0.00001). No significant side effects due to either modality were found in any of the patients. Combination therapy with low-dose IVIG and steroids is more effective in terms of reduced mortality and faster disease resolution when compared to steroids alone in TEN.
Babalis, George A; Yiannakopoulos, Christos K; Karliaftis, Konstantinos; Antonogiannakis, Emmanuel
2004-03-01
The efficacy of a minimum dose of methylprednisolone for the prevention of posttraumatic hypoxaemia and fat embolism syndrome (FES) was prospectively studied in 87 patients with isolated, closed or grade I open, femoral and tibial fractures. On admission, the patients were randomly allocated either to a control group given placebo (40 patients) or to a methylprednisolone-treated group (47 patients). A total dose of 6 mg/kg BW methylprednisolone (SoluMedrol, Upjohn) was administered intravenously, divided in six equal doses at 8 h intervals. Six patients (12.8%) in the control group and one patient (2.5%) in the trial group developed FES (P = 0.079) but the difference is not statistically significant. Twenty-four hours after admission, the steroid-treated patients displayed statistically significant higher p(O2) values compared to the control group (P = 0.035) and this difference persisted on the second and the third post-admission day as well (P = 0.008). No corticosteroid-related side-effects were noticed in any of the patients during hospitalisation. Our results support the prophylactic administration of methylprednisolone in small dosage to prevent posttraumatic hypoxaemia and probably FES in patients with isolated lower limb long bone fractures, especially when early fracture stabilisation is not possible.
Zhou, Yunfeng; Wang, Juan; Dassarath, Meera; Wang, Minhong; Zhang, Qiang; Xiong, Yuwei; Yuan, Quan
2015-01-01
To prospectively compare the new computed tomographic angiography (CTA) protocol (NCP) using 80-kV and dual-phase scanning with the routine CTA protocol (RCP) using 120-kV and single-phase scanning in patients with peripheral arterial disease. A total of 60 patients were randomized to undergo the NCP (30 patients) or RCP (30 patients) scan. We compared the arterial attenuation values, overriding of the contrast bolus, signal-to-noise ratio, and radiation dose between 2 groups. The occurrence rate of contrast bolus overriding was not statistically significant (P = 0.69). The average arterial attenuation value in the NCP group was significantly higher (P < 0.05) than that in the RCP group. The radiation dose in the RCP group was significantly higher (P < 0.001) than that in the NCP group. The mean signal-to-noise ratio in the NCP group was significantly lower (P < 0.001). Sixty-four-slice CTA with the NCP can significantly reduce the radiation dose and improve the arterial enhancement and calf arteries imaging.
Son, Seok Hyun; Kang, Young Nam; Ryu, Mi-Ryeong
2012-01-01
The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p < 0.001), and this showed a statistically significant difference among the kinds of CT images: the effect of metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Son, Seok Hyun; Kang, Young Nam; Ryu, Mi-Ryeong, E-mail: mrryu@catholic.ac.kr
2012-04-01
The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapymore » Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p < 0.001), and this showed a statistically significant difference among the kinds of CT images: the effect of metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk.« less
The impact of CYP2C8 polymorphism and grapefruit juice on the pharmacokinetics of repaglinide
Bidstrup, Tanja Busk; Damkier, Per; Olsen, Anette Kristensen; Ekblom, Marianne; Karlsson, Anders; Brøsen, Kim
2006-01-01
Aims The primary aim of the study was to investigate the possible effect of the CYP2C8 3 allele and of grapefruit juice on the pharmacokinetics of repaglinide. Furthermore, the impact of a single dose of grapefruit juice on the pharmacokinetics of repaglinide in relation to dose. Methods Thirty-six healthy male subjects, genotyped for CYP2C8 3 (11 genotyped as CYP2C8 1/ 3, one as CYP2C8 3/ 3 and 24 as CYP2C8 1/ 1), participated in a randomized, cross-over trial. In the two phases, the subjects drank 300 mL water or 300 mL grapefruit juice, in randomized order, 2 h before administration of a single dose of either 0.25 mg or 2 mg repaglinide. Results Neither the mean AUC0−∞ (geometric mean ratio: 1.01; 95% CI: 0.93–1.1, P = 0.88) nor the mean Cmax (geometric mean ratio: 1.05; 95% CI: 0.94–1.2, P = 0.35) of repaglinide were statistically significantly different in the group carrying the CYP2C8 3 mutant allele compared with wild-types. Grapefruit juice caused a 19% decrease in the geometric mean ratio of the 3-hydroxyquinidine to quinidine ratio (difference: 0.81; 95% CI: 0.75–0.87, P < 0.0001), which was used as an index of CYP3A4 activity, and an increase in the mean AUC0−∞ of repaglinide (geometric mean ratio: 1.13; 95% CI: 1.04–1.2, P = 0.0048), but had no statistically significant effect on the t1/2. There was no statistically significant difference in blood glucose concentration in subjects who had or had not ingested grapefruit juice. The effect was more pronounced at the low dose of repaglinide (0.25 mg) than at the therapeutic dose of 2 mg. Conclusions The pharmacokinetics of repaglinide in subjects carrying the CYP2C8*3 mutant allele did not differ significantly from those in the wild-types. Grapefruit juice increased the bioavailability of repaglinide, suggesting significant intestinal elimination of the drug which was assumed to be primarily mediated by CYP3A4 in the gut. PMID:16390351
The impact of CYP2C8 polymorphism and grapefruit juice on the pharmacokinetics of repaglinide.
Bidstrup, Tanja Busk; Damkier, Per; Olsen, Anette Kristensen; Ekblom, Marianne; Karlsson, Anders; Brøsen, Kim
2006-01-01
The primary aim of the study was to investigate the possible effect of the CYP2C8*3 allele and of grapefruit juice on the pharmacokinetics of repaglinide. Furthermore, the impact of a single dose of grapefruit juice on the pharmacokinetics of repaglinide in relation to dose. Thirty-six healthy male subjects, genotyped for CYP2C8*3 (11 genotyped as CYP2C8*1/*3, one as CYP2C8*3/*3 and 24 as CYP2C8*1/*1), participated in a randomized, cross-over trial. In the two phases, the subjects drank 300 mL water or 300 mL grapefruit juice, in randomized order, 2 h before administration of a single dose of either 0.25 mg or 2 mg repaglinide. Neither the mean AUC(0-infinity) (geometric mean ratio: 1.01; 95% CI: 0.93-1.1, P = 0.88) nor the mean C(max) (geometric mean ratio: 1.05; 95% CI: 0.94-1.2, P = 0.35) of repaglinide were statistically significantly different in the group carrying the CYP2C8*3 mutant allele compared with wild-types. Grapefruit juice caused a 19% decrease in the geometric mean ratio of the 3-hydroxyquinidine to quinidine ratio (difference: 0.81; 95% CI: 0.75-0.87, P < 0.0001), which was used as an index of CYP3A4 activity, and an increase in the mean AUC(0-infinity) of repaglinide (geometric mean ratio: 1.13; 95% CI: 1.04-1.2, P = 0.0048), but had no statistically significant effect on the t(1/2). There was no statistically significant difference in blood glucose concentration in subjects who had or had not ingested grapefruit juice. The effect was more pronounced at the low dose of repaglinide (0.25 mg) than at the therapeutic dose of 2 mg. The pharmacokinetics of repaglinide in subjects carrying the CYP2C8*3 mutant allele did not differ significantly from those in the wild-types. Grapefruit juice increased the bioavailability of repaglinide, suggesting significant intestinal elimination of the drug which was assumed to be primarily mediated by CYP3A4 in the gut.
Kim, Woo Sub; Choi, Chang Kweon; Yoon, Sang Ho
2014-01-01
Objective To evaluate the effect of caffeine on balance control of hemiparetic stroke patients, we investigated the difference in postural stability before and after drinking coffee by observing changes in stability index (SI) from posturography. Methods Thirty patients with history of stroke and 15 age-matched healthy subjects participated in this study. Effect of group factor (of the control and stroke groups) and treatment factor (pre- and post-drinking of coffee) on SI were tested in three conditions: with eyes opened, with eyes closed, and with a pillow support. The effects of these factors on visual deprivation and somatosensory change of subjects were also tested. Results Under all conditions, SI was higher in the stroke group than in the control group. Under eyes-open condition, the treatment factor was not statistically significant. Under eyes-closed condition, the interaction between group and treatment factor was statistically significant. After the subjects drank coffee, SI in the control group was increased. However, SI in the stroke group was decreased. Under pillow-supported condition, the interaction between group and treatment factor appeared marginally significant. For visual deprivation effect, the interaction between treatment and group factor was statistically significant. After caffeine consumption, the visual deprivation effect was increased in control group but decreased in the stroke group. For somatosensory change effect, the interaction between group and treatment factor was not statistically significant. Conclusion Postural stability of hemiparetic stroke patients related to somatosensory information was improved after intake of usual dose of caffeine. PMID:25566476
Effect of oral dosing vehicles on the developmental toxicity of flubendazole in rats.
Yoshimura, Haruo
2003-01-01
Flubendazole was suspended in deionized water or olive oil and administered by gavage once daily to pregnant rats on Days 8-15 of pregnancy to examine if the embryolethal and teratogenic doses were affected by the vehicles used. Flubendazole in olive oil caused a statistically significant increase in embryolethality at doses of 7.83 mg/kg per day and higher, with complete resorption in all dams at 31.33 mg/kg per day. When flubendazole was suspended in deionized water, a significant increase in embryolethality occurred only at a maternal dose of 125.32 mg/kg per day. The proportion of litters with anomalous fetuses was significantly increased at doses of 31.33 mg/kg per day and above when flubendazole was administered in deionized water, but increased at doses at four times lower when flubendazole was administered as in olive oil. Administered as a single dose in olive oil on any one of Days 6-12 of pregnancy, a flubendazole dose of 31.33 mg/kg caused significant increases in embryolethality and decreased fetal body weights on Days 7-9, with an 82.7% incidence of embryolethality on Day 8, with complete resorption in 5 of the 8 dams. The critical periods for teratogenic effects were between Days 8 and 11 of pregnancy, with Day 9 being the most critical. Fetuses with gross, skeletal, or internal anomalies were seen in dams given a single dose of as low as 7.83 mg/kg.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greco, Carlo; Zelefsky, Michael J., E-mail: zelefskm@mskcc.or; Lovelock, Michael
2011-03-15
Purpose: To report tumor local control after treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) to extracranial metastatic sites. Methods and Materials: A total of 126 metastases in 103 patients were treated with SD-IGRT to prescription doses of 18-24 Gy (median, 24 Gy) between 2004 and 2007. Results: The overall actuarial local relapse-free survival (LRFS) rate was 64% at a median follow-up of 18 months (range, 2-45 months). The median time to failure was 9.6 months (range, 1-23 months). On univariate analysis, LRFS was significantly correlated with prescription dose (p = 0.029). Stratification by dose into high (23 to 24 Gy),more » intermediate (21 to 22 Gy), and low (18 to 20 Gy) dose levels revealed highly significant differences in LRFS between high (82%) and low doses (25%) (p < 0.0001). Overall, histology had no significant effect on LRFS (p = 0.16). Renal cell histology displayed a profound dose-response effect, with 80% LRFS at the high dose level (23 to 24 Gy) vs. 37% with low doses ({<=}22 Gy) (p = 0.04). However, for patients who received the high dose level, histology was not a statistically significant predictor of LRFS (p = 0.90). Target organ (bone vs. lymph node vs. soft tissues) (p = 0.5) and planning target volume size (p = 0.55) were not found to be associated with long-term LRFS probability. Multivariate Cox regression analysis confirmed prescription dose to be a significant predictor of LRFS (p = 0.003). Conclusion: High-dose SD-IGRT is a noninvasive procedure resulting in high probability of local tumor control. Single-dose IGRT may be effectively used to locally control metastatic deposits regardless of histology and target organ, provided sufficiently high doses (> 22 Gy) of radiation are delivered.« less
Ippolito, Davide; Fior, Davide; Franzesi, Cammillo Talei; Riva, Luca; Casiraghi, Alessandra; Sironi, Sandro
2017-12-01
Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose 4 ; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.
Pneumococcal Conjugate Vaccine and Pneumonia Prevention in Children with Congenital Heart Disease.
Solórzano-Santos, Fortino; Espinoza-García, Lilia; Aguilar-Martínez, Glorinella; Beirana-Palencia, Luisa; Echániz-Avilés, Gabriela; Miranda-Novales, Guadalupe
2017-01-01
A successful strategy to prevent Streptococcus pneumoniae infections is the administration of pneumococcal conjugate vaccines (PCVs). To analyze the effectiveness of the 7- and 13-valent PCV for the prevention of all-cause pneumonia. A retrospective cohort of children younger than 5 years of age, with congenital heart disease (CHD) and different vaccination schedules, was analyzed. History of vaccination was confirmed with verifiable records. The outcome measure was all-cause pneumonia or bronchopneumonia. Protocol was approved by the Institutional Review Board. For comparisons, we used inferential statistics with Chi-square and Fisher's exact test; a p ≤ 0.5 was considered statistically significant. Relative and absolute risks reduction and number needed to treat were also calculated. A total of 348 patients were included: 196 with two or more doses of PCV (considered the vaccinated group), and 152 in the unvaccinated group. There was a statistically significant difference for pneumonia events (p < 0.001) between the vaccinated (26/196) and unvaccinated (51/152) groups. The relative risk reduction was 60.5%, and the absolute risk reduction, 20.3%. There were no differences between patients who received two, three or four doses. The number needed to vaccinate to prevent one event of pneumonia was 5 children. At least two doses of PCV in children with CHD reduced the risk of all-cause pneumonia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kost, S; Yu, N; Lin, S
2016-06-15
Purpose: To compare mean lung dose (MLD) estimates from 99mTc macroaggregated albumin (MAA) SPECT/CT using two published methodologies for patients treated with {sup 90}Y radioembolization for liver cancer. Methods: MLD was estimated retrospectively using two methodologies for 40 patients from SPECT/CT images of 99mTc-MAA administered prior to radioembolization. In these two methods, lung shunt fractions (LSFs) were calculated as the ratio of scanned lung activity to the activity in the entire scan volume or to the sum of activity in the lung and liver respectively. Misregistration of liver activity into the lungs during SPECT acquisition was overcome by excluding lungmore » counts within either 2 or 1.5 cm of the diaphragm apex respectively. Patient lung density was assumed to be 0.3 g/cm{sup 3} or derived from CT densitovolumetry respectively. Results from both approaches were compared to MLD determined by planar scintigraphy (PS). The effect of patient size on the difference between MLD from PS and SPECT/CT was also investigated. Results: Lung density from CT densitovolumetry is not different from the reference density (p = 0.68). The second method resulted in lung dose of an average 1.5 times larger lung dose compared to the first method; however the difference between the means of the two estimates was not significant (p = 0.07). Lung dose from both methods were statistically different from those estimated from 2D PS (p < 0.001). There was no correlation between patient size and the difference between MLD from PS and both SPECT/CT methods (r < 0.22, p > 0.17). Conclusion: There is no statistically significant difference between MLD estimated from the two techniques. Both methods are statistically different from conventional PS, with PS overestimating dose by a factor of three or larger. The difference between lung doses estimated from 2D planar or 3D SPECT/CT is not dependent on patient size.« less
SU-E-T-503: IMRT Optimization Using Monte Carlo Dose Engine: The Effect of Statistical Uncertainty.
Tian, Z; Jia, X; Graves, Y; Uribe-Sanchez, A; Jiang, S
2012-06-01
With the development of ultra-fast GPU-based Monte Carlo (MC) dose engine, it becomes clinically realistic to compute the dose-deposition coefficients (DDC) for IMRT optimization using MC simulation. However, it is still time-consuming if we want to compute DDC with small statistical uncertainty. This work studies the effects of the statistical error in DDC matrix on IMRT optimization. The MC-computed DDC matrices are simulated here by adding statistical uncertainties at a desired level to the ones generated with a finite-size pencil beam algorithm. A statistical uncertainty model for MC dose calculation is employed. We adopt a penalty-based quadratic optimization model and gradient descent method to optimize fluence map and then recalculate the corresponding actual dose distribution using the noise-free DDC matrix. The impacts of DDC noise are assessed in terms of the deviation of the resulted dose distributions. We have also used a stochastic perturbation theory to theoretically estimate the statistical errors of dose distributions on a simplified optimization model. A head-and-neck case is used to investigate the perturbation to IMRT plan due to MC's statistical uncertainty. The relative errors of the final dose distributions of the optimized IMRT are found to be much smaller than those in the DDC matrix, which is consistent with our theoretical estimation. When history number is decreased from 108 to 106, the dose-volume-histograms are still very similar to the error-free DVHs while the error in DDC is about 3.8%. The results illustrate that the statistical errors in the DDC matrix have a relatively small effect on IMRT optimization in dose domain. This indicates we can use relatively small number of histories to obtain the DDC matrix with MC simulation within a reasonable amount of time, without considerably compromising the accuracy of the optimized treatment plan. This work is supported by Varian Medical Systems through a Master Research Agreement. © 2012 American Association of Physicists in Medicine.
Siebers, Jeffrey V
2008-04-04
Monte Carlo (MC) is rarely used for IMRT plan optimization outside of research centres due to the extensive computational resources or long computation times required to complete the process. Time can be reduced by degrading the statistical precision of the MC dose calculation used within the optimization loop. However, this eventually introduces optimization convergence errors (OCEs). This study determines the statistical noise levels tolerated during MC-IMRT optimization under the condition that the optimized plan has OCEs <100 cGy (1.5% of the prescription dose) for MC-optimized IMRT treatment plans.Seven-field prostate IMRT treatment plans for 10 prostate patients are used in this study. Pre-optimization is performed for deliverable beams with a pencil-beam (PB) dose algorithm. Further deliverable-based optimization proceeds using: (1) MC-based optimization, where dose is recomputed with MC after each intensity update or (2) a once-corrected (OC) MC-hybrid optimization, where a MC dose computation defines beam-by-beam dose correction matrices that are used during a PB-based optimization. Optimizations are performed with nominal per beam MC statistical precisions of 2, 5, 8, 10, 15, and 20%. Following optimizer convergence, beams are re-computed with MC using 2% per beam nominal statistical precision and the 2 PTV and 10 OAR dose indices used in the optimization objective function are tallied. For both the MC-optimization and OC-optimization methods, statistical equivalence tests found that OCEs are less than 1.5% of the prescription dose for plans optimized with nominal statistical uncertainties of up to 10% per beam. The achieved statistical uncertainty in the patient for the 10% per beam simulations from the combination of the 7 beams is ~3% with respect to maximum dose for voxels with D>0.5D(max). The MC dose computation time for the OC-optimization is only 6.2 minutes on a single 3 Ghz processor with results clinically equivalent to high precision MC computations.
Galantamine for Alzheimer's disease.
Olin, J; Schneider, L
2001-01-01
Galantamine (also called galanthamine, marketed as Reminyl (Janssen)) was isolated from several plants, including daffodil bulbs, but is now synthesized. Galantamine is a specific, competitive, and reversible acetylcholinesterase inhibitor. It is also an allosteric modulator at nicotinic cholinergic receptor sites potentiating cholinergic nicotinic neurotransmission. A small number of early studies showed mild cognitive and global benefits for patients with Alzheimer's disease (AD), and recently several multicenter clinical trials have been published with positive findings. Galantamine has received regulatory approval in 29 counties: Argentina, Australia, Canada, Czechia, the European Union (except for The Netherlands), Iceland, Korea, Mexico, Norway, Poland, Singapore, South Africa, Switzerland, Thailand, and the United States. The objective of this overview is to assess the clinical effects of galantamine in patients with probable AD, and to investigate potential moderators of an effect. The trials were identified from a search of the Specialized Register of the Cochrane Dementia and Cognitive Improvement Group on 4 July 2001 using the terms galantamine and Reminyl. The Specialized Register at that time contained records from the following databases: CCTR/Central:April 2001 (issue 2); Medline: 1966 to June 2001; Embase: 1980 to April 2001; PsycLit: 1887 to April 2001; Cinahl: 1982 to March 2001; SIGLE (Grey Literature in Europe): 1980 to December 2000; ISTP (Index to Scientific and Technical Proceedings): to May 2000; INSIDE (BL database of Conference Proceedings and Journals): to June 2000; Aslib Index to Theses (UK and Ireland theses): 1970 to June 2001; Dissertation Abstract (USA): 1861 to June 2001; ADEAR (Alzheimer's Disease Clinical Trials Database): to June 2001; National Research Register (including the MRC Clinical Trials Directory): April 2001 (issue 2) Alzheimers Society Trials Database: to June 2001; Glaxo-Wellcome Trials Database: to June 2001; Centerwatch Trials Database: to December 2000. Published reviews were inspected for further sources. Additional information was collected from an unpublished investigational brochure for galantamine. Trials selected were randomized, double-blind, parallel-group, and unconfounded comparisons of galantamine with placebo for a treatment duration of greater than 4 weeks in subjects with AD. Data were extracted independently by the reviewers and pooled where appropriate and possible. The pooled odds ratios (95%CI) or the average differences (95%CI) were estimated. Intention-to-treat and observed cases data were both reported, if the data were available to be reported. Outcomes of interest include the Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog), clinical global impression of change (CIBIC-plus or CGIC), Alzheimer's Disease Cooperative Study/Activities of Daily Living (ADCS-ADL), Disability Assessment for Dementia scale (DAD) and Neuropsychiatric Inventory (NPI). Potential moderating variables of a treatment effect included trial duration and dose. Seven trials were identified that met criteria for entry, with six being Phase II or III industry-sponsored multicenter trials. Two were of 12 weeks duration; one of 13 weeks, one of 5 months; one of 29 weeks; and two of 6 months duration. Trials of 5 months or more were aggregated together in the analyses as '6 months.' Overall, galantamine showed significant treatment effects at daily doses of 16-32 mg/d for trials of 3- to 6-months duration. For global ratings, trials of 3 months duration with doses of 24-32mg/d (Odds Ratio (OR) 2.3; 95%CI 1.3 - 3.9) and 36mg/d (OR 3.3; 95%CI 1.2 - 9.3) were statistically significant in favor of treatment. For trials of 6 months duration (5-months to 29 weeks), only doses of 8mg/d failed to be statistically significant (16mg: OR 2.25; 95% CI 1.6 - 3.3; 24mg: OR 2.0; 95%CI 1.5 -2.5; 32mg: OR 1.9; 95%CI 1.4 - 2.5). For cognitive function over 6 months duration: at 16mg/d, improvements measured -3.3 points (k=1; 95%CI -4.4 - -2.1) on weighted mean difference on the ADAS-Cog scale; -3.5 points at 24mg/d (k=3; 95%CI -4.3 - -2.8), and -4.0 points at 32mg/d (k=2; 95%CI -5.0 - -3.0). The single 3 month trial with ADAS-Cog data also showed statistically significant improvement. Both observed cases (WMD 3.8; 95%CI 0.3 - 7.3) and intent to treat analyses using the Disability Assessment of Dementia scale gave statistically significant results in favor of treatment for daily doses of 32mg for 6 months duration (as did the single 3 month trial of 24-32mg/d treatment that used this scale) The small number of trials available for analysis, however, limited the power of subgroup analyses to detect differences. Galantamine consistently failed to show statistically significant treatment effects at doses of 8mg/day. Galantamine's adverse effects appear similar to those of other cholinesterase inhibitors, in that it tends to produce gastrointestinal effects acutely and with dosage increases. Overall, subjects treated with galantamine at doses of 24-32 mg/d were more likely to discontinue participation in most trials compared to subjects treated with lower doses or placebo, but in the one trial with a slower rate of titration the discontinuation rate was not significantly greater than placebo for the 16 mg/day dose. Patients in these trials were similar to those seen in earlier antidementia AD trials, and consisted primarily of mildly to moderately impaired outpatients. Galantamine's effects on more severely impaired subjects has not yet been assessed. Nevertheless, this review shows consistent positive effects for galantamine for trials of 3 months, 5 months and 6 months duration. In addition, although there was not a statistically significant dose-response effect, doses above 8mg/d were, for the most part, consistently statistically significant. Thus, there is evidence demonstrating efficacy for galantamine on global ratings, cognitive tests, assessments of ADLs and behavior. This magnitude for the cognitive effect is similar to other cholinesterase inhibitors including donepezil, rivastigmine, and tacrine. Galantamine's safety profile is similar to other cholinesterase inhibitors with respect to cholinergically mediated gastrointestinal symptoms. No information is available on adverse events that occurred less than 5% of the time. It appears that doses of 16 mg/d were best tolerated in the single trial where medication was titrated over 4 week periods, and because this dose showed statistically indistinguishable efficacy with higher doses, it is probably most preferable initially.
Park, Sang Ho; Moon, Young Tae; Myung, Soon Chul; Kim, Tae Hyoung; Chang, In Ho; Kwon, Jong Kyou
2014-01-01
Purpose To evaluate the efficacy of low-dose computed tomography (LDCT) for detecting urinary stones with the use of an iterative reconstruction technique for reducing radiation dose and image noise. Materials and Methods A total of 101 stones from 69 patients who underwent both conventional nonenhanced computed tomography (CCT) and LDCT were analyzed. Interpretations were made of the two scans according to stone characteristics (size, volume, location, Hounsfield unit [HU], and skin-to-stone distance [SSD]) and radiation dose by dose-length product (DLP), effective dose (ED), and image noise. Diagnostic performance for detecting urinary stones was assessed by statistical evaluation. Results No statistical differences were found in stone characteristics between the two scans. The average DLP and ED were 384.60±132.15 mGy and 5.77±1.98 mSv in CCT and 90.08±31.80 mGy and 1.34±0.48 mSv in LDCT, respectively. The dose reduction rate of LDCT was nearly 77% for both DLP and ED (p<0.01). The mean objective noise (standard deviation) from three different areas was 23.0±2.5 in CCT and 29.2±3.1 in LDCT with a significant difference (p<0.05); the slight increase was 21.2%. For stones located throughout the kidney and ureter, the sensitivity and specificity of LDCT remained 96.0% and 100%, with positive and negative predictive values of 100% and 96.2%, respectively. Conclusions LDCT showed significant radiation reduction while maintaining high image quality. It is an attractive option in the diagnosis of urinary stones. PMID:25237459
Tekinarslan, Erdem; Keskin, Suat; Buldu, İbrahim; Sönmez, Mehmet Giray; Karatag, Tuna; Istanbulluoglu, Mustafa Okan
2015-01-01
Introduction To determine and evaluate the effective radiation exposure during a one year follow-up of urolithiasis patients following the SWL (extracorporeal shock wave lithotripsy) treatment. Material and methods Total Effective Radiation Exposure (ERE) doses for each of the 129 patients: 44 kidney stone patients, 41 ureter stone patients, and 44 multiple stone location patients were calculated by adding up the radiation doses of each ionizing radiation session including images (IVU, KUB, CT) throughout a one year follow-up period following the SWL. Results Total mean ERE values for the kidney stone group was calculated as 15, 91 mSv (5.10-27.60), for the ureter group as 13.32 mSv (5.10-24.70), and in the multiple stone location group as 27.02 mSv (9.41-54.85). There was no statistically significant differences between the kidney and ureter groups in terms of the ERE dose values (p = 0.221) (p >0.05). In the comparison of the kidney and ureter stone groups with the multiple stone location group; however, there was a statistically significant difference (p = 0.000) (p <0.05). Conclusions ERE doses should be a factor to be considered right at the initiation of any diagnostic and/or therapeutic procedure. Especially in the case of multiple stone locations, due to the high exposure to ionized radiation, different imaging modalities with low dose and/or totally without a dose should be employed in the diagnosis, treatment, and follow-up bearing the aim to optimize diagnosis while minimizing the radiation dose as much as possible. PMID:26568880
Microdose acquisition in adolescent leg length discrepancy using a low-dose biplane imaging system.
Jensen, Janni; Mussmann, Bo R; Hjarbæk, John; Al-Aubaidi, Zaid; Pedersen, Niels W; Gerke, Oke; Torfing, Trine
2017-09-01
Background Children with leg length discrepancy often undergo repeat imaging. Therefore, every effort to reduce radiation dose is important. Using low dose preview images and noise reduction software rather than diagnostic images for length measurements might contribute to reducing dose. Purpose To compare leg length measurements performed on diagnostic images and low dose preview images both acquired using a low-dose bi-planar imaging system. Material and Methods Preview and diagnostic images from 22 patients were retrospectively collected (14 girls, 8 boys; mean age, 12.8 years; age range, 10-15 years). All images were anonymized and measured independently by two musculoskeletal radiologists. Three sets of measurements were performed on all images; the mechanical axis lines of the femur and the tibia as well as the anatomical line of the entire extremity. Statistical significance was tested with a paired t-test. Results No statistically significant difference was found between measurements performed on the preview and on the diagnostic image. The mean tibial length difference between the observers was -0.06 cm (95% confidence interval [CI], -0.12 to 0.01) and -0.08 cm (95% CI, -0.21 to 0.05), respectively; 0.10 cm (95% CI, 0.02-0.17) and 0.06 cm (95% CI, -0.02 to 0.14) for the femoral measurements and 0.12 cm (95% CI, -0.05 to 0.26) and 0.08 cm (95% CI, -0.02 to 0.19) for total leg length discrepancy. ICCs were >0.99 indicating excellent inter- and intra-rater reliability. Conclusion The data strongly imply that leg length measurements performed on preview images from a low-dose bi-planar imaging system are comparable to measurements performed on diagnostic images.
Hatch, M.; Furukawa, K.; Brenner, A.; Olinjyk, V.; Ron, E.; Zablotska, L.; Terekhova, G.; McConnell, R.; Markov, V.; Shpak, V.; Ostroumova, E.; Bouville, A.; Tronko, M.
2013-01-01
Relatively few data are available on the prevalence of hyperthyroidism (TSH concentrations of < 0.3 mIU/L, with normal or elevated concentrations of free T4) in individuals exposed to radioiodines at low levels. The accident at the Chornobyl (Chernobyl) nuclear plant in Ukraine on April 26, 1986 exposed large numbers of residents to radioactive fallout, principally to iodine-131 (I-131) (mean and median doses = 0.6 Gray (Gy) and 0.2 Gy). We investigated the relationship of I-131 and prevalent hyperthyroidism among 11,853 individuals exposed as children or adolescents in Ukraine who underwent an in-depth, standardized thyroid gland screening examination 12–14 years later. Radioactivity measurements taken shortly after the accident were available for all subjects and were used to estimate individual thyroid doses. We identified 76 cases of hyperthyroidism (11 overt, 65 subclinical). Using logistic regression, we tested a variety of continuous risk models and conducted categorical analyses for all subjects combined and for females (53 cases, n=5,767) and males (23 cases, n=6,086) separately, but found no convincing evidence of a dose response relationship between I-131 and hyperthyroidism. There was some suggestion of elevated risk among females in an analysis based on a dichotomous dose model with a threshold of 0.5 Gy chosen empirically (OR=1.86, P=0.06), but the statistical significance level was reduced (P=0.13) in a formal analysis with an estimated threshold. In summary, after a thorough exploration of the data, we found no statistically significant dose response relationship between individual I-131 thyroid doses and prevalent hyperthyroidism. PMID:21128800
Wang, Gang; Zhang, Yao; Zhang, Sheng; Chen, Huijing; Xu, Zaifeng; Schottenfeld, Richard S; Hao, Wei; Chawarski, Marek Cezary
2016-03-01
We evaluated tolerability and efficacy of aripiprazole and risperidone for treatment of methamphetamine (METH) associated psychotic symptoms in China. Patients with acute METH-associated psychotic symptoms (N=42) and with Positive and Negative Syndrome Scale (PANSS) total score between 60 and 120 were randomized to aripiprazole (initial dose 5-10mg per day followed by flexible doses 5-15 mg per day) or risperidone (initial dose 2-4 mg per day followed by flexible doses 4-6 mg per day) from day 3 to 25 of inpatient hospital stay. Outcome measures included PANSS and Clinical Global Impressions-Severity of Illness scale (CGI-S), METH craving Visual Analogue Scale (VAS), Simpson Angus Scale (SAS), Barnes Assessments Akathasia Rating Scale (BARS), and self-reported adverse effects evaluated during treatment. Retention was evaluated using Kaplan-Meier survival analysis and the MIXED models procedure was used to compare the groups on measures of psychotic and extra-pyramidal symptoms. Patients in both aripiprazole and risperidone groups showed statistically significant reductions in psychotic symptomatology from baseline during treatment (p<0.001) with no statistically significant differences between the treatment groups (p=0.73 and p=0.15, respectively). Risperidone-treated patients reported significantly greater METH craving reductions (p<0.001). Overall, 71% of patients completed the entire study, but the aripiprazole group had a significantly lower retention than the risperidone group (p=0.007), primarily due to medication related adverse effects. Aripiprazole-treated patients also had significantly more akathisia (p=0.03) and agitation (p=0.02) than risperidone-treated patients. Patients in both groups who tolerated their medications and completed the entire study achieved comparable reductions of psychotic symptoms. Copyright © 2015 Elsevier Inc. All rights reserved.
Solomon, Justin; Mileto, Achille; Nelson, Rendon C; Roy Choudhury, Kingshuk; Samei, Ehsan
2016-04-01
To determine if radiation dose and reconstruction algorithm affect the computer-based extraction and analysis of quantitative imaging features in lung nodules, liver lesions, and renal stones at multi-detector row computed tomography (CT). Retrospective analysis of data from a prospective, multicenter, HIPAA-compliant, institutional review board-approved clinical trial was performed by extracting 23 quantitative imaging features (size, shape, attenuation, edge sharpness, pixel value distribution, and texture) of lesions on multi-detector row CT images of 20 adult patients (14 men, six women; mean age, 63 years; range, 38-72 years) referred for known or suspected focal liver lesions, lung nodules, or kidney stones. Data were acquired between September 2011 and April 2012. All multi-detector row CT scans were performed at two different radiation dose levels; images were reconstructed with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) algorithms. A linear mixed-effects model was used to assess the effect of radiation dose and reconstruction algorithm on extracted features. Among the 23 imaging features assessed, radiation dose had a significant effect on five, three, and four of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Adaptive statistical iterative reconstruction had a significant effect on three, one, and one of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). MBIR reconstruction had a significant effect on nine, 11, and 15 of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Of note, the measured size of lung nodules and renal stones with MBIR was significantly different than those for the other two algorithms (P < .002 for all comparisons). Although lesion texture was significantly affected by the reconstruction algorithm used (average of 3.33 features affected by MBIR throughout lesion types; P < .002, for all comparisons), no significant effect of the radiation dose setting was observed for all but one of the texture features (P = .002-.998). Radiation dose settings and reconstruction algorithms affect the extraction and analysis of quantitative imaging features in lesions at multi-detector row CT.
Influence of lead apron shielding on absorbed doses from cone-beam computed tomography.
Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ichiro; Sawada, Kunihiko; Schulze, Dirk
2017-06-01
The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO® phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500®, ProMax® 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax® 3D with shielding, the ED was 149 µSv, and for the examination protocol without shielding 148 µSv (SD = 0.31 µSv). For the CS 9500®, the ED was 88 and 86 µSv (SD = 0.95 µSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, V; Tran, A; Nguyen, D
Purpose: To demonstrate significant organ-at-risk (OAR) sparing achievable with 4π non-coplanar radiotherapy on spine SBRT and SRS patients. Methods: Twenty-five stereotactic spine cases previously treated with VMAT (n = 23) or IMRT (n = 2) were included in this study. A computer-aided-design model of a Linac with a 3D-scanned human surface was utilized to determine the feasible beam space throughout the 4π steradian and beam specific source-to-target-distances (STD) required for collision avoidance. 4π radiotherapy plans integrating beam orientation and fluence map optimization were then created using a column-generation algorithm. Twenty optimal beams were selected for each case. To evaluate themore » tradeoff between dosimetric benefit and treatment complexity, 4π plans including only isocentrically deliverable beams were also created. Beam angles of all standard and isocentric 4π plans were imported into Eclipse to recalculate the dose using the same calculation engine as the clinical plans for unbiased comparison. OAR and PTV dose statistics for the clinical, standard-4π, and isocentric-4π plans were compared. Results: Comparing standard-4π to clinical plans, particularly significant average percent reduction in the [mean, maximum] dose of the cord and esophagus of [41%, 21.7%], and [38.7%, 36.4%] was observed, along with global decrease in all other OAR dose statistics. The average cord volume receiving more than 50% prescription dose was substantially decreased by 76%. In addition, improved PTV coverage was demonstrated with a maximum dose reduction of 0.93% and 1.66% increase in homogeneity index (D95/D5). All isocentric-4π plans achieved dosimetric performance equivalent to that of the standard-4π plans with higher delivery complexity. Conclusion: 4π radiotherapy significantly improves stereotactic spine treatment dosimetry. With the substantial OAR dose sparing, PTV dose escalation is considerably safer. Isocentric-4π is sufficient to achieve the dosimetric gain. The successful implementation of 4π using an FDA approved planning system paves the way for a prospective clinical trial. Varian Medical Systems, NIH R43CA183390 and R01CA188300, NSF graduate research fellowship DGE-1144087.« less
McKnight, Colin D; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H; Parmar, Hemant A
2014-08-01
Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDIvol) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDIvol value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDIvol for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDIvol in the ASIR group (P < 0.01). There were statistically significant reductions in CTDI for the 3- to 12-year-old ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the homogeneity of variance in the ASIR group compared to the non-ASIR group. Radiologist assessment of gray-white differentiation, sharpness and overall diagnostic quality in ASIR examinations was not substantially different compared to non-ASIR examinations. The use of ASIR in pediatric head CT examinations allows for a 28% CTDIvol reduction in the 3- to 12-year-old age group and a 48% reduction in the >12-year-old age group without substantially affecting image quality.
A highly infective plant-associated bacterium influences reproductive rates in pea aphids
Hendry, Tory A.; Clark, Kelley J.; Baltrus, David A.
2016-01-01
Pea aphids, Acyrthosiphon pisum, have the potential to increase reproduction as a defence against pathogens, though how frequently this occurs or how infection with live pathogens influences this response is not well understood. Here we determine the minimum infective dose of an environmentally common bacterium and possible aphid pathogen, Pseudomonas syringae, to determine the likelihood of pathogenic effects to pea aphids. Additionally, we used P. syringae infection to investigate how live pathogens may alter reproductive rates. We found that oral bacterial exposure decreased subsequent survival of aphids in a dose-dependent manner and we estimate that ingestion of less than 10 bacterial cells is sufficient to increase aphid mortality. Pathogen dose was positively related to aphid reproduction. Aphids exposed to low bacterial doses showed decreased, although statistically indistinguishable, fecundity compared to controls. Aphids exposed to high doses reproduced significantly more than low dose treatments and also more, but not significantly so, than controls. These results are consistent with previous studies suggesting that pea aphids may use fecundity compensation as a response to pathogens. Consequently, even low levels of exposure to a common plant-associated bacterium may therefore have significant effects on pea aphid survival and reproduction. PMID:26998321
A highly infective plant-associated bacterium influences reproductive rates in pea aphids.
Hendry, Tory A; Clark, Kelley J; Baltrus, David A
2016-02-01
Pea aphids, Acyrthosiphon pisum, have the potential to increase reproduction as a defence against pathogens, though how frequently this occurs or how infection with live pathogens influences this response is not well understood. Here we determine the minimum infective dose of an environmentally common bacterium and possible aphid pathogen, Pseudomonas syringae, to determine the likelihood of pathogenic effects to pea aphids. Additionally, we used P. syringae infection to investigate how live pathogens may alter reproductive rates. We found that oral bacterial exposure decreased subsequent survival of aphids in a dose-dependent manner and we estimate that ingestion of less than 10 bacterial cells is sufficient to increase aphid mortality. Pathogen dose was positively related to aphid reproduction. Aphids exposed to low bacterial doses showed decreased, although statistically indistinguishable, fecundity compared to controls. Aphids exposed to high doses reproduced significantly more than low dose treatments and also more, but not significantly so, than controls. These results are consistent with previous studies suggesting that pea aphids may use fecundity compensation as a response to pathogens. Consequently, even low levels of exposure to a common plant-associated bacterium may therefore have significant effects on pea aphid survival and reproduction.
Solar UV exposure of primary schoolchildren in Valencia, Spain.
Serrano, María-Antonia; Cañada, Javier; Moreno, Juan Carlos
2011-04-01
To quantify schoolchildren's exposure to ultraviolet erythemal radiation (UVER), personal dosimeters (VioSpor) were used to measure biologically effective ultraviolet (UV) radiation received in the course of their daily school activities. The study took place in two primary schools in Valencia (39°28'N), Spain, for several weeks from March 2008 until May 2009, with two age groups (6-8 years and 10-11 years) and involved about 47 schoolchildren. The median daily UV exposure values for all age groups and solar height intervals considered in the study ranged from 1.31 to 2.11 standard erythemal doses (SEDs). Individual UV exposure was analyzed as a function of age, gender and dosimeter position. Significant statistical differences were found between different age groups, with the younger age group receiving higher statistically significant UVER exposure. It was also found that boys received significantly higher UVER exposure than girls. It was also noted that shoulder dosimeters registered higher readings than wrist dosimeters. Exposure ratio (ER) is defined as the ratio between the personal dose on a selected anatomical site and the corresponding ambient dose on a horizontal plane. The median ER for all age groups and solar height intervals in the study range from 4.5% to 10.7%, with higher values at lower solar heights.
Heskamp, Marie-Luise S; Schramm, Georg A K
2010-01-01
This study investigated the effects of the low-dose combined oral contraceptive (COC) 2.0 mg chlormadinone acetate (CMA)/0.03 mg ethinylestradiol (EE) (Belara, Balanca) on cycle-related physical and emotional disorders in women >or=25 years of age. A prospective, non-interventional, observational study of 3772 women over six cycles was conducted in 303 office-based gynecological centers throughout Germany. CMA/EE provided high contraceptive efficacy with a Pearl index of 0 (95% confidence interval=0.00-0.22) and was generally well tolerated, with no statistically significant weight changes during the observation period (p=.147). CMA/EE intake resulted in a statistically significant improvement in cycle-related physical and emotional symptoms, with a 67% overall reduction in sum score for number and intensity of cycle-related symptoms per patient. The results of this study in women >or=25 years of age support previous findings that 2.0 mg CMA/0.03 mg EE is an effective low-dose COC, with an excellent tolerability profile, with the additional benefits of significantly reducing both cycle-related physical and emotional symptoms (p
Long-Term Dose-Dependent Agalsidase Effects on Kidney Histology in Fabry Disease.
Skrunes, Rannveig; Tøndel, Camilla; Leh, Sabine; Larsen, Kristin Kampevold; Houge, Gunnar; Davidsen, Einar Skulstad; Hollak, Carla; van Kuilenburg, André B P; Vaz, Frédéric M; Svarstad, Einar
2017-09-07
Dose-dependent clearing of podocyte globotriaosylceramide has previously been shown in patients with classic Fabry disease treated with enzyme replacement. Our study evaluates the dose-dependent effects of agalsidase therapy in serial kidney biopsies of patients treated for up to 14 years. Twenty patients with classic Fabry disease (12 men) started enzyme replacement therapy at a median age of 21 (range =7-62) years old. Agalsidase- α or - β was prescribed for a median of 9.4 (range =5-14) years. The lower fixed dose group received agalsidase 0.2 mg/kg every other week throughout the follow-up period. The higher dose group received a range of agalsidase doses (0.2-1.0 mg/kg every other week). Dose changes were made due to disease progression, suboptimal effect, or agalsidase- β shortage. Serial kidney biopsies were performed along with clinical assessment and biomarkers and scored according to recommendations from the International Study Group of Fabry Nephropathy. No statistical differences were found in baseline or final GFR or albuminuria. Kidney biopsies showed significant reduction of podocyte globotriaosylceramide in both the lower fixed dose group (-1.39 [SD=1.04]; P =0.004) and the higher dose group (-3.16 [SD=2.39]; P =0.002). Podocyte globotriaosylceramide (Gb3) reduction correlated with cumulative agalsidase dose ( r =0.69; P =0.001). Arterial/arteriolar intima Gb3 cleared significantly in the higher dose group, all seven patients with baseline intimal Gb3 cleared the intima, one patient gained intimal Gb3 inclusions ( P =0.03), and medial Gb3 did not change statistically in either group. Residual plasma globotriaosylsphingosine levels remained higher in the lower fixed dose group (20.1 nmol/L [SD=11.9]) compared with the higher dose group (10.4 nmol/L [SD=8.4]) and correlated with cumulative agalsidase dose in men ( r =0.71; P =0.01). Reduction of podocyte globotriaosylceramide was found in patients with classic Fabry disease treated with long-term agalsidase on different dosing regimens, correlating with cumulative dose. Limited clearing of arterial/arteriolar globotriaosylceramide raises concerns regarding long-term vascular effects of current therapy. Residual plasma globotriaosylsphingosine correlated with cumulative dose in men. Copyright © 2017 by the American Society of Nephrology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Z; Kennedy, A; Larsen, E
2015-06-15
Purpose: The aim of this study was to investigate the dosimetric impact of the combination of photon energy and treatment technique on radiotherapy of localized prostate cancer when knowledge based planning was used. Methods: A total of 16 patients with localized prostate cancer were retrospectively retrieved from database and used for this study. For each patient, four types of treatment plans with different combinations of photon energy (6X and 10X) and treatment techniques (7-field IMRT and 2-arc VMAT) were created using a prostate DVH estimation model in RapidPlan™ and Eclipse treatment planning system (Varian Medical System). For any beam arrangement,more » DVH objectives and weighting priorities were generated based on the geometric relationship between the OAR and PTV. Photon optimization algorithm was used for plan optimization and AAA algorithm was used for final dose calculation. Plans were evaluated in terms of the pre-defined dosimetric endpoints for PTV, rectum, bladder, penile bulb, and femur heads. A Student’s paired t-test was used for statistical analysis and p > 0.05 was considered statistically significant. Results: For PTV, V95 was statistically similar among all four types of plans, though the mean dose of 10X plans was higher than that of 6X plans. VMAT plans showed higher heterogeneity index than IMRT plans. No statistically significant difference in dosimetry metrics was observed for rectum, bladder, and penile bulb among plan types. For left and right femur, VMAT plans had a higher mean dose than IMRT plans regardless of photon energy, whereas the maximum dose was similar. Conclusion: Overall, the dosimetric endpoints were similar regardless of photon energy and treatment techniques when knowledge based auto planning was used. Given the similarity in dosimetry metrics of rectum, bladder, and penile bulb, the genitourinary and gastrointestinal toxicities should be comparable among the selections of photon energy and treatment techniques.« less
Reproductive toxicologic evaluations of Bulbine natalensis Baker stem extract in albino rats.
Yakubu, M T; Afolayan, A J
2009-08-01
The effects of oral administration of aqueous extract of Bulbine natalensis Baker stem at daily doses of 25, 50, and 100mg/kg body weight on the reproductive function of Wistar rats were evaluated. The indices of mating and fertility success as well as quantal frequency increased after 7 days of treatment in all the dose groups except the 100mg/kg body weight group. The number of litters was not statistically different (P>0.05) from the control. Whereas the absolute weights of the epididymis, seminal vesicle, and prostate were not affected, that of the testes was significantly increased. The epididymal sperm count, motility, morphology, and viscosity were not different from the control after 7 days of treatment. The male rat serum testosterone, progesterone, luteinizing hormone, and follicle-stimulating hormone significantly increased in the 25 and 50mg/kg body weight groups, whereas the estradiol concentration decreased significantly at all the doses. The extract dose of 100mg/kg body weight decreased the serum testosterone and progesterone levels in male rats. The prolactin concentration was not affected by all the doses. All the indices of reproduction, maternal, embryo/fetotoxic, teratogenic, and reproductive hormones in the female rats were not statistically different from that of their control except the resorption index, which increased at the dose of 100mg/kg body weight of the extract. Histologic examination of the cross section of rat testes that received the extract at all the doses investigated revealed well-preserved seminiferous tubules with normal amount of stroma, normal population of spermatogenic and supporting cells, as well as normal spermatocytes within the lumen. The results revealed that the aqueous extract of Bulbine natalensis stem at doses of 25 and 50mg/kg body weight enhanced the success rate of mating and fertility due to increased libido as well as the levels of reproductive hormones in male rats. The absence of alterations in the reproductive parameters of female rats at doses of 25 and 50mg/kg body weight of Bulbine natalensis stem extract suggest that the extract is "safe" for use at these doses by females during the organogenic period of pregnancy, whereas the extract dose of 100mg/kg body weight portends a negative effect on some reproductive functions of male and female rats.
Morelli, John N; Ai, Fei; Runge, Val M; Zhang, Wei; Li, Xiaoming; Schmitt, Peter; McNeal, Gary; Michaely, Henrick J; Schoenberg, Stefan O; Miller, Matthew; Gerdes, Clint M; Sincleair, Spencer T; Spratt, Heidi; Attenberger, Ulrike I
2012-09-01
To establish the minimum dose required for detection of renal artery stenosis using high temporal resolution, contrast enhanced MR angiography (MRA) in a porcine model. Surgically created renal artery stenoses were imaged with 3 Tesla MR and digital subtraction angiography (DSA) in 12 swine in this IACUC approved protocol. Gadobutrol was injected intravenously at doses of 0.5, 1, 2, and 4 mL for time-resolved MRA (1.5 × 1.5 mm(2) spatial resolution). Region of interest analysis was performed together with stenosis assessment and qualitative evaluation by two blinded readers. Mean signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were statistically significantly less with the 0.5-mL protocol (P < 0.001). There were no statistically significant differences among the other evaluated doses. Both readers found 10/12 cases with the 0.5-mL protocol to be of inadequate diagnostic quality (κ = 1.0). All other scans were found to be adequate for diagnosis. Accuracies in distinguishing between mild/insignificant (<50%) and higher grade stenoses (>50%) were comparable among the higher-dose protocols (sensitivities 73-93%, specificities 62-100%). Renal artery stenosis can be assessed with very low doses (~0.025 mmol/kg bodyweight) of a high concentration, high relaxivity gadolinium chelate formulation in a swine model, results which are promising with respect to limiting exposure to gadolinium based contrast agents. Copyright © 2012 Wiley Periodicals, Inc.
Maltoni, M; Nanni, O; Scarpi, E; Rossi, D; Serra, P; Amadori, D
2001-03-01
The aim of the present study was to summarise evidence from scientific studies on cancer anorexia-cachexia syndrome in order to assess and highlight the efficacy of high-dose progestins (megestrol acetate and medroxyprogesterone acetate) compared with placebo in patients with hormone-independent tumors. A systematic review of published randomised clinical trials was carried out by an extensive electronic and hand search through databases, relevant journals and books, congress, proceedings, reference lists, without any language or year of publication restriction. The research was conducted by two independent operators who collected the data in a form specifically designed for this review. Among the several possible outcomes, appetite and body weight were chosen. Fifteen randomised clinical trials (more than 2000 patients) were retrieved for the review. There was a statistically significant advantage for high-dose progestins as regards improved appetite: pooled odds ratio (OR) = 4.23, 95% confidence interval (CI): 2.53-7.04. Although the effect of high-dose progestins on body weight was less impressive, statistical significance was also reached for this outcome: pooled OR = 2.66, 95% CI: 1.80-3.92. Treatment morbidity was very low, due to the brief period of the treatment in most of the studies. The effects of high-dose progestins on appetite and body weight were clearly demonstrated. However, further studies are undoubtedly warranted to investigate other aspects of progestin activity, especially as regards dosage, duration and timing with best therapeutic index.
Al-Ekrish, Asma'a A; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Widmann, Gerlig
2016-10-01
To assess the comparability of linear measurements of dental implant sites recorded from multidetector computed tomography (MDCT) images obtained using standard-dose filtered backprojection (FBP) technique with those from various ultralow doses combined with FBP, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) techniques. The results of the study may contribute to MDCT dose optimization for dental implant site imaging. MDCT scans of two cadavers were acquired using a standard reference protocol and four ultralow-dose test protocols (TP). The volume CT dose index of the different dose protocols ranged from a maximum of 30.48-36.71 mGy to a minimum of 0.44-0.53 mGy. All scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Linear measurements were recorded from standardized images of the jaws by two examiners. Intra- and inter-examiner reliability of the measurements were analyzed using Cronbach's alpha and inter-item correlation. Agreement between the measurements obtained with the reference-dose/FBP protocol and each of the test protocols was determined with Bland-Altman plots and linear regression. Statistical significance was set at a P-value of 0.05. No systematic variation was found between the linear measurements obtained with the reference protocol and the other imaging protocols. The only exceptions were TP3/ASIR-50 (bone kernel) and TP4/ASIR-100 (bone and standard kernels). The mean measurement differences between these three protocols and the reference protocol were within ±0.1 mm, with the 95 % confidence interval limits being within the range of ±1.15 mm. A nearly 97.5 % reduction in dose did not significantly affect the height and width measurements of edentulous jaws regardless of the reconstruction algorithm used.
[The best noise index combined with ASIR weighting selection in low-dose chest scanning].
Xiao, Huijuan; Hou, Ping; Liu, Jie; Gao, Jianbo; Tan, Hongna; Liang, Pan; Pu, Shi
2015-10-06
To discuss the best noise index combined with ASIR weighting selection in low-dose chest scanning based on BMI. 200 patients collected from May to December 2014 underwent non-contrast chest CT examinations, they were randomly assigned into standard dose group (Group A, NI15 combined with 30% ASIR) and low-dose groups (Group B, NI25 combined with 40% ASIR, Group C, NI30 combined with 50% ASIR, Group D, NI35 combined with 60% ASIR), 50 cases in each group; the patients were assigned into three groups based on BMI (kg/m2): BMI<18.5; 18.5≤BMI≤25; BMI>25. Signal-to-nosie ratio (SNR), contrast-to noise ratio (CNR), CT dose index volume (CTDIvol), dose-length product (DLP), effective dose (ED) and subjective scoring between the standard and low-dose groups were compared and analyzed statistically. Differences of SNR, CNR, CTDIvol, DLP and ED among groups were determined with ANOVA analysis and the consistency of diagnosis with Kappa test. SNR, CTDIvol, DLP and ED reduced with the increase of nosie index, the differences among the groups were statistically significant (P<0.05). Kappa value of the two reviewers were 0.888. Subjective scoring of four groups were all above 3 points in BMI<18.5 kg/m2 group; subjective scoring of ABC groups were all above 3 points in 18.5 kg/m2≤BMI≤25 kg/m2 group and subjective scoring of AB groups were all above 3 points in BMI>25 kg/m2 group. NI35 combined with 60% ASIR in BMI<18.5 kg/m2 group; NI30 combined with 50% ASIR in 18.5 kg/m2≤BMI≤25 kg/m2 group; NI25 combined with 40% ASIR in 18.5 kg/m2≤BMI≤25 kg/m2 group were the best parameters combination which both can significantly reduce the radiation dose and ensure the image quality.
The effectiveness of steroids for edema, ecchymosis, and intraoperative bleeding in rhinoplasty.
Koc, Sema; Gürbüzler, Levent; Yaman, Hüseyin; Eyibilen, Ahmet; Süren, Mustafa; Kaya, Ziya; Yelken, Kursat; Aladağ, Ibrahim
2011-01-01
The aim of this study was to investigate the dose-related effectiveness of steroids on periorbital edema, ecchymosis, and intraoperative bleeding in patients who underwent open rhinoplasty with osteotomy. Forty patients were divided into three groups: those in group 1 (n = 15) were given a single dose of 1-mg/kg intravenous (i.v.) methylprednisolone, those in group 2 (n = 15) were given a single dose of 3-mg/kg i.v. methylprednisolone preoperatively, and group 3 (n = 10) was the control group. Eyelid edema and periorbital soft-tissue ecchymosis were evaluated separately using a scale of 0-4. In groups using the steroid preoperatively, periorbital edema and ecchymosis were significantly lower compared with the control group (p < 0.05). No significant differences were seen clinically or statistically in preventing or reducing either the periorbital ecchymosis or the periorbital edema between groups 1 and 2. Also, there was no significant difference among the groups in terms of bleeding (p > 0.05). No complications with regard to the operation or steroid use were observed. Our results support that steroids significantly decrease periorbital ecchymosis and periorbital edema in open rhinoplasty with osteotomy. Additionally, our results suggest that if the dose of steroids is adjusted according to body weight, there is no significant benefit in a single dose of 3 mg/kg of methylprednisolone over a lower dose of 1 mg/kg and there is no need for higher doses of methylprednisolone administration.
Results of intravenous steroid injection on reduction of postoperative edema in rhinoplasty.
Alajmi, Monther Ali; Al-Abdulhadi, Khalid A; Al-Noumas, Hamoud Saud; Kavitha, Gopalan
2009-12-01
To determine the efficacy of intravenous dexamethasone in reducing postrhinoplasty edema. A prospective, randomized clinical trial with placebo control. Department of Otorhinolaryngology, Al-Sabah and Zain Hospital, Kuwait. Eighty-four patients (male = 28; female = 56) aged between 20 and 40 years, undergoing open rhinoplasty with hump removal and bilateral lateral osteotomies were enrolled in this study. Patients were randomized to receive two doses of 10 mg of dexamethasone intravenously or placebo, first dose during surgery and second dose 12 hours after surgery. Patients were evaluated postoperatively at 24 hours, days 2, 5, 7 and 10 for periorbital edema. 10 mg of dexamethasone given intravenously during rhinoplasty and a second dose 12 hours after surgery, reduced postoperative periorbital edema significantly. This study showed a statistically significant benefit of dexamethasone over placebo in reducing periorbital edema after rhinoplasty. No complications were attributed to the administration of dexamethasone.
Huynh, Lynn; Totev, Todor; Vekeman, Francis; Neary, Maureen P; Duh, Mei S; Benson, Al B
2017-09-01
To calculate the cost reduction associated with diarrhea/flushing symptom resolution/improvement following treatment with above-standard dose octreotide-LAR from the commercial payor's perspective. Diarrhea and flushing are two major carcinoid syndrome symptoms of neuroendocrine tumor (NET). Previously, a study of NET patients from three US tertiary oncology centers (NET 3-Center Study) demonstrated that dose escalation of octreotide LAR to above-standard dose resolved/improved diarrhea/flushing in 79% of the patients within 1 year. Time course of diarrhea/flushing symptom data were collected from the NET 3-Center Study. Daily healthcare costs were calculated from a commercial claims database analysis. For the patient cohort experiencing any diarrhea/flushing symptom resolution/improvement, their observation period was divided into days of symptom resolution/improvement or no improvement, which were then multiplied by the respective daily healthcare cost and summed over 1 year to yield the blended mean annual cost per patient. For patients who experienced no diarrhea/flushing symptom improvement, mean annual daily healthcare cost of diarrhea/flushing over a 1-year period was calculated. The economic model found that 108 NET patients who experienced diarrhea/flushing symptom resolution/improvement within 1 year had statistically significantly lower mean annual healthcare cost/patient than patients with no symptom improvement, by $14,766 (p = .03). For the sub-set of 85 patients experiencing resolution/improvement of diarrhea, their cost reduction was more pronounced, at $18,740 (p = .01), statistically significantly lower than those with no improvement; outpatient costs accounted for 56% of the cost reduction (p = .02); inpatient costs, emergency department costs, and pharmacy costs accounted for the remaining 44%. The economic model relied on two different sources of data, with some heterogeneity in the prior treatment and disease status of patients. Symptom resolution/improvement of diarrhea/flushing after treatment with an above-standard dose of octreotide-LAR in NET was associated with a statistically significant healthcare cost decrease compared to a scenario of no symptom improvement.
Impact of Mobile Dose-Tracking Technology on Medication Distribution at an Academic Medical Center.
Kelm, Matthew; Campbell, Udobi
2016-05-01
Medication dose-tracking technologies have the potential to improve efficiency and reduce costs associated with re-dispensing doses reported as missing. Data describing this technology and its impact on the medication use process are limited. The purpose of this study is to assess the impact of dose-tracking technology on pharmacy workload and drug expense at an academic, acute care medical center. Dose-tracking technology was implemented in June 2014. Pre-implementation data were collected from February to April 2014. Post-implementation data were collected from July to September 2014. The primary endpoint was the percent of re-dispensed oral syringe and compounded sterile product (CSP) doses within the pre- and post-implementation periods per 1,000 discharges. Secondary endpoints included pharmaceutical expense generated from re-dispensing doses, labor costs, and staff satisfaction with the medication distribution process. We observed an average 6% decrease in re-dispensing of oral syringe and CSP doses from pre- to post-implementation (15,440 vs 14,547 doses; p = .047). However, when values were adjusted per 1,000 discharges, this trend did not reach statistical significance (p = .074). Pharmaceutical expense generated from re-dispensing doses was significantly reduced from pre- to post-implementation ($834,830 vs $746,466 [savings of $88,364]; p = .047). We estimated that $2,563 worth of technician labor was avoided in re-dispensing missing doses. We also saw significant improvement in staff perception of technology assisting in reducing missing doses (p = .0003), as well as improvement in effectiveness of resolving or minimizing missing doses (p = .01). The use of mobile dose-tracking technology demonstrated meaningful reductions in both the number of doses re-dispensed and cost of pharmaceuticals dispensed.
Behrouzvaziri, Abolhassan; Fu, Daniel; Tan, Patrick; Yoo, Yeonjoo; Zaretskaia, Maria V.; Rusyniak, Daniel E.; Molkov, Yaroslav I.; Zaretsky, Dmitry V.
2015-01-01
Experimental Data Orexinergic neurotransmission is involved in mediating temperature responses to methamphetamine (Meth). In experiments in rats, SB-334867 (SB), an antagonist of orexin receptors (OX1R), at a dose of 10 mg/kg decreases late temperature responses (t>60 min) to an intermediate dose of Meth (5 mg/kg). A higher dose of SB (30 mg/kg) attenuates temperature responses to low dose (1 mg/kg) of Meth and to stress. In contrast, it significantly exaggerates early responses (t<60 min) to intermediate and high doses (5 and 10 mg/kg) of Meth. As pretreatment with SB also inhibits temperature response to the stress of injection, traditional statistical analysis of temperature responses is difficult. Mathematical Modeling We have developed a mathematical model that explains the complexity of temperature responses to Meth as the interplay between excitatory and inhibitory nodes. We have extended the developed model to include the stress of manipulations and the effects of SB. Stress is synergistic with Meth on the action on excitatory node. Orexin receptors mediate an activation of on both excitatory and inhibitory nodes by low doses of Meth, but not on the node activated by high doses (HD). Exaggeration of early responses to high doses of Meth involves disinhibition: low dose of SB decreases tonic inhibition of HD and lowers the activation threshold, while the higher dose suppresses the inhibitory component. Using a modeling approach to data assimilation appears efficient in separating individual components of complex response with statistical analysis unachievable by traditional data processing methods. PMID:25993564
Clancy, J P; Rowe, Steven M; Accurso, Frank J; Aitken, Moira L; Amin, Raouf S; Ashlock, Melissa A; Ballmann, Manfred; Boyle, Michael P; Bronsveld, Inez; Campbell, Preston W; De Boeck, Kris; Donaldson, Scott H; Dorkin, Henry L; Dunitz, Jordan M; Durie, Peter R; Jain, Manu; Leonard, Anissa; McCoy, Karen S; Moss, Richard B; Pilewski, Joseph M; Rosenbluth, Daniel B; Rubenstein, Ronald C; Schechter, Michael S; Botfield, Martyn; Ordoñez, Claudia L; Spencer-Green, George T; Vernillet, Laurent; Wisseh, Steve; Yen, Karl; Konstan, Michael W
2012-01-01
VX-809, a cystic fibrosis transmembrane conductance regulator (CFTR) modulator, has been shown to increase the cell surface density of functional F508del-CFTR in vitro. A randomised, double-blind, placebo-controlled study evaluated the safety, tolerability and pharmacodynamics of VX-809 in adult patients with cystic fibrosis (n=89) who were homozygous for the F508del-CFTR mutation. Subjects were randomised to one of four VX-809 28 day dose groups (25, 50, 100 and 200 mg) or matching placebo. The type and incidence of adverse events were similar among VX-809- and placebo-treated subjects. Respiratory events were the most commonly reported and led to discontinuation by one subject in each active treatment arm. Pharmacokinetic data supported a once-daily oral dosing regimen. Pharmacodynamic data suggested that VX-809 improved CFTR function in at least one organ (sweat gland). VX-809 reduced elevated sweat chloride values in a dose-dependent manner (p=0.0013) that was statistically significant in the 100 and 200 mg dose groups. There was no statistically significant improvement in CFTR function in the nasal epithelium as measured by nasal potential difference, nor were there statistically significant changes in lung function or patient-reported outcomes. No maturation of immature F508del-CFTR was detected in the subgroup that provided rectal biopsy specimens. In this study, VX-809 had a similar adverse event profile to placebo for 28 days in F508del-CFTR homozygous patients, and demonstrated biological activity with positive impact on CFTR function in the sweat gland. Additional data are needed to determine how improvements detected in CFTR function secondary to VX-809 in the sweat gland relate to those measurable in the respiratory tract and to long-term measures of clinical benefit. NCT00865904.
Kamran, Sophia C; Manuel, Matthias M; Cho, Linda P; Damato, Antonio L; Schmidt, Ehud J; Tempany, Clare; Cormack, Robert A; Viswanathan, Akila N
2017-05-01
The purpose was to compare local control (LC), overall survival (OS) and dose to the organs at risk (OAR) in women with locally advanced cervical cancer treated with MR-guided versus CT-guided interstitial brachytherapy (BT). 56 patients (29 MR, 27 CT) were treated with high-dose-rate (HDR) interstitial BT between 2005-2015. The MR patients had been prospectively enrolled on a Phase II clinical trial. Data were analyzed using Kaplan-Meier (K-M) and Cox proportional hazards statistical modeling in JMP® & R®. Median follow-up time was 19.7months (MR group) and 18.4months (CT group). There were no statistically significant differences in patient age at diagnosis, histology, percent with tumor size >4cm, grade, FIGO stage or lymph node involvement between the groups. Patients in the MR group had more lymphovascular involvement compared to patients in the CT group (p<0.01). When evaluating plans generated, there were no statistically significant differences in median cumulative dose to the high-risk clinical target volume or the OAR. 2-year K-M LC rates for MR-based and CT-based treatments were 96% and 87%, respectively (log-rank p=0.65). At 2years, OS was significantly better in the MR-guided cohort (84% vs. 56%, p=0.036). On multivariate analysis, squamous histology was associated with longer OS (HR 0.23, 95% CI 0.07-0.72) in a model with MR BT (HR 0.35, 95% CI 0.08-1.18). There was no difference in toxicities between CT and MR BT. In this population of locally advanced cervical-cancer patients, MR-guided HDR BT resulted in estimated 96% 2-year local control and excellent survival and toxicity rates. Copyright © 2017 Elsevier Inc. All rights reserved.
Chacra, A R; Tan, G H; Apanovitch, A; Ravichandran, S; List, J; Chen, R
2009-09-01
Assess the efficacy and safety of saxagliptin added to a submaximal sulphonylurea dose vs. uptitration of sulphonylurea monotherapy in patients with type 2 diabetes and inadequate glycaemic control with sulphonylurea monotherapy. A total of 768 patients (18-77 years; HbA(1c) screening >or= 7.5 to
Convolutional auto-encoder for image denoising of ultra-low-dose CT.
Nishio, Mizuho; Nagashima, Chihiro; Hirabayashi, Saori; Ohnishi, Akinori; Sasaki, Kaori; Sagawa, Tomoyuki; Hamada, Masayuki; Yamashita, Tatsuo
2017-08-01
The purpose of this study was to validate a patch-based image denoising method for ultra-low-dose CT images. Neural network with convolutional auto-encoder and pairs of standard-dose CT and ultra-low-dose CT image patches were used for image denoising. The performance of the proposed method was measured by using a chest phantom. Standard-dose and ultra-low-dose CT images of the chest phantom were acquired. The tube currents for standard-dose and ultra-low-dose CT were 300 and 10 mA, respectively. Ultra-low-dose CT images were denoised with our proposed method using neural network, large-scale nonlocal mean, and block-matching and 3D filtering. Five radiologists and three technologists assessed the denoised ultra-low-dose CT images visually and recorded their subjective impressions of streak artifacts, noise other than streak artifacts, visualization of pulmonary vessels, and overall image quality. For the streak artifacts, noise other than streak artifacts, and visualization of pulmonary vessels, the results of our proposed method were statistically better than those of block-matching and 3D filtering (p-values < 0.05). On the other hand, the difference in the overall image quality between our proposed method and block-matching and 3D filtering was not statistically significant (p-value = 0.07272). The p-values obtained between our proposed method and large-scale nonlocal mean were all less than 0.05. Neural network with convolutional auto-encoder could be trained using pairs of standard-dose and ultra-low-dose CT image patches. According to the visual assessment by radiologists and technologists, the performance of our proposed method was superior to that of large-scale nonlocal mean and block-matching and 3D filtering.
Sex-related differential susceptibility to doxorubicin-induced cardiotoxicity in B6C3F{sub 1} mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, G. Ronald
Sex is a risk factor for development of cardiotoxicity, induced by the anti-cancer drug, doxorubicin (DOX), in humans. To explore potential mechanisms underlying differential susceptibility to DOX between sexes, 8-week old male and female B6C3F{sub 1} mice were dosed with 3 mg/kg body weight DOX or an equivalent volume of saline via tail vein once a week for 6, 7, 8, and 9 consecutive weeks, resulting in 18, 21, 24, and 27 mg/kg cumulative DOX doses, respectively. At necropsy, one week after each consecutive final dose, the extent of myocardial injury was greater in male mice compared to females asmore » indicated by higher plasma concentrations of cardiac troponin T at all cumulative DOX doses with statistically significant differences between sexes at the 21 and 24 mg/kg cumulative doses. A greater susceptibility to DOX in male mice was further confirmed by the presence of cytoplasmic vacuolization in cardiomyocytes, with left atrium being more vulnerable to DOX cardiotoxicity. The number of TUNEL-positive cardiomyocytes was mostly higher in DOX-treated male mice compared to female counterparts, showing a statistically significant sex-related difference only in left atrium at 21 mg/kg cumulative dose. DOX-treated male mice also had an increased number of γ-H2A.X-positive (measure of DNA double-strand breaks) cardiomyocytes compared to female counterparts with a significant sex effect in the ventricle at 27 mg/kg cumulative dose and right atrium at 21 and 27 mg/kg cumulative doses. This newly established mouse model provides a means to identify biomarkers and access potential mechanisms underlying sex-related differences in DOX-induced cardiotoxicity. - Highlights: • Doxorubicin caused greater heart injury in male mice than females. • Doxorubicin caused vacuolization in cardiomyocytes only in male mice. • TUNEL-positive cardiomyocytes was higher in DOX-treated male mice. • γ-H2A.X-positive cardiomyocytes was greater in DOX-treated male mice.« less
Horikawa, Reiko; Tanaka, Toshiaki; Nishinaga, Hiromi; Ogawa, Yoshihisa; Yokoya, Susumu
2017-01-01
Abstract. Some children born small for gestational age (SGA) have short stature and are at an increased risk of developing psychosocial or behavioral problems. Here we evaluated the efficacy of GH and its effects on the timing of pubertal onset in a 3-yr extension of our previous 2-yr (total 5 yr) multicenter, randomized, double-blind, parallel-group clinical trial of 65 short Japanese children born SGA. Patients received low or high doses of GH (0.033 or 0.067 mg/kg/day, respectively). Age at onset of puberty was not statistically different for male and female patients receiving high- or low-dose GH. After the onset of puberty, no difference in height gain was observed between the two GH dose groups. At the onset of puberty, height standard deviation scores for chronological age of boys and girls improved significantly in both dose groups with evidence of a dose-response effect. Mean bone age/chronological age ratios in the low- and high-dose groups were significantly increased compared with baseline, being significantly greater in the high-dose group at 5 yr after treatment initiation. Delayed bone age at baseline was close to chronological age following GH treatment. GH treatment, especially high-dose GH, induced advanced bone age in short children born SGA. PMID:28458458
Yahya, Noorazrul; Chua, Xin-Jane; Manan, Hanani A; Ismail, Fuad
2018-05-17
This systematic review evaluates the completeness of dosimetric features and their inclusion as covariates in genetic-toxicity association studies. Original research studies associating genetic features and normal tissue complications following radiotherapy were identified from PubMed. The use of dosimetric data was determined by mining the statement of prescription dose, dose fractionation, target volume selection or arrangement and dose distribution. The consideration of the dosimetric data as covariates was based on the statement mentioned in the statistical analysis section. The significance of these covariates was extracted from the results section. Descriptive analyses were performed to determine their completeness and inclusion as covariates. A total of 174 studies were found to satisfy the inclusion criteria. Studies published ≥2010 showed increased use of dose distribution information (p = 0.07). 33% of studies did not include any dose features in the analysis of gene-toxicity associations. Only 29% included dose distribution features as covariates and reported the results. 59% of studies which included dose distribution features found significant associations to toxicity. A large proportion of studies on the correlation of genetic markers with radiotherapy-related side effects considered no dosimetric parameters. Significance of dose distribution features was found in more than half of the studies including these features, emphasizing their importance. Completeness of radiation-specific clinical data may have increased in recent years which may improve gene-toxicity association studies.
Analysis of Dose Response for Circulatory Disease After Radiotherapy for Benign Disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Little, Mark P., E-mail: mark.little@nih.gov; Kleinerman, Ruth A.; Stovall, Marilyn
Purpose: To assess the shape of the dose-response for various circulatory disease endpoints, and modifiers by age and time since exposure. Methods and Materials: This was an analysis of the US peptic ulcer data testing for heterogeneity of radiogenic risk by circulatory disease endpoint (ischemic heart, cerebrovascular, other circulatory disease). Results: There were significant excess risks for all circulatory disease, with an excess relative risk Gy{sup -1} of 0.082 (95% CI 0.031-0.140), and ischemic heart disease, with an excess relative risk Gy{sup -1} of 0.102 (95% CI 0.039-0.174) (both p = 0.01), and indications of excess risk for stroke. Theremore » were no statistically significant (p > 0.2) differences between risks by endpoint, and few indications of curvature in the dose-response. There were significant (p < 0.001) modifications of relative risk by time since exposure, the magnitude of which did not vary between endpoints (p > 0.2). Risk modifications were similar if analysis was restricted to patients receiving radiation, although the relative risks were slightly larger and the risk of stroke failed to be significant. The slopes of the dose-response were generally consistent with those observed in the Japanese atomic bomb survivors and in occupationally and medically exposed groups. Conclusions: There were excess risks for a variety of circulatory diseases in this dataset, with significant modification of risk by time since exposure. The consistency of the dose-response slopes with those observed in radiotherapeutically treated groups at much higher dose, as well as in lower dose-exposed cohorts such as the Japanese atomic bomb survivors and nuclear workers, implies that there may be little sparing effect of fractionation of dose or low-dose-rate exposure.« less
Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II.
Tsuda, S; Yoshida, T; Tsutsumi, M; Saito, K
2015-01-01
The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Akuffo, Kwadwo Owusu; Beatty, Stephen; Peto, Tunde; Stack, Jim; Stringham, Jim; Kelly, David; Leung, Irene; Corcoran, Laura; Nolan, John M
2017-10-01
The purpose of this study was to evaluate the impact of supplemental macular carotenoids (including versus not including meso-zeaxanthin) in combination with coantioxidants on visual function in patients with nonadvanced age-related macular degeneration. In this study, 121 participants were randomly assigned to group 1 (Age-Related Eye Disease Study 2 formulation with a low dose [25 mg] of zinc and an addition of 10 mg meso-zeaxanthin; n = 60) or group 2 (Age-Related Eye Disease Study 2 formulation with a low dose [25 mg] of zinc; n = 61). Visual function was assessed using best-corrected visual acuity, contrast sensitivity (CS), glare disability, retinal straylight, photostress recovery time, reading performance, and the National Eye Institute Visual Function Questionnaire-25. Macular pigment was measured using customized heterochromatic flicker photometry. There was a statistically significant improvement in the primary outcome measure (letter CS at 6 cycles per degree [6 cpd]) over time (P = 0.013), and this observed improvement was statistically comparable between interventions (P = 0.881). Statistically significant improvements in several secondary outcome visual function measures (letter CS at 1.2 and 2.4 cpd; mesopic and photopic CS at all spatial frequencies; mesopic glare disability at 1.5, 3, and 6 cpd; photopic glare disability at 1.5, 3, 6, and 12 cpd; photostress recovery time; retinal straylight; mean and maximum reading speed) were also observed over time (P < 0.05, for all), and were statistically comparable between interventions (P > 0.05, for all). Statistically significant increases in macular pigment at all eccentricities were observed over time (P < 0.0005, for all), and the degree of augmentation was statistically comparable between interventions (P > 0.05). Antioxidant supplementation in patients with nonadvanced age-related macular degeneration results in significant increases in macular pigment and improvements in CS and other measures of visual function. (Clinical trial, http://www.isrctn.com/ISRCTN13894787).
NASA Astrophysics Data System (ADS)
McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.
2017-08-01
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.
McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A; Purdie, Thomas G
2017-07-06
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.
Zuo, H L; Deng, Y; Wang, Y F; Gao, L L; Xue, W; Zhu, S Y; Ma, X; Sun, A J
2018-04-25
Objective: To explore the effect of low-dose or standard-dose conjugated equine estrogen (CEE) combined with natural progesterone or dydrogesterone on bone density in menopause syndrome women. Methods: Totally 123 patients with menopause syndrome were recruited and randomly assigned to 3 treatment groups: group A (low-dose CEE+progesterone) , group B (standard-dose CEE+progesterone) , group C (standard-dose CEE+dydrogesterone) . Using continuous sequential regimen, the duration of intervention was 12 cycles. The bone mineral density of lumbar 2-4 and neck of femur, the bone metabolic markers, the level of FSH and estradiol were examined just before the drug administration and 12 months after the beginning of experiment. Results: There were 107 cases completed the one year trial. (1) Bone density: after 12 cycles of treatment, there was no significant change in bone density in group A ( P> 0.05) ; lumbar vertebrae of group B and C increased significantly, at 3.0% and 2.1%respectively (all P< 0.05) . The bone density of left femoral neck of group C significantly increased by 2.9% ( P= 0.029) . There was no significant difference among the treatment groups at the beginning of experiment ( P> 0.05) . (2) Bone metabolic markers: after 12 cycles of treatment, the levels of calcium, phosphorus, alkaline phosphatase, Ca/Cr decreased significantly, the difference were statistically significant (all P< 0.05) . There was no significant difference among the treatment groups at the beginning of experiment ( P> 0.05) . (3) Levels of FSH and estradiol: after 12 cycles of treatment, the levels of FSH in three groups were decreased significantly (all P< 0.01) . The levels of estradiol in three groups were increased significantly (all P< 0.01) . There was no significant difference among the treatment groups at the beginning of experiment ( P> 0.05) . Conclusions: Both low-dose and standard-dose menopause hormone therapy (MHT) could elevate the level of estradiol, reduce bone turnover, prevent bone loss of postmenopausal women effectively. The standard dose of MHT could also increase the density of vertebrae and femoral neck, and generate more clinical benefits.
Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan; Lin, Qiang; Du, Bin; Tian, Xue; Xu, Yong; Wang, Jin; Lu, You; Gong, Youling
2017-01-01
To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V 5 , V 13 , V 20 , mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V 30 for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Chen, Rui; Wang, Haotian; Shi, Jun; Hu, Pei
2016-05-01
CYP2D6 is a high polymorphic enzyme. Determining its phenotype before CYP2D6 substrate treatment can avoid dose-dependent adverse events or therapeutic failures. Alternative phenotyping methods of CYP2D6 were compared to aluate the appropriate and precise time points for phenotyping after single-dose and ultiple-dose of 30-mg controlled-release (CR) dextromethorphan (DM) and to explore the antimodes for potential sampling methods. This was an open-label, single and multiple-dose study. 21 subjects were assigned to receive a single dose of CR DM 30 mg orally, followed by a 3-day washout period prior to oral administration of CR DM 30 mg every 12 hours for 6 days. Metabolic ratios (MRs) from AUC∞ after single dosing and from AUC0-12h at steady state were taken as the gold standard. The correlations of metabolic ratios of DM to dextrorphan (MRDM/DX) values based on different phenotyping methods were assessed. Linear regression formulas were derived to calculate the antimodes for potential sample methods. In the single-dose part of the study statistically significant correlations were found between MRDM/DX from AUC∞ and from serial plasma points from 1 to 30 hours or from urine (all p-values < 0.001). In the multiple-dose part, statistically significant correlations were found between MRDM/DX from AUC0-12h on day 6 and MRDM/DX from serial plasma points from 0 to 36 hours after the last dosing (all p-values < 0.001). Based on reported urinary antimode and linear regression analysis, the antimodes of AUC and plasma points were derived to profile the trend of antimodes as the drug concentrations changed. MRDM/DX from plasma points had good correlations with MRDM/DX from AUC. Plasma points from 1 to 30 hours after single dose of 30-mg CR DM and any plasma point at steady state after multiple doses of CR DM could potentially be used for phenotyping of CYP2D6.
Wolansky, Leo J; Cadavid, Diego; Punia, Vineet; Kim, Soyeon; Cheriyan, Jojy; Haghighi, Mershad; Cook, Stuart D
2015-01-01
The purpose of this study is to report a metabolic abnormality associated with frequent, triple-dose Gadolinium (TdGd) use in MS patients during BECOME trial. Potential clinical adverse events and lab abnormalities were monitored at each monthly MRI visit. Hypophosphatemia was defined as phosphate <2.5 mg/dL. Statistical analysis included McNemar's test for pairwise comparisons across visits and generalized estimating equations (GEE) to fit models over time. Eight hundred seventy seven phosphate values were analyzed from the first 12 months. Compared with 4% of subjects at screening, an average of 15.1% (95% confidence interval (CI): 11.4%-19.7%) of patients had hypophosphatemia at visits from months 1 to 12, during which subjects received serial TdGd. Forty four of seventy five (59%) patients developed hypophosphatemia at least once. We also found a significant increasing trend in hypophosphatemia by visit when treatment groups were evaluated together or separately (p < .001). There was a statistically significant decrease in frequency to 9.8% (95% CI: 4.6-19.8%) by month 24 (p = .005) coinciding with a period of less frequent gadolinium administration. Serial TdGd in MS patients, unrelated to immunomodulatory treatment, was associated with increased frequency of hypophosphatemia that progressed with cumulative triple-dose and markedly decreased in second year, with less frequent triple-dose administration. Copyright © 2015 by the American Society of Neuroimaging.
Froum, Stuart J; Wallace, Stephen; Cho, Sang-Choon; Khouly, Ismael; Rosenberg, Edwin; Corby, Patricia; Froum, Scott; Mascarenhas, Patrick; Tarnow, Dennis P
2014-01-01
The purpose of this study was to radiographically evaluate, then analyze, bone height, volume, and density with reference to percentage of vital bone after maxillary sinuses were grafted using two different doses of recombinant human bone morphogenetic protein 2/acellular collagen sponge (rhBMP-2/ACS) combined with mineralized cancellous bone allograft (MCBA) and a control sinus grafted with MCBA only. A total of 18 patients (36 sinuses) were used for analysis of height and volume measurements, having two of three graft combinations (one in each sinus): (1) control, MCBA only; (2) test 1, MCBA + 5.6 mL of rhBMP-2/ACS (containing 8.4 mg of rhBMP-2); and (3) test 2, MCBA + 2.8 mL of rhBMP-2/ACS (containing 4.2 mg of rhBMP-2). The study was completed with 16 patients who also had bilateral cores removed 6 to 9 months following sinus augmentation. A computer software system was used to evaluate 36 computed tomography scans. Two time points where selected for measurements of height: The results indicated that height of the grafted sinus was significantly greater in the treatment groups compared with the control. However, by the second time point, there were no statistically significant differences. Three weeks post-surgery bone volume measurements showed similar statistically significant differences between test and controls. However, prior to core removal, test group 1 with the greater dose of rhBMP-2 showed a statistically significant greater increase compared with test group 2 and the control. There was no statistically significant difference between the latter two groups. All three groups had similar volume and shrinkage. Density measurements varied from the above results, with the control showing statistically significant greater density at both time points. By contrast, the density increase over time in both rhBMP groups was similar and statistically higher than in the control group. There were strong associations between height and volume in all groups and between volume and new vital bone only in the control group. There were no statistically significant relationships observed between height and bone density or between volume and bone density for any parameter measured. More cases and monitoring of the future survival of implants placed in these augmented sinuses are needed to verify these results.
De Bondt, Timo; Mulkens, Tom; Zanca, Federica; Pyfferoen, Lotte; Casselman, Jan W; Parizel, Paul M
2017-02-01
To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters. Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking system was used to automatically gather information. Dose (CTDI and DLP), scan length, amount of retakes and demographic data were stratified by age and clinical indication; appropriate use of child-specific protocols was assessed. In total, 296 paediatric cranial CT-procedures were collected. Although the median dose of each hospital was below national and international diagnostic reference level (DRL) for all age categories, statistically significant (p-value < 0.001) dose differences among hospitals were observed. The hospital with lowest dose levels showed smallest dose variability and used age-stratified protocols for standardizing paediatric head exams. Erroneous selection of adult protocols for children still occurred, mostly in the oldest age-group. Even though all hospitals complied with national and international DRLs, dose tracking and benchmarking showed that further dose optimization and standardization is possible by using age-stratified protocols for paediatric cranial CT. Moreover, having a dose tracking system revealed that adult protocols are still applied for paediatric CT, a practice that must be avoided. • Significant differences were observed in the delivered dose between age-groups and hospitals. • Using age-adapted scanning protocols gives a nearly linear dose increase. • Sharing dose-data can be a trigger for hospitals to reduce dose levels.
Jaikuna, Tanwiwat; Khadsiri, Phatchareewan; Chawapun, Nisa; Saekho, Suwit; Tharavichitkul, Ekkasit
2017-02-01
To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD 2 ) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD 2 verification with pair t -test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D 90% , 0.56% in the bladder, 1.74% in the rectum when determined by D 2cc , and less than 1% in Pinnacle. The difference in the EQD 2 between the software calculation and the manual calculation was not significantly different with 0.00% at p -values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.
Khatibi, Bahareh; Said, Engy T; Sztain, Jacklynn F; Monahan, Amanda M; Gabriel, Rodney A; Furnish, Timothy J; Tran, Johnathan T; Donohue, Michael C; Ilfeld, Brian M
2017-04-01
It remains unknown whether continuous or scheduled intermittent bolus local anesthetic administration is preferable for transversus abdominis plane (TAP) catheters. We therefore tested the hypothesis that when using TAP catheters, providing local anesthetic in repeated bolus doses increases the cephalad-caudad cutaneous effects compared with a basal-only infusion. Bilateral TAP catheters (posterior approach) were inserted in 24 healthy volunteers followed by ropivacaine 2 mg/mL administration for a total of 6 hours. The right side was randomly assigned to either a basal infusion (8 mL/h) or bolus doses (24 mL administered every 3 hours for a total of 2 bolus doses) in a double-masked manner. The left side received the alternate treatment. The primary end point was the extent of sensory deficit as measured by cool roller along the axillary line at hour 6 (6 hours after the local anesthetic administration was initiated). Secondary end points included the extent of sensory deficit as measured by cool roller and Von Frey filaments along the axillary line and along a transverse line at the level of the anterior superior iliac spine at hours 0 to 6. Although there were statistically significant differences between treatments within the earlier part of the administration period, by hour 6 the difference in extent of sensory deficit to cold failed to reach statistical significance along the axillary line (mean = 0.9 cm; SD = 6.8; 95% confidence interval -2.0 to 3.8; P = .515) and transverse line (mean = 2.5 cm; SD = 10.1; 95% confidence interval -1.8 to 6.8; P = .244). Although the difference between treatments was statistically significant at various early time points for the horizontal, vertical, and estimated area measurements of both cold and mechanical pressure sensory deficits, no comparison remained statistically significant by hour 6. No evidence was found in this study involving healthy volunteers to support the hypothesis that changing the local anesthetic administration technique (continuous basal versus hourly bolus) when using ropivacaine 0.2% and TAP catheters at 8 mL/h and 24 mL every 3 hours significantly influences the cutaneous effects after 6 hours of administration. Additional research is required to determine whether changing variables (eg, local anesthetic concentration, basal infusion rate, bolus dose volume, and/or interval) would provide different results.
Using venlafaxine to treat behavioral disorders in patients with autism spectrum disorder.
Carminati, Giuliana Galli; Gerber, Fabienne; Darbellay, Barbara; Kosel, Markus Mathaus; Deriaz, Nicolas; Chabert, Jocelyne; Fathi, Marc; Bertschy, Gilles; Ferrero, François; Carminati, Federico
2016-02-04
To test the efficacy of venlafaxine at a dose of 18.75 mg/day on the reduction of behavioral problems such as irritability and hyperactivity/noncompliance in patients with intellectual disabilities and autism spectrum disorder (ASD). Our secondary hypothesis was that the usual doses of zuclopenthixol and/or clonazepam would decrease in the venlafaxine-treated group. In a randomized double-blind study, we compared six patients who received venlafaxine along with their usual treatment (zuclopenthixol and/or clonazepam) with seven patients who received placebo plus usual care. Irritability, hyperactivity/noncompliance, and overall clinical improvement were measured after 2 and 8 weeks, using validated clinical scales. Univariate analyses showed that the symptom of irritability improved in the entire sample (p = 0.023 after 2 weeks, p = 0.061 at study endpoint), although no difference was observed between the venlafaxine and placebo groups. No significant decrease in hyperactivity/noncompliance was observed during the study. At the end of the study, global improvement was observed in 33% of participants treated with venlafaxine and in 71% of participants in the placebo group (p = 0.29). The study found that decreased cumulative doses of clonazepam and zuclopenthixol were required for the venlafaxine group. Multivariate analyses (principal component analyses) with at least three combinations of variables showed that the two populations could be clearly separated (p b 0.05). Moreover, in all cases, the venlafaxine population had lower values for the Aberrant Behavior Checklist (ABC), Behavior Problems Inventory (BPI), and levels of urea with respect to the placebo group. In one case, a reduction in the dosage of clonazepam was also suggested. For an additional set of variables (ABC factor 2, BPI frequency of aggressive behaviors, hematic ammonia at Day 28, and zuclopenthixol and clonazepam intake), the separation between the two samples was statistically significant as was the Bartlett's test, but the Kaiser–Meyer–Olkin Measure of Sampling Adequacy was below the accepted threshold. This set of variables showed a reduction in the cumulative intake of both zuclopenthixol and clonazepam. Despite the small sample sizes, this study documented a statistically significant effect of venlafaxine. Moreover, we showed that lower doses of zuclopenthixol and clonazepam were needed in the venlafaxine group, although this difference was not statistically significant. This was confirmed by multivariate analyses, where this difference reached statistical significance when using a combination of variables involving zuclopenthixol. Larger-scale studies are recommended to better investigate the effectiveness of venlafaxine treatment in patients with intellectual disabilities and ASD.
Ferris, Matthew J; Zhong, Jim; Switchenko, Jeffrey M; Higgins, Kristin A; Cassidy, Richard J; McDonald, Mark W; Eaton, Bree R; Patel, Kirtesh R; Steuer, Conor E; Baddour, H Michael; Miller, Andrew H; Bruner, Deborah W; Xiao, Canhua; Beitler, Jonathan J
2018-01-01
Radiation (RT) dose to the central nervous system (CNS) has been implicated as a contributor to treatment-related fatigue in head and neck cancer (HNC) patients undergoing radiation therapy (RT). This study evaluates the association of RT dose to CNS structures with patient-reported (PRO) fatigue scores in a population of HNC patients. At pre-RT (baseline), 6th week of RT, and 1-month post-RT time points, Multidimensional Fatigue Inventory (MFI-20) scores were prospectively obtained from 124 patients undergoing definitive treatment for HNC. Medulla, pons, midbrain, total brainstem, cerebellum, posterior fossa, and pituitary dosimetry were evaluated using summary statistics and dose-volume histograms, and associations with MFI-20 scores were analyzed. Maximum dose (Dmax) to the brainstem and medulla was significantly associated with MFI-20 scores at 6th week of RT and 1-month post-RT time points, after controlling for baseline scores (p<0.05). Each 1Gy increase in medulla Dmax resulted in an increase in total MFI-20 score over baseline of 0.30 (p=0.026), and 0.25 (p=0.037), at the 6th week of RT and 1-month post-RT, respectively. Each 1Gy increase in brainstem Dmax resulted in an increase in total MFI-20 score over baseline of 0.30 (p=0.027), and 0.25 (p=0.037) at the 6th week of RT, 1-month post-RT, respectively. Statistically significant associations were not found between dosimetry for the other CNS structures and MFI-20 scores. In this analysis of PRO fatigue scores from a population of patients undergoing definitive RT for HNC, maximum dose to the brainstem and medulla was associated with a significantly increased risk of acute patient fatigue. Copyright © 2017 Elsevier B.V. All rights reserved.
Powers, Anna; Loesch, Erin B; Weiland, Anthony; Fioravanti, Nicole; Lucius, David
2017-07-01
To evaluate the utility of a preemptive warfarin dose reduction at the time of initiation of either sulfamethoxazole-trimethoprim or metronidazole, a retrospective chart review of patients who received an outpatient prescription for warfarin and either sulfamethoxazole-trimethoprim and/or metronidazole from July 1, 2011 to July 1, 2015 was conducted. Clinical outcomes compared Veterans who had a warfarin dose reduction and those who did not within 120 h (5 days) of antibiotic initiation. The primary outcome compared the pre-and post-antibiotic International Normalized Ratio (INR) of patients in the intervention group (warfarin dose reduction) with those in the control group (no intervention). Secondary outcomes assessed incidence of thromboembolic and major bleeding events within 30 days of antibiotic completion. Fifty patients were assessed. Forty-nine patients had at least one follow-up appointment; 126 follow-up visits were evaluated. There was a statistically significant difference for the change in therapeutic INR at the first follow-up appointment (p = 0.029) for those patients in the control group. On average, the patients in the intervention group required fewer follow-up visits (p = 0.019). There were no statistically significant differences for the overall rate of therapeutic INR values between groups, as well as no instances of a thromboembolic or major bleeding events during the follow-up period. Clinically significant differences were observed for patients who received a preemptive warfarin dose reduction upon initiation of sulfamethoxazole-trimethoprim or metronidazole. Patients in the intervention group required fewer follow-up appointments and were more likely maintain a therapeutic INR within the 30 days following the antibiotic course. Results of this study will be presented the at Pharmacy and Therapeutics committee in an effort to seek approval for policy development to initiate a local preemptive warfarin dose adjustment as a standard of practice.
Zimushkina, N A; Kosareva, P V; Cherkasova, V G
The objective of the present study was to evaluate the effectiveness of dosed physical exercises for the combined treatment of the patients presenting with mild to moderate dementia associated with Alzheimer's disease (AD). The comprehensive examination involved 41 patients (32 women and 9 men) with the confirmed diagnosis of 'probable' AD with stages 1 and 2 of dementia and 17 healthy volunteers comprising the group of comparison. In all the patients, the neurological examination was supplemented by neuropsychological testing. Two treatment modalities were applied, one being conventional therapy with the use of memantine at the average effective dose, the other with the combination of memantine and dosed physical exercises including elements of cognitive training. In the group of patients treated with memantine alone, changes in cognitive performances among the men did not suggest any statistically significant positive trendency whereas the results of estimation in the women based on the clock drawing test (CDT) and the Mini-Mental State Examination (MMSE) scores revealed the significant improvement of cognitive performances. The most pronounced effects were documented in the women who had received combined therapy with the inclusion of dosed physical exercises in the form of walking. The comparison of the results of the treatment with observations of the patients included in the comparison group demonstrated the improvement of frontal cognitive functioning in the patients of both sexes under the influence of the combined treatment which manifested itself as the absence of the statistically significant differences between the results of the evaluation based on the Frontal Assessment Battery (FAB) scale. The prescription of dosed physical exercises with elements of cognitive training to be applied for the treatment of the patients presenting with dementia of different severity associated with Alzheimer's disease makes it possible to optimize the outcome of the conventional medical treatment and thereby to improve the results of scoring assessments of cognitive performances based on the MMSE, FAB, and CDT scales.
Dogar, Samie A; Khan, Fauzia A
2017-04-01
The tramadol and paracetamol combination is used frequently for postoperative pain management. The literature on the use of this combination for vertebral surgery is limited. Our objective was to compare a combination of paracetamol 1 g and a lower dose of tramadol (1 mg/kg: group 1T) with a combination of paracetamol 1 g and a higher dose of tramadol (1.5 mg/kg: group 1.5T) for postoperative pain after microdisectomy surgery. Our main outcome measure was Visual Analogue Scale pain scores for 4 hours postoperatively. This prospective randomized triple-blind clinical trial was conducted at Aga Khan University Hospital, Karachi. Ninety-four patients aged between 18 and 50 years scheduled for elective single-level microdisectomy were allocated randomly into 1 of 2 groups. Twenty minutes before the end of the surgery, patients received the study drugs. There was no significant demographic difference between groups. None of the patients experienced severe pain (VAS>6). There was no significant difference in the mean pain score between groups. The mean score at 4 hours was 2.17 (1.38) in group 1.5T and 1.74 (1.37) in group 1T. The difference was not statistically significant (P=0.14). In group 1.5T, 13 patients reported having nausea and vomiting compared with 2 patients in group 1T. This was a statistically significant difference (P=0.004). The sedation score was similar between groups. The combination of low-dose tramadol (1 mg/kg) and paracetamol has comparable analgesia and a decreased incidence of nausea and vomiting compared with the higher dose of tramadol (1.5 mg/kg) and paracetamol combination.
Mohareb, Mina W; Abd Elghany, Mohamed; Sabry, Nirmeen A; Farid, Samar F
2016-08-01
High platelet reactivity (HPR) and suboptimal response to dual antiplatelet therapy (DAPT) may explain high recurrent rates of ischemic events in type 1 and 2 diabetes mellitus (DM) patients undergoing percutaneous coronary intervention (PCI). The aim of this study was to determine the effect of diabetes mellitus on clopidogrel activity in cardiac patients undergoing PCI. This is an observational study. Patients were categorized according to DM status into diabetic group (N.=30) and non-diabetic group (N.=33). All patients received clopidogrel in a loading dose of 600 mg before PCI. Platelet function was assessed using light transmittance aggregometry (LTA) technique at baseline (before clopidogrel administration), 24 hour after clopidogrel loading dose administration and 7-10 days after PCI. All patients were followed up for at least one year after PCI for recurrence of acute cardiac events. There was no statistically significant difference between the two groups with respect to 10 µm adenosine diphosphate (ADP)-induced platelet aggregation measured at baseline (P=0.64), 24 hours after PCI (P=0.874), and 7-10 days after PCI (0.643). Diabetics were not significantly different from non-diabetics in terms of post-PCI acute stent thrombosis (P=0.945), sub-acute stent thrombosis (P=0.945), unstable angina (P=0.29) and cardiac death (P=0.64). There was a statistically significant difference between patients with and without post-PCI acute events regarding ADP aggregation measured 24 hours and 7-10 days after PCI. The use of a high loading dose of clopidogrel (600 mg) in patients undergoing elective PCI can overcome the significant increase in post-PCI platelet aggregation and rate of acute cardiac events induced by diabetes mellitus as co-morbidity in those patients.
Zamani, Omid; Böttcher, Elke; Rieger, Jörg D; Mitterhuber, Johann; Hawel, Reinhold; Stallinger, Sylvia; Eller, Norbert
2014-06-01
In this observer-blinded, multicenter, non-inferiority study, 489 patients suffering from painful osteoarthritis of the hip or knee were included to investigate safety and tolerability of Dexibuprofen vs. Ibuprofen powder for oral suspension. Only patients who had everyday joint pain for the past 3 months and "moderate" to "severe" global pain intensity in the involved hip/knee of within the last 48 h were enrolled. The treatment period was up to 14 days with a control visit after 3 days. The test product was Dexibuprofen 400 mg powder for oral suspension (daily dose 800 mg) compared to Ibuprofen 400 mg powder for oral suspension (daily dose 1,600 mg). Gastrointestinal adverse drug reactions were reported in 8 patients (3.3 %) in the Dexibuprofen group and in 19 patients (7.8 %) in the Ibuprofen group. Statistically significant non-inferiority was shown for Dexibuprofen. Comparing both groups by a Chi square test showed a statistical significant lower proportion of related gastrointestinal events in the Dexibuprofen group. All analyses of secondary tolerability parameters showed the same result of a significantly better safety profile in this therapy setting for Dexibuprofen compared to Ibuprofen. The sum of pain intensity, pain relief and global assessments showed no significant difference between treatment groups. In summary, analyses revealed at least non-inferiority in terms of efficacy and a statistically significant better safety profile for the Dexibuprofen treatment.
Filiberti, Rosa A; Fontana, Vincenzo; De Ceglie, Antonella; Blanchi, Sabrina; Grossi, Enzo; Della Casa, Domenico; Lacchin, Teresa; De Matthaeis, Marina; Ignomirelli, Orazio; Cappiello, Roberta; Rosa, Alessandra; Foti, Monica; Laterza, Francesco; D'Onofrio, Vittorio; Iaquinto, Gaetano; Conio, Massimo
2017-04-01
Knowledge about the association between alcohol and Barrett's oesophagus and reflux oesophagitis is conflicting. In this case-control study we evaluated the role of specific alcoholic beverages (red and white wine, beer and liquors) in 339 Barrett's oesophagus and 462 oesophagitis patients compared with 619 endoscopic controls with other disorders, recruited in twelve Italian endoscopic units. Data on alcohol and other individual characteristics were obtained from structured questionnaires. No clear, monotonic significant dose-response relationship was pointed out for red wine. However, a generalised U-shaped trend of Barrett's oesophagus/oesophagitis risk due to red wine consumption particularly among current drinkers was found. Similar results were also found for white wine. Liquor/spirit consumption seemed to bring about a 1·14-2·30 risk excess, although statistically non-significant, for current Barrett's oesophagus/oesophagitis drinkers. Statistically significant decreasing dose-response relationships were found in Barrett's oesophagus for frequency and duration of beer consumption. Similar, but less clear downward tendencies were also found for oesophagitis patients. In conclusion, although often not statistically significant, our data suggested a reduced risk of Barrett's oesophagus and oesophagitis with a low/moderate intake of wine and beer consumption. A non-significant increased risk of Barrett's oesophagus/oesophagitis was observed with a higher intake of any type of heavy alcohol consumption, but no conclusion can be drawn owing to the high number of non-spirit drinkers and to the small number of drinkers at higher alcohol intake levels.
Gender differences in onabotulinum toxin A dosing for adductor spasmodic dysphonia.
Lerner, Michael Z; Lerner, Benjamin A; Patel, Amit A; Blitzer, Andrew
2017-05-01
The objective of this study was to determine the influence of gender on onabotulinum toxin A dosing for the treatment of adductor spasmodic dysphonia symptoms. Retrospective review. A chart review of the senior author's database of botulinum toxin injections was performed. Patients diagnosed with adductor spasmodic dysphonia who received onabotulinum toxin A (BoNTA) injections to the thyroarytenoid muscle for at least 5 years were included for study. Patients who received alternate formulations of botulinum toxin (Myobloc, Dysport, or Xeomin) and patients with alternate diagnoses, such as abductor spasmodic dysphonia, tremor, and oromandibular dystonia, were excluded. The average BoNTA dose was calculated for each patient and statistical analysis was performed comparing the male and female groups. A total of 201 patients (52 males and 149 females) met inclusion criteria. The average follow-up times for the male and female groups were 10.2 ± 3.6 and 11.1 ± 4 years, respectively. The average BoNTA doses for the male and female groups were 0.6 ± 0.42 U and 1.3 ± 1.1 U, respectively. Statistical analysis was performed using an independent samples two-tailed t test yielding a P value of .0000000002. A large effect size was noted with Cohen's d = 0.85. The data from this retrospective chart review reveal a statistically and clinically significant correlation between female gender and higher average BoNTA dose for symptom control in adductor spasmodic dysphonia. Explanations for this observation are speculative and include a possible inverse relationship between optimal BoNTA dose and vocal fold mass and possibly greater neutralizing antibody formation among female patients. 4. Laryngoscope, 127:1131-1134, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duggar, William Neil, E-mail: wduggar@umc.edu; Nguyen, Alex; Stanford, Jason
This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops—Aktina AK550 and Elekta iBEAM evo—of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176more » as well as absolute dose comparison of static fields of 10 × 10 cm{sup 2} that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta{sup 4} dosimetry system (Delta{sup 4}). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta{sup 4} on VMAT and SBRT plans. A credentialing review showed improvement in treatment delivery after couch modeling with both thermoluminescent dosimeter doses and film analysis. Furthermore, analysis of treatment plans with and without using the couch model showed a statistically significant reduction in planning target volume coverage and increase in skin dose. In conclusion, ignoring the treatment couch, a common practice when generating a patient treatment plan, can overestimate the dose delivered especially for arc therapy. This work shows that explicitly modeling the couch during planning can meaningfully improve the agreement between calculated and measured dose distributions. Because of this project, we have implemented the couch models clinically across all treatment plans.« less
Kavuzlu, Ali; Arslan, Necmi; Tastan, Eren; Islam, Ahmet; Ustun, Huseyin; Aydogan, Filiz
2011-11-01
The aim of our study was to investigate the effect of the topical use of mitomycin C (MMC) intraoperatively in single dose and intra-postoperatively in two doses on the narrowing of antrostomy in maxillary rabbit sinus antrostomies created experimentally. And also to determine the local and systemic side effects of topical MMC. With this objective, 0.6 mg/ml MMC was used to the first group at single dose and to the second group intraoperatively and on third day postoperatively in two doses topically for 5 min. After 8 weeks, although the mean area of antrostomy was larger than that in the control side in the first group, which received single dose MMC, the difference was not statistically significant (p = 0.287). The second group received two doses, and the antrostomy areas were found to be significantly larger than the controls (p = 0.05). Overall, the sides that received MMC were significantly larger (p = 0.029). From the point of histopathological examination of the tissue, it was seen that two-dose MMC increased the edema indicating inflammation and antrostomy resolved with normal respiratory tract epithelium. It was shown by measuring the blood values that nephrotoxic and myelosupressant effect of MMC occurring in systemic use did not occur with single or double dose topical use. Our results demonstrate that even if the number of cases was low, two doses of topical MMC usage prevent the narrowing of antrostomy while single dose MMC does not. And two-dose topical MMC usage does not have local and systemic side effects.
Wojakowski, W; Gmiński, J; Stajszczyk, M; Goss, M; Siemianowicz, K; Machalski, M
1999-01-01
In atherosclerosis numerous qualitative and quantitative changes in connective tissue metabolism parameters in serum and aorta occur. In atherosclerosis there is an enhanced activity of local renin-angiotensin systems. It leads to overexpression of ANG II, both in serum and arterial wall. ANG II stimulates SMC to over-synthesize the collagens type I and III. Hyper-cholesterolemia is a form of metabolic injury which can both induce phenotypic change of SMC and activate RA system in arterial wall. ACEI lower the accumulation of collagens type I and III, and enhance elastin content in arterial wall in experimental hypertension. The aim of this study was to assess the influence of captopril, enalapril and quinapril on connective tissue metabolism of the aorta in experimental hyper-cholesterolemia. 64 male New Zealand rabbits were used. Animals were fed with standard fodder, special diet (1% cholesterol content) or special diet + tested ACEI. Two doses of ACE inhibitors were used: 1st--equivalent to doses applied to human subjects (in mg/kg of body weight), 2nd--dose 10 times higher. The animals were divided into 8 equal groups: K--standard fodder, B--special diet, C1, C2--special diet + captopril in doses 2.5 and 25 mg/kg/24 hours, respectively, E1, E2--special diet + enalapril in doses 0.75 and 7.5 mg/kg/24 hours, respectively, Q1 i Q2--special diet + quinapril in doses 0.75 and 7.5 mg/kg per day, respectively. The experiment lasted for 6 months. After 24 weeks the animals were sacrificed and aortae were excised for collagens assay. The statistical analysis was performed using ANOVA, followed by LSD test; p < 0.05 was considered statistically significant. The aorta collagens content of cholesterol-fed rabbits significantly increased. The tested ACEI (captopril, enalapril in both doses and quinapril in lower dose) had a preventive effect against the increase of aorta collagen content.
Fang, Xin; Han, Hedong; Li, Mei; Liang, Chun; Fan, Zhongjie; Aaseth, Jan; He, Jia; Montgomery, Scott; Cao, Yang
2016-11-19
The epidemiological evidence for a dose-response relationship between magnesium intake and risk of type 2 diabetes mellitus (T2D) is sparse. The aim of the study was to summarize the evidence for the association of dietary magnesium intake with risk of T2D and evaluate the dose-response relationship. We conducted a systematic review and meta-analysis of prospective cohort studies that reported dietary magnesium intake and risk of incident T2D. We identified relevant studies by searching major scientific literature databases and grey literature resources from their inception to February 2016. We included cohort studies that provided risk ratios, i.e., relative risks (RRs), odds ratios (ORs) or hazard ratios (HRs), for T2D. Linear dose-response relationships were assessed using random-effects meta-regression. Potential nonlinear associations were evaluated using restricted cubic splines. A total of 25 studies met the eligibility criteria. These studies comprised 637,922 individuals including 26,828 with a T2D diagnosis. Compared with the lowest magnesium consumption group in the population, the risk of T2D was reduced by 17% across all the studies; 19% in women and 16% in men. A statistically significant linear dose-response relationship was found between incremental magnesium intake and T2D risk. After adjusting for age and body mass index, the risk of T2D incidence was reduced by 8%-13% for per 100 mg/day increment in dietary magnesium intake. There was no evidence to support a nonlinear dose-response relationship between dietary magnesium intake and T2D risk. The combined data supports a role for magnesium in reducing risk of T2D, with a statistically significant linear dose-response pattern within the reference dose range of dietary intake among Asian and US populations. The evidence from Europe and black people is limited and more prospective studies are needed for the two subgroups.
Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni
2016-01-01
Background Iterative reconstruction methods have attracted attention for reducing radiation doses in computed tomography (CT). Purpose To investigate the detectability of pancreatic calcification using dose-reduced CT reconstructed with model-based iterative construction (MBIR) and adaptive statistical iterative reconstruction (ASIR). Material and Methods This prospective study approved by Institutional Review Board included 85 patients (57 men, 28 women; mean age, 69.9 years; mean body weight, 61.2 kg). Unenhanced CT was performed three times with different radiation doses (reference-dose CT [RDCT], low-dose CT [LDCT], ultralow-dose CT [ULDCT]). From RDCT, LDCT, and ULDCT, images were reconstructed with filtered-back projection (R-FBP, used for establishing reference standard), ASIR (L-ASIR), and MBIR and ASIR (UL-MBIR and UL-ASIR), respectively. A lesion (pancreatic calcification) detection test was performed by two blinded radiologists with a five-point certainty level scale. Results Dose-length products of RDCT, LDCT, and ULDCT were 410, 97, and 36 mGy-cm, respectively. Nine patients had pancreatic calcification. The sensitivity for detecting pancreatic calcification with UL-MBIR was high (0.67–0.89) compared to L-ASIR or UL-ASIR (0.11–0.44), and a significant difference was seen between UL-MBIR and UL-ASIR for one reader (P = 0.014). The area under the receiver-operating characteristic curve for UL-MBIR (0.818–0.860) was comparable to that for L-ASIR (0.696–0.844). The specificity was lower with UL-MBIR (0.79–0.92) than with L-ASIR or UL-ASIR (0.96–0.99), and a significant difference was seen for one reader (P < 0.01). Conclusion In UL-MBIR, pancreatic calcification can be detected with high sensitivity, however, we should pay attention to the slightly lower specificity. PMID:27110389
Saleh, Muneer Aziz; Ramli, Ahmad Termizi; bin Hamzah, Khaidzir; Alajerami, Yasser; Moharib, Mohammed; Saeed, Ismael
2015-10-01
This study aims to predict and estimate unmeasured terrestrial gamma dose rate (TGDR) using statistical analysis methods to derive a model from the actual measurement based on geological formation and soil type. The measurements of TGDR were conducted in the state of Johor with a total of 3873 measured points which covered all geological formations, soil types and districts. The measurements were taken 1 m above the soil surface using NaI [Ti] detector. The measured gamma dose rates ranged from 9 nGy h(-1) to 1237 nGy h(-1) with a mean value of 151 nGy h(-1). The data have been normalized to fit a normal distribution. Tests of significance were conducted among all geological formations and soil types, using the unbalanced one way ANOVA. The results indicated strong significant differences due to the different geological formations and soil types present in Johor State. Pearson Correlation was used to measure the relations between gamma dose rate based on geological formation and soil type (D(G,S)) with the gamma dose rate based on geological formation (D(G)) or soil type (D(s)). A very good correlation was found between D(G,S) and D(G) or D(G,S) and D(s). A total of 118 pairs of geological formations and soil types were used to derive the statistical contribution of geological formations and soil types to gamma dose rates. The contribution of the gamma dose rate from geological formation and soil type were found to be 0.594 and 0.399, respectively. The null hypotheses were accepted for 83% of examined data, therefore, the model could be used to predict gamma dose rates based on geological formation and soil type information. Copyright © 2015 Elsevier Ltd. All rights reserved.
Awad, Kamal; Serban, Maria-Corina; Penson, Peter; Mikhailidis, Dimitri P; Toth, Peter P; Jones, Steven R; Rizzo, Manfredi; Howard, George; Lip, Gregory Y H; Banach, Maciej
Evidence about the optimal time of day at which to administer statins is lacking. The objective of this study is to synthesize evidence about effects of morning vs evening statin administration on lipid profile. We searched PubMed, SCOPUS, Web of Science, and Embase databases (from inception up to July 24, 2016) to identify the relevant studies. Mean differences (MDs) between the change scores in lipid parameters were pooled using a fixed-effect model. Eleven articles with 1034 participants were eligible for the analysis. The pooled analysis comparing effects of morning vs evening administration of statins on plasma total cholesterol (TC; P = .10), high-density lipoprotein cholesterol (P = .90), and triglycerides (P = .45) was not statistically significant. Low-density lipoprotein cholesterol (LDL-C) lowering was statistically greater in the evening-dose group (MD: 3.24 mg/dL, 95% CI: 1.23-5.25, P = .002). Subgroup analysis according to statin half-lives showed that evening dose of statins was significantly superior to morning dose for lowering LDL-C in case of both short and long half-life statins (MD: 9.68 mg/dL, 95% CI: 3.32-16.03, P = .003 and MD: 2.53 mg/dL, 95% CI: 0.41-4.64, P = .02, respectively) and also for TC reduction in case of short half-life statins only (P = .0005). LDL-C and TC lowering was significantly greater in the evening dose than in the morning dose in case of short-acting statins. Besides slight but significant effect on LDL-C, the efficacy of long-acting statins was equivalent for both regimens. Therefore, long-acting statins should be given at a time that will best aid compliance. Short-acting statins should be given in the evening. Copyright © 2017 National Lipid Association. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Otter, Sophie; Schick, Ulrike; Gulliford, Sarah
Purpose: The study aimed to apply the atlas of complication incidence (ACI) method to patients receiving radical treatment for head and neck squamous cell carcinomas (HNSCC), to generate constraints based on dose-volume histograms (DVHs), and to identify clinical and dosimetric parameters that predict the risk of grade 3 oral mucositis (g3OM) and pharyngeal dysphagia (g3PD). Methods and Materials: Oral and pharyngeal mucosal DVHs were generated for 253 patients who received radiation (RT) or chemoradiation (CRT). They were used to produce ACI for g3OM and g3PD. Multivariate analysis (MVA) of the effect of dosimetry, clinical, and patient-related variables was performed usingmore » logistic regression and bootstrapping. Receiver operating curve (ROC) analysis was also performed, and the Youden index was used to find volume constraints that discriminated between volumes that predicted for toxicity. Results: We derived statistically significant dose-volume constraints for g3OM over the range v28 to v70. Only 3 statistically significant constraints were derived for g3PD v67, v68, and v69. On MVA, mean dose to the oral mucosa predicted for g3OM and concomitant chemotherapy and mean dose to the inferior constrictor (IC) predicted for g3PD. Conclusions: We have used the ACI method to evaluate incidences of g3OM and g3PD and ROC analysis to generate constraints to predict g3OM and g3PD derived from entire individual patient DVHs. On MVA, the strongest predictors were radiation dose (for g3OM) and concomitant chemotherapy (for g3PD).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kehwar, Than S., E-mail: kehwarts@upmc.ed; Jones, Heather A.; Huq, M. Saiful
2011-06-01
Purpose: To study the influence of prostatic edema on postimplant physical and radiobiological parameters using {sup 131}Cs permanent prostate seed implants. Methods and Materials: Thirty-one patients with early prostate cancer who underwent {sup 131}Cs permanent seed implantation were evaluated. Dose-volume histograms were generated for each set of prostate volumes obtained at preimplantation and postimplantion days 0, 14, and 28 to compute quality indices (QIs) and fractional doses at level x (FD{sub x}). A set of equations for QI, FD{sub x}, and biologically effective doses at dose level D{sub x} (BED{sub x}) were defined to account for edema changes with timemore » after implant. Results: There were statistically significant differences found between QIs of pre- and postimplant plans at day 0, except for the overdose index (ODI). QIs correlated with postimplant time, and FD{sub x} was found to increase with increasing postimplant time. With the effect of edema, BED at different dose levels showed less improvement due to the short half-life of {sup 131}Cs, which delivers about 85% of the prescribed dose before the prostate reaches its original volume due to dissipation of edema. Conclusions: Results of the study show that QIs, FD{sub x}, and BEDs at the level of D{sub x} changed from preneedle plans to postimplant plans and have statistically significant differences (p < 0.05), except for the ODI (p = 0.106), which suggests that at the time of {sup 131}C seed implantation, the effect of edema must be accounted for when defining the seed positions, to avoid the possibility of poor dosimetric and radiobiologic results for {sup 131}Cs seed implants.« less
Dean, Karen M; Bursian, Steven J; Cacela, Dave; Carney, Michael W; Cunningham, Fred L; Dorr, Brian; Hanson-Dorr, Katie C; Healy, Kate A; Horak, Katherine E; Link, Jane E; Lipton, Ian; McFadden, Andrew K; McKernan, Moira A; Harr, Kendal E
2017-12-01
Scoping studies were designed whereby double-crested cormorants (Phalacocorax auritus) were dosed with artificially weathered Deepwater Horizon (DWH) oil either daily through oil injected feeder fish, or by application of oil directly to feathers every three days. Preening results in oil ingestion, and may be an effective means of orally dosing birds with toxicant to improve our understanding of the full range of physiological effects of oral oil ingestion on birds. Blood samples collected every 5-6 days were analyzed for a number of clinical endpoints including white blood cell (WBC) estimates and differential cell counts. Plasma biochemical evaluations were performed for changes associated with oil toxicity. Oral dosing and application of oil to feathers resulted in clinical signs and statistically significant changes in a number of biochemical endpoints consistent with petroleum exposure. In orally dosed birds there were statistically significant decreases in aspartate amino transferase (AST) and gamma glutamyl transferase (GGT) activities, calcium, chloride, cholesterol, glucose, and total protein concentrations, and increases in plasma urea, uric acid, and phosphorus concentrations. Plasma electrophoresis endpoints (pre-albumin, albumin, alpha-2 globulin, beta globulin, and gamma globulin concentrations and albumin: globulin ratios) were decreased in orally dosed birds. Birds with external oil had increases in urea, creatinine, uric acid, creatine kinase (CK), glutamate dehydrogenase (GLDH), phosphorus, calcium, chloride, potassium, albumin, alpha-1 globulin and alpha-2 globulin. Decreases were observed in AST, beta globulin and glucose. WBC also differed between treatments; however, this was in part driven by monocytosis present in the externally oiled birds prior to oil treatment. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saenz, D; Stathakis, S
Purpose: Deep inspiration breath-hold (DIBH) is used for left-sided breast radiotherapy to spare the heart and lung. The magnitude of sparing has been shown to be significant. Monte Carlo, furthermore, has the potential to calculate most accurately the dose in the heterogeneous lung medium at the interface with the lung wall. The lung dose was investigated in Monaco to determine the level of sparing relative to that calculated in Pinnacle{sup 3}. Methods: Five patients undergoing DIBH radiotherapy on an Elekta Versa HD linear accelerator in conjunction with the Catalyst C-RAD surface imaging system were planned using Phillips Pinnacle{sup 3}. Freemore » breathing plans were also created to clinically assure a benefit. Both plans were re-calculated in Monaco to determine if there were any significant differences. The mean heart dose, mean left lung, and mean total lung dose were compared in addition to the V20 for left and both lungs. Dose was calculated as dose to medium as well as dose to water with a statistical precision of 0.7%. Results: Mean lung dose was significantly different (p < 0.003) between the two calculations for both DIBH (11.6% higher in Monaco) and free breathing (14.2% higher in Monaco). V20 was also higher in Monaco (p < 0.05) for DIBH (5.7% higher) and free breathing (4.9% higher). The mean heart dose was not significantly different between the dose calculations for either DIBH or free breathing. Results were no more than 0.1% different when calculated as dose to water. Conclusion: The use of Monte Carlo can provide insight on the lung dose for both free breathing and DIBH techniques for whole breast irradiation. While the sparing (dose reductions with DIBH as compared to free breathing) is equivalent for either planning system, the lung doses themselves are higher when calculated with Monaco.« less
Dose-mass inverse optimization for minimally moving thoracic lesions
NASA Astrophysics Data System (ADS)
Mihaylov, I. B.; Moros, E. G.
2015-05-01
In the past decade, several different radiotherapy treatment plan evaluation and optimization schemes have been proposed as viable approaches, aiming for dose escalation or an increase of healthy tissue sparing. In particular, it has been argued that dose-mass plan evaluation and treatment plan optimization might be viable alternatives to the standard of care, which is realized through dose-volume evaluation and optimization. The purpose of this investigation is to apply dose-mass optimization to a cohort of lung cancer patients and compare the achievable healthy tissue sparing to that one achievable through dose-volume optimization. Fourteen non-small cell lung cancer (NSCLC) patient plans were studied retrospectively. The range of tumor motion was less than 0.5 cm and motion management in the treatment planning process was not considered. For each case, dose-volume (DV)-based and dose-mass (DM)-based optimization was performed. Nine-field step-and-shoot IMRT was used, with all of the optimization parameters kept the same between DV and DM optimizations. Commonly used dosimetric indices (DIs) such as dose to 1% the spinal cord volume, dose to 50% of the esophageal volume, and doses to 20 and 30% of healthy lung volumes were used for cross-comparison. Similarly, mass-based indices (MIs), such as doses to 20 and 30% of healthy lung masses, 1% of spinal cord mass, and 33% of heart mass, were also tallied. Statistical equivalence tests were performed to quantify the findings for the entire patient cohort. Both DV and DM plans for each case were normalized such that 95% of the planning target volume received the prescribed dose. DM optimization resulted in more organs at risk (OAR) sparing than DV optimization. The average sparing of cord, heart, and esophagus was 23, 4, and 6%, respectively. For the majority of the DIs, DM optimization resulted in lower lung doses. On average, the doses to 20 and 30% of healthy lung were lower by approximately 3 and 4%, whereas lung volumes receiving 2000 and 3000 cGy were lower by 3 and 2%, respectively. The behavior of MIs was very similar. The statistical analyses of the results again indicated better healthy anatomical structure sparing with DM optimization. The presented findings indicate that dose-mass-based optimization results in statistically significant OAR sparing as compared to dose-volume-based optimization for NSCLC. However, the sparing is case-dependent and it is not observed for all tallied dosimetric endpoints.
Biological availability and in vitro dissolution of oxytetracycline dihydrate tablets
Barber, H. E.; Calvey, T. N.; Muir, K.; Hart, A.
1974-01-01
1 The concentration of oxytetracycline in plasma was studied by microbiological assay after oral administration of four different preparations of oxytetracycline dihydrate tablets. 2 There were statistically significant differences in biological availability between the four preparations, as assessed by the peak plasma level, the area under the plasma concentration-time curve, or the cumulative fraction of the dose excreted in urine at 405 minutes. In contrast, differences between the subjects were not statistically significant. 3 The differences in biological availability were not predictably related to the in vitro dissolution of the tablets. PMID:22454918
A randomized placebo-controlled trial of repaglinide in the treatment of type 2 diabetes.
Goldberg, R B; Einhorn, D; Lucas, C P; Rendell, M S; Damsbo, P; Huang, W C; Strange, P; Brodows, R G
1998-11-01
The objective of the study was to assess the efficacy and safety of repaglinide compared with placebo in the treatment of patients with type 2 diabetes. This was a phase II multicenter, double-blind, placebo-controlled, randomized, dose-adjustment and maintenance trial. After screening and a 2-week washout period, 99 patients were randomized to receive either repaglinide (n = 66) or placebo (n = 33). Patients underwent 6 weeks of dose adjustment followed by 12 weeks of dose maintenance. Fasting and stimulated glycosylated hemoglobin (HbA1c), plasma glucose, insulin, and C-peptide were measured at predetermined intervals. Adverse events and hypoglycemic episodes were recorded. From baseline to last visit, mean HbA1c decreased from 8.5 to 7.8% in patients treated with repaglinide and increased from 8.1 to 9.3% in patients receiving placebo, with a statistically significant difference of - 1.7% (P < 0.0001) between treatment groups at the last visit. Mean fasting plasma glucose and postprandial glucose increased in patients receiving placebo and decreased in patients treated with repaglinide, with statistically significant (P < 0.01) differences between groups at the last visit. Concentrations of fasting and postprandial insulin and C-peptide were lower at the last visit compared with baseline for patients treated with placebo and higher for patients treated with repaglinide, and the differences between groups were statistically significant (P < 0.05). Overall, repaglinide was well tolerated. This study demonstrated that repaglinide was safe and efficacious in lowering blood glucose concentrations. In addition to overall improvement in glycemic control noted with repaglinide in both sulfonylurea-treated patients and oral hypoglycemic agent-naive patients, repaglinide had a potent glucose-lowering effect in the postprandial period.
Cho, Michael; Atrio, Jessica; Lim, Aaron H; Azen, Colleen; Stanczyk, Frank Z
2014-07-01
The objective was to investigate changes in luteinizing hormone (LH), follicle-stimulating hormone (FSH), estradiol (E2) and progesterone (P) during the hormone-free interval (HFI) of 6 combined oral contraceptives (COCs). Blood samples were obtained from 62 women. When COCs were grouped by ethinyl estradiol (EE) dose, there was a significant positive mean slope for LH and FSH during the HFI for the 30- and 35 mcg-EE doses, whereas 20 showed a gradual nonsignificant slope. All E2 slopes were significant. P remained suppressed with all doses. A more rapid rebound of gonadotropin levels is found with higher doses of EE during the HFI. This study showed a more rapid rebound of pituitary hormone levels among women using higher-EE-dosage formulations, which was demonstrated by the statistically significant slope for mean LH and FSH from day 1 to day 7 of the HFI. The degree of suppression did not vary across progestin generations. It remains to be established whether women who experience side effects during their HFI may benefit from using a COC with a lower EE dose to minimize changes in endogenous pituitary hormone levels. Copyright © 2014 Elsevier Inc. All rights reserved.
Festing, Michael F W
2014-01-01
The safety of chemicals, drugs, novel foods and genetically modified crops is often tested using repeat-dose sub-acute toxicity tests in rats or mice. It is important to avoid misinterpretations of the results as these tests are used to help determine safe exposure levels in humans. Treated and control groups are compared for a range of haematological, biochemical and other biomarkers which may indicate tissue damage or other adverse effects. However, the statistical analysis and presentation of such data poses problems due to the large number of statistical tests which are involved. Often, it is not clear whether a "statistically significant" effect is real or a false positive (type I error) due to sampling variation. The author's conclusions appear to be reached somewhat subjectively by the pattern of statistical significances, discounting those which they judge to be type I errors and ignoring any biomarker where the p-value is greater than p = 0.05. However, by using standardised effect sizes (SESs) a range of graphical methods and an over-all assessment of the mean absolute response can be made. The approach is an extension, not a replacement of existing methods. It is intended to assist toxicologists and regulators in the interpretation of the results. Here, the SES analysis has been applied to data from nine published sub-acute toxicity tests in order to compare the findings with those of the author's. Line plots, box plots and bar plots show the pattern of response. Dose-response relationships are easily seen. A "bootstrap" test compares the mean absolute differences across dose groups. In four out of seven papers where the no observed adverse effect level (NOAEL) was estimated by the authors, it was set too high according to the bootstrap test, suggesting that possible toxicity is under-estimated.
Neonatal outcomes following exposure in utero to fallout from Chernobyl.
Hatch, Maureen; Little, Mark P; Brenner, Alina V; Cahoon, Elizabeth K; Tereshchenko, Valery; Chaikovska, Ludmyla; Pasteur, Igor; Likhtarov, Ilya; Bouville, Andre; Shpak, Victor; Bolshova, Olena; Zamotayeva, Galyna; Grantz, Katherine; Sun, Liping; Mabuchi, Kiyohiko; Albert, Paul; Tronko, Mykola
2017-12-01
Iodine 131 (I-131), the principal component of nuclear fallout from the Chernobyl accident, concentrates in the thyroid gland and may pose risks to fetal development. To evaluate this, neonatal outcomes following the accident in April of 1986 were investigated in a cohort of 2582 in utero-exposed individuals from northern Ukraine for whom estimates of fetal thyroid I-131 dose were available. We carried out a retrospective review of cohort members' prenatal, delivery and newborn records. The relationships of dose with neonatal anthropometrics and gestational length were modeled via linear regression with adjustment for potentially confounding variables. We found similar, statistically significant dose-dependent reductions in both head circumference (-1.0 cm/Gy, P = 0.005) and chest circumference (-0.9 cm/Gy, P = 0.023), as well as a similar but non-significant reduction in neonatal length (-0.6 cm/Gy, P = 0.169). Gestational length was significantly increased with increasing fetal dose (0.5 wks/Gy, P = 0.007). There was no significant (P > 0.1) effect of fetal dose on birth weight. The observed associations of radioiodine exposure with decreased head and chest circumference are consistent with those observed in the Japanese in utero-exposed atomic bomb survivors.
Impact of database quality in knowledge-based treatment planning for prostate cancer.
Wall, Phillip D H; Carver, Robert L; Fontenot, Jonas D
2018-03-13
This article investigates dose-volume prediction improvements in a common knowledge-based planning (KBP) method using a Pareto plan database compared with using a conventional, clinical plan database. Two plan databases were created using retrospective, anonymized data of 124 volumetric modulated arc therapy (VMAT) prostate cancer patients. The clinical plan database (CPD) contained planning data from each patient's clinically treated VMAT plan, which were manually optimized by various planners. The multicriteria optimization database (MCOD) contained Pareto-optimal plan data from VMAT plans created using a standardized multicriteria optimization protocol. Overlap volume histograms, incorporating fractional organ at risk volumes only within the treatment fields, were computed for each patient and used to match new patient anatomy to similar database patients. For each database patient, CPD and MCOD KBP predictions were generated for D 10 , D 30 , D 50 , D 65 , and D 80 of the bladder and rectum in a leave-one-out manner. Prediction achievability was evaluated through a replanning study on a subset of 31 randomly selected database patients using the best KBP predictions, regardless of plan database origin, as planning goals. MCOD predictions were significantly lower than CPD predictions for all 5 bladder dose-volumes and rectum D 50 (P = .004) and D 65 (P < .001), whereas CPD predictions for rectum D 10 (P = .005) and D 30 (P < .001) were significantly less than MCOD predictions. KBP predictions were statistically achievable in the replans for all predicted dose-volumes, excluding D 10 of bladder (P = .03) and rectum (P = .04). Compared with clinical plans, replans showed significant average reductions in D mean for bladder (7.8 Gy; P < .001) and rectum (9.4 Gy; P < .001), while maintaining statistically similar planning target volume, femoral head, and penile bulb dose. KBP dose-volume predictions derived from Pareto plans were more optimal overall than those resulting from manually optimized clinical plans, which significantly improved KBP-assisted plan quality. This work investigates how the plan quality of knowledge databases affects the performance and achievability of dose-volume predictions from a common knowledge-based planning approach for prostate cancer. Bladder and rectum dose-volume predictions derived from a database of standardized Pareto-optimal plans were compared with those derived from clinical plans manually designed by various planners. Dose-volume predictions from the Pareto plan database were significantly lower overall than those from the clinical plan database, without compromising achievability. Copyright © 2018 Elsevier Inc. All rights reserved.
An Adaptive Staggered Dose Design for a Normal Endpoint.
Wu, Joseph; Menon, Sandeep; Chang, Mark
2015-01-01
In a clinical trial where several doses are compared to a control, a multi-stage design that combines both the selection of the best dose and the confirmation of this selected dose is desirable. An example is the two-stage drop-the-losers or pick-the-winner design, where inferior doses are dropped after interim analysis. Selection of target dose(s) can be based on ranking of observed effects, hypothesis testing with adjustment for multiplicity, or other criteria at interim stages. A number of methods have been proposed and have made significant gains in trial efficiency. However, many of these designs started off with all doses with equal allocation and did not consider prioritizing the doses using existing dose-response information. We propose an adaptive staggered dose procedure that allows explicit prioritization of doses and applies error spending scheme that favors doses with assumed better responses. This design starts off with only a subset of the doses and adaptively adds new doses depending on interim results. Using simulation, we have shown that this design performs better in terms of increased statistical power than the drop-the-losers design given strong prior information of dose response.
The dosimetric effects of photon energy on the quality of prostate volumetric modulated arc therapy.
Mattes, Malcolm D; Tai, Cyril; Lee, Alvin; Ashamalla, Hani; Ikoro, N C
2014-01-01
Studies comparing the dosimetric effects of high- and low-energy photons to treat prostate cancer using 3-dimensional conformal and intensity modulated radiation therapy have yielded mixed results. With the advent of newer radiation delivery systems like volumetric modulated arc therapy (VMAT), the impact of changing photon energy is readdressed. Sixty-five patients treated for prostate cancer at our institution from 2011 to 2012 underwent CT simulation. A target volume encompassing the prostate and entire seminal vesicles was treated to 50.4 Gy, followed by a boost to the prostate and proximal seminal vesicles to a total dose of 81 Gy. The VMAT plans were generated for 6-MV and 10-MV photons under identical optimization conditions using the Eclipse system version 8.6 (Varian Medical Systems, Palo Alto, CA). The analytical anisotropic algorithm was used for all dose calculations. Plans were normalized such that 98% of the planning target volume (PTV) received 100% of the prescribed dose. Dose-volumetric data from the treatment planning system was recorded for both 6-MV and 10-MV plans, which were compared for both the entire cohort and subsets of patients stratified according to the anterior-posterior separation. Plans using 10-MV photons had statistically significantly lower relative integral dose (4.1%), gradient measure (4.1%), skin Dmax (16.9%), monitor units (13.0%), and bladder V(30) (3.1%) than plans using 6-MV photons (P < .05). There was no difference in rectal dose, high-dose-region bladder dose, PTV coverage, or conformity index. The benefit of 10-MV photons was more pronounced for thicker patients (anterior-posterior separation >21 cm) for most parameters, with statistically significant differences in bladder V(30), bladder V(65), integral dose, conformity index, and monitor units. The main dosimetric benefits of 10-MV as compared with 6-MV photons are seen in thicker patients, though for the entire cohort 10-MV plans resulted in a lower integral dose, gradient measure, skin Dmax, monitor units, and bladder V(30), possibly at the expense of higher rectum V(81). Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Meco, Basak Ceyda; Bermede, Onat; Vural, Cagil; Cakmak, Atil; Alanoglu, Zekeriyya; Alkis, Neslihan
2016-01-01
The aim of this study was to compare the effects of two different doses of intrathecal morphine on postoperative analgesia, postoperative first mobilization and urination times and the severity of side effects. After Institutional Ethical Committee approval, 48 ASA I-II patients were enrolled in this randomized double-blinded study. Spinal anesthesia was performed with 0.1mg (Group I, n=22) or 0.4mg (Group II, n=26) ITM in addition to 7.5mg heavy bupivacaine. The first analgesic requirement, first mobilization and voiding times, and postoperative side effects were recorded. Statistical analyses were performed using SPSS 15.0 and p<0.05 was considered as statistically significant. The numeric data were analyzed by the t-test and presented as mean±SD. Categorical data were analyzed with the chi-square test and expressed as number of patients and percentage. Demographic data were similar among groups. There were no differences related to postoperative pain, first analgesic requirements, and first mobilization and first voiding times. The only difference between two groups was the vomiting incidence. In Group II 23% (n=6) of the patients had vomiting during the first postoperative 24h compared to 0% in Group I (p=0.025). For inguinal hernia repairs, the dose of 0.1mg of ITM provides comparable postoperative analgesia with a dose of 0.4mg, with significantly lower vomiting incidence when combined with low dose heavy bupivacaine. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Meco, Basak Ceyda; Bermede, Onat; Vural, Cagil; Cakmak, Atil; Alanoglu, Zekeriyya; Alkis, Neslihan
2016-01-01
The aim of this study was to compare the effects of two different doses of intrathecal morphine on postoperative analgesia, postoperative first mobilization and urination times and the severity of side effects. After Institutional Ethical Committee approval, 48 ASA I-II patients were enrolled in this randomized double-blinded study. Spinal anesthesia was performed with 0.1mg (Group I, n=22) or 0.4mg (Group II, n=26) ITM in addition to 7.5mg heavy bupivacaine. The first analgesic requirement, first mobilization and voiding times, and postoperative side effects were recorded. Statistical analyses were performed using SPSS 15.0 and p<0.05 was considered as statistically significant. The numeric data were analyzed by the t-test and presented as mean±SD. Categorical data were analyzed with the chi-square test and expressed as number of patients and percentage. Demographic data were similar among groups. There were no differences related to postoperative pain, first analgesic requirements, and first mobilization and first voiding times. The only difference between two groups was the vomiting incidence. In Group II 23% (n=6) of the patients had vomiting during the first postoperative 24h compared to 0% in Group I (p=0.025). For inguinal hernia repairs, the dose of 0.1mg of ITM provides comparable postoperative analgesia with a dose of 0.4mg, with significantly lower vomiting incidence when combined with low dose heavy bupivacaine. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Theunissen, E L; Vermeeren, A; van Oers, A C M; van Maris, I; Ramaekers, J G
2004-02-01
Mequitazine is a so-called 'non-sedative' second-generation antihistamine even though it has never been firmly established that this drug's sedative potential actually differs from that of the 'sedative' first-generation antihistamines. The present study compares the sedative effects of three doses of mequitazine on actual driving, psychomotor performance and memory with those of a first- and a second-generation antihistamine. Eighteen healthy volunteers received on separate days a single dose of 5, 10 and 15 mg mequitazine, 10 mg cetirizine, 6 mg dexchlorpheniramine and placebo. Drug effects were assessed using two actual driving tests (highway-driving test and car-following test), cognitive and psychometric tests (tracking, divided attention, memory, reasoning and critical flicker fusion), pupil size and questionnaires. Highway-driving data revealed an overall effect of Treatment on the standard deviation of lateral position (SDLP). Dexchlorpheniramine impaired driving performance as indicated by a significant rise in SDLP. Mequitazine significantly increased SDLP in a dose-related manner, but the separate dose effects failed to reach statistical significance. Divided attention performance was also affected by Treatment. Reaction time (RT) during mequitazine treatments increased in a dose-related manner and significantly differed from placebo at the highest dose. Subjects reported to be less alert after treatment with dexchlorpheniramine. Cetirizine did not affect performance in any of the tasks. It was concluded that mequitazine is mildly sedating. The effects of mequitazine are comparable to those of other second-generation antihistamines, in that it causes mild driving impairment, particularly at higher doses.
Rösler, Michael; Anand, Ravi; Cicin-Sain, Ana; Gauthier, Serge; Agid, Yves; Dal-Bianco, Peter; Stähelin, Hannes B; Hartman, Richard; Gharabawi, Marguirguis
1999-01-01
Objectives To assess the effects of rivastigmine on the core domains of Alzheimer’s disease. Design Prospective, randomised, multicentre, double blind, placebo controlled, parallel group trial. Patients received either placebo, 1-4 mg/day (lower dose) rivastigmine, or 6-12 mg/day (higher dose) rivastigmine. Doses were increased in one of two fixed dose ranges (1-4 mg/day or 6-12 mg/day) over the first 12 weeks with a subsequent assessment period of 14 weeks. Setting 45 centres in Europe and North America. Participants 725 patients with mild to moderately severe probable Alzheimer’s disease diagnosed according to the Diagnostic and Statistical Manual of Mental Disorders, fourth edition, and the criteria of the National Institute of Neurological and Communicative Disorders and Stroke and the Alzheimer’s Disease and Related Disorders Association. Outcome measures Cognitive subscale of the Alzheimer’s disease assessment scale, rating on the clinician interview based impression of change incorporating caregiver information scale, and the progressive deterioration scale. Results At the end of the study cognitive function had deteriorated among those in the placebo group. Scores on the Alzheimer’s disease assessment scale improved in patients in the higher dose group when compared with patients taking placebo (P<0.05). Significantly more patients in the higher dose group had improved by 4 points or more than had improved in the placebo group (24% (57/242) v 16% (39/238)). Global function as rated by the clinician interview scale had significantly improved among those in the higher dose group compared with those taking placebo (P<0.001), and significantly more patients in the higher dose group showed improvement than did in the placebo group (37% (80/219) v 20% (46/230)). Mean scores on the progressive deterioration scale improved from baseline in patients in the higher dose group but fell in the placebo group. Adverse events were predominantly gastrointestinal, of mild to moderate severity, transient, and occurred mainly during escalation of the dose. 23% (55/242) of those in the higher dose group, 7% (18/242) of those in the lower dose group, and 7% (16/239) of those in the placebo group discontinued treatment because of adverse events. Conclusions Rivastigmine is well tolerated and effective. It improves cognition, participation in activities of daily living, and global evaluation ratings in patients with mild to moderately severe Alzheimer’s disease. This is the first treatment to show compelling evidence of efficacy in a predominantly European population. Key messagesIn a 6 month trial rivastigmine was effective in treating the core cognitive and functional symptoms of patients with mild to moderate Alzheimer’s diseaseRivastigmine at doses of 6-12 mg/day produces clinically relevant and statistically significant improvements in cognitive and global assessments, and in activities of daily livingThe effects of rivastigmine are dose dependentRivastigmine was well tolerated in this population of elderly patients PMID:10066203
A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent
The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculatingmore » a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long term process performance indices (P{sub p}, P{sub pk}, and P{sub pm}) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).« less
A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC).
Gérard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, François; Aletti, Pierre
2009-04-01
The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short-term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center (+/- 4% of deviation between the calculated and measured doses) by calculating a control process capability (C(pc)) index. The C(pc) index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short-term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long-term process performance indices (P(p), P(pk), and P(pm)) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).
Applying the technique of volume-modulated arc radiotherapy to upper esophageal carcinoma.
Ma, Pan; Wang, Xiaozhen; Xu, Yingjie; Dai, Jianrong; Wang, Luhua
2014-05-08
This study aims to evaluate the possibility of using the technique of volume-modulated arc therapy (VMAT) to combine the advantages of simplified intensity-modulated radiation therapy (sIMRT) with that of regular intensity-modulated radiation therapy (IMRT) in upper esophageal cancer. Ten patients with upper esophageal carcinoma were randomly chosen in this retrospective study. sIMRT, IMRT, and VMAT plans were generated to deliver 60 Gy in 30 fractions to the planning target volume (PTV). For each patient, with the same clinical requirements (target dose prescription, and dose/dose-volume constraints to organs at risk (OARs)), three plans were designed for sIMRT (five equispaced coplanar beams), IMRT (seven equispaced coplanar beams), and VMAT (two complete arcs). Comparisons were performed for dosimetric parameters of PTV and of OARs (lungs, spinal cord PRV, heart and normal tissue (NT)). All the plans were delivered to a phantom to evaluate the treatment time. The Wilcoxon matched-pairs, signed-rank test was used for intragroup comparison. For all patients, compared to sIMRT plans, VMAT plans statistically provide: a) significant improvement in HI and CI for PTV; b) significant decrease in delivery time, lung V20, MLD, heart V30 and spinal cord PRV D1cc; c) significant increase in NT V5; and d) no significant reduction in lung V5, V10, and heart MD. For all patients, compared to IMRT plans, VMAT plans statistically provide: a) significant improvement in CI for PTV; b) significant decrease in delivery time, lung V20, MLD, NT and spinal cord PRV D1cc; c) significant increase in NT V5; and d) no significant reduction in HI for PTV, lung V5, V10, heart V30 and heart MD. For patients with upper esophageal carcinoma, using VMAT significantly reduces the delivery time and the dose to the lungs compared with IMRT, and consequently saves as much treatment time as sIMRT. Considering those significant advantages, compared to sIMRT and IMRT, VMAT is the first choice of radiotherapy techniques for upper esophageal carcinoma.
Glatzel, J
1978-08-04
161 patients with the chronic organic brain syndrome (average age 64 years) were treated with various oral doses of Pyritinol for various periods of time. Statistical analysis of the data by means of "Konfigurationsfrequenzanalyse" showed that the success rate of treatment increases significantly with increasing dose and duration of the treatment. This means that the recommended daily dose should be exceeded if - for example at the start of treatment and in severe cases or in hospitalized patients - there is no immediate clear improvement in the condition. From the point of view of method this study shows that a retrospective analysis of a group of patients treated in a clinic can also provide interesting results and appropriately supplement controlled studies.
Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A
2018-06-01
Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Randomized study of surgical prophylaxis in immunocompromised hosts.
Lopes, D R; Peres, M P S M; Levin, A S
2011-02-01
Although prophylaxis is current practice, there are no randomized controlled studies evaluating preoperative antimicrobial prophylaxis in dental procedures in patients immunocompromised by chemotherapy or organ transplants. To evaluate prophylaxis in dental-invasive procedures in patients with cancer or solid organ transplants, 414 patients were randomized to receive one oral 500-mg dose 2 hours before the procedure (1-dose group) or a 500-mg dose 2 hours before the procedure and an additional dose 8 hours later (2-dose group). Procedures were exodontia or periodontal scaling/root planing. Follow-up was 4 weeks. No deaths or surgical site infections occurred. Six patients (1.4%) presented with use of pain medication > 3 days or hospitalization during follow-up: 4 of 207 (2%) in the 1-dose group and 2 of 207 (1%) in the 2-dose group (relative risk, 2.02; 95% confidence interval, 0.37-11.15). In conclusion, no statistically significant difference occurred in outcome using 1 or 2 doses of prophylactic amoxicillin for invasive dental procedures in immunocompromised patients.
High-order noise analysis for low dose iterative image reconstruction methods: ASIR, IRIS, and MBAI
NASA Astrophysics Data System (ADS)
Do, Synho; Singh, Sarabjeet; Kalra, Mannudeep K.; Karl, W. Clem; Brady, Thomas J.; Pien, Homer
2011-03-01
Iterative reconstruction techniques (IRTs) has been shown to suppress noise significantly in low dose CT imaging. However, medical doctors hesitate to accept this new technology because visual impression of IRT images are different from full-dose filtered back-projection (FBP) images. Most common noise measurements such as the mean and standard deviation of homogeneous region in the image that do not provide sufficient characterization of noise statistics when probability density function becomes non-Gaussian. In this study, we measure L-moments of intensity values of images acquired at 10% of normal dose and reconstructed by IRT methods of two state-of-art clinical scanners (i.e., GE HDCT and Siemens DSCT flash) by keeping dosage level identical to each other. The high- and low-dose scans (i.e., 10% of high dose) were acquired from each scanner and L-moments of noise patches were calculated for the comparison.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McEachen, James C., E-mail: james.mceachen2@gmail.com; Leng, Shuai; Atwell, Thomas D.
IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the meanmore » DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.« less
Effect of water extract of Psidium guajava leaves on alloxan-induced diabetic rats.
Mukhtar, H M; Ansari, S H; Ali, M; Naved, T; Bhat, Z A
2004-09-01
A water extract of Psidium guajava leaves was screened for hypoglycemic activity on alloxan-induced diabetic rats. In both acute and sub-acute tests, the water extract, at an oral dose of 250 mg/kg, showed statistically significant hypoglycemic activity.
Respiratory effects of diesel exhaust in salt miners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamble, J.F.; Jones, W.G.
1983-09-01
The respiratory health of 259 white males working at 5 salt (NaCl) mines was assessed by questionnaire, chest radiographs, and air and He-O/sup 2/ spirometry. Response variables were symptoms, pneumoconiosis, and spirometry. Predictor variables included age, height, smoking, mine, and tenure in diesel-exposed jobs. The purpose was to assess the association of response measures of respiratory health with exposure to diesel exhaust. There were only 2 cases of Grade 1 pneumoconiosis, so no further analysis was done. Comparisons within the study population showed a statistically significant dose-related association of phlegm and diesel exposure. There was a nonsignificant trend for coughmore » and dyspnea, and no association with spirometry. Age- and smoking-adjusted rates of cough, phlegm, and dyspnea were 145, 159, and 93% of an external comparison population. Percent predicted flow rates showed statistically significant reductions, but the reductions were small and there were no dose-response relations. Percent predicted FEV1 and FVC were about 96% of predicted.« less
Barber, J; McNulty, J P
2012-10-01
To measure the intensity and distribution of scatter radiation received by a restrainer in veterinary radiography including the intensity of scatter radiation passing through lead protective devices at pre-defined positions. Anthropomorphic phantoms and a Labrador dog cadaver were used to simulate a restrainer and patient. Scatter dose measurements were recorded at the position of the restraining hands, thyroid, breast and gonads with and without appropriate lead protection. This was repeated for the eight most common projections as identified in an initial retrospective survey. Manual restraint of an animal for a radiographic procedure will result in a scatter radiation dose to the restrainer. The level of radiation dose varies between body regions and between projections. The use of appropriate lead protection resulted in statistically significant dose reductions to all body regions with maximum scatter dose reductions between 93 and 100%. While the doses recorded were small (μGy) in terms of associated risk, they are nonetheless cumulative which can result in a more significant dose. Therefore manual restraint should be avoided and forms of immobilisation should be used such as mechanical means, sedation or general anaesthesia. However, if completely necessary both principles of distance and adequate lead protection should be employed. © 2012 British Small Animal Veterinary Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaur, H; Kumar, S; Sarkar, B
Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cmmore » in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.« less
Woodford, Katrina; Panettieri, Vanessa; Ruben, Jeremy D; Senthi, Sashendra
2016-05-01
Intensity modulated radiotherapy (IMRT) is routinely utilized in the treatment of locally advanced non-small cell lung cancer (NSCLC). RTOG 0617 found that overall survival was impacted by increased low (5 Gy) and intermediate (30 Gy) cardiac doses. We evaluated the impact of esophageal-sparing IMRT on cardiac doses with and without the heart considered in the planning process and predicted toxicity compared to 3D-conventional radiotherapy (3DCRT). Ten consecutive patients with N2 Stage III NSCLC treated to 60 Gy in 30 fractions, between February 2012 and September 2014, were evaluated. For each patient, 3DCRT and esophageal-sparing IMRT plans were generated. IMRT plans were then created with and without the heart considered in the optimization process. To compare plans, the dose delivered to 95% and 99% of the target (D95% and D99%), and doses to the esophagus, lung and heart were compared by determining the volume receiving X dose (VXGy) and the normal tissue complication probability (NTCP) calculated. IMRT reduced maximum esophagus dose to below 60 Gy in all patients and produced significant reductions to V50Gy, V40Gy and esophageal NTCP. The cost of this reduction was a non-statistically, non-clinically significant increase in low dose (5 Gy) lung exposure that did not worsen lung NTCP. IMRT plans produced significant cardiac sparing, with the amount of improvement correlating to the amount of heart overlapping with the target. When included in plan optimization, for selected patients further sparing of the heart and improvement in heart NTCP was possible. Esophageal-sparing IMRT can significantly spare the heart even if it is not considered in the optimization process. Further sparing can be achieved if plan optimization constrains low and intermediate heart doses, without compromising lung doses.
Deinzer, Christoph K W; Danova, Daniela; Kleb, Beate; Klose, Klaus J; Heverhagen, Johannes T
2014-01-01
The objective of this work was to examine differences in DNA double-strand break induction in peripheral blood lymphocytes after in vitro X-ray irradiation between iodinated contrast agents. Four different iodinated X-ray contrast agents--three of them with two different iodine concentrations--and mannitol (negative control; concentration of 150 mg mannitol per ml blood) were pipetted into blood samples so that there was a concentration of 0, 7.5 or 15 mg of iodine per ml blood in the samples. Negative controls without contrast medium (0 mg of iodine per ml blood) were also processed for every irradiation dose. The tubes were exposed to 0, 20 or 500 mGy in vitro X-ray irradiation. After that, the lymphocytes were separated by using density-gradient centrifugation. Fluorescence microscopy was applied to determine the average number of γH2AX-foci per lymphocyte in the presence or absence of different contrast media or mannitol. Differences in the number of γH2AX-foci were statistically analysed by one-way ANOVA and post-hoc Tukey's honestly significant difference test. Iodinated contrast agents led to a statistically significant increase in DNA double-strand breaks after in vitro irradiation. This effect increased statistically significant with rising radiation dose and appeared independent of the contrast agent used (iopromid, iodixanol, iomeprol, iopamidol). A statistically significant difference in DNA damage between the different tested contrast agents was not found. Therefore, the increase in DNA double-strand breaks depends solely on the amount of iodine applied. For evaluation of clinical consequences, our findings could be tested in further animal studies. Copyright © 2014 John Wiley & Sons, Ltd.
Andryskowski, G; Chojnowska-Jezierska, J; Broncel, M; Barylski, M; Banach, M
2008-01-01
The aim of the study was to estimate the effect of calcium supplementation on cholesterol concentrations in patients with hyperlipidaemia and previous viral hepatitis. The study comprised 43 patients, aged 28 to 82 years (21 with type 2 hyperlipidaemia). The control group included 22 healthy subjects. After four weeks of a hypolipaemic diet (wash-out period), the patients with type 2 hyperlipidaemia were recruited to a group administered a complex preparation containing 170 mg of calcium lactate and 60 mg of vitamin C (Calcium C, Polfa-Lodz SA, Poland) at a dose of one tablet three times a day. After four weeks of active therapy, the concentration of total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C) and triglycerides (TG) decreased by 4, 6 and 8%, respectively. Statistical significance was obtained for only TC (p = 0.03) when comparing the group of patients with hypercholesterolaemia before and after the therapy with the calcium preparation. A statistically insignificant increase of high-density lipoprotein cholesterol (HDL-C) of 1% was observed. Within the four-week period of calcium supplementation at a dose of 510 mg/24 h, the total concentration of calcium decreased by 3%, whereas the concentration of ionised calcium increased by 7%. None of the obtained values was of statistical significance. In patients with type 2 hyperlipidaemia and previous viral hepatitis, a four-week supplementation of calcium in a calcium lactate preparation beneficially modified the lipid profile. I t statistically significantly decreased the total cholesterol concentration by 4% (p = 0.03), did not cause any significant changes in serum calcium concentration, was well tolerated and did not induce any side effects.
Racial background is a determinant factor in the maintenance dosage of warfarin.
Gan, Gin Gin; Teh, Alan; Goh, Kim Yen; Chong, Heng Thay; Pang, Kang Wah
2003-07-01
Warfarin is a drug commonly used in the prevention of thromboembolic events. There have been reports suggesting that racial background may influence warfarin dose requirements. Malaysia is a multiracial country in which there are 3 major races, Malay, Chinese, and Indian. We examined 100 patients from our hospital on stable maintenance doses of warfarin, with international normalized ratio (INR) of 2.0 to 3.5. We found that the mean warfarin dose for Indian patients (n = 19) was 6.9 mg, for Chinese patients (n = 55) was 3.6 mg, and for Malay patients (n = 26) was 3.2 mg. The results showed that the Indian patients required a statistically significantly higher warfarin dose than did patients of the other 2 races (P < .0005). Age was also found to affect the daily warfarin maintenance dose.
Lievens, Yolande; Nulens, An; Gaber, Mousa Amr; Defraene, Gilles; De Wever, Walter; Stroobants, Sigrid; Van den Heuvel, Frank
2011-05-01
To evaluate the potential for dose escalation with intensity-modulated radiotherapy (IMRT) in positron emission tomography-based radiotherapy planning for locally advanced non-small-cell lung cancer (LA-NSCLC). For 35 LA-NSCLC patients, three-dimensional conformal radiotherapy and IMRT plans were made to a prescription dose (PD) of 66 Gy in 2-Gy fractions. Dose escalation was performed toward the maximal PD using secondary endpoint constraints for the lung, spinal cord, and heart, with de-escalation according to defined esophageal tolerance. Dose calculation was performed using the Eclipse pencil beam algorithm, and all plans were recalculated using a collapsed cone algorithm. The normal tissue complication probabilities were calculated for the lung (Grade 2 pneumonitis) and esophagus (acute toxicity, grade 2 or greater, and late toxicity). IMRT resulted in statistically significant decreases in the mean lung (p <.0001) and maximal spinal cord (p = .002 and 0005) doses, allowing an average increase in the PD of 8.6-14.2 Gy (p ≤.0001). This advantage was lost after de-escalation within the defined esophageal dose limits. The lung normal tissue complication probabilities were significantly lower for IMRT (p <.0001), even after dose escalation. For esophageal toxicity, IMRT significantly decreased the acute NTCP values at the low dose levels (p = .0009 and p <.0001). After maximal dose escalation, late esophageal tolerance became critical (p <.0001), especially when using IMRT, owing to the parallel increases in the esophageal dose and PD. In LA-NSCLC, IMRT offers the potential to significantly escalate the PD, dependent on the lung and spinal cord tolerance. However, parallel increases in the esophageal dose abolished the advantage, even when using collapsed cone algorithms. This is important to consider in the context of concomitant chemoradiotherapy schedules using IMRT. Copyright © 2011 Elsevier Inc. All rights reserved.
The Hanford Thyroid Disease Study: an alternative view of the findings.
Hoffman, F Owen; Ruttenber, A James; Apostoaei, A Iulian; Carroll, Raymond J; Greenland, Sander
2007-02-01
The Hanford Thyroid Disease Study (HTDS) is one of the largest and most complex epidemiologic studies of the relation between environmental exposures to I and thyroid disease. The study detected no dose-response relation using a 0.05 level for statistical significance. The results for thyroid cancer appear inconsistent with those from other studies of populations with similar exposures, and either reflect inadequate statistical power, bias, or unique relations between exposure and disease risk. In this paper, we explore these possibilities, and present evidence that the HTDS statistical power was inadequate due to complex uncertainties associated with the mathematical models and assumptions used to reconstruct individual doses. We conclude that, at the very least, the confidence intervals reported by the HTDS for thyroid cancer and other thyroid diseases are too narrow because they fail to reflect key uncertainties in the measurement-error structure. We recommend that the HTDS results be interpreted as inconclusive rather than as evidence for little or no disease risk from Hanford exposures.
Van Stan, Jarrad H.; Mehta, Daryush D.; Zeitels, Steven M.; Burns, James A.; Barbu, Anca M.; Hillman, Robert E.
2015-01-01
Objectives Clinical management of phonotraumatic vocal fold lesions (nodules, polyps) is based largely on assumptions that abnormalities in habitual levels of sound pressure level (SPL), fundamental frequency (f0), and/or amount of voice use play a major role in lesion development and chronic persistence. This study used ambulatory voice monitoring to evaluate if significant differences in voice use exist between patients with phonotraumatic lesions and normal matched controls. Methods Subjects were 70 adult females: 35 with vocal fold nodules or polyps and 35 age-, sex-, and occupation-matched normal individuals. Weeklong summary statistics of voice use were computed from anterior neck surface acceleration recorded using a smartphone-based ambulatory voice monitor. Results Paired t-tests and Kolmogorov-Smirnov tests resulted in no statistically significant differences between patients and matched controls regarding average measures of SPL, f0, vocal dose measures, and voicing/voice rest periods. Paired t-tests comparing f0 variability between the groups resulted in statistically significant differences with moderate effect sizes. Conclusions Individuals with phonotraumatic lesions did not exhibit differences in average ambulatory measures of vocal behavior when compared with matched controls. More refined characterizations of underlying phonatory mechanisms and other potentially contributing causes are warranted to better understand risk factors associated with phonotraumatic lesions. PMID:26024911
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, C; Dixon, S
Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kermamore » (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.« less
Böning, G; Schäfer, M; Grupp, U; Kaul, D; Kahn, J; Pavel, M; Maurer, M; Denecke, T; Hamm, B; Streitparth, F
2015-08-01
To investigate whether dose reduction via adaptive statistical iterative reconstruction (ASIR) affects image quality and diagnostic accuracy in neuroendocrine tumor (NET) staging. A total of 28 NET patients were enrolled in the study. Inclusion criteria were histologically proven NET and visible tumor in abdominal computed tomography (CT). In an intraindividual study design, the patients underwent a baseline CT (filtered back projection, FBP) and follow-up CT (ASIR 40%) using matched scan parameters. Image quality was assessed subjectively using a 5-grade scoring system and objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs). Applied volume computed tomography dose index (CTDIvol) of each scan was taken from the dose report. ASIR 40% significantly reduced CTDIvol (10.17±3.06mGy [FBP], 6.34±2.25mGy [ASIR] (p<0.001) by 37.6% and significantly increased CNRs (complete tumor-to-liver, 2.76±1.87 [FBP], 3.2±2.32 [ASIR]) (p<0.05) (complete tumor-to-muscle, 2.74±2.67 [FBP], 4.31±4.61 [ASIR]) (p<0.05) compared to FBP. Subjective scoring revealed no significant changes for diagnostic confidence (5.0±0 [FBP], 5.0±0 [ASIR]), visibility of suspicious lesion (4.8±0.5 [FBP], 4.8±0.5 [ASIR]) and artifacts (5.0±0 [FBP], 5.0±0 [ASIR]). ASIR 40% significantly decreased scores for noise (4.3±0.6 [FBP], 4.0±0.8 [ASIR]) (p<0.05), contrast (4.4±0.6 [FBP], 4.1±0.8 [ASIR]) (p<0.001) and visibility of small structures (4.5±0.7 [FBP], 4.3±0.8 [ASIR]) (p<0.001). In clinical practice ASIR can be used to reduce radiation dose without sacrificing image quality and diagnostic confidence in staging CT of NET patients. This may be beneficial for patients with frequent follow-up and significant cumulative radiation exposure. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Lindner, M; Gramer, G; Garbade, S F; Burgard, P
2009-08-01
Tetrahydrobiopterin (BH(4)) cofactor loading is a standard procedure to differentiate defects of BH(4) metabolism from phenylalanine hydroxylase (PAH) deficiency. BH(4) responsiveness also exists in PAH-deficient patients with high residual PAH activity. Unexpectedly, single cases with presumed nil residual PAH activity have been reported to be BH(4) responsive, too. BH(4) responsiveness has been defined either by a >or=30% reduction of blood Phe concentration after a single BH(4) dose or by a decline greater than the individual circadian Phe level variation. Since both methods have methodological disadvantages, we present a model of statistical process control (SPC) to assess BH(4) responsiveness. Phe levels in 17 adult PKU patients of three phenotypic groups off diet were compared without and with three different single oral dosages of BH(4) applied in a double-blind randomized cross-over design. Results are compared for >or=30% reduction and SPC. The effect of BH(4) by >or=30% reduction was significant for groups (p < 0.01) but not for dose (p = 0.064), with no interaction of group with dose (p = 0.24). SPC revealed significant effects for group (p < 0.01) and the interaction for group with dose (p < 0.05) but not for dose alone (p = 0.87). After one or more loadings, seven patients would be judged to be BH(4) responsive either by the 30% criterion or by the SPC model, but only three by both. Results for patients with identical PAH genotype were not very consistent within (for different BH(4) doses) and between the two models. We conclude that a comparison of protein loadings without and with BH(4) combined with a standardized procedure for data analysis and decision would increase the reliability of diagnostic results.
Ensor, Mark; Williams, Jarrod; Smith, Rebecca; Banfield, Amy; Lodder, Robert A
2014-10-01
The primary objective of this study was to evaluate the safety and the effect of D-tagatose on the glycemic control of subjects with type 2 diabetes as determined by HbA 1c levels at the end of 6 months of therapy using the subject's own baseline HbA 1c level as a comparator. The determination of the minimal dose required to cause a statistically significant reduction in HbA 1c was of particular interest. Eight weeks after screening, the qualifying subjects were randomized to receive one of three doses of D-tagatose: 2.5 g TID, 5.0 g TID or 7.5 g TID. Blood levels of HbA 1c , fasting blood glucose concentrations, plasma lipids, changes in body weight, changes in body mass index, and change in insulin levels were checked at each study visit and at the end of the study. Treatment success, as measured by the reduction of HbA 1c , was greatest for the 7.5 g D-tagatose dose group, although the difference between the treatments was not statistically significant. For fasting glucose, only the 7.5 g dosage group exhibited reductions from baseline at the 3- and 6-month time points. Mean body weights reduced in a dose-response fashion, with the 5.0 g and the 7.5 g D-tagatose doses providing the greatest reductions. D-tagatose at dosages of 2.5 g, 5.0 g, and 7.5 g TID for six months were well tolerated by this subject population. D-tagatose at 5.0 g TID was the minimal dose required to reduce HbA 1c . D-tagatose at 7.5 g TID provided the greatest effect in most measured efficacy parameters.
Ensor, Mark; Williams, Jarrod; Smith, Rebecca; Banfield, Amy; Lodder, Robert A.
2014-01-01
The primary objective of this study was to evaluate the safety and the effect of D-tagatose on the glycemic control of subjects with type 2 diabetes as determined by HbA1c levels at the end of 6 months of therapy using the subject’s own baseline HbA1c level as a comparator. The determination of the minimal dose required to cause a statistically significant reduction in HbA1c was of particular interest. Eight weeks after screening, the qualifying subjects were randomized to receive one of three doses of D-tagatose: 2.5 g TID, 5.0 g TID or 7.5 g TID. Blood levels of HbA1c, fasting blood glucose concentrations, plasma lipids, changes in body weight, changes in body mass index, and change in insulin levels were checked at each study visit and at the end of the study. Treatment success, as measured by the reduction of HbA1c, was greatest for the 7.5 g D-tagatose dose group, although the difference between the treatments was not statistically significant. For fasting glucose, only the 7.5 g dosage group exhibited reductions from baseline at the 3- and 6-month time points. Mean body weights reduced in a dose-response fashion, with the 5.0 g and the 7.5 g D-tagatose doses providing the greatest reductions. D-tagatose at dosages of 2.5 g, 5.0 g, and 7.5 g TID for six months were well tolerated by this subject population. D-tagatose at 5.0 g TID was the minimal dose required to reduce HbA1c. D-tagatose at 7.5 g TID provided the greatest effect in most measured efficacy parameters. PMID:25580449
DOE Office of Scientific and Technical Information (OSTI.GOV)
Epstein, D; Shekel, E; Levin, D
Purpose: The purpose of this work was to verify the accuracy of the dose distribution along the field junction in a half beam irradiation technique for breast cancer patients receiving radiation to the breast or chest wall (CW) and the supraclavicular LN region for both free breathing and deep inspiration breath hold (DIBH) technique. Methods: We performed in vivo measurements for nine breast cancer patients receiving radiation to the breast/CW and to the supraclavicular LN region. Six patients were treated to the left breast/CW using DIBH technique and three patients were treated to the right breast/CW in free breath. Wemore » used five microMOSFET dosimeters: three located along the field junction, one located 1 cm above the junction and the fifth microMOSFET located 1 cm below the junction. We performed consecutive measurements over several days for each patient and compared the measurements to the TPS calculation (Eclipse, Varian™). Results: The calculated and measured doses along the junction were 0.97±0.08 Gy and 1.02±0.14 Gy, respectively. Above the junction calculated and measured doses were 0.91±0.08 Gy and 0.98±0.09 Gy respectively, and below the junction calculated and measured doses were 1.70±0.15 Gy and 1.61±0.09 Gy, respectively. All differences were not statistically significant. When comparing calculated and measured doses for DIBH patients only, there was still no statistically significant difference between values for all dosimeter locations. Analysis was done using the Mann-Whitney Rank-Sum Test. Conclusion: We found excellent correlation between calculated doses from the TPS and measured skin doses at the junction of several half beam fields. Even for the DIBH technique, where there is more potential for variance due to depth of breath, there is no over or underdose along the field junction. This correlation validates the TPS, as well an accurate, reproducible patient setup.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, T; Lin, X; Yin, Y
Purpose: To compare the dosimetric differences among fixed field intensity-modulated radiotherapy (IMRT) and double-arc volumetricmodulated arc therapy (VMAT) plans with simultaneous integrated boost in rectal cancer. Methods: Ten patients with rectal cancer previously treated with IMRT were included in this analysis. For each patient, two treatment techniques were designed for each patient: the fixed 7 fields IMRT and double-arc VMAT with RapidArc technique. The treatment plan was designed to deliver in one process with simultaneous integrated boost (SIB). The prescribed doses to the planning target volume of the subclinical disease (PTV1) and the gross disease (PTV2) were 45 Gy andmore » 55 Gy in 25 fractions, respectively. The dose distribution in the target, the dose to the organs at risk, total MU and the delivery time in two techniques were compared to explore the dosimetric differences. Results: For the target dose and homogeneity in PTV1 and PTV2, no statistically differences were observed in the two plans. VMAT plans showed a better conformity in PTV1. VMAT plans reduced the mean dose to bladder, small bowel, femur heads and iliac wings. For iliac wings, VMAT plans resulted in a statistically significant reduction in irradiated volume of 15 Gy, 20 Gy, 30 Gy but increased the 10 Gy irradiated volume. VMAT plans reduced the small bowel irradiated volume of 20 Gy and 30 Gy. Compared with IMRT plans, VMAT plans showed a significant reduction of monitor units by nearly 30% and reduced treatment time by an average of 70% Conclusion: Compared to IMRT plans, VMAT plans showed the similar target dose and reduced the dose of the organs at risk, especially for small bowel and iliac wings. For rectal cancer, VMAT with simultaneous integrated boost can be carried out with high quality and efficiency.« less
Lundborg, Christopher; Bjersing, Jan; Dahm, Peter; Hansson, Elisabeth; Biber, Björn
2015-01-01
Introduction: This randomized, cross-over, double-blind, controlled study of continuous intrathecal morphine administration in patients with severe, long-term pain addresses whether the supplementation of low doses of naloxone in this setting is associated with beneficial clinical effects. Methods: All of the study subjects (n=11) provided informed consent and were recruited from a subset of patients who were already undergoing long-term treatment with continuous intrathecal morphine because of difficult-to-treat pain. The patients were (in a randomized order) also given intrathecal naloxone (40 ng/24 h or 400 ng/24 h). As control, the patients’ ordinary dose of morphine without any additions was used. The pain (Numeric Rating Scale, NRS) during activity, perceived quality of sleep, level of activity, and quality of life as well as the levels of several proinflammatory and anti-inflammatory cytokines in the blood were assessed. The prestudy pain (NRS during activity) in the study group ranged from 3 to 10. Results: A total of 64% of the subjects reported improved quality of sleep during treatment with naloxone at a dose of 40 ng per 24 hours as compared with 9% with sham treatment (P=0.024). Although not statistically significant, pain was reduced by 2 NRS steps or more during supplemental treatment with naloxone in 36% of subjects when using the 40 ng per 24 hours dose and in 18% of the subjects when using naloxone 400 ng per 24 hours dose. The corresponding percentage among patients receiving unaltered treatment was 27%. Conclusions: To conclude, the addition of an ultralow dose of intrathecal naloxone (40 ng/24 h) to intrathecal morphine infusion in patients with severe, persistent pain improved perceived quality of sleep. We were not able to show any statistically significant effects of naloxone on pain relief, level of activity, or quality of life. PMID:25629634
Dose-response effects for disease management programs on hospital utilization in Illinois Medicaid.
Berg, Gregory D; Donnelly, Shawn; Miller, Mary; Medina, Wendie; Warnick, Kathleen
2012-12-01
The objective of this study is to estimate a dose-response impact of disease management contacts on inpatient admissions. Multivariate regression analysis of panel data was used to test the hypothesis that increased disease management contacts lower the odds of an inpatient admission. Subjects were 40,452 members of Illinois' noninstitutionalized Medicaid-only aged, blind, or disabled population diagnosed with asthma, coronary artery disease, chronic obstructive pulmonary disease, diabetes, and/or heart failure. All members are also in the state's Illinois Health Connect program, a medical home strategy in place for most of the 2.4 million Illinois Medicaid beneficiaries. The statistical measure is the odds ratio, which is a measure of association between the monthly inpatient admission indicator and the number of contacts (doses) a member has had for each particular disease management intervention. Statistically significant contacts are between 8 and 12 for heart failure, between 4 and 12 contacts for diabetes, and between 8 and 13 contacts for asthma. Total inpatient savings during the study period is estimated to be $12.4 million. This study shows the dose-response pattern of inpatient utilization improvements through the number of disease management contacts.
Bianchi, C; Botta, F; Conte, L; Vanoli, P; Cerizza, L
2008-10-01
This study was undertaken to compare the biological efficacy of different high-dose-rate (HDR) and low-dose-rate (LDR) treatments of gynaecological lesions, to identify the causes of possible nonuniformity and to optimise treatment through customised calculation. The study considered 110 patients treated between 2001 and 2006 with external beam radiation therapy and/or brachytherapy with either LDR (afterloader Selectron, (137)Cs) or HDR (afterloader microSelectron Classic, (192)Ir). The treatments were compared in terms of biologically effective dose (BED) to the tumour and to the rectum (linear-quadratic model) by using statistical tests for comparisons between independent samples. The difference between the two treatments was statistically significant in one case only. However, within each technique, we identified considerable nonuniformity in therapeutic efficacy due to differences in fractionation schemes and overall treatment time. To solve this problem, we created a Microsoft Excel spreadsheet allowing calculation of the optimal treatment for each patient: best efficacy (BED(tumour)) without exceeding toxicity threshold (BED(rectum)). The efficacy of a treatment may vary as a result of several factors. Customised radiobiological evaluation is a useful adjunct to clinical evaluation in planning equivalent treatments that satisfy all dosimetric constraints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, SP; Moore, JA; Hui, X
Purpose: Database dose predictions and a commercial autoplanning engine both improve treatment plan quality in different but complimentary ways. The combination of these planning techniques is hypothesized to further improve plan quality. Methods: Four treatment plans were generated for each of 10 head and neck (HN) and 10 prostate cancer patients, including Plan-A: traditional IMRT optimization using clinically relevant default objectives; Plan-B: traditional IMRT optimization using database dose predictions; Plan-C: autoplanning using default objectives; and Plan-D: autoplanning using database dose predictions. One optimization was used for each planning method. Dose distributions were normalized to 95% of the planning target volumemore » (prostate: 8000 cGy; HN: 7000 cGy). Objectives used in plan optimization and analysis were the larynx (25%, 50%, 90%), left and right parotid glands (50%, 85%), spinal cord (0%, 50%), rectum and bladder (0%, 20%, 50%, 80%), and left and right femoral heads (0%, 70%). Results: All objectives except larynx 25% and 50% resulted in statistically significant differences between plans (Friedman’s χ{sup 2} ≥ 11.2; p ≤ 0.011). Maximum dose to the rectum (Plans A-D: 8328, 8395, 8489, 8537 cGy) and bladder (Plans A-D: 8403, 8448, 8527, 8569 cGy) were significantly increased. All other significant differences reflected a decrease in dose. Plans B-D were significantly different from Plan-A for 3, 17, and 19 objectives, respectively. Plans C-D were also significantly different from Plan-B for 8 and 13 objectives, respectively. In one case (cord 50%), Plan-D provided significantly lower dose than plan C (p = 0.003). Conclusion: Combining database dose predictions with a commercial autoplanning engine resulted in significant plan quality differences for the greatest number of objectives. This translated to plan quality improvements in most cases, although special care may be needed for maximum dose constraints. Further evaluation is warranted in a larger cohort across HN, prostate, and other treatment sites. This work is supported by Philips Radiation Oncology Systems.« less
Stambaugh, Cassandra; Nelms, Benjamin E; Dilling, Thomas; Stevens, Craig; Latifi, Kujtim; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir
2013-09-01
The effects of respiratory motion on the tumor dose can be divided into the gradient and interplay effects. While the interplay effect is likely to average out over a large number of fractions, it may play a role in hypofractionated [stereotactic body radiation therapy (SBRT)] treatments. This subject has been extensively studied for intensity modulated radiation therapy but less so for volumetric modulated arc therapy (VMAT), particularly in application to hypofractionated regimens. Also, no experimental study has provided full four-dimensional (4D) dose reconstruction in this scenario. The authors demonstrate how a recently described motion perturbation method, with full 4D dose reconstruction, is applied to describe the gradient and interplay effects during VMAT lung SBRT treatments. VMAT dose delivered to a moving target in a patient can be reconstructed by applying perturbations to the treatment planning system-calculated static 3D dose. Ten SBRT patients treated with 6 MV VMAT beams in five fractions were selected. The target motion (motion kernel) was approximated by 3D rigid body translation, with the tumor centroids defined on the ten phases of the 4DCT. The motion was assumed to be periodic, with the period T being an average from the empirical 4DCT respiratory trace. The real observed tumor motion (total displacement ≤ 8 mm) was evaluated first. Then, the motion range was artificially increased to 2 or 3 cm. Finally, T was increased to 60 s. While not realistic, making T comparable to the delivery time elucidates if the interplay effect can be observed. For a single fraction, the authors quantified the interplay effect as the maximum difference in the target dosimetric indices, most importantly the near-minimum dose (D99%), between all possible starting phases. For the three- and five-fractions, statistical simulations were performed when substantial interplay was found. For the motion amplitudes and periods obtained from the 4DCT, the interplay effect is negligible (<0.2%). It is also small (0.9% average, 2.2% maximum) when the target excursion increased to 2-3 cm. Only with large motion and increased period (60 s) was a significant interplay effect observed, with D99% ranging from 16% low to 17% high. The interplay effect was statistically significantly lower for the three- and five-fraction statistical simulations. Overall, the gradient effect dominates the clinical situation. A novel method was used to reconstruct the volumetric dose to a moving tumor during lung SBRT VMAT deliveries. With the studied planning and treatment technique for realistic motion periods, regardless of the amplitude, the interplay has nearly no impact on the near-minimum dose. The interplay effect was observed, for study purposes only, with the period comparable to the VMAT delivery time.
Oral 5-aminosalicylic acid for induction of remission in ulcerative colitis.
Feagan, Brian G; Macdonald, John K
2012-10-17
Oral 5-aminosalicylic acid (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs in doses of at least 2 g/day, were more effective than placebo but no more effective than SASP for inducing remission in ulcerative colitis. This updated review includes more recent studies and evaluates the efficacy and safety of 5-ASA preparations used for the treatment of mild to moderately active ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for induction of remission in active ulcerative colitis. A secondary objective of this systematic review was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A computer-assisted literature search for relevant studies (inception to January 20, 2012) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled clinical trials of parallel design, with a minimum treatment duration of four weeks. Studies of oral 5-ASA therapy for treatment of patients with active ulcerative colitis compared with placebo, SASP or other formulations of 5-ASA were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA (two or three times daily) and 5-ASA dose ranging studies were also considered for inclusion. The outcomes of interest were the failure to induce global/clinical remission, global/clinical improvement, endoscopic remission, endoscopic improvement, adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. SASP-controlled trials were subgrouped by 5-ASA/SASP mass ratios. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol, Claversal, Salofalk and Pentasa). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the relative risk (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention to treat basis. Forty-eight studies (7776 patients) were included. The majority of included studies were rated as low risk of bias. 5-ASA was significantly superior to placebo with regard to all measured outcome variables. Seventy-two per cent of 5-ASA patients failed to enter clinical remission compared to 85% of placebo patients (RR 0.86, 95% CI 0.81 to 0.91). A dose-response trend for 5-ASA was also observed. No statistically significant differences in efficacy were found between 5-ASA and SASP. Fifty-four per cent of 5-ASA patients failed to enter remission compared to 58% of SASP patients (RR 0.90, 95% CI 0.77 to 1.04). No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Forty-two per cent of once daily patients failed to enter clinical remission compared to 44% of conventionally dosed patients (RR 0.95, 95% CI 0.82 to 1.10). Eight per cent of patients dosed once daily failed to adhere to their medication regimen compared to 6% of conventionally dosed patients (RR 1.36, 95% CI 0.64 to 2.86). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Forty-eight per cent of patients in the 5-ASA group failed to enter remission compared to 50% of patients in the 5-ASA comparator group (RR 0.94, 95% CI 0.86 to 1.03). A pooled analysis of the ASCEND (I, II and III, n = 1459 patients) studies found no statistically significant difference in clinical improvement between Asacol 4.8 g/day and 2.4 g/day used for the treatment of moderately active ulcerative colitis. Thirty-seven per cent of patients in the 4.8 g/day group failed to improve clinically compared to 41% of patients in the 2.4 g/day group (RR 0.89; 95% CI 0.78 to 1.01). Subgroup analysis indicated that patients with moderate disease may benefit from the higher dose of 4.8 g/day. One study compared (n = 123 patients) Pentasa 4 g/day to 2.25 g/day in patients with moderate disease. Twenty-five per cent of patients in the 4 g/day group failed to improve clinically compared to 57% of patients in the 2.25 g/day group (RR 0.44; 95% CI 0.27 to 0.71). A pooled analysis of two studies comparing MMX mesalamine 4.8 g/day to 2.4 g/day found no statistically significant difference in efficacy (RR 1.03, 95% CI 0.82 to 1.29). 5-ASA was generally safe and common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache and worsening ulcerative colitis. There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulation and 5-ASA dose ranging (high dose versus low dose) studies. SASP was not as well tolerated as 5-ASA. Twenty-nine percent of SASP patients experienced an adverse event compared to 15% of 5-ASA patients (RR 0.48, 95% CI 0.37 to 0.63). 5-ASA was superior to placebo and no more effective than SASP. Considering their relative costs, a clinical advantage to using oral 5-ASA in place of SASP appears unlikely. 5-ASA dosed once daily appears to be as efficacious and safe as conventionally dosed 5-ASA. Adherence does not appear to be enhanced by once daily dosing in the clinical trial setting. It is unknown if once daily dosing of 5-ASA improves adherence in a community-based setting. There do not appear to be any differences in efficacy or safety among the various 5-ASA formulations. A daily dosage of 2.4 g appears to be a safe and effective induction therapy for patients with mild to moderately active ulcerative colitis. Patients with moderate disease may benefit from an initial dose of 4.8 g/day.
Oral 5-aminosalicylic acid for induction of remission in ulcerative colitis.
Wang, Yongjun; Parker, Claire E; Bhanji, Tania; Feagan, Brian G; MacDonald, John K
2016-04-21
Oral 5-aminosalicylic acid (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs in doses of at least 2 g/day, were more effective than placebo but no more effective than SASP for inducing remission in ulcerative colitis. This updated review includes more recent studies and evaluates the efficacy and safety of 5-ASA preparations used for the treatment of mild to moderately active ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for induction of remission in active ulcerative colitis. A secondary objective of this systematic review was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A computer-assisted literature search for relevant studies (inception to July 9, 2015) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled clinical trials of parallel design, with a minimum treatment duration of four weeks. Studies of oral 5-ASA therapy for treatment of patients with active ulcerative colitis compared with placebo, SASP or other formulations of 5-ASA were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA (two or three times daily) and 5-ASA dose ranging studies were also considered for inclusion. The outcomes of interest were the failure to induce global/clinical remission, global/clinical improvement, endoscopic remission, endoscopic improvement, adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. SASP-controlled trials were subgrouped by 5-ASA/SASP mass ratios. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol, Claversal, Salofalk and Pentasa). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the relative risk (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention-to-treat basis. Fifty-three studies (8548 patients) were included. The majority of included studies were rated as low risk of bias. 5-ASA was significantly superior to placebo with regard to all measured outcome variables. Seventy-one per cent of 5-ASA patients failed to enter clinical remission compared to 83% of placebo patients (RR 0.86, 95% CI 0.82 to 0.89). A dose-response trend for 5-ASA was also observed. No statistically significant differences in efficacy were found between 5-ASA and SASP. Fifty-four per cent of 5-ASA patients failed to enter remission compared to 58% of SASP patients (RR 0.90, 95% CI 0.77 to 1.04). No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Forty-five per cent of once daily patients failed to enter clinical remission compared to 48% of conventionally dosed patients (RR 0.94, 95% CI 0.83 to 1.07). Eight per cent of patients dosed once daily failed to adhere to their medication regimen compared to 6% of conventionally dosed patients (RR 1.36, 95% CI 0.64 to 2.86). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Fifty per cent of patients in the 5-ASA group failed to enter remission compared to 52% of patients in the 5-ASA comparator group (RR 0.94, 95% CI 0.86 to 1.02). A pooled analysis of 3 studies (n = 1459 patients) studies found no statistically significant difference in clinical improvement between Asacol 4.8 g/day and 2.4 g/day used for the treatment of moderately active ulcerative colitis. Thirty-seven per cent of patients in the 4.8 g/day group failed to improve clinically compared to 41% of patients in the 2.4 g/day group (RR 0.89; 95% CI 0.78 to 1.01). Subgroup analysis indicated that patients with moderate disease may benefit from the higher dose of 4.8 g/day. One study compared (n = 123 patients) Pentasa 4 g/day to 2.25 g/day in patients with moderate disease. Twenty-five per cent of patients in the 4 g/day group failed to improve clinically compared to 57% of patients in the 2.25 g/day group (RR 0.44; 95% CI 0.27 to 0.71). A pooled analysis of two studies comparing MMX mesalamine 4.8 g/day to 2.4 g/day found no statistically significant difference in efficacy (RR 1.03, 95% CI 0.82 to 1.29). There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulation and 5-ASA dose ranging (high dose versus low dose) studies. Common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache and worsening ulcerative colitis. SASP was not as well tolerated as 5-ASA. Twenty-nine percent of SASP patients experienced an adverse event compared to 15% of 5-ASA patients (RR 0.48, 95% CI 0.37 to 0.63). 5-ASA was superior to placebo and no more effective than SASP. Considering their relative costs, a clinical advantage to using oral 5-ASA in place of SASP appears unlikely. 5-ASA dosed once daily appears to be as efficacious and safe as conventionally dosed 5-ASA. Adherence does not appear to be enhanced by once daily dosing in the clinical trial setting. It is unknown if once daily dosing of 5-ASA improves adherence in a community-based setting. There do not appear to be any differences in efficacy or safety among the various 5-ASA formulations. A daily dosage of 2.4 g appears to be a safe and effective induction therapy for patients with mild to moderately active ulcerative colitis. Patients with moderate disease may benefit from an initial dose of 4.8 g/day.
Direct plan comparison of RapidArc and CyberKnife for spine stereotactic body radiation therapy
NASA Astrophysics Data System (ADS)
Choi, Young Eun; Kwak, Jungwon; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Cho, Byungchul
2015-07-01
We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan by using an analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both the CK and the RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended by the RTOG 0631 spine and 0915 lung SBRT protocols. The mean CI' SD values of the PTV were 1.11' 0.03 and 1.17' 0.10 for RA and CK ( p = 0.02), respectively. On average, the maximum dose delivered to the spinal cord in CK plans was approximately 11.6% higher than that in RA plans, and this difference was statistically significant ( p < 0.001). High-dose spillages were 0.86% and 2.26% for RA and CK ( p = 0.203), respectively. Intermediate-dose spillage characterized by D2cm was lower for RA than for CK; however, R50% was not statistically different. Even though both systems can create highly conformal volumetric dose distributions, the current study shows that RA demonstrates lower high- and intermediate-dose spillages than CK. Therefore, RA plans for spinal SBRT may be superior to CK plans.
James V. Neel and Yuri E. Dubrova: Cold War debates and the genetic effects of low-dose radiation.
Goldstein, Donna M; Stawkowski, Magdalena E
2015-01-01
This article traces disagreements about the genetic effects of low-dose radiation exposure as waged by James Neel (1915-2000), a central figure in radiation studies of Japanese populations after World War II, and Yuri Dubrova (1955-), who analyzed the 1986 Chernobyl nuclear power plant accident. In a 1996 article in Nature, Dubrova reported a statistically significant increase in the minisatellite (junk) DNA mutation rate in the children of parents who received a high dose of radiation from the Chernobyl accident, contradicting studies that found no significant inherited genetic effects among offspring of Japanese A-bomb survivors. Neel's subsequent defense of his large-scale longitudinal studies of the genetic effects of ionizing radiation consolidated current scientific understandings of low-dose ionizing radiation. The article seeks to explain how the Hiroshima/Nagasaki data remain hegemonic in radiation studies, contextualizing the debate with attention to the perceived inferiority of Soviet genetic science during the Cold War.
Cournoyer, Michael Edward; Costigan, Stephen Andrew; Schreiber, Stephen Bruce
2017-03-17
Plutonium emits both neutrons and photons and when it is stored or handled inside a glovebox, both photons and neutrons are significant external radiation hazards. Doses to the extremities are usually dominated by gamma radiation in typical plutonium glovebox operations. Excess external dose can generates stochastic effects consisting of cancer and benign tumors in some organs. Direct doses from radiation sources external to the body are measured by thermoluminescent dosimeters (TLDs) placed on the glovebox worker between the neck and waist. Wrist dosimeters are used to assess externally penetrating radiation including neutrons and provide an estimate of neutron radiation exposuremore » to the extremities. Both TLDs and wrist dosimeters are processed monthly for most glovebox workers. Here, worker collective extremity and external dose data have been analyzed to prevent and mitigate external radiation events through the use of Lean Manufacturing and Six Sigma business practices (LSS). Employing LSS, statistically significant variations (trends) are identified in worker collective extremity and external dose data. Finally, the research results presented in this paper are pivotal to the ultimate focus of this program, which is to minimize external radiation events.« less
Pupillometry as an indicator of L-DOPA dosages in Parkinson's disease patients.
Bartošová, O; Bonnet, C; Ulmanová, O; Šíma, M; Perlík, F; Růžička, E; Slanař, O
2018-04-01
Dopamine was shown to induce mydriasis by excitation of alpha-adrenergic receptors at the dilator pupillae muscle. Pupilla diameter may thus serve as an indirect measure of peripheral pharmacokinetics of L-DOPA and dopamine. The aim of this study is to evaluate the effect of L-DOPA dosage on pupillometric parameters in Parkinson's disease (PD) patients. Sixteen PD patients and 14 healthy control subjects (CS) were studied. The statistical analysis revealed significant differences between CS and PD patients for the mean maximum and minimum pupil diameters (p = 0.017, p = 0.028, respectively), with higher values found in PD. Moreover, a significant dose-response relationship was found between the maximum pupil diameter and both the morning L-DOPA dose (R 2 = 0.78) and the total daily L-DOPA dose (R 2 = 0.93). A sigmoid-shaped curve best describes the dose-response relationship, with a ceiling effect at about 400 mg L-DOPA daily dose. In conclusion, measuring pupillometric parameters represents a sensitive tool for non-invasive evaluation of the peripheral effect of L-DOPA, especially with daily doses below 400 mg L-DOPA.
Dose Trends of Aripiprazole from 2004 to 2014 in Psychiatric Inpatients in Korea.
Woo, Young Sup; Shim, In Hee; Lee, Sang-Yeol; Lee, Dae-Bo; Kim, Moon-Doo; Jung, Young-Eun; Lee, Jonghun; Won, Seunghee; Jon, Duk-In; Bahk, Won-Myong
2017-05-31
Although aripiprazole has been widely used to treat various psychiatric disorders, little is known about the adequate dosage for Asian patients in clinical practice. Hence, we evaluated the initial and maximum doses of aripiprazole from 2004 to 2014 to estimate the appropriate dosage for Korean psychiatric inpatients in clinical practice. In this retrospective study, we reviewed the medical records of patients who were hospitalized in five university hospitals in Korea from March 2004 to December 2014. The psychiatric diagnosis according to the text revision of the Diagnostic and Statistical Manual of Mental Disorders, 4th edition during index hospitalization and the initial and maximum doses of aripiprazole were evaluated. There were 74 patients in Wave 1 (2004-2006), 201 patients in Wave 2 (2007-2010), and 353 patients in Wave 3 (2011-2014). The initial doses of aripiprazole in all diagnostic groups were significantly lower in Wave 3 than in Wave 2. The maximum doses of aripiprazole in each diagnostic group were not significantly different among Waves 1, 2, and 3. The relatively low initial doses of aripiprazole documented in our study may reflect a strategy by clinicians to minimize the side effects associated with aripiprazole use, such as akathisia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael Edward; Costigan, Stephen Andrew; Schreiber, Stephen Bruce
Plutonium emits both neutrons and photons and when it is stored or handled inside a glovebox, both photons and neutrons are significant external radiation hazards. Doses to the extremities are usually dominated by gamma radiation in typical plutonium glovebox operations. Excess external dose can generates stochastic effects consisting of cancer and benign tumors in some organs. Direct doses from radiation sources external to the body are measured by thermoluminescent dosimeters (TLDs) placed on the glovebox worker between the neck and waist. Wrist dosimeters are used to assess externally penetrating radiation including neutrons and provide an estimate of neutron radiation exposuremore » to the extremities. Both TLDs and wrist dosimeters are processed monthly for most glovebox workers. Here, worker collective extremity and external dose data have been analyzed to prevent and mitigate external radiation events through the use of Lean Manufacturing and Six Sigma business practices (LSS). Employing LSS, statistically significant variations (trends) are identified in worker collective extremity and external dose data. Finally, the research results presented in this paper are pivotal to the ultimate focus of this program, which is to minimize external radiation events.« less
Lehmann-Che, Jacqueline; André, Fabrice; Desmedt, Christine; Mazouni, Chafika; Giacchetti, Sylvie; Turpin, Elisabeth; Espié, Marc; Plassa, Louis-François; Marty, Michel; Bertheau, Philippe; Sotiriou, Christos; Piccart, Martine; Symmans, W Fraser; Pusztai, Lajos; de Thé, Hugues
2010-01-01
The predictive value of p53 for the efficacy of front-line anthracycline-based chemotherapy regimens has been a matter of significant controversy. Anthracyclines are usually combined with widely different doses of alkylating agents, which may significantly modulate tumor response to these combinations. We analyzed three series of de novo stage II-III breast cancer patients treated front line with anthracycline-based regimens of various cyclophosphamide dose intensities: 65 patients with estrogen receptor (ER)(-) tumors treated with anthracyclines alone (Institut Jules Bordet, Brussels), 51 unselected breast cancer patients treated with intermediate doses of cyclophosphamide (MD Anderson Cancer Center, Houston, TX), and 128 others treated with a dose-dense anthracycline-cyclophosphamide combination (St. Louis, Paris). After chemotherapy and surgery, pathologic complete response (pCR) was evaluated. p53 status was determined by a yeast functional assay on the pretreatment tumor sample. In a multivariate analysis of the pooled results, a lack of ER expression and high-dose cyclophosphamide administration were associated with a higher likelihood of pCR. A sharp statistical interaction was detected between p53 status and cyclophosphamide dose intensity. Indeed, when restricting our analysis to patients with ER(-) tumors, we confirmed that a mutant p53 status was associated with anthracycline resistance, but found that p53 inactivation was required for response to the dose-intense alkylating regimen. The latter allowed very high levels of pCR in triple-negative tumors. Thus, our data strongly suggest that cyclophosphamide dose intensification in ER(-) p53-mutated breast cancer patients could significantly improve their response.
Tang, W H Wilson; Vagelos, Randall H; Yee, Yin-Gail; Fowler, Michael B
2004-11-01
The impact of angiotensin-converting enzyme (ACE) gene polymorphism on neurohormonal dose response to ACE inhibitor therapy is unclear. ACE Insertion (I) or Deletion (D) genotype was determined in 74 patients with chronic heart failure who were randomly assigned to receive either high-dose or low-dose enalapril over a period of 6 months. Monthly pre-enalapril and post-enalapril neurohormone levels (serum ACE activity (sACE), plasma angiotensin II (A-II), plasma renin activity (PRA), and serum aldosterone (ALDO) were compared between genotype subgroups and between patients who received high- or low-dose enalapril within each genotype subgroup. At baseline, predose/postdose sACE and postdose PRA were significantly higher in the DD genotype. At 6-month follow-up, postdose sACE was reduced in a dose-dependent fashion in all three genotypes (P < .05). However, predose and postdose ALDO and A-II levels did not differ between each genotype subgroup at baseline or by enalapril dose within each genotype subgroup. ALDO escape and A-II reactivation were not affected by ACE genotype or enalapril dosage. Predose sACE were consistently higher in the DD genotype when compared with ID or II subgroups. Despite a dose-dependent suppression of sACE, there were no observed statistically significant differences in ALDO and A-II suppression or escape with escalating doses of enalapril within each subgroup.
Safety of atomoxetine in combination with intravenous cocaine in cocaine-experienced participants.
Cantilena, Louis; Kahn, Roberta; Duncan, Connie C; Li, Shou-Hua; Anderson, Ann; Elkashef, Ahmed
2012-12-01
Atomoxetine has been considered as an agonist replacement therapy for cocaine. We investigated the safety of the interaction of atomoxetine with cocaine and also whether cognitive function was affected by atomoxetine during short-term administration. In a double-blind placebo-controlled inpatient study of 20 cocaine-dependent volunteers, participants received atomoxetine 80 mg daily followed by 100 mg daily for 5 days each. On the fourth and fifth day at each dose, cocaine (20 and 40 mg) was infused intravenously in sequential daily sessions. Preinfusion mean systolic pressures showed a small but statistically significant difference between placebo and both doses of atomoxetine. Preinfusion mean diastolic pressures were significant between placebo and atomoxetine 80 mg only. The diastolic pressure response to 40 mg cocaine was statistically significant only between the 80- and 100-mg atomoxetine doses. All electrocardiogram parameters were unchanged. Visual Analog Scale (VAS) scores for "bad effect" in the atomoxetine group were significantly higher at baseline, then declined, and for "likely to use" declined with atomoxetine treatment. On the Addiction Research Center Inventory, the atomoxetine group scored significantly lower on amphetamine, euphoria, and energy subscales (P < 0.0001). Other VAS descriptors, Brief Substance Craving Scale, Profile of Moods State, and Brief Psychiatric Rating Scale showed no differences. Atomoxetine did not affect cocaine pharmacokinetics. In tests of working memory, sustained attention, cognitive flexibility, and decision-making, atomoxetine improved performance on the visual n-back task. There were no differences in any pharmacokinetic parameters for cocaine with atomoxetine. Atomoxetine was tolerated safely by all participants. Certain cognitive improvements and a dampening effect on VAS scores after cocaine were observed, but should be weighed against small but significant differences in hemodynamic responses after atomoxetine.
Keskiner, I; Saygun, I; Bal, V; Serdar, M; Kantarci, A
2017-08-01
Recent studies have demonstrated the beneficial effects of omega-3 polyunsaturated fatty acids (PUFAs) on physiological processes and on a variety of chronic inflammatory diseases, including periodontal diseases. In this study, we evaluated the impact of omega-3 PUFAs in conjunction with scaling and root planing (SRP) on salivary markers in patients with chronic periodontitis. Thirty systemically healthy subjects with chronic periodontitis were enrolled and randomly allocated into two groups. The control group (n = 15) was treated with SRP + placebo whereas the test group was treated with SRP and dietary supplementation of low-dose omega-3 PUFAs (6.25 mg eicosapentaenoic acid and 19.19 mg docosahexaenoic acid). Clinical parameters were taken at baseline, 1, 3 and 6 mo following therapy. Saliva samples were obtained at the same time intervals and analyzed for tumor necrosis factor-α (TNF-α) and superoxide dismutase (SOD). Both groups showed significant changes in clinical parameters in response to treatment compared to baseline with no significant difference between groups. Salivary TNF-α levels showed a statistically significant decrease in the test group at 6 mo compared to the control group. Salivary SOD levels increased significantly at 3 and 6 mo in the test group and at 6 mo in placebo groups compared to baseline with no statistically significant differences between the groups. The results demonstrated that dietary supplementation with low-dose omega-3 PUFAs improves salivary TNF-α without any significant impact on clinical parameters in patients with chronic periodontitis, suggesting that the systemic benefits of dietary omega-3 PUFAs may not be translated to periodontal health. (ClinicalTrials.gov ID NCT02719587). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Safety of Atomoxetine in Combination with Intravenous Cocaine in Cocaine- Experienced Participants
Cantilena, Louis; Kahn, Roberta; Duncan, Connie C.; Li, Shou-Hua; Anderson, Ann; Elkashef, Ahmed
2012-01-01
Objectives Atomoxetine has been considered as an agonist replacement therapy for cocaine. We investigated the safety of the interaction of atomoxetine with cocaine, and also whether cognitive function was affected by atomoxetine during short-term administration. Methods In a double-blind placebo-controlled inpatient study of 20 cocaine-dependent volunteers, participants received atomoxetine 80 mg daily followed by 100 mg daily for 5 days each. On the fourth and fifth day at each dose, cocaine (20 mg and 40 mg) was infused intravenously in sequential daily sessions. Results Pre-infusion mean systolic pressures showed a small but statistically significant difference between placebo and both doses of atomoxetine. Pre-infusion mean diastolic pressures were significant between placebo and atomoxetine 80 mg only. The diastolic pressure response to 40 mg cocaine was statistically significant only between the 80 mg and 100 mg atomoxetine doses. All ECG parameters were unchanged. VAS scores for “bad effect” in the atomoxetine group were significantly higher at baseline, then declined, and for “likely to use” declined with atomoxetine treatment. On the ARCI the atomoxetine group scored significantly lower on amphetamine, euphoria and energy subscales (p<0.0001). Other VAS descriptors, BSCS, POMS, and BPRS showed no differences. Atomoxetine did not affect cocaine pharmacokinetics. In tests of working memory, sustained attention, cognitive flexibility, and decision-making, atomoxetine improved performance on the visual n-back task. There were no differences in any pharmacokinetic parameters for cocaine with atomoxetine. Conclusions Atomoxetine was tolerated safely by all participants. Certain cognitive improvements and a dampening effect on VAS scores after cocaine were observed, but should be weighed against small but significant differences in hemodynamic responses after atomoxetine. PMID:22987022
Fullmer, Spencer; Drum, Melissa; Reader, Al; Nusstein, John; Beck, Mike
2014-01-01
The purpose of this prospective, randomized, double-blind, placebo-controlled study was to determine the effect of the administration of the combination acetaminophen/hydrocodone on the anesthetic success of mandibular posterior teeth in patients experiencing symptomatic irreversible pulpitis. One hundred emergency patients in moderate to severe pain diagnosed with symptomatic irreversible pulpitis of a mandibular posterior tooth randomly received, in a double-blind manner, identical capsules of either a combination dose of 1000 mg acetaminophen/10 mg hydrocodone or placebo 60 minutes before the administration of a conventional inferior alveolar nerve (IAN) block. Endodontic access was begun 15 minutes after completion of the block, and all patients used for data analysis had profound lip numbness. Success was defined as no or mild pain (visual analog scale recordings) on pulpal access or instrumentation. The success rate for the IAN block was 32% for the combination dose of 1000 mg acetaminophen/10 hydrocodone and 28% for the placebo dose, with no statistically significant difference between the 2 groups (P = .662). A combination dose of 1000 mg acetaminophen/10 mg hydrocodone given 60 minutes before the administration of the IAN block did not result in a statistically significant increase in anesthetic success for mandibular posterior teeth in patients experiencing symptomatic irreversible pulpitis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Switching to instant black coffee modulates sodium selenite-induced cataract in rats.
El Okda, E A; Mohamed, M M; Shaheed, E B; Abdel-Moemin, A R
2016-01-01
The influence of daily consumption of some common beverages on the development of cataract in rats was investigated. Total phenol content was determined in the beverages and an oral standardized dose of total phenols from each beverage was given to the treated rats. Weaned male albino rats were used and divided into five groups (n=7). Rats were fed Ain 93G and administered the standardized dose of instant coffee, black tea and hibiscus beverages for 30 days. On day 14 all rats were injected with a single dose of sodium selenite (Na2SeO3) 15 µmol/kg bodyweight, except the control groups NC (negative control, did not receive Na2SeO3) and PC (positive control, was already injected on day 1 of the study). The rats were continued on Ain 93G and the standardized dose for another 16 days. Positive control rats were used. Total phenols were 210, 40, and 44 mg/g dry weight gallic acid equivalent in black coffee, black tea, and hibiscus, respectively. Decreased levels (statistically significant P<0.05) of malondialdehyde, total nitric oxide, Ca-ATPase, tumor necrosis factor-α, interleukin-1β, superoxide dismutase, and conversely, increased levels (statistically significant P<0.05) of total protein, reduced glutathione, catalase were found in the lenses of the coffee group compared to PC. There are co-phenol substances in the instant black coffee that promoted coffee to be the most effective beverage.
Switching to instant black coffee modulates sodium selenite-induced cataract in rats
El Okda, E. A.; Mohamed, M. M.; Shaheed, E. B.; Abdel-Moemin, A. R.
2016-01-01
The influence of daily consumption of some common beverages on the development of cataract in rats was investigated. Total phenol content was determined in the beverages and an oral standardized dose of total phenols from each beverage was given to the treated rats. Weaned male albino rats were used and divided into five groups (n=7). Rats were fed Ain 93G and administered the standardized dose of instant coffee, black tea and hibiscus beverages for 30 days. On day 14 all rats were injected with a single dose of sodium selenite (Na2SeO3) 15 µmol/kg bodyweight, except the control groups NC (negative control, did not receive Na2SeO3) and PC (positive control, was already injected on day 1 of the study). The rats were continued on Ain 93G and the standardized dose for another 16 days. Positive control rats were used. Total phenols were 210, 40, and 44 mg/g dry weight gallic acid equivalent in black coffee, black tea, and hibiscus, respectively. Decreased levels (statistically significant P<0.05) of malondialdehyde, total nitric oxide, Ca-ATPase, tumor necrosis factor-α, interleukin-1β, superoxide dismutase, and conversely, increased levels (statistically significant P<0.05) of total protein, reduced glutathione, catalase were found in the lenses of the coffee group compared to PC. There are co-phenol substances in the instant black coffee that promoted coffee to be the most effective beverage. PMID:27158251
Surana, Sikander; Kumar, Neeru; Vasudeva, Amita; Shaikh, Gulvahid; Jhaveri, Kenar D; Shah, Hitesh; Malieckal, Deepa; Fogel, Joshua; Sidhu, Gurwinder; Rubinstein, Sofia
2017-01-17
Drug dosing errors result in adverse patient outcomes and are more common in patients with chronic kidney disease (CKD). As internists treat the majority of patients with CKD, we study if Internal Medicine house-staff have awareness and knowledge about the correct dosage of commonly used medications for those with CKD. A cross-sectional survey was performed and included 341 participants. The outcomes were the awareness of whether a medication needs dose adjustment in patients with CKD and whether there was knowledge for the level of glomerular filtration rate (GFR) a medication needs to be adjusted. The overall pattern for all post-graduate year (PGY) groups in all medication classes was a lack of awareness and knowledge. For awareness, there were statistically significant increased mean differences for PGY2 and PGY3 as compared to PGY1 for allergy, endocrine, gastrointestinal, and rheumatologic medication classes but not for analgesic, cardiovascular, and neuropsychotropic medication classes. For knowledge, there were statistically significant increased mean differences for PGY2 and PGY3 as compared to PGY1 for allergy, cardiovascular, endocrine, and gastrointestinal, medication classes but not for analgesic, neuropsychotropic, and rheumatologic medication classes. Internal Medicine house-staff across all levels of training demonstrated poor awareness and knowledge for many medication classes in CKD patients. Internal Medicine house-staff should receive more nephrology exposure and formal didactic educational training during residency to better manage complex treatment regimens and prevent medication dosing errors.
Rassias, Athos J; Guyre, Paul M; Yeager, Mark P
2011-12-01
We evaluated the differential impact of stress-associated vs high pharmacologic concentrations of hydrocortisone pretreatment on heart rate variability (HRV) during a subsequent systemic inflammatory stimulus. Healthy volunteers were randomized to receive placebo (Control) and hydrocortisone at 1.5 μg/kg per minute (STRESS) or at 3.0 μg/kg per minute (PHARM) as a 6-hour infusion. The STRESS dose was chosen to replicate the condition of physiologic adrenal cortical output during acute systemic stress. The PHARM dose was chosen to induce a supraphysiologic concentration of cortisol. The next day, all subjects received 2 ng/kg Escherichia coli endotoxin (lipopolysaccharide). Heart rate variability was analyzed with the statistic approximate entropy (ApEn). A lower ApEn correlates with decreased HRV. At the 3-hour nadir, the decrease in ApEn in the STRESS group was significantly less compared to placebo (P < .03), whereas ApEn in the PHARM group was not statistically different. We also found that the maximal decrease in ApEn preceded maximal increase in heart rate in all groups. The decrease in R-R interval was maximal at 4 hours, whereas the ApEn nadir was 1 hour earlier at 3 hours. Pretreatment with a stress dose of hydrocortisone but not a higher pharmacologic dose maintained a significantly higher ApEn after endotoxin exposure when compared to a placebo. In addition, decreases in ApEn preceded increases in heart rate. Copyright © 2011 Elsevier Inc. All rights reserved.
Cosmetic wastewater treatment by the ZVI/H2O2 process.
Bogacki, Jan; Marcinowski, Piotr; Zapałowska, Ewa; Maksymiec, Justyna; Naumczyk, Jeremi
2017-10-01
The ZVI/H 2 O 2 process was applied for cosmetic wastewater treatment. Two commercial zero-valent iron (ZVI) types with different granulations were chosen: Hepure Ferrox PRB and Hepure Ferrox Target. In addition, the pH and stirring method influence on ZVI/H 2 O 2 process efficiency was studied. During the ZVI and ZVI/H 2 O 2 processes, linear Fe ions concentration increase was observed. The addition of H 2 O 2 significantly accelerated the iron dissolution process. The highest COD removal was obtained using finer ZVI (Hepure Ferrox Target) for doses of reagents ZVI/H 2 O 2 1500/1600 mg/L, in a H 2 O 2 /COD weight ratio 2:1, at pH 3.0 with stirring on a magnetic stirrer. After 120 min of the process, 84.0% COD removal (from 796 to 127 mg/L) was achieved. It was found that the efficiency of the process depends, as in the case of the Fenton process, on the ratio of the reagents (ZVI/H 2 O 2 ) and their dose in relation to the COD (H 2 O 2 /COD) but does not depend on the dose of the iron itself. Statistical analysis confirms that COD removal efficiency depends primarily on H 2 O 2 /COD ratio and ZVI granulation, but ZVI dose influence is not statistically significant. The head space, solid-phase microextraction, gas chromatography, mass spectrometry results confirm high efficiency of the ZVI/H 2 O 2 process.
Evaluation of the genotoxicity of alpha-amanitin in mice bone marrow cells.
Marciniak, B; Łopaczyńska, D; Ferenc, T
2017-10-01
Alpha-amanitin is a known cytotoxic substance found in some mushroom species including Amanita phalloides. Its main mechanism of action is to block the transcription, which can lead to cell death. Lack of reports on the genotoxicity of this toxin was an inspiration for undertaking this experiment. Genotoxic effect of α-amanitin on balb/c mice bone marrow cells was tested using: comet assay and chromosomal aberration test. The tested substance was given once by intraperitoneal administration to animals at doses: 0.1 mg/kg, 0.15 mg/kg and 0.25 mg/kg (LD 50 ) body weight with 48 h exposure. The comet assay demonstrated a statistically significant increase in DNA damage for all the investigated α-amanitin doses compared to the negative control (p < 0.0001). The exposure to 0.15 and 0.25 mg/kg doses of α-amanitin also generated a statistically significant increase in the frequency of chromosomal aberrations in bone marrow cells of mice compared to the negative control (p < 0.05). The genotoxic effect induced by α-amanitin in mammalian cells can result in genome instability and its functional consequences. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, X; Sun, T; Yin, Y
Purpose: To study the dosimetric impact of intensity-modulated radiotherapy (IMRT), hybrid intensity-modulated radiotherapy (h-IMRT) and volumetric modulated arc therapy(VMAT) for whole-brain radiotherapy (WBRT) with simultaneous integrated boost in patients with multiple brain metastases. Methods: Ten patients with multiple brain metastases were included in this analysis. The prescribed dose was 45 Gy to the whole brain (PTVWBRT) and 55 Gy to individual brain metastases (PTVboost) delivered simultaneously in 25 fractions. Three treatment techniques were designed: the 7 equal spaced fields IMRT plan, hybrid IMRT plan and VMAT with two 358°arcs. In hybrid IMRT plan, two fields(90°and 270°) were planned to themore » whole brain. This was used as a base dose plan. Then 5 fields IMRT plan was optimized based on the two fields plan. The dose distribution in the target, the dose to the organs at risk and total MU in three techniques were compared. Results: For the target dose, conformity and homogeneity in PTV, no statistically differences were observed in the three techniques. For the maximum dose in bilateral lens and the mean dose in bilateral eyes, IMRT and h-IMRT plans showed the highest and lowest value respectively. No statistically significant differences were observed in the dose of optic nerve and brainstem. For the monitor units, IMRT and VMAT plans showed the highest and lowest value respectively. Conclusion: For WBRT with simultaneous integrated boost in patients with multiple brain metastases, hybrid IMRT could reduce the doses to lens and eyes. It is feasible for patients with brain metastases.« less
Marchetti, C; De Felice, F; Di Pinto, A; D'Oria, O; Aleksa, N; Musella, A; Palaia, I; Muzii, L; Tombolini, V; Benedetti Panici, P
2018-05-01
The use of dose-dense weekly chemotherapy in the management of advanced ovarian cancer (OC) remains controversial. The aim of this meta-analysis was to evaluate the efficacy of dose-dense regimen to improve clinical outcomes in OC patients with the inclusion of new trials. For this updated meta-analysis, PubMed Medline and Scopus databases and meeting proceedings were searched for eligible studies with the limitation of randomized controlled trials, comparing dose-dense chemotherapy versus standard treatment. Trials were grouped in two types of dose-dense chemotherapy: weekly dose-dense (both paclitaxel and carboplatin weekly administration) and semi-weekly dose-dense (weekly paclitaxel and three weekly carboplatin administration). Data were extracted independently and were analyzed using RevMan statistical software version 5.3 (http://www.cochrane.org). Primary end-point was progression-free survival (PFS). Four randomized controlled trials comprising 3698 patients were identified as eligible. Dose-dense chemotherapy had not a significant benefit on PFS (HR 0.92, 95% CI 0.81-1.04, p = 0.20). When the analysis was restricted to both weekly and semi-weekly dose-dense data, a no significant interaction between dose-dense and standard regimen was confirmed (HR 1.01, 95% CI 0.93-1.10 and HR 0.82, 95% CI 0.63-1.08, respectively). In the absence of PFS superiority of dose-dense schedule, three weekly schedule should remain the standard of care for advanced OC. Copyright © 2018 Elsevier B.V. All rights reserved.
Topical nasal decongestant oxymetazoline (0.05%) provides relief of nasal symptoms for 12 hours.
Druce, H M; Ramsey, D L; Karnati, S; Carr, A N
2018-05-22
Nasal congestion, often referred to as stuffy nose or blocked nose is one of the most prevalent and bothersome symptoms of an upper respiratory tract infection. Oxymetazoline, a widely used intranasal decongestant, offers fast symptom relief, but little is known about the duration of effect. The results of 2 randomized, double-blind, vehicle-controlled, single-dose, parallel, clinical studies (Study 1, n=67; Study 2, n=61) in which the efficacy of an oxymetazoline (0.05% Oxy) nasal spray in patients with acute coryzal rhinitis was assessed over a 12-hour time-period. Data were collected on both subjective relief of nasal congestion (6-point nasal congestion scale) and objective measures of nasal patency (anterior rhinomanometry) in both studies. A pooled study analysis showed statistically significant changes from baseline in subjective nasal congestion for 0.05% oxymetazoline and vehicle at each hourly time-point from Hour 1 through Hour 12 (marginally significant at Hour 11). An objective measure of nasal flow was statistically significant at each time-point up to 12 hours. Adverse events on either treatment were infrequent. The number of subjects who achieved an improvement in subjective nasal congestion scores of at least 1.0 was significantly higher in the Oxy group vs. vehicle at all hourly time-points on a 6-point nasal congestion scale. This study shows for the first time, that oxymetazoline provides both statistically significant and clinically meaningful relief of nasal congestion and improves nasal airflow for up to 12 hours following a single dose.
Toh, Zheng Quan; Russell, Fiona M; Reyburn, Rita; Fong, James; Tuivaga, Evelyn; Ratu, Tupou; Nguyen, Cattram D; Devi, Rachel; Kama, Mike; Matanitobua, Silivia; Tabrizi, Sepehr N; Garland, Suzanne M; Sinha, Rohit; Frazer, Ian; Tikoduadua, Lisi; Kado, Joseph; Rafai, Eric; Mulholland, Edward K; Licciardi, Paul V
2017-04-01
The duration of antibody response following reduced human papillomavirus (HPV) vaccine doses has not been determined. We compared the antibody responses in girls previously vaccinated with zero, 1, 2, or 3 doses of quadrivalent HPV vaccine (4vHPV; Gardasil, Merck) 6 years previously. A prospective cohort study was undertaken in 200 Fijian girls 15-19 years of age. Approximately equal numbers of girls from 2 main ethnic groups (Fijians of Indian descent [FID] and Indigenous Fijians [iTaukei]) in Fiji were recruited for each dosage groups. Blood was drawn before and 28 days following a single dose of bivalent HPV vaccine (2vHPV; Cervarix, GlaxoSmithKline). We measured neutralizing antibodies (NAb) against HPV-6, -11, -16, and -18 using the pseudovirion-based neutralization assay. After 6 years (before a dose of 2vHPV was given), the geometric mean NAb titers for all 4 HPV types were not statistically different between 2-dose (2D) and 3-dose (3D) recipients: HPV-6 (3D: 2216 [95% confidence interval {CI},1695-2896]; 2D: 1476 [95% CI, 1019-2137]; P = .07), HPV-11 (3D: 4431 [95% CI, 3396-5783]; 2D: 2951 [95% CI, 1984-4390]; P = .09), HPV-16 (3D: 3373 [95% CI, 2511-4530]; 2D: 3275 [95% CI, 2452-4373]; P = .89); HPV-18 (3D: 628 [95% CI: 445-888]; 2D: 606 [95% CI, 462-862]; P = .89), and were higher in FID than iTaukei girls. Although 1-dose recipients had significantly lower NAb titers than 2-/3-dose recipients, their NAb titers were 5- to 30-fold higher than unvaccinated girls. Post-2vHPV NAb titers against HPV-16 and -18 were not statistically different between girls who received 1, 2, or 3 doses of 4vHPV previously. Two doses of 4vHPV provide similar NAb titers as 3 doses for 6 years, although the clinical significance is unknown. A single dose of 4vHPV elicits antibodies that persisted for at least 6 years, and induced immune memory, suggesting possible protection against HPV vaccine types after a single dose of 4vHPV. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palma, Giuseppe; Monti, Serena; D'Avino, Vittoria
Purpose: To apply a voxel-based (VB) approach aimed at exploring local dose differences associated with late radiation-induced lung damage (RILD). Methods and Materials: An interinstitutional database of 98 patients who were Hodgkin lymphoma (HL) survivors treated with postchemotherapy supradiaphragmatic radiation therapy was analyzed in the study. Eighteen patients experienced late RILD, classified according to the Radiation Therapy Oncology Group scoring system. Each patient's computed tomographic (CT) scan was normalized to a single reference case anatomy (common coordinate system, CCS) through a log-diffeomorphic approach. The obtained deformation fields were used to map the dose of each patient into the CCS. Themore » coregistration robustness and the dose mapping accuracy were evaluated by geometric and dose scores. Two different statistical mapping schemes for nonparametric multiple permutation inference on dose maps were applied, and the corresponding P<.05 significance lung subregions were generated. A receiver operating characteristic (ROC)-based test was performed on the mean dose extracted from each subregion. Results: The coregistration process resulted in a geometrically robust and accurate dose warping. A significantly higher dose was consistently delivered to RILD patients in voxel clusters near the peripheral medial-basal portion of the lungs. The area under the ROC curves (AUC) from the mean dose of the voxel clusters was higher than the corresponding AUC derived from the total lung mean dose. Conclusions: We implemented a framework including a robust registration process and a VB approach accounting for the multiple comparison problem in dose-response modeling, and applied it to a cohort of HL survivors to explore a local dose–RILD relationship in the lungs. Patients with RILD received a significantly greater dose in parenchymal regions where low doses (∼6 Gy) were delivered. Interestingly, the relation between differences in the high-dose range and RILD seems to lack a clear spatial signature.« less
Herlitz, Georg N; Arlow, Renee L; Cheung, Nora H; Coyle, Susette M; Griffel, Benjamin; Macor, Marie A; Lowry, Stephen F; Calvano, Steve E; Gale, Stephen C
2015-02-01
Human injury or infection induces systemic inflammation with characteristic neuroendocrine responses. Fluctuations in autonomic function during inflammation are reflected by beat-to-beat variation in heart rate, termed heart rate variability (HRV). In the present study, we determine threshold doses of endotoxin needed to induce observable changes in markers of systemic inflammation, investigate whether metrics of HRV exhibit a differing threshold dose from other inflammatory markers, and investigate the size of data sets required for meaningful use of multiscale entropy (MSE) analysis of HRV. Healthy human volunteers (n = 25) were randomized to receive placebo (normal saline) or endotoxin/lipopolysaccharide (LPS): 0.1, 0.25, 0.5, 1.0, or 2.0 ng/kg administered intravenously. Vital signs were recorded every 30 min for 6 h and then at 9, 12, and 24 h after LPS. Blood samples were drawn at specific time points for cytokine measurements. Heart rate variability analysis was performed using electrocardiogram epochs of 5 min. Multiscale entropy for HRV was calculated for all dose groups to scale factor 40. The lowest significant threshold dose was noted in core temperature at 0.25 ng/kg. Endogenous tumor necrosis factor α and interleukin 6 were significantly responsive at the next dosage level (0.5 ng/kg) along with elevations in circulating leukocytes and heart rate. Responses were exaggerated at higher doses (1 and 2 ng/kg). Time domain and frequency domain HRV metrics similarly suggested a threshold dose, differing from placebo at 1.0 and 2.0 ng/kg, below which no clear pattern in response was evident. By applying repeated-measures analysis of variance across scale factors, a significant decrease in MSE was seen at 1.0 and 2.0 ng/kg by 2 h after exposure to LPS. Although not statistically significant below 1.0 ng/kg, MSE unexpectedly decreased across all groups in an orderly dose-response pattern not seen in the other outcomes. By using repeated-measures analysis of variance across scale factors, MSE can detect autonomic change after LPS challenge in a group of 25 subjects using electrocardiogram epochs of only 5 min and entropy analysis to scale factor of only 40, potentially facilitating MSE's wider use as a research tool or bedside monitor. Traditional markers of inflammation generally exhibit threshold dose behavior. In contrast, MSE's apparent continuous dose-response pattern, although not statistically verifiable in this study, suggests a potential subclinical harbinger of infectious or other insult. The possible derangement of autonomic complexity prior to or independent of the cytokine surge cannot be ruled out. Future investigation should focus on confirmation of overt inflammation following observed decreases in MSE in a clinical setting.
Herlitz, Georg N.; Sanders, Renee L.; Cheung, Nora H.; Coyle, Susette M.; Griffel, Benjamin; Macor, Marie A.; Lowry, Stephen F.; Calvano, Steve E.; Gale, Stephen C.
2014-01-01
Introduction Human injury or infection induces systemic inflammation with characteristic neuro-endocrine responses. Fluctuations in autonomic function during inflammation are reflected by beat-to-beat variation in heart rate, termed heart rate variability (HRV). In the present study, we determine threshold doses of endotoxin needed to induce observable changes in markers of systemic inflammation, we investigate whether metrics of HRV exhibit a differing threshold dose from other inflammatory markers, and we investigate the size of data sets required for meaningful use of multi-scale entropy (MSE) analysis of HRV. Methods Healthy human volunteers (n=25) were randomized to receive placebo (normal saline) or endotoxin/lipopolysaccharide (LPS): 0.1, 0.25, 0.5, 1.0, or 2.0 ng/kg administered intravenously. Vital signs were recorded every 30 minutes for 6 hours and then at 9, 12, and 24 hours after LPS. Blood samples were drawn at specific time points for cytokine measurements. HRV analysis was performed using EKG epochs of 5 minutes. MSE for HRV was calculated for all dose groups to scale factor 40. Results The lowest significant threshold dose was noted in core temperature at 0.25ng/kg. Endogenous TNF-α and IL-6 were significantly responsive at the next dosage level (0.5ng/kg) along with elevations in circulating leukocytes and heart rate. Responses were exaggerated at higher doses (1 and 2 ng/kg). Time domain and frequency domain HRV metrics similarly suggested a threshold dose, differing from placebo at 1.0 and 2.0 ng/kg, below which no clear pattern in response was evident. By applying repeated-measures ANOVA across scale factors, a significant decrease in MSE was seen at 1.0 and 2.0 ng/kg by 2 hours post exposure to LPS. While not statistically significant below 1.0 ng/kg, MSE unexpectedly decreased across all groups in an orderly dose-response pattern not seen in the other outcomes. Conclusions By usingrANOVA across scale factors, MSE can detect autonomic change after LPS challenge in a group of 25 subjects using EKG epochs of only 5 minutes and entropy analysis to scale factor of only 40, potentially facilitating MSE’s wider use as a research tool or bedside monitor. Traditional markers of inflammation generally exhibit threshold dose behavior. In contrast, MSE’s apparent continuous dose-response pattern, while not statistically verifiable in this study, suggests a potential subclinical harbinger of infectious or other insult. The possible derangement of autonomic complexity prior to or independent of the cytokine surge cannot be ruled out. Future investigation should focus on confirmation of overt inflammation following observed decreases in MSE in a clinical setting. PMID:25526373
Analgesic effects of β-phenylethylamine and various methylated derivatives in mice.
Mosnaim, Aron D; Hudzik, Thomas; Wolf, Marion E
2014-09-01
Administration of β-phenylethylamine (PEA), the simplest endogenous neuroamine, and various methylated PEA derivatives including α-methyl PEA (amphetamine, AMP) elicits analgesia in mice. Five or 20 min after intraperitoneal PEA injection of as little as 6 mg/kg resulted in an increased latency response time (from 2.4 ± 0.4 to 8.5 ± 2.3 or 7.0 ± 3.0 s, respectively) to the thermal stimulus (hot-plate test), which reached statistical significance at the 15 mg/kg (20 min; 13.1 ± 0.4 s) or 25 mg/kg dose (5 min; 15.3 ± 4.1 s). This PEA effect, was dose-dependent (albeit non-linear: 6, 12, 15, 25, 50 and 100 mg/kg), reached the cut-off time of 45 s at the upper PEA dose (5 min), and it was consistently enhanced by pretreatment with the monoamine oxidase inhibitor pargyline (P). Methylated PEA derivatives (15 and 100 mg/kg dose) produced various degrees of analgesia (in decreasing order p-Me PEA > PEA > N,N-diMe PEA > N-Me PEA) which, likewise to PEA itself, were consistently increased by P and declined over time (mice tested 5, 20 and 60 min after amine injection); small but statistically significant o- and β-Me PEA antinociceptive effects (5 min) were observed only at the higher dose (in the presence of P for β-Me PEA). A small analgesic effect was observed after the administration of AMP (5 or 10 mg/kg) which failed, even after P, to reach statistically significance. Independent of the amine and concentration tested, individual compound's antinociceptive properties were reliably increased by P (exception of AMP), decreased by reserpine (R) or haloperidol (H), and remained essentially unchanged after naloxone (N) administration suggesting the involvement of catecholamines, but not opioid peptides, in their observed analgesic effects. Injection of P + N produced results similar to those seen after P alone. Under the experimental conditions described neither P, R, H or N had any effects by themselves. These findings suggest additional understanding of the mechanism of action responsible for the analgesic effects of these amines would be of interest, leading further to controlled studies on their alleged usefulness as weight reducing agents and sport performance enhancers.
Yakoot, Mostafa; Salem, Amel; Yousef, Sameh; Helmy, Sherine
2014-01-01
Renal colic is typically characterized by the sudden onset of severe pain radiating from the flank to the groin and its acute management in emergency departments essentially aims at rapid pain relief. Spasmofen(®) is a brand of Amriya Pharmaceutical Industries in the form of rectal suppositories containing ketoprofen 100 mg and hyoscine butylbromide 10 mg. This combination is intended for the rapid relief of severe colicky pain in the renal system, hepatobiliary system, or gastrointestinal tract. This trial aims to compare a single-dose of Spasmofen rectal suppository to a single intravenous (IV) ketorolac tromethamine 30 mg/2 mL dose in patients with acute renal colic. A total of 80 eligible consecutive patients presenting to the emergency departments of two medical centers with acute renal colic were included in the study. Eligible patients who signed the informed consent were randomly assigned into two treatment groups: an experimental group (Spasmofen group) who received one Spasmofen rectal suppository plus an IV injection of 2 mL of normal saline solution; and a control group (ketorolac group) who received one ketorolac 30 mg/2 mL ampoule IV plus one placebo suppository. Treatment success, defined as a change in the verbal rating score from severe or moderate pain to none or mild at 60 minutes after the dose, was compared between groups using the chi-square/Fisher's exact test. Percentage reductions in visual pain analog scale (VPAS) scores at 15 and 60 minutes after the dose were compared between groups using the Z-test for proportions. Successful treatment at 60 minutes occurred in 35 of 40 (87.5%) of Spasmofen-treated patients and in 33 of 40 (82.5%) of ketorolac-treated patients. The difference was not statistically significant by Fisher's exact test (P=0.755). The mean percentage reduction of VPAS after 15 minutes was 61.82% in the Spasmofen-treated group and 64.76% in the ketorolac-treated group. The difference was also not statistically significant by the Z-test for proportions (P=0.795). Sixty minutes after being treated, Spasmofen was associated with a statistically significant greater reduction in VPAS (mean% reduction =92.36%) than ketorolac (75.06%; P=0.0466). Single-dose Spasmofen rectal suppository might be a safe and effective first-aid treatment for the emergency department relief of acute renal colic.
Latifi, Kujtim; Oliver, Jasmine; Baker, Ryan; Dilling, Thomas J; Stevens, Craig W; Kim, Jongphil; Yue, Binglin; Demarco, Marylou; Zhang, Geoffrey G; Moros, Eduardo G; Feygelman, Vladimir
2014-04-01
Pencil beam (PB) and collapsed cone convolution (CCC) dose calculation algorithms differ significantly when used in the thorax. However, such differences have seldom been previously directly correlated with outcomes of lung stereotactic ablative body radiation (SABR). Data for 201 non-small cell lung cancer patients treated with SABR were analyzed retrospectively. All patients were treated with 50 Gy in 5 fractions of 10 Gy each. The radiation prescription mandated that 95% of the planning target volume (PTV) receive the prescribed dose. One hundred sixteen patients were planned with BrainLab treatment planning software (TPS) with the PB algorithm and treated on a Novalis unit. The other 85 were planned on the Pinnacle TPS with the CCC algorithm and treated on a Varian linac. Treatment planning objectives were numerically identical for both groups. The median follow-up times were 24 and 17 months for the PB and CCC groups, respectively. The primary endpoint was local/marginal control of the irradiated lesion. Gray's competing risk method was used to determine the statistical differences in local/marginal control rates between the PB and CCC groups. Twenty-five patients planned with PB and 4 patients planned with the CCC algorithms to the same nominal doses experienced local recurrence. There was a statistically significant difference in recurrence rates between the PB and CCC groups (hazard ratio 3.4 [95% confidence interval: 1.18-9.83], Gray's test P=.019). The differences (Δ) between the 2 algorithms for target coverage were as follows: ΔD99GITV = 7.4 Gy, ΔD99PTV = 10.4 Gy, ΔV90GITV = 13.7%, ΔV90PTV = 37.6%, ΔD95PTV = 9.8 Gy, and ΔDISO = 3.4 Gy. GITV = gross internal tumor volume. Local control in patients receiving who were planned to the same nominal dose with PB and CCC algorithms were statistically significantly different. Possible alternative explanations are described in the report, although they are not thought likely to explain the difference. We conclude that the difference is due to relative dosimetric underdosing of tumors with the PB algorithm. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashenafi, M; McDonald, D; Peng, J
Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinicalmore » target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription, while maintaining similar target coverage.« less
Memory effects of Aronia melanocarpa fruit juice in a passive avoidance test in rats.
Valcheva-Kuzmanova, Stefka V; Eftimov, Miroslav Tz; Tashev, Roman E; Belcheva, Iren P; Belcheva, Stiliana P
2014-01-01
To study the effect of Aronia melanocarpa fruit juice on memory in male Wistar rats. The juice was administered orally for 7, 14, 21 and 30 days at doses of 2.5 ml/kg, 5 ml/kg and 10 ml/kg. Memory was assessed in the one-way passive avoidance task (step through) which consisted of one training session and two retention tests (3 hours and 24 hours after training). The variables measured were the latency time to step into the dark compartment of the apparatus and the learning criterion (remaining in the illuminated compartment for at least 180 sec). Oral administration of Aronia melanocarpa fruit juice for 7 and 14 days resulted in a dose-dependent tendency to increase the latency time and the learning criterion compared to saline-treated controls but the effect failed to reach statistical significance. After 21 days of treatment, the juice dose-dependently prolonged the latency time at the retention tests, the effect being significant at doses of 5 ml/kg and 10 ml/kg. Applied for 30 days, the juice in all the tested doses increased significantly the latency time at the retention tests and the dose of 10 ml/kg significantly increased the percentage of rats reaching the learning criterion. These findings suggest that Aronia melanocarpa fruit juice could improve memory in rats. The effect is probably due to the polyphenolic ingredients of the juice which have been shown to be involved in learning and memory processes.
Camacho-Alonso, Fabio; López-Jornet, Pía; Vicente-Hernández, Ascensión
2013-05-01
The aim of this study was to compare the effects in terms of resistance to fracture of the mandibular condyle and femoral head following different doses of zoledronic acid in an animal model. A total of 80 adult male Sprague-Dawley rats were included in a prospective randomized study. The animals were randomly divided into four groups of 20 rats each. Group 1 (control) received sterile saline solution, while groups 2, 3 and 4 received a accumulated dose of 0.2 mg, 0.4 mg and 0.6 mg of zoledronic acid, respectively. The animals were sacrificed 28 days after the last dose, and the right hemimandible and the right femur were removed. The fracture strength was measured (in Newtons) with a universal test machine using a 1 kN load connected to a metal rod with one end angled at 30 degrees. The cross-head speed was 1 mm/min. Later, the specimens were observed under a scanning electron microscope with backscattered electron imaging (SEM-BSE). At last, chemical analysis and elemental mapping of the mineral bone composition were generated using a microanalytical system based on energy-dispersive and X-ray spectrometry (EDX). A total of 160 fracture tests were performed. The fracture resistance increased in mandible and femur with a higher accumulated dose of zoledronic acid. Statistically significant differences were recorded versus the controls with all the studies groups. The chemical analysis in mandible showed a significantly increased of calcium and phosphorous to compare the control with all of the study groups; however, in femur no statistically significant differences between the four study groups were observed. The administration of bisphosphonates increases the fracture resistance in mandible and femur.
Jenkins, Christine R; Eriksson, Göran; Bateman, Eric D; Reddel, Helen K; Sears, Malcolm R; Lindberg, Magnus; O'Byrne, Paul M
2017-04-20
Asthma management may involve a step up in treatment when symptoms are not well controlled. We examined whether budesonide/formoterol maintenance and reliever therapy (MRT) is as effective as higher, fixed-dose budesonide plus as-needed terbutaline in patients requiring step-up from Step 2 treatment (low-dose inhaled corticosteroids), stratified by baseline reliever use. A post-hoc analysis utilized data from three clinical trials of 6-12 months' duration. Patients aged ≥12 years with symptomatic asthma uncontrolled despite Step 2 treatment were included. Severe exacerbation rate, lung function and reliever use were analysed, stratified by baseline reliever use (<1, 1-2 and >2 occasions/day). Overall, 1239 patients were included. Reductions in severe exacerbation rate with budesonide/formoterol MRT versus fixed-dose budesonide were similar across baseline reliever use levels, and were statistically significant in patients using 1-2 (42%, p = 0.01) and >2 (39%, p = 0.02) reliever occasions/day, but not <1 reliever occasion/day (35%, p = 0.11). Both treatments significantly increased mean FEV 1 from baseline; improvements were significantly greater for budesonide/formoterol MRT in all reliever use groups. Reductions in reliever use from baseline were significantly greater with budesonide/formoterol MRT versus fixed-dose budesonide in patients using 1-2 and >2 reliever occasions/day (-0.33 and -0.74 occasions/day, respectively). Treatment benefit with budesonide/formoterol MRT versus higher, fixed-dose budesonide plus short-acting β 2 -agonist was found in Step 2 patients with relatively low reliever use, supporting the proposal that budesonide/formoterol MRT may be useful when asthma is uncontrolled with low-dose inhaled corticosteroid.
Novel oxytocin receptor variants in laboring women requiring high doses of oxytocin.
Reinl, Erin L; Goodwin, Zane A; Raghuraman, Nandini; Lee, Grace Y; Jo, Erin Y; Gezahegn, Beakal M; Pillai, Meghan K; Cahill, Alison G; de Guzman Strong, Cristina; England, Sarah K
2017-08-01
Although oxytocin commonly is used to augment or induce labor, it is difficult to predict its effectiveness because oxytocin dose requirements vary significantly among women. One possibility is that women requiring high or low doses of oxytocin have variations in the oxytocin receptor gene. To identify oxytocin receptor gene variants in laboring women with low and high oxytocin dosage requirements. Term, nulliparous women requiring oxytocin doses of ≤4 mU/min (low-dose-requiring, n = 83) or ≥20 mU/min (high-dose-requiring, n = 104) for labor augmentation or induction provided consent to a postpartum blood draw as a source of genomic DNA. Targeted-amplicon sequencing (coverage >30×) with MiSeq (Illumina) was performed to discover variants in the coding exons of the oxytocin receptor gene. Baseline relevant clinical history, outcomes, demographics, and oxytocin receptor gene sequence variants and their allele frequencies were compared between low-dose-requiring and high-dose-requiring women. The Scale-Invariant Feature Transform algorithm was used to predict the effect of variants on oxytocin receptor function. The Fisher exact or χ 2 tests were used for categorical variables, and Student t tests or Wilcoxon rank sum tests were used for continuous variables. A P value < .05 was considered statistically significant. The high-dose-requiring women had greater rates of obesity and diabetes and were more likely to have undergone labor induction and required prostaglandins. High-dose-requiring women were more likely to undergo cesarean delivery for first-stage arrest and less likely to undergo cesarean delivery for nonreassuring fetal status. Targeted sequencing of the oxytocin receptor gene in the total cohort (n = 187) revealed 30 distinct coding variants: 17 nonsynonymous, 11 synonymous, and 2 small structural variants. One novel variant (A243T) was found in both the low- and high-dose-requiring groups. Three novel variants (Y106H, A240_A249del, and P197delfs*206) resulting in an amino acid substitution, loss of 9 amino acids, and a frameshift stop mutation, respectively, were identified only in low-dose-requiring women. Nine nonsynonymous variants were unique to the high-dose-requiring group. These included 3 known variants (R151C, G221S, and W228C) and 6 novel variants (M133V, R150L, H173R, A248V, G253R, and I266V). Of these, R150L, R151C, and H173R were predicted by Scale-Invariant Feature Transform algorithm to damage oxytocin receptor function. There was no statistically significant association between the numbers of synonymous and nonsynonymous substitutions in the patient groups. Obesity, diabetes, and labor induction were associated with the requirement for high doses of oxytocin. We did not identify significant differences in the prevalence of oxytocin receptor variants between low-dose-requiring and high-dose-requiring women, but novel oxytocin receptor variants were enriched in the high-dose-requiring women. We also found 3 oxytocin receptor variants (2 novel, 1 known) that were predicted to damage oxytocin receptor function and would likely increase an individual's risk for requiring a high oxytocin dose. Further investigation of oxytocin receptor variants and their effects on protein function will inform precision medicine in pregnant women. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L
2009-02-01
To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.
SU-E-T-29: A Web Application for GPU-Based Monte Carlo IMRT/VMAT QA with Delivered Dose Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Folkerts, M; University of California, San Diego, La Jolla, CA; Graves, Y
Purpose: To enable an existing web application for GPU-based Monte Carlo (MC) 3D dosimetry quality assurance (QA) to compute “delivered dose” from linac logfile data. Methods: We added significant features to an IMRT/VMAT QA web application which is based on existing technologies (HTML5, Python, and Django). This tool interfaces with python, c-code libraries, and command line-based GPU applications to perform a MC-based IMRT/VMAT QA. The web app automates many complicated aspects of interfacing clinical DICOM and logfile data with cutting-edge GPU software to run a MC dose calculation. The resultant web app is powerful, easy to use, and is ablemore » to re-compute both plan dose (from DICOM data) and delivered dose (from logfile data). Both dynalog and trajectorylog file formats are supported. Users upload zipped DICOM RP, CT, and RD data and set the expected statistic uncertainty for the MC dose calculation. A 3D gamma index map, 3D dose distribution, gamma histogram, dosimetric statistics, and DVH curves are displayed to the user. Additional the user may upload the delivery logfile data from the linac to compute a 'delivered dose' calculation and corresponding gamma tests. A comprehensive PDF QA report summarizing the results can also be downloaded. Results: We successfully improved a web app for a GPU-based QA tool that consists of logfile parcing, fluence map generation, CT image processing, GPU based MC dose calculation, gamma index calculation, and DVH calculation. The result is an IMRT and VMAT QA tool that conducts an independent dose calculation for a given treatment plan and delivery log file. The system takes both DICOM data and logfile data to compute plan dose and delivered dose respectively. Conclusion: We sucessfully improved a GPU-based MC QA tool to allow for logfile dose calculation. The high efficiency and accessibility will greatly facilitate IMRT and VMAT QA.« less
Widmann, G; Juranek, D; Waldenberger, F; Schullian, P; Dennhardt, A; Hoermann, R; Steurer, M; Gassner, E-M; Puelacher, W
2017-08-01
Dose reduction on CT scans for surgical planning and postoperative evaluation of midface and orbital fractures is an important concern. The purpose of this study was to evaluate the variability of various low-dose and iterative reconstruction techniques on the visualization of orbital soft tissues. Contrast-to-noise ratios of the optic nerve and inferior rectus muscle and subjective scores of a human cadaver were calculated from CT with a reference dose protocol (CT dose index volume = 36.69 mGy) and a subsequent series of low-dose protocols (LDPs I-4: CT dose index volume = 4.18, 2.64, 0.99, and 0.53 mGy) with filtered back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR)-50, ASIR-100, and model-based iterative reconstruction. The Dunn Multiple Comparison Test was used to compare each combination of protocols (α = .05). Compared with the reference dose protocol with FBP, the following statistically significant differences in contrast-to-noise ratios were shown (all, P ≤ .012) for the following: 1) optic nerve: LDP-I with FBP; LDP-II with FBP and ASIR-50; LDP-III with FBP, ASIR-50, and ASIR-100; and LDP-IV with FBP, ASIR-50, and ASIR-100; and 2) inferior rectus muscle: LDP-II with FBP, LDP-III with FBP and ASIR-50, and LDP-IV with FBP, ASIR-50, and ASIR-100. Model-based iterative reconstruction showed the best contrast-to-noise ratio in all images and provided similar subjective scores for LDP-II. ASIR-50 had no remarkable effect, and ASIR-100, a small effect on subjective scores. Compared with a reference dose protocol with FBP, model-based iterative reconstruction may show similar diagnostic visibility of orbital soft tissues at a CT dose index volume of 2.64 mGy. Low-dose technology and iterative reconstruction technology may redefine current reference dose levels in maxillofacial CT. © 2017 by American Journal of Neuroradiology.
Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters
NASA Astrophysics Data System (ADS)
Wang, Jing; Lu, Hongbing; Li, Tianfang; Liang, Zhengrong
2005-04-01
Low-dose CT (computed tomography) sinogram data have been shown to be signal-dependent with an analytical relationship between the sample mean and sample variance. Spatially-invariant low-pass linear filters, such as the Butterworth and Hanning filters, could not adequately handle the data noise and statistics-based nonlinear filters may be an alternative choice, in addition to other choices of minimizing cost functions on the noisy data. Anisotropic diffusion filter and nonlinear Gaussian filters chain (NLGC) are two well-known classes of nonlinear filters based on local statistics for the purpose of edge-preserving noise reduction. These two filters can utilize the noise properties of the low-dose CT sinogram for adaptive noise reduction, but can not incorporate signal correlative information for an optimal regularized solution. Our previously-developed Karhunen-Loeve (KL) domain PWLS (penalized weighted least square) minimization considers the signal correlation via the KL strategy and seeks the PWLS cost function minimization for an optimal regularized solution for each KL component, i.e., adaptive to the KL components. This work compared the nonlinear filters with the KL-PWLS framework for low-dose CT application. Furthermore, we investigated the nonlinear filters for post KL-PWLS noise treatment in the sinogram space, where the filters were applied after ramp operation on the KL-PWLS treated sinogram data prior to backprojection operation (for image reconstruction). By both computer simulation and experimental low-dose CT data, the nonlinear filters could not outperform the KL-PWLS framework. The gain of post KL-PWLS edge-preserving noise filtering in the sinogram space is not significant, even the noise has been modulated by the ramp operation.
Chen, Yingying; Liu, Peng; Chen, Xia; Li, Yanan; Zhang, Fengmei; Wang, Yangang
2018-05-01
There is a lack of research on the effect of low dose of angiotensin receptor blockers combined with spironolactone, and the effect of high dose of angiotensin receptor blockers alone on the urinary albumin excretion rate (UAER) in elderly patients with early type 2 diabetic nephropathy (DN). We conducted a prospective, randomized, open-label, parallel-controlled study that included 244 elderly patients with early DN and mild-to-moderate essential hypertension. Patients were randomly divided into 4 groups: low-dose irbesartan (group A), high-dose irbesartan (group B), low-dose irbesartan combined with spironolactone (group C) and high-dose irbesartan combined with spironolactone (group D). Changes in UAER, serum potassium and blood pressure were compared. There were no statistical differences in the baseline characteristics among groups. Furthermore, no significant difference in blood pressure before and after treatment was found among different groups. After 72-week treatment, UAER in group D was lower compared to group A and B (P < 0.05). Meanwhile, compared with group B, UAER in group C decreased significantly (P < 0.05). Additionally, significantly higher serum potassium was found in group D compared to other groups (P < 0.05). Also, group D had the highest count of patients who withdrew from the study due to hyperkalemia compared to other groups (P < 0.05). Our results indicate high-dose irbesartan combined with spironolactone may be more efficient in reducing UAER in elderly patients with early DN, but this treatment could cause hyperkalemia. Low-dose irbesartan combined with spironolactone was shown to be safer and more effective in decreasing UAER compared to high-dose irbesartan. Copyright © 2018 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Effective Dose in Nuclear Medicine Studies and SPECT/CT: Dosimetry Survey Across Quebec Province.
Charest, Mathieu; Asselin, Chantal
2018-06-01
The aims of the current study were to draw a portrait of the delivered dose in selected nuclear medicine studies in Québec province and to assess the degree of change between an earlier survey performed in 2010 and a later survey performed in 2014. Methods: Each surveyed nuclear medicine department had to complete 2 forms: the first, about the administered activity in selected nuclear medicine studies, and the second, about the CT parameters used in SPECT/CT imaging, if available. The administered activities were converted into effective doses using the most recent conversion factors. Diagnostic reference levels were computed for each imaging procedure to obtain a benchmark for comparison. Results: The distributions of administered activity in various nuclear medicine studies, along with the corresponding distribution of the effective doses, were determined. Excluding 131 I for thyroid studies, 67 Ga-citrate for infectious workups, and combined stress and rest myocardial perfusion studies, the remainder of the 99m Tc-based studies delivered average effective doses clustered below 10 mSv. Between the 2010 survey and the 2014 survey, there was a statistically significant decrease in delivered dose from 18.3 to 14.5 mSv. 67 Ga-citrate studies for infectious workups also showed a significant decrease in delivered dose from 31.0 to 26.2 mSv. The standardized CT portion of SPECT/CT studies yielded a mean effective dose 14 times lower than the radiopharmaceutical portion of the study. Conclusion: Between 2010 and 2014, there was a significant decrease in the delivered effective dose in myocardial perfusion and 67 Ga-citrate studies. The CT portions of the surveyed SPECT/CT studies contributed a relatively small fraction of the total delivered effective dose. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barbiero, Sara; Specialty School in Medical Physics, University of Pisa, Pisa; Rink, Alexandra
2016-01-01
Purpose: To report on single-fraction stereotactic body radiotherapy (RT) (SBRT) with flattening filter (FF)–free (FFF) volumetric modulated arc therapy (VMAT) for lung cancer and to compare dosimetric results with VMAT with FF. Methods and materials: Overall, 25 patients were treated with 6-MV FFF VMAT (Varian TrueBeam STx LINAC) to a prescribed dose of 24 Gy in a single fraction. Treatment plans were recreated using FF VMAT. Dose-volume indices, monitor units (MU), and treatment times were compared between FFF and FF VMAT techniques. Results: Dose constraints to PTV, spinal cord, and lungs were reached in FFF and FF plans. In FFFmore » plans, average conformity index was 1.13 (95% CI: 1.07 to1.38). Maximum doses to spinal cord, heart, esophagus, and trachea were 2.9 Gy (95% CI: 0.4 to 6.7 Gy), 0.8 Gy (95% CI: 0 to 3.6 Gy), 3.3 Gy (95% CI: 0.02 to 13.9 Gy), and 1.5 Gy (95% CI: 0 to 4.9 Gy), respectively. Average V7 Gy, V7.4 Gy, and mean dose to the healthy lung were 126.5 cc (95% CI: 41.3 to 248.9 cc), 107.3 cc (95% CI: 18.7 to 232.8 cc), and 1.1 Gy (95% CI: 0.3 to 2.2 Gy), respectively. No statistically significant differences were found in dosimetric results and MU between FF and FFF treatments. Treatment time was reduced by an average factor of 2.31 (95% CI: 2.15 to 2.43) from FF treatments to FFF, and the difference was statistically significant. Conclusions: FFF VMAT for lung SBRT provides equivalent dosimetric results to the target and organs at risk as FF VMAT while significantly reducing treatment time.« less
Mason, W D
1980-11-01
Eighteen healthy volunteers were administered single doses of commercially available solid dosage forms of aspirin, magnesium salicylate (I), and choline magnesium trisalicylate (II), equivalent to approximately 500 mg of salicylic acid, in a randomized, complete crossover design. Plasma salicylate and urine salicylurate levels were measured by high-pressure liquid chromatography at frequent intervals following dosing; the resultant profiles, areas under the curve (AUC), and percentages of dose excreted as salicylurate were statistically analyzed by an analysis of variance. The plasma salicylate levels following the two dosage forms containing I and II were virtually identical when corrected for small differences in the dose. The plasma salicylic acid level following aspirin was approximately 10% lower during the 1.5--3.0-hr interval due to a portion of unhydrolyzed aspirin, but the dose-corrected AUC for the products tested did not differ significantly (p < 0.05). During the 24 hr following dosing, 66.5 +/- 12.1 68.4 +/- 7.1, and 60.9 +/- 14.1% of the salicylic acid were excreted as urine salicylurate for aspirin, I, and II, respectively, with no significant difference (p < 0.05). Based on this study, there are no significant differences in the rate and extent of absorption of salicylate following the three dosage forms tested, and the elimination kinetics of salicylic acid are not altered by these dosage forms.
Incidence of cerebral infarction after radiotherapy for pituitary adenoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flickinger, J.C.; Nelson, P.B.; Taylor, F.H.
1989-06-15
The incidence of cerebral infarction was studied in 156 patients irradiated for treatment of pituitary adenomas. Seven patients experienced strokes at intervals of 3.2 to 14.6 years after irradiation. The observed incidence was not significantly greater than the expected value of 3.5 strokes (P = 0.078). Six strokes occurred in patients receiving equivalent doses (ED) of 1070 ret or more (observed to expected ratio 3.87, significantly elevated; P less than 0.001). Univariate log-rank analysis showed that the risk of stroke was significantly higher (P = 0.010) in patients receiving an ED of 1070 ret or more (4180 cGy/22 fractions) thanmore » those receiving lower doses. Multivariate analysis, however, demonstrated that the increased risk of stroke was associated only with increasing age (P less than 0.0001), not ED (P = 0.148). Due to these inconsistent statistical results, no definitive conclusions could be reached about the relationship between radiation dose to the pituitary and subsequent cerebral infarction.« less
Johanson, J F; Ueno, R
2007-06-01
Lubiprostone, a locally acting type-2 chloride channel activator, induces intestinal fluid secretion. To assess efficacy and safety of oral lubiprostone at multiple doses for the treatment of chronic constipation. A total of 129 patients with chronic constipation were randomized to receive lubiprostone (24, 48 or 72 mcg/day) or placebo for 3 weeks. Spontaneous bowel movement (SBM) frequency, rescue medication use, symptom assessments and adverse events (AEs) were tracked. Over the double-blinded period, mean SBM frequencies were higher for lubiprostone groups (5.1-6.1) vs. placebo (3.8) and the overall difference was statistically significant (P = 0.046). SBM frequencies at week 1 were significantly higher in patients taking lubiprostone 48 or 72 mcg/day (P < or = 0.003) and, at week 2, all three lubiprostone doses yielded significantly higher SBM rates vs. placebo (P < or = 0.020). Significantly larger proportions of patients taking lubiprostone 48 and 72 mcg/day also experienced a SBM on the first treatment day (P < or = 0.009). The most common AEs were nausea, headache and diarrhoea. Lubiprostone improved SBM rates in a dose-dependent manner. AEs were tolerable for most patients. Increased AE severity at 72 mcg/day did not provide a clear risk-to-benefit advantage compared with lubiprostone 48 mcg/day, the dose chosen for subsequent Phase 3 studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Emiliano C. C. Pozzi; Veronica A. Trivilin; Lucas L. Colombo
Boron neutron capture therapy (BNCT) was proposed for untreatable colorectal liver metastases. Employing an experimental model of liver metastases in rats, we recently demonstrated that BNCT mediated by boronophenylalanine (BPA-BNCT) at 13 Gy prescribed to tumor is therapeutically useful at 3-week follow-up. The aim of the present study was to evaluate dose–response at 5-week follow-up, based on retrospective dose assessment in individual rats. BDIX rats were inoculated with syngeneic colon cancer cells DHD/K12/TRb. Tumor-bearing animals were divided into three groups: BPA-BNCT (n = 19), Beam only (n = 8) and Sham (n = 7) (matched manipulation, no treatment). For eachmore » rat, neutron flux was measured in situ and boron content was measured in a pre-irradiation blood sample for retrospective individual dose assessment. For statistical analysis (ANOVA), individual data for the BPA-BNCT group were pooled according to absorbed tumor dose, BPA-BNCT I: 4.5–8.9 Gy and BPA-BNCT II: 9.2–16 Gy. At 5 weeks post-irradiation, the tumor surface area post-treatment/pre-treatment ratio was 12.2 +/- 6.6 for Sham, 7.8 +/- 4.1 for Beam only, 4.4 +/- 5.6 for BPA-BNCT I and 0.45 +/- 0.20 for BPA-BNCT II; tumor nodule weight was 750 +/- 480 mg for Sham, 960 +/- 620 mg for Beam only, 380 +/- 720 mg for BPA-BNCT I and 7.3 +/- 5.9 mg for BPA-BNCT II. The BPA-BNCT II group exhibited statistically significant tumor control with no contributory liver toxicity. Potential threshold doses for tumor response and significant tumor control were established at 6.1 and 9.2 Gy, respectively.« less
Grazuleviciene, Regina; Kapustinskiene, Violeta; Vencloviene, Jone; Buinauskiene, Jurate; Nieuwenhuijsen, Mark J
2013-01-01
Objectives Congenital anomalies have been inconsistently associated with maternal crude estimated exposure to drinking water trihalomethane (THM). We investigated the relationship between individual THM uptake during the first trimester of pregnancy and congenital anomalies. Methods We estimated maternal THM uptake for 3074 live births using residential tap water concentrations, drinking water ingestion, showering and bathing, and uptake factors of THM in the blood. Multiple logistic regression was used to investigate the association of THM exposure with congenital anomalies. Results We observed no statistically significant relationships between congenital anomalies and the total THM internal dose. We found little indication of a dose-response relationship for brominated THM and congenital heart anomalies. The relationship was statistically significant for bromodichloromethane (BDCM) (OR=2.16, 95% CI 1.05 to 4.46, highest vs lowest tertile) during the first month of pregnancy. During the first trimester of pregnancy, the probability of developing heart anomalies increased for every 0.1 μg/d increase in the BDCM and for every 0.01 μg/d increase in the internal dibromochloromethane (DBCM) dose (OR 1.70, 95% CI 1.09 to 2.66, and OR 1.25, 95% CI 1.01 to 1.54, respectively). A dose-response relationship was evident for musculoskeletal anomalies and DBCM exposure during the first and second months of pregnancy, while BDCM exposure tended to increase the risk of urogenital anomalies. Conclusions This study shows some evidence for an association between the internal dose of THM and the risk of congenital anomalies. In particular, increased prenatal exposure to brominated THM might increase the risk of congenital heart and musculoskeletal anomalies. PMID:23404756
Park, Jong In; Park, Jong Min; Kim, Jung-In; Park, So-Yeon; Ye, Sung-Joon
2015-12-01
The aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT). Twenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose-volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences. Considerable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = -0.712, -0.628 and -0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose-volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria. Local gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, Andrew, E-mail: aojones@geisinger.edu; Treas, Jared; Yavoich, Brian
2014-01-01
The aim of the study was to investigate the differences between intraoperative and postoperative dosimetry for transrectal ultrasound–guided transperineal prostate implants using cesium-131 ({sup 131}Cs). Between 2006 and 2010, 166 patients implanted with {sup 131}Cs had both intraoperative and postoperative dosimetry studies. All cases were monotherapy and doses of 115 were prescribed to the prostate. The dosimetric properties (D{sub 90}, V{sub 150}, and V{sub 100} for the prostate) of the studies were compared. Two conformity indices were also calculated and compared. Finally, the prostate was automatically sectioned into 6 sectors (anterior and posterior sectors at the base, midgland, and apex)more » and the intraoperative and postoperative dosimetry was compared in each individual sector. Postoperative dosimetry showed statistically significant changes (p < 0.01) in every dosimetric value except V{sub 150}. In each significant case, the postoperative plans showed lower dose coverage. The conformity indexes also showed a bimodal frequency distribution with the index indicating poorer dose conformity in the postoperative plans. Sector analysis revealed less dose coverage postoperatively in the base and apex sectors with an increase in dose to the posterior midgland sector. Postoperative dosimetry overall and in specific sectors of the prostate differs significantly from intraoperative planning. Care must be taken during the intraoperative planning stage to ensure complete dose coverage of the prostate with the understanding that the final postoperative dosimetry will show less dose coverage.« less
Chacra, A R; Tan, G H; Apanovitch, A; Ravichandran, S; List, J; Chen, R
2009-01-01
Aims: Assess the efficacy and safety of saxagliptin added to a submaximal sulphonylurea dose vs. uptitration of sulphonylurea monotherapy in patients with type 2 diabetes and inadequate glycaemic control with sulphonylurea monotherapy. Methods and patients: A total of 768 patients (18–77 years; HbA1c screening ≥ 7.5 to ≤ 10.0%) were randomised and treated with saxagliptin 2.5 or 5 mg in combination with glyburide 7.5 mg vs. glyburide 10 mg for 24 weeks. Blinded uptitration glyburide was allowed in the glyburide-only arm to a maximum total daily dose of 15 mg. Efficacy analyses were performed using ANCOVA and last-observation-carried-forward methodology. Results: At week 24, 92% of glyburide-only patients were uptitrated to a total glyburide dose of 15 mg/day. Saxagliptin 2.5 and 5 mg provided statistically significant adjusted mean decreases from baseline to week 24 vs. uptitrated glyburide, respectively, in HbA1c (−0.54%, −0.64% vs. +0.08%; both p < 0.0001) and fasting plasma glucose (−7, −10 vs. +1 mg/dl; p = 0.0218 and p = 0.002). The proportion of patients achieving an HbA1c < 7% was greater for saxagliptin 2.5 and 5 mg vs. uptitrated glyburide (22.4% and 22.8% vs. 9.1%; both p < 0.0001). Postprandial glucose area under the curve was reduced for saxagliptin 2.5 and 5 mg vs. uptitrated glyburide (−4296 and −5000 vs. +1196 mg·min/dl; both p < 0.0001). Adverse event occurrence was similar across all groups. Reported hypoglycaemic events were not statistically significantly different for saxagliptin 2.5 (13.3%) and 5 mg (14.6%) vs. uptitrated glyburide (10.1%). Conclusion: Saxagliptin added to submaximal glyburide therapy led to statistically significant improvements vs. uptitration of glyburide alone across key glycaemic parameters and was generally well tolerated. PMID:19614786
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul, Jijo; Yang, Cungeng; Wu, Hui
Purpose: To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Methods and Materials: Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from themore » daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. Results: During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R{sup 2} > 0.99) and correlates weakly with the change in GTV (R{sup 2} = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Conclusion: Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer.« less
Wang, Juanqi; Hu, Weigang; Yang, Zhaozhi; Chen, Xiaohui; Wu, Zhiqiang; Yu, Xiaoli; Guo, Xiaomao; Lu, Saiquan; Li, Kaixuan; Yu, Gongyi
2017-05-22
Knowledge-based planning (KBP) is a promising technique that can improve plan quality and increase planning efficiency. However, no attempts have been made to extend the domain of KBP for planners with different planning experiences so far. The purpose of this study was to quantify the potential gains for planners with different planning experiences after implementing KBP in intensity modulated radiation therapy (IMRT) plans for left-sided breast cancer patients. The model libraries were populated with 80 expert clinical plans from treated patients who previously received left-sided breast-conserving surgery and IMRT with simultaneously integrated boost. The libraries were created on the RapidPlan TM . 6 planners with different planning experiences (2 beginner planners, 2 junior planners and 2 senior planners) generated manual and KBP optimized plans for additional 10 patients, similar to those included in the model libraries. The plan qualities were compared between manual and KBP plans. All plans were capable of achieving the prescription requirement. There were almost no statistically significant differences in terms of the planning target volume (PTV) coverage and dose conformality. It was demonstrated that the doses for most of organs-at-risk (OARs) were on average lower or equal in KBP plans compared to manual plans except for the senior planners, where the very small differences were not statistically significant. KBP data showed a systematic trend to have superior dose sparing at most parameters for the heart and ipsilateral lung. The observed decrease in the doses to these OARs could be achieved, particularly for the beginner and junior planners. Many differences were statistically significant. It is feasible to generate acceptable IMRT plans after implementing KBP for left-sided breast cancer. KBP helps to effectively improve the quality of IMRT plans against the benchmark of manual plans for less experienced planners without any manual intervention. KBP showed promise for homogenizing the plan quality by transferring planning expertise from more experienced to less experienced planners.
Paul, Jijo; Yang, Cungeng; Wu, Hui; Tai, An; Dalah, Entesar; Zheng, Cheng; Johnstone, Candice; Kong, Feng-Ming; Gore, Elizabeth; Li, X Allen
2017-06-01
To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from the daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R 2 > 0.99) and correlates weakly with the change in GTV (R 2 = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Y; Liao, Z; Jiang, W
Purpose: To evaluate the feasibility of using an automatic segmentation tool to delineate cardiac substructures from computed tomography (CT) images for cardiac toxicity analysis for non-small cell lung cancer (NSCLC) patients after radiotherapy. Methods: A multi-atlas segmentation tool developed in-house was used to delineate eleven cardiac substructures including the whole heart, four heart chambers, and six greater vessels automatically from the averaged 4DCT planning images for 49 NSCLC patients. The automatic segmented contours were edited appropriately by two experienced radiation oncologists. The modified contours were compared with the auto-segmented contours using Dice similarity coefficient (DSC) and mean surface distance (MSD)more » to evaluate how much modification was needed. In addition, the dose volume histogram (DVH) of the modified contours were compared with that of the auto-segmented contours to evaluate the dosimetric difference between modified and auto-segmented contours. Results: Of the eleven structures, the averaged DSC values ranged from 0.73 ± 0.08 to 0.95 ± 0.04 and the averaged MSD values ranged from 1.3 ± 0.6 mm to 2.9 ± 5.1mm for the 49 patients. Overall, the modification is small. The pulmonary vein (PV) and the inferior vena cava required the most modifications. The V30 (volume receiving 30 Gy or above) for the whole heart and the mean dose to the whole heart and four heart chambers did not show statistically significant difference between modified and auto-segmented contours. The maximum dose to the greater vessels did not show statistically significant difference except for the PV. Conclusion: The automatic segmentation of the cardiac substructures did not require substantial modification. The dosimetric evaluation showed no statistically significant difference between auto-segmented and modified contours except for the PV, which suggests that auto-segmented contours for the cardiac dose response study are feasible in the clinical practice with a minor modification to the PV vessel.« less
The efficacy of tranexamic acid and corticosteroid on edema and ecchymosis in septorhinoplasty.
Sakallioğlu, Öner; Polat, Cahit; Soylu, Erkan; Düzer, Sertaç; Orhan, İsrafil; Akyiğit, Abdulvahap
2015-04-01
The aim of this study was to investigate the efficacy of tranexamic acid (TA) and methylprednisolone on periorbital edema, ecchymosis, and intraoperative bleeding in patients who underwent open septorhinoplasty (oSRP). Seventy-five patients performing hump extraction and osteotomies were allocated into 3 groups as follows: group 1, 25 patients as control; group 2, 25 patients who were administered oral TA as first dose 1 g starting 2 hours before surgery, 3 g daily in divided doses (1 g, every 8 hours) for 5 days; and group 3, 25 patients who were administered a single dose of 1 mg/kg intravenous methylprednisolone at the beginning of the surgery. Operation time, amount of intraoperative bleeding, and complications were recorded. Scoring of eyelid edema and periorbital ecchymosis was evaluated on postoperative first, third, and seventh days using scale of 0 to 4 by 2 observers. In groups using TA and methylprednisolone, periorbital edema and ecchymosis scores were significantly lower compared with the control group (P < 0.05). No significant difference was seen clinically and statistically in preventing or decreasing both periorbital edema and ecchymosis between group 2 and group 3. Patients given TA showed significantly less intraoperative bleeding compared with controls and patients who were administered methylprednisolone. We observed that the administration of methylprednisolone significantly decreases periorbital edema and ecchymosis. Additionally, our results support that TA use in patients who underwent oSRP with osteotomies was found clinically and statistically effective for prevention of bleeding during oSRP operations and reduction of both periorbital edema and ecchymosis.
High-dose transdermal nicotine replacement for tobacco cessation.
Brokowski, Laurie; Chen, Jiahui; Tanner, Sara
2014-04-15
The safety and efficacy of high-dose transdermal nicotine-replacement therapy (NRT) for the treatment of tobacco-use cessation were reviewed. Transdermal nicotine doses of 7, 14, and 21 mg daily are approved by the Food and Drug Administration for use in tobacco cessation. However, studies have suggested that these doses are more adequate for people who smoke fewer than 20 cigarettes per day. A literature search was conducted to identify English-language studies that evaluated the use of transdermal nicotine doses of ≥42 mg daily. A total of 11 articles were identified, representing 10 separate trials. In terms of safety, the majority of the trials had no reports of serious adverse events related to transdermal NRT at doses of ≥42 mg daily. A dose-response relationship with adverse events occurred in most trials. In terms of efficacy, a numerically higher abstinence rate was achieved with high-dose transdermal NRT in all trials but 1. However, none of the studies showed significant differences in final abstinence rates at follow-up. Some reasons why statistical significance was not achieved in these trials may be related to the limitations of these trials, such as their small samples and the lack of a power calculation. A more robust trial is needed to support higher nicotine transdermal doses in tobacco cessation and to help elucidate which patient population would be most suitable for their use. The safety and efficacy of high-dose transdermal NRT for tobacco cessation have not been established in the medical literature.
High dose vitamin D may improve lower urinary tract symptoms in postmenopausal women.
Oberg, Johanna; Verelst, Margareta; Jorde, Rolf; Cashman, Kevin; Grimnes, Guri
2017-10-01
Lower urinary tract symptoms (LUTS) are common in postmenopausal women, and have been reported inversely associated with vitamin D intake and serum 25-hydroxyvitamin D (25(OH)D) levels. The aim of this study was to investigate if high dose vitamin D supplementation would affect LUTS in comparison to standard dose. In a randomized controlled study including 297 postmenopausal women with low bone mineral density, the participants were allocated to receive capsules of 20 000IU of vitamin D 3 twice a week (high dose group) or similar looking placebo (standard dose group). In addition, all the participants received 1g of calcium and 800IU of vitamin D daily. A validated questionnaire regarding LUTS was filled in at baseline and after 12 months. At baseline, 76 women in the high dose group and 82 in the standard dose group reported any LUTS. Levels of serum 25(OH)D increased significantly more in the high dose group (from 64.7 to 164.1nmol/l compared to from 64.1 to 81.8nmol/l, p<0.01). No differences between the groups were seen regarding change in LUTS except for a statistically significant reduction in the reported severity of urine incontinence in the high dose group as compared to the standard dose group after one year (p<0.05). The results need confirmation in a study specifically designed for this purpose. Copyright © 2017 Elsevier Ltd. All rights reserved.
Qu, Shu-Gen; Gao, Jin; Tang, Bo; Yu, Bo; Shen, Yue-Ping; Tu, Yu
2018-05-01
Low-dose ionizing radiation (LDIR) may increase the mortality of solid cancers in nuclear industry workers, but only few individual cohort studies exist, and the available reports have low statistical power. The aim of the present study was to focus on solid cancer mortality risk from LDIR in the nuclear industry using standard mortality ratios (SMRs) and 95% confidence intervals. A systematic literature search through the PubMed and Embase databases identified 27 studies relevant to this meta-analysis. There was statistical significance for total, solid and lung cancers, with meta-SMR values of 0.88, 0.80, and 0.89, respectively. There was evidence of stochastic effects by IR, but more definitive conclusions require additional analyses using standardized protocols to determine whether LDIR increases the risk of solid cancer-related mortality.
Multiple comparisons permutation test for image based data mining in radiotherapy.
Chen, Chun; Witte, Marnix; Heemsbergen, Wilma; van Herk, Marcel
2013-12-23
: Comparing incidental dose distributions (i.e. images) of patients with different outcomes is a straightforward way to explore dose-response hypotheses in radiotherapy. In this paper, we introduced a permutation test that compares images, such as dose distributions from radiotherapy, while tackling the multiple comparisons problem. A test statistic Tmax was proposed that summarizes the differences between the images into a single value and a permutation procedure was employed to compute the adjusted p-value. We demonstrated the method in two retrospective studies: a prostate study that relates 3D dose distributions to failure, and an esophagus study that relates 2D surface dose distributions of the esophagus to acute esophagus toxicity. As a result, we were able to identify suspicious regions that are significantly associated with failure (prostate study) or toxicity (esophagus study). Permutation testing allows direct comparison of images from different patient categories and is a useful tool for data mining in radiotherapy.
Cvrčková, Fatima; Luštinec, Jiří; Žárský, Viktor
2015-01-01
We usually expect the dose-response curves of biological responses to quantifiable stimuli to be simple, either monotonic or exhibiting a single maximum or minimum. Deviations are often viewed as experimental noise. However, detailed measurements in plant primary tissue cultures (stem pith explants of kale and tobacco) exposed to varying doses of sucrose, cytokinins (BA or kinetin) or auxins (IAA or NAA) revealed that growth and several biochemical parameters exhibit multiple reproducible, statistically significant maxima over a wide range of exogenous substance concentrations. This results in complex, non-monotonic dose-response curves, reminiscent of previous reports of analogous observations in both metazoan and plant systems responding to diverse pharmacological treatments. These findings suggest the existence of a hitherto neglected class of biological phenomena resulting in dose-response curves exhibiting periodic patterns of maxima and minima, whose causes remain so far uncharacterized, partly due to insufficient sampling frequency used in many studies.
NASA Astrophysics Data System (ADS)
Mavroidis, Panayiotis; Lind, Bengt K.; Theodorou, Kyriaki; Laurell, Göran; Fernberg, Jan-Olof; Lefkopoulos, Dimitrios; Kappas, Constantin; Brahme, Anders
2004-08-01
The purpose of this work is to provide some statistical methods for evaluating the predictive strength of radiobiological models and the validity of dose-response parameters for tumour control and normal tissue complications. This is accomplished by associating the expected complication rates, which are calculated using different models, with the clinical follow-up records. These methods are applied to 77 patients who received radiation treatment for head and neck cancer and 85 patients who were treated for arteriovenous malformation (AVM). The three-dimensional dose distribution delivered to esophagus and AVM nidus and the clinical follow-up results were available for each patient. Dose-response parameters derived by a maximum likelihood fitting were used as a reference to evaluate their compatibility with the examined treatment methodologies. The impact of the parameter uncertainties on the dose-response curves is demonstrated. The clinical utilization of the radiobiological parameters is illustrated. The radiobiological models (relative seriality and linear Poisson) and the reference parameters are validated to prove their suitability in reproducing the treatment outcome pattern of the patient material studied (through the probability of finding a worse fit, area under the ROC curve and khgr2 test). The analysis was carried out for the upper 5 cm of the esophagus (proximal esophagus) where all the strictures are formed, and the total volume of AVM. The estimated confidence intervals of the dose-response curves appear to have a significant supporting role on their clinical implementation and use.
Silber, J H; Fridman, M; DiPaola, R S; Erder, M H; Pauly, M V; Fox, K R
1998-07-01
If patients could be ranked according to their projected need for supportive care therapy, then more efficient and less costly treatment algorithms might be developed. This work reports on the construction of a model of neutropenia, dose reduction, or delay that rank-orders patients according to their need for costly supportive care such as granulocyte growth factors. A case series and consecutive sample of patients treated for breast cancer were studied. Patients had received standard-dose adjuvant chemotherapy for early-stage nonmetastatic breast cancer and were treated by four medical oncologists. Using 95 patients and validated with 80 additional patients, development models were constructed to predict one or more of the following events: neutropenia (absolute neutrophil count [ANC] < or = 250/microL), dose reduction > or = 15% of that scheduled, or treatment delay > or = 7 days. Two approaches to modeling were attempted. The pretreatment approach used only pretreatment predictors such as chemotherapy regimen and radiation history; the conditional approach included, in addition, blood count information obtained in the first cycle of treatment. The pretreatment model was unsuccessful at predicting neutropenia, dose reduction, or delay (c-statistic = 0.63). Conditional models were good predictors of subsequent events after cycle 1 (c-statistic = 0.87 and 0.78 for development and validation samples, respectively). The depth of the first-cycle ANC was an excellent predictor of events in subsequent cycles (P = .0001 to .004). Chemotherapy plus radiation also increased the risk of subsequent events (P = .0011 to .0901). Decline in hemoglobin (HGB) level during the first cycle of therapy was a significant predictor of events in the development study (P = .0074 and .0015), and although the trend was similar in the validation study, HGB decline failed to reach statistical significance. It is possible to rank patients according to their need of supportive care based on blood counts observed in the first cycle of therapy. Such rankings may aid in the choice of appropriate supportive care for patients with early-stage breast cancer.
A phenomenological biological dose model for proton therapy based on linear energy transfer spectra.
Rørvik, Eivind; Thörnqvist, Sara; Stokkevåg, Camilla H; Dahle, Tordis J; Fjaera, Lars Fredrik; Ytre-Hauge, Kristian S
2017-06-01
The relative biological effectiveness (RBE) of protons varies with the radiation quality, quantified by the linear energy transfer (LET). Most phenomenological models employ a linear dependency of the dose-averaged LET (LET d ) to calculate the biological dose. However, several experiments have indicated a possible non-linear trend. Our aim was to investigate if biological dose models including non-linear LET dependencies should be considered, by introducing a LET spectrum based dose model. The RBE-LET relationship was investigated by fitting of polynomials from 1st to 5th degree to a database of 85 data points from aerobic in vitro experiments. We included both unweighted and weighted regression, the latter taking into account experimental uncertainties. Statistical testing was performed to decide whether higher degree polynomials provided better fits to the data as compared to lower degrees. The newly developed models were compared to three published LET d based models for a simulated spread out Bragg peak (SOBP) scenario. The statistical analysis of the weighted regression analysis favored a non-linear RBE-LET relationship, with the quartic polynomial found to best represent the experimental data (P = 0.010). The results of the unweighted regression analysis were on the borderline of statistical significance for non-linear functions (P = 0.053), and with the current database a linear dependency could not be rejected. For the SOBP scenario, the weighted non-linear model estimated a similar mean RBE value (1.14) compared to the three established models (1.13-1.17). The unweighted model calculated a considerably higher RBE value (1.22). The analysis indicated that non-linear models could give a better representation of the RBE-LET relationship. However, this is not decisive, as inclusion of the experimental uncertainties in the regression analysis had a significant impact on the determination and ranking of the models. As differences between the models were observed for the SOBP scenario, both non-linear LET spectrum- and linear LET d based models should be further evaluated in clinically realistic scenarios. © 2017 American Association of Physicists in Medicine.
Kole, Thomas P; Aghayere, Osarhieme; Kwah, Jason; Yorke, Ellen D; Goodman, Karyn A
2012-08-01
To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D-CRT. Long-term studies are necessary to determine how this will impact on development of coronary artery disease and other cardiac complications. Copyright © 2012 Elsevier Inc. All rights reserved.
Ultraviolet radiation exposure of children and adolescents in Durban, South Africa.
Guy, Caradee; Diab, Roseanne; Martincigh, Bice
2003-03-01
The solar ultraviolet radiation (UVR) exposure of 30 children and adolescents in three age groups (4-6 years, 7-9 years and 13-14 years) was measured for 1 week in late summer (February-March) in Durban, South Africa, using UVR-sensitive polysulfone film badges (PSFB) attached to the lapel region of the body. The mean and median values for all ages over the study period were 2.0 and 1.2 standard erythemal dose (SED) units, respectively, where 1 SED = 100 J x m(-2). Individual PSFB doses were analyzed as a function of age, gender and behavior. No significant statistical differences were found between different age groups; however, there was a statistical difference between males and females, with males generally receiving higher PSFB doses. Subjects completed UVR exposure journals documenting their time outdoors, shade versus sun conditions, nature of their activities, clothing worn and their use of sunscreen for each day of the study. Activity patterns were noted as the most important factor influencing individual UVR dose. Ambient erythemal UVR was measured by a Yankee Environmental Systems UVB pyranometer, and a relationship between ambient UVR and individual UVR dose was derived. On average, subjects received a dose of 4.6% of the total daily erythemal UVR. Based on this factor, the potential dose of an individual over a full annual cycle was estimated. Accordingly, there were 139 days during the year when an individual with skin type I (light skin) would be likely to experience minimal erythema and 97 and 32 days for individuals with skin types II and III, respectively.
Du, Zhenhua; Qu, Hui
2017-03-01
In this study, the relationship between ovarian function and ovarian limited dose in radiotherapy was evaluated in young patients with cervical cancer who underwent ovarian transposition (Fig1B). Moreover, the novel ovarian dose limit for a better preservation of ovarian function in intensity-modulated radiation therapy (IMRT) was determined. We retrospectively analyzed data from 86 patients with cervical cancer who received radical hysterectomy and ovarian transposition from January 2013 to June 2015. In agreement with the National Comprehensive Cancer Network Guidelines (NCCN) for Cervical Cancer Version 2.2015, 65 patients with pathological high-risk factors were administered adjuvant radiotherapy-20 of them received three-dimensional conformal radiotherapy (Observation Group A), 24 patients received IMRT with no limitation on radiation dose to ovaries (Observation Group B), and 21 patients underwent IMRT with limited radiation dose(V 10 <20%) to ovaries (Observation Group C). Twenty-one patients without any predetermined high-risk factors did not received radiation therapy (Control Group D). Patients from all four groups were followed up, and sex hormone levels (E 2 , P, follicle-stimulating hormone [FSH], LH) before radiation, postradiation, 3 month, and 6 month after the radiation therapy were measured by electrochemiluminescence immunoassay. Subsequently, changes in sex hormone levels in all four groups of patients at various time points were analyzed. The levels of sexual hormones (E 2 , P, FSH, LH) before radiation, postradiation, 3 month, and 6 month after the radiation therapy in patients from all three observation groups were significantly lower than those in patients of the control group (P < 0.05). There was no statistically significant difference in the levels of sex hormones in patients of the control group at different time points (P > 0.05). Within each observation group, there was a statistically significant difference in the sex hormone levels in patients before the radiation and after the radiation (P < 0.05); however, when data from all three observation groups were compared, only the difference in the levels of FSH and LH between the patients from Group A and Group C was statistically significant (P < 0.05). The results of receiver-operating characteristic (ROC) curve analysis suggested that limiting ovarian radiation dose to V 7.5 < 26% in IMRT prevents the disruption of ovarian function (area under ROC curve was 0.740, confidence interval [CI] = 0.606-0.874). In young patients with cervical cancer who underwent radical hysterectomy and ovarian transposition without receiving adjuvant radiotherapy, ovarian endocrine function was well preserved. In patients who received any type of postoperative radiotherapy, ovarian function was affected, suggesting that the standard ovarian limited dose used in IMRT disrupted ovarian function. The results of the ROC curve analysis suggested that the new optimal dose limit of V 7.5 < 26% should be used in IMRT to preserve ovarian function (P = 0.003). © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fiandra, Christian; Fusella, Marco; Filippi, Andrea Riccardo
2013-08-15
Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered (up to 30 Gy). Gafchromic{sup TM} EBT2 and EBT3 films may be considered the dosimeter of choice, and the authors here provide some additional data about uniformity correction for this new generation of radiochromic films.Methods: A new analysis method using blue channel for marker dye correction was proposed for uniformity correction both for EBT2 and EBT3more » films. Symmetry, flatness, and field-width of a reference field were analyzed to provide an evaluation in a high-spatial resolution of the film uniformity for EBT3. Absolute doses were compared with thermoluminescent dosimeters (TLD) as baseline. VMAT plans with multiple noncoplanar arcs were generated with a treatment planning system on a selected pool of eleven patients with cranial lesions and then recalculated on a water-equivalent plastic phantom by Monte Carlo algorithm for patient-specific QA. 2D quantitative dose comparison parameters were calculated, for the computed and measured dose distributions, and tested for statistically significant differences.Results: Sensitometric curves showed a different behavior above dose of 5 Gy for EBT2 and EBT3 films; with the use of inhouse marker-dye correction method, the authors obtained values of 2.5% for flatness, 1.5% of symmetry, and a field width of 4.8 cm for a 5 × 5 cm{sup 2} reference field. Compared with TLD and selecting a 5% dose tolerance, the percentage of points with ICRU index below 1 was 100% for EBT2 and 83% for EBT3. Patients analysis revealed statistically significant differences (p < 0.05) between EBT2 and EBT3 in the percentage of points with gamma values <1 (p= 0.009 and p= 0.016); the percent difference as well as the mean difference between calculated and measured isodoses (20% and 80%) were found not to be significant (p= 0.074, p= 0.185, and p= 0.57).Conclusions: Excellent performances in terms of dose homogeneity were obtained using a new blue channel method for marker-dye correction on both EBT2 and EBT3 Gafchromic{sup TM} films. In comparison with TLD, the passing rates for the EBT2 film were higher than for EBT3; a good agreement with estimated data by Monte Carlo algorithm was found for both films, with some statistically significant differences again in favor of EBT2. These results suggest that the use of Gafchromic{sup TM} EBT2 and EBT3 films is appropriate for dose verification measurements in VMAT stereotactic radiosurgery; taking into account the uncertainty associated with Gafchromic film dosimetry, the use of adequate action levels is strongly advised, in particular, for EBT3.« less
Singh, Nagendra Madan; Sathyaprabha, T N; Thirthalli, Jagadisha; Andrade, Chittaranjan
2018-01-01
No electroconvulsive therapy (ECT) study on humans or in animal models has so far examined whether differently composed electrical stimuli exert different cardiac electrophysiological effects at constant electrical dose. The subject is important because cardiac electrophysiological changes may provide indirect information about ECT seizure quality as modulated by stimulus composition. Adult female Wistar rats ( n = 20/group) received fixed, moderately suprathreshold (18 mC) electrical stimuli. This stimulus in each of eight groups was formed by varying pulse amplitude, pulse width, pulse frequency, and stimulus duration. The electrocardiogram was recorded, and time and frequency domain variables were examined in 30 s epochs in preictal (30 s before electroconvulsive shock [ECS]), early postictal (starting 15 s after stimulation), and late postictal (5 h after ECS) periods. Alpha for statistical significance was set at P < 0.01 to adjust for multiple hypothesis testing. Cardiac electrophysiological indices in the eight groups did not differ significantly at baseline. At both early and late postictal time points, almost no analysis yielded statistically significant differences between groups for four time domain variables, including heart rate and standard deviation of R-R intervals, and for six frequency domain variables, including low-frequency power, high-frequency power, and total power. Cardiac electrophysiological measures may not be helpful to identify differences in seizure quality that are driven by differences in the composition of electrical stimuli at constant, moderately suprathreshold electrical dose. The generalization of this conclusion to threshold electrical doses and to human contexts requires a study.
Shenk, Eleni E; Bondi, Deborah S; Pellerite, Matthew M; Sriram, Sudhir
2018-01-01
The aim of this study was to evaluate the timing and dosing of caffeine therapy in relation to the development of bronchopulmonary dysplasia (BPD). This was a single-center, retrospective cohort study comparing early (days of life 0-2) to late (day of life 3 or greater) caffeine initiation in extremely low birth weight neonates, with a secondary analysis of large (10 mg/kg/day) to small dose (5 mg/kg/day) caffeine. There were 138 patients in the primary timing analysis. The early caffeine group had a lower incidence and reduced odds of the composite outcome of BPD or all-cause mortality, compared with the late caffeine group (64% vs. 88%, respectively; adjusted p < 0.05; adjusted OR 0.36 [95% CI 0.13-0.98]). No statistically significant difference was found between dosing groups (p = 0.29) in the primary outcome; however, there was a lower rate of patent ductus arteriosus requiring treatment (p = 0.05) and decreased likelihood of discharging home on oxygen (p = 0.02) in the large-dose group compared with the small-dose group. Early caffeine initiation significantly decreased the incidence of BPD or all-cause mortality in extremely low birth weight neonates. Patients receiving large-dose caffeine had improved secondary outcomes, although no difference in BPD was noted. Further studies are needed to determine the optimal dosing of caffeine.
Ozgen, Aytul; Hayran, Mutlu; Kahraman, Fatih
2012-11-01
The intention of this research was to define the predictive factors for acute esophagitis (AE) in lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy. The data for 72 lung cancer patients treated with concurrent chemoradiotherapy between 2008 and 2010 were prospectively evaluated. Mean lung dose, mean dose of esophagus, volume of esophagus irradiated and percentage of esophagus volume treated were analysed according to esophagitis grades. The mean esophageal dose was associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P < 0.001). However, the mean lung dose and the volume of esophagus irradiated were not associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P = 0.50 and P = 0.41, respectively). The mean radiation dose received by the esophagus was found to be highly correlated with the duration of Grade 2 esophagitis (Spearman test, r = 0.82, P < 0.001). The mean dose of esophagus ≥28 Gy showed statistical significance with respect to AE Grade 2 or worse (receiver operating characteristic curve analysis, 95% CI, 0.929-1.014). In conclusion, the mean esophageal dose was significantly associated with a risk of esophageal toxicity in patients with lung cancer treated with concurrent radiotherapy and chemotherapy.
Ozgen, Aytul; Hayran, Mutlu; Kahraman, Fatih
2012-01-01
The intention of this research was to define the predictive factors for acute esophagitis (AE) in lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy. The data for 72 lung cancer patients treated with concurrent chemoradiotherapy between 2008 and 2010 were prospectively evaluated. Mean lung dose, mean dose of esophagus, volume of esophagus irradiated and percentage of esophagus volume treated were analysed according to esophagitis grades. The mean esophageal dose was associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P < 0.001). However, the mean lung dose and the volume of esophagus irradiated were not associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P = 0.50 and P = 0.41, respectively). The mean radiation dose received by the esophagus was found to be highly correlated with the duration of Grade 2 esophagitis (Spearman test, r = 0.82, P < 0.001). The mean dose of esophagus ≥28 Gy showed statistical significance with respect to AE Grade 2 or worse (receiver operating characteristic curve analysis, 95% CI, 0.929–1.014). In conclusion, the mean esophageal dose was significantly associated with a risk of esophageal toxicity in patients with lung cancer treated with concurrent radiotherapy and chemotherapy. PMID:22915782
Duration of IOP reduction with travoprost BAK-free solution.
Gross, Ronald L; Peace, James H; Smith, Stephen E; Walters, Thomas R; Dubiner, Harvey B; Weiss, Mark J; Ochsner, Katherine I
2008-01-01
To compare the duration of action of travoprost ophthalmic solution 0.004% (Travatan Z) formulated without benzalkonium chloride (BAK) to travoprost ophthalmic solution 0.004% formulated with BAK (Travatan). This was a prospective, randomized, double-masked study. Patients with open-angle glaucoma or ocular hypertension were randomized to receive 2 weeks of once-daily therapy with travoprost BAK-free or travoprost with BAK. Patients received the last dose of medication on day 13 and then intraocular pressure (IOP) was assessed every 12 hours for 60 hours. Statistical analysis included change in IOP from baseline for each group and comparison of mean IOP between groups. Of the 109 patients enrolled, 106 patients completed the study. Untreated mean baseline IOP at 8 AM was 26.9 mm Hg in the travoprost BAK-free group and 27.1 mm Hg in the travoprost with BAK group. At 12, 24, 36, 48, and 60 hours after the last dose, mean IOP in the travoprost BAK-free group was 18.7, 17.2, 19.5, 18.7, and 20.8 mm Hg, respectively; whereas mean IOP in the travoprost with BAK group was 18.5, 16.8, 19.7, 18.0, and 20.8 mm Hg, respectively. Mean IOP at all time points after the last dose of medication was >6 mm Hg lower than the 8 AM baseline in both groups. Between-group differences were within +/-0.6 mm Hg at all postdose time points. There were no statistically significant differences between the 2 treatment groups at baseline or at any postdose time point. Drug-related side effects were uncommon, mild in intensity, and comparable between groups. Travoprost without BAK has similar IOP-lowering efficacy and safety compared with travoprost preserved with BAK. Both formulations of travoprost have a prolonged duration of action, with statistically and clinically significant reductions from baseline persisting up to 60 hours after the last dose.
Moser, V C; Casey, M; Hamm, A; Carter, W H; Simmons, J E; Gennings, C
2005-07-01
Environmental exposures generally involve chemical mixtures instead of single chemicals. Statistical models such as the fixed-ratio ray design, wherein the mixing ratio (proportions) of the chemicals is fixed across increasing mixture doses, allows for the detection and characterization of interactions among the chemicals. In this study, we tested for interaction(s) in a mixture of five organophosphorus (OP) pesticides (chlorpyrifos, diazinon, dimethoate, acephate, and malathion). The ratio of the five pesticides (full ray) reflected the relative dietary exposure estimates of the general population as projected by the US EPA Dietary Exposure Evaluation Model (DEEM). A second mixture was tested using the same dose levels of all pesticides, but excluding malathion (reduced ray). The experimental approach first required characterization of dose-response curves for the individual OPs to build a dose-additivity model. A series of behavioral measures were evaluated in adult male Long-Evans rats at the time of peak effect following a single oral dose, and then tissues were collected for measurement of cholinesterase (ChE) activity. Neurochemical (blood and brain cholinesterase [ChE] activity) and behavioral (motor activity, gait score, tail-pinch response score) endpoints were evaluated statistically for evidence of additivity. The additivity model constructed from the single chemical data was used to predict the effects of the pesticide mixture along the full ray (10-450 mg/kg) and the reduced ray (1.75-78.8 mg/kg). The experimental mixture data were also modeled and statistically compared to the additivity models. Analysis of the 5-OP mixture (the full ray) revealed significant deviation from additivity for all endpoints except tail-pinch response. Greater-than-additive responses (synergism) were observed at the lower doses of the 5-OP mixture, which contained non-effective dose levels of each of the components. The predicted effective doses (ED20, ED50) were about half that predicted by additivity, and for brain ChE and motor activity, there was a threshold shift in the dose-response curves. For the brain ChE and motor activity, there was no difference between the full (5-OP mixture) and reduced (4-OP mixture) rays, indicating that malathion did not influence the non-additivity. While the reduced ray for blood ChE showed greater deviation from additivity without malathion in the mixture, the non-additivity observed for the gait score was reversed when malathion was removed. Thus, greater-than-additive interactions were detected for both the full and reduced ray mixtures, and the role of malathion in the interactions varied depending on the endpoint. In all cases, the deviations from additivity occurred at the lower end of the dose-response curves.
Kauweloa, Kevin I; Gutierrez, Alonso N; Stathakis, Sotirios; Papanikolaou, Niko; Mavroidis, Panayiotis
2016-07-01
A toolkit has been developed for calculating the 3-dimensional biological effective dose (BED) distributions in multi-phase, external beam radiotherapy treatments such as those applied in liver stereotactic body radiation therapy (SBRT) and in multi-prescription treatments. This toolkit also provides a wide range of statistical results related to dose and BED distributions. MATLAB 2010a, version 7.10 was used to create this GUI toolkit. The input data consist of the dose distribution matrices, organ contour coordinates, and treatment planning parameters from the treatment planning system (TPS). The toolkit has the capability of calculating the multi-phase BED distributions using different formulas (denoted as true and approximate). Following the calculations of the BED distributions, the dose and BED distributions can be viewed in different projections (e.g. coronal, sagittal and transverse). The different elements of this toolkit are presented and the important steps for the execution of its calculations are illustrated. The toolkit is applied on brain, head & neck and prostate cancer patients, who received primary and boost phases in order to demonstrate its capability in calculating BED distributions, as well as measuring the inaccuracy and imprecision of the approximate BED distributions. Finally, the clinical situations in which the use of the present toolkit would have a significant clinical impact are indicated. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brock, K; Lee, C; Samuels, S
Purpose: Tools are now available to perform daily dose assessment in radiotherapy, however, guidance is lacking as to when to replan to limit increase in normal tissue dose. This work performs statistical analysis to provide guidance for when adaptive replanning may be necessary for head/neck (HN) patients. Methods: Planning CT and daily kVCBCT images for 50 HN patients treated with VMAT were retrospectively evaluated. Twelve of 50 patients were replanned due to anatomical changes noted over their RT course. Daily dose assessment was performed to calculate the variation between the planned and delivered dose for the 38 patients not replannedmore » and the patients replanned using their delivered plan. In addition, for the replanned patients, the dose that would have been delivered if the plan was not modified was also quantified. Deviations in dose were analyzed before and after replanning, the daily variations in patients who were not replanned assessed, and the predictive power of the deviation after 1, 5, and 15 fractions determined. Results: Dose deviations were significantly reduced following replanning, compared to if the original plan would have been delivered for the entire course. Early deviations were significantly correlated with total deviations (p<0.01). Using the criteria that a 10% increase in the final delivered dose indicates a replan may be needed earlier in the treatment course, the following guidelines can be made with a 90% specificity after the first 5 fractions: deviations of 7% in the mean dose to the inferior constrictors and 5% in the mean dose to the parotid glands and submandibular glands. No significant dose deviations were observed in any patients for the CTV -70Gy (max deviation 4%). Conclusions: A 5–7% increase in mean dose to normal tissues within the first 5 fractions strongly correlate to an overall deviatios in the delivered dose for HN patients. This work is funded in part by NIH 2P01CA059827-16.« less
Fang, Xin; Han, Hedong; Li, Mei; Liang, Chun; Fan, Zhongjie; Aaseth, Jan; He, Jia; Montgomery, Scott; Cao, Yang
2016-01-01
The epidemiological evidence for a dose-response relationship between magnesium intake and risk of type 2 diabetes mellitus (T2D) is sparse. The aim of the study was to summarize the evidence for the association of dietary magnesium intake with risk of T2D and evaluate the dose-response relationship. We conducted a systematic review and meta-analysis of prospective cohort studies that reported dietary magnesium intake and risk of incident T2D. We identified relevant studies by searching major scientific literature databases and grey literature resources from their inception to February 2016. We included cohort studies that provided risk ratios, i.e., relative risks (RRs), odds ratios (ORs) or hazard ratios (HRs), for T2D. Linear dose-response relationships were assessed using random-effects meta-regression. Potential nonlinear associations were evaluated using restricted cubic splines. A total of 25 studies met the eligibility criteria. These studies comprised 637,922 individuals including 26,828 with a T2D diagnosis. Compared with the lowest magnesium consumption group in the population, the risk of T2D was reduced by 17% across all the studies; 19% in women and 16% in men. A statistically significant linear dose-response relationship was found between incremental magnesium intake and T2D risk. After adjusting for age and body mass index, the risk of T2D incidence was reduced by 8%–13% for per 100 mg/day increment in dietary magnesium intake. There was no evidence to support a nonlinear dose-response relationship between dietary magnesium intake and T2D risk. The combined data supports a role for magnesium in reducing risk of T2D, with a statistically significant linear dose-response pattern within the reference dose range of dietary intake among Asian and US populations. The evidence from Europe and black people is limited and more prospective studies are needed for the two subgroups. PMID:27869762
Pearlman, David S; Eckerwall, Göran; McLaren, Julie; Lamarca, Rosa; Puu, Margareta; Gilbert, Ileen; Jorup, Carin; Sandin, Kristina; Lanz, Miguel J
2017-04-01
The efficacy and safety of budesonide/formoterol pressurized metered-dose inhaler (pMDI) have been demonstrated in patients with asthma at least 12 years old. To evaluate the efficacy of 2 formoterol doses added to budesonide as fixed combinations vs budesonide alone in children 6 to younger than 12 years with asthma. This randomized, double-blinded, parallel-group, multicenter study (NCT02091986; CHASE 3) included children 6 to younger than 12 years with asthma previously receiving a medium-dose inhaled corticosteroid (ICS) or an ICS plus a long-acting β 2 -agonist. Children symptomatic during a 7-28-day run-in on low-dose ICS, 1 inhalation of budesonide dry powder inhaler 90 μg twice daily (BID), were randomized to receive 2 inhalations of budesonide/formoterol pMDI 80/4.5 μg (160/9 μg) BID (n = 92), budesonide/formoterol pMDI 80/2.25 μg (160/4.5 μg) BID (n = 95), or budesonide pMDI 80 μg (160 μg) BID (n = 92) for 12 weeks. Change in forced expiratory volume in 1 second from baseline to 1 hour after dosing (primary end point), change in forced expiratory volume in 1 second 15 minutes after dosing, and peak expiratory flow 1 hour after dosing at week 12 were statistically significantly greater for budesonide/formoterol 160/9 μg vs budesonide (P ≤ .015 for all comparisons), but not for budesonide/formoterol 160/4.5 μg vs budesonide. Bronchodilator effects, evident 15 minutes after the dose on day 1, were maintained at week 12. Incidence of protocol-defined asthma exacerbations and improvements in asthma symptom-related and quality-of-life outcomes were similar across treatments. There were no notable safety differences among treatments. Budesonide/formoterol pMDI 160/9 μg showed statistically significant and clinically meaningful lung function improvements vs budesonide pMDI 160 μg, demonstrating appropriateness as a therapeutic option for children 6 to younger than 12 years with asthma symptomatic on ICS alone. ClinicalTrials.gov Identifier: NCT02091986. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Radwan, Ahmed Bassiuony; El-Debeiky, Mohammed Soliman; Abdel-Hay, Sameh
2015-08-01
Overflow retentive stool incontinence (ORSI) is secondary to constipation and fecal loading. In our study, the dose and duration of senna-based laxatives (SBL) treatment to achieve full defecatory control will be examined for possible correlation with new parameters measured from the initial contrast enema. Initially, an observational study was conducted prospectively on a group of patient with ORSI to define the optimum dose of SBL to achieve full defecatory control with measurement of six parameters in the initial contrast enema (level of colonic dilatation, recto-anal angle, ratio of maximal diameter of dilated colon to last lumbar spine, ratio of maximum diameter of dilated colon to normal descending colon, immediate and after 24-h post-evacuation residual contrast). The result was analyzed statistically to reach a correlation between the radiological data and prescribed dose. Over 2 and half years, 72 patients were included in the study; their mean age was 6.3 ± 3.33 years. The mean effective starting dose of SBL was 57 ± 18.13 mg/day and the mean effective ending dose was 75 ± 31.68 mg/day. Time lapsed till full defecatory control ranged from 1 to 16 weeks. Statistical correlation revealed that mean effective ending dose of SBL treatment significantly increased with higher levels of colonic dilatation. A weak positive correlation was found for both the mean effective starting and ending doses with the ratio of maximum colonic diameter to last lumbar spine and descending colonic diameters ratio. Senna-based laxatives are effective treatment for overflow retentive stool incontinence and their doses can be adjusted initially depending on the analysis of the radiological data.
Re-Irradiation of Hepatocellular Carcinoma: Clinical Applicability of Deformable Image Registration.
Lee, Dong Soo; Woo, Joong Yeol; Kim, Jun Won; Seong, Jinsil
2016-01-01
This study aimed to evaluate whether the deformable image registration (DIR) method is clinically applicable to the safe delivery of re-irradiation in hepatocellular carcinoma (HCC). Between August 2010 and March 2012, 12 eligible HCC patients received re-irradiation using helical tomotherapy. The median total prescribed radiation doses at first irradiation and re-irradiation were 50 Gy (range, 36-60 Gy) and 50 Gy (range, 36-58.42 Gy), respectively. Most re-irradiation therapies (11 of 12) were administered to previously irradiated or marginal areas. Dose summation results were reproduced using DIR by rigid and deformable registration methods, and doses of organs-at-risk (OARs) were evaluated. Treatment outcomes were also assessed. Thirty-six dose summation indices were obtained for three OARs (bowel, duodenum, and stomach doses in each patient). There was no statistical difference between the two different types of DIR methods (rigid and deformable) in terms of calculated summation ΣD (0.1 cc, 1 cc, 2 cc, and max) in each OAR. The median total mean remaining liver doses (M(RLD)) in rigid- and deformable-type registration were not statistically different for all cohorts (p=0.248), although a large difference in M(RLD) was observed when there was a significant difference in spatial liver volume change between radiation intervals. One duodenal ulcer perforation developed 20 months after re-irradiation. Although current dose summation algorithms and uncertainties do not warrant accurate dosimetric results, OARs-based DIR dose summation can be usefully utilized in the re-irradiation of HCC. Appropriate cohort selection, watchful interpretation, and selective use of DIR methods are crucial to enhance the radio-therapeutic ratio.
NASA Astrophysics Data System (ADS)
Malinovic-Milicevic, S.; Mihailovic, D. T.; Radovanovic, M. M.
2015-07-01
This paper focuses on the development and application of a technique for filling the daily erythemal UV dose data gaps and the reconstruction of the past daily erythemal UV doses in Novi Sad, Serbia. The technique implies developing the empirical equation for estimation of daily erythemal UV doses by means of relative daily sunshine duration under all sky conditions. A good agreement was found between modeled and measured values of erythemal UV doses. This technique was used for filling the short gaps in the erythemal UV dose measurement series (2003-2009) as well as for the reconstruction of the past time-series values (1981-2002). Statistically significant positive erythemal UV dose trend of 6.9 J m-2 per year was found during the period 1981-2009. In relation to the reference period 1981-1989, an increase in the erythemal UV dose of 6.92 % is visible in the period 1990-1999 and the increase of 9.67 % can be seen in the period 2000-2009. The strongest increase in erythemal UV doses has been found for winter and spring seasons.
Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu
2015-01-01
To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.
Euler, André; Solomon, Justin; Marin, Daniele; Nelson, Rendon C; Samei, Ehsan
2018-06-01
The purpose of this study was to assess image noise, spatial resolution, lesion detectability, and the dose reduction potential of a proprietary third-generation adaptive statistical iterative reconstruction (ASIR-V) technique. A phantom representing five different body sizes (12-37 cm) and a contrast-detail phantom containing lesions of five low-contrast levels (5-20 HU) and three sizes (2-6 mm) were deployed. Both phantoms were scanned on a 256-MDCT scanner at six different radiation doses (1.25-10 mGy). Images were reconstructed with filtered back projection (FBP), ASIR-V with 50% blending with FBP (ASIR-V 50%), and ASIR-V without blending (ASIR-V 100%). In the first phantom, noise properties were assessed by noise power spectrum analysis. Spatial resolution properties were measured by use of task transfer functions for objects of different contrasts. Noise magnitude, noise texture, and resolution were compared between the three groups. In the second phantom, low-contrast detectability was assessed by nine human readers independently for each condition. The dose reduction potential of ASIR-V was estimated on the basis of a generalized linear statistical regression model. On average, image noise was reduced 37.3% with ASIR-V 50% and 71.5% with ASIR-V 100% compared with FBP. ASIR-V shifted the noise power spectrum toward lower frequencies compared with FBP. The spatial resolution of ASIR-V was equivalent or slightly superior to that of FBP, except for the low-contrast object, which had lower resolution. Lesion detection significantly increased with both ASIR-V levels (p = 0.001), with an estimated radiation dose reduction potential of 15% ± 5% (SD) for ASIR-V 50% and 31% ± 9% for ASIR-V 100%. ASIR-V reduced image noise and improved lesion detection compared with FBP and had potential for radiation dose reduction while preserving low-contrast detectability.
NASA Astrophysics Data System (ADS)
Onac, I.; Pop, L.; Ungur, Rodica; Giurgiu, Ioana
2001-06-01
We checked the changes occurring in the metabolism of proteins (seric cholinesterase, total proteins) and in the metabolism of glycosides (seric glucose) in Cavia cobaia. A simple blind study was carried out and the results were checked on the first, tenth and twentieth days of treatment. The data thus obtained were graphically represented and statistically processed according to the Duncan test. The technique and treatment doses were similar and they were compared with the data obtained from controls and environment controls. In the groups biostimulated with He-Ne laser, seric cholinesterase levels increased proportionally with the dose reaching a peak on day 10, which was not the case with the controls. Monochromatic red light caused a similar but quantitatively lower effect. The same results were obtained in the case of seric proteins as well, however, the effect did not depend on the dose and it was less significant statistically than in the case of seric cholinesterase both in laser treated and in monochromatic red light treated groups.
Liu, Rong; Li, Xi; Zhang, Wei; Zhou, Hong-Hao
2015-01-01
Objective Multiple linear regression (MLR) and machine learning techniques in pharmacogenetic algorithm-based warfarin dosing have been reported. However, performances of these algorithms in racially diverse group have never been objectively evaluated and compared. In this literature-based study, we compared the performances of eight machine learning techniques with those of MLR in a large, racially-diverse cohort. Methods MLR, artificial neural network (ANN), regression tree (RT), multivariate adaptive regression splines (MARS), boosted regression tree (BRT), support vector regression (SVR), random forest regression (RFR), lasso regression (LAR) and Bayesian additive regression trees (BART) were applied in warfarin dose algorithms in a cohort from the International Warfarin Pharmacogenetics Consortium database. Covariates obtained by stepwise regression from 80% of randomly selected patients were used to develop algorithms. To compare the performances of these algorithms, the mean percentage of patients whose predicted dose fell within 20% of the actual dose (mean percentage within 20%) and the mean absolute error (MAE) were calculated in the remaining 20% of patients. The performances of these techniques in different races, as well as the dose ranges of therapeutic warfarin were compared. Robust results were obtained after 100 rounds of resampling. Results BART, MARS and SVR were statistically indistinguishable and significantly out performed all the other approaches in the whole cohort (MAE: 8.84–8.96 mg/week, mean percentage within 20%: 45.88%–46.35%). In the White population, MARS and BART showed higher mean percentage within 20% and lower mean MAE than those of MLR (all p values < 0.05). In the Asian population, SVR, BART, MARS and LAR performed the same as MLR. MLR and LAR optimally performed among the Black population. When patients were grouped in terms of warfarin dose range, all machine learning techniques except ANN and LAR showed significantly higher mean percentage within 20%, and lower MAE (all p values < 0.05) than MLR in the low- and high- dose ranges. Conclusion Overall, machine learning-based techniques, BART, MARS and SVR performed superior than MLR in warfarin pharmacogenetic dosing. Differences of algorithms’ performances exist among the races. Moreover, machine learning-based algorithms tended to perform better in the low- and high- dose ranges than MLR. PMID:26305568
Modeling the target dose fall-off in IMRT and VMAT planning techniques for cervical SBRT.
Brito Delgado, A; Cohen, D; Eng, T Y; Stanley, D N; Shi, Z; Charlton, M; Gutiérrez, A N
2018-01-01
There has been growing interest in the use of stereotactic body radiotherapy (SBRT) technique for the treatment of cervical cancer. The purpose of this study was to characterize dose distributions as well as model the target dose fall-off for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques using 6 and 10 MV photon beam energies. Fifteen (n = 15) patients with non-bulky cervical tumors were planned in Pinnacle 3 with a Varian Novalis Tx (HD120 MLC) using 6 and 10 MV photons with the following techniques: (1) IMRT with 10 non-coplanar beams (2) dual, coplanar 358° VMAT arcs (4° spacing), and (3) triple, non-coplanar VMAT arcs. Treatment volumes and dose prescriptions were segmented according to University of Texas Southwestern (UTSW) Phase II study. All plans were normalized such that 98% of the planning target volume (PTV) received 28 Gy (4 fractions). For the PTV, the following metrics were evaluated: homogeneity index, conformity index, D 2cc , D mean , D max , and dose fall-off parameters. For the organs at risk (OARs), D 2cc , D 15cc , D 0.01cc , V 20 , V 40 , V 50 , V 60 , and V 80 were evaluated for the bladder, bowel, femoral heads, rectum, and sigmoid. Statistical differences were evaluated using a Friedman test with a significance level of 0.05. To model dose fall-off, expanding 2-mm-thick concentric rings were created around the PTV, and doses were recorded. Statistically significant differences (p < 0.05) were noted in the dose fall-off when using 10 MV and VMAT 3-arc , as compared with IMRT. VMAT 3-arc improved the bladder V 40 , V 50 , and V 60 , and the bowel V 20 and V 50 . All fitted regressions had an R 2 ≥ 0.98. For cervical SBRT plans, a VMAT 3-arc approach offers a steeper dose fall-off outside of the target volume. Faster dose fall-off was observed in smaller targets as opposed to medium and large targets, denoting that OAR sparing is dependent on target size. These improvements are further pronounced with the use of 10-MV photons. Published by Elsevier Inc.
Pearson, Scott M; Trujillo, Jennifer M
2018-04-01
We wanted to determine whether basal insulin requirements change when patients transition from insulin glargine U-100 (Gla-100) to insulin glargine U-300 (Gla-300) or insulin degludec. This study involved subjects seen in the University of Colorado Health Endocrine Clinic who were transitioned from Gla-100 to either Gla-300 ( n = 95) or insulin degludec ( n = 39). The primary outcome was the difference between baseline Gla-100 dose and dose of Gla-300 or insulin degludec prescribed after first follow-up visit within 1-12 months. Secondary outcomes included changes in glycemic control and empiric dose conversion from Gla-100 to Gla-300 or insulin degludec on the day of transition. Wilcoxon rank sum tests evaluated changes in insulin doses, and paired t tests assessed changes in glycemic control using GraphPad statistical software. Median daily basal insulin dose increased for individuals transitioned from Gla-100 to Gla-300 from 30 [19-60 interquartile range (IQR)] units at baseline to 34.5 (19-70 IQR) units after follow up ( p = 0.01). For patients transitioned to insulin degludec, dose changes from baseline to follow up were not significantly different ( p = 0.56). At the time of transition, the prescribed dose of Gla-300 or insulin degludec did not significantly differ from the previous dose of Gla-100 ( p = 0.73 and 0.28, respectively), indicating that empiric dose adjustments were not routinely prescribed. Patients who transitioned from Gla-100 to Gla-300 had increased basal insulin requirements between visits, while basal insulin requirements for those transitioned from Gla-100 to insulin degludec were not significantly different.
Trujillo, Jennifer M.
2018-01-01
Background: We wanted to determine whether basal insulin requirements change when patients transition from insulin glargine U-100 (Gla-100) to insulin glargine U-300 (Gla-300) or insulin degludec. Methods: This study involved subjects seen in the University of Colorado Health Endocrine Clinic who were transitioned from Gla-100 to either Gla-300 (n = 95) or insulin degludec (n = 39). The primary outcome was the difference between baseline Gla-100 dose and dose of Gla-300 or insulin degludec prescribed after first follow-up visit within 1–12 months. Secondary outcomes included changes in glycemic control and empiric dose conversion from Gla-100 to Gla-300 or insulin degludec on the day of transition. Wilcoxon rank sum tests evaluated changes in insulin doses, and paired t tests assessed changes in glycemic control using GraphPad statistical software. Results: Median daily basal insulin dose increased for individuals transitioned from Gla-100 to Gla-300 from 30 [19–60 interquartile range (IQR)] units at baseline to 34.5 (19–70 IQR) units after follow up (p = 0.01). For patients transitioned to insulin degludec, dose changes from baseline to follow up were not significantly different (p = 0.56). At the time of transition, the prescribed dose of Gla-300 or insulin degludec did not significantly differ from the previous dose of Gla-100 (p = 0.73 and 0.28, respectively), indicating that empiric dose adjustments were not routinely prescribed. Conclusions: Patients who transitioned from Gla-100 to Gla-300 had increased basal insulin requirements between visits, while basal insulin requirements for those transitioned from Gla-100 to insulin degludec were not significantly different. PMID:29619208
Landes, Reid D.; Lensing, Shelly Y.; Kodell, Ralph L.; Hauer-Jensen, Martin
2014-01-01
The dose of a substance that causes death in P% of a population is called an LDP, where LD stands for lethal dose. In radiation research, a common LDP of interest is the radiation dose that kills 50% of the population by a specified time, i.e., lethal dose 50 or LD50. When comparing LD50 between two populations, relative potency is the parameter of interest. In radiation research, this is commonly known as the dose reduction factor (DRF). Unfortunately, statistical inference on dose reduction factor is seldom reported. We illustrate how to calculate confidence intervals for dose reduction factor, which may then be used for statistical inference. Further, most dose reduction factor experiments use hundreds, rather than tens of animals. Through better dosing strategies and the use of a recently available sample size formula, we also show how animal numbers may be reduced while maintaining high statistical power. The illustrations center on realistic examples comparing LD50 values between a radiation countermeasure group and a radiation-only control. We also provide easy-to-use spreadsheets for sample size calculations and confidence interval calculations, as well as SAS® and R code for the latter. PMID:24164553
Bradford, Ashley C; Bradford, W David; Abraham, Amanda; Bagwell Adams, Grace
2018-05-01
Opioid-related mortality increased by 15.6% from 2014 to 2015 and increased almost 320% between 2000 and 2015. Recent research finds that the use of all pain medications (opioid and nonopioid collectively) decreases in Medicare Part D and Medicaid populations when states approve medical cannabis laws (MCLs). The association between MCLs and opioid prescriptions is not well understood. To examine the association between prescribing patterns for opioids in Medicare Part D and the implementation of state MCLs. Longitudinal analysis of the daily doses of opioids filled in Medicare Part D for all opioids as a group and for categories of opioids by state and state-level MCLs from 2010 through 2015. Separate models were estimated first for whether the state had implemented any MCL and second for whether a state had implemented either a dispensary-based or a home cultivation only-based MCL. The primary outcome measure was the total number of daily opioid doses prescribed (in millions) in each US state for all opioids. The secondary analysis examined the association between MCLs separately by opioid class. From 2010 to 2015 there were 23.08 million daily doses of any opioid dispensed per year in the average state under Medicare Part D. Multiple regression analysis results found that patients filled fewer daily doses of any opioid in states with an MCL. The associations between MCLs and any opioid prescribing were statistically significant when we took the type of MCL into account: states with active dispensaries saw 3.742 million fewer daily doses filled (95% CI, -6.289 to -1.194); states with home cultivation only MCLs saw 1.792 million fewer filled daily doses (95% CI, -3.532 to -0.052). Results varied by type of opioid, with statistically significant estimated negative associations observed for hydrocodone and morphine. Hydrocodone use decreased by 2.320 million daily doses (or 17.4%) filled with dispensary-based MCLs (95% CI, -3.782 to -0.859; P = .002) and decreased by 1.256 million daily doses (or 9.4%) filled with home-cultivation-only-based MCLs (95% CI, -2.319 to -0.193; P = .02). Morphine use decreased by 0.361 million daily doses (or 20.7%) filled with dispensary-based MCLs (95% CI, -0.718 to -0.005; P = .047). Medical cannabis laws are associated with significant reductions in opioid prescribing in the Medicare Part D population. This finding was particularly strong in states that permit dispensaries, and for reductions in hydrocodone and morphine prescriptions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, A; Mohan, R; Liao, Z
Purpose: The aim of this work is to compare the “irradiated volume” (IRV) of normal tissues receiving 5, 20, 50, 80 and 90% or higher of the prescription dose with passively scattered proton therapy (PSPT) vs. IMRT of lung cancer patients. The overall goal of this research is to understand the factors affecting outcomes of a randomized PSPT vs. IMRT lung trial. Methods: Thirteen lung cancer patients, selected randomly, were analyzed. Each patient had PSPT and IMRT 74 Gy (RBE) plans meeting the same normal tissue constraints generated. IRVs were created for pairs of IMRT and PSPT plans on eachmore » patient. The volume of iGTV, (respiratory motion-incorporated GTV) was subtracted from each IRV to create normal tissue irradiated volume IRVNT. The average of IRVNT DVHs over all patients was also calculated for both modalities and inter-compared as were the selected dose-volume indices. Probability (p value) curves were calculated based on the Wilcoxon matched-paired signed-rank test to determine the dose regions where the statistically significant differences existed. Results: As expected, the average 5, 20 and 50% IRVNT’s for PSPT was found to be significantly smaller than for IMRT (p < 0.001, 0.01, and 0.001 respectively). However, the average 90% IRVNT for PSPT was greater than for IMRT (p = 0.003) presumably due to larger penumbra of protons and the long range of protons in lower density media. The 80% IRVNT for PSPT was also larger but not statistically distinguishable (p = .224). Conclusion: PSPT modality has smaller irradiated volume at lower doses, but larger volume at high doses. A larger cohort of lung patients will be analyzed in the future and IRVNT of patients treated with PSPT and IMRT will be compared to determine if the irradiated volumes (the magnitude of “dose bath”) correlate with outcomes.« less
The effect of single and repeated UVB radiation on rabbit cornea.
Fris, Miroslav; Tessem, May-Britt; Cejková, Jitka; Midelfart, Anna
2006-12-01
Cumulative effect of ultraviolet radiation (UVR) is an important aspect of UV corneal damage. The purpose of this study was to apply high resolution magic angle spinning proton nuclear magnetic resonance (HR-MAS 1H NMR) spectroscopy to evaluate the effect of single and repeated UV radiation exposure of the same overall dose on the rabbit cornea. Corneal surfaces of 24 normal rabbit eyes were examined for the effects of UVB exposure (312 nm). In the first group (UVB1), animals were irradiated with a single dose (3.12 J/cm2; 21 min) of UVB radiation. The animals in the second group (UVB2) were irradiated three times for 7 min every other day (dose of 1.04 J/cm2; days 1, 3, 5) to give the same overall dose (3.12 J/cm2). The third group served as an untreated control group. One day after the last irradiation, the animals were sacrificed, and the corneas were removed and frozen. HR-MAS 1H NMR spectra from intact corneas were obtained. Special grouping patterns among the tissue samples and the relative percentage changes in particular metabolite concentrations were evaluated using modern statistical methods (multivariate analysis, one-way ANOVA). The metabolic profile of both groups of UVB-irradiated samples was significantly different from the control corneas. Substantial decreases in taurine, hypo-taurine and choline-derivatives concentrations and substantial elevation in glucose and betaine levels were observed following the UVR exposure. There was no significant difference between the effect of a single and repeated UVB irradiation of the same overall dose. For the first time, the effects of single and repeated UVR doses on the metabolic profile of the rabbit cornea were analysed and compared. The combination of HR-MAS 1H NMR spectroscopy and modern statistical methods (multivariate analysis, one-way ANOVA) proved suitable to assess the overall view of the metabolic alterations in the rabbit corneal tissue following UVB radiation exposure.
Duration of treatment for asymptomatic bacteriuria during pregnancy.
Widmer, Mariana; Gülmezoglu, A Metin; Mignini, Luciano; Roganti, Ariel
2011-12-07
A Cochrane systematic review has shown that drug treatment of asymptomatic bacteriuria in pregnant women substantially decreases the risk of pyelonephritis and reduces the risk of preterm delivery. However, it is not clear whether single-dose therapy is as effective as longer conventional antibiotic treatment. To assess the effects of different durations of treatment for asymptomatic bacteriuria in pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 August 2011) and reference lists of identified articles. Randomized and quasi-randomized trials comparing antimicrobial therapeutic regimens that differed in duration (particularly comparing single dose with longer duration regimens) in pregnant women diagnosed with asymptomatic bacteriuria. We assessed trial quality and extracted data independently. We included 13 studies, involving 1622 women. All were comparisons of single-dose treatment with four- to seven-day treatments. The trials were generally of limited quality. The 'no cure rate' for asymptomatic bacteriuria in pregnant women was slightly higher for the single-dose than for the short-course treatment; however, these results were not statistically significant and showed heterogeneity. When comparing the trials that used the same antibiotic in both treatment and control groups with the trials that used different antibiotics in both groups, the 'no cure rate' risk ratio was similar. There was no statistically significant difference in the recurrence of asymptomatic bacteriuria rate between treatment and control groups. Slight differences were detected for preterm births and pyelonephritis although, apart from one trial, the sample size of the trials was inadequate. Single-dose treatment was associated with a decrease in reports of 'any side-effects' . Single-dose regimen of antibiotics may be less effective than the seven-day regimen. Women with asymptomatic bacteriuria in pregnancy should be treated by the standard regimen of antibiotics until more data become available testing seven-day compared with three- or five-day regimens.
Tumur, Odgerel; Soon, Kean; Brown, Fraser; Mykytowycz, Marcus
2013-06-01
The aims of our study were to evaluate the effect of application of Adaptive Statistical Iterative Reconstruction (ASIR) algorithm on the radiation dose of coronary computed tomography angiography (CCTA) and its effects on image quality of CCTA and to evaluate the effects of various patient and CT scanning factors on the radiation dose of CCTA. This was a retrospective study that included 347 consecutive patients who underwent CCTA at a tertiary university teaching hospital between 1 July 2009 and 20 September 2011. Analysis was performed comparing patient demographics, scan characteristics, radiation dose and image quality in two groups of patients in whom conventional Filtered Back Projection (FBP) or ASIR was used for image reconstruction. There were 238 patients in the FBP group and 109 patients in the ASIR group. There was no difference between the groups in the use of prospective gating, scan length or tube voltage. In ASIR group, significantly lower tube current was used compared with FBP group, 550 mA (450-600) vs. 650 mA (500-711.25) (median (interquartile range)), respectively, P < 0.001. There was 27% effective radiation dose reduction in the ASIR group compared with FBP group, 4.29 mSv (2.84-6.02) vs. 5.84 mSv (3.88-8.39) (median (interquartile range)), respectively, P < 0.001. Although ASIR was associated with increased image noise compared with FBP (39.93 ± 10.22 vs. 37.63 ± 18.79 (mean ± standard deviation), respectively, P < 0.001), it did not affect the signal intensity, signal-to-noise ratio, contrast-to-noise ratio or the diagnostic quality of CCTA. Application of ASIR reduces the radiation dose of CCTA without affecting the image quality. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Bai, W
Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) weremore » delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woods, K; Tran, A; Yu, V
Purpose: Thinning of the cerebral cortex has been observed in patients treated with fractionated partial brain radiation therapy and may contribute to cognitive decline following treatment. The extent of this thinning is dose-dependent, and was shown comparable to that of neurodegenerative diseases such as Alzheimer’s disease at one year post-therapy. This study investigates whether 4π radiotherapy can enable better sparing of the cortex and other critical structures when compared to conventional clinical IMRT plans. Methods: Clinical cortex-sparing IMRT plans for 15 high-grade glioma patients were included in this study. 4π radiotherapy plans were created for each patient with 20 intensity-modulatedmore » non-coplanar fields selected with a greedy column-generation optimization. All plans were normalized to deliver 100% of the prescribed dose to 95% of the planning target volume (PTV). The mean and maximum dose to the cerebral cortex and other organs at risk (OARs) were compared for the two plan types, as well as the conformity index (CI), homogeneity index (HI), and 50% dose spillage volume (R50). Results: The 4π plans significantly reduced the mean cortex dose by an average of 16% (range 6% to 27%) compared to the clinical plans. The mean dose to every other OAR compared was also reduced by 15% to 43%, with statistically significant reductions to the brainstem, chiasm, eyes, optic nerves, subcortical whit, and hippocampus. The average maximum doses were also reduced for 10/12 OARs. The R50 was significantly reduced with the 4π plans (>14%) and the homogeneity index was significantly improved. Conclusion: 4π enables significant sparing of the cerebral cortex when treating high-grade gliomas with fractionated partial brain radiation therapy, potentially reducing the risk of harmful dose-dependent cortical thinning. NIH R43CA183390, NIH R01CA188300, Varian Medical Systems.« less
40 CFR 158.34 - Flagging of studies for potential adverse effects.
Code of Federal Regulations, 2013 CFR
2013-07-01
... in malformations, pre- or post-natal deaths, or persistent functional or behavioral changes on a... statistically significant (pairwise p≤0.05) increase of any type of neoplasm in any test group, males or females... type of uncommon or rare neoplasms in any test group, males or females animals at any dose level...
40 CFR 158.34 - Flagging of studies for potential adverse effects.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in malformations, pre- or post-natal deaths, or persistent functional or behavioral changes on a... statistically significant (pairwise p≤ 0.05) increase of any type of neoplasm in any test group, males or... type of uncommon or rare neoplasms in any test group, males or females animals at any dose level...
40 CFR 158.34 - Flagging of studies for potential adverse effects.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in malformations, pre- or post-natal deaths, or persistent functional or behavioral changes on a... statistically significant (pairwise p≤ 0.05) increase of any type of neoplasm in any test group, males or... type of uncommon or rare neoplasms in any test group, males or females animals at any dose level...
40 CFR 158.34 - Flagging of studies for potential adverse effects.
Code of Federal Regulations, 2014 CFR
2014-07-01
... in malformations, pre- or post-natal deaths, or persistent functional or behavioral changes on a... statistically significant (pairwise p≤0.05) increase of any type of neoplasm in any test group, males or females... type of uncommon or rare neoplasms in any test group, males or females animals at any dose level...
40 CFR 158.34 - Flagging of studies for potential adverse effects.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in malformations, pre- or post-natal deaths, or persistent functional or behavioral changes on a... statistically significant (pairwise p≤0.05) increase of any type of neoplasm in any test group, males or females... type of uncommon or rare neoplasms in any test group, males or females animals at any dose level...
Lewis, Ryan C; Johns, Lauren E; Meeker, John D
2016-12-01
Human exposure to molybdenum (Mo) may play a role in reducing bone mineral density (BMD) by interfering with steroid sex hormone levels. To begin to address gaps in the literature on this topic, the potential relationship between urinary Mo (U-Mo) and BMD at the femoral neck (FN-BMD) and lumbar spine (LS-BMD) was explored in a sample of 1496 adults participating in the 2007-2010 cycles of the National Health and Nutrition Examination Survey. Associations were assessed using multiple linear regression models stratified on sex and age. In adjusted models for 50-80+ year-old women, there was a statistically significant inverse relationship between natural log-U-Mo and LS-BMD (p-value: 0.002), and a statistically significant dose-dependent decrease in LS-BMD with increasing U-Mo quartiles (trend p-value: 0.002). A suggestive (trend p-value: 0.08), dose-dependent decrease in FN-BMD with increasing U-Mo quartiles was noted in this group of women as well. All other adjusted models revealed no statistically significant or suggestive relationships between U-Mo and FN-BMD or LS-BMD. Bone health is important for overall human health and well-being and, given the exploratory nature of this work, additional studies are needed to confirm the results in other populations, and clarify the potential underlying mechanisms of Mo on BMD. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tilton, Susan C.; Markillie, Lye Meng; Hays, Spencer
Our goal here was to identify dose and temporal dependent radiation responses in a complex tissue, reconstituted human skin. Direct sequencing of RNA (RNA-seq) was used to quantify altered transcripts following exposure to 0.1, 2 and 10 Gy of ionizing radiation at 3 and 8 hours. These doses include a low dose in the range of some medical diagnostic procedures (0.1 Gy), a dose typically received during radiotherapy (2.0 Gy) and a lethal dose (10 Gy). These doses could be received after an intentional or accidental radiation exposure and biomarkers are needed to rapidly and accurately triage exposed individuals. Amore » total of 1701 genes were deemed to be significantly affected by high dose radiation exposure with the majority of genes affected at 10 Gy. A group of 29 genes including GDF15, BBC3, PPM1D, FDXR, GADD45A, MDM2, CDKN1A, TP53INP1, CYCSP27, SESN1, SESN2, PCNA, and AEN were similarly altered at both 2 and 10 Gy, but not 0.1 Gy, at multiple time points. A much larger group of up regulated genes, including those involved in inflammatory responses, was significantly altered only after a 10 Gy exposure. At high doses, down regulated genes were associated with cell cycle regulation and exhibited an apparent linear response between 2 and 10 Gy. While only a handful of genes were significantly affected by 0.1 Gy exposure using stringent statistical filters, groups of related genes regulating cell cycle progression and inflammatory responses consistently exhibited opposite trends in their regulation compared to the high dose exposures. Differential regulation of PLK1 signaling at low and high doses was confirmed using qRT-PCR. These results indicate that some alterations in gene expression are qualitatively different at low and high doses of radiation in this model system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ciura, Katherine; McBurney, Michelle; Nguyen, Baongoc
Intensity-modulated radiation therapy (IMRT) is becoming the treatment of choice for many head and neck cancer patients. IMRT reduces some toxicities by reducing radiation dose to uninvolved normal tissue near tumor targets; however, other tissues not irradiated using previous 3D techniques may receive clinically significant doses, causing undesirable side effects including nausea and vomiting (NV). Irradiation of the brainstem, and more specifically, the area postrema and dorsal vagal complex (DVC), has been linked to NV. We previously reported preliminary hypothesis-generating dose effects associated with NV in IMRT patients. The goal of this study is to relate brainstem dose to NVmore » symptoms. We retrospectively studied 100 consecutive patients that were treated for oropharyngeal cancer with IMRT. We contoured the brainstem, area postrema, and DVC with the assistance of an expert diagnostic neuroradiologist. We correlated dosimetry for the 3 areas contoured with weekly NV rates during IMRT. NV rates were significantly higher for patients who received concurrent chemotherapy. Post hoc analysis demonstrated that chemoradiation cases exhibited a trend towards the same dose-response relationship with both brainstem mean dose (p = 0.0025) and area postrema mean dose (p = 0.004); however, both failed to meet statistical significance at the p {<=} 0.002 level. Duration of toxicity was also greater for chemoradiation patients, who averaged 3.3 weeks with reported Common Terminology Criteria for Adverse Events (CTC-AE), compared with an average of 2 weeks for definitive RT patients (p = 0.002). For definitive RT cases, no dose-response trend could be ascertained. The mean brainstem dose emerged as a key parameter of interest; however, no one dose parameter (mean/median/EUD) best correlated with NV. This study does not address extraneous factors that would affect NV incidence, including the use of antiemetics, nor chemotherapy dose schedule specifics before and during RT. A prospective study will be required to depict exactly how IMRT dose affects NV.« less
Statistical analysis of radiation dose derived from ingestion of foods
NASA Astrophysics Data System (ADS)
Dougherty, Ward L.
2001-09-01
This analysis undertook the task of designing and implementing a methodology to determine an individual's probabilistic radiation dose from ingestion of foods utilizing Crystal Ball. A dietary intake model was determined by comparing previous existing models. Two principal radionuclides were considered-Lead210 (Pb-210) and Radium 226 (Ra-226). Samples from three different local grocery stores-Publix, Winn Dixie, and Albertsons-were counted on a gamma spectroscopy system with a GeLi detector. The same food samples were considered as those in the original FIPR database. A statistical analysis, utilizing the Crystal Ball program, was performed on the data to assess the most accurate distribution to use for these data. This allowed a determination of a radiation dose to an individual based on the above-information collected. Based on the analyses performed, radiation dose for grocery store samples was lower for Radium-226 than FIPR debris analyses, 2.7 vs. 5.91 mrem/yr. Lead-210 had a higher dose in the grocery store sample than the FIPR debris analyses, 21.4 vs. 518 mrem/yr. The output radiation dose was higher for all evaluations when an accurate estimation of distributions for each value was considered. Radium-226 radiation dose for FIPR and grocery rose to 9.56 and 4.38 mrem/yr. Radiation dose from ingestion of Pb-210 rose to 34.7 and 854 mrem/yr for FIPR and grocery data, respectively. Lead-210 was higher than initial doses for many reasons: Different peak examined, lower edge of detection limit, and minimum detectable concentration was considered. FIPR did not utilize grocery samples as a control because they calculated radiation dose that appeared unreasonably high. Consideration of distributions with the initial values allowed reevaluation of radiation does and showed a significant difference to original deterministic values. This work shows the value and importance of considering distributions to ensure that a person's radiation dose is accurately calculated. Probabilistic dose methodology was proved to be a more accurate and realistic method of radiation dose determination. This type of methodology provides a visual presentation of dose distribution that can be a vital aid in risk methodology.
Behavioral effects of microwaves: relationship of total dose and dose rate
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Connor, M.E.; Strattan, R.
1988-10-01
The goal of the research was to compare the relationship of whole-body averaged specific absorption rate (SAR) and specific absorption (SA) to determine whether dose rate or dose was the better predictor of biological effects. Sperm-positive Long-Evans female rats were exposed to 2450-MHz CW microwave radiation for 1-3 hours at approximately 10 W/kg. The maternal subjects were then observed for natural delivery of their litters. Sensitivity to thermally induced seizures and huddling were studied in the offspring. Analyses revealed that there were no statistically significant differences between exposed and control offspring on the behavioral indices. The behavior did not appearmore » to be affected by prenatal exposure to microwave radiation at this level. The huddle sizes became smaller as the pups aged both in exposed and control offspring.« less
Mutagenicity of diagnostic and therapeutical doses of radiopharmaceutical iodine-131 in Wistar rats.
Düsman, Elisângela; Berti, Alessandra Paim; Mariucci, Rosinete Gonçalves; Lopes, Nilson Benedito; Vicentini, Veronica Elisa Pimenta
2011-11-01
Iodine-131 ((131)I) is a radioisotope used for the diagnosis and treatment of thyroidal disorders such as hyperthyroidism and cancer. During its decay, (131)I emits beta particles and gamma rays; its physical half-life is 8 days, and it is accumulated preferentially in the thyroid tissue. This study aimed to evaluate the cytotoxicity and mutagenicity of diagnostic and therapeutic doses of (131)I using bone marrow cells of rats treated in vivo in a test system with a single dose by gavage. Concentrations of 5, 25, 50 and 250 μCi in 1 ml of water were used, and after 24 h, the animals were killed. Also, a concentration of 25 μCi/ml of water was used, and the animals were killed after 5 days. The results showed that no concentration of (131)I was cytotoxic and that all concentrations were mutagenic. As a result, there was no statistically significant difference detected by the χ(2) test in the induction of chromosomal aberrations between the different doses. Thus, the present study demonstrated a significant increase in chromosomal aberration in bone marrow cells exposed to (131)I regardless of the dose or the treatment time.
Nakamura, M; Ishii, A; Nakahara, D
1998-05-22
In vivo microdialysis was used to investigate the effect of beta-phenylethylamine on extracellular levels of monoamines and their metabolites in the nucleus accumbens of conscious rats. At all doses tested (1, 10 and 100 microM), infusion of beta-phenylethylamine through the microdialysis probe significantly increased extracellular levels of dopamine in the nucleus accumbens. These increases were dose-related. The increase in dopamine levels induced by 100 microM beta-phenylethylamine was not affected by co-perfusion of 4 microM tetrodotoxin. The ability of 100 microM beta-phenylethylamine to increase the extracellular level of dopamine was comparable to that of the same dose of methamphetamine. On the other hand, beta-phenylethylamine had a much less potent enhancing effect on 5-hydroxytryptamine (5-HT) than dopamine levels. Only the highest dose (100 microM) caused a statistically significant effect on 5-HT levels. Over the dose range tested (1, 10 and 100 microM), beta-phenylethylamine had no effect on extracellular metabolite levels of dopamine and 5-HT. The results suggest that beta-phenylethylamine increases the efflux of monoamines, preferentially dopamine, without affecting monoamine metabolism, in the nucleus accumbens.
Saito, Masazumi; Ueshima, Keiichiro; Fujioka, Mikihiro; Ishida, Masashi; Goto, Tsuyoshi; Arai, Yuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Fukushima, Wakaba; Kubo, Toshikazu
2014-06-01
It has been suggested that avascular osteonecrosis (AVN) of the femoral head occurs early after systemic steroid administration. The purpose of this study was to investigate the risks regarding development of AVN at a very early stage after renal transplantation. The presence or absence of AVN was determined by MRI at 4 weeks, at 6-12 weeks, at 24 weeks, and at 12 months after renal transplantation in 286 patients (183 males) with a mean age of 39 (16-65) years. The relationship between AVN and age, sex, absence or presence of acute rejection (AR), type of transplanted kidney (living or cadaveric), type of immune suppressor, and total dose of orally administered steroids given in the 2-week period after transplantation was investigated. There were no statistically significant correlations between the development of AVN and age, sex, absence or presence of AR, type of transplanted kidney, or type of immune suppressor. A significant dose-response relationship was found between development of AVN and the total dose of steroid administered in the first 2 weeks after surgery. We found a relationship between AVN development and steroid dose in the early postoperative period, and we also showed a dose-response relationship.
Dankers, Frank; Wijsman, Robin; Troost, Esther G C; Monshouwer, René; Bussink, Johan; Hoffmann, Aswin L
2017-05-07
In our previous work, a multivariable normal-tissue complication probability (NTCP) model for acute esophageal toxicity (AET) Grade ⩾2 after highly conformal (chemo-)radiotherapy for non-small cell lung cancer (NSCLC) was developed using multivariable logistic regression analysis incorporating clinical parameters and mean esophageal dose (MED). Since the esophagus is a tubular organ, spatial information of the esophageal wall dose distribution may be important in predicting AET. We investigated whether the incorporation of esophageal wall dose-surface data with spatial information improves the predictive power of our established NTCP model. For 149 NSCLC patients treated with highly conformal radiation therapy esophageal wall dose-surface histograms (DSHs) and polar dose-surface maps (DSMs) were generated. DSMs were used to generate new DSHs and dose-length-histograms that incorporate spatial information of the dose-surface distribution. From these histograms dose parameters were derived and univariate logistic regression analysis showed that they correlated significantly with AET. Following our previous work, new multivariable NTCP models were developed using the most significant dose histogram parameters based on univariate analysis (19 in total). However, the 19 new models incorporating esophageal wall dose-surface data with spatial information did not show improved predictive performance (area under the curve, AUC range 0.79-0.84) over the established multivariable NTCP model based on conventional dose-volume data (AUC = 0.84). For prediction of AET, based on the proposed multivariable statistical approach, spatial information of the esophageal wall dose distribution is of no added value and it is sufficient to only consider MED as a predictive dosimetric parameter.
NASA Astrophysics Data System (ADS)
Dankers, Frank; Wijsman, Robin; Troost, Esther G. C.; Monshouwer, René; Bussink, Johan; Hoffmann, Aswin L.
2017-05-01
In our previous work, a multivariable normal-tissue complication probability (NTCP) model for acute esophageal toxicity (AET) Grade ⩾2 after highly conformal (chemo-)radiotherapy for non-small cell lung cancer (NSCLC) was developed using multivariable logistic regression analysis incorporating clinical parameters and mean esophageal dose (MED). Since the esophagus is a tubular organ, spatial information of the esophageal wall dose distribution may be important in predicting AET. We investigated whether the incorporation of esophageal wall dose-surface data with spatial information improves the predictive power of our established NTCP model. For 149 NSCLC patients treated with highly conformal radiation therapy esophageal wall dose-surface histograms (DSHs) and polar dose-surface maps (DSMs) were generated. DSMs were used to generate new DSHs and dose-length-histograms that incorporate spatial information of the dose-surface distribution. From these histograms dose parameters were derived and univariate logistic regression analysis showed that they correlated significantly with AET. Following our previous work, new multivariable NTCP models were developed using the most significant dose histogram parameters based on univariate analysis (19 in total). However, the 19 new models incorporating esophageal wall dose-surface data with spatial information did not show improved predictive performance (area under the curve, AUC range 0.79-0.84) over the established multivariable NTCP model based on conventional dose-volume data (AUC = 0.84). For prediction of AET, based on the proposed multivariable statistical approach, spatial information of the esophageal wall dose distribution is of no added value and it is sufficient to only consider MED as a predictive dosimetric parameter.
Sertöz, Nezih; Aysel, İnan; Uyar, Meltem
2014-01-01
The aim of this study is to examine the effects of sufentanil added to low-dose hyperbaric bupivacaine in unilateral spinal anaesthesia for outpatients undergoing knee arthroscopy. Sixty two patients (ASA I-II) aged 20 to 50 who were planning on undergoing a knee arthroscopy were enrolled in this study. Patients were randomly divided into two groups. Unilateral spinal anaesthesia with 1ml 0.5% hyperbaric bupivacaine was administered to Group B (n=33); and unilateral spinal anaesthesia with 0.5ml (2.5µg) sufentanil added to 1ml hyperbaric bupivacaine was administered to Group BS (n=29). There were no statistically significant differences observed between the groups in terms of demographic data, hemodynamic parameters, maximum sensorial, sympathetic and motor block levels, time to motor block resolution, and time of discharge (p>0.05). There were statistically significant differences between the groups in terms of two segments regression time (Group B=52 min., Group BS=59 min.), ambulation time (Group B=147 min., Group BS=157 min.) and urination time (Group B=136 min., Group BS=149 min.) (p<0.05). In this study, no itching was observed in Group B, whereas seven patients in Group BS were observed as having postoperative itching (p<0.05). All patients were successfully given unilateral spinal anaesthesia with sufentanil added to low-dose hyperbaric bupivacaine for an outpatient knee arthroscopy, without affecting the time of discharge. However, for one-day interventions such as arthroscopy, it was concluded that administration of only low-dose hyperbaric bupivacaine was sufficient.
Mahapatra, Anita; Rajurkar, Sudhir; Eranezhath, Sujith; Manohar, Ram
2013-01-01
Purpose: To study the preventive and therapeutic Hypolipidemic effect of different coconut oil extracts of Vyosakatvivaradi formulation. Method: High fat diet was fed for 21 days to induce Hyperlipidemia. 110 weanling wistar rats randomly divided in to Eleven groups, four in treatment, four in preventive group, two control and one standarad group. Four test drugs – 1. VCO (virgin coconut oil) + HERBS, 2. TCO (Traditional coconut oil) + HERBS, 3. CCO (Commercial coconut oil) + HERBS, 4. TCO + Coconut Milk + HERBS were administered at the dose rate of 0.06ml tid orally for 28 days in treatment group and 28 days in preventive group from the day one of experiment and the results were compared with Simvastatin 10 mg. All the animals were anesthetized using anesthetic ether and pooled blood samples from each group were collected on day Zero, day 21st and on termination day i.e. day 28th after start of actual treatment. Result: Animals in all groups did not reveal any change in their behavior or visible adverse reaction throughout the experimental period. Statistically significant reduction in mean triglyceride values in test drug -4 animals revealed preventive. Statistically significant reduction in the mean cholesterol level (mg/dl) was observed in test drug -4 animals. Statistically significant increase in the mean HDL level 5% level of significance was observed in preventive dose of test drug 3. Microscopic observations of liver, kidney and aorta revealed no significant change. Conclusion: The medicated oil “CCO + HERBS” and TCO + Coconut Milk + HERBS” showed encouraging therapeutic and preventive effects on hyperlipidemia. However, the oil “TCO + Coconut Milk + HERBS” is observed to be better than the oil CCO + HERBS. Though the oils “VCO + HERBS” and “TCO + HERBS” exhibited moderate hypolipidemic action.
The Role of the Tamsulosin in the Medical Expulsion Therapy for Distal Ureteral Stones
Nuraj, Petrit; Hyseni, Nexhmi
2017-01-01
Background: This research aims to evaluate the role of tamsulosin in the medical expulsion therapy for distal ureteral stones, including her effects in stone expulsion time, expulsion rates, stone size, pain episodes and analgesic dosage usage. Material and methods: The 104 patients with distal ureteral calculi were examined, with the size of the stones 4-10 mm. They were randomly divided into two groups: study group (n=52), received tamsulosin 0.4 mg in morning, for 28 days, analgesic (diclofenac 75 mg), high fluid intake and Control group (n=52) received analgesic (diclofenac 75 mg), high fluid intake. Results: There is no significant difference between groups, based on sex (P=0.835) and age (P=0.987). Average size of the stones was 6.5 mm (SD ± 1.6 mm), with no significant difference (P=0.996). Stone expulsion rate is 90.4% in the study group and 71.2% from the control group, with statistical significance (P=0.023). The average time of the expulsion of stones in the study group was 9.6 days (SD ± 7.1 days), control group 13.7 days (SD ± 7.3 days), with statistical significance, (P=0.034). Average dose of analgesics in the study group was 63.7 mg (SD ± 45.2 mg), control group is 109.2 (SD ± 53.3), with statistical significance (P=0.019). Conclusion: Our study reveals that tamsulosin is efficient for the treatment of distal ureteral stones. Tamsulosin decrease the number of ureteral colic episodes, by acting as a spasmolytic, increase and hasten stone expulsion rates, reduce days of stone expulsion, decrease analgesic dose usage. PMID:28790547
Sethi, Rakesh; Naqash, Imtiaz A; Bajwa, Sukhminder Jit Singh; Dutta, Vikas; Ramzan, Altaf Umar; Zahoor, Syed Amir
2016-01-01
The glucocorticoid dexamethasone in a bolus dose of 8-10 mg followed by quarterly dose of 4 mg is commonly used during intracranial surgery so as to reduce oedema and vascular permeability. However, the detrimental hyperglycaemic effects of dexamethasone may override its potentially beneficial effects. The present prospective, randomised study aimed at comparing the degree and magnitude of hyperglycaemia induced by prophylactic administration of dexamethasone in patients undergoing elective craniotomy. Sixty American Society of Anaesthesiologist (ASA) grade-I and II patients were randomly assigned to three groups of 20 patients each. Group-I received dexamethasone during surgery for the first time. Group-II received dexamethasone in addition to receiving it pre-operatively, whereas Group-III (control group) patients were administered normal saline as placebo. Baseline blood glucose (BG) was measured in all the three groups before induction of anaesthesia and thereafter after every hour for 4 h and then two-hourly. Besides intra- and intergroup comparison of BG, peak BG concentration was also recorded for each patient. Statistical analysis was carried out with analysis of variance (ANOVA) and Student's t-test and value of P < 0.05 was considered statistically significant. Baseline BG reading were higher and statistically significant in Group-II as compared with Group-I and Group-III (P < 0.05). However, peak BG levels were significantly higher in Group-I than in Group-II and III (P < 0.05). Similarly, the magnitude of change in peak BG was significantly higher in Group-I as compared to Group-II and III (P < 0.05). Peri-operative administration of dexamethasone during neurosurgical procedures can cause significant increase in BG concentration especially in patients who receive dexamethasone intra-operatively only.
Sethi, Rakesh; Naqash, Imtiaz A.; Bajwa, Sukhminder Jit Singh; Dutta, Vikas; Ramzan, Altaf Umar; Zahoor, Syed Amir
2016-01-01
Background and Aim: The glucocorticoid dexamethasone in a bolus dose of 8-10 mg followed by quarterly dose of 4 mg is commonly used during intracranial surgery so as to reduce oedema and vascular permeability. However, the detrimental hyperglycaemic effects of dexamethasone may override its potentially beneficial effects. The present prospective, randomised study aimed at comparing the degree and magnitude of hyperglycaemia induced by prophylactic administration of dexamethasone in patients undergoing elective craniotomy. Materials and Methods: Sixty American Society of Anaesthesiologist (ASA) grade-I and II patients were randomly assigned to three groups of 20 patients each. Group-I received dexamethasone during surgery for the first time. Group-II received dexamethasone in addition to receiving it pre-operatively, whereas Group-III (control group) patients were administered normal saline as placebo. Baseline blood glucose (BG) was measured in all the three groups before induction of anaesthesia and thereafter after every hour for 4 h and then two-hourly. Besides intra- and intergroup comparison of BG, peak BG concentration was also recorded for each patient. Statistical analysis was carried out with analysis of variance (ANOVA) and Student's t-test and value of P < 0.05 was considered statistically significant. Results: Baseline BG reading were higher and statistically significant in Group-II as compared with Group-I and Group-III (P < 0.05). However, peak BG levels were significantly higher in Group-I than in Group-II and III (P < 0.05). Similarly, the magnitude of change in peak BG was significantly higher in Group-I as compared to Group-II and III (P < 0.05). Conclusion: Peri-operative administration of dexamethasone during neurosurgical procedures can cause significant increase in BG concentration especially in patients who receive dexamethasone intra-operatively only. PMID:27057213
Weinberg, Adriana; Huang, Sharon; Moscicki, Anna-Barbara; Saah, Afred; Levin, Myron J
2018-04-24
To determine the magnitude and persistence of quadrivalent human papillomavirus (HPV)16 and HPV18 B-cell and T-cell memory after three or four doses of quadrivalent HPV vaccine (QHPV) in HIV-infected children. Seventy-four HIV-infected children immunized with four doses and 23 with three doses of QHPV had HPV16 and HPV18 IgG B-cell and IFNγ and IL2 T-cell ELISPOT performed at 2, 3.5 and 4-5 years after the last dose. HPV16 and HPV18 T-cell responses were similar in both treatment groups, with higher responses to HPV16 vs. HPV18. These HPV T-cell responses correlated with HIV disease characteristics at the study visits. Global T-cell function declined over time as measured by nonspecific mitogenic stimulation. B-cell memory was similar across treatment groups and HPV genotypes. There was a decline in HPV-specific B-cell memory over time that reached statistical significance for HPV16 in the four-dose group. B-cell and T-cell memory did not significantly differ after either three or four doses of QHPV in HIV-infected children. The clinical consequences of decreasing global T-cell function and HPV B-cell memory over time in HIV-infected children requires further investigation.
Evans, Christy E; Getchell, Katerine E; Ivy, Delaney R
2018-04-01
Vitamin K antagonists (VKAs) have been used for decades to prevent thromboembolic events, but can be burdensome to patients based on numerous factors impacting anticoagulation control. Low-dose vitamin K supplementation has been theorized to improve anticoagulation control in patients on VKAs that may be vitamin K deficient. The objective of this literature review is to propose criteria for implementing low-dose vitamin K supplementation in patients on VKAs. The CHEST 2012 antithrombotic guidelines recommended against routine use of vitamin K supplementation in patients on VKAs. An observational study and three randomized controlled trials pertaining to this recommendation were evaluated. A literature review was also performed on other studies looking at the impact of low-dose vitamin K supplementation on anticoagulation control through a search in PubMed and the Cochrane Database of Systematic Reviews. One retrospective and two prospective studies were reviewed. Six of the seven studies demonstrated a non-statistically significant trend in data supporting improvement in anticoagulation control with low-dose vitamin K supplementation. While many of the studies did not achieve significant results, the majority demonstrated a trend in support of the improvement of anticoagulation control with low-dose vitamin K supplementation in patients on VKAs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyoizumi, Seishi; Akiyama, Mitoshi; Tanabe, Kazumi
To clarify the relationship between somatic cell mutations and radiation exposure, the frequency of hemizygous mutant erythrocytes at the glycophorin A (GPA) locus was measured by flow cytometry for 1,226 heterozygous atomic bomb (A-bomb) survivors in HIroshima and Nagasaki. For statistical analysis, both GPA mutant frequency and radiation dose were log-transformed to normalize skewed distributions of these variables. The GPA mutant frequency increased slightly but significantly with age at testing and with the number of cigarettes smoked. Also, mutant frequency was significantly higher in males than in females even with adjustment for smoking and was higher to Hiroshima than inmore » Nagasaki. These characteristics of background GPA mutant frequency are qualitatively similar to those of background solid cancer incidence or mortality obtained from previous epidemiological studies of survivors. An analysis of the mutant frequency dose response using a descriptive model showed that the doubling dose is about 1.20 Sv [95% confidence interval (CI): 0.95-1.56], whereas the minimum dose for detecting a significant increase in mutant frequency is about 0.24 Sv (95% CI: 0.041-0.51). No significant effects of sex, city or age at the time of exposure on the dose response were detected. Interestingly, the doubling dose of the GPA mutant frequency was similar to that of solid cancer incidence in A-bomb survivors. This observation is in line with the hypothesis that radiation-induced somatic cell mutations are the major cause of excess cancer risk after radiation. 49 refs., 6 figs., 2 tabs.« less
Quintana, D S; Westlye, L T; Hope, S; Nærland, T; Elvsåshagen, T; Dørum, E; Rustan, Ø; Valstad, M; Rezvaya, L; Lishaugen, H; Stensønes, E; Yaqub, S; Smerud, K T; Mahmoud, R A; Djupesland, P G; Andreassen, O A
2017-05-23
The neuropeptide oxytocin has shown promise as a treatment for symptoms of autism spectrum disorders (ASD). However, clinical research progress has been hampered by a poor understanding of oxytocin's dose-response and sub-optimal intranasal delivery methods. We examined two doses of oxytocin delivered using a novel Breath Powered intranasal delivery device designed to improve direct nose-to-brain activity in a double-blind, crossover, randomized, placebo-controlled trial. In a randomized sequence of single-dose sessions, 17 male adults with ASD received 8 international units (IU) oxytocin, 24IU oxytocin or placebo followed by four social-cognitive tasks. We observed an omnibus main effect of treatment on the primary outcome measure of overt emotion salience as measured by emotional ratings of faces (η 2 =0.18). Compared to placebo, 8IU treatment increased overt emotion salience (P=0.02, d=0.63). There was no statistically significant increase after 24IU treatment (P=0.12, d=0.4). The effects after 8IU oxytocin were observed despite no significant increase in peripheral blood plasma oxytocin concentrations. We found no significant effects for reading the mind in the eyes task performance or secondary outcome social-cognitive tasks (emotional dot probe and face-morphing). To our knowledge, this is the first trial to assess the dose-dependent effects of a single oxytocin administration in autism, with results indicating that a low dose of oxytocin can significantly modulate overt emotion salience despite minimal systemic exposure.
Gaus, Wilhelm
2014-09-02
The US National Toxicology Program (NTP) is assessed by a statistician. In the NTP-program groups of rodents are fed for a certain period of time with different doses of the substance that is being investigated. Then the animals are sacrificed and all organs are examined pathologically. Such an investigation facilitates many statistical tests. Technical Report TR 578 on Ginkgo biloba is used as an example. More than 4800 statistical tests are possible with the investigations performed. Due to a thought experiment we expect >240 false significant tests. In actuality, 209 significant pathological findings were reported. The readers of Toxicology Letters should carefully distinguish between confirmative and explorative statistics. A confirmative interpretation of a significant test rejects the null-hypothesis and delivers "statistical proof". It is only allowed if (i) a precise hypothesis was established independently from the data used for the test and (ii) the computed p-values are adjusted for multiple testing if more than one test was performed. Otherwise an explorative interpretation generates a hypothesis. We conclude that NTP-reports - including TR 578 on Ginkgo biloba - deliver explorative statistics, i.e. they generate hypotheses, but do not prove them. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Glass, Konsuela Y; Newsome, Cecilia R; Tchounwou, Paul B
2005-08-01
Dinitrotoluenes (DNTs) are byproducts of the explosive trinitrotoluene (TNT), and exist as a mixture of 2 to 6 isomers, with 2,4-DNT and 2,6-DNT being the most significant. The main route of human exposure at ammunition facilities is inhalation. The primary targets of DNTs toxicity are the hematopoietic system, cardiovascular system, nervous system and reproductive system. In factory workers, exposure to DNTs has been linked to many adverse health effects, including: cyanosis, vertigo, headache, metallic taste, dyspnea, weakness and lassitude, loss of appetite, nausea, and vomiting. Other symptoms including pain or parasthesia in extremities, abdominal discomfort, tremors, paralysis, chest pain, and unconsciousness have been documented. An association between DNTs exposure and increased risk of hepatocellular carcinomas and subcutaneous tumors in rats, as well as renal tumors in mice, has been established. This research was therefore designed targeting the liver to assess the cellular and molecular responses of human liver carcinoma cells following exposure to 2,4-DNT and 2,6-DNT. Cytotoxicity was evaluated using the MTT assay. Upon 48 hrs of exposure, LC50 values of 245 +/- 14.724 microg/mL, and 300 +/- 5.92 microg/mL were recorded for 2,6-DNT and 2,4-DNT respectively, indicating that both DNTs are moderately toxic, and 2,6-DNT is slightly more toxic to HepG2 cells than 2,4-DNT. A dose response relationship was recorded with respect to the cytotoxicity of both DNTs. Western blot analysis resulted in a significant expression (p<0.05) of the 70-kDa heat shock protein in 2,6-DNT-treated cells compared to the control cells and at the 200 microg/mL dose for 2,4-DNT. A statistically significant expression in c-fos was also observed at the 200 and 250 microg/mL treatment level for 2,4- and 2,6-DNT, respectively. However, no statistically significant expression of this protooncogene-related protein was observed at the doses of 0, 100, or 300 microg/mL or within the dose range of 0-200 microg/mL for 2,6-DNT. The 45-kDa growth arrest and damage protein was significantly expressed at the dose range of 200 - 250 microg/mL for 2,6-DNT and at the dose range of 200 - 400 microg/mL for 2,4-DNT. Expression of 153-kDa growth arrest and DNA damage protein was significant at the 100, 200, and 250 microg/mL doses for 2,6-DNT and at the 200 microg/mL dose for 2,4-DNT. Overall, these results indicate the potential of DNTs to induce cytotoxic, proteotoxic (HSP70), and genotoxic (GADD45/153) effects, as well as oxidative stress and pro-inflammatory reactions (c-fos).
Martin, Spencer; Chen, Jeff Z; Rashid Dar, A; Yartsev, Slav
2011-12-01
To compare radiotherapy treatment plans for mid- and distal-esophageal cancer with primary involvement of the gastroesophageal (GE) junction using a novel IMRT & Arc technique (IMRT & Arc), helical tomotherapy (HT), and RapidArc (RA1 and RA2). Eight patients treated on HT for locally advanced esophageal cancer with radical intent were re-planned for RA and IMRT&Arc. RA plans employed single and double arcs (RA1 and RA2, respectively), while IMRT&Arc plans had four fixed-gantry IMRT fields and a conformal arc. Dose-volume histogram statistics, dose uniformity, and dose homogeneity were analyzed to compare treatment plans. RA2 plans showed significant improvement over RA1 plans in terms of OAR dose and PTV dose uniformity and homogeneity. HT plan provided best dose uniformity (p=0.001) and dose homogeneity (p=0.002) to planning target volume (PTV), while IMRT&Arc and RA2 plans gave lowest dose to lungs among four radiotherapy techniques with acceptable PTV dose coverage. Mean V(10) of the lungs was significantly reduced by the RA2 plans compared to IMRT&Arc (40.3%, p=0.001) and HT (66.2%, p<0.001) techniques. Mean V(15) of the lungs for the RA2 plans also showed significant improvement over the IMRT&Arc (25.2%, p=0.042) and HT (34.8%, p=0.027) techniques. These improvements came at the cost of higher doses to the heart volume compared to HT and IMRT&Arc techniques. Mean lung dose (MLD) for the IMRT&Arc technique (21.2 ± 5.0% of prescription dose) was significantly reduced compared to HT (26.3%, p=0.004), RA1 (23.3%, p=0.028), and RA2 (23.2%, p=0.017) techniques. The IMRT&Arc technique is a good option for treating esophageal cancer with thoracic involvement. It achieved optimal low dose to the lungs and heart with acceptable PTV coverage. HT is a good option for treating esophageal cancer with little thoracic involvement as it achieves superior dose conformality and uniformity. The RA2 technique provided for improved treatment plans using additional arcs with low doses to the lungs at the cost of increased heart dose. Plan quality could still be improved through the use of additional arcs. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Dunner, David L.; Wohlreich, Madelaine M.; Mallinckrodt, Craig H.; Watkin, John G.; Fava, Maurizio
2005-01-01
Background: To reduce the risk for treatment-emergent adverse events and increase patient compliance, clinicians frequently prescribe a suboptimal starting dose of antidepressants, with the goal of increasing the dose once the patient has demonstrated tolerability. Objective: The aim of this study was to examine the tolerability and effectiveness associated with an initial week of duloxetine hydrochloride treatment at 30 mg QD and subsequent dose increase to 60 mg QD, compared with a starting dose of 60 mg QD. Methods: In this open-label study, all patients met the criteria for major depressive disorder (MDD) described in the American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision. Patients were required to wash out from previous antidepressant medications for 21 days, and were then randomized to receive duloxetine 30 or 60 mg QD for 1 week. After 1 week, patients receiving duloxetine 30 mg QD had their dose increased to 60 mg QD. Patients returned for assessments at weeks 2, 4, 6, 8, and 12. During the remainder of the 12-week study period, the duloxetine dose could be titrated based on the degree of response from 60 mg QD (minimum) to 120 mg QD (maximum), with 90 mg QD as an intermediate dose. Tolerability was assessed by means of discontinuation rates, spontaneously reported adverse events, changes in vital signs, and laboratory tests. Effectiveness measures included the 17-item Hamilton Rating Scale for Depression (HAMD17) total score, HAMD17 core and Maier subscales, individual HAMD17 items, the Hamilton Rating Scale for Anxiety total score, and the Clinical Global Impression of Severity. Results: One hundred thirty-seven patients were enrolled (82 women, 55 men; mean age, 42 years; duloxetine 30 mg QD, 67 patients; duloxetine 60 mg QD, 70 patients). The rate of discontinuation due to adverse events did not differ significantly between patients starting duloxetine at 30 mg QD and 60 mg QD (13.4% vs 18.6%). The most frequently reported adverse events across both treatment groups were nausea, headache, dry mouth, insomnia, and diarrhea. In the first week of treatment, patients receiving duloxetine 30 mg QD had a significantly lower rate of nausea compared with patients receiving 60 mg QD (16.4% vs 32.9%; P = 0.03). Over the 12-week acute-treatment phase, patients starting duloxetine treatment at 30 mg QD had a significantly lower rate of nausea compared with patients initiating treatment at 60 mg QD (P = 0.047). Although between-group differences in the HAMD17 total score were not statistically significant at any visit, patients starting at 30 mg QD experienced significantly less improvement in HAMD17 core and Maier subscales at week 1 compared with patients starting at 60 mg QD (core, P= 0.044; Maier, P = 0.047). After 2 weeks of treatment, the magnitude of improvement among patients starting at 30 mg QD did not differ significantly from that observed in patients who started treatment at 60 mg QD, and there were no significant between-group differences in effectiveness at any subsequent visit. Conclusions: Results from this open-label study in patients with MDD suggest that starting duloxetine treatment at 30 mg QD for 1 week, followed by escalation to 60 mg QD, might reduce the risk for treatment-emergent nausea in these patients while producing only a transitory impact on effectiveness compared with a starting dose of 60 mg QD. PMID:24678074
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, S; Zhu, X; Zhang, M
Purpose: Randomness in patient internal organ motion phase at the beginning of non-gated radiotherapy delivery may introduce uncertainty to dose received by the patient. Concerns of this dose deviation from the planned one has motivated many researchers to study this phenomenon although unified theoretical framework for computing it is still missing. This study was conducted to develop such framework for analyzing the effect. Methods: Two reasonable assumptions were made: a) patient internal organ motion is stationary and periodic; b) no special arrangement is made to start a non -gated radiotherapy delivery at any specific phase of patient internal organ motion.more » A statistical ensemble was formed consisting of patient’s non-gated radiotherapy deliveries at all equally possible initial organ motion phases. To characterize the patient received dose, statistical ensemble average method is employed to derive formulae for two variables: expected value and variance of dose received by a patient internal point from a non-gated radiotherapy delivery. Fourier Series was utilized to facilitate our analysis. Results: According to our formulae, the two variables can be computed from non-gated radiotherapy generated dose rate time sequences at the point’s corresponding locations on fixed phase 3D CT images sampled evenly in time over one patient internal organ motion period. The expected value of point dose is simply the average of the doses to the point’s corresponding locations on the fixed phase CT images. The variance can be determined by time integration in terms of Fourier Series coefficients of the dose rate time sequences on the same fixed phase 3D CT images. Conclusion: Given a non-gated radiotherapy delivery plan and patient’s 4D CT study, our novel approach can predict the expected value and variance of patient radiation dose. We expect it to play a significant role in determining both quality and robustness of patient non-gated radiotherapy plan.« less
Glyphosate rodent carcinogenicity bioassay expert panel review.
Williams, Gary M; Berry, Colin; Burns, Michele; de Camargo, Joao Lauro Viana; Greim, Helmut
2016-09-01
Glyphosate has been rigorously and extensively tested for carcinogenicity by administration to mice (five studies) and to rats (nine studies). Most authorities have concluded that the evidence does not indicate a cancer risk to humans. The International Agency for Research on Cancer (IARC), however, evaluated some of the available data and concluded that glyphosate probably is carcinogenic to humans. The expert panel convened by Intertek assessed the findings used by IARC, as well as the full body of evidence and found the following: (1) the renal neoplastic effects in males of one mouse study are not associated with glyphosate exposure, because they lack statistical significance, strength, consistency, specificity, lack a dose-response pattern, plausibility, and coherence; (2) the strength of association of liver hemangiosarcomas in a different mouse study is absent, lacking consistency, and a dose-response effect and having in high dose males only a significant incidence increase which is within the historical control range; (3) pancreatic islet-cell adenomas (non-significant incidence increase), in two studies of male SD rats did not progress to carcinomas and lacked a dose-response pattern (the highest incidence is in the low dose followed by the high dose); (4) in one of two studies, a non-significant positive trend in the incidence of hepatocellular adenomas in male rats did not lead to progression to carcinomas; (5) in one of two studies, the non-significant positive trend in the incidence of thyroid C-cell adenomas in female rats was not present and there was no progression of adenomas to carcinomas at the end of the study. Application of criteria for causality considerations to the above mentioned tumor types and given the overall weight-of-evidence (WoE), the expert panel concluded that glyphosate is not a carcinogen in laboratory animals.
Lee, Myeung Su; Ahn, Seon Ho; Song, Ju Hung
2002-01-01
Background: Recombinant human erythropoietin (epoetin) has greatly contributed to improvement of the anemia of chronic renal failure patients on hemodialysis. However, the reduced erythropoietic effect to epoetin and its high cost have induced lots of supplementary treatments. Therefore, we performed a prospective study to evaluate the effects of adjuvant low-dose androgen therapy in patients using a lower-dose of epoetin than the commonly recommended dose on anemia and the nutritional parameters. Methods : 17 patients of hemoglobin (Hgb) less than 9 g/dL even after being treated with 1,000 U epoetin subcutaneously (s.c.) 3 times per week on a stable status for more than 6 months, who were on hemodialysis at our institution were examined. They were injected with the same dose of epoetin s.c. and nandrolone decanoate 100 mg intramuscularly (i.m) weekly for another 6 months. Blood test was performed every month before therapy for 6 months and after therapy for 6 months and the mean values were reviewed for comparison. Results: Hgb (7.75±0.9 vs 8.99±1.39 g/dL, p <0.01) and hematocrit (Hct) (23.68±2.85 vs 26.66±3.91%, p <0.01) were apparently changed before and after adjuvant therapy. Hgb and Hct, weekly dose of epoetin were not statistically different in 9 male patients before and after adjuvant therapy. The weekly dose of epoetin was not statistically different in 8 female patients, but Hgb and Hct (8.02±0.6 vs 9.72±1.31 g/dL, 24.54±1.7 vs 28.74±3.06%, p <0.01) were statistically different before and after adjuvant therapy. In comparison between male and female groups, weekly doses of epoetin and nandrolone decanoate were significantly greater in the female group than the male group (epoetin: 50.66±6.23 vs 61.18±8.76 U/kg/week, nandrolone decanoate: 1.69±0.2 vs 2.04±0.29 mg/kg/week, p <0.05). Conclusion : Our data show that the adjuvant androgen therapy is effective for the anemia of hemodialysis patients who did not recover from anemia even after being continuously treated with low-dose epoetin. PMID:12298427
Ahmed, Irfan; DeMarco, Marylou; Stevens, Craig W; Fulp, William J; Dilling, Thomas J
2011-01-01
Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI(off)) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI(on)). Nodal stations were contoured using published guidelines, then placed into 4 "bins" (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI(on) plans demonstrated a statistically significant degradation in dose coverage compared with the ENI(off) plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the "1 echelon away" nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes within the mediastinum. The ENI(on) plans demonstrate that intergroup-style treatments, as actually delivered, had statistically reduced coverage to the mediastinum and tumor volumes than was reported. Furthermore, SNI leads to improved tumor coverage and reduced esophageal/spinal cord dose, which suggests the possibility of dose escalation using SNI. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, D; Chi, Z; Yang, H
Purpose: To investigate the performances of three commercial treatment planning systems (TPS) for intensity modulated radiotherapy (IMRT) optimization regarding cervical cancer. Methods: For twenty cervical cancer patients, three IMRT plans were retrospectively re-planned: one with Pinnacle TPS,one with Oncentra TPS and on with Eclipse TPS. The total prescribed dose was 50.4 Gy delivered for PTV and 58.8 Gy for PTVnd by simultaneous integrated boost technique. The treatments were delivered using the Varian 23EX accelerator. All optimization schemes generated clinically acceptable plans. They were evaluated based on target coverage, homogeneity (HI) and conformity (CI). The organs at risk (OARs) were analyzedmore » according to the percent volume under some doses and the maximum doses. The statistical method of the collected data of variance analysis was used to compare the difference among the quality of plans. Results: IMRT with Eclipse provided significant better HI, CI and all the parameters of PTV. However, the trend was not extension to the PTVnd, it was still significant better at mean dose, D50% and D98%, but plans with Oncentra showed significant better in the hight dosage volume, such as maximum dose and D2%. For the bladder wall, there were not notable difference among three groups, although Pinnacle and Oncentra systems provided a little lower dose sparing at V50Gy of bladder and rectal wall and V40Gy of bladder wall, respectively. V40Gy of rectal wall (p=0.037), small intestine (p=0.001 for V30Gy, p=0.010 for maximum dose) and V50Gy of right-femoral head (p=0.019) from Eclipse plans showed significant better than other groups. Conclusion: All SIB-IMRT plans were clinically acceptable which were generated by three commercial TPSs. The plans with Eclipse system showed advantages over the plans with Oncentra and Pinnacle system in the overwhelming majority of the dose coverage for targets and dose sparing of OARs in cervical cancer.« less
Little, Mark P; Kwon, Deukwoo; Zablotska, Lydia B; Brenner, Alina V; Cahoon, Elizabeth K; Rozhko, Alexander V; Polyanskaya, Olga N; Minenko, Victor F; Golovanov, Ivan; Bouville, André; Drozdovitch, Vladimir
2015-01-01
The excess incidence of thyroid cancer in Ukraine and Belarus observed a few years after the Chernobyl accident is considered to be largely the result of 131I released from the reactor. Although the Belarus thyroid cancer prevalence data has been previously analyzed, no account was taken of dose measurement error. We examined dose-response patterns in a thyroid screening prevalence cohort of 11,732 persons aged under 18 at the time of the accident, diagnosed during 1996-2004, who had direct thyroid 131I activity measurement, and were resident in the most radio-actively contaminated regions of Belarus. Three methods of dose-error correction (regression calibration, Monte Carlo maximum likelihood, Bayesian Markov Chain Monte Carlo) were applied. There was a statistically significant (p<0.001) increasing dose-response for prevalent thyroid cancer, irrespective of regression-adjustment method used. Without adjustment for dose errors the excess odds ratio was 1.51 Gy- (95% CI 0.53, 3.86), which was reduced by 13% when regression-calibration adjustment was used, 1.31 Gy- (95% CI 0.47, 3.31). A Monte Carlo maximum likelihood method yielded an excess odds ratio of 1.48 Gy- (95% CI 0.53, 3.87), about 2% lower than the unadjusted analysis. The Bayesian method yielded a maximum posterior excess odds ratio of 1.16 Gy- (95% BCI 0.20, 4.32), 23% lower than the unadjusted analysis. There were borderline significant (p = 0.053-0.078) indications of downward curvature in the dose response, depending on the adjustment methods used. There were also borderline significant (p = 0.102) modifying effects of gender on the radiation dose trend, but no significant modifying effects of age at time of accident, or age at screening as modifiers of dose response (p>0.2). In summary, the relatively small contribution of unshared classical dose error in the current study results in comparatively modest effects on the regression parameters.
Narayanasamy, Ganesh; Avila, Gabrielle; Mavroidis, Panayiotis; Papanikolaou, Niko; Gutierrez, Alonso; Baacke, Diana; Shi, Zheng; Stathakis, Sotirios
2016-09-01
Prostate cases commonly consist of dual phase planning with a primary plan followed by a boost. Traditionally, the boost phase is planned independently from the primary plan with the risk of generating hot or cold spots in the composite plan. Alternatively, boost phase can be planned taking into account the primary dose. The aim of this study was to compare the composite plans from independently and dependently planned boosts using dosimetric and radiobiological metrics. Ten consecutive prostate patients previously treated at our institution were used to conduct this study on the Raystation™ 4.0 treatment planning system. For each patient, two composite plans were developed: a primary plan with an independently planned boost and a primary plan with a dependently planned boost phase. The primary plan was prescribed to 54 Gy in 30 fractions to the primary planning target volume (PTV1) which includes prostate and seminal vesicles, while the boost phases were prescribed to 24 Gy in 12 fractions to the boost planning target volume (PTV2) that targets only the prostate. PTV coverage, max dose, median dose, target conformity, dose homogeneity, dose to OARs, and probabilities of benefit, injury, and complication-free tumor control (P+) were compared. Statistical significance was tested using either a 2-tailed Student's t-test or Wilcoxon signed-rank test. Dosimetrically, the composite plan with dependent boost phase exhibited smaller hotspots, lower maximum dose to the target without any significant change to normal tissue dose. Radiobiologically, for all but one patient, the percent difference in the P+ values between the two methods was not significant. A large percent difference in P+ value could be attributed to an inferior primary plan. The benefits of considering the dose in primary plan while planning the boost is not significant unless a poor primary plan was achieved.
Roaiah, Mohamed Farid; El Khayat, Yasser Ibrahim; GamalEl Din, Sameh Fayek; Abd El Salam, Mohamed Ahmed
2016-05-18
This study was conducted on 30 consecutive male patients presenting to Kasr-Al Ainy Andrology outpatient clinic complaining of manifestations of partial androgen deficiency in aging males (PADAM). In this study (750 mg/day) of Tribulus terrestris in 3 divided doses, each of 250 mg, as an endogenous testosterone enhancer had been tried for a duration of 3 months and the evaluation of its effect had been monitored for each patient concerning its effect on serum testosterone (total and free) and luteinizing hormone (LH), as well as its impact on erectile function, which was evaluated by the International Index of Erectile Function-5 (IIEF-5) questionnaire for those patients. Results showed a statistically significant difference in the level of testosterone (total and free) and IIEF-5, but no statistically significant difference in the level of LH before and after treatment. Also, the study showed statistically significant correlation between testosterone (total and free) and IIEF-5, but no statistically significant correlation between the level of LH and the IIEF-5 before and after treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kole, Thomas P.; Aghayere, Osarhieme; Kwah, Jason
Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters weremore » statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D-CRT. Long-term studies are necessary to determine how this will impact on development of coronary artery disease and other cardiac complications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guthier, C; University Medical Center Mannheim, Mannheim; Harvard Medical School, Boston, MA
Purpose: Inverse treatment planning (ITP) for interstitial HDR brachytherapy of gynecologic cancers seeks to maximize coverage of the clinical target volumes (tumor and vagina) while respecting dose-volume-histogram related dosimetric measures (DMs) for organs at risk (OARs). Commercially available ITP tools do not support DM-based planning because it is computationally too expensive to solve. In this study we present a novel approach that allows fast ITP for gynecologic cancers based on DMs for the first time. Methods: This novel strategy is an optimization model based on a smooth DM-based objective function. The smooth approximation is achieved by utilizing a logistic functionmore » for the evaluation of DMs. The resulting nonconvex and constrained optimization problem is then optimized with a BFGS algorithm. The model was evaluated using the implant geometry extracted from 20 patient treatment plans under an IRB-approved retrospective study. For each plan, the final DMs were evaluated and compared to the original clinical plans. The CTVs were the contoured tumor volume and the contoured surface of the vagina. Statistical significance was evaluated with a one-sided paired Wilcoxon signed-rank test. Results: As did the clinical plans, all generated plans fulfilled the defined DMs for OARs. The proposed strategy showed a statistically significant improvement (p<0.001) in coverage of the tumor and vagina, with absolute improvements of related DMs of (6.9 +/− 7.9)% and (28.2 +/− 12.0)%, respectively. This was achieved with a statistically significant (p<0.01) decrease of the high-dose-related DM for the tumor. The runtime of the optimization was (2.3 +/− 2.0) seconds. Conclusion: We demonstrated using clinical data that our novel approach allows rapid DM-based optimization with improved coverage of CTVs with fewer hot spots. Being up to three orders of magnitude faster than the current clinical practice, the method dramatically shortens planning time.« less
Ince Gunal, D; Agan, K; Afsar, N; Borucu, D; Us, O
2008-04-01
Autosomal dominant cerebellar ataxias are clinically and genetically heterogeneous neurodegenerative disorders. There is no known treatment to prevent neuronal cell death in these disorders. Current treatment is purely symptomatic; ataxia is one of the most disabling symptoms and represents the main therapeutic challenge. A previous case report suggesting benefit from administration of high dose piracetam inspired the present study of the efficacy of this agent in patients with cerebellar ataxia. Piracetam is a low molecular weight derivative of gamma-aminobutyric acid. Although little is known of its mode of action, its efficacy has been documented in a wide range of clinical indications, such as cognitive disorders, dementia, vertigo and dyslexia, as well as cortical myoclonus. The present report investigated the role of high dose piracetam in patients with cerebellar ataxia. Eight patients with autosomal dominant cerebellar ataxia were given intravenous piracetam 60 g/day by a structured protocol for 14 days. The baseline and end-of-the study evaluations were based on the International Cooperative Ataxia Rating Scale. Statistical analysis demonstrated a significant improvement in the patients' total score (P = 0.018) and a subscale analysis showed statistical significance for only the posture and gait disturbances item (P = 0.018). This study is providing good clinical observation in favour of high dose piracetam infusion to reduce the disability of the patients by improving their gait ataxia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it; Kuthpady, Shrinivas; Anderson, Anne
To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results.more » Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.« less
Wang, Li-hong; Wang, Xu; Yu, Xi-zhong; Xu, Wen-ting
2016-02-01
To investigate the effect of Shouwu Jiangqi Decoction (SJD) on polycystic ovary syndrome (PCOS) with insulin resistance (IR) in rats and to explore the underlining molecular mechanisms. A total of 51 female Sprague-Dawley rats were randomly divided into 6 groups: control group (n=7), model group (n=8), SJD high-dose group (n=9), SJD medium-dose group (n=9), SJD low-dose group (n=9) and DMBG group (n=9). Radioimmunoassay was used to measure serum follicle-stimulating hormone (FSH), luteinizing hormone (LH) and testosterone concentrations and qRT-PCR and western blot were used to examine the expression levels of mRNA and protein respectively of insulin receptor substrate 1 (IRS-1) and phosphatidylinositide 3-kinases (PI3K) p85α in different groups. FSH level significantly decreased in the model group compared with the normal control (P<0.01), and high-dose SJD and DMBG can significantly increase FSH level (P<0.01). LH level showed a mild increase without statistic significance in the model group compared with the control and different dosages of SJD had no significance effect on LH level, while DMBG can significantly decrease LH level (P<0.01). Testosterone level significantly increased in the model group compared with the control group (P<0.01), and high-dose SJD and DMBG can significantly decrease testosterone level (P<0.01). The expression of IRS-1 as well as PI3Kp85α were significantly decreased in the model group compared with the normal control group at both mRNA (P<0.001) and protein (P<0.01) level, and both high-dose SJD and DMBG can enhance IRS-1 and PI3K expression (P<0.05). SJD has potent therapeutic effects on PCOS with IR in rats. The therapeutic effects of SJD on IR and ovulatory dysfunction are probably achieved through correcting the defective insulin signaling transduction.
Vitamin C modulates lead excretion in rats.
Lihm, Hoseob; Kim, Hyun; Chang, Heekyung; Yoon, Myunghee; Lee, Kayoung; Choi, Jongsoon
2013-12-01
Lead, one of the most toxic heavy metals, takes longer time to be excreted from the body than other heavy metals. The purpose of this study is, by measuring lead excretion via urine and feces, to find out the effect of vitamin C in lead chelation. Thirty-six rats were randomly assorted into four groups. All 33 rats except for the control group were administered with lead, before orally administered with different doses of vitamin C per kilogram of body weight. The lead excretion levels in urine and feces as well as the survival rate were then measured for each group. The rats with lead administrations (10/13, 76.9%) with lead administrations only, 10/11 rats (90.9%) with lead administrations and low dose of vitamin C, 9/9 rats (100%) with lead administrations and high dose of vitamin C survived. Among the 29 surviving rats, low vitamin C intake group exhibited higher urinary excretion than the lead only group. The urinary excretion level in high dose vitamin C intakegroup was significantly higher than the lead only group. In addition, fecal lead excretion seemed to be increased in the high dose vitamin C intake group, compared to the group with lead administrations only with statistical significance. Through animal experiment, it was found out that administrating high dose of vitamin C accelerated the excretion of lead in body compared to low dose of vitamin C.
Niglas, Mark; McCann, Claire; Keller, Brian M; Makhani, Nadiya; Presutti, Joseph; Vesprini, Danny; Rakovitch, Eileen; Elzibak, Alyaa; Mashouf, Shahram; Lee, Justin
2016-01-01
Breath-hold techniques can reduce cardiac dose in breast radiotherapy. The reverse semi-decubitus (RSD) technique is an alternative free-breathing method used at our centre. This study compares the dosimetry of free-breathing supine, RSD and moderate deep inspiration breath-hold (mDIBH) techniques. Twelve patients with left-sided breast cancer who were simulated using standard supine, RSD and mDIBH techniques were identified retrospectively. New plans using standard breast tangents and techniques for internal mammary chain (IMC) nodal coverage were assessed. Using standard tangents, mean heart dose, heart V25Gy and mean left anterior descending artery (LAD) dose were found to be significantly lower for RSD and mDIBH when compared to free-breathing supine (p ⩽ 0.03). Using wide-tangents, the maximum LAD point dose was also lower for RSD and mDIBH (p ⩽ 0.02). There were no statistically significant dosimetric differences found between the RSD and mDIBH simulation techniques for standard breast-tangent plans, though organ-at-risk doses were lower for mDIBH in wide-tangent plans. There was no improvement in cardiac dosimetry between RSD and free-breathing supine when using an electron field IMC plan. For patients unable to tolerate breath-hold, the RSD technique is an alternative approach that can reduce cardiac dose. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Qu, Shu-Gen; Gao, Jin; Tang, Bo; Yu, Bo; Shen, Yue-Ping; Tu, Yu
2018-01-01
Low-dose ionizing radiation (LDIR) may increase the mortality of solid cancers in nuclear industry workers, but only few individual cohort studies exist, and the available reports have low statistical power. The aim of the present study was to focus on solid cancer mortality risk from LDIR in the nuclear industry using standard mortality ratios (SMRs) and 95% confidence intervals. A systematic literature search through the PubMed and Embase databases identified 27 studies relevant to this meta-analysis. There was statistical significance for total, solid and lung cancers, with meta-SMR values of 0.88, 0.80, and 0.89, respectively. There was evidence of stochastic effects by IR, but more definitive conclusions require additional analyses using standardized protocols to determine whether LDIR increases the risk of solid cancer-related mortality. PMID:29725540
Inhaled corticosteroids in children with persistent asthma: effects on growth.
Zhang, Linjie; Prietsch, Sílvio O M; Ducharme, Francine M
2014-07-17
Treatment guidelines for asthma recommend inhaled corticosteroids (ICS) as first-line therapy for children with persistent asthma. Although ICS treatment is generally considered safe in children, the potential systemic adverse effects related to regular use of these drugs have been and continue to be a matter of concern, especially the effects on linear growth. To assess the impact of ICS on the linear growth of children with persistent asthma and to explore potential effect modifiers such as characteristics of available treatments (molecule, dose, length of exposure, inhalation device) and of treated children (age, disease severity, compliance with treatment). We searched the Cochrane Airways Group Specialised Register of trials (CAGR), which is derived from systematic searches of bibliographic databases including CENTRAL, MEDLINE, EMBASE, CINAHL, AMED and PsycINFO; we handsearched respiratory journals and meeting abstracts. We also conducted a search of ClinicalTrials.gov and manufacturers' clinical trial databases to look for potential relevant unpublished studies. The literature search was conducted in January 2014. Parallel-group randomised controlled trials comparing daily use of ICS, delivered by any type of inhalation device for at least three months, versus placebo or non-steroidal drugs in children up to 18 years of age with persistent asthma. Two review authors independently performed study selection, data extraction and assessment of risk of bias in included studies. We conducted meta-analyses using the Cochrane statistical package RevMan 5.2 and Stata version 11.0. We used the random-effects model for meta-analyses. We used mean differences (MDs) and 95% CIs as the metrics for treatment effects. A negative value for MD indicates that ICS have suppressive effects on linear growth compared with controls. We performed a priori planned subgroup analyses to explore potential effect modifiers, such as ICS molecule, daily dose, inhalation device and age of the treated child. We included 25 trials involving 8471 (5128 ICS-treated and 3343 control) children with mild to moderate persistent asthma. Six molecules (beclomethasone dipropionate, budesonide, ciclesonide, flunisolide, fluticasone propionate and mometasone furoate) [corrected] given at low or medium daily doses were used during a period of three months to four to six years. Most trials were blinded and over half of the trials had drop out rates of over 20%.Compared with placebo or non-steroidal drugs, ICS produced a statistically significant reduction in linear growth velocity (14 trials with 5717 participants, MD -0.48 cm/y, 95% CI -0.65 to -0.30, moderate quality evidence) and in the change from baseline in height (15 trials with 3275 participants; MD -0.61 cm/y, 95% CI -0.83 to -0.38, moderate quality evidence) during a one-year treatment period.Subgroup analysis showed a statistically significant group difference between six molecules in the mean reduction of linear growth velocity during one-year treatment (Chi² = 26.1, degrees of freedom (df) = 5, P value < 0.0001). The group difference persisted even when analysis was restricted to the trials using doses equivalent to 200 μg/d hydrofluoroalkane (HFA)-beclomethasone. Subgroup analyses did not show a statistically significant impact of daily dose (low vs medium), inhalation device or participant age on the magnitude of ICS-induced suppression of linear growth velocity during a one-year treatment period. However, head-to-head comparisons are needed to assess the effects of different drug molecules, dose, inhalation device or patient age. No statistically significant difference in linear growth velocity was found between participants treated with ICS and controls during the second year of treatment (five trials with 3174 participants; MD -0.19 cm/y, 95% CI -0.48 to 0.11, P value 0.22). Of two trials that reported linear growth velocity in the third year of treatment, one trial involving 667 participants showed similar growth velocity between the budesonide and placebo groups (5.34 cm/y vs 5.34 cm/y), and another trial involving 1974 participants showed lower growth velocity in the budesonide group compared with the placebo group (MD -0.33 cm/y, 95% CI -0.52 to -0.14, P value 0.0005). Among four trials reporting data on linear growth after treatment cessation, three did not describe statistically significant catch-up growth in the ICS group two to four months after treatment cessation. One trial showed accelerated linear growth velocity in the fluticasone group at 12 months after treatment cessation, but there remained a statistically significant difference of 0.7 cm in height between the fluticasone and placebo groups at the end of the three-year trial.One trial with follow-up into adulthood showed that participants of prepubertal age treated with budesonide 400 μg/d for a mean duration of 4.3 years had a mean reduction of 1.20 cm (95% CI -1.90 to -0.50) in adult height compared with those treated with placebo. Regular use of ICS at low or medium daily doses is associated with a mean reduction of 0.48 cm/y in linear growth velocity and a 0.61-cm change from baseline in height during a one-year treatment period in children with mild to moderate persistent asthma. The effect size of ICS on linear growth velocity appears to be associated more strongly with the ICS molecule than with the device or dose (low to medium dose range). ICS-induced growth suppression seems to be maximal during the first year of therapy and less pronounced in subsequent years of treatment. However, additional studies are needed to better characterise the molecule dependency of growth suppression, particularly with newer molecules (mometasone, ciclesonide), to specify the respective role of molecule, daily dose, inhalation device and patient age on the effect size of ICS, and to define the growth suppression effect of ICS treatment over a period of several years in children with persistent asthma.
Caffeine is a risk factor for osteopenia of prematurity in preterm infants: a cohort study.
Ali, Ebtihal; Rockman-Greenberg, Cheryl; Moffatt, Michael; Narvey, Michael; Reed, Martin; Jiang, Depeng
2018-01-22
Caffeine, the most commonly used medication in Neonatal Intensive Care Units, has calciuric and osteoclastogenic effects. To examine the association between the cumulative dose and duration of therapy of caffeine and osteopenia of prematurity, a retrospective cohort study was conducted including premature infants less than 31 weeks and birth weight less than 1500 g. Osteopenia of prematurity was evaluated using chest X-rays on a biweekly basis over 12 weeks of hospitalization. The cohort included 109 infants. 51% had osteopenia of prematurity and 8% had spontaneous rib fractures. Using the generalized linear mixed model, caffeine dose and duration of caffeine therapy showed a strong association with osteopenia of prematurity. Steroids and vitamin D were also significantly correlated with osteopenia of prematurity while diuretic use did not show a statistically significant effect. The cumulative dose and duration of therapy of caffeine, as well as steroid are associated with osteopenia of prematurity in this cohort. Future studies are needed to confirm these findings and determine the lowest dose of caffeine needed to treat effectively apnea of prematurity.
Li, Rong-cheng; Li, Feng-xiang; Li, Yan-ping
2009-06-01
To evaluate the safety and immunogenicity of the booster dose of 7 valent pneumococcal conjugate vaccine (PCV7) to the healthy Chinese toddlers who had received 3 primary doses. Four hundred and eighty-eight Chinese toddlers received a booster dose of PCV7 at age of 12-15 months following a primary series of the vaccine given at ages 3, 4, 5 months separately with Diphtheria Tetanus Acellular Pertussis Combined Vaccine (DTaP) in Group 1 or concurrently with DTaP in Group 2. Following the booster dose immunization, each subject was followed up for 30 days to observe the safety of the vaccine. Blood samples were taken from a subset of subjects prior and post 30 days the booster dose immunization to evaluate immunogenicity. A high proportion of subjects in Group 1 (89%) and Group 2 (91%) remained afebrile after the booster dose. Local reactions to the PCV7 booster dose were generally mild. For each serotype, the rise in GMC (post-/pre-vaccination) showed a statistically significant difference (P<0.0001) between both groups. PCV7 administered as a booster dose is generally safe, well tolerate, and immunogenic in healthy Chinese toddlers.
Karunakaran, C S
1980-10-01
A controlled trial of chloroquine prophylaxis was carried out to find whether this drug could be administered at intervals longer than the conventional ones recommended, in endemic malarious areas. Statistically significant results obtained show that chloroquine at suitable doses could be used successfully at intervals of 3 months. The possibility of chloroquine and acquired immunity acting together synergistically is discussed. The author is of the opinion that with this dose regime, the community would still be able to build up substantial immunity, so that in the event of the drug being discontinued, the community would not be faced with the problem of overwhelming malarial infections. The various advantages in using this regime are also considered.
Radon and leukemia in the Danish study: another source of dose.
Harley, Naomi H; Robbins, Edith S
2009-10-01
An epidemiologic study of childhood leukemia in Denmark (2,400 cases; 6,697 controls) from 1968 to 1994 suggested a weak, but statistically significant, association of residential radon exposure and acute childhood lymphoblastic leukemia (ALL). The Danish study estimated a relative risk (RR) = 1.56 (95% CI, 1.05-2.30) for a cumulative exposure of 1,000 Bq m-3 y. For an exposure duration of 10 y their RR corresponds to a radon concentration of 100 Bq m-3. There are two dose pathways of interest where alpha particles could damage potential stem cells for ALL. One is the alpha dose to bone marrow, and two is the dose to bronchial mucosa where an abundance of circulating lymphocytes is found. Compared with an exposure of about 1 mSv y-1 from natural external background, radon and decay products contribute an additional 10 to 60% to the bone marrow equivalent dose. The other pathway for exposure of T (or B) lymphocytes is within the tracheobronchial epithelium (BE). Inhaled radon decay products deposit on the relatively small area of airway surfaces and deliver a significant dose to the nearby basal or mucous cells implicated in human lung cancer. Lymphocytes are co-located with basal cells and are half as abundant. Using a 10-y exposure to 100 Bq m-3, our dose estimates suggest that the equivalent dose to these lymphocytes could approach 1 Sv. The relatively high dose estimate to lymphocytes circulating through the BE, potential precursor cells for ALL, provides a dose pathway for an association.
Arduino, Paolo G; Tirone, Federico; Schiorlin, Emanuele; Esposito, Marco
2015-01-01
To evaluate the difference between a single preoperative dose versus an additional two-day postoperative course of oral amoxicillin in patients undergoing conventional dental implant placement. Two dentists in two different private practices conducted this study. One hour prior to surgery, patients had to take a single prophylactic antibiotic dose, consisting of 2 g of amoxicillin orally; after implant placement, patients were randomly allocated to two different groups: protocol A (no other antibiotic administration) and protocol B, (1 g of amoxicillin in the evening of the day of surgery and 1 g twice a day for the 2 days after). Outcome measures were prosthetic and implant failures, adverse events and early postoperative complications. Patients were followed up to 6 months after functional loading. Three hundred and sixty patients were randomised and treated (192 patients in one centre and 168 in the other). Five hundred and sixty-seven implants were placed. Protocol A was applied to 180 patients (278 implants) and protocol B also to 180 patients (289 implants). Data for 17 patients, 14 from protocol A and three from protocol B, were not available. No statistically significant differences were found for the reported outcomes. Two patients of protocol B experienced a prosthetic failure, losing four implants, while no prosthetic failures were reported for protocol A (P=0.4836; difference in proportions=-0.0110; 95% CI: -0.0412 to 0.0119). Five patients (3.0%) of protocol A lost five implants versus 5 patients (2.8%) who lost eight implants in protocol B (P=1.0000; difference in proportions=0.0020; 95% CI: -0.0384 to 0.0438). Three adverse events were observed in the total population, all occurring in protocol B (1.69%), with no statistically significant differences between the two groups (P=0.1199; difference in proportions=-0.0170; 95% CI: -0.0487 to 0.0059). However, one patient experienced a severe allergic reaction requiring therapy discontinuation and hospital admission. Early postoperative complications occurred in six patients of protocol A and in four patients of protocol B, with no statistically significant differences (P=0.5170; difference in proportions=0.0130; 95% CI: -0.0254 to 0.0568). No statistically significant differences were observed between 2 g of preoperative amoxicillin and an additional 2-day postoperative course, although adverse events were reported only in the additional 2-day postoperative group. Based on these findings, it might be sufficient to routinely administer preoperatively 2 g of amoxicillin to patients undergoing routine dental implant placement procedures rather than administering additional postoperative doses.
Induction prednisone dosing for childhood nephrotic syndrome: how low should we go?
Sibley, Matthew; Roshan, Abishek; Alshami, Alanoud; Catapang, Marisa; Jöbsis, Jasper J; Kwok, Trevor; Polderman, Nonnie; Sibley, Jennifer; Matsell, Douglas G; Mammen, Cherry
2018-05-22
Historically, children with nephrotic syndrome (NS) across British Columbia (BC), Canada have been cared for without formal standardization of induction prednisone dosing. We hypothesized that local historical practice variation in induction dosing was wide and that children treated with lower doses had worse relapsing outcomes. This retrospective cohort study included 92 NS patients from BC Children's Hospital (1990-2010). We excluded secondary causes of NS, age < 1 year at diagnosis, steroid resistance, and incomplete induction due to early relapse. We explored cumulative induction dose and defined dosing quartiles. Relapsing outcomes above and below each quartile threshold were compared including total relapses in 2 years, time to first relapse, and proportions developing frequently relapsing NS (FRNS) or starting a steroid-sparing agent (SSA). Cumulative prednisone was widely distributed with approximated median, 1st, and 3rd quartile doses of 2500, 2000, and 3000 mg/m 2 respectively. Doses ≤ 2000 mg/m 2 showed significantly higher relapses (4.2 vs 2.7), shorter time to first relapse (61 vs 175 days), and higher SSA use (36 vs 14%) compared to higher doses. Doses ≤ 2500 mg/m 2 also showed significantly more relapses (3.9 vs 2.2), quicker first relapse (79 vs 208 days), and higher FRNS (37 vs 17%) and SSA use (28 vs 11%). Relapsing outcomes lacked statistical difference in ≤ 3000 vs > 3000 mg/m 2 doses. Results strongly justify our development of a standardized, province-wide NS clinical pathway to reduce practice variation and minimize under-treatment. The lowest induction prednisone dosing threshold to minimize future relapsing risks is likely between 2000 and 2500 mg/m 2 . Further prospective studies are warranted.
Impact of the Amount of Liquid Intake on the Dose Rate of Patients Treated with Radioiodine.
Haghighatafshar, Mahdi; Banani, Aida; Zeinali-Rafsanjani, Banafsheh; Etemadi, Zahra; Ghaedian, Tahereh
2018-01-01
Despite therapeutic effects of radioiodine in patients with differentiated thyroid cancer, there are some disadvantages due to harmful radiation to other tissues. According to the current guidelines, patients are recommended to drink lots of water and frequent voiding to reduce the amount of 131 I in the body. This study was designed to assess the impact of the amount of liquid intake on reduction of the measured dose rate of radioiodine-treated patients. A total of 42 patients with differentiated thyroid cancer without metastasis who had undergone total thyroidectomy and had been treated with radioiodine were selected. The patients were divided into two groups according to the amount of their fluid intake which was measured during the first 48 h after 131 I administration. In all patients, the dose rate was measured immediately and 48 h after iodine administration. Each group included 21 patients. Dose rate ratio (the ratio of the second dose rate to the first dose rate) and dose rate difference ratio (the ratio of the difference between the two measured dose rates to the first dose rate) were calculated for each patient. Despite the significant difference in the amount of the liquid drunk, no statistically significant difference was seen between the different groups in parameters of dose-rate ratio and dose-rate difference ratio. Higher fluid intake (>60 ml/h in our study) alone would not effectively reduce the patient's radiation dose rate at least not more than a well-hydrated state. It seems that other interfering factors in the thyroidectomized patients may also have some impacts on this physiologic process.
Wang, Kang-Ling; Giugliano, Robert P; Goto, Shinya; Chiu, Chun-Chih; Lin, Chun-Yi; Lai, En-Yu; Chiang, Chern-En
2016-12-01
Although randomized controlled trials (RCTs) indicated that standard dose non-vitamin K antagonist oral anticoagulants (NOACs) were more compelling, low dose NOACs are commonly used in clinical practice in Asia. The purpose of this study was to assess the relative therapeutic benefit and risk of standard dose vs low dose NOACs in Asian patients enrolled in contemporary RCTs. We performed a prespecified meta-analysis of 3155 Asian patients with NOACs in the RE-LY (Randomized Evaluation of Long-Term Anticoagulation Therapy) and ENGAGE AF-TIMI 48 (Effective Anticoagulation with Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) trials. Efficacy and safety with standard dose vs low dose NOACs were compared by risk ratios (RRs) and 95% confidence intervals (CIs) in a random-effects model. An evidence network incorporating additional Asian patients from ROCKET AF, J- ROCKET AF, and ARISTOTLE was constructed with the Bayesian method. Risks of stroke or systemic embolism and ischemic stroke were significantly reduced with standard dose vs low dose NOACs (RR 0.62, 95% CI 0.45-0.85; and RR 0.55, 95% CI 0.38-0.79, respectively). Rates of major, intracranial, and life-threatening bleeding with 2 dosing regimens were broadly similar (RR 1.31, 95% CI 0.74-2.33; RR 1.54, 95% CI 0.72-3.30; and RR 1.49, 95% CI 0.87-2.55, respectively). Absolute rates of all-cause mortality and the net clinical outcome with standard dose NOACs were lower but not statistically significant (absolute reduction 0.4% per year and 1.1% per year, respectively). Network meta-analyses demonstrated that standard dose NOACs had the most favorable risk-benefit profile among oral anticoagulants. In Asian patients, standard dose NOACs represent a more appealing therapeutic option than low dose NOACs, with a significant reduction in ischemic stroke without an excess of major bleeding. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Pyridostigmine in the treatment of orthostatic intolerance.
Gales, Barry J; Gales, Mark A
2007-02-01
To review the efficacy of pyridostigmine bromide for the treatment of orthostatic intolerance. MEDLINE and International Pharmaceutical Abstracts were searched (1966-December 2006) using the terms pyridostigmine, acetylcholinesterase inhibitor, orthostatic intolerance, orthostatic hypotension, neurogenic orthostatic hypotension, postural tachycardia syndrome, tachycardia, and orthostatic tachycardia. Pertinent English-language human clinical trials, case reports, and background material were evaluated for safety and efficacy data. The references of reviewed articles were reviewed and used to identify additional sources. Pyridostigmine bromide has been associated with improved baroreceptor sensitivity and presents a novel approach to treatment of orthostatic intolerance. Four single-dose trials and a follow-up survey encompassing a total of 106 patients were identified. One open-label and one placebo-controlled single-dose trial in patients with neurogenic orthostatic hypotension (NOH) found statistically significant improvement in standing diastolic blood pressures (DBP). Absolute improvements in standing DBP were 3.7 and 6.4 mm Hg in the open-label and controlled trials, respectively. Long-term data consist of a single survey of patients receiving open-label pyridostigmine bromide. Twenty-nine percent of patients who initiated maintenance pyridostigmine bromide discontinued therapy. Concomitant NOH medications were taken by 75% of patients, and 85% of patients reported receiving benefit from pyridostigmine bromide. When evaluated for postural tachycardia syndrome, pyridostigmine bromide significantly reduced standing heart rate (10%). Pyridostigmine bromide significantly reduced symptom scores when compared with baseline but not placebo. The majority of patients included in these trials did not have supine hypertension. Single doses of pyridostigmine bromide produced modest but statistically significant improvements in hemodynamic measurements. At this time, long-term data are insufficient to support recommending the routine use of pyridostigmine bromide for treatment of orthostatic intolerance.
Hodis, Howard N; Mack, Wendy J; Dustin, Laurie; Mahrer, Peter R; Azen, Stanley P; Detrano, Robert; Selhub, Jacob; Alaupovic, Petar; Liu, Chao-ran; Liu, Ci-hua; Hwang, Juliana; Wilcox, Alison G; Selzer, Robert H
2009-03-01
Although plasma total homocysteine (tHcy) levels are associated with cardiovascular disease, it remains unclear whether homocysteine is a cause or a marker of atherosclerotic vascular disease. We determined whether reduction of tHcy levels with B vitamin supplementation reduces subclinical atherosclerosis progression. In this double-blind clinical trial, 506 participants 40 to 89 years of age with an initial tHcy >8.5 micromol/L without diabetes and cardiovascular disease were randomized to high-dose B vitamin supplementation (5 mg folic acid+0.4 mg vitamin B(12)+50 mg vitamin B(6)) or matching placebo for 3.1 years. Subclinical atherosclerosis progression across 3 vascular beds was assessed using high-resolution B-mode ultrasonography to measure carotid artery intima media thickness (primary outcome) and multidetector spiral CT to measure aortic and coronary artery calcium (secondary outcome). Although the overall carotid artery intima media thickness progression rate was lower with B vitamin supplementation than with placebo, statistically significant between-group differences were not found (P=0.31). However, among subjects with baseline tHcy >or=9.1 micromol/L, those randomized to B vitamin supplementation had a statistically significant lower average rate of carotid artery intima media thickness progression compared with placebo (P=0.02); among subjects with a baseline tHcy <9.1 micromol/L, there was no significant treatment effect (probability value for treatment interaction=0.02). B vitamin supplementation had no effect on progression of aortic or coronary artery calcification overall or within subgroups. High-dose B vitamin supplementation significantly reduces progression of early-stage subclinical atherosclerosis (carotid artery intima media thickness) in well-nourished healthy B vitamin "replete" individuals at low risk for cardiovascular disease with a fasting tHcy >or=9.1 micromol/L.
Lack of efficacy of levetiracetam in oromandibular and cranial dystonia.
Park, J E; Srivanitchapoom, P; Maurer, C W; Mathew, P; Sackett, J; Paine, R; Ramos, V L; Hallett, M
2017-08-01
To determine the efficacy of levetiracetam in oromandibular or cranial dystonia. We recruited seven subjects with oromandibular or cranial dystonia. Five completed the study, median age was 71 years (range 42-79 years), median disease duration was 12 years (range 2-30 years). Participants were randomized to receive levetiracetam or placebo and were then crossed over. They titrated up to a total daily dose of 4000 mg or the maximum tolerated dose over 3 weeks and maintained that dose for another 3 weeks. The primary endpoint was the percent change of the eyes, mouth, speech, and swallowing Burke-Fahn-Marsden (BFM) subscores from baseline to weeks 6 and 14. Additional endpoints included the BFM subscore at weeks 3 and 11, and the global dystonia severity (GDS) subscore at weeks 3, 6, 11, and 14, as well as all adverse side effects. The mean percent increase in the BFM subscore (placebo: 31.25%, levetiracetam: 12.16%) was not significantly different between the two arms according to the Friedman analysis. The Wilcoxon signed-rank test showed that these percent changes were not significant, indicating that there was no statistical clinical worsening in either arm. The mean percent change of the BFM subscore at weeks 3 and 11 and the mean percent change of the GDS subscore at weeks 3, 6, 11, and 14 were not significantly different between the two arms, and the Wilcoxon signed-rank test did not show statistical significance. Levetiracetam does not appear to be efficacious in patients with oromandibular or cranial dystonia. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mestrovic, Ante; Clark, Brenda G.; Department of Medical Physics, British Columbia Cancer Agency, Vancouver, British Columbia
2005-11-01
Purpose: To develop a method of predicting the values of dose distribution parameters of different radiosurgery techniques for treatment of arteriovenous malformation (AVM) based on internal geometric parameters. Methods and Materials: For each of 18 previously treated AVM patients, four treatment plans were created: circular collimator arcs, dynamic conformal arcs, fixed conformal fields, and intensity-modulated radiosurgery. An algorithm was developed to characterize the target and critical structure shape complexity and the position of the critical structures with respect to the target. Multiple regression was employed to establish the correlation between the internal geometric parameters and the dose distribution for differentmore » treatment techniques. The results from the model were applied to predict the dosimetric outcomes of different radiosurgery techniques and select the optimal radiosurgery technique for a number of AVM patients. Results: Several internal geometric parameters showing statistically significant correlation (p < 0.05) with the treatment planning results for each technique were identified. The target volume and the average minimum distance between the target and the critical structures were the most effective predictors for normal tissue dose distribution. The structure overlap volume with the target and the mean distance between the target and the critical structure were the most effective predictors for critical structure dose distribution. The predicted values of dose distribution parameters of different radiosurgery techniques were in close agreement with the original data. Conclusions: A statistical model has been described that successfully predicts the values of dose distribution parameters of different radiosurgery techniques and may be used to predetermine the optimal technique on a patient-to-patient basis.« less
2011-01-01
Introduction We report the impact of canakinumab, a fully human anti-interleukin-1β monoclonal antibody, on inflammation and health-related quality of life (HRQoL) in patients with difficult-to-treat Gouty Arthritis. Methods In this eight-week, single-blind, double-dummy, dose-ranging study, patients with acute Gouty Arthritis flares who were unresponsive or intolerant to - or had contraindications for - non-steroidal anti-inflammatory drugs and/or colchicine were randomized to receive a single subcutaneous dose of canakinumab (10, 25, 50, 90, or 150 mg) (N = 143) or an intramuscular dose of triamcinolone acetonide 40 mg (N = 57). Patients assessed pain using a Likert scale, physicians assessed clinical signs of joint inflammation, and HRQoL was measured using the 36-item Short-Form Health Survey (SF-36) (acute version). Results At baseline, 98% of patients were suffering from moderate-to-extreme pain. The percentage of patients with no or mild pain was numerically greater in most canakinumab groups compared with triamcinolone acetonide from 24 to 72 hours post-dose; the difference was statistically significant for canakinumab 150 mg at these time points (P < 0.05). Treatment with canakinumab 150 mg was associated with statistically significant lower Likert scores for tenderness (odds ratio (OR), 3.2; 95% confidence interval (CI), 1.27 to 7.89; P = 0.014) and swelling (OR, 2.7; 95% CI, 1.09 to 6.50, P = 0.032) at 72 hours compared with triamcinolone acetonide. Median C-reactive protein and serum amyloid A levels were normalized by seven days post-dose in most canakinumab groups, but remained elevated in the triamcinolone acetonide group. Improvements in physical health were observed at seven days post-dose in all treatment groups; increases in scores were highest for canakinumab 150 mg. In this group, the mean SF-36 physical component summary score increased by 12.0 points from baseline to 48.3 at seven days post-dose. SF-36 scores for physical functioning and bodily pain for the canakinumab 150 mg group approached those for the US general population by seven days post-dose and reached norm values by eight weeks post-dose. Conclusions Canakinumab 150 mg provided significantly greater and more rapid reduction in pain and signs and symptoms of inflammation compared with triamcinolone acetonide 40 mg. Improvements in HRQoL were seen in both treatment groups with a faster onset with canakinumab 150 mg compared with triamcinolone acetonide 40 mg. Trial registration clinicaltrials.gov: NCT00798369. PMID:21439048
Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A
2015-01-01
The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring size (P < 0.0001) and dose level (P < 0.0001). The number of voxels in the region of interest for the particular material studied did not demonstrate a significant effect (P > 0.05). The SD was lower with ADMIRE compared with WFBP at all dose levels and ring sizes (P < 0.05). The third-generation dual-source CT scanners using third-generation iterative reconstruction methods can acquire accurate quantitative CT images with acceptable image noise at very low-dose levels (0.15 mGy). This opens up new diagnostic and research opportunities in CT phenotyping of the lung for developing new treatments and increased understanding of pulmonary disease.
Thomas, Kimberly M; Maquilan, Genevieve; Stojadinovic, Strahinja; Medin, Paul; Folkert, Michael R; Albuquerque, Kevin
Brachytherapy (BT) techniques have historically used a two-dimensional nonvolumetric (NV) system involving dose prescribed to a point fixed in space. We compared dosimetric, toxicity, and oncologic outcomes for volumetric planning (3DV) versus CT point-based planning. Patients treated with external beam radiation therapy and high dose rate (HDR) intracavitary BT were included (n = 71). Patients planned with NV BT treated from 2009 to 2011 (n = 37) were compared to patients planned with 3DV BT treated from 2012 to 2014 (n = 34). Investigators delineated volumes for organs at risk clinical target volumes for the 2009-2011 NV cohort. Acute and chronic toxicity data were graded. The mean HDR clinical target volume D90 received in the NV and 3DV cohorts were significantly different (p < 0.001). The mean dose to point A was significantly higher in the NV cohort than in the 3DV cohort (p < 0.001). There were significantly more Grade 3 or higher gastrointestinal toxicities in the NV cohort (p = 0.048). There was a nonsignificant trend toward improved oncologic outcomes for patients undergoing CT-based planning. 3DV BT allows for a significant reduction of dose to critical structures, resulting in decreased gastrointestinal toxicity, while delivering noninferior doses to the high-risk clinical target volume. Outcomes were improved in the 3D cohort trending toward statistical significance. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dogan, N; Denissova, S
2016-06-15
Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% tomore » 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.« less
Afzal, Muhammad Faheem; Sultan, Muhammad Ashraf; Saleemi, Ahmad Imran
2016-01-01
Diseases caused by Hepatitis B virus (HBV) have a worldwide distribution. Pakistan adopted the recommendations of World Health Organization (WHO) for routine universal infant vaccination against hepatitis B in 2002, currently being administered at 6, 10, and 14 weeks of age in a combination vaccine. This study was conducted to determine the immune response & anamnestic immune response in children, 9 months-10 years of age, after a 3dose primary Hepatitis B vaccination. This cross sectional study was conducted in the Department of Paediatrics, King Edward Medical University/Mayo Hospital, Lahore, Pakistan, from January to June, 2014. A total of 200 children of either sex between the ages of 9 months to 10 years, documented to have received 3 doses of hepatitis B vaccines according to Expanded Program of Immunization (6,10,14 weeks) schedule in infancy, were recruited by consecutive sampling. The level of serum antiHBsAb by ELIZA was measured. Children with antiHBs titers ≥10 mIU/mL were considered to be immune. Those with anti HBsAb levels <10 mIU/mL were offered a booster dose of infant recombinant hepatitis B vaccine. The second serum sample was obtained 21-28 days following the administration of the booster dose and the anamnestic immune response was measured. Data was analysed using SPSS 17 to determine the relation between time interval since last vaccination and antibody titer. Chi square test was applied. Of the 200 children, protective antibody response was found in 58%. Median serological response was 18.60 (range 2.82 - 65.15). Antibody levels were found to have a statistically significant ( pvalue 0.019) negative correlation with the time since last administration of vaccine. A booster dose of Hepatitis B vacci ne was administered to all nonresponders, with each registering a statistically significant (pvalue 0.00) anamnestic response. The vaccination schedule with short dosage interval was unable to provide protection to 42% of the study population. Introduction of birth dose of Hepatitis B vaccine to the existing schedule is recommended.
Modeling Rabbit Responses to Single and Multiple Aerosol ...
Journal Article Survival models are developed here to predict response and time-to-response for mortality in rabbits following exposures to single or multiple aerosol doses of Bacillus anthracis spores. Hazard function models were developed for a multiple dose dataset to predict the probability of death through specifying dose-response functions and the time between exposure and the time-to-death (TTD). Among the models developed, the best-fitting survival model (baseline model) has an exponential dose-response model with a Weibull TTD distribution. Alternative models assessed employ different underlying dose-response functions and use the assumption that, in a multiple dose scenario, earlier doses affect the hazard functions of each subsequent dose. In addition, published mechanistic models are analyzed and compared with models developed in this paper. None of the alternative models that were assessed provided a statistically significant improvement in fit over the baseline model. The general approach utilizes simple empirical data analysis to develop parsimonious models with limited reliance on mechanistic assumptions. The baseline model predicts TTDs consistent with reported results from three independent high-dose rabbit datasets. More accurate survival models depend upon future development of dose-response datasets specifically designed to assess potential multiple dose effects on response and time-to-response. The process used in this paper to dev
Gosiewski, Tomasz; Mróz, Tomasz; Ochońska, Dorota; Pabian, Wojciech; Bulanda, Malgorzata; Brzychczy-Wloch, Monika
2016-05-31
Ionizing radiation is used as a therapeutic option in the treatment of certain neoplastic lesions located, among others, in the pelvic region. The therapeutic doses of radiation employed often result in adverse effects manifesting themselves primarily in the form of genital tract infections in patients or diarrhea. The data available in the literature indicate disorders in the microbial ecosystem caused by ionizing radiation, which leads to the problems mentioned above. In the present study, we examined the influence of ionizing radiation on 52 selected strains of bacteria: Lactobacillus crispatus, L. fermentum, L. plantarum, L. reuteri, L. acidophilus L. amylovorus, L. casei, L. helveticus, L. paracasei, L. rhamnosus, L. salivarius and L. gasseri. This collection of Lactobacillus bacteria isolates of various species, obtained from the genital tract and gastrointestinal tract of healthy women, was tested for resistance to therapeutic doses of ionizing radiation. The species studied, were isolated from the genital tract (n = 30) and from the anus (n = 22) of healthy pregnant women. Three doses of 3 Gy (fractionated dose) and 50 Gy (total dose of the whole radiotherapy cycle) were applied. The greatest differences in survival of the tested strains in comparison to the control group (not subjected to radiation) were observed at the dose of 50 Gy. However, the results were not statistically significant. Survival decrease to zero was not demonstrated for any of the tested strains. Therapeutic doses of radiation do not affect the Lactobacillus bacteria significantly.
Crowe, Scott B; Kairn, Tanya; Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T; Kenny, John; Langton, Christian M; Trapp, Jamie V
2013-01-01
Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. PMID:26229621
NASA Astrophysics Data System (ADS)
Yong, J. S.; Ung, N. M.; Jamalludin, Z.; Malik, R. A.; Wong, J. H. D.; Liew, Y. M.; Ng, K. H.
2016-02-01
We investigated the dosimetric impact of applicator displacement on dose specification during high dose rate (HDR) Cobalt-60 (Co-60) brachytherapy for cervical cancer through a planning study. Eighteen randomly selected HDR full insertion plans were restrospectively studied. The tandem and ovoids were virtually shifted translationally and rotationally in the x-, y- and z-axis directions on the treatment planning system. Doses to reference points and volumes of interest in the plans with shifted applicators were compared with the original plans. The impact of dose displacement on 2D (point-based) and 3D (volume-based) treatment planning techniques was also assessed. A ±2 mm translational y-axis applicator shift and ±4° rotational x-axis applicator shift resulted in dosimetric changes of more than 5% to organs at risk (OAR) reference points. Changes to the maximum doses to 2 cc of the organ (D2cc) in 3D planning were statistically significant and higher than the reference points in 2D planning for both the rectum and bladder (p<0.05). Rectal D2cc was observed to be the most sensitive to applicator displacement among all dose metrics. Applicator displacement that is greater than ±2 mm translational y-axis and ±4° rotational x-axis resulted in significant dose changes to the OAR. Thus, steps must be taken to minimize the possibility of applicator displacement during brachytherapy.
[Mechanism study on leptin resistance in lung cancer cachexia rats treated by Xiaoyan Decoction].
Zhang, Yun-Chao; Jia, Ying-Jie; Yang, Pei-Ying; Zhang, Xing; Li, Xiao-Jiang; Zhang, Ying; Zhu, Jin-Li; Sun, Yi-Yu; Chen, Jun; Duan, Hao-Guo; Guo, Hua; Li, Chao
2014-12-01
To study the leptin resistance mechanism of Xiaoyan Decoction (XD) in lung cancer cachexia (LCC) rats. An LCC rat model was established. Totally 40 rats were randomly divided into the normal control group, the LCC model group, the XD group, and the positive control group, 10 in each group. After LCC model was set up, rats in the LCC model group were administered with normal saline, 2 mL each time. Rats in the XD group were administered with XD at the daily dose of 2 mL. Those in the positive control group were administered with Medroxyprogesterone Acetate suspension (20 mg/kg) by gastrogavage at the daily dose of 2 mL. All medication lasted for 14 days. The general condition and tumor growth were observed. Serum levels of leptin and leptin receptor in the hypothalamus were detected using enzyme-linked immunosorbent assay. Contents of neuropeptide Y (NPY) and anorexia for genomic POMC were detected using real-time PCR technique. Serum leptin levels were lower in the LCC model group than in the normal control group with statistical significance (P < 0.05). Compared with the LCC model groups, serum leptin levels significantly increased in the XD group (P < 0.01). Leptin receptor levels in the hypothalamus increased significantly in the LCC model group (P < 0.01). Increased receptor levels in the LCC model group indicated that either XD or Medroxyprogesterone Acetate could effectively reduce levels of leptin receptor with statistical significance (P < 0.01). There was also statistical difference between the XD group and the positive control group (P < 0.05). Contents of NPY was higher in the LCC model group than in the other groups with statistical difference (P < 0.05). There was no statistical difference in NPY between the normal control group and the rest 2 treatment groups (P > 0.05). There was statistical difference in POMC between the normal control group and the LCC model group (P < 0.05). POMC could be decreased in the XD group and the positive control group with statistical significance (P < 0.05), and it was more obviously decreased in the XD group (P < 0.05). Leptin resistance existed in LCC rats. XD could increase serum leptin levels and reduce leptin receptor levels in the hypothalamus. LCC could be improved by elevating NPY contents in the hypothalamus and reducing POMC contents, promoting the appetite, and increasing food intake from the periphery pathway and the central pathway.
Stier, Brendt; Fossler, Michael; Liu, Feng; Caltabiano, Stephen
2015-07-01
Retosiban is a small molecule oxytocin receptor antagonist that is under evaluation in clinical studies for treatment of spontaneous preterm labor. A Thorough QT/QTc study was conducted to evaluate the effect of retosiban on cardiac repolarization according to International Conference on Harmonization E14 guidance. This was a randomized, placebo- and positive-controlled, single-dose, crossover study of healthy men and women. All study participants received a 100 mg dose of retosiban (therapeutic target exposure), a 800 mg dose of retosiban (supratherapeutic target exposure), a 400 mg dose of moxifloxacin (positive control), and placebo with an appropriate washout. Holter monitoring data at baseline (predose) and at 13 subsequent time points during the next 24 hours were extracted and manually read by a central ECG reader who was blinded to the treatment assignment and corrected for heart rate by using the Fridericia formula (QTcF). A linear exposure-QTc response model was developed: ΔΔQTcF=RI+Cp,R⋅RS+MI+Cp,M⋅MS, where RI and MI are intercept terms for retosiban and moxifloxacin, respectively, RS and MS are slope terms for retosiban and moxifloxacin, respectively, and Cp,R and Cp,M are plasma concentrations for retosiban and moxifloxacin, respectively. A total of 52 healthy men (n = 27) and women (n = 25), with a mean age of 32 years, were enrolled in the study, and 43 (83%) completed all treatment periods and assessments. Mean placebo-corrected change from baseline QT (ΔΔQTcF) for the 2 retosiban dose groups revealed statistically significant decreases in ΔΔQTcF between 2 and 3 hours after administration, reaching a value of -2.5 msec for both retosiban dose groups. The 400 mg moxifloxacin group had a statistically significant increase in the ΔΔQTcF value at 0.75 hours after administration, reaching a maximal increase of 11.10 msec at 4 hours after administration. Results of the exposure-QTc response modeling revealed that there was no significant effect of retosiban on the ΔΔQTcF at therapeutic exposures. For the supratherapeutic exposure of retosiban, there was a slight negative effect, with a mean decrease of -3.05 msec. The moxifloxacin arm had a mean increase in ΔΔQTcF of 10.7 msec. At therapeutic and supratherapeutic exposures, retosiban had no significant effect on cardiac repolarization, as estimated by the ΔΔQTcF. However, both doses of retosiban had a minor shortening effect. This is not considered to be clinically significant. CLINICALTRIALS. NCT01702376. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.
Crescenti, Anna; Puiggròs, Francesc; Colomé, Arnau; Poch, Josep Antón; Caimari, Antoni; Bas, Josep Maria; Boqué, Noemí; Arola, Lluís
2015-12-01
To determine the effect of a botanical formulation of Herniaria glabra, Agropyron repens, Equisetum arvense, and Sambucus nigra as a preventive agent in an experimentally induced nefrolithiasis model in rats. Six groups of six Wistar male rats each were induced for nefrolithiasis by treatment with 0.75% ethylene glycol (EG) and 1% ammonium chloride for three days and then EG only for 15 days. One group was treated with placebo (control group) and the other groups (treated groups) were treated with 30 mg/Kg, 60 mg/Kg, 125 mg/Kg, 250 mg/Kg and 500 mg/Kg of the plant extract formulation (PEF). 24-h urine and water samples were collected one day before EG administration and at 7, 13 and 18 days to determine diuresis, crystalluria and urine biochemistry. The kidneys were removed for histological analysis. The phytochemical characterization of PEF and each of its component plant extracts was performed using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry. Animals treated with 125 mg/Kg of the PEF had statistically significantly lower calcium oxalate crystals deposits content compared to the control group. All PEF doses statistically significantly decreased the number of microcalcifications compared to the control group. Furthermore, the number of kidneys affected by subcapsular fibrosis was statistically significantly higher in control group than in treated groups with the PEF. The diuresis of the 125 mg/Kg and 500 mg/Kg PEF-treated groups was statistically significantly higher than that of the control group. A phytochemical analysis demonstrated the presence of flavonoids, dicarboxylic acids and saponins. Treatment with PEF prevents deposits of calcium oxalate crystals formation and of microcalcifications in the kidney, and reduces the risk of fibrosis subcapsular. 125 mg/Kg of PEF is the dose that has a greater effect on the studied parameters.
Fields, Emma C; Melvani, Rakhi; Hajdok, George; D'Souza, David; Jones, Bernard; Stuhr, Kelly; Diot, Quentin; Fisher, Christine M; Mukhopadhyay, Nitai; Todor, Dorin
2017-09-01
When brachytherapy doses are reported or added, biologically effective dose (BED) minimum dose covering 90% of the volume (D90) is used as if dose is delivered uniformly to the target. Unlike BED(D90), equivalent uniform BED (EUBED) and generalized biologically equivalent uniform dose (gBEUD) are quantities that integrate dose inhomogeneity. Here we compared BED(D90) and equivalent uniform BED (EUBED)/gBEUD in 3 settings: (1) 2 sites using tandem and ovoid (T&O) but different styles of implants; (2) 2 sites using different devices-T&O and tandem and ring (T&R)-and different styles; and (3) the same site using T&O and T&R with the same style. EUBED and gBEUD were calculated for 260 fractions from 3 institutions using BED(α/β = 10 Gy). EUBED uses an extra parameter α with smaller values associated with radioresistant tumors. Similarly, gBEUD uses a, which places variable emphasis on hot/cold spots. Distributions were compared using the Kolmogorov-Smirnoff test at 5% significance. For the 2 sites using T&O, the distribution of EUBED-BED(D90) was not different for values of α = 0.5 to 0.3 Gy -1 but was statistically different for values of α = 0.15 to 0.05 Gy -1 (P=.01, .002). The mean percentage differences between EUBED and BED(D90) ranged from 20% to 100% for α = 0.5 Gy -1 to 0.05 Gy -1 . Using gBEUD-BED(D90), the P values indicate the distributions to be similar for a = -10 but to be significantly different for other values of a (-5, -1, 1). Between sites and at the same site using T&O versus T&R, the distributions were statistically different with EUBED/gBEUD irrespective of parameter values at which these quantities were computed. These differences indicate that EUBED/gBEUD capture differences between the techniques and applicators that are not detected by the BED(D90). BED(D90) is unable to distinguish between plans created by different devices or optimized differently. EUBED/gBEUD distinguish between dose distributions created by different devices and styles of implant and planning. This discrepancy is particularly important with the increased use of magnetic resonance imaging and hybrid devices, whereby one has the ability to create dose distributions that are significant departures from the classic pear. Copyright © 2017 Elsevier Inc. All rights reserved.
Fontarensky, Mikael; Alfidja, Agaïcha; Perignon, Renan; Schoenig, Arnaud; Perrier, Christophe; Mulliez, Aurélien; Guy, Laurent; Boyer, Louis
2015-07-01
To evaluate the accuracy of reduced-dose abdominal computed tomographic (CT) imaging by using a new generation model-based iterative reconstruction (MBIR) to diagnose acute renal colic compared with a standard-dose abdominal CT with 50% adaptive statistical iterative reconstruction (ASIR). This institutional review board-approved prospective study included 118 patients with symptoms of acute renal colic who underwent the following two successive CT examinations: standard-dose ASIR 50% and reduced-dose MBIR. Two radiologists independently reviewed both CT examinations for presence or absence of renal calculi, differential diagnoses, and associated abnormalities. The imaging findings, radiation dose estimates, and image quality of the two CT reconstruction methods were compared. Concordance was evaluated by κ coefficient, and descriptive statistics and t test were used for statistical analysis. Intraobserver correlation was 100% for the diagnosis of renal calculi (κ = 1). Renal calculus (τ = 98.7%; κ = 0.97) and obstructive upper urinary tract disease (τ = 98.16%; κ = 0.95) were detected, and differential or alternative diagnosis was performed (τ = 98.87% κ = 0.95). MBIR allowed a dose reduction of 84% versus standard-dose ASIR 50% (mean volume CT dose index, 1.7 mGy ± 0.8 [standard deviation] vs 10.9 mGy ± 4.6; mean size-specific dose estimate, 2.2 mGy ± 0.7 vs 13.7 mGy ± 3.9; P < .001) without a conspicuous deterioration in image quality (reduced-dose MBIR vs ASIR 50% mean scores, 3.83 ± 0.49 vs 3.92 ± 0.27, respectively; P = .32) or increase in noise (reduced-dose MBIR vs ASIR 50% mean, respectively, 18.36 HU ± 2.53 vs 17.40 HU ± 3.42). Its main drawback remains the long time required for reconstruction (mean, 40 minutes). A reduced-dose protocol with MBIR allowed a dose reduction of 84% without increasing noise and without an conspicuous deterioration in image quality in patients suspected of having renal colic.
Dose-rate effects of ethylene oxide exposure on developmental toxicity.
Weller, E; Long, N; Smith, A; Williams, P; Ravi, S; Gill, J; Henessey, R; Skornik, W; Brain, J; Kimmel, C; Kimmel, G; Holmes, L; Ryan, L
1999-08-01
In risk assessment, evaluating a health effect at a duration of exposure that is untested involves assuming that equivalent multiples of concentration (C) and duration (T) of exposure have the same effect. The limitations of this approach (attributed to F. Haber, Zur Geschichte des Gaskrieges [On the history of gas warfare], in Funf Vortrage aus den Jahren 1920-1923 [Five lectures from the years 1920-1923], 1924, Springer, Berlin, pp. 76-92), have been noted in several studies. The study presented in this paper was designed to specifically look at dose-rate (C x T) effects, and it forms an ideal case study to implement statistical models and to examine the statistical issues in risk assessment. Pregnant female C57BL/6J mice were exposed, on gestational day 7, to ethylene oxide (EtO) via inhalation for 1.5, 3, or 6 h at exposures that result in C x T multiples of 2100 or 2700 ppm-h. EtO was selected because of its short half-life, documented developmental toxicity, and relevance to exposures that occur in occupational settings. Concurrent experiments were run with animals exposed to air for similar periods. Statistical analysis using models developed to assess dose-rate effects revealed significant effects with respect to fetal death and resorptions, malformations, crown-to-rump length, and fetal weight. Animals exposed to short, high exposures of EtO on day 7 of gestation were found to have more adverse effects than animals exposed to the same C x T multiple but at longer, lower exposures. The implication for risk assessment is that applying Haber's Law could potentially lead to an underestimation of risk at a shorter duration of exposure and an overestimation of risk at a longer duration of exposure. Further research, toxicological and statistical, are required to understand the mechanism of the dose-rate effects, and how to incorporate the mechanistic information into the risk assessment decision process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Raj, E-mail: rajdas@nhs.net, E-mail: raj.das@stgeorges.nhs.uk; Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com; Wang, Haofan, E-mail: wwhhff123@gmail.com
AimA clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill.MethodsTen IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to threemore » groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters).ResultsMean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %.ConclusionUAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.« less
Effects of alcohol mixed with energy drink and alcohol alone on subjective intoxication.
Ulbrich, Andrea; Hemberger, Sophie Helene; Loidl, Alexandra; Dufek, Stephanie; Pablik, Eleonore; Fodor, Sugarka; Herle, Marion; Aufricht, Christoph
2013-12-01
Recent studies suggest that the combination of caffeine-containing drinks together with alcohol might reduce the subjective feelings of alcohol intoxication-the so-called "masking effect". In this study, we aimed to review the effects of alcohol in combination with caffeine or energy drink with special focus on the "masking effect". Fifty-two healthy male volunteers were analysed concerning breath alcohol concentration and subjective sensations of intoxication using a 18 item Visual Analogue Scale in a randomised, double-blinded, controlled, four treatments cross-over trial after consumption of (A) placebo, (B) alcohol (vodka 37.5% at a dose of 46.5 g ethanol), (C) alcohol in combination with caffeine at a dose of 80 mg (equivalent to one 250 ml can of energy drink) and (D) alcohol in combination with energy drink at a dose of 250 ml (one can). Primary variables were headache, weakness, salivation and motor coordination. Out of four primary variables, weakness and motor coordination showed a statistically significant difference between alcohol and non-alcohol group, out of 14 secondary variables, five more variables (dizziness, alterations in sight, alterations in walking, agitation and alterations in speech) also showed significant differences due mainly to contrasts with the non-alcohol group. In none of these end points, could a statistically significant effect be found for the additional ingestion of energy drink or caffeine on the subjective feelings of alcohol intoxication. This within-subjects study does not confirm the presence of a "masking effect" when combining caffeine or energy drink with alcohol.
Holm, C; Thomsen, L L; Norgaard, A; Langhoff-Roos, J
2017-04-01
To evaluate the clinical efficacy of a single-dose intravenous infusion of iron isomaltoside compared with current treatment practice with oral iron measured by physical fatigue in women after postpartum haemorrhage. Single-centre, open-label, randomized controlled trial. Participants received intravenous iron (n = 97) or oral iron (n = 99), and completed the Multidimensional Fatigue Inventory and Edinburgh Postnatal Depression Scale, and haematological and iron parameters were measured. Primary outcome was the aggregated change in physical fatigue score from baseline to 12 weeks postpartum. The difference in physical fatigue score was -0·97 (95% CI: -1·65; -0·28, P = 0·006) in favour of intravenous iron, but did not meet the predefined difference of 1·8. Across visits, we found statistically significant differences in fatigue and depression scores, as well as in haematological and iron parameters, all in favour of intravenous iron. There were no serious adverse reactions. A single dose of intravenous iron was associated with a statistically significant reduction in aggregated physical fatigue within 12 weeks after postpartum haemorrhage compared to standard medical care with oral iron below the prespecified criteria of clinical superiority. As patient-reported outcomes improved significantly and intravenous iron resulted in a fast hematopoietic response without serious adverse reactions, intravenous iron may be a useful alternative after postpartum haemorrhage if oral iron is not absorbed or tolerated. © 2017 The Authors. Vox Sanguinis published by John Wiley & Sons Ltd on behalf of International Society of Blood Transfusion.
Singh, Nagendra Madan; Sathyaprabha, T. N.; Thirthalli, Jagadisha; Andrade, Chittaranjan
2018-01-01
Background: No electroconvulsive therapy (ECT) study on humans or in animal models has so far examined whether differently composed electrical stimuli exert different cardiac electrophysiological effects at constant electrical dose. The subject is important because cardiac electrophysiological changes may provide indirect information about ECT seizure quality as modulated by stimulus composition. Materials and Methods: Adult female Wistar rats (n = 20/group) received fixed, moderately suprathreshold (18 mC) electrical stimuli. This stimulus in each of eight groups was formed by varying pulse amplitude, pulse width, pulse frequency, and stimulus duration. The electrocardiogram was recorded, and time and frequency domain variables were examined in 30 s epochs in preictal (30 s before electroconvulsive shock [ECS]), early postictal (starting 15 s after stimulation), and late postictal (5 h after ECS) periods. Alpha for statistical significance was set at P < 0.01 to adjust for multiple hypothesis testing. Results: Cardiac electrophysiological indices in the eight groups did not differ significantly at baseline. At both early and late postictal time points, almost no analysis yielded statistically significant differences between groups for four time domain variables, including heart rate and standard deviation of R-R intervals, and for six frequency domain variables, including low-frequency power, high-frequency power, and total power. Conclusions: Cardiac electrophysiological measures may not be helpful to identify differences in seizure quality that are driven by differences in the composition of electrical stimuli at constant, moderately suprathreshold electrical dose. The generalization of this conclusion to threshold electrical doses and to human contexts requires a study. PMID:29736058
A double-blind comparative multicentre study of remoxipride and haloperidol in schizophrenia.
Lindström, L H; Wieselgren, I M; Struwe, G; Kristjansson, E; Akselson, S; Arthur, H; Andersen, T; Lindgren, S; Norman, O; Naimell, L
1990-01-01
In a double-blind multicentre study of parallel group design the efficacy and safety of remoxipride and haloperidol were compared in a total of 96 patients with acute episodes of schizophrenic or schizophreniform disorder according to DSM-III. There were 48 patients in each treatment group; 27 men and 21 women in the remoxipride group, 33 men and 15 women in the haloperidol group. The median duration of illness was 7 years in both groups. The mean daily dose was 437 mg for remoxipride and 10.6 mg for haloperidol during the last week of treatment. No statistically significant differences in total BPRS scores were found between remoxipride and haloperidol. The median total BPRS scores at the start of active treatment were 26 in the remoxipride and 27 in the haloperidol group; these were reduced to 16 and 12.5, respectively, at the last rating. According to Clinical Global Impression (CGI), 43% of patients in the remoxipride group and 68% of those in the haloperidol group improved much or very much during treatment. This difference was not statistically significant. Treatment-emergent extrapyramidal side effects such as akathisia, tremor, and rigidity occurred significantly more frequently in the haloperidol group; this group also made more frequent use of anticholinergic drugs. Neither of the trial drugs seriously affected laboratory or cardiovascular variables. It is concluded that remoxipride has an antipsychotic effect in a dose range of 150-600 mg per day comparable to that of haloperidol in doses up to 20 mg per day but with fewer extrapyramidal side effects.
Does Iterative Reconstruction Lower CT Radiation Dose: Evaluation of 15,000 Examinations
Noël, Peter B.; Renger, Bernhard; Fiebich, Martin; Münzel, Daniela; Fingerle, Alexander A.; Rummeny, Ernst J.; Dobritz, Martin
2013-01-01
Purpose Evaluation of 15,000 computed tomography (CT) examinations to investigate if iterative reconstruction (IR) reduces sustainably radiation exposure. Method and Materials Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. Results IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01). Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv), or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv) the dose reduction effect is significant(p*=0.01). On the contrary for unenhanced low-dose scans of the cranial (for example sinuses) the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv). Conclusion The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine. Our results illustrate that not only in studies with a limited number of patients but also in the clinical routine, IRs provide long-term dose saving. PMID:24303035
Does iterative reconstruction lower CT radiation dose: evaluation of 15,000 examinations.
Noël, Peter B; Renger, Bernhard; Fiebich, Martin; Münzel, Daniela; Fingerle, Alexander A; Rummeny, Ernst J; Dobritz, Martin
2013-01-01
Evaluation of 15,000 computed tomography (CT) examinations to investigate if iterative reconstruction (IR) reduces sustainably radiation exposure. Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01). Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv), or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv) the dose reduction effect is significant(p*=0.01). On the contrary for unenhanced low-dose scans of the cranial (for example sinuses) the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv). The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine. Our results illustrate that not only in studies with a limited number of patients but also in the clinical routine, IRs provide long-term dose saving.