Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H
2013-04-01
Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, Karsten, E-mail: sommerk@uni-mainz.de, E-mail: Schreiber-L@ukw.de; Bernat, Dominik; Schmidt, Regine
Purpose: The extent to which atherosclerotic plaques affect contrast agent (CA) transport in the coronary arteries and, hence, quantification of myocardial blood flow (MBF) using magnetic resonance imaging (MRI) is unclear. The purpose of this work was to evaluate the influence of plaque induced stenosis both on CA transport and on the accuracy of MBF quantification. Methods: Computational fluid dynamics simulations in a high-detailed realistic vascular model were employed to investigate CA bolus transport in the coronary arteries. The impact of atherosclerosis was analyzed by inserting various medium- to high-grade stenoses in the vascular model. The influence of stenosis morphologymore » was examined by varying the stenosis shapes but keeping the area reduction constant. Errors due to CA bolus transport were analyzed using the tracer-kinetic model MMID4. Results: Dispersion of the CA bolus was found in all models and for all outlets, but with a varying magnitude. The impact of stenosis was complex: while high-grade stenoses amplified dispersion, mild stenoses reduced the effect. Morphology was found to have a marked influence on dispersion for a small number of outlets in the post-stenotic region. Despite this marked influence on the concentration–time curves, MBF errors were less affected by stenosis. In total, MBF was underestimated by −7.9% to −44.9%. Conclusions: The presented results reveal that local hemodynamics in the coronary vasculature appears to have a direct impact on CA bolus dispersion. Inclusion of atherosclerotic plaques resulted in a complex alteration of this effect, with both degree of area reduction and stenosis morphology affecting the amount of dispersion. This strong influence of vascular transport effects impairs the accuracy of MRI-based MBF quantification techniques and, potentially, other bolus-based perfusion measurement techniques like computed tomography perfusion imaging.« less
Prediction of blood pressure and blood flow in stenosed renal arteries using CFD
NASA Astrophysics Data System (ADS)
Jhunjhunwala, Pooja; Padole, P. M.; Thombre, S. B.; Sane, Atul
2018-04-01
In the present work an attempt is made to develop a diagnostive tool for renal artery stenosis (RAS) which is inexpensive and in-vitro. To analyse the effects of increase in the degree of severity of stenosis on hypertension and blood flow, haemodynamic parameters are studied by performing numerical simulations. A total of 16 stenosed models with varying degree of stenosis severity from 0-97.11% are assessed numerically. Blood is modelled as a shear-thinning, non-Newtonian fluid using the Carreau model. Computational Fluid Dynamics (CFD) analysis is carried out to compute the values of flow parameters like maximum velocity and maximum pressure attained by blood due to stenosis under pulsatile flow. These values are further used to compute the increase in blood pressure and decrease in available blood flow to kidney. The computed available blood flow and secondary hypertension for varying extent of stenosis are mapped by curve fitting technique using MATLAB and a mathematical model is developed. Based on these mathematical models, a quantification tool is developed for tentative prediction of probable availability of blood flow to the kidney and severity of stenosis if secondary hypertension is known.
Smith, Lucy; Becker, Ingrid; Schroeder, Wolfgang; Hoelscher, Arnulf H; Haneder, Stefan; Maintz, David; Spiro, Judith Eva
2018-01-01
Purpose Anastomotic leakage is a major surgical complication following esophagectomy and gastric pull-up. Specific risk factors such as celiac trunk (TC) stenosis and high calcification score of the aorta have been identified, but no data are available on their relative prognostic values. This retrospective study aimed to compare and evaluate calcification score versus stenosis quantification with regards to prognostic impact on anastomotic leakage. Patients and methods Preoperative contrast-enhanced computed tomography scans of 164 consecutive patients with primary esophageal cancer were evaluated by two radiologists to apply a calcification score (0–3 scale) assessing the aorta, the celiac axis and the right and left postceliac arteries. Concurrently, the presence and degree of stenosis of TC and superior mesenteric artery were recorded for stenosis quantification. Results Anastomotic leakage was noted in 14/164 patients and 12/14 showed stenosis of TC (n=11). The presence of TC stenosis was found to have a significant impact on anastomotic healing (p=0.004). The odds ratio for the prediction of anastomotic leakage by the degree of stenosis was 1.04 (95% CI, 1.02–1.07). Ten of 14 patients had aortic calcification scores of 1 or 2, but calcification scores of the aorta, the celiac axis and the right and left postceliac arteries did not correlate with the corresponding TC stenosis values and showed no influence on patient outcome as defined by the occurrence of anastomotic insufficiency (p=0.565, 0.855, 0.518 and 1.000, respectively). Inter-reader reliability of computed tomography analysis and absolute agreement on calcium scoring was mostly over 90%. No significant differences in preoperative comorbidities and patient characteristics were found between those with and without anastomotic leakage. Conclusion Measurement of TC stenosis in preoperative contrast-enhanced computed tomography scans proved to be more reliable than calcification scores in predicting anastomotic leakage and should, therefore, be used in the risk assessment of patients undergoing esophagectomy and gastric pull-up. PMID:29713180
Leithner, Doris; Wichmann, Julian L; Mahmoudi, Scherwin; Martin, Simon S; Albrecht, Moritz H; Vogl, Thomas J; Scholtz, Jan-Erik
2018-06-01
To investigate the impact of low-tube-voltage 90-kVp acquisition combined with advanced modeled iterative reconstruction algorithm (Admire) on radiation exposure, image quality, artifacts, and assessment of stenosis in carotid and intracranial CT angiography (CTA). Dual-energy CTA studies of 43 patients performed on a third-generation 192-slice dual-source CT were retrospectively evaluated. Intraindividual comparison of 90-kVp and linearly blended 120-kVp equivalent image series (M_0.6, 60% 90-kVp, 40% Sn-150-kVp) was performed. Contrast-to-noise and signal-to-noise ratios of common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery were calculated. Qualitative image analysis included evaluation of artifacts and suitability for angiographical assessment at shoulder level, carotid bifurcation, siphon, and intracranial by three independent radiologists. Detection and quantification of carotid stenosis were performed. Radiation dose was expressed as dose-length product (DLP). Contrast-to-noise values of all arteries were significantly increased in 90-kVp compared to M_0.6 (p < 0.001). Suitability for angiographical evaluation was rated excellent with low artifacts for all levels in both image series. Both 90-kVp and M_0.6 showed excellent accordance for detection and grading of carotid stenosis with almost perfect interobserver agreement (carotid stenoses in 32 of 129 segments; intraclass correlation coefficient, 0.94). dose-length product was reduced by 40.3% in 90-kVp (110.6 ± 32.1 vs 185.4 ± 47.5 mGy·cm, p < 0.001). 90-kVp carotid and intracranial CTA with Admire provides increased quantitative and similarly good qualitative image quality, while reducing radiation exposure substantially compared to M_0.6. Diagnostic performance for arterial stenosis detection and quantification remained excellent. Advances in knowledge: 90-kVp carotid and intracranial CTA with an advanced iterative reconstruction algorithm results in excellent image quality and reduction of radiation exposure without limiting diagnostic performance.
Mukherjee, Somaditya; Jagadeeshaprasad, Mashanipalya G; Banerjee, Tanima; Ghosh, Sudip K; Biswas, Monodeep; Dutta, Santanu; Kulkarni, Mahesh J; Pattari, Sanjib; Bandyopadhyay, Arun
2014-01-01
Rheumatic fever in childhood is the most common cause of Mitral Stenosis in developing countries. The disease is characterized by damaged and deformed mitral valves predisposing them to scarring and narrowing (stenosis) that results in left atrial hypertrophy followed by heart failure. Presently, echocardiography is the main imaging technique used to diagnose Mitral Stenosis. Despite the high prevalence and increased morbidity, no biochemical indicators are available for prediction, diagnosis and management of the disease. Adopting a proteomic approach to study Rheumatic Mitral Stenosis may therefore throw some light in this direction. In our study, we undertook plasma proteomics of human subjects suffering from Rheumatic Mitral Stenosis (n = 6) and Control subjects (n = 6). Six plasma samples, three each from the control and patient groups were pooled and subjected to low abundance protein enrichment. Pooled plasma samples (crude and equalized) were then subjected to in-solution trypsin digestion separately. Digests were analyzed using nano LC-MS(E). Data was acquired with the Protein Lynx Global Server v2.5.2 software and searches made against reviewed Homo sapiens database (UniProtKB) for protein identification. Label-free protein quantification was performed in crude plasma only. A total of 130 proteins spanning 9-192 kDa were identified. Of these 83 proteins were common to both groups and 34 were differentially regulated. Functional annotation of overlapping and differential proteins revealed that more than 50% proteins are involved in inflammation and immune response. This was corroborated by findings from pathway analysis and histopathological studies on excised tissue sections of stenotic mitral valves. Verification of selected protein candidates by immunotechniques in crude plasma corroborated our findings from label-free protein quantification. We propose that this protein profile of blood plasma, or any of the individual proteins, could serve as a focal point for future mechanistic studies on Mitral Stenosis. In addition, some of the proteins associated with this disorder may be candidate biomarkers for disease diagnosis and prognosis. Our findings might help to enrich existing knowledge on the molecular mechanisms involved in Mitral Stenosis and improve the current diagnostic tools in the long run.
Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T
2013-12-01
Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.
Voelker, W; Reul, H; Nienhaus, G; Stelzer, T; Schmitz, B; Steegers, A; Karsch, K R
1995-02-15
Valvular resistance and stroke work loss have been proposed as alternative measures of stenotic valvular lesions that may be less flow dependent and, thus, superior over valve area calculations for the quantification of aortic stenosis. The present in vitro study was designed to compare the impacts of valvular resistance, stroke work loss, and Gorlin valve area as hemodynamic indexes of aortic stenosis. In a pulsatile aortic flow model, rigid stenotic orifices in varying sizes (0.5, 1.0, 1.5 and 2.0 cm2) and geometry were studied under different hemodynamic conditions. Ventricular and aortic pressures were measured to determine the mean systolic ventricular pressure (LVSPm) and the transstenotic pressure gradient (delta Pm). Transvalvular flow (Fm) was assessed with an electromagnetic flowmeter. Valvular resistance [VR = 1333.(delta Pm/Fm)] and stroke work loss [SWL = 100.(delta Pm/LVSPm)] were calculated and compared with aortic valve area [AVA = Fm/(50 square root of delta Pm)]. The measurements were performed for a large range of transvalvular flows. At low-flow states, flow augmentation (100-->200 mL/s) increased calculated valvular resistance between 21% (2.0 cm2 orifice) and 66% (0.5-cm2 orifice). Stroke work loss demonstrated an increase from 43% (2.0 cm2) to 100% (1.0 cm2). In contrast, Gorlin valve area revealed only a moderate change from 29% (2.0 cm2) to 5% (0.5 cm2). At physiological flow rates, increase in transvalvular flow (200-->300 mL/s) did not alter calculated Gorlin valve area, whereas valvular resistance and stroke work loss demonstrated a continuing increase. Our experimental results were adopted to interpret the results of three clinical studies in aortic stenosis. The flow-dependent increase of Gorlin valve area, which was found in the cited clinical studies, can be elucidated as true further opening of the stenotic valve but not as a calculation error due to the Gorlin formula. Within the physiological range of flow, calculated aortic valve area was less dependent on hemodynamic conditions than were valvular resistance and stroke work loss, which varied as a function of flow. Thus, for the assessment of the severity of aortic stenosis, the Gorlin valve area is superior over valvular resistance and stroke work loss, which must be indexed for flow to adequately quantify the hemodynamic severity of the obstruction.
Quantification of single-kidney glomerular filtration rate with electron-beam computed tomography
NASA Astrophysics Data System (ADS)
Lerman, Lilach O.; Ritman, Erik L.; Pelaez, Laura I.; Sheedy, Patrick F., II; Krier, James D.
2000-04-01
The ability to accurately and noninvasively quantify single- kidney GFR could be invaluable for assessment of renal function. We developed a model that enables this measurement with EBCT. To examine the reliability of this method, EBCT renal flow and volume studies after contrast media administration were performed in pigs with unilateral renal artery stenosis (Group 1), controls (Group 2), and simultaneously with inulin clearance (Group 3). Renal flow curves, obtained from the bilateral renal cortex and medulla, depicted transit of the contrast through the vascular and tubular compartments, and were fitted using extended gamma- variate functions. Renal blood flow was calculated as the sum of products of cortical and medullary perfusions and volumes. Normalized GFR (mL/min/cc) was calculated using the rate (maximal slope) of proximal tubular contrast accumulation, and EBCT-GFR as normalized GFR* cortical volume. In Group 1, the decreased GFR of the stenotic kidney correlated well with its decreased volume and RBF, and with the degree of stenosis (r equals -0.99). In Group 3, EBCT-GFR correlated well with inulin clearance (slope 1.1, r equals 0.81). This novel approach can be very useful for quantification of concurrent regional hemodynamics and function in the intact kidneys, in a manner potentially applicable to humans.
Fang, Hui; Song, Bo; Cheng, Bo; Wong, Ka Sing; Xu, Yu Ming; Ho, Stella Sin Yee; Chen, Xiang Yan
2016-03-18
Collateral pathways are important in maintaining adequate cerebral blood flow in patients with carotid stenosis. We aimed to evaluate the hemodynamic patterns in relation to carotid stenosis in acute stroke patients. Consecutive 586 stroke patients in a hospital based cohort were included in the present study. Carotid duplex was performed to identify patients with absolute minimal diameter reductions of 50% or greater in their internal carotid arteries (ICAs). Color velocity imaging quantification ultrasound (CVIQ) was used to measure extracranial arterial blood flow volume (BFV) in bilateral common carotid arteries (CCAs) and bilateral vertebral arteries (VAs). The absolute values of BFV and the ratios were compared between patients with and without ICA stenosis. Among 586 acute ischemic stroke patients (mean age: 67.5 ± 12.4y), ICA stenosis was detected in 112 patients (19.1%), including unilateral ICA stenosis in 81 patients (13.8%) and bilateral ICA stenosis in 31 patients (5.3%). Among patients with unilateral ICA stenosis, the BFV in contralateral CCA was significantly higher than that in ipsilateral CCA (325.5 ± 99.8 mL/min vs. 242.2 ± 112.2 mL/min, P < 0.001). Among patients with bilateral ICA stenosis, the sum of BFV in bilateral VAs accounted for 22% of the whole cerebral blood flow, which was significantly higher than that in those without ICA stenosis (14.8%, P < 0.001) or with unilateral ICA stenosis (16.9%, P = 0.007). In patients with unilateral carotid stenosis, contralateral carotid blood flow increases to compensate decreased blood flow, while posterior circulation may compensate for the decreased brain perfusion in those with bilateral carotid stenosis.
NASA Astrophysics Data System (ADS)
Richards, Taylor; Sturgeon, Gregory M.; Ramirez-Giraldo, Juan Carlos; Rubin, Geoffrey; Segars, Paul; Samei, Ehsan
2017-03-01
The purpose of this study was to quantify the accuracy of coronary computed tomography angiography (CTA) stenosis measurements using newly developed physical coronary plaque models attached to a base dynamic cardiac phantom (Shelley Medical DHP-01). Coronary plaque models (5 mm diameter, 50% stenosis, and 32 mm long) were designed and 3D-printed with tissue equivalent materials (calcified plaque with iodine enhanced lumen). Realistic cardiac motion was achieved by fitting known cardiac motion vectors to left ventricle volume-time curves to create synchronized heart motion profiles executed by the base cardiac phantom. Realistic coronary CTA acquisition was accomplished by synthesizing corresponding ECG waveforms for gating and reconstruction purposes. All scans were acquired using a retrospective gating technique on a dual-source CT system (Siemens SOMATOM FLASH) with 75ms temporal resolution. Multi-planar reformatted images were reconstructed along vessel centerlines and the enhanced lumens were manually segmented by 5 independent operators. On average, the stenosis measurement accuracy was 0.9% positive bias for the motion free condition (0 bpm). The measurement accuracy monotonically decreased to 18.5% negative bias at 90 bpm. Contrast-tonoise (CNR), vessel circularity, and segmentation conformity also decreased monotonically with increasing heart rate. These results demonstrate successful implementation of the base cardiac phantom with 3D-printed coronary plaque models, adjustable motion profiles, and coordinated ECG waveforms. They further show the utility of the model to ascertain metrics of coronary CT accuracy and image quality under a variety of plaque, motion, and acquisition conditions.
[Can the degree of renal artery stenosis be automatically quantified?].
Cherrak, I; Jaulent, M C; Azizi, M; Plouin, P F; Degoulet, P; Chatellier, G
2000-08-01
The objective of the reported study is to validate a computer system, QUASAR, dedicated to the quantification of renal artery stenoses. This system estimates automatically the reference diameter and calculates the minimum diameter to compute a degree of stenosis. A hundred and eighty images of atheromatous stenoses between 10% and 80% were collected from two French independent protocols. For the 49 images of the EMMA protocol, the results from QUASAR were compared with the visual estimation of an initial investigator and with the results from a reference method based on a panel of fixe experienced experts. For the 131 images of the ASTARTE protocol, the results from QUASAR were compared with those from a semi-automatic quantification system and with those from a system based on densitometric analysis. The present work validates QUASAR in a population of narrow atheromatous stenoses (> 50%). In the context of the EMMA protocol, QUASAR is not significantly different from the mean of the fixe experts. It is unbiased and more precise than the estimation of a single investigator. In the context of the ASTARTE protocol, there is no significant difference between the three methods for the stenoses higher than 50%, however, globally, QUASAR surestimates significantly (up to 10%) the degree of stenosis.
Uchihashi, Y; Hosoda, K; Zimine, I; Fujita, A; Fujii, M; Sugimura, K; Kohmura, E
2011-09-01
Arterial spin-labeling is an emerging technique for noninvasive measurement of cerebral perfusion, but concerns remain regarding the reliability of CBF quantification and clinical applications. Recently, an ASL implementation called QUASAR was proposed, and it was shown to have good reproducibility of CBF assessment in healthy volunteers. This study aimed to determine the utility of QUASAR for CBF assessment in patients with cerebrovascular diseases. Twenty patients with carotid stenosis underwent CBF quantification by ASL (QUASAR) within 3 days of performance of (123)I-iodoamphetamine-SPECT. CVR to acetazolamide also was assessed by ASL and SPECT. In surgically treated patients, the respective scans before and after the procedures were compared. Regional CBF and CVR values measured by ASL were significantly correlated and agreed with those measured by SPECT (r(s) = 0.92 and 0.88, respectively). A Bland-Altman plot demonstrated good agreement between 2 methods in terms of CBF quantification. Furthermore, ASL could detect pathologic states such as hypoperfusion, impaired vasoreactivity, and postoperative hyperperfusion, equivalent to SPECT. However, ASL tended to overestimate CBF values especially in high-perfusion regions. ASL perfusion MR imaging is clinically applicable and can be an alternative method for CBF assessment in patients with cerebrovascular diseases.
Ha, Hojin; Lantz, Jonas; Ziegler, Magnus; Casas, Belen; Karlsson, Matts; Dyverfeldt, Petter; Ebbers, Tino
2017-01-01
The pressure drop across a stenotic vessel is an important parameter in medicine, providing a commonly used and intuitive metric for evaluating the severity of the stenosis. However, non-invasive estimation of the pressure drop under pathological conditions has remained difficult. This study demonstrates a novel method to quantify the irreversible pressure drop across a stenosis using 4D Flow MRI by calculating the total turbulence production of the flow. Simulation MRI acquisitions showed that the energy lost to turbulence production can be accurately quantified with 4D Flow MRI within a range of practical spatial resolutions (1–3 mm; regression slope = 0.91, R2 = 0.96). The quantification of the turbulence production was not substantially influenced by the signal-to-noise ratio (SNR), resulting in less than 2% mean bias at SNR > 10. Pressure drop estimation based on turbulence production robustly predicted the irreversible pressure drop, regardless of the stenosis severity and post-stenosis dilatation (regression slope = 0.956, R2 = 0.96). In vitro validation of the technique in a 75% stenosis channel confirmed that pressure drop prediction based on the turbulence production agreed with the measured pressure drop (regression slope = 1.15, R2 = 0.999, Bland-Altman agreement = 0.75 ± 3.93 mmHg). PMID:28425452
Celi, Simona; Berti, Sergio
2014-10-01
Optical coherence tomography (OCT) is a catheter-based medical imaging technique that produces cross-sectional images of blood vessels. This technique is particularly useful for studying coronary atherosclerosis. In this paper, we present a new framework that allows a segmentation and quantification of OCT images of coronary arteries to define the plaque type and stenosis grading. These analyses are usually carried out on-line on the OCT-workstation where measuring is mainly operator-dependent and mouse-based. The aim of this program is to simplify and improve the processing of OCT images for morphometric investigations and to present a fast procedure to obtain 3D geometrical models that can also be used for external purposes such as for finite element simulations. The main phases of our toolbox are the lumen segmentation and the identification of the main tissues in the artery wall. We validated the proposed method with identification and segmentation manually performed by expert OCT readers. The method was evaluated on ten datasets from clinical routine and the validation was performed on 210 images randomly extracted from the pullbacks. Our results show that automated segmentation of the vessel and of the tissue components are possible off-line with a precision that is comparable to manual segmentation for the tissue component and to the proprietary-OCT-console for the lumen segmentation. Several OCT sections have been processed to provide clinical outcome. Copyright © 2014 Elsevier B.V. All rights reserved.
Maximal Aortic Valve Cusp Separation and Severity of Aortic Stenosis
Dilu, VP; George, Raju
2017-01-01
Introduction An integrated approach that incorporates two dimensional, M mode and Doppler echocardiographic evaluation has become the standard means for accurate quantification of severity of valvular aortic stenosis. Maximal separation of the aortic valve cusps during systole has been shown to correlate well with the severity of aortic stenosis measured by other echocardiographic parameters. Aim To study the correlation between Maximal Aortic valve Cusp Separation (MACS) and severity of aortic valve stenosis and to find cut-off values of MACS for detecting severe and mild aortic stenosis. Materials and Methods In the present prospective observational study, we have compared the accuracy of MACS distance and the aortic valve area calculated by continuity equation in 59 patients with varying degrees of aortic valve stenosis. Aortic leaflet separation in M mode was identified as the distance between the inner edges of the tips of these structures at mid systole in the parasternal long axis view. Cuspal separation was also measured in 2D echocardiography from the parasternal long axis view and the average of the two values was taken as the MACS. Patients were grouped into mild, moderate and severe aortic stenosis based on the aortic valve area calculated by continuity equation. The resultant data regarding maximal leaflet separation on cross-sectional echocardiogram was then subjected to linear regression analysis in regard to correlation with the peak transvalvular aortic gradient as well as the calculated aortic valve area. A cut-off value for each group was derived using ROC curve. Results There was a strong correlation between MACS and aortic valve area measured by continuity equation and the peak and mean transvalvular aortic gradients. Mean MACS was 6.89 mm in severe aortic stenosis, 9.97 mm in moderate aortic stenosis and 12.36 mm in mild aortic stenosis. MACS below 8.25 mm reliably predicted severe aortic stenosis, with high sensitivity, specificity and positive predictive value. MACS above 11.25 mm practically ruled out significant aortic stenosis. Conclusion Measurement of MACS is a simple echocardio-graphic method to assess the severity of valvular aortic stenosis, with high sensitivity and specificity. MACS can be extremely useful in two clinical situations as a simple screening tool for assessment of stenosis severity and also helps in decision making non invasively when there is discordance between the other echocardiographic parameters of severity of aortic stenosis. PMID:28764221
Fuchs, Tobias A; Fiechter, Michael; Gebhard, Cathérine; Stehli, Julia; Ghadri, Jelena R; Kazakauskaite, Egle; Herzog, Bernhard A; Husmann, Lars; Gaemperli, Oliver; Kaufmann, Philipp A
2013-03-01
To assess the impact of adaptive statistical iterative reconstruction (ASIR) on coronary plaque volume and composition analysis as well as on stenosis quantification in high definition coronary computed tomography angiography (CCTA). We included 50 plaques in 29 consecutive patients who were referred for the assessment of known or suspected coronary artery disease (CAD) with contrast-enhanced CCTA on a 64-slice high definition CT scanner (Discovery HD 750, GE Healthcare). CCTA scans were reconstructed with standard filtered back projection (FBP) with no ASIR (0 %) or with increasing contributions of ASIR, i.e. 20, 40, 60, 80 and 100 % (no FBP). Plaque analysis (volume, components and stenosis degree) was performed using a previously validated automated software. Mean values for minimal diameter and minimal area as well as degree of stenosis did not change significantly using different ASIR reconstructions. There was virtually no impact of reconstruction algorithms on mean plaque volume or plaque composition (e.g. soft, intermediate and calcified component). However, with increasing ASIR contribution, the percentage of plaque volume component between 401 and 500 HU decreased significantly (p < 0.05). Modern image reconstruction algorithms such as ASIR, which has been developed for noise reduction in latest high resolution CCTA scans, can be used reliably without interfering with the plaque analysis and stenosis severity assessment.
Flow characteristics around a deformable stenosis under pulsatile flow condition
NASA Astrophysics Data System (ADS)
Choi, Woorak; Park, Jun Hong; Byeon, Hyeokjun; Lee, Sang Joon
2018-01-01
A specific portion of a vulnerable stenosis is deformed periodically under a pulsatile blood flow condition. Detailed analysis of such deformable stenosis is important because stenotic deformation can increase the likelihood of rupture, which may lead to sudden cardiac death or stroke. Various diagnostic indices have been developed for a nondeformable stenosis by using flow characteristics and resultant pressure drop across the stenosis. However, the effects of the stenotic deformation on the flow characteristics remain poorly understood. In this study, the flows around a deformable stenosis model and two different rigid stenosis models were investigated under a pulsatile flow condition. Particle image velocimetry was employed to measure flow structures around the three stenosis models. The deformable stenosis model was deformed to achieve high geometrical slope and height when the flow rate was increased. The deformation of the stenotic shape enhanced jet deflection toward the opposite vessel wall of the stenosis. The jet deflection in the deformable model increased the rate of jet velocity and turbulent kinetic energy (TKE) production as compared with those in the rigid models. The effect of stenotic deformation on the pulsating waveform related with the pressure drop was analyzed using the TKE production rate. The deformable stenosis model exhibited a phase delay of the peak point in the waveform. These results revealed the potential use of pressure drop waveform as a diagnostic index for deformable stenosis.
Joshi, Subodh B; Okabe, Teruo; Roswell, Robert O; Weissman, Gaby; Lopez, Cristian F; Lindsay, Joseph; Pichard, Augusto D; Weissman, Neil J; Waksman, Ron; Weigold, Wm Guy
2009-10-15
Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.
Papanastasiou, Giorgos; Williams, Michelle C; Dweck, Marc R; Alam, Shirjel; Cooper, Annette; Mirsadraee, Saeed; Newby, David E; Semple, Scott I
2016-09-13
Mathematical modeling of perfusion cardiovascular magnetic resonance (CMR) data allows absolute quantification of myocardial blood flow and can potentially improve the diagnosis and prognostication of obstructive coronary artery disease (CAD), against the current clinical standard of visual assessments. This study compares the diagnostic performance of distributed parameter modeling (DP) against the standard Fermi model, for the detection of obstructive CAD, in per vessel against per patient analysis. A pilot cohort of 28 subjects (24 included in the final analysis) with known or suspected CAD underwent adenosine stress-rest perfusion CMR at 3T. Data were analysed using Fermi and DP modeling against invasive coronary angiography and fractional flow reserve, acquired in all subjects. Obstructive CAD was defined as luminal stenosis of ≥70 % alone, or luminal stenosis ≥50 % and fractional flow reserve ≤0.80. On ROC analysis, DP modeling outperformed the standard Fermi model, in per vessel and per patient analysis. In per patient analysis, DP modeling-derived myocardial blood flow at stress demonstrated the highest sensitivity and specificity (0.96, 0.92) in detecting obstructive CAD, against Fermi modeling (0.78, 0.88) and visual assessments (0.79, 0.88), respectively. DP modeling demonstrated consistently increased diagnostic performance against Fermi modeling and showed that it may have merit for stratifying patients with at least one vessel with obstructive CAD. Clinicaltrials.gov NCT01368237 Registered 6 of June 2011. URL: https://clinicaltrials.gov/ct2/show/NCT01368237.
McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.
2010-01-01
Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731
Naehle, Claas P; Steinberg, Verena A; Schild, Hans; Mommertz, Gottfried
2015-05-01
Noninvasive measurement of peripheral muscle microperfusion could potentially improve diagnosis, management, and treatment of peripheral arterial disease (PAD) and thus improve patient care. Contrast-enhanced ultrasound (CEUS) as a noninvasive diagnostic tool allows quantification of muscle perfusion. Increasing data on bolus technique CEUS reflecting microperfusion are becoming available, but only limited data on steady-state CEUS for assessment of muscle microperfusion are available. Therefore, the aim of this study was to evaluate steady-state CEUS for assessment of peripheral muscle microperfusion in a PAD animal model. In a porcine animal model, peripheral muscle microperfusion was quantified by steady-state CEUS replenishment kinetics (mean transit time [mTT] and wash-in rate [WiR]) of the biceps femoris muscle during intravenous steady-state infusion of INN-sulfur hexafluoride (SonoVue; Bracco, Geneva, Switzerland). In addition, macroperfusion was quantified at the external femoral artery with a Doppler flow probe. Peripheral muscle microperfusion and Doppler flow measurements were performed bilaterally at rest and under adenosine stress (70 μg/kg body weight) before and after unilateral creation of a moderate external iliac artery stenosis. All measurements could be performed completely in 10 pigs. Compared with baseline measurements, peripheral muscle microperfusion decreased significantly during adenosine stress (rest vs adenosine stress: mTT, 7.8 ± 3.3 vs 21.2 ± 17.8 s, P = .0006; WiR, 58.4 ± 38.1 vs 25.3 ± 15.6 arbitrary units [a.u.]/s, P < .0001; Doppler flow, 122.3 ± 31.4 vs 83.6 ± 28.1 mL/min, P = .0067) and after stenosis creation (no stenosis vs stenosis: mTT, 8.1 ± 3.1 vs 29.2 ± 18.0 s, P = .0469; WiR, 53.0 ± 22.7 vs 13.6 ± 8.4 a.u./s, P = .0156; Doppler flow, 124.2 ± 41.8 vs 65.9 ± 40.0 mL/min, P = .0313). After stenosis creation, adenosine stress led to a further significant decrease of peripheral muscle microperfusion but had no effect on macroperfusion (mTT, 29.2 ± 18.0 vs 56.3 ± 38.7 s, P = .0078; WiR, 13.6 ± 8.4 vs 6.0 ± 4.1 a.u./s, P = .0078; Doppler flow, 65.9 ± 40.0 vs 79.2 ± 29.6 mL/min, P = .8125). Receiver operating characteristic curves for the presence of inflow stenosis showed an excellent area under the curve of 0.93 for mTT at rest and 0.86 for Doppler flow. Peripheral muscle microperfusion measurement by steady-state CEUS with replenishment kinetics is feasible and allows detection of muscle microperfusion changes caused by vasodilative stress alone or in combination with a moderate inflow stenosis. Steady-state CEUS offers superior diagnostic performance compared with Doppler flow measurements. Therefore, steady-state CEUS may prove to be a useful tool in diagnosis of PAD and for evaluation of new therapies. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Serena, Joaquín; Segura, Tomás; Roquer, Jaume; García-Gil, María; Castillo, José
2015-03-11
About 20% of patients with a first ischaemic stroke will experience a new vascular event within the first year. The atherosclerotic burden, an indicator of the extension of atherosclerosis in a patient, has been associated with the risk of new cardiovascular events in the general population. However, no predictive models reliably identify groups at a high risk of recurrence. The ARTICO study prospectively analysed the predictive value for the risk of recurrence of specific atherosclerotic markers. The multicentre ARTICO study included 620 consecutive independent patients older than 60 years suffering from a first non-cardioembolic stroke. We analysed classical stroke risk factors; duplex study of supraaortic trunk including intima-media thickness (IMT) measurement; quantification of internal carotid (ICA) stenosis; number, morphology and surface characteristics of carotid plaques; ankle brachial index (ABI); and the presence of microalbuminuria. Patients were followed up at 6 and 12 months after inclusion. The primary end-point was death or major cardiovascular events. Any vascular event or death at 12 months occurred in 78 (13.8%) patients. In 40 (7.1%) of these the vascular event was a stroke recurrence. Weight, history of diabetes mellitus, history of symptomatic PAD, ABI <0.9 and significant ICA stenosis (>50%) were associated with a higher risk of vascular events on follow-up in the bivariate analysis. In the final Cox regression analysis, body mass index (BMI), systolic blood pressure, history of diabetes mellitus, symptomatic PAD (HR, 2.76; 95% CI, 1.10-6.95; p=0.03), and particularly patients with both ICA stenosis >50% and PAD (HR 4.52; 95% CI, 2.14-9.53; p<0.001) were independently associated with an increased risk of vascular events. Neither isolated ICA stenosis >50% nor isolated abnormal ABI remained associated with an increased risk of recurrence in comparison with the whole population. Symptomatic PAD identifies a high risk group of vascular recurrence after a first non-cardioembolic stroke. The associated increased risk was particularly high in patients with both ICA stenosis and either symptomatic or asymptomatic PAD. Neither asymptomatic PAD alone nor isolated ICA stenosis >50% were associated with an increased risk of recurrence in this particularly high-risk group of non-cardioembolic stroke.
An LBM based model for initial stenosis development in the carotid artery
NASA Astrophysics Data System (ADS)
Stamou, A. C.; Buick, J. M.
2016-05-01
A numerical scheme is proposed to simulate the early stages of stenosis development based on the properties of blood flow in the carotid artery, computed using the lattice Boltzmann method. The model is developed on the premise, supported by evidence from the literature, that the stenosis develops in regions of low velocity and low wall shear stress. The model is based on two spatial parameters which relate to the extent to which the stenosis can grow in each development phase. Simulations of stenosis development are presented for a range of the spacial parameters to determine suitable ranges for their application. Flow fields are also presented which indicate that the stenosis is developing in a realistic manner, providing evidence that stenosis development is indeed influenced by the low shear stress, rather than occurring in such areas coincidentally.
Voros, Szilard; Maurovich-Horvat, Pal; Marvasty, Idean B; Bansal, Aruna T; Barnes, Michael R; Vazquez, Gustavo; Murray, Sarah S; Voros, Viktor; Merkely, Bela; Brown, Bradley O; Warnick, G Russell
2014-01-01
Complex biological networks of atherosclerosis are largely unknown. The main objective of the Genetic Loci and the Burden of Atherosclerotic Lesions study is to assemble comprehensive biological networks of atherosclerosis using advanced cardiovascular imaging for phenotyping, a panomic approach to identify underlying genomic, proteomic, metabolomic, and lipidomic underpinnings, analyzed by systems biology-driven bioinformatics. By design, this is a hypothesis-free unbiased discovery study collecting a large number of biologically related factors to examine biological associations between genomic, proteomic, metabolomic, lipidomic, and phenotypic factors of atherosclerosis. The Genetic Loci and the Burden of Atherosclerotic Lesions study (NCT01738828) is a prospective, multicenter, international observational study of atherosclerotic coronary artery disease. Approximately 7500 patients are enrolled and undergo non-contrast-enhanced coronary calcium scanning by CT for the detection and quantification of coronary artery calcium, as well as coronary artery CT angiography for the detection and quantification of plaque, stenosis, and overall coronary artery disease burden. In addition, patients undergo whole genome sequencing, DNA methylation, whole blood-based transcriptome sequencing, unbiased proteomics based on mass spectrometry, as well as metabolomics and lipidomics on a mass spectrometry platform. The study is analyzed in 3 subsequent phases, and each phase consists of a discovery cohort and an independent validation cohort. For the primary analysis, the primary phenotype will be the presence of any atherosclerotic plaque, as detected by cardiac CT. Additional phenotypic analyses will include per patient maximal luminal stenosis defined as 50% and 70% diameter stenosis. Single-omic and multi-omic associations will be examined for each phenotype; putative biomarkers will be assessed for association, calibration, discrimination, and reclassification. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
A canine model of tracheal stenosis induced by cuffed endotracheal intubation
Su, Zhuquan; Li, Shiyue; Zhou, Ziqing; Chen, Xiaobo; Gu, Yingying; Chen, Yu; Zhong, Changhao; Zhong, Minglu; Zhong, Nanshan
2017-01-01
Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuff pressures of 100 to 200 mmHg for 24 hr. The status of tracheal wall was evaluated by bronchoscopic and histological examinations. The model was successfully established by cuffed endotracheal intubation using an 8.0 mm tube and an intra-cuff pressure of 200 mmHg for 24 hr. When the intra-cuff pressures were kept constant, a larger sized tube would induce a larger tracheal wall pressure and more severe injury to the tracheal wall. The degree of tracheal stenosis ranged from 78% to 91% at 2 weeks postextubation. Histological examination demonstrated submucosal infiltration of inflammatory cells, hyperplasia of granulation tissue and collapse of tracheal cartilage. In summary, a novel animal model of tracheal stenosis was established by cuffed endotracheal intubation, whose histopathological feathers are similar to those of clinical cases of postintubation tracheal stenosis. Excessive cuff pressure and over-sized tube are the risk factors for postintubation tracheal stenosis. PMID:28349955
Bertram, C D; Heil, M
2017-01-01
An existing axisymmetric fluid/structure-interaction (FSI) model of the spinal cord, pia mater, subarachnoid space, and dura mater in the presence of syringomyelia and subarachnoid-space stenosis was modified to include porous solids. This allowed investigation of a hypothesis for syrinx fluid ingress from cerebrospinal fluid (CSF). Gross model deformation was unchanged by the addition of porosity, but pressure oscillated more in the syrinx and the subarachnoid space below the stenosis. The poroelastic model still exhibited elevated mean pressure in the subarachnoid space below the stenosis and in the syrinx. With realistic cord permeability, there was slight oscillatory shunt flow bypassing the stenosis via the porous tissue over the syrinx. Weak steady streaming flow occurred in a circuit involving craniocaudal flow through the stenosis and back via the syrinx. Mean syrinx volume was scarcely altered when the adjacent stenosis bisected the syrinx, but increased slightly when the syrinx was predominantly located caudal to the stenosis. The fluid content of the tissues over the syrinx oscillated, absorbing most of the radial flow seeping from the subarachnoid space so that it did not reach the syrinx. To a lesser extent, this cyclic swelling in a boundary layer of cord tissue just below the pia occurred all along the cord, representing a mechanism for exchange of interstitial fluid (ISF) and cerebrospinal fluid which could explain recent tracer findings without invoking perivascular conduits. The model demonstrates that syrinx volume increase is possible when there is subarachnoid-space stenosis and the cord and pia are permeable.
Kefayati, Sarah; Holdsworth, David W; Poepping, Tamie L
2014-01-03
Clinical decision-making for the treatment of patients with diseased carotid artery is mainly based on the severity of the stenosis. However, stenosis severity alone is not a sensitive indicator, and other local factors for the assessment of stroke risk are required. Flow disturbance is of particular interest due to its proven association with increased thromboembolic activities. The objective of this study was to investigate the level of turbulence intensity (TI) with regards to certain geometrical features of the plaque - namely stenosis severity, eccentricity, and ulceration. A family of eight carotid-artery bifurcation models was examined using particle image velocimetry. Results showed a marked difference in turbulence intensity among these models; increasing degree of stenosis severity resulted in increased turbulence intensity, going from 0.12 m/s for mild stenosis to 0.37 m/s for severe stenosis (with concentric geometry). Moreover, independent of stenosis severity, eccentricity led to further elevations in turbulence intensity, increasing TI by 0.05-0.10 m/s over the counterpart concentric plaque. The presence of ulceration (in a 50% eccentric plaque) produced a larger portion of moderate turbulence intensity (~0.10 m/s) compared to the non-ulcerated model, more proximal to the bifurcation apex in the post-stenotic recirculation zone. The effect of plaque eccentricity and ulceration in enhancing the downstream turbulence has potential clinical implications for a more sensitive assessment of stroke risk beyond stenosis severity alone. © 2013 Elsevier Ltd. All rights reserved.
Drag reducing polymers improve coronary flow reserve through modulation of capillary resistance.
Pacella, John J; Kameneva, Marina V; Villanueva, Flordeliza S
2009-01-01
We have shown that drag-reducing polymers (DRP) reduce microvascular resistance and improve myocardial perfusion during coronary stenosis. We used myocardial contrast echocardiography (MCE) and mathematical modeling to define the DRP microvascular effects. A non-flow-limiting left anterior descending (LAD) stenosis was created in 8 dogs. Intramyocardial blood volume, RBC velocity and flow in the LAD and circumflex (CX) beds were obtained from MCE at baseline, and in hyperemia, stenosis, hyperemia + stenosis, and hyperemia + stenosis + DRP. Microvascular resistances were calculated from a lumped-parameter model. During stenosis + hyperemia, LAD bed microvascular resistance increased (p<0.015), and capillary volume (p<0.002) and red cell velocity (p<0.0004) decreased relative to baseline. With DRP, during stenosis and hyperemia, LAD bed microvascular resistance decreased (p<0.04); there was an increase in capillary volume (p<0.007), RBC velocity (p<0.006), and flow (p<0.05). Decreased model-computed capillary resistance accounted for the reduction in LAD bed resistance after DRP. We conclude that DRP improve flow reserve during coronary stenosis by modulating capillary resistance. Primary modification of the rheological properties of blood to affect capillary resistance is a novel approach for the treatment of acute coronary syndromes.
McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Herrero, Pilar; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie
2011-01-01
Background A comprehensive evaluation of myocardial ischemia requires measures of both oxygen supply and demand. Positron emission tomography (PET) is currently the gold standard for such evaluations, but its use is limited due to its ionizing radiation, limited availability, and high cost. A cardiac magnetic resonance imaging (MRI) method was developed for assessing myocardial oxygenation. The purpose of this study was to evaluate and validate this technique compared to PET during pharmacologic stress in a canine model of coronary artery stenosis. Methods and Results Twenty-one beagles and small mongrel dogs without coronary artery stenosis (controls), or with moderate to severe acute coronary artery stenosis underwent MRI and PET imaging at rest and during dipyridamole vasodilation or dobutamine stress to induce a wide range of changes in cardiac perfusion and oxygenation. MRI first-pass perfusion imaging was performed to quantify myocardial blood flow (MBF) and volume (MBV). The MRI blood-oxygen-level-dependent (BOLD) technique was used to determine the myocardial oxygen extraction fraction (OEF) during pharmacologic hyperemia. Myocardial oxygen consumption (MVO2) was determined by Fick’s law. In the same dogs, 15O-water and 11C-acetate were used to measure MBF and MVO2, respectively, by PET. Regional assessments were performed for both MR and PET. MRI data correlated nicely with PET values for MBF (R2 = 0.79, P < 0.001), MVO2 (R2 = 0.74, P < 0.001), and OEF (R2 = 0.66, P < 0.01). Conclusions Cardiac MRI methods may provide an alternative to radionuclide imaging in settings of myocardial ischemia. Our newly developed quantitative MRI oxygenation imaging technique may be a valuable non-invasive tool to directly evaluate myocardial energetics and efficiency. PMID:19933371
Study of normal, fibrous and calcified aortic valve tissue by Raman and reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Rodrigues, Kátia Calligaris; Munin, Egberto; Alves, Leandro P.; Silveira, Fabrício L.; Junior, Landulfo S.; De Lima, Carlos J.; Lázzaro, João C.; De Souza, Genivaldo C.; Piotto, José A. B.; Pacheco, Marcos T. T.; Zângaro, Renato A.
2007-02-01
Several studies have identified the degree of aortic valve calcification as a strong predictor both for the progression and outcome of aortic stenosis. In industrialized countries, aortic valve stenosis is most frequently caused by progressive calcification and degeneration of aortic cusps. However, there are no accurate methods to quantify the extent of aortic valve calcification. To provide a non-invasive alternative to biopsy, a range of optical methods have been investigated, including Raman and reflectance spectroscopy. A Raman spectrum can be used to access the molecular constitution of a particular tissue and classify it. Raman spectroscopy is largely used in the quantification and evaluation of human atherosclerosis, being a powerful technique for performing biochemical analysis without tissue removal. Nevertheless, increased thickness and disorganization of the collagen fibre network and extracellular matrix are known to affect the diffuse spectral reflectance of the tissue. A catheter with the "6 around 1" configuration, the central fiber transmit laser radiation to the sample and the scattered light is collected by the other six surrounding fibers, was used both for Raman and reflectance spectroscopy. A white light (krypton lamp, flashtube Model FX 1160 Perkin Elmer, USA) excitation was used for reflectance measurements. A Ti-sapphire (785nm, Spectra Physics, model 3900S, USA) laser, pumped by an argon laser (Spectra Physics, model Stabilite 2017, USA) was used as the near infrared Raman set up. Several ex-vivo spectra of aortic valve samples were analyzed. The results show a promising way to differentiate normal, fibrous and calcified tissue in aortic valve.
Should conventional angiography be the gold standard for carotid stenosis?
Zhang, Wayne W; Harris, Linda M; Dryjski, Maciej L
2006-12-01
To compare conventional angiography (CA) and rotational angiography (RA) to assess the degree of angiographically-measured stenosis versus cross-sectional area (CSA) stenosis in an in vitro carotid model. Various grades of stenosis were created by adhering different amounts of silicone rubber sealant onto the inner wall of clear, radiolucent tubes. Following 2- and 3-projection CA and 20-projection RA, the tubes were transected at the actual maximum stenosis. The cross-sectional areas were digitally photographed, and CSA stenosis was calculated using ImageJ planimeter software. The differences among CA, RA, and CSA stenosis measurements were compared statistically. There was no significant difference between RA and CSA stenosis measurements (p=0.46). Conventional angiography with 2 or 3 projections between 0 degrees and 90 degrees underestimated the severity of disease in 19 (63%) of 30 samples. The maximum stenosis percentage was significantly lower in CA versus RA (p<0.0001 in 2-projection, p<0.0003 in 3-projection) and in CA versus CSA stenosis (p<0.0004 in 2-projection, p<0.001 in 3-projection). The maximum stenosis percentages measured by RA were less than CSA stenosis in 5 (71.4%) of 7 tubes (p=NS) containing 50% to 69% stenoses. Eight tubes had mountain-shaped lesions, which was significantly overestimated by RA (11.5%+/-9.7%, p<0.012). CA with 2 or 3 projections significantly underestimates the maximum stenosis in an in vitro model. RA may overestimate disease in patients with mountain-shaped plaques and may underestimate disease if the stenosis is <70%. Our data suggest that CA should not be the gold standard for the qualification of carotid endarterectomy in asymptomatic patients, nor for vascular laboratory quality assurance analysis.
Musa, Tarique Al; Plein, Sven; Greenwood, John P
2016-06-01
Degenerative aortic stenosis (AS) is the most common valvular disease in the western world with a prevalence expected to double within the next 50 years. International guidelines advocate the use of cardiovascular magnetic resonance (CMR) as an investigative tool, both to guide diagnosis and to direct optimal treatment. CMR is the reference standard for quantifying both left and right ventricular volumes and mass, which is essential to assess the impact of AS upon global cardiac function. Given the ability to image any structure in any plane, CMR offers many other diagnostic strengths including full visualisation of valvular morphology, direct planimetry of orifice area, the quantification of stenotic jets and in particular, accurate quantification of valvular regurgitation. In addition, CMR permits reliable and accurate measurements of the aortic root and arch which can be fundamental to appropriate patient management. There is a growing evidence base to indicate tissue characterisation using CMR provides prognostic information, both in asymptomatic AS patients and those undergoing intervention. Furthermore, a number of current clinical trials will likely raise the importance of CMR in routine patient management. This article will focus on the incremental value of CMR in the assessment of severe AS and the insights it offers following valve replacement.
Effects of vascular structures on the pressure drop in stenotic coronary arteries
NASA Astrophysics Data System (ADS)
Kim, Jaerim; Choi, Haecheon; Kweon, Jihoon; Kim, Young-Hak; Yang, Dong Hyun; Kim, Namkug
2016-11-01
A stenosis, which is a narrowing of a blood vessel, of the coronary arteries restricts the flow to the heart and it may lead to sudden cardiac death. Therefore, the accurate determination of the severity of a stenosis is a critical issue. Due to the convenience of visual assessments, geometric parameters such as the diameter stenosis and area stenosis have been used, but the decision based on them sometimes under- or overestimates the functional severity of a stenosis, i.e., pressure drop. In this study, patient-specific models that have similar area stenosis but different pressure drops are considered, and their geometries are reconstructed from the coronary computed tomography angiography (CCTA). Both steady and pulsatile inflows are considered for the simulations. Comparison between two models that have a bifurcation right after a stenosis shows that the parent to daughter vessel angle results in different secondary flow patterns and wall shear stress distributions which affect the pressure downstream. Thus, the structural features of the lower and upper parts of a stenosis significantly affect the pressure drop. Supported by 20152020105600.
Hassani, Kamran; Navidbakhsh, Mahdi; Rostami, Mostafa
2007-01-01
Background The aortic aneurysm is a dilatation of the aortic wall which occurs in the saccular and fusiform types. The aortic aneurysms can rupture, if left untreated. The renal stenosis occurs when the flow of blood from the arteries leading to the kidneys is constricted by atherosclerotic plaque. This narrowing may lead to the renal failure. Previous works have shown that, modelling is a useful tool for understanding of cardiovascular system functioning and pathophysiology of the system. The present study is concerned with the modelling of aortic aneurysms and renal artery stenosis using the cardiovascular electronic system. Methods The geometrical models of the aortic aneurysms and renal artery stenosis, with different rates, were constructed based on the original anatomical data. The pressure drop of each section due to the aneurysms or stenosis was computed by means of computational fluid dynamics method. The compliance of each section with the aneurysms or stenosis is also calculated using the mathematical method. An electrical system representing the cardiovascular circulation was used to study the effects of these pressure drops and the compliance variations on this system. Results The results showed the decreasing of pressure along the aorta and renal arteries lengths, due to the aneurysms and stenosis, at the peak systole. The mathematical method demonstrated that compliances of the aorta sections and renal increased with the expansion rate of the aneurysms and stenosis. The results of the modelling, such as electrical pressure graphs, exhibited the features of the pathologies such as hypertension and were compared with the relevant experimental data. Conclusion We conclude from the study that the aortic aneurysms as well as renal artery stenosis may be the most important determinant of the arteries rupture and failure. Furthermore, these pathologies play important rules in increase of the cardiovascular pulse pressure which leads to the hypertension. PMID:17559685
A new CFD based non-invasive method for functional diagnosis of coronary stenosis.
Xie, Xinzhou; Zheng, Minwen; Wen, Didi; Li, Yabing; Xie, Songyun
2018-03-22
Accurate functional diagnosis of coronary stenosis is vital for decision making in coronary revascularization. With recent advances in computational fluid dynamics (CFD), fractional flow reserve (FFR) can be derived non-invasively from coronary computed tomography angiography images (FFR CT ) for functional measurement of stenosis. However, the accuracy of FFR CT is limited due to the approximate modeling approach of maximal hyperemia conditions. To overcome this problem, a new CFD based non-invasive method is proposed. Instead of modeling maximal hyperemia condition, a series of boundary conditions are specified and those simulated results are combined to provide a pressure-flow curve for a stenosis. Then, functional diagnosis of stenosis is assessed based on parameters derived from the obtained pressure-flow curve. The proposed method is applied to both idealized and patient-specific models, and validated with invasive FFR in six patients. Results show that additional hemodynamic information about the flow resistances of a stenosis is provided, which cannot be directly obtained from anatomy information. Parameters derived from the simulated pressure-flow curve show a linear and significant correlations with invasive FFR (r > 0.95, P < 0.05). The proposed method can assess flow resistances by the pressure-flow curve derived parameters without modeling of maximal hyperemia condition, which is a new promising approach for non-invasive functional assessment of coronary stenosis.
Construction and geometric stability of physiological flow rate wall-less stenosis phantoms.
Ramnarine, K V; Anderson, T; Hoskins, P R
2001-02-01
Wall-less flow phantoms are preferred for ultrasound (US) because tissue-mimicking material (TMM) with good acoustical properties can be made and cast to form anatomical models. The construction and geometrical stability of wall-less TMM flow phantoms is described using a novel method of sealing to prevent leakage of the blood-mimicking fluid (BMF). Wall-less stenosis flow models were constructed using a robust agar-based TMM and sealed using reticulated foam at the inlet and outlet tubes. There was no BMF leakage at the highest flow rate of 2.8 L/min in 0%, 35% and 57% diameter reduction stenoses models. Failure of the 75% stenosis model, due to TMM fracture, occurred at maximum flow rate of 2 L/min (mean velocity 10 m/s within the stenosis). No change of stenosis geometry was measured over 4 days. The construction is simple and effective and extends the possibility for high flow rate studies using robust TMM wall-less phantoms.
Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery.
Kamangar, Sarfaraz; Badruddin, Irfan Anjum; Ameer Ahamad, N; Soudagar, Manzoor Elahi M; Govindaraju, Kalimuthu; Nik-Ghazali, N; Salman Ahmed, N J; Yunus Khan, T M
2017-01-01
The current study investigates the effect of multi stenosis on the hemodynamic parameters such as wall pressure, velocity and wall shear stress in the realistic left coronary artery. Patients CT scan image data of normal and diseased left coronary artery was chosen for the reconstruction of 3D coronary artery models. The diseased 3D model of left coronary artery shows a narrowing of more than 70% and 80% of area stenosis (AS) at the left main stem (LMS) and left circumflex (LCX) respectively. The results show that the decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. The maximum pressure drop was noted across the 80% AS at the left circumflex branch. The recirculation zone was also observed immediate to the stenosis and highest wall shear stress was found across the 80% area stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding on the hemodynamics in realistic coronary artery.
Huo, Yunlong; Luo, Tong; Guccione, Julius M; Teague, Shawn D; Tan, Wenchang; Navia, José A; Kassab, Ghassan S
2013-01-01
It is well known that flow patterns at the anastomosis of coronary artery bypass graft (CABG) are complex and may affect the long-term patency. Various attempts at optimal designs of anastomosis have not improved long-term patency. Here, we hypothesize that mild anastomotic stenosis (area stenosis of about 40-60%) may be adaptive to enhance the hemodynamic conditions, which may contribute to slower progression of atherosclerosis. We further hypothesize that proximal/distal sites to the stenosis have converse changes that may be a risk factor for the diffuse expansion of atherosclerosis from the site of stenosis. Twelve (12) patient-specific models with various stenotic degrees were extracted from computed tomography images using a validated segmentation software package. A 3-D finite element model was used to compute flow patterns including wall shear stress (WSS) and its spatial and temporal gradients (WSS gradient, WSSG, and oscillatory shear index, OSI). The flow simulations showed that mild anastomotic stenosis significantly increased WSS (>15 dynes · cm(-2)) and decreased OSI (<0.02) to result in a more uniform distribution of hemodynamic parameters inside anastomosis albeit proximal/distal sites to the stenosis have a decrease of WSS (<4 dynes · cm(-2)). These findings have significant implications for graft adaptation and long-term patency.
Köppl, Tobias; Santin, Gabriele; Haasdonk, Bernard; Helmig, Rainer
2018-05-06
In this work, we consider two kinds of model reduction techniques to simulate blood flow through the largest systemic arteries, where a stenosis is located in a peripheral artery i.e. in an artery that is located far away from the heart. For our simulations we place the stenosis in one of the tibial arteries belonging to the right lower leg (right post tibial artery). The model reduction techniques that are used are on the one hand dimensionally reduced models (1-D and 0-D models, the so-called mixed-dimension model) and on the other hand surrogate models produced by kernel methods. Both methods are combined in such a way that the mixed-dimension models yield training data for the surrogate model, where the surrogate model is parametrised by the degree of narrowing of the peripheral stenosis. By means of a well-trained surrogate model, we show that simulation data can be reproduced with a satisfactory accuracy and that parameter optimisation or state estimation problems can be solved in a very efficient way. Furthermore it is demonstrated that a surrogate model enables us to present after a very short simulation time the impact of a varying degree of stenosis on blood flow, obtaining a speedup of several orders over the full model. This article is protected by copyright. All rights reserved.
Irradiation inhibits vascular anastomotic stenosis in a canine model.
Saito, Takeshi; Iguchi, Atsushi; Tabayashi, Koichi
2009-08-01
The graft patency rate after coronary artery bypass grafting (CABG) correlates with anastomotic stenosis. Intracoronary radiation therapy is effective for preventing restenosis after percutaneous coronary intervention (PCI). We postulated that intracoronary radiation therapy could prevent anastomotic stenosis and tested this hypothesis in an animal model. Femoral arteries and veins of beagle dogs were harvested, and composite arterioarterial and arteriovenous grafts were prepared. After external irradiation of the anastomotic sites, these composite grafts were transplanted into femoral arteries. Histomorphometric and immunohistological analyses of the anastomotic sites were performed. The study groups consisted of controls and animals exposed to 10 Gy, 20 Gy, and 30 Gy (n = 5, in each group). In the artery graft model, the ratio of negative remodeling was significantly increased in all groups exposed to >or=10 Gy. The ratio of neointimal hyperplasia was significantly decreased in all groups exposed to >or=10 Gy. Cell density of anti-alpha-actin antibody-positive cells and anti-proliferating cell nuclear antigen (PCNA) antibody-positive cells was highest in the adventitial layer, and the density decreased as the dosage increased. Experimental results were almost the same in the vein graft models as in the artery graft models. With double immunohistostaining, the anti-PCNA antibody-positive cells expressed alpha-actin. Irradiation can inhibit anastomotic stenosis in a canine model. Adventitia is a factor in the creation of stenosis, and irradiation appears to target the adventitia. We speculate that there might be a possible role for intracoronary irradiation in the future to prevent anastomotic stenosis.
Impact of MCA stenosis on the early outcome in acute ischemic stroke patients
Jeng, Jiann-Shing; Hsieh, Fang-I; Yeh, Hsu-Ling; Chen, Wei-Hung; Chiu, Hou-Chang; Tang, Sung-Chun; Liu, Chung-Hsiang; Lin, Huey-Juan; Hsu, Shih-Pin; Lo, Yuk-Keung; Chan, Lung; Chen, Chih-Hung; Lin, Ruey-Tay; Chen, Yu-Wei; Lee, Jiunn-Tay; Yeh, Chung-Hsin; Sun, Ming-Hui; Lai, Ta-Chang; Sun, Yu; Sun, Mu-Chien; Chen, Po-Lin; Chiang, Tsuey-Ru; Lin, Shinn-Kuang; Yip, Bak-Sau; Chen, Chin-I; Bai, Chi-Huey; Chen, Sien-Tsong; Chiou, Hung-Yi; Lien, Li-Ming; Hsu, Chung Y.
2017-01-01
Background Asians have higher frequency of intracranial arterial stenosis. The present study aimed to compare the clinical features and outcomes of ischemic stroke patients with and without middle cerebral artery (MCA) stenosis, assessed by transcranial sonography (TCS), based on the Taiwan Stroke Registry (TSR). Methods Patients with acute ischemic stroke or transient ischemic attack registered in the TSR, and received both carotid duplex and TCS assessment were categorized into those with stenosis (≥50%) and without (<50%) in the extracranial internal carotid artery (ICA) and MCA, respectively. Logistic regression analysis, Kaplan-Meier method and Cox proportional hazard model were applied to assess relevant variables between groups. Results Of 6003 patients, 23.3% had MCA stenosis, 10.1% ICA stenosis, and 3.9% both MCA and ICA stenosis. Patients with MCA stenosis had greater initial NIHSS, higher likelihood of stroke-in-evolution, and more severe disability than those without (all p<0.001). Patients with MCA stenosis had higher prevalence of hypertension, diabetes and hypercholesterolemia. Patients with combined MCA and extracranial ICA stenosis had even higher NIHSS, worse functional outcome, higher risk of stroke recurrence or death (hazard ratio, 2.204; 95% confidence intervals, 1.440–3.374; p<0.001) at 3 months after stroke than those without MCA stenosis. Conclusions In conclusion, MCA stenosis was more prevalent than extracranial ICA stenosis in ischemic stroke patients in Taiwan. Patients with MCA stenosis, especially combined extracranial ICA stenosis, had more severe neurological deficit and worse outcome. PMID:28388675
Martin, Bryn A; Labuda, Richard; Royston, Thomas J; Oshinski, John N; Iskandar, Bermans; Loth, Francis
2010-11-01
Full explanation for the pathogenesis of syringomyelia (SM), a neuropathology characterized by the formation of a cystic cavity (syrinx) in the spinal cord (SC), has not yet been provided. It has been hypothesized that abnormal cerebrospinal fluid (CSF) pressure, caused by subarachnoid space (SAS) flow blockage (stenosis), is an underlying cause of syrinx formation and subsequent pain in the patient. However, paucity in detailed in vivo pressure data has made theoretical explanations for the syrinx difficult to reconcile. In order to understand the complex pressure environment, four simplified in vitro models were constructed to have anatomical similarities with post-traumatic SM and Chiari malformation related SM. Experimental geometry and properties were based on in vivo data and incorporated pertinent elements such as a realistic CSF flow waveform, spinal stenosis, syrinx, flexible SC, and flexible spinal column. The presence of a spinal stenosis in the SAS caused peak-to-peak cerebrospinal fluid CSF pressure fluctuations to increase rostral to the stenosis. Pressure with both stenosis and syrinx present was complex. Overall, the interaction of the syrinx and stenosis resulted in a diastolic valve mechanism and rostral tensioning of the SC. In all experiments, the blockage was shown to increase and dissociate SAS pressure, while the axial pressure distribution in the syrinx remained uniform. These results highlight the importance of the properties of the SC and spinal SAS, such as compliance and permeability, and provide data for comparison with computational models. Further research examining the influence of stenosis size and location, and the importance of tissue properties, is warranted.
Hoganson, David M; Hinkel, Cameron J; Chen, Xiaomin; Agarwal, Ramesh K; Shenoy, Surendra
2014-01-01
Stenosis in a vascular access circuit is the predominant cause of access dysfunction. Hemodynamic significance of a stenosis identified by angiography in an access circuit is uncertain. This study utilizes computational fluid dynamics (CFD) to model flow through arteriovenous fistula to predict the functional significance of stenosis in vascular access circuits. Three-dimensional models of fistulas were created with a range of clinically relevant stenoses using SolidWorks. Stenoses diameters ranged from 1.0 to 3.0 mm and lengths from 5 to 60 mm within a fistula diameter of 7 mm. CFD analyses were performed using a blood model over a range of blood pressures. Eight patient-specific stenoses were also modeled and analyzed with CFD and the resulting blood flow calculations were validated by comparison with brachial artery flow measured by duplex ultrasound. Predicted flow rates were derived from CFD analysis of a range of stenoses. These stenoses were modeled by CFD and correlated with the ultrasound measured flow rate through the fistula of eight patients. The calculated flow rate using CFD correlated within 20% of ultrasound measured flow for five of eight patients. The mean difference was 17.2% (ranged from 1.3% to 30.1%). CFD analysis-generated flow rate tables provide valuable information to assess the functional significance of stenosis detected during imaging studies. The CFD study can help in determining the clinical relevance of a stenosis in access dysfunction and guide the need for intervention.
Flow Quantification from 2D Phase Contrast MRI in Renal Arteries Using Clustering
NASA Astrophysics Data System (ADS)
Zöllner, Frank G.; Monnsen, Jan Ankar; Lundervold, Arvid; Rørvik, Jarle
We present an approach based on clustering to segment renal arteries from 2D PC Cine MR images to measure blood velocity and flow. Such information are important in grading renal artery stenosis and support the decision on surgical interventions like percutan transluminal angioplasty. Results show that the renal arteries could be extracted automatically and the corresponding velocity profiles could be calculated. Furthermore, the clustering could detect possible phase wrap effects automatically as well as differences in the blood flow patterns within the vessel.
Atrial contribution to ventricular filling in mitral stenosis.
Meisner, J S; Keren, G; Pajaro, O E; Mani, A; Strom, J A; Frater, R W; Laniado, S; Yellin, E L
1991-10-01
The importance of the contribution of atrial systole to ventricular filling in mitral stenosis is controversial. The cause of reduced cardiac output following the onset of atrial fibrillation may be due to an increased heart rate, a loss of booster pump function, or both. We studied the atrial contribution to filling under a variety of conditions by combining noninvasive studies of patients with computer modeling. Thirty patients in sinus rhythm with mild-to-severe stenosis were studied with two-dimensional and Doppler echocardiography for measurement of mitral flow velocity and mitral valve area (MVA). The mean +/- SD atrial contribution to left ventricular filling volume was 18 +/- 10% and varied inversely with mitral resistance. Patients with mild mitral stenosis (MVA, 1.8 +/- 0.7 cm2) and severe mitral stenosis (MVA, 0.9 +/- 0.2 cm2) had atrial contributions of 29 +/- 4% and 9 +/- 5%, respectively. The pathophysiological mechanisms responsible for these trends were further investigated by the computer model. In modeled severe mitral stenosis, increasing heart rate from 75 to 150 beats/min caused an increase of 5.2 mm Hg in mean left atrial pressure, whereas loss of atrial contraction at a heart rate of 150 beats/min caused only a 1.3 mm Hg increase. The atrial booster pump contributes less to ventricular filling in mitral stenosis than in the normal heart, and the loss of atrial pump function is less important than the effect of increasing heart rate as the cause of decompensation during atrial fibrillation.
Runge-Kutta method for wall shear stress of blood flow in stenosed artery
NASA Astrophysics Data System (ADS)
Awaludin, Izyan Syazana; Ahmad, Rokiah@Rozita
2014-06-01
A mathematical model of blood flow through stenotic artery is considered. A stenosis is defined as the partial occlusion of the blood vessels due to the accumulation of cholesterols, fats and the abnormal growth of tissue on the artery walls. The development of stenosis in the artery is one of the factors that cause problem in blood circulation system. This study was conducted to determine the wall shear stress of blood flow in stenosed artery. Modified mathematical model is used to analyze the relationship of the wall shear stress versus the length and height of stenosis. The existing models that have been created by previous researchers are solved using fourth order Runge-Kutta method. Numerical results show that the wall shear stress is proportionate to the length and height of stenosis.
Plaque imaging with CT—a comprehensive review on coronary CT angiography based risk assessment
Kolossváry, Márton; Szilveszter, Bálint; Merkely, Béla
2017-01-01
CT based technologies have evolved considerably in recent years. Coronary CT angiography (CTA) provides robust assessment of coronary artery disease (CAD). Early coronary CTA imaging—as a gate-keeper of invasive angiography—has focused on the presence of obstructive stenosis. Coronary CTA is currently the only non-invasive imaging modality for the evaluation of non-obstructive CAD, which has been shown to contribute to adverse cardiac events. Importantly, improved spatial resolution of CT scanners and novel image reconstruction algorithms enable the quantification and characterization of atherosclerotic plaques. State-of-the-art CT imaging can therefore reliably assess the extent of CAD and differentiate between various plaque features. Recent studies have demonstrated the incremental prognostic value of adverse plaque features over luminal stenosis. Comprehensive coronary plaque assessment holds potential to significantly improve individual risk assessment incorporating adverse plaque characteristics, the extent and severity of atherosclerotic plaque burden. As a result, several coronary CTA based composite risk scores have been proposed recently to determine patients at high risk for adverse events. Coronary CTA became a promising modality for the evaluation of functional significance of coronary lesions using CT derived fractional flow reserve (FFR-CT) and/or rest/dynamic myocardial CT perfusion. This could lead to substantial reduction in unnecessary invasive catheterization procedures and provide information on ischemic burden of CAD. Discordance between the degree of stenosis and ischemia has been recognized in clinical landmark trials using invasive FFR. Both lesion stenosis and composition are possibly related to myocardial ischemia. The evaluation of lesion-specific ischemia using combined functional and morphological plaque information could ultimately improve the diagnostic performance of CTA and thus patient care. In this review we aimed to summarize current evidence on comprehensive coronary artery plaque assessment using coronary CTA. PMID:29255692
Mejean, Simon; Bouvier, Erik; Bataille, Vincent; Seknadji, Patrick; Fourchy, Dominique; Tabet, Jean-Yves; Lairez, Olivier; Cormier, Bertrand
2016-10-15
Mitral annular calcium (MAC) is a common finding in older patients referred for transcatheter aortic valve implantation (TAVI). Multidetector computed tomography (MDCT) allows fine quantification of the calcific deposits. Our objective was to estimate the prevalence of MAC and associated mitral stenosis (MS) in patients referred for TAVI using MDCT. A cohort of 346 consecutive patients referred for TAVI evaluation was screened by MDCT for MAC: 174 had MAC (50%). Of these patients, 165 patients (95%) had mitral valve area (MVA) assessable by MDCT planimetry (age 83.8 ± 5.9 years). Median mitral calcium volume and MVA were 545 mm 3 (193 to 1,253 mm 3 ) and 234 mm 2 (187 to 297 mm 2 ), respectively. The MS was very severe, severe, and moderate in 2%, 22%, and 10% patients, respectively. By multivariate analysis, MVA was independently correlated to mitral calcium volume, aortic annular area, and some specific patterns of mitral leaflet calcium. Based on these findings, a formula was elaborated to predict the presence of a significant MS. In conclusion, MDCT allows detailed assessment of MAC in TAVI populations, demonstrating a high prevalence. Mitral analysis should become routine during MDCT screening before TAVI as it may alter therapeutic strategy. Copyright © 2016 Elsevier Inc. All rights reserved.
Kefayati, Sarah; Milner, Jaques S; Holdsworth, David W; Poepping, Tamie L
2014-01-01
Atherosclerotic disease, and the subsequent complications of thrombosis and plaque rupture, has been associated with local shear stress. In the diseased carotid artery, local variations in shear stress are induced by various geometrical features of the stenotic plaque. Greater stenosis severity, plaque eccentricity (symmetry) and plaque ulceration have been associated with increased risk of cerebrovascular events based on clinical trial studies. Using particle image velocimetry, the levels and patterns of shear stress (derived from both laminar and turbulent phases) were studied for a family of eight matched-geometry models incorporating independently varied plaque features - i.e. stenosis severity up to 70%, one of two forms of plaque eccentricity, and the presence of plaque ulceration). The level of laminar (ensemble-averaged) shear stress increased with increasing stenosis severity resulting in 2-16 Pa for free shear stress (FSS) and approximately double (4-36 Pa) for wall shear stress (WSS). Independent of stenosis severity, marked differences were found in the distribution and extent of shear stress between the concentric and eccentric plaque formations. The maximum WSS, found at the apex of the stenosis, decayed significantly steeper along the outer wall of an eccentric model compared to the concentric counterpart, with a 70% eccentric stenosis having 249% steeper decay coinciding with the large outer-wall recirculation zone. The presence of ulceration (in a 50% eccentric plaque) resulted in both elevated FSS and WSS levels that were sustained longer (∼20 ms) through the systolic phase compared to the non-ulcerated counterpart model, among other notable differences. Reynolds (turbulent) shear stress, elevated around the point of distal jet detachment, became prominent during the systolic deceleration phase and was widely distributed over the large recirculation zone in the eccentric stenoses.
Mahalingam, Arun; Gawandalkar, Udhav Ulhas; Kini, Girish; Buradi, Abdulrajak; Araki, Tadashi; Ikeda, Nobutaka; Nicolaides, Andrew; Laird, John R; Saba, Luca; Suri, Jasjit S
2016-06-01
Local hemodynamics plays an important role in atherogenesis and the progression of coronary atherosclerosis disease (CAD). The primary biological effect due to blood turbulence is the change in wall shear stress (WSS) on the endothelial cell membrane, while the local oscillatory nature of the blood flow affects the physiological changes in the coronary artery. In coronary arteries, the blood flow Reynolds number ranges from few tens to several hundreds and hence it is generally assumed to be laminar while calculating the WSS calculations. However, the pulsatile blood flow through coronary arteries under stenotic condition could result in transition from laminar to turbulent flow condition. In the present work, the onset of turbulent transition during pulsatile flow through coronary arteries for varying degree of stenosis (i.e., 0%, 30%, 50% and 70%) is quantitatively analyzed by calculating the turbulent parameters distal to the stenosis. Also, the effect of turbulence transition on hemodynamic parameters such as WSS and oscillatory shear index (OSI) for varying degree of stenosis is quantified. The validated transitional shear stress transport (SST) k-ω model used in the present investigation is the best suited Reynolds averaged Navier-Stokes turbulence model to capture the turbulent transition. The arterial wall is assumed to be rigid and the dynamic curvature effect due to myocardial contraction on the blood flow has been neglected. Our observations shows that for stenosis 50% and above, the WSSavg, WSSmax and OSI calculated using turbulence model deviates from laminar by more than 10% and the flow disturbances seems to significantly increase only after 70% stenosis. Our model shows reliability and completely validated. Blood flow through stenosed coronary arteries seems to be turbulent in nature for area stenosis above 70% and the transition to turbulent flow begins from 50% stenosis.
Numerical analysis of urine flow through the side holes of a double J stent in a ureteral stenosis.
Kim, Hyoung-Ho; Choi, Young Ho; Lee, Seung Bae; Baba, Yasutaka; Kim, Kyung-Wuk; Suh, Sang-Ho
2017-07-20
Ureteral stenosis presents with a narrowing in the ureter, due to an intrinsic or extrinsic ureteral disease, such as ureter cancer or retroperitoneal fibrosis. The placement of a double J stent in the upper urinary system is one of the most common treatments of ureteral stenosis, along with the insertion of a percutaneous nephrostomy tube into the renal pelvis. The effect that the side holes in a double J stent have on urine flow has been evaluated in a few studies using straight ureter models. In this study, urine flow through a double J stent's side holes was analyzed in curved ureter models, which were based on human anatomy. In ureteral stenosis, especially in severe ureteral stenosis, a stent with side holes had a positive effect on the luminal and total flow rates, compared with the rates for a stent without side holes. The more side holes a stent has, the greater the luminal and total flow rates. However, the angular positions of the side holes did not affect flow rate. In conclusion, the side holes in a double J stent had a positive effect on ureteral stenosis, and the effect became greater as the ureteral stenosis became more severe.
Ceballos, Andres; Argueta-Morales, I Ricardo; Divo, Eduardo; Osorio, Ruben; Caldarone, Christopher A; Kassab, Alain J; Decampli, William M
2012-11-01
The hemodynamics characteristics of the hybrid Norwood (HN) procedure differ from those of the conventional Norwood and are not fully understood. We present a multiscale model of HN circulation to understand local hemodynamics and effects of aortic arch stenosis and a reverse Blalock-Taussig shunt (RBTS) on coronary and carotid perfusion. Four 3-dimensional models of four HN anatomic variants were developed, with and without 90% distal preductal arch stenosis and with and without a 4-mm RBTS. A lumped parameter model of the circulation was coupled to a local 3-dimensional computational fluid dynamics model. Outputs from the lumped parameter model provided waveform boundary conditions for the computational fluid dynamics model. A 90% distal arch stenosis reduced pressure and net flow-rate through the coronary and carotid arteries by 30%. Addition of the RBTS completely restored pressure and flow rate to baseline in these vessels. Zones of flow stagnation, flow reversal, and recirculation in the presence of stenosis were rendered more orderly by addition of the RBTS. In the absence of stenosis, presence of the shunt resulted in extensive zones of disturbed flow within the RBTS and arch. We found that a 4-mm × 21-mm RBTS completely compensated for the effects of a 90% discrete stenosis of the distal aortic arch in the HN. Placed preventatively, the RBTS and arch displayed zones with thrombogenic potential showing recirculation and stagnation that persist for a substantial fraction of the cardiac cycle, indicating that anticoagulation should be considered with a prophylactic RBTS. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Moroni, Francesco; Magnoni, Marco; Vergani, Vittoria; Ammirati, Enrico; Camici, Paolo G
2018-01-01
Plaque border irregularity is a known imaging characteristic of vulnerable plaques, but its evaluation heavily relies on subjective evaluation and operator expertise. Aim of the present work is to propose a novel fractal-analysis based method for the quantification of atherosclerotic plaque border irregularity and assess its relation with cardiovascular risk factors. Forty-two asymptomatic subjects with carotid stenosis underwent ultrasound evaluation and assessment of cardiovascular risk factors. Total, low-density lipoprotein (LDL), high-density lipoprotein (HDL) plasma cholesterol and triglycerides concentrations were measured for each subject. Fractal analysis was performed in all the carotid segments affected by atherosclerosis, i.e. 147 segments. The resulting fractal dimension (FD) is a measure of irregularity of plaque profile on long axis view of the plaque. FD in the severest stenosis (main plaque FD,mFD) was 1.136±0.039. Average FD per patient (global FD,gFD) was 1.145±0.039. FD was independent of other plaque characteristics. mFD significantly correlated with plasma HDL (r = -0.367,p = 0.02) and triglycerides-to-HDL ratio (r = 0.480,p = 0.002). Fractal analysis is a novel, readily available, reproducible and inexpensive technique for the quantitative measurement of plaque irregularity. The correlation between low HDL levels and plaque FD suggests a role for HDL in the acquisition of morphologic features of plaque instability. Further studies are needed to validate the prognostic value of fractal analysis in carotid plaques evaluation.
Staub, Daniel; Partovi, Sasan; Zeller, Thomas; Breidthardt, Tobias; Kaech, Max; Boeddinghaus, Jasper; Puelacher, Christian; Nestelberger, Thomas; Aschwanden, Markus; Mueller, Christian
2016-06-01
Identifying patients likely to have improved renal function after percutaneous transluminal renal angioplasty and stenting (PTRA) for renal artery stenosis (RAS) is challenging. The purpose of this study was to use a comprehensive multimarker assessment to identify those patients who would benefit most from correction of RAS. In 127 patients with RAS and decreased renal function and/or hypertension referred for PTRA, quantification of hemodynamic cardiac stress using B-type natriuretic peptide (BNP), renal function using estimated glomerular filtration rate (eGFR), parenchymal renal damage using resistance index (RI), and systemic inflammation using C-reactive protein (CRP) were performed before intervention. Predefined renal function improvement (increase in eGFR ≥10%) at 6 months occurred in 37% of patients. Prognostic accuracy as quantified by the area under the receiver-operating characteristics curve for the ability of BNP, eGFR, RI and CRP to predict renal function improvement were 0.59 (95% CI, 0.48-0.70), 0.71 (95% CI, 0.61-0.81), 0.52 (95% CI, 0.41-0.65), and 0.56 (95% CI, 0.44-0.68), respectively. None of the possible combinations increased the accuracy provided by eGFR (lower eGFR indicated a higher likelihood for eGFR improvement after PTRA, P=ns for all). In the subgroup of 56 patients with pre-interventional eGFR <60 mL/min/1.73 m(2), similar findings were obtained. Quantification of renal function, but not any other pathophysiologic signal, provides at least moderate accuracy in the identification of patients with RAS in whom PTRA will improve renal function.
Yan, Z; Liang, Y; Shi, J; Cai, C; Jiang, H; Song, A; Qiu, C
2016-01-01
The possible association between carotid stenosis and cognitive impairment in the Chinese population has been rarely investigated. The association between the severity of carotid stenosis and cognitive impairment amongst older Chinese people living in a rural area was assessed. This cross-sectional study included 1375 participants (age ≥60 years) from the Confucius Hometown Aging Project in Shandong. In 2010-2011, data were collected through interviews and clinical examinations. Carotid stenosis was assessed using ultrasonography. Cognitive impairment was defined according to the education-specific cutoff scores of the Mini-Mental State Examination. Data were analyzed using multinomial logistic models. The overall prevalence was 7.0% for moderate carotid stenosis, 2.0% for severe stenosis and 6.0% for cognitive impairment. The multi-adjusted odds ratio of cognitive impairment was 1.43 (95% confidence interval 0.63-3.22) for moderate carotid stenosis and 3.75 (1.24-11.40) for severe carotid stenosis (P(trend) = 0.023). Similar results were obtained in people without a history of cerebrovascular disease. Severe carotid stenosis, even asymptomatic, is associated with cognitive impairment independent of atherosclerotic risk factors and disorders amongst older Chinese people. © 2015 EAN.
Wu, Ming-Jui; Chen, Wei-Ling; Kan, Chung-Dann; Yu, Fan-Ming; Wang, Su-Chin; Lin, Hsiu-Hui; Lin, Chia-Hung
2015-12-01
In physical examinations, hemodialysis access stenosis leading to dysfunction occurs at the venous anastomosis site or the outflow vein. Information from the inflow stenosis, such as blood pressure, pressure drop, and flow resistance increases, allows dysfunction screening from the stage of early clots and thrombosis to the progression of outflow stenosis. Therefore, this study proposes dysfunction screening model in experimental arteriovenous grafts (AVGs) using the fractional-order extractor (FOE) and the color relation analysis (CRA). A Sprott system was designed using an FOE to quantify the differences in transverse vibration pressures between the inflow and outflow sites of an AVG. Experimental analysis revealed that the degree of stenosis (DOS) correlated with an increase in fractional-order dynamic errors (FODEs). Exponential regression was used to fit a non-linear curve and can be used to quantify the relationship between the FODEs and DOS (R (2) = 0.8064). The specific ranges were used to evaluate the stenosis degree, such as DOS: <50, 50-80, and >80%. A CRA-based screening method was derived from the hue angle-saturation-value color model, which describes perceptual color relationships for the DOS. It has a flexibility inference manner with color visualization to represent the different stenosis degrees, which has average accuracy >90% superior to the traditional methods. This in vitro experimental study demonstrated that the proposed model can be used for dysfunction screening in stenotic AVGs.
Zhang, Chi; Wang, Ling; Li, Xiaoyun; Li, Shuyu; Pu, Fang; Fan, Yubo; Li, Deyu
2014-01-01
Circle of Willis (CoW) plays a significant role in maintaining the blood supply for the brain. Specifically, when the stenosis occurs in the internal carotid artery (ICA), abnormal structures of CoW would decrease the compensatory capacity, leading to the local insufficiency of cerebral blood supply. The present paper built a series of lumped parameter models for CoW, and simulated the blood redistribution caused by the unilateral ICA stenosis with different severities in cerebral arteries in the normal and abnormal CoW respectively. The results showed that when unilateral ICA stenosis occurred, the collateral circulation was built through the anterior communicating artery and the ipsilateral posterior communicating artery, maintaining the flow in cerebral arteries. The absence of the two communicating arteries would cause an obvious decrease of flow in local cerebral arteries in the anterior circulation. In conclusion, the two arteries play a significant role in maintaining the balance of cerebral blood supply in the development of ICA stenosis.
NASA Astrophysics Data System (ADS)
Nadeem, S.; Ijaz, S.
2016-07-01
In this paper hemodynamics of stenosis are discussed to predict effect of atherosclerosis by means of mathematical models in the presence of uniform transverse magnetic field. The analysis is carried out using silver and copper nanoparticles as a drug carrier. Exact solution for the fluid temperature, velocity, axial induced magnetic field and current density distribution are obtained under mild stenosis approximation. The results indicate that with an increase in the concentration of nanoparticle hemodynamics effects of stenosis reduces throughout the inclined composite stenosed arteries. The considered analysis also summarizes that the drug silver nanoparticles is more efficient to reduce hemodynamics of stenosis when compare to the drug copper nanoparticle. In future this model could be helpful to predict important properties in some biomedical applications.
Turbulence modeling in three-dimensional stenosed arterial bifurcations.
Banks, J; Bressloff, N W
2007-02-01
Under normal healthy conditions, blood flow in the carotid artery bifurcation is laminar. However, in the presence of a stenosis, the flow can become turbulent at the higher Reynolds numbers during systole. There is growing consensus that the transitional k-omega model is the best suited Reynolds averaged turbulence model for such flows. Further confirmation of this opinion is presented here by a comparison with the RNG k-epsilon model for the flow through a straight, nonbifurcating tube. Unlike similar validation studies elsewhere, no assumptions are made about the inlet profile since the full length of the experimental tube is simulated. Additionally, variations in the inflow turbulence quantities are shown to have no noticeable affect on downstream turbulence intensity, turbulent viscosity, or velocity in the k-epsilon model, whereas the velocity profiles in the transitional k-omega model show some differences due to large variations in the downstream turbulence quantities. Following this validation study, the transitional k-omega model is applied in a three-dimensional parametrically defined computer model of the carotid artery bifurcation in which the sinus bulb is manipulated to produce mild, moderate, and severe stenosis. The parametric geometry definition facilitates a powerful means for investigating the effect of local shape variation while keeping the global shape fixed. While turbulence levels are generally low in all cases considered, the mild stenosis model produces higher levels of turbulent viscosity and this is linked to relatively high values of turbulent kinetic energy and low values of the specific dissipation rate. The severe stenosis model displays stronger recirculation in the flow field with higher values of vorticity, helicity, and negative wall shear stress. The mild and moderate stenosis configurations produce similar lower levels of vorticity and helicity.
Govindaraju, Kalimuthu; Viswanathan, Girish N; Badruddin, Irfan Anjum; Kamangar, Sarfaraz; Salman Ahmed, N J; Al-Rashed, Abdullah A A A
2016-11-01
This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.
Gawandalkar, Udhav Ulhas; Kini, Girish; Buradi, Abdulrajak; Araki, Tadashi; Ikeda, Nobutaka; Nicolaides, Andrew; Laird, John R.; Saba, Luca; Suri, Jasjit S.
2016-01-01
Background Local hemodynamics plays an important role in atherogenesis and the progression of coronary atherosclerosis disease (CAD). The primary biological effect due to blood turbulence is the change in wall shear stress (WSS) on the endothelial cell membrane, while the local oscillatory nature of the blood flow affects the physiological changes in the coronary artery. In coronary arteries, the blood flow Reynolds number ranges from few tens to several hundreds and hence it is generally assumed to be laminar while calculating the WSS calculations. However, the pulsatile blood flow through coronary arteries under stenotic condition could result in transition from laminar to turbulent flow condition. Methods In the present work, the onset of turbulent transition during pulsatile flow through coronary arteries for varying degree of stenosis (i.e., 0%, 30%, 50% and 70%) is quantitatively analyzed by calculating the turbulent parameters distal to the stenosis. Also, the effect of turbulence transition on hemodynamic parameters such as WSS and oscillatory shear index (OSI) for varying degree of stenosis is quantified. The validated transitional shear stress transport (SST) k-ω model used in the present investigation is the best suited Reynolds averaged Navier-Stokes turbulence model to capture the turbulent transition. The arterial wall is assumed to be rigid and the dynamic curvature effect due to myocardial contraction on the blood flow has been neglected. Results Our observations shows that for stenosis 50% and above, the WSSavg, WSSmax and OSI calculated using turbulence model deviates from laminar by more than 10% and the flow disturbances seems to significantly increase only after 70% stenosis. Our model shows reliability and completely validated. Conclusions Blood flow through stenosed coronary arteries seems to be turbulent in nature for area stenosis above 70% and the transition to turbulent flow begins from 50% stenosis. PMID:27280084
Prediction of Thrombus Growth: Effect of Stenosis and Reynolds Number.
Hosseinzadegan, Hamid; Tafti, Danesh K
2017-06-01
Shear stresses play a major role in platelet-substrate interactions and thrombus formation and growth in blood flow, where under both pathological and physiological conditions platelet adhesion and accumulation occur. In this study, a shear-dependent continuum model for platelet activation, adhesion and aggregation is presented. The model was first verified under three different shear conditions and at two heparin levels. Three-dimensional simulations were then carried out to evaluate the performance of the model for severely damaged (stripped) aortas with mild and severe stenosis degrees in laminar flow regime. For these cases, linear shear-dependent functions were developed for platelet-surface and platelet-platelet adhesion rates. It was confirmed that the platelet adhesion rate is not only a function of Reynolds number (or wall shear rate) but also the stenosis severity of the vessel. General correlations for adhesion rates of platelets as functions of stenosis and Reynolds number were obtained based on these cases. Finally using the new platelet adhesion rates, the model was applied to different experimental systems and shown to agree well with measured platelet deposition.
NASA Technical Reports Server (NTRS)
Bathe, M.; Kamm, R. D.
1999-01-01
A new model is used to analyze the fully coupled problem of pulsatile blood flow through a compliant, axisymmetric stenotic artery using the finite element method. The model uses large displacement and large strain theory for the solid, and the full Navier-Stokes equations for the fluid. The effect of increasing area reduction on fluid dynamic and structural stresses is presented. Results show that pressure drop, peak wall shear stress, and maximum principal stress in the lesion all increase dramatically as the area reduction in the stenosis is increased from 51 to 89 percent. Further reductions in stenosis cross-sectional area, however, produce relatively little additional change in these parameters due to a concomitant reduction in flow rate caused by the losses in the constriction. Inner wall hoop stretch amplitude just distal to the stenosis also increases with increasing stenosis severity, as downstream pressures are reduced to a physiological minimum. The contraction of the artery distal to the stenosis generates a significant compressive stress on the downstream shoulder of the lesion. Dynamic narrowing of the stenosis is also seen, further augmenting area constriction at times of peak flow. Pressure drop results are found to compare well to an experimentally based theoretical curve, despite the assumption of laminar flow.
Oh, Jun-Hyok; Song, Seunghwan; Kim, Changhoon; Kim, Jeongsu; Sup Park, Jin; Won Lee, Hye; Hyun Choi, Jung; Cheol Lee, Han; Soo Cha, Kwang; Jong Hong, Taek
2017-02-01
The aim of this study was to explore the effect of one stenosis in a daughter artery on the fractional flow reserve (FFR) of another stenosis parallels in side branch. The impact of one stenosis on the FFR of another parallel stenosis has not been evaluated. The proximal segments of the left anterior descending (LAD) and left circumflex (LCX) arteries were exposed and encircled with a Teflon pledget complex in seven swine (55-70 kg). Five degrees of stenosis (to approximate angiographic diameter stenoses of 0%, 25%, 50%, 75%, and 100%) were made by tightening the pledgets. FFR was evaluated simultaneously in the LAD and the LCX with two pressure wires in each coronary artery. A mixed-effects linear model was used to evaluate the association between the FFR values. A total of 115 paired FFR values were obtained. The FFR of the LAD and LCX were not significantly associated with each other (F = 0.237 and P = 0.627 for the LCX FFR to predict the LAD FFR; F = 0.541 and P = 0.463 for the LAD FFR to predict the LCX FFR). The individual FFR values of each parallel stenosis in the LAD and the LCX were not significantly influenced by each other. This relationship was independent of the mean aortic pressure and heart rate. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis
NASA Astrophysics Data System (ADS)
Doriot, Pierre-André
2003-01-01
Mechanical stresses in arterial walls are known to be implicated in the development of atherosclerosis. While shear stress and circumferential stress have received a lot of attention, axial stress has not. Yet, stenoses can be intuitively expected to produce a supplementary axial stress during flow systole in the region immediately proximal to the constriction cone. In this paper, a model for the estimation of this effect is presented, and ten numerical examples are computed. These examples show that the cyclic increase in axial stress can be quite considerable in severe stenoses (typically 120% or more of the normal stress value). This result is in best agreement with the known mechanical or morphological risk factors of stenosis progression and restenosis (hypertension, elevated pulse pressure, degree of stenosis, stenosis geometry, residual stenosis, etc). The supplementary axial stress generated by a stenosis might create the damages in the endothelium and in the elastic membranes which potentiate the action of the other risk factors (hyperlipidaemia, diabetes, etc). It could thus be an important cause of stenosis progression and of restenosis.
Mathematical modelling of the human cardiovascular system in the presence of stenosis
NASA Technical Reports Server (NTRS)
Sud, V. K.; Srinivasan, R. S.; Charles, J. B.; Bungo, M. W.
1993-01-01
This paper reports a theoretical study on the distribution of blood flow in the human cardiovascular system when one or more blood vessels are affected by stenosis. The analysis employs a mathematical model of the entire system based on the finite element method. The arterial-venous network is represented by a large number of interconnected segments in the model. Values for the model parameters are based upon the published data on the physiological and rheological properties of blood. Computational results show how blood flow through various parts of the cardiovascular system is affected by stenosis in different blood vessels. No significant changes in the flow parameters of the cardiovascular system were found to occur when the reduction in the lumen diameter of the stenosed vessels was less than 65%.
Partovi, Sasan; Zeller, Thomas; Breidthardt, Tobias; Kaech, Max; Boeddinghaus, Jasper; Puelacher, Christian; Nestelberger, Thomas; Aschwanden, Markus; Mueller, Christian
2016-01-01
Background Identifying patients likely to have improved renal function after percutaneous transluminal renal angioplasty and stenting (PTRA) for renal artery stenosis (RAS) is challenging. The purpose of this study was to use a comprehensive multimarker assessment to identify those patients who would benefit most from correction of RAS. Methods In 127 patients with RAS and decreased renal function and/or hypertension referred for PTRA, quantification of hemodynamic cardiac stress using B-type natriuretic peptide (BNP), renal function using estimated glomerular filtration rate (eGFR), parenchymal renal damage using resistance index (RI), and systemic inflammation using C-reactive protein (CRP) were performed before intervention. Results Predefined renal function improvement (increase in eGFR ≥10%) at 6 months occurred in 37% of patients. Prognostic accuracy as quantified by the area under the receiver-operating characteristics curve for the ability of BNP, eGFR, RI and CRP to predict renal function improvement were 0.59 (95% CI, 0.48–0.70), 0.71 (95% CI, 0.61–0.81), 0.52 (95% CI, 0.41–0.65), and 0.56 (95% CI, 0.44–0.68), respectively. None of the possible combinations increased the accuracy provided by eGFR (lower eGFR indicated a higher likelihood for eGFR improvement after PTRA, P=ns for all). In the subgroup of 56 patients with pre-interventional eGFR <60 mL/min/1.73 m2, similar findings were obtained. Conclusions Quantification of renal function, but not any other pathophysiologic signal, provides at least moderate accuracy in the identification of patients with RAS in whom PTRA will improve renal function. PMID:27280085
Chittiboina, Prashant; Guthikonda, Bharat; Wollblad, Christian; Conrad, Steven A
2011-01-01
Cerebral vasospasm after aneurysmal subarachnoid hemorrhage is a potentially severe sequel. The induction of hypertension, hypervolemia, and hemodilution is advocated for vasospasm, but it is unclear whether hemodilution confers any benefit. A finite element model of oxygen transport in the proximal middle cerebral artery (MCA) was used to evaluate the complex relationship among hematocrit, viscosity, oxygen content, and blood flow in the setting of vasospasm. A single-phase non-Newtonian finite element model based on three-dimensional incompressible Navier–Stokes equations was constructed of the M1 segment. The model was solved at vessel stenoses ranging from 0% to 90% and hematocrit from 0.2 to 0.6. A small area of poststenotic recirculation was seen with mild (30%) stenosis. Poststenotic eddy formation was noted with more severe (60% to 90%) stenosis. Volumetric flow was inversely related to hematocrit at mild stenosis (0% to 30%). With near-complete stenosis (90%), a paradoxical increase in flow was seen with increasing hematocrit. Oxygen transport across the segment was related to hematocrit at all levels of stenosis with increasing oxygen transport despite a reduction in blood flow, suggesting that with clinically significant vasospasm in the MCA, hemodilution does not improve oxygen transport, but to the contrary, that ischemia may be worsened. PMID:21629259
Keshavarz-Motamed, Z; Garcia, J; Kadem, L
2011-01-01
Coarctation of the aorta is an obstruction of the aorta and is usually associated with other concomitant cardiovascular abnormalities especially with bicuspid aortic valve stenosis. The objectives of this study are, (1) to investigate the effects of coarctation on the hemodynamics in the aorta to gain a better understanding of the cause of certain post-surgical coarctation problems, (2) to develop and introduce a new lumped parameter model, mainly based on non-invasive data, allowing the description of the interaction between left ventricle, coarctation of the aorta, aortic valve stenosis, and the arterial system.
Chaichana, Thanapong
2017-01-01
Background To investigate the correlation between left coronary bifurcation angle and coronary stenosis as assessed by coronary computed tomography angiography (CCTA)-generated computational fluid dynamics (CFD) analysis when compared to the CCTA analysis of coronary lumen stenosis and plaque lesion length with invasive coronary angiography (ICA) as the reference method. Methods Thirty patients (22 males, mean age: 59±6.9 years) with calcified plaques at the left coronary artery were included in the study with all patients undergoing CCTA and ICA examinations. CFD simulation was performed to analyze hemodynamic changes to the left coronary artery models in terms of wall shear stress, wall pressure and flow velocity, with findings correlated to the coronary stenosis and degree of bifurcation angle. Calcified plaque length was measured in the left coronary artery with diagnostic value compared to that from coronary lumen and bifurcation angle assessments. Results Of 26 significant stenosis at left anterior descending (LAD) and 13 at left circumflex (LCx) on CCTA, only 14 and 5 of them were confirmed to be >50% stenosis at LAD and LCx respectively on ICA, resulting in sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 100%, 52%, 49% and 100%. The mean plaque length was measured 5.3±3.6 and 4.4±1.9 mm at LAD and LCx, respectively, with diagnostic sensitivity, specificity, PPV and NPV being 92.8%, 46.7%, 61.9% and 87.5% for extensively calcified plaques. The mean bifurcation angle was measured 83.9±13.6º and 83.8±13.3º on CCTA and ICA, respectively, with no significant difference (P=0.98). The corresponding sensitivity, specificity, PPV and NPV were 100%, 78.6%, 84.2% and 100% based on bifurcation angle measurement on CCTA, 100%, 73.3%, 78.9% and 100% based on bifurcation angle measurements on ICA, respectively. Wall shear stress was noted to increase in the LAD and LCx models with significant stenosis and wider angulation (>80º), but demonstrated little or no change in most of the coronary models with no significant stenosis and narrower angulation (<80º). Conclusions This study further clarifies the relationship between left coronary bifurcation angle and significant stenosis, with angulation measurement serving as a more accurate approach than coronary lumen assessment or plaque lesion length for determining significant coronary stenosis. Left coronary bifurcation angle is suggested to be incorporated into coronary artery disease (CAD) assessment when diagnosing significant CAD. PMID:29184766
Fujimoto, Yoshitaka; Urashima, Takashi; Kawachi, Fumie; Akaike, Toru; Kusakari, Yoichiro; Ida, Hiroyuki; Minamisawa, Susumu
2017-11-01
A rat model of left atrial stenosis-associated pulmonary hypertension due to left heart diseases was prepared to elucidate its mechanism. Five-week-old Sprague-Dawley rats were randomly divided into 2 groups: left atrial stenosis and sham-operated control. Echocardiography was performed 2, 4, 6, and 10 weeks after surgery, and cardiac catheterization and organ excision were subsequently performed at 10 weeks after surgery. Left ventricular inflow velocity, measured by echocardiography, significantly increased in the left atrial stenosis group compared with that in the sham-operated control group (2.2 m/s, interquartile range [IQR], 1.9-2.2 and 1.1 m/s, IQR, 1.1-1.2, P < .01), and the right ventricular pressure-to-left ventricular systolic pressure ratio significantly increased in the left atrial stenosis group compared with the sham-operated control group (0.52, IQR, 0.54-0.60 and 0.22, IQR, 0.15-0.27, P < .01). The right ventricular weight divided by body weight was significantly greater in the left atrial stenosis group than in the sham-operated control group (0.54 mg/g, IQR, 0.50-0.59 and 0.39 mg/g, IQR, 0.38-0.43, P < .01). Histologic examination revealed medial hypertrophy of the pulmonary vein was thickened by 1.6 times in the left atrial stenosis group compared with the sham-operated control group. DNA microarray analysis and real-time polymerase chain reaction revealed that transforming growth factor-β mRNA was significantly elevated in the left atrial stenosis group. The protein levels of transforming growth factor-β and endothelin-1 were increased in the lung of the left atrial stenosis group by Western blot analyses. We successfully established a novel, feasible rat model of pulmonary hypertension due to left heart diseases by generating left atrial stenosis. Although pulmonary hypertension was moderate, the pulmonary hypertension due to left heart diseases model rats demonstrated characteristic intrapulmonary venous arterialization and should be used to further investigate the mechanism of pulmonary hypertension due to left heart diseases. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Hibino, Narutoshi; Yi, Tai; Duncan, Daniel R.; Rathore, Animesh; Dean, Ethan; Naito, Yuji; Dardik, Alan; Kyriakides, Themis; Madri, Joseph; Pober, Jordan S.; Shinoka, Toshiharu; Breuer, Christopher K.
2011-01-01
The primary graft-related complication during the first clinical trial evaluating the use of tissue-engineered vascular grafts (TEVGs) was stenosis. We investigated the role of macrophages in the formation of TEVG stenosis in a murine model. We analyzed the natural history of TEVG macrophage infiltration at critical time points and evaluated the role of cell seeding on neovessel formation. To assess the function of infiltrating macrophages, we implanted TEVGs into mice that had been macrophage depleted using clodronate liposomes. To confirm this, we used a CD11b-diphtheria toxin-receptor (DTR) transgenic mouse model. Monocytes infiltrated the scaffold within the first few days and initially transformed into M1 macrophages. As the scaffold degraded, the macrophage infiltrate disappeared. Cell seeding decreased the incidence of stenosis (32% seeded, 64% unseeded, P=0.024) and the degree of macrophage infiltration at 2 wk. Unseeded TEVGs demonstrated conversion from M1 to M2 phenotype, whereas seeded grafts did not. Clodronate and DTR inhibited macrophage infiltration and decreased stenosis but blocked formation of vascular neotissue, evidenced by the absence of endothelial and smooth muscle cells and collagen. These findings suggest that macrophage infiltration is critical for neovessel formation and provides a strategy for predicting, detecting, and inhibiting stenosis in TEVGs.—Hibino, N., Yi, T., Duncan, D. R., Rathore, A., Dean, E., Naito, Y., Dardik, A., Kyriakides, T., Madri, J., Pober, J. S., Shinoka, T., Breuer, C. K. A critical role for macrophages in neovessel formation and the development of stenosis in tissue-engineered vascular grafts. PMID:21865316
Yang, Yu-Shang; Hu, Wei-Peng; Ni, Peng-Zhi; Wang, Wen-Ping; Yuan, Yong; Chen, Long-Qi
2017-06-27
Predictive value of preoperative endoscopic characteristic of esophageal tumor has not been fully evaluated. The aim of this study is to investigate the impact of esophageal luminal stenosis on survival for patients with resectable esophageal squamous cell carcinoma (ESCC). The clinicopathologic characteristics of 623 ESCC patients who underwent curative resection as the primary treatment between January 2005 and April 2009 were retrospectively reviewed. The esophageal luminal stenosis measured by endoscopy was defined as a uniform measurement preoperatively. The impact of esophageal luminal stenosis on patients' overall survival (OS) and relation with other clinicopathological features were assessed. A Cox regression model was used to identify prognostic factors. The results showed that OS significantly decreased in patients with manifest stenotic tumor compared with patients without luminal obstruction (P<0.05). Considerable esophageal luminal stenosis was associated with a higher T stage, longer tumor length, and poorer differentiation (all P<0.05). In multivariate survival analysis, esophageal luminal stenosis remained as an independent prognostic factor for OS (P= 0.036). Esophageal luminal stenosis could have a significant impact on the OS in patients with resected ESCC and may provide additional prognostic value to the current staging system before any cancer-specific treatment.
Correlation between Reynolds number and eccentricity effect in stenosed artery models.
Javadzadegan, Ashkan; Shimizu, Yasutomo; Behnia, Masud; Ohta, Makoto
2013-01-01
Flow recirculation and shear strain are physiological processes within coronary arteries which are associated with pathogenic biological pathways. Distinct Quite apart from coronary stenosis severity, lesion eccentricity can cause flow recirculation and affect shear strain levels within human coronary arteries. The aim of this study is to analyse the effect of lesion eccentricity on the transient flow behaviour in a model of a coronary artery and also to investigate the correlation between Reynolds number (Re) and the eccentricity effect on flow behaviour. A transient particle image velocimetry (PIV) experiment was implemented in two silicone based models with 70% diameter stenosis, one with eccentric stenosis and one with concentric stenosis. At different times throughout the flow cycle, the eccentric model was always associated with a greater recirculation zone length, maximum shear strain rate and maximum axial velocity; however, the highest and lowest impacts of eccentricity were on the recirculation zone length and maximum shear strain rate, respectively. Analysis of the results revealed a negative correlation between the Reynolds number (Re) and the eccentricity effect on maximum axial velocity, maximum shear strain rate and recirculation zone length. As Re number increases the eccentricity effect on the flow behavior becomes negligible.
Lazoura, Olga; Zacharoulis, Dimitris; Kanavou, Theodora; Rountas, Christos; Katsimboulas, Michael; Tzovaras, George; Habib, Nagy
2011-01-01
To develop a new rabbit model of arterial stenosis using endovascular radiofrequency (RF) energy. Ten rabbits were used for multiple endovascular RF applications to the aorta and left common carotid artery through the Habib™ VesCoag™ catheter. Angiography and color Doppler ultrasound were used to assess vessel patency immediately following the procedure and six weeks later. One rabbit was sacrificed following the procedure for histopathologic analysis of the vessel wall. Two rabbits died of aortic and carotid rupture, respectively, immediately after the procedure. The remaining seven rabbits were sacrificed after six-week follow-up for histopathological analysis. Optimal RF generator settings to induce significant arterial stenosis (>50%) without complications were standardized at 24-26 watts (W) for 1.5 min for the aorta and 6 W for 1 min for the common carotid artery. The six-week follow-up showed permanent results in all surviving rabbits. Histopathology revealed intima and medial smooth muscle layer necrosis. We have developed a novel rabbit model of arterial stenosis using endovascular RF energy. Our model is fast, safe, inexpensive, and reproducible. It would be useful for experimental investigations and new therapeutic devices.
Abdollahzadeh Jamalabadi, Mohammad Yaghoub; Daqiqshirazi, Mohammadreza; Nasiri, Hossein; Safaei, Mohammad Reza; Nguyen, Truong Khang
2018-01-01
We present a numerical investigation of tapered arteries that addresses the transient simulation of non-Newtonian bio-magnetic fluid dynamics (BFD) of blood through a stenosis artery in the presence of a transverse magnetic field. The current model is consistent with ferro-hydrodynamic (FHD) and magneto-hydrodynamic (MHD) principles. In the present work, blood in small arteries is analyzed using the Carreau-Yasuda model. The arterial wall is assumed to be fixed with cosine geometry for the stenosis. A parametric study was conducted to reveal the effects of the stenosis intensity and the Hartman number on a wide range of flow parameters, such as the flow velocity, temperature, and wall shear stress. Current findings are in a good agreement with recent findings in previous research studies. The results show that wall temperature control can keep the blood in its ideal blood temperature range (below 40°C) and that a severe pressure drop occurs for blockages of more than 60 percent. Additionally, with an increase in the Ha number, a velocity drop in the blood vessel is experienced.
Gasper, Warren J; Jimenez, Cynthia A; Walker, Joy; Conte, Michael S; Seward, Kirk; Owens, Christopher D
2013-12-01
Endovascular interventions on peripheral arteries are limited by high rates of restenosis. Our hypothesis was that adventitial injection of rapamycin nanoparticles would be safe and reduce luminal stenosis in a porcine femoral artery balloon angioplasty model. Eighteen juvenile male crossbred swine were included. Single-injury (40%-60% femoral artery balloon overstretch injury; n=2) and double-injury models (endothelial denudation injury 2 weeks before a 20%-30% overstretch injury; n=2) were compared. The double-injury model produced significantly more luminal stenosis at 28 days, P=0.002, and no difference in medial fibrosis or inflammation. Four pigs were randomized to the double-injury model and adventitial injection of saline (n=2) or 500 μg of nanoparticle albumin-bound rapamycin (nab-rapamycin; n=2) with an endovascular microinfusion catheter. There was 100% procedural success and no difference in endothelial regeneration. At 28 days, nab-rapamycin led to significant reductions in luminal stenosis, 17% (interquartile range, 12%-35%) versus 10% (interquartile range, 8.3%-14%), P=0.001, medial cell proliferation, P<0.001, and fibrosis, P<0.001. There were significantly fewer adventitial leukocytes at 3 days, P<0.001, but no difference at 28 days. Pharmacokinetic analysis (single-injury model) found rapamycin concentrations 1500× higher in perivascular tissues than in blood at 1 hour. Perivascular rapamycin persisted ≥8 days and was not detectable at 28 days. Adventitial nab-rapamycin injection was safe and significantly reduced luminal stenosis in a porcine femoral artery balloon angioplasty model. Observed reductions in early adventitial leukocyte infiltration and late medial cell proliferation and fibrosis suggest an immunosuppressive and antiproliferative mechanism. An intraluminal microinfusion catheter for adventitial injection represents an alternative to stent- or balloon-based local drug delivery.
Mehrad, Hossein; Mokhtari-Dizaji, Manijhe; Ghanaati, Hossein; Shahbazfar, Amir-Ali; Salehnia, Mojdeh
2012-08-01
Advanced carotid atherosclerosis with severe stenosis (>70%) is a major clinical risk factor for ischemic stroke. Our ability to test new protocols for the treatment of atherosclerotic stenosis in humans is limited for obvious ethical reasons; therefore, a suitable animal model is required. The aim of this study was to generate an easily reproducible and inexpensive experimental rabbit carotid model of advanced atherosclerosis with morphological similarities to the human disease and the subsequent assessment of the reliability of B-mode ultrasound technology in the study of lumen area stenosis in this model. Briefly, New Zealand white rabbits underwent primary perivascular cold injury at the right common carotid artery followed by a 1.5% cholesterol-rich diet injury for eight weeks. All of the rabbits' arteries were imaged by B-mode ultrasound weekly, after which the rabbits were sacrificed, and their vessels were processed for histopathology. Ultrasound longitudinal view images from three cardiac cycles were processed by a new computerized analyzing method based on dynamic programming and maximum gradient algorithm for measurement of instantaneous changes in arterial wall thickness and lumen diameter in sequential ultrasound images. Histopathology results showed progressive changes, from the lipid-laden cells and fibrous connective tissue proliferation in neointimal layer, up to the fibro-lipid plaque formation, resulting in vessel wall thickening, remodeling and lumen stenosis. The B-mode ultrasound images and the histologic measurements showed an increase in the mean wall thickness and the lumen area stenosis within eight weeks. Quantitative and morphometric analysis of the mean wall thickness and the lumen area stenosis percentage showed a significant correlation between the B-mode ultrasound and the histological measurements at each time point (R = 0.989 and R = 0.995, p < 0.05, respectively). In conclusion, we successfully produced advanced atherosclerosis in the rabbit carotid artery that is similar to the condition seen in patients. This condition in rabbits can be properly assessed by B-mode ultrasound image processing. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Li, Zhi-Yong; Tan, Felicia P P; Soloperto, Giulia; Wood, Nigel B; Xu, Xiao Y; Gillard, Jonathan H
2015-08-01
The aim of this study is to investigate the blood flow pattern in carotid bifurcation with a high degree of luminal stenosis, combining in vivo magnetic resonance imaging (MRI) and computational fluid dynamics (CFD). A newly developed two-equation transitional model was employed to evaluate wall shear stress (WSS) distribution and pressure drop across the stenosis, which are closely related to plaque vulnerability. A patient with an 80% left carotid stenosis was imaged using high resolution MRI, from which a patient-specific geometry was reconstructed and flow boundary conditions were acquired for CFD simulation. A transitional model was implemented to investigate the flow velocity and WSS distribution in the patient-specific model. The peak time-averaged WSS value of approximately 73 Pa was predicted by the transitional flow model, and the regions of high WSS occurred at the throat of the stenosis. High oscillatory shear index values up to 0.50 were present in a helical flow pattern from the outer wall of the internal carotid artery immediately after the throat. This study shows the potential suitability of a transitional turbulent flow model in capturing the flow phenomena in severely stenosed carotid arteries using patient-specific MRI data and provides the basis for further investigation of the links between haemodynamic variables and plaque vulnerability. It may be useful in the future for risk assessment of patients with carotid disease.
Long, Quan; Luppi, Luca; König, Carola S; Rinaldo, Vittorio; Das, Saroj K
2008-08-28
This numerical study aims to investigate the capacity of the circle of Wills (CoW) to provide collateral blood supply for patients with unilateral carotid arterial stenosis. The basic 3D geometry of the CoW was reconstructed based on a magnetic resonance angiogram of a normal human subject. A total of 52 computational fluid dynamics simulations were performed for four geometry configurations of the CoW with an artificially inserted axisymmetric stenosis of different luminal area reductions in an internal carotid artery (ICA) under a variety of boundary conditions. The CoW geometric configurations included (a) a normal CoW with all communicating arteries; (b) as model (a) but with enlarged communicating arterial diameters; (c) as (a) but with the ipsilateral posterior communicating artery missing, and (d) as (c) but with enlarged communicating arteries. It is found that the blood perfusion pressure drop between the ipsilateral ICA and the middle cerebral artery (MCA) only becomes significant when the degree of stenosis is greater than 86%. The cerebral autoregulation range varied significantly between the different CoW configurations for the severe stenosis cases. Without causing the flow rates to decrease at the efferent arterial ends, the mean perfusion pressure in the ipsilateral ICA can drop from 100 to 73, 67, 92 and 84 mmHg for the CoW models (a)-(d) with 96% luminal area reduction stenosis, respectively. The additional pathways are able to raise the ipsilateral MCA pressure significantly without reducing the total flow perfusion. Cerebral autoregulation effects were not directly included in the study. Therefore, the findings in the study should be interpreted with cautions when comes to the biological and clinical significance.
Takimoto, Y; Okumura, N; Nakamura, T; Natsume, T; Shimizu, Y
1993-01-01
This study investigated ways of preventing late stenosis after replacing the esophagus with a prosthetic device and increasing survival time in an animal model. In a previous study, the authors induced neoesophageal formation and re-epithelialization at an early stage, although stenosis in the chronic stage remained a problem, and long-term survival was prevented. The authors developed an artificial esophagus made from a collagen-silicone composite tube. The silicone tube (25 mm in diameter, 50 mm long, and 1 mm thick) was covered with collagen sponge (5 mm thick). The collagen sponge was intended to be replaced by host tissue, leading to neoesophageal regeneration. The authors thought stenosis was caused primarily by poor regeneration of submucosal tissue, rather than reepithelialization. Thus, they examined the grade of stenosis relative to the time the stent became dislodged. They concluded that the occurrence of stenosis after anastomosis depends upon the duration of stenting and that stenosis did not develop when the portion replaced by the artificial esophagus was stented for at least 4 weeks.
Zhang, Chi; Li, Shuyu; Pu, Fang; Fan, Yubo; Li, Deyu
2014-01-01
The anatomic variation of Circle of Willis (CoW) has great impact on its compensatory capacity during stroke and cerebral ischemia. In the present study, a series of lumped parameter models were developed and used to simulate the effect of postural changes on the cerebral blood flow in ICA stenosis patients with different anatomic variants of the CoW. The results showed that the asymmetric distribution of cerebral blood flow caused by stenosis was attenuated in standing position in complete and half-complete CoW. However, in incomplete CoW, the decrease in blood flow in the ipsilateral cerebral arteries caused by unilateral ICA stenosis was dramatic in both supine and standing positions, a likely result of inadequate collateral circulation within the CoW. In conclusion, the anatomic variation of CoW plays a significant role in maintaining the balance of cerebral blood supply in patients with ICA stenosis, especially during postural change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamaki, N.; Alpert, N.M.; Rabito, C.A.
The sequence and magnitude of acute changes in renal blood flow following administration of captopril were determined in a canine model of acute unilateral renal artery stenosis using rubidium-82 and positron emission tomography. Data were recorded in each of nine dogs under three conditions: 1) during a baseline control interval, 2) during renal artery stenosis, and 3) during stenosis with intravenous injection of captopril (1.2 mg/kg). Mean arterial blood pressure was 108 +/- 12 mm Hg at control, increased significantly to 125 +/- 13 mm Hg (p less than 0.01) during stenosis, and decreased to 98 +/- 13 mm/Hg (pmore » less than 0.01) after captopril infusion. Mean renal blood flow was calculated using a steady state single compartment model from the images produced by positron emission tomography. The estimated flow to the affected kidney was 3.37 +/- 1.48 ml/min/g at control, 0.86 +/- 0.62 ml/min/g during stenosis (p less than 0.01), and 0.64 +/- 0.57 ml/min/g after captopril administration (p = NS compared with precaptopril value). The estimated flow to the contralateral kidney was minimally reduced from a baseline of 3.84 +/- 0.95 to 3.24 +/- 1.13 ml/min/g (p = NS) during stenosis and increased after captopril infusion (4.08 +/- 0.94 ml/min/g; p = 0.01). These data suggest that repetitive imaging with positron emission tomography can be used to delineate acute changes in renal perfusion following captopril administration.« less
Mata, Karina M; Prudente, Paula S; Rocha, Fabio S; Prado, Cibele M; Floriano, Elaine M; Elias, Jorge; Rizzi, Elen; Gerlach, Raquel F; Rossi, Marcos A; Ramos, Simone G
2011-01-01
Progress in understanding the pathophysiology of abdominal aortic aneurysms (AAA) is dependent in part on the development and application of effective animal models that recapitulate key aspects of the disease. The objective was to produce an experimental model of AAA in rats by combining two potential causes of metalloproteinase (MMP) secretion: inflammation and turbulent blood flow. Male Wistar rats were randomly divided in four groups: Injury, Stenosis, Aneurysm and Control (40/group). The Injury group received a traumatic injury to the external aortic wall. The Stenosis group received an extrinsic stenosis at a corresponding location. The Aneurysm group received both the injury and stenosis simultaneously, and the Control group received a sham operation. Animals were euthanized at days 1, 3, 7 and 15. Aorta and/or aneurysms were collected and the fragments were fixed for morphologic, immunohistochemistry and morphometric analyses or frozen for MMP assays. AAAs had developed by day 3 in 60–70% of the animals, reaching an aortic dilatation ratio of more than 300%, exhibiting intense wall remodelling initiated at the adventitia and characterized by an obvious inflammatory infiltrate, mesenchymal proliferation, neoangiogenesis, elastin degradation and collagen deposition. Immunohistochemistry and zymography studies displayed significantly increased expressions of MMP-2 and MMP-9 in aneurysm walls compared to other groups. The haemo-dynamic alterations caused by the stenosis may have provided additional contribution to the MMPs liberation. This new model illustrated that AAA can be multifactorial and confirmed the key roles of MMP-2 and MMP-9 in this dynamic remodelling process. PMID:21039990
Yang, Yu-Shang; Hu, Wei-Peng; Ni, Peng-Zhi; Wang, Wen-Ping; Yuan, Yong; Chen, Long-Qi
2017-01-01
Background Predictive value of preoperative endoscopic characteristic of esophageal tumor has not been fully evaluated. The aim of this study is to investigate the impact of esophageal luminal stenosis on survival for patients with resectable esophageal squamous cell carcinoma (ESCC). Methods The clinicopathologic characteristics of 623 ESCC patients who underwent curative resection as the primary treatment between January 2005 and April 2009 were retrospectively reviewed. The esophageal luminal stenosis measured by endoscopy was defined as a uniform measurement preoperatively. The impact of esophageal luminal stenosis on patients’ overall survival (OS) and relation with other clinicopathological features were assessed. A Cox regression model was used to identify prognostic factors. Results The results showed that OS significantly decreased in patients with manifest stenotic tumor compared with patients without luminal obstruction (P<0.05). Considerable esophageal luminal stenosis was associated with a higher T stage, longer tumor length, and poorer differentiation (all P<0.05). In multivariate survival analysis, esophageal luminal stenosis remained as an independent prognostic factor for OS (P= 0.036). Conclusions Esophageal luminal stenosis could have a significant impact on the OS in patients with resected ESCC and may provide additional prognostic value to the current staging system before any cancer-specific treatment. PMID:28118615
Abdollahzadeh Jamalabadi, Mohammad Yaghoub; Daqiqshirazi, Mohammadreza; Nasiri, Hossein; Nguyen, Truong Khang
2018-01-01
We present a numerical investigation of tapered arteries that addresses the transient simulation of non-Newtonian bio-magnetic fluid dynamics (BFD) of blood through a stenosis artery in the presence of a transverse magnetic field. The current model is consistent with ferro-hydrodynamic (FHD) and magneto-hydrodynamic (MHD) principles. In the present work, blood in small arteries is analyzed using the Carreau-Yasuda model. The arterial wall is assumed to be fixed with cosine geometry for the stenosis. A parametric study was conducted to reveal the effects of the stenosis intensity and the Hartman number on a wide range of flow parameters, such as the flow velocity, temperature, and wall shear stress. Current findings are in a good agreement with recent findings in previous research studies. The results show that wall temperature control can keep the blood in its ideal blood temperature range (below 40°C) and that a severe pressure drop occurs for blockages of more than 60 percent. Additionally, with an increase in the Ha number, a velocity drop in the blood vessel is experienced. PMID:29489852
Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion
Das, Marco; Haberland, Ulrike; Slump, Cees; Handayani, Astri; van Tuijl, Sjoerd; Stijnen, Marco; Oudkerk, Matthijs; Wildberger, Joachim E.; Vliegenthart, Rozemarijn
2015-01-01
Objective. To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experiment. Stenosis was induced in the circumflex artery, controlled by a fractional flow reserve (FFR) pressure wire. CT-derived myocardial perfusion parameters were analysed at FFR of 1 to 0.10/0.0. Results. CT images did not show major artefacts due to interference of the model setup. The pacemaker-induced heart rhythm was generally stable at 70 beats per minute. During most of the experiment, blood flow was 0.9–1.0 L/min, and arterial pressure varied between 80 and 95 mm/Hg. Blood flow decreased and arterial pressure increased by approximately 10% after inducing a stenosis with FFR ≤ 0.50. Dynamic perfusion scanning was possible across the range of stenosis grades. Perfusion parameters of circumflex-perfused myocardial segments were affected at increasing stenosis grades. Conclusion. An adapted Langendorff porcine heart model is feasible in a CT environment. This model provides control over physiological parameters and may allow in-depth validation of quantitative CT perfusion techniques. PMID:26185756
... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...
Cheng, Shaokoon; Fletcher, David; Hemley, Sarah; Stoodley, Marcus; Bilston, Lynne
2014-08-22
It is unknown whether spinal cord motion has a significant effect on cerebrospinal fluid (CSF) pressure and therefore the importance of including fluid structure interaction (FSI) in computational fluid dynamics models (CFD) of the spinal subarachnoid space (SAS) is unclear. This study aims to determine the effects of FSI on CSF pressure and spinal cord motion in a normal and in a stenosis model of the SAS. A three-dimensional patient specific model of the SAS and spinal cord were constructed from MR anatomical images and CSF flow rate measurements obtained from a healthy human being. The area of SAS at spinal level T4 was constricted by 20% to represent the stenosis model. FSI simulations in both models were performed by running ANSYS CFX and ANSYS Mechanical in tandem. Results from this study show that the effect of FSI on CSF pressure is only about 1% in both the normal and stenosis models and therefore show that FSI has a negligible effect on CSF pressure. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Pelz, Johann Otto; Weinreich, Anna; Karlas, Thomas; Saur, Dorothee
2017-01-01
Currently, colour-coded duplex sonography (2D-CDS) is clinical standard for detection and grading of internal carotid artery stenosis (ICAS). However, unlike angiographic imaging modalities, 2D-CDS assesses ICAS by its hemodynamic effects rather than luminal changes. Aim of this study was to evaluate freehand 3D ultrasound (3DUS) for direct visualisation and quantification of ICAS. Thirty-seven patients with 43 ICAS were examined with 2D-CDS as reference standard and with freehand B-mode respectively power-mode 3DUS. Stenotic value of 3D reconstructed ICAS was calculated as distal diameter respectively distal cross-sectional area (CSA) reduction percentage and compared with 2D-CDS. There was a trend but no significant difference in successful 3D reconstruction of ICAS between B-mode and power mode (examiner 1 {Ex1} 81% versus 93%, examiner 2 {Ex2} 84% versus 88%). Inter-rater agreement was best for power-mode 3DUS and assessment of stenotic value as distal CSA reduction percentage (intraclass correlation coefficient {ICC} 0.90) followed by power-mode 3DUS and distal diameter reduction percentage (ICC 0.81). Inter-rater agreement was poor for B-mode 3DUS (ICC, distal CSA reduction 0.36, distal diameter reduction 0.51). Intra-rater agreement for power-mode 3DUS was good for both measuring methods (ICC, distal CSA reduction 0.88 {Ex1} and 0.78 {Ex2}; ICC, distal diameter reduction 0.83 {Ex1} and 0.76 {Ex2}). In comparison to 2D-CDS inter-method agreement was good and clearly better for power-mode 3DUS (ICC, distal diameter reduction percentage: Ex1 0.85, Ex2 0.78; distal CSA reduction percentage: Ex1 0.63, Ex2 0.57) than for B-mode 3DUS (ICC, distal diameter reduction percentage: Ex1 0.40, Ex2 0.52; distal CSA reduction percentage: Ex1 0.15, Ex2 0.51). Non-invasive power-mode 3DUS is superior to B-mode 3DUS for imaging and quantification of ICAS. Thereby, further studies are warranted which should now compare power-mode 3DUS with the angiographic gold standard imaging modalities for quantification of ICAS, i.e. with CTA or CE-MRA.
NASA Astrophysics Data System (ADS)
Patel, Shivam; Usmani, Abdullah Y.; Muralidhar, K.
2017-06-01
Physiological flows in rigid diseased arterial flow phantoms emulating an abdominal aortic aneurysm (AAA) under rest conditions with aorto-iliac bifurcation and iliac stenosis are examined in vitro through 2D PIV measurements. Flow characteristics are first established in the model resembling a symmetric AAA with a straight outlet tube. The influence of aorto-iliac bifurcation and iliac stenosis on AAA flow dynamics is then explored through a comparison of the nature of flow patterns, vorticity evolution, vortex core trajectory and hemodynamic factors against the reference configuration. Specifically, wall shear stress and oscillatory shear index in the bulge portion of the models are of interest. The results of this investigation indicate overall phenomenological similarity in AAA flow patterns across the models. The pattern is characterized by a central jet and wall-bounded vortices whose strength increases during the deceleration phase as it moves forward. The central jet impacts the wall of AAA at its distal end. In the presence of an aorto-iliac bifurcation as well as iliac stenosis, the flow patterns show diminished strength, expanse and speed of propagation of the primary vortices. The positions of the instantaneous vortex cores, determined using the Q-function, correlate with flow separation in the bulge, flow resistance due to a bifurcation, and the break in symmetry introduced by a stenosis in one of the legs of the model. Time-averaged WSS in a healthy aorta is around 0.70 N m-2 and is lowered to the range ±0.2 N m-2 in the presence of the downstream bifurcation with a stenosed common iliac artery. The consequence of changes in the flow pattern within the aneurysm on disease progression is discussed.
Factors associated with atrial fibrillation in rheumatic mitral stenosis.
Pourafkari, Leili; Ghaffari, Samad; Bancroft, George R; Tajlil, Arezou; Nader, Nader D
2015-01-01
Atrial fibrillation is a complication of mitral valve stenosis that causes several adverse neurologic outcomes. Our objective was to establish a mathematical model to predict the risk of atrial fibrillation in patients with mitral stenosis. Of 819 patients with mitral stenosis who were screened, 603 were enrolled in the study and grouped according to whether they were in sinus rhythm or atrial fibrillation. Demographic, echocardiographic, and hemodynamic data were recorded. Logistic regression models were constructed to identify the relative risks for each contributing factor and calculate the probability of developing atrial fibrillation. Receiver operating characteristic curves were plotted. Two hundred (33%) patients had atrial fibrillation; this group was older, in a higher functional class, more likely to have suffered previous thromboembolic events, and had significantly larger left atrial diameters, lower ejection fractions, and lower left atrial appendage emptying flow velocity. The factors independently associated with atrial fibrillation were left atrial strain (odds ratio = 7.53 [4.47-12.69], p < 0.001), right atrial pressure (odds ratio = 1.09 [1.02-1.17], p = 0.01), age (odds ratio = 1.14 [1.05-1.25], p = 0.002), and ejection fraction (odds ratio = 0.92 [0.87-0.97], p = 0.003). The area under the curve for the combined receiver operating characteristic for this model was 0.90 ± 0.12. Age, right atrial pressure, ejection fraction, and left atrial strain can be used to construct a mathematical model to predict the development of atrial fibrillation in rheumatic mitral stenosis. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Comparison of different models for non-invasive FFR estimation
NASA Astrophysics Data System (ADS)
Mirramezani, Mehran; Shadden, Shawn
2017-11-01
Coronary artery disease is a leading cause of death worldwide. Fractional flow reserve (FFR), derived from invasively measuring the pressure drop across a stenosis, is considered the gold standard to diagnose disease severity and need for treatment. Non-invasive estimation of FFR has gained recent attention for its potential to reduce patient risk and procedural cost versus invasive FFR measurement. Non-invasive FFR can be obtained by using image-based computational fluid dynamics to simulate blood flow and pressure in a patient-specific coronary model. However, 3D simulations require extensive effort for model construction and numerical computation, which limits their routine use. In this study we compare (ordered by increasing computational cost/complexity): reduced-order algebraic models of pressure drop across a stenosis; 1D, 2D (multiring) and 3D CFD models; as well as 3D FSI for the computation of FFR in idealized and patient-specific stenosis geometries. We demonstrate the ability of an appropriate reduced order algebraic model to closely predict FFR when compared to FFR from a full 3D simulation. This work was supported by the NIH, Grant No. R01-HL103419.
Pulsatile spiral blood flow through arterial stenosis.
Linge, Fabian; Hye, Md Abdul; Paul, Manosh C
2014-11-01
Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.
Swillens, Abigail; De Witte, Marloes; Nordgaard, Håvard; Løvstakken, Lasse; Van Loo, Denis; Trachet, Bram; Vierendeels, Jan; Segers, Patrick
2012-08-01
The long-term patency of the left internal mammary artery (LIMA) in left anterior descending (LAD) coronary stenosis bypass surgery is believed to be related to the degree of competitive flow between the LAD and LIMA. To investigate the effect of the LAD stenosis severity on this phenomenon and on haemodynamics in the LIMA and anastomosis region, a numerical LIMA-LAD model was developed based on 3D geometric (obtained from a cast) and hemodynamic data from an experimental pig study. Proximal LAD pressure was used as upstream boundary condition. The model counted 13 outlets (12 septal arteries and the distal LAD) where flow velocities were imposed in systole, while myocardial conductance was imposed in diastole via an implicit scheme. LAD stenoses of 100 (total occlusion), 90, 75 and 0 % area reduction were constructed. Low degree of LAD stenosis was associated with highly competitive flow and low wall shear stress (WSS) in the LIMA, an unfavourable hemodynamic regime which might contribute to WSS-related remodelling of the LIMA and suboptimal long-term LIMA bypass performance.
Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K
2009-01-01
Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis
Shirakawa, Takashi; Yoshitatsu, Masao; Koyama, Yasushi; Mizoguchi, Hiroki; Toda, Koichi; Sawa, Yoshiki
2018-05-14
Surgical simulation devices can be helpful and cost-effective adjuncts to on-the-job training. In this tutorial we present our method for creating an aortic stenosis model with realistically fragile and crushable calcifications, using modern 3D-printing techniques. The model can be used for training and surgical simulation and is an effective aid to learning for young cardiovascular surgeons. © The Author 2016. Published by MMCTS on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Tubbs, Kyle J; Silva, Rodrigo C; Ramirez, Harvey E; Castleman, William L; Collins, William O
2013-01-01
Balloon dilation is accepted as a first line treatment of acute subglottic stenosis, but its effects on the subglottic tissue remain largely unknown. We aimed to develop an animal model of acute subglottic stenosis using endoscopic techniques. Once developed, this model was used to compare the immediate effects of balloon dilation and endotracheal tube dilation on subglottic tissue. Prospective randomized animal study. Acute subglottic injury was induced in 10 ferrets by endoscopic cauterization with silver nitrate. After 48-72 hours of observation, eight animals were randomized to undergo subglottic dilation with either a 5-mm balloon or endotracheal tubes of increasing diameter. These eight ferrets were euthanized within 10 minutes after dilation. The other two ferrets served as controls and were euthanized following observation only. The larynx from each ferret was harvested, and the subglottis was examined histologically by a pathologist blinded to the treatment arms. Acute subglottic stenosis was induced in all 10 ferrets using the endoscopic technique. Both balloon and endotracheal tube dilation resulted in comparable improvement in the subglottic airway diameter. A decreased thickness of submucosa/lamina propria was seen in the balloon dilation group. Acute subglottic stenosis can be reliably induced in ferrets using endoscopic techniques. Multiple dilation methods can be used to relieve acute obstruction. Balloon dilators seem to improve airway patency, in part, by decreasing the thickness of the submucosa and lamina propria. Further research is needed to determine how this impacts later stages of wound healing and final outcomes. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Sampaio, Francisco; Ladeiras-Lopes, Ricardo; Almeida, João; Fonseca, Paulo; Fontes-Carvalho, Ricardo; Ribeiro, José; Gama, Vasco
2017-07-01
Management of patients with mitral stenosis (MS) depends heavily on the accurate quantification of mitral valve area (MVA) using echocardiography. All currently used two-dimensional (2D) methods have limitations. Estimation of MVA using the proximal isovelocity surface area (PISA) method with real time three-dimensional (3D) echocardiography may circumvent those limitations. We aimed to evaluate the accuracy of 3D direct measurement of PISA in the estimation of MVA. Twenty-seven consecutive patients (median age of 63 years; 77.8% females) with rheumatic MS were prospectively studied. Transthoracic and transesophageal echocardiography with 2D and 3D acquisitions were performed on the same day. The reference method for MVA quantification was valve planimetry after 3D-volume multiplanar reconstruction. A semi-automated software was used to calculate the 3D flow convergence volume. Compared to MVA estimation using 3D planimetry, 3D PISA showed the best correlation (rho=0.78, P<.0001), followed by pressure half-time (PHT: rho=0.66, P<.001), continuity equation (CE: rho=0.61, P=.003), and 2D PISA (rho=0.26, P=.203). Bland-Altman analysis revealed a good agreement for MVA estimation with 3D PISA (mean difference -0.03 cm 2 ; limits of agreement (LOA) -0.40-0.35), in contrast to wider LOA for 2D methods: CE (mean difference 0.02 cm 2 , LOA -0.56-0.60); PHT (mean difference 0.31 cm 2 , LOA -0.32-0.95); 2D PISA (mean difference -0.03 cm 2 , LOA -0.92-0.86). MVA estimation using 3D PISA was feasible and more accurate than 2D methods. Its introduction in daily clinical practice seems possible and may overcome technical limitations of 2D methods. © 2017, Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang, Y; Huang, H; Su, T
Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCImore » Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination of the myocardial ischemia.« less
Bandula, Steve; White, Steven K; Flett, Andrew S; Lawrence, David; Pugliese, Francesca; Ashworth, Michael T; Punwani, Shonit; Taylor, Stuart A; Moon, James C
2013-11-01
To develop and validate equilibrium contrast material-enhanced computed tomography (CT) to measure myocardial extracellular volume (ECV) fraction by using a histologic reference standard and to compare equilibrium CT with equilibrium contrast-enhanced magnetic resonance (MR) imaging. A local ethics committee approved the study, and all subjects gave fully informed written consent. An equilibrium CT protocol was developed using iohexol at 300 mg of iodine per milliliter (bolus of 1 mg per kilogram of body weight administered at a rate of 3 mL/sec, followed immediately by an infusion of 1.88 mL/kg per hour with CT imaging before and at 25 minutes after injection of bolus of contrast agent) and ECV within the myocardial septum measured using both equilibrium CT and equilibrium MR imaging in patients with severe aortic stenosis. Biopsy samples of the myocardial septum collected during valve replacement surgery were used for histologic quantification of extracellular fibrosis with picrosirius red staining. Equilibrium CT- and equilibrium MR imaging-derived ECV measurements were compared with histologically quantified fibrosis by using Pearson correlation. Agreement between equilibrium CT and equilibrium MR imaging was assessed by using Bland-Altman comparison. Twenty-three patients (16 male, seven female; mean age, 70.8 years; standard deviation, 8.3) were recruited. The mean percentage of histologic fibrosis was 18% (intersubject range, 5%-40%). There was a significant correlation between both equilibrium CT- and equilibrium MR imaging-derived ECV and percentage of histologic fibrosis (r = 0.71 [P < .001] and r = 0.84 [P < .0001], respectively). Equilibrium CT-derived ECV was significantly correlated to equilibrium MR imaging-derived ECV (r = 0.73). ECV measured by using equilibrium CT in patients with aortic stenosis correlates with histologic quantification of myocardial fibrosis and with ECV derived by using equilibrium MR imaging. RSNA, 2013
Protective effect of active perfusion in porcine models of acute myocardial ischemia
Feng, Zanxiang; Mao, Zhifu; Dong, Shengjun; Liu, Baohui
2016-01-01
Mortality rates associated with off-pump coronary artery bypass (CAB) are relatively high, as the majority of patients requiring CAB are at a high risk for cardiac events. The present study aimed to establish porcine models of acute myocardial ischemia, and evaluate the protective role of shunt and active perfusion. A total of 30 pigs were randomly assigned to five groups, as follows: i) Sham (control); ii) A1 (shunt; stenosis rate, 55%); iii) A2 (shunt; stenosis rate, 75%); iv) B1 (active perfusion; stenosis rate, 55%); and v) B2 (active perfusion; stenosis rate, 75%) groups. Aortic pressure (P0), left anterior descending coronary pressure (P1), and coronary effective perfusion pressure (P1/P0) were measured. The expression levels of tumor necrosis factor-α (TNF-α), cardiac troponin (cTnI), creatine kinase-myocardial band (CK-MB), interleukin (IL)-6, IL-10, B-cell lymphoma 2 (Bcl-2), and caspase-3 were detected using enzyme-linked immunosorbent assay or western blotting. The myocardial apoptosis rate was determined using the terminal deoxynucleotidyl transferase dUTP nick end labeling assay. Ischemia models with stenosis rates of 55 and 75% were successfully constructed following suturing of the descending artery. Compared with the control, the 55 and 75% stenosis groups demonstrated significantly decreased P1/P0, increased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, an increased rate of myocardial apoptosis, and a decreased expression level of anti-apoptotic protein, Bcl-2. At 30 min following successful establishment of the model (ST segment elevation to 1 mm), group B demonstrated significantly increased P1/P0, decreased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, a decreased rate of myocardial apoptosis, and an increased expression level of anti-apoptotic protein, Bcl-2. Furthermore, the current study indicated that active perfusion was more efficacious in maintaining myocardial perfusion and alleviating ischemic injury when compared with traditional shunt perfusion. PMID:27573177
Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A; Osman, Nael F
2009-03-01
High-dose dobutamine stress MRI is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, strain-encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC with that provided by conventional wall motion analysis for the detection of inducible ischemia during dobutamine stress MRI. Stress-induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent dobutamine stress MRI in a clinical 1.5-T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (> or =50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86 of 101 versus 71 of 101 diseased coronary vessels (P<0.01 versus cine) and showed normal strain response in 189 of 202 versus 194 of 202 vessels with <50% stenosis (P=NS versus cine). On a patient level, SENC detected inducible ischemia in 63 of 64 versus 55 of 64 patients with CAD (P<0.05 versus cine) and showed normal strain response in 32 of 37 versus 34 of 37 patients without CAD (P=NS versus cine). Quantification analysis demonstrated a significant correlation between strain rate reserve and coronary artery stenosis severity (r(2)=0.56, P<0.001), and a cutoff value of strain rate reserve of 1.64 was deemed as a highly accurate marker for the detection of > or =50% stenosis (area under the curve, 0.96; SE, 0.01; 95% CI, 0.94 to 0.98; P<0.001). The direct color-coded visualization of strain on MR images is a useful adjunct for dobutamine stress MRI, which provides incremental value for the detection of CAD compared with conventional wall motion readings on cine images.
Hemodynamics of Aortic Stenosis and Implications for Non-invasive Diagnosis via Auscultation
NASA Astrophysics Data System (ADS)
Zhu, Chi; Seo, Jung-Hee; Mittal, Rajat
2017-11-01
Aortic stenosis refers to the abnormal narrowing of the aortic valve and it is one of the most common valvular diseases. It is also known to generate ejection murmurs, which contain valuable disease-related information. However, an incomplete understanding of the flow mechanism(s) responsible for the murmur generation, as well as the effect of intervening tissue on murmur propagation has limited the diagnostic information can be extracted through cardiac auscultation. In this study, a canonical model of the aorta with stenosis is used, and a multiphysics computational modeling approach is employed to investigate the generation and propagation of the murmurs. First, direct numerical simulation (DNS) is used to explore the hemodynamics of the post-stenotic flow. Then, a high-order, linear viscoelastic wave solver is used to investigate the wave propagation in a modeled thorax. The results show that both the aortic jet and the secondary flow contribute significantly to the murmur generation. The murmur signals on the epidermal surface are measured and analyzed. The break frequencies obtained from the spectra of cases with different degrees of stenosis are found to follow a universal scaling. The implications of these results for cardiac auscultation are discussed. The authors would like to acknowledge support from NSF Grants IIS-1344772, CBET-1511200, and NSF XSEDE Grant TG-CTS100002.
Martins, Jumara; Vaz, Ana Francisca; Grion, Regina Celia; Esteves, Sérgio Carlos Barros; Costa-Paiva, Lúcia; Baccaro, Luiz Francisco
2017-12-01
This study reports the incidence and factors associated with vaginal stenosis and changes in vaginal dimensions after pelvic radiotherapy for cervical cancer. A descriptive longitudinal study with 139 women with cervical cancer was conducted from January 2013 to November 2015. The outcome variables were vaginal stenosis assessed using the Common Terminology Criteria for Adverse Events (CTCAE v3.0) and changes in vaginal diameter and length after the end of radiotherapy. Independent variables were the characteristics of the neoplasm, clinical and sociodemographic data. Bivariate analysis was carried out using χ 2 , Kruskal-Wallis and Mann-Whitney's test. Multiple analysis was carried out using Poisson regression and a generalized linear model. Most women (50.4%) had stage IIIB tumors. According to CTCAE v3.0 scale, 30.2% had no stenosis, 69.1% had grade 1 and 0.7% had grade 2 stenosis after radiotherapy. Regarding changes in vaginal measures, the mean variation in diameter was - 0.6 (± 1.7) mm and the mean variation in length was - 0.6 (± 1.3) cm. In the final statistical model, having tumoral invasion of the vaginal walls (coefficient + 0.73, p < 0.01) and diabetes (coefficient + 1.16; p < 0.01) were associated with lower vaginal stenosis and lower reduction of vaginal dimensions. Advanced clinical stage (coefficient + 1.44; p = 0.02) and receiving brachytherapy/teletherapy (coefficient - 1.17, p < 0.01) were associated with higher reduction of vaginal dimensions. Most women had mild vaginal stenosis with slight reductions in both diameter and length of the vaginal canal. Women with tumoral invasion of the vagina have an increase in vaginal length soon after radiotherapy due to a reduction in tumoral volume.
Mathematical modeling of pulsatile flow of non-Newtonian fluid in stenosed arteries
NASA Astrophysics Data System (ADS)
Sankar, D. S.; Lee, Usik
2009-07-01
The pulsatile flow of blood through mild stenosed artery is studied. The effects of pulsatility, stenosis and non-Newtonian behavior of blood, treating the blood as Herschel-Bulkley fluid, are simultaneously considered. A perturbation method is used to analyze the flow. The expressions for the shear stress, velocity, flow rate, wall shear stress, longitudinal impedance and the plug core radius have been obtained. The variations of these flow quantities with different parameters of the fluid have been analyzed. It is found that, the plug core radius, pressure drop and wall shear stress increase with the increase of yield stress or the stenosis height. The velocity and the wall shear stress increase considerably with the increase in the amplitude of the pressure drop. It is clear that for a given value of stenosis height and for the increasing values of the stenosis shape parameter from 3 to 6, there is a sharp increase in the impedance of the flow and also the plots are skewed to the right-hand side. It is observed that the estimates of the increase in the longitudinal impedance increase with the increase of the axial distance or with the increase of the stenosis height. The present study also brings out the effects of asymmetric of the stenosis on the flow quantities.
Positron emission tomography of the vulnerable atherosclerotic plaque in man – a contemporary review
Pedersen, Sune F; Hag, Anne Mette F; Klausen, Thomas L; Ripa, Rasmus S; Bodholdt, Rasmus P; Kjær, Andreas
2014-01-01
Atherosclerosis is the primary underlying cause of cardiovascular disease (CVD). It is the leading cause of morbidity and mortality in the Western world today and is set to become the prevailing disease and major cause of death worldwide by 2020. In the 1950s surgical intervention was introduced to treat symptomatic patients with high-grade carotid artery stenosis due to atherosclerosis – a procedure known as carotid endarterectomy (CEA). By removing the atherosclerotic plaque from the affected carotid artery of these patients, CEA is beneficial by preventing subsequent ipsilateral ischemic stroke. However, it is known that patients with low to intermediate artery stenosis may still experience ischemic events, leading clinicians to consider plaque composition as an important feature of atherosclerosis. Today molecular imaging can be used for characterization, visualization and quantification of cellular and subcellular physiological processes as they take place in vivo; using this technology we can obtain valuable information on atherosclerostic plaque composition. Applying molecular imaging clinically to atherosclerotic disease therefore has the potential to identify atherosclerotic plaques vulnerable to rupture. This could prove to be an important tool for the selection of patients for CEA surgery in a health system increasingly focused on individualized treatment. This review focuses on current advances and future developments of in vivo atherosclerosis PET imaging in man. PMID:24289282
Brunetti, Natale Daniele; Delli Carri, Felice; Ruggiero, Maria Assunta; Cuculo, Andrea; Ruggiero, Antonio; Ziccardi, Luigi; De Gennaro, Luisa; Di Biase, Matteo
2014-03-01
Exact quantification of plaque extension during coronary angioplasty (PCI) usually falls on interventional cardiologist (IC). Quantitative coronary stenosis assessment (QCA) may be possibly committed to the radiology technician (RT), who usually supports cath-lab nurse and IC during PCI. We therefore sought to investigate the reliability of QCA performed by RT in comparison with IC. Forty-four consecutive patients with acute coronary syndrome underwent PCI; target coronary vessel size beneath target coronary lesion (S) and target coronary lesion length (L) were assessed by the RT, junior IC (JIC), and senior IC (SIC) and then compared. SIC evaluation, which determined the final stent selection for coronary stenting, was considered as a reference benchmark. RT performance with QCA support in assessing target vessel size and target lesion length was not significantly different from SIC (r = 0.46, p < 0.01; r = 0.64, p < 0.001, respectively) as well as JIC (r = 0.79, r = 0.75, p < 0.001, respectively). JIC performance was significantly better than RT in assessing target vessel size (p < 0.05), while not significant when assessing target lesion length. RT may reliably assess target lesion by using adequate QCA software in the cath-lab in case of PCI; RT performance does not differ from SIC.
FFR analysis of blood flow through a stenosed Left Anterior Descending Artery
NASA Astrophysics Data System (ADS)
Pasupathi, Jawahar; Arul Prakash, K.
2017-11-01
The numerical analyisis of blood flow through a stenosed tapering Left Anterior Descending (LAD) artery was done using Streamwise Upwind Petrov Galerkin (SUPG) method to obtain the clinical parameters such as Fractional Flow reserve (FFR) and Wall Shear Stress (WSS). The geometry was considered to be a straight tapering cylindrical duct with the severity of stenosis modeled using a curve equation based on the reduction in diameter at the stenosed region. Poiseuille velocity profile was given at the inlet such that at each time step the product of mean velocity and the inlet area gives the realistic flow rate through the LAD. The simulation was done for 30,50 and 70 percent reduction in cross-section of LAD. The average pressure values across the stenosis was used to quantify FFR. The FFR increased with higher pressure ratio across the stenosis, which is a result of increased severity of stenosis. The velocity gradients that are responsible for the shear stress at the walls were found to be dependent on the shape of the stenosis, i.e., the diameter and its length.
Common iliac vein stenosis and risk of symptomatic pulmonary embolism: an inverse correlation.
Chan, Keith T; Popat, Rita A; Sze, Daniel Y; Kuo, William T; Kothary, Nishita; Louie, John D; Hovsepian, David M; Hwang, Gloria L; Hofmann, Lawrence V
2011-02-01
To test the hypothesis that a common iliac vein (CIV) stenosis may impair embolization of a large deep venous thrombosis (DVT) to the lungs, decreasing the incidence of a symptomatic pulmonary embolism (PE). Between January 2002 and August 2007, 75 patients diagnosed with unilateral DVT were included in a single-institution case-control study. Minimum CIV diameters were measured 1 cm below the inferior vena cava (IVC) bifurcation on computed tomography (CT) images. A significant stenosis in the CIV ipsilateral to the DVT was defined as having either a diameter 4 mm or less or a greater than 70% reduction in lumen diameter. A symptomatic PE was defined as having symptoms and imaging findings consistent with a PE. The odds of symptomatic PE versus CIV stenosis were assessed using logistic regression models. The associations between thrombus location, stenosis, and symptomatic PE were assessed using a stratified analysis. Of 75 subjects, 49 (65%) presented with symptomatic PE. There were 17 (23%) subjects with a venous lumen 4 mm or less and 12 (16%) subjects with a greater than 70% stenosis. CIV stenosis of 4 mm or less resulted in a decreased odds of a symptomatic PE compared with a lumen greater than 4 mm (odds ratio [OR] 0.17, P = .011), whereas a greater than 70% stenosis increased the odds of DVT involving the CIV (OR 7.1, P = .047). Among patients with unilateral DVT, those with an ipsilateral CIV lumen of 4 mm or less have an 83% lower risk of developing symptomatic PE compared with patients with a CIV lumen greater than 4 mm. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Tu, Shengxian; Echavarria-Pinto, Mauro; von Birgelen, Clemens; Holm, Niels R; Pyxaras, Stylianos A; Kumsars, Indulis; Lam, Ming Kai; Valkenburg, Ilona; Toth, Gabor G; Li, Yingguang; Escaned, Javier; Wijns, William; Reiber, Johan H C
2015-04-20
The aim of this study was to develop a new model for assessment of stenosis severity in a bifurcation lesion including its core. The diagnostic performance of this model, powered by 3-dimensional quantitative coronary angiography to predict the functional significance of obstructive bifurcation stenoses, was evaluated using fractional flow reserve (FFR) as the reference standard. Development of advanced quantitative models might help to establish a relationship between bifurcation anatomy and FFR. Patients who had undergone coronary angiography and interventions in 5 European cardiology centers were randomly selected and analyzed. Different bifurcation fractal laws, including Murray, Finet, and HK laws, were implemented in the bifurcation model, resulting in different degrees of stenosis severity. A total of 78 bifurcation lesions in 73 patients were analyzed. In 51 (65%) bifurcations, FFR was measured in the main vessel. A total of 34 (43.6%) interrogated vessels had an FFR≤0.80. Correlation between FFR and diameter stenosis was poor by conventional straight analysis (ρ=-0.23, p<0.001) but significantly improved by bifurcation analyses: the highest by the HK law (ρ=-0.50, p<0.001), followed by the Finet law (ρ=-0.49, p<0.001), and the Murray law (ρ=-0.41, p<0.001). The area under the receiver-operating characteristics curve for predicting FFR≤0.80 was significantly higher by bifurcation analysis compared with straight analysis: 0.72 (95% confidence interval: 0.61 to 0.82) versus 0.60 (95% confidence interval: 0.49 to 0.71; p=0.001). Applying a threshold of ≥50% diameter stenosis, as assessed by the bifurcation model, to predict FFR≤0.80 resulted in 23 true positives, 27 true negatives, 17 false positives, and 11 false negatives. The new bifurcation model provides a comprehensive assessment of bifurcation anatomy. Compared with straight analysis, identification of lesions with preserved FFR values in obstructive bifurcation stenoses was improved. Nevertheless, accuracy was limited by using solely anatomical parameters. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Tsukada, Jitsuro; Yamada, Minoru; Yamada, Yoshitake; Yamazaki, Shun; Imanishi, Nobuaki; Tamura, Kentaro; Hashimoto, Masahiro; Nakatsuka, Seishi; Jinzaki, Masahiro
2016-07-01
To investigate whether adaptive statistical iterative reconstruction (ASiR) or model-based iterative reconstruction (MBIR) improves the diagnostic performance of computed tomography angiography (CTA) for small-vessel calcified lesions relative to filtered back projection (FBP) using cadaver extremities and a calcified stenosis phantom. A cadaver was used in accordance with our institutional regulations, and a calcified stenosis phantom simulating 4 grades of stenosis was prepared. The phantom was inserted within the distal superficial femoral artery of the cadaver leg. Ten CT images per reconstruction type and stenosis grade were acquired using a 64-slice multidetector-row CTA.As an objective measurement, the first and second derivatives of the CT value function profiles were calculated. As a subjective measurement, 2 blinded reviewers measured the stenosis ratio using a quantitative scale. The Wilcoxon rank-sum test was used to evaluate the data. Objective measurements of both 25% and 50% stenosis differed significantly (P < 0.01) between MBIR (25/50%: 25.80/50.30 ± 3.88/3.86%) and FBP (25/50%: 35.60/83.80 ± 3.44/26.10%), whereas significant differences were not observed between ASiR and FBP.Reviewer 2's subjective measurements of 25% stenosis differed significantly (P < 0.01) between MBIR (35.13 ± 3.25%) and ASiR (40.89 ± 3.14%), and the measurements of 50% stenosis differed significantly (P < 0.01) between MBIR (reviewers 1/2, 62.36/54.78 ± 2.78/4.96%) and FBP (reviewers 1/2, 62.36/74.84 ± 2.78/18.10%). Significant differences in the subjective measurements were not observed between ASiR and FBP. MBIR improves the diagnostic performance of CTA for small-vessel calcified lesions relative to FBP.
Tsukada, Jitsuro; Yamada, Minoru; Yamada, Yoshitake; Yamazaki, Shun; Imanishi, Nobuaki; Tamura, Kentaro; Hashimoto, Masahiro; Nakatsuka, Seishi; Jinzaki, Masahiro
2016-01-01
Abstract Purpose: To investigate whether adaptive statistical iterative reconstruction (ASiR) or model-based iterative reconstruction (MBIR) improves the diagnostic performance of computed tomography angiography (CTA) for small-vessel calcified lesions relative to filtered back projection (FBP) using cadaver extremities and a calcified stenosis phantom. Methods: A cadaver was used in accordance with our institutional regulations, and a calcified stenosis phantom simulating 4 grades of stenosis was prepared. The phantom was inserted within the distal superficial femoral artery of the cadaver leg. Ten CT images per reconstruction type and stenosis grade were acquired using a 64-slice multidetector-row CTA. As an objective measurement, the first and second derivatives of the CT value function profiles were calculated. As a subjective measurement, 2 blinded reviewers measured the stenosis ratio using a quantitative scale. The Wilcoxon rank-sum test was used to evaluate the data. Results: Objective measurements of both 25% and 50% stenosis differed significantly (P < 0.01) between MBIR (25/50%: 25.80/50.30 ± 3.88/3.86%) and FBP (25/50%: 35.60/83.80 ± 3.44/26.10%), whereas significant differences were not observed between ASiR and FBP. Reviewer 2's subjective measurements of 25% stenosis differed significantly (P < 0.01) between MBIR (35.13 ± 3.25%) and ASiR (40.89 ± 3.14%), and the measurements of 50% stenosis differed significantly (P < 0.01) between MBIR (reviewers 1/2, 62.36/54.78 ± 2.78/4.96%) and FBP (reviewers 1/2, 62.36/74.84 ± 2.78/18.10%). Significant differences in the subjective measurements were not observed between ASiR and FBP. Conclusion: MBIR improves the diagnostic performance of CTA for small-vessel calcified lesions relative to FBP. PMID:27399123
Chabasse, Christine; Siefert, Suzanne A.; Chaudry, Mohammed; Hoofnagle, Mark H.; Lal, Brajesh K.; Sarkar, Rajabrata
2016-01-01
Objective We examined the role of thrombus recanalization and ongoing blood flow in the process of thrombus resolution by comparing two murine in vivo models of deep venous thrombosis. Design of study In CD1 mice, we performed surgical inferior vena cava (IVC) ligation (stasis thrombosis), stenosis (thrombosis with recanalization) or sham procedure. We analyzed thrombus weight over time as a measure of thrombus resolution, and quantified the mRNA and protein levels of Membrane-Type Matrix Metalloproteinases (MT-MMPs) as well as effectors of the plasmin complex at day 4, 8 and 12 post-surgery. Results Despite similar initial thrombus size, the presence of ongoing blood flow (stenosis model) was associated with a 45.91% subsequent improvement in thrombus resolution at day 8, and 12.57% at day 12, as compared with stasis thrombosis (ligation model). Immunoblot and real-time PCR demonstrated a difference in MMP-2 and MMP-9 activity at day 8 between the two models (P=.03 and P=.006 respectively), as well as a difference in MT2-MMP gene expression at day 8 (P=.044) and day 12 (P=0.03) and MT1-MMP protein expression at day 4 (P=.021). Histological analyses revealed distinct areas of recanalization in the thrombi of the stenosis model compared to the ligation model, as well as the recruitment of inflammatory cells, especially macrophages, and a focal pattern of localized expression of MT1-MMP and MT3-MMP proteins surrounding the areas of recanalization in the stenosis model. Conclusions Recanalization and ongoing blood flow accelerate deep venous thrombus resolution in vivo, and are associated with distinct patterns of MT1- and MT3-MMP expression and macrophages localization in areas of intra-thrombus recanalization. PMID:26993683
Chabasse, Christine; Siefert, Suzanne A; Chaudry, Mohammed; Hoofnagle, Mark H; Lal, Brajesh K; Sarkar, Rajabrata
2015-01-01
We examined the role of thrombus recanalization and ongoing blood flow in the process of thrombus resolution by comparing two murine in vivo models of deep venous thrombosis. In CD1 mice, we performed surgical inferior vena cava ligation (stasis thrombosis), stenosis (thrombosis with recanalization), or sham procedure. We analyzed thrombus weight over time as a measure of thrombus resolution and quantified the messenger RNA and protein levels of membrane-type matrix metalloproteinases (MT-MMPs) as well as effectors of the plasmin complex at days 4, 8, and 12 after surgery. Despite similar initial thrombus size, the presence of ongoing blood flow (stenosis model) was associated with a 45.91% subsequent improvement in thrombus resolution at day 8 and 12.57% at day 12 compared with stasis thrombosis (ligation model). Immunoblot and real-time polymerase chain reaction analysis demonstrated a difference in MMP-2 and MMP-9 activity at day 8 between the two models (P = .03 and P = .006, respectively) as well as a difference in MT2-MMP gene expression at day 8 (P = .044) and day 12 (P = .03) and MT1-MMP protein expression at day 4 (P = .021). Histologic analyses revealed distinct areas of recanalization in the thrombi of the stenosis model compared with the ligation model as well as the recruitment of inflammatory cells, especially macrophages, and a focal pattern of localized expression of MT1-MMP and MT3-MMP proteins surrounding the areas of recanalization in the stenosis model. Recanalization and ongoing blood flow accelerate deep venous thrombus resolution in vivo and are associated with distinct patterns of MT1-MMP and MT3-MMP expression and macrophage localization in areas of intrathrombus recanalization. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Exercise thallium-201 perfusion scintigraphy in the assessment of coronary artery disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahmarian, J.J.; Verani, M.S.
1991-05-21
Exercise thallium-201 perfusion scintigraphy has been used extensively over the last decade for the detection and localization of coronary artery disease. Single-photon emission computed tomography (SPECT) is a refinement of presently available techniques, offering improved identification over planar imaging of individual vessel stenosis and quantification of the extent of abnormally perfused myocardium. In this review, the planar and SPECT techniques are discussed in light of the most recently published large patient series, and with regard to the many factors that affect the sensitivity and specificity of perfusion imaging in identifying coronary artery disease. The clinical implications of exercise perfusion scintigraphymore » and its future applications in cardiology practice are discussed.67 references.« less
Non-contrast-enhanced MRA of renal artery stenosis: validation against DSA in a porcine model.
Bley, T A; François, C J; Schiebler, M L; Wieben, O; Takei, N; Brittain, J H; Del Rio, A Munoz; Grist, T M; Reeder, S B
2016-02-01
To compare 3D-inversion-recovery balanced steady-state free precession (IR-bSSFP) non-contrast-enhanced magnetic resonance angiography (MRA) with 3D-contrast-enhanced MRA (CE-MRA) for assessment of renal artery stenosis (RAS) using digital subtraction angiography (DSA) as the reference standard. Bilateral RAS were surgically created in 12 swine. IR-bSSFP and CE-MRA were acquired at 1.5 T and compared to rotational DSA. Three experienced cardiovascular radiologists evaluated the IR-bSSFP and CE-MRA studies independently. Linear regression models were used to calibrate and assess the accuracy of IR-bSSFP and CE-MRA, separately, against DSA. The coefficient of determination and Cohen's kappa coefficient were also generated. Calibration of the three readers' RAS grading revealed R(2) values of 0.52, 0.37 and 0.59 for NCE-MRA and 0.48, 0.53 and 0.71 for CE-MRA. Inter-rater agreement demonstrated Cohen's kappa values ranging from 0.25 to 0.65. Distal renal artery branch vessels were visible to a significantly higher degree with NCE-MRA compared to CE-MRA (p < 0.001). Image quality was rated excellent for both sequences, although image noise was higher with CE-MRA (p < 0.05). In no cases did noise interfere with image interpretation. In a well-controlled animal model of surgically induced RAS, IR-bSSFP based NCE-MRA and CE-MRA accurately graded RAS with a tendency for stenosis overestimation, compared to DSA. • IR-bSSFP and CE-MRA are accurate methods for diagnosis of renal artery stenosis • IR-bSSFP and CE-MRA demonstrate excellent agreement with DSA • Both IR-bSSFP and CE-MRA have a tendency to overestimate renal artery stenosis.
Shepard, Lauren; Sommer, Kelsey; Izzo, Richard; Podgorsak, Alexander; Wilson, Michael; Said, Zaid; Rybicki, Frank J; Mitsouras, Dimitrios; Rudin, Stephen; Angel, Erin; Ionita, Ciprian N
2017-02-11
Accurate patient-specific phantoms for device testing or endovascular treatment planning can be 3D printed. We expand the applicability of this approach for cardiovascular disease, in particular, for CT-geometry derived benchtop measurements of Fractional Flow Reserve, the reference standard for determination of significant individual coronary artery atherosclerotic lesions. Coronary CT Angiography (CTA) images during a single heartbeat were acquired with a 320×0.5mm detector row scanner (Toshiba Aquilion ONE). These coronary CTA images were used to create 4 patient-specific cardiovascular models with various grades of stenosis: severe, <75% (n=1); moderate, 50-70% (n=1); and mild, <50% (n=2). DICOM volumetric images were segmented using a 3D workstation (Vitrea, Vital Images); the output was used to generate STL files (using AutoDesk Meshmixer), and further processed to create 3D printable geometries for flow experiments. Multi-material printed models (Stratasys Connex3) were connected to a programmable pulsatile pump, and the pressure was measured proximal and distal to the stenosis using pressure transducers. Compliance chambers were used before and after the model to modulate the pressure wave. A flow sensor was used to ensure flow rates within physiological reported values. 3D model based FFR measurements correlated well with stenosis severity. FFR measurements for each stenosis grade were: 0.8 severe, 0.7 moderate and 0.88 mild. 3D printed models of patient-specific coronary arteries allows for accurate benchtop diagnosis of FFR. This approach can be used as a future diagnostic tool or for testing CT image-based FFR methods.
Population-based study of esophageal and small intestinal atresia/stenosis.
Takahashi, Daijiro; Hiroma, Takehiko; Takamizawa, Shigeru; Nakamura, Tomohiko
2014-12-01
The aim of this study was to describe the prevalence of esophageal atresia/stenosis and small intestinal atresia/stenosis in Nagano, Japan, together with associated anomalies, prenatal diagnosis and survival. A population-based cohort study of the prevalence of esophageal atresia/stenosis and small intestinal atresia/stenosis was conducted in Nagano in January 1993-December 2011. The Mann-Whitney test, χ(2) test and Kruskal-Wallis test were used to compare variables. P < 0.05 was considered statistically significant. In total, 74 cases of esophageal atresia/stenosis and 87 cases of small intestinal atresia/stenosis (31 duodenal, 56 jejuno-ileal) were identified. Prevalences were 1.97 for esophageal atresia/stenosis and 2.23 for small intestinal atresia/stenosis (0.83 for duodenal atresia/stenosis and 1.49 for jejuno-ileal atresia/stenosis) per 10,000 births, respectively. The prevalence of esophageal atresia/stenosis increased significantly from 1993-2001 to 2002-2011 (relative risk [RR], 1.6), as did the prevalences of duodenal atresia/stenosis (RR, 2.2) and jejuno-ileal atresia/stenosis (RR, 3.1). Chromosomal anomalies, particularly trisomy 21, were seen significantly more often in association with duodenal atresia/stenosis (55%) than with esophageal atresia/stenosis (28%, P < 0.01) or jejuno-ileal atresia/stenosis (2%, P < 0.01). The proportion of patients associated with prenatally diagnosed chromosomal anomaly was higher compared to postnatal diagnosis (P < 0.01) in the esophageal atresia/stenosis group. The prevalence of esophageal and small intestinal atresia/stenosis increased significantly from 1993-2001 to 2002-2011. Prenatally diagnosed esophageal atresia/stenosis is associated with multiple anomalies, particularly chromosomal anomalies, compared to other small intestine atresia/stenosis. © 2014 Japan Pediatric Society.
Zhang, Yingyun; Zhang, Yufeng; Gao, Lian; Deng, Li; Hu, Xiao; Zhang, Kexin; Li, Haiyan
2017-11-01
This study assessed the variation in the frequency locations in the Doppler ultrasound spectra for the maximum blood flow velocities of in vessels with different degrees of bilaterally axisymmetric stenosis. This was done by comparing the relationship between the velocity distributions and corresponding Doppler power spectra. First, a geometric vessel model with axisymmetric stenosis was established. This made it possible to obtain the blood flow velocity distributions for different degrees of stenosis from the solutions of the Navier-Stokes equations. Then, the Doppler spectra were calculated for the entire segment of the vessel that was covered by the sound field. Finally, the maximum frequency locations for the spectra were determined based on the intersections of the maximum values chosen from the calculated blood flow velocity distributions and their corresponding spectra. The computational analysis showed that the maximum frequencies, which corresponded to the maximum blood flow velocities for different degrees of stenosis, were located at different positions along the spectral falling edges. The location for a normal (stenosis free) vessel was in the middle of the falling edge. For vessels with increasing degrees of stenosis, this location shifted approximately linearly downward along the falling edge. For 40% stenosis, the location reached a position at the falling edge of 0.32. Results obtained using the Field II simulation tool demonstrated the validity of the theoretical analysis and calculations, and may help to improve the maximum velocity estimation accuracy for Doppler blood flow spectra in stenosed vessels. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
... stenosis; LBP - stenosis Patient Instructions Spine surgery - discharge Images Sciatic nerve Spinal stenosis Spinal stenosis References Försth P, Ólafsson G, Carlsson T, et al. A randomized, controlled trial of fusion surgery for lumbar spinal stenosis. N Engl J ...
Tamoxifen decreases the myofibroblast count in the healing bile duct tissue of pigs
Siqueira, Orlando Hiroshi Kiono; Filho, Benedito Herani; de Paula, Rafael Erthal; Áscoli, Fábio Otero; da Nóbrega, Antonio Cláudio Lucas; Carvalho, Angela Cristina Gouvêa; Pires, Andréa Rodrigues Cordovil; Gaglionone, Nicolle Cavalcante; Cunha, Karin Soares Gonçalves; Granjeiro, José Mauro
2013-01-01
OBJECTIVE: The aim of this study was to evaluate the effect of oral tamoxifen treatment on the number of myofibroblasts present during the healing process after experimental bile duct injury. METHODS: The sample consisted of 16 pigs that were divided into two groups (the control and study groups). Incisions and suturing of the bile ducts were performed in the two groups. Tamoxifen (20 mg/day) was administered only to the study group. The animals were sacrificed after 30 days. Quantification of myofibroblasts in the biliary ducts was made through immunohistochemistry analysis using anti-alpha smooth muscle actin of the smooth muscle antibody. Immunohistochemical quantification was performed using a digital image system. RESULTS: In the animals treated with tamoxifen (20 mg/day), there was a significant reduction in immunostaining for alpha smooth muscle actin compared with the control group (0.1155 vs. 0.2021, p = 0.046). CONCLUSION: Tamoxifen reduced the expression of alpha smooth muscle actin in the healing tissue after bile duct injury, suggesting a decrease in myofibroblasts in the scarred area of the pig biliary tract. These data suggest that tamoxifen could be used in the prevention of biliary tract stenosis after bile duct surgeries. PMID:23420165
Nejad, A Abbas; Talebi, Z; Cheraghali, D; Shahbani-Zahiri, A; Norouzi, M
2018-02-01
In this study, the interaction of pulsatile blood flow with the viscoelastic walls of the axisymmetric artery is numerically investigated for different severities of stenosis. The geometry of artery is modeled by an axisymmetric cylindrical tube with a symmetric stenosis in a two-dimensional case. The effects of stenosis severity on the axial velocity profile, pressure distribution, streamlines, wall shear stress, and wall radial displacement for the viscoelastic artery are also compared to the elastics artery. Furthermore, the effects of atherosclerosis and polycythemia diseases on the hemodynamics and the mechanical behavior of arterial walls are investigated. The pulsatile flow of non-Newtonian blood is simulated inside the viscoelastic artery using the COMSOL Multiphysics software (version 5) and by employing the fluid-structure interaction (FSI) method and the arbitrary Lagrangian-Eulerian (ALE) method. Moreover, finite element method (FEM) is used to solve the governing equations on the unstructured grids. For modeling the non-Newtonian blood fluid and the viscoelastic arterial wall, the modified Casson model, and generalized Maxwell model are used, respectively. According to the results, with stenosis severity increasing from 25% to 75% at the time of maximum volumetric flow rate, the maximum value of axial velocity and its gradient increase 7.9 and 19.6 times, and the maximum wall shear stress of viscoelastic wall increases 24.2 times in the constriction zone. With the progression of the atherosclerosis disease (fivefold growth of arterial elastic modulus), the wall radial displacement of viscoelastic arterial walls decreases nearly 40%. In this study, axial velocity profile, pressure distribution, streamlines, wall radial displacement, and wall shear stress were examined for different percentages of stenosis (25%, 50%, and 75%). The atherosclerosis disease was investigated by the fivefold growth of viscoelastic arterial elastic modulus and polycythemia disease was examined by the 21-fold increase in the yield stress of the blood fluid. Furthermore, the comparison of results between the elastic and viscoelastic arterial walls shows that the wall radial displacement for viscoelastic artery is lower than that for the elastic artery as much as 21.7% for the severe stenosis of 75%. Copyright © 2017 Elsevier B.V. All rights reserved.
Atar, D; Ramanujam, P S; Saunamäki, K; Haunsø, S
1994-01-01
The aim of the study described here was to correlate coronary artery (CA) stenosis pressure gradients calculated by quantitative coronary arteriography (QCA) to invasively measured transstenotic pressure drops in patients with anginal symptoms and with known or suspected coronary artery disease. Furthermore, the known mathematical models are improved by introducing (1) pressure catheter-corrected minimal stenosis area, (2) modification of flow assumptions, and (3) stenosis exit angle. Included in the study were 45 patients with 61 stenoses. The visually estimated CA lesion severity in these non-complex stenoses was in the equivocal range of 40-70%. All measurements were performed after intracoronary administration of nifedipine and nitroglycerin. Stenosis dimensions were assessed from magnified cinefilms, using hand-held calipers. Highly significant overall correlation was found between measured and calculated pressure gradients with correction for the impact of the intracoronary catheter (P < 0.00001, r = 0.84). In particular, a substantial number of stenoses with haemodynamically-insignificant pressure gradients were identified by hydrodynamic calculations. In conclusion, the great majority of the coronary artery stenoses could be classified reliably by QCA as being haemodynamically insignificant or significant, respectively.
Novikov, Yu V; Shormanov, S V; Kulikov, S V
2012-01-01
Modeling of pulmonary trunk stenosis leads to an increase in hepatic vascular resistance because of veno-arterial and veno-venous reactions. During the compensation phase, bundles of intimal musculature and myoelastic sphincters appear in the arteries, while in the efferent veins hypertrophy of the muscle rolls is observed. The decompensation phase of stenosis is characterized by relaxation of hepatic vascular walls, reduction of the number of arteries with intimal muscles and sphincter structures, and atrophy of muscle rolls in hepatic veins. Sclerotic changes develop in the vascular bed. Failure of the compensatory reactions results in development of chronic hepatic venous plethora with typical morphological manifestations.
Investigating the effects of laryngotracheal stenosis on upper airway aerodynamics.
Cheng, Tracy; Carpenter, David; Cohen, Seth; Witsell, David; Frank-Ito, Dennis O
2018-04-01
Very little is known about the impact of laryngotracheal stenosis (LTS) on inspiratory airflow and resistance, especially in air hunger states. This study investigates the effect of LTS on airway resistance and volumetric flow across three different inspiratory pressures. Head-and-neck computed tomography scans of 11 subjects from 2010 to 2016 were collected. Three-dimensional reconstructions of the upper airway from the nostrils to carina, including the oral cavity, were created for one subject with a normal airway and for 10 patients with LTS. Airflow simulations were conducted using computational fluid dynamics modeling at three different inspiratory pressures (10, 25, 40 pascals [Pa]) for all subjects under two scenarios: 1) inspiration through nostrils only (MC), and 2) through both nostrils and mouth (MO). Volumetric flows in the normal subject at the three inspiratory pressures were considerably higher (MC: 11.8-26.1 L/min; MO: 17.2-36.9 L/min) compared to those in LTS (MC: 2.86-6.75 L/min; MO: 4.11-9.00 L/min). Airway resistances in the normal subject were 0.051 to 0.092 pascal seconds per milliliter (Pa.s)/mL (MC) and 0.035-0.065 Pa.s/mL (MO), which were approximately tenfold lower than those of subjects with LTS: 0.39 to 0.89 Pa.s/mL (MC) and 0.45 to 0.84 Pa.s/mL (MO). Furthermore, subjects with glottic stenosis had the greatest resistance, whereas subjects with subglottic stenosis had the greatest variability in resistance. Subjects with tracheal stenosis had the lowest resistance. This pilot study demonstrates that LTS increases resistance and decreases airflow. Mouth breathing significantly improved airflow and resistance but cannot completely compensate for the effects of stenosis. Furthermore, location of stenosis appears to modulate the effect of the stenosis on resistance differentially. NA. Laryngoscope, 128:E141-E149, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Balaras, Elias; Cha, K S; Griffith, Bartley P; Gammie, James S
2009-03-01
Aortic valve bypass surgery treats aortic valve stenosis with a valve-containing conduit that connects the left ventricular apex to the descending thoracic aorta. After aortic valve bypass, blood is ejected from the left ventricle via both the native stenotic aortic valve and the conduit. We performed computational modeling to determine the effects of aortic valve bypass on aortic and cerebral blood flow, as well as the effect of conduit size on relative blood flow through the conduit and the native valve. The interaction of blood flow with the vascular boundary was modeled using a hybrid Eurelian-Lagrangian formulation, where an unstructured Galerkin finite element method was coupled with an immersed boundary approach. Our model predicted native (stenotic) valve to conduit flow ratios of 45:55, 52:48, and 60:40 for conduits with diameters of 20, 16, and 10 mm, respectively. Mean gradients across the native aortic valve were calculated to be 12.5, 13.8, and 17.6 mm Hg, respectively. Post-aortic valve bypass cerebral blood flow was unchanged from preoperative aortic valve stenosis configurations and was constant across all conduit sizes. In all cases modeled, cerebral blood flow was completely supplied by blood ejected across the native aortic valve. An aortic valve bypass conduit as small as 10 mm results in excellent relief of left ventricular outflow tract obstruction in critical aortic valve stenosis. The presence of an aortic valve bypass conduit has no effect on cerebral blood flow. All blood flow to the brain occurs via antegrade flow across the native stenotic valve; this configuration may decrease the long-term risk of cerebral thromboembolism.
NASA Astrophysics Data System (ADS)
Shepard, Lauren; Sommer, Kelsey; Izzo, Richard; Podgorsak, Alexander; Wilson, Michael; Said, Zaid; Rybicki, Frank J.; Mitsouras, Dimitrios; Rudin, Stephen; Angel, Erin; Ionita, Ciprian N.
2017-03-01
Purpose: Accurate patient-specific phantoms for device testing or endovascular treatment planning can be 3D printed. We expand the applicability of this approach for cardiovascular disease, in particular, for CT-geometry derived benchtop measurements of Fractional Flow Reserve, the reference standard for determination of significant individual coronary artery atherosclerotic lesions. Materials and Methods: Coronary CT Angiography (CTA) images during a single heartbeat were acquired with a 320x0.5mm detector row scanner (Toshiba Aquilion ONE). These coronary CTA images were used to create 4 patientspecific cardiovascular models with various grades of stenosis: severe, <75% (n=1); moderate, 50-70% (n=1); and mild, <50% (n=2). DICOM volumetric images were segmented using a 3D workstation (Vitrea, Vital Images); the output was used to generate STL files (using AutoDesk Meshmixer), and further processed to create 3D printable geometries for flow experiments. Multi-material printed models (Stratasys Connex3) were connected to a programmable pulsatile pump, and the pressure was measured proximal and distal to the stenosis using pressure transducers. Compliance chambers were used before and after the model to modulate the pressure wave. A flow sensor was used to ensure flow rates within physiological reported values. Results: 3D model based FFR measurements correlated well with stenosis severity. FFR measurements for each stenosis grade were: 0.8 severe, 0.7 moderate and 0.88 mild. Conclusions: 3D printed models of patient-specific coronary arteries allows for accurate benchtop diagnosis of FFR. This approach can be used as a future diagnostic tool or for testing CT image-based FFR methods.
Ulrich, Nils H; Burgstaller, Jakob M; Pichierri, Giuseppe; Wertli, Maria M; Farshad, Mazda; Porchet, François; Steurer, Johann; Held, Ulrike
2017-09-15
Retrospective analysis of a prospective, multicenter cohort study. To estimate the added effect of surgical fusion as compared to decompression surgery alone in symptomatic lumbar spinal stenosis patients with spondylolisthesis. The optimal surgical management of lumbar spinal stenosis patients with spondylolisthesis remains controversial. Patients of the Lumbar Stenosis Outcome Study with confirmed DLSS and spondylolisthesis were enrolled in this study. The outcomes of this study were Spinal Stenosis Measure (SSM) symptoms (score range 1-5, best-worst) and function (1-4) over time, measured at baseline, 6, 12, 24, and 36 months follow-up. In order to quantify the effect of fusion surgery as compared to decompression alone and number of decompressed levels, we used mixed effects models and accounted for the repeated observations in main outcomes (SSM symptoms and SSM function) over time. In addition to individual patients' random effects, we also fitted random slopes for follow-up time points and compared these two approaches with Akaike's Information Criterion and the chi-square test. Confounders were adjusted with fixed effects for age, sex, body mass index, diabetes, Cumulative Illness Rating Scale musculoskeletal disorders, and duration of symptoms. One hundred thirty-one patients undergoing decompression surgery alone (n = 85) or decompression with fusion surgery (n = 46) were included in this study. In the multiple mixed effects model the adjusted effect of fusion compared with decompression alone surgery on SSM symptoms was 0.06 (95% confidence interval: -0.16-0.27) and -0.07 (95% confidence interval: -0.25-0.10) on SSM function, respectively. Among the patients with degenerative lumbar spinal stenosis and spondylolisthesis our study confirms that in the two groups, decompression alone and decompression with fusion, patients distinctively benefited from surgical treatment. When adjusted for confounders, fusion surgery was not associated with a more favorable outcome in both SSM scores as compared to decompression alone surgery. 3.
Far Forward Battlefield Telemedicine: Ultrasonic Guidance in Diagnosis and Emergency Therapeutics
2006-08-01
bicuspid aortic stenosis . J Am Soc Echocardiogr. 2005 Dec;18(12):1392-8. 44. Eto Y, Yamada H, Shin JH, Agler DA, Tsujino H, Qin JX, Saracino G, Greenberg...nitroprusside in aortic stenosis associated with severe heart failure: pressure- volume loop analysis using a numerical model. Am J Physiol Heart Circ...3D echocardiography, including exercise and intraoperative (epicardial) examinations, with quantitative validation in aneurysmal ventricles,3 aortic
NASA Astrophysics Data System (ADS)
Cheema, Taqi Ahmad; Park, Cheol Woo
2013-08-01
Stenosis is the drastic reduction of blood vessel diameter because of cholesterol accumulation in the vessel wall. In addition to the changes in blood flow characteristics, significant changes occur in the mechanical behavior of a stenotic blood vessel. We conducted a 3-D study of such behavior in micro-scale blood vessels by considering the fluid structure interaction between blood flow and vessel wall structure. The simulation consisted of one-way coupled analysis of blood flow and the resulting structural deformation without a moving mesh. A commercial code based on a finite element method with a hyperelastic material model (Neo-Hookean) of the wall was used to calculate wall deformation. Three different cases of stenosis severity and aspect ratios with and without muscles around the blood vessel were considered. The results showed that the wall deformation in a stenotic channel is directly related to stenosis severity and aspect ratio. The presence of muscles reduces the degree of deformation even in very severe stenosis.
Morelli, John N; Ai, Fei; Runge, Val M; Zhang, Wei; Li, Xiaoming; Schmitt, Peter; McNeal, Gary; Michaely, Henrick J; Schoenberg, Stefan O; Miller, Matthew; Gerdes, Clint M; Sincleair, Spencer T; Spratt, Heidi; Attenberger, Ulrike I
2012-09-01
To establish the minimum dose required for detection of renal artery stenosis using high temporal resolution, contrast enhanced MR angiography (MRA) in a porcine model. Surgically created renal artery stenoses were imaged with 3 Tesla MR and digital subtraction angiography (DSA) in 12 swine in this IACUC approved protocol. Gadobutrol was injected intravenously at doses of 0.5, 1, 2, and 4 mL for time-resolved MRA (1.5 × 1.5 mm(2) spatial resolution). Region of interest analysis was performed together with stenosis assessment and qualitative evaluation by two blinded readers. Mean signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were statistically significantly less with the 0.5-mL protocol (P < 0.001). There were no statistically significant differences among the other evaluated doses. Both readers found 10/12 cases with the 0.5-mL protocol to be of inadequate diagnostic quality (κ = 1.0). All other scans were found to be adequate for diagnosis. Accuracies in distinguishing between mild/insignificant (<50%) and higher grade stenoses (>50%) were comparable among the higher-dose protocols (sensitivities 73-93%, specificities 62-100%). Renal artery stenosis can be assessed with very low doses (~0.025 mmol/kg bodyweight) of a high concentration, high relaxivity gadolinium chelate formulation in a swine model, results which are promising with respect to limiting exposure to gadolinium based contrast agents. Copyright © 2012 Wiley Periodicals, Inc.
Efficacy of Surgical Airway Plasty for Benign Airway Stenosis.
Tsukioka, Takuma; Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji
2016-01-01
Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh-Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty.
Efficacy of Surgical Airway Plasty for Benign Airway Stenosis
Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji
2015-01-01
Background: Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Methods: Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Results: Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh–Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Conclusion: Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty. PMID:26567879
Delli Carri, Felice; Ruggiero, Maria Assunta; Cuculo, Andrea; Ruggiero, Antonio; Ziccardi, Luigi; De Gennaro, Luisa; Di Biase, Matteo
2014-01-01
Background Exact quantification of plaque extension during coronary angioplasty (PCI) usually falls on interventional cardiologist (IC). Quantitative coronary stenosis assessment (QCA) may be possibly committed to the radiology technician (RT), who usually supports cath-lab nurse and IC during PCI. We therefore sought to investigate the reliability of QCA performed by RT in comparison with IC. Methods Forty-four consecutive patients with acute coronary syndrome underwent PCI; target coronary vessel size beneath target coronary lesion (S) and target coronary lesion length (L) were assessed by the RT, junior IC (JIC), and senior IC (SIC) and then compared. SIC evaluation, which determined the final stent selection for coronary stenting, was considered as a reference benchmark. Results RT performance with QCA support in assessing target vessel size and target lesion length was not significantly different from SIC (r = 0.46, p < 0.01; r = 0.64, p < 0.001, respectively) as well as JIC (r = 0.79, r = 0.75, p < 0.001, respectively). JIC performance was significantly better than RT in assessing target vessel size (p < 0.05), while not significant when assessing target lesion length. Conclusions RT may reliably assess target lesion by using adequate QCA software in the cath-lab in case of PCI; RT performance does not differ from SIC. PMID:24672672
Murmur intensity in adult dogs with pulmonic and subaortic stenosis reflects disease severity.
Caivano, D; Dickson, D; Martin, M; Rishniw, M
2018-03-01
The aims of this study were to determine whether murmur intensity in adult dogs with pulmonic stenosis or subaortic stenosis reflects echocardiographic disease severity and to determine whether a six-level murmur grading scheme provides clinical advantages over a four-level scheme. In this retrospective multi-investigator study on adult dogs with pulmonic stenosis or subaortic stenosis, murmur intensity was compared to echocardiographically determined pressure gradient across the affected valve. Disease severity, based on pressure gradients, was assessed between sequential murmur grades to identify redundancy in classification. A simplified four-level murmur intensity classification scheme ('soft', 'moderate', 'loud', 'palpable') was evaluated. In total, 284 dogs (153 with pulmonic stenosis, 131 with subaortic stenosis) were included; 55 dogs had soft, 59 had moderate, 72 had loud and 98 had palpable murmurs. 95 dogs had mild stenosis, 46 had moderate stenosis, and 143 had severe stenosis. No dogs with soft murmurs of either pulmonic or subaortic stenosis had transvalvular pressure gradients greater than 50 mmHg. Dogs with loud or palpable murmurs mostly, but not always, had severe stenosis. Stenosis severity increased with increasing murmur intensity. The traditional six-level murmur grading scheme provided no additional clinical information than the four-level descriptive murmur grading scheme. A simplified descriptive four-level murmur grading scheme differentiated stenosis severity without loss of clinical information, compared to the traditional six-level scheme. Soft murmurs in dogs with pulmonic or subaortic stenosis are strongly indicative of mild lesions. Loud or palpable murmurs are strongly suggestive of severe stenosis. © 2017 British Small Animal Veterinary Association.
Molecular Regulation of Endothelial Cells by NF-1
2012-07-01
disease. Patients with NF1 disease make up a significant portion of all those patients presenting with renal artery stenosis and early-onset cerebral...affected individuals can be quite variable. Perhaps the most common is renal artery stenosis and hypertension. The renal artery is also a site of...aneurysms and aortic coarctation (Zochodne 1984). Recently a model was developed in the Epstein lab where NF1 was knocked out specifically in the smooth
Influence of Lumbar Lordosis on the Outcome of Decompression Surgery for Lumbar Canal Stenosis.
Chang, Han Soo
2018-01-01
Although sagittal spinal balance plays an important role in spinal deformity surgery, its role in decompression surgery for lumbar canal stenosis is not well understood. To investigate the hypothesis that sagittal spinal balance also plays a role in decompression surgery for lumbar canal stenosis, a prospective cohort study analyzing the correlation between preoperative lumbar lordosis and outcome was performed. A cohort of 85 consecutive patients who underwent decompression for lumbar canal stenosis during the period 2007-2011 was analyzed. Standing lumbar x-rays and 36-item short form health survey questionnaires were obtained before and up to 2 years after surgery. Correlations between lumbar lordosis and 2 parameters of the 36-item short form health survey (average physical score and bodily pain score) were statistically analyzed using linear mixed effects models. There was a significant correlation between preoperative lumbar lordosis and the 2 outcome parameters at postoperative, 6-month, 1-year, and 2-year time points. A 10° increase of lumbar lordosis was associated with a 5-point improvement in average physical scores. This correlation was not present in preoperative scores. This study showed that preoperative lumbar lordosis significantly influences the outcome of decompression surgery on lumbar canal stenosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Freehand three-dimensional ultrasound imaging of carotid artery using motion tracking technology.
Chung, Shao-Wen; Shih, Cho-Chiang; Huang, Chih-Chung
2017-02-01
Ultrasound imaging has been extensively used for determining the severity of carotid atherosclerotic stenosis. In particular, the morphological characterization of carotid plaques can be performed for risk stratification of patients. However, using 2D ultrasound imaging for detecting morphological changes in plaques has several limitations. Due to the scan was performed on a single longitudinal cross-section, the selected 2D image is difficult to represent the entire morphology and volume of plaque and vessel lumen. In addition, the precise positions of 2D ultrasound images highly depend on the radiologists' experience, it makes the serial long-term exams of anti-atherosclerotic therapies are difficult to relocate the same corresponding planes by using 2D B-mode images. This has led to the recent development of three-dimensional (3D) ultrasound imaging, which offers improved visualization and quantification of complex morphologies of carotid plaques. In the present study, a freehand 3D ultrasound imaging technique based on optical motion tracking technology is proposed. Unlike other optical tracking systems, the marker is a small rigid body that is attached to the ultrasound probe and is tracked by eight high-performance digital cameras. The probe positions in 3D space coordinates are then calibrated at spatial and temporal resolutions of 10μm and 0.01s, respectively. The image segmentation procedure involves Otsu's and the active contour model algorithms and accurately detects the contours of the carotid arteries. The proposed imaging technique was verified using normal artery and atherosclerotic stenosis phantoms. Human experiments involving freehand scanning of the carotid artery of a volunteer were also performed. The results indicated that compared with manual segmentation, the lowest percentage errors of the proposed segmentation procedure were 7.8% and 9.1% for the external and internal carotid arteries, respectively. Finally, the effect of handshaking was calibrated using the optical tracking system for reconstructing a 3D image. Copyright © 2016 Elsevier B.V. All rights reserved.
Yoo, Jung-Geun; Yi, Chin A; Lee, Kyung Soo; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung
2015-01-01
Objectives The shape of the flow-volume (F-V) curve is known to change to showing a prominent plateau as stenosis progresses in patients with tracheal stenosis. However, no study has evaluated changes in the F-V curve according to the degree of bronchial stenosis in patients with unilateral main bronchial stenosis. Methods We performed an analysis of F-V curves in 29 patients with unilateral bronchial stenosis with the aid of a graphic digitizer between January 2005 and December 2011. Results The primary diseases causing unilateral main bronchial stenosis were endobronchial tuberculosis (86%), followed by benign bronchial tumor (10%), and carcinoid (3%). All unilateral main bronchial stenoses were classified into one of five grades (I, ≤25%; II, 26%-50%; III, 51%-75%; IV, 76%-90%; V, >90% to near-complete obstruction without ipsilateral lung collapse). A monophasic F-V curve was observed in patients with grade I stenosis and biphasic curves were observed for grade II-IV stenosis. Both monophasic (81%) and biphasic shapes (18%) were observed in grade V stenosis. After standardization of the biphasic shape of the F-V curve, the breakpoints of the biphasic curve moved in the direction of high volume (x-axis) and low flow (y-axis) according to the progression of stenosis. Conclusion In unilateral bronchial stenosis, a biphasic F-V curve appeared when bronchial stenosis was >25% and disappeared when obstruction was near complete. In addition, the breakpoint moved in the direction of high volume and low flow with the progression of stenosis. PMID:26045916
Surgical treatment of anal stenosis
Brisinda, Giuseppe; Vanella, Serafino; Cadeddu, Federica; Marniga, Gaia; Mazzeo, Pasquale; Brandara, Francesco; Maria, Giorgio
2009-01-01
Anal stenosis is a rare but serious complication of anorectal surgery, most commonly seen after hemorrhoidectomy. Anal stenosis represents a technical challenge in terms of surgical management. A Medline search of studies relevant to the management of anal stenosis was undertaken. The etiology, pathophysiology and classification of anal stenosis were reviewed. An overview of surgical and non-surgical therapeutic options was developed. Ninety percent of anal stenosis is caused by overzealous hemorrhoidectomy. Treatment, both medical and surgical, should be modulated based on stenosis severity. Mild stenosis can be managed conservatively with stool softeners or fiber supplements. Sphincterotomy may be quite adequate for a patient with a mild degree of narrowing. For more severe stenosis, a formal anoplasty should be performed to treat the loss of anal canal tissue. Anal stenosis may be anatomic or functional. Anal stricture is most often a preventable complication. Many techniques have been used for the treatment of anal stenosis with variable healing rates. It is extremely difficult to interpret the results of the various anaplastic procedures described in the literature as prospective trials have not been performed. However, almost any approach will at least improve patient symptoms. PMID:19399922
Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu
2016-11-01
Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.
Liepsch, D W; Levesque, M; Nerem, R M; Moravec, S T
1988-01-01
Laser-Doppler-velocity measurements were carried out in an elastic 1:1 true-to-scale silicone rubber model of a dog aorta with stenosis. The model was constructed from a cast of a severely stenosed dog aorta (71% of its area). The stenosis in the dog aorta was prepared by wrapping a cotton band around the aorta. This band was tightened until the presence of a thrill or a bruit was felt distal to the band. Twelve weeks later the animal was sacrificed and a cast was prepared from the aorta. From this vascular cast, the cross-sectional area was calculated. Endothelial cell geometry and orientation was studied using computerized analysis to determine the cell area and shape index. An elastic silicone rubber model was prepared from the cast to measure the velocity profiles and to estimate the local wall shear stress. Velocity measurements were done at steady and pulsatile flow using a Newtonian aqueous-glycerol solution and a non-Newtonian blood-like fluid. From those velocity measurements the velocity gradients near the wall were determined and the shear stress calculated. The flow distal to the stenosis separates from the wall at physiological conditions. The endothelial cells are smaller and more elongated in the throat; distal to the stenosis they are larger and rounder. The shape index distribution along the stenosed aorta is correlated with the level of wall shear stress. It is shown that even low changes in the wall shear stress have an influence on the orientation of the endothelial cells.
Schneider, Michael; Ammendolia, Carlo; Murphy, Donald; Glick, Ronald; Piva, Sara; Hile, Elizabeth; Tudorascu, Dana; Morton, Sally C
2014-01-01
Lumbar spinal stenosis is the most common reason for spinal surgery in older adults. Previous studies have shown that surgery is effective for severe cases of stenosis, but many patients with mild to moderate symptoms are not surgical candidates. These patients and their providers are seeking effective non-surgical treatment methods to manage their symptoms; yet there is a paucity of comparative effectiveness research in this area. This knowledge gap has hindered the development of clinical practice guidelines for non-surgical treatment approaches for lumbar spinal stenosis. This study is a prospective randomized controlled clinical trial that will be conducted from November 2013 through October 2016. The sample will consist of 180 older adults (>60 years) who have both an anatomic diagnosis of stenosis confirmed by diagnostic imaging, and signs/symptoms consistent with a clinical diagnosis of lumbar spinal stenosis confirmed by clinical examination. Eligible subjects will be randomized into one of three pragmatic treatment groups: 1) usual medical care; 2) individualized manual therapy and rehabilitative exercise; or 3) community-based group exercise. All subjects will be treated for a 6-week course of care. The primary subjective outcome is the Swiss Spinal Stenosis Questionnaire, a self-reported measure of pain/function. The primary objective outcome is the Self-Paced Walking Test, a measure of walking capacity. The secondary objective outcome will be a measurement of physical activity during activities of daily living, using the SenseWear Armband, a portable device to be worn on the upper arm for one week. The primary analysis will use linear mixed models to compare the main effects of each treatment group on the changes in each outcome measure. Secondary analyses will include a responder analysis by group and an exploratory analysis of potential baseline predictors of treatment outcome. Our study should provide evidence that helps to inform patients and providers about the clinical benefits of three non-surgical approaches to the management of lumbar spinal stenosis symptoms. ClinicalTrials.gov identifier: NCT01943435.
2014-01-01
Background Lumbar spinal stenosis is the most common reason for spinal surgery in older adults. Previous studies have shown that surgery is effective for severe cases of stenosis, but many patients with mild to moderate symptoms are not surgical candidates. These patients and their providers are seeking effective non-surgical treatment methods to manage their symptoms; yet there is a paucity of comparative effectiveness research in this area. This knowledge gap has hindered the development of clinical practice guidelines for non-surgical treatment approaches for lumbar spinal stenosis. Methods/design This study is a prospective randomized controlled clinical trial that will be conducted from November 2013 through October 2016. The sample will consist of 180 older adults (>60 years) who have both an anatomic diagnosis of stenosis confirmed by diagnostic imaging, and signs/symptoms consistent with a clinical diagnosis of lumbar spinal stenosis confirmed by clinical examination. Eligible subjects will be randomized into one of three pragmatic treatment groups: 1) usual medical care; 2) individualized manual therapy and rehabilitative exercise; or 3) community-based group exercise. All subjects will be treated for a 6-week course of care. The primary subjective outcome is the Swiss Spinal Stenosis Questionnaire, a self-reported measure of pain/function. The primary objective outcome is the Self-Paced Walking Test, a measure of walking capacity. The secondary objective outcome will be a measurement of physical activity during activities of daily living, using the SenseWear Armband, a portable device to be worn on the upper arm for one week. The primary analysis will use linear mixed models to compare the main effects of each treatment group on the changes in each outcome measure. Secondary analyses will include a responder analysis by group and an exploratory analysis of potential baseline predictors of treatment outcome. Discussion Our study should provide evidence that helps to inform patients and providers about the clinical benefits of three non-surgical approaches to the management of lumbar spinal stenosis symptoms. Trial registration ClinicalTrials.gov identifier: NCT01943435 PMID:24872875
Fluid dynamics of aortic valve stenosis
NASA Astrophysics Data System (ADS)
Keshavarz-Motamed, Zahra; Maftoon, Nima
2009-11-01
Aortic valve stenosis, which causes considerable constriction of the flow passage, is one of the most frequent cardiovascular diseases and is the most common cause of the valvular replacements which take place for around 100,000 per year in North America. Furthermore, it is considered as the most frequent cardiac disease after arterial hypertension and coronary artery disease. The objective of this study is to develop an analytical model considering the coupling effect between fluid flow and elastic deformation with reasonable boundary conditions to describe the effect of AS on the left ventricle and the aorta. The pulsatile and Newtonian blood flow through aortic stenosis with vascular wall deformability is analyzed and its effects are discussed in terms of flow parameters such as velocity, resistance to flow, shear stress distribution and pressure loss. Meanwhile we developed analytical expressions to improve the comprehension of the transvalvular hemodynamics and the aortic stenosis hemodynamics which is of great interest because of one main reason. To medical scientists, an accurate knowledge of the mechanical properties of whole blood flow in the aorta can suggest a new diagnostic tool.
Behaviour of two typical stents towards a new stent evolution.
Simão, M; Ferreira, J M; Mora-Rodriguez, J; Fragata, J; Ramos, H M
2017-06-01
This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interaction are used to assess the haemodynamic impact of two types of coronary stents implantation: (1) type 1-based on a strut-link stent geometry and (2) type 2-a continuous helical stent. Using data from a recent clinical stenosis, flow disturbances and consequent shear stress alterations introduced by the stent treatment are investigated. A relationship between stenosis and the induced flow fields for the two types of stent designs is analysed as well as the correlation between haemodynamics and vessel wall biomechanical factors during the initiation and development of stenosis formation in the coronary artery. Both stents exhibit a good performance in reducing the obstruction artery. However, stent type 1 presents higher radial deformation than the type 2. This deformation can be seen as a limitation with a long-term clinical impact.
Cryoplasty for Canine Iliac Artery Stenosis and its Impact on Expression of TIMP-2 and MMP-2.
Wu, Zhengzhong; Zang, Shengbing; Liu, Wenwen; Jiang, Na; Yang, Weizhu
2015-01-01
This study was performed to observe the effects of cryoplasty on canine iliac artery stenosis and the expression of tissue inhibition of matrix metalloproteinase 2 (TIMP-2) and matrix metalloproteinase 2 (MMP-2). We produced a reliable canine model to mimic the atherosclerotic stenosis in the iliac artery by suturing the artery followed by vessel ligation to create an injury to intimal and medial walls. Sixteen mongrel dogs with iliac artery stenosis were randomized to conventional balloon angioplasty (n = 8) or cryoplasty (n = 8). Four weeks posttreatment, the cryoplasty group with less collagen fibers and smooth muscle demonstrated significantly larger luminal diameter of iliac artery compared to the balloon angioplasty group (P < .001). Expression of TIMP-2 significantly increased and expression of MMP-2 significantly reduced in iliac artery of the cryoplasty group compared to conventional balloon angioplasty. Our study suggests cryoplasty might increase the expression of TIMP-2 and decrease the expression of MMP-2, thereby inhibiting vascular hyperplasia and collagen fibers synthesis of the stenotic vessels. © The Author(s) 2015.
Computational Modeling of Aortic Valvular Stenosis to Asses the Range of Validity of Gorlin Equation
NASA Astrophysics Data System (ADS)
Okpara, Emanuel; Agarwal, Ramesh; Rifkin, Robert; Wendl, Mike
2003-11-01
It is well known from clinical observations that the underestimation errors occur with the use of Gorlin formula (1) for the calculation of valve area of the stenotic aortic valve in patients with low cardiac output, that is in low flow states. Since 1951, empirical modifications to Gorlin formula have been proposed in the literaure by many researchers. In this paper, we study the mild to severe aortic valve stenosis for low to high flow rates by employing a simplified model of aortic valve. The aortic valve stenosis is modeled by a circular orifice in a flat plate embedded in the cross-section of a rigid tube (aorta). Experimental results are available for this configuration for the validation of a CFD solver "FLUENT". The numerical data base generated for this model for various degrees of stenoses and flow rates is employed to asses the range of validity of Gorlin's equation. Modifications to Gorlin formula are suggested to make it valid for all flow rates to determine the valve area for clinical use. (1) R. Gorlin and S. Gorlin," Hydraulic Formula for Calculation of the Area of Stenotic Mitral Valve, Other Cardiac Valves and Central Circulatory Shunts," Am. Heart Journal, Vol. 41, 1951, pp. 1-29.
Nonstent Combination Interventional Therapy for Treatment of Benign Cicatricial Airway Stenosis
Qiu, Xiao-Jian; Zhang, Jie; Wang, Ting; Pei, Ying-Hua; Xu, Min
2015-01-01
Background: Benign cicatricial airway stenosis (BCAS) is a life-threatening disease. While there are numerous therapies, all have their defects, and stenosis can easily become recurrent. This study aimed to investigate the efficacy and complications of nonstent combination interventional therapy (NSCIT) when used for the treatment of BCAS of different causes and types. Methods: This study enrolled a cohort of patients with BCAS resulting from tuberculosis, intubation, tracheotomy, and other origins. The patients were assigned to three groups determined by their type of stenosis: Web-like stenosis, granulation stenosis, and complex stenosis, and all patients received NSCIT. The efficacy and complications of treatment in each group of patients were observed. The Chi-square test, one-factor analysis of variance (ANOVA), and the paired t-test were used to analyze different parameters. Results: The 10 patients with web-like stenosis and six patients with granulation stenosis exhibited durable remission rates of 100%. Among 41 patients with complex stenosis, 36 cases (88%) experienced remission and 29 cases (71%) experienced durable remission. When five patients with airway collapse were eliminated from the analysis, the overall remission rate was 97%. The average treatment durations for patients with web-like stenosis, granulation stenosis, and complex stenosis were 101, 21, and 110 days, respectively, and the average number of treatments was five, two, and five, respectively. Conclusions: NSCIT demonstrated good therapeutic efficacy and was associated with few complications. However, this approach was ineffective for treating patients with airway collapse or malacia. PMID:26265607
Nonstent Combination Interventional Therapy for Treatment of Benign Cicatricial Airway Stenosis.
Qiu, Xiao-Jian; Zhang, Jie; Wang, Ting; Pei, Ying-Hua; Xu, Min
2015-08-20
Benign cicatricial airway stenosis (BCAS) is a life-threatening disease. While there are numerous therapies, all have their defects, and stenosis can easily become recurrent. This study aimed to investigate the efficacy and complications of nonstent combination interventional therapy (NSCIT) when used for the treatment of BCAS of different causes and types. This study enrolled a cohort of patients with BCAS resulting from tuberculosis, intubation, tracheotomy, and other origins. The patients were assigned to three groups determined by their type of stenosis: Web-like stenosis, granulation stenosis, and complex stenosis, and all patients received NSCIT. The efficacy and complications of treatment in each group of patients were observed. The Chi-square test, one-factor analysis of variance (ANOVA), and the paired t -test were used to analyze different parameters. The 10 patients with web-like stenosis and six patients with granulation stenosis exhibited durable remission rates of 100%. Among 41 patients with complex stenosis, 36 cases (88%) experienced remission and 29 cases (71%) experienced durable remission. When five patients with airway collapse were eliminated from the analysis, the overall remission rate was 97%. The average treatment durations for patients with web-like stenosis, granulation stenosis, and complex stenosis were 101, 21, and 110 days, respectively, and the average number of treatments was five, two, and five, respectively. NSCIT demonstrated good therapeutic efficacy and was associated with few complications. However, this approach was ineffective for treating patients with airway collapse or malacia.
Lumbosacral stenosis in Labrador retriever military working dogs - an exomic exploratory study.
Mukherjee, Meenakshi; Jones, Jeryl C; Yao, Jianbo
2017-01-01
Canine lumbosacral stenosis is defined as narrowing of the caudal lumbar and/or sacral vertebral canal. A risk factor for neurologic problems in many large sized breeds, lumbosacral stenosis can also cause early retirement in Labrador retriever military working dogs. Though vital for conservative management of the condition, early detection is complicated by the ambiguous nature of clinical signs of lumbosacral stenosis in stoic and high-drive Labrador retriever military working dogs. Though clinical diagnoses of lumbosacral stenosis using CT imaging are standard, they are usually not performed unless dogs present with clinical symptoms. Understanding the underlying genomic mechanisms would be beneficial in developing early detection methods for lumbosacral stenosis, which could prevent premature retirement in working dogs. The exomes of 8 young Labrador retriever military working dogs (4 affected and 4 unaffected by lumbosacral stenosis, phenotypically selected by CT image analyses from 40 dogs with no reported clinical signs of the condition) were sequenced to identify and annotate exonic variants between dogs negative and positive for lumbosacral stenosis. Two-hundred and fifty-two variants were detected to be homozygous for the wild allele and either homozygous or heterozygous for the variant allele. Seventeen non-disruptive variants were detected that could affect protein effectiveness in 7 annotated (SCN1B, RGS9BP, ASXL3, TTR, LRRC16B, PTPRO, ZBBX) and 3 predicted genes (EEF1A1, DNAJA1, ZFX). No exonic variants were detected in any of the canine orthologues for human lumbar spinal stenosis candidate genes. TTR (transthyretin) gene could be a possible candidate for lumbosacral stenosis in Labrador retrievers based on previous human studies that have reported an association between human lumbar spinal stenosis and transthyretin protein amyloidosis. Other genes identified with exonic variants in this study but with no known published association with lumbosacral stenosis and/or lumbar spinal stenosis could also be candidate genes for future canine lumbosacral stenosis studies but their roles remain currently unknown. Human lumbar spinal stenosis candidate genes also cannot be ruled out as lumbosacral stenosis candidate genes. More definitive genetic investigations of this condition are needed before any genetic test for lumbosacral stenosis in Labrador retriever can be developed.
Waltenberger, Birgit; Liu, Rongxia; Atanasov, Atanas G; Schwaiger, Stefan; Heiss, Elke H; Dirsch, Verena M; Stuppner, Hermann
2015-11-13
Aberrant proliferation of vascular smooth muscle cells (VSMC) plays a major role in restenosis, the pathological renarrowing of the blood vessel lumen after surgical treatment of stenosis. Since available anti-proliferative pharmaceuticals produce unfavorable side effects, there is high demand for the identification of novel VSMC proliferation inhibitors. A natural product screening approach using a resazurin conversion assay enabled the identification of gentisin (1) from Gentiana lutea as a novel inhibitor of VSMC proliferation with an IC50 value of 7.84 µM. Aiming to identify further anti-proliferative compounds, 13 additional nonprenylated xanthones, isolated from different plant species, were also tested. While some compounds showed no or moderate activity at 30 µM, 1-hydroxy-2,3,4,5-tetramethoxyxanthone (4), swerchirin (6), and methylswertianin (7) showed IC50 values between 10.2 and 12.5 µM. The anti-proliferative effect of 1, 4, 6, and 7 was confirmed by the quantification of DNA synthesis (BrdU incorporation) in VSMC. Cell death quantification (determined by LDH release in the culture medium) revealed that the compounds are not cytotoxic in the investigated concentration range. In conclusion, nonprenylated xanthones are identified as novel, non-toxic VSMC proliferation inhibitors, which might contribute to the development of new therapeutic applications to combat restenosis.
Association Between Gout and Aortic Stenosis
Chang, Kevin; Yokose, Chio; Tenner, Craig; Oh, Cheongeun; Donnino, Robert; Choy-Shan, Alana; Pike, Virginia C.; Shah, Binita D.; Lorin, Jeffrey D.; Krasnokutsky, Svetlana; Sedlis, Steven P.; Pillinger, Michael H.
2017-01-01
Background An independent association between gout and coronary artery disease is well established. The relationship between gout and valvular heart disease, however, is unclear. The aim of this study was to assess the association between gout and aortic stenosis. Methods We performed a retrospective case-control study. Aortic stenosis cases were identified through a review of outpatient transthoracic echocardiography (TTE) reports. Age-matched controls were randomly selected from patients who had undergone TTE and did not have aortic stenosis. Charts were reviewed to identify diagnoses of gout and the earliest dates of gout and aortic stenosis diagnosis. Results Among 1085 patients who underwent TTE, 112 aortic stenosis cases were identified. Cases and non-aortic stenosis controls (n=224) were similar in age and cardiovascular comorbidities. A history of gout was present in 21.4% (n=24) of aortic stenosis subjects compared with 12.5% (n=28) of controls (unadjusted OR 1.90, 95% CI 1.05–3.48, p=0.038). Multivariate analysis retained significance only for gout (adjusted OR 2.08, 95% CI 1.00–4.32, p=0.049). Among subjects with aortic stenosis and gout, gout diagnosis preceded aortic stenosis diagnosis by 5.8 ± 1.6 years. The age at onset of aortic stenosis was similar among patients with and without gout (78.7 ± 1.8 vs. 75.8 ± 1.0 years old, p=0.16). Conclusions Aortic stenosis patients had a markedly higher prevalence of precedent gout than age-matched controls. Whether gout is a marker of, or a risk factor for the development of aortic stenosis remains uncertain. Studies investigating the potential role of gout in the pathophysiology of aortic stenosis are warranted and could have therapeutic implications. PMID:27720853
Association Between Gout and Aortic Stenosis.
Chang, Kevin; Yokose, Chio; Tenner, Craig; Oh, Cheongeun; Donnino, Robert; Choy-Shan, Alana; Pike, Virginia C; Shah, Binita D; Lorin, Jeffrey D; Krasnokutsky, Svetlana; Sedlis, Steven P; Pillinger, Michael H
2017-02-01
An independent association between gout and coronary artery disease is well established. The relationship between gout and valvular heart disease, however, is unclear. The aim of this study was to assess the association between gout and aortic stenosis. We performed a retrospective case-control study. Aortic stenosis cases were identified through a review of outpatient transthoracic echocardiography (TTE) reports. Age-matched controls were randomly selected from patients who had undergone TTE and did not have aortic stenosis. Charts were reviewed to identify diagnoses of gout and the earliest dates of gout and aortic stenosis diagnosis. Among 1085 patients who underwent TTE, 112 aortic stenosis cases were identified. Cases and nonaortic stenosis controls (n = 224) were similar in age and cardiovascular comorbidities. A history of gout was present in 21.4% (n = 24) of aortic stenosis subjects compared with 12.5% (n = 28) of controls (unadjusted odds ratio 1.90, 95% confidence interval 1.05-3.48, P = .038). Multivariate analysis retained significance only for gout (adjusted odds ratio 2.08, 95% confidence interval 1.00-4.32, P = .049). Among subjects with aortic stenosis and gout, gout diagnosis preceded aortic stenosis diagnosis by 5.8 ± 1.6 years. The age at onset of aortic stenosis was similar among patients with and without gout (78.7 ± 1.8 vs 75.8 ± 1.0 years old, P = .16). Aortic stenosis patients had a markedly higher prevalence of precedent gout than age-matched controls. Whether gout is a marker of, or a risk factor for, the development of aortic stenosis remains uncertain. Studies investigating the potential role of gout in the pathophysiology of aortic stenosis are warranted and could have therapeutic implications. Published by Elsevier Inc.
Fischer, Kady; Guensch, Dominik P; Shie, Nancy; Lebel, Julie; Friedrich, Matthias G
2016-01-01
Background Breathing maneuvers can elicit a similar vascular response as vasodilatory agents like adenosine; yet, their potential diagnostic utility in the presence of coronary artery stenosis is unknown. The objective of the study is to investigate if breathing maneuvers can non-invasively detect inducible ischemia in an experimental animal model when the myocardium is imaged with oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR). Methods and Findings In 11 anesthetised swine with experimentally induced significant stenosis (fractional flow reserve <0.75) of the left anterior descending coronary artery (LAD) and 9 control animals, OS-CMR at 3T was performed during two different breathing maneuvers, a long breath-hold; and a combined maneuver of 60s of hyperventilation followed by a long breath-hold. The resulting change of myocardial oxygenation was compared to the invasive measurements of coronary blood flow, blood gases, and oxygen extraction. In control animals, all breathing maneuvers could significantly alter coronary blood flow as hyperventilation decreased coronary blood flow by 34±23%. A long breath-hold alone led to an increase of 97±88%, while the increase was 346±327% (p<0.001), when the long breath-hold was performed after hyperventilation. In stenosis animals, the coronary blood flow response was attenuated after both hyperventilation and the following breath-hold. This was matched by the observed oxygenation response as breath-holds following hyperventilation consistently yielded a significant difference in the signal of the MRI images between the perfusion territory of the stenosis LAD and remote myocardium. There was no difference between the coronary territories during the other breathing maneuvers or in the control group at any point. Conclusion In an experimental animal model, the response to a combined breathing maneuver of hyperventilation with subsequent breath-holding is blunted in myocardium subject to significant coronary artery stenosis. This maneuver may allow for detecting severe coronary artery stenosis and have a significant clinical potential as a non-pharmacological method for diagnostic testing in patients with suspected coronary artery disease. PMID:27741282
Gao, Shan; van 't Klooster, Ronald; Kitslaar, Pieter H; Coolen, Bram F; van den Berg, Alexandra M; Smits, Loek P; Shahzad, Rahil; Shamonin, Denis P; de Koning, Patrick J H; Nederveen, Aart J; van der Geest, Rob J
2017-10-01
The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. The proposed method segments the lumen and outer wall surfaces including the bifurcation region by fitting a subdivision surface constructed hierarchical-tree model to the image data. In particular, a hybrid segmentation which combines deformable model fitting with boundary classification was applied to extract the lumen surface. The 3D model ensures the correct shape and topology of the carotid artery, while the boundary classification uses combined image information of 3D TOF-MRA and 3D BB-MRI to promote accurate delineation of the lumen boundaries. The proposed algorithm was validated on 25 subjects (48 arteries) including both healthy volunteers and atherosclerotic patients with 30% to 70% carotid stenosis. For both lumen and outer wall border detection, our result shows good agreement between manually and automatically determined contours, with contour-to-contour distance less than 1 pixel as well as Dice overlap greater than 0.87 at all different carotid artery sections. The presented 3D segmentation technique has demonstrated the capability of providing vessel wall delineation for 3D carotid MRI data with high accuracy and limited user interaction. This brings benefits to large-scale patient studies for assessing the effect of pharmacological treatment of atherosclerosis by reducing image analysis time and bias between human observers. © 2017 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Badfar, Homayoun; Motlagh, Saber Yekani; Sharifi, Abbas
2017-10-01
In this paper, biomagnetic blood flow in the stenosis vessel under the effect of the solenoid magnetic field is studied using the ferrohydrodynamics (FHD) model. The parabolic profile is considered at an inlet of the axisymmetric stenosis vessel. Blood is modeled as electrically non-conducting, Newtonian and homogeneous fluid. Finite volume and the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm are utilized to discretize governing equations. The investigation is studied at different magnetic numbers ( MnF=164, 328, 1640 and 3280) and the number of the coil loops (three, five and nine loops). Results indicate an increase in heat transfer, wall shear stress and energy loss (pressure drop) with an increment in the magnetic number (ratio of Kelvin force to dynamic pressure force), arising from the FHD, and the number of solenoid loops. Furthermore, the flow pattern is affected by the magnetic field, and the temperature of blood can be decreased up to 1.48 {}°C under the effect of the solenoid magnetic field with nine loops and reference magnetic field ( B0) of 2 tesla.
NASA Astrophysics Data System (ADS)
Poepping, Tamie L.; Rankin, Richard N.; Holdsworth, David W.
2001-05-01
A unique in-vitro system has been developed that incorporates both realistic phantoms and flow. The anthropomorphic carotid phantoms are fabricated in agar with stenosis severity of 30% or 70% (by NASCET standards) and one of two geometric configurations- concentric or eccentric. The phantoms are perfused with a flow waveform that simulates normal common carotid flow. Pulsed Doppler ultrasound data are acquired at a 1 mm grid spacing throughout the lumen of the carotid bifurcation. To obtain a half-lumen volume, symmetric about the mid plane, requires a 13 hour acquisition over 3238 interrogation sites, producing 5.6 Gbytes of data. The spectral analysis produces estimates of parameters such as the peak velocity, mean velocity, spectral-broadening index, and turbulence intensity. Color-encoded or grayscale-encoded maps of these spectral parameters show distinctly different flow patterns resulting from stenoses of equal severity but different eccentricity. The most noticeable differences are seen in the volumes of the recirculation zones and the paths of the high-velocity jets. Elevated levels of turbulence intensity are also seen distal to the stenosis in the 70%-stenosed models.
Mihai, Georgeta; Winner, Marshall W; Raman, Subha V; Rajagopalan, Sanjay; Simonetti, Orlando P; Chung, Yiu-Cho
2012-02-01
To evaluate the use of a T2-weighted SPACE sequence (T2w-SPACE) to assess carotid stenosis via several methods and compare its performance with contrast-enhanced magnetic resonance angiography (ceMRA). Fifteen patients with carotid atherosclerosis underwent dark blood (DB)-MRI using a 3D turbo spin echo with variable flip angles sequence (T2w-SPACE) and ceMRA. Images were coregistered and evaluated by two observers. Comparisons were made for luminal diameter, luminal area, degree of luminal stenosis (NASCET: North American Symptomatic Endarterectomy Trial; ECST: European Carotid Surgery Trial, and area stenosis), and vessel wall area. Degree of NASCET stenosis was clinically classified as mild (<50%), moderate (50%-69%), or severe (>69%). Excellent agreement was seen between ceMRA and T2w-SPACE and between observers for assessment of lumen diameter, lumen area, vessel wall area, and degree of NASCET stenosis (r > 0.80, P < 0.001). ECST stenosis was consistently higher than NASCET stenosis (48 ± 14% vs. 24 ± 22%, P < 0.001). Area stenosis (72 ± 2%) was significantly higher (P < 0.001) than both ESCT and NASCET stenosis. DB-MRI of carotid arteries using T2w-SPACE is clinically feasible. It provides accurate measurements of lumen size and degree of stenosis in comparison with ceMRA and offers a more reproducible measure of ECST stenosis than ceMRA. Copyright © 2011 Wiley Periodicals, Inc.
Clinical Guideline for Treatment of Symptomatic Thoracic Spinal Stenosis.
Chen, Zhong-qiang; Sun, Chui-guo
2015-08-01
Thoracic spinal stenosis is a relatively common disorder causing paraplegia in the population of China. Until nowadays, the clinical management of thoracic spinal stenosis is still demanding and challenging with lots of questions remaining to be answered. A clinical guideline for the treatment of symptomatic thoracic spinal stenosis has been created by reaching the consensus of Chinese specialists using the best available evidence as a tool to aid practitioners involved with the care of this disease. In this guideline, many fundamental questions about thoracic spinal stenosis which were controversial have been explained clearly, including the definition of thoracic spinal stenosis, the standard procedure for diagnosing symptomatic thoracic spinal stenosis, indications for surgery, and so on. According to the consensus on the definition of thoracic spinal stenosis, the soft herniation of thoracic discs has been excluded from the pathological factors causing thoracic spinal stenosis. The procedure for diagnosing thoracic spinal stenosis has been quite mature, while the principles for selecting operative procedures remain to be improved. This guideline will be updated on a timely schedule and adhering to its recommendations should not be mandatory because it does not have the force of law. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.
Genetics Home Reference: supravalvular aortic stenosis
... Twitter Home Health Conditions Supravalvular aortic stenosis Supravalvular aortic stenosis Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Supravalvular aortic stenosis (SVAS) is a heart defect that develops before ...
Sarifuddin; Chakravarty, S; Mandal, P K; Layek, G C
2008-01-01
An updated numerical simulation of unsteady generalized Newtonian blood flow through differently shaped distensible arterial stenoses is developed. A shear-thinning fluid modelling the deformation dependent viscosity of blood is considered for the characterization of generalized Newtonian behaviour of blood. The arterial model is treated as two-dimensional and axisymmetric with an outline of the stenosis obtained from a three-dimensional casting of a mildly stenosed artery. The full Navier-Stokes equations governing blood flow are written in the dimensionless form and the solution is accomplished by finite time-step advancement through their finite difference staggered grid representations. The marker and cell (MAC) method comprising the use of a set of marker particles moving with the fluid is used for the purpose. Results are obtained for three differently shaped stenoses - irregular, smooth and cosine curve representations. The present results do agree well with those of existing investigations in the steady state, but contrary to their conclusions the present findings demonstrate that the excess pressure drop across the cosine and the smooth stenoses is caused by neither their smoothness nor their higher degree of symmetry relative to the irregular stenosis, but is rather an effect of area cover with respect to the irregular stenosis. This effect clearly prevails throughout the entire physiological range of Reynolds numbers. Further the in-depth study in flow patterns reveals the development of flow separation zones in the diverging part of the stenosis towards the arterial wall, and they are influenced by non-Newtonian blood rheology, distensibility of the wall and flow unsteadiness in order to validate the applicability of the present model.
Nakai, Katsuhiko; Takenobu, Yoshifumi; Takimizu, Hideyuki; Akimaru, Shinji; Ito, Hidenori; Maegawa, Hitoshi; Marsala, Martin; Katsube, Nobuo
2003-10-01
An orally active prostaglandin E1 analogue, OP-1206 alpha-CD improves walking dysfunction in the rat spinal stenosis model. Loxoprofen-Na, a non-steroidal anti-inflammatory drug, is used to relieve chronic pain in patients with lumbar spinal canal stenosis. To determine whether the OP-1206 alpha-CD in combination with loxoprofen-Na could induce a greater therapeutical effect on walking dysfunction and spinal cord blood flow (SCBF) than OP-1206 alpha-CD treatment alone after chronic spinal stenosis in the rat. Spinal stenosis was induced by placing two pieces of silicon rubber strips in the lumbar (L4 and L6) epidural space of rats. After surgery, walking function was measured using a treadmill apparatus and SCBF was measured using a laser-Doppler flow meter. Drugs were administered orally twice a day for 11 days from the day 3 post-surgery. OP-1206 alpha-CD elicited a significant improvement of walking dysfunction on days 7 and 14 post-surgery and significantly increased spinal cord blood flow on day 15, whereas walking dysfunction and SCBF of rats treated with loxoprofen-Na alone remained unchanged. Combined treatment of OP-1206 alpha-CD with loxoprofen-Na did not provide additive therapeutical effect. These results suggest that a significant improvement seen after OP-1206 alpha-CD treatment is primarily mediated by improvement of the local spinal cord blood flow. This effect is not ameliorated or potentiated by a combined treatment with loxoprofen-Na.
Accuracy of Carotid Duplex Criteria in Diagnosis of Significant Carotid Stenosis in Asian Patients.
Dharmasaroja, Pornpatr A; Uransilp, Nattaphol; Watcharakorn, Arvemas; Piyabhan, Pritsana
2018-03-01
Extracranial carotid stenosis can be diagnosed by velocity criteria of carotid duplex. Whether they are accurately applied to define severity of internal carotid artery (ICA) stenosis in Asian patients needs to be proved. The purpose of this study was to evaluate the accuracy of 2 carotid duplex velocity criteria in defining significant carotid stenosis. Carotid duplex studies and magnetic resonance angiography were reviewed. Criteria 1 was recommended by the Society of Radiologists in Ultrasound; moderate stenosis (50%-69%): peak systolic velocity (PSV) 125-230 cm/s, diastolic velocity (DV) 40-100 cm/s; severe stenosis (>70%): PSV greater than 230 cm/s, DV greater than 100 cm/s. Criteria 2 used PSV greater than 140 cm/s, DV less than 110 cm/s to define moderate stenosis (50%-75%) and PSV greater than 140 cm/s, DV greater than 110 cm/s for severe stenosis (76%-95%). A total of 854 ICA segments were reviewed. There was moderate stenosis in 72 ICAs, severe stenosis in 50 ICAs, and occlusion in 78 ICAs. Criteria 2 had slightly lower sensitivity, whereas higher specificity and accuracy than criteria 1 were observed in detecting moderate stenosis (criteria 1: sensitivity 95%, specificity 83%, accuracy 84%; criteria 2: sensitivity 92%, specificity 92%, and accuracy 92%). However, in detection of severe ICA stenosis, no significant difference in sensitivity, specificity, and accuracy was found (criteria 1: sensitivity 82%, specificity 99.57%, accuracy 98%; criteria 2: sensitivity 86%, specificity 99.68%, and accuracy 99%). In the subgroup of moderate stenosis, the criteria using ICA PSV greater than 140 cm/s had higher specificity and accuracy than the criteria using ICA PSV 125-230 cm/s. However, there was no significant difference in detection of severe stenosis or occlusion of ICA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Long-term outcome of vertebral artery origin stenosis in patients with acute ischemic stroke
2013-01-01
Background Vertebral artery origin (VAO) stenosis is occasionally observed in patients who have acute ischemic stroke. We investigated the long-term outcomes and clinical significance of VAO stenosis in patients with acute ischemic stroke. Methods We performed a prospective observational study using a single stroke center registry to investigate the risk of recurrent stroke and vascular outcomes in patients with acute ischemic stroke and VAO stenosis. To relate the clinical significance of VAO stenosis to the vascular territory of the index stroke, patients were classified into an asymptomatic VAO stenosis group and a symptomatic VAO stenosis group. Results Of the 774 patients who had acute ischemic stroke, 149 (19.3%) of them had more than 50% stenosis of the VAO. During 309 patient-years of follow-up (mean, 2.3 years), there were 7 ischemic strokes, 6 hemorrhagic strokes, and 2 unknown strokes. The annual event rates were 0.97% for posterior circulation ischemic stroke, 4.86% for all stroke, and 6.80% for the composite cardiovascular outcome. The annual event rate for ischemic stroke in the posterior circulation was significantly higher in patients who had symptomatic VAO stenosis than in patients who had asymptomatic stenosis (1.88% vs. 0%, p = 0.046). In a multivariate analysis, the hazard ratio, per one point increase of the Essen Stroke Risk Score (ESRS) for the composite cardiovascular outcome, was 1.46 (95% CI, 1.02-2.08, p = 0.036). Conclusions Long-term outcomes of more than 50% stenosis of the VAO in patients with acute ischemic stroke were generally favorable. Additionally, ESRS was a predictor for the composite cardiovascular outcome. Asymptomatic VAO stenosis may not be a specific risk factor for recurrent ischemic stroke in the posterior circulation. However, VAO stenosis may require more clinical attention as a potential source of recurrent stroke when VAO stenosis is observed in patients who have concurrent ischemic stroke in the posterior circulation. PMID:24215371
Early rectal stenosis following stapled rectal mucosectomy for hemorrhoids
Petersen, Sven; Hellmich, Gunter; Schumann, Dietrich; Schuster, Anja; Ludwig, Klaus
2004-01-01
Background Within the last years, stapled rectal mucosectomy (SRM) has become a widely accepted procedure for second and third degree hemorrhoids. One of the delayed complications is a stenosis of the lower rectum. In order to evaluate the specific problem of rectal stenosis following SRM we reviewed our data with special respect to potential predictive factors or stenotic events. Methods A retrospective analysis of 419 consecutive patients, which underwent SRM from December 1998 to August 2003 was performed. Only patients with at least one follow-up check were evaluated, thus the analysis includes 289 patients with a mean follow-up of 281 days (±18 days). For statistic analysis the groups with and without stenosis were evaluated using the Chi-Square Test, using the Kaplan-Meier statistic the actuarial incidence for rectal stenosis was plotted. Results Rectal stenosis was observed in 9 patients (3.1%), eight of these stenoses were detected within the first 100 days after surgery; the median time to stenosis was 95 days. Only one patient had a rectal stenosis after more than one year. 8 of the 9 patients had no obstructive symptoms, however the remaining patients complained of obstructive defecation and underwent surgery for transanal strictureplasty with electrocautery. A statistical analysis revealed that patients with stenosis had significantly more often prior treatment for hemorrhoids (p < 0.01). According to the SRM only severe postoperative pain was significantly associated with stenoses (p < 0.01). Other factors, such as gender (p = 0.11), surgical technique (p = 0.25), revision (p = 0.79) or histological evidence of squamous skin (p = 0.69) showed no significance. Conclusion Rectal stenosis is an uncommon event after SRM. Early stenosis will occur within the first three months after surgery. The majority of the stenoses are without clinical relevance. Only one of nine patients had to undergo surgery for a relevant stenosis. The predictive factor for stenosis in the patient-characteristics is previous interventions for hemorrhoids, severe postoperative pain might also predict rectal stenosis. PMID:15153248
Kitagami, Masayuki; Yasuda, Ryuta; Toma, Naoki; Shiba, Masato; Nampei, Mai; Yamamoto, Yoko; Nakatsuka, Yoshinari; Sakaida, Hiroshi; Suzuki, Hidenori
2017-08-01
Dyslipidemia is a well-known risk factor for carotid stenosis progression, but triglycerides have attracted little attention. The aim of this study was to assess if serum triglycerides affect progression of carotid stenosis in patients with well-controlled low-density lipoprotein cholesterol (LDL-C) levels. This is a retrospective study in a single hospital consisting of 71 Japanese patients with internal carotid artery stenosis greater than or equal to 50% and normal serum LDL-C levels who underwent angiographic examination with or without the resultant carotid artery stenting or endarterectomy from 2007 to 2011, and were subsequently followed up for 4 years. Clinical factors including fasting serum triglyceride values were compared between the progression (≥10% increase in degree of carotid stenosis on ultrasonography) and the nonprogression groups. During 4 years, 15 patients (21.1%) had carotid stenosis progression on either side. Cox regression analysis demonstrated that symptomatic cases (hazard ratio [HR], 4.327; P = .019), coexisting intracranial arteriosclerotic stenosis (HR, 5.341; P = .005), and hypertriglyceridemia (HR, 6.228; P = .011) were associated with subsequent progression of carotid stenosis. Kaplan-Meier plots demonstrated that the progression-free survival rate was significantly higher in patients without hypertriglyceridemia and intracranial arteriosclerotic stenosis at baseline. Among patients with moderate to severe carotid stenosis and well-controlled LDL-C, hypertriglyceridemia was an important risk factor for progression of carotid stenosis irrespective of surgical treatments. It would be worthwhile to test if triglyceride-lowering medications suppress carotid stenosis progression. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Johnson, Philippa; De Risio, Luisa; Sparkes, Andrew; McConnell, Fraser; Holloway, Andrew
2012-01-01
The clinical, morphologic, and morphometric features of cranial thoracic spinal stenosis were investigated in large and giant breed dogs. Seventy-nine magnetic resonance imaging studies of the cranial thoracic spine were assessed. Twenty-six were retrieved retrospectively and 53 were acquired prospectively using the same inclusion criteria. Images were evaluated using a modified compression scale as: no osseous stenosis (grade 0), osseous stenosis without spinal cord compression (grade 1), and osseous stenosis with spinal cord compression (grade 2). Morphometric analysis was performed and compared to the subjective grading system. Grades 1 and 2 cranial thoracic spinal stenosis were identified on 24 imaging studies in 23 dogs. Sixteen of 23 dogs had a conformation typified by Molosser breeds and 21/23 were male. The most common sites of stenosis were T2-3 and T3-4. The articular process joints were enlarged with abnormal oblique orientation. Stenosis was dorsolateral, lateralized, or dorsoventral. Concurrent osseous cervical spondylomyelopathy was recognized in six dogs and other neurologic disease in five dogs. Cranial thoracic spinal stenosis was the only finding in 12 dogs. In 9 of these 12 dogs (all grade 2) neurolocalization was to the T3-L3 spinal segment. The median age of these dogs was 9.5 months. In the remaining three dogs neurologic signs were not present. Stenosis ratios were of limited benefit in detecting stenotic sites. Grade 2 cranial thoracic spinal stenosis causing direct spinal cord compression may lead to neurologic signs, however milder stenosis (grade 1) is likely to be subclinical or incidental. © 2012 Veterinary Radiology & Ultrasound.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Paul D.; Foote, Robert L.; McLaughlin, Mark P.
2005-12-01
Purpose: To determine carotid artery stenosis incidence after radiotherapy for head-and-neck neoplasms. Methods and Materials: This historical prospective cohort study comprised 44 head-and-neck cancer survivors who received unilateral neck radiotherapy between 1974 and 1999. They underwent bilateral carotid duplex ultrasonography to detect carotid artery stenosis. Results: The incidence of significant carotid stenosis (8 of 44 [18%]) in the irradiated neck was higher than that in the contralateral unirradiated neck (3 of 44 [7%]), although this difference was not statistically significant (p = 0.13). The rate of significant carotid stenosis events increased as the time after radiotherapy increased. The risk ofmore » ipsilateral carotid artery stenosis was higher in patients who had undergone a neck dissection vs. those who had not. Patients with significant ipsilateral stenosis also tended to be older than those without significant stenosis. No other patient or treatment variables correlated with risk of carotid artery stenosis. Conclusions: For long-term survivors after neck dissection and irradiation, especially those who are symptomatic, ultrasonographic carotid artery screening should be considered.« less
Kolos, Igor; Loukianov, Mikhail; Dupik, Nikolay; Boytsov, Sergey; Deev, Alexandr
2015-02-01
Carotid endarterectomy and medical therapy (aspirin) were shown superior to medical therapy alone for asymptomatic (≥ 60%) carotid stenosis. The role of modern medical therapy (statins, antihypertensive treatment, and aspirin) in the treatment of such patients is undefined. Establishing the safety, efficacy, and durability of optimal medical therapy and lifestyle modification requires rigorous comparison with carotid endarterectomy in asymptomatic patients. The objective is to compare the efficacy of carotid endarterectomy + optimal medical therapy versus optimal medical therapy alone in patients with asymptomatic (70-79%) extracranial carotid stenosis. The Aggressive Medical Treatment Evaluation for Asymptomatic Carotid Artery Stenosis study is a prospective, randomized, parallel, two-arm, multicenter trial. Primary end-points will be analyzed using standard time-to-event statistical modeling with adjustment for major baseline covariates. The primary analysis is on an intent-to-treat basis. The primary outcome is nonfatal stroke, nonfatal myocardial infarction, and death during follow-up of up to five-years, and the secondary outcome includes death from any cause and stroke. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.
NASA Astrophysics Data System (ADS)
Potter, Lucas; Arikatla, Sreekanth; Bray, Aaron; Webb, Jeff; Enquobahrie, Andinet
2017-03-01
Stenosis of the upper airway affects approximately 1 in 200,000 adults per year1 , and occurs in neonates as well2 . Its treatment is often dictated by institutional factors and clinicians' experience or preferences 3 . Objective and quantitative methods of evaluating treatment options hold the potential to improve care in stenosis patients. Virtual surgical planning software tools are critically important for this. The Virtual Pediatric Airway Workbench (VPAW) is a software platform designed and evaluated for upper airway stenosis treatment planning. It incorporates CFD simulation and geometric authoring with objective metrics from both that help in informed evaluation and planning. However, this planner currently lacks physiological information which could impact the surgical planning outcomes. In this work, we integrated a lumped parameter, model based human physiological engine called BioGears with VPAW. We demonstrated the use of physiology informed virtual surgical planning platform for patient-specific stenosis treatment planning. The preliminary results show that incorporating patient-specific physiology in the pretreatment plan would play important role in patient-specific surgical trainers and planners in airway surgery and other types of surgery that are significantly impacted by physiological conditions during surgery.
Sun, Xuan; Tong, Xu; Lo, Wai Ting; Mo, Dapeng; Gao, Feng; Ma, Ning; Wang, Bo; Miao, Zhongrong
2017-03-01
We aimed to explore the risk factors of subacute thrombosis (SAT) after intracranial stenting for patients with symptomatic intracranial arterial stenosis. From January to December 2013, all symptomatic intracranial arterial stenosis patients who underwent intracranial stenting in Beijing Tiantan Hospital were prospectively registered into this study. Baseline clinical features and operative data were compared in patients who developed SAT with those who did not. Binary logistic regression model was used to determine the risk factors associated with SAT. Of the 221 patients enrolled, 9 (4.1%) cases had SAT 2 to 8 days after stenting. Binary logistic analysis showed that SAT was related with tandem stenting (odds ratio [OR], 11.278; 95% confidence interval [CI], 2.422-52.519) and antiplatelet resistance (aspirin resistance: OR, 6.267; 95% CI, 1.574-24.952; clopidogrel resistance: OR, 15.526; 95% CI, 3.105-77.626; aspirin and clopidogrel resistance: OR, 12.246; 95% CI, 2.932-51.147; and aspirin or clopidogrel resistance: OR, 11.340; 95% CI, 2.282-56.344). Tandem stenting and antiplatelet resistance might contribute to the development of SAT after intracranial stenting in patients with symptomatic intracranial arterial stenosis. © 2017 American Heart Association, Inc.
Sun, Anqiang; Tian, Xiaopeng; Zhang, Nan; Xu, Zaipin; Deng, Xiaoyan; Liu, Ming; Liu, Xiao
2015-01-01
Renal artery stenosis (RAS) and renal complications emerge in some patients after endovascular aneurysm repair (EVAR) to treat abdominal aorta aneurysm (AAA). The mechanisms for the causes of these problems are not clear. We hypothesized that for EVAR patients, lower limb exercise could negatively influence the physiology of the renal artery and the renal function, by decreasing the blood flow velocity and changing the hemodynamics in the renal arteries. To evaluate this hypothesis, pre- and post-operative models of the abdominal aorta were reconstructed based on CT images. The hemodynamic environment was numerically simulated under rest and lower limb exercise conditions. The results revealed that in the renal arteries, lower limb exercise decreased the wall shear stress (WSS), increased the oscillatory shear index (OSI) and increased the relative residence time (RRT). EVAR further enhanced these effects. Because these parameters are related to artery stenosis and atherosclerosis, this preliminary study concluded that lower limb exercise may increase the potential risk of inducing renal artery stenosis and renal complications for AAA patients. This finding could help elucidate the mechanism of renal artery stenosis and renal complications after EVAR and warn us to reconsider the management and nursing care of AAA patients.
Sahlein, Daniel H; Mora, Paloma; Becske, Tibor; Huang, Paul; Jafar, Jafar J; Connolly, E Sander; Nelson, Peter K
2014-07-01
Although there is generally thought to be a 2% to 4% per annum rupture risk for brain arteriovenous malformations (bAVMs), there is no way to estimate risk for an individual patient. In this retrospective study, patients were eligible who had nidiform bAVMs and underwent detailed pretreatment diagnostic cerebral angiography at our medical center from 1996 to 2006. All patients had superselective microcatheter angiography, and films were reviewed for the purpose of this project. Patient demographics, clinical presentation, and angioarchitectural characteristics were analyzed. A univariate analysis was performed, and angioarchitectural features with potential physiological significance that showed at least a trend toward significance were added to a multivariate logistic regression model. One hundred twenty-two bAVMs met criteria for study entry. bAVMs with single venous drainage anatomy were more likely to present with hemorrhage. In addition, patients with multiple draining veins and a venous stenosis reverted to a risk similar to those with 1 draining vein, whereas those with multiple draining veins and without stenosis had diminished association with hemorrhage presentation. Those bAVMs with associated aneurysms were more likely to present with hemorrhage. These findings were robust in both univariate and multivariate models. The results of this article lead to the first physiological, internally consistent model of individual bAVM hemorrhage risk, where 1 draining vein, venous stenosis, and associated aneurysms increase risk. © 2014 American Heart Association, Inc.
Treibel, Thomas A; Bandula, Steve; Fontana, Marianna; White, Steven K; Gilbertson, Janet A; Herrey, Anna S; Gillmore, Julian D; Punwani, Shonit; Hawkins, Philip N; Taylor, Stuart A; Moon, James C
2015-01-01
Cardiac involvement determines outcome in patients with systemic amyloidosis. There is major unmet need for quantification of cardiac amyloid burden, which is currently only met in part through semi-quantitative bone scintigraphy or Cardiovascular Magnetic Resonance (CMR), which measures ECVCMR. Other accessible tests are needed. To develop cardiac computed tomography to diagnose and quantify cardiac amyloidosis by measuring the myocardial Extracellular Volume, ECVCT. Twenty-six patients (21 male, 64 ± 14 years) with a biopsy-proven systemic amyloidosis (ATTR n = 18; AL n = 8) were compared with twenty-seven patients (19 male, 68 ± 8 years) with severe aortic stenosis (AS). All patients had undergone echocardiography, bone scintigraphy, NT-pro-BNP measurement and EQ-CMR. Dynamic Equilibrium CT (DynEQ-CT) was performed using a prospectively gated cardiac scan prior to and after (5 and 15 minutes) a standard Iodixanol (1 ml/kg) bolus to measure ECVCT. ECVCT was compared to the reference ECVCMR and conventional amyloid measures: bone scintigraphy and clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area). ECVCT and ECVCMR results were well correlated (r(2) = 0.85 vs r(2) = 0.74 for 5 and 15 minutes post bolus respectively). ECVCT was higher in amyloidosis than AS (0.54 ± 0.11 vs 0.28 ± 0.04, p<0.001) with no overlap. ECVCT tracked clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area), and bone scintigraphy amyloid burden (p<0.001). Dynamic Equilibrium CT, a 5 minute contrast-enhanced gated cardiac CT, has potential for non-invasive diagnosis and quantification of cardiac amyloidosis. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Balloon dilation of congenital supravalvular pulmonic stenosis in a dog.
Treseder, Julia R; Jung, SeungWoo
2017-03-30
Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented.
Wang, Ting; Zhang, Jie; Qiu, Xiao-Jian; Wang, Juan; Pei, Ying-Hua; Wang, Yu-Ling
2018-01-01
Background: Scarring airway stenosis is commonly seen in China as compared to other developed countries, due to the high prevalence of tuberculosis. Nowadays, interventional bronchoscopy treatment has been widely used to treat this disease in China. This study demonstrated the characteristics of scarring airway stenosis in Chinese adults and retrospectively evaluated the efficacy of interventional bronchoscopy treatment of this disease. Methods: Patients with scarring airway stenosis from 18 tertiary hospitals were enrolled between January 2013 and June 2016. The causes, site, and length of scarring airway stenosis were analyzed, and the efficacy of the interventional bronchoscopy treatment was evaluated. Results: The final study cohort consisted of 392 patients. Endotracheobronchial tuberculosis (EBTB) was the most common cause of scarring airway stenosis (305/392, 77.8%) in Chinese adults with a high rate of incidence in young women. The left main bronchus was most susceptible to EBTB, and most posttuberculosis airway scarring stenosis length was 1.1–2.0 cm. The average clinical success rate of interventional bronchoscopy treatment for scarring airway stenosis in Chinese patients is 60.5%. The stent was inserted in 8.7% scarring airway stenosis in China. Conclusions: Scarring airway stenosis exhibits specific characteristics in Chinese patients. Interventional bronchoscopy is a useful and safe treatment method for the disease. PMID:29363641
Investigation of spiral blood flow in a model of arterial stenosis.
Paul, Manosh C; Larman, Arkaitz
2009-11-01
The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360-1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard k-omega model is employed for simulation of the blood flow for the Reynolds number of 500 and 1000. We find that for Re=500 the spiral component of the blood flow increases both the total pressure and velocity of the blood, and some significant differences are found between the wall shear stresses of the spiral and non-spiral induced flow downstream of the stenosis. The turbulent kinetic energy is reduced by the spiral flow as it induces the rotational stabilities in the forward flow. For Re=1000 the tangential component of the blood velocity is most influenced by the spiral speed, but the effect of the spiral flow on the centreline turbulent kinetic energy and shear stress is mild. The results of the effects of the spiral flow are discussed in the paper along with the relevant pathological issues.
Grunau, Gilat L; Ahmadi, Amir; Rezazadeh, Saman; Faraji, Reza; Amid, Sima; O'Connell, Tim; Heilbron, Brett; Leipsic, Jonathon; Taylor, Carolyn M
2014-02-01
The objective of this study was to assess whether sex differences exist in plaque burden and plaque subtype as assessed by coronary computed tomography angiography (CCTA). The study cohort included 937 consecutive patients who underwent CCTA between 2008 and 2010. Stenosis was quantified using the Society of Cardiovascular Computed Tomography stenosis grading scale and a total stenosis score (TSS) was generated. Plaque morphology (PM) was reported as predominantly calcified (CP), noncalcified (NCP), or mixed (MP) plaque, and CP, NCP, and MP percentages were calculated. On multivariate analysis, men were significantly more likely to have plaque (65.9% of men vs. 44.6% of women, p<0.001), at least one segment with ≥50% stenosis (22.7% of men vs. 10.3% of women, p<0.001) and higher TSS (mean score=2.81 for men vs. 1.58 for women, p<0.001). Sex was the strongest predictor in all models (odds ratio [OR]=2.55, 95% confidence interval [CI] 1.78-3.67, p<0.001 for any plaque; OR=2.48, 95% CI 1.48-4.16, p<0.01 for segments with ≥50% stenosis; β=1.46, 95% CI 0.69-2.22, p<0.001 for TSS). Among patients with coronary plaque present, no significant sex differences in PM were found. Sex was the strongest risk factor for the presence and extent of plaque. Significant sex differences in PM did not exist.
Fuster, Rafael García; Montero Argudo, José A; Albarova, Oscar Gil; Hornero Sos, Fernando; Cánovas López, Sergio; Bueno Codoñer, María; Buendía Miñano, José A; Rodríguez Albarran, Ignacio
2005-06-01
Ventricular dysfunction and high hypertrophy may influence surgical outcome in aortic stenosis. Our aim was to determine whether an excessive left ventricular mass index (LVMI) discriminates different risk profiles in aortic stenosis with low ventricular ejection fraction (LVEF). Three hundred and thirty-nine patients with severe aortic stenosis underwent valve replacement (Mar-1994 and Nov-2001). LVMI values over the superior quartile were considered increased. Mortality models were constructed in global and LVEF
Clinical implications of differentiating between types of post-tracheostomy tracheal stenosis
Shin, Beomsu; Kim, Kang; Eom, Jung Seop; Song, Won Jun; Kim, Hojoong
2017-01-01
Background Post-tracheostomy tracheal stenosis (PTTS) can be divided into four types according to stenosis mechanism and site: subglottic, stoma, cuff, and tip granuloma. However, there is little information available regarding clinical differences among types of PTTS; therefore, we evaluated the clinical differences between these types. Methods We retrospectively evaluated 99 PTTS patients who underwent interventional bronchoscopy between 2004 and 2014. Patients were divided into two groups according to pathophysiological similarities as follows: subglottic or stoma type (n=59) and cuff or tip type (n=40). Results There were no differences in baseline characteristics between groups. However, silicone stents were more frequently needed in patients with subglottic or stoma type stenosis (76%) than those with cuff or tip type stenosis (55%, P=0.031) to maintain airway patency. On the contrary, permanent tracheostomy was more frequently performed in patients with cuff or tip type stenosis (50%) than those with subglottic or stoma type stenosis (19%, P=0.002). Finally, successful removal of the tracheostomy tube without surgery and procedure- or disease-related mortality were more frequently achieved in patients with subglottic or stoma type stenosis (71%) than those with cuff or tip type stenosis (45%, P=0.012). Conclusions Although there were no significant differences in baseline characteristics between PTTS types, patients with subglottic or stoma type stenosis had more favorable outcomes than those with cuff or tip type stenosis. Therefore, it could be important to distinguish between types of PTTS when assessing prognosis. PMID:29268510
Dalainas, I; Avgerinos, E D; Daskalopoulos, M E; Papapetrou, A; Papasideris, C P; Katsikas, V; Xiromeritis, K; Moulakakis, K; Gianakopoulos, T; Liapis, C D
2012-02-01
The ipsilateral external carotid artery (ECA) can potentially provide an important collateral pathway for cerebral blood flow in the presence of occlusion or severe stenosis of the internal carotid artery (ICA), recovering up to 15% of the middle cerebral arterial flow. The aim of the study is to elucidate the role of ECA in cerebral flow of patients with total ICA occlusion. Retrospective study of prospectively collected data of 139 patients with total ICA occlusions. The patients were divided to symptomatic and asymptomatic and were categorized in four subgroups according to the stenosis rates: A) ipsilateral ECA<70% and contralateral internal carotid artery stenosis <70%; B) ipsilateral ECA stenosis <70% and contralateral internal carotid artery stenosis ≥70%; C) ipsilateral ECA stenosis ≥70% and contralateral ICA stenosis <70%; D) ipsilateral ECA stenosis ≥70% and contralateral ICA stenosis ≥75%. Fifty eight (41.7%) patients were asymptomatic. The highest rate (48.2%) of asymptomatic patients was in Group A. Among patients with strokes, the highest rate belonged in groups C and D (44.4% and 50% respectively) where ipsilateral ECA stenosis was ≥70% irrespectively of the contralateral ICA patency. Ipsilateral external carotid artery stenosis ≥70% proved to be and independent risk factor for symptom presentation (P=0.013). The study reveals the significant role of ECA patency in cerebral flow in patients with ICA occlusion.
Evolving role of mitomycin-C laryngology
NASA Astrophysics Data System (ADS)
Richards, Steven V.; Garrett, C. Gaelyn
2001-05-01
Topical mitomycin-C, a chemotherapeutic agent and a fibroblast inhibitor, has been successfully used in larynx, primarily to treat stenosis. Subglottic, tracheal, and anterior glottic stenosis have all shown promising results in a canine model. Less favorable results have been obtained when topical mitomycin-C is used on the vocal folds following surgical excision of mucosa. In the vocal fold studies, laryngeal videostroboscopy revealed diminished mucosal wave vibration in the vocal folds treated with mitomycin-C as well as a more atrophic appearance to the vibratory surface. The tissue treated with mitomycin-C showed fewer fibroblasts and less collagen. However, inflammatory infiltrate was not significantly different between the treated and untreated tissue. These results are consistent with the known suppression of fibroblast proliferation by mitomycin-C. In contrast to the positive effects of mitomycin-C on stenosis, the observed decrease in the healing response in the vocal fold had negative consequences on vocal fold vibratory pattern.
Endoscopic laser treatment of subglottic and tracheal stenosis
NASA Astrophysics Data System (ADS)
Correa, Alex J.; Garrett, C. Gaelyn; Reinisch, Lou
1999-06-01
The ideal laser produces discrete wounds in a reproducible manner. The CO2 laser with its 10.6 micron wavelength is highly absorbed by water, its energy concentrated at the point of impact and the longer wavelength creates less scatter in tissue. The development of binocular endoscopic delivery system for use with binocular microlaryngoscopes have aided in using CO2 laser to treat patients with subglottic and tracheal stenosis. Often, patients with these disease processes require multiple endoscopic or open reconstructive procedures and my ultimately become tracheotomy dependent. The canine model of subglottic stenosis that has been develop allows testing of new agents as adjuncts to laser treatment. Mitomycin-C is an antibiotic with antitumor activity used in chemotherapy and also in ophthalmologic surgery due to its known inhibition of fibroblast proliferation. Current studies indicate this drug to have significant potential for improving our current management of this disease process.
Esophageal stenosis in a child presenting a de novo 7q terminal deletion.
Zen, Paulo R G; Riegel, Mariluce; Rosa, Rafael F M; Pinto, Louise L C; Graziadio, Carla; Schwartz, Ida V D; Paskulin, Giorgio A
2010-01-01
We report on the first case of a child with a de novo 7q terminal deletion [46,XX,del(7)(q35 → qter)] presenting esophageal stenosis. This cytogenetic abnormality was confirmed by FISH, using subtelomeric probes, and by a whole-genome array-CGH assay. The child also had phenotypic features previously described in patients with a similar deletion, as growth retardation, microcephaly, coloboma of papilla, ptosis, hearing loss, urinary tract anomalies, partial agenesis of sacrum, hypotonia and neuropsychomotor delay. The odontoid hypoplasia identified, in similarity with the esophageal stenosis, represents an uncommon finding. This report is also the first clinical description of a patient with an abnormality involving the sonic hedgehog gene and an esophageal alteration. It is discussed the possibility of a specific association between them, according to some results observed in studies with animal models. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Decision analysis in clinical cardiology: When is coronary angiography required in aortic stenosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Georgeson, S.; Meyer, K.B.; Pauker, S.G.
1990-03-15
Decision analysis offers a reproducible, explicit approach to complex clinical decisions. It consists of developing a model, typically a decision tree, that separates choices from chances and that specifies and assigns relative values to outcomes. Sensitivity analysis allows exploration of alternative assumptions. Cost-effectiveness analysis shows the relation between dollars spent and improved health outcomes achieved. In a tutorial format, this approach is applied to the decision whether to perform coronary angiography in a patient who requires aortic valve replacement for critical aortic stenosis.
Increased Expression of Interleukin-18 mRNA is Associated with Carotid Artery Stenosis
Arapi, Berk; Bayoğlu, Burcu; Cengiz, Müjgan; Dirican, Ahmet; Deser, Serkan Burç; Junusbekov, Yerik; Arslan, Caner
2018-05-29
Carotid artery stenosis is the atherosclerotic narrowing of the proximal internal carotid artery and one of the primary causes of stroke. Elevated expression of the pleiotropic proinflammatory cytokine interleukin-18 has been demonstrated in human atherosclerotic plaques. To investigate whether the mRNA expression levels of interleukin-18 and interleukin-18-binding protein and interleukin-18 −137 G/C (rs187238) variants are associated with carotid artery stenosis development. Case-control study. The mRNA expression levels of interleukin-18 and interleukin-18-binding protein and interleukin-18 rs187238 variants were evaluated by quantitative real-time polymerase chain reaction and real-time polymerase chain reaction, respectively, in the peripheral blood mononuclear cells of 70 patients with carotid artery stenosis (36 symptomatic, 34 asymptomatic) and 75 healthy controls. Interleukin-18 mRNA expression was significantly increased in carotid artery stenosis patients compared to that in healthy controls (p=0.01). However, no significant difference was observed between interleukin-18-binding protein mRNA expression levels in patients with carotid artery stenosis and those in controls (p=0.101). Internal carotid artery stenosis severity was significantly higher in symptomatic patients than that in asymptomatic patients (p<0.001). A significant relationship was identified between interleukin-18 expression and internal carotid artery stenosis severity in patients with carotid artery stenosis (p=0.051). Interleukin-18 rs187238 polymorphism genotype frequencies did not significantly differ between patients with carotid artery stenosis and controls (p=0.246). A significant difference was identified between interleukin-18-binding protein gene expression and symptomatic and asymptomatic patients (p=0.026), but there was no difference in interleukin-18 expression between the symptomatic and asymptomatic subgroups (p=0.397). Interleukin-18 mRNA expression may affect carotid artery stenosis etiopathogenesis and internal carotid artery stenosis severity and also may play a mechanistic role in the pathogenesis of carotid artery stenosis, influencing the appearance of symptoms.
Isohata, Noriyuki; Naritaka, Yoshihiko; Asaka, Shinichi; Shimakawa, Takeshi; Miyaki, Akira; Yamaguchi, Kentaro; Murayama, Minoru; Katsube, Takao; Ogawa, Kenji
2011-11-01
We herein report three cases of the malignant esophageal stenosis successfully treated with the Niti-S™ esophageal stent. CASE 1: The hilar lung cancer and its mediastinal lymph node metastasis pressed the esophagus extramurally and caused the marked stenosis. CASE 2: A metastatic lymph node along the left laryngeal nerve caused the stenosis of the trachea. A primary esophageal lesion located at the middle thoracic esophagus also caused the marked stenosis. At first, tracheal stent was placed because of dyspnea, and two weeks later, we placed an esophageal stent. Case 3: Esophageal cancer at lower thoracic esophagus after definitive radiation therapy caused the marked stenosis. Because of the stenosis of esophago-gastric junction( EGJ), we used an esophageal stent with a long cover in order to prevent a reflux into the esophagus. This new Niti-STM esophageal stent was easy to place at the stenosis without difficulty using a conventional device. The symptom was improved immediately for each case. We hope this new device will be used widely.
Degenerative lumbar spinal stenosis: correlation with Oswestry Disability Index and MR imaging.
Sirvanci, Mustafa; Bhatia, Mona; Ganiyusufoglu, Kursat Ali; Duran, Cihan; Tezer, Mehmet; Ozturk, Cagatay; Aydogan, Mehmet; Hamzaoglu, Azmi
2008-05-01
Because neither the degree of constriction of the spinal canal considered to be symptomatic for lumbar spinal stenosis nor the relationship between the clinical appearance and the degree of a radiologically verified constriction is clear, a correlation of patient's disability level and radiographic constriction of the lumbar spinal canal is of interest. The aim of this study was to establish a relationship between the degree of radiologically established anatomical stenosis and the severity of self-assessed Oswestry Disability Index in patients undergoing surgery for degenerative lumbar spinal stenosis. Sixty-three consecutive patients with degenerative lumbar spinal stenosis who were scheduled for elective surgery were enrolled in the study. All patients underwent preoperative magnetic resonance imaging and completed a self-assessment Oswestry Disability Index questionnaire. Quantitative image evaluation for lumbar spinal stenosis included the dural sac cross-sectional area, and qualitative evaluation of the lateral recess and foraminal stenosis were also performed. Every patient subsequently answered the national translation of the Oswestry Disability Index questionnaire and the percentage disability was calculated. Statistical analysis of the data was performed to seek a relationship between radiological stenosis and percentage disability recorded by the Oswestry Disability Index. Upon radiological assessment, 27 of the 63 patients evaluated had severe and 33 patients had moderate central dural sac stenosis; 11 had grade 3 and 27 had grade 2 nerve root compromise in the lateral recess; 22 had grade 3 and 37 had grade 2 foraminal stenosis. On the basis of the percentage disability score, of the 63 patients, 10 patients demonstrated mild disability, 13 patients moderate disability, 25 patients severe disability, 12 patients were crippled and three patients were bedridden. Radiologically, eight patients with severe central stenosis and nine patients with moderate lateral stenosis demonstrated only minimal disability on percentage Oswestry Disability Index scores. Statistical evaluation of central and lateral radiological stenosis versus Oswestry Disability Index percentage scores showed no significant correlation. In conclusion, lumbar spinal stenosis remains a clinico-radiological syndrome, and both the clinical picture and the magnetic resonance imaging findings are important when evaluating and discussing surgery with patients having this diagnosis. MR imaging has to be used to determine the levels to be decompressed.
A Quantitative Study of Simulated Bicuspid Aortic Valves
NASA Astrophysics Data System (ADS)
Szeto, Kai; Nguyen, Tran; Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan
2010-11-01
Previous studies have shown that congentially bicuspid aortic valves develop degenerative diseases earlier than the standard trileaflet, but the causes are not well understood. It has been hypothesized that the asymmetrical flow patterns and turbulence found in the bileaflet valves together with abnormally high levels of strain may result in an early thickening and eventually calcification and stenosis. Central to this hypothesis is the need for a precise quantification of the differences in the strain rate levels between bileaflets and trileaflet valves. We present here some in-vitro dynamic measurements of the spatial variation of the strain rate in pig aortic vales conducted in a left ventricular heart flow simulator device. We measure the strain rate of each leaflet during the whole cardiac cycle using phase-locked stereoscopic three-dimensional image surface reconstruction techniques. The bicuspid case is simulated by surgically stitching two of the leaflets in a normal valve.
NASA Astrophysics Data System (ADS)
Petruse, Radu Emanuil; Batâr, Sergiu; Cojan, Adela; Maniţiu, Ioan
2014-11-01
Coronary computed tomography angiography (CCTA) allows coronary artery visualization and the detection of coronary stenoses. In addition; it has been suggested as a novel, noninvasive modality for coronary atherosclerotic plaque detection, characterization, and quantification. Accurate identification of coronary plaques is challenging, especially for the noncalcified plaques, due to many factors such as the small size of coronary arteries, reconstruction artifacts caused by irregular heartbeats, beam hardening, and partial volume averaging. The development of 16, 32, 64 and the latest 320 row multidetector CT not only increases the spatial and the temporal resolution significantly, but also increases the number of images to be interpreted by radiologists substantially. Radiologists have to visually examine each coronary artery for suspicious stenosis using visualization tools such as multiplanar reformatting (MPR) and curved planar reformatting (CPR) provided by the review workstation in clinical practice
Wang, Yan; Zhang, Jin; Qain, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang
2016-08-01
Intracranial arterial stenosis is a common cause of ischemic stroke in Asians. We therefore sought to explore the relationship of brachial-ankle pulse wave velocity and intracranial arterial stenosis in 834 stroke-free hypertensive patients. Intracranial arterial stenosis was evaluated through computerized tomographic angiography. Brachial-ankle pulse wave velocity was measured by an automated cuff device. The top decile of brachial-ankle pulse wave velocity was significantly associated with intracranial arterial stenosis (P = .027, odds ratio = 1.82; 95% confidence interval: 1.07-3.10). The patients with the top decile of brachial-ankle pulse wave velocity showed 56% higher risk for the presence of intracranial arterial stenosis to the whole population, which was more significant in patients younger than 65 years old. We also found that brachial-ankle pulse wave velocity related to both intracranial arterial stenosis and homocysteine. Our study showed the association of brachial-ankle pulse wave velocity with asymptomatic intracranial arterial stenosis in hypertension patients, especially in relative younger subjects. Brachial-ankle pulse wave velocity might be a relatively simple and repeatable measurement to detect hypertension patients in high risk of intracranial arterial stenosis. Copyright © 2016. Published by Elsevier Inc.
Screening for Carotid Artery Stenosis
... build up and harden the arteries, limiting the flow of blood to the brain. Facts About Carotid Artery Stenosis Carotid artery stenosis is one of many risk factors for stroke, a leading cause of death and disability in the United States. However, carotid artery stenosis is uncommon—about ½ ...
Asymptomatic carotid stenosis is associated with cognitive impairment.
Lal, Brajesh K; Dux, Moira C; Sikdar, Siddhartha; Goldstein, Carly; Khan, Amir A; Yokemick, John; Zhao, Limin
2017-10-01
Cerebrovascular risk factors (eg, hypertension, coronary artery disease) and stroke can lead to vascular cognitive impairment. The Asymptomatic Carotid Stenosis and Cognitive Function study evaluated the isolated impact of asymptomatic carotid stenosis (no prior ipsilateral or contralateral stroke or transient ischemic attack) on cognitive function. Cerebrovascular hemodynamic and carotid plaque characteristics were analyzed to elucidate potential mechanisms affecting cognition. There were 82 patients with ≥50% asymptomatic carotid stenosis and 62 controls without stenosis but matched for vascular comorbidities who underwent neurologic, National Institutes of Health Stroke Scale, and comprehensive neuropsychological examination. Overall cognitive function and five domain-specific scores were computed. Duplex ultrasound with Doppler waveform and B-mode imaging defined the degree of stenosis, least luminal diameter, plaque area, and plaque gray-scale median. Breath-holding index (BHI) and microembolization were measured using transcranial Doppler. We assessed cognitive differences between stenosis patients and control patients and of stenosis patients with low vs high BHI and correlated cognitive function with microembolic counts and plaque characteristics. Stenosis and control patients did not differ in vascular risk factors, education, estimated intelligence, or depressive symptoms. Stenosis patients had worse composite cognitive scores (P = .02; Cohen's d = 0.43) and domain-specific scores for learning/memory (P = .02; d = 0.42) and motor/processing speed (P = .01; d = 0.65), whereas scores for executive function were numerically lower (P = .08). Approximately 49.4% of all stenosis patients were impaired in at least two cognitive domains. Precisely 50% of stenosis patients demonstrated a reduced BHI. Stenosis patients with reduced BHI performed worse on the overall composite cognitive score (t = -2.1; P = .02; d = 0.53) and tests for learning/memory (t = -2.7; P = .01; d = 0.66). Cognitive function did not correlate with measures of plaque burden (degree of stenosis, least luminal diameter, and plaque area) or with plaque gray-scale median. Asymptomatic carotid stenosis is associated with cognitive impairment independent of known vascular risk factors for vascular cognitive impairment. Approximately 49.4% of these patients demonstrate impairment in at least two neuropsychological domains. The deficit is driven primarily by reduced motor/processing speed and learning/memory and is mild to moderate in severity. The mechanism for impairment is likely to be hemodynamic as evidenced by reduced cerebrovascular reserve and the likely result of hypoperfusion from a pressure drop across the stenosis in the presence of inadequate collateralization. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Valvar stenosis in truncus arteriosus.
Gerlis, L M; Wilson, N; Dickinson, D F; Scott, O
1984-01-01
Twenty three morphological specimens of truncus arteriosus were examined for evidence of stenosis of the semilunar valve. One third showed good evidence of stenosis as judged by careful measurement of the valve orifice, the valve ring, and the maximum diameter of the truncus. Correlation with measured pressure gradients was poor, but angiography and cross sectional echocardiography were better predictors of stenosis. Stenosis was invariably associated with cusp dysplasia and was more common in valves with two or four cusps. Images PMID:6477783
Lu, Qixiu; Liu, Houlin
2015-03-01
The main objective of this study is to investigate the relationship between ascending aorta elasticity and the severity of coronary artery stenosis in essential hypertensive patients with coronary heart disease (CHD) using M-mode and tissue Doppler echocardiography. A total of 184 hypertensive patients with CHD were enrolled. Patients were divided into three groups based on the severity of coronary stenosis measured by coronary arteriography (CAG): slight stenosis (group 1), moderate stenosis (group 2) and serious stenosis (group 3). M-mode and tissue Doppler echocardiography were performed, and elasticity indexes of ascending aorta including stiffness index, distensibility index, and S wave speed of anterior wall were calculated and correlated with the severity of coronary stenosis. Ascending aorta stiffness index was increased, whereas distensibility index and S wave speed of anterior wall were decreased in moderate and severe stenosis groups compared with slight stenosis group (P < 0.01). Elasticity indexes change in a stepwise pattern with the narrowness of coronary artery, and there was a significant correlation between aortic elasticity and severity of coronary artery by Pearson correlation analysis (P < 0.01). Elasticity indexes of ascending aorta correlate well with severity of coronary stenosis. Elasticity indexes of ascending aorta can serve as predictors for coronary arterial lesion in hypertensive patients.
Stenosis differentially affects subendocardial and subepicardial arterioles in vivo.
Merkus, D; Vergroesen, I; Hiramatsu, O; Tachibana, H; Nakamoto, H; Toyota, E; Goto, M; Ogasawara, Y; Spaan, J A; Kajiya, F
2001-04-01
The presence of a coronary stenosis results primarily in subendocardial ischemia. Apart from the decrease in coronary perfusion pressure, a stenosis also decreases coronary flow pulsations. Applying a coronary perfusion system, we compared the autoregulatory response of subendocardial (n = 10) and subepicardial (n = 12) arterioles (<120 microm) after stepwise decreases in coronary arterial pressure from 100 to 70, 50, and 30 mmHg in vivo in dogs (n = 9). Pressure steps were performed with and without stenosis on the perfusion line. Maximal arteriolar diameter during the cardiac cycle was determined and normalized to its value at 100 mmHg. The initial decrease in diameter during reductions in pressure was significantly larger at the subendocardium. Diameters of subendocardial and subepicardial arterioles were similar 10--15 s after the decrease in pressure without stenosis. However, stenosis decreased the dilatory response of the subendocardial arterioles significantly. This decreased dilatory response was also evidenced by a lower coronary inflow at similar average pressure in the presence of a stenosis. Inhibition of nitric oxide production with N(G)-monomethyl-L-arginine abrogated the effect of the stenosis on flow. We conclude that the decrease in pressure caused by a stenosis in vivo results in a larger decrease in diameter of the subendocardial arterioles than in the subepicardial arterioles, and furthermore stenosis selectively decreases the dilatory response of subendocardial arterioles. These two findings expand our understanding of subendocardial vulnerability to ischemia.
Quantitative evaluation of the lumbosacral sagittal alignment in degenerative lumbar spinal stenosis
Makirov, Serik K.; Jahaf, Mohammed T.; Nikulina, Anastasia A.
2015-01-01
Goal of the study This study intends to develop a method of quantitative sagittal balance parameters assessment, based on a geometrical model of lumbar spine and sacrum. Methods One hundred eight patients were divided into 2 groups. In the experimental group have been included 59 patients with lumbar spinal stenosis on L1-5 level. Forty-nine healthy volunteers without history of any lumbar spine pathlogy were included in the control group. All patients have been examined with supine MRI. Lumbar lordosis has been adopted as circular arc and described either anatomical (lumbar lordosis angle), or geometrical (chord length, circle segment height, the central angle, circle radius) parameters. Moreover, 2 sacral parameters have been assessed for all patients: sacral slope and sacral deviation angle. Both parameters characterize sacrum disposition in horizontal and vertical axis respectively. Results Significant correlation was observed between anatomical and geometrical lumbo-sacral parameters. Significant differences between stenosis group and control group were observed in the value of the “central angle” and “sacral deviation” parameters. We propose additional parameters: lumbar coefficient, as ratio of the lordosis angle to the segmental angle (Kl); sacral coefficient, as ratio of the sacral tilt (ST) to the sacral deviation (SD) angle (Ks); and assessment modulus of the mathematical difference between sacral and lumbar coefficients has been used for determining lumbosacral balance (LSB). Statistically significant differences between main and control group have been obtained for all described coefficients (p = 0.006, p = 0.0001, p = 0.0001, accordingly). Median of LSB value of was 0.18 and 0.34 for stenosis and control groups, accordingly. Conclusion Based on these results we believe that that spinal stenosis is associated with an acquired deformity that is measureable by the described parameters. It's possible that spinal stenosis occurs in patients with an LSB of 0.2 or less, so this value can be predictable for its development. It may suggest that spinal stenosis is more likely to occur in patients with the spinal curvature of this type because of abnormal distribution of the spine loads. This fact may have prognostic significance for develop vertebral column disease and evaluation of treatment results. PMID:26767160
External carotid artery stenosis after internal and common carotid stenting.
Siracuse, Jeffrey J; Epelboym, Irene; Li, Boyangzi; Hoque, Rahima; Catz, Diana; Morrissey, Nicholas J
2015-04-01
The external carotid artery (ECA) can be an important collateral for cerebral perfusion in the presence of severe internal carotid artery (ICA) disease. ICA stenting that covers the ECA origin may put the ECA at increased risk of stenosis. Our objective was to determine the rate of ECA stenosis secondary to ICA stenting, determine predictive factors, and describe any subsequent associated symptoms. We retrospectively reviewed clinical data on all ICA stents crossing the origin of the ECA placed by vascular surgeons at our institution. We analyzed patient demographics, comorbidities, stent type and sizes, as well as medication profile to determine predictors of ECA stenosis. Between 2005 and 2013, there were 72 (out of 119 total ICA stenting) patients (mean age 71, 68% male) who underwent placement of ICA stents that also crossed the origin of the ECA. Six patients (8.3%) had a significantly increased ECA stenosis postprocedure. There were no occlusions. All patients with ECA stenosis maintained patency of their ICA stent and were asymptomatic. Age, gender, comorbidities, stent type and size, and medication profile were not associated with ECA stenosis after stenting. ECA stenosis after ICA stenting covering the ECA origin is uncommon and not clinically significant in patients with patent ICA stents. The clinical significance of concurrent ECA and ICA stenosis after stenting is unclear as it is not captured here. The potential for ECA stenosis should not deter stenting across the ECA origin if necessary. Patient and stent factors are not predictive of ECA stenosis. Copyright © 2015 Elsevier Inc. All rights reserved.
A dual-phantom system for validation of velocity measurements in stenosis models under steady flow.
Blake, James R; Easson, William J; Hoskins, Peter R
2009-09-01
A dual-phantom system is developed for validation of velocity measurements in stenosis models. Pairs of phantoms with identical geometry and flow conditions are manufactured, one for ultrasound and one for particle image velocimetry (PIV). The PIV model is made from silicone rubber, and a new PIV fluid is made that matches the refractive index of 1.41 of silicone. Dynamic scaling was performed to correct for the increased viscosity of the PIV fluid compared with that of the ultrasound blood mimic. The degree of stenosis in the models pairs agreed to less than 1%. The velocities in the laminar flow region up to the peak velocity location agreed to within 15%, and the difference could be explained by errors in ultrasound velocity estimation. At low flow rates and in mild stenoses, good agreement was observed in the distal flow fields, excepting the maximum velocities. At high flow rates, there was considerable difference in velocities in the poststenosis flow field (maximum centreline differences of 30%), which would seem to represent real differences in hydrodynamic behavior between the two models. Sources of error included: variation of viscosity because of temperature (random error, which could account for differences of up to 7%); ultrasound velocity estimation errors (systematic errors); and geometry effects in each model, particularly because of imperfect connectors and corners (systematic errors, potentially affecting the inlet length and flow stability). The current system is best placed to investigate measurement errors in the laminar flow region rather than the poststenosis turbulent flow region.
Bronchoscopic management of benign bronchial stenosis by electrocautery and balloon dilatation.
Garg, M; Gogia, Pratibha; Manoria, P; Goyal, R
2012-01-01
Benign bronchial stenosis is managed by surgical or bronchoscopic methods. Although surgical approach is definitive, it is technically demanding and is costlier than bronchoscopic treatment. Here, we report the case of a 27-year-old female patient with symptomatic benign bronchial stenosis of the left main bronchus. The stenosis was dilated successfully through a fibreoptic bronchoscope by electrocautery followed by balloon bronchoplasty and application of mitomycin-C. On follow up, there was no evidence of re-stenosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, T; Ding, H; Lipinski, J
2015-06-15
Purpose: To develop a physics-based model for accurate quantification of the cross-sectional area (CSA) of coronary arteries in CT angiography by measuring the integrated density to account for the partial volume effect. Methods: In this technique the integrated density of the object as compared with its local background is measured to account for the partial volume effect. Normal vessels were simulated as circles with diameters in the range of 0.1–3mm. Diseased vessels were simulated as 2, 3, and 4mm diameter vessels with 10–90% area stenosis, created by inserting circular plaques. A simplified two material model was used with the lumenmore » as 8mg/ml Iodine and background as lipid. The contrast-to-noise ratio between lumen and background was approximately 26. Linear fits to the known CSA were calculated. The precision and accuracy of the measurement were quantified using the root-mean-square fit deviations (RMSD) and errors to the known CSA (RMSE). Results compared to manual segmentation of the vessel lumen. To assess the impact of random variations, coefficients of variation (CV) from 10 simulations for each vessel were computed to determine reliability. Measurements with CVs less than 10% were considered reliable. Results: For normal vessels, the precision and accuracy of the integrated density technique were 0.12mm{sup 2} and 0.28mm{sup 2}, respectively. The corresponding results for manual segmentation were 0.27mm{sup 2} and 0.43mm{sup 2}. For diseased vessels, the precision and accuracy of the integrated density technique were 0.14mm{sup 2} and 0.19mm{sup 2}. Corresponding results for manual segmentation were 0.42mm{sup 2} and 0.71mm{sup 2}. Reliable CSAs were obtained for normal vessels with diameters larger than 1 mm and for diseased vessels with area as low as 1.26mm2. Conclusion: The CSA based on integrated density showed improved precision and accuracy as compared with manual segmentation in simulation. These results indicate the potential of using integrated density to quantify CSA of coronary arteries in CT angiography.« less
NASA Astrophysics Data System (ADS)
Powell, Janet L.; Poepping, Tamie L.
2011-03-01
An in vitro flow system has been used to assess the flow disturbances downstream of the stenosis in a family of seven carotid bifurcation phantoms modelling varying plaque build-up both axially symmetrically (concentrically) and asymmetrically (eccentrically). Radio frequency data were collected for 10 s at each of over 1000 sites within each model, and a sliding 1024-point FFT is applied to the data to extract the Doppler spectrum every 12 ms. From this, the ensemble average over 10 cardiac cycles of the spectral mean velocity, and the root mean square over these same 10 cardiac cycles - the turbulence intensity (TI), can be obtained as a function of an ensemble averaged cardiac cycle at each spatial point in all phantoms. TI was investigated by looking at the average over a 25 mm2 square region of interest in the ICA centered 2 cm distal to the apex of the bifurcation. TI in the region of interest increased with stenosis severity; at 23ms following peak systole, the time point when TI was maximal for the majority of models, this ranged from 2.4+/-0.1 cm/s in the non-diseased model to 6.6+/-0.3, 16.0+/-1.4 and 26.1+/-1.3 cm/s in the 30, 50 and 70% concentrically stenosed (by NASCET criteria) models, respectively. Similarly, TI was 8.3+/-0.7, 19.9+/-1.1, and 26.2+/-1.2 cm/s in the 30, 50 and 70% eccentrically stenosed models, respectively. Differences in TI between models, both in increasing stenosis severity and between eccentricities, were statistically different except between the 70% concentric and eccentric models.
Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A.; Osman, Nael F.
2009-01-01
Background High-dose dobutamine stress magnetic resonance imaging (DS-MRI) is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, Strain-Encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC to that provided by conventional wall motion analysis for the detection of inducible ischemia during DS-MRI. Methods and Results Stress induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent DS-MRI in a clinical 1.5T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (≥50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86/101 versus 71/101 diseased coronary vessels (p<0.01 versus cine), and showed normal strain response in 189/202 versus 194/202 vessels with <50% stenosis (p=NS versus cine). On a patient level, SENC detected inducible ischemia in 63/64 versus 55/64 patients with CAD (p<0.05 versus cine), and showed normal strain response in 32/37 versus 34/37 patients without CAD (p=NS versus cine).Quantification analysis demonstrated a significant correlation between strain rate reserve (SRreserve) and coronary artery stenosis severity (r²=0.56, p<0.001), and a cut-off value of SRreserve=1.64 deemed as a highly accurate marker for the detection of stenosis≥50% (AUC=0.96, SE=0.01, 95% CI = 0.94–0.98, p<0.001). Conclusions The direct color-coded visualization of strain on MR-images is a useful adjunct for DS-MRI, which provides incremental value for the detection of CAD compared to conventional wall motion readings on cine images. PMID:19808579
Neutrophil extracellular traps promote deep vein thrombosis in mice
Brill, A.; Fuchs, T.A.; Savchenko, A.S.; Thomas, G.M.; Martinod, K.; De Meyer, S.F.; Bhandari, A.A.; Wagner, D.D.
2011-01-01
Summary Background Upon activation, neutrophils can release nuclear material known as neutrophil extracellular traps (NETs), which were initially described as a part of antimicrobial defense. Extracellular chromatin was recently reported to be pro-thrombotic in vitro and to accumulate in plasma and thrombi of baboons with experimental deep vein thrombosis (DVT). Objective To explore the source and role of extracellular chromatin in DVT. Methods We used an established murine model of DVT induced by flow restriction (stenosis) in the inferior vena cava (IVC). Results We demonstrate that the levels of extracellular DNA increase in plasma after 6 h IVC stenosis, compared to sham-operated mice. Immunohistochemical staining revealed the presence of Gr-1-positive neutrophils in both red (RBC-rich) and white (platelet-rich) parts of thrombi. Citrullinated histone H3 (CitH3), an element of NETs’ structure, was present only in the red part of thrombi and was frequently associated with the Gr-1 antigen. Immunofluorescent staining of thrombi showed proximity of extracellular CitH3 and von Willebrand factor (VWF), a platelet adhesion molecule crucial for thrombus development in this model. Infusion of Deoxyribonuclease 1 (DNase 1) protected mice from DVT after 6 h and also 48 h IVC stenosis. Infusion of an unfractionated mixture of calf thymus histones increased plasma VWF and promoted DVT early after stenosis application. Conclusions Extracellular chromatin, likely originating from neutrophils, is a structural part of a venous thrombus and both the DNA scaffold and histones appear to contribute to the pathogenesis of DVT in mice. NETs may provide new targets for DVT drug development. PMID:22044575
NASA Astrophysics Data System (ADS)
Schiavazzi, Daniele E.; Kung, Ethan O.; Dorfman, Adam L.; Hsia, Tain-Yen; Baretta, Alessia; Arbia, Gregory; Marsden, Alison L.
2013-11-01
Congenital heart diseases such as hypoplastic left heart syndrome annually affect about 3% of births in the US alone. Surgical palliation of single ventricle patients is performed in stages. Consequently to the stage 2 surgical procedure or other previous conditions, a stenosis of the left pulmonary artery (LPA) is often observed, raising the clinical question of whether or not it should be treated. The severity of stenoses are commonly assessed through geometric inspection or catheter in-vivo pressure measurements with limited quantitative information about patient-specific physiology. The present study uses a multiscale CFD approach to provide an assessment of the severity of LPA stenoses. A lumped parameter 0D model is used to simulate stage 2 circulation, and parameters are automatically identified accounting for uncertainty in the clinical data available for a cohort of patients. The importance of the latter parameters, whether alone or in groups, is also ranked using forward uncertainty propagation methods. Various stenosis levels are applied to the three-dimensional SVC-PA junction model using a dual mesh-morphing approach. Traditional assessments methodologies are compared to the results of our findings and critically discussed.
Albalbissi, Kais A; Burress, Jonathan W; Garcia, Israel D; Iskandar, Said B
2009-02-01
Mitral stenosis is a well-described valvular heart disease. We report a 68-year-old patient with an unusual presentation of mitral stenosis. He presented with recurrent episodes of hemorrhagic pleural effusion. Afterwards, an extensive atrial thrombosis complicated his course of illness. We will discuss how the clinical presentation of mitral stenosis is mainly dictated by the underlying pathophysiology of the disease. Also, the need for anticoagulation in the setting of mitral stenosis is often linked to the presence of atrial fibrillation. We will discuss the independent risk factors for thromboembolism in the setting of mitral stenosis. Finally, a review of the current recommendation for anticoagulation is conferred.
Uçar, Tayfun; Tutar, Ercan; Atalay, Semra
2008-01-01
We give details of a sporadic case with congenital supravalvular aortic stenosis associated with critical stenosis of the left carotid artery, and severe stenosis of the innominate artery at their origins as well as excessive dilatations of both the right and the left coronary arteries.
Zhu, Runxiu; Yan, Zhongrui; Zheng, Shouhuan; Wang, Jingwei; Huo, Jia; Liu, Yunlin; Li, Xin; Ji, Yong
2016-01-01
To investigate potential associations between carotid artery stenosis and cognitive impairment among patients with acute ischemic stroke and to provide important clinical implications. We measured the degree of carotid artery stenosis and recorded the Mini-Mental State Examination score (MMSE) at admission in 3116 acute ischemic stroke patients. The association between carotid stenosis and cognitive impairment assessed by MMSE was tested using multivariate regression analysis. Other clinical variables of interest were also studied. After adjusting for age, gender, education level, marriage, alcohol use, tobacco use, physical activity, hypertension, diabetes, hypercholesterolemia, atrial fibrillation, myocardial infarction and NIHSS (National Institutes of Health Stroke Scale) score, we found that participants with high-grade stenosis of the carotid artery had a higher likelihood of cognitive impairment compared to those without carotid artery stenosis (OR = 1.49, 95%CI: 1.05–2.11, p<0.001). Left common carotid artery stenosis was associated with cognitive impairment in the univariate analysis, although this effect did not persist after adjustment for the NIHSS score. Cognitive impairment was associated with high-grade stenosis of the right carotid artery. PMID:26751070
Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.
Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming
2014-01-01
We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.
Kander, M; Pasławska, U; Staszczyk, M; Cepiel, A; Pasławski, R; Mazur, G; Noszczyk-Nowak, A
2015-01-01
The study has focused on the retrospective analysis of cases of coexisting congenital aortic stenosis (AS) and pulmonary artery stenosis (PS) in dogs. The research included 5463 dogs which were referred for cardiological examination (including clinical examination, ECG and echocardiography) between 2004 and 2014. Aortic stenosis and PS stenosis were detected in 31 dogs. This complex defect was the most commonly diagnosed in Boxers - 7 dogs, other breeds were represented by: 4 cross-breed dogs, 2 Bichon Maltais, 3 Miniature Pinschers, 2 Bernese Mountain Dogs, 2 French Bulldogs, and individuals of following breeds: Bichon Frise, Bull Terrier, Czech Wolfdog, German Shepherd, Hairless Chinese Crested Dog, Miniature Schnauzer, Pug, Rottweiler, Samoyed, West Highland White Terrier and Yorkshire Terrier. In all the dogs, the murmurs could be heard, graded from 2 to 5 (on a scale of 1-6). Besides, in 9 cases other congenital defects were diagnosed: patent ductus arteriosus, mitral valve dysplasia, pulmonary or aortic valve regurgitation, tricuspid valve dysplasia, ventricular or atrial septal defect. The majority of the dogs suffered from pulmonary valvular stenosis (1 dog had supravalvular pulmonary artery stenosis) and subvalvular aortic stenosis (2 dogs had valvular aortic stenosis). Conclusions and clinical relevance - co-occurrence of AS and PS is the most common complex congenital heart defect. Boxer breed was predisposed to this complex defect. It was found that coexisting AS and PS is more common in male dogs and the degree of PS and AS was mostly similar.
Crawford, Jason T; Adams, William M
2002-10-01
To determine influence of vestibulovaginal stenosis, pelvic bladder, and recessed vulva on response to treatment for clinical signs of lower urinary tract disease in dogs. Retrospective study. 38 spayed female dogs. Medical records and client follow-up were reviewed for dogs evaluated via excretory urography because of clinical signs of lower urinary tract disease. Clinical signs, results of radiography, and response to surgical or medical treatment were analyzed. Clinical signs included urinary tract infection (n = 24), urinary incontinence (20), vaginitis (11), pollakiuria or stranguria (10), and perivulvar dermatitis (4). Vaginocystourethrographic findings included vestibulovaginal stenosis (n = 28), pelvic bladder (17), and ureteritis or pyelonephritis (4). Ten dogs had a vestibulovaginal ratio of < 0.20 (severe stenosis), 9 dogs had a ratio of 0.20 to 0.25 (moderate stenosis), 9 dogs had a ratio of 0.26 to 0.35 (mild stenosis), and 10 dogs had a ratio of > 0.35 (anatomically normal). Lower urinary tract infection, incontinence, and pelvic bladder were not associated with response to treatment for recessed vulva. Vestibulovaginal stenosis with a ratio < 0.20 was significantly associated negatively with response to treatment. Dogs without severe vestibulovaginal stenosis that received vulvoplasty for a recessed vulva responded well to treatment. Vestibulovaginal stenosis is likely an important factor in dogs with vestibulovaginal ratio < 0.20. Vaginectomy or resection and anastomosis should be considered in dogs with severe vestibulovaginal stenosis and signs of lower urinary tract disease.
[The cause and efficacy of benign tracheal stenosis].
Su, Zhu-quan; Wei, Xiao-qun; Zhong, Chang-hao; Chen, Xiao-bo; Luo, Wei-zhan; Guo, Wen-liang; Wang, Ying-zhi; Li, Shi-yue
2013-09-01
To analysis the causes of benign tracheal stenosis and evaluate the curative effect of intraluminal bronchoscopic treatment. 158 patients with benign tracheal stenosis in our hospital from September 2005 to September 2012 were collected to retrospectively analysis the causes and clinic features of tracheal stenosis. Interventional treatments through bronchoscopy were used to treat the benign tracheal stenosis and the curative effects were evaluated. 158 cases of benign tracheal stenosis were recruited to our study, 69.6% of them were young and middle-aged. The main causes of benign tracheal stenosis were as follows: secondary to postintubation or tracheotomy in 61.4% (97/158), tuberculosis in 16% (26/158), benign tumor in 5.1% (8/158) and other 27 cases. 94.3% patients improved in symptoms with alleviation immediately after bronchoscopic treatment, the average tracheal diameter increased form (4.22 ± 2.06) mm to (10.16 ± 2.99) mm (t = 21.48, P < 0.01), dyspnea index decreased from 2.29 ± 0.75 to 0.63 ± 0.67 (t = 19.85, P < 0.01). The recurrence rate in 1 and 3 month after interventional treatment were 38.3% and 26.8%, respectively. The cases of benign tracheal stenosis were increasing year by year. The most common cause of benign tracheal stenosis was postintubation and tracheotomy. Interventional treatments through bronchoscopy is effective in treating benign tracheal stenosis, but repeated interventional procedures may be required to maintain the favorable long-term effects.
[Endoscopic dilatation of benign colon and rectum stenosis].
Rivera Vega, Juan; Frisancho Velarde, Oscar; Cervera, Zenón; Ruiz, Edwin; Yoza, Max; Larrea, Pedro
2002-01-01
To determine the usefulness of endoscopic dilatation in dealing with benign stenosis of the anus, rectum and colon. PATIENTS AND METHODS USED: Thirty six (36) patients with stenosis, anus (8), rectum (22) and colon (6) were given endoscopic treatment using hydroneumatic balloons, electro incision (radiated cuts) or a combination of both. Rigid equipment (metal) was used for distal stenosis. Age ranged between 30 and 82 years. Twelve (12) patients were male and 24 female. The diameter of the stenosis was less than 13 mm in 18 of the patients and 11 patients carried colostomy. All 36 patients were subjected to a total of 113 dilatation sessions. The average number of sessions per patient for patients with anal stenosis was 2.5 and for patients with colorectal stenosis, 3.32. One patient with rectal stenosis required 21 sessions to achieve final objective. The result achieved was good in 31 patients, less than satisfactory in 3 patients and bad in one patient, who presented a stenosis which was over 5 cm long. We lost track of a patient in the follow up stage. Success in closing the colostomy was achieved in 9 patients, while one presented a complication due to the procedure (cervical emphysema) which remitted with medical attention. Endoscopic dilatation offers, through its different techniques, a safe and efficient method for the treatment of benign stenosis of the anus, rectum and colon and must be considered as a first class tool for the treatment of this kind of pathologies.
Hallbergson, Anna; Esch, Jesse J; Tran, Trang X; Lock, James E; Marshall, Audrey C
2016-10-01
We have taken a novel approach using oral rapamycin - sirolimus - as a medical adjunct to percutaneous therapy in patients with in-stent stenosis and high risk of right ventricular failure. Peripheral pulmonary artery stenosis can result in right ventricular hypertension, dysfunction, and death. Percutaneous pulmonary artery angioplasty and stent placement acutely relieve obstructions, but patients frequently require re-interventions due to re-stenosis. In patients with tetralogy of Fallot or arteriopathy, the problem of in-stent stenosis contributes to the rapidly recurrent disease. Rapamycin was administered to 10 patients (1.5-18 years) with peripheral pulmonary stenosis and in-stent stenosis and either right ventricular hypertension, pulmonary blood flow maldistribution, or segmental pulmonary hypertension. Treatment was initiated around the time of catheterisation and continued for 1-3 months. Potential side-effects were monitored by clinical review and blood tests. Target serum rapamycin level (6-10 ng/ml) was accomplished in all patients; eight of the nine patients who returned for clinically indicated catheterisations demonstrated reduction in in-stent stenosis, and eight of the 10 patients experienced no significant side-effects. Among all, one patient developed diarrhoea requiring drug discontinuation, and one patient experienced gastrointestinal bleeding while on therapy that was likely due to an indwelling feeding tube and this patient tolerated rapamycin well following tube removal. Our initial clinical experience supports that patients with peripheral pulmonary artery stenosis can be safely treated with rapamycin. Systemic rapamycin may provide a novel medical approach to reduce in-stent stenosis.
Lipoprotein(a) in patients with aortic stenosis: Insights from cardiovascular magnetic resonance
Vassiliou, Vassilios S.; Flynn, Paul D.; Raphael, Claire E.; Newsome, Simon; Khan, Tina; Ali, Aamir; Halliday, Brian; Studer Bruengger, Annina; Malley, Tamir; Sharma, Pranev; Selvendran, Subothini; Aggarwal, Nikhil; Sri, Anita; Berry, Helen; Donovan, Jackie; Lam, Willis; Auger, Dominique; Cook, Stuart A.; Pennell, Dudley J.; Prasad, Sanjay K.
2017-01-01
Background Aortic stenosis is the most common age-related valvular pathology. Patients with aortic stenosis and myocardial fibrosis have worse outcome but the underlying mechanism is unclear. Lipoprotein(a) is associated with adverse cardiovascular risk and is elevated in patients with aortic stenosis. Although mechanistic pathways could link Lipoprotein(a) with myocardial fibrosis, whether the two are related has not been previously explored. In this study, we investigated whether elevated Lipoprotein(a) was associated with the presence of myocardial replacement fibrosis. Methods A total of 110 patients with mild, moderate and severe aortic stenosis were assessed by late gadolinium enhancement (LGE) cardiovascular magnetic resonance to identify fibrosis. Mann Whitney U tests were used to assess for evidence of an association between Lp(a) and the presence or absence of myocardial fibrosis and aortic stenosis severity and compared to controls. Univariable and multivariable linear regression analysis were undertaken to identify possible predictors of Lp(a). Results Thirty-six patients (32.7%) had no LGE enhancement, 38 (34.6%) had midwall enhancement suggestive of midwall fibrosis and 36 (32.7%) patients had subendocardial myocardial fibrosis, typical of infarction. The aortic stenosis patients had higher Lp(a) values than controls, however, there was no significant difference between the Lp(a) level in mild, moderate or severe aortic stenosis. No association was observed between midwall or infarction pattern fibrosis and Lipoprotein(a), in the mild/moderate stenosis (p = 0.91) or severe stenosis patients (p = 0.42). Conclusion There is no evidence to suggest that higher Lipoprotein(a) leads to increased myocardial midwall or infarction pattern fibrosis in patients with aortic stenosis. PMID:28704465
Echocardiographic evaluation of aortic atheromas in patients with aortic stenosis.
Vizzardi, Enrico; D'Aloia, Antonio; Sciatti, Edoardo; Bonadei, Ivano; Gelsomino, Sandro; Lorusso, Roberto; Metra, Marco
2015-01-01
The association of aortic atheromas in patients with isolated aortic stenosis has recently been acknowledged, probably because the pathogenic mechanisms are similar. Therefore, this study evaluated the extent and severity of thoracic aortic atheromas in patients with different grades of aortic stenosis using transesophageal echocardiography. We retrospectively evaluated transesophageal echocardiographic examinations of 686 consecutive patients with a diagnosis of aortic stenosis. The prevalence and morphologic characteristics of atheromas in 3 segments of the thoracic aorta were assessed. Plaque thickness was measured at each segment, and the thickest plaque was used to establish severity. Atheromas were graded as mild, moderate, or severe according to plaque thickness (<2, 2-4, or >4 mm, respectively). Aortic stenosis was graded as mild, moderate, or severe on the basis of the gradient and anatomic aortic valve area (>1.5, 1.0-1.5, or <1.0 cm(2)). A total of 382 patients were men, and 304 were women (mean age ± SD, 74 ± 15 years); 86% of the patients had aortic atheromas. The severe stenosis group had a significantly higher rate of atheromas (95% versus 40%; P < .001) than the mild stenosis group, with more complex atheromas (52% versus 22%; P< .001). There was no significant difference in the atheroma grades between the severe and moderate stenosis groups, but moderate cases had more moderate and severe atheromas than mild cases (45% and 15% versus 19% and 3%; P < .01). This study showed a correlation in the extent of aortic atheromas across several degrees of aortic stenosis. Patients with moderate and severe stenosis had more extensive atherosclerotic atheromas than those with mild stenosis. © 2015 by the American Institute of Ultrasound in Medicine.
Cho, Young Dae; Jung, Keun-Hwa; Roh, Jae-Kyu; Kang, Hyun-Seung; Han, Moon Hee; Lim, Jeong Wook
2013-09-01
Although it is hypothesized that inflammatory signals and/or hemodynamic stress resulting from carotid disease increase the risk of aneurysm formation and growth, a relationship between intracranial aneurysms and extracranial carotid artery disease (ECAD) has not been explored. Here, we examined the characteristics of intracranial aneurysms associated with ECAD. A total of 606 consecutive patients with stenosis of 50% or more of the proximal internal carotid artery (pICA) were enrolled. Stenosis was identified by conventional angiography between January 2003 and December 2009. We determined the prevalence of intracranial aneurysms in this population. The characteristics of the aneurysms were analyzed according to the degree and laterality of stenosis. The changes in the aneurysms were tracked for the evaluation of stability. In 86 patients (14.2%), 120 aneurysms were detected in association with pICA stenosis. In this group, 97 were associated with unilateral pICA stenosis. The distribution of aneurysms was independent of the laterality of stenosis, but aneurysms were more prevalent in the contralateral side as the stenosis grade increased (P<0.001). All aneurysms with an imaging follow-up (28.9 ± 14.3 months) were stable, and the course was not affected by treatment of the carotid stenosis. In 23 aneurysms associated with bilateral pICA stenosis, there was only one case that increased in size during a 41-month period. Intracranial aneurysms were most likely associated with ECAD, but were evenly distributed irrespective of the laterality of the stenosis. The distribution was related to the severity of the contralateral pICA stenosis. The low incidence of aneurysm growth or rupture in patients with significant ECAD indicates that these aneurysms do not require immediate intervention more than other conditions. Copyright © 2013 Elsevier B.V. All rights reserved.
Kilic, Salih; Kocabas, Umut; Can, Levent Hurkan; Yavuzgil, Oguz; Zoghi, Mehdi
2018-01-01
Background It is widely believed that ST-elevated myocardial infarction (STEMI) generally occurs at the site of mild to moderate coronary stenosis. The aim of this study was to determine the degree of stenosis of infarct-related artery (IRA) in STEMI patients who underwent coronary angiography (CAG) after successful reperfusion with thrombolytic therapy (TT). Methods A total of 463 consecutive patients between January 2008 and December 2013 with acute STEMI treated with TT were evaluated retrospectively. The patients in whom reperfusion failed (n = 120), death occurred before CAG (n = 12), IRA cannot be determined (n = 10), and CAG was not performed in index hospitalization (n = 54) were excluded from the study. To determine the severity of stenosis of IRA, two experienced cardiologists who were unaware of each other used quantitative CAG analysis. Significant stenosis was defined as a ≥ 50% stenosis in the coronary artery lumen. A total of 267 patients who were successfully reperfused with TT and in whom CAG was performed during hospitalization with median 8 (1 - 17) days after myocardial infarction were included in the study. Results The mean age of patients was 55.7 ± 10.8 years (85.5% male). Most of the patients had a significant stenosis in IRA ( ≥ 50%, n = 236, group 1) after successful TT; whereas only 11.6% had stenosis < 50% (n = 31, group 2). In addition, majority of the patients had ≥ 70.4% (n = 188, 70.4%) stenosis in IRA. Average of stenosis in IRA was 74±16%. Conclusions In contrast to the general opinion, we detected that majority of STEMI patients had a significant stenosis in IRA. PMID:29479380
Alders, David J C; Groeneveld, A B Johan; Binsl, Thomas W; van Beek, Johannes H G M
2015-11-15
In normal hearts, myocardial perfusion is fairly well matched to regional metabolic demand, although both are distributed heterogeneously. Nonuniform regional metabolic vulnerability during coronary stenosis would help to explain nonuniform necrosis during myocardial infarction. In the present study, we investigated whether metabolism-perfusion correlation diminishes during coronary stenosis, indicating increasing mismatch of regional oxygen supply to demand. Thirty anesthetized male pigs were studied: controls without coronary stenosis (n = 11); group I, left anterior descending (LAD) coronary stenosis leading to coronary perfusion pressure reduction to 70 mmHg (n = 6); group II, stenosis with perfusion pressure of about 35 mmHg (n = 6); and group III, stenosis with perfusion pressure of 45 mmHg combined with adenosine infusion (n = 7). [2-(13)C]- and [1,2-(13)C]acetate infusion was used to calculate regional O2 consumption from glutamate NMR spectra measured for multiple tissue samples of about 100 mg dry mass in the LAD region. Blood flow was measured with microspheres in the same regions. In control hearts without stenosis, regional oxygen extraction did not correlate with basal blood flow. Average myocardial O2 delivery and consumption decreased during coronary stenosis, but vasodilation with adenosine counteracted this. Regional oxygen extraction was on average decreased during stenosis, suggesting adaptation of metabolism to lower oxygen supply after half an hour of ischemia. Whereas regional O2 delivery correlated with O2 consumption in controls, this relation was progressively lost with graded coronary hypotension but partially reestablished by adenosine infusion. Therefore, coronary stenosis leads to heterogeneous metabolic stress indicated by decreasing regional O2 supply to demand matching in myocardium during partial coronary obstruction. Copyright © 2015 the American Physiological Society.
Ikai, Akio; Shirai, Mikiyasu; Nishimura, Kazunobu; Ikeda, Tadashi; Kameyama, Takayuki; Ueyama, Koji; Komeda, Masashi
2005-01-01
After cavopulmonary shunt in which the superior vena cava is anastomosed to the right pulmonary artery, the right lung is in a unique condition without flow pulsatility and hepatic venous effluent. In a previous study, we reported that hypoxic pulmonary vasoconstriction disappeared in the pulmonary circulation after cavopulmonary shunt. In this study, however, to investigate the influence of pulsatility and hepatic venous effluent on hypoxic pulmonary vasoconstriction in the pulmonary circulation, we developed an alternative cavopulmonary shunt rabbit model that included hepatic venous effluent in the pulmonary circulation and reduced the pulsatility of the pulmonary arterial blood flow. We then observed the physiologic characteristics of the peripheral pulmonary artery after cavopulmonary shunt, specifically the disappearance of hypoxic pulmonary vasoconstriction. Sixteen Japanese white rabbits (12-16 weeks old) were used in this study. With general anesthesia, a cavopulmonary shunt was established by anastomosing the right superior vena cava to the right pulmonary artery in an end-to-side fashion. Of the 16 rabbits for the study, the proximal right pulmonary artery was completely ligated in 5 (atresia group) and partially ligated in 6 (stenosis group). Sham operation was performed in the remaining 5 rabbits. Two weeks later, we analyzed the response of the pulmonary artery (which was divided into three categories: segmental, lobular, and acinar level artery) to hypoxia (8% oxygen inhalation) with a specially designed video radiographic system. Morphometric analysis of the resistance pulmonary artery was done in each group after angiography. Mean pressure and pulse pressure in the right pulmonary artery were not significantly different between the atresia and stenosis groups. The mean pulmonary artery pressures in the atresia and stenosis groups were 8 and 11 mm Hg, respectively. However, the pulse pressure was less than 2 mm Hg in both groups. The baseline internal diameter of the resistance pulmonary artery of the atresia group was significantly different from those of the stenosis and sham groups. In the atresia group, the resistance pulmonary arteries did not respond to hypoxia. In contrast, significant constriction (as assessed by percentage change of internal diameter of the resistance pulmonary arteries in the acinar and lobular level arteries) was observed in the pulmonary arteries of the sham and stenosis groups (atresia vs stenosis vs sham 0.4% vs - 19.0% vs - 18.8%, P = .01). In our morphometric study, we observed vasodilation of the resistance pulmonary artery with a thinner medial layer in the atresia group, consistent with the result of microangiography. We developed a cavopulmonary shunt rabbit model in which the inferior vena caval blood was derived from the right ventricle. Hypoxic pulmonary vasoconstriction was maintained in the model with the blood flow from the right ventricle. When the blood flow was not maintained, however, hypoxic pulmonary vasoconstriction disappeared. This phenomenon strongly suggests that a substance in hepatic venous effluent partially regulates the physiological pulmonary vascular function in the rabbit lung.
NASA Astrophysics Data System (ADS)
Castro, Marcelo A.; Peloc, Nora L.; Chien, Aichi; Goldberg, Ezequiel; Putman, Christopher M.; Cebral, Juan R.
2015-03-01
Cerebral aneurysms may rarely coexist with a proximal artery stenosis. In that small percent of patients, such coexistence poses a challenge for interventional neuroradiologists and neurosurgeons to make the best treatment decision. According to previous studies, the incidence of cerebral aneurysms in patients with internal carotid artery stenosis is no greater than five percent, where the aneurysm is usually incidentally detected, being about two percent for aneurysms and stenoses in the same cerebral circulation. Those cases pose a difficult management decision for the physician. Case reports showed patients who died due to aneurysm rupture months after endarterectomy but before aneurysm clipping, while others did not show any change in the aneurysm after plaque removal, having optimum outcome after aneurysm coiling. The aim of this study is to investigate the intra-aneurysmal hemodynamic changes before and after treatment of stenotic plaque. Virtually created moderate stenoses in vascular models of internal carotid artery aneurysm patients were considered in a number of cases reconstructed from three dimensional rotational angiography images. The strategy to create those plaques was based on parameters analyzed in a previous work where idealized models were considered, including relative distance and stenosis grade. Ipsilateral and contralateral plaques were modeled. Wall shear stress and velocity pattern were computed from finite element pulsatile blood flow simulations. The results may suggest that wall shear stress changes depend on relative angular position between the aneurysm and the plaque.
Obstruction after Self-expanding Metallic Stents in Tuberculous Bronchial Stenosis
Kim, Won; Lee, Youg Chul; Rhee, Yang Keun
1995-01-01
Expandable metallic stents seemed to be a good method in tuberculous bronchial stenosis that does not respond to medical therapy. But there was no long-term follow-up study after stents insertion in tuberculous bronchial stenosis. We report a case of obstruction after successful Gianturco metallic stents insertion due to tuberculous bronchial stenosis. PMID:7542914
C-reactive protein in degenerative aortic valve stenosis
Sanchez, Pedro L; Mazzone, AnnaMaria
2006-01-01
Degenerative aortic valve stenosis includes a range of disorder severity from mild leaflet thickening without valve obstruction, "aortic sclerosis", to severe calcified aortic stenosis. It is a slowly progressive active process of valve modification similar to atherosclerosis for cardiovascular risk factors, lipoprotein deposition, chronic inflammation, and calcification. Systemic signs of inflammation, as wall and serum C-reactive protein, similar to those found in atherosclerosis, are present in patients with degenerative aortic valve stenosis and may be expression of a common disease, useful in monitoring of stenosis progression. PMID:16774687
Harper, Yenal; Salem, Salem A; Alsafwah, Shadwan; Koshy, Santhosh; Garg, Nadish
2018-01-01
Mitral stenosis is a uncommon valvular lesion in the developed countries. Noninvasive evaluation is the first-line modality for assessment of mitral stenosis, however the noninvasive methods may have limitations in certain cases. Invasive hemodynamics can be used as adjunct tool for assessment of mitral stenosis in such difficult cases. Mitral valve using three-dimensional planimetry is a promising technique for assessment of mitral stenosis. © 2018 Wiley Periodicals, Inc.
Initial in vitro and in vivo evaluation of a self-monitoring prosthetic bypass graft.
Neville, Richard F; Gupta, Samit K; Kuraguntla, David J
2017-06-01
Prosthetic grafts used for lower extremity revascularization and dialysis access fail because of hyperplastic stenosis and thrombosis. Graft surveillance is advocated to monitor function; however, graft failure can occur between episodic examinations. An innovative sensor with wireless, microchip technology allows automated surveillance with assessment of graft function using a "cloud"-based algorithm. We performed proof-of-concept experiments with in vitro and in vivo models to assess the feasibility such a real-time graft surveillance system. A self-monitoring graft system was evaluated consisting of a prosthetic conduit of expanded polytetrafluoroethylene and a sensor unit, and a microsensor, microelectronics, battery, and remote processor with a monitor. The sensor unit was integrated on the extraluminal surface of expanded polytetrafluoroethylene grafts without compromise to the lumen of the conduit. The grafts were tested in vitro in a pulsatile, recirculating flow system under physiologic flow parameters. The hemodynamic parameters were varied to assess the ability to obtain wireless signal acquisition reflecting real-time flow properties in vitro. Segments of custom tubing with reduced diameters were inserted into the model to mimic stenosis proximal and distal to the grafts. After characterization of the initial data, the self-monitoring grafts were implanted in an ovine carotid model to assess proof of concept in vivo with 30-day follow-up of signal acquisition as well as arteriographic and histologic analysis. In vitro flow data demonstrated the device was able to determine factors related to prosthetic graft function under varied hemodynamic flow conditions. Wireless signal acquisition using Bluetooth technology (Bluetooth SIG, Inc, Kirkland, Wash) allowed remote data analysis reflecting graft flow parameters through changes in microsensor voltage and frequency. Waveform analysis was applied to construct an algorithm using proprietary software and determine a parameter for graft flow characteristics. This algorithm allowed determination of the degree of stenosis and location of stenosis location (proximal or distal) for display on a remote monitor in real time. Subsequent in vivo experiments confirmed the ability of the system to generate signal acquisition through skin and soft tissue under biologic conditions with no arteriographic stenosis and a favorable healing response at 30-day harvest. Initial in vitro and in vivo experiments demonstrate the ability for a self-monitoring graft system to remotely monitor hemodynamic parameters reflecting graft function using wireless data transmission. This automated system shows promise to deliver real-time data that can be analyzed by cloud-based algorithms alerting the clinician of a change in graft function or development of stenosis for further diagnostic study or intervention before graft failure. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Seaman, Clara; Akingba, A George; Sucosky, Philippe
2014-04-01
The bicuspid aortic valve (BAV), which forms with two leaflets instead of three as in the normal tricuspid aortic valve (TAV), is associated with a spectrum of secondary valvulopathies and aortopathies potentially triggered by hemodynamic abnormalities. While studies have demonstrated an intrinsic degree of stenosis and the existence of a skewed orifice jet in the BAV, the impact of those abnormalities on BAV hemodynamic performance and energy loss has not been examined. This steady-flow study presents the comparative in vitro assessment of the flow field and energy loss in a TAV and type-I BAV under normal and simulated calcified states. Particle-image velocimetry (PIV) measurements were performed to quantify velocity, vorticity, viscous, and Reynolds shear stress fields in normal and simulated calcified porcine TAV and BAV models at six flow rates spanning the systolic phase. The BAV model was created by suturing the two coronary leaflets of a porcine TAV. Calcification was simulated via deposition of glue beads in the base of the leaflets. Valvular performance was characterized in terms of geometric orifice area (GOA), pressure drop, effective orifice area (EOA), energy loss (EL), and energy loss index (ELI). The BAV generated an elliptical orifice and a jet skewed toward the noncoronary leaflet. In contrast, the TAV featured a circular orifice and a jet aligned along the valve long axis. While the BAV exhibited an intrinsic degree of stenosis (18% increase in maximum jet velocity and 7% decrease in EOA relative to the TAV at the maximum flow rate), it generated only a 3% increase in EL and its average ELI (2.10 cm2/m2) remained above the clinical threshold characterizing severe aortic stenosis. The presence of simulated calcific lesions normalized the alignment of the BAV jet and resulted in the loss of jet axisymmetry in the TAV. It also amplified the degree of stenosis in the TAV and BAV, as indicated by the 342% and 404% increase in EL, 70% and 51% reduction in ELI and 48% and 51% decrease in EOA, respectively, relative to the nontreated valve models at the maximum flow rate. This study indicates the ability of the BAV to function as a TAV despite its intrinsic degree of stenosis and suggests the weak dependence of pressure drop on orifice area in calcified valves.
Computational modeling of venous sinus stenosis in idiopathic intracranial hypertension
Levitt, Michael R; McGah, Patrick M; Moon, Karam; Albuquerque, Felipe C; McDougall, Cameron G; Kalani, M Yashar S; Kim, Louis J; Aliseda, Alberto
2016-01-01
Background and Purpose Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model using patient-specific blood pressure measurements. Materials and Methods Six patients with idiopathic intracranial hypertension and at least one stenosis or atresia at the transverse-sigmoid sinus junction underwent MRV followed by cerebral venography and manometry throughout the dural venous sinuses. Patient-specific computational fluid dynamics models were created using MRV anatomy, with venous pressure measurements as boundary conditions. Blood flow and wall shear stress were calculated for each patient. Results Computational models of dural venous sinuses were successfully reconstructed in all six patients with patient-specific boundary conditions. Three patients demonstrated a pathologic pressure gradient (≥ 8 mm Hg) across four dural venous sinus stenoses. Small sample size precludes statistical comparisons, but average overall flow throughout the dural venous sinuses of patients with pathologic pressure gradients was higher than in those without (1041.00 ± 506.52 vs. 358.00 ± 190.95 mL/min). Wall shear stress was also higher across stenoses in patients with pathologic pressure gradients (37.66 ± 48.39 vs 7.02 ± 13.60 Pa). Conclusion The hemodynamic environment of the dural venous sinuses can be computationally modeled using patient-specific anatomy and physiological measurements in patients with idiopathic intracranial hypertension. There was substantially higher blood flow and wall shear stress in patients with pathological pressure gradients. PMID:27197986
Carotid recurrent stenosis and risk of ipsilateral stroke: a systematic review of the literature.
Frericks, H; Kievit, J; van Baalen, J M; van Bockel, J H
1998-01-01
The main goal of follow-up after carotid endarterectomy is to prevent new strokes caused by recurrent stenosis. To determine the most cost-effective follow-up schedule, it is necessary to know the incidence of recurrent stenosis and the risk of stroke it carries. A systematic review of the literature was performed using standard meta-analytical techniques. Incidence of recurrent stenosis: The data were very heterogeneous. The risk of recurrent stenosis was 10% in the first year, 3% in the second, and 2% in the third. Long-term risk of recurrent stenosis is about 1% per year. Risk of stroke: The reported relative risks of stroke in patients with recurrent stenosis compared with patients without recurrent stenosis showed extreme heterogeneity and ranged from 10 to 0.10. The random effects summary estimator of relative risk was 1.88. The data were very heterogeneous, and much better data are needed to arrive at truly reliable estimates of these important parameters of follow-up. It is clear, though, that the risk of recurrent stenosis is highest in the first few years after carotid endarterectomy and very low in later years. By use of general decision-analytic arguments, it can be argued that, given the test characteristics of carotid ultrasound, a small number of tests can be done in the first few years and that testing for restenosis should not be done after 4 years.
[Feasibility of sonography in the diagnosis of congenital heart diseases in dogs].
Schneider, M; Schneider, I; Neu, H
1998-05-01
In ultrasound examination of the heart it is useful to combine the following techniques: echocardiography (in 2D and M-mode) gives information about morphology and motion of the heart. By using Doppler echocardiography (black and white or preferably colour) it is possible to evaluate bloodstreams and with contrast echocardiography shunts in the heart can be demonstrated. In our study (1994-1996) the following congenital heart defects were the most common in dogs: subaortic stenosis (SAS, 41%), pulmonic stenosis (PS, 19%), patent ductus arteriosus (PDA, 11%) and the combination of subaortic stenosis with pulmonic stenosis (11%). Echocardiography allows the morphologic evaluation of the primary defect in detail, for example the differentiation between aortic valve stenosis and subaortic stenosis. However the exact identification of the patent ductus arterious and of the morphology in pulmonic stenosis can remain difficult, especially in patients showing dyspnoe. In heart sonography quantitative measurements are available to graduate the defects, but guidelines for these measurements are not yet defined. The demonstration of secondary and combined defects, which are important for therapy is easily possible with heart ultrasound examination. Secondary insufficiencies are often seen at the mitral valve because of primary subaortic stenosis or patent ductus arteriosus and at the tricuspid valve because of pulmonic stenosis. For differentiation of combined heart defects (SAS with PS; SAS with PDA; PS with atrium septum defect) heart ultrasound is extremely valuable.
Radiology-guided forceps biopsy and airway stenting in severe airway stenosis
Li, Zong-Ming; Wu, Gang; Han, Xin-Wei; Ren, Ke-Wei; Zhu, Ming
2014-01-01
PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. RESULTS The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. CONCLUSION Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy. PMID:24808434
Tsukioka, Takuma; Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Tei, Keiko; Yamamoto, Ryoji
2015-07-01
Surgical reconstruction is commonly recommended for the treatment of tuberculous airway stenosis. The clinical conditions underlying tuberculous airway stenosis often involve both cicatricial stenosis and malacia. Surgical reconstruction alone may not improve the respiratory symptoms of patients with both types of airway stenosis. This study retrospectively reviewed patients who underwent surgical reconstruction for tuberculous airway stenosis to investigate the most appropriate treatment for this complicated condition. Twelve patients with tuberculous airway stenosis underwent surgical reconstruction at our institute from January 2003 to December 2013. The clinical courses of these patients were retrospectively reviewed. The 12 patients were 2 men and 10 women with a mean age of 36 years (range 17-61 years). The site of stenosis was the left main bronchus in six patients, trachea in four patients, and right main bronchus in two patients. The procedure performed was sleeve lobectomy in five patients, bronchial resection in four patients, and tracheal resection in three patients. Additional airway stenting was performed in two patients with concomitant malacia of the lower trachea. The performance status and Hugh-Jones classification improved postoperatively in all patients. The forced expiratory volume in 1 s as a percent of forced vital capacity and percent of forced expiratory volume in 1 s improved significantly. Surgical reconstruction is an acceptable treatment for tuberculous airway stenosis. Additional airway stenting may be needed in patients with symptomatic malacia.
Congenital mitral stenosis, subvalvular aortic stenosis, and congestive heart failure in a duck.
Mitchell, Elizabeth B; Hawkins, Michelle G; Orvalho, Joao S; Thomas, William P
2008-06-01
A 2.6-year-old duck was evaluated for respiratory difficulty. On the basis of physical, radiographic and echocardiographic findings, a diagnosis of congestive heart failure secondary to congenital mitral stenosis and subvalvular aortic stenosis was made. The duck did not respond well to medical therapy and was euthanized. The diagnosis was confirmed at necropsy.
FAMM Flap in Reconstructing Postsurgical Nasopharyngeal Airway Stenosis
Nangole, Ferdinand Wanjala; Khainga, Stanley Ominde
2014-01-01
Introduction. Postsurgical nasopharyngeal airway stenosis can be a challenge to manage. The stenosis could be as a result of any surgical procedure in the nasopharyngeal region that heals extensive scarring and fibrosis. Objective. To evaluate patients with nasopharyngeal stenosis managed with FAMM flap. Study Design. Prospective study of patients with nasopharyngeal stenosis at the Kenyatta National Hospital between 2010 and 2013 managed with FAMM flap. Materials and Methods. Patients with severe nasopharyngeal airway stenosis were reviewed and managed with FAMM flaps at the Kenyatta National Hospital. Postoperatively they were assessed for symptomatic improvement in respiratory distress, patency of the nasopharyngeal airway, and donor site morbidity. Results. A total of 8 patients were managed by the authors in a duration of 4 years with nasopharyngeal stenosis. Five patients were managed with unilateral FAMM flaps in a two-staged surgical procedure. Four patients had complete relieve of the airway obstruction with a patent airway created. One patient had a patent airway created though with only mild improvement in airway obstruction. Conclusion. FAMM flap provides an alternative in the management of postsurgical severe nasopharyngeal stenosis. It is a reliable flap that is easy to raise and could provide adequate epithelium for the stenosed pharynx. PMID:25328699
Spinal stenosis presenting as "the postpolio syndrome". Review of four cases.
LaBan, M M; Sanitate, S S; Taylor, R S
1993-12-01
The diagnosis of postpolio syndrome is based primarily on a thorough history supported by both clinical and laboratory examination. Similarly, the presence of an occult spinal stenosis may be suspected initially by a history of progressive lumbar or cervical radicular pain, as well as concomitant extremity weakness and/or myelopathic signs. Appropriate electrodiagnostic examinations, including somatosensory spinal-evoked potentials and electroneuromyography, as well as imaging studies, computer-assisted tomography scan, magnetic resonance imaging and/or myelography are all useful in confirming the clinical diagnosis of either cervical spinal stenosis or lumbar spinal stenosis in patients who also may have had a history of poliomyelitis. Four patients (three men and one woman) previously diagnosed as having postpolio syndrome were referred with predominate complaints of spinal and extremity pain as well as associated motor weakness. It was subsequently recognized that these patients, ranging in age from 45-65 yr, were actually presenting with symptomatic spinal stenosis. It was discovered that two patients had cervical spinal stenosis; the other two had lumbar spinal stenosis.
... Overview Spinal stenosis is a narrowing of the spaces within your spine, which can put pressure on ... stenosis, doctors may recommend surgery to create additional space for the spinal cord or nerves. Types of ...
Double stenting with silicone and metallic stents for malignant airway stenosis.
Matsumoto, Keitaro; Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi
2017-08-01
For severe malignant airway stenosis, there are several types of commercially available airway stents, and each has its own advantages and disadvantages. We herein describe the safety and efficacy of combination stenting with silicone and metallic stents for patients with extended malignant airway stenosis. Seven patients with malignant airway stenosis were treated via combination stenting with a silicone stent and a metallic stent for extended airway stenosis from the central to peripheral airways. Five patients were diagnosed with advanced esophageal cancer, two of whom had tracheoesophageal fistulas. One patient had adenoid cystic carcinoma, and another had mediastinal tumor. There were no specific complications related to the double stenting. Combination stenting with silicone and metallic stents proved to be a safe option for patients with severe, extended, and complicated malignant airway stenosis.
External auditory canal stenosis due to the use of powdered boric acid.
Dündar, Riza; Soy, Fatih Kemal; Kulduk, Erkan; Muluk, Nuray Bayar; Cingi, Cemal
2014-09-01
Acquired stenosis of the external auditory canal (EAC) may occur because of chronic external otitis, recurrent chronic catarrhal otitis media associated with tympanic membrane perforation, chronic dermatitis, tumors, and trauma. Stenosis occurs generally at the one-third bone part of the external auditory canal. In this article, we present 3 cases of acquired EAC stenosis due to the previous powdered boric acid application. Besides the presentation of surgical intervetions in these cases, we want to notify the physicians not to use or carefully use powdered boric acid because of the complication of EAC stenosis.
Percutaneous tricuspid valvotomy for pacemaker lead-induced tricuspid stenosis
Patil, Devendra V.; Nabar, Ashish A.; Sabnis, Girish R.; Phadke, Milind S.; Lanjewar, Charan P.; Kerkar, Prafulla G.
2015-01-01
Permanent pacemaker lead-induced tricuspid regurgitation is extremely uncommon. We report a patient with severe tricuspid stenosis detected 10 years after permanent single chamber pacemaker implantation in surgically corrected congenital heart disease. The loop at the level of the tricuspid valve may have caused endothelial injury and eventually led to stenosis. Percutaneous balloon valvotomy for such stenosis has not been reported from India. PMID:26995417
2015-06-04
control, vibration and noise control, health monitoring, and energy harvesting . However, these advantages come at the cost of rate-dependent hysteresis...configuration used for energy harvesting . Uncertainty Quantification Uncertainty quantification is pursued in two steps: (i) determination of densities...Crews and R.C. Smith, “Quantification of parameter and model uncertainty for shape mem- ory alloy bending actuators,” Journal of Intelligent material
Sultan, Sherif; Kavanagh, Edel P; Hynes, Niamh; Diethrich, Edward B
2016-02-01
This study outlines the use of non-aneurysmal porcine animal models to study device functionality and biological response of the Multilayer Flow Modulator (MFM) (Cardiatis, Isnes, Belgium), with an emphasis on preclinical device functionality and biological response characteristics in an otherwise healthy aorta. Twelve animals were implanted with the study device in the abdominal aorta, in 6 animals for 1 month and 6 animals for 6 months. Upon completion of the study period, each animal underwent a necropsy to examine how the implanted device had affected the artery and surrounding tissue. Neointima and stenosis formation were recorded via morphometry, and endothelialization via histopathological analysis. The MFM devices were delivered to their respective implantation sites without difficulty. Six of the implanted stents were oversized with percentages ranging from 2.6% to 18.8%. Statistical analysis was carried out and showed no significance between the regular sized stent group and oversized stent group for neointimal area (P=0.17), neointimal thickness (P=0.17), and percentage area stenosis (P=0.65). Histopathological findings showed in most areas flattened endothelium like cells lined the luminal surface of the neointima. Scanning electron microscopy also showed the devices were well tolerated, inciting only a minimal neointimal covering and little fibrin or platelet deposition. Neointimal thickness of 239.7±55.6 μm and 318.3±130.4 μm, and percentage area stenosis of 9.6±2.6% and 12.6±5% were recorded at 1 and 6 months respectively. No statistical differences were found between these results. The MFM devices were delivered to their respective implantation sites without difficulty and incited little neointimal and stenosis formation in the aorta, affirming its functionality and biocompatibility.
Bonati, Leo H; Ederle, Jörg; Dobson, Joanna; Engelter, Stefan; Featherstone, Roland L; Gaines, Peter A; Beard, Jonathan D; Venables, Graham S; Markus, Hugh S; Clifton, Andrew; Sandercock, Peter; Brown, Martin M
2014-04-01
The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials. In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface. Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.
Duan, Jian Gang; Chen, Xiang Yan; Lau, Alex; Wong, Adrian; Thomas, G. Neil; Tomlinson, Brian; Liu, Roxanna; Chan, Juliana C. N.; Leung, Thomas W.; Mok, Vincent; Wong, Ka Sing
2014-01-01
Objective To investigate whether asymptomatic middle cerebral artery (MCA) stenosis is associated with risk of cardiovascular disease (CVD) in Chinese with type 2 diabetes. Methods In this prospective cohort study, 2,144 Hong Kong Chinese with type 2 diabetes and without history of stroke or atrial fibrillation were recruited in 1994–1996 and followed up for a median of 14.51 years. Participants were assessed at baseline for MCA stenosis using transcranial Doppler. We performed survival analysis to assess the association between asymptomatic MCA stenosis and first CVD event, defined as ischemic stroke, acute coronary syndrome (ACS) or cardiovascular death. Results Of the 2,144 subjects, MCA stenosis at baseline was detected in 264 (12.3%). Rates of stroke, ACS and cardiovascular death per 100 were, respectively, 2.24, 2.92 and 1.11 among participants with stenosis, higher than among those without stenosis. Ten-year cumulative occurrence of stroke, ACS and cardiovascular death in subjects with MCA stenosis was 20%, 24% and 10%, respectively, higher than the corresponding values for subjects without stenosis(all P<0.001). After adjusting for covariates, MCA stenosis was found to be an independent predictor of stroke [hazard ratio (HR) 1.40, 95%CI 1.05–1.86; P = 0.02], ACS (HR 1.35, 95%CI 1.04–1.75; P = 0.02) and cardiovascular death(HR 1.56, 95%CI 1.04–2.33; P = 0.03). Conclusions Asymptomatic MCA stenosis is a risk factor for CVD in Chinese with type 2 diabetes, and detection of asymptomatic MCA stenosis by transcranial Doppler can identify diabetic individuals at high risk of future CVD. This finding is particularly important for diabetic individuals in Asia, where intracranial atherosclerosis is common. PMID:25192283
Parker, Noah P.; Bandyopadhyay, Dipankar; Misono, Stephanie; Goding, George S.
2017-01-01
Objectives/Hypothesis To describe the presentation, stenosis characteristics, etiological differences, and outcomes of adult laryngotracheal stenosis treated with endoscopic cold incision, balloon dilation, topical mitomycin C application, and steroid injection. Study Design Retrospective chart review. Methods Demographic and clinical data were extracted for patients treated between March 2000 and December 2010. Prolonged intubation and idiopathic patient data were utilized for comparative analysis. Results Eighty patients (65 females; 15 males; 220 procedures; 2.9 years mean follow-up) presented with dyspnea (81%) and/or exercise intolerance (40%). Most commonly, etiologies were idiopathic (53 of 80; 66%) or prolonged intubation (14 of 80; 18%). Mean procedures per patient and interval between procedures were 2.8 procedures and 405 days, respectively. Mean stenosis length and distance from the caudal phonating edge of the true vocal folds were 9 mm and 19 mm. Complication, tracheotomy, and open-procedure rates were 1.8%, 1.4%, and 10.0%, respectively. Patients with more than two procedures demonstrated a mean 4-mm reduction in stenosis length and a 2-mm cephalad progression of stenosis over time. More caudal stenoses required more frequent procedures. Procedures were less frequent as more procedures were performed. Stenosis characteristics, interval between procedures, and total procedures were similar between idiopathic patients with or without intubation histories, but different between idiopathic and prolonged intubation patients. Conclusions This procedure was shown to be a viable option in adult laryngotracheal stenosis. Repeat dilation was likely, but was performed without adversely affecting stenosis characteristics. Stenoses farther from the vocal folds required procedures more frequently. Idiopathic patients with a history of brief, elective intubation had stenosis characteristics and responses to therapy similar to idiopathic patients without an intubation history. Both idiopathic groups together demonstrated stenosis characteristics and responses to therapy dissimilar to patients with a history of prolonged intubation. PMID:23086662
Mitral stenosis is a heart valve disorder that narrows or obstructs the mitral valve opening. Narrowing of the ... to the body. The main risk factor for mitral stenosis is a history of rheumatic fever but it ...
Saleem, Ayesha; Ali, Azmat
2017-02-01
To determine the correlation of C-reactive protein (CRP) levels with the severity of coronary stenosis on angiography and the association of cardiac enzymes with the degree of stenosis in acute coronary syndrome (ACS) patients. Secondly, to compare association of angiographic severity of vascular stenosis with CRP in patients with ST segment elevation myocardial infarction (STEMI) and non-STEMI / Unstable angina (UA). Prospective, descriptive study. Khan Research Laboratories (KRL) Hospital, from October 2014 to March 2015. CRP was measured on diagnosis of ACS in 70 patients. Cardiac enzymes were measured 6 hours after the onset of chest pain. Angiographic scoring for degree of stenosis and number of culprit vessels was done. Two groups consisting of patients with STEMI (group 1) and with NSTEMI/UA (group 2) were made. No correlation was found between CRP levels and angiographic stenosis in patients with ACS (r=0.162, p>0.05). No association was found between eosinophil count and severity of stenosis (p=0.88). Rise of cardiac enzymes and degree of coronary stenosis showed a positive correlation (p <0.001). There was significant difference in the means of coronary artery stenosis scores between the two groups (Gensini score of groups 1 and 2: 35.9 ±4 and 14 ±8, respectively) p<0.001, but there was no significant difference in CRP levels. CRP is a marker of inflammation in ACS rather than a risk factor for determining the severity of vascular stenosis. Rise in cardiac enzymes still grade high in predicting severity of vascular stenosis than eosinophil count or CRP levels.
Simplified ultrasound protocol for the exclusion of clinically significant carotid artery stenosis.
Högberg, Dominika; Dellagrammaticas, Demosthenes; Kragsterman, Björn; Björck, Martin; Wanhainen, Anders
2016-08-01
To evaluate a simplified ultrasound protocol for the exclusion of clinically significant carotid artery stenosis for screening purposes. A total of 9,493 carotid arteries in 4,748 persons underwent carotid ultrasound examination. Most subjects were 65-year-old men attending screening for abdominal aortic aneurysm. The presence of a stenosis on B-mode and/or a mosaic pattern in post-stenotic areas on colour Doppler and maximum peak systolic velocity (PSV) in the internal carotid artery (ICA) were recorded. A carotid stenosis was defined as The North American Symptomatic Carotid Endarterectomy Trial (NASCET) >20% and a significant stenosis as NASCET >50%. The kappa (κ) statistic was used to assess agreement between methods. Sensitivity, specificity, positive predictive (PPV), and negative predictive (NPV) values were calculated for the greyscale/mosaic method compared to conventional assessment by means of PSV measurement. An ICA stenosis was found in 121 (1.3%) arteries; 82 (0.9%) were graded 20%-49%, 16 (0.2%) were 50%-69%, and 23 (0.2%) were 70%-99%. Eighteen (0.2%) arteries were occluded. Overall, the greyscale/mosaic protocol showed a moderate agreement with ICA PSV measurements for the detection of carotid artery stenosis, κ = 0.455. The sensitivity, specificity, PPV, and NPV for detection of >20% ICA stenosis were 91% (95% CI 0.84-0.95), 97% (0.97-0.98), 31% (0.26-0.36), and 97% (0.97-0.97), respectively. The corresponding figures for >50% stenosis were 90% (0.83-0.95), 97% (0.97-0.98), 11% (0.08-0.15), and 100% (0.99-1.00). Compared with PSV measurements, the simplified greyscale/mosaic protocol had a high negative predictive value for detection of >50% carotid stenosis, suggesting that it may be suitable as a screening method to exclude significant disease.
Noh, Sang-Mi; Choi, Won Jun; Kang, Byeong-Teck; Jeong, Sang-Wuk; Lee, Dong Kun; Schellingerhout, Dawid; Yeo, Jeong-Seok
2013-01-01
Background and Purpose To estimate clinical roles of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) versus angiography and ultrasonography in carotid plaque characterization. Methods We characterized two groups of patients with recently (<1 month) symptomatic (n=14; age=71.8±8.6 years, mean±SD) or chronic (n=13, age=68.9±9.0 years) carotid stenosis using a battery of imaging tests: diffusion magnetic resonance (MR) imaging, MR or transfemoral angiography, duplex ultrasonography (DUS), and carotid FDG-PET/computed tomography. Results The degree of angiographic stenosis was greater in patients with recently symptomatic carotid plaques (67.5±21.5%) than in patients with chronic carotid plaques (32.4±26.8%, p=0.001). Despite the significant difference in the degree of stenosis, lesional maximum standardized uptake values (maxSUVs) on the carotid FDG-PET did not differ between the recently symptomatic (1.56±0.53) and chronic (1.56±0.34, p=0.65) stenosis groups. However, lesional-to-contralesional maxSUV ratios were higher in the recently symptomatic stenosis group (113±17%) than in the chronic stenosis group (98±10%, p=0.017). The grayscale median value of the lesional DUS echodensities was lower in the recently symptomatic stenosis group (28.2±10.0, n=9) than in the chronic stenosis group (53.9±14.0, n=8; p=0.001). Overall, there were no significant correlations between angiographic stenosis, DUS echodensity, and FDG-PET maxSUV. Case/subgroup analyses suggested complementarity between imaging modalities. Conclusions There were both correspondences and discrepancies between the carotid FDG-PET images and DUS or angiography data. Further studies are required to determine whether FDG-PET could improve the clinical management of carotid stenosis. PMID:23894241
Ahmed, Rehan; Kazmi, Nasir; Naz, Farhat; Malik, Saqib; Gillani, Saima
2016-01-01
Rheumatic heart disease is a common ailment in Pakistan and Mitral stenosis is its flag bearer Severity of mitral stenosis is the key factor in deciding for mitral valve surgery. This case series study was conducted at Ayub Teaching Hospital .Cases of Rheumatic heart disease with mitral stenosis were diagnosed clinically. 2D echocardiography was used to find severity of mitral stenosis. Data was entered into SPSS-17.0 and results were recorded and analysed. Pearson's two tailed correlation was used to find the correlation between presence of tricuspid regurgitation in patients with severe mitral stenosis, p was <0.05. A total 35 patients with pure mitral stenosis were included in study, out of which 8 were male and 27 were females. Mean age in males was 34.5±15.85 years while in females it was 31±8 years. Twenty-two out of 35 (62.86%) patients had tricuspid regurgitation while 13 out 35 (37.14%) had no tricuspid regurgitation. Mean (MVA) mitral valve area in patients with tricuspid regurgitation was 0.84±0.3 cm2 while mean (MVA) mitral valve area in patients without tricuspid regurgitation was 1.83±0.7 cm2. Mean left atrial (L.A) size was 45.23±1.5 mm2 in patients with tricuspid regurgitation, while it was 44.13±6.14 mm2 in patients without tricuspid regurgitation. Mean RSVP was 57.5mmHg in patients with tricuspid regurgitation while RSVP could not be calculated in patients without tricuspid regurgitation. It was concluded that tricuspid regurgitation was strongly associated with severe mitral stenosis as almost all patients with severe mitral stenosis had tricuspid regurgitation and none of the patients with mild mitral stenosis had tricuspid regurgitation.
Phenotyping of lumbosacral stenosis in Labrador retrievers using computed tomography.
Mukherjee, Meenakshi; Jones, Jeryl C; Holásková, Ida; Raylman, Raymond; Meade, Jean
2017-09-01
Deep phenotyping tools for characterizing preclinical morphological conditions are important for supporting genetic research studies. Objectives of this retrospective, cross-sectional, methods comparison study were to describe and compare qualitative and quantitative deep phenotypic characteristics of lumbosacral stenosis in Labrador retrievers using computed tomography (CT). Lumbosacral CT scans and medical records were retrieved from data archives at three veterinary hospitals. Using previously published qualitative CT diagnostic criteria, a board-certified veterinary radiologist assigned dogs as either lumbosacral stenosis positive or lumbosacral stenosis negative at six vertebral locations. A second observer independently measured vertebral canal area, vertebral fat area, and vertebral body area; and calculated ratios of vertebral canal area/vertebral body area and vertebral fat area/vertebral body area (fat area ratio) at all six locations. Twenty-five dogs were sampled (lumbosacral stenosis negative, 11 dogs; lumbosacral stenosis positive, 14 dogs). Of the six locations, cranial L6 was the most affected by lumbosacral stenosis (33%). Five of six dogs (83%) with clinical signs of lumbosacral pain were lumbosacral stenosis positive at two or more levels. All four quantitative variables were significantly smaller at the cranial aspects of the L6 and L7 vertebral foramina than at the caudal aspects (P < 0.0001). Fat area ratio was a significant predictor of lumbosacral stenosis positive status at all six locations with cranial L6 having the greatest predictive value (R 2 = 0.43) and range of predictive probability (25-90%). Findings from the current study supported the use of CT as a deep phenotyping tool for future research studies of lumbosacral stenosis in Labrador retrievers. © 2017 American College of Veterinary Radiology.
Transverse sinus stenosis in adult patients with Chiari malformation type I.
Saindane, Amit M; Bruce, Beau B; Desai, Nilesh K; Roller, Lauren A; Newman, Nancy J; Biousse, Valérie
2014-10-01
Transverse sinus stenosis is an imaging finding very highly associated with elevated intracranial pressure (ICP). Patients with the Chiari I malformation may potentially have elevated ICP due to impairment of CSF flow at the foramen magnum. This study evaluated whether patients with Chiari I malformation have transverse sinus stenosis and other imaging findings indicative of elevated ICP. Thirty patients with Chiari I malformation treated surgically and 76 control subjects were identified retrospectively. All control subjects and all patients with Chiari I malformation (preoperatively) underwent standardized contrast-enhanced brain MRI including a contrast-enhanced 3D T1-weighted sequence from which curved reformats of the transverse sinuses were generated. Two different readers blinded to the diagnosis then independently evaluated these curved reformats for severity of transverse sinus stenosis. Orbital and skull-base findings previously described in association with elevated ICP were also evaluated. Frequency of MRI findings between the two groups was compared. Patients with Chiari I malformation had significantly greater frequency of unilateral or bilateral transverse sinus stenosis than did control subjects (p < 0.001). There was complete interreader agreement on presence or absence of transverse sinus stenosis by patient (κ = 1.0 [95% CI, 0.89-1.0]). Logistic regression analysis controlling for age, sex, and body mass index found that transverse sinus stenosis significantly predicted Chiari I malformation versus control status (odds ratio, 11.2 [95% CI, 2.1-59.0]; p = 0.004) but that no other features were significantly associated with the Chiari I malformation. Patients with Chiari I malformation who had transverse sinus stenosis had significantly greater pituitary flattening than did those without transverse sinus stenosis (p = 0.02). Patients with Chiari I malformation have higher likelihood of transverse sinus stenosis, which may reflect associated elevated ICP.
Atsumi, Kazushige; Shioyama, Yoshiyuki; Arimura, Hidetaka; Terashima, Kotaro; Matsuki, Takaomi; Ohga, Saiji; Yoshitake, Tadamasa; Nonoshita, Takeshi; Tsurumaru, Daisuke; Ohnishi, Kayoko; Asai, Kaori; Matsumoto, Keiji; Nakamura, Katsumasa; Honda, Hiroshi
2012-04-01
To determine clinical factors for predicting the frequency and severity of esophageal stenosis associated with tumor regression in radiotherapy for esophageal cancer. The study group consisted of 109 patients with esophageal cancer of T1-4 and Stage I-III who were treated with definitive radiotherapy and achieved a complete response of their primary lesion at Kyushu University Hospital between January 1998 and December 2007. Esophageal stenosis was evaluated using esophagographic images within 3 months after completion of radiotherapy. We investigated the correlation between esophageal stenosis after radiotherapy and each of the clinical factors with regard to tumors and therapy. For validation of the correlative factors for esophageal stenosis, an artificial neural network was used to predict the esophageal stenotic ratio. Esophageal stenosis tended to be more severe and more frequent in T3-4 cases than in T1-2 cases. Esophageal stenosis in cases with full circumference involvement tended to be more severe and more frequent than that in cases without full circumference involvement. Increases in wall thickness tended to be associated with increases in esophageal stenosis severity and frequency. In the multivariate analysis, T stage, extent of involved circumference, and wall thickness of the tumor region were significantly correlated to esophageal stenosis (p = 0.031, p < 0.0001, and p = 0.0011, respectively). The esophageal stenotic ratio predicted by the artificial neural network, which learned these three factors, was significantly correlated to the actual observed stenotic ratio, with a correlation coefficient of 0.864 (p < 0.001). Our study suggested that T stage, extent of involved circumference, and esophageal wall thickness of the tumor region were useful to predict the frequency and severity of esophageal stenosis associated with tumor regression in radiotherapy for esophageal cancer. Copyright © 2012 Elsevier Inc. All rights reserved.
Shibagaki, Kotaro; Ishimura, Norihisa; Oshima, Naoki; Mishiro, Tsuyoshi; Fukuba, Nobuhiko; Tamagawa, Yuji; Yamashita, Noritsugu; Mikami, Hironobu; Izumi, Daisuke; Taniguchi, Hideaki; Sato, Shuichi; Ishihara, Shunji; Kinoshita, Yoshikazu
2018-02-01
Endoscopic submucosal dissection (ESD) for extensive esophageal carcinomas may cause severe stenosis requiring endoscopic balloon dilations (EBDs). A standard prevention method has not been established. We propose the esophageal triamcinolone acetonide (TA)-filling method as a novel local steroid administration procedure. We enrolled 22 consecutive patients with early esophageal cancer who were treated using either subcircumferential or circumferential ESD (15 and 7 procedures, respectively) in this case series. Esophageal TA filling was performed on the day after ESD and 1 week later and was performed again if mild stenosis was found on follow-up. EBD with TA filling was performed only for severe stenosis that prevented endoscope passage. The primary endpoint was the incidence of severe stenosis. Secondary endpoints were the total number of EBDs and additional TA filling, dysphagia score, time to stenosis and to complete re-epithelialization, and any adverse events. The incidence of severe stenosis was 4.5% (1/22; confidence interval, .1%-22.8%), and EBD was performed 2 times in 1 patient. Mild stenosis was found in 9 patients. Additional TA filling was performed in 45.5% of patients (10/22; median, 5 times; range, 1-13). The dysphagia score deteriorated to 1 to 2 in 31.8% (7/22) but showed a final score of 0 after complete re-epithelialization in 90.9% (20/22). The median time to stenosis was 3 weeks (range, 3-4) and that to complete re-epithelialization was 7 weeks (range, 4-36). No severe adverse events occurred. The esophageal TA-filling method is highly effective for preventing severe stenosis after extensive esophageal ESD. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Atsumi, Kazushige; Shioyama, Yoshiyuki; Nakamura, Katsumasa; Nomoto, Satoshi; Ohga, Saiji; Yoshitake, Tadamasa; Nonoshita, Takeshi; Ueda, Masanobu; Hirata, Hideki; Honda, Hiroshi
2010-01-01
The purpose of this retrospective study was to clarify the predictive factors correlated with esophageal stenosis within three months after radiation therapy for locally advanced esophageal cancer. We enrolled 47 patients with advanced esophageal cancer with T2-4 and stage II-III who were treated with definitive radiation therapy and achieving complete response of primary lesion at Kyushu University Hospital between January 1998 and December 2005. Esophagography was performed for all patients before treatment and within three months after completion of the radiation therapy, the esophageal stenotic ratio was evaluated. The stenotic ratio was used to define four levels of stenosis: stenosis level 1, stenotic ratio of 0-25%; 2, 25-50%; 3,50-75%; 4,75-100%. We then estimated the correlation between the esophageal stenosis level after radiation therapy and each of numerous factors. The numbers and total percentages of patients at each stenosis level were as follows: level 1: n = 14 (30%); level 2: 8 (17%); level 3: 14 (30%); and level 4: 11 (23%). Esophageal stenosis in the case of full circumference involvement tended to be more severe and more frequent. Increases in wall thickness tended to be associated with increases in esophageal stenosis severity and frequency. The extent of involved circumference and wall thickness of tumor region were significantly correlated with esophageal stenosis associated with tumor regression in radiation therapy (p = 0.0006, p = 0.005). For predicting the possibility of esophageal stenosis with tumor regression within three months in radiation therapy, the extent of involved circumference and esophageal wall thickness of the tumor region may be useful.
Law, Y M; Tay, K H; Gan, Y U; Cheah, F K; Tan, B S
2008-04-01
To evaluate the accuracy of gadolinium-enhanced magnetic resonance angiography in assessing renal artery stenosis compared to catheter digital subtraction angiography. Retrospective study. Singapore General Hospital. Records of patients who underwent magnetic resonance angiography as well as digital subtraction angiography for assessment of renal artery stenosis from January 2003 to December 2005 were reviewed. There were 27 patients (14 male, 13 female) with a mean age of 62 (range, 44-77) years. There were 10 patients with renal transplants; their native renal arteries were not evaluated. Each of the two experienced interventional and body magnetic resonance radiologists, who were blinded to the results, reviewed the digital subtraction angiography and magnetic resonance angiography images respectively. Digital subtraction angiography was used as the standard of reference. A total of 39 renal arteries from these 27 patients were evaluated. One of the arteries was previously stented and could not be assessed with magnetic resonance angiography due to severe artefacts. Of the remaining 38 renal arteries, two were graded as normal, seven as having mild stenosis (<50%), eight as having moderate stenosis (> or =50% but <75%), and 21 as having severe stenosis (> or =75%). Magnetic resonance angiography and digital subtraction angiography were concordant in 89% of the arteries; magnetic resonance angiography overestimated the degree of stenosis in 8% and underestimated it in 3% of them. In the evaluation of clinically significant renal artery stenosis (> or =50%) with magnetic resonance angiography, the overall sensitivity, specificity, positive predictive value, and negative predictive value were 97%, 67%, 90%, and 86% respectively. The sensitivity and specificity of magnetic resonance angiography in transplant renal artery stenosis was 100%. CONCLUSION. Our experience suggested that gadolinium-enhanced magnetic resonance angiography is a sensitive non-invasive modality useful in the assessment of clinically significant renal artery stenosis.
Li, Xiaochuan; Bai, Xuedong; Wu, Yaohong; Ruan, Dike
2016-03-15
To construct and validate a model to predict responsible nerve roots in lumbar degenerative disease with diagnostic doubt (DD). From January 2009-January 2013, 163 patients with DD were assigned to the construction (n = 106) or validation sample (n = 57) according to different admission times to hospital. Outcome was assessed according to the Japanese Orthopedic Association (JOA) recovery rate as excellent, good, fair, and poor. The first two results were considered as effective clinical outcome (ECO). Baseline patient and clinical characteristics were considered as secondary variables. A multivariate logistic regression model was used to construct a model with the ECO as a dependent variable and other factors as explanatory variables. The odds ratios (ORs) of each risk factor were adjusted and transformed into a scoring system. Area under the curve (AUC) was calculated and validated in both internal and external samples. Moreover, calibration plot and predictive ability of this scoring system were also tested for further validation. Patients with DD with ECOs in both construction and validation models were around 76 % (76.4 and 75.5 % respectively). more preoperative visual analog pain scale (VAS) score (OR = 1.56, p < 0.01), stenosis levels of L4/5 or L5/S1 (OR = 1.44, p = 0.04), stenosis locations with neuroforamen (OR = 1.95, p = 0.01), neurological deficit (OR = 1.62, p = 0.01), and more VAS improvement of selective nerve route block (SNRB) (OR = 3.42, p = 0.02). the internal area under the curve (AUC) was 0.85, and the external AUC was 0.72, with a good calibration plot of prediction accuracy. Besides, the predictive ability of ECOs was not different from the actual results (p = 0.532). We have constructed and validated a predictive model for confirming responsible nerve roots in patients with DD. The associated risk factors were preoperative VAS score, stenosis levels of L4/5 or L5/S1, stenosis locations with neuroforamen, neurological deficit, and VAS improvement of SNRB. A tool such as this is beneficial in the preoperative counseling of patients, shared surgical decision making, and ultimately improving safety in spine surgery.
Bilateral adrenal phaeochromocytomas associated with unilateral renal artery stenosis.
Burns, A. P.; O'Connell, P. R.; Murnaghan, D. J.; Brady, M. P.
1989-01-01
A 21 year old male was discovered to be severely hypertensive. He was found to have bilateral adrenal phaeochromocytomas and a single renal artery stenosis. More than 40 cases of coexisting renal artery stenosis and phaeochromocytomas have been reported. The aetiology of renal artery stenosis in association with phaeochromocytoma maybe multifactorial and the radiographic appearances are not always clear-cut. Renin levels in this patient were elevated prior to the removal of the phaeochromocytomas but the renal vein renin ratio did not suggest that the renal artery stenosis contributed significantly to his hypertension. The patient's hypertension resolved following successful removal of the phaeochromocytomas despite persistence of the renal artery stenosis. Thus, though renin levels may be misleading in these cases, renal vein renin ratios may still be helpful in deciding on patient management. Images Figure 1 Figure 2 PMID:2694147
Original treatment for ischaemic stenosis of colon interposition: Report of two cases.
Daldoul, S; Moussi, A; Sayari, S; Ben Moussa, M
2017-02-01
The treatment of ischaemic stenosis of colon interposition for oesophageal replacement remains poorly defined. We report two cases of patients operated for ischaemic stenosis of the cervical extremity of the colon interposition for caustic stenosis of the oesophagus. Treatment consisted of resection of the stenosis with creation of a new cervical anastomosis after complete release of the colon graft via a neck and upper midline incision in one patient and a new ileocolic graft exclusively replacing the stenotic segment of the oesophagoplasty in the second patient. These two cases illustrate the complex treatment modalities required for this complication. The treatment of choice of ischaemic stenosis of colon interposition is resection with creation of a new anastomosis, but repeat graft may sometimes be the only available treatment option. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Long-term Outcome of Short Metallic Stents for Lobar Airway Stenosis.
Fruchter, Oren; Abed El Raouf, Bayya; Rosengarten, Dror; Kramer, Mordechai R
2017-07-01
Whereas stents are considered an excellent treatment for proximal central major airway stenosis, the value of stenting for distal lobar airway stenosis is still controversial. Our aim was to explore the short-term and long-term outcome of metallic stents placed for benign and malignant lobar airway stenosis. Between July 2007 and July 2014, 14 patients underwent small airway stent insertion. The clinical follow-up included serial semiannual physical examinations, pulmonary function tests, imaging, and bronchoscopy. The etiologies for airway stenosis were: early post-lung transplantation bronchial stenosis (N=5), sarcoidosis (N=1), amyloidosis (N=1), anthracofibrosis (N=1), right middle lobe syndrome due to external lymph node compression (N=1), lung cancer (N=4), and stenosis of the left upper lobe of unknown etiology (N=1). Stents were placed in the right upper lobe bronchus (N=2), right middle lobe bronchus (N=6), left upper lobe bronchus (N=4), linguar bronchus (N=1), and left lower lobe bronchus (N=1). The median follow-up period ranged from 2 to 72 months (median 18 mo). Immediate relief of symptoms was achieved in the vast majority of patients (13/14, 92%). Out of 10 patients with benign etiology for stenosis, 9 (90%) experienced sustained and progressive improvement in pulmonary function tests and clinical condition. We describe our positive experience with small stents for lobar airway stenosis; further prospective trials are required to evaluate the value of this novel modality of treatment.
Mesenchymal stem cell-derived extracellular vesicles attenuate kidney inflammation.
Eirin, Alfonso; Zhu, Xiang-Yang; Puranik, Amrutesh S; Tang, Hui; McGurren, Kelly A; van Wijnen, Andre J; Lerman, Amir; Lerman, Lilach O
2017-07-01
Mesenchymal stem/stromal cells (MSCs) have distinct capability for renal repair, but may have safety concerns. MSC-derived extracellular vesicles emerged as a novel noncellular alternative. Using a porcine model of metabolic syndrome and renal artery stenosis we tested whether extracellular vesicles attenuate renal inflammation, and if this capacity is mediated by their cargo of the anti-inflammatory cytokine interleukin (IL) 10. Pigs with metabolic syndrome were studied after 16 weeks of renal artery stenosis untreated or treated four weeks earlier with a single intrarenal delivery of extracellular vesicles harvested from adipose tissue-derived autologous MSCs. Lean and sham metabolic syndrome animals served as controls (seven each). Five additional pigs with metabolic syndrome and renal artery stenosis received extracellular vesicles with pre-silenced IL10 (IL10 knock-down). Single-kidney renal blood flow, glomerular filtration rate, and oxygenation were studied in vivo and renal injury pathways ex vivo. Retention of extracellular vesicles in the stenotic kidney peaked two days after delivery and decreased thereafter. Four weeks after injection, extracellular vesicle fragments colocalized with stenotic-kidney tubular cells and macrophages, indicating internalization or fusion. Extracellular vesicle delivery attenuated renal inflammation, and improved medullary oxygenation and fibrosis. Renal blood flow and glomerular filtration rate fell in metabolic syndrome and renal artery stenosis compared to metabolic syndrome, but was restored in pigs treated with extracellular vesicles. These renoprotective effects were blunted in pigs treated with IL10-depleted extracellular vesicles. Thus, extracellular vesicle-based regenerative strategies might be useful for patients with metabolic syndrome and renal artery stenosis. Copyright © 2017 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.
Chen, Wenxian; Gao, Pengfei; Cui, Pengcheng; Ruan, Yanyan; Liu, Zhi; Sun, Yongzhu; Bian, Ka
2016-01-01
To systematically study various surgical approaches for treating complex hypopharyngeal and/or laryngotracheal stenoses at a variety of sites and levels. We retrospectively analyzed the treatment of 17 patients with severe and complex hypopharyngeal and/or laryngotracheal stenosis at various sites and levels of severity. All of the 17 patients initially had a tracheostomy. Thirteen had failed the previous laser lysis and/or dilation treatment. Given the high severity and complexity of stenosis, all of these patients were treated by open surgical reconstruction techniques using repairing grafts (flaps), followed by stenting. Thirteen of 17 patients had successful decannulation 1-8 months post-operation and had stable airway and adequate vocal and swallow function. Two patients with complex hypopharyngeal and esophageal stenosis had unsuccessful decannulation. Follow-up was lost in 1 patient with complex hypopharyngeal and esophageal stenosis and 1 patient with original hypopharyngeal stenosis and recurrent thoracotracheal stenosis. Despite the failure by the regular treatments using laser lysis and/or dilation therapy, severe and complex hypopharyngeal and/or laryngotracheal stenosis may be successfully treated by variable open surgical reconstruction techniques using different grafts (flaps) depending on the site and severity of the stenosis. © 2016 S. Karger AG, Basel.
CO laser angioplasty system: efficacy of manipulatable laser angioscope catheter
NASA Astrophysics Data System (ADS)
Arai, Tsunenori; Kikuchi, Makoto; Mizuno, Kyoichi; Sakurada, Masami; Miyamoto, Akira; Arakawa, Koh; Kurita, Akira; Nakamura, Haruo; Takeuchi, Kiyoshi; Utsumi, Atsushi; Akai, Yoshiro
1992-08-01
A percutaneous transluminal coronary angioplasty system using a unique combination of CO laser (5 micrometers ) and As-S infrared glass fiber under the guidance of a manipulatable laser angioscope catheter is described. The ablation and guidance functions of this system are evaluated. The angioplasty treatment procedure under angioscope guidance was studied by in vitro model experiment and in vivo animal experiment. The whole angioplasty system is newly developed. That is, a transportable compact medical CO laser device which can emit up to 10 W, a 5 F manipulatable laser angioscope catheter, a thin CO laser cable of which the diameter is 0.6 mm, an angioscope imaging system for laser ablation guidance, and a system controller were developed. Anesthetized adult mongrel dogs (n equals 5) with an artificial complete occlusion in the femoral artery and an artificial human vessel model including occluded or stenotic coronary artery were used. The manipulatability of the catheter was drastically improved (both rotation and bending), therefore, precise control of ablation to expand stenosis was obtained. A 90% artificial stenosis made of human yellow plaque in 4.0 mm diameter in the vessel was expanded to 70% stenosis by repetitive CO laser ablations of which total energy was 220 J. All procedures were performed and controlled under angioscope visualization.
Yagmurlu, Aydin; Vargun, Rahsan; Gollu, Gulnur; Gokcora, I Haluk
2004-01-01
A neonate with penile agenesis and congenital hypertrophic pyloric stenosis is presented. The patterns of associated anomalies with penile agenesis, and those of congenital hypertrophic pyloric stenosis are discussed.
The left ventricle in aortic stenosis--imaging assessment and clinical implications.
Călin, Andreea; Roşca, Monica; Beladan, Carmen Cristiana; Enache, Roxana; Mateescu, Anca Doina; Ginghină, Carmen; Popescu, Bogdan Alexandru
2015-04-29
Aortic stenosis has an increasing prevalence in the context of aging population. In these patients non-invasive imaging allows not only the grading of valve stenosis severity, but also the assessment of left ventricular function. These two goals play a key role in clinical decision-making. Although left ventricular ejection fraction is currently the only left ventricular function parameter that guides intervention, current imaging techniques are able to detect early changes in LV structure and function even in asymptomatic patients with significant aortic stenosis and preserved ejection fraction. Moreover, new imaging parameters emerged as predictors of disease progression in patients with aortic stenosis. Although proper standardization and confirmatory data from large prospective studies are needed, these novel parameters have the potential of becoming useful tools in guiding intervention in asymptomatic patients with aortic stenosis and stratify risk in symptomatic patients undergoing aortic valve replacement.This review focuses on the mechanisms of transition from compensatory left ventricular hypertrophy to left ventricular dysfunction and heart failure in aortic stenosis and the role of non-invasive imaging assessment of the left ventricular geometry and function in these patients.
A bronchoscopic approach to benign subglottic stenosis.
Raman, Tuhina; Chatterjee, Kshitij; Alzghoul, Bashar N; Innabi, Ayoub A; Tulunay, Ozlem; Bartter, Thaddeus; Meena, Nikhil K
2017-01-01
Subglottic stenosis is an abnormal narrowing of the tracheal lumen at the level of subglottis (the area in between the vocal cords and the cricoid cartilage). It can cause significant symptoms due to severe attenuation of airflow. We describe our experience in alleviating symptoms by addressing the stenosis using fibreoptic bronchoscopic methods. We report all concurrent cases performed between September 2015 and July 2016. We use a combination of balloon dilation, electro-surgery knife to dilate and incise stenotic segments followed by steroid injection to modulate healing. We treated 10 patients in the study period, 8 of which were women. A total of 39 procedures were performed on these patients during this period. Gastro-esophageal reflux was the most common comorbidity associated with stenosis. The majority of the patients required more than 2 therapeutic procedures, but none required more than 4 procedures. There were no complications. Tracheal stenosis and in particular subglottic stenosis is a recurrent process and its management requires extensive collaboration amongst treating specialties. Our technique of steroid injection after dilation of the stenosis was effective in symptom control and decreased the number of repeat procedures.
Stenosis of esophago-jejuno anastomosis after gastric surgery.
Fukagawa, Takeo; Gotoda, Takuji; Oda, Ichiro; Deguchi, Yasunori; Saka, Makoto; Morita, Shinji; Katai, Hitoshi
2010-08-01
Stenosis of esophago-jejuno anastomosis is one of the postoperative complications of gastric surgery. This complication usually manifests with the symptom of dysphagia and is treated by endoscopic dilatation. No large-scale studies have been conducted to determine the incidence of this complication after surgery. The data of a total of 1478 consecutive patients who underwent total, proximal, or completion gastrectomy, including esophago-jejuno anastomosis, between 2000 and 2008 were analyzed retrospectively with a view to determining the incidence of anastomotic stenosis. Sixty patients (4.1%) developed stenosis of the esophago-jejuno anastomosis which needed to be treated by endoscopic balloon dilatation. The average interval between the surgery and detection of stenosis was 67.4 days (median = 58.0). Multivariate analysis identified female gender, proximal gastrectomy, use of a narrow-sized stapler, and the choice of the stapling device as significant factors influencing the risk of development of anastomotic stenosis. Esophago-jejuno anastomotic stenosis appears to be a common late postoperative complication after gastric surgery. Endoscopic examination and treatment yielded favorable outcomes in patients complaining of dysphagia after gastric surgery.
Transcatheter aortic valve replacement
... fully will restrict blood flow. This is called aortic stenosis. If there is also a leak, it is ... TAVR is used for people with severe aortic stenosis who aren't ... valve . In adults, aortic stenosis usually occurs due to calcium ...
Diagnosis of Lumbar Foraminal Stenosis using Diffusion Tensor Imaging.
Eguchi, Yawara; Ohtori, Seiji; Suzuki, Munetaka; Oikawa, Yasuhiro; Yamanaka, Hajime; Tamai, Hiroshi; Kobayashi, Tatsuya; Orita, Sumihisa; Yamauchi, Kazuyo; Suzuki, Miyako; Aoki, Yasuchika; Watanabe, Atsuya; Kanamoto, Hirohito; Takahashi, Kazuhisa
2016-02-01
Diagnosis of lumbar foraminal stenosis remains difficult. Here, we report on a case in which bilateral lumbar foraminal stenosis was difficult to diagnose, and in which diffusion tensor imaging (DTI) was useful. The patient was a 52-year-old woman with low back pain and pain in both legs that was dominant on the right. Right lumbosacral nerve compression due to a massive uterine myoma was apparent, but the leg pain continued after a myomectomy was performed. No abnormalities were observed during nerve conduction studies. Computed tomography and magnetic resonance imaging indicated bilateral L5 lumbar foraminal stenosis. DTI imaging was done. The extraforaminal values were decreased and tractography was interrupted in the foraminal region. Bilateral L5 vertebral foraminal stenosis was treated by transforaminal lumbar interbody fusion and the pain in both legs disappeared. The case indicates the value of DTI for diagnosing vertebral foraminal stenosis.
Small interfering RNA targeting nuclear factor kappa B to prevent vein graft stenosis in rat models.
Meng, X B; Bi, X L; Zhao, H L; Feng, J B; Zhang, J P; Song, G M; Sun, W Y; Bi, Y W
2013-01-01
Intimal hyperplasia plays an important role in vein graft stenosis. Inflammatory injury, especially nuclear factor kappaB (NF-κB) gene activation, is highly involved in stenosis progression. We examined whether neointimal hyperplasia and vein graft stenosis could be inhibited by silencing the NF-κB gene with small interference RNA (siRNA). Sixty adult male Sprague-Dawley rats were randomly divided into a normal vein group, a vein graft group, a scrambled siRNA group, and an NF-κB siRNA group. We performed reverse interpositional grafting of the autologous external jugular vein to the abdominal aorta. Vein grafts were treated with liposome and gel complexes containing NF-κB siRNA or scrambled siRNA. The levels of monocyte chemoattractant protein -1, tumor necrosis factor-α, and NF-κB p65 in vessel tissues were evaluated after surgery for content of proliferating cell nuclear antigen (PCNA) and vascular wall thickness. NF-κB siRNA treated vein graft showed less neointimal formation and fewer positive PCNA cells (P < .05). In addition there were lower levels of, NF-κB p65 protein and of inflammatory mediators (P < .05) compared with the vein graft group. Our study suggested that siRNA transfection suppressed NF-κB expression, reduced inflammatory factors, lessened neointimal proliferation, and suppressed PCNA. Copyright © 2013 Elsevier Inc. All rights reserved.
Venous thrombosis and stenosis after peripherally inserted central catheter placement in children.
Shin, H Stella; Towbin, Alexander J; Zhang, Bin; Johnson, Neil D; Goldstein, Stuart L
2017-11-01
Peripherally inserted central catheters (PICCs) can lead to development of venous thrombosis and/or stenosis. The presence of venous thrombosis and/or stenosis may preclude children with chronic medical conditions from receiving lifesaving therapies, from hemodialysis in end-stage renal disease to total parenteral nutrition in short bowel syndrome. Several adult studies have found an association between PICCs and venous thrombosis and/or stenosis, but none has evaluated for this association in children. To determine the incidence of venous thrombosis and/or stenosis after PICC placement and identify factors that increase the risk of venous thrombosis and/or stenosis after PICC placement in children. We conducted a retrospective review of children ages 1-18 years with a PICC placed between January 2010 and July 2013 at our center, and included those who had at least one vascular imaging study of the ipsilateral extremity (Doppler ultrasound, venogram or MR angiogram) after PICC placement. Logistic regression was applied to determine risk factors for development of venous thrombosis and/or stenosis. One thousand, one hundred and ten upper extremity PICCs were placed, with 703 PICCs in the right and 407 PICCs in the left. Eight hundred fifty-one imaging studies (609 Doppler ultrasounds, 193 contrast venograms and 49 MR angiograms) were performed in 376 patients. The incidence of venous thrombosis and/or stenosis in the imaged cohort was 26.3%. PICC laterality, insertion site, duration, patient height to PICC diameter ratio, and number of PICCs per patient were not associated with development of venous thrombosis and/or stenosis. Additionally, primary diagnosis and symptoms at the time of imaging did not predict findings of venous thrombosis and/or stenosis. However, patients exposed to non-PICC central venous catheters (CVC) were more likely to develop venous thrombosis and/or stenosis (odds ratio 1.95, 1.10-3.45). More than a quarter of the vascular imaging studies performed in this study cohort showed previously unknown venous thrombosis and/or stenosis, irrespective of PICC laterality, insertion site, duration and size and the number of PICCs. A history of CVC was associated with a nearly two-fold increase in risk of venous thrombosis and/or stenosis after PICC placement. We suggest that PICCs and CVCs should be placed judiciously in all children, but especially in those with lifelong medical conditions who are more likely to incur direct consequences from limited vascular access.
Chien, Kuang-Jen; Huang, Hurng-Wern; Huang, Ta-Cheng; Lee, Cheng-Liang; Weng, Ken-Pen; Lin, Chu-Chuan; Shieh, Po-Chuen; Wu, Ming-Ting; Hsieh, Kai-Sheng
2016-01-01
The aim of this study was to compare the usefulness of lung perfusion scintigraphy and echocardiogram in the evaluation of the branch pulmonary arteries stenosis in children with tetralogy of Fallot (TOF). From February 2006 to November 2008, 74 children (mean age 7.8 years, range 1–18 years) who underwent repair of TOF at ages from 10 months to 13 years were suspected to have unilateral or bilateral branch pulmonary artery stenosis. In all patients, cardiac angiography was performed to confirm the diagnosis of branch pulmonary artery stenosis. Lung perfusion scintigraphy and two-dimensional transthoracic echocardiography were performed in all patients to compare their abilities to diagnose branch pulmonary artery stenosis. Of the 74 patients, 51 cases were found to have branch pulmonary artery stenosis by cardiac angiography. There was agreement between the scintigraphic and angiographic findings in 44 (86%) patients and there were discrepancies in 11 (15%) patients. The positive predictive value of our lung perfusion scintigraphy in detecting the branch pulmonary artery stenosis was 92 %. The positive and negative likelihood ratios of lung perfusion scintigraphy were 4.96 and 0.17, respectively. There was conformity between the echocardiographic and angiographic findings in 40 (78%) patients with discrepancies in 16 (21%) patients. The positive predictive value of our echocardiography in detecting the branch pulmonary artery stenosis was 89%. The positive and negative likelihood ratios of echocardiography were 3.61 and 0.28, respectively. Lung perfusion scintigraphy is a valuable, non-invasive screening tool in the assessment of branch pulmonary artery stenosis in children after TOF.
Kieves, Nina R; Novo, Roberto E; Martin, Robert B
2011-10-01
CASE DESCRIPTION-4 dogs were evaluated because of recurrent urinary tract infections. CLINICAL FINDINGS-All dogs had recurrent urinary tract infections and similar clinical signs; 3 dogs had urinary incontinence. Digital vaginal examination revealed vestibulovaginal stenosis in all dogs, which was confirmed by results of contrast vaginourethrography. From image measurements, the vestibulovaginal ratio (ratio of the height of the vestibulovaginal junction to the maximum height of the vagina on a lateral vaginourethrogram) was calculated for each dog. Three dogs had severe stenosis (vestibulovaginal ratio, < 0.20; severe stenosis is defined as a vestibulovaginal ratio < 0.20), whereas the fourth dog had moderate stenosis (vestibulovaginal ratio, 0.24; ratio range for moderate stenosis is 0.20 to 0.25). TREATMENT AND OUTCOME-All dogs were anesthetized for surgical correction of the vestibulovaginal stenosis. Vaginal resection and anastomosis of the stenosis was performed in all 4 dogs, with 1 dog also undergoing episioplasty. Complete resolution of clinical signs was apparent in 3 dogs; 1 dog had postoperative complications including pollakiuria and stranguria, which resulted in rectal and vaginal prolapse. This dog underwent ovariohysterectomy, after which clinical signs resolved. All dogs had resolution of urinary tract infections at the time of follow-up (6 to 8 months after surgery). CLINICAL RELEVANCE-Resection and anastomosis may resolve recurrent urinary tract infections in dogs with severe or moderate vestibulovaginal stenosis. Episiotomy was not necessary for success of surgical treatment, and overall, that procedure increased morbidity, the severity of intraoperative hemorrhage, and duration of surgery.
Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M
2008-11-01
To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.
Lumbar scoliosis associated with spinal stenosis in idiopathic and degenerative cases.
Le Huec, J C; Cogniet, A; Mazas, S; Faundez, A
2016-10-01
Degenerative de novo scoliosis is commonly present in older adult patients. The degenerative process including disc bulging, facet arthritis, and ligamentum flavum hypertrophy contributes to the appearance of symptoms of spinal stenosis. Idiopathic scoliosis has also degenerative changes that can lead to spinal stenosis. The aetiology, prevalence, biomechanics, classification, symptomatology, and treatment of idiopathic and degenerative lumbar scoliosis in association with spinal stenosis are reviewed. Review study is based on a review of pertinent but non-exhaustive literature of the last 20 years in PubMed in English language. Retrospective analysis of studies focused on all parameters concerning scoliosis associated with stenosis. Very few publications have focused specifically on idiopathic scoliosis and stenosis, and this was before the advent of modern segmental instrumentation. On the other hand, many papers were found for degenerative scoliosis and stenosis with treatment methods based on aetiology of spinal canal stenosis and analysis of global sagittal and frontal parameters. Satisfactory clinical results after operative treatment range from 83 to 96 % but with increased percentage of complications. Recent literature analysed the importance of stabilizing or not the spine after decompression in such situation knowing the increasing risk of instability after facet resection. No prospective randomized studies were found to support short instrumentation. Long instrumentation and fusion to prevent distabilization after decompression were always associated with higher complication rates. Imbalance patients with unsatisfactory compensation capacities were at risk of complications. Operative treatment using newly proposed classification system of lumbar scoliosis with associated canal stenosis is useful. Sagittal balance and rotatory dislocation are the main parameters to analyse to determine the length of fusion.
Jacobs, Jordan V; Hill, David A; Petersen, Scott R; Bremner, Ross M; Sue, Richard D; Smith, Michael A
2013-03-01
The short-term safety of percutaneous dilatational tracheostomy has been widely demonstrated. However, less is known about their long-term complications. Through an illustrative case series, we present and define "corkscrew stenosis," a type of tracheal stenosis uniquely associated with percutaneous dilatational tracheostomy. Patients treated at our institution for tracheal stenosis after percutaneous dilatational tracheostomy were reviewed. Demographic data including gender, age, history of presentation, lesion morphology, imaging, and management was collected and evaluated. The pathology of the stenosis and the strategies for prevention are presented. From January, 2008 through December 2011, 11 patients had tracheal stenosis after percutaneous dilatational tracheostomy. The mean age was 54 ± 17 years and 55% were male. The stenotic lesions were characterized by a corkscrew morphology at the stoma site with a mean distance of 2.3 ± 0.8 cm from the vocal cords. Images of these lesions demonstrated disruption and fracture of the proximal tracheal cartilages and displacement of the anterior tracheal wall into the tracheal lumen. The majority of our patients required tracheal resection for definitive repair. We suggest that a unique form of tracheal stenosis can result from percutaneous dilatational tracheostomy. We observed corkscrew stenosis to be located proximally, associated with fractured tracheal rings, and morphologically appearing as interdigitation of these fractured rings. Recognizing corkscrew stenosis, its unique mechanism of formation, and technical means of prevention may be important in advancing the long-term safety of this procedure for critically ill patients who require prolonged ventilatory support. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Wang, Shuang; Guo, Zhen-Ni; Xing, Yingqi; Ma, Hongyin; Jin, Hang; Liu, Jia; Yang, Yi
2015-01-01
Abstract The aim of the study was to assess the capacity of dynamic cerebral autoregulation (dCA) in asymptomatic patients with unilateral middle cerebral artery (MCA) stenosis. Fifty-seven patients with asymptomatic mild, moderate, and severe unilateral MCA stenosis and 8 patients with symptomatic severe unilateral MCA stenosis diagnosed by transcranial Doppler were enrolled. Twenty-four healthy volunteers served as controls. The noninvasive continuous cerebral blood flow velocity and arterial blood pressure were recorded simultaneously from each subject in the supine position. Transfer function analysis was applied to determine the autoregulatory parameters (phase difference [PD] and gain). The PD values in the severe stenosis groups were significantly lower than those of the control group (60.71 ± 18.63°), the asymptomatic severe stenosis group was impaired ipsilaterally (28.94 ± 27.43°, P < 0.001), and the symptomatic severe stenosis group was impaired bilaterally (13.74 ± 19.21°, P < 0.001; 19.68 ± 14.50°, P = 0.006, respectively). The PD values in the mild and moderate stenosis groups were not significantly different than the controls (44.49 ± 27.93°; 48.65 ± 25.49°, respectively). The gain values in the mild and moderate groups were higher than in the controls (1.00 ± 0.58 cm/s/mm Hg vs 0.86 ± 0.34 cm/s/mm Hg, and 1.20 ± 0.59 cm/s/mm Hg vs 0.86 ± 0.34 cm/s/mm Hg, respectively). The gain values in the severe stenosis groups were significantly lower than that in the control group: the asymptomatic severe stenosis group was lower bilaterally (0.56 ± 0.32 cm/s/mm Hg, P = 0.003; 0.60 ± 0.32 cm/s/mm Hg, P < 0.05, respectively), whereas the symptomatic severe group was lower unilaterally (on the contralateral side) (0.53 ± 0.43 cm/s/mm Hg, P < 0.05). In asymptomatic patients with unilateral MCA stenosis, only the dCA of the severe stenosis was ipsilaterally impaired. Acute stroke may aggravate the impaired dCA and even spread contralaterally. PMID:26717363
[Heart failure provoked by a pacemaker lead-induced tricuspid stenosis].
Chaudesaygues, E; Ferrini, M; Ritz, B
2017-04-01
Tricuspid stenosis (TS) is an uncommon complication of ventricular pacemaker implantation. Mechanisms described by the literature are ventricular inflow obstruction by tricuspid vegetations (endocarditis) or multiple pacemaker leads and fibrosis secondary to mechanical trauma, accounting for perforation or laceration of the TV leaflets, or adherence between redundant loops and valve tissue. We present the case of iatrogenic tricuspid stenosis, observed in a 77-year-old man. Extrinsic tricuspid valve stenosis was detected by transthoracic echocardiography. Further investigations confirmed the intramyocardial lead position. Tricuspid valve stenosis due to transvenous leads are reported to be treated by surgical replacement, surgical valvuloplasty, or percutaneous balloon valvuloplasty. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Patanè, Salvatore; Marte, Filippo; Di Bella, Gianluca; Di Tommaso, Eleonora; Pagano, Giuseppina Tindara; Coglitore, Sebastiano
2009-04-03
Pulmonary stenosis comprises variable pathologic features from the right ventricular outflow tract to the peripheral pulmonary arteries. Most frequently, the obstruction occurs at the level of the pulmonary valve; however, it occurs less frequently at the infindibular level. It can occur as part of more congenital cardiac malformations such as tetralogy of Fallot, complete transposition of great arteries, or atrial septal defect. Proximal pulmonary artery stenosis has also been reported as an acquired lesion in infants treated for congenital heart disease. Primary isolated supravalvular pulmonary stenosis is less common. We present a case of primary isolated pulmonary artery stenosis in an asymptomatic 25-day-old newborn infant.
Application of the NUREG/CR-6850 EPRI/NRC Fire PRA Methodology to a DOE Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tom Elicson; Bentley Harwood; Richard Yorg
2011-03-01
The application NUREG/CR-6850 EPRI/NRC fire PRA methodology to DOE facility presented several challenges. This paper documents the process and discusses several insights gained during development of the fire PRA. A brief review of the tasks performed is provided with particular focus on the following: • Tasks 5 and 14: Fire-induced risk model and fire risk quantification. A key lesson learned was to begin model development and quantification as early as possible in the project using screening values and simplified modeling if necessary. • Tasks 3 and 9: Fire PRA cable selection and detailed circuit failure analysis. In retrospect, it wouldmore » have been beneficial to perform the model development and quantification in 2 phases with detailed circuit analysis applied during phase 2. This would have allowed for development of a robust model and quantification earlier in the project and would have provided insights into where to focus the detailed circuit analysis efforts. • Tasks 8 and 11: Scoping fire modeling and detailed fire modeling. More focus should be placed on detailed fire modeling and less focus on scoping fire modeling. This was the approach taken for the fire PRA. • Task 14: Fire risk quantification. Typically, multiple safe shutdown (SSD) components fail during a given fire scenario. Therefore dependent failure analysis is critical to obtaining a meaningful fire risk quantification. Dependent failure analysis for the fire PRA presented several challenges which will be discussed in the full paper.« less
2007-05-25
allergy E Patient is discharged on hydralazine/nitrate therapy* E Hypotension* El Moderate or severe aortic stenosis El Worsening renal function* E...Hypotension* E Moderate or severe aortic stenosis El Worsening renal function* E Hyperkalemia* E Bilateral renal artery stenosis * E Pregnancy* E Other...Hyperkalemia* El Bilateral renal artery stenosis * E Pregnancy* El Other - must be documented in medical record Angiotension Receptor Blocker (ARB
Kintzelé, Laurent; Rehnitz, Christoph; Kauczor, Hans-Ulrich; Weber, Marc-André
2018-06-06
To identify whether standard sagittal MRI images result in underestimation of the neuroforaminal stenosis grade compared to oblique sagittal MRI images in patients with cervical spine disc herniation. 74 patients with a total of 104 cervical disc herniations compromising the corresponding nerve root were evaluated. Neuroforaminal stenosis grades were evaluated in standard and oblique sagittal images by one senior and one resident radiologist experienced in musculoskeletal imaging. Oblique images were angled 30° towards the standard sagittal plane. Neuroforaminal stenosis grades were classified from 0 (no stenosis) to 3 (high grade stenosis). Average neuroforaminal stenosis grades of both readers were significantly lower in standard compared to oblique sagittal images (p < 0.001). For 47.1 % of the cases, one or both readers reported a stenosis grade, which was at least 1 grade lower in standard compared to oblique sagittal images. There was also a significant difference when looking at patients who had neurological symptoms (p = 0.002) or underwent cervical spine surgery subsequently (p = 0.004). Interreader reliability, as measured by kappa value, and accordance rates were better for oblique sagittal images (0.94 vs. 0.88 and 99 % vs. 93 %). Standard sagittal images tend to underestimate neuroforaminal stenosis grades compared to oblique sagittal images and are less reliable in the evaluation of disc herniations within the cervical spine MRI. In order to assess the potential therapeutic consequence, oblique images should therefore be considered as a valuable adjunct to the standard MRI protocol for patients with a radiculopathy. · Neuroforaminal stenosis grades are underestimated in standard compared to oblique sagittal images. · Interreader reliability is higher for oblique sagittal images. · Oblique sagittal images should be performed in patients with a cervical radiculopathy. · Kintzele L, Rehnitz C, Kauczor H et al. Oblique Sagittal Images Prevent Underestimation of the Neuroforaminal Stenosis Grade Caused by Disc Herniation in Cervical Spine MRI. Fortschr Röntgenstr 2018; DOI: 10.1055/a-0612-8205. © Georg Thieme Verlag KG Stuttgart · New York.
Effect of Blood Shear Forces on Platelet Mediated Thrombosis Inside Arterial Stenosis.
NASA Astrophysics Data System (ADS)
Maalej, Nabil
Shear induced activation of platelets plays a major role in the onset of thrombosis in atherosclerotic arteries. Blood hemodynamics and its effect on platelet kinetics has been studied mainly in in vitro and in ex vivo experiments. We designed new in vivo methods to study blood hemodynamic effects on platelet kinetics in canine stenosed carotid arteries. A carotid artery-jugular vein anastomotic shunt was produced. Intimal damage and controlled variations in the degree of stenosis were produced on the artery. An inflatable cuff was placed around the jugular vein to control vascular resistance. An electromagnetic flowmeter was used to measure blood flow. Doppler ultrasound crystals were used to measure the velocity profiles inside and distal to the stenosis. Stenosis geometry was obtained using digital subtraction angiography and quantitative arteriography. Using these measurements we calculated the wall shear stress using the finite difference solution of the Navier-Stokes equations. To study platelet kinetics, autologous platelets were labeled with Indium Oxine and injected IV. A collimated Nal gamma counter was placed over the stenosis to detect radio-labeled platelet accumulation as platelet mediated thrombi formed in the stenosis. The radioactive count rate increased in an inverse parallel fashion to the decline in flow rate during thrombus formation. The platelet accumulation increased with the increase of percent stenosis and was maximal at the narrow portion of the stenosis. Acute thrombus formation leading to arterial occlusion was only observed for stenosis higher than 70 +/- 5%. Platelet accumulation rate was not significant until the pressure gradient across the stenosis exceeded 40 +/- 10 mmHg. Totally occlusive thrombus formation was only observed for shear stresses greater than a critical value of 100 +/- 10 Pa. Beyond this critical value acute platelet thrombus formation increased exponentially with shear. Increased shear stresses were found to overcome the antithrombotic effect of aspirin. Critical levels of shear might be produced clinically at sites of arterial lesions by a sudden change in blood hemodynamics or flow geometry. This may put a patient with arterial stenosis at greater risk of acute thrombus formation leading to stroke or myocardial infarction.
Kim, Jun Won; Kim, Tae Hyung; Kim, Jie-Hyun; Lee, Ik Jae
2018-01-01
AIM To evaluate toxicity and treatment outcome of high-dose radiotherapy (RT) for cervical esophageal cancer (CEC). METHODS We reviewed a total of 62 consecutive patients who received definitive RT for stage I to III cervical esophageal cancer between 2001 and 2015. Patients who received < 45 Gy, treated for lesions below sternal notch, treated with palliative aim, treated with subsequent surgical resection, or diagnosed with synchronous hypopharyngeal cancer were excluded. Treatment failures were divided into local (occurring within the RT field), outfield-esophageal, and regional [occurring in regional lymph node(s)] failures. Factors predictive of esophageal stenosis requiring endoscopic dilation were analyzed. RESULTS Grade 1, 2, and 3 esophagitis occurred in 19 (30.6%), 39 (62.9%), and 4 patients (6.5%), respectively, without grade ≥ 4 toxicities. Sixteen patients (25.8%) developed post-RT stenosis, of which 7 cases (43.8%) were malignant. Four patients (6.5%) developed tracheoesophageal fistula (TEF), of which 3 (75%) cases were malignant. Factors significantly correlated with post-RT stenosis were stage T3/4 (P = 0.001), complete circumference involvement (P < 0.0001), stenosis at diagnosis (P = 0.024), and endoscopic complete response (P = 0.017) in univariate analysis, while complete circumference involvement was significant in multivariate analysis (P = 0.003). A higher dose (≥ 60 Gy) was not associated with occurrence of post-RT stenosis or TEF. With a median follow-up of 24.3 (range, 3.4-152) mo, the 2 y local control, outfield esophageal control, progression-free survival, and overall survival (OS) rates were 78.9%, 90.2%, 49.6%, and 57.3%, respectively. Factors significantly correlated with OS were complete circumference involvement (P = 0.023), stenosis at diagnosis (P < 0.0001), and occurrence of post-RT stenosis or TEF (P < 0.001) in univariate analysis, while stenosis at diagnosis (P = 0.004) and occurrence of post-RT stenosis or TEF (P = 0.023) were significant in multivariate analysis. CONCLUSION Chemoradiation for CEC was well tolerated, and a higher dose was not associated with stenosis. Patients with complete circumferential involvement require close follow-up. PMID:29467556
Kim, Jun Won; Kim, Tae Hyung; Kim, Jie-Hyun; Lee, Ik Jae
2018-02-21
To evaluate toxicity and treatment outcome of high-dose radiotherapy (RT) for cervical esophageal cancer (CEC). We reviewed a total of 62 consecutive patients who received definitive RT for stage I to III cervical esophageal cancer between 2001 and 2015. Patients who received < 45 Gy, treated for lesions below sternal notch, treated with palliative aim, treated with subsequent surgical resection, or diagnosed with synchronous hypopharyngeal cancer were excluded. Treatment failures were divided into local (occurring within the RT field), outfield-esophageal, and regional [occurring in regional lymph node(s)] failures. Factors predictive of esophageal stenosis requiring endoscopic dilation were analyzed. Grade 1, 2, and 3 esophagitis occurred in 19 (30.6%), 39 (62.9%), and 4 patients (6.5%), respectively, without grade ≥ 4 toxicities. Sixteen patients (25.8%) developed post-RT stenosis, of which 7 cases (43.8%) were malignant. Four patients (6.5%) developed tracheoesophageal fistula (TEF), of which 3 (75%) cases were malignant. Factors significantly correlated with post-RT stenosis were stage T3/4 ( P = 0.001), complete circumference involvement ( P < 0.0001), stenosis at diagnosis ( P = 0.024), and endoscopic complete response ( P = 0.017) in univariate analysis, while complete circumference involvement was significant in multivariate analysis ( P = 0.003). A higher dose (≥ 60 Gy) was not associated with occurrence of post-RT stenosis or TEF. With a median follow-up of 24.3 (range, 3.4-152) mo, the 2 y local control, outfield esophageal control, progression-free survival, and overall survival (OS) rates were 78.9%, 90.2%, 49.6%, and 57.3%, respectively. Factors significantly correlated with OS were complete circumference involvement ( P = 0.023), stenosis at diagnosis ( P < 0.0001), and occurrence of post-RT stenosis or TEF ( P < 0.001) in univariate analysis, while stenosis at diagnosis ( P = 0.004) and occurrence of post-RT stenosis or TEF ( P = 0.023) were significant in multivariate analysis. Chemoradiation for CEC was well tolerated, and a higher dose was not associated with stenosis. Patients with complete circumferential involvement require close follow-up.
Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh
2015-04-22
Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.
Nguyen, Louis L; Smith, Ann D; Scully, Rebecca E; Jiang, Wei; Learn, Peter A; Lipsitz, Stuart R; Weissman, Joel S; Helmchen, Lorens A; Koehlmoos, Tracey; Hoburg, Andrew; Kimsey, Linda G
2017-06-01
Although many factors influence the management of carotid artery stenosis, it is not well understood whether a preference toward procedural management exists when procedural volume and physician compensation are linked in the fee-for-service environment. To explore evidence for provider-induced demand in the management of carotid artery stenosis. The Department of Defense Military Health System Data Repository was queried for individuals diagnosed with carotid artery stenosis between October 1, 2006, and September 30, 2010. A hierarchical multivariable model evaluated the association of the treatment system (fee-for-service physicians in the private sector vs salary-based military physicians) with the odds of procedural intervention (carotid endarterectomy or carotid artery stenting) compared with medical management. Subanalysis was performed by symptom status at the time of presentation. The association of treatment system and of management strategy with clinical outcomes, including stroke and death, was also evaluated. Data analysis was conducted from August 15, 2015, to August 2, 2016. The odds of procedural intervention based on treatment system was the primary outcome used to indicate the presence and effect of provider-induced demand. Of 10 579 individuals with a diagnosis of carotid artery stenosis (4615 women and 5964 men; mean [SD] age, 65.6 [11.4] years), 1307 (12.4%) underwent at least 1 procedure. After adjusting for demographic and clinical factors, the odds of undergoing procedural management were significantly higher for patients in the fee-for-service system compared with those in the salary-based setting (odds ratio, 1.629; 95% CI, 1.285-2.063; P < .001). This finding remained true when patients were stratified by symptom status at presentation (symptomatic: odds ratio, 2.074; 95% CI, 1.302-3.303; P = .002; and asymptomatic: odds ratio, 1.534; 95% CI, 1.186-1.984; P = .001). Individuals treated in a fee-for-service system were significantly more likely to undergo procedural management for carotid stenosis compared with those in the salary-based setting. These findings remained consistent for individuals with and without symptomatic disease.
Lansley, J A; Tucker, W; Eriksen, M R; Riordan-Eva, P; Connor, S E J
2017-09-01
Pulsatile tinnitus is experienced by most patients with idiopathic intracranial hypertension. The pathophysiology remains uncertain; however, transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence have been proposed as potential etiologies. We aimed to determine whether the prevalence of transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence was increased in patients with idiopathic intracranial hypertension and pulsatile tinnitus relative to those without pulsatile tinnitus and a control group. CT vascular studies of patients with idiopathic intracranial hypertension with pulsatile tinnitus ( n = 42), without pulsatile tinnitus ( n = 37), and controls ( n = 75) were independently reviewed for the presence of severe transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence according to published criteria. The prevalence of transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence in patients with idiopathic intracranial hypertension with pulsatile tinnitus was compared with that in the nonpulsatile tinnitus idiopathic intracranial hypertension group and the control group. Further comparisons included differing degrees of transverse sinus stenosis (50% and 75%), laterality of transverse sinus stenosis/sigmoid sinus diverticulum/dehiscence, and ipsilateral transverse sinus stenosis combined with sigmoid sinus diverticulum/dehiscence. Severe bilateral transverse sinus stenoses were more frequent in patients with idiopathic intracranial hypertension than in controls ( P < .001), but there was no significant association between transverse sinus stenosis and pulsatile tinnitus within the idiopathic intracranial hypertension group. Sigmoid sinus dehiscence (right- or left-sided) was also more common in patients with idiopathic intracranial hypertension compared with controls ( P = .01), but there was no significant association with pulsatile tinnitus within the idiopathic intracranial hypertension group. While our data corroborate previous studies demonstrating increased prevalence of sigmoid sinus diverticulum/dehiscence and transverse sinus stenosis in idiopathic intracranial hypertension, we did not establish an increased prevalence in patients with idiopathic intracranial hypertension with pulsatile tinnitus compared with those without. It is therefore unlikely that these entities represent a direct structural correlate of pulsatile tinnitus in patients with idiopathic intracranial hypertension. © 2017 by American Journal of Neuroradiology.
Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N; Zarogoulidis, Paul; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos
2012-11-01
Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2(nd) patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are associated with minimal granulation. In benign post-tracheostomy stenosis silicone stenting appeared safe and effective in re-stenosis after surgery and multiple bronchoscopic interventions, and in long stenosis, involving the lower posterior subglottic larynx in the presence on inflammation and poor neurological status.
Pardo González, Laura; Ruiz Ortiz, Martin; Delgado, Mónica; Mesa, Dolores; Villalba, Rafael; Rodriguez, Sara; Hidalgo, Francisco J; Alados, Pedro; Casares, Jaime; Suarez de Lezo, Jose
2017-04-01
The Ross procedure is used in the treatment of selected patients with aortic valve disease. Pulmonary graft stenosis can appear in the long-term follow-up after the Ross intervention, but the factors involved and its clinical implications are not fully known. To describe the incidence, clinical impact and predictors of homograft stenosis and reintervention after the Ross procedure in a prospective series in a tertiary referral hospital. From 1997 to 2009, 107 patients underwent the Ross procedure (mean age: 30±11 years; 69% men; 21 aged<18 years), and were followed for echocardiographic homograft stenosis (peak gradient>36mmHg) and surgical or percutaneous homograft reintervention. After 15 years of follow-up (median: 11 years), echocardiographic and clinical data were available in 91 (85%) and 104 (98%) patients, respectively: 26/91 (29%) patients developed homograft stenosis; 10/104 (10%) patients underwent 13 homograft reintervention procedures (three patients underwent surgical replacement, three received a percutaneous pulmonary valve and one needed stent implantation). The other three patients underwent two consecutive procedures in follow-up; one died because of a procedure-related myocardial infarction. Rates of survival free from homograft stenosis and reintervention at 1, 5 and 10 years were 96%, 82% and 75% and 99%, 94% and 91%, respectively. Paediatric patients had worse survival free from homograft stenosis (hazard ratio [HR] 3.50, 95% confidence interval [CI]: 1.56-7.90; P=0.002), although there were no significant differences regarding reintervention (HR: 2.01, 95% CI: 0.52-7.78; P=0.31). Younger age of homograft donor was also a stenosis predictor (HR: 0.97, 95% CI: 0.94-0.99; P=0.046). The probabilities of homograft stenosis and reintervention 10 years after the Ross procedure were 29% and 10%, respectively; only one patient had a reintervention-related death. Younger donor and recipient age were associated with a higher rate of stenosis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N.; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos
2012-01-01
Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2nd patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are associated with minimal granulation. In benign post-tracheostomy stenosis silicone stenting appeared safe and effective in re-stenosis after surgery and multiple bronchoscopic interventions, and in long stenosis, involving the lower posterior subglottic larynx in the presence on inflammation and poor neurological status. PMID:23304439
Dulohery, Kate; Papavdi, Asteria; Michalodimitrakis, Manolis; Kranioti, Elena F
2012-11-01
Coronary artery atherosclerosis is a hugely prevalent condition in the Western World and is often encountered during autopsy. Atherosclerotic plaques can cause luminal stenosis: which, if over a significant level (75%), is said to contribute to cause of death. Estimation of stenosis can be macroscopically performed by the forensic pathologists at the time of autopsy or by microscopic examination. This study compares macroscopic estimation with quantitative microscopic image analysis with a particular focus on the assessment of significant stenosis (>75%). A total of 131 individuals were analysed. The sample consists of an atherosclerotic group (n=122) and a control group (n=9). The results of the two methods were significantly different from each other (p=0.001) and the macroscopic method gave a greater percentage stenosis by an average of 3.5%. Also, histological examination of coronary artery stenosis yielded a difference in significant stenosis in 11.5% of cases. The differences were attributed to either histological quantitative image analysis underestimation; gross examination overestimation; or, a combination of both. The underestimation may have come from tissue shrinkage during tissue processing for histological specimen. The overestimation from the macroscopic assessment can be attributed to the lumen shape, to the examiner observer error or to a possible bias to diagnose coronary disease when no other cause of death is apparent. The results indicate that the macroscopic estimation is open to more biases and that histological quantitative image analysis only gives a precise assessment of stenosis ex vivo. Once tissue shrinkage, if any, is accounted for then histological quantitative image analysis will yield a more accurate assessment of in vivo stenosis. It may then be considered a complementary tool for the examination of coronary stenosis. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Transverse Sinus Stenosis in Adult Patients With Chiari Malformation Type I
Saindane, Amit M.; Bruce, Beau B.; Desai, Nilesh K.; Roller, Lauren A.; Newman, Nancy J.; Biousse, Valérie
2014-01-01
OBJECTIVE Transverse sinus stenosis is an imaging finding very highly associated with elevated intracranial pressure (ICP). Patients with the Chiari I malformation may potentially have elevated ICP due to impairment of CSF flow at the foramen magnum. This study evaluated whether patients with Chiari I malformation have transverse sinus stenosis and other imaging findings indicative of elevated ICP. MATERIALS AND METHODS Thirty patients with Chiari I malformation treated surgically and 76 control subjects were identified retrospectively. All control subjects and all patients with Chiari I malformation (preoperatively) underwent standardized contrast-enhanced brain MRI including a contrast-enhanced 3D T1-weighted sequence from which curved reformats of the transverse sinuses were generated. Two different readers blinded to the diagnosis then independently evaluated these curved reformats for severity of transverse sinus stenosis. Orbital and skull-base findings previously described in association with elevated ICP were also evaluated. Frequency of MRI findings between the two groups was compared. RESULTS Patients with Chiari I malformation had significantly greater frequency of unilateral or bilateral transverse sinus stenosis than did control subjects (p < 0.001). There was complete interreader agreement on presence or absence of transverse sinus stenosis by patient (κ = 1.0 [95% CI, 0.89–1.0]). Logistic regression analysis controlling for age, sex, and body mass index found that transverse sinus stenosis significantly predicted Chiari I malformation versus control status (odds ratio, 11.2 [95% CI, 2.1–59.0]; p = 0.004) but that no other features were significantly associated with the Chiari I malformation. Patients with Chiari I malformation who had transverse sinus stenosis had significantly greater pituitary flattening than did those without transverse sinus stenosis (p = 0.02). CONCLUSION Patients with Chiari I malformation have higher likelihood of trans-verse sinus stenosis, which may reflect associated elevated ICP. PMID:25247957
Hart, Michael A; Shroff, Gautam R
2017-02-17
Infective endocarditis rarely causes mitral valve stenosis. When present, it has the potential to cause severe hemodynamic decompensation and death. There are only 15 reported cases in the literature of mitral prosthetic valve bacterial endocarditis causing stenosis by obstruction. This case is even more unusual due to the mechanism by which functional mitral stenosis occurred. We report a case of a 23-year-old white woman with a history of intravenous drug abuse who presented with acute heart failure. Transthoracic echocardiography failed to show valvular vegetation, but high clinical suspicion led to transesophageal imaging that demonstrated infiltrative prosthetic valve endocarditis causing severe mitral stenosis. Despite extensive efforts from a multidisciplinary team, she died as a result of her critical illness. The discussion of this case highlights endocarditis physiology, the notable absence of stenosis in modified Duke criteria, and the utility of transesophageal echocardiography in clinching a diagnosis. It advances our knowledge of how endocarditis manifests, and serves as a valuable lesson for clinicians treating similar patients who present with stenosis but no regurgitation on transthoracic imaging, as a decision to forego a transesophageal echocardiography could cause this serious complication of endocarditis to be missed.
The "Polar Light Sign" is a useful tool to detect discrete membranous supravalvular mitral stenosis.
Hertwig, Christine; Haas, Nikolaus A; Habash, Sheeraz; Hanslik, Andreas; Kececioglu, Deniz; Sandica, Eugen; Laser, Kai-Thorsten
2015-02-01
Mitral valve stenosis caused by a discrete supravalvular membrane is a rare congenital malformation haemodynamically leading to significant mitral valve stenosis. When the supravalvular mitral stenosis consists of a discrete supravalvular membrane adherent to the mitral valve, it is usually not clearly detectable by routine echocardiography. We report about the typical echocardiographic finding in three young patients with this rare form of a discrete membranous supravalvular stenosis caused by a membrane adherent to the mitral valve. These cases present a typical echocardiographic feature in colour Doppler generated by the pathognomonic supramitral flow acceleration. Whereas typical supravalvular mitral stenosis caused by cor triatriatum or a clearly visible supravalvular ring is easily detectable by echocardiography, a discrete supravalvular membrane adjacent to the mitral valve leaflets resembling valvular mitral stenosis is difficult to differentiate by routine echocardiography. In our opinion, this colour phenomenon does resemble the visual impression of polar lights in the northern hemisphere; owing to its typical appearance, it may therefore be named as "Polar Light Sign". This phenomenon may help to detect this anatomical entity by echocardiography in time and therefore improve the prognosis for repair.
Balloon dilatation of nasopharyngeal stenosis in a dog.
Berent, Allyson C; Kinns, Jennifer; Weisse, Chick
2006-08-01
A dog was examined because of a 6-month history of upper airway stridor that began after postoperative regurgitation of gastric contents. Constant stridor was evident during inspiration and expiration, although it was worse during inspiration. The stridor was no longer evident when the dog's mouth was manually held open. Computed tomography, rhinoscopy, and fluoroscopy were used to confirm a diagnosis of nasopharyngeal stenosis. The dog was anesthetized, and balloon dilatation of the stenosis was performed. Prednisone was prescribed for 4 weeks after the procedure to decrease fibrous tissue formation. Although the dog was initially improved, signs recurred 3.5 weeks later, and balloon dilatation was repeated. This time, however, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Two months later, although the dog did not have clinical signs of stridor, a third dilatation procedure was performed because mild stenosis was seen on follow-up computed tomographic images; again, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Three and 6 months after the third dilatation procedure, the dog reportedly was clinically normal. Findings suggest that balloon dilatation may be an effective treatment for nasopharyngeal stenosis in dogs.
64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access.
Wasinrat, Jitladda; Siriapisith, Thanongchai; Thamtorawat, Somrach; Tongdee, Trongtum
2011-01-01
To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant (<50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmadi, Ramazan-Ali; Schillinger, Martin; Haumer, Markus
Endarterectomy is currently the preferred treatment for severe carotid stenosis. The technique of eversion endarterectomy allows correction of severe vessel elongation and kinking. The latter is generally believed to be a relative contraindication for endovascular stent placement. We report successful percutaneous transluminal angioplasty and stenting of a left internal carotid artery with high-grade stenosis and severe kinking which was not amenable to endarterectomy because of the distal location of the stenosis. Advanced stent technology with flexible materials makes endovascular treatment of carotid stenosis feasible even in cases of kinking.
Yoshikawa, Yukihiro; Yoshikawa, Masato; Kawabata, Ryohei; Yoshida, Yuta; Kawada, Masahiro; Yasuyama, Akinobu; Watase, Chikashi; Koga, Chikato; Hitora, Toshiki; Murakami, Masahiro; Hirota, Masaki; Ikenaga, Masakazu; Shimizu, Junzo; Hasegawa, Junichi
2015-11-01
A 68-year-old man underwent esophagectomy for early esophageal cancer. Postoperative upper gastrointestinal series and esophagogastroduodenoscopy showed gastric tube stenosis. To improve passage, a removable self-expandable metallic stent (SEMS) was placed across the stenotic lesion. Two weeks later, the stent was removed, and passage through the gastric tube improved. The patient has no symptoms of stenosis. A removable SEMS could be an option for the treatment of gastric tube stenosis after esophagectomy.
Levy, Franck; Iacuzio, Laura; Civaia, Filippo; Rusek, Stephane; Dommerc, Carine; Hugues, Nicolas; Alexandrescu, Clara; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles
2016-11-01
Recently, 1.5-Tesla cardiac magnetic resonance imaging (CMR) was reported to provide a reliable alternative to transthoracic echocardiography (TTE) for the quantification of aortic stenosis (AS) severity. Few data are available using higher magnetic field strength MRI systems in this context. To evaluate the feasibility and reproducibility of the assessment of aortic valve area (AVA) using 3-Tesla CMR in routine clinical practice, and to assess concordance between TTE and CMR for the estimation of AS severity. Ninety-one consecutive patients (60 men; mean age 74±10years) with known AS documented by TTE were included prospectively in the study. All patients underwent comprehensive TTE and CMR examination, including AVA estimation using the TTE continuity equation (0.81±0.18cm 2 ), direct CMR planimetry (CMRp) (0.90±0.22cm 2 ) and CMR using Hakki's formula (CMRhk), a simplified Gorlin formula (0.70±0.19cm 2 ). Although significant agreement with TTE was found for CMRp (r=0.72) and CMRhk (r=0.66), CMRp slightly overestimated (bias=0.11±0.18cm 2 ) and CMRhk slightly underestimated (bias=-0.11±0.17cm 2 ) AVA compared with TTE. Inter- and intraobserver reproducibilities of CMR measurements were excellent (r=0.72 and r=0.74 for CMRp and r=0.88 and r=0.92 for peak aortic velocity, respectively). 3-Tesla CMR is a feasible, radiation-free, reproducible imaging modality for the estimation of severity of AS in routine practice, knowing that CMRp tends to overestimate AVA and CMRhk to underestimate AVA compared with TTE. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atsumi, Kazushige; Shioyama, Yoshiyuki, E-mail: shioyama@radiol.med.kyushu-u.ac.jp; Arimura, Hidetaka
Purpose: To determine clinical factors for predicting the frequency and severity of esophageal stenosis associated with tumor regression in radiotherapy for esophageal cancer. Methods and Materials: The study group consisted of 109 patients with esophageal cancer of T1-4 and Stage I-III who were treated with definitive radiotherapy and achieved a complete response of their primary lesion at Kyushu University Hospital between January 1998 and December 2007. Esophageal stenosis was evaluated using esophagographic images within 3 months after completion of radiotherapy. We investigated the correlation between esophageal stenosis after radiotherapy and each of the clinical factors with regard to tumors andmore » therapy. For validation of the correlative factors for esophageal stenosis, an artificial neural network was used to predict the esophageal stenotic ratio. Results: Esophageal stenosis tended to be more severe and more frequent in T3-4 cases than in T1-2 cases. Esophageal stenosis in cases with full circumference involvement tended to be more severe and more frequent than that in cases without full circumference involvement. Increases in wall thickness tended to be associated with increases in esophageal stenosis severity and frequency. In the multivariate analysis, T stage, extent of involved circumference, and wall thickness of the tumor region were significantly correlated to esophageal stenosis (p = 0.031, p < 0.0001, and p = 0.0011, respectively). The esophageal stenotic ratio predicted by the artificial neural network, which learned these three factors, was significantly correlated to the actual observed stenotic ratio, with a correlation coefficient of 0.864 (p < 0.001). Conclusion: Our study suggested that T stage, extent of involved circumference, and esophageal wall thickness of the tumor region were useful to predict the frequency and severity of esophageal stenosis associated with tumor regression in radiotherapy for esophageal cancer.« less
Internal Carotid Artery Stenosis and Collateral Recruitment in Stroke Patients.
Dankbaar, Jan W; Kerckhoffs, Kelly G P; Horsch, Alexander D; van der Schaaf, Irene C; Kappelle, L Jaap; Velthuis, Birgitta K
2017-04-24
Leptomeningeal collaterals improve outcome in stroke patients. There is great individual variability in their extent. Internal carotid artery (ICA) stenosis may lead to more extensive recruitment of leptomeningeal collaterals. The purpose of this study was to evaluate the association of pre-existing ICA stenosis with leptomeningeal collateral filling visualized with computed tomography perfusion (CTP). From a prospective acute ischemic stroke cohort, patients were included with an M1 middle cerebral artery (MCA) occlusion and absent ipsilateral, extracranial ICA occlusion. ICA stenosis was determined on admission CT angiography (CTA). Leptomeningeal collaterals were graded as good (>50%) or poor (≤50%) collateral filling in the affected MCA territory on CTP-derived vessel images of the admission scan. The association between ipsilateral ICA stenosis ≥70% and extent of collateral filling was analyzed using logistic regression. In a multivariable analysis the odds ratio (OR) of ICA stenosis ≥70% was adjusted for complete circle of Willis, gender and age. We included 188 patients in our analyses, 50 (26.6%) patients were classified as having poor collateral filling and 138 (73.4%) as good. Of the patients 4 with poor collateral filling had an ICA stenosis ≥70% and 14 with good collateral filling. Unadjusted and adjusted ORs of ICA stenosis ≥70% for good collateral filling were 1.30 (0.41-4.15) and 2.67 (0.81-8.77), respectively. Patients with poor collateral filling had a significantly worse outcome (90-day modified Rankin scale 3-6; 80% versus 52%, p = 0.001). No association was found between pre-existing ICA stenosis and extent of CTP derived collateral filling in patients with an M1 occlusion.
Meyer, Mathias; Henzler, Thomas; Fink, Christian; Vliegenthart, Rozemarijn; Barraza, J Michael; Nance, John W; Apfaltrer, Paul; Schoenberg, Stefan O; Wasser, Klaus
2012-11-01
To investigate the prevalence of significant coronary artery stenosis on coronary computed tomography angiography (cCTA) in symptomatic Caucasian patients with an intermediate risk score at different levels of coronary artery calcification (CAC). In total, 383 consecutive symptomatic Caucasian patients (147 females, 60 ± 13 years) with an intermediate risk score underwent nonenhanced CT for CAC scoring immediately before contrast-enhanced cCTA on a dual-source CT scanner. Additionally clinically indicated invasive coronary angiography (ICA) was performed in 90 patients. The prevalence of significant coronary artery stenosis (>50%) on cCTA and ICA was correlated at different CAC score levels. Of 121 patients with a zero CAC score, none had significant coronary artery stenosis on cCTA or ICA. Coronary CTA diagnosed in 54 of 70 patients with high CAC score (>400), a significant stenosis. Subsequent ICA confirmed significant stenosis in 30 of 32 patients. Sensitivity and a negative predictive value of CAC score ruling out significant stenosis on cCTA were 100% and 100%, respectively, using cutoff value of zero and specificity and positive predictive value to predict significant stenosis on cCTA were 79% and 51%, respectively, using a cutoff value of >400. Significant coronary artery stenosis is extremely unlikely, with an estimated risk of 4 in 1000 patients in symptomatic Caucasian patients with an intermediate risk score and negative CAC score. To reduce radiation exposure, radiation-free tests should be considered for differential diagnosis of chest pain in these patients. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mann, S.J.; Pickering, T.G.; Sos, T.A.
The purpose of this study was to determine the sensitivity, specificity, and clinical usefulness of renography performed in combination with captopril administration (captopril renography) in diagnosing renal artery stenosis. Fifty-five patients with suspected renal artery stenosis underwent renography prior to performance of renal angiography. Renography was performed on two consecutive days using technetium-99m-diethylenetiamine pentaacetic acid (DTPA) as an index of glomerular filtration rate and iodine-131-orthoiodohippurate (OIH) as an index of renal blood flow. Captopril (25 mg orally, crushed) was administered 1 hour before the second study. Renal artery stenosis was defined as a stenosis exceeding 70%. Renographic criteria were thenmore » established, retrospectively, to differentiate renal artery stenosis from essential hypertension based on (1) asymmetry of function and (2) the presence of captopril-induced changes. Renal artery stenosis was detected in 35 of 55 patients (21 with unilateral and 14 with bilateral stenosis). Three criteria were established for diagnosing renal artery stenosis: (1) a percent uptake of DTPA by the affected kidney of less than 40% of the combined bilateral uptake, (2) a delayed time to peak uptake of DTPA, which was more than 5 minutes longer in the affected kidney than in the contralateral kidney, (3) a delayed excretion of DTPA, with retention at 15 minutes, as a fraction of peak activity, more than 20% greater than in the contralateral kidney. The presence of one or more of these criteria was diagnostic of renal artery stenosis, with a sensitivity and specificity of 71% and 75%, respectively before captopril administration, and 94% and 95% after captopril administration. Lesser degrees of asymmetry (i.e., uptake of 40% to 50%) had very poor diagnostic specificity.« less
Assessment of insulin-like growth factor-1 (IGF-I) level in patients with rheumatic mitral stenosis.
Deveci, Onur S; Yavuz, Bunyamin; Sen, Omer; Deniz, Ali; Ozkan, Selcuk; Dal, Kursat; Ata, Naim; Baser, Salih; Akin, Kadir O; Kucukazman, Metin; Beyan, Esin; Ertugrul, Derun T
2015-03-01
Insulin-like growth factor-1 may serve some regulatory function in the immune system. Rheumatic mitral stenosis is related to autoimmune heart valve damage after streptococcal infection. The aim of this study was to assess the level of insulin-like growth factor-1 and its correlation with the Wilkins score in patients with rheumatic mitral stenosis. A total of 65 patients with rheumatic mitral stenosis and 62 age- and sex-matched control subjects were enrolled in this study. All subjects underwent transthoracic echocardiography. The mitral valve area and Wilkins score were evaluated for all patients. Biochemical parameters and serum insulin-like growth factor-1 levels were measured. Demographic data were similar in the rheumatic mitral stenosis and control groups. The mean mitral valve area was 1.6±0.4 cm2 in the rheumatic mitral stenosis group. The level of insulin-like growth factor-1 was significantly higher in the rheumatic mitral stenosis group than in the control group (104 (55.6-267) versus 79.1 (23.0-244.0) ng/ml; p=0.039). There was a significant moderate positive correlation between insulin-like growth factor-1 and thickening of leaflets score of Wilkins (r=0.541, p<0.001). The present study demonstrated that serum insulin-like growth factor-1 levels were significantly higher in the rheumatic mitral stenosis group compared with control subjects and that insulin-like growth factor-1 level was also correlated with the Wilkins score. It can be suggested that there may be a link between insulin-like growth factor-1 level and immune pathogenesis of rheumatic mitral stenosis.
Sarikaya, B; Lohman, B; Mckinney, A M; Gadani, S; Irfan, M; Lucato, L
2012-01-01
Objectives Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods 50 patients (aged 41–82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered “significant”. Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm3 were utilised and Pearson'S correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate–strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm3 was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a “score” that could predict high grade stenosis. PMID:21896662
Kim, Jae Woon; Lee, Jae Kyo
2012-01-01
Objective To investigate the role of lumbosacral radiculography using 3-dimentional (3D) magnetic resonance (MR) rendering for diagnostic information of symptomatic extraforaminal stenosis in lumbosacral transitional vertebra. Materials and Methods The study population consisted of 18 patients with symptomatic (n = 10) and asymptomatic extraforaminal stenosis (n = 8) in lumbosacral transitional vertebra. Each patient underwent 3D coronal fast-field echo sequences with selective water excitation using the principles of the selective excitation technique (Proset imaging). Morphologic changes of the L5 nerve roots at the symptomatic and asymptomatic extraforaminal stenosis were evaluated on 3D MR rendered images of the lumbosacral spine. Results Ten cases with symptomatic extraforaminal stenosis showed hyperplasia and degenerative osteophytes of the sacral ala and/or osteophytes at the lateral margin of the L5 body. On 3D MR lumbosacral radiculography, indentation of the L5 nerve roots was found in two cases, while swelling of the nerve roots was seen in eight cases at the exiting nerve root. Eight cases with asymptomatic extraforaminal stenosis showed hyperplasia and degenerative osteophytes of the sacral ala and/or osteophytes at the lateral margin of the L5 body. Based on 3D MR lumbosacral radiculography, indentation or swelling of the L5 nerve roots was not found in any cases with asymptomatic extraforaminal stenosis. Conclusion Results from 3D MR lumbosacral radiculography Indicate the indentation or swelling of the L5 nerve root in symptomatic extraforaminal stenosis. Based on these findings, 3D MR radiculography may be helpful in the diagnosis of the symptomatic extraforaminal stenosis with lumbosacral transitional vertebra. PMID:22778561
Systematic Review of Guidelines for the Management of Asymptomatic and Symptomatic Carotid Stenosis.
Abbott, Anne L; Paraskevas, Kosmas I; Kakkos, Stavros K; Golledge, Jonathan; Eckstein, Hans-Henning; Diaz-Sandoval, Larry J; Cao, Longxing; Fu, Qiang; Wijeratne, Tissa; Leung, Thomas W; Montero-Baker, Miguel; Lee, Byung-Chul; Pircher, Sabine; Bosch, Marije; Dennekamp, Martine; Ringleb, Peter
2015-11-01
We systematically compared and appraised contemporary guidelines on management of asymptomatic and symptomatic carotid artery stenosis. We systematically searched for guideline recommendations on carotid endarterectomy (CEA) or carotid angioplasty/stenting (CAS) published in any language between January 1, 2008, and January 28, 2015. Only the latest guideline per writing group was selected. Each guideline was analyzed independently by 2 to 6 authors to determine clinical scenarios covered, recommendations given, and scientific evidence used. Thirty-four eligible guidelines were identified from 23 different regions/countries in 6 languages. Of 28 guidelines with asymptomatic carotid artery stenosis procedural recommendations, 24 (86%) endorsed CEA (recommended it should or may be provided) for ≈50% to 99% average-surgical-risk asymptomatic carotid artery stenosis, 17 (61%) endorsed CAS, 8 (29%) opposed CAS, and 1 (4%) endorsed medical treatment alone. For asymptomatic carotid artery stenosis patients considered high-CEA-risk because of comorbidities, vascular anatomy, or undefined reasons, CAS was endorsed in 13 guidelines (46%). Thirty-one of 33 guidelines (94%) with symptomatic carotid artery stenosis procedural recommendations endorsed CEA for patients with ≈50% to 99% average-CEA-risk symptomatic carotid artery stenosis, 19 (58%) endorsed CAS and 9 (27%) opposed CAS. For high-CEA-risk symptomatic carotid artery stenosis because of comorbidities, vascular anatomy, or undefined reasons, CAS was endorsed in 27 guidelines (82%). Guideline procedural recommendations were based only on results of trials in which patients were randomized 12 to 34 years ago, rarely reflected medical treatment improvements and often understated potential CAS hazards. Qualifying terminology summarizing recommendations or evidence lacked standardization, impeding guideline interpretation, and comparison. This systematic review has identified many opportunities to modernize and otherwise improve carotid stenosis management guidelines. © 2015 American Heart Association, Inc.
[Cervical tracheal resection with primary anastomosis for benign tracheal stricture in adult].
Ye, Jin; Hu, Yan-Ming; Liu, Hui; Li, Jing-Jia; Wang, Zhi-Yuan; Li, Yuan
2013-07-01
To introduce the outcomes of tracheal resection with primary end to end anastomosis for benign cervical tracheal stenosis, and to discuss the strategy for prevention of surgical complications. A retrospective analysis was performed in 12 patients diagnosed as benign cervical tracheal stenosis from October 2009 to June 2012. Laryngo-tracheal endoscopic examination and computed tomography (CT) were used to assess the degree of stenosis, the grade of inflammation and edema of the subglottis and trachea, and the extent of stenosis and the remaining linear amount of normal airway. The Meyer and Cotton grading system was used to categorise the clinical severity of the stenoses. All patients underwent tracheal resection with primary end to end anastomosis. The length of cervical tracheal stenosis ranged from 2.3 to 4.1 cm. Grade II stenosis was present in three patients, Grade III stenosis was present in seven patients and grade IV stenosis in two patients. Successful extubation was achieved in all 12 cases. After surgery, temporary hoarseness occurred in 1 patient (8.3%); unilateral pulmonary atelectasis with pleural effusion occurred in 1 patient (8.3%); subcutaneous emphysema with infection occurred in 1 patient (8.3%); mild dysphagia occurred in 3 patients (25.0%); a slight deepening of the tone of voice occurred in 5 patients (41.7%), granulation tissue growth near the suture occurred in 3 patients (25.0%), and suture dehiscence did not occur in any patient. The follow-up period ranged from 6 months to 38 months, no patient developed restenosis. It presents a high success rate and good functional result of tracheal resection with primary end-to-end anastomosis. Therefore, it is an effective and reliable approach for the management of benign cervical tracheal stenosis. To avoid complications, the preoperative assessment, patients selection and postoperative management should be emphasized.
Liu, Jing-zheng; Zhong, Yun-shi; Xu, Mei-dong; Chen, Wei-feng; Zhou, Ping-hong; Yao, Li-qing
2013-12-01
To investigate the efficacy and safety of membrane-covered self-expanding metal stent in the treatment of high-positioned esophageal diseases, including esophageal stenosis, esophagotracheal fistula and anastomotic stricture. Clinical data of 84 patients who underwent stenting in our center from May 2005 to July 2013 were retrospectively analyzed. Of 84 patients, 31 were diagnosed as esophageal malignant stenosis, 2 compression stenosis, 10 radiation stenosis, 4 recurrent malignant stenosis, 27 anastomotic stricture, 1 esophageal stenosis after endoscopic submucosal dissection (ESD), 7 esophageal-tracheal fistula, 1 esophageal-mediastinal fistula, and 1 remnant stomach fistula. Distance from stenosis or fistula to central incisor was 15-20 cm in 48 cases, and more than 20 cm in 36 cases. All the patients were treated by 16 mm membrane-covered self-expanding metal stents. Main clinical manifestations and complications were evaluated. A total of 100 stents were placed in 84 patients,with a success rate of 100%. There were no complications such as perforation and bleeding during operation. Dysphagia and cough were improved quickly with a success rate of 100%. After the placement of stents, the incidence of complication was 6.0% (5/84), of which 2 cases were severe retrosternal pain, 1 was tracheal collapse, and 2 were stent displacement. Seventy-six patients (90.5%) received complete follow-up of 1 to 36 months (mean 15 months). Re-stenosis occurred in 4 cases, new esophageal-tracheal fistula in 2 cases. Among these 6 cases, 5 cases underwent successfully stent placement once again, and another one case received Savary bougie and Argon-ion coagulation with good efficacy. Endoscopic membrane-covered self-expanding metal stent placement is effective and safe for the relieve of dysphagia symptoms and the sealing of esophagotracheal fistula.
Slovut, David P; Romero, Javier M; Hannon, Kathleen M; Dick, James; Jaff, Michael R
2010-01-01
Severe stenosis of the common carotid artery (CCA), while uncommon, is associated with increased risk of transient ischemic attack and stroke. To date, no validated duplex ultrasound criteria have been established for grading the severity of CCA stenosis. The goal of this study was to use receiver-operating curve (ROC) analysis with computed tomographic angiography as the reference standard to establish duplex ultrasound criteria for diagnosing >or=50% CCA stenosis. The study cohort included 64 patients (42 men, 22 women) with a mean age of 65 +/- 12 years (range, 16-89 years) who had CCA peak systolic velocity (PSV) >or=150 cm/sec and underwent computed tomographic angiography (CTA) of the cervical and intracerebral vessels within 1 month of the duplex examination. One study was excluded because the CTA was technically inadequate, whereas another was excluded because the patient underwent bilateral CCA stenting. The CCA ipsilateral to any of the following was excluded from the analysis: innominate artery occlusion (n = 1), previous stenting of the ICA or CCA (n = 7), carotid endarterectomy (n = 1), or carotid-to-carotid bypass (n = 1). Thus, the data set included 62 patients and 115 vessels. Bland-Altman analysis was used to examine the agreement between two measures of luminal reduction measured by CTA: percent diameter stenosis and percent area stenosis. Receiver operating characteristic (ROC) analysis was used to determine optimal PSV and EDV thresholds for diagnosing >or=50% CCA stenosis. Severity of CCA stenosis was <50% in 76 vessels, 50%-59% in eight, 60%-69% in eight, 70%-79% in nine, 80%-89% in three, 90%-99% in five, and occluded in six. Duplex ultrasonography identified six of six (100%) patients with 100% CCA occlusion by CTA. Bland-Altman analysis showed poor agreement between percent stenosis determined by vessel diameter compared with percent stenosis determined by reduction in lumen area. Therefore, subsequent analysis was performed using percent stenosis by area. ROC analysis of different PSV thresholds for detecting stenosis >or=50% showed that >182 cm/sec was the most accurate with a sensitivity of 64% and specificity of 88% (P < .0001). Sensitivity, specificity, and accuracy of carotid duplex were higher when the stenosis was located in the mid or distal aspects of the CCA (sensitivity 76%, specificity 89%, area under curve 0.84, P < .001) than in the intrathoracic and proximal segment of the artery (P = NS). ROC analysis of different EDV thresholds for detecting CCA stenosis >or=50% showed that >30 cm/sec was the most accurate with a sensitivity of 54% and a specificity of 74% (P < .0239). Duplex ultrasonography is highly sensitive, specific, and accurate for detecting CCA lesions in the mid and distal CCA. Use of peak systolic velocity may lead to improved detection of CCA disease and initiation of appropriate therapy to reduce the risk of stroke. Copyright 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
[Ergotamine-induced rectal stenosis in a patient with long-term migraine].
Machnig, T; May, A; Steininger, H; von Streitberg, U; Hahn, E G; Ell, C
1993-07-01
A 36 year old woman was admitted to our hospital for treatment of a high-grade rectal stenosis of unknown origin. She had a history of migraine going back 10 years. On intensive questioning she admitted using up to 5 ergotamine-containing suppositories a day. On the basis of history and clinical investigations the rectal stenosis must be connected with the abuse of ergotamine-containing suppositories. This case demonstrates that patients with an unexplained rectal syndrome should be asked for analgetics-containing suppositories specifically. Only discontinuation of treatment in time can preserve the patient from development of a rectal stenosis. In case of a rectal stenosis surgical treatment can be avoided by means of endoscopic controlled dilatation.
Treibel, Thomas A.; Bandula, Steve; Fontana, Marianna; White, Steven K.; Gilbertson, Janet A.; Herrey, Anna S.; Gillmore, Julian D.; Punwani, Shonit; Hawkins, Philip N.; Taylor, Stuart A.; Moon, James C.
2015-01-01
Background Cardiac involvement determines outcome in patients with systemic amyloidosis. There is major unmet need for quantification of cardiac amyloid burden, which is currently only met in part through semi-quantitative bone scintigraphy or Cardiovascular Magnetic Resonance (CMR), which measures ECVCMR. Other accessible tests are needed. Objectives To develop cardiac computed tomography to diagnose and quantify cardiac amyloidosis by measuring the myocardial Extracellular Volume, ECVCT. Methods Twenty-six patients (21 male, 64 ± 14 years) with a biopsy-proven systemic amyloidosis (ATTR n = 18; AL n = 8) were compared with twenty-seven patients (19 male, 68 ± 8 years) with severe aortic stenosis (AS). All patients had undergone echocardiography, bone scintigraphy, NT-pro-BNP measurement and EQ-CMR. Dynamic Equilibrium CT (DynEQ-CT) was performed using a prospectively gated cardiac scan prior to and after (5 and 15 minutes) a standard Iodixanol (1 ml/kg) bolus to measure ECVCT. ECVCT was compared to the reference ECVCMR and conventional amyloid measures: bone scintigraphy and clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area). Results ECVCT and ECVCMR results were well correlated (r2 = 0.85 vs r2 = 0.74 for 5 and 15 minutes post bolus respectively). ECVCT was higher in amyloidosis than AS (0.54 ± 0.11 vs 0.28 ± 0.04, p<0.001) with no overlap. ECVCT tracked clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area), and bone scintigraphy amyloid burden (p<0.001). Conclusion Dynamic Equilibrium CT, a 5 minute contrast-enhanced gated cardiac CT, has potential for non-invasive diagnosis and quantification of cardiac amyloidosis. PMID:26209459
Donors with renal artery stenosis: fit to donate.
Reddy, Vemuru Sunil K; Guleria, Sandeep; Bora, Girdhar S
2012-05-01
Kidney donation from hypertensive donors is now an accepted norm in live related kidney transplantation. The use of hypertensive donors with renal artery stenosis due to atherosclerosis and fibromuscular dysplasia is still debated. The prime concern is about the deleterious effect of hypertension on the donor and the risk of recurrence of such lesions in the solitary kidney. Even as the response of atherosclerotic renal artery stenosis to revascularisation is unpredictable, there is an improvement in blood pressure following revascularisation of kidneys with fibro-muscular dysplasia. The first use of such kidney donors was reported in 1984 and, since then, there have been a few reports of successful use of kidneys from donors with renal artery stenosis. We report here two interesting cases of successful transplantation of kidneys from live related kidney donors with hypertension due to renal artery stenosis who became normotensive with good graft function in the recipient. We conclude that moderately hypertensive donors with renal artery stenosis are fit to donate.
Evidence for Management of Carotid Artery Stenosis
YOSHIDA, Kazumichi; MIYAMOTO, Susumu
2015-01-01
In this review, we presented the evidence concerning carotid artery stenosis treatment in symptomatic stenosis and asymptomatic stenosis separately, and discussed the future challenges. The validity of carotid endarterectomy (CEA) to treat moderate or greater degree of symptomatic carotid artery stenosis appears to be established. Due to the additional option of carotid artery stenting (CAS), it is necessary to comprehensively determine whether CEA or CAS is more appropriate for each individual patient. Moreover, since there are rapid advancements in devices for CAS and improvements in treatment outcomes, continual learning of the latest treatment method is essential. For asymptomatic stenosis, due to improvements in the outcomes with best medical treatment (BMT), it is essential to re-evaluate the use of invasive CEA/CAS. Continual verification of the latest randomized clinical trial that compares CEA, CAS, and BMT, and establishment of a diagnostic method that can accurately extract the group of patients who have the highest future risk of developing ischemia, are desired. PMID:25739437
Echocardiographic Assessment of Mantle Radiation Mitral Stenosis.
Bastiaenen, Rachel; Sneddon, James; Sharma, Rajan
2016-02-01
The long-term sequelae of mantle radiotherapy include lung disease and cardiac disorders. Dyspnea on exertion is a common complaint and can be due to one or more pathologies. We describe a case of mantle radiotherapy-induced mitral stenosis, characterized by aorto-mitral continuity calcification and absent commissural fusion which precludes balloon valvotomy. The latency period is long, and this patient presented 42 years after radiotherapy. Importantly, as previously described with radiation-induced valve disease, significant mitral stenosis developed 10 years after surgery for significant aortic stenosis. Two-dimensional and three-dimensional transthoracic and transesophageal echocardiography should be considered during assessment of symptomatic survivors of Hodgkin's disease where the index of suspicion for valvular stenosis increases over time. Given the natural history of mantle radiation valvular disease, a lower threshold for surgical intervention in radiation-induced mitral stenosis may need to be considered if cardiac surgery is planned for other reasons in order to avoid repeated sternotomy in patients with prior irradiation. © 2015, Wiley Periodicals, Inc.
Adlakha, Satjit; Reed, Grant; Brewster, Pamela; Kennedy, David; Burket, Mark W.; Colyer, William; Yu, Haifeng; Zhang, Dong; Shapiro, Joseph I.; Cooper, Christopher J.
2011-01-01
Summary Background and objectives Soluble CD40 ligand (sCD40L) is a marker of platelet activation; whether platelet activation occurs in the setting of renal artery stenosis and stenting is unknown. Additionally, the effect of embolic protection devices and glycoprotein IIb/IIIa inhibitors on platelet activation during renal artery intervention is unknown. Design, setting, participants, & measurements Plasma levels of sCD40L were measured in healthy controls, patients with atherosclerosis without renal stenosis, and patients with renal artery stenosis before, immediately after, and 24 hours after renal artery stenting. Results Soluble CD40L levels were higher in renal artery stenosis patients than normal controls (347.5 ± 27.0 versus 65.2 ± 1.4 pg/ml, P < 0.001), but were similar to patients with atherosclerosis without renal artery stenosis. Platelet-rich emboli were captured in 26% (9 of 35) of embolic protection device patients, and in these patients sCD40L was elevated before the procedure. Embolic protection device use was associated with a nonsignificant increase in sCD40L, whereas sCD40L declined with abciximab after the procedure (324.9 ± 42.5 versus 188.7 ± 31.0 pg/ml, P = 0.003) and at 24 hours. Conclusions Atherosclerotic renal artery stenosis is associated with platelet activation, but this appears to be related to atherosclerosis, not renal artery stenosis specifically. Embolization of platelet-rich thrombi is common in renal artery stenting and is inhibited with abciximab. PMID:21817131
Intervention Therapy for Portal Vein Stenosis/Occlusion After Pediatric Liver Transplantation.
Gao, Haijun; Wang, Hao; Chen, Guang; Yi, Zhengjia
2017-04-18
BACKGROUND The aim of this study was to investigate the outcomes and stent implantation timing of portal vein stenosis intervention after pediatric liver transplantation (pLT). MATERIAL AND METHODS The clinical data of 30 children with post-liver transplantation portal vein stenosis/occlusion (PVS/O) between Jan 2008 and Jun 2015 were retrospectively analyzed. The successfully re-opened cases used balloon angioplasty or stent implantation. SPSS13.0 software was used for statistical analysis and paired t test of the pressure gradient at both ends of the stenosis, diameter and flow rate within the stenosis, platelet count, and albumin in the PVS children before and after balloon angioplasty, with p<0.05 considered as statistically significant. Among the 30 patients, 6 received a stent implant in their first treatment, 22 received balloon angioplasty in their first treatment, and in 2 the re-opening could not be achieved. RESULTS The diameter of the stenotic segment, portal vein velocity, pressure gradient at both ends of the stenosis, and platelet count in these children with portal vein stenosis/occlusion (PVS/O) showed statistically significant differences when comparing values before and after intervention (p<0.05), but albumin showed no statistically significant difference (p>0.05). CONCLUSIONS Intervention therapy for portal vein stenosis after pediatric liver transplantation (pLT-PVS) is a safe and effective treatment, and patients with portal vein torsion, intimal tearing, or long portal vein segment occlusion should undergo stent implantation.
Mathematical model of carotid artery for stent placement
NASA Astrophysics Data System (ADS)
Rahman, Tengku Husna Tengku Abdul; Din, Ummul Khair Salma; Ahmad, Rokiah @ Rozita
2016-11-01
The carotid artery stenting is one of the methods used to reduce the effect of artherosclerosis which caused by the thickening of the artery wall. In most of the studies, the measure of wall elasticity, shear stress and the blood pressure through the blood flow were considered. The aim of this study is to determine the position to place the stent inside the carotid artery. A mathematical model is reconstructed to determine the suitable location of the stent in the carotid artery. Throughout the study, differences in fluid flow between a normal carotid artery wall and stenosed carotid artery wall are investigated. Since the existence of the stenosis provides a resistance in the flow, it is important to identify the right position to place the stent. The stent will be placed in the position where stenosis exists to ease the blood to flow normally. Later after the stent placement, the blood flow normally through the blood vessel.
Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery
NASA Astrophysics Data System (ADS)
Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris
2017-08-01
Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.
Brecker, Stephen; Mealing, Stuart; Padhiar, Amie; Eaton, James; Sculpher, Mark; Busca, Rachele; Bosmans, Johan; Gerckens, Ulrich J; Wenaweser, Peter; Tamburino, Corrado; Bleiziffer, Sabine; Piazza, Nicolo; Moat, Neil; Linke, Axel
2014-01-01
Objective To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK NHS. Methods A published decision-analytic model was adapted to include information on TAVI from the ADVANCE study. Patient-level data informed the choice as well as the form of mathematical functions that were used to model all-cause mortality, health-related quality of life and hospitalisations. TAVI-related resource use protocols were based on the ADVANCE study. MM was modelled on publicly available information from the PARTNER-B study. The outcome measures were incremental cost-effectiveness ratios (ICERs) estimated at a range of time horizons with benefits expressed as quality-adjusted life-years (QALY). Extensive sensitivity/subgroup analyses were undertaken to explore the impact of uncertainty in key clinical areas. Results Using a 5-year time horizon, the ICER for the comparison of all ADVANCE to all PARTNER-B patients was £13 943 per QALY gained. For the subset of ADVANCE patients classified as high risk (Logistic EuroSCORE >20%) the ICER was £17 718 per QALY gained). The ICER was below £30 000 per QALY gained in all sensitivity analyses relating to choice of MM data source and alternative modelling approaches for key parameters. When the time horizon was extended to 10 years, all ICERs generated in all analyses were below £20 000 per QALY gained. Conclusion TAVI is highly likely to be a cost-effective treatment for patients with severe aortic stenosis. PMID:25349700
Brecker, Stephen; Mealing, Stuart; Padhiar, Amie; Eaton, James; Sculpher, Mark; Busca, Rachele; Bosmans, Johan; Gerckens, Ulrich J; Wenaweser, Peter; Tamburino, Corrado; Bleiziffer, Sabine; Piazza, Nicolo; Moat, Neil; Linke, Axel
2014-01-01
To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK NHS. A published decision-analytic model was adapted to include information on TAVI from the ADVANCE study. Patient-level data informed the choice as well as the form of mathematical functions that were used to model all-cause mortality, health-related quality of life and hospitalisations. TAVI-related resource use protocols were based on the ADVANCE study. MM was modelled on publicly available information from the PARTNER-B study. The outcome measures were incremental cost-effectiveness ratios (ICERs) estimated at a range of time horizons with benefits expressed as quality-adjusted life-years (QALY). Extensive sensitivity/subgroup analyses were undertaken to explore the impact of uncertainty in key clinical areas. Using a 5-year time horizon, the ICER for the comparison of all ADVANCE to all PARTNER-B patients was £13 943 per QALY gained. For the subset of ADVANCE patients classified as high risk (Logistic EuroSCORE >20%) the ICER was £17 718 per QALY gained). The ICER was below £30 000 per QALY gained in all sensitivity analyses relating to choice of MM data source and alternative modelling approaches for key parameters. When the time horizon was extended to 10 years, all ICERs generated in all analyses were below £20 000 per QALY gained. TAVI is highly likely to be a cost-effective treatment for patients with severe aortic stenosis.
A Brief Review of Elasticity and Viscoelasticity
2010-05-27
through electromagnetic or acoustic means. Creating a model that accurately describes these Rayleigh waves is key to modeling and understanding the...technology to be feasible, a mathematical model that describes the propagation of the acoustic wave from the stenosis to the chest wall will be necessary...viscoelastic model is simpler to use than poroelastic models but yields similar results for a wide range of soils and dynamic 30 loadings. In addition
Bar-Meir, S; Geenen, J E; Hogan, W J; Dodds, W J; Stewart, E T; Arndorfer, R C
1979-03-01
Papillary stenosis is an imprecisely defined clinical syndrome which eludes definitive diagnosis. In this study we evaluated 26 patients with suspected papillary stenosis by manometric examination of the sphincter of Oddi done during ERCP examination. Basal pressure in the sphincter of Oddi was elevated in 14 of the patients. Of these 14 patients, 10 underwent sphincterotomy and all experienced improvement in clinical symptoms after their surgery. We suggest that ERCP manometry is a useful procedure for identifying patients with papillary stenosis who may benefit from sphincterotomy.
Zang, Chuanshan; Sun, Jian; Sun, Yan
2016-03-01
We report the treatment of one patient with pharynx anastomotic stenosis after cervical esophagealresection by stent implantation. The patient suffered from serious pharynx anastomotic stenosis after gastric-pha-ryngeal anastomosis. After balloon-dilatation,a domestic self-expanding Z-stents was implanted in the stricture ofthe esophagus under the X-rays. After stent implantation, the patient has been leading a normal life for threeyears. Balloon dilatation and stent implantation is an effective and safe method in the treatment of patients withpharynx anastomotic stenosis.
[Congenital esophageal stenosis: a case report].
Oquendo, Raquel; Resumil, Gisela; Villafañe, Vanesa; Flores, Mariana; Navacchia, Daniel; Quintana, Carlos
2014-03-01
Congenital esophageal stenosis, a rare disease of unknown cause which reports have increased in the last few years, requires a high index of suspicion for its diagnosis and treatment. It can be classified in three types based on the etiology of the stenosis: tracheobronchial rest, fibromuscular hypertrophy and membranous diaphragm. Symptoms may vary depending on location and severity of the stenosis. Treatment options are based on clinical suspicion of the histologic type and they can be balloon dilation or surgical resection of the stenotic segment. The definitive diagnosis is the histological study.
Diagnosis and management of carotid stenosis: a review.
Nussbaum, E S
2000-01-01
Since its introduction in the 1950s, carotid endarterectomy has become one of the most frequently performed operations in the United States. The tremendous appeal of a procedure that decreases the risk of stroke, coupled with the large number of individuals in the general population with carotid stenosis, has contributed to its popularity. To provide optimal patient care, the practicing physician must have a firm understanding of the proper evaluation and management of carotid stenosis. Nevertheless, because of the large number of clinical trials performed over the last decade addressing the treatment of stroke and carotid endarterectomy, the care of patients with carotid stenosis remains a frequently misunderstood topic. This review summarizes the current evaluation and treatment options for carotid stenosis and provides a rational management algorithm for this prevalent disease process.
Infundibulopelvic stenosis in children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucaya, J.; Enriquez, G.; Delgado, R.
1984-03-01
Of 11,500 children who underwent excretory urography during a 17-year period, three were found to have the rare renal malformation infundibulopelvic stenosis, characterized by caliceal dilatation, infundibular stenosis, and hypoplasia or stenosis of the renal pelvis. The contralateral kidney was absent in two cases and normal in the other. Voiding cystourethrograms were normal in all three. Renal sonography showed a variable degree of caliceal dilatation without associated pelvic dilatation. The diagnosis was confirmed by retrograde ureteropyelography in one case. Two patients were followed for 12 and 18 months, respectively; both remained asymptomatic with normal renal function, and sequential sonographic examinationsmore » of their kidneys have shown no significant changes. The third patient died of an unrelated condition. Infundibulopelvic stenosis has highly characteristic radiographic features, and prognosis is good for most affected patients.« less
Jang, E-Wook; Chung, Joonho; Seo, Kwon-Duk; Suh, Sang Hyun; Kim, Yong Bae; Lee, Kyung-Yul
2015-06-01
There are two established surgical treatment options for carotid artery stenosis. Carotid endarterectomy (CEA) has been accepted as a gold standard for surgical treatment while carotid artery stenting (CAS) has recently become an alternative option. Each treatment option has advantages and disadvantages for the treatment outcomes. We propose a protocol for selection of a proper surgical treatment option for carotid artery stenosis. A total of 192 published articles on management of carotid artery stenosis were reviewed. Preoperatively considerable factors which had been repeatedly noted in those articles for the risk/benefits of CEA or CAS were selected. According to those factors, a protocol with four categories was established. CEA or CAS is indicated when the patient has a symptomatic stenosis ≥ 50%, or when the patient has an asymptomatic stenosis ≥ 80%. Each treatment option has absolute indications and favorable indications. Each absolute indication is scored with three points, and each favorable indication, one point. Based on the highest scores, a proper treatment option (CEA or CAS) is selected. We have been treating patients according to this protocol and evaluating the outcomes of our protocol-based decision because this protocol might be helpful in assessment of risk/benefit for selection of a proper surgical treatment option in patients with carotid artery stenosis.
Hoffman, Matthew R; Mai, Johnny P; Dailey, Seth H
2017-10-30
The objective of this study was to describe a patient with idiopathic supraglottic stenosis who experienced persistent disease despite multiple office-based and operative interventions, whose disease is now better controlled with scheduled serial office-based steroid injections. This is a case report and literature review. A 42-year-old female was referred for worsening supraglottic stenosis despite systemic steroids. She underwent awake tracheotomy. A thorough historical, histologic, and laboratory workup did not reveal an etiology to her stenosis. She later underwent endoscopic partial laryngectomy and was able to be decannulated. She underwent a second endoscopic partial laryngectomy two years later for worsening disease and then was managed over the next seven years with intermittent systemic steroids. Over the last year, she has undergone eight office-based steroid injections with improvement in her degree of stenosis and symptom burden. There are only four prior reported cases of idiopathic supraglottic stenosis, none of which has been managed with serial office-based steroid injections. This case report adds to the small body of literature on the management of this rare disease and proposes a new office-based treatment pathway that may help induce regression of stenosis. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Anderson, W P; Johnston, C I; Korner, P I
1979-01-01
1. The acute renal haemodynamic and renin-angiotensin system responses to graded renal artery stenosis were studied in chronically instrumented, unanaesthetized dogs. 2. Stenosis was induced over 30 sec by inflation of a cuff around the renal artery to lower distal pressure to 60, 40 or 20 mmHg, with stenosis maintained for 1 hr. This resulted in an immediate fall in renal vascular resistance, but over the next 5--30 min both resistance and renal artery pressure were restored back towards prestenosis values. Only transient increases in systemic arterial blood pressure and plasma renin and angiotensin levels were seen with the two milder stenoses. Despite restoration of renal artery pressure, renal blood flow remained reduced at all grades of stenosis. 3. Pre-treatment with angiotensin I converting enzyme inhibitor or sarosine1, isoleucone8 angiotensin II greatly attenuated or abolished the restoration of renal artery pressure and renal vascular resistance after stenosis, and plasma renin and angiotensin II levels remained high. Renal dilatation was indefinitely maintained, but the normal restoration of resistance and pressure could be simulated by infusing angiotensin II into the renal artery. 4. The effective resistance to blood flow by the stenosis did not remain constant but varied with changes in the renal vascular resistance. PMID:219182
[Aqueductal stenosis in the neurofibromatosis type 1. Presentation of 19 infantile patients].
Pascual-Castroviejo, I; Pascual-Pascual, S I; Velázquez-Fragua, R; Viaño, J; Carceller-Benito, F
To present a series of infantile patients with aqueductal stenosis associated with neurofibromatosis type 1 (NF1). Nineteen patients with ages below 16 years, 11 girls and 8 boys, with NF1 presented hydrocephalus due to aqueductal stenosis. All patients, except one who died before the imaging study was performed and was diagnosed by autopsy, were studied by pneumoencephalography (since 1965 to 1974), computerized tomography (CT) (since 1975 to 1984), magnetic resonance (MR) or MR and CT (since 1985 to 2004) (two children had been studied by pneumoencephalography some years before) most times to discard optic pathway tumor and, in few patients, because of intracranial hypertension. All patients showed three ventricular hydrocephalus with aqueductal stenosis. Eleven patients showed optic pathway tumor. One patient had a benign aqueductal tumor that impaired the normal flow of cerebrospinal fluid. Neurological features of hydrocephalus occurred very rapidly in some patients and after several years of evolution in others. Two boys showed precocious puberty. All patients were treated with shunt. In our series, aqueductal stenosis occurred in about 5% of children with NF1. Aqueductal stenosis and hydrocephalus were identified at a short age because many patients were studied suspecting optic pathway tumor. Eleven patients (about 60%) associated optic pathway tumor and aqueductal stenosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ionita, C; Rudin, S; Bednarek, D
Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical propertiesmore » of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.« less
NASA Astrophysics Data System (ADS)
Peng, Zhiyou; Qin, Jinbao; Li, Bo; Ye, Kaichuang; Zhang, Yuxin; Yang, Xinrui; Yuan, Fukang; Huang, Lijia; Hu, Junqing; Lu, Xinwu
2015-04-01
Photothermal therapy (PTT), as a promising treatment for tumours, has rarely been reported for application in artery restenosis, which is a common complication of endovascular management due to enduring chronic inflammation and abnormal cell proliferation. In our study, biodegradable polypyrrole nanoparticles (PPy-NPs) were synthesized and characterized, including their size distribution, UV-vis-NIR absorbance, molar extinction coefficients, and photothermal properties. We then verified that PPy-NP incubation followed by 915 nm near-infrared (NIR) laser irradiation could effectively ablate inflammatory macrophages in vitro, leading to significant cell apoptosis and cell death. Further, it was found that a combination of local PPy-NP injection with 915 nm NIR laser irradiation could significantly alleviate arterial inflammation by eliminating infiltrating macrophages and further ameliorating artery stenosis in an ApoE-/- mouse model, without showing any obvious toxic side effects. Thus, we propose that PTT based on PPy-NPs as photothermal agents and a 915 nm NIR laser as a power source can serve as a new effective treatment for reducing inflammation and stenosis formation in inflamed arteries after endovascular management.Photothermal therapy (PTT), as a promising treatment for tumours, has rarely been reported for application in artery restenosis, which is a common complication of endovascular management due to enduring chronic inflammation and abnormal cell proliferation. In our study, biodegradable polypyrrole nanoparticles (PPy-NPs) were synthesized and characterized, including their size distribution, UV-vis-NIR absorbance, molar extinction coefficients, and photothermal properties. We then verified that PPy-NP incubation followed by 915 nm near-infrared (NIR) laser irradiation could effectively ablate inflammatory macrophages in vitro, leading to significant cell apoptosis and cell death. Further, it was found that a combination of local PPy-NP injection with 915 nm NIR laser irradiation could significantly alleviate arterial inflammation by eliminating infiltrating macrophages and further ameliorating artery stenosis in an ApoE-/- mouse model, without showing any obvious toxic side effects. Thus, we propose that PTT based on PPy-NPs as photothermal agents and a 915 nm NIR laser as a power source can serve as a new effective treatment for reducing inflammation and stenosis formation in inflamed arteries after endovascular management. Electronic supplementary information (ESI) available: Figures. See DOI: 10.1039/c5nr00542f
Wang, Hong-Yang; Liu, Long-Shan; Cao, Hai-Ming; Li, Jun; Deng, Rong-Hai; Fu, Qian; Zhang, Huan-Xi; Fei, Ji-Guang; Wang, Chang-Xi
Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann-Whitney U-test was used for analysis. Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P= 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P= 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P= 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P= 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions.
Wang, Hong-Yang; Liu, Long-Shan; Cao, Hai-Ming; Li, Jun; Deng, Rong-Hai; Fu, Qian; Zhang, Huan-Xi; Fei, Ji-Guang; Wang, Chang-Xi
2017-01-01
Background: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Methods: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–Whitney U-test was used for analysis. Results: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P = 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P = 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. Conclusions: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions. PMID:28051019
Tosteson, Anna N.A.; Lurie, Jon D.; Tosteson, Tor D.; Skinner, Jonathan S.; Herkowitz, Harry; Albert, Todd; Boden, Scott D.; Bridwell, Keith; Longley, Michael; Andersson, Gunnar B.; Blood, Emily A.; Grove, Margaret R.; Weinstein, James N.
2009-01-01
Background The SPORT (Spine Patient Outcomes Research Trial) reported favorable surgery outcomes over 2 years among patients with stenosis with and without degenerative spondylolisthesis, but the economic value of these surgeries is uncertain. Objective To assess the short-term cost-effectiveness of spine surgery relative to nonoperative care for stenosis alone and for stenosis with spondylolisthesis. Design Prospective cohort study. Data Sources Resource utilization, productivity, and EuroQol EQ-5D score measured at 6 weeks and at 3, 6, 12, and 24 months after treatment among SPORT participants. Target Population Patients with image-confirmed spinal stenosis, with and without degenerative spondylolisthesis. Time Horizon 2 years. Perspective Societal. Intervention Nonoperative care or surgery (primarily decompressive laminectomy for stenosis and decompressive laminectomy with fusion for stenosis associated with degenerative spondylolisthesis). Outcome Measures Cost per quality-adjusted life-year (QALY) gained. Results of Base-Case Analysis Among 634 patients with stenosis, 394 (62%) had surgery, most often decompressive laminectomy (320 of 394 [81%]). Stenosis surgeries improved health to a greater extent than nonoperative care (QALY gain, 0.17 [95% CI, 0.12 to 0.22]) at a cost of $77 600 (CI, $49 600 to $120 000) per QALY gained. Among 601 patients with degenerative spondylolisthesis, 368 (61%) had surgery, most including fusion (344 of 368 [93%]) and most with instrumentation (269 of 344 [78%]). Degenerative spondylolisthesis surgeries significantly improved health versus non-operative care (QALY gain, 0.23 [CI, 0.19 to 0.27]), at a cost of $115 600 (CI, $90 800 to $144 900) per QALY gained. Result of Sensitivity Analysis Surgery cost markedly affected the value of surgery. Limitation The study used self-reported utilization data, 2-year time horizon, and as-treated analysis to address treatment non-adherence among randomly assigned participants. Conclusion The economic value of spinal stenosis surgery at 2 years compares favorably with many health interventions. Degenerative spondylolisthesis surgery is not highly cost-effective over 2 years but could show value over a longer time horizon. PMID:19075203
Validation of a basic neurosonology laboratory for detecting cervical carotid artery stenosis.
de la Cruz Cosme, C; Dawid Milner, M S; Ojeda Burgos, G; Gallardo Tur, A; Márquez Martínez, M; Segura, T
2017-03-24
Most of the cases of ischaemic stroke in our setting are of atherothrombotic origin. Detecting intracranial and cervical carotid artery stenosis in patients with ischaemic stroke is therefore essential. Ultrasonography has become the tool of choice for diagnosing carotid artery stenosis because it is both readily accessibility and reliable. However, use of this technique must be validated in each laboratory. The purpose of this study is to validate Doppler ultrasound in our laboratory as a means of detecting severe carotid artery stenosis. We conducted an observational descriptive study to evaluate diagnostic tests. The results from transcranial and cervical carotid Doppler ultrasound scans conducted by neurologists were compared to those from carotid duplex scans performed by radiologists in patients diagnosed with stroke. Arteriography was considered the gold standard (MR angiography, CT angiography, or conventional arteriography). Our sample included 228 patients. Transcranial and cervical carotid Doppler ultrasound showed a sensitivity of 95% and specificity of 100% for detection of carotid artery stenosis > 70%, whereas carotid duplex displayed a sensitivity of 87% and a specificity of 94%. Transcranial carotid Doppler ultrasound achieved a sensitivity of 78% and a specificity of 98% for detection of intracranial stenosis. Doppler ultrasound in our neurosonology laboratory was found to be a useful diagnostic tool for detecting cervical carotid artery stenosis and demonstrated superiority to carotid duplex despite the lack of B-mode. Furthermore, this technique was found to be useful for detecting intracranial stenosis. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Ratchford, Elizabeth V.; Jin, Zhezhen; Di Tullio, Marco R.; Salameh, Maya J.; Homma, Shunichi; Gan, Robert; Boden-Albala, Bernadette; Sacco, Ralph L.; Rundek, Tatjana
2009-01-01
Objective The prevalence of carotid bruits and the utility of auscultation for predicting carotid stenosis are not well known. We aimed to establish the prevalence of carotid bruits and the diagnostic accuracy of auscultation for detection of hemodynamically significant carotid stenosis, using carotid duplex as the gold standard. Methods The Northern Manhattan Study (NOMAS) is a prospective multiethnic community-based cohort designed to examine the incidence of stroke and other vascular events and the association between various vascular risk factors and subclinical atherosclerosis. Of the stroke-free cohort (n=3298), 686 were examined for carotid bruits and underwent carotid duplex. Main outcome measures included prevalence of carotid bruits and sensitivity, specificity, positive predictive value, negative predictive value and accuracy of auscultation for prediction of ipsilateral carotid stenosis. Results Among 686 subjects with a mean age of 68.2 ± 9.4 years, the prevalence of ≥60% carotid stenosis as detected by ultrasound was 2.2% and the prevalence of carotid bruits was 4.1%. For detection of carotid stenosis, sensitivity of auscultation was 56%, specificity was 98%, positive predictive value was 25%, negative predictive value was 99% and overall accuracy was 97.5%. Discussion In this ethnically diverse cohort, the prevalence of carotid bruits and hemodynamically significant carotid stenosis was low. Sensitivity and positive predictive value were also low, and the 44% false-negative rate suggests that auscultation is not sufficient to exclude carotid stenosis. While the presence of a bruit may still warrant further evaluation with carotid duplex, ultrasonography may be considered in high-risk asymptomatic patients, irrespective of findings on auscultation. PMID:19133168
Igase, Keiji; Kumon, Yoshiaki; Matsubara, Ichiro; Arai, Masamori; Goishi, Junji; Watanabe, Hideaki; Ohnishi, Takanori; Sadamoto, Kazuhiko
2015-01-01
We evaluated the utility of 3-dimensional (3-D) ultrasound imaging for assessment of carotid artery stenosis, as compared with similar assessment via magnetic resonance angiography (MRA). Subjects comprised 58 patients with carotid stenosis who underwent both 3-D ultrasound imaging and MRA. We studied whether abnormal findings detected by ultrasound imaging could be diagnosed using MRA. Ultrasound images were generated using Voluson 730 Expert and Voluson E8. The degree of stenosis was mild in 17, moderate in 16, and severe in 25 patients, according to ultrasound imaging. Stenosis could not be recognized using MRA in 4 of 17 patients diagnosed with mild stenosis using ultrasound imaging. Ultrasound imaging showed ulceration in 13 patients and mobile plaque in 6 patients. When assessing these patients, MRA showed ulceration in only 2 of 13 patients and did not detect mobile plaque in any of these 6 patients. Static 3-D B mode images demonstrated distributions of plaque, ulceration, and mobile plaque, and static 3-D flow images showed flow configuration as a total structure. Real-time 3-D B mode images demonstrated plaque and vessel movement. Carotid artery stenting was not selected for patients diagnosed with ulceration or mobile plaque. Ultrasound imaging was necessary to detect mild stenosis, ulcerated plaque, or mobile plaque in comparison with MRA, and 3-D ultrasound imaging was useful to recognize carotid stenosis and flow pattern as a total structure by static and real-time 3-D demonstration. This information may contribute to surgical planning. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Yamada, Shigeki; Oshima, Marie; Watanabe, Yoshihiko; Ogata, Hideki; Hashimoto, Kenji; Miyake, Hidenori
2014-06-01
The purpose of this study was to investigate the association between internal carotid artery (ICA) stenosis and intramural location and size of calcification at the ICA origins and the origins of the cervical arteries proximal to the ICA. A total of 1139 ICAs were evaluated stenosis and calcification on the multi-detector row CT angiography. The intramural location was categorized into none, outside and inside location. The calcification size was evaluated on the 4-point grading scale. The multivariate analyses were adjusted for age, serum creatinine level, hypertension, hyperlipidemia, diabetes mellitus, smoking and alcohol habits. Outside calcification at the ICA origins showed the highest multivariate odds ratio (OR) for the presence of ICA stenosis (30.0) and severe calcification (a semicircle or more of calcification at the arterial cross-sectional surfaces) did the second (14.3). In the subgroups of >70% ICA stenosis, the multivariate OR of outside location increased to 44.8 and that of severe calcification also increased to 32.7. Four of 5 calcified carotid plaque specimens extracted by carotid endarterectomy were histologically confirmed to be calcified burdens located outside the internal elastic lamia which were defined as arterial medial calcification. ICA stenosis was strongly associated with severe calcification located mainly outside the carotid plaque. Outside calcification at the ICA origins should be evaluated separately from inside calcification, as a marker for the ICA stenosis. Additionally, we found that calcification at the origins of the cervical arteries proximal to the ICA was significantly associated with the ICA stenosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
The role of mitomycin C in preventing synechia and stenosis after endoscopic sinus surgery.
Anand, Vijay K; Tabaee, Abtin; Kacker, Ashutosh; Newman, Jason G; Huang, Clark
2004-01-01
Synechia and stenosis formation after endoscopic sinus surgery (ESS) represents a potential source of surgical failure. Mitomycin C (MMC) has been used successfully in other fields to decrease postoperative scar formation. We hypothesize that the topical application of MMC reduces the incidence of stenosis and synechia formation after ESS. This study is a randomized, controlled, single-blinded study based in a tertiary care teaching hospital. After routine ESS, a pledget soaked in MMC (0.5%) was randomly placed into the middle meatus of one nasal cavity for 5 minutes and a pledget soaked in saline was placed in the contralateral side in each patient. A blinded observer followed the patients for any evidence of stenosis or synechia formation. The medical records of enrolled patients were reviewed for demographics, diagnosis, prior surgery, type of sinus surgery, complications, incidence of stenosis/synechia, and need for further procedures. Twenty-nine patients were included in the final analysis. The mean follow-up period was 15 months (range, 3-32 months). There were no complications in this series. Eight patients experienced 10 episodes of synechia formation and one patient experienced 1 episode of synechia formation and 1 episode of stenosis of the maxillary sinus ostium. Seven of the 12 episodes of synechia/stenosis occurred on the side of the MMC application and the remaining 5 episodes occurred on the side opposite to the MMC application. This difference was not statistically significant. The topical application of MMC did not decrease the incidence of stenosis and synechia formation after ESS.
Comparative Review of the Treatment Methodologies of Carotid Stenosis
Bae, Coney; Szuchmacher, Mauricio; Chang, John B.
2015-01-01
The treatment of carotid stenosis entails three methodologies, namely, medical management, carotid angioplasty and stenting (CAS), as well as carotid endarterectomy (CEA). The North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trial (ECST) have shown that symptomatic carotid stenosis greater than 70% is best treated with CEA. In asymptomatic patients with carotid stenosis greater than 60%, CEA was more beneficial than treatment with aspirin alone according to the Asymptomatic Carotid Atherosclerosis (ACAS) and Asymptomatic Carotid Stenosis Trial (ACST) trials. When CAS is compared with CEA, the CREST resulted in similar rates of ipsilateral stroke and death rates regardless of symptoms. However, CAS not only increased adverse effects in women, it also amplified stroke rates and death in elderly patients compared with CEA. CAS can maximize its utility in treating focal restenosis after CEA and patients with overwhelming cardiac risk or prior neck irradiation. When performing CEA, using a patch was equated to a more durable result than primary closure, whereas eversion technique is a new methodology deserving a spotlight. Comparing the three major treatment strategies of carotid stenosis has intrinsic drawbacks, as most trials are outdated and they vary in their premises, definitions, and study designs. With the newly codified best medical management including antiplatelet therapies with aspirin and clopidogrel, statin, antihypertensive agents, strict diabetes control, smoking cessation, and life style change, the current trials may demonstrate that asymptomatic carotid stenosis is best treated with best medical therapy. The ongoing trials will illuminate and reshape the treatment paradigm for symptomatic and asymptomatic carotid stenosis. PMID:26417191
Quantification of uncertainties for application in detonation simulation
NASA Astrophysics Data System (ADS)
Zheng, Miao; Ma, Zhibo
2016-06-01
Numerical simulation has become an important means in designing detonation systems, and the quantification of its uncertainty is also necessary to reliability certification. As to quantifying the uncertainty, it is the most important to analyze how the uncertainties occur and develop, and how the simulations develop from benchmark models to new models. Based on the practical needs of engineering and the technology of verification & validation, a framework of QU(quantification of uncertainty) is brought forward in the case that simulation is used on detonation system for scientific prediction. An example is offered to describe the general idea of quantification of simulation uncertainties.
Faisal, Mohamed; Harun, Hafaruzi; Hassan, Tidi M; Ban, Andrea Y L; Chotirmall, Sanjay H; Abdul Rahaman, Jamalul Azizi
2016-04-14
Tracheobronchial stenosis is a known complication of endobronchial tuberculosis. Despite antituberculous and steroid therapy, the development of bronchial stenosis is usually irreversible and requires airway patency to be restored by either bronchoscopic or surgical interventions. We report the use of balloon dilatation and topical mitomycin-C to successful restore airway patency. We present a 24-year old lady with previous pulmonary tuberculosis and laryngeal tuberculosis in 2007 and 2013 respectively who presented with worsening dyspnoea and stridor. She had total left lung collapse with stenosis of both the upper trachea and left main bronchus. She underwent successful bronchoscopic balloon and manual rigid tube dilatation with topical mitomycin-C application over the stenotic tracheal segment. A second bronchoscopic intervention was performed after 20 weeks for the left main bronchus stenosis with serial balloon dilatation and topical mitomycin-C application. These interventions led to significant clinical and radiographic improvements. This case highlights that balloon dilatation and topical mitomycin-C application should be considered in selected patients with tracheobronchial stenosis following endobronchial tuberculosis, avoiding airway stenting and invasive surgical intervention.
Elemental Study on Auscultaiting Diagnosis Support System of Hemodialysis Shunt Stenosis by ANN
NASA Astrophysics Data System (ADS)
Suzuki, Yutaka; Fukasawa, Mizuya; Mori, Takahiro; Sakata, Osamu; Hattori, Asobu; Kato, Takaya
It is desired to detect stenosis at an early stage to use hemodailysis shunt for longer time. Stethoscope auscultation of vascular murmurs is useful noninvasive diagnostic approach, but an experienced expert operator is necessary. Some experts often say that the high-pitch murmurs exist if the shunt becomes stenosed, and some studies report that there are some features detected at high frequency by time-frequency analysis. However, some of the murmurs are difficult to detect, and the final judgment is difficult. This study proposes a new diagnosis support system to screen stenosis by using vascular murmurs. The system is performed using artificial neural networks (ANN) with the analyzed frequency data by maximum entropy method (MEM). The author recorded vascular murmurs both before percutaneous transluminal angioplasty (PTA) and after. Examining the MEM spectral characteristics of the high-pitch stenosis murmurs, three features could be classified, which covered 85 percent of stenosis vascular murmurs. The features were learnt by the ANN, and judged. As a result, a percentage of judging the classified stenosis murmurs was 100%, and that of normal was 86%.
Left main coronary artery stenosis: severity evaluation and implications for management.
Habibi, Susan E; Shah, Rahman; Berzingi, Chalak O; Melchior, Ryan; Sumption, Kevin F; Jovin, Ion S
2017-03-01
The significant stenosis of the left main coronary artery is associated with poor outcomes and is considered a strong indication for revascularization. However, deciding whether the stenosis is significant can sometimes be challenging, especially when the degree of stenosis is intermediate, and can necessitate additional tests and imaging modalities. Areas covered: We did a literature search using keywords like 'left main', 'imaging', 'intravascular ultrasound', 'fractional flow reserve', 'computed tomographic angiography' and 'magnetic resonance imaging'. The most commonly used methods for better characterizing intermediate left main coronary stenoses are intravascular ultrasound and fractional flow reserve, while optical coherence tomography is the newer technique that provides better images, but for which not as much data is available. The noninvasive techniques are coronary computed tomographic angiography and, to a lesser degree, coronary magnetic resonance imaging. Expert commentary: Accurately determining the severity of left main coronary stenosis can mean the difference between a major intervention and conservative therapy. The reviewed newer imaging modalities give us greater confidence that patients with left main stenosis are assigned to the right treatment modality.
2014-01-01
Aim For patients with superficial esophageal carcinoma, ESD was one of treatment modalities to remove the lesion safely and effectively. We perform this meta-analysis to determine the efficacy and incidence of complication of ESD for patients with superficial esophageal carcinoma. Method Articles were searched in MEDLINE (PubMed and Ovid), Cochrane Database of Systemic Reviews, Google scholar, and Web of Science. Two reviewers independently searched and extracted data. Meta-analysis of the efficacy of ESD was analyzed by calculating pooled en bloc and R0 resection rate. Incidence of complications such as perforation, stenosis and mediastinal emphysema was also calculated. Pooling was conducted using either fixed-effects model or random-effects model depending on the heterogeneity across studies. Results 21 studies (1152 patients and 1240 lesions) were included in this analysis. The pooled en bloc resection rate was 99% (95% CI 99%-100%). Stratified by tumor size, en bloc resection rates did not show any significant difference. The pooled R0 resection rate was 90% (95% CI 87%-93%). The pooled R0 resection rate was 85% (95% CI, 80%-90%) for large tumor and 92% (95% CI, 87%-93%) for small tumor (p < 0.001). Stenosis served as the most common reported complication with pooled incidence of 5% (95% CI 3-8%), followed by perforation (1%, 95% CI 0-1%) and mediastinal emphysema (0% CI 0-1%). The incidence of postoperative stenosis decreased significantly after 2011 (2%, 95% CI 0-3%) compared with that before 2011 (9%, 95% CI 3-8%) (p < 0.001). Conclusion ESD was an efficient modality for treating superficial esophageal carcinoma, with perfect en bloc and R0 resection rate and low complication rate. The most common complication of ESD was stenosis. Although recurrence rate was low, patients should be maintained in a scheduled surveillance program. PMID:24885614
Almalki, Manal; Gray, Kathleen; Sanchez, Fernando Martin
2015-01-01
Self-quantification is seen as an emerging paradigm for health care self-management. Self-quantification systems (SQS) can be used for tracking, monitoring, and quantifying health aspects including mental, emotional, physical, and social aspects in order to gain self-knowledge. However, there has been a lack of a systematic approach for conceptualising and mapping the essential activities that are undertaken by individuals who are using SQS in order to improve health outcomes. In this paper, we propose a new model of personal health information self-quantification systems (PHI-SQS). PHI-SQS model describes two types of activities that individuals go through during their journey of health self-managed practice, which are 'self-quantification' and 'self-activation'. In this paper, we aimed to examine thoroughly the first type of activity in PHI-SQS which is 'self-quantification'. Our objectives were to review the data management processes currently supported in a representative set of self-quantification tools and ancillary applications, and provide a systematic approach for conceptualising and mapping these processes with the individuals' activities. We reviewed and compared eleven self-quantification tools and applications (Zeo Sleep Manager, Fitbit, Actipressure, MoodPanda, iBGStar, Sensaris Senspod, 23andMe, uBiome, Digifit, BodyTrack, and Wikilife), that collect three key health data types (Environmental exposure, Physiological patterns, Genetic traits). We investigated the interaction taking place at different data flow stages between the individual user and the self-quantification technology used. We found that these eleven self-quantification tools and applications represent two major tool types (primary and secondary self-quantification systems). In each type, the individuals experience different processes and activities which are substantially influenced by the technologies' data management capabilities. Self-quantification in personal health maintenance appears promising and exciting. However, more studies are needed to support its use in this field. The proposed model will in the future lead to developing a measure for assessing the effectiveness of interventions to support using SQS for health self-management (e.g., assessing the complexity of self-quantification activities, and activation of the individuals).
2015-01-01
Background Self-quantification is seen as an emerging paradigm for health care self-management. Self-quantification systems (SQS) can be used for tracking, monitoring, and quantifying health aspects including mental, emotional, physical, and social aspects in order to gain self-knowledge. However, there has been a lack of a systematic approach for conceptualising and mapping the essential activities that are undertaken by individuals who are using SQS in order to improve health outcomes. In this paper, we propose a new model of personal health information self-quantification systems (PHI-SQS). PHI-SQS model describes two types of activities that individuals go through during their journey of health self-managed practice, which are 'self-quantification' and 'self-activation'. Objectives In this paper, we aimed to examine thoroughly the first type of activity in PHI-SQS which is 'self-quantification'. Our objectives were to review the data management processes currently supported in a representative set of self-quantification tools and ancillary applications, and provide a systematic approach for conceptualising and mapping these processes with the individuals' activities. Method We reviewed and compared eleven self-quantification tools and applications (Zeo Sleep Manager, Fitbit, Actipressure, MoodPanda, iBGStar, Sensaris Senspod, 23andMe, uBiome, Digifit, BodyTrack, and Wikilife), that collect three key health data types (Environmental exposure, Physiological patterns, Genetic traits). We investigated the interaction taking place at different data flow stages between the individual user and the self-quantification technology used. Findings We found that these eleven self-quantification tools and applications represent two major tool types (primary and secondary self-quantification systems). In each type, the individuals experience different processes and activities which are substantially influenced by the technologies' data management capabilities. Conclusions Self-quantification in personal health maintenance appears promising and exciting. However, more studies are needed to support its use in this field. The proposed model will in the future lead to developing a measure for assessing the effectiveness of interventions to support using SQS for health self-management (e.g., assessing the complexity of self-quantification activities, and activation of the individuals). PMID:26019809
Chugh, Arunit J S; Weinberg, Douglas S; Alonso, Fernando; Eubanks, Jason D
2017-11-01
Retrospective cohort review. To determine whether preoperative cord rotation is independently correlated with C5 palsy when analyzed alongside measures of sagittal balance and foraminal stenosis. Postoperative C5 palsy is a well-documented complication of cervical procedures with a prevalence of 4%-8%. Recent studies have shown a correlation with preoperative spinal cord rotation. There have been few studies, however, that have examined the role of sagittal balance and foraminal stenosis in the development of C5 palsy. A total of 77 patients who underwent cervical decompression-10 of whom developed C5 palsy-were reviewed. Sagittal balance was assessed using curvature angle and curvature index on radiographs and magnetic resonance image (MRI). Cord rotation was assessed on axial MRI. C4-C5 foraminal stenosis was assessed on sagittal MRI using area measurements and a grading scale. Demographics and information on surgical approach were gathered from chart review. Correlation with C5 palsy was performed by point-biserial, χ, and regression analyses. Point-biserial analysis indicated that only cord rotation showed significance (P<0.01). There was no statistical significance shown with surgical approach, sex, or age. In addition, changes in sagittal balance did not correlate with presence of C5 palsy. Logistic regression model yielded cord rotation as the only significant independent predictor of C5 palsy. For every degree of axial cord rotation, the likelihood ratio for suffering a C5 palsy was 3.93 (95% confidence interval, 2.01-8.66; P<0.05). This supports the independent capability of preoperative cord rotation to predict postoperative C5 palsy. Lack of correlation with measures of neuroforaminal stenosis potentially points to mechanisms other than direct compression as the etiology. In addition, the lack of correlation with postoperative changes in sagittal balance hints that measures of curvature angle and curvature index may not be appropriate to accurately predict this complication. Level 3.
Schölvinck, D W; Alvarez Herrero, L; Visser, M; Bergman, J J G H M; Weusten, B L A M
2015-10-01
Preliminary data show higher stricture rates after radiofrequency ablation (RFA) for early esophageal squamous neoplasia compared with Barrett's esophagus. We studied the effects of Lugol stain (LS) directly prior to RFA on stricture formation in squamous epithelium. Of 16 pigs, the distal half of the esophagus was LS, followed by circumferential RFA (single application 12 J/cm(2) ) in the unstained and stained esophagus. Pigs were euthanized at day 0 (n = 4), 3 (n = 4), or 28 (n = 8). Histology was evaluated in four areas: blank-control (no RFA, no LS), blank-RFA (no LS), LS+RFA, and LS-control (no RFA). Stenosis severity in LS+RFA and blank-RFA at 28 days was assessed by the ratio of the mucosal diameter at the RFA area to the diameter 2 cm proximal of this zone. Histology showed submucosal edema in 50% of LS+RFA versus 0% in blank-RFA. Severity and depth of inflammation (day 3) was equal in LS+RFA and blank-RFA. Severity and depth of fibrosis (day 28) appeared more severe in LS+RFA. Consequently, stenosis was present in 100% (LS+RFA) versus 12.5% (blank-RFA). The stenosis-severity ratio was 0.40 (interquartile range 0.29-0.45) in LS+RFA versus 0.73 (interquartile range 0.64-0.78) in blank-RFA (P = 0.012). Limitations of this study were the difference in uptake of LS between pigs and humans, the difference in esophageal anatomy between pigs and humans, and between the proximal and distal esophagus within pigs. In conclusion, in the porcine squamous esophagus, stenosis rate and severity after RFA increased when preceded by LS. LS may be contributing in the altered response of squamous epithelium to RFA as compared with Barrett's esophagus. © 2014 International Society for Diseases of the Esophagus.
Nasopharyngeal stenosis with concurrent hiatal hernia and megaesophagus in an 8-year-old cat.
DeSandre-Robinson, Dana M; Madden, Stacey N; Walker, Jackson T
2011-06-01
A case of nasopharyngeal stenosis with secondary hiatal hernia is described. An 8-year-old castrated male domestic shorthair cat was referred for a chronic upper respiratory problem and presumptive vomiting. Despite conservative management by the primary care veterinarian, the cat's condition progressed. The cat was presented to an emergency facility prior to referral to a specialty hospital. On presentation, inspiratory stridor was evident. Thoracic radiography revealed a hiatal hernia. Computed tomography indicated pharyngeal edema and probable nasopharyngeal stenosis. Endoscopy confirmed the presence of nasopharyngeal stenosis consistent with either stricture or choanal atresia. Balloon dilation of the choana was performed. The hiatal hernia regressed spontaneously post-resolution of the nasopharyngeal stenosis. The cat remained asymptomatic at recheck 3 months later. Copyright © 2011 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Congenital esophageal stenosis owing to tracheobronchial remnants.
Rebelo, Priscila Guyt; Ormonde, João Victor C; Ormonde Filho, João Baptista C
2013-09-01
OBJECTIVE To emphasize the need of an accurate diagnosis of congenital esophageal stenosis due to tracheobronchial remnants, since its treatment differs from other types of congenital narrowing. CASE DESCRIPTION Four cases of lower congenital esophageal stenosis due to tracheobronchial remnants, whose definitive diagnosis was made by histopathology. Except for the last case, in which a concomitant anti-reflux surgery was not performed, all had a favorable outcome after resection and anastomosis of the esophagus. COMMENTS The congenital esophageal stenosis is an intrinsic narrowing of the organ's wall associated with its structural malformation. The condition can be caused by tracheobronchial remnants, fibromuscular stenosis or membranous diaphragm and the first symptom is dysphagia after the introduction of solid food in the diet. The first-choice treatment to tracheobronchial remnants cases is the surgical resection and end-to-end anastomosis of the esophagus.
Merwick, Áine; Albers, Gregory W; Arsava, Ethem M; Ay, Hakan; Calvet, David; Coutts, Shelagh B; Cucchiara, Brett L; Demchuk, Andrew M; Giles, Matthew F; Mas, Jean-Louis; Olivot, Jean Marc; Purroy, Francisco; Rothwell, Peter M; Saver, Jeffrey L; Sharma, Vijay K; Tsivgoulis, Georgios; Kelly, Peter J
2013-01-01
Background and Purpose Statins reduce stroke risk when initiated months after TIA/stroke and reduce early vascular events in acute coronary syndromes, possibly via pleiotropic plaque-stabilisation. Few data exist regarding acute statin use in TIA. We aimed to determine if statin pre-treatment at TIA onset modified early stroke risk in carotid stenosis. Methods We analyzed data from 2770 TIA patients from 11 centres, 387 with ipsilateral carotid stenosis. ABCD2 score, abnormal DWI, medication pre-treatment, and early stroke were recorded. Results In patients with carotid stenosis, 7-day stroke risk was 8.3% (95% confidence interval [CI] 5.7–11.1) compared with 2.7% [CI 2.0–3.4%] without stenosis (p<0.0001) (90-day risks 17.8% and 5.7% [p<0.0001]). Among carotid stenosis patients, non-procedural 7-day stroke risk was 3.8% [CI 1.2–9.7%] with statin treatment at TIA onset, compared to 13.2% [CI 8.5–19.8%] in those not statin pre-treated (p=0.01) (90-day risks 8.9% versus 20.8% [p=0.01]). Statin pre-treatment was associated with reduced stroke risk in carotid stenosis patients (OR for 90-day stroke 0.37, CI 0.17–0.82), but not non-stenosis patients (OR 1.3, CI 0.8–2.24) (p for interaction 0.008). On multivariable logistic regression, the association remained after adjustment for ABCD2 score, smoking, antiplatelet treatment, recent TIA, and DWI hyperintensity (adjusted p for interaction 0.054). Conclusion In acute symptomatic carotid stenosis, statin pre-treatment was associated with reduced stroke risk, consistent with findings from randomized trials in acute coronary syndromes. These data support the hypothesis that statins started acutely after TIA symptom onset may also be beneficial to prevent early stroke. Randomized trials addressing this question are required. PMID:23908061
Acquired external punctal stenosis: surgical management and long-term follow-up.
Kashkouli, Mohsen Bahmani; Beigi, Bijan; Astbury, Nick
2005-06-01
To introduce and assess the results of a long-term follow-up of a one-snip punctoplasty with monocanalicular stent (Mini Monoka) for acquired external punctal stenosis (AEPS) with and without associated internal punctal and canalicular stenosis. Prospective non-comparative interventional case series. Thirty-five eligible patients (53 eyes) with AEPS underwent a horizontal one-snip punctoplasty and Mini Monoka tube insertion by or under supervision of a consultant Oculoplastic surgeon from June 1999 to May 2002. Diagnostic probing and irrigation were performed before operation and after operation at the last follow-up. Patients with canalicular obstruction, nasolacrimal duct stenosis and obstruction, and those with less than 6 months' follow-up were excluded. The Chi-square (X(2)), Fisher's exact, Pearson correlation, and multiple logistic regression analysis tests, with 95% confidence interval when appropriate, were used for statistical analysis. The age range was 39 to 90 years (mean: 67.2, SD: 11.8, SE: 2). Twenty-seven patients (77.1%) were female. There was a normal canalicular system in 21 (39.6%), lower canalicular stenosis in 10 (18.8%), and internal punctal stenosis in 22 (41.5%) eyes. Postoperative follow-up was from 6 to 41 months (mean: 18.5, SD: 9.2, SE: 1.2). There was a 77.4% complete functional success, 7.5% partial functional success, and 96.2% anatomical success at the last follow-up. The success rate was not significantly different between the eyes with and without preoperative internal punctal and canalicular stenosis (p = 0.4). The lower success rate was significantly correlated with a final abnormal probing and irrigation (p < 0.01). The use of a monocanalicular Mini Monoka stent together with a one-snip punctoplasty is helpful to prevent the recurrence of punctal stenosis in the healing phase and addresses the associated internal punctal and canalicular stenosis.
Wijntjens, Gilbert W M; van de Hoef, Tim P; Kraak, Robin P; Beijk, Marcel A; Sjauw, Krischan D; Vis, M Marije; Madera Cambero, Maribel I; Brinckman, Stijn L; Plomp, Jacobus; Baan, Jan; Koch, Karel T; Wykrzykowska, Joanna J; Henriques, José P; de Winter, Robbert J; Piek, Jan J
2016-12-01
The Navvus pressure sensor-equipped microcatheter allows to measure functional stenosis severity over a work-horse guidewire and is used as a more feasible alternative to regular sensor-equipped wires. However, Navvus is larger in diameter than contemporary sensor-equipped guidewires and may, thereby, influence functional measurements. The present study evaluates the hemodynamic influence of the Navvus microcatheter. In patients with intermediate coronary stenosis, coronary pressure and flow velocity were measured using a dual sensor-equipped guidewire before and after introduction of Navvus. Patients were randomized to microcatheter-first or guidewire-first measurement. The primary end point was the difference in hyperemic stenosis resistance index between measurements before and after introduction of Navvus. Measurements were completed in 28 patients (28 stenoses). Mean hyperemic stenosis resistance was 0.37±0.19 Hg/cm/s for wire-only assessment and 0.48±0.26 Hg/cm/s after Navvus introduction (P<0.001). Bland-Altman analysis documented a mean bias of +0.11 Hg/cm/s (limits of agreement: -0.13 to 0.36), proportional to mean hyperemic stenosis resistance (Spearman ρ =0.61; P=0.001). Passing-Bablok analysis revealed absence of a constant difference but significant proportional difference between the methods. Mean fractional flow reserve was 0.86±0.06 for wire-only assessment and 0.82±0.07 after Navvus introduction (P<0.001). Bland-Altman analysis documented a mean bias of -0.033 (limits of agreement: -0.09 to 0.03), proportional to mean fractional flow reserve (Spearman ρ =0.40; P=0.036). Passing-Bablok analysis revealed significant constant and proportional differences between methods. Similar results were documented for resting indices of stenosis severity. Introduction of the Navvus microcatheter leads to clinically relevant stenosis severity overestimation in intermediate stenosis. © 2016 American Heart Association, Inc.
Lin, Ting-Chao; Huang, Chun-Yang; Chen, Po-Lin; Lee, Chiu-Yang; Shih, Chun-Che; Chen, I-Ming
2018-06-01
To report a retrospective analysis of risk factors for edge restenosis after Viabahn stent-graft treatment of superficial femoral artery (SFA) occlusive disease and determine any protective effect of drug-coated balloons (DCBs) used at the time of stent-graft implantation. Between October 2011 and July 2016, 110 patients (mean age 73.3±7.6 years; 78 men) were treated with the Viabahn stent-graft for long SFA occlusions. Thirty-eight (34.5%) patients had DCB reinforcement at the distal edge of the stent-graft. For analysis, the population was divided into groups of no edge stenosis patients (n=88; mean lesion length 22.4±4.2 cm) and edge stenosis patients (n=22; mean lesion length 23.5±5.7 cm). The clinical outcomes, ankle-brachial indices, computed tomography angiography findings, and patency were compared at a minimum of 12 months. Logistic regression analysis was employed to determine risk factors for edge stenosis; the results are presented as the odds ratio (OR) and 95% confidence interval. No differences in clinical or procedural characteristics were identified except the higher incidence of diabetes (p=0.008) and greater need for retrograde access (p=0.033) in the edge stenosis group. DCB reinforcement reduced the incidence of edge stenosis (p=0.021) and target lesion revascularization (TLR; p=0.010) and resulted in a significantly higher 1-year primary patency rate (92.1% vs 76.4%, p=0.042). However, multivariate analysis revealed only poor distal runoff (OR 0.31, 95% CI 0.11 to 0.83, p=0.020) as a predictor of edge stenosis. The risk of edge stenosis after Viabahn implantation was higher in patients with poor distal runoff. DCB reinforcement over the distal edge reduced edge stenosis, decreased 1-year TLR, and improved 1-year primary patency.
Esophagram findings in cervical esophageal stenosis: A case-controlled quantitative analysis.
West, Jacob; Kim, Cherine H; Reichert, Zachary; Krishna, Priya; Crawley, Brianna K; Inman, Jared C
2018-01-04
Cervical esophageal stenosis is often diagnosed with a qualitative evaluation of a barium esophagram. Although the esophagram is frequently the initial screening exam for dysphagia, a clear objective standard for stenosis has not been defined. In this study, we measured esophagram diameters in order to establish a quantitative standard for defining cervical esophageal stenosis that requires surgical intervention. Single institution case-control study. Patients with clinically significant cervical esophageal stenosis defined by moderate symptoms of dysphagia (Functional Outcome Swallowing Scale > 2 and Functional Oral Intake Scale < 6) persisting for 6 months and responding to dilation treatment were matched with age, sex, and height controls. Both qualitative and quantitative barium esophagram measurements for the upper, mid-, and lower vertebral bodies of C5 through T1 were analyzed in lateral, oblique, and anterior-posterior views. Stenotic patients versus nonstenotic controls showed no significant differences in age, sex, height, body mass index, or ethnicity. Stenosis was most commonly at the sixth cervical vertebra (C 6) lower border and C7 upper border. The mean intraesophageal minimum/maximum ratios of controls and stenotic groups in the lateral view were 0.63 ± 0.08 and 0.36 ± 0.12, respectively (P < 0.0001). Receiver operating characteristic analysis of the minimum/maximum ratios, with a <0.50 ratio delineating stenosis, demonstrated that lateral view measurements had the best diagnostic ability. The sensitivity of the radiologists' qualitative interpretation was 56%. With application of lateral intraesophageal minimum/maximum ratios, we observed improved sensitivity to 94% of the esophagram, detecting clinically significant stenosis. Applying quantitative determinants in esophagram analysis may improve the sensitivity of detecting cervical esophageal stenosis in dysphagic patients who may benefit from surgical therapy. IIIb. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.
Rubeosis iridis as a sign of underlying carotid stenosis.
Oller, Mar; Esteban, Carlos; Pérez, Paulina; Parera, M Àngels; Lerma, Rosa; Llagostera, Secundino
2012-12-01
Severe carotid stenosis may be associated with uncommon clinical symptoms. We report a case of ocular ischemic syndrome and subsequent rubeosis iridis due to a high-grade carotid stenosis. The patient recovered visual acuity and his normal iris coloring after carotid endarterectomy. Rubeosis iridis may be the only clinical sign associated with severe carotid stenosis, making it mandatory to rule out the presence of carotid narrowing when it is detected. Establishing an early diagnosis is essential to improve quality of life, prognosis, and patients' outcome. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Intracranial stenosis in cognitive impairment and dementia.
Hilal, Saima; Xu, Xin; Ikram, M Kamran; Vrooman, Henri; Venketasubramanian, Narayanaswamy; Chen, Christopher
2017-06-01
Intracranial stenosis is a common vascular lesion observed in Asian and other non-Caucasian stroke populations. However, its role in cognitive impairment and dementia has been under-studied. We, therefore, examined the association of intracranial stenosis with cognitive impairment, dementia and their subtypes in a memory clinic case-control study, where all subjects underwent detailed neuropsychological assessment and 3 T neuroimaging including three-dimensional time-of-flight magnetic resonance angiography. Intracranial stenosis was defined as ≥50% narrowing in any of the intracranial arteries. A total of 424 subjects were recruited of whom 97 were classified as no cognitive impairment, 107 as cognitive impairment no dementia, 70 vascular cognitive impairment no dementia, 121 Alzheimer's Disease, and 30 vascular dementia. Intracranial stenosis was associated with dementia (age/gender/education - adjusted odds ratios (OR): 4.73, 95% confidence interval (CI): 1.93-11.60) and vascular cognitive impairment no dementia (OR: 3.98, 95% CI: 1.59-9.93). These associations were independent of cardiovascular risk factors and MRI markers. However, the association with Alzheimer's Disease and vascular dementia became attenuated in the presence of white matter hyperintensities. Intracranial stenosis is associated with vascular cognitive impairment no dementia independent of MRI markers. In Alzheimer's Disease and vascular dementia, this association is mediated by cerebrovascular disease. Future studies focusing on perfusion and functional markers are needed to determine the pathophysiological mechanism(s) linking intracranial stenosis and cognition so as to identify treatment strategies.
In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV
NASA Astrophysics Data System (ADS)
Park, Hanwook; Park, Jun Hong; Lee, Sang Joon
2016-11-01
Measurements of the hemodynamic information of blood flows, especially wall shear stress (WSS), in animal models with circulatory vascular diseases (CVDs) are important to understand the pathological mechanism of CVDs. In this study, X-ray particle image velocimetry (PIV) with high spatial resolution was applied to obtain velocity field information in stenosed blood vessels with high WSS. 3D clips fabricated with a 3D printer were applied to the abdominal aorta of a rat cadaver to induce artificial stenosis in the real blood vessel of an animal model. The velocity and WSS information of blood flows in the stenosed vessel were obtained and compared at various stenosis severities. In vivo measurement was also conducted by fastening a stenotic clip on a live rat model through surgical intervention to reduce the flow rate to match the limited temporal resolution of the present X-ray PIV system. Further improvement of the temporal resolution of the system might be able to provide in vivo measurements of hemodynamic information from animal disease models under physiological conditions. The present results would be helpful for understanding the relation between hemodynamic characteristics and the pathological mechanism in animal CVD models.
Lin, Dexin; Wu, Xianbin; Ji, Xiaoke; Zhang, Qiyu; Lin, YuanWei; Chen, WeiJian; Jin, Wangxun; Deng, Liming; Chen, Yunzhi; Chen, Bicheng; Li, Jianmin
2012-01-01
Current large animal models that could closely resemble the typical features of cirrhotic portal hypertension in human have not been well established. Thus, we aimed to develop and describe a reliable and reproducible canine cirrhosis model of portal hypertension. A total of 30 mongrel dogs were randomly divided into four groups: 1 (control; n = 5), 2 (portal vein stenosis [PVS]; n = 5], 3 (thioacetamide [TAA]; n = 5), and 4 (PVS plus TAA; n = 15). After 4-months modeling period, liver and spleen CT perfusion, abdominal CT scans, portal hemodynamics, gastroscopy, hepatic function, blood routine, the bone marrow, liver, and spleen histology were studied. The animals in group 2 (PVS) developed extrahepatic portosystemic collateral circulation, particularly esophageal varices, without hepatic cirrhosis and portal hypertension. Animals from group 3 (TAA) presented mild cirrhosis and portal hypertension without significant symptoms of esophageal varices and hypersplenism. In contrast, animals from group 4 (PVS + TAA) showed well-developed micronodular and macronodular cirrhosis, associated with significant portal hypertension and hypersplenism. The combination of PVS and TAA represents a novel, reliable, and reproducible canine cirrhosis model of portal hypertension, which is associated with the typical characteristics of portal hypertension, including hypersplenism.
Modeling qRT-PCR dynamics with application to cancer biomarker quantification.
Chervoneva, Inna; Freydin, Boris; Hyslop, Terry; Waldman, Scott A
2017-01-01
Quantitative reverse transcription polymerase chain reaction (qRT-PCR) is widely used for molecular diagnostics and evaluating prognosis in cancer. The utility of mRNA expression biomarkers relies heavily on the accuracy and precision of quantification, which is still challenging for low abundance transcripts. The critical step for quantification is accurate estimation of efficiency needed for computing a relative qRT-PCR expression. We propose a new approach to estimating qRT-PCR efficiency based on modeling dynamics of polymerase chain reaction amplification. In contrast, only models for fluorescence intensity as a function of polymerase chain reaction cycle have been used so far for quantification. The dynamics of qRT-PCR efficiency is modeled using an ordinary differential equation model, and the fitted ordinary differential equation model is used to obtain effective polymerase chain reaction efficiency estimates needed for efficiency-adjusted quantification. The proposed new qRT-PCR efficiency estimates were used to quantify GUCY2C (Guanylate Cyclase 2C) mRNA expression in the blood of colorectal cancer patients. Time to recurrence and GUCY2C expression ratios were analyzed in a joint model for survival and longitudinal outcomes. The joint model with GUCY2C quantified using the proposed polymerase chain reaction efficiency estimates provided clinically meaningful results for association between time to recurrence and longitudinal trends in GUCY2C expression.
[A treatment to serious esophageal cicatrices stenosi by metal and silica gel dilator].
Li, J; Chen, X; Sun, C; Liu, H
1999-12-01
To find an effective method of treating the esophageal cicatricial stenosis. Six cases with esophageal cicatricial stenosis were treated by mental and silica gel dilator. The effects in all six cases were satisfactory and no any complications were finded. The method is safe, effective and of no complications, the treatment time is shorter also.
Discrete subvalvular aortic stenosis in the Beckwith-Wiedemann syndrome.
Shirani, J; Natarajan, K; Varga, P; Vitullo, D A
1993-07-01
Various congenital cardiac malformations have been described in patients with Beckwith-Wiedemann (BW) syndrome, including reversible obstructive subaortic stenosis in one patient. We herein present a case of a 2.5-year-old black boy with BW syndrome and discrete subvalvular aortic stenosis of the membraneous type. Such association of these two entities has previously not been documented.
Corkscrew trachea: a novel type of congenital tracheal stenosis.
Bryant, Roosevelt; Morales, David L S
2009-06-01
The classic definition of congenital tracheal stenosis includes the presence of complete tracheal rings with absence of the membranous portion of the trachea. The morphologic type, based on Cantrell's classification, dictates the surgical management. In this report, we describe the presentation and surgical management of a novel type of distal congenital tracheal stenosis referred to as "corkscrew" trachea.
Arous, Edward J; Simons, Jessica P; Flahive, Julie M; Beck, Adam W; Stone, David H; Hoel, Andrew W; Messina, Louis M; Schanzer, Andres
2015-10-01
Carotid endarterectomy (CEA) for asymptomatic carotid artery stenosis is among the most common procedures performed in the United States. However, consensus is lacking regarding optimal preoperative imaging, carotid duplex ultrasound criteria, and ultimately, the threshold for surgery. We sought to characterize national variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic CEA. The Society for Vascular Surgery Vascular Quality Initiative (VQI) database was used to identify all CEA procedures performed for asymptomatic carotid artery stenosis between 2003 and 2014. VQI currently captures 100% of CEA procedures performed at >300 centers by >2000 physicians nationwide. Three analyses were performed to quantify the variation in (1) preoperative imaging, (2) carotid duplex ultrasound criteria, and (3) threshold for surgery. Of 35,695 CEA procedures in 33,488 patients, the study cohort was limited to 19,610 CEA procedures (55%) performed for asymptomatic disease. The preoperative imaging modality used before CEA varied widely, with 57% of patients receiving a single preoperative imaging study (duplex ultrasound imaging, 46%; computed tomography angiography, 7.5%; magnetic resonance angiography, 2.0%; cerebral angiography, 1.3%) and 43% of patients receiving multiple preoperative imaging studies. Of the 16,452 asymptomatic patients (89%) who underwent preoperative duplex ultrasound imaging, there was significant variability between centers in the degree of stenosis (50%-69%, 70%-79%, 80%-99%) designated for a given peak systolic velocity, end diastolic velocity, and internal carotid artery-to-common carotid artery ratio. Although 68% of CEA procedures in asymptomatic patients were performed for an 80% to 99% stenosis, 26% were performed for a 70% to 79% stenosis, and 4.1% were performed for a 50% to 69% stenosis. At the surgeon level, the range in the percentage of CEA procedures performed for a <80% asymptomatic carotid artery stenosis is from 0% to 100%. Similarly, at the center level, institutions range in the percentage of CEA procedures performed for a <80% asymptomatic carotid artery stenosis from 0% to 100%. Despite CEA being an extremely common procedure, there is widespread variation in the three primary determinants-preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery-of whether CEA is performed for asymptomatic carotid stenosis. Standardizing the approach to care for asymptomatic carotid artery stenosis will mitigate the significant downstream effects of this variation on health care costs. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Endovascular abdominal aortic stenosis treatment with the OptiMed self-expandable nitinol stent.
Ghazi, Payam; Haji-Zeinali, Ali-Mohammad; Shafiee, Nahid; Qureshi, Shakeel A
2009-10-01
To evaluate the safety and feasibility of self-expandable stents (OptiMed) for treatment of abdominal aortic stenosis in the situations in which the aortic stenosis locates near the origin of celiac, superior mesenteric, renal and inferior mesenteric arteries. Five consecutive patients scheduled for endovascular treatment of abdominal aortic stenosis by self-expandable nitinol stent (Sinus-Aorta/OptiMed) implantation. The diameter of the stent was chosen as 10-30% more than that of the normal portion of the aorta above the stenosis. Long stents of 60 mm or longer were chosen. After stent deployment, balloon postdilation was performed with a balloon in patients with residual gradient > 5 mm Hg. All patients were successfully treated with the OptiMed stents. The balloon predilation was performed in one patient due to severe stenosis. The mean diameter and length of the stents deployed were 20.4 +/- 2.9 (range, 16-24 mm) and 64 +/- 8.9 (range, 60-80 mm), respectively. The balloon postdilation was performed in all cases. The mean diameter of the balloons was 13.6 +/- 1.5 (range, 12-15 mm). The mean diameter of stenosis increased from 4.8 +/- 1.9 to 14.4 +/- 1.8 mm after stent placement. The mean peak systolic gradient decreased from 46.8 +/- 31.5 mm Hg to 0.8 +/- 1.8 mm Hg. During follow-up (22.8 +/- 14.3 months), none of the patients had restenosis within the stent, occlusion of any branches of the aorta, or other related complications. In our small series, we observed that abdominal aortic stenosis can be successfully and effectively treated with OptiMed stents in the situations in which the stenotic segment is located next to the origins of the main visceral branches of abdominal aorta.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saba, Luca, E-mail: lucasaba@tiscali.it; Sanfilippo, Roberto; Montisci, Roberto
Purpose: The purpose of this work was to determine whether it is possible to identify a reliable carotid stenosis threshold-measured in millimeters (mm)-that is associated with cerebrovascular symptoms. Methods: Written, informed consent was obtained for each patient; 149 consecutive patients (98 men; median age, 68 years) were studied for suspected pathology of the carotid arteries by using MDCTA. In each patient, carotid artery stenosis was quantified using the mm-method. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared by using the Student's t test. A ROC curve was calculated to test the studymore » hypothesis and identify a specific mm-stenosis threshold. Logistic regression analysis was performed to include other MDCTA findings, such as plaque type and ulcerations. A P value < 0.05 was considered to indicate statistical significance. Results: Twenty-six patients were excluded. Of those remaining, 75 patients suffered cerebrovascular symptoms (61%). There was a statistically significant difference (P = 0.0046) in the mm-carotid stenosis between patients with symptoms (1.31 {+-} 0.64 mm SD) and without symptoms (1.68 {+-} 0.79 mm SD). Multiple logistic regression analysis confirmed that symptoms were associated with increased luminal stenosis (P = 0.013) and with the presence of fatty plaques (P = 0.0491). Moreover, the ROC curve (Az = 0.669; {+-}0.051 SD; P = 0.0009) indicated that a threshold of 1.6 mm stenosis was associated with a sensitivity to symptoms of 76%. Conclusions: The results of our study suggest an association between luminal stenosis (measure in mm) and the presence of cerebrovascular symptoms. Luminal stenosis of 1.6 mm is associated, with a sensitivity of 76%, with cerebrovascular symptoms.« less
Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li
2017-09-01
The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis <50%) and thirty gender- and age-matched patients (control group) without coronary artery stenosis according to the coronary angiogram results were prospectively enrolled. All the patients had no left ventricular regional wall motion abnormality in two-dimensional echocardiography at rest and exercise stress. There was no significant difference in the 16 segmental systolic peak AS at rest between two groups. After exercise stress, the peak systolic AS rest-stress at mid anterior wall (-7.00%±10.90% vs 2.80%±23.69%) and mid anterolateral wall (-4.40%±18.81% vs 8.80%±19.16%) were decreased, while increased at basal inferolateral wall (14.00%±19.27% vs -5.60%±15.94%) in case group compared with control group (P<.05). In patients with mild single vessel coronary artery stenosis, the area strain was decreased at involved segments, while compensatory increased at noninvolved segments after exercise stress. Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.
Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.
Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal
2014-07-01
We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zhao, Hai-Yan; Han, Jin-Tao; Fan, Dong-Sheng
2017-09-01
To analyze the incidence of intracranial unruptured aneurysms in patients with intracranial artery stenosis,clinical features,and investigate the risk factors for unruptured intracranial aneurysms. Medical records from all patients performed with digital subtraction angiography (DSA) who had been treated at Peking University Third Hospital,China,from January 2012 to December 2015 were retrospectively reviewed to identify cases coexistence with cerebral artery stenosis and unruptured intracranial aneurysm. Of 273 patients with cerebral artery stenosis (≥50%),intracranial unruptured aneurysms was observed in 17 cases (6.23%) from age of 45 to 78,among them 8 (47.06%) were female and 9 (52.94%) were male. The incidence of unruptured intracranial aneurysm in male patients was 4.17% (9/216),and that of female was 14.4% (8/57). There was statistically significant difference between the male and female incidence of intracranial aneurysm ( P <0.05). Of these 17 patients,16 (94.12%) aneurysms were located in the internal carotid artery (ICA) system,1 (5.88%) aneurysm was located at the tip of the basilar artery. In 11 cases (64.71%),aneurysms were located at the distal of the stenotic vessels,2 (11.76%) were located at the proximal of the stenotic vessels,and 4 cases (23.53%) of which the aneurysm and stenosis were not in the same artery. Logistic multivariate analysis showed that gender was an independent risk factor for aneurysms in patients with cerebral arterial stenosis. In the intracranial artery stenosis atients,the possibility of the occurrence of the aneurysm is much higher than the general population,and women were more prominent than man. Sex is an independent risk factor for aneurysms in patients with cerebral arterial stenosis.
Significant Coronary Stenosis in Asymptomatic Chinese With Different Glycemic Status
Xu, Yu; Bi, Yufang; Li, Mian; Wang, Tiange; Sun, Kun; Xu, Min; Lu, Jieli; Yu, Yi; Li, Xiaoying; Lai, Shenghan; Wang, Weiqing; Ning, Guang
2013-01-01
OBJECTIVE To evaluate coronary artery stenosis in early diabetes or prediabetes asymptomatic of myocardial ischemia in community-dwelling Chinese adults. RESEARCH DESIGN AND METHODS Age- and sex-matched participants with normal glucose regulation (NGR), prediabetes, or diabetes diagnosed within 5 years, asymptomatic of coronary artery disease (CAD), were randomly selected from a community-dwelling Chinese population aged 40–60 years. Dual-source computed tomography coronary angiography was used to evaluate the existence and extent of coronary stenosis, which was considered significant if >50% narrowing of vessel lumen was detected. RESULTS After excluding uninterpretable segments attributable to motion artifacts, a total of 135 participants with NGR, 132 with prediabetes, and 134 with diabetes participated in data analysis. Significant coronary stenosis was detected in 10 (7.4%), 10 (7.6%), and 22 (16.4%) individuals with NGR, prediabetes, and diabetes, respectively (P for trend = 0.029). Diabetes, rather than prediabetes, was associated with a significant 2.34-fold elevated risk [odds ratio (OR) 2.34 (95% CI 1.01–5.43); P = 0.047] of significant coronary stenosis as compared with that associated with NGR. Levels of glucose evaluation were independently and significantly associated with risks of significant coronary stenosis in diabetes. Each 1-SD increase in fasting plasma glucose, 2-h postload plasma glucose, and HbA1c conveyed 2.11-fold, 1.73-fold, and 1.81-fold higher risks of significant coronary stenosis, respectively, after adjustment for other conventional cardiovascular risk factors. CONCLUSIONS Using a noninvasive CAD diagnostic modality such as dual-source computed tomography coronary angiography, we detected a markedly elevated risk of significant coronary stenosis with early diabetes in asymptomatic Chinese adults. PMID:23462666
Cervical spinal stenosis and sports-related cervical cord neurapraxia in children.
Boockvar, J A; Durham, S R; Sun, P P
2001-12-15
Congenital spinal stenosis has been demonstrated to contribute to cervical cord neurapraxia after cervical spinal cord injury in adult athletes. A sagittal canal diameter <14 mm and/or a Torg ratio (sagittal diameter of the spinal canal: midcervical sagittal vertebral body diameter) of <0.8 are indicative of significant cervical spinal stenosis. Although sports-related cervical spine injuries are common in children, the role of congenital cervical stenosis in the etiology of these injuries remains unclear. The authors measured the sagittal canal diameter and the Torg ratio in children presenting with cervical cord neurapraxia resulting from sports-related cervical spinal cord injuries to determine the presence of congenital spinal stenosis. A total of 13 children (9 male, 4 female) presented with cervical cord neurapraxia after a sports-related cervical spinal cord injury. Age ranged from 7 to 15 years (mean +/- SD, 11.5 +/- 2.7 years). The sports involved were football (n = 4), wrestling (n = 2), hockey (n = 2), and soccer, gymnastics, baseball, kickball, and pogosticking (n = 1 each). Lateral cervical spine radiographs were used to determine the sagittal canal diameter and the Torg ratio at C4. The sagittal canal diameter (mean +/- SD, 17.58 +/- 1.63 mm) and the Torg ratio (mean +/- SD, 1.20 +/- 0.24) were normal in all of these children. Using the sagittal canal diameter and the Torg ratio as a measurement of congenital spinal stenosis, the authors did not find evidence of congenital cervical spinal stenosis in a group of children with sports-related cervical spinal cord neurapraxia. The occurrence of cervical cord neurapraxia in pediatric patients can be attributed to the mobility of the pediatric spine rather than to congenital cervical spinal stenosis.
Maycock, Matthew I; Farman, Colin; Mort, Alasdair; Turpie, David; Leslie, Stephen J
2013-01-01
Calcific aortic stenosis is the most common cardiac valve lesion and is becoming increasingly prevalent as life expectancy rises. There is evidence that patients in remote and rural areas with certain diseases have worse outcomes and present to specialist services later than their urban counterparts. It is not known whether patients with aortic stenosis follow a similar pattern. The aim of this study was to investigate whether increasing rurality was associated with later presentation to healthcare services at a more advanced stage of aortic stenosis. This was a retrospective cohort study. Using ICD-10 discharge codes and local databases, 605 patients with aortic stenosis who presented between 31 November 1999 and 1 December 2008 were identified. Aortic stenosis was defined as a pressure gradient across the aortic valve of 25 mmHg or more. Patients with prior aortic valve replacement were excluded. Clinical notes were reviewed for all patients. Gender, age and pressure gradient across the aortic valve at presentation and patient GP-practice location were recorded. Patients were then assigned a Clinical Peripherality Index score based on the postcode of their GP's practice to define rurality. Patient data were compared across the six defined levels of clinical peripherality by ANOVA. Mean patient age was 73 ± 13 years, and 336 (54%) were male. The peak gradient across the valve was 41.1 ± 26.7 mmHg. There was no association between the level of clinical peripherality and the stage of aortic stenosis at presentation, age or gender (all p >0.05). There was no urban-rural gradient in the severity of aortic stenosis at presentation in this remote Scottish cohort. This suggests that patients with this condition in remote areas do not present later in their disease trajectory.
Marawar, Satyajit V; Madom, Ian A; Palumbo, Mark; Tallarico, Richard A; Ordway, Nathaniel R; Metkar, Umesh; Wang, Dongliang; Green, Adam; Lavelle, William F
2017-01-01
Treating surgeon's visual assessment of axial MRI images to ascertain the degree of stenosis has a critical impact on surgical decision-making. The purpose of this study was to prospectively analyze the impact of surgeon experience on inter-observer and intra-observer reliability of assessing severity of spinal stenosis on MRIs by spine surgeons directly involved in surgical decision-making. Seven fellowship trained spine surgeons reviewed MRI studies of 30 symptomatic patients with lumbar stenosis and graded the stenosis in the central canal, the lateral recess and the foramen at T12-L1 to L5-S1 as none, mild, moderate or severe. No specific instructions were provided to what constituted mild, moderate, or severe stenosis. Two surgeons were "senior" (>fifteen years of practice experience); two were "intermediate" (>four years of practice experience), and three "junior" (< one year of practice experience). The concordance correlation coefficient (CCC) was calculated to assess inter-observer reliability. Seven MRI studies were duplicated and randomly re-read to evaluate inter-observer reliability. Surgeon experience was found to be a strong predictor of inter-observer reliability. Senior inter-observer reliability was significantly higher assessing central(p<0.001), foraminal p=0.005 and lateral p=0.001 than "junior" group.Senior group also showed significantly higher inter-observer reliability that intermediate group assessing foraminal stenosis (p=0.036). In intra-observer reliability the results were contrary to that found in inter-observer reliability. Inter-observer reliability of assessing stenosis on MRIs increases with surgeon experience. Lower intra-observer reliability values among the senior group, although not clearly explained, may be due to the small number of MRIs evaluated and quality of MRI images.Level of evidence: Level 3.
Exertional dyspnea as a symptom of infrarenal aortic occlusive disease.
Schott, Stacey L; Carreiro, Fernanda Porto; Harkness, James R; Malas, Mahmoud B; Sozio, Stephen M; Zakaria, Sammy
2014-06-01
Advanced atherosclerosis of the aorta can cause severe ischemia in the kidneys, refractory hypertension, and claudication. However, no previous reports have clearly associated infrarenal aortic stenosis with shortness of breath. A 77-year-old woman with hypertension and hyperlipidemia presented with exertional dyspnea. Despite extensive testing and observation, no apparent cause for this patient's dyspnea was found. Images revealed severe infrarenal aortic stenosis. After the patient underwent stenting of the aortic occlusion, she had immediate symptomatic improvement and complete resolution of her dyspnea within one month. Twelve months after vascular intervention, the patient remained asymptomatic. In view of the distinct and lasting elimination of dyspnea after angioplasty and stenting of a nearly occluded infrarenal aortic lesion, we hypothesize that infrarenal aortic stenosis might be a treatable cause of exertional dyspnea. Clinicians should consider infrarenal aortic stenosis as a possible cause of dyspnea. Treatment of the stenosis might relieve symptoms.
Yokoyama, Shinya; Nagato, Hisao; Yoshida, Yuichi; Nagasaka, Shigeo; Kaneda, Kozo; Nishiwaki, Noboru
2016-01-16
Although repair of a supravalvular aortic stenosis (SVAS) can be performed with low mortality rates, surgery for the complex form of SVAS continues to be associated with a high incidence of residual stenosis. The patient was referred to our hospital at 1 month of age and was diagnosed with aortic valve stenosis (AS) by using echocardiography. Cardiac catheterization revealed moderate AS, and subsequent left ventriculography revealed discrete stenosis of the sino-tubular junction and a narrowed proximal ascending aorta. We performed a reconstructive operation for such heart defects involving novel three-sinus and ascending aorta enlargement without aortic root transection in a 6-month-old boy. Our novel three-sinus enlargement technique is suitable for treating each type of SVAS and is a useful method for a baby particularly less than 10 kg without disturbing the growth of the ascending aorta.
Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L
2010-01-01
Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.
Cuestas, Giselle; Rodríguez, Verónica; Doormann, Flavia; Pringe, Alejandra; Bellia Munzón, Patricio; Bellia Munzón, Gastón; Ortega, Carlos; Álvarez, Rubén
2017-04-01
Wegener's granulomatosis is a necrotizing granulomatous vasculitis of autoimmune origin that primarily affects the upper and lower airways and kidneys. It is very rare in children and adolescents. When started at a young age it is often associated with subglottic stenosis. Subglottic stenosis is a potentially fatal manifestation of Wegener's granulomatosis. Its diagnosis requires a high index of suspicion since it might develop in the absence of other signs of activity. Occasionally, subglottic stenosis may present as the initial manifestation of the disease. Diagnosis is confirmed by endoscopic visualization of the lesion. The treatment is complex, and it often requires repeated interventions due to restenosis. We present a 13-year-old patient with subglottic stenosis secondary to Wegener's granulomatosis. We describe the clinical manifestations, diagnosis and treatment of this rare cause of respiratory distress in the pediatric population. Sociedad Argentina de Pediatría.
Lin, Xiaoxiao; Ye, Min; Li, Yuping
2018-01-01
Upper tracheal stenosis is considered as a potentially life-threatening condition. Silicone stenting is an attractive treatment option for patients with upper tracheal stenosis. However, its use has been compromised by a major complication, stent migration. In the report, we introduced a novel external fixation of silicone stent which only needed one puncture site and involved a silicon chip as an anchoring device. All equipment and materials including the silicon chip were available in routine bronchoscopy suite. The method had been successfully performed in three patients with upper tracheal stenosis at our institution. And the patients were monitored for over 20 months after the intervention, and no spontaneous stent migration occurred. Therefore, we believe this is a simple and reliable approach for improving the outcome of silicone stenting in patients with upper tracheal stenosis and should be introduced in clinical practice.
Séguin, Bernard; Steinke, Julia R
2016-04-01
To describe a technique using labial mucosal flaps to correct stenosis of the nares subsequent to bilateral rostral maxillectomy and nasal planum resection. Case report Client-owned dog. A 10-year-old, neutered male Golden Retriever developed repeated stenosis of the nares, at first after bilateral rostral maxillectomy and nasal planum resection, and again after revision surgery. Bilateral, superior labial mucosal transposition flaps were created and interpolated between the nasal mucosa and skin after debridement of scar tissue. The stenosis did not recur after mucosal flap transposition and the dog returned to normal quality of life (last follow-up 25 months postoperative). Single-stage, superior labial mucosal transposition flaps can be used to correct nares stenosis subsequent to previous surgery. © Copyright 2016 by The American College of Veterinary Surgeons.
[ENDOSONOGRAPHY IN THE DIFFERENTIAL DIAGNOSIS OF THE COMMON BILE DUCT STENOSIS].
Solodinina, E N; Starkov, Y G; Shumkin, L V
2015-01-01
The article states the results of examination and treatment of 57 patients with stenosis of the common bile duct of various genesis. The main aim of the work is criteria definition and evaluation of diagnostic significance of endosonography in the differential diagnosis of benign and malignant common bile duct stenosis. The paper presents a methodology of endoscopic ultrasound and basic criteria for the differential diagnosis of tumors and other lesions of the extrahepatic bile ducts. A comparative analysis of endosonography, ultrasound, CT, MRCP was conducted. The sensitivity of endosonography in determining the nature of the common bile duct stenosis was 97.7%, a specificity 100% and accuracy 98.2%, which is superior to other methods of radiological diagnosis. In comprehensive surgical centers endosonography should be used as a method of specifying the final diagnosis to determine the nature of the common bile duct stenosis, particularly at low constriction location.
Conservative treatment of esophageal perforation related to a peptic ulcer with pyloric stenosis.
Tanaka, Ryo; Kosugi, Shin-Ichi; Sato, Daisuke; Hirukawa, Hiroshi; Tada, Tetsuya; Ichikawa, Hiroshi; Hanyu, Takaaki; Ishikawa, Takashi; Kobayashi, Takashi; Wakai, Toshifumi
2014-08-01
We report a case of esophageal perforation (Boerhaave syndrome) caused by vomiting related to a duodenal ulcer with pyloric stenosis. A 45-year-old male presented with left chest pain and dyspnea after forceful vomiting. Chest radiography and computed tomography (CT) revealed a massive left pleural effusion and left tension pneumothorax. Abdominal CT revealed pyloric stenosis with a remarkably dilated stomach. Tube thoracostomy and nasogastric suction were immediately performed and we selected conservative treatment based on the following factors-a stable general condition without sepsis, early diagnosis, and good drainage. Esophagogastroduodenoscopy on hospital day 9 demonstrated a healing ulcer in the lower esophagus and pyloric stenosis. We performed distal gastrectomy as elective surgery for pyloric stenosis due to a duodenal ulcer on hospital day 30. In summary, an esophageal perforation with contamination spreading to the thoracic cavity was successfully treated with conservative treatment.
Congenital esophageal stenosis owing to tracheobronchial remnants
Rebelo, Priscila Guyt; Ormonde, João Victor C.; Ormonde, João Baptista C.
2013-01-01
OBJECTIVE To emphasize the need of an accurate diagnosis of congenital esophageal stenosis due to tracheobronchial remnants, since its treatment differs from other types of congenital narrowing. CASE DESCRIPTION Four cases of lower congenital esophageal stenosis due to tracheobronchial remnants, whose definitive diagnosis was made by histopathology. Except for the last case, in which a concomitant anti-reflux surgery was not performed, all had a favorable outcome after resection and anastomosis of the esophagus. COMMENTS The congenital esophageal stenosis is an intrinsic narrowing of the organâ€(tm)s wall associated with its structural malformation. The condition can be caused by tracheobronchial remnants, fibromuscular stenosis or membranous diaphragm and the first symptom is dysphagia after the introduction of solid food in the diet. The first-choice treatment to tracheobronchial remnants cases is the surgical resection and end-to-end anastomosis of the esophagus. PMID:24142326
Spilker, Ryan L; Feinstein, Jeffrey A; Parker, David W; Reddy, V Mohan; Taylor, Charles A
2007-04-01
Patient-specific computational models could aid in planning interventions to relieve pulmonary arterial stenoses common in many forms of congenital heart disease. We describe a new approach to simulate blood flow in subject-specific models of the pulmonary arteries that consists of a numerical model of the proximal pulmonary arteries created from three-dimensional medical imaging data with terminal impedance boundary conditions derived from linear wave propagation theory applied to morphometric models of distal vessels. A tuning method, employing numerical solution methods for nonlinear systems of equations, was developed to modify the distal vasculature to match measured pressure and flow distribution data. One-dimensional blood flow equations were solved with a finite element method in image-based pulmonary arterial models using prescribed inlet flow and morphometry-based impedance at the outlets. Application of these methods in a pilot study of the effect of removal of unilateral pulmonary arterial stenosis induced in a pig showed good agreement with experimental measurements for flow redistribution and main pulmonary arterial pressure. Next, these methods were applied to a patient with repaired tetralogy of Fallot and predicted insignificant hemodynamic improvement with relief of the stenosis. This method of coupling image-based and morphometry-based models could enable increased fidelity in pulmonary hemodynamic simulation.
Zhong, Chunyan; Guo, Yanli; Huang, Haiyun; Tan, Liwen; Wu, Yi; Wang, Wenting
2013-01-01
To establish 3D models of coronary arteries (CA) and study their application in localization of CA segments identified by Transthoracic Echocardiography (TTE). Sectional images of the heart collected from the first CVH dataset and contrast CT data were used to establish 3D models of the CA. Virtual dissection was performed on the 3D models to simulate the conventional sections of TTE. Then, we used 2D ultrasound, speckle tracking imaging (STI), and 2D ultrasound plus 3D CA models to diagnose 170 patients and compare the results to coronary angiography (CAG). 3D models of CA distinctly displayed both 3D structure and 2D sections of CA. This simulated TTE imaging in any plane and showed the CA segments that corresponded to 17 myocardial segments identified by TTE. The localization accuracy showed a significant difference between 2D ultrasound and 2D ultrasound plus 3D CA model in the severe stenosis group (P < 0.05) and in the mild-to-moderate stenosis group (P < 0.05). These innovative modeling techniques help clinicians identify the CA segments that correspond to myocardial segments typically shown in TTE sectional images, thereby increasing the accuracy of the TTE-based diagnosis of CHD.
Maurovich-Horvat, Pál; Tárnoki, Dávid L; Tárnoki, Ádám D; Horváth, Tamás; Jermendy, Ádám L; Kolossváry, Márton; Szilveszter, Bálint; Voros, Viktor; Kovács, Attila; Molnár, Andrea Á; Littvay, Levente; Lamb, Hildo J; Voros, Szilard; Jermendy, György; Merkely, Béla
2015-12-01
The heritability of coronary atherosclerotic plaque burden, coronary geometry, and phenotypes associated with increased cardiometabolic risk are largely unknown. The primary aim of the Burden of Atherosclerotic Plaques Study in Twins-Genetic Loci and the Burden of Atherosclerotic Lesions (BUDAPEST-GLOBAL) study is to evaluate the influence of genetic and environmental factors on the burden of coronary artery disease. By design this is a prospective, single-center, classical twin study. In total, 202 twins (61 monozygotic pairs, 40 dizygotic same-sex pairs) were enrolled from the Hungarian Twin Registry database. All twins underwent non-contrast-enhanced computed tomography (CT) for the detection and quantification of coronary artery calcium and for the measurement of epicardial fat volumes. In addition, a single non-contrast-enhanced image slice was acquired at the level of L3-L4 to assess abdominal fat distribution. Coronary CT angiography was used for the detection and quantification of plaque, stenosis, and overall coronary artery disease burden. For the primary analysis, we will assess the presence and volume of atherosclerotic plaques. Furthermore, the 3-dimensional coronary geometry will be assessed based on the coronary CT angiography datasets. Additional phenotypic analyses will include per-patient epicardial and abdominal fat quantity measurements. Measurements obtained from monozygotic and dizygotic twin pairs will be compared to evaluate the genetic or environmental effects of the given phenotype. The BUDAPEST-GLOBAL study provides a unique framework to shed some light on the genetic and environmental influences of cardiometabolic disorders. © 2015 Wiley Periodicals, Inc.
Tight Left Upper Lobe Collapse from Lung Cancer
2010-07-01
misinterpreted or overlooked on chest radiographs. In reviewing lobar collapse, a typical cause is from proximal occlusion or stenosis of a lobar...common causes include fibrotic stenosis from granulomatous disease, post- radiation bronchial stenosis , and inflammatory conditions (eg. polychondritis...pleural space. On frontal radiograph, a cresentic hyperlucency may be noted adjacent to the thoracic aortic arch in about half of cases
Valente, Acrisio Sales; Alencar, Polyanna; Santos, Alana Neiva; Lobo, Roberto Augusto de Mesquita; de Mesquita, Fernando Antônio; Guimarães, Aloyra Guedis
2013-01-01
The supravalvular aortic stenosis is a rare congenital heart defect being very uncommon in adults. We present a case of supravalvular aortic stenosis in adult associated with anomalies of the aortic arch vessels and aortic regurgitation, which was submitted to aortic valve replacement and arterioplasty of the ascending aorta with a good postoperative course. PMID:24598962
Mitral stenosis and percutaneous mitral valvuloplasty (part 1).
Guérios, Enio E; Bueno, Ronaldo; Nercolini, Deborah; Tarastchuk, José; Andrade, Paulo; Pacheco, Alvaro; Faidiga, Alysson; Negrao, Stefan; Barbosa, Antonio
2005-07-01
Although the incidence and severity of rheumatic mitral stenosis have declined in developed countries, the disease is still highly prevalent in many of the poorer and most densely populated areas of the globe, remaining a major public health issue and reflecting the socioeconomic status of the region. In the last 30 years, mitral stenosis therapy has undergone a reorientation with the introduction of percutaneous mitral valvuloplasty. This manuscript is an updated review of percutaneous dilation of mitral stenosis in its different aspects, encompassing traditional techniques, technical innovations, the most significant case loads worldwide, an analysis of the procedure as well as immediate and late outcomes.
[Congenital stenosis of interventricular foramina revealed by recurrent intracranial hypertension].
Ben Achour, N; Kraoua, I; Rouissi, A; Benrhouma, H; Ben Youssef-Turki, I; Jemel, H; Gouider-Khouja, N
2013-04-01
Non-tumoral stenosis of interventricular foramen is a rare clinical condition. It can be either unilateral, causing monoventricular hydrocephalus, or bilateral leading to biventricular hydrocephalus. The pathophysiology of this misdiagnosed entity remains controversial. The non-tumoral stenosis of interventricular foramen can be either acquired or congenital. The latter usually manifesting with a neonatal hydrocephalus. We report a case of congenital bilateral stenosis of interventricular foramen, in an 8-year-old girl, revealed by recurrent intracranial hypertension. Diagnosis was relied on 3D-CISS sequences MRI. The child showed full recovery after neuroendoscopic septal fenestration and ventriculo-peritoneal shunt. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Carotid Artery Stenting: Review of Technique and Update of Recent Literature
Ahn, Sun Ho; Prince, Ethan A.; Dubel, Gregory J.
2013-01-01
Stroke is the fourth leading cause of death and the number one cause of long-term disability in the United States. Carotid stenosis is an important cause of ischemic strokes, accounting for 20 to 25%. Previous studies have established carotid endarterectomy as standard of care of symptomatic patients with > 50% stenosis and asymptomatic patients with > 60% stenosis; recently, carotid artery stenting has emerged as an alternative treatment for carotid stenosis. Several studies have been published comparing carotid artery stenting with endarterectomy with mixed results. In this article, the authors discuss carotid artery stenting technique, the results from the most recent trials, and future directions. PMID:24436551
Kwon, Jang Hoon; Han, Koon Hee; Kim, Moon Ho; Jang, Woo Sung; Yun, Jung Ho; Song, Yun A; Park, Jong Kyu; Cheon, Gab Jin
2014-09-25
Anastomotic stenosis of the colon is not an uncommon finding; however, its frequency varies from one study to another. Traditionally, postoperative colonic stenosis is managed surgically. However, endoscopic therapy has recently become the preferred treatment modality over traditional surgery. Good short-term success has been achieved with use of endoscopic balloon dilation; however, restenosis may occur over time in 14% to 25% of patients. The current report showed the effectiveness and usefulness of an insulated-tip knife (IT-knife) for electrocautery therapy of a patient with symptomatic anastomotic colonic stenosis.
Clinical application of the Natural Y stent in the management of benign carinal stenosis.
Nam, Hae-Seong; Um, Sang Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung; Kim, Jhingook; Kim, Hojoong
2009-08-01
The Y-shaped structure of the carinal bifurcation causes difficulties in the treatment of carinal stenosis. We describe a new Y-shaped silicone stent, called the Natural Y stent. We investigated its clinical efficacy through a review of patients with benign carinal stenosis who undewent consecutive Natural Y stent placement. Between January 2004 and February 2008, 11 patients underwent ballooning, neodymium:yttrium-aluminum-garnet laser resection, or bougienation (by rigid bronchoscopy) to dilate the airway, followed by placement of the Natural Y stent. The underlying etiologies of carinal stenosis included posttuberculosis stricture in 7 patients (64%), postintubation stenosis in 2 (18%), and postoperative malacia in 2 (18%). All patients reported subjective symptomatic relief immediately after stent placement. No procedurally related deaths or immediate major complications occurred. Stent-related late complications included granulation tissue formation (64%) and mucostasis (18%, defined as > or = 50% narrowing). The median duration of overall stent placement was 439 days (range, 119 to 1729 days). The stents were successfully removed in 4 patients (36%) after a median of 409 days. The Natural Y stent provides an effective and feasible therapeutic modality in patients with benign carinal stenosis, with or without previous thoracic airway interventions.
Nakaegawa, Yuta; Nakamura, Ryosuke; Tada, Yasuhiro; Suzuki, Ryo; Takezawa, Toshiaki; Nakamura, Tatsuo; Omori, Koichi
2017-06-01
Tight fixation of the artificial trachea is important for epithelialization and tracheal stenosis. The authors have developed an artificial trachea and have used it for tracheal reconstruction. Although various studies on tracheal reconstruction have been conducted, no studies have examined the effect of artificial tracheal fixation on tracheal stenosis and regeneration. Therefore, the purpose of the present study was to evaluate the effect of artificial tracheal fixation. Preliminary animal experiment. Artificial tracheae were implanted into rabbits with partial tracheal defects. Tracheal stenosis and regeneration of the tracheal epithelium on the artificial tracheae were evaluated by endoscopic examination, scanning electron microscopic analysis, and histological examination. The artificial tracheae fixed to the tracheal defects were classified into three groups (0-point, 4-point, and 8-point) by the number of fixation points. At 14 and 28 days post-implantation, the luminal surface of the implantation area was mostly covered with epithelium in all fixation groups. However, a small amount of granulation tissue was observed in the 0-point fixation group at 14 days post-implantation. Moreover, tracheal stenosis did not occur in the 8-point fixation group, but stenosis was detected in the other groups.
Sakai, Yoshihito
2012-04-01
Lumbar canal stenosis most commonly affects the elderly population by entrapment of the cauda equine roots surrounding the spinal canal often associated with pain in the back and lower extremities, difficulty ambulating. The locomotive syndrome refers to high-risk conditions under requiring care services, and lumbar canal stenosis is an important underlying disease. As one of the key capacities of frailty identified muscluloskeletal function, the locomotive syndrome is considered to musculoskeletal frail syndrome. Surgical treatment should be recommended to take the pressure off the nerves in the lumbar spine when the conservative treatments failed, and several studies revealed that the surgery generally resulted in a preferable outcome in the lumbar canal stenosis patients. Among lumbar canal stenosis patients treated with surgery, locomotive syndrome was contained 44% and many of which were seen in thin females. The patients with locomotive syndrome had lower muscle volume both in the extremities and the trunk than those without locomotive syndrome, and surgical results were poorer in the activity of daily life whereas the pain relief was adequately obtained. Treatment of the lumbar canal stenosis should be attended to locomotive frailty, and muscle strengthening training should be incorporated into pre and postoperative therapy.
Xu, Xuan; Li, Dandan; Zhao, Shuyu; Liu, Xicheng; Feng, Zhichun; Ding, Hui
2012-01-01
The aim of this study was to evaluate the use of balloon-expandable metallic stents in the treatment of children with congenital tracheal stenosis in whom conventional therapy has failed. From 2010 to 2011, balloon-expandable metallic stents were implanted into the trachea of eight infants aged 2–20 months in the paediatric intensive care unit. The infants had severe airway obstruction caused by congenital tracheal stenosis. Tracheal stents were placed after intraluminal balloon dilatation of the tracheal stenosis, inserted with balloon catheters and implanted into the desired position bronchoscopically. The stents were 12 to 29 mm long and 4 mm in diameter. Seven children were relieved of airway obstruction after this procedure. However, a child died due to severe sepsis after the placement of bronchial stents. No granulation tissue developed over the stents in any of the children. Stents have been in place for 1–6 months after insertion without any other complication. Balloon-expandable metallic stents are effective in relieving airway obstruction by congenital tracheal stenosis in children. This technique may provide an important remedy for congenital tracheal stenosis in children. PMID:22361127
Prevalence of pharyngeal and esophageal stenosis following radiation for head and neck cancer.
Nguyen, Nam P; Smith, Herbert J; Moltz, Candace C; Frank, Cheryl; Millar, Carrie; Dutta, Suresh; Lee, Howard; North, Debra; Karlsson, Ulf; Vos, Paul; Nguyen, Ly M; Sallah, Sabah
2008-04-01
To evaluate the risk and outcome of pharyngoesophageal stenosis in patients who complained of dysphagia following radiation for head and neck cancer. Retrospective study. Veterans Administration hospital. Patients who complained of persistent dysphagia following radiation alone or combined with surgery or chemotherapy for head and neck cancer. Patients were selected if they were cancer free at the time of the swallowing study. All patients had modified barium swallow (MBS) and an endoscopic examination for initial evaluation of their dysphagia. Traditional barium swallow was requested when there was a suspicion of pharyngoesophageal stenosis on MBS. Two hundred twenty-two patients underwent MBS for evaluation of dysphagia posttreatment. Traditional barium swallow confirmed the diagnosis of pharyngeal (n = 2) or esophageal (n = 14) stenosis in 16 patients. Eight patients had esophageal stenosis on endoscopic examination. All patients underwent dilatation for relief of their dysphagia. The number of dilatations performed was, respectively, one in 12 patients, two in 4 patients, three in 3 patients, four in 3 patients, five in one patient, and six in one patient. Pharyngeal and/or cervical esophageal stenosis may be the cause of dysphagia following radiation for head and neck cancer. Esophageal dilatations often offer temporary relief of the dysphagia.
Mor-Avi, Victor; Patel, Mita B; Maffessanti, Francesco; Singh, Amita; Medvedofsky, Diego; Zaidi, S Javed; Mediratta, Anuj; Narang, Akhil; Nazir, Noreen; Kachenoura, Nadjia; Lang, Roberto M; Patel, Amit R
2018-06-01
Combined evaluation of coronary stenosis and the extent of ischemia is essential in patients with chest pain. Intermediate-grade stenosis on computed tomographic coronary angiography (CTCA) frequently triggers downstream nuclear stress testing. Alternative approaches without stress and/or radiation may have important implications. Myocardial strain measured from echocardiographic images can be used to detect subclinical dysfunction. The authors recently tested the feasibility of fusion of three-dimensional (3D) echocardiography-derived regional resting longitudinal strain with coronary arteries from CTCA to determine the hemodynamic significance of stenosis. The aim of the present study was to validate this approach against accepted reference techniques. Seventy-eight patients with chest pain referred for CTCA who also underwent 3D echocardiography and regadenoson stress computed tomography were prospectively studied. Left ventricular longitudinal strain data (TomTec) were used to generate fused 3D displays and detect resting strain abnormalities (RSAs) in each coronary territory. Computed tomographic coronary angiographic images were interpreted for the presence and severity of stenosis. Fused 3D displays of subendocardial x-ray attenuation were created to detect stress perfusion defects (SPDs). In patients with stenosis >25% in at least one artery, fractional flow reserve was quantified (HeartFlow). RSA as a marker of significant stenosis was validated against two different combined references: stenosis >50% on CTCA and SPDs seen in the same territory (reference standard A) and fractional flow reserve < 0.80 and SPDs in the same territory (reference standard B). Of the 99 arteries with no stenosis >50% and no SPDs, considered as normal, 19 (19%) had RSAs. Conversely, with stenosis >50% and SPDs, RSAs were considerably more frequent (17 of 24 [71%]). The sensitivity, specificity, and accuracy of RSA were 0.71, 0.81, and 0.79, respectively, against reference standard A and 0.83, 0.81, and 0.82 against reference standard B. Fusion of CTCA and 3D echocardiography-derived resting myocardial strain provides combined displays, which may be useful in determination of the hemodynamic or functional impact of coronary abnormalities, without additional ionizing radiation or stress testing. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Venous sinus stenting for reduction of intracranial pressure in IIH: a prospective pilot study.
Liu, Kenneth C; Starke, Robert M; Durst, Christopher R; Wang, Tony R; Ding, Dale; Crowley, R Webster; Newman, Steven A
2017-11-01
OBJECTIVE Idiopathic intracranial hypertension (IIH) may cause blindness due to elevated intracranial pressure (ICP). Venous sinus stenosis has been identified in select patients, leading to stenting as a potential treatment, but its effects on global ICP have not been completely defined. The purpose of this pilot study was to assess the effects of venous sinus stenting on ICP in a small group of patients with IIH. METHODS Ten patients for whom medical therapy had failed were prospectively followed. Ophthalmological examinations were assessed, and patients with venous sinus stenosis on MR angiography proceeded to catheter angiography, venography with assessment of pressure gradient, and ICP monitoring. Patients with elevated ICP measurements and an elevated pressure gradient across the stenosis were treated with stent placement. RESULTS All patients had elevated venous pressure (mean 39.5 ± 14.9 mm Hg), an elevated gradient across the venous sinus stenosis (30.0 ± 13.2 mm Hg), and elevated ICP (42.2 ± 15.9 mm Hg). Following stent placement, all patients had resolution of the stenosis and gradient (1 ± 1 mm Hg). The ICP values showed an immediate decrease (to a mean of 17.0 ± 8.3 mm Hg), and further decreased overnight (to a mean of 8 ± 4.2 mm Hg). All patients had subjective and objective improvement, and all but one improved during follow-up (median 23.4 months; range 15.7-31.6 months). Two patients developed stent-adjacent stenosis; retreatment abolished the stenosis and gradient in both cases. Patients presenting with papilledema had resolution on follow-up funduscopic imaging and optical coherence tomography (OCT) and improvement on visual field testing. Patients presenting with optic atrophy had optic nerve thinning on follow-up OCT, but improved visual fields. CONCLUSIONS For selected patients with IIH and venous sinus stenosis with an elevated pressure gradient and elevated ICP, venous sinus stenting results in resolution of the venous pressure gradient, reduction in ICP, and functional, neurological, and ophthalmological improvement. As patients are at risk for stent-adjacent stenosis, further follow-up is necessary to determine long-term outcomes and gain an understanding of venous sinus stenosis as a primary or secondary pathological process behind elevated ICP.
NASA Astrophysics Data System (ADS)
Poon, Eric; Thondapu, Vikas; Barlis, Peter; Ooi, Andrew
2017-11-01
Coronary artery disease remains a major cause of mortality in developed countries, and is most often due to a localized flow-limiting stenosis, or narrowing, of coronary arteries. Patients often undergo invasive procedures such as X-ray angiography and fractional flow reserve to diagnose flow-limiting lesions. Even though such diagnostic techniques are well-developed, the effects of diseased coronary segments on local flow are still poorly understood. Therefore, this study investigated the effect of irregular geometries of diseased coronary segments on the macro-recirculation and local pressure minimum regions. We employed an idealized coronary artery model with a diameter of stenosis of 75%. By systematically adjusting the eccentricity and the asymmetry of the coronary stenosis, we uncovered an increase in macro-recirculation size. Most importantly, the presence of this macro-recirculation signifies a local pressure minimum (identified by λ2 vortex identification method). This local pressure minimum has a profound effect on the pressure drops in both longitudinal and planar directions, which has implications for diagnosis and treatment of coronary artery disease. Supported by Australian Research Council LP150100233 and National Computational Infrastructure m45.
Carotid disease at age 73 and cognitive change from age 70 to 76 years: A longitudinal cohort study
Allerhand, Michael; Eadie, Elizabeth; Thomas, Avril; Corley, Janey; Pattie, Alison; Taylor, Adele; Shenkin, Susan D; Cox, Simon; Gow, Alan; Starr, John M; Deary, Ian J
2016-01-01
Cognitive decline and carotid artery atheroma are common at older ages. In community-dwelling subjects, we assessed cognition at ages 70, 73 and 76 and carotid Doppler ultrasound at age 73, to determine whether carotid stenosis was related to cognitive decline. We used latent growth curve models to examine associations between four carotid measures (internal carotid artery stenosis, velocity, pulsatility and resistivity indices) and four cognitive ability domains (memory, visuospatial function, crystallised intelligence, processing speed) adjusted for cognitive ability at age 11, current age, gender and vascular risk factors. Amongst 866 participants, carotid stenosis (median 12.96%) was not associated with cognitive abilities at age 70 or cognitive decline from age 70 to 76. Increased ICA pulsatility and resistivity indices were associated with slower processing speed (both P < 0.001) and worse visuospatial function (P = 0.036, 0.031, respectively) at age 70, and declining crystallised intelligence from ages 70 to 76 (P = 0.008, 0.006, respectively). The findings suggest that vascular stiffening, rather than carotid luminal narrowing, adversely influences cognitive ageing and provides a potential target for ameliorating age-related cognitive decline. PMID:28155579
Carotid disease at age 73 and cognitive change from age 70 to 76 years: A longitudinal cohort study.
Wardlaw, Joanna M; Allerhand, Michael; Eadie, Elizabeth; Thomas, Avril; Corley, Janey; Pattie, Alison; Taylor, Adele; Shenkin, Susan D; Cox, Simon; Gow, Alan; Starr, John M; Deary, Ian J
2017-08-01
Cognitive decline and carotid artery atheroma are common at older ages. In community-dwelling subjects, we assessed cognition at ages 70, 73 and 76 and carotid Doppler ultrasound at age 73, to determine whether carotid stenosis was related to cognitive decline. We used latent growth curve models to examine associations between four carotid measures (internal carotid artery stenosis, velocity, pulsatility and resistivity indices) and four cognitive ability domains (memory, visuospatial function, crystallised intelligence, processing speed) adjusted for cognitive ability at age 11, current age, gender and vascular risk factors. Amongst 866 participants, carotid stenosis (median 12.96%) was not associated with cognitive abilities at age 70 or cognitive decline from age 70 to 76. Increased ICA pulsatility and resistivity indices were associated with slower processing speed (both P < 0.001) and worse visuospatial function ( P = 0.036, 0.031, respectively) at age 70, and declining crystallised intelligence from ages 70 to 76 ( P = 0.008, 0.006, respectively). The findings suggest that vascular stiffening, rather than carotid luminal narrowing, adversely influences cognitive ageing and provides a potential target for ameliorating age-related cognitive decline.
Improved Strategies and Optimization of Calibration Models for Real-time PCR Absolute Quantification
Real-time PCR absolute quantification applications rely on the use of standard curves to make estimates of DNA target concentrations in unknown samples. Traditional absolute quantification approaches dictate that a standard curve must accompany each experimental run. However, t...
Wilson, Gregory J; McGregor, Jennifer; Conditt, Gerard; Shibuya, Masahiko; Sushkova, Natalia; Eppihimer, Michael J; Hawley, Steven P; Rouselle, Serge D; Huibregtse, Barbara A; Dawkins, Keith D; Granada, Juan F
2018-02-20
Drug-eluting stents (DES) have evolved to using bioresorbable polymers as a method of drug delivery. The impact of bioresorbable polymer on long-term neointimal formation, inflammation, and healing has not been fully characterised. This study aimed to evaluate the biological effect of polymer resorption on vascular healing and inflammation. A comparative DES study was performed in the familial hypercholesterolaemic swine model of coronary stenosis. Permanent polymer DES (zotarolimus-eluting [ZES] or everolimus-eluting [EES]) were compared to bioresorbable polymer everolimus-eluting stents (BP-EES) and BMS. Post implantation in 29 swine, stents were explanted and analysed up to 180 days. Area stenosis was reduced in all DES compared to BMS at 30 days. At 180 days, BP-EES had significantly lower area stenosis than EES or ZES. Severe inflammatory activity persisted in permanent polymer DES at 180 days compared to BP-EES or BMS. Qualitative para-strut inflammation areas (graded as none to severe) were elevated but similar in all groups at 30 days, peaked at 90 days in DES compared to BMS (p<0.05) and, at 180 days, were similar between BMS and BP-EES but were significantly greater in DES. BP-EES resulted in a lower net long-term reduction in neointimal formation and inflammation compared to permanent polymer DES in an animal model. Further study of the long-term neointima formation deserves study in human clinical trials.
Kobayashi, S; Uchida, K; Takeno, K; Baba, H; Suzuki, Y; Hayakawa, K; Yoshizawa, H
2006-02-01
It has been reported that disturbance of blood flow arising from circumferential compression of the cauda equina by surrounding tissue plays a major role in the appearance of neurogenic intermittent claudication (NIC) associated with lumbar spinal canal stenosis (LSCS). We created a model of LSCS to clarify the mechanism of enhancement within the cauda equina on gadolinium-enhanced MR images from patients with LSCS. In 20 dogs, a lumbar laminectomy was performed by applying circumferential constriction to the cauda equina by using a silicon tube, to produce 30% stenosis of the circumferential diameter of the dural tube. After 1 and 3 weeks, gadolinium and Evans blue albumin were injected intravenously at the same time. The sections were used to investigate the status of the blood-nerve barrier function under a fluorescence microscope and we compared gadolinium-enhanced MR images with Evans blue albumin distribution in the nerve. The other sections were used for light and transmission electron microscopic study. In this model, histologic examination showed congestion and dilation in many of the intraradicular veins, as well as inflammatory cell infiltration. The intraradicular edema caused by venous congestion and Wallerian degeneration can also occur at sites that are not subject to mechanical compression. Enhanced MR imaging showed enhancement of the cauda equina at the stenosed region, demonstrating the presence of edema. Gadolinium-enhanced MR imaging may be a useful tool for the diagnosis of microcirculatory disorders of the cauda equina associated with LSCS.
On the Confounding Effect of Temperature on Chemical Shift-Encoded Fat Quantification
Hernando, Diego; Sharma, Samir D.; Kramer, Harald; Reeder, Scott B.
2014-01-01
Purpose To characterize the confounding effect of temperature on chemical shift-encoded (CSE) fat quantification. Methods The proton resonance frequency of water, unlike triglycerides, depends on temperature. This leads to a temperature dependence of the spectral models of fat (relative to water) that are commonly used by CSE-MRI methods. Simulation analysis was performed for 1.5 Tesla CSE fat–water signals at various temperatures and echo time combinations. Oil–water phantoms were constructed and scanned at temperatures between 0 and 40°C using spectroscopy and CSE imaging at three echo time combinations. An explanted human liver, rejected for transplantation due to steatosis, was scanned using spectroscopy and CSE imaging. Fat–water reconstructions were performed using four different techniques: magnitude and complex fitting, with standard or temperature-corrected signal modeling. Results In all experiments, magnitude fitting with standard signal modeling resulted in large fat quantification errors. Errors were largest for echo time combinations near TEinit ≈ 1.3 ms, ΔTE ≈ 2.2 ms. Errors in fat quantification caused by temperature-related frequency shifts were smaller with complex fitting, and were avoided using a temperature-corrected signal model. Conclusion Temperature is a confounding factor for fat quantification. If not accounted for, it can result in large errors in fat quantifications in phantom and ex vivo acquisitions. PMID:24123362
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wehrschuetz, M., E-mail: martin.wehrschuetz@klinikum-graz.at; Aschauer, M.; Portugaller, H.
The purpose of this study was to assess interobserver variability and accuracy in the evaluation of renal artery stenosis (RAS) with gadolinium-enhanced MR angiography (MRA) and digital subtraction angiography (DSA) in patients with hypertension. The authors found that source images are more accurate than maximum intensity projection (MIP) for depicting renal artery stenosis. Two independent radiologists reviewed MRA and DSA from 38 patients with hypertension. Studies were postprocessed to display images in MIP and source images. DSA was the standard for comparison in each patient. For each main renal artery, percentage stenosis was estimated for any stenosis detected by themore » two radiologists. To calculate sensitivity, specificity and accuracy, MRA studies and stenoses were categorized as normal, mild (1-39%), moderate (40-69%) or severe ({>=}70%), or occluded. DSA stenosis estimates of 70% or greater were considered hemodynamically significant. Analysis of variance demonstrated that MIP estimates of stenosis were greater than source image estimates for both readers. Differences in estimates for MIP versus DSA reached significance in one reader. The interobserver variance for MIP, source images and DSA was excellent (0.80< {kappa}{<=} 0.90). The specificity of source images was high (97%) but less for MIP (87%); average accuracy was 92% for MIP and 98% for source images. In this study, source images are significantly more accurate than MIP images in one reader with a similar trend was observed in the second reader. The interobserver variability was excellent. When renal artery stenosis is a consideration, high accuracy can only be obtained when source images are examined.« less
Dahm, J B; Ruppert, J; Hartmann, S; Vogelgesang, D; Hummel, A; Felix, S B
2006-01-01
Objectives To examine by retrospective analysis of data from the FLEXI‐CUT monocentre registry whether atherectomy can effectively simplify complex stent implantation in ostial bifurcation lesions by reducing the procedure to stenting of the left anterior descending (LAD) or left circumflex (LCX) artery ostium alone. Patients and methods All patients who had been enrolled in the prospective FLEXI‐CUT study (directional atherectomy with adjunctive balloon angioplasty) were retrospectively analysed on the basis of significant LAD or LCX ostial stenosis (⩾ 70% stenosis) deriving from an undiseased left main stem. The primary combined end point was the rate of target lesion revascularisation (TLR) and binary restenosis; secondary end points were procedural success and major adverse cardiac events (MACE) at the six‐month follow up. Results Of 30 patients enrolled with significant LAD or LCX ostium stenosis, 29 were effectively treated with directional atherectomy (96.7% procedural success). All patients underwent single‐vessel stenting procedures of solely the LAD or LCX ostium. At follow up, binary stenosis was 25% (6 of 24), TLR (angiographic plus clinical) 10.3% (3 of 29) and total MACE 6.9% (2 of 29). Conclusions Directional atherectomy with single‐vessel stenting procedures facilitates the interventional treatment of LAD and LCX ostium stenosis, and leads to remarkably low TLR and binary stenosis at follow up. PMID:16449510
Ali, Abid; Ashrafi, Mohammed; Zeynali, Iraj
2015-01-01
Spontaneous resolution of carotid stenosis is a phenomenon that has been described in literature in the past. At present it is not routine practise to scan patients prior to carotid endarterectomy surgery within the UK. A 58 year old female presented to hospital with a history of sudden onset headache and left sided weakness. CT head showed findings in keeping with an acute right MCA territory infarct. A duplex ultrasound scan showed echolucent material in the right internal carotid artery forming a greater than 95% stenosis. The scan was unable to visualise the patency of the vessel distally due to the position of the mandible. The patient was provisionally listed for carotid endarterectomy. An MRA was requested prior to surgery to assess the patency of the distal internal carotid artery. The MRA of the carotids showed normal appearance of the common carotid, internal and vertebral arteries with no definite stenosis. A repeat duplex ultrasound confirmed there was no significant stenosis. The finding of complete resolution of stenosis on MRA was an unexpected event. Had the initial duplex imaging allowed visualisation of the distal vessel patency, our patient would have undergone unnecessary carotid surgery with the associated morbidity and mortality. This case report draws attention to the benefits of selective preoperative scanning, in sparing patients from unnecessary surgery as a result of finding occlusion or resolution of a previously diagnosed carotid stenosis. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sada, Sujay; Reddy, Yugandhar; Rao, Sampath; Alladi, Suvarna; Kaul, Subash
2014-01-01
Middle cerebral artery (MCA) disease is the most common vascular lesion in stroke. Transcranial Doppler (TCD) is a non-invasive bedside screening method for assessing cerebral blood flow. To investigate the prevalence of MCA stenosis in asymptomatic but high-risk individuals for stroke. Prospective study between December 2011 and December 2013. Vascular risk factors considered included: hypertension (HTN), diabetes mellitus, smoking, alcohol consumption, coronary artery disease (CAD), peripheral vascular disease (PVD), hypercholesterolemia and obesity. TCD was performed with portable machine through the temporal windows by use of a standardized protocol. Of the 427 subjects, 374 were analyzed; males 264 (70.6%) and females 110 (29.4%). Mean age was 54.2 ± 7.6 years. The frequency of the risk factors was: HTN 287 (76.7%), diabetes 220 (58.8%), CAD 120 (32.1%), hypercholesterolemia 181 (48.4%), smoking 147 (39.3%), alcohol 99 (26.5%), obesity 198 (52.9%) and PVD 8 (2.1%). Of the 374 subjects, 27 (7.2%) had intracranial arterial stenosis and the rest had normal intracranial arteries. On univariate analysis, subjects with higher age, HTN, CAD, smoking and hypercholesterolemia had higher risk of having intracranial arterial stenosis (P < 0.05). Multivariate analysis showed HTN and CAD are independent risk factors for intracranial arterial stenosis. Overall prevalence of intracranial arterial stenosis is 7.2% in high-risk population sample from Hyderabad in South India. HTN and CAD are independent risk factors for the development of intracranial arterial stenosis.
Pulmonary vein stenosis following catheter ablation of atrial fibrillation.
Pürerfellner, Helmut; Martinek, Martin
2005-11-01
This review provides an update on the mechanisms, incidence, and current management of significant pulmonary vein stenosis following catheter ablation of atrial fibrillation. Catheter ablation involving the pulmonary veins and the surrounding left atrial tissue is increasingly used to treat atrial fibrillation. In parallel with the fact that these procedures may cure a substantial proportion of patients, severe complications have been observed. Pulmonary vein stenosis is a new clinical entity produced by radiofrequency energy delivery mainly within or at the orifice of the pulmonary veins. The exact incidence is currently unknown because the diagnosis is dependent on the imaging modality and on the rigor with which patients are followed up. The optimal method for screening patients has not been determined. Stenosis of a pulmonary vein may be assessed by combining anatomic and functional imaging using computed tomographic or magnetic resonance imaging, transesophageal echocardiography, and lung scanning. Symptoms vary considerably and may be misdiagnosed, leading to severe clinical consequences. Current treatment strategies involve pulmonary vein dilatation or stenting; however, the restenosis rate remains high. The long-term outcome in patients with pulmonary vein stenosis is unclear. Strategies under development to prevent pulmonary vein stenosis include alternate energy sources and modified ablation techniques. Pulmonary vein stenosis following catheter ablation is a new clinical entity that has been described in various reports recently. There is much uncertainty with respect to causative factors, incidence, diagnosis, and treatment, and long-term sequelae are unclear.
Management of complex glottic stenosis in children with recurrent respiratory papillomatosis.
Siegel, Bianca; Smith, Lee P
2013-10-01
To describe our management of complex glottic stenosis in tracheotomy dependent children with severe recurrent respiratory papillomatosis. Retrospective chart review at a tertiary care children's hospital. Three children with complex glottic stenosis secondary to severe recurrent respiratory papillomatosis were treated at our institution since 2011. Two patients had complete stenosis, and the third had near-complete stenosis. Two patients were managed using balloon dilation alone, and the third also underwent laryngotracheal reconstruction with posterior costal cartilage grafting. Two patients have been successfully decannulated and the third has been tolerating continuous tracheotomy capping for greater than twelve months. All three patients underwent aggressive debridement of papillomatosis and balloon dilation every 4-6 weeks until their burden of disease was controlled. In two patients, the glottic airway was patent, and the third continued to have complete restenosis between procedures and required laryngotracheoplasty with multiple post-operative dilation procedures to establish an adequate glottic airway. Severe laryngeal stenosis is a well-described complication of recurrent respiratory papillomatosis, but its management is not well-defined. Aggressive management of papillomatosis with frequent debridement is critical in successfully managing laryngeal stenosis. Balloon dilation alone may be surprisingly effective in these patients, and laryngotracheoplasty can be used as an adjunct procedure in those patients who fail balloon dilation. Given the quality of life issues and concerns regarding distal spread of disease with tracheotomies in these patients, we feel that aggressive management and early decannulation is in the patient's best interest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Management of severe urethral complications of prostate cancer therapy.
Elliott, Sean P; McAninch, Jack W; Chi, Thomas; Doyle, Sean M; Master, Viraj A
2006-12-01
We present our management of urethral stenosis and rectourinary fistula resulting from prostate cancer therapy. We concentrated on cases refractory to minimally invasive treatment, such as dilation, urethrotomy, and urinary and/or fecal diversion. In our prospectively collected urethral reconstruction database we identified patients who underwent reconstruction of urethral stenosis or rectourinary fistula who also received prior treatment for prostate cancer. We documented demographics, prostate cancer pretreatment characteristics, prostate cancer therapy type, urethral reconstruction type and success. A total of 48 patients met the inclusion criteria, including 16 with rectourinary fistula and 32 with urethral stenosis. Urethral complications followed prior radical prostatectomy, brachytherapy, external beam radiotherapy, cryotherapy, thermal ablation and any combination of these procedures. Stenosis repair was successful in 23 of 32 cases (73%) and it differed little between anterior and posterior urethral stenosis. Repair was accomplished by anastomotic urethroplasty in 19 cases, flap urethroplasty in 2, perineal urethrostomy in 2 and a urethral stent in 9. Prior external beam radiotherapy was a risk factor for urethral reconstruction failure. Fistula repair was successful in 14 of 15 patients (93%), excluding 1 who died postoperatively. The complexity of fistula management was dictated by fistula size and the presence or absence of coincident urethral stenosis. Urethral stenosis or rectourethral fistula following prostate cancer therapy can be managed by urethral reconstruction, such that normal voiding via the urethra is maintained, rather than abandoning the urethral outlet and performing heterotopic diversion. This can be accomplished with an acceptable rate of failure, given the complexity of the cases.
Miyase, Yuiko; Miura, Shin-Ichiro; Shiga, Yuhei; Yano, Masaya; Suematsu, Yasunori; Adachi, Sen; Norimatsu, Kenji; Nakamura, Ayumi; Saku, Keijiro
2016-01-01
A difference in systolic blood pressure (SBP) ≥10 mmHg between the arms is associated with an increased risk of coronary artery disease (CAD) and mortality in high-risk patients. Four hundred and fourteen patients were divided into three groups according to the percent most severe luminal narrowing of a coronary artery as diagnosed by coronary computed tomography angiography: no or mild coronary stenosis (0-49%), moderate stenosis (50-69%) and severe stenosis (≥70%) groups. The relative difference in SBP between arms in the severe group was significantly lower than those in the no or mild and moderate groups. The brachial-ankle pulse wave velocity (baPWV) significantly increased as the severity of coronary stenosis increased. We confirmed that severe coronary stenosis was independently associated with both the relative difference in SBP between arms and baPWV, in addition to age, gender, hypertension, dyslipidemia, diabetes mellitus and ankle-brachial index by a logistic regression analysis. The group with a relative difference in SBP between arms of <1 mmHg and baPWV ≥ 1613 cm/s showed a higher percentage of patients with severe coronary stenosis than groups that met neither or only one of these criteria. The combination of the relative difference in SBP between arms and baPWV may be a more effective approach for the non-invasive assessment of the severity of CAD.
Henderson, A L; Hecht, S; Millis, D L
2015-10-01
To investigate whether dogs with degenerative lumbosacral stenosis have decreased lumbar paraspinal muscle transverse area and symmetry compared with control dogs. Retrospective cross-sectional study comparing muscles in transverse T2-weighted magnetic resonance images for nine dogs with and nine dogs without degenerative -lumbosacral stenosis. Mean transverse area was measured for the lumbar multifidus and sacrocaudalis dorsalis lateralis muscles bilaterally and the L7 vertebral body at the level of the caudal endplate. Transverse areas of both muscle groups relative to L7 and asymmetry indices were compared between study populations using independent t tests. Mean muscle-to-L7 transverse area ratios were significantly smaller in the degenerative lumbosacral stenosis group compared with those in the control group in both lumbar multifidus (0·84 ±0·26 versus 1·09 ±0·25; P=0·027) and sacrocaudalis dorsalis lateralis (0·5 ±0·15 versus 0·68 ±0·12; P=0·005) muscles. Mean asymmetry indices were higher for both muscles in the group with degenerative lumbosacral stenosis than in the control group, but highly variable and the difference was not statistically significant. These findings suggest that dogs with degenerative lumbosacral stenosis have decreased lumbar paraspinal muscle mass that may be a cause or consequence of the -syndrome. Understanding altered paraspinal muscle characteristics may improve understanding of the -pathophysiology and management options for degenerative lumbosacral stenosis. © 2015 British Small Animal Veterinary Association.
Kumagai, Hozumi; Nio, Kenta; Shirakawa, Tsuyoshi; Uchino, Keita; Kusaba, Hitoshi; Isobe, Taichi; Komoda, Masato; Tamura, Shingo; Maeyama, Ryo; Nagai, Eishi; Akashi, Koichi; Baba, Eishi
2012-09-19
Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient's general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.
Management of carotid stenosis in women
Brown, Martin M.; Didier, Leys; Howard, Virginia J.; Moore, Wesley S.; Paciaroni, Maurizio; Ringleb, Peter; Rockman, Caron; Caso, Valeria
2013-01-01
Objective: Specific guidelines for management of cerebrovascular risk in women are currently lacking. This study aims to provide a consensus expert opinion to help make clinical decisions in women with carotid stenosis. Methods: Proposals for the use of carotid endarterectomy (CEA), carotid stenting (CAS), and medical therapy for stroke prevention in women with carotid stenosis were provided by a group of 9 international experts with consensus method. Results: Symptomatic women with severe carotid stenosis can be managed by CEA provided that the perioperative risk of the operators is low (<4%). Periprocedural stroke risks may be increased in symptomatic women if revascularization is performed by CAS; however, the choice of CAS vs CEA can be tailored in subgroups best fit for each procedure (e.g., women with restenosis or severe coronary disease, best suited for CAS; women with tortuous vessels or old age, best suited for CEA). There is currently limited evidence to consider medical therapy alone as the best choice for women with neurologically severe asymptomatic carotid stenosis, who should be best managed within randomized trials including a medical arm. Medical management and cardiovascular risk factor control must be implemented in all women with carotid stenosis in periprocedural period and lifelong regardless of whether or not intervention is planned. Conclusions: The suggestions provided in this article may constitute a decision-making basis for planning treatment of carotid stenosis in women. Most recommendations are of limited strength; however, it is unlikely that new robust data will emerge soon to induce relevant changes. PMID:23751919
Fluid-structure interaction analysis of the flow through a stenotic aortic valve
NASA Astrophysics Data System (ADS)
Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes
2009-11-01
In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.
Smith, J. Gustav; Luk, Kevin; Schulz, Christina-Alexandra; Engert, James C.; Do, Ron; Hindy, George; Rukh, Gull; Dufresne, Line; Almgren, Peter; Owens, David S.; Harris, Tamara B.; Peloso, Gina M.; Kerr, Kathleen F.; Wong, Quenna; Smith, Albert V.; Budoff, Matthew J.; Rotter, Jerome I.; Cupples, L. Adrienne; Rich, Stephen; Kathiresan, Sekar; Orho-Melander, Marju; Gudnason, Vilmundur; O’Donnell, Christopher J.; Post, Wendy S.; Thanassoulis, George
2014-01-01
IMPORTANCE Plasma low-density lipoprotein cholesterol (LDL-C) has been associated with aortic stenosis in observational studies; however, randomized trials with cholesterol-lowering therapies in individuals with established valve disease have failed to demonstrate reduced disease progression. OBJECTIVE To evaluate whether genetic data are consistent with an association between LDL-C, high-density lipoprotein cholesterol (HDL-C), or triglycerides (TG) and aortic valve disease. DESIGN, SETTING, AND PARTICIPANTS Using a Mendelian randomization study design, we evaluated whether weighted genetic risk scores (GRSs), a measure of the genetic predisposition to elevations in plasma lipids, constructed using single-nucleotide polymorphisms identified in genome-wide association studies for plasma lipids, were associated with aortic valve disease. We included community-based cohorts participating in the CHARGE consortium (n = 6942), including the Framingham Heart Study (cohort inception to last follow-up: 1971-2013; n = 1295), Multi-Ethnic Study of Atherosclerosis (2000-2012; n = 2527), Age Gene/Environment Study-Reykjavik (2000-2012; n = 3120), and the Malmö Diet and Cancer Study (MDCS, 1991-2010; n = 28 461). MAIN OUTCOMES AND MEASURES Aortic valve calcium quantified by computed tomography in CHARGE and incident aortic stenosis in the MDCS. RESULTS The prevalence of aortic valve calcium across the 3 CHARGE cohorts was 32% (n = 2245). In the MDCS, over a median follow-up time of 16.1 years, aortic stenosis developed in 17 per 1000 participants (n = 473) and aortic valve replacement for aortic stenosis occurred in 7 per 1000 (n = 205). Plasma LDL-C, but not HDL-C or TG, was significantly associated with incident aortic stenosis (hazard ratio [HR] per mmol/L, 1.28; 95% CI, 1.04-1.57; P = .02; aortic stenosis incidence: 1.3% and 2.4% in lowest and highest LDL-C quartiles, respectively). The LDL-C GRS, but not HDL-C or TG GRS, was significantly associated with presence of aortic valve calcium in CHARGE (odds ratio [OR] per GRS increment, 1.38; 95% CI, 1.09-1.74; P = .007) and with incident aortic stenosis in MDCS (HR per GRS increment, 2.78; 95% CI, 1.22-6.37; P = .02; aortic stenosis incidence: 1.9% and 2.6% in lowest and highest GRS quartiles, respectively). In sensitivity analyses excluding variants weakly associated with HDL-C or TG, the LDL-C GRS remained associated with aortic valve calcium (P = .03) and aortic stenosis (P = .009). In instrumental variable analysis, LDL-C was associated with an increase in the risk of incident aortic stenosis (HR per mmol/L, 1.51; 95% CI, 1.07-2.14; P = .02). CONCLUSIONS AND RELEVANCE Genetic predisposition to elevated LDL-C was associated with presence of aortic valve calcium and incidence of aortic stenosis, providing evidence supportive of a causal association between LDL-C and aortic valve disease. Whether earlier intervention to reduce LDL-C could prevent aortic valve disease merits further investigation. PMID:25344734
How to Make Data a Blessing to Parametric Uncertainty Quantification and Reduction?
NASA Astrophysics Data System (ADS)
Ye, M.; Shi, X.; Curtis, G. P.; Kohler, M.; Wu, J.
2013-12-01
In a Bayesian point of view, probability of model parameters and predictions are conditioned on data used for parameter inference and prediction analysis. It is critical to use appropriate data for quantifying parametric uncertainty and its propagation to model predictions. However, data are always limited and imperfect. When a dataset cannot properly constrain model parameters, it may lead to inaccurate uncertainty quantification. While in this case data appears to be a curse to uncertainty quantification, a comprehensive modeling analysis may help understand the cause and characteristics of parametric uncertainty and thus turns data into a blessing. In this study, we illustrate impacts of data on uncertainty quantification and reduction using an example of surface complexation model (SCM) developed to simulate uranyl (U(VI)) adsorption. The model includes two adsorption sites, referred to as strong and weak sites. The amount of uranium adsorption on these sites determines both the mean arrival time and the long tail of the breakthrough curves. There is one reaction on the weak site but two reactions on the strong site. The unknown parameters include fractions of the total surface site density of the two sites and surface complex formation constants of the three reactions. A total of seven experiments were conducted with different geochemical conditions to estimate these parameters. The experiments with low initial concentration of U(VI) result in a large amount of parametric uncertainty. A modeling analysis shows that it is because the experiments cannot distinguish the relative adsorption affinity of the strong and weak sites on uranium adsorption. Therefore, the experiments with high initial concentration of U(VI) are needed, because in the experiments the strong site is nearly saturated and the weak site can be determined. The experiments with high initial concentration of U(VI) are a blessing to uncertainty quantification, and the experiments with low initial concentration help modelers turn a curse into a blessing. The data impacts on uncertainty quantification and reduction are quantified using probability density functions of model parameters obtained from Markov Chain Monte Carlo simulation using the DREAM algorithm. This study provides insights to model calibration, uncertainty quantification, experiment design, and data collection in groundwater reactive transport modeling and other environmental modeling.
Urbina, Angel; Mahadevan, Sankaran; Paez, Thomas L.
2012-03-01
Here, performance assessment of complex systems is ideally accomplished through system-level testing, but because they are expensive, such tests are seldom performed. On the other hand, for economic reasons, data from tests on individual components that are parts of complex systems are more readily available. The lack of system-level data leads to a need to build computational models of systems and use them for performance prediction in lieu of experiments. Because their complexity, models are sometimes built in a hierarchical manner, starting with simple components, progressing to collections of components, and finally, to the full system. Quantification of uncertainty inmore » the predicted response of a system model is required in order to establish confidence in the representation of actual system behavior. This paper proposes a framework for the complex, but very practical problem of quantification of uncertainty in system-level model predictions. It is based on Bayes networks and uses the available data at multiple levels of complexity (i.e., components, subsystem, etc.). Because epistemic sources of uncertainty were shown to be secondary, in this application, aleatoric only uncertainty is included in the present uncertainty quantification. An example showing application of the techniques to uncertainty quantification of measures of response of a real, complex aerospace system is included.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huan, Xun; Safta, Cosmin; Sargsyan, Khachik
The development of scramjet engines is an important research area for advancing hypersonic and orbital flights. Progress toward optimal engine designs requires accurate flow simulations together with uncertainty quantification. However, performing uncertainty quantification for scramjet simulations is challenging due to the large number of uncertain parameters involved and the high computational cost of flow simulations. These difficulties are addressed in this paper by developing practical uncertainty quantification algorithms and computational methods, and deploying them in the current study to large-eddy simulations of a jet in crossflow inside a simplified HIFiRE Direct Connect Rig scramjet combustor. First, global sensitivity analysis ismore » conducted to identify influential uncertain input parameters, which can help reduce the system’s stochastic dimension. Second, because models of different fidelity are used in the overall uncertainty quantification assessment, a framework for quantifying and propagating the uncertainty due to model error is presented. In conclusion, these methods are demonstrated on a nonreacting jet-in-crossflow test problem in a simplified scramjet geometry, with parameter space up to 24 dimensions, using static and dynamic treatments of the turbulence subgrid model, and with two-dimensional and three-dimensional geometries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huan, Xun; Safta, Cosmin; Sargsyan, Khachik
The development of scramjet engines is an important research area for advancing hypersonic and orbital flights. Progress toward optimal engine designs requires accurate flow simulations together with uncertainty quantification. However, performing uncertainty quantification for scramjet simulations is challenging due to the large number of uncertain parameters involved and the high computational cost of flow simulations. These difficulties are addressed in this paper by developing practical uncertainty quantification algorithms and computational methods, and deploying them in the current study to large-eddy simulations of a jet in crossflow inside a simplified HIFiRE Direct Connect Rig scramjet combustor. First, global sensitivity analysis ismore » conducted to identify influential uncertain input parameters, which can help reduce the system’s stochastic dimension. Second, because models of different fidelity are used in the overall uncertainty quantification assessment, a framework for quantifying and propagating the uncertainty due to model error is presented. Finally, these methods are demonstrated on a nonreacting jet-in-crossflow test problem in a simplified scramjet geometry, with parameter space up to 24 dimensions, using static and dynamic treatments of the turbulence subgrid model, and with two-dimensional and three-dimensional geometries.« less
NASA Astrophysics Data System (ADS)
Huan, Xun; Safta, Cosmin; Sargsyan, Khachik; Geraci, Gianluca; Eldred, Michael S.; Vane, Zachary P.; Lacaze, Guilhem; Oefelein, Joseph C.; Najm, Habib N.
2018-03-01
The development of scramjet engines is an important research area for advancing hypersonic and orbital flights. Progress toward optimal engine designs requires accurate flow simulations together with uncertainty quantification. However, performing uncertainty quantification for scramjet simulations is challenging due to the large number of uncertain parameters involved and the high computational cost of flow simulations. These difficulties are addressed in this paper by developing practical uncertainty quantification algorithms and computational methods, and deploying them in the current study to large-eddy simulations of a jet in crossflow inside a simplified HIFiRE Direct Connect Rig scramjet combustor. First, global sensitivity analysis is conducted to identify influential uncertain input parameters, which can help reduce the systems stochastic dimension. Second, because models of different fidelity are used in the overall uncertainty quantification assessment, a framework for quantifying and propagating the uncertainty due to model error is presented. These methods are demonstrated on a nonreacting jet-in-crossflow test problem in a simplified scramjet geometry, with parameter space up to 24 dimensions, using static and dynamic treatments of the turbulence subgrid model, and with two-dimensional and three-dimensional geometries.
Huan, Xun; Safta, Cosmin; Sargsyan, Khachik; ...
2018-02-09
The development of scramjet engines is an important research area for advancing hypersonic and orbital flights. Progress toward optimal engine designs requires accurate flow simulations together with uncertainty quantification. However, performing uncertainty quantification for scramjet simulations is challenging due to the large number of uncertain parameters involved and the high computational cost of flow simulations. These difficulties are addressed in this paper by developing practical uncertainty quantification algorithms and computational methods, and deploying them in the current study to large-eddy simulations of a jet in crossflow inside a simplified HIFiRE Direct Connect Rig scramjet combustor. First, global sensitivity analysis ismore » conducted to identify influential uncertain input parameters, which can help reduce the system’s stochastic dimension. Second, because models of different fidelity are used in the overall uncertainty quantification assessment, a framework for quantifying and propagating the uncertainty due to model error is presented. In conclusion, these methods are demonstrated on a nonreacting jet-in-crossflow test problem in a simplified scramjet geometry, with parameter space up to 24 dimensions, using static and dynamic treatments of the turbulence subgrid model, and with two-dimensional and three-dimensional geometries.« less
2006-08-01
severe aortic stenosis . Figure 1F. Oblique axial cine bright blood imaging through the valve plane of the aorta, demonstrates the aortic valve to...the ascending aorta. This moderate to large jet is consistent with moderate to severe aortic stenosis . No diastolic jet to suggest aortic ...conditions. Functional impairment of the aortic valve—namely aortic stenosis and aortic regurgitation—is the most common complication (in up to 68-85% of
Unusual Giant Right Atrium in Rheumatic Mitral Stenosis and Tricuspid Insufficiency
Anzouan-Kacou, Jean Baptiste; Konin, Christophe; Coulibaly, Iklo; N'guetta, Roland; Adoubi, Anicet; Soya, Esaïe; Boka, Bénédicte
2011-01-01
Dilation and hypertrophy of the atria occur in patients with valvular heart disease especially in mitral regurgitation, mitral stenosis or tricuspid abnormalities. In sub-saharan Africa, rheumatic fever is still the leading cause of valvular heart disease. We report a case of an unusual giant right atrium in context of rheumatic stenosis and severe tricuspid regurgitation in a 58-year-old woman. PMID:24826228
The Application of Liquid Nitrogen Spray Cryotherapy in Treatment of Bronchial Stenosis.
Janke, Kelly J; Abbas, Abbas El-Sayed; Ambur, Vishnu; Yu, Daohai
Spray cryotherapy (SCT), the application of liquid nitrogen in a noncontact form, has been demonstrated to have efficacy in treating various types of pathologic lesions of the airway when used as an adjunct with bronchoscopy. The purpose of the study was to evaluate the results of the use of bronchoscopic SCT on the airway in a single institution. We performed a retrospective review of data collected on all patients who underwent SCT to re-establish or improve airway patency in an 11-month period. Patients were classified based on the nature of their disease into benign or malignant. Demographic data, change in luminal patency, and clinical outcomes were recorded. The percent of stenosis was divided into grades according to the following classification: 1, ≤25%; 2, 26% to 50%; 3, 51% to 75%; and 4, ≥76%. We defined successful completion of treatment as obtaining a final patency of grade 1. Twenty-two patients met inclusion criteria, with 45.5% (10 patients) having benign stenosis and 54.5% (12 patients) malignant. At initial bronchoscopic evaluation, the median grade of stenosis was 4 for malignant disease and 3.5 for benign disease. The median final posttreatment grade of stenosis was 2 for malignant disease and 1 for benign. The median improvement in grade of stenosis after treatment was 2 for both malignant and benign causes (Wilcoxon test, P = 0.92). Final patency of grade 1 was achieved in 42% of malignant stenosis and 80% of benign. Overall, 86.4% of patients had an improvement in grade of stenosis after treatment. The rate of morbidity was 4.5% (1/22) of all patients. The median change in grade after treatment was 2 grades of improvement for both the benign and malignant groups. These results provide evidence that the use of SCT is equally efficacious for both types of stenosis with an expectation of overall improvement in luminal patency, offering a safe and effective method of achieving airway patency in a minimally invasive fashion. This study contributes to the small but growing body of literature supporting the use of SCT in benign and malignant disease.
Relationship between exercise pressure gradient and haemodynamic progression of aortic stenosis.
Ringle, Anne; Levy, Franck; Ennezat, Pierre-Vladimir; Le Goffic, Caroline; Castel, Anne-Laure; Delelis, François; Menet, Aymeric; Malaquin, Dorothée; Graux, Pierre; Vincentelli, André; Tribouilloy, Christophe; Maréchaux, Sylvestre
We hypothesized that large exercise-induced increases in aortic mean pressure gradient can predict haemodynamic progression during follow-up in asymptomatic patients with aortic stenosis. We retrospectively identified patients with asymptomatic moderate or severe aortic stenosis (aortic valve area<1.5cm 2 or<1cm 2 ) and normal ejection fraction, who underwent an exercise stress echocardiography at baseline with a normal exercise test and a resting echocardiography during follow-up. The relationship between exercise-induced increase in aortic mean pressure gradient and annualised changes in resting mean pressure gradient during follow-up was investigated. Fifty-five patients (mean age 66±15 years; 45% severe aortic stenosis) were included. Aortic mean pressure gradient significantly increased from rest to peak exercise (P<0.001). During a median follow-up of 1.6 [1.1-3.2] years, resting mean pressure gradient increased from 35±13mmHg to 48±16mmHg, P<0.0001. Median annualised change in resting mean pressure gradient during follow-up was 5 [2-11] mmHg. Exercise-induced increase in aortic mean pressure gradient did correlate with annualised changes in mean pressure gradient during follow-up (r=0.35, P=0.01). Hemodynamic progression of aortic stenosis was faster in patients with large exercise-induced increase in aortic mean pressure gradient (≥20mmHg) as compared to those with exercise-induced increase in aortic mean pressure gradient<20mmHg (median annualised increase in mean pressure gradient 19 [6-28] vs. 4 [2-10] mmHg/y respectively, P=0.002). Similar results were found in the subgroup of 30 patients with moderate aortic stenosis. Large exercise-induced increases in aortic mean pressure gradient correlate with haemodynamic progression of stenosis during follow-up in patients with asymptomatic aortic stenosis. Further studies are needed to fully establish the role of ESE in the decision-making process in comparison to other prognostic markers in asymptomatic patients with aortic stenosis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Lu, Shan-Shan; Ge, Song; Su, Chun-Qiu; Xie, Jun; Mao, Jian; Shi, Hai-Bin; Hong, Xun-Ning
2017-10-30
Intracranial plaque characteristics are associated with stroke events. Differences in plaque features may explain the disconnect between stenosis severity and the presence of ischemic stroke. To investigate the relationship between plaque characteristics and downstream perfusion changes, and their contribution to the occurrence of cerebral infarction beyond luminal stenosis. Case control. Forty-six patients with symptomatic middle cerebral artery (MCA) stenosis (with acute cerebral infarction, n = 30; without acute cerebral infarction, n = 16). 3.0T with 3D turbo spin echo sequence (3D-SPACE). Luminal stenosis grade, plaque features including lesion T 2 and T 1 hyperintense components, plaque enhancement grade, and plaque distribution were assessed. Brain perfusion was evaluated on mean transient time maps based on the Alberta Stroke Program Early CT score (MTT-ASPECTS). Plaque features, grade of luminal stenosis, and MTT-ASPECTS were compared between two groups. The association between plaque features and MTT-ASPECTS were assessed using Spearman's correlation analysis. Multivariate logistic regression and receiver operating characteristic (ROC) curves were constructed to assess the effect of significant variables alone and their combination in determining the occurrence of cerebral infarction. Stronger enhanced plaques were associated with downstream lower MTT-ASPECTS (P = 0.010). Plaque enhancement grade (P = 0.039, odds ratio [OR] 5.9, 95% confidence interval [CI] 1.1-32) and MTT-ASPECTS (P = 0.003, OR 2.6, 95% CI 1.4-4.7) were associated with a recent cerebral infarction, whereas luminal stenosis grade was not (P = 0.128). The combination of MTT-ASPECTS and plaque enhancement grade provided incremental information beyond luminal stenosis grade alone. The area under the receiver operating characteristic curve (AUC) improved from 0.535 to 0.921 (P < 0.05). Strongly enhanced plaques are associated with a higher likelihood of downstream perfusion impairment. Plaque enhancement and perfusion evaluation may play a complementary role to luminal stenosis in determining the occurrence of acute cerebral infarction. 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Surgical Treatment of Anal Stenosis with Diamond Flap Anoplasty Performed in a Calibrated Fashion.
Gülen, Merter; Leventoğlu, Sezai; Ege, Bahadir; Menteş, B Bülent
2016-03-01
Regarding anoplasty for anal stenosis, it is not clear to what extent the final anal caliber should be targeted. The aim of this study was to investigate the results of diamond-flap anoplasty performed in a calibrated manner for the treatment of severe anal stenosis due to a previous hemorrhoidectomy. Prospectively prepared standard forms were evaluated retrospectively. Anoplasty with unilateral or bilateral diamond flaps was performed for moderate or severe anal stenosis, targeting a final anal caliber of 25 to 26 mm. The demographic characteristics, causes of anal stenosis, number of previous surgeries, anal stenosis staging (Milsom and Mazier), anal calibers (millimeter), the Cleveland Clinic Incontinence Score, and the modified obstructed defecation syndrome Longo score were recorded on pre-prepared standard forms, as well as postoperative complications and the time of return to work. From January 2011 to July 2013, 18 patients (12 males, 67%) with a median age of 39 years (range, 27-70) were treated. All of the patients had a history of previous hemorrhoidectomy. The number of previous corrective interventions was 2.1 ± 1.8 (range, 0-4), and 2 patients had a history of failed anoplasty. Five patients (28%) had moderate anal stenosis and 13 (72%) had severe anal stenosis. Preoperative, intraoperative, and 12-month postoperative anal calibration values were 9 ± 3 mm (range, 5-15), 25 ± 0.75 mm (range, 24-26), and 25 ± 1 mm (range, 23-27) (p < 0.0001, for immediate postoperative and 12-month postoperative anal calibers compared with the intraoperative). Preoperative and 12-month postoperative Cleveland Clinic Incontinence Scores were 0.83 ± 1.15 (range, 0-4) and 0.39 ± 0.70 (range, 0-2) (p = 1.0). The clinical success rate was 88.9%. No severe postoperative complications were observed. This study was limited because it was a single-armed, retrospective analysis of prospectively designed data. Diamond-flap anoplasty performed in a standardized and calibrated manner is a highly successful method for the treatment of anal stenosis caused by previous hemorrhoidectomy.
USDA-ARS?s Scientific Manuscript database
Satellite remote sensing provides continuous temporal and spatial information of terrestrial ecosystems. Using these remote sensing data and eddy flux measurements and biogeochemical models, such as the Terrestrial Ecosystem Model (TEM), should provide a more adequate quantification of carbon dynami...
4D optical coherence tomography of aortic valve dynamics in a murine mouse model ex vivo
NASA Astrophysics Data System (ADS)
Schnabel, Christian; Jannasch, Anett; Faak, Saskia; Waldow, Thomas; Koch, Edmund
2015-07-01
The heart and its mechanical components, especially the heart valves and leaflets, are under enormous strain during lifetime. Like all highly stressed materials, also these biological components undergo fatigue and signs of wear, which impinge upon cardiac output and in the end on health and living comfort of affected patients. Thereby pathophysiological changes of the aortic valve leading to calcific aortic valve stenosis (AVS) as most frequent heart valve disease in humans are of particular interest. The knowledge about changes of the dynamic behavior during the course of this disease and the possibility of early stage diagnosis could lead to the development of new treatment strategies and drug-based options of prevention or therapy. ApoE-/- mice as established model of AVS versus wildtype mice were introduced in an ex vivo artificially stimulated heart model. 4D optical coherence tomography (OCT) in combination with high-speed video microscopy were applied to characterize dynamic behavior of the murine aortic valve and to characterize dynamic properties during artificial stimulation. OCT and high-speed video microscopy with high spatial and temporal resolution represent promising tools for the investigation of dynamic behavior and their changes in calcific aortic stenosis disease models in mice.
Nair, Satish; Mohan, Sharad; Mandal, Ghanashyam; Nilakantan, Ajith
2014-01-01
Tracheal stenosis (TS), a challenging problem, is a known complication of prolonged intubation and tracheostomy. The management involves a multidisciplinary approach with multiple complex procedures. In this study we discuss our experience with severe TS with regards to patient characteristics, cause and management. A retrospective analysis of 20 patients of severe TS treated at a tertiary care centre was evaluated. Inclusion criteria were all patients with severe TS who required surgical intervention. Exclusion criteria were patients with associated laryngeal stenosis and TS due to cancer. Demographic data was recorded and findings relating to aetiology, characteristics of stenosis and the various aspects of therapeutic procedures performed are discussed with review of literature. Descriptive analysis of data were performed SPSS 18. Results of the 20 patients, 17 patients (85 %) developed TS post tracheostomy, or post intubation and subsequent tracheostomy. 13 Patients (65 %) had true stenosis of which 7 patients (35 %) had simple web or circumferential fibrosis and 6 patients (30 %) had complex stenosis. Seven patients (35 %) had granulations causing severe TS which were mostly suprastomal (5 patients), stomal (5 patients) and combined stomal and suprastomal (3 patients). The average length of stenosis was 3.57 cm (0.5-8 cm). Montgomery t tube insertion was a common procedure in 18 patients (90 %) pre or post intervention. Each patient underwent an average of 3.4 procedures during their course of treatment which included rigid bronchoscopy and mechanical debulking, Nd YAG laser, KTP laser, balloon dilatation and use of stents. Among the 7 patients with granulations 100 % successful decanulation was noted with endoscopic management whereas in 13 patients with true stenosis, 10 patients (76.9 %) required open surgical management (8 tracheal resection and anastomosis and 2 tracheoplasty) with 80 % successful decanulation, 2 patients (15.4 %) were treated with endoscopy with 100 % successful decanulation and 1 patient (7.7 %) was a non surgical candidate on stent. Of the total 20 patients with severe TS in this series, 17 (85 %) of patients who were decanulated, asymptomatic on routine daily activities with normal FFB were considered cured. TS is a challenging condition requiring a highly skilled multidisciplinary team for adequate management. Prolonged intubation and tracheostomy are the common causes leading to tracheal stenosis. Simple tracheal stenosis is easier to manage than a complex stenosis which usually requires an open surgical procedure for successful management. Presence of conditions like tracheoesophageal fistula and long segment tracheomalacia are poor factors for successful management. In our cases successful decanulation was possible in 85 % of the patients following a systematic multidisciplinary approach.
Numerical and experimental analysis of the transitional flow across a real stenosis.
Agujetas, R; Ferrera, C; Marcos, A C; Alejo, J P; Montanero, J M
2017-08-01
In this paper, we present a numerical study of the pulsatile transitional flow crossing a severe real stenosis located right in front of the bifurcation between the right subclavian and right common carotid arteries. The simulation allows one to determine relevant features of this subject-specific flow, such as the pressure waves in the right subclavian and right common carotid arteries. We explain the subclavian steal syndrome suffered by the patient in terms of the drastic pressure drop in the right subclavian artery. This pressure drop is caused by both the diverging part of the analyzed stenosis and the reverse flow in the bifurcation induced by another stenosis in the right internal carotid artery.
Rare Combination of Pathologies Causing Mitral Stenosis and Mitral Regurgitation: A Case Report.
Nair, Anupama K; Chowdhuri, Kuntal Roy; Radhakrishnan, Sitaraman; Iyer, Krishna S; Saxena, Manish
2018-01-01
A supramitral ring is a rare cause of mitral stenosis, while an isolated mitral valve cleft is a rare cause of congenital mitral regurgitation. Fortunately, both the lesions are known to have good outcomes after surgical correction. Although each is known to be associated with a variety of other structural heart defects, their coexistence has not been reported previously. We report a case of a three- and half-year-old boy detected to have a rare combination of supramitral ring producing severe mitral stenosis with a coexisting cleft in the anterior leaflet of mitral valve causing severe mitral regurgitation. The patient underwent successful surgical repair with resolution of both mitral stenosis and regurgitation.
Inoue Balloon Mitral Valvotomy in a 4-Year-Old Boy
Kapoor, Aditya; Moorthy, Nagaraja; Kumar, Sudeep
2012-01-01
Mitral stenosis in children often has a fulminant and rapid course. Percutaneous transvenous mitral commissurotomy is accepted as the treatment of choice for mitral stenosis not only in adults, but also in younger patients who have pliable valves. Balloon mitral valvotomy has yielded good immediate and long-term results. Herein, we report successful Inoue balloon mitral valvotomy in a 4-year-old boy who had severe, symptomatic rheumatic mitral stenosis. To our knowledge, our patient is the youngest to have undergone this procedure. In addition to the case description, we discuss the features of juvenile rheumatic mitral stenosis and several technical aspects of performing the Inoue balloon mitral valvotomy procedure in children. PMID:22412242
Intestinal Stenosis of Garré: An Old Problem Revisited
Marrelli, Daniele; Voglino, Costantino; Di Mare, Giulio; Ferrara, Francesco; Guazzi, Gianni; Croce, Federica; Costantini, Maurizio; Piagnerelli, Riccardo; Roviello, Franco
2015-01-01
Background Intestinal stenosis of Garré, first described in 1892, is a rare condition as a consequence of a complicated strangulated hernia. Preoperative diagnosis is challenging because of unspecific symptoms. Proper anamnesis, especially in terms of clinical and surgical history, as well as careful examination of both inguinal spaces is essential. Case Report We herein present a case of intestinal stenosis of Garré in a 70-year-old female. Conclusion Intestinal stenosis of Garré should be considered in cases of occlusive symptoms occurring after a non-operative or surgical reduction of a strangulated hernia. A correct diagnosis and an adequate surgical treatment are necessary to solve this rare complication favorably. PMID:26468318
Delayed relapse in pseudotumor cerebri due to new stenosis after transverse sinus stenting
Winters, Hugh Stephen; Parker, Geoff; Halmagyi, Gabor Michael; Mehta, Ankur; Atkins, Thomas
2015-01-01
A patient presented with recurrent severe pseudotumor cerebri (PTC). Transverse sinus stenting is a very effective treatment option, however stenosis and intracranial hypertension can recur. In our patient, stenting initially resulted in resolution of papilloedema. However, after 5 years, a new stenosis developed which required further stenting. This case highlights the fact that, in patients with PTC who undergo transverse sinus stenting, a small proportion require repeat treatment due to formation of a new stenosis, usually adjacent to the existing stent. Patients with severe disease, such as ours, may be at higher risk of recurrence. Regardless of the severity, all patients who undergo stenting should have regular ocular follow-up. PMID:26351311
2018-01-01
Carotid artery stenosis is relatively common and is a significant cause of ischemic stroke, but carotid revascularization can reduce the risk of ischemic stroke in patients with significant symptomatic stenosis. Carotid endarterectomy has been and remains the gold standard treatment to reduce the risk of carotid artery stenosis. Carotid artery stenting (CAS) (or carotid artery stent implantation) is another method of carotid revascularization, which has developed rapidly over the last 30 years. To date, the frequency of use of CAS is increasing, and clinical outcomes are improving with technical advancements. However, the value of CAS remains unclear in patients with significant carotid artery stenosis. This review article discusses the basic concepts and procedural techniques involved in CAS. PMID:29171201
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dondi, M.; Franchi, R.; Levorato, M.
One-hundred five hypertensive patients underwent conventional renal scintigraphy followed 2 or 3 days later by Captopril-enhanced renal scintigraphy, performed 1 hr after premedication with 50 mg of Captopril per os. All patients were then submitted to renal arteriography, performed within 15-30 days. Fifty-five patients had no renal artery stenosis, 29 had unilateral disease, and 21 bilateral. Overall, 34/37 patients were diagnosed by the provocative test as having at least one renal artery affected by a stenosis greater than 50%. Of those with no stenosis (n = 55) or stenosis less than 50% (n = 13) only two cases were falselymore » positive. Thus sensitivity was 92% and specificity 97%. For single kidney identification with stenosis greater than 50%, sensitivity of renal scintigraphy after Captopril administration was 94% and specificity 98%. Captopril enhanced renal scintigraphy is thus suggested as the first test to be performed in hypertensive patients referred for renal scintigraphic studies. Only those cases with equivocal results require a baseline study for better assessment.« less
Percutaneous Dual-valve Intervention in a High-risk Patient with Severe Aortic and Mitral Stenosis
Mrevlje, Blaz; Aboukura, Mohamad; Nienaber, Christoph A.
2016-01-01
Aortic stenosis is the most frequent and mitral stenosis is the least frequent native single-sided valve disease in Europe. Patients with the combination of severe symptomatic degenerative aortic and mitral stenosis are very rare. Guidelines for the treatment of heart valve diseases are clear for single-valve situations. However, there is no common agreement or recommendation for the best treatment strategy in patients with multiple valve disease and severe concomitant comorbidities. A 76-year-old female patient with the combination of severe degenerative symptomatic aortic and mitral stenosis and several comorbidities including severe obesity, who was found unsuitable surgical candidate by the heart team and unsuitable for two-time general anesthesia in the case of two-step single-valve percutaneous approach by anesthesiologists, underwent successful percutaneous dual-valve single-intervention (transcatheter aortic valve implantation and percutaneous mitral balloon commissurotomy). Percutaneous dual-valve single-intervention is feasible in selected symptomatic high-risk patients. PMID:27867460
Tidholm, A; Nicolle, A P; Carlos, C; Gouni, V; Caruso, J L; Pouchelon, J L; Chetboul, V
2004-04-01
A mitral valve stenosis was diagnosed in a 2-year-old female Bull Terrier by use of two-dimensional (2-D) and M-mode echocardiography, colour-flow imaging and spectral Doppler examinations. Tissue Doppler Imaging was also performed to assess the segmental radial myocardial motion. The mitral valve stenosis was characterized by a decreased mitral orifice area/left ventricle area ratio (0.14), an increased early diastolic flow velocity (E wave = 1.9 m/s), a prolonged pressure half-time (106 ms) and a decreased E-F slope (4.5 cm/s) on pulsed-wave Doppler examination. This mitral stenosis was associated with an immobile posterior leaflet, as seen on 2-D and M-mode echocardiography. Immobility of the posterior mitral leaflet is considered to be a rare finding in humans and, to our knowledge, has not been precisely documented in dogs with mitral valve stenosis.
Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A
2012-01-01
Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.
Surgical treatment of severe pulmonic stenosis under cardiopulmonary bypass in small dogs.
Fujiwara, M; Harada, K; Mizuno, T; Nishida, M; Mizukoshi, T; Mizuno, M; Uechi, M
2012-02-01
The aim of this study was to report the long-term outcome of the surgical palliation of pulmonic stenosis in dogs. The subjects comprised three female and six male dogs, mean (±sd) age: 23 (±25) months, mean (±sd) weight: 3·4 (±2·1) kg, diagnosed with severe pulmonic stenosis and right ventricular hypertrophy, with an average preoperative pressure gradient of 153 (±43) mmHg on echocardiography. The pressure overload with severe pulmonic stenosis was reduced by valvotomy, i.e., open pulmonary valve commissurotomy, with/without biomembrane patch grafting, under cardiopulmonary bypass. The postoperative pressure gradient at 1 to 7 days was significantly decreased to 65 (±39) mmHg (P<0·05). The reduced pressure gradient was maintained at 58 (±38) mmHg at final follow-up. Open valvotomy, pulmonary valve commissurotomy and biomembrane patch grafting were effective in reducing obstruction in severe pulmonic stenosis in dogs. © 2012 British Small Animal Veterinary Association.
Surgical management of benign tracheal stenosis in Basrah
Almudhafer, Muayyad M.; AI-Hassani, Fouzi A.A.; Benyan, Abdul-Khalik Z.
2013-01-01
Background: Tracheal stenosis is more frequent as a result of wide-spread use of endotracheal intubation and tracheostomy. Resection and tracheal reconstruction remain the treatment of choice in benign tracheal stenosis. Objectives: To report our experience in Basra and to identify the result of anastomosis after tracheal resection and management of those patients preoperatively and postoperatively. Methodology: A descriptive study of sixteen patients (aged 11–28 years, 10 male and 6 female) with tracheal stenosis who underwent tracheal resection and reconstruction in Basrah thoracic unit (Basra teaching hospital) from January 2008 to January 2011. Results: The result was excellent in 62.5%, good in 25%, and satisfactory in 12.5%. Postoperative complication occurred in 25% and treated successfully with no mortality. Follow-up was every 3 months for an average of 3.6 years. Conclusion: Resection and tracheal reconstruction is the treatment of choice in benign tracheal stenosis and achieved excellent results in management of the patients. PMID:25003058
Renal angiogram; Angiography - kidney; Renal angiography; Renal artery stenosis - arteriography ... an artery by a blood clot Renal artery stenosis Renal cell cancer Angiomyolipomas (noncancerous tumors of the ...
Echocardiography in mitral stenosis
Omran, A.S.; Arifi, Ahmed A.; Mohamed, A.A.
2010-01-01
Echocardiography plays a major role in diagnosis, etiology and severity of Mitral Stenosis (MS), analysis of valve anatomy and decision-making for intervention. This technique has also a crucial role to assess consequences of MS and follow up of patients after medical or surgical intervention. In this article we review the role of conventional echocardiography in assessment of mitral stenosis and future direction of this modality using 3D echocardiography. PMID:23960637
Carotid Disease Management: Surgery, Stenting, or Medication.
Khandelwal, Priyank; Chaturvedi, Seemant
2015-09-01
Internal carotid artery stenosis accounts for about 7-10 % of ischemic strokes. Conventional risk factors such as aging, hypertension, diabetes mellitus, and smoking increase the risk for carotid atherosclerosis. All patients with carotid stenosis should receive aggressive medical therapy. Carotid revascularization with either endarterectomy or stenting can benefit select patients with severe stenosis. New clinical trials will examine the contemporary role of carotid revascularization relative to optimal medical therapy.
Uchikawa, Hideki; Fujii, Katsunori; Fujita, Mayuko; Okunushi, Tomoko; Shimojo, Naoki
2017-09-01
Moyamoya syndrome is a progressive cerebrovascular disease that is characterized by stenosis of the terminal portion of the internal carotid artery and its main branches, in combination with an accompanying disease. We herein describe an 8-year-old boy exhibiting transient loss of consciousness, who had recurrent seizures in infancy with progressive brain calcification. On admission, he was alert but magnetic resonance angiography showed bilateral stenosis of the whole internal carotid artery and proliferation of vascular collaterals, and brain CT revealed calcification on bilateral putamen. Given that this fulfilled diagnostic criteria, we finally diagnosed him as having moyamoya syndrome, though the etiology was unclear. Interestingly, a whole vessel survey revealed vascular stenosis of abdominal aorta and renal arteries, in which the former has not been reported in moyamoya syndrome. We considered that brain calcification was gradually formed by decreased cerebral vascular flow from infancy, and stenosis of abdominal aorta was possibly extended from renal arteries. This is, moyamoya syndrome with brain calcification and stenosis of abdominal aorta, suggesting that morphological screening of whole vessels containing cerebral and abdominal arteries should be considered in cases of slowly progressive brain calcification. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Effects of the temporary placement of a self-expandable metallic stent in benign pyloric stenosis.
Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae
2013-07-01
The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration.
Effects of the Temporary Placement of a Self-Expandable Metallic Stent in Benign Pyloric Stenosis
Choi, Won Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae
2013-01-01
Background/Aims The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Methods Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. Results No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Conclusions Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration. PMID:23898381
Yang, Hang; Chen, Zhe; Wang, Qin-Yin; Weng, Li-Xia; Wang, Fang; Wu, Ting-Ting; Zhou, Min-Li; Bao, Yang-Yang
2017-01-01
Objective The treatment of laryngotracheal stenosis is a major therapeutic challenge. Various treatments include observation, medical management, and surgical management. The most effective surgical management is resection and reconstruction. To the authors’ knowledge, no reports have described the use of xenogenic acellular dermal matrix (ADM) for laryngotracheal stenosis. Methods A 27-year-old man presented with hemoptysis of the neck due to a traffic accident. Emergency orotracheal intubation was performed. Tracheostomy was then performed under local anesthesia. Computed tomography revealed fractures of the right thyroid cartilage and posterior arc of the cricoid cartilage and stenosis of the subglottis and first and second tracheal rings. We used a composite hyoid–sternohyoid osseomuscular flap with xenogenic ADM and a straight silicone tube as a lumen stent to reconstruct the laryngotracheal stenosis. Results Surgical recovery was uneventful. The tracheotomy opening was changed to a metal tube 5 days postoperatively. Four months postoperatively, the silicone tube was endoscopically removed under local anesthesia. The patient was decannulated 20 days later. The patient satisfied with his voice, respiration, and deglutition at the 16-month postoperative follow-up. Conclusion The use of ADM for laryngotracheal stenosis may reduce the growth of granulation tissues and promote the repair process. PMID:28480810
Yang, Hang; Chen, Zhe; Zhou, Shui-Hong; Wang, Qin-Yin; Weng, Li-Xia; Wang, Fang; Wu, Ting-Ting; Zhou, Min-Li; Bao, Yang-Yang
2017-10-01
Objective The treatment of laryngotracheal stenosis is a major therapeutic challenge. Various treatments include observation, medical management, and surgical management. The most effective surgical management is resection and reconstruction. To the authors' knowledge, no reports have described the use of xenogenic acellular dermal matrix (ADM) for laryngotracheal stenosis. Methods A 27-year-old man presented with hemoptysis of the neck due to a traffic accident. Emergency orotracheal intubation was performed. Tracheostomy was then performed under local anesthesia. Computed tomography revealed fractures of the right thyroid cartilage and posterior arc of the cricoid cartilage and stenosis of the subglottis and first and second tracheal rings. We used a composite hyoid-sternohyoid osseomuscular flap with xenogenic ADM and a straight silicone tube as a lumen stent to reconstruct the laryngotracheal stenosis. Results Surgical recovery was uneventful. The tracheotomy opening was changed to a metal tube 5 days postoperatively. Four months postoperatively, the silicone tube was endoscopically removed under local anesthesia. The patient was decannulated 20 days later. The patient satisfied with his voice, respiration, and deglutition at the 16-month postoperative follow-up. Conclusion The use of ADM for laryngotracheal stenosis may reduce the growth of granulation tissues and promote the repair process.
Motegi, Emi; Hasegawa, Kiyoshi; Kawai, Satoshi; Kiuchi, Kaori; Kosaka, Nobuaki; Mochizuki, Yoshiko; Fukasawa, Ichio
2016-03-09
Several approaches for treating severe uterine cervical stenosis after conization for cervical intraepithelial neoplasia have been reported; yet, the condition can still be difficult to treat successfully. We performed uterine cervical dilation surgery in two patients with severe stenosis, followed by insertion of the levonorgestrel-releasing intrauterine system, which is used for dysmenorrhea or endometriosis-related pain because of its strong progesterone activity. Patient 1 was a 34-year-old Japanese woman who was diagnosed with dysmenorrhea caused by recurrent uterine cervical stenosis and hematometra after laser conization. Patient 2 was a 44-year-old Japanese woman who developed dysmenorrhea and prolonged menstruation caused by uterine cervical stenosis without hematometra. After providing informed consent, they underwent cervical dilation surgery followed by insertion of the levonorgestrel-releasing intrauterine system. After treatment, their symptoms immediately improved, and after removal of their devices, they remained asymptomatic. To the best of our knowledge, this is the first report to confirm the usefulness and easy applicability of the levonorgestrel-releasing intrauterine system for uterine cervical stenosis. Although we had success with the method, this study of two patients is preliminary. Further study with larger numbers of patients is necessary to confirm the usefulness of our technique.
Fu, Chunli; Xing, Yingqi; Song, Xiaonan
2011-04-01
To investigate the association of single nucleotide polymorphism in the matrix metalloproteinase-3 (MMP3) gene promoter with the susceptibility to the middle cerebral artery stenosis. A case-control study was performed by determining the genotype of MMP3 gene promoter region using polymerase chain reaction-restriction fragment length polymorphism in 119 patients with middle cerebral artery stenosis documented by transcranial Doppler compared to 92 control patients. The frequencies of 5A and 6A alleles in MMP3 promoter region were 16.0 and 84.0% respectively in case group compared to 15.8 and 84.2% in control group with no significant difference between the two groups (P > 0.05). No significant difference was also observed in the distribution of genotypes 5A/5A,5A/6A, and 6A/6A between middle cerebral artery stenosis and control groups. Compared to 5A/5A + 5A/6A genotypes,the 6A/6A genotype did not significantly modify the risk of developing the middle cerebral artery stenosis. The MMP3-1171 dupA promoter polymorphisms are not valuable markers of susceptibility of the middle cerebral artery stenosis in this sample of population studied.
Koëter, Marijn; van der Sangen, Maurice J C; Hurkmans, Coen W; Luyer, Misha D P; Rutten, Harm J T; Nieuwenhuijzen, Grard A P
2015-03-06
Neoadjuvant chemoradiation might increase anastomotic leakage and stenosis in patients with esophageal cancer treated with neoadjuvant chemoradiation and esophagectomy. The aim of this study was to determine the influence of radiation dose on the incidence of leakage and stenosis. Fifty-three patients with esophageal cancer received neoadjuvant chemoradiation (23 × 1.8 Gy) (combined with Paclitaxel and Carboplatin) followed by a transhiatal esophagectomy between 2009 and 2011. On planning CT, the future anastomotic region was determined and the mean radiation dose, V20, V25, V30, V35 and V40 were calculated. Logistic regression analysis was conducted to examine determinants of anastomotic leakage and stenosis. Anastomotic leaks occurred in 13 of 53 patients (25.5%) and anastomotic stenosis occurred in 24 of 53 patients (45.3%). Median follow-up was 20 months. Logistic regression analysis showed that mean dose, V20-V40, age, co-morbidity, method of anastomosis, operating time and interval between last radiotherapy treatment and surgery were not predictors of anastomotic leakage and stenosis. A radiation dose of 23 × 1.8 Gy on the future anastomotic region has no influence on the occurrence of anastomotic leakage and stenosis in patients with esophageal cancer treated with neoadjuvant chemoradiation followed by transhiatal esophagectomy.
Wagle, Prasad; Yadav, Kamal Sunder; Sali, Priyanka Akhilesh; Garg, Raman; Varty, Paresh
2017-02-01
Pancreatico-enteric anastomotic (PEA) stenosis is one of the late complications following pancreaticoduodenectomy (PD) and reported for benign diseases. Literature for PEA stenosis following PD for malignancy is very limited due to low survival. Patients undergoing surgery for symptomatic, recurrent, obstructive pancreatitis due to PEA stenosis following PD for malignancy were retrospectively identified from the authors' prospective database between January 1997 and December 2014. Six patients with median age 56.5 years underwent revision surgery for PEA stenosis during this time period. At primary PD, all were node negative with T1/T2 disease. The primary PEA were pancreatico-jejunostomy (PJ) (n = 5) and pancreatico-gastrostomy (n = 1). Median time to develop symptoms was 62 months. At revision surgery, a Roux-en-Y longitudinal PJ (n = 5) and an end-to-side PJ (n = 1) were done. With a median follow-up of 36 months, pain relief was excellent (n = 5) to average (n = 1). With improving long-term survival in patients undergoing PD for malignancy more such patients will be identified in future. Patients with symptomatic PEA stenosis following PD for malignancy can be managed surgically, with excellent outcomes in centers of expertise in pancreatic surgery.
Radnic, Bojana; Radojevic, Nemanja; Vucinic, Jelena; Duborija-Kovacevic, Natasa
2017-07-01
Most young patients with mild-to-moderate aortic stenosis show no symptoms, and sudden death appears only occasionally. We hypothesised that malignant ventricular arrhythmias could be responsible for the high incidence of sudden death in such patients. If multiple factors such as asymptomatic aortic stenosis in association with arrhythmia-provoking agents are involved, could it be sufficient to account for sudden unexpected death? In this study, eight cases of sudden death in young adults, with ages ranging from 22 to 36 years, who had never reported any symptoms that could be related to aortic stenosis, were investigated. Full autopsies were performed, and congenital aortic stenosis in all eight cases was confirmed. DNA testing for channelopathies was negative. Comprehensive toxicological analyses found an electrolyte imbalance, or non-toxic concentrations of amitriptyline, terfenadine, caffeine, and ethanol. Collectively, these results suggest that congenital asymptomatic aortic stenosis without cardiac hypertrophy in young adults is not sufficient to cause sudden death merely on its own; rather, an additional provoking factor is necessary. According to our findings, the provoking factor may be a state of physical or emotional stress, a state of electrolyte imbalance, or even taking a therapeutic dose of a particular drug.
Alnawaiseh, M; Böhm, M R R; Rosentreter, A; Wieneke, A C; Wirths, G; Merté, R L; Eter, N; Zumhagen, L
2016-06-01
Traumatic lacrimal duct stenosis can be the result of sharp trauma of the eyelid, indirect trauma or surgery in the nasoorbital region, as well as burns, chemotherapy and radiation of the facial region. The aim of the study is to present the demographics, patient satisfaction, and course of different surgical procedures for secondary treatment of traumatic lacrimal duct stenosis. We retrospectively reviewed the medical records of 50 patients who required surgery for traumatic lacrimal duct stenosis from 2009 to 2011 at the University Eye Hospital in Muenster. The evaluation included the following criteria: age, sex, duration of symptoms, complication rate and the rate of recurrence. We systematically evaluated the medical data and asked the patients about the recent symptoms via telephone questionnaire. 60 eyes of 50 patients were included (18 women; 32 men; age: 51.8 ± 17.1 years); 34 eyes (56.7 %) had already had operations of the lacrimal system. The success rate was 58.1 %. The mean postoperative follow-up was 52.3 ± 10.7 months. In 11 cases (18.3 %), a dakryocystorhinostomy (DCR) was necessary. Traumatic lacrimal stenosis is more common in men, and has a poorer prognosis than lacrimal duct stenosis from other causes. Georg Thieme Verlag KG Stuttgart · New York.
Endoscopic diode laser welding of mucosal grafts on the larynx: a new technique.
Wang, Z; Pankratov, M M; Rebeiz, E E; Perrault, D F; Shapshay, S M
1995-01-01
Epithelial coverage of a laryngotracheal wound is an important factor in preventing stenosis, and endoscopic transplantation of a free mucosal graft without stents or sutures would be a significant therapeutic advance. In vitro and in vivo canine studies were performed to explore the feasibility of transplantation with a low-power diode laser (400 mW) enhanced by indocyanine green dye-doped albumin. The tensile strength of graft adherence in 10 cadaver larynges was strong (35.25 +/- 10.39 g). Survival studies in live canine models with a specially designed endoscopic instrument set showed excellent healing at 6, 14, and 28 days. Healing was documented with photography and by histologic examination. Successful endoscopic transplantation of a free mucosal graft should improve results of treatment for laryngotracheal stenosis and laryngeal reconstructive surgery.
Kim, Kyung Rae; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki
2011-04-01
The purpose of this study was to evaluate the efficacy and safety of stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. From September 1995 to April 2007, percutaneous transhepatic portal venous stent placement was attempted in 19 patients with postoperative portal venous stenosis. Portal venous stenosis was a complication of surgery in 11 patients and caused by tumor recurrence in eight patients. The clinical manifestations were ascites, hematochezia, melena, esophageal varices, and abnormal liver function. Stents were placed in the stenotic or occluded lesions after percutaneous transhepatic portography. Technical and clinical success, stent patency, and complications were evaluated. Stent placement was successful in 18 patients (technical success rate, 95%). Clinical manifestations improved in 16 patients (clinical success rate, 84%). The mean patency period among the 18 patients with technical success was 21.3 ± 23.2 months. The mean patency period of the benign stenosis group (30.1 ± 25.6 months) was longer than that of the tumor recurrence group (7.3 ± 7.7 months), and the difference was statistically significant (p = 0.038). There were two cases of a minor complication (transient fever) and three cases of major complications (septicemia, liver abscess, and acute portal venous thrombosis). Percutaneous transhepatic stent placement can be safe and effective in relieving portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. Patients with benign stenosis had more favorable results than did those with tumor recurrence.
Lang, Gernot; Perrech, Moritz; Navarro-Ramirez, Rodrigo; Hussain, Ibrahim; Pennicooke, Brenton; Maryam, Farah; Avila, Mauricio J; Härtl, Roger
2017-05-01
Extreme lateral interbody fusion (ELIF) is a powerful tool for interbody fusion and coronal deformity correction. However, evidence regarding the success of ELIF in decompressing foraminal, lateral recess, and central canal stenosis is lacking. We performed a systematic review of current literature on the potential and limitations of ELIF to indirectly decompress neural elements. A literature search using PubMed, Cochrane, and ScienceDirect databases was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. Information on study design, sample size, population, procedure, number and location of involved levels, follow-up time, and complications as well as information on conflict of interest was extracted and evaluated. We selected 20 publications including 1080 patients for review. Most publications (90%) were retrospective case series. Most frequent indications for ELIF included degenerative disc disease, spinal stenosis, spondylolisthesis, and degenerative scoliosis. Most studies revealed significant improvement in radiographic and clinical outcome after ELIF. Mean foraminal area, central canal area, and subarticular diameter increased by 31.6 mm 2 , 28.5 mm 2 , and 0.85 mm. ELIF successfully improved foraminal stenosis. Contradictory results were found for indirect decompression of central canal stenosis. Data on lateral recess stenosis were scarce. Current data suggest ELIF to be an efficient technique in decompression of foraminal stenosis. Evidence on decompression of central canal or lateral recess stenosis via ELIF is low, and results are inconsistent. Most studies are limited by study design, sample size, and potential conflicts of interest. Copyright © 2017 Elsevier Inc. All rights reserved.
Golchehr, Bahar; Holewijn, Suzanne; Kruse, Rombout R; van Walraven, Laurens A; Zeebregts, Clark J; Reijnen, Michel M P J
2015-09-01
The role of endografts in the treatment of extensive superficial femoral artery (SFA) occlusive disease is enlarging. Results are limited by the occurrence of edge stenosis. The aim of the study was to retrospectively evaluate the efficacy of treatment of edge stenosis of endografts inserted for SFA occlusive disease. All patients, treated between November 2001 and December 2011, with a self-expandable polytetrafluoroethylene-endograft were gathered in a prospective database in three hospitals. The incidence of primary edge stenosis and the incidence of re-edge stenosis after treatment were retrospectively noted and a comparison was made between the results of percutaneous transluminal angioplasty (PTA) and extension of the endograft. A total of 88 patients presented with 115 edge stenoses, of which the majority presented within 1 year after insertion of the endograft (mean time to edge stenosis 10.7 ± 8.2 months). Seventy-three stenoses (63%) manifested at the proximal and 42 at the distal edge (37%). The 1-year incidence of restenosis and/or occlusion was 45% after PTA and 43% after endograft extension, with 1-year patency rates of 81% and 92%, respectively. The incidence of restenosis/occlusion after treatment with PTA was 12% higher at two years compared to extension of the endograft (55% vs. 43%, respectively). Edge stenosis may well be treated with either PTA or extension of the endograft. The incidence of restenosis and/or occlusion after both PTA and extension is high, but patency rates are acceptable. Aggressive surveillance is needed during the first year after insertion. © 2015 Wiley Periodicals, Inc.
Rozeman, Anouk D; Hund, Hajo; Westein, Michel; Wermer, Marieke J H; Lycklama À Nijeholt, Geert J; Boiten, Jelis; Schimsheimer, Robert-Jan; Algra, Ale
2017-08-01
Vertebrobasilar stenosis is frequent in patients with posterior circulation stroke and it increases risk of recurrence. We investigated feasibility of duplex ultrasonography (DUS) for screening for extracranial vertebral artery stenosis and compared it with CT angiography (CTA). We gathered data on 337 consecutive patients who had DUS because of posterior circulation stroke or TIA. Matching CTA studies were retrieved and used as reference. Stenosis on CTA was considered "significant" if >50%, at DUS if Peak Systolic Velocity (PSV) > 140 cm/s for the V1 segment and PSV > 125 cm/s for the V2 segment. We determined the area under the ROC curve (AUROC). In addition, we calculated which PSV cut-off value resulted in highest sensitivity with acceptable specificity. DUS was able to make an adequate measurement in 378 of 674 V1 segments and 673 of 674 V2 segments. DUS detected a significant stenosis in 52 of 378 V1 segments; 12 were confirmed by CTA (AUROC 0.73, 95% Confidence Interval 0.63-0.83). The optimal DUS PSV cut-off value for this segment was 90 cm/s. For the V2 segment there were too few stenoses to allow reliable assessment of diagnostic characteristics of DUS. Although DUS has a fair AUROC for detecting significant stenosis, adequate assessment of the V1 segment is often not possible due to anatomic difficulties. Assessment of the V2 segment is feasible but yielded few stenoses. Hence, we consider usefulness of DUS for screening of extracranial vertebral artery stenosis limited.
Yoon, Hakyoung; Kim, Jaehwan; Nahm, Sang-Soep; Eom, Kidong
2017-07-11
Congenital pulmonary valve stenosis and patent ductus arteriosus are common congenital heart defects in dogs. However, concurrence of atypical pulmonary valve stenosis and patent ductus arteriosus is uncommon. This report describes the anatomic, histopathologic, and echocardiographic features in a dog with concomitant pulmonary valve stenosis and patent ductus arteriosus with atypical pulmonary valve dysplasia that included a fibrous band of tissue. A 1.5-year-old intact female Chihuahua dog weighing 3.3 kg presented with a continuous grade VI cardiac murmur, poor exercise tolerance, and an intermittent cough. Echocardiography indicated pulmonary valve stenosis, a thickened dysplastic valve without annular hypoplasia, and a type IIA patent ductus arteriosus. The pulmonary valve was thick line-shaped in systole and dome-shaped towards the right ventricular outflow tract in diastole. The dog suffered a fatal cardiac arrest during an attempted balloon pulmonary valvuloplasty. Necropsy revealed pulmonary valve dysplasia, commissural fusion, and incomplete opening and closing of the pulmonary valve because of a fibrous band of tissue causing adhesion between the right ventricular outflow tract and the dysplastic intermediate cusp of the valve. A fibrous band of tissue between the right ventricular outflow track and the pulmonary valve should be considered as a cause of pulmonary valve stenosis. Pulmonary valve stenosis and patent ductus arteriosus can have conflicting effects on diastolic and systolic dysfunction, respectively. Therefore, beta-blockers should always be used carefully, particularly in patients with a heart defect where there is concern about left ventricular systolic function.
Minors, Sandra L; O'Grady, Michael R; Williams, Regan M; O'Sullivan, M Lynne
2006-01-01
Primary infundibular stenosis is a rare congenital defect in which the right ventricle is divided into a proximal "high-pressure" chamber and a distal "low-pressure" chamber. The condition can be misdiagnosed as ventricular septal defect or valvular pulmonic stenosis and the disease severity underestimated. The purpose of this study was to provide a detailed clinical and echocardiographic description of this anomaly in a series of dogs. Several anatomic forms of infundibular stenosis exist. High resolution two-dimensional echocardiography could differentiate 3 gross anatomic substrates. Knowledge of the anatomy of the obstructing lesion could influence options for corrective interventions. Thirteen dogs examined at the Ontario Veterinary College teaching hospital from 1994 to 2005 with an ultrasound diagnosis of subpulmonic stenasis. A retrospective review was made of case records from 1994 to 2005. Thirteen dogs were identified as having primary infundibular stenosis, with apparent increased prevalence in Golden Retrievers (8/13, 62%) and Siberian Huskies (3/13, 23%). Three types of infundibular lesions were identified by ultrasound in 11/13 dogs: a fibrous diaphragm (6), fibromuscular (4), and muscular obstruction (1). Two dogs with a fibrous diaphragm underwent direct surgical dilation without the use of cardiopulmonary bypass or inflow occlusion, resulting in substantial reduction of the severity of stenosis. Accurate determination of the severity of the stenosis and the anatomy of the obstructing lesion are important in devising a treatment strategy. Recognition of the fibrous diaphragm by echocardiography identifies a subset of dogs potentially amenable to surgical dilation without the need for cardiopulmonary bypass.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tapping, C. R.; Ahmed, M.; Scott, P. M.
The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 {+-} 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included pairedmore » Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 {+-} -0.15 (right) and 0.61 {+-} -0.16 (left). After the procedure they were 0.86 {+-} -0.07 (right) and 0.90 {+-} -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic disease.« less
Dejerome, C; Grange, C; De Laforcade, L; Bonin, O; Laville, M; Lermusiaux, P; Long, A
2018-05-01
Duplex ultrasonography screening for renal artery stenosis has been the object of guidelines published by four societies designed to optimize the cost-effectiveness of the examination. To determine how well guideline indications for ultrasonography matched with requests and results in our university hospital; to determine whether compliance with guidelines was predictive of renal artery stenosis; to identify guidelines predictive of presence of stenosis; and to determine whether other predictive factors can be recognized. Requests and results of 450 Duplex ultrasonography examinations of the renal arteries performed from January 1st 2014 to December 31st 2015 were compared with published guidelines. At least one guideline indication was identified for 212 of the 450 examinations performed (47.1%). Among these examinations, renal artery stenosis≥70% was identified in 18 patients (8.0%). No case of stenosis was identified during examinations performed outside guideline indications. Factors predictive of stenosis were: compliance with guidelines (OR=21.86 [2.88; 165.8]). Predictive guidelines were: resistant hypertension in spite of appropriate treatment (OR=3.85, [1.44; 10.33], P=0.011), accelerated hypertension (OR=7.30, [1.40; 37.99], P=0.049), sudden unexplained pulmonary edema (OR=7.30, [1.40; 37.99], P=0.049), unexplained renal insufficiency (OR=3.58, [1.37; 9.37], P=0.011), unexplained renal hypotrophy (OR=16.69, [4.38; 63.69], P<0.001), renal asymmetry (OR=4.32, [1.45; 12.85], P<0.016). No other factor was predictive of renal stenosis. These examinations had therapeutic consequences in only 50% of patients. This study confirms the relevance of published guidelines. The diagnostic-effectiveness of Duplex ultrasonography examinations to search for renal artery stenosis depends upon compliance with these guidelines. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Chaturvedi, S; Bruno, A; Feasby, T; Holloway, R; Benavente, O; Cohen, S N; Cote, R; Hess, D; Saver, J; Spence, J D; Stern, B; Wilterdink, J
2005-09-27
To assess the efficacy of carotid endarterectomy for stroke prevention in asymptomatic and symptomatic patients with internal carotid artery stenosis. Additional clinical scenarios, such as use of endarterectomy combined with cardiac surgery, are also reviewed. The authors selected nine important clinical questions. A systematic search was performed for articles from 1990 (the year of the last statement) until 2001. Additional articles from 2002 through 2004 were included using prespecified criteria. Two reviewers also screened for other relevant articles from 2002 to 2004. Case reports, review articles, technical studies, and single surgeon case series were excluded. For several questions, high quality randomized clinical trials had been completed. Carotid endarterectomy reduces the stroke risk compared to medical therapy alone for patients with 70 to 99% symptomatic stenosis (16% absolute risk reduction at 5 years). There is a smaller benefit for patients with 50 to 69% symptomatic stenosis (absolute risk reduction 4.6% at 5 years). There is a small benefit for asymptomatic patients with 60 to 99% stenosis if the perioperative complication rate is low. Aspirin in a dose of 81 to 325 mg per day is preferred vs higher doses (650 to 1,300 mg per day) in patients undergoing endarterectomy. Evidence supports carotid endarterectomy for severe (70 to 99%) symptomatic stenosis (Level A). Endarterectomy is moderately useful for symptomatic patients with 50 to 69% stenosis (Level B) and not indicated for symptomatic patients with <50% stenosis (Level A). For asymptomatic patients with 60 to 99% stenosis, the benefit/risk ratio is smaller compared to symptomatic patients and individual decisions must be made. Endarterectomy can reduce the future stroke rate if the perioperative stroke/death rate is kept low (<3%) (Level A). Low dose aspirin (81 to 325 mg) is preferred for patients before and after carotid endarterectomy to reduce the rate of stroke, myocardial infarction, and death (Level A).
Raper, Daniel M S; Buell, Thomas J; Ding, Dale; Pomeraniec, I Jonathan; Crowley, R Webster; Liu, Kenneth C
2018-01-01
Safety and efficacy of superior sagittal sinus (SSS) stenting for non-thrombotic intracranial venous occlusive disease (VOD) is unknown. The aim of this retrospective cohort study is to evaluate outcomes after SSS stenting. We evaluated an institutional database to identify patients who underwent SSS stenting. Radiographic and clinical outcomes were analyzed and a novel angiographic classification of the SSS was proposed. We identified 19 patients; 42% developed SSS stenosis after transverse sinus stenting. Pre-stent maximum mean venous pressure (MVP) in the SSS of 16.2 mm Hg decreased to 13.1 mm Hg after stenting (p=0.037). Preoperative trans-stenosis pressure gradient of 4.2 mm Hg decreased to 1.5 mm Hg after stenting (p<0.001). No intraprocedural complication or junctional SSS stenosis distal to the stent construct was noted. Improvement in headache, tinnitus, and visual obscurations was reported by 66.7%, 63.6%, and 50% of affected patients, respectively, at mean follow-up of 5.2 months. We divided the SSS into four anatomically equal segments, numbered S1-S4, from the torcula to frontal pole. SSS stenosis typically occurs in the S1 segment, and the anterior extent of SSS stents was deployed at the S1-S2 junction in all but one case. SSS stenting is reasonably safe, may improve clinical symptoms, and significantly reduces maximum MVP and trans-stenosis pressure gradients in patients with VOD with SSS stenosis. The S1 segment is most commonly stenotic, and minimum pressure gradients for symptomatic SSS stenosis may be lower than for transverse or sigmoid stenosis. Additional studies and follow-up are necessary to better elucidate appropriate clinical indications and long-term efficacy of SSS stenting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Miao, Zhongrong; Zhang, Yong; Shuai, Jie; Jiang, Changchun; Zhu, Qiyi; Chen, Kangning; Liu, Li; Li, Baomin; Shi, Xiangqun; Gao, Lianbo; Liu, Yajie; Wang, Feng; Li, Yongli; Liu, Tieyan; Zheng, Hongbo; Wang, Yilong; Wang, Yongjun
2015-10-01
Although recent trials have suggested that stenting is worse than medical therapy for patients with severe symptomatic intracranial atherosclerotic stenosis, it is not clear whether this conclusion applies to a subset of patients with hypoperfusion symptoms. To justify for a new trial in China, we performed a multicenter prospective registry study to evaluate the safety and efficacy of endovascular stenting within 30 days for patients with severe symptomatic intracranial atherosclerotic stenosis. Patients with symptomatic intracranial atherosclerotic stenosis caused by 70% to 99% stenosis combined with poor collaterals were enrolled. The patients were treated either with balloon-mounted stent or with balloon predilation plus self-expanding stent as determined by the operators following a guideline. The primary outcome within 30 days is stroke, transient ischemic attack, and death after stenting. The secondary outcome is successful revascularization. The baseline characteristics and outcomes of the 2 treatment groups were compared. From September 2013 to January 2015, among 354 consecutive patients, 300 patients (aged 58.3±9.78 years) were recruited, including 159 patients treated with balloon-mounted stent and 141 patients with balloon plus self-expanding stent. The 30-day rate of stroke, transient ischemic attack, and death was 4.3%. Successful revascularization was 97.3%. Patients treated with balloon-mounted stent were older, less likely to have middle cerebral artery lesions, more likely to have vertebral artery lesions, more likely to have Mori A lesions, less likely to have Mori C lesions, and likely to have lower degree of residual stenosis than patients treated with balloon plus self-expanding stent. The short-term safety and efficacy of endovascular stenting for patients with severe symptomatic intracranial atherosclerotic stenosis in China is acceptable. Balloon-mounted stent may have lower degree of residual stenosis than self-expanding stent. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01968122. © 2015 American Heart Association, Inc.
Guo, W-Y; Lee, C-C J; Lin, C-J; Yang, H-C; Wu, H-M; Wu, C-C; Chung, W-Y; Liu, K-D
2017-01-01
Sinus stenosis occasionally occurs in dural arteriovenous fistulas. Sinus stenosis impedes venous outflow and aggravates intracranial hypertension by reversing cortical venous drainage. This study aimed to analyze the likelihood of sinus stenosis and its impact on cerebral hemodynamics of various types of dural arteriovenous fistulas. Forty-three cases of dural arteriovenous fistula in the transverse-sigmoid sinus were reviewed and divided into 3 groups: Cognard type I, type IIa, and types with cortical venous drainage. Sinus stenosis and the double peak sign (occurrence of 2 peaks in the time-density curve of the ipsilateral drainage of the internal jugular vein) in dural arteriovenous fistula were evaluated. "TTP" was defined as the time at which a selected angiographic point reached maximum concentration. TTP of the vein of Labbé, TTP of the ipsilateral normal transverse sinus, trans-fistula time, and trans-stenotic time were compared across the 3 groups. Thirty-six percent of type I, 100% of type IIa, and 84% of types with cortical venous drainage had sinus stenosis. All sinus stenosis cases demonstrated loss of the double peak sign that occurs in dural arteriovenous fistula. Trans-fistula time (2.09 seconds) and trans-stenotic time (0.67 seconds) in types with cortical venous drainage were the most prolonged, followed by those in type IIa and type I. TTP of the vein of Labbé was significantly shorter in types with cortical venous drainage. Six patients with types with cortical venous drainage underwent venoplasty and stent placement, and 4 were downgraded to type IIa. Sinus stenosis indicated dysfunction of venous drainage and is more often encountered in dural arteriovenous fistula with more aggressive types. Venoplasty ameliorates cortical venous drainage in dural arteriovenous fistulas and serves as a bridge treatment to stereotactic radiosurgery in most cases. © 2017 by American Journal of Neuroradiology.
Bashar, Khalid; Healy, Donagh; Clarke-Moloney, Mary; Burke, Paul; Kavanagh, Eamon; Walsh, Stewart-Redmond
2014-01-01
Introduction Radiation arteritis following neck irradiation as a treatment for head and neck malignancy has been well documented. The long-term sequelae of radiation exposure of the carotid arteries may take years to manifest clinically, and extra-cranial carotid artery (ECCA) stenosis is a well-recognised vascular complication. These carotid lesions should not be regarded as benign and should be treated in the same manner as standard carotid stenosis. Previous studies have noted increased cerebrovascular events such as stroke in this cohort of patients because of high-grade symptomatic carotid stenosis resulting in emboli. Aim To evaluate the effect of radiation therapy on ECCA atherosclerosis progression. Methods Online search for case-control studies and randomised clinical trials that reported on stenosis in extra-cranial carotid arteries in patients with neck malignancies who received radiation therapy (RT) comparing them to patients with neck malignancies who did not receive RT. Results Eight studies were included in the final analysis with total of 1070 patients – 596 received RT compared to 474 in the control group. There was statistically significant difference in overall stenosis rate (Pooled risk ratio = 4.38 [2.98, 6.45], P = 0.00001) and severe stenosis (Pooled risk ratio = 7.51 [2.78, 20.32], P <0.0001), both being higher in the RT group. Pooled analysis of the five studies that reported on mild stenosis also showed significant difference (Pooled risk ratio = 2.74 [1.75, 4.30], 95% CI, P = 0.0001). Conclusion The incidence of severe ECCA stenosis is higher among patients who received RT for neck malignancies. Those patients should be closely monitored and screening programs should be considered in all patients who receive neck RT. PMID:25329500
Zhong, Xue-mei; Zhang, Yan-ling; Li, Long
2012-08-01
Congenital esophageal stenosis owing to tracheobronchial remnants (TBR) is a rare condition. This study was conducted to understand the clinical features of TBR. The data of the four cases with TBR admitted to our hospital and 76 patients identified from the literature were reviewed. The clinical manifestation, X-ray, endoscopy, biopsy and treatment were studied retrospectively. Of the total of 80 cases, 45 were male, 33 were female, and for 2 cases the gender was unknown. Symptoms of dysphagia and regurgitation developed at the age of 1-day to 12-month. Definitive treatment was carried out at the age of 1-month to 16-year. Twenty-seven patients had associated anomalies with esophageal atresia being the most prevalent. X-ray esophagography showed segmental stenosis at the distal third of the esophagus in all patients except three. An abrupt narrow segment at the lower esophagus with marked proximal dilatation was found in 32 cases. Esophagography of 12 cases showed distal esophageal stenosis with tapered narrowing. Esophagography of 20 cases showed flask-shaped shadow of distal esophageal stenosis and one patient showed linear projection of barium at the level of stenosis. Endoscopy found almost complete obstruction of the lower esophageal lumen without signs of the esophagitis or reflux. Esophagoscopic dilatation of the stenosis was attempted in 24 cases, but was ineffective, and 3 patients suffered esophageal perforation. Seventy-nine patients underwent resection of the stenotic segment. Histologic examination of the resected specimen showed cartilage, mucus glands, resembling bronchal tissue. Post-operative complication included anastomotic stenosis, anastomotic leakage, hiatal hernia, and gastroesophageal reflux. TBR should be suspected in patients who present with a typical history of dysphagia after ingestion of solid food. Esophagography and esophagoscopy are the essential means for diagnosis. TBR should be different from achalasia and should be diagnosed by biopsy. Operation is the only choice of treatment.
Xia, Yun; Yan, Shuangqian; Zhang, Xian; Ma, Peng; Du, Wei; Feng, Xiaojun; Liu, Bi-Feng
2017-03-21
Digital loop-mediated isothermal amplification (dLAMP) is an attractive approach for absolute quantification of nucleic acids with high sensitivity and selectivity. Theoretical and numerical analysis of dLAMP provides necessary guidance for the design and analysis of dLAMP devices. In this work, a mathematical model was proposed on the basis of the Monte Carlo method and the theories of Poisson statistics and chemometrics. To examine the established model, we fabricated a spiral chip with 1200 uniform and discrete reaction chambers (9.6 nL) for absolute quantification of pathogenic DNA samples by dLAMP. Under the optimized conditions, dLAMP analysis on the spiral chip realized quantification of nucleic acids spanning over 4 orders of magnitude in concentration with sensitivity as low as 8.7 × 10 -2 copies/μL in 40 min. The experimental results were consistent with the proposed mathematical model, which could provide useful guideline for future development of dLAMP devices.
Surgical results of mitral valve repair for congenital mitral valve stenosis in paediatric patients.
Cho, Sungkyu; Kim, Woong-Han; Kwak, Jae Gun; Lee, Jeong Ryul; Kim, Yong Jin
2017-12-01
Mitral valve (MV) repairs have been performed in paediatric patients with congenital MV stenosis. However, congenital MV stenosis lesions are a heterogeneous group of lesions, and their repair remains challenging. From March 1999 to September 2014, MV repair was performed in 22 patients with congenital MV stenosis. The median age was 10.3 months (ranging from 22 days to 9.1 years), and the mean body weight was 7.9 ± 4.0 kg at the time of the operation. Multiple-level left-side heart obstructions were present in 9 (45%) patients. The main aetiology of the mitral stenosis was a supravalvular mitral ring in 8 patients, valvular stenosis in 4 patients, a parachute deformity of the papillary muscles in 4 patients and other abnormal papillary muscles in 6 patients. The mean MV pressure gradient improved from 10.4 ± 3.9 mmHg to 3.4 ± 1.7 mmHg after MV repair (n = 18, P < 0.0001). The mean follow-up duration was 6.7 ± 5.4 years. One patient died postoperatively due to septic shock. Four patients required a second operation (2 patients for mitral stenosis, 1 patient for left ventricular outflow tract obstruction and mitral stenosis and 1 patient for mitral regurgitation). Among them, 2 patients died: 1 patient died due to cardiopulmonary bypass weaning failure and another patient died due to multiple cerebral infarcts. At the last follow-up, the mean MV pressure gradient was 4.5 ± 3.1 mmHg for all patients who did not have reoperation, and moderate or greater mitral insufficiency was detected in 3 patients. At 10 years, the survival rate was 85.9 ± 7.6%, and the freedom from reoperation rate was 77.5 ± 10.1%. In the log-rank test, MV repair in the neonate was associated with mortality (P = 0.010), and presentation of mitral insufficiency was associated with reoperation (P = 0.003). MV repair in paediatric patients with congenital mitral stenosis showed acceptable results. The follow-up echocardiogram also revealed satisfactory results. Close follow-up is necessary to detect the development of postoperative mitral stenosis or regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Leng, Xinyi; Scalzo, Fabien; Ip, Hing Lung; Johnson, Mark; Fong, Albert K.; Fan, Florence S. Y.; Chen, Xiangyan; Soo, Yannie O. Y.; Miao, Zhongrong; Liu, Liping; Feldmann, Edward; Leung, Thomas W. H.; Liebeskind, David S.; Wong, Ka Sing
2014-01-01
Background Patients with symptomatic intracranial atherosclerosis (ICAS) of ≥70% luminal stenosis are at high risk of stroke recurrence. We aimed to evaluate the relationships between hemodynamics of ICAS revealed by computational fluid dynamics (CFD) models and risk of stroke recurrence in this patient subset. Methods Patients with a symptomatic ICAS lesion of 70–99% luminal stenosis were screened and enrolled in this study. CFD models were reconstructed based on baseline computed tomographic angiography (CTA) source images, to reveal hemodynamics of the qualifying symptomatic ICAS lesions. Change of pressures across a lesion was represented by the ratio of post- and pre-stenotic pressures. Change of shear strain rates (SSR) across a lesion was represented by the ratio of SSRs at the stenotic throat and proximal normal vessel segment, similar for the change of flow velocities. Patients were followed up for 1 year. Results Overall, 32 patients (median age 65; 59.4% males) were recruited. The median pressure, SSR and velocity ratios for the ICAS lesions were 0.40 (−2.46–0.79), 4.5 (2.2–20.6), and 7.4 (5.2–12.5), respectively. SSR ratio (hazard ratio [HR] 1.027; 95% confidence interval [CI], 1.004–1.051; P = 0.023) and velocity ratio (HR 1.029; 95% CI, 1.002–1.056; P = 0.035) were significantly related to recurrent territorial ischemic stroke within 1 year by univariate Cox regression, respectively with the c-statistics of 0.776 (95% CI, 0.594–0.903; P = 0.014) and 0.776 (95% CI, 0.594–0.903; P = 0.002) in receiver operating characteristic analysis. Conclusions Hemodynamics of ICAS on CFD models reconstructed from routinely obtained CTA images may predict subsequent stroke recurrence in patients with a symptomatic ICAS lesion of 70–99% luminal stenosis. PMID:24818753
Woodacre, Timothy; Sewell, Matthew; Clarke, Andrew J; Hutton, Mike
2016-01-01
Spinal stenosis can be a very disabling condition. Surgical decompression carries a risk of dural tear and neural injury, which is increased in patients with severe stenosis or an atypical anatomy. We present an unusual case of symptomatic stenosis secondary to achondroplasia presenting in a paediatric patient, and highlight a new surgical technique used to minimise the risk of dural and neural injury during decompression. PMID:27288205
Hiatal Stenosis After Laparoscopic Nissen Fundoplication: A Report of 2 Cases
Selima, Mohamed A.; Awad, Ziad T.
2002-01-01
Persistent postoperative dysphagia (PPD) is one of the most troublesome complications of laparoscopic antire-flux surgery. Hiatal stenosis, although rare, is a serious complication and is one of the causes of PPD after antire-flux procedures. In the 2 presented patients, progressive dysphagia started immediately after the antireflux procedure and did not respond to esophageal dilations. The cause of dysphagia in both patients was hiatal stenosis and was corrected laparoscopically. PMID:12500845
Bernheim, J; Aronheim, M; Griffel, B
1983-01-01
The authors report 25 cases of primary stenosis of the pyelo-ureteric junction (PUJ) in terms of their clinical and histological features. Based on a semi-quantitative study of the histological modifications, the authors attempt to determine whether these modifications are primary and therefore responsible for the stenosis of the PUJ or wether, on the contrary, these changes are secondary to the stenosis. After studying 25 children and adults, it appears that these histological signs are primary and responsible for the malformation: rarefaction of the muscle layers (24 cases out of 25), fibrosis of the sub-mucosa or intermuscular layer in every case, presence of valvular mucosal folds in every case but one.
[A Case of Middle Cerebral Artery Stenosis Presented with Limb-Shaking TIA].
Uno, Junji; Mineta, Haruyuki; Ren, Nice; Takagishi, Sou; Nagaoka, Shintarou; Kameda, Katsuharu; Maeda, Kazushi; Ikai, Yoshiaki; Gi, Hidefuku
2016-07-01
Involuntary movement is a rare clinical manifestation of transient ischemic attack (TIA). However, limb-shaking TIA is well described presentation of carotid occlusive disease. We present the case of a patient who developed limb-shaking TIA associated with high-grade stenosis of middle cerebral artery (M1), which was treated with percutaneous transluminal angioplasty (PTA). The procedure was performed successfully without complication and the symptom disappeared immediately after the procedure. The patient remained free of symptoms at the 38-month follow-up. There was no tendency of restenosis of M1. In this case, PTA was technically feasible and beneficial for limb-shaking TIA with M1 stenosis. Limb-shaking TIA can be a symptom of high-grade stenosis of M1.
Computer quantitation of coronary angiograms
NASA Technical Reports Server (NTRS)
Ledbetter, D. C.; Selzer, R. H.; Gordon, R. M.; Blankenhorn, D. H.; Sanmarco, M. E.
1978-01-01
A computer technique is being developed at the Jet Propulsion Laboratory to automate the measurement of coronary stenosis. A Vanguard 35mm film transport is optically coupled to a Spatial Data System vidicon/digitizer which in turn is controlled by a DEC PDP 11/55 computer. Programs have been developed to track the edges of the arterial shadow, to locate normal and atherosclerotic vessel sections and to measure percent stenosis. Multiple frame analysis techniques are being investigated that involve on the one hand, averaging stenosis measurements from adjacent frames, and on the other hand, averaging adjacent frame images directly and then measuring stenosis from the averaged image. For the latter case, geometric transformations are used to force registration of vessel images whose spatial orientation changes.
Wong, Dennis T L; Narayan, Om; Leong, Darryl P; Bertaso, Angela G; Maia, Murilo G; Ko, Brian S H; Baillie, Timothy; Seneviratne, Sujith K; Worthley, Matthew I; Meredith, Ian T; Cameron, James D
2015-06-01
Aortic distensibility (AD) decreases with age and increased aortic stiffness is independently associated with adverse cardiovascular outcomes. The association of severe aortic stenosis (AS) with AD in different aortic regions has not been evaluated. Elderly subjects with severe AS and a cohort of patients without AS of similar age were studied. Proximal aortic cross-sectional-area changes during the cardiac cycle were determined using retrospective-ECG-gating on 128-detector row computed-tomography. Using oscillometric-brachial-blood-pressure measurements, the AD at the ascending-aorta (AA), proximal-descending-aorta (PDA) and distal-descending-aorta (DDA) was determined. Linear mixed effects modelling was used to determine the association of age and aortic stenosis on regional AD. 102 patients were evaluated: 36 AS patients (70-85 years), 24 AS patients (>85 years) and 42 patients without AS (9 patients <50 years, 20 patients between 51-70 years and 13 patients 70-85 years). When comparing patients 70-85 years, AA distensibility was significantly lower in those with AS compared to those without AS (0.9 ± 0.9 vs. 1.4 ± 1.1, P = 0.03) while there was no difference in the PDA (1.0 ± 1.1 vs. 1.0 ± 1.2, P = 0.26) and DDA (1.1 ± 1.2 vs. 1.2 ± 0.8, P = 0.97). In patients without AS, AD decreased with age in all aortic regions (P < 0.001). The AA in patients <50 years were the most distensible compared to other aortic regions. There is regional variation in aortic distensibility with aging. Patients with aortic stenosis demonstrated regional differences in aortic distensibility with lower distensibility demonstrated in the proximal ascending aorta compared to an age-matched cohort.
Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.
Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe
2017-07-01
After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.
Long-term hydrocephalus alters the cytoarchitecture of the adult subventricular zone
Campos-Ordoñez, Tania; Herranz-Pérez, Vicente; Chaichana, Kaisorn L.; Rincon-Torroella, Jordina; Rigamonti, Daniele; García-Verdugo, Jose M.; Quiñones-Hinojosa, Alfredo; Gonzalez-Perez, Oscar
2014-01-01
Hydrocephalus can develop secondarily to a disturbance in production, flow and/or absorption of cerebrospinal fluid. Experimental models of hydrocephalus, especially subacute and chronic hydrocephalus, are few and limited, and the effects of hydrocephalus on the subventricular zone are unclear. The aim of this study was to analyze the effects of long-term obstructive hydrocephalus on the subventricular zone, which is the neurogenic niche lining the lateral ventricles. We developed a new method to induce hydrocephalus by obstructing the aqueduct of Sylvius in the mouse brain, thus simulating aqueductal stenosis in humans. In 120-day-old rodents (n = 18 per group), the degree of ventricular dilatation and cellular composition of the subventricular zone were studied by immunofluorescence and transmission electron microscopy. In adult patients (age > 18 years), the sizes of the subventricular zone, corpus callosum, and internal capsule were analyzed by magnetic resonance images obtained from patients with and without aqueductal stenosis (n=25 per group). Mice with 60-day hydrocephalus had a reduced number of Ki67+ and doublecortin+ cells on immunofluorescence, as well as decreased number of neural progenitors and neuroblasts in the subventricular zone on electron microscopy analysis as compared to non-hydrocephalic mice. Remarkably, a number of extracellular matrix structures (fractones) contacting the ventricular lumen and blood vessels were also observed around the subventricular zone in mice with hydrocephalus. In humans, the widths of the subventricular zone, corpus callosum, and internal capsule in patients with aqueductal stenosis were significantly smaller than age and gender-matched patients without aqueductal stenosis. In summary, supratentorial hydrocephalus reduces the proliferation rate of neural progenitors and modifies the cytoarchitecture and extracellular matrix compounds of the subventricular zone. In humans, this similar process reduces the subventricular niche as well as the width of corpus callosum and internal capsule. PMID:24858805
Serrano, Carolina; Lostalé, Fernando; Rodríguez-Panadero, Francisco; Blas, Ignacio de; Laborda, Alicia; de Gregorio, Miguel Angel
2016-03-01
The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; P<.05), and higher granuloma formation on CT (50% of cases). The NiTi group showed the lowest grade of stenosis (2.86±6.91% vs. 11.28±13.98 and 15.54±25.95% in DES and ST, respectively; P<.05). The AP study revealed that the ST group developed intense proliferative reactivity compared to the other groups. In the DES group, a destructive response was observed in 70% of the animals, while the NiTi was the least reactive stent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; P<.001) than granuloma (not significant). The ST group developed granulomas and significant stenosis. NiTi was the least reactive stent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stampfl, Ulrike; Sommer, Christof-Matthias; Thierjung, Heidi
2008-11-15
The purpose of this study was to investigate the potential of nanoscale coating with the highly biocompatible polymer Polyzene-F (PZF), in combination with cobalt chromium and stainless steel stents, to reduce in-stent stenosis, thrombogenicity, and vessel wall injury and inflammation. One bare cobalt chromium, PZF-nanocoated stainless steel or PZF-nanocoated cobalt chromium stent was implanted in right coronary artery of 30 mini-pigs (4- or 12-week follow-up). Primary study end points were in-stent stenosis and thrombogenicity. Secondary study end points were vessel wall injury and inflammation as evaluated by microscopy and a new immunoreactivity score applying C-reactive protein (CRP), tumor-necrosis factor alphamore » (TNF{alpha}), and TGF{beta}. At 12 weeks, angiography showed a significantly lower average loss in lumen diameter (2.1% {+-} 3.05%) in PZF-nanocoated cobalt chromium stents compared with stents in the other groups (9.73% {+-} 4.93% for bare cobalt chromium stents and 9.71% {+-} 7% for PZF-nanocoated stainless steel stents; p = 0.04), which was confirmed at microscopy (neointima 40.7 {+-} 16 {mu}m in PZF-nanocoated cobalt chromium stents, 74.7 {+-} 57.6 {mu}m in bare cobalt chromium stents, and 141.5 {+-} 109 {mu}m in PZF-nanocoated stainless steel stents; p = 0.04). Injury and inflammation scores were low in all stents and were without significant differences. PZF-nanocoated cobalt chromium stents provided the highest efficacy in reducing in-stent stenosis at long-term follow-up. The PZF nanocoat proved to be biocompatible with respect to thromboresistance and inflammation. Our data suggest that its combination with cobalt chromium stents might provide an interesting passive stent platform.« less
Hickey, Edward J; McCrindle, Brian W; Blackstone, Eugene H; Yeh, Thomas; Pigula, Frank; Clarke, David; Tchervenkov, Christo I; Hawkins, John
2008-05-01
Limited availability and durability of allograft conduits require that alternatives be considered. We compared bovine jugular venous valved (JVV) and allograft conduit performance in 107 infants who survived truncus arteriosus repair. Children were prospectively recruited between 2003 and 2007 from 17 institutions. The median z-score for JVV (n=27, all 12 mm) was +2.1 (range +1.2 to +3.2) and allograft (n=80, 9-15mm) was +1.7 (range -0.4 to +3.6). Propensity-adjusted comparison of conduit survival was undertaken using parametric risk-hazard analysis and competing risks techniques. All available echocardiograms (n=745) were used to model deterioration of conduit function in regression equations adjusted for repeated measures. Overall conduit survival was 64+/-9% at 3 years. Conduit replacement was for conduit stenosis (n=16) and/or pulmonary artery stenosis (n=18) or regurgitation (n=1). The propensity-adjusted 3-year freedom from replacement for in-conduit stenosis was 96+/-4% for JVV and 69+/-8% for allograft (p=0.05). The risk of intervention or replacement for branch pulmonary artery stenosis was similar for JVV and allograft. Smaller conduit z-score predicted poor conduit performance (p<0.01) with best outcome between +1 and +3. Although JVV conduits were a uniform diameter, their z-score more consistently matched this ideal. JVV exhibited a non-significant trend towards slower progression of conduit regurgitation and peak right ventricular outflow tract (RVOT) gradient. In addition, catheter intervention was more successful at slowing subsequent gradient progression in children with JVV versus those with allograft (p<0.01). JVV does match allograft performance and may be advantageous. It is an appropriate first choice for repair of truncus arteriosus, and perhaps other small infants requiring RVOT reconstruction.
Kim, Kye-Hwan; Jeon, Kyung Nyeo; Kang, Min Gyu; Ahn, Jong Hwa; Koh, Jin-Sin; Park, Yongwhi; Hwang, Seok-Jae; Jeong, Young-Hoon; Kwak, Choong Hwan; Hwang, Jin-Yong; Park, Jeong Rang
2016-01-01
Background/Aims: This study is a head-to-head comparison of predictive values for long-term cardiovascular outcomes between exercise electrocardiography (ex-ECG) and computed tomography coronary angiography (CTCA) in patients with chest pain. Methods: Four hundred and forty-two patients (mean age, 56.1 years; men, 61.3%) who underwent both ex-ECG and CTCA for evaluation of chest pain were included. For ex-ECG parameters, the patients were classified according to negative or positive results, and Duke treadmill score (DTS). Coronary artery calcium score (CACS), presence of plaque, and coronary artery stenosis were evaluated as CTCA parameters. Cardiovascular events for prognostic evaluation were defined as unstable angina, acute myocardial infarction, revascularization, heart failure, and cardiac death. Results: The mean follow-up duration was 2.8 ± 1.1 years. Fifteen patients experienced cardiovascular events. Based on pretest probability, the low- and intermediate-risks of coronary artery disease were 94.6%. Odds ratio of CACS > 40, presence of plaque, coronary stenosis ≥ 50% and DTS ≤ 4 were significant (3.79, p = 0.012; 9.54, p = 0.030; 6.99, p < 0.001; and 4.58, p = 0.008, respectively). In the Cox regression model, coronary stenosis ≥ 50% (hazard ratio, 7.426; 95% confidence interval, 2.685 to 20.525) was only significant. After adding DTS ≤ 4 to coronary stenosis ≥ 50%, the integrated discrimination improvement and net reclassification improvement analyses did not show significant. Conclusions: CTCA was better than ex-ECG in terms of predicting long-term outcomes in low- to intermediate-risk populations. The predictive value of the combination of CTCA and ex-ECG was not superior to that of CTCA alone. PMID:27017387
Zhong, Chunyan; Guo, Yanli; Huang, Haiyun; Tan, Liwen; Wu, Yi; Wang, Wenting
2013-01-01
Objectives. To establish 3D models of coronary arteries (CA) and study their application in localization of CA segments identified by Transthoracic Echocardiography (TTE). Methods. Sectional images of the heart collected from the first CVH dataset and contrast CT data were used to establish 3D models of the CA. Virtual dissection was performed on the 3D models to simulate the conventional sections of TTE. Then, we used 2D ultrasound, speckle tracking imaging (STI), and 2D ultrasound plus 3D CA models to diagnose 170 patients and compare the results to coronary angiography (CAG). Results. 3D models of CA distinctly displayed both 3D structure and 2D sections of CA. This simulated TTE imaging in any plane and showed the CA segments that corresponded to 17 myocardial segments identified by TTE. The localization accuracy showed a significant difference between 2D ultrasound and 2D ultrasound plus 3D CA model in the severe stenosis group (P < 0.05) and in the mild-to-moderate stenosis group (P < 0.05). Conclusions. These innovative modeling techniques help clinicians identify the CA segments that correspond to myocardial segments typically shown in TTE sectional images, thereby increasing the accuracy of the TTE-based diagnosis of CHD. PMID:24348745
Fritz, Julie M.; Lurie, Jon D.; Zhao, Wenyan; Whitman, Julie M.; Delitto, Anthony; Brennan, Gerard P.; Weinstein, James N.
2013-01-01
Background/Context A period of non-surgical management is advocated prior to surgical treatment for most patients with lumbar spinal stenosis. Currently, little evidence is available to define optimal non-surgical management. Physical therapy is often used, however its use and effectiveness relative to other non-surgical strategies has not been adequately explored. Purpose Describe the utilization of physical therapy and other non-surgical interventions by patients with lumbar spinal stenosis and examine the relationship between physical therapy and long-term prognosis. Study Design Secondary analysis of the Spine Patient Outcomes Research Trial (SPORT) combining data from randomized and observational studies. Setting 13 spine clinics in 11 states in the United States. Patient Sample Patients with lumbar spinal stenosis receiving non-surgical management including those who did or did not receive physical therapy within 6 weeks of enrollment. Outcome Measures Primary outcome measures included cross-over to surgery, the bodily pain and physical function scales changes from the Survey Short Form 36 (SF-36), and the modified Oswestry Disability Index. Secondary outcome measures were patient satisfaction and the Sciatica Bothersomeness Index. Methods Baseline characteristics and rates of cross-over to surgery were compared between patients who did or did not receive physical therapy. Baseline factors predictive of receiving physical therapy were examined with logistic regression. Mixed effects models were used to compare outcomes between groups at 3 and 6 months, and 1 year after enrollment adjusted for baseline severity and patient characteristics. Results Physical therapy was used in the first 6 weeks by 90 of 244 patients (37%) and was predicted by the absence of radiating pain and being single instead of married. Physical therapy was associated with a reduced likelihood of cross-over to surgery after 1 year (21% vs 33%, p=0.045), and greater reductions on the SF-36 physical functioning scale after 6 months (mean difference =6.0, 95% CI: 0.2, 11.7) and 1 year (mean difference =6.5, 95% CI: 0.6, 12.4). There were no differences in bodily pain or Oswestry scores across time. Conclusion Many patients with lumbar spinal stenosis pursuing conservative management receive physical therapy. Using physical therapy was associated with reduced likelihood of patients receiving surgery within 1 year. Results for other outcomes were mixed with no differences in several measures. Further research is needed to examine the effectiveness of physical therapy relative to other non-surgical management strategies for patients with lumbar spinal stenosis. PMID:24373681
Cost-effectiveness of screening for asymptomatic carotid atherosclerotic disease.
Derdeyn, C P; Powers, W J
1996-11-01
The value of screening for asymptomatic carotid stenosis has become an important issue with the recently reported beneficial effect of endarterectomy. The purpose of this study is to evaluate the cost-effectiveness of using Doppler ultrasound as a screening tool to select subjects for arteriography and subsequent surgery. A computer model was developed to simulate the cost-effectiveness of screening a cohort of 1000 men during a 20-year period. The primary outcome measure was incremental present-value dollar expenditures for screening and treatment per incremental present-value quality-adjusted life-year (QALY) saved. Estimates of disease prevalence and arteriographic and surgical complication rates were obtained from the literature. Probabilities of stroke and death with surgical and medical treatment were obtained from published clinical trials. Doppler ultrasound sensitivity and specificity were obtained through review of local experience. Estimates of costs were obtained from local Medicare reimbursement data. A one-time screening program of a population with a high prevalence (20%) of > or = 60% stenosis cost $35130 per incremental QALY gained. Decreased surgical benefit or increased annual discount rate was detrimental, resulting in lost QALYs. Annual screening cost $457773 per incremental QALY gained. In a low-prevalence (4%) population, one-time screening cost $52588 per QALY gained, while annual screening was detrimental. The cost-effectiveness of a one-time screening program for an asymptomatic population with a high prevalence of carotid stenosis may be cost-effective. Annual screening is detrimental. The most sensitive variables in this simulation model were long-term stroke risk reduction after surgery and annual discount rate for accumulated costs and QALYs.
Iravani, Kamyar; Sobhanmanesh, Arash; Ashraf, Mohammad Javad; Hashemi, Seyed Basir; Mehrabani, Davood; Zare, Shahrokh
2017-05-01
Differences in causes, severities, areas of stenosis, and the association with swallowing and phonation of larynx and trachea can result into Laryngotracheal stenosis (LTS).This study evaluated the healing effect of bone marrow stem cells (BMSCs) in experimentally induced LTS dog model. Seven dogs were enrolled. BMSCs were isolated from proximal humerus and shoulder of a dog and cultured in media containing alpha minimal essential medium, fetal bovine serum, penicillin and streptomycin, and L-glutamine. BMSCs were characterized morphologically, by RT-PCR, and osteogenic induction. Karyotyping was undertaken for chromosomal stability. Mechanical trauma to laryngeal mucosa was identically conducted by Tru-cut punch forceps in right and left vocal folds. Two milliliter of conditioned media or BMSCs (2×10 6 ) were injected in the right site of the tissue and the left side was considered as control after LTS induction. The larynx was visualized 2, 4 and 6 weeks after treatment. Six weeks post-treatment, the larynges were evaluated histologically. BMSCs were adhered to culture flasks, spindle shape and positive for mesenchymal marker and negative for hematopoietic markers. Osteogenic induction was verified by Alizarin red staining. Karyotype was normal. A complete epithelialization and minimal chronic inflammatory cell infiltration were noted in submucosa of both left (control) and right (cases) vocal folds. The healing effect of conditioned media and BMSCs in comparison to the control group was more prominent. As thickness of fibrosis in cases were less than control group, conditioned media and BMSCs were shown to be good choices in healing of LTS.
The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...
Model Uncertainty Quantification Methods In Data Assimilation
NASA Astrophysics Data System (ADS)
Pathiraja, S. D.; Marshall, L. A.; Sharma, A.; Moradkhani, H.
2017-12-01
Data Assimilation involves utilising observations to improve model predictions in a seamless and statistically optimal fashion. Its applications are wide-ranging; from improving weather forecasts to tracking targets such as in the Apollo 11 mission. The use of Data Assimilation methods in high dimensional complex geophysical systems is an active area of research, where there exists many opportunities to enhance existing methodologies. One of the central challenges is in model uncertainty quantification; the outcome of any Data Assimilation study is strongly dependent on the uncertainties assigned to both observations and models. I focus on developing improved model uncertainty quantification methods that are applicable to challenging real world scenarios. These include developing methods for cases where the system states are only partially observed, where there is little prior knowledge of the model errors, and where the model error statistics are likely to be highly non-Gaussian.