Endoscopically placed nitinol stents for pediatric tracheal obstruction.
Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M
2002-11-11
To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland Ltd.
Fast Virtual Stenting with Active Contour Models in Intracranical Aneurysm
Zhong, Jingru; Long, Yunling; Yan, Huagang; Meng, Qianqian; Zhao, Jing; Zhang, Ying; Yang, Xinjian; Li, Haiyun
2016-01-01
Intracranial stents are becoming increasingly a useful option in the treatment of intracranial aneurysms (IAs). Image simulation of the releasing stent configuration together with computational fluid dynamics (CFD) simulation prior to intervention will help surgeons optimize intervention scheme. This paper proposed a fast virtual stenting of IAs based on active contour model (ACM) which was able to virtually release stents within any patient-specific shaped vessel and aneurysm models built on real medical image data. In this method, an initial stent mesh was generated along the centerline of the parent artery without the need for registration between the stent contour and the vessel. Additionally, the diameter of the initial stent volumetric mesh was set to the maximum inscribed sphere diameter of the parent artery to improve the stenting accuracy and save computational cost. At last, a novel criterion for terminating virtual stent expanding that was based on the collision detection of the axis aligned bounding boxes was applied, making the stent expansion free of edge effect. The experiment results of the virtual stenting and the corresponding CFD simulations exhibited the efficacy and accuracy of the ACM based method, which are valuable to intervention scheme selection and therapy plan confirmation. PMID:26876026
Antón-Pacheco, Juan L; Luna, Carmen; García, Enrique; López, María; Morante, Rocío; Tordable, Cristina; Palacios, Alba; de Miguel, Mónica; Benavent, Isabel; Gómez, Andrés
2016-06-01
To report our experience with a new type of biodegradable airway stent in the setting of severe tracheobronchial obstruction in children. We conducted a retrospective and prospective (since June 2014) study of pediatric patients with severe airway obstruction treated with biodegradable stents in our institution between 2012 and 2015. The following data were collected: demographics, indication for stenting, bronchoscopic findings, insertion technique complications, clinical outcome, stent related complications, re-stenting, and time of follow-up. Thirteen custom-made polydioxanone stents were placed in four infants (mean age, 4 months) with severe tracheobronchial obstruction: tracheomalacia (two patients), bronchomalacia (1), and diffuse tracheal stenosis (1). All the stents were bronchoscopically inserted uneventfully. Immediate and maintained clinical improvement was observed in every case. No major stent related complications have occurred and only mild or moderate granulation tissue was observed during surveillance bronchoscopy. Two patients required repeated stenting as expected. All the patients are alive and in a good respiratory condition with a follow-up ranging from 5 to 40 months. Biodegradable airway stents seem to be safe, effective, and cause fewer complications than other types of stents. They can be an alternative to the classic metallic or plastic stents for severe tracheal stenosis or malacia in small children. More experience is needed in order to establish the definite clinical criteria for their use in pediatric patients. Pediatr Pulmonol. 2016;51:607-612. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Matsuura, Hiroshi; Arase, Shigeki; Hori, Yasuhide; Tochigi, Hiromi
2017-12-01
In this study, we retrospectively reviewed the experiences at our single institute in the treatment of malignant extrinsic ureteral obstruction (MUO) using ureteral stents to investigate the clinical outcomes and the predictive factors of stent failure. In 52 ureters of 38 patients who had radiologically significant hydronephrosis due to MUO, internal ureteral stents (The BARD(R) INLAY(TM) ureteral stent set) were inserted. The median follow-up interval after the initial stent insertion was 124.5 days (4-1,120). Stent failure occurred in 8 ureters (15.4%) of the 7 patients. The median interval from the first stent insertion to stent failure was 88 days (1-468). A Cox regression multivariate analysis showed that the significant predictors of stent failure were bladder invasion. Based on the possibility of stent failure, the adaptation of the internal ureteral stent placement should be considered especially in a patient with MUO combined with bladder invasion.
Hamai, Yoichi; Hihara, Jun; Emi, Manabu; Okita, Riki; Shimizu, Katsuhiko; Okada, Morihito
2011-04-01
We herein describe a 41-year-old man with esophageal cancer who developed three esophagorespiratory fistulas (ERFs) that were successfully treated using one esophageal and three airway stents. A self-expandable metallic stent (SEMS) was initially inserted into the esophagus to close an ERF in the right bronchus. However, two new ERFs developed in the trachea and the left main bronchus 3 months later because of pressure necrosis and penetration of the esophageal SEMS. These secondary ERFs were subsequently closed using two silicone stents, together with one SEMS in the airway. This experience suggests that appropriate stenting can control multiple and large ERFs.
Polyflex expandable stents in the treatment of esophageal disease: initial experience.
Pennathur, Arjun; Chang, Andrew C; McGrath, Kevin M; Steiner, Gregory; Alvelo-Rivera, Miguel; Awais, Omar; Gooding, William E; Christie, Neil A; Gilbert, Sebastien; Landreneau, Rodney J; Luketich, James D
2008-06-01
The new generation of expandable plastic esophageal stents (Polyflex; Boston Scientific, Natick, MA), combine the features of plastic and self-expanding metallic stents. The main objective of this study is to evaluate our initial experience with Polyflex expandable stents in the treatment of esophageal disease from two institutions. A total of 58 Polyflex stents were placed in 38 patients over a two-year period. There were 24 men and 14 women, with a median age of 63 years (range, 25 to 83). The most common indication for placement was an esophageal stricture in 25 patients (66%); other causes included leak in 8 (21%) and tracheoesophageal fistula (TEF) in 5 (13%). We evaluated the hospital course, complications, and outcomes. The median postoperative stay was one day. Complications included migration in 38 stents (63%) (28 patients; 73%), retrosternal chest discomfort in nine, reflux in four, airway obstruction in one, and food impaction in three. Continued leak or a persistent TEF occurred in five patients (38%). Reintervention was required predominantly due to migration of the stent at a mean interval of 46 days (range, 1 to 353). Patients with dysphagia improved significantly with dysphagia scores (1 = no dysphagia; 5 = unable to swallow saliva) improving from 3.44 to 2.15 (p < 0.0001). Polyflex stents were effective in the relief of dysphagia due to strictures. They were less effective in esophageal perforations or leaks. Their primary disadvantage is a high migration rate and further improvements in design are required to decrease this high incidence of migration.
Siiki, Antti; Sand, Juhani; Laukkarinen, Johanna
2018-05-18
Biodegradable self-expanding stents are an emerging alternative to standard biliary stents as the development of endoscopic insertion devices advances. The aim was to systematically review the existing literature on biodegradable biliary stents. In-vivo studies on the use of biodegradable stents in the biliary duct were systematically reviewed from 1990 to 2017. Despite extensive research on the biocompatibility of stents, the experience so far on their clinical use is limited. A few favorable reports have recently been presented on endoscopically and percutaneously inserted self-expanding biodegradable polydioxanone stents in benign biliary strictures. Another potential indication appears to be postcholecystectomy leak of the cystic duct. The main benefit of biodegradable stents is that stent removal can be avoided. The biocompatibility of the current biodegradable stent materials, most prominently polydioxanone, is well documented. In the few studies currently available, biodegradable stents are reported to be feasible and safe, also in humans. The initial results of the endoscopic use of these stents in benign biliary stricture management and for treating postcholecystectomy bile leaks are promising. Further controlled studies on long-term clinical results and cost-effectiveness are needed.
Hallbergson, Anna; Esch, Jesse J; Tran, Trang X; Lock, James E; Marshall, Audrey C
2016-10-01
We have taken a novel approach using oral rapamycin - sirolimus - as a medical adjunct to percutaneous therapy in patients with in-stent stenosis and high risk of right ventricular failure. Peripheral pulmonary artery stenosis can result in right ventricular hypertension, dysfunction, and death. Percutaneous pulmonary artery angioplasty and stent placement acutely relieve obstructions, but patients frequently require re-interventions due to re-stenosis. In patients with tetralogy of Fallot or arteriopathy, the problem of in-stent stenosis contributes to the rapidly recurrent disease. Rapamycin was administered to 10 patients (1.5-18 years) with peripheral pulmonary stenosis and in-stent stenosis and either right ventricular hypertension, pulmonary blood flow maldistribution, or segmental pulmonary hypertension. Treatment was initiated around the time of catheterisation and continued for 1-3 months. Potential side-effects were monitored by clinical review and blood tests. Target serum rapamycin level (6-10 ng/ml) was accomplished in all patients; eight of the nine patients who returned for clinically indicated catheterisations demonstrated reduction in in-stent stenosis, and eight of the 10 patients experienced no significant side-effects. Among all, one patient developed diarrhoea requiring drug discontinuation, and one patient experienced gastrointestinal bleeding while on therapy that was likely due to an indwelling feeding tube and this patient tolerated rapamycin well following tube removal. Our initial clinical experience supports that patients with peripheral pulmonary artery stenosis can be safely treated with rapamycin. Systemic rapamycin may provide a novel medical approach to reduce in-stent stenosis.
NASA Astrophysics Data System (ADS)
Gallo, Annemarie; Mani, Gopinath
2013-08-01
Most drug-eluting stents currently available are coated with anti-proliferative drugs on both abluminal (toward blood vessel wall) and luminal (toward lumen) surfaces to prevent neointimal hyperplasia. While the abluminal delivery of anti-proliferative drugs is useful for controlling neointimal hyperplasia, the luminal delivery of such drugs impairs or prevents endothelialization which causes late stent thrombosis. This research is focused on developing a bidirectional dual drug-eluting stent to co-deliver an anti-proliferative agent (paclitaxel - PAT) and an endothelial cell promoting agent (nitric oxide - NO) from abluminal and luminal surfaces of the stent, respectively. Phosphonoacetic acid, a polymer-free drug delivery platform, was initially coated on the stents. Then, the PAT and NO donor drugs were co-coated on the abluminal and luminal stent surfaces, respectively. The co-coating of drugs was collectively confirmed by the surface characterization techniques such as Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), 3D optical surface profilometry, and contact angle goniometry. SEM showed that the integrity of the co-coating of drugs was maintained without delamination or cracks formation occurring during the stent expansion experiments. In vitro drug release studies showed that the PAT was released from the abluminal stent surfaces in a biphasic manner, which is an initial burst followed by a slow and sustained release. The NO was burst released from the luminal stent surfaces. Thus, this study demonstrated the co-delivery of PAT and NO from abluminal and luminal stent surfaces, respectively. The stent developed in this study has potential applications in inhibiting neointimal hyperplasia as well as encouraging luminal endothelialization to prevent late stent thrombosis.
Treatment of cerebral vasospasm with self-expandable retrievable stents: proof of concept.
Bhogal, Pervinder; Loh, Yince; Brouwer, Patrick; Andersson, Tommy; Söderman, Michael
2017-01-01
To report our preliminary experience with the use of stent retrievers to cause vasodilation in patients with delayed cerebral vasospasm secondary to subarachnoid hemorrhage. Four patients from two different high volume neurointerventional centers developed cerebral vasospasm following subarachnoid hemorrhage. In addition to standard techniques for the treatment of cerebral vasospasm, we used commercially available stent retrievers (Solitaire and Capture stent retrievers) to treat the vasospastic segment including M2, M1, A2, and A1. We evaluated the safety of this technique, degree of vasodilation, and longevity of the effect. Stent retrievers can be used to safely achieve cerebral vasodilation in the setting of delayed cerebral vasospasm. The effect is long-lasting (>24 hours) and, in our initial experience, carries a low morbidity. We have not experienced any complications using this technique although we have noted that the radial force was not sufficient to cause vasodilation in some instances. The vasospasm did not return in the vessel segments treated with stent angioplasty in any of these cases. In two of our cases stent angioplasty resulted in the reversal of focal neurological symptoms. Stent retrievers can provide long-lasting cerebral vasodilation in patients with delayed cerebral vasospasm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mermuys, Koen; Maleux, Geert, E-mail: geert.maleux@uzleuven.be; Heye, Sam
2008-07-15
Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent untilmore » the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.« less
Parenti, Dennis Zavalloni; Marsico, Federica; Tosi, Giovanni; Catalano, Gianpiero; Maiello, Luigi; Milone, Francesco; Carcagnì, Addolorata; Pron, Paolo Giay; Orecchia, Roberto; Presbitero, Patrizia
2003-03-01
Intracoronary brachytherapy has significantly reduced the recurrence of in-stent restenosis. The aim of this study was to evaluate the feasibility, safety and efficacy of intracoronary beta-radiation in patients at very high risk for recurrence of in-stent restenosis. We analyzed 42 patients with 50 lesions submitted to catheter-based beta-radiation (Beta-Cath System, Novoste Corporation, Norcross, GA, USA) for in-stent restenosis. Thirty-eight lesions were at the second restenosis, 8 at the third, and 4 at the fourth; a diffuse pattern was present in 78%. Balloon angioplasty was performed for 30 lesions (60%) and the cutting balloon technique for 20 (40%). In 12 lesions further 14 stents had to be deployed (28%). The delivery catheter was successfully positioned in 96% of the procedures. The mean dwell time was 179 +/- 50 s with a radiation dose ranging from 18.4 to 25.3 Gy, depending on the vessel size. A complete angiographic success without coronary dissection and without any additional stenting after radiation delivery was achieved in 86%. At follow-up (7.2 +/- 2.1 months), the overall restenosis rate was 30.4% (14 lesions). A recurrence was detected in 1/11 lesions with initial focal pattern and in 13/39 lesions with initial diffuse pattern. The restenosis rate was higher in patients in whom a geographic miss had occurred (p < 0.05 vs lesions without geographic miss) and in those in whom a new stent had been deployed (p < 0.05 vs lesions treated without a stent). Brachytherapy reduces the in-stent restenosis rate in patients who are at very high risk of recurrence. The restenosis pattern, geographic miss and new stent deployment seem to be negative prognostic factors for recurrence of restenosis.
Su, Wei; Zhang, Yisen; Chen, Junfan; Liu, Jian; Rajah, Gary; Yang, Xinjian
2018-04-23
Background For the treatment of intracranial aneurysms, the low-profile visualized intraluminal support (LVIS) stent is a new generation of highly visible-braided stent that was recently introduced in China. Here, we report our single-center retrospective experience of safety and efficacy utilizing LVIS for stent-assisted coiling of intracranial aneurysms. Methods We included 218 patients with intracranial aneurysms consecutively treated with LVIS SR stents at our center in this study. Postoperative and follow-up embolization scores, procedural complications, clinical and angiographic findings at mid-term follow-up, as well as recurrence rate, preoperative and follow-up mRS scores were analyzed. Results Two hundred and eighteen patients with two hundred and twenty five intracranial aneurysms were enrolled. The locations and distribution were ICA (125, 55.6%), PcomA (47, 20.9%), VA (38, 16.8%), and BA (15, 6.7%). Two hundred and eighteen aneurysms were treated with the stent-assisted coiling and seven patients with LVIS stents alone. Angiographic follow-up was available for 115 (51.1%) aneurysms, 8 (7.0%) of which had recurrences including 7 (6.5%) unruptured aneurysms and 1(14.3%) ruptured aneurysm. The procedural complication rate was 2.75% in total, including distal hemorrhage (1, 0.45%; SAH), ischemic events (5, 2.3%). Conclusions Our single-center retrospective experience is one of the larger studies to date assessing the LVIS device. Compared with many laser-cut stent studies, the LVIS device had a higher aneurysm complete occlusion rate at follow-up coupled with low complication rates. However, this study was our initial experience with LVIS, larger patient numbers, and longer follow-up will be needed to fully assess the long-term efficacy of LVIS in treating intracranial aneurysms.
The use of expandable metallic airway stents for tracheobronchial obstruction in children.
Filler, R M; Forte, V; Fraga, J C; Matute, J
1995-07-01
Expandable metallic angioplasty stents (Palmaz stent) have been implanted in the trachea and/or bronchi of seven children. Three children had severe tracheal stenosis after tracheoplasty for congenital tracheal stenosis repair, and four had tracheomalacia or bronchomalacia with or without vascular compression. The mean age at stenting was 9.7 months (range, 2 to 15 months). Balloon expandable stents were inserted into the trachea or bronchus through a 3.5-mm bronchoscope under fluoroscopic control. Initially a single tracheal stent was used for all patients except for one with obstruction in the trachea and both bronchi, in whom three stents were implanted. Three children had recurrent airway obstruction 1 month later; one was cured with a second stent; one child died 1 year later; and the other is being treated for heart disease. The others have no serious respiratory problems. The stents in all have been in place for 1 to 25 (mean, 11) months. No immediate complications were noted. Early and late bronchoscopy showed incomplete epithelialization of the stent and patches of granulation tissue on it. Two stents were removed bronchoscopically, one at the completion of treatment for tracheomalacia and the other at the time of recurrent airway obstruction. This preliminary experience indicates that expandable metallic stents have a useful role in the treatment of selected lower airway obstructions.
Erickson, Bradley A.; McAninch, Jack W.; Eisenberg, Michael L.; Washington, Samuel L.; Breyer, Benjamin N.
2013-01-01
Purpose Prostate cancer treatment has the potential to lead to posterior urethral stricture. These strictures are sometimes recalcitrant to dilation and urethrotomy alone. We present our experience with the Urolume® stent for prostate cancer treatment related stricture. Materials and Methods A total of 38 men with posterior urethral stricture secondary to prostate cancer treatment were treated with Urolume stenting. Stents were placed in all men after aggressive urethrotomy over the entire stricture. A successfully managed stricture was defined as open and stable for greater than 6 months after any necessary secondary procedures. Results The initial success rate was 47%. After a total of 31 secondary procedures in 19 men, including additional stent placement in 8 (18%), the final success rate was 89% at a mean ± SD followup of 2.3 ± 2.5 years. Four cases (11%) in which treatment failed ultimately requiring urinary diversion (3) or salvage prostatectomy (1). Incontinence was noted in 30 men (82%), of whom 19 (63%) received an artificial urinary sphincter a mean of 7.2 ± 2.4 months after the stent. Subanalysis revealed that irradiated men had longer strictures (3.6 vs 2.0 cm, p = 0.003) and a higher post-stent incontinence rate (96% vs 50%, p <0.001) than men who underwent prostatectomy alone but the initial failure rate was similar (54% vs 50%, p = 0.4). Conclusions Urolume stenting is a reasonable option for severe post-prostate cancer treatment stricture when patients are unwilling or unable to undergo open reconstructive surgery. Incontinence should be expected. The need for additional procedures is common and in some men may be required periodically for the lifetime of the stent. PMID:21074796
O'Kelly, C J; Spears, J; Chow, M; Wong, J; Boulton, M; Weill, A; Willinsky, R A; Kelly, M; Marotta, T R
2013-02-01
Flow-diverting stents, such as the PED, have emerged as a novel means of treating complex intracranial aneurysms. This retrospective analysis of the initial Canadian experience provides insight into technical challenges, clinical and radiographic outcomes, and complication rates after the use of flow-diverting stents for unruptured aneurysms. Cases were compiled from 7 Canadian centers between July 2008 and December 2010. Each center prospectively tracked their initial experience; these data were retrospectively updated and pooled for analysis. During the defined study period, 97 cases of unruptured aneurysm were treated with the PED, with successful stent deployment in 94 cases. The overall complete or near-complete occlusion rate was 83%, with a median follow-up at 1.25 years (range 0.25-2.5 years). Progressive occlusion was witnessed over time, with complete or near-complete occlusion in 65% of aneurysms followed through 6 months, and 90% of aneurysms followed through 1 year. Multivariate analysis found previous aneurysm treatment and female sex predictive of persistent aneurysm filling. Most patients were stable or improved (88%), with the most favorable outcomes observed in patients with cavernous carotid aneurysms. The overall mortality rate was 6%. Postprocedural aneurysm hemorrhage occurred in 3 patients (3%), while ipsilateral distal territory hemorrhage was observed in 4 patients (3.4%). Flow-diverting stents represent an important tool in the treatment of complex intracranial aneurysms. The relative efficacy and morbidity of this treatment must be considered in the context of available alternate interventions.
Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth
2018-01-01
Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368
Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth
2018-03-01
Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim
2015-01-01
Abstract Introduction: Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. Materials and Methods: We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. Results: The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (p<0.001) and lengths (p=0.001) compared to Karl Storz and Ethicon trocars (29.41, 18.06, and 17.22 mm2, respectively, and 14.29, 11.39, and 12.15 mm, respectively). Conclusions: In this pilot study, 3D printing of ureteral stents and trocars is feasible, and these devices can be deployed in the porcine and cadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future. PMID:24983138
del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim; Landman, Jaime
2015-01-01
Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (p<0.001) and lengths (p=0.001) compared to Karl Storz and Ethicon trocars (29.41, 18.06, and 17.22 mm(2), respectively, and 14.29, 11.39, and 12.15 mm, respectively). In this pilot study, 3D printing of ureteral stents and trocars is feasible, and these devices can be deployed in the porcine and cadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future.
Natural stent in the management of post-intubation tracheal stenosis.
Park, Hye Yun; Kim, Hojoong; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung
2009-05-01
The treatment choice for post-intubation tracheal stenosis (PITS) in patients for whom surgery is not initially feasible is bronchoscopic silicone stenting. A new silicone stent, called the Natural stent (N stent), was investigated for its clinical efficacy and safety in patients with PITS. A retrospective review was conducted of 32 patients with PITS who underwent N stenting between November 2001 and December 2006 and were followed for at least 12 months. Airway dilatation with combined modalities such as Nd:YAG laser, ballooning or bougienage was followed by N stent insertion. After intervention, all patients had symptomatic and spirometric improvement without immediate complications. Removal of the stent without re-stenosis was successful in 38% of the patients at a median time of 7 months after insertion. The stent could not be removed or needed reinsertion in 31% of patients, and 16% of patients underwent surgery after initial stabilization by stenting. Late complications were stent migration (34%), mucostasis (31%), granulation tissue formation (38%) and re-stenosis (40%). All patients tolerated the management of complications during a median follow up of 22 months. Bronchoscopic N stenting is an effective treatment for patients with PITS in whom surgery is not feasible on initial presentation. Further stent development is necessary to reduce the late complication rate.
Nayar, Manu K; Oppong, Kofi W; Bekkali, Noor L H; Leeds, John S
2018-05-01
Radiofrequency ablation (RFA) is used to treat blocked biliary stents in patients with pancreaticobiliary (PB) tumors with varying results. We report our experience with a novel temperature-controlled probe for treatment of blocked metal stents. Patients with histologically proven PB cancers and a blocked biliary stents were treated using ELRATM electrode (Taewoong Medical) under fluoroscopic guidance. Demographics, clinical outcome, stricture diameter improvements, complications and mortality at 30 days were prospectively recorded. Nine procedures were performed on seven patients (4 male, 3 female); mean age 65.33 (range 56 - 82 years). Mean stricture diameter prior to RFA was 1.13 mm (SD ± 0.54) and 4.42 mm (SD ± 1.54) following RFA ( P < 0.0001). Five of seven patients (71 %) required additional stents to ensure optimal drainage. There were no procedure-related complications. Mean follow-up was 193.55 days (range 31 - 540) and three of nine patients (33 %) died due to terminal cancer. These are the first reported data on use of a temperature-controlled RFA catheter in humans to treat blocked metal biliary stents. The device is safe but further randomized trials are required to establish the efficacy and survival benefits of this probe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cerna, Marie; Koecher, Martin, E-mail: martin.kocher@seznam.cz; Valek, Vlastimil
2011-12-15
Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during amore » balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.« less
Chandran, Sujievvan; Efthymiou, Marios; Kaffes, Arthur; Chen, John Wei; Kwan, Vu; Murray, Michael; Williams, David; Nguyen, Nam Quoc; Tam, William; Welch, Christine; Chong, Andre; Gupta, Saurabh; Devereaux, Ben; Tagkalidis, Peter; Parker, Frank; Vaughan, Rhys
2015-01-01
Recent medical literature on novel lumen-apposing stents for the treatment of pancreatic fluid collections (PFCs) is limited by small numbers, solo operators, and single-center experience. To evaluate a recently developed lumen-apposing, fully covered self-expandable metal stent (FCSEMS) in the management of PFCs. Retrospective case series. Thirteen tertiary and private health care centers across Australia. Forty-seven patients (median age 51 years) who underwent endoscopic management of PFCs. Insertion of FCSEMS after PFC puncture under EUS guidance. A subgroup of 9 patients underwent direct endoscopic necrosectomy. Technical and clinical success rate, adverse event rate. The technical success rate was 53 of 54 patients (98.1%), and the initial clinical success rate was 36 of 47 (76.6%), which was sustained for more than 6 months in 34 of 36 (94.4%). Early adverse events included 4 cases (7.4%) of stent migration during direct endoscopic necrosectomy, 4 cases (7.4%) of sepsis, 1 case (1.9%) of bleeding, and 1 case (1.9%) of stent migration into the fistula tract. Late adverse events were 6 (11.1%) spontaneous stent migrations, 3 (5.6%) recurrent stent occlusions, 3 (5.6%) tissue ingrowth/overgrowth, and 2 (3.7%) bleeding into PFC. The majority of stents inserted (48 of 54, 88.9%) and removed (31 of 35, 88.6%) in our study were described by the operator as superior to pigtail stents with regard to ease of use. Retrospective study. Although FCSEMSs are technically easier to insert and remove compared with traditional pigtail stents, there are significant limitations to the widespread use of FCSEMSs in the management of PFCs. These include cost, adverse events, and lower-than-expected resolution rates. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Bilateral complete ureteral duplication with calculi obstructing both limbs of left double ureter.
Aiken, William D; Johnson, Peter B; Mayhew, Richard G
2015-01-01
A woman with bilateral complete ureteral duplication with stones simultaneously obstructing both limbs of the left double ureter is presented. A search of the English medical literature suggests that this is the first reported case. Based on the initial difficulty accessing the stones via ureteroscopy we make recommendations regarding how this rare problem should be approached if encountered. A 37-year old woman with left-sided flank pain was discovered on CT scan to have bilateral complete ureteral duplication and three stones obstructing both limbs of the left double ureter. Ureteroscopy was initially unsuccessful due to the very small calibre and unyielding nature of the ureters and both ureteral limbs were stented. Repeat ureteroscopy was easily achieved after pre-stenting and the impacted stones were completely cleared with intracorporeal laser lithotripsy. The smaller calibre of both double ureters and their presence in a common adventitial sheath distally, made initial attempts at ureteroscopy difficult. Stenting both limbs increased ureteral compliance, passively dilated both ureters and allowed for improved manoeuvrability and retrograde passage of the ureteroscope. Based on the experience with this first reported case it is recommended that pre-stenting should be routinely performed prior to any attempt at ureteroscopy in cases of stones complicating completely duplicated ureters. We report the first recorded case of bilateral complete ureteral duplication with stones simultaneously obstructing both limbs of the double ureter and recommend that routine pre-stenting be done prior to ureteroscopy to allow easy uncomplicated retrograde passage of the ureteroscope. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guntau, Moritz, E-mail: guntau@med.uni-marburg.de; Hegele, Axel; Rheinheimer, Stephan
PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications.more » Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endo, Masayuki, E-mail: masay010@yahoo.co.jp; Kaminou, Toshio, E-mail: kaminout@med.tottori-u.ac.jp; Ohuchi, Yasufumi, E-mail: oyasu@med.tottori-u.ac.jp
Purpose: Covered, self-expandable metallic stents (SEMS) have been enthusiastically adopted for the treatment of esophagotracheal fistula, but problems with stent migration have yet to be resolved. To overcome this problem, we have developed a new hanging-type esophageal stent designed to prevent migration, and we conducted an animal study to assess the efficacy of our method. Methods: A total of six female pigs were used in this study. The main characteristic of our stent was the presence of a string tied to the proximal edge of the stent for fixation under the skin of the neck. The first experiment was performedmore » to confirm technical feasibility in three pigs with esophagotracheal fistula. The second experiment was performed to evaluate stent migration and esophagotracheal fistula in three pigs. Results: Creation of the esophagotracheal fistula and stent placement were technically successful in all pigs. In the first experiment, esophagotracheal fistula was sealed by stent placement. In the second experiment, no stent migration was seen 11 or 12 days after stent placement. Gross findings showed no fistulas on the esophageal or tracheal wall. Conclusions: Our new hanging-type esophageal stent seems to offer a feasible method for preventing stent migration.« less
Jang, Sung Ill; Hwang, Jin-Hyeok; Lee, Kwang-Hun; Yu, Jeong-Sik; Kim, Hee Wook; Yoon, Chang Jin; Lee, Yoon Suk; Paik, Kyu Hyun; Lee, Sang Hyub; Lee, Dong Ki
2017-04-01
Palliative endoscopic or percutaneous biliary drainage is used for unresectable advanced hilar cancer (HC). The best option for drainage in Bismuth type III or IV HC has not been established. The aims of this study are to identify factors predictive of endoscopic stenting failure and evaluate the effectiveness of rescue percutaneous stenting in patients with advanced HC. Data from 110 patients with inoperable advanced HC were retrospectively reviewed. All received bilateral self-expandable metallic stents. Patients were divided into three groups: I, successful initial endoscopic stenting; II, unsuccessful initial endoscopic stenting, followed by percutaneous stenting; and III, initial percutaneous stenting. We analyzed clinical results and radiologic tumor characteristics. Baseline characteristics and clinical outcomes of all groups were similar, except the hospital stay was longer in group III than group I. Technical success rate was higher in groups II and III (100%) than in group I (72.4%). The functional success rate, stent patency time, patient survival time, and complication rate were similar between groups. Endoscopic stenting failed because of guide-wire passage failure (n = 12) or stent passage failure (n = 7). The only factor significantly associated with endoscopic failure was a smaller left intrahepatic duct-common bile duct angle. As clinical outcomes were generally similar between approaches, percutaneous stenting is recommended for patients with Bismuth type III or IV advanced HC. Acute left intrahepatic duct-common bile duct angulation predicts endoscopic stenting failure. If endoscopic stenting fails, immediate conversion to the percutaneous approach is a necessary and effective rescue method. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Kogure, Hirofumi; Isayama, Hiroyuki; Nakai, Yousuke; Tsujino, Takeshi; Matsubara, Saburo; Yashima, Yoko; Ito, Yukiko; Hamada, Tsuyoshi; Takahara, Naminatsu; Miyabayashi, Koji; Mizuno, Suguru; Mohri, Dai; Kawakubo, Kazumichi; Sasaki, Takashi; Yamamoto, Natsuyo; Hirano, Kenji; Sasahira, Naoki; Tada, Minoru; Koike, Kazuhiko
2014-01-01
Endoscopic bilateral self-expandable metallic stent (SEMS) placement in a stent-in-stent method for malignant hilar biliary obstruction is technically challenging. Technical difficulties in the initial placement and reinterventions for stent occlusion are disadvantages inherent to this stent-in-stent method. We previously reported the feasibility of Niti-S large cell D-type biliary stents (LCD). This multicenter prospective consecutive study evaluated the efficacy of bilateral SEMS placement using modified LCD with large and uniform cells, a slimmer delivery system and high radial force. From July 2010 to June 2011, 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent endoscopic bilateral placement of modified LCD in a stent-in-stent method at three tertiary hospitals. Ten patients had gallbladder cancer, eight had cholangiocarcinoma, four had lymph node metastasis, two had intrahepatic cholangiocarcinoma, and two had liver metastasis. Single-session and final technical success rate was 96% and 100%, respectively. Functional success rate was 89%. Stent occlusion occurred in 11 patients (42%) because of sludge (n = 7) or tumor ingrowth (n = 4). Endoscopic bilateral reintervention was technically easy and successful: six patients had stent clearance by balloon sweeping and five had plastic stent placement. According to Kaplan-Meier analysis, median survival and stent patency were 220 days and 157 days, respectively. Modified LCD achieved a high technical success rate both in the initial stent-in-stent placement and in bilateral reinterventions in patients with malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Barkun, Alan N; Adam, Viviane; Martel, Myriam; AlNaamani, Khalid; Moses, Peter L
2015-01-01
BACKGROUND/OBJECTIVE: Partially covered self-expandable metal stents (SEMS) and polyethylene stents (PES) are both commonly used in the palliation of malignant biliary obstruction. Although SEMS are significantly more expensive, they are more efficacious than PES. Accordingly, a cost-effectiveness analysis was performed. METHODS: A cost-effectiveness analysis compared the approach of initial placement of PES versus SEMS for the study population. Patients with malignant biliary obstruction underwent an endoscopic retrograde cholangiopancreatography to insert the initial stent. If the insertion failed, a percutaneous transhepatic cholangiogram was performed. If stent occlusion occurred, a PES was inserted at repeat endoscopic retrograde cholangiopancreatography, either in an outpatient setting or after admission to hospital if cholangitis was present. A third-party payer perspective was adopted. Effectiveness was expressed as the likelihood of no occlusion over the one-year adopted time horizon. Probabilities were based on a contemporary randomized clinical trial, and costs were issued from national references. Deterministic and probabilistic sensitivity analyses were performed. RESULTS: A PES-first strategy was both more expensive and less efficacious than an SEMS-first approach. The mean per-patient costs were US$6,701 for initial SEMS and US$20,671 for initial PES, which were associated with effectiveness probabilities of 65.6% and 13.9%, respectively. Sensitivity analyses confirmed the robustness of these results. CONCLUSION: At the time of initial endoscopic drainage for patients with malignant biliary obstruction undergoing palliative stenting, an initial SEMS insertion approach was both more effective and less costly than a PES-first strategy. PMID:26125107
Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.
Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto
2015-08-01
Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Dan, D T; Gannavarapu, B; Lee, J G; Chang, K; Muthusamy, V R
2014-08-01
With the recent availability of removable esophageal stents, endoscopic stenting has been utilized to treat refractory benign esophageal strictures (RBES). The objective of this study was to review the feasibility and effectiveness of removable esophageal stents to treat RBES. Patients who received removable esophageal stents for the treatment of RBES at the institution between 2004-2010 using its stent implantation logs and endoscopic database were retrospectively identified. Patient demographics, stricture etiology and location, stent and procedure characteristics, and clinical outcomes were obtained. Twenty-five patients with a mean age of 70 (72% male) underwent initial stent placement; 24 were successful. Overall clinical success was achieved in five of the 19 patients (26%) ultimately undergoing stent removal. RBES etiologies included anastomotic (13), radiation (5), peptic (3), chemotherapy (1), scleroderma (1), and unknown (2). Alimaxx-E (Merit-Endotek, South Jordan, UT, USA) stents were placed in 20 patients and Polyflex (Boston Scientific, Natick, MA, USA) stents were used in five patients. Immediate complications included failed deployment (1) and chest pain (7). Five patients died prior to stent removal. Stent migration was found in 53% (10/19) of patients who underwent stent removal: nine required additional therapy and one had symptom resolution. Out of the nine patients without stent migration, five required additional therapy and four had symptom resolution. Although placement of removable esophageal stents for RBES is technically feasible, it is frequently complicated by stent migration and chest pain. In addition, few patients achieved long-term stricture resolution after initial stenting. In this study, most patients ultimately required repeated stenting and/or dilations to maintain relief of dysphagia. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Time Sequence Evaluation of Biliary Stent Occlusion by Dissection Analysis of Retrieved Stents.
Kwon, Chang-Il; Gromski, Mark A; Sherman, Stuart; Easler, Jeffrey J; El Hajj, Ihab I; Watkins, James; Fogel, Evan L; McHenry, Lee; Lehman, Glen A
2016-08-01
Multiple factors can affect the occlusion of plastic stents. Previous data demonstrate that side holes may induce more biofilm formation probably via microturbulence and bile flow disturbances that could lead to occlusion. These results, however, have not been replicated in subsequent clinical studies with different methods. The objective of this study is to evaluate the physical characteristics of plastic stent occlusion over time. This is a plastic stent sequential analysis study. Biliary stents removed via ERCP from February 24, 2015, to June 2, 2015, were included. One hundred and forty-eight retrieved straight-type plastic stents were longitudinally cut by a custom-made cutting device. These dissected stents were then evaluated in detail with regard to the location of stent occlusion and the stent patency period. Location of stent occlusive debris was the primary outcome in this study. Biofilm formations and occlusions by debris were sequentially but separately tallied. Biofilm formations were initially seen around the side hole areas within 30 days and spread to the entire stent by 60 days. Then, occlusion process by debris was mainly initiated by 80 days and progressed to full occlusion by median of 90 days. Although some occlusions were also observed around the side hole areas within 30 days, affected areas were more widely observed after biofilm formation. This study is the first to attempt to describe the distribution of stent occlusions over time. These observations may help guide future stent development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Jehong; Kwon, Se Hwan, E-mail: Kwon98@khu.ac.kr; Lee, Chang-Kyun
PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructivemore » symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.« less
Upper Gastrointestinal Stent Insertion in Malignant and Benign Disorders
Kang, Hyoun Woo
2015-01-01
Upper gastrointestinal (GI) stents are increasingly being used to manage upper GI obstructions. Initially developed for palliative treatment of esophageal cancer, upper GI stents now play an emerging role in benign strictures of the upper GI tract. Because recurrent obstruction and stent-related complications are common, new modifications of stents have been implemented. Self-expandable metal stents (SEMS) have replaced older plastic stents. In addition, newly designed SEMS have been developed to prevent complications. This review provides an overview of the various types, indications, methods, complications, and clinical outcomes of upper GI stents in a number of malignant and benign disorders dividing the esophagus and gastroduodenum. PMID:26064817
Bernardini, Annarita; Larrabide, Ignacio; Morales, Hernán G.; Pennati, Giancarlo; Petrini, Lorenza; Cito, Salvatore; Frangi, Alejandro F.
2011-01-01
Cerebral aneurysms are abnormal focal dilatations of artery walls. The interest in virtual tools to help clinicians to value the effectiveness of different procedures for cerebral aneurysm treatment is constantly growing. This study is focused on the analysis of the influence of different stent deployment approaches on intra-aneurysmal haemodynamics using computational fluid dynamics (CFD). A self-expanding stent was deployed in an idealized aneurysmatic cerebral vessel in two initial positions. Different cases characterized by a progression of simplifications on stent modelling (geometry and material) and vessel material properties were set up, using finite element and fast virtual stenting methods. Then, CFD analysis was performed for untreated and stented vessels. Haemodynamic parameters were analysed qualitatively and quantitatively, comparing the cases and the two initial positions. All the cases predicted a reduction of average wall shear stress and average velocity of almost 50 per cent after stent deployment for both initial positions. Results highlighted that, although some differences in calculated parameters existed across the cases based on the modelling simplifications, all the approaches described the most important effects on intra-aneurysmal haemodynamics. Hence, simpler and faster modelling approaches could be included in clinical workflow and, despite the adopted simplifications, support clinicians in the treatment planning. PMID:22670204
Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K
2016-06-01
Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma.
Spiegel, Detlev; Wetzel, Wolfgang; Haffner, David S; Hill, Richard A
2007-01-01
This study was undertaken to evaluate the efficiency of a trabecular micro-bypass stent designed to allow direct aqueous drainage from the anterior chamber into Schlemm's canal in patients with glaucoma. In this prospective case series of 6 patients with open-angle glaucoma, the microstent was inserted ab interno under local anesthesia in an ophthalmic operating room. Patients were seen postoperatively at 1 to 2 d, 1 wk, and 1, 2, 6, and 12 mo. All stents were successfully placed within Schlemm's canal. Mean intraocular pressure (IOP) at preoperative baseline was 20.2+/-6.3 mm Hg (range, 14-31 mm Hg). Mean IOP decreased during the immediate postoperative period to approximately 12 to 13 mm Hg and was stabilized at 14 to 15 mm Hg with reduction of medication throughout 1 y of follow-up. No major complications occurred. According to observations reported in this feasibility study, the microstent was effective in reducing IOP and in decreasing the number of glaucoma medications required to control IOP. Implantation procedures were safe, and stents remained in place throughout the follow-up period. None of the complications traditionally associated with filtering surgery were reported. Further research on this stent in a larger group of patients is needed to assess its role in glaucoma therapy.
The Management of Superior Mesenteric Artery Aneurysm: Experience with 16 Cases in a Single Center.
Zilun, Li; Henghui, Yin; Yang, Zhao; Mian, Wang; Guangqi, Chang; Shenming, Wang
2017-07-01
Superior mesenteric artery aneurysm (SMAA) represents a rare but potentially fatal condition. This study aimed to present the individual management protocol of SMAA in our center and to discuss a potential preliminary treatment algorithm. SMAA patients treated in our center between January 2007 and December 2014 were retrospectively reviewed on January 2015. Sixteen patients with SMAA were identified, including 1 female and 15 males, with a mean age of 48.9 ± 12.9 years. Three patients (3/16, 18.8%) were treated by multiple overlapping bare stents and one (1/16, 6.3%) initially by a single bare stent. Two cases (2/16, 12.5%) were treated by a covered stent implantation, but one of those suffered from SMAA rupture 7 days later, whereas the other had inner-stent thrombosis one month after discharge and died from multiple organ-dysfunction syndrome. Nine patients (9/16, 56.2%) received conservative therapy, one of who received multiple overlapping bare stents implantations for persistent abdominal pain. One patient underwent open surgery. There were 2 major complications, with no death during hospitalization and 1 death during follow-up. SMAA treatment needs to be individually prescribed, based on clinical manifestation, anatomy, and etiology. Multiple overlapping bare stents are safe and effective in selective patients with SMAA, and covered stents should be used with caution to avoid covering proximal branches; open surgery should be reserved for patients with suspected intestinal necrosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Role of stenting in gastrointestinal benign and malignant diseases
Mangiavillano, Benedetto; Pagano, Nico; Arena, Monica; Miraglia, Stefania; Consolo, Pierluigi; Iabichino, Giuseppe; Virgilio, Clara; Luigiano, Carmelo
2015-01-01
Advances in stents design have led to a substantial increase in the use of stents for a variety of digestive diseases. Initially developed as a non-surgical treatment for palliation of esophageal cancer, the stents now have an emerging role in the management of malignant and benign conditions as well as in all segments of the gastrointestinal tract. In this review, relevant literature search and expert opinions have been used to evaluate the key-role of stenting in gastrointestinal benign and malignant diseases. PMID:25992186
Extracranial carotid angioplasty and stenting. Initial results and short-term follow-up.
Vozzi, C R; Rodriguez, A O; Paolantonio, D; Smith, J A; Wholey, M H
1997-01-01
Carotid percutaneous transluminal angioplasty, with or without stent implantation, is becoming another therapeutic option for carotid revascularization. To evaluate the feasibility and effectiveness of the technique, from October of 1995 to March of 1997, we performed 24 percutaneous transluminal angioplasty procedures in 22 patients with severe extracranial carotid artery stenosis. Three common carotid and 21 internal carotid arteries were treated, and 19 procedures included stent implantation using nonarticulated PALMAZ stents (P154 and P204). Twelve patients were asymptomatic and 10 patients were symptomatic; 2 of the symptomatic patients had complete obstruction of the internal carotid artery that was successfully recanalized. Technical and angiographic success was achieved in 23 of 24 procedures, with the carotid artery obstruction diminishing from 85.6% +/- 8.5% to 5.7% +/- 3.2% (P < 0.001). Average stenosis length was 12.5 +/- 3.1 mm, and mean time of carotid occlusion during balloon inflation was 11.5 +/- 2.5 seconds. Three patients experienced transitory seizures during the procedure prior to dilation, 1 patient had a minor stroke with complete recovery within 72 hours, and 1 patient had a major stroke and died 45 days after the procedure. Clinical follow-up was achieved in all patients (mean, 10.5 +/- 7.2 months) and angiographic follow-up in 16 patients (mean, 6.3 +/- 1.2 months). The results obtained in this initial experience provide adequate support to continue further evaluation of this new therapeutic strategy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozkan, Ugur, E-mail: radugur@yahoo.com; Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Tercan, Fahri, E-mail: ftercan@yahoo.com
The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques weremore » successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.« less
Walter, Daisy; Laleman, Wim; Jansen, Jeroen M; van Milligen de Wit, A W M; Weusten, Bas L; van Boeckel, Petra G; Hirdes, Meike M; Vleggaar, Frank P; Siersema, Peter D
2015-05-01
Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. To evaluate the efficacy of a novel FCSEMS with antimigration features. Prospective cohort study. Five hospitals in the Netherlands and Belgium. Consecutive patients with BBS. FCSEMS placement for 3 months. Initial and long term clinical success, stent migration rate and safety. Thirty-eight patients (24 men; mean age, 53 ± 16 years) were included. Stent placement was technically successful in 37 patients (97%). Two patients died of an unrelated cause before stent removal, and no data on these patients were available on stricture resolution. Initial clinical success was achieved in 28 of 35 patients (80%). During follow-up after stent removal, a symptomatic recurrent stricture developed in 6 of 28 patients (21%). Overall, the long-term clinical success rate was 63% (22 of 35 patients). Stent migration occurred in 11 of 35 patients (31%), including 5 symptomatic (14%) and 6 asymptomatic (17%) migrations. In total, 11 serious adverse events occurred in 10 patients (29%), with cholangitis (n = 5) being most common. Nonrandomized study design. Good initial clinical success was achieved after placement of this novel FCSEMS, but stricture recurrence was in the upper range compared with other FCSEMSs. The antimigration design could not prevent migration in a significant number of patients with a persisting stricture. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Longitudinal Deformation of Distal Edge in a New-Generation Stent Caused by Guidewire Entrapment
Taleb, Adam; Parikh, Gaurav
2018-01-01
Longitudinal stent deformation, described in some older stent geometries, prompted design modifications such as reinforcing struts on the proximal end. However, distal edges of stents—also subject to longitudinal force—have not been reinforced. We report a case of guidewire entrapment that deformed the distal edge of a new-generation stent during percutaneous coronary intervention, and we describe our efforts to restore the stent to its initial length. This case highlights the risk of manipulating equipment beyond the position of a newly deployed stent, the ongoing potential for deformation of distal edges in newer stent platforms, and the advisability of treating distal lesions before proximal ones. PMID:29556153
Delayed relapse in pseudotumor cerebri due to new stenosis after transverse sinus stenting
Winters, Hugh Stephen; Parker, Geoff; Halmagyi, Gabor Michael; Mehta, Ankur; Atkins, Thomas
2015-01-01
A patient presented with recurrent severe pseudotumor cerebri (PTC). Transverse sinus stenting is a very effective treatment option, however stenosis and intracranial hypertension can recur. In our patient, stenting initially resulted in resolution of papilloedema. However, after 5 years, a new stenosis developed which required further stenting. This case highlights the fact that, in patients with PTC who undergo transverse sinus stenting, a small proportion require repeat treatment due to formation of a new stenosis, usually adjacent to the existing stent. Patients with severe disease, such as ours, may be at higher risk of recurrence. Regardless of the severity, all patients who undergo stenting should have regular ocular follow-up. PMID:26351311
Finet, Gérard; Derimay, François; Motreff, Pascal; Guerin, Patrice; Pilet, Paul; Ohayon, Jacques; Darremont, Olivier; Rioufol, Gilles
2015-08-24
This study used a fractal bifurcation bench model to compare 6 optimization sequences for coronary bifurcation provisional stenting, including 1 novel sequence without kissing balloon inflation (KBI), comprising initial proximal optimizing technique (POT) + side-branch inflation (SBI) + final POT, called "re-POT." In provisional bifurcation stenting, KBI fails to improve the rate of major adverse cardiac events. Proximal geometric deformation increases the rate of in-stent restenosis and target lesion revascularization. A bifurcation bench model was used to compare KBI alone, KBI after POT, KBI with asymmetric inflation pressure after POT, and 2 sequences without KBI: initial POT plus SBI, and initial POT plus SBI with final POT (called "re-POT"). For each protocol, 5 stents were tested using 2 different drug-eluting stent designs: that is, a total of 60 tests. Compared with the classic KBI-only sequence and those associating POT with modified KBI, the re-POT sequence gave significantly (p < 0.05) better geometric results: it reduced SB ostium stent-strut obstruction from 23.2 ± 6.0% to 5.6 ± 8.3%, provided perfect proximal stent apposition with almost perfect circularity (ellipticity index reduced from 1.23 ± 0.02 to 1.04 ± 0.01), reduced proximal area overstretch from 24.2 ± 7.6% to 8.0 ± 0.4%, and reduced global strut malapposition from 40 ± 6.2% to 2.6 ± 1.4%. In comparison with 5 other techniques, the re-POT sequence significantly optimized the final result of provisional coronary bifurcation stenting, maintaining circular geometry while significantly reducing SB ostium strut obstruction and global strut malapposition. These experimental findings confirm that provisional stenting may be optimized more effectively without KBI using re-POT. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
External heating of stents by radio waves Pilot studies in rabbit aorta
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levitt, Adam B.; Robinson, Keith; Chronos, Nicolas A.F.
Purpose: This experiment was designed to assess the feasibility of radio frequency energy delivered by a prototype radio frequency generator inductive heating device (REVAX) positioned external to the body, for transient heating of stents after arterial implant. Methods and Materials: Twenty-one New Zealand White rabbits underwent stenting of their infrarenal aorta. Nine rabbits were stented and immediately placed in the REVAX for external stent heating with internal temperature probes in place. Twelve rabbits were stented and 3 days later either heated or placed in the generator as a sham for 20 min. The animals were terminated 28 days later. Results:more » The REVAX was able to heat the aortic stents in a controlled fashion; in Phase II experiments, the stent temperature was raised to 42 deg. C for 20 min. In Phase I mild necrosis was noted at the stent struts. In Phase II, necrosis and mineralization of the media was seen at the stent struts, and evidence of neointimal suppression was observed. Conclusion: This study demonstrated that external heating of stents in a blood vessel in a live animal via radio frequency energy is feasible. Further studies will be needed to assess whether any specific heating regimen might inhibit fibrocellular neointimal hyperplasia.« less
Mechanical behavior of deformed intravascular NiTi stents differing in design. Numerical simulation
NASA Astrophysics Data System (ADS)
Eremina, Galina M.; Smolin, Alexey Yu.; Krukovskii, Konstantin V.; Lotkov, Aleksandr I.; Kashin, Oleg A.; Kudryashov, Andrey N.
2017-12-01
Self-expanding intravascular NiTi stents serve to recover the lumen of vessels suffered from atherosclerotic stenosis. During their manufacturing or functioning in blood vessels, the stents experience different strains and local stresses that may result in dangerous defects or fracture. Here, using the method of movable cellular automata, we analyze how the design of a stent influences its stress state during shaping to a desired diameter on a mandrel. We consider repeated segments of different stents under two loads: uniform diametric expansion of their crown and expansion with relative displacements. The simulation data agree well with experiments, revealing critical strain, stress, and their localization sites at the shaping stage, and provide the way toward optimum stent designs to minimize the critical stress during shaping.
Argon plasma coagulation in the management of uncovered tracheal stent fracture
Ching, Yiu-Hei; Geck, Robert D.; Andrews, Arthur D.; Rumbak, Mark J.; Camporesi, Enrico M.
2014-01-01
Endotracheal and endobronchial stenting, particularly with uncovered stents, can be complicated by stent fracture, granulation tissue formation, direct airway injury, and airway obstruction. While stent removal is possible, it can result in significant complications and long-term benefit is not guaranteed. Argon plasma coagulation can be employed to trim fractured stent fragments and remove granulation tissue simultaneously. In this manuscript, we report a case and describe our experience with using this technique. PMID:26029557
Jeon, Pyoung; Kim, Byung Moon; Kim, Dong Joon; Kim, Dong I K; Park, Keun Young
2014-09-01
This study aimed to evaluate clinical and angiographic outcomes of Y-configuration double-stent-assisted (Y-stent) coiling using two closed-cell stents for wide-necked basilar tip aneurysm (BTA). A total of 25 patients underwent Y-stent coiling using two closed-cell stents as a first-time treatment in 18 (3 ruptured) BTAs, retreatment in 2 BTAs and as a third treatment in 5 wide-necked BTAs. Clinical and angiographic outcomes were evaluated retrospectively. Treatment-related complications were three (12.0 %) thromboembolic infarctions due to two acute in-stent thromboses and one embolism. Twenty-two (88 %) patients had favorable outcomes (modified Rankin scale score [mRS], 0-2) during the follow-up period (mean, 30 months; range, 6-54 months). Two patients died: one from initial subarachnoid hemorrhage and the other from intracerebral hemorrhage due to underlying Moyamoya disease. Post-treatment angiograms showed complete occlusion in nine aneurysms, residual neck in 11 aneurysms and residual sac in five aneurysms. Follow-up angiograms were available at least once between 5 to 34 months (mean, 16 months) in 21 patients. Nineteen patients showed improved or stable states (complete occlusion, n = 17; residual neck, n = 2). Major recurrences occurred in two BTAs (9.5 %). Those two major recurrent aneurysms had been large-sized aneurysms at the initial coiling procedure. Both showed not only coil compaction but also progressive growth to giant-sized aneurysms and intra-aneurysmal thrombus formation at the Y-stent coiling as a third-time treatment. Y-stent coiling using two closed-cell stents is a safe and durable treatment option for wide-necked BTA, but may have limited efficacy for large/giant sized and thrombosed aneurysms.
Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.
Win, Htut K; Caldera, Angel E; Maresh, Kelly; Lopez, John; Rihal, Charanjit S; Parikh, Manish A; Granada, Juan F; Marulkar, Sachin; Nassif, Deborah; Cohen, David J; Kleiman, Neal S
2007-05-09
Clinical trials that have excluded patients at high risk for cardiac events have led to commercial labeling approval of drug-eluting stents; nevertheless, such high-risk patients commonly undergo stent placement in clinical practice. The degree to which they experience cardiac events at a higher rate than non-high-risk patients is unclear. To assess the rates of major adverse cardiac events during the index admission and 1 year after the implantation of drug-eluting stents in patients with high-risk angiographic and clinical features. From July 2004 to September 2005, consecutive patients who underwent attempted stent placement at 42 different hospitals throughout the United States were enrolled in a prospective multicenter registry. We analyzed outcomes of 3323 patients who received at least 1 drug-eluting stent for a reason other than acute ST-segment elevation myocardial infarction. The study population was divided into 2 groups based on presence of at least 1 of 9 off-label characteristics based on the current US Food and Drug Administration-approved indications for sirolimus- and paclitaxel-eluting stents. The composite clinical outcomes of death, myocardial infarction, or target vessel revascularization during the index admission and death, myocardial infarction, or target lesion revascularization at 1 year were evaluated. Of the 3323 patients, 1817 (54.7%) had at least 1 off-label characteristic. During the index hospitalization, the composite clinical outcome occurred in 198 (10.9%) of patients in the off-label group and 76 (5.0%) of patients in the on-label group (adjusted odds ratio, 2.32; 95% confidence interval [CI], 1.75-3.07; P<.001). At 1 year, the composite clinical outcome occurred more often in the off-label group compared with the on-label group; 309 (17.5%) vs 131 (8.9%) (adjusted hazard ratio [HR], 2.16; 95% CI, 1.74-2.67; P<.001). Stent thrombosis also occurred more frequently among patients in the off-label group during the initial hospitalization (8 [0.4%] vs 0) and at 1 year: 29 (1.6%) vs 13 (0.9%), adjusted HR, 2.29 (95% CI, 1.02-5.16; P = .05). Compared with on-label use, off-label use of drug-eluting stents is associated with a higher rate of adverse outcomes during the index admission and at 1 year. Stent thrombosis occurred predominantly in patients who underwent off-label drug-eluting stent implantation. Clinicians should be cautious about extrapolating the benefits of drug-eluting stents over bare-metal stents observed in randomized clinical trials to higher-risk clinical settings that have not been assessed.
Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M
2008-11-01
To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.
Gillmann, Kevin; Mansouri, Kaweh; Bravetti, Giorgio Enrico; Mermoud, André
2018-06-05
In recent years microinvasive glaucoma surgery (MIGS) has risen in popularity. Amongst MIGS options is the XEN gel stent (Allergan Plc, Dublin, Ireland), a 45▒μm wide ab-interno microstent. It has proven effective in lowering IOP with low complication rates. However, XEN gel stents can become obstructed and cause postoperative rise in IOP. The causes and predicting factors for such obstructions still requires further research. We describe the case of a 69-year old male patient, with traumatic glaucoma and chronic intraocular inflammation demonstrated by laser flare photometry, following childhood trauma and anterior segment surgery. Uncontrollable IOP despite maximal antiglaucomatous therapy was managed with XEN-augmented Baerveldt surgery. Despite good initial filtration and IOP control, the XEN stent became obstructed and was surgically replaced. After a month, the new stent became obstructed and was replaced by a thicker-lumened Baerveldt tube. This restored good filtration, and adequate IOP was maintained post-operatively. Microscopic examination of the obstructed XEN stent showed a dense fibrin plug. This case report shows that fibrin formation could be an important factor in XEN gel stent obstruction, even in initially successfully filtering stents. The association of fibrinogenesis and intraocular inflammation could add a note of caution to the use of XEN gel stents in complicated cataract surgery, or advocate for aggressive anti-inflammatory treatments post-operatively. This could lead to a refinement in success predictors and better patient selection for XEN surgery. Finally, this could open the way to new management options for persistent obstructions, including pharmaceutical fibrinolysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuermann, Karl; Vorwerk, Dierk; Buecker, Arno
Purpose: To compare nonferromagnetic iliac artery prostheses in their suitability for patency monitoring with magnetic resonance angiography (MRA) using conventional angiography as a reference. Methods: In experiment 1, three Memotherm stents were inserted into the iliac arteries of each of six sheep: two 'tandem' stents on one side and a single stent on the other side. In experiment 2, four prostheses (normal and low-porosity Corvita stent-grafts, Memotherm, ZA-stent) were inserted in each of 11 sheep. Patency was monitored before and 1, 3, and 6 months after insertion with 3D phase-contrast and two 2D time-of-flight sequences (TOF-1: TR/TE = 18/6.9, TOF-2:more » 13/2.5) with and without contrast at 1.5 T. On 206 coronal MIP images (72 pre-, 134 post-stenting), three readers analyzed 824 iliac segments (206 x 4) for patency and artifacts. Results: There was no difference in the number of artifacts between tandem and single iliac Memotherm stents. The ZA-stent induced significantly fewer artifacts than the other prostheses (p < 0.00001). With MRA, patency of the ZA-stent was correctly diagnosed in 88% of cases, which was almost comparable to nonstented iliac segments (95%), patency of the Memotherm stent in 59%, and of the Corvita stent-grafts in 57% and 55%. The TOF-2 sequence with contrast yielded the best images. Conclusion: MRA compatibility of nonferromagnetic prostheses depends strongly on the design of the device. MRA may be used to monitor the patency of iliac ZA-stents, whereas iliac Memotherm stents and Corvita stent-grafts appear to be less suited for follow-up with MRA.« less
Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca
2012-10-15
Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.
Anton, Susanne; Stahlberg, Erik; Horn, Marco; Wiedner, Marcus; Kleemann, Markus; Barkhausen, Joerg; Goltz, Jan P
2018-04-01
To evaluate the safety and efficacy of a novel balloon-expandable stent-graft for endovascular treatment of visceral artery aneurysms (VAA). Between 9/2014 and 1/2017 seven patients (69±15 years) with true (N.=4) and false (N.=3) VAAs were treated by implantation of balloon-expandable stent-grafts (E-ventus®, Jotec, Hechingen, Germany) using a transfemoral (N.=2) or transbrachial (N.=5) vascular access. The stent-graft was placed without prior passing of the landing zone with a sheath. In 3 of 7 patients (42.9%) additional coil or plug embolization was performed to prevent retrograde VAA perfusion. Endpoints were technical success (defined as delivery and implantation of the stent-graft in the intended position with complete exclusion of the VAA), peri-procedural complications and patency. Mean diameters of true VAAs (splenic artery: N.=2, common hepatic artery: N.=1, celiac trunk: N.=1) were 26±9 and of false (common hepatic artery: N.=2, gastroduodenal artery: N.=1) 29±14 mm. False aneurysms presented as emergencies with active bleeding. Technical success was 100%. One peri-procedural complication was noted: pseudoaneurysm of the accessed brachial artery. After a mean follow-up of 187 days 6/7 stent-grafts (85.7%) were patent. One patient (fVAA) died two days after the emergency procedure owing to multi-organ failure which was assessed to be non-procedure-related. Another patient (fVAA) died 7 months from the procedure owing to cancer. Endovascular treatment of true and false visceral artery aneurysms by use of the E-ventus® stent-graft is safe and effective. Flexibility of the stent-graft and shaft allows for implantation without passing the lesion with a sheath, enabling treatment of distal as well as complex visceral lesions. Long-term results regarding patency in a larger patient cohort are needed to confirm these findings.
[The bioresorbable coronary stent: a revolution].
Koegler, Flora; De Benedetti, Edoardo
2013-04-10
Coronary angioplasty has undergone several technological revolutions: starting with balloon angioplasty, then with bare metal stent and finally with drug eluting stent (DES), this technique is now mature. However, once we thought the problem of instent restenosis solved with DES, new concerns arise with late and very late stent thrombosis. Should we therefore proscribe DES? How long should be the duration of dual antiplatelet therapy? And how should we manage the patients who need a surgery and are at high risk of bleeding? Are bioresorbable stents the final solution with their initial mechanical properties, then with their drug eluting effect against intra-stent restenosis, and finally with their complete resorption which leaves the artery free of any foreign material?
Immediate stent recoil in an anastomotic vein graft lesion treated by cutting balloon angioplasty.
Akkus, Nuri Ilker; Budeepalli, Jagan; Cilingiroglu, Mehmet
2013-11-01
Saphenous vein graft (SVG) anastomotic lesions can have significant fibromuscular hyperplasia and may be resistant to balloon angioplasty alone. Stents have been used successfully to treat these lesions. There are no reports of immediate stent recoil following such treatment in the literature. We describe immediate and persistent stent recoil in an anastomotic SVG lesion even after initial and post-deployment complete balloon dilatation of the stent and its successful treatment by cutting balloon angioplasty. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Behaviour of two typical stents towards a new stent evolution.
Simão, M; Ferreira, J M; Mora-Rodriguez, J; Fragata, J; Ramos, H M
2017-06-01
This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interaction are used to assess the haemodynamic impact of two types of coronary stents implantation: (1) type 1-based on a strut-link stent geometry and (2) type 2-a continuous helical stent. Using data from a recent clinical stenosis, flow disturbances and consequent shear stress alterations introduced by the stent treatment are investigated. A relationship between stenosis and the induced flow fields for the two types of stent designs is analysed as well as the correlation between haemodynamics and vessel wall biomechanical factors during the initiation and development of stenosis formation in the coronary artery. Both stents exhibit a good performance in reducing the obstruction artery. However, stent type 1 presents higher radial deformation than the type 2. This deformation can be seen as a limitation with a long-term clinical impact.
Kato, Hironari; Kawamoto, Hirofumi; Noma, Yasuhiro; Sonoyama, Takayuki; Tsutsumi, Koichiro; Fujii, Masakuni; Okada, Hiroyuki; Yamamoto, Kazuhide
2013-01-01
The endoscopic management of malignant hilar biliary strictures using multiple metallic stents (MS) is technically demanding, in the initial deployment of MS and the recovery from MS occlusion with deployment of multiple plastic stents (PS). We evaluated the outcomes of the application of a Soehendra stent retriever (SSR) as a dilator of intractable strictures. Fifty-nine patients with malignant hilar biliary strictures had multiple MS inserted using a partial stent-in-stent procedure. When we encountered intractable strictures, we adopted SSR to dilate the stricture and the interstice of the MS. We evaluated the success rate of MS or PS deployment after SSR application and procedural complications. Five of 59 patients (8%) were subjected to SSR application for the initial MS deployment. MS were successfully deployed in all of these patients (100%). MS occlusion was noted in 27 patients. We applied SSR to seven patients (26%) for the deployment of multiple PS after MS occlusion. In five patients (71%), successful PS deployment was achieved after the SSR application. No complications related to dilatation using SSR occurred in any patient. SSR proved to be a potent dilator of difficult strictures in the management of malignant hilar biliary strictures.
Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca; Saluja, Jasdeep S.
2007-07-15
Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm.more » The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is associated with good mid-term patency and may exceed historical observations with prior use of Wallstents.« less
Radaelli, A G; Augsburger, L; Cebral, J R; Ohta, M; Rüfenacht, D A; Balossino, R; Benndorf, G; Hose, D R; Marzo, A; Metcalfe, R; Mortier, P; Mut, F; Reymond, P; Socci, L; Verhegghe, B; Frangi, A F
2008-07-19
This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and interventional planning.
NASA Astrophysics Data System (ADS)
Boland, Enda L.; Grogan, James A.; Conway, Claire; McHugh, Peter E.
2016-04-01
Coronary stents have revolutionised the treatment of coronary artery disease. While coronary artery stenting is now relatively mature, significant scientific and technological challenges still remain. One of the most fertile technological growth areas is biodegradable stents; here, there is the possibility to generate stents that will break down in the body once the initial necessary scaffolding period is past (6-12 months) (Grogan et al. in Acta Biomater 7:3523, 2011) and when the artery has remodelled (including the formation of neo-intima). A stent angioplasty computational test-bed has been developed by the authors, based on the Abaqus software (DS-SIMULIA, USA), capable of simulating stent tracking, balloon expansion, recoil and in vivo loading in a atherosclerotic artery model. Additionally, a surface corrosion model to simulate uniform and pitting corrosion of biodegradable stents and a representation of the active response of the arterial tissue following stent implantation, i.e. neointimal remodelling, has been developed. The arterial neointimal remodelling simulations with biodegradable stent corrosion demonstrate that the development of new arterial tissue around the stent struts has a substantial effect on the mechanical behaviour of degrading stents.
Antegrade Ureteral Stenting is a Good Alternative for the Retrograde Approach.
van der Meer, Rutger W; Weltings, Saskia; van Erkel, Arian R; Roshani, Hossain; Elzevier, Henk W; van Dijk, Lukas C; van Overhagen, Hans
2017-07-01
Double J (JJ) stents for treating obstructive ureteral pathology are generally inserted through a retrograde route with cystoscopic guidance. Antegrade percutaneous insertion using fluoroscopy can be performed alternatively but is less known. Indications, success rate and complications of antegrade ureteral stenting were evaluated. Data of consecutive patients in which antegrade ureteral stenting was performed were retrospectively analysed using the radiology information system and patient records. Patient characteristics, details of the antegrade JJ stent insertion procedure and registered complications were collected. Furthermore, it was investigated if prior to the antegrade procedure a retrograde attempt for JJ stent insertion was performed. Total 130 attempts for antegrade JJ stent insertion were performed in 100 patients. A percutaneous nephrostomy catheter had already been placed in the majority of kidneys (n = 109) for initial treatment of hydronephrosis. Most prevelant indication for a JJ stent was obstructive ureteral pathology due to malignancy (n = 63). A JJ stent was successfully inserted in 125 of 130 procedures. In 21 cases, previous retrograde ureteral stenting had failed but, subsequent antegrade ureteral stenting was successful. There were 8 procedure related complications; 6 infections, 1 false tract and 1 malposition. Antegrade percutaneous insertion of a JJ stent is a good alternative for retrograde insertion.
When Not to Go SOLO? Contraindications Based on Implant Experience.
Wollersheim, Laurens W; Li, Wilson W; Kaya, Abdullah; van Boven, Wim J; van der Meulen, Jan; de Mol, Bas A
2016-11-01
Because of the design and specific implantation technique of the stentless Freedom SOLO bioprosthesis, patient selection is crucial. The aim of the study was to discuss the contraindications to this prosthesis based on the authors' implant experience. Between April 2005 and February 2015, one surgeon at the authors' center performed 292 aortic valve replacements using a bioprosthesis, with the initial intention of implanting a SOLO valve in every patient. A search was conducted for all of these patients and data collected on whether a SOLO valve was used, or not. A SOLO valve was implanted in 238 patients (82%), and a stented bioprosthesis in 54 (18%). The predominant reasons not to implant a SOLO valve were asymmetric commissures (26%) and a large aortic annulus (24%). Only one patient had structural valve deterioration, and none of the patients had to undergo reoperation because of aortic valve insufficiency or paravalvular leakage. Asymmetric commissures, large aortic annulus (>27 mm), calcified aortic sinuses, dilated sinotubular junction, aberrant location of coronary ostia and whenever the stent of a stented bioprosthesis is useful, were contraindications to implant a SOLO valve. When these contraindications were taken into account, a very good durability could be achieved with the SOLO valve during mid-term follow up.
Tsugawa, C; Nishijima, E; Muraji, T; Yoshimura, M; Tsubota, N; Asano, H
1997-01-01
The authors have designed a coil airway stent using a thermal shape-memory titanium-nickel alloy (SMA) to relieve airway collapse in children. A characteristic of alloy allowed the stent to be enclosed in the thin introducer tube and to position it bronchoscopically in the collapsed airway. When the stent is warmed to 37 to 40 degrees C, it expands to the memorized diameter and stents the airway. In eight rabbits, an experimental model of potentially fatal tracheomalacia was created by fracturing the tracheal cartilages. The stents of 6 mm in diameter and 15 mm in length were placed, and then the stents were recovered to their original shape within 1 minute. All rabbits except one showed no respiratory symptoms during the follow-up period. Results of bronchoscopy performed 6 and 10 months after implantation showed satisfactory patency of the trachea. The rabbits were killed for histological evaluation 6 to 28 months after implantation. The specimens showed little proliferation of granulation and no dislodgement of the stents. This procedure was attempted in two children who had severe bronchomalacia. One 5-year-old patient underwent implantation with a stent of 5 mm in diameter and 25 mm in length into the left main bronchus. The patient was relieved from apneic attacks. The stent was removed 2 years after implantation after a remarkable improvement of ventilation. The other patient with left bronchomalacia, age 1 year 2 months, underwent implantation with a 5-mm x 20-mm stent. The animal experiment and clinical experience indicated that (1) this stent can be easily inserted and removed bronchoscopically, (2) the stent has good tissue compatibility and little interference of mucociliary function, and (3) the SMA stent is a promising therapeutic adjunct in the management of children with severe tracheobronchomalacia.
Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sofue, Keitaro, E-mail: keitarosofue@yahoo.co.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp
A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.
Quantification of abdominal aortic deformation after EVAR
NASA Astrophysics Data System (ADS)
Demirci, Stefanie; Manstad-Hulaas, Frode; Navab, Nassir
2009-02-01
Quantification of abdominal aortic deformation is an important requirement for the evaluation of endovascular stenting procedures and the further refinement of stent graft design. During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and, the stent graft. This deformation can affect the flow characteristics and morphology of the aorta which have been shown to be elicitors for stent graft failures and be reason for reappearance of aneurysms. We present a method for quantifying the deformation of an aneurysmatic aorta imposed by an inserted stent graft device. The outline of the procedure includes initial rigid alignment of the two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. This is accomplished by preprocessing and remodeling of the pre- and postoperative aortic shapes before performing a non-rigid registration. We further narrow the resulting displacement fields to only include local non-rigid deformation and therefore, eliminate all remaining global rigid transformations. Finally, deformations for specified locations can be calculated from the resulting displacement fields. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results and evaluation of the usage of deformation quantification were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.
Stent grafts for the treatment of abdominal aortic aneurysms.
Diethrich, Edward B
2003-01-01
Stent grafting for treatment of abdominal aortic aneurysms (AAAs) has been a major advance in endovascular surgery. Initial success with the original endoluminal stent graft encouraged worldwide study of the technology. In the United States, the Food and Drug Administration (FDA) insisted on considerable experience with the devices before approval because of early problems with device rupture, stent fracture, fabric perforation, graft migration, and modular separation. Complications associated with the endovascular graft technology led many to recommend its use only in patients who were considered at "high risk" for the standard, open procedure. Further study and device improvements have led to results that indicate the procedure has the potential to reduce operating time and blood loss and shorten intensive care unit and hospital stays compared with open surgical intervention. At present, there are three FDA-approved devices available for use, and a fourth is expected in 2003. The ultimate decision by the individual practitioner or the institutional team regarding which patients should be treated with endovascular technology is still not entirely straightforward. Patient selection should be based on vascular anatomy, the availability of a suitable device, the patient's desire for a minimally invasive procedure, and a commitment to what is likely to be a lifetime of device surveillance.
Kida, M; Miyazawa, S; Iwai, T; Ikeda, H; Takezawa, M; Kikuchi, H; Watanabe, M; Imaizumi, H; Koizumi, W
2011-12-01
Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Occlusion of covered metallic stents now occurs in about half of all patients with malignant biliary strictures. The removal of metallic stents followed by placement of a second stent has been attempted, but outcomes remain controversial. The aim of the current study was to evaluate the effectiveness and safety of the primary placement and secondary placement (re-intervention) of covered metallic stents and to assess the feasibility and safety of stent removal. The study included 186 patients with unresectable malignant biliary strictures who underwent primary stent placement between October 2001 and March 2010. Covered biliary self-expandable metal stents (SEMSs) were removed in 39 of these patients, and 36 underwent re-intervention. The patency times, occlusion rates of the first stent and re-intervention, success rates of stent removal, and complications were investigated. Covered SEMSs were placed in 186 patients. The median patency time of the first stent was 352 days. Stent occlusion occurred in 48.9 % of the patients and was mainly caused by debris or food residue (37 %), dislocation (19 %), and migration with hyperplasia (19 %). Stent removal was attempted in 50 patients and was successful without complication in 39 (78 %). Most of the patients in whom stent removal was unsuccessful had migration with hyperplasia. The median patency time of the second stent was 263 days. The stent patency time did not significantly differ between the first and the second stent. Covered SEMSs could be safely removed at the time of stent occlusion. Patency rates were similar for initial stent placement and re-intervention. © Georg Thieme Verlag KG Stuttgart · New York.
Chung, Sun Young; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul
2010-01-01
Objective To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. Materials and Methods A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. Results One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. Conclusion The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval. PMID:20191062
Influence of strut cross-section of stents on local hemodynamics in stented arteries
NASA Astrophysics Data System (ADS)
Jiang, Yongfei; Zhang, Jun; Zhao, Wanhua
2016-05-01
Stenting is a very effective treatment for stenotic vascular diseases, but vascular geometries altered by stent implantation may lead to flow disturbances which play an important role in the initiation and progression of restenosis, especially in the near wall in stented arterial regions. So stent designs have become one of the indispensable factors needed to be considered for reducing the flow disturbances. In this paper, the structural designs of strut cross-section are considered as an aspect of stent designs to be studied in details. Six virtual stents with different strut cross-section are designed for deployments in the same ideal arterial model. Computational fluid dynamics (CFD) methods are performed to study how the shape and the aspect ratio (AR) of strut cross-section modified the local hemodynamics in the stented segments. The results indicate that stents with different strut cross-sections have different influence on the hemodynamics. Stents with streamlined cross-sectional struts for circular arc or elliptical arc can significantly enhance wall shear stress (WSS) in the stented segments, and reduce the flow disturbances around stent struts. The performances of stents with streamlined cross-sectional struts are better than that of stents with non-streamlined cross-sectional struts for rectangle. The results also show that stents with a larger AR cross-section are more conductive to improve the blood flow. The present study provides an understanding of the flow physics in the vicinity of stent struts and indicates that the shape and AR of strut cross-section ought to be considered as important factors to minimize flow disturbance in stent designs.
Allium Stents: A Novel Solution for the Management of Upper and Lower Urinary Tract Strictures
Bahouth, Zaher; Moskovitz, Boaz; Halachmi, Sarel; Nativ, Ofer
2017-01-01
Stents are widely use in endoscopic urological procedures. One of the most important indications is the treatment of urinary tract strictures. Allium™ Medical has introduced several types of stents for the treatment of different types of urinary tract strictures, based on anatomic location. All the stents are made of nitinol and coated with a co-polymer that reduces encrustations. These stents are self-expandable and have a large caliber and a high radial force. They have different shapes, designed especially for the treatment of each type of stricture. One of the most important features of Allium-manufactured stents is the ease of removal, due to their special unraveling feature. The company has introduced the Bulbar Urethral Stent (BUS) for treatment of bulbar urethral strictures; a rounded stent available in different lengths. Initial data on 64 patients with bulbar urethral stricture treated with the BUS showed a significant improvement in symptoms, with minimal complications and few adverse events. For treatment of prostate obstruction in patients unfit for surgery or unwilling to undergo a classical prostatic surgery, the Triangular Prostatic Stent (TPS) was introduced, which has a triangular shape that fits in the prostatic urethra. Its body has a high radial force attached to an anchor (which prevents migration) through a trans-sphincteric wire (which reduces incontinence rate). Initial data on 51 patients showed significant improvement in symptoms and in urinary peak flow rate, with a relatively small number of complications. The Round Posterior Stent (RPS) was designed for treatment of post radical prostatectomy bladder neck contracture. This short, round stent has an anchor, which is placed in the bladder neck. This stent being relatively new, the clinical data are still limited. Ureteral strictures can be treated with the Ureteral Stent (URS), which is round-shaped, available in different lengths, and has an anchor option (for very distal or very proximal strictures). We have previously published data on 107 URSs inserted in patients with ureteral stricture due to several etiologies, including patients who failed previous treatment. All patients were asymptomatic for a long period of follow-up after stent removal, with only one case of re-stenosis. In this paper, we review the urological “covered” stents produced by Allium Medical with the relevant clinical data available at the present time. PMID:28872453
Allium Stents: A Novel Solution for the Management of Upper and Lower Urinary Tract Strictures.
Bahouth, Zaher; Moskovitz, Boaz; Halachmi, Sarel; Nativ, Ofer
2017-10-16
Stents are widely use in endoscopic urological procedures. One of the most important indications is the treatment of urinary tract strictures. Allium™ Medical has introduced several types of stents for the treatment of different types of urinary tract strictures, based on anatomic location. All the stents are made of nitinol and coated with a co-polymer that reduces encrustations. These stents are self-expandable and have a large caliber and a high radial force. They have different shapes, designed especially for the treatment of each type of stricture. One of the most important features of Allium-manufactured stents is the ease of removal, due to their special unraveling feature. The company has introduced the Bulbar Urethral Stent (BUS) for treatment of bulbar urethral strictures; a rounded stent available in different lengths. Initial data on 64 patients with bulbar urethral stricture treated with the BUS showed a significant improvement in symptoms, with minimal complications and few adverse events. For treatment of prostate obstruction in patients unfit for surgery or unwilling to undergo a classical prostatic surgery, the Triangular Prostatic Stent (TPS) was introduced, which has a triangular shape that fits in the prostatic urethra. Its body has a high radial force attached to an anchor (which prevents migration) through a trans-sphincteric wire (which reduces incontinence rate). Initial data on 51 patients showed significant improvement in symptoms and in urinary peak flow rate, with a relatively small number of complications. The Round Posterior Stent (RPS) was designed for treatment of post radical prostatectomy bladder neck contracture. This short, round stent has an anchor, which is placed in the bladder neck. This stent being relatively new, the clinical data are still limited. Ureteral strictures can be treated with the Ureteral Stent (URS), which is round-shaped, available in different lengths, and has an anchor option (for very distal or very proximal strictures). We have previously published data on 107 URSs inserted in patients with ureteral stricture due to several etiologies, including patients who failed previous treatment. All patients were asymptomatic for a long period of follow-up after stent removal, with only one case of re-stenosis. In this paper, we review the urological "covered" stents produced by Allium Medical with the relevant clinical data available at the present time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Tian-Tian, E-mail: matthewwu1979@126.com; Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com; Zheng, Fang, E-mail: fang-zheng-surgery@126.com
PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portalmore » stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.« less
Management of benign dynamic "A-shape" tracheal stenosis: a retrospective study of 60 patients.
Plojoux, Jérôme; Laroumagne, Sophie; Vandemoortele, Thomas; Astoul, Philippe J; Thomas, Pascal A; Dutau, Hervé
2015-02-01
Benign tracheal stenosis complicates tracheal intubation or tracheostomy in 0.6% to 65% of cases. Surgical resection is the standard treatment. Endoscopic management is used for inoperable patients with 17% to 69% success. Dynamic "A-shape" tracheal stenosis (DATS) results in a dynamic stenosis with anterior fracture of tracheal cartilage and frequently associated posterior malacia. We report the results of our multidisciplinary management. Sixty patients with DATS were included. Management decision was made during initial bronchoscopy. When suitable, patients were referred to thoracic surgery for tracheal resection. Posterior localized tracheomalacia was treated with laser photocoagulation of the posterior tracheal wall. Tracheal stents were placed if the stenosis persisted after laser treatment. The choice of stent (straight silicone, hour-glass shaped silicone, T-tube, or fully-covered self-expandable metallic stent) was based on operator's judgment. After 12 to 18 months, stents were removed. If the stenosis persisted after stent removal, surgery was reconsidered. If surgery was not possible, a stent was replaced. In case of satisfactory result, a stent was replaced only after recurrence. Stable patients after treatment were considered as success, requirement of long-term tracheostomy or T tube as failure, and long-term stent as partial success. All patients developed DATS after tracheostomy. Thirty-three patients had posterior tracheomalacia. In 13 patients, mild stenosis required only endoscopic surveillance. Two patients were referred to thoracic surgery for tracheal resection surgery. Endoscopic management was the initial therapy in 45 patients (75%) and was considered successful in 23 patients (51%), partially successful in 10 (22%), and failed in 12 (27%). Five patients with successful outcomes required only laser therapy. Overall 70 stents were placed in 35 patients, with a migration rate of 31%. The DATS management was successful in 63%. Stent migration was frequent. Posterior tracheomalacia was successfully treated in selected cases, avoiding stent placement. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Baptista-Sincos, Anna Paula Weinhardt; Simplício, Aline Bigatão; Sincos, Igor Rafael; Leaderman, Alex; Neto, Fernando Saliture; Moraes, Adjaldes; Aun, Ricardo
2018-01-01
The endovascular technique has been recommended over the past few years to extracranial carotid dissection and pseudoaneurysm with promising results, especially after medical therapy failure. Flow-diverting stents are an alternative for complex cases. These stents have proven to be effective treatment devices for intracranial aneurysms. The reference list of Pham's systematic review, published in 2011, and Seward's literature review, published in 2015, was considered, as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE and Literatura Latino-Americana e do Caribe em Ciências da Saúde. For carotid dissection and pseudoaneurysm, our review yielded 3 published articles including 12 patients. The technical success rate of flow-diverting stent was 100% with no procedural complication described. Mean clinical follow-up was 27.2 months (range 5-48), and in 5 months' angiographic follow-up, all lesions had healed. No new neurological events were reported during the clinical follow-up. Flow diverter stent use on intracranial and peripheral vascular surgery demonstrates satisfactory initial results, but it is still under investigation. There are very few cases treated till now and the initial results with flow-diverting stents to cervical carotid dissection are promising. In well-selected cases, where simple embolization or conventional stent is not appropriate, this technic may be considered. Copyright © 2017 Elsevier Inc. All rights reserved.
Antegrade Ureteral Stenting is a Good Alternative for the Retrograde Approach
van der Meer, Rutger W.; Weltings, Saskia; van Erkel, Arian R.; Roshani, Hossain; Elzevier, Henk W.; van Dijk, Lukas C.; van Overhagen, Hans
2017-01-01
Background/Aims Double J (JJ) stents for treating obstructive ureteral pathology are generally inserted through a retrograde route with cystoscopic guidance. Antegrade percutaneous insertion using fluoroscopy can be performed alternatively but is less known. Indications, success rate and complications of antegrade ureteral stenting were evaluated. Methods Data of consecutive patients in which antegrade ureteral stenting was performed were retrospectively analysed using the radiology information system and patient records. Patient characteristics, details of the antegrade JJ stent insertion procedure and registered complications were collected. Furthermore, it was investigated if prior to the antegrade procedure a retrograde attempt for JJ stent insertion was performed. Results Total 130 attempts for antegrade JJ stent insertion were performed in 100 patients. A percutaneous nephrostomy catheter had already been placed in the majority of kidneys (n = 109) for initial treatment of hydronephrosis. Most prevelant indication for a JJ stent was obstructive ureteral pathology due to malignancy (n = 63). A JJ stent was successfully inserted in 125 of 130 procedures. In 21 cases, previous retrograde ureteral stenting had failed but, subsequent antegrade ureteral stenting was successful. There were 8 procedure related complications; 6 infections, 1 false tract and 1 malposition. Conclusion Antegrade percutaneous insertion of a JJ stent is a good alternative for retrograde insertion. PMID:28785193
Marković, B B; Marković, Z; Yachia, D; Hadzi, Djokić J
2007-01-01
A number of urethral stents made of different materials, with different time of indwelling and different designs, primarily based on the vascular stent concept, have been applied in the clinical practice so far. According to the published studies, urethral stents have justified their clinical application, however with certain limitations. Within an attempt to overcome the limitations, a covered, temporary urethral stent was initially designed by Daniel Yachie and Ijko Markovi in Allium corporation from Israel. With its triangular shape, the stent is a replica of the obstructive prostatic urethral lumen. In has been applied in a series of 14 patients with lower urinary tract symptoms caused by the obstruction at the level of the prostatic urethra. The subjects were averagely aged 77.4 +/- 5.1 years. Allium prostatic stent remained in place in the patients for 4.93 +/- 3.17 months, at the average.
Ghaed, Mohammad Ali; Daniali, Maziar; Ebrahimian, Mohammad
2018-05-03
Malignant ureteral obstruction is usually caused by an extrinsic compression including intra-abdominal cancers. One of the treatment modalities decompressing the obstruction is applying stent to open the ureter. Metallic Stent is an effective instrument which we used for the first time in Iran in our patient who had a metastatic colon cancerwith a single kidney and we used a Novel, Double-Layered, Coated, Self-expandable Metallic Mesh Stent (Uventa Stent) to keep the ureter open. After six months of follow up with ureteroscopy, there was no obstruction any more.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Charles Y., E-mail: charles.kim@duke.edu; Tandberg, Daniel J.; Rosenberg, Michael D.
2012-08-15
Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metalmore » stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.« less
[Myocardial ischemia in general medicine and the revolution of coronary stents].
El-Mourad, M; Merveille, P; Preumont, N
2014-09-01
Since Gruentizg's first percutaneous transluminal ballon angioplasty in 1977 in Zurich, percuta. neous coronary intervention evolved significantly in order to overcome the numerous associated complications of each technique. Bare-metal stents (BMS) made their initial appearance followed by three generations of drug-eluting stents (DES). The use of bioabsorbable vascular scaffold stents (BVS) has become more frequent creating a temporary scaffold allowing healing of the endothelium within 2 years. In this article, we discuss the nomenclature of the main intravascular complications linked to percuta. neous coronary intervention such as stent thrombosis (ST), Instent restenosis (ISR), neoatherosclerosis, and stents evolution to overcome these complications. We will finally mention the new technologies of intracoronary imaging such as OCT (Optical Coherence Tomography) having an increasing vital role in percutaneous coronary intervention,
Mukai, Shuntaro; Itoi, Takao; Baron, Todd H; Sofuni, Atsushi; Itokawa, Fumihide; Kurihara, Toshio; Tsuchiya, Takayoshi; Ishii, Kentaro; Tsuji, Shujiro; Ikeuchi, Nobuhito; Tanaka, Reina; Umeda, Junko; Tonozuka, Ryosuke; Honjo, Mitsuyoshi; Gotoda, Takuji; Moriyasu, Fuminori; Yasuda, Ichiro
2015-01-01
Recently, a novel fully covered and biflanged metal stent (BFMS)dedicated to the drainage of walled-off necrosis(WON) was developed. The aim of this study was to retrospectively evaluate the safety, efficacy, and cost performance of drainage of WON using the novel BFMS compared with a traditional plastic stent. A total of 70 patients with symptomatic WON were treated under endoscopic ultrasound (EUS) guidance. Initial drainage was conducted using the single gateway technique with placement of one or more plastic stents or a single BFMS.If drainage was unsuccessful,direct endoscopic necrosectomy (DEN)was performed. There were no statistically significant differences in rates of technical success, clinical success,and adverse events between plastics stents and BFMS, despite the size of WON in the BFMS group being significantly larger than that in the plastic stent group (105.6 vs. 77.1 mm; P=0.003).The mean procedure times for the first EUS-guided drainage and for re-intervention were significantly shorter in the BFMS group than in the plastic stent group (28.8±7.1 vs. 42.6±14.2, respectively,for drainage, P<0.001; and 34.9±8.5 vs.41.8±7.6, respectively, for re-intervention, P<0.001). There was no statistically significant difference in the total cost between plastic stent and BFMS use in the treatment of WON ($5352vs. $6274; P=0.25). Plastic stents and BFMS were safe and effective for the treatment of WON. In particular,BFMS placement appeared to be preferable for initial EUS-guided drainage and additional reintervention(e.g. DEN) as it reduced the procedure time. Prospective randomized controlled trials are warranted.
Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan
2014-03-01
Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P < 0.001). Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Goltz, Jan P; Ritter, Christian O; Kellersmann, Richard; Klein, Detlef; Hahn, Dietbert; Kickuth, Ralph
2012-06-01
To evaluate efficacy, safety, and midterm patency of a helical, self-expanding nitinol stent after failed percutaneous transluminal angioplasty (PTA) of popliteal artery segments P1 and P2 in patients with chronic critical limb ischemia (CLI) or lifestyle-limiting claudication. Between February 2009 and March 2011, 40 patients (23 men; mean age 77±10 years) classified as Rutherford category 3 (n = 10) or 4/5 (n = 30) underwent PTA of the proximal and mid popliteal artery followed by implantation of a SUPERA stent for elastic recoil, residual stenosis, or flow-limiting dissection. All patients had an elevated operative risk. Before and after the procedure and during the 12-month follow-up, a clinical investigation, ankle-brachial-index (ABI) measurement, and color-coded duplex sonography and/or digital subtraction angiography were performed. Primary endpoints were limb salvage and anatomical patency at 12 months. Stent implantation was successful in all patients. The major complication rate was 7.5% (an access-site pseudoaneurysm, 2 retroperitoneal hematomas, and 1 death from retroperitoneal bleeding). Mean follow-up was 15.9 months (range 0.5-27.9). The mean baseline ABI of 0.37 significantly increased to 0.91 at 12 months (p<0.01). Three (7.5%) patients underwent bypass surgery owing to lack of clinical improvement (<0.10 improvement in ABI). Primary and secondary patency rates at 12 months in the 34 patients eligible for follow-up were 68.4% and 79.8%, respectively. The major amputation rate was 5% at 1 year. Five (12.5%) in-stent stenoses and 1 of 2 (5.0%) in-stent occlusions were successfully recanalized (the second occlusion was asymptomatic). Implantation of this helical stent into segments of the popliteal artery at the knee joint in CLI patients is a safe and clinically effective bailout method with acceptable intermediate patency.
Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L
2010-01-01
Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.
Lee, Tae Hoon; Park, Do Hyun; Lee, Sang Soo; Choi, Hyun Jong; Lee, Jun Kyu; Kim, Tae Hyeon; Kim, Jong Hyeok; Jeong, Seok; Park, Sang-Heum; Moon, Jong Ho
2013-02-01
Theoretically, the side-by-side bilateral placement of metal stents may be technically easier than stent-in-stent bilateral placement in stent revision. However, side-by-side placement can be technically challenging, as the deployment of the first stent can preclude the passage of the second stent. We explored the technical feasibility and revision efficacy of endoscopic bilateral side-by-side stent placement for malignant hilar biliary strictures. Forty-four patients with Bismuth type II or higher malignant hilar biliary strictures were enrolled in seven academic tertiary referral centers. Endoscopic placement of side-by-side bilateral metal stents with 7F thin delivery shaft was performed. The outcome measurements were the technical and functional success, adverse events, endoscopic revision success rate, and stent patency. Overall, the technical and functional success rates were 91 % (40/44), and 98 % (39/40), respectively. Two of the failed patients were converted successfully with subsequent contralateral stent-in-stent placement, and the other patients underwent percutaneous intervention. Early stent-related adverse events occurred in 10 %. The endoscopic revision rate due to stent malfunction during follow-up (median: 180 days) was 45 % (18/40; tumor ingrowth in 4 and in-stent sludge impaction/stone formation in 14 patients). The endoscopic revision success rate was 92 % (12/13). Five patients with comorbidity underwent initial percutaneous intervention. The median survival and stent patency periods were 180 and 157 days, respectively. The sequential placement of a metal stent with a 7F thin delivery shaft in bilateral side-by-side procedures may be feasible and effective for malignant hilar biliary strictures and for endoscopic stent revision.
Di Mitri, R; Mocciaro, F
2014-01-01
Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Twenty patients (9 males) were treated (mean age 64.2 ± 15.3 years). The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%), IIIa in 1 (5%), and IV in 14 (70%). The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL). One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months), 13 of the 20 patients (65%) had died. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration) as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.
Internal stenting in malignant biliary obstruction.
Cowling, M G; Adam, A N
2001-03-01
Internal stenting in inoperable malignant biliary obstruction plays an important role in patient management. Surgical bypass may still be undertaken where there is also duodenal obstruction, though the need for gastroenterostomy may be reduced with the increasing use of metallic stents for the relief of malignant gastric outlet obstruction. Stents may be placed endoscopically or percutaneously, though in most centers the endoscopic route is usually tried first, with the percutaneous route being reserved for endoscopic failures. Plastic and self-expanding metallic biliary stents are available, each with its own advantages and disadvantages. In general, longer periods of patency are observed with metallic stents, though they are more expensive. Plastic stents can be changed endoscopically relatively easily when they have blocked, and in practice it is common for plastic stents to be inserted via this route for initial biliary drainage. If there is prolonged survival thereafter, many workers insert a metallic stent in an attempt to reduce the number of interventions required. If the percutaneous route is being employed, the histologic diagnosis has been confirmed, and the malignancy is inoperable, our practice is to use a self-expanding metallic stent, as the delivery system is relatively small and subsequent occlusion less likely.
Sequential Stenting for Extensive Malignant Airway Stenosis
Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Tei, Keiko; Yamamoto, Ryoji
2014-01-01
Purpose: Malignant airway stenosis extending from the bronchial bifurcation to the lower lobar orifice was treated with airway stenting. We herein examine the effectiveness of airway stenting for extensive malignant airway stenosis. Methods: Twelve patients with extensive malignant airway stenosis underwent placement of a silicone Dumon Y stent (Novatech, La Ciotat, France) at the tracheal bifurcation and a metallic Spiral Z-stent (Medico’s Hirata, Osaka, Japan) at either distal side of the Y stent. We retrospectively analyzed the therapeutic efficacy of the sequential placement of these silicone and metallic stents in these 12 patients. Results: The primary disease was lung cancer in eight patients, breast cancer in two patients, tracheal cancer in one patient, and thyroid cancer in one patient. The median survival period after airway stent placement was 46 days. The Hugh–Jones classification and performance status improved in nine patients after airway stenting. One patient had prolonged hemoptysis and died of respiratory tract hemorrhage 15 days after the treatment. Conclusion: Because the initial disease was advanced and aggressive, the prognosis after sequential airway stent placement was significantly poor. However, because respiratory distress decreased after the treatment in most patients, this treatment may be acceptable for selected patients with extensive malignant airway stenosis. PMID:25273272
Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua
2015-05-01
The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R
2016-09-01
Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.
Modified jailed balloon technique for bifurcation lesions.
Saito, Shigeru; Shishido, Koki; Moriyama, Noriaki; Ochiai, Tomoki; Mizuno, Shingo; Yamanaka, Futoshi; Sugitatsu, Kazuya; Tobita, Kazuki; Matsumi, Junya; Tanaka, Yutaka; Murakami, Masato
2017-12-04
We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting. © 2017 Wiley Periodicals, Inc.
[Expandable stents and composite prosthesis].
Baldeyrou, P
1999-11-01
Today, numerous expandable and mixed silicone metallic stents for trachea and bronchi are available. Among the many technical propositions, Nitinol is a new alloy with promising potential, offering the advantage of shape memory. The right stent is the one which best meets the needs of the individual stenotic situation as evaluated by endoscopy and CT. Sufficient experience has been acquired only with the Dumon stent, giving exact information about its qualities and possible complications. The new stents are thinner. Some can be inserted under fluoroscopic and fibroscopic control. They are presumed to produce fewer complications an provide answers to some still unresolved questions such as dyskinesia or stenosis on short bronchi. They appear to be more easily inserted on the tracheo-bronchial tree. More experience is needed to satisfactorily identify specific indications and contraindications. A prospective registry will be important to obtain comparative information more quickly.
Marković, Z; Masulović, D; Markovic, B; Anojcić, P; Mladenović, A
2009-01-01
At the current level of stent application in urology each irreversible urostasis contraindicated for surgical therapy implies consideration of indications for metal stent insertion. Stent incrustation which leads directly into a new uroobstruction is a characteristic complication of this method. Available experience in different uroobstructive conditions has shown that very different clinical aspects of stent usage may directly determine the possibility of their incrustation. Stent incrustation may occur in the early postprocedural course or several months later. After that, prevention of stent incrustation starts with postprocedural evaluation, selection of the stent type, and it is subsequently continued by insertion technique and lasts practically permanently after the insertion (infection control, promotion of diuresis and maintenance of normal urodynamics). Authors present own experianse in clinical aplication of metal stents in uroradiology strictures for period of last 15 years.
Carotid Artery Stenting: Single-Center Experience Over 11 Years
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nolz, Richard, E-mail: richard.nolz@meduniwien.ac.at; Schernthaner, Ruediger Egbert, E-mail: ruediger.schernthaner@meduniwien.ac.a; Cejna, Manfred, E-mail: manfred.cejna@lkhf.a
2010-04-15
This article reports the results of carotid artery stenting during an 11-year period. Data from 168 carotid artery stenting procedures (symptomatic, n = 55; asymptomatic, n = 101; symptoms not accessible, n = 12) were retrospectively collected. Primary technical success rate, neurological events in-hospital, access-site complications, and contrast-induced nephropathy (n = 118) were evaluated. To evaluate the influence of experience in carotid artery stenting on intraprocedural neurologic complications, patients were divided into two groups. Group 1 included the first 80 treated patients, and group 2 the remainder of the patients (n = 88). In-stent restenoses at last-follow-up examinations (n =more » 89) were assessed. The overall primary technical success rate was 95.8%. The in-hospital stroke-death rate was 3.0% (n = 5; symptomatic, 5.4%; asymptomatic, 2.0%; p = 0.346). Neurologic complications were markedly higher in group 1 (4.2%; three major strokes; symptomatic, 2.8%, asymptomatic, 1.4%) compared to group 2 (2.4%; one major and one minor stroke-symptomatic, 1.2%, asymptomatic 1.2%), but this was not statistically significant. Further complications were access-site complications in 12 (7.1%), with surgical revision required in 1 (0.6%) and mild contrast-induced nephropathy in 1 (0.85%). Twenty-one (23.6%) patients had >50% in-stent restenosis during a mean follow-up of 28.2 months. In conclusion, advanced experience in carotid artery stenting leads to an acceptable periprocedural stroke-death rate. In-stent restenosis could be a critical factor during the follow-up course.« less
Malignant biliary disease: percutaneous interventions.
Morgan, R A; Adam, A N
2001-09-01
Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company
Pneumoperitoneum Caused by Transhepatic Air Leak After Metallic Biliary Stent Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jei Hee; Lee, Deok Hee; Yu, Jeong-Sik
2000-11-15
A self-expanding metallic biliary stent was placed for palliation of a common bile duct obstruction in a 68-year-old male with unresectable pancreatic head cancer 3 days after initial percutaneous right transhepatic catheter decompression. The stent crossed the ampulla of Vater. Three days later, the stent was balloon-dilated and the percutaneous access was removed. At removal, a small contrast leak from the transhepatic tract was seen. Three days later, pneumoperitoneum was found with symptoms of peritoneal irritation and fever. A widely open sphincter of Oddi caused by the metallic stent, accompanied by delayed sealing of the transhepatic tract, may have causedmore » the air and bile leakage into the peritoneal space. This case shows that pneumoperitoneum may occur without ductal tear or bowel injury, with a biliary stent crossing the ampulla of Vater.« less
The current role of vascular stents.
Busquet, J
1993-09-01
The limitations of percutaneous balloon angioplasty have favoured the development and the use of vascular endoprostheses or stents. These thin-walled metal devices maintain after expansion, an optimal and constant diameter for the vascular lumen. Restenosis, dissection, abrupt closure, residual stenosis or re-opened total occlusion represent appropriate indications for stenting. A large experience with non-coronary application of stents is currently available in iliac, femoro-popliteal and renal arteries, aorta, large veins.
Use of the Palmaz stent in the treatment of severe tracheomalacia.
Geller, Kenneth A; Wells, Winfield J; Koempel, Jeffrey A; St John, Maie A R
2004-08-01
To present our experience with the use of the Palmaz stent in treating cases of severe, life-threatening tracheomalacia, and to report our experience with the use of tracheal stents in patients who have concomitant tracheotomies, we performed a retrospective study in a tertiary-care children's hospital. Nine patients with multiple congenital anomalies including severe tracheomalacia required placement of a Palmaz stent to prolong life. The congenital anomalies included congenital heart disease, congenital lung disease, meningomyelocele, laryngotracheoesophageal cleft, and tracheoesophageal fistula. Three of the patients had concomitant tracheotomies. Each patient had placement of one or more Palmaz stents in the trachea and/or bronchus. Four patients died, and 5 patients are still alive. Three of the 4 patients who died had concomitant tracheotomies and died of complications associated with significant tracheal hemorrhage. The fourth died of pulmonary complications following repeated episodes of pneumonia. None of the 5 patients who are still alive had a concomitant tracheotomy. The Palmaz stent is a useful tool for treating life-threatening tracheomalacia as a final resort in this difficult patient population; however, the use of these stents may lead to subsequent hemorrhage and death, especially in patients with tracheotomies, so their use must be carefully considered.
Lynch, Mark F; Ghani, Khurshid R; Frost, Ian; Anson, Ken M
2007-09-01
To describe and analyze a unique computerized system that tracks ureteral stents and automatically sends a notice by e-mail to clinical staff if a stent becomes overdue for removal. We have developed an electronic stent register (ESR) and stent extraction reminder facility (SERF) located within our hospital computer network. After stent insertion, a stent "episode" is created in the ESR with a mandatory maximal stent life (MSL). The SERF interrogates the ESR on a daily basis and identifies stents that have breached its MSL, generating daily e-mail notices to personnel until the stent is removed and the ESR updated. The episode data capture initially employing manual entry was changed to barcode technology acquisition. We analyzed the success of patient recall and conducted a prospective, blinded review to determine the success of the data acquisition. A total of 293 episodes were created within 2.4 years. Of the 241 (86%) episodes that were closed, 123 (51%) went beyond the MSL. The mean delay from designated MSL to stent removal was 20.89 days (SD 19.71). In the 7 months before barcode data acquisition, 43 of 71 stents were entered into the ESR (data capture rate 61%). In the 7 months after barcode data acquisition, 52 of 60 stents were entered (data capture rate 87%; P = 0.0009). The results of our study have shown the ESR and SERF to be robust and valuable tools for the treatment of patients with ureteral stents. Barcode acquisition significantly improved the stent insertion capture rate. This system ensures improved patient safety with an element of protection from potential litigation.
Perioperative antiplatelet management in patients with coronary artery stenting.
Tandar, Anwar; Velagapudi, Krishna N; Wilson, Brent D; Boden, William E
2012-04-01
Coronary artery disease is the primary cause of mortality in men and women in the United States. Transcatheter coronary intervention is the mainstay of treatment for patients with acute coronary artery disease presentations and patients with stable disease. Although percutaneous intervention initially only included balloon angioplasty, it now typically involves the placement of intracoronary stents. To overcome the limitations of bare-metal stents, namely in-stent restenosis, stents have been developed that remove pharmaceuticals that reduce neointimal hyperplasia and in-stent restenosis. However, these pharmaceutical agents also delay stent endothelialization, posing a prolonged risk of in situ thrombosis. Placement of an intracoronary stent (eg, bare-metal or drug-eluting stent) requires dual antiplatelet therapy to prevent the potentially life-threatening complication of stent thrombosis. The optimal duration of dual antiplatelet therapy following stent placement is unknown. This article discusses the factors to be considered when deciding when dual antiplatelet therapy can be safely discontinued. Unfortunately, in the hospital setting, this decision to interrupt dual antiplatelet therapy frequently must be made shortly after stent placement because of unanticipated surgical procedures or other unforeseen complications. The decision of when dual antiplatelet therapy can be safely interrupted needs to be individualized for each patient and involves factoring in the type of stent; the location and complexity of the lesion stented; post-stent lesion characteristics; the amount of time since stent placement; and the antiplatelet regimen currently in use, along with its implication for bleeding during the proposed procedure. Having a protocol in place, such as the protocol described in this article, can help guide this decision-making process and avoid confusion and potential error.
Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra
2011-02-01
The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice) trials. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Airway stent complications: the role of follow-up bronchoscopy as a surveillance method
Labaki, Wassim; Yu, Diana H.; Salwen, Benjamin; Gilbert, Christopher; Schneider, Andrea L. C.; Ortiz, Ricardo; Feller-Kopman, David; Arias, Sixto; Yarmus, Lonny
2017-01-01
Background Airway stenting has become an integral part of the therapeutic endoscopic management of obstructive benign and malignant central airway diseases. Despite increased use of airway stents and frequent stent-associated complications, no clear guidelines for surveillance and maintenance exist. This study aim is to elucidate predictive factors associated with development of stent complications, as well as an optimal surveillance period for follow-up bronchoscopy for early detection and possible prevention of stent-associated complications. Methods Retrospective cohort study of all patients who underwent airway stent placements at our institution from April 2010 to December 2013 for benign and malignant airway diseases. Metallic, silicone (straight, Y stent, T-tube) and hybrid stents were included in the study. Stent complications were analyzed at the time of follow-up bronchoscopy performed four to six weeks after initial stent placement or earlier if patients became symptomatic. Results The study included 134 patients of which 147 stents were placed. Follow-up bronchoscopy was performed in 94 patients. Symptomatic status at the time of follow-up bronchoscopy was not associated with stent complications [odds ratio (OR) =1.88; 95% CI: 0.79–4.45; P=0.15]. Patient age, sex, indication for stent placement, and stent location, were not associated with development of complications (all P>0.05). Compared to all other stents, hybrid stents were more likely to migrate (OR =6.60; 95% CI: 2.16–20.2; P=0.001) or obstruct by secretions (OR =2.53; 95% CI: 1.10–5.84; P=0.03). There were no complications associated with surveillance bronchoscopy. Conclusions Surveillance bronchoscopy within 4 to 6 weeks of stent placement may be useful for early detection of complications and their subsequent management, regardless of symptomatic status and indication for stent placement. Prospective multicenter studies are needed to compare optimal surveillance methods and the impact on patient mortality, morbidity and healthcare costs. PMID:29268534
Kono, Kenichi; Terada, Tomoaki
2016-02-01
A closed-cell stent called Enterprise has been used for stent-assisted coil embolization of cerebral aneurysms. The Enterprise stent tends to cause kinks and vessel wall malposition in curved vessels and may cause thromboembolic complications. We evaluated vessel wall apposition of a new closed-cell stent, Enterprise 2, compared with a previous Enterprise stent, using curved vascular silicone models. The Enterprise or Enterprise 2 stent was deployed in curved vascular models with various radii of approximately 5 to 10 mm. Stent deployment was performed 25 times in each stent. A push-pull technique was used to minimize incomplete wall apposition. To evaluate conformity of stents, gaps between a stent and a vessel wall were measured. The gap ratio (gap / a wall diameter) was 15 % ± 17 % (mean ± standard deviation) and 41 % ± 15 % with the Enterprise 2 stent and the Enterprise stent, respectively. Taking gap ratios and radii of vessel curvature into consideration, the Enterprise 2 stent had significantly better wall apposition than the Enterprise stent (p = 0.005). In the same radius of vessel curvature, the Enterprise 2 stent had approximately half of the gap compared with the Enterprise stent. There were no significant differences in vessel straightening effects between the two stents. The Enterprise 2 stent has better wall apposition in curved vessels than the Enterprise stent. The gap between a vessel wall and the Enterprise 2 stent is approximately half that of the Enterprise stent. However, gaps and kinks are still present in curved vessels with a small radius. Caution should be taken for kinks and malposition in acutely curved vessels, such as the siphon of the internal carotid artery.
Lee, Eun Sun; Han, Joon Koo; Baek, Ji-Hyun; Suh, Suk-Won; Joo, Ijin; Yi, Nam-Joon; Lee, Kwang-Woong; Suh, Kyung-Suk
2016-06-01
We aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents. This study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34-68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based on clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29-9.95 years). We assessed treatment success rate and patient and graft survival times. During the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00-9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42-4.25). Percutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.
Endoscopic Stent Placement in the Palliation of Malignant Biliary Obstruction
2011-01-01
Biliary drainage with biliary stent placement is the treatment of choice for palliation in patients with malignant biliary obstruction caused by unresectable neoplasms. In such patients, the endoscopic approach can be initially used with percutaneous radiological intervention. In patients with unresectable malignant distal bile duct obstructions, endoscopic biliary drainage with biliary stent placement has now become the main and least invasive palliative modality, which has been proven to be more effective in >80% of cases with lower morbidity than surgery, and perhaps may provide a survival benefit. In patients with unresectable malignant hilar obstruction, the endoscopic approach for biliary drainage with biliary stent placement has also been considered as the treatment of choice. There is still a lack of clear consensus on the use of covered versus uncovered metal stents in malignant distal bile duct obstructions and plastic versus metal stents and unilateral versus bilateral drainage in malignant hilar obstructions. PMID:22741117
Mechanical design of an intracranial stent for treating cerebral aneurysms.
Shobayashi, Yasuhiro; Tanoue, Tetsuya; Tateshima, Satoshi; Tanishita, Kazuo
2010-11-01
Endovascular treatment of cerebral aneurysms using stents has advanced markedly in recent years. Mechanically, a cerebrovascular stent must be very flexible longitudinally and have low radial stiffness. However, no study has examined the stress distribution and deformation of cerebrovascular stents using the finite element method (FEM) and experiments. Stents can have open- and closed-cell structures, and open-cell stents are used clinically in the cerebrovasculature because of their high flexibility. However, the open-cell structure confers a risk of in-stent stenosis due to protrusion of stent struts into the normal parent artery. Therefore, a flexible stent with a closed-cell structure is required. To design a clinically useful, highly flexible, closed-cell stent, one must examine the mechanical properties of the closed-cell structure. In this study, we investigated the relationship between mesh patterns and the mechanical properties of closed-cell stents. Several mesh patterns were designed and their characteristics were studied using numerical simulation. The results showed that the bending stiffness of a closed-cell stent depends on the geometric configuration of the stent cell. It decreases when the stent cell is stretched in the circumferential direction. Mechanical flexibility equal to an open-cell structure was obtained in a closed-cell structure by varying the geometric configuration of the stent cell. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Minimally invasive glaucoma surgery as primary stand-alone surgery for glaucoma.
Kerr, Nathan M; Wang, Jing; Barton, Keith
2017-05-01
Recently, many new devices and procedures have been developed to lower intraocular pressure in a less invasive and purportedly safer manner than traditional glaucoma surgery. These new devices might encourage an earlier transition to surgery and reduce the long-term commitment to topical glaucoma medications with their associated compliance and intolerance issues. Although often seen as an adjunct to cataract surgery, a growing body of evidence suggests that primary minimally invasive glaucoma surgery may be a viable initial treatment option. New studies have shown that primary ab interno trabeculectomy (Trabectome, NeoMedix Inc., Tustin, CA, USA), trabecular micro-bypass stent insertion (iStent and iStent Inject, Glaukos Corporation, Laguna Hills, CA, USA), canalicular scaffolding (Hydrus, Invantis Inc., Irvine CA, USA), the ab interno gel Implant (XEN, Allergan, Dublin, Ireland) or supraciliary stenting (CyPass Micro-Stent, Alcon, Fort Worth, TX, USA) may lower the lowering intraocular pressure and/or topical medication burden in phakic or pseudophakic patients with glaucoma. This effect seems to last at least 12 months but reliable cost-effectiveness and quality of life indicators have not yet been established by investigator-initiated randomized trials of sufficient size and duration. © 2016 Royal Australian and New Zealand College of Ophthalmologists.
Inatomi, Osamu; Bamba, Shigeki; Shioya, Makoto; Mochizuki, Yosuke; Ban, Hiromitsu; Tsujikawa, Tomoyuki; Saito, Yasuharu; Andoh, Akira; Fujiyama, Yoshihide
2013-02-14
Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy.
Park, Jung Gu; Jung, Gyoo-Sik; Oh, Kyung Seung; Park, Seon-Ja
2010-08-01
We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.
Li, W; Zhai, S; Xu, K; Li, Q; Zhong, H; Li, T; Zhang, Z
2018-06-01
The aim was to evaluate the feasibility and safety of a new unibody branched stent graft for the reconstruction of the canine aortic arch. The unibody branched stent grafts included single branched stent grafts and double branched stent grafts. The main stent graft and branched limbs were sutured together. The branched stent grafts were folded into the introducer system, which consisted of a double channel catheter, a detachable sleeve, and an introducer sheath. The branched stent grafts were introduced and deployed into the aortic arch by the delivery system. Twenty adult mongrel dogs were used for the experiments. Ten dogs were implanted with single branched stent grafts; the other 10 were implanted with double branched stent grafts. The surviving animals were followed up for 3 months. Computed tomography angiography (CTA) was performed to observe the status of the branched stent grafts. All the unibody branched stent grafts were successfully implanted into the canine aortic arches. The technical success rate was 100%. There was no cerebral infarction, paraplegia or incision infection. CTA showed that all the branched stent grafts were patent; there was no endoleak or stent migration. The unibody branched stent graft system could be used to reconstruct the aortic arch. The animal experimental procedures demonstrated the safety and feasibility of the unibody branched stent graft system. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.
Novel biliary self-expanding metal stents: indications and applications.
Blero, Daniel; Huberty, Vincent; Devière, Jacques
2015-03-01
Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.
Biliary sphincteroplasty facilitates retrieval of proximally migrated plastic biliary stent.
Shah, Dharmesh K; Jain, Samit S; Somani, Piyush O; Rathi, Pravin M
2014-01-01
Proximal migration of biliary stents presents a technical challenge for the therapeutic endoscopist. It may require multiple, complicated corrective procedures resulting in significant morbidity to the patients. In this study we evaluated the utility of balloon biliary sphincteroplasty with CRE (Controlled Radial Expansion) Balloon Dilator on retrieval of proximally migrated biliary stents. We identified patients from our ERCP database who presented with proximal migration of biliary stent, between August 2011 and October 2013. Patients in whom the stent could not be retrieved with conventional methods, balloon sphincteroplasty was performed with a 12 mm CRETM Balloon Dilator (Boston Scientific). Stent removal was attempted with extraction balloon or basket thereafter. We identified 28 patients with proximal migration of biliary stents, placed for benign diseases of the common bile duct. Stent removal was successful in 18 patients (64.28%) with help of an extraction balloon or basket. Of the remaining 10 patients, balloon sphincteroplasty was successfully followed by stent removal in eight patients. Balloon biliary sphincteroplasty increases the success rate of retrieving proximally migrated biliary stents. The procedure is safe, technically easy and yields a good success rate in our experience.
Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma
2015-07-01
The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward
PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less
Harjai, Kishore J; Mehta, Rajendra H
2007-10-01
Three recently completed randomized studies of carotid artery stenting (CAS) versus endarterectomy-Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy (SAPPHIRE), Endarterectomy versus Stenting in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S), and Stent-Supported Percutaneous Angioplasty of the Carotid Artery versus Endarterectomy (SPACE)-reached vividly different conclusions about the safety of stenting versus endarterectomy. The methodologies of these studies differed from each other in many respects. In an attempt to explain the disparate results of SAPPHIRE, EVA-3S, and SPACE, this focused review compares and contrasts these studies, with specific reference to inclusion and exclusion criteria, technical considerations, and the experience level of the interventional operators.
Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita
2016-01-01
To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.
Use of a retrievable metallic stent internally coated with silicone to treat airway obstruction.
Kim, Jin Hyoung; Shin, Ji Hoon; Song, Ho-Young; Lee, Se Chul; Kim, Kyung Rae; Park, Jung-Hoon
2008-08-01
The authors hypothesized that internally covered stents can reduce the rates of stent migration or mucous retention. The authors performed this study to report their experience with use of a retrievable metallic stent internally coated with silicone in patients with benign or malignant central airway obstructions. From 2004 to 2007, the authors performed fluoroscopically guided placement of a retrievable metallic stent internally coated with silicone in 26 consecutive patients with benign (n = 5) and malignant (n = 21) central airway obstructions. Stents were woven from a single thread of a 0.2-mm-diameter nitinol wire in a tubular configuration and internally covered with silicone membrane. Stent placement was technically and clinically successful in 93% (25/26) and 85% (22/26) of the patients, respectively. There were eight complications (31%) after stent placement, including tumor overgrowth (n = 2), stent migration (n = 1), symptomatic granulation tissue formation (n = 1), severe pain (n = 1), improper stent location (n = 1), symptomatic sputum retention (n = 1) and esophagobronchial fistula (n = 1). Because of complications, five stents were removed with a retrieval hook under fluoroscopic guidance without difficulty. The median survival period and stent patency were 150.0 days +/- 91.4 and 143.0 days +/- 26.7, respectively. The use of a retrievable metallic stent internally coated with silicone is a safe and effective method for relieving dyspnea, with adequate stent patency in patients with benign or malignant central airway obstructions. This stent design seems to be less prone to migration or mucous retention.
Angiographic and Interventional Management for a Esophagopericardial Fistula
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Keng, E-mail: zjwukeng@hotmail.com; You, Qiong, E-mail: qiong_you@yahoo.cn; He, Song-Jian
2013-06-19
We reported a case of a 78-year-old patient with esophagopericardial fistula who was referred for angiographic and interventional management. Emergent implantation of the esophageal stent could not lengthen or even save the patient’s life. One week later, the patient died of multiple organ failure, which was probably from formation of granulation tissue and stent migration. Therefore, if the inflammatory to the esophagopericardial fistula had been better controlled initially, and the implantation of the esophageal stent delayed, our patient would have survived.
Impact of stent strut design in metallic stents and biodegradable scaffolds.
Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip
2014-12-20
Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Tian, Yigeng; Xia, Mingfeng; Zhang, Shuai; Fu, Zhen; Wen, Qingbin; Liu, Feng; Xu, Zongzhen; Li, Tao; Tian, Hu
2016-01-01
Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs) and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice. AgNP-coated Teflon biliary stents were prepared by chemical oxidation-reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD); animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA), and the composition of sediment was assayed by Fourier-transform infrared (FTIR) spectroscopy. Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5-6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR spectroscopy identified stent sediment components including bilirubin, cholesterol, bile acid, protein, calcium, and other substances. AgNP-coated biliary stents resisted sediment accumulation in this canine model of obstructive jaundice caused by ligation of the CBD.
Tian, Yigeng; Xia, Mingfeng; Zhang, Shuai; Fu, Zhen; Wen, Qingbin; Liu, Feng; Xu, Zongzhen; Li, Tao; Tian, Hu
2016-01-01
Objective Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs) and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice. Methods AgNP-coated Teflon biliary stents were prepared by chemical oxidation–reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD); animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA), and the composition of sediment was assayed by Fourier-transform infrared (FTIR) spectroscopy. Results Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5–6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR spectroscopy identified stent sediment components including bilirubin, cholesterol, bile acid, protein, calcium, and other substances. Conclusion AgNP-coated biliary stents resisted sediment accumulation in this canine model of obstructive jaundice caused by ligation of the CBD. PMID:27217749
Yoon, Jin Young; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee
2013-01-01
When re-intervention is required due to an occluded first colorectal self-expanding metal stent for malignant colorectal obstruction, serious controversies exist regarding whether to use endoscopic re-stenting or surgery. To compare the clinical outcomes in patients who underwent stent re-insertion versus palliative surgery as a second intervention. A total of 115 patients who received either self-expandable metal stent (SEMS) insertion or palliative surgery for treatment of a second occurrence of malignant colorectal obstruction after the first SEMS placement were retrospectively studied between July 2005 and December 2009. The median overall survival (8.2 vs. 15.5 months) and progression-free survival (4.0 vs. 2.7 months) were not significantly different between the stent and surgery groups (p = 0.895 and 0.650, respectively). The median lumen patency in the stent group was 3.4 months and that in the surgery group was 7.9 months (p = 0.003). The immediate complication rate after second stent insertion was 13.9% and late complication rate was observed in 12 of 79 (15.2%) patients. There was no mortality related to the SEMS procedure. The complication and mortality rates associated with palliative surgery were 3.5% (2/57) and 12.3% (7/57), respectively. Although there is no significant difference in the overall survival between stenting and surgery, a secondary stent insertion had a lower mortality rate despite a shorter duration of temporary colorectal decompression compared to that of palliative surgery.
Curve micromachining on the edges of nitinol biliary stent by ultrashort pulses laser
NASA Astrophysics Data System (ADS)
Hung, Chia-Hung; Chang, Fuh-Yu
2017-05-01
In this study, a curve micromaching process on the edges of nitinol biliary stent was proposed by a femtosecond laser system with a galvano-mirror scanner. Furthermore, the outer diameter of nitinol tube was 5.116 mm, its inner diameter was 4.648 mm, and its length was 100 mm. The initial fabricated results of nitinol biliary stent represented that the edges of nitinol biliary stent were steep and squared by femtosecond laser. However, the results also indicated that if the laser movement path was precisely programmed by utilizing the unique characteristic of Gaussian beam of femtosecond laser with aligning the edges of stent, the radius of edges enhanced significantly from 9 μm to 42.5 μm. As a result, the edges of nitinol biliary stent can be successfully fabricated from squared edges to rounded-shaped edges with precise dimension, clean surface morphology, and minimal heat-affected zone remained. Hence, the nitinol biliary stent, after femtosecond laser micromachining, would not need any further post-process to remove heat-affected zone and the squared edges.
Recent Advances in Drug Eluting Stents
Puranik, Amey S.; Dawson, Eileen R.; Peppas, Nicholas A.
2013-01-01
One of the most common medical interventions to reopen an occluded vessel is the implantation of a coronary stent. While this method of treatment is effective initially, restenosis, or the re-narrowing of the artery frequently occurs largely due to neointimal hyperplasia of smooth muscle cells. Drug eluting stents were developed in order to provide local, site-specific, controlled release of drugs that can inhibit neointima formation. By implementing a controlled release delivery system it may be possible to control the time release of the pharmacological factors and thus be able to bypass some of the critical events associated with stent hyperplasia and prevent the need for subsequent intervention. However, since the advent of first-generation drug eluting stents, long-term adverse effects have raised concerns regarding their safety. These limitations in safety and efficacy have triggered considerable research in developing biodegradable stents and more potent drug delivery systems. In this review, we shed light on the current state-of-the-art in drug eluting stents, problems related to them and highlight some of the ongoing research in this area. PMID:23117022
Amin, Parth; Sharafuddin, Mel J; Laurich, Chad; Nicholson, Rachael M; Sun, Raphael C; Roh, Simon; Kresowik, Timothy F; Sharp, William J
2012-02-01
This article presents the case of a 42-year-old man who presented with superior vena cava (SVC) syndrome due to fibrosing mediastinitis with multiple failed attempts at recanalization. We initially treated him with unilateral sharp needle recanalization of the right innominate vein into the SVC stump followed by stenting. Although his symptoms improved immediately, they did not completely resolve. Six months later, he returned with worsening symptoms, and venography revealed in-stent restenosis. The patient requested simultaneous treatment on the left side. The right stent was dilated, and a 3-cm-long occlusion of the left innominate vein was recanalized, again using sharp needle technique, homing into the struts of the right-sided stent. Following fenestration of the stent, a second stent was deployed from the left side into the SVC, and the two Y limbs were sequentially dilated to allow a true bifurcation anatomy (figure). The patient had complete resolution of his symptoms and continues to do well 6 months later. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. Methods Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. Results Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). Conclusions Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy. PMID:23410217
Carotid artery stenting: current and emerging options
Morr, Simon; Lin, Ning; Siddiqui, Adnan H
2014-01-01
Carotid artery stenting technologies are rapidly evolving. Options for endovascular surgeons and interventionists who treat occlusive carotid disease continue to expand. We here present an update and overview of carotid stenting devices. Evidence supporting carotid stenting includes randomized controlled trials that compare endovascular stenting to open surgical endarterectomy. Carotid technologies addressed include the carotid stents themselves as well as adjunct neuroprotective devices. Aspects of stent technology include bare-metal versus covered stents, stent tapering, and free-cell area. Drug-eluting and cutting balloon indications are described. Embolization protection options and new direct carotid access strategies are reviewed. Adjunct technologies, such as intravascular ultrasound imaging and risk stratification algorithms, are discussed. Bare-metal and covered stents provide unique advantages and disadvantages. Stent tapering may allow for a more fitted contour to the caliber decrement between the common carotid and internal carotid arteries but also introduces new technical challenges. Studies regarding free-cell area are conflicting with respect to benefits and associated risk; clinical relevance of associated adverse effects associated with either type is unclear. Embolization protection strategies include distal filter protection and flow reversal. Though flow reversal was initially met with some skepticism, it has gained wider acceptance and may provide the advantage of not crossing the carotid lesion before protection is established. New direct carotid access techniques address difficult anatomy and incorporate sophisticated flow-reversal embolization protection techniques. Carotid stenting is a new and exciting field with rapidly advancing technologies. Embolization protection, low-risk deployment, and lesion assessment and stratification are active areas of research. Ample room remains for further innovations and developments. PMID:25349483
Endotracheal nitinol stents: lessons from the learning curve.
Siegel, Bianca; Bent, John P; Ward, Robert F
2013-04-01
To reflect on lessons learned placing endotracheal nitinol stents in children. Case series with chart review. Tertiary care children's hospital. All children who underwent nitinol cervical tracheal stenting were included. Records were carefully reviewed for intraoperative and postoperative complications, management choices, outcomes, and factors that influenced results. Between 1999 and 2011, 7 children underwent 13 stent placements. Median follow-up was 5 years (range, 1-12 years). Six patients underwent stenting as a salvage procedure following open attempts at airway reconstruction. Four patients remain decannulated with their stent in place (median follow-up 7 years). The fifth patient had his stent removed endoscopically after 50 days because it became apparent that his obstruction was primarily laryngeal. The sixth child had his stent removed via a tracheal fissure after 14 months because of recalcitrant subglottic inflammation at the superior stent border. The seventh patient was decannulated for over 2 years but ultimately required tracheotomy replacement because of stenosis with the stent lumen. Complications included stent migration (23%), restenosis (29%), edema (29%), and granulation (57%). Endotracheal nitinol stents provide a realistic opportunity for decannulation in children for whom other options have failed but should be reserved only as a salvage procedure in severely complicated airways. Our experience has taught valuable lessons about stent indications, sizing, characteristics, and deployment, as well as means to avoid and manage their complications.
ElSheemy, Mohammed S; Shouman, Ahmed M; Shoukry, Ahmed I; ElShenoufy, Ahmed; Aboulela, Waseem; Daw, Kareem; Hussein, Ahmed A; Morsi, Hany A; Badawy, Hesham
2015-03-01
To compare percutaneous nephrostomy (PCN) tube vs JJ ureteric stenting as the initial urinary drainage method in children with obstructive calcular anuria (OCA) and post-renal acute renal failure (ARF) due to bilateral ureteric calculi, to identify the selection criteria for the initial urinary drainage method that will improve urinary drainage, decrease complications and facilitate the subsequent definitive clearance of stones, as this comparison is lacking in the literature. A series of 90 children aged ≤12 years presenting with OCA and ARF due to bilateral ureteric calculi were included from March 2011 to September 2013 at Cairo University Pediatric Hospital in this randomised comparative study. Patients with grade 0-1 hydronephrosis, fever or pyonephrosis were excluded. No patient had any contraindication for either method of drainage. Stable patients (or patients stabilised by dialysis) were randomised (non-blinded, block randomisation, sealed envelope method) into PCN-tube or bilateral JJ-stent groups (45 patients for each group). Initial urinary drainage was performed under general anaesthesia and fluoroscopic guidance. We used 4.8-6 F JJ stents or 6-8 F PCN tubes. The primary outcomes were the safety and efficacy of both groups for the recovery of renal functions. Both groups were compared for operative and imaging times, complications, and the period required for a return to normal serum creatinine levels. The secondary outcomes included the number of subsequent interventions needed for clearance of stones. Additional analysis was done for factors affecting outcome within each group. All presented patients completed the study with intention-to-treat analysis. There was no significant difference between the PCN-tube and JJ-stent groups for the operative and imaging times, period for return to a normal creatinine level and failure of insertion. There were significantly more complications in the PCN-tube group. The stone size (>2 cm) was the only factor affecting the rates of mucosal complications, operative time and failure of insertion in the JJ-stent group. The degree of hydronephrosis significantly affected the operative time for PCN-tube insertion. Grade 2 hydronephrosis was associated with all cases of insertion failure in the PCN-tube group. The total number of subsequent interventions needed to clear stones was significantly higher in the PCN-tube group, especially in patients with bilateral stones destined for chemolytic dissolution (alkalinisation) or extracorporeal shockwave lithotripsy (ESWL). We recommend the use of JJ stents for initial urinary drainage for stones that will be subsequently treated with chemolytic dissolution or ESWL, as this will lower the total number of subsequent interventions needed to clear the stones. This is also true for stones destined for ureteroscopy (URS), as JJ-stent insertion will facilitate subsequent URS due to previous ureteric stenting. Mild hydronephrosis will prolong the operative time for PCN-tube insertion and may increase the incidence of insertion failure. We recommend the use of PCN tube if the stone size is >2 cm, as there was a greater risk of possible iatrogenic ureteric injury during stenting with these larger ureteric stones in addition to prolongation of operative time with an increased incidence of failure. © 2014 The Authors. BJU International © 2014 BJU International.
Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua
2018-01-01
To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.
Current Status of the Application of Intracranial Venous Sinus Stenting
Xu, Kan; Yu, Tiecheng; Yuan, Yongjie; Yu, Jinlu
2015-01-01
The intracranial venous sinus is an important component of vascular disease. Many diseases involve the venous sinus and are accompanied by venous sinus stenosis (VSS), which leads to increased venous pressure and high intracranial pressure. Recent research has focused on stenting as a treatment for VSS related to these diseases. However, a systematic understanding of venous sinus stenting (VS-Stenting) is lacking. Herein, the literature on idiopathic intracranial hypertension (IIH), venous pulsatile tinnitus, sinus thrombosis, high draining venous pressure in dural arteriovenous fistula (AVF) and arteriovenous malformation (AVM), and tumor-caused VSS was reviewed and analyzed to summarize experiences with VS-Stenting as a treatment. The literature review showed that satisfactory therapeutic effects can be achieved through stent angioplasty. Thus, the present study suggests that selective stent release in the venous sinus can effectively treat these diseases and provide new possibilities for treating intracranial vascular disease. PMID:26516306
Nishimura, Junya; Kubo, Naoshi; Lee, Tomohiro; Shinto, Osamu; Sakurai, Katsunobu; Toyokawa, Takahiro; Tanaka, Hiroaki; Muguruma, Kazuya; Shibutani, Masatsune; Yamazoe, Sadaaki; Nagahara, Hisashi; Kimura, Kenjiro; Amano, Ryosuke; Ohtani, Hiroshi; Yashiro, Masakazu; Maeda, Kiyoshi; Ohira, Masaichi; Hirakawa, Kosei
2013-11-01
The patient was a 68-year-old man who complained of hoarseness and dyspnea. Upper gastrointestinal endoscopy revealed a type 3 tumor located in the middle thoracic esophagus at 30 cm from the incisor tooth that involved one-fourth of the circumference of the esophagus. Histopathological examination revealed moderately differentiated squamous cell carcinoma. Chest computed tomography( CT) revealed severe tracheal stenosis due to compression by a metastatic lymph node along the left recurrent laryngeal nerve. The patient was diagnosed as having cT4( 106recL-trachea), N2( 101L, 106recL, 106recR), M0, Stage IVa unresectable esophageal carcinoma. After insertion of a tracheal stent tube( spiral Z stent: diameter, 18 mm; length, 80 mm) to improve dyspnea, combination chemotherapy with 5-fluorouracil( 5-FU) plus nedaplatin was administered. Subsequent CT and endoscopy showed that the main tumor and the metastatic lymph node had significantly reduced in size and that complete response (CR) had been achieved. Thirty months after the initial treatment, the patient showed no sign of disease recurrence, after completion of 19 cycles of chemotherapy. The patient did not experience any severe adverse events. We report a case of a patient with locally advanced squamous cell carcinoma of the esophagus successfully treated with 5-FU/nedaplatin combination chemotherapy following tracheal stent tube placement.
Rath, Pratap Chandra; Reddy, Krupal; Agarwal, Manoj K; Purohit, Bharat V; Deb, Tripti; Reddy, Aleti Mallikarjun
2014-01-01
The capability of OCT to examine the structure of the arterial wall before or after PCI is superior to those of other imaging modalities. Therefore the application of OCT during PCI seems logical and has the potential to enhance our performance during the PCI procedures. OCT was performed in fifty-two patients out of which, 45 patients underwent PCI. Out of these 45 patients, in 25 patients both pre and post PCI OCT assessment was done. In 20 patients only post PCI OCT assessment was done. In seven patients PCI was not done due to nonsignificant obstruction, these seven patients were not included in final analysis. Over all OCT leads to management changes in 65% of the time it was used. Alteration of stent length was done in 56% of the cases when evaluated pre PCI. Alteration of stent diameter was done in 36% cases when evaluated pre PCI. Treatment of malapposition was done in 24% of total cases. Further balloon dilatation for vessel expansion was done in 15% of total cases. In one case left main stenting was done after proximal edge dissection. OCT makes better visualization of plaque, thrombus, stent malapposition, dissection, plaque prolapse and helps in optimization of PCI results. More extensive, long-term studies will be needed to assess the prognostic implications of these findings. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Monitoring the Wall Mechanics During Stent Deployment in a Vessel
Steinert, Brian D.; Zhao, Shijia; Gu, Linxia
2012-01-01
Clinical trials have reported different restenosis rates for various stent designs1. It is speculated that stent-induced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis2-7. This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface8,9. As a mesh stent is deployed into a latex vessel with a random contrasting pattern sprayed or drawn on its outer surface, the surface strain is recorded at every instant of the deformation. The calculated strain distributions can then be used to understand the local lesion response, validate the computational models, and formulate hypotheses for further in vivo study. PMID:22588353
Li, Zilun; Ding, Huanyu; Shan, Zhen; Du, Jianliang; Yao, Chen; Chang, Guangqi; Wang, Shenming
2015-11-01
Symptomatic isolated dissection of the superior mesenteric artery (SIDSMA) represents an extremely rare condition. Although various treatments including conservative treatment, endovascular stenting (ES), and surgical repair are currently available, consensus treatment guideline is absent due to scarce of SIDSMA cases. Thus, we present our experience in the treatment of SIDSMA at our single center.Fourteen cases of SIDSMA were treated with conservative treatment, catheter-directed thrombolysis (CDT), endovascular stenting (ES), or surgical repair at our center between January 2008 and January 2014. Demographics, clinical manifestations, coexisting medical conditions, imaging feature, treatments, and follow-up outcome of these patients were retrospectively collected and analyzed.For 13 patients without peritonitis, conservative treatment was given for 4 to 6 days initially. After the first observation cycle, symptoms and signs were alleviated in 8 patients, and conservative treatments were continued. The remaining 5 patients received technically and clinically successful ES (in 4) or CDT (in 1) due to worsening symptoms and signs during conservative treatment. One patient with peritonitis underwent emergency surgery, with the necrotic small intestine resected. However, the abdominal pain was not alleviated 17 days postoperatively, ES was thus performed and symptoms relieved immediately. Two weeks after ES, a new aneurysm and partial thrombosis in the distal part of the stent were found by computed tomography angiography in this patient. No intestinal infarction or mortality developed during hospitalization. Follow-up was accomplished in 11 cases, ranging from 4 to 74 months (23.5 ± 21.3). Except that one complained with mild abdominal pain, the other 10 achieved complete remission. All patients were free from new aneurysmal formation of SMA and all stents remained patent.For SIDSMA without peritonitis, conservative treatment can be provided with reasonable success rate, while ES may serve as an effective alternative once conservative treatment fails. For SIDSMA with peritonitis, open surgery remains the treatment of choice by resection of necrotic intestine and revasculization.
NASA Astrophysics Data System (ADS)
Widiyanti, Prihartini; Paramadini, Adanti W.; Jabbar, Hajria; Fatimah, Inas; Nisak, Fadila N. K.; Puspitasari, Rahma A.
2016-03-01
Cardiovascular disease is a global disease with high urgency. In the severe case of coronary heart disease while a blockage in the coronary arteries reach 75% or more, the patient required stent implantation. Stents are made of metal which has many limitations that can lead to blood clots and stent incompatibility toward the size of the blood vessels. There is a metal stent replacement solution that made from polymer material which is biocompatible. PLLA also has biocompatibility and good mechanical strength. PLLA stent will be coated with chitosan as a candidate for drug-coated stents which is able to work as a drug carrier. The aim of this study is to know the morphology information and biocompability status of PLLA coating chitosan as candidate of heart stent. Morphological results using SEM showed a smooth surface structure which reinforced clinical standard of stent material. Results of cytotoxicity test by MTT Assay method showed that the result of four samples in this experiment living cells is reached 90% which is non toxic and safe to use in the human body. %). The conclusion of this study is PLLA is polymer has potency to be used as stent material.
Xu, Xuan; Ding, Hui; Liu, Xicheng; Zhu, Bin; Feng, Zhichun
2016-01-01
Objective: The objective of this study was to share our experience in the management of congenital tracheal stenosis (CTS) using self-expanding intraluminal stents in infants. Methods: From January 2010 to August 2012, 31 infants with CTS treated using stents by bronchoscope in pediatric intensive care units (PICUs) were recruited for this study. Results: Among the 31 patients, 17 were male and 14 were female with their ages ranging from 55 days to 22 months. CTS was associated with congenital heart disease (CHD) in 22 patients. There were no immediate stent-related airway complications. A significant and immediate improvement of respiratory obstruction following stent placement in all 31 patients led to successful weaning from the breathing machine and extubation. Granulation tissue formation as a complication was observed in three (9.7%) patients, but all were successfully managed using cryotherapy. During follow up (up to 24 months), stents in 29 infants remained functional. In seven cases, stents were retrieved under bronchoscope (the same day to 10 months), and three cases required stent replacement (each of the three cases had the stent replaced three times). Nine infants died after stenting due to other causes and two infants abandoned treatment. Conclusion: Airway stenting may provide an important therapeutic option in infants with CTS. PMID:27126522
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Eun Sun, E-mail: seraph377@gmail.com; Han, Joon Koo, E-mail: hanjk@snu.ac.kr; Baek, Ji-Hyun, E-mail: 100paper@gmail.com
PurposeWe aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents.Materials and MethodsThis study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34–68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based onmore » clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29–9.95 years). We assessed treatment success rate and patient and graft survival times.ResultsDuring the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00–9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42–4.25).ConclusionsPercutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.« less
Endoscopic management of occluded metal biliary stents: Metal versus 10F plastic stents
Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin
2010-01-01
AIM: To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. METHODS: We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. RESULTS: Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). CONCLUSION: Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS. PMID:21072899
Endoscopic management of occluded metal biliary stents: metal versus 10F plastic stents.
Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin
2010-11-14
To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS.
Ductal recanalization and stenting for late presenters with TGA intact ventricular septum
Kothari, Shyam S; Ramakrishnan, Sivasubramanian; Senguttuvan, Nagendra Boopathy; Gupta, Saurabh Kumar; Bisoi, Akshay K
2011-01-01
Introduction: The ideal management strategy for patients presenting late with transposition of great arteries (TGA), intact ventricular septum (IVS), and regressed left ventricle (LV) is not clear. Primary switch, two-stage switch, and Senning operation are the options. Left ventricular retraining prior to arterial switch by ductal stenting may be effective, but the experience is very limited. Methods: Five of six children aged 3–6 months with TGA-IVS and regressed LV underwent recanalization and transcatheter stenting of ductus arteriosus. The ductal stent was removed during arterial switch surgery. Results: The procedure was successful in 5/6 patients. All the patients had totally occluded ductus and needed recanalization with coronary total occlusion hardware. The ductus was dilated and stented with coronary stents. In all the patients, there was significant luminal narrowing despite adequate stent placement and deployment. Two patients needed reintervention for abrupt closure of the stent. Ductal stenting resulted in left ventricular preparedness within 7–14 days. One patient died of progressive sepsis after 14 days of stenting, even though the LV was prepared. Four patients underwent successful uneventful arterial switch surgery. During surgery, it was observed that the mucosal folds of duct were protruding through the struts of the stent in one patient. Conclusions: Ductal stenting is a good alternative strategy for left ventricular retraining in TGA with regressed LV even in patients with occluded ducts. PMID:21976872
Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Kang, Min Kyoung; Lee, Jongjin; Oh, Se Jin
2013-03-01
To evaluate the clinical efficacy and safety of self-expandable metallic stent (SEMS) placement for malignant oesophageal strictures and their relationship with stent designs. Seven generations of SEMS were used to treat 645 consecutive patients with oesophageal strictures. Logistic regression models were constructed to identify predictive factors associated with complications. Stent placement was technically successful in 641 of 645 patients (99.4%). The clinical success rate was 95.5%. There were 260 (40.3%) complications after stent placement. Due to complications, 68 stents were removed; 66 of 68 stents (97.1%) were removed successfully. Stainless steel (SS) stents (odds ratio [OR] 4.18; 95% confidence interval [CI] 2.10, 8.32) and radiation therapy (RT) before stent placement (OR 4.23; CI 2.02, 8.83) were significantly associated with severe pain. Flared ends (OR 9.63; CI 3.38, 27.43), stricture length <6 cm (OR 2.01; CI 1.13, 3.60), and a stent diameter <18 mm (OR 3.00; CI 1.32, 6.84) were predictive factors of stent migration. Polyurethane membranes were associated with more frequent tumour ingrowth than polytetrafluoroethylene (PTFE) membranes (P = 0.002). Despite the relatively high complication rate, retrievable self-expandable PTFE-covered nitinol stents equipped with a head and a tail appeared to be an effective treatment for malignant oesophageal strictures.
Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming
2015-08-01
To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.
Research of Customized Aortic Stent Graft Manufacture
NASA Astrophysics Data System (ADS)
Zhang, Lei; Chen, Xin; Liu, Muhan
2017-03-01
Thoracic descending aorta diseases include aortic dissection and aortic aneurysm, of which the natural mortality rate is extremely high. At present, endovascular aneurysm repair (EVAR) has been widely used as an effective means for the treatment of descending aortic disease. Most of the existing coating stents are standard design, which are unable to meet the size or structure of different patients. As a result, failure of treatment would be caused by dimensional discrepancy between stent and vessels, which could lead to internal leakage or rupture of blood vessels. Therefore, based on rapid prototyping sacrificial core - coating forming (RPSC-CF), a customized aortic stent graft manufactured technique has been proposed in this study. The aortic stent graft consists of film and metallic stent, so polyether polyurethane (PU) and nickel-titanium (NiTi) shape memory alloy with good biocompatibility were chosen. To minimum film thickness without degrading performance, effect of different dip coating conditions on the thickness of film were studied. To make the NiTi alloy exhibit super-elasticity at body temperature (37°C), influence of different heat treatment conditions on austenite transformation temperature (Af) and mechanical properties were studied. The results show that the customized stent grafts could meet the demand of personalized therapy, and have good performance in blasting pressure and radial support force, laying the foundation for further animal experiment and clinical experiment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Zhongmin, E-mail: wzm0722@hotmail.co; Chen Kemin, E-mail: ckm0722@hotmail.co; Gong Ju
Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival timemore » between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.« less
Disappearing and reappearing differences in drug-eluting stent use by race.
Federspiel, Jerome J; Stearns, Sally C; Reiter, Kristin L; Geissler, Kimberley H; Triplette, Matthew A; D'Arcy, Laura P; Sheridan, Brett C; Rossi, Joseph S
2013-04-01
Drug-eluting coronary stents (DES) rapidly dominated the marketplace in the United States after approval in 2003, but utilization rates were initially lower among African American patients. We assess whether racial differences persisted as DES diffused into practice. Medicare claims data were used to identify coronary stenting procedures among elderly patients with acute coronary syndromes (ACS). Regression models of the choice of DES versus bare mental stent controlled for demographics, ACS type, co-morbidities and hospital characteristics. Diffusion was assessed in the short run (2003-2004) and long run (2007), with the effect of race calculated to allow for time-varying effects. The sample included 381,887 Medicare beneficiaries treated with stent insertion; approximately 5% were African American. Initially (May 2003-February 2004), African American race was associated with lower DES use compared to other races (44.3% versus 46.5%, P < 0.01). Once DES usage was high in all patients (March-December 2004), differences were not significant (79.8% versus 80.3%, P = 0.45). Subsequent concerns regarding DES safety caused reductions in DES use, with African Americans having lower use than other racial groups in 2007 (63.1% versus 65.2%, P < 0.01). Racial disparities in DES use initially disappeared during a period of rapid diffusion and high usage rates; the reappearance of disparities in use by 2007 may reflect DES use tailored to unmeasured aspects of case mix and socio-economic status. Further work is needed to understand whether underlying differences in race reflect decisions regarding treatment appropriateness. © 2011 Blackwell Publishing Ltd.
Heating of cardiovascular stents in intense radiofrequency magnetic fields.
Foster, K R; Goldberg, R; Bonsignore, C
1999-01-01
We consider the heating of a metal stent in an alternating magnetic field from an induction heating furnace. An approximate theoretical analysis is conducted to estimate the magnetic field strength needed to produce substantial temperature increases. Experiments of stent heating in industrial furnaces are reported, which confirm the model. The results show that magnetic fields inside inductance furnaces are capable of significantly heating stents. However, the fields fall off very quickly with distance and in most locations outside the heating coil, field levels are far too small to produce significant heating. The ANSI/IEEE C95.1-1992 limits for human exposure to alternating magnetic fields provide adequate protection against potential excessive heating of the stents.
[Paliative managment of oesophageal carcinomas--our experience].
Polanecký, O; Pazdro, A; Tvrdon, J; Tersíp, T; Smejkal, P; Smejkal, M; Hladík, P; Pafko, P
2006-04-01
The authors of this presentation explain their experience with methods of paliative care of oesophagus carcinoma. The indication criteria are described and compared advantages and disadvantages of those methods. There is an accent in most frequent method--oesophagus stent implementation. The results in the group of patients after the stent implementation are described, also complications and other solutions.
Law, Ryan; Baron, Todd H
2013-09-01
Controversy exists on optimal endoscopic management for palliation of malignant hilar obstruction, with advocates for metal "side-by-side" (SBS) and "stent-in-stent" (SIS) techniques. We sought to evaluate the technical feasibility, efficacy, and outcomes of bilateral biliary self-expanding metal stents (SEMS) for treatment of malignant hilar obstruction using a stent with a 6Fr delivery system. This was a single-center, retrospective review of all patients who underwent bilateral placement of Zilver® biliary SEMS for malignant hilar obstruction from January 2010 to August 2012. Patients underwent endoscopic retrograde cholangiopancreatography with placement of stents using either the SIS or SBS stent techniques. Twenty-four patients (19 men, mean age 63 years) underwent bilateral stenting for malignant hilar obstruction during the study period. Seventeen and seven patients underwent the SBS and SIS technique, respectively. Cholangiocarcinoma (n=14) was the most common cause of hilar obstruction. Initial technical success was achieved in 24/24 (100%) of patients; however, 12 (50%) patients required re-intervention during the study period (median 98 days). Comparison of the SBS and SIS groups revealed no statistical difference with respect to need for re-intervention (P=0.31), successful re-intervention (P=0.60), or procedural length (P=0.89). Use of bilateral Zilver® SEMS in either the SBS or SIS configuration is safe, technically feasible, and effective for drainage of malignant hilar obstruction; however, duration of stent patency and procedure-free survival remain variable.
Endoscopic stenting for benign upper gastrointestinal strictures and leaks.
Sharaiha, Reem Z; Kim, Katherine J; Singh, Vikesh K; Lennon, Anne Marie; Amateau, Stuart K; Shin, Eun Ji; Canto, Marcia Irene; Kalloo, Anthony N; Khashab, Mouen A
2014-01-01
Self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) maybe used for the treatment of benign upper gastrointestinal (GI) leaks and strictures. This study reviewed our experience with stent insertions in patients with benign upper GI conditions. Patients who underwent stent placement for benign upper GI strictures and leaks between March 2007 and April 2011 at a tertiary referral academic center were studied using an endoscopic database and electronic patient records. The technical success, complications, and clinical improvement after stent removal were compared according to type of stent. The outcomes measured were clinical response, adverse events, and predictors of stent migration. Thirty-eight patients (50 % male, mean age = 54 years, range = 12-82) underwent 121 endoscopic procedures. Twenty patients had stents placed for strictures, and 18 had stents placed for leaks. Stent placement was technically successful in all patients. The average duration of stent placement was 54 days (range = 18-118). Clinical improvement immediately after stent placement was seen in 29 of the 38 patients (76.3 %). Immediate post-procedure adverse events occurred in 8 patients. Late adverse events were seen in 18 patients. Evidence of stent migration occurred in 16 patients and was seen in 42 of the 118 successfully placed stents (35.5 %). Migration was more frequent with fully covered SEMS (p = 0.002). After stent removal, 27 patients were evaluable for long-term success (median follow-up time of 283 days, IQR 38-762). Resolution of strictures or leaks was seen in 11 patients (40.7 %). Predictors for long-term success included increasing age and if the stent did not cross the GE junction. Placement of SEPS and SEMS for benign refractory strictures and fistulas has modest long-term clinical efficacy and is limited by a significant migration rate. Stent migration is common and frequent with fully covered SEMS compared to other types of stents, regardless of indication or location.
Jang, Sung Ill; Lee, Se Joon; Jeong, Seok; Lee, Don Haeng; Kim, Myung-Hwan; Yoon, Hong Jin; Lee, Dong Ki
2017-07-15
A drug-eluting stent for unresectable malignant biliary obstruction was developed to increase stent patency by preventing tumor ingrowth. The safety and efficacy of a new generation of metallic stents covered with a paclitaxel-incorporated membrane using a Pluronic ® mixture (MSCPM-II) were compared prospectively with those of covered metal stents (CMSs) in patients with malignant biliary obstructions. This study was initially designed as a prospective randomized trial but was closed early because of a high incidence of early occlusion. Therefore, the data were analyzed using the intent-to-treat method. A total of 72 patients with unresectable distal malignant biliary obstructions were prospectively enrolled. The two groups did not differ significantly in basic characteristics and mean follow-up period (MSCPM-II 194 days vs CMS 277 days, p=0.063). Stent occlusion occurred in 14 patients (35%) who received MSCPM-II and in seven patients (21.9%) who received CMSs. Stent patency and survival time did not significantly differ between the two groups (p=0.355 and p=0.570). The complications were mild and resolved by conservative management in both groups. There were no significant differences in stent patency or patient survival in MSCPM-II and CMS patients with malignant biliary obstructions.
Metallic Full-Length Ureteral Stents: Does Urinary Tract Infection Cause Obstruction?
Brown, James A.; Powell, Christopher L.; Carlson, Kristopher R.
2010-01-01
Metallic ureteral stents promise to offer superior upper urinary tract drainage with extended exchange intervals and freedom from extrinsic compression in patients with advanced malignancy or other significant obstructing retroperitoneal or pelvic processes. Existing literature indicates a variable experience with these relatively new devices, with some investigators reporting excellent results and long problem-free intervals, and others reporting less enthusiastic outcomes. We report a retrospective review of a series of five sequential patients undergoing placement of Resonance® (Cook Medical, Bloomington, IN) metallic ureteral stents for extrinsic ureteral compression refractory to placement of traditional (polymer) ureteral stents. Of five patients reviewed, three (60%) required additional operative intervention for stent migration or malposition. Four patients (80%) died of their primary malignancy <12 months after metallic stent placement. Four (80%) of five patients had obstruction of their stents demonstrated with nuclear renography and/or other imaging, and three (60%) required removal and alternative means of urinary tract drainage within 4 months of placement due to obstruction, intractable pain, or migration. Four patients (80%) had urinary tract infections (UTIs) within 4 months of stent placement. No obstruction was seen due to extrinsic ureteral compression after stent placement. Metallic ureteral stents may have utility for patients with pathological processes causing extrinsic ureteral compression refractory to the use of traditional polymer ureteral stents. However, metallic ureteral stents are not immune to obstruction, migration, and associated discomfort. Stent obstruction appears to be increased in patients with postoperative UTI. PMID:20730376
Metallic full-length ureteral stents: does urinary tract infection cause obstruction?
Brown, James A; Powell, Christopher L; Carlson, Kristopher R
2010-08-17
Metallic ureteral stents promise to offer superior upper urinary tract drainage with extended exchange intervals and freedom from extrinsic compression in patients with advanced malignancy or other significant obstructing retroperitoneal or pelvic processes. Existing literature indicates a variable experience with these relatively new devices, with some investigators reporting excellent results and long problem-free intervals, and others reporting less enthusiastic outcomes. We report a retrospective review of a series of five sequential patients undergoing placement of Resonance (Cook Medical, Bloomington, IN) metallic ureteral stents for extrinsic ureteral compression refractory to placement of traditional (polymer) ureteral stents. Of five patients reviewed, three (60%) required additional operative intervention for stent migration or malposition. Four patients (80%) died of their primary malignancy <12 months after metallic stent placement. Four (80%) of five patients had obstruction of their stents demonstrated with nuclear renography and/or other imaging, and three (60%) required removal and alternative means of urinary tract drainage within 4 months of placement due to obstruction, intractable pain, or migration. Four patients (80%) had urinary tract infections (UTIs) within 4 months of stent placement. No obstruction was seen due to extrinsic ureteral compression after stent placement. Metallic ureteral stents may have utility for patients with pathological processes causing extrinsic ureteral compression refractory to the use of traditional polymer ureteral stents. However, metallic ureteral stents are not immune to obstruction, migration, and associated discomfort. Stent obstruction appears to be increased in patients with postoperative UTI.
Wu, Xue; Yin, Tieying; Tian, Jie; Tang, Chaojun; Huang, Junli; Zhao, Yinping; Zhang, Xiaojuan; Deng, Xiaoyan; Fan, Yubo; Yu, Donghong; Wang, Guixue
2015-01-01
It is not clear what effects of CD34- and CD133-specific antibody-coated stents have on re-endothelialization and in-stent restenosis (ISR) at the early phase of vascular injury. This study aims at determining the capabilities of different coatings on stents (e.g. gelatin, anti-CD133 and anti-CD34 antibodies) to promote adhesion and proliferation of endothelial progenitor cells (EPCs). The in vitro study revealed that the adhesion force enabled the EPCs coated on glass slides to withstand flow-induced shear stress, so that allowing for the growth of the cells on the slides for 48 h. The in vivo experiment using a rabbit model in which the coated stents with different substrates were implanted showed that anti-CD34 and anti-CD133 antibody-coated stents markedly reduced the intima area and restenosis than bare mental stents (BMS) and gelatin-coated stents. Compared with the anti-CD34 antibody-coated stents, the time of cells adhesion was longer and earlier present in the anti-CD133 antibody-coated stents and anti-CD133 antibody-coated stents have superiority in re-endothelialization and inhibition of ISR. In conclusion, this study demonstrated that anti-CD133 antibody as a stent coating for capturing EPCs is better than anti-CD34 antibody in promoting endothelialization and reducing ISR. PMID:26813006
Mydlo, J H; Streater, S
2001-01-01
There have been many reports describing the complications of retained ureteral stents following stone treatment. We wanted to evaluate the practicality of definitive treatment of poorly compliant patients who present with ureteral stones using a straight stent connected to a urethral catheter alone and compared these to patients treated with double-J stents alone. We treated 23 patients (12 in group I and 11 patients in group II) who had a ureteral stone of 6 mm or less, with an indwelling straight stent and a double-J stent, respectively, while on oral antibiotics. We followed these patients 1 week later with an abdominal X-ray prior to removing the stent. Eleven patients in group I and 9 patients in group II passed their stones spontaneously. Three patients required surgical intervention with a ureterscope and laser lithotripsy. There were no cases of infection or pyelonephritis. Although each of the straight-stent-treated patients returned to our clinic for follow-up, only 5 of the 11 double-J stent patients returned for follow-up. The remaining 6 patients had to be contacted to remind them that they still had an internal stent. Although technologic advances now allow many urologists to definitively treat ureteral stones, some urologists may lack the proper equipment and/or assistance to treat the stone at the time of presentation, or may deal with non-compliant patients. Therefore, in these certain circumstances, treatment of small ureteral stones in non-compliant patients using a straight stent connected to a leg bag, as either definitive or initial treatment, may be of practical use and avoid the risk of retained double-J ureteral stents. Copyright 2001 S. Karger AG, Basel
Kitahara, Takahiro; Hatano, Taketo; Hayase, Makoto; Hattori, Etsuko; Miyakoshi, Akinori; Nakamura, Takehiko
2017-04-01
The horizontal stenting technique facilitates endovascular treatment of wide-necked bifurcation intracranial aneurysms. Previous literature shows, however, that subsequent coil embolization at initial treatment results in incomplete obliteration in many cases. The authors present two consecutive cases of wide-necked large bifurcation aneurysms to describe an additional coil embolization technique following horizontal stenting. The patients were a 53-year-old female with an unruptured internal carotid artery terminus aneurysm and a 57-year-old female with a recurrent basilar artery tip aneurysm. Both patients underwent endovascular treatment with horizontal stenting followed by coil embolization with jailed double-microcatheters. Immediate complete obliteration was achieved with no complications, and no recanalization was observed at the one-year follow-up in both cases. Coil embolization with jailed double-microcatheter technique following horizontal stenting is a safe and effective strategy for wide-necked bifurcation aneurysms.
A new thermal shape memory Ti-Ni alloy stent covered with silicone.
Nakamura, T; Shimizu, Y; Ito, Y; Matsui, T; Okumura, N; Takimoto, Y; Ariyasu, T; Kiyotani, T
1992-01-01
An attempt was made to develop an airway stent for nonsurgical transluminal implantation using a bronchofiberscope. The stent is composed of a single wire with a diameter of 0.5 mm. The wire is made of thermal shape memory titanium nickel alloy, with a transition temperature of 25-30 degrees C. To avoid direct contact between the metal and the tissue, the wire is covered with a 300 microns thick coating of silicone. The stent is horseshoe shaped in cross-section. It is 15 mm in outer transverse diameter and 40 mm long. Ten stents were implanted in 10 dogs whose tracheal cartilages had been previously broken. The stents were first cooled in ice water to reduce their diameter and then inserted into the target site. The wire was warmed to body temperature and recovered its initial shape within 10 sec. The dogs were killed for examination between 1 week and 6 months after implantation. All the stents were located at the implantation sites and were patent. Tissue reactions, such as ulceration and granulation formation, were less severe than in those with previously implanted non-silicone covered stents. Microscopic observation showed that the wires became gradually covered with epithelium within 2 months. This transluminal technique for preserving airway patency shows promise for clinical application.
Rieger, Johannes; Hautmann, Hubert; Linsenmaier, Ulrich; Weber, Cristoph; Treitl, Markus; Huber, Rudolf Maria; Pfeifer, Klaus-Jürgen
2004-01-01
Over the last few years various types of metal wire stents have been increasingly employed in the treatment of both malignant and benign tracheobronchial obstruction. To date, however, few studies have investigated the in vivo properties of different stent types. We implanted 26 balloon-expandable tantalum Strecker stents (18 patients) and 18 self-expandable Wallstents (16 patients) into the tracheobronchial system of 30 patients with combined stenting in 4 patients. Mean age was 51 years (range: 0.5-79 years). Malignant disease was present in 23 patients, benign disease in seven patients. Both patients and individual stents were monitored clinically and radiographically. The probability of stents remaining within the tracheobronchial system, and of their remaining undislocated and uncompressed was calculated using Kaplan-Meier analysis for both stent types. Average stent follow-up time was 112 days until explantation and 115 days until patients' death or discharge. Kaplan-Meier analysis revealed a higher probability for the Wallstent to remain within the tracheobronchial system. Dislocation and compression occurred more rarely. Explantation, however, if desired, was more difficult compared to the Strecker stent. The Wallstent also led to the formation of granulation tissue, especially at the proximal stent end, frequently requiring reintervention. Both stent types proved to be effective therapeutic options in the management of obstructive tracheobronchial disease. The mechanical properties of the Strecker stent seem to be less favorable compared to the Wallstent but removal is easy. For benign disease, however, the Wallstent reveals limitations due to significant side effects.
Covered Balloon-Expanding Stents in Airway Stenosis.
Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik
2017-04-01
The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (P<0.05). Self-reported respiratory symptoms improved in 14 patients (78%, P<0.05). Radiographic improvement post Atrium iCAST stent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.
Senousy, Bahaa E; Gupte, Anand R; Draganov, Peter V; Forsmark, Chris E; Wagh, Mihir S
2010-12-01
Expandable esophageal stents are widely used for the palliation of dysphagia in patients with esophageal cancer and are also beginning to be used in patients with benign esophageal diseases such as refractory strictures and fistulas. There is concern regarding the increased risk of migration of the fully covered Alimaxx metal esophageal stent and experience with this stent in benign esophageal pathology has been reported in only a small series of patients. To evaluate the technical success in placement and removal, efficacy and complications of the Alimaxx esophageal stent for benign esophageal diseases. Our endoscopy database was retrospectively reviewed from 1/2003 to 2/2009 to identify patients with Alimaxx esophageal stent placement for benign diseases. Chart review was performed for age, gender, indication, site of the lesion, success of placement, outcome, and incidence of complications. Twenty-eight stents were successfully placed in 14 patients with benign esophageal diseases (mean: two stents/patient; range 1-7). Indications included esophageal fistula in seven (50%) and benign strictures in 7/14 (50%). Dysphagia improved in all patients while the fistula resolved in 6/7 (85.8%) patients. Complications related to stents included pain (2/28, 7%), stent related gastric ulcer (1/28, 4%), nausea and vomiting (3/21, 11%) and stent migration (11/28, 39%). All migrated stents were successfully endoscopically retrieved. The fully covered and removable Alimaxx stent is effective in the endoscopic management of benign esophageal strictures or fistulas, despite its relatively high rate of migration. Stent migration was successfully managed endoscopically without complications.
Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka
2018-06-01
We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.
Role of Animal Models in Coronary Stenting.
Iqbal, Javaid; Chamberlain, Janet; Francis, Sheila E; Gunn, Julian
2016-02-01
Coronary angioplasty initially employed balloon dilatation only. This technique revolutionized the treatment of coronary artery disease, although outcomes were compromised by acute vessel closure, late constrictive remodeling, and restenosis due to neointimal proliferation. These processes were studied in animal models, which contributed to understanding the biology of endovascular arterial injury. Coronary stents overcome acute recoil, with improvements in the design and metallurgy since then, leading to the development of drug-eluting stents and bioresorbable scaffolds. These devices now undergo computer modeling and benchtop and animal testing before evaluation in clinical trials. Animal models, including rabbit, sheep, dog and pig are available, all with individual benefits and limitations. In smaller mammals, such as mouse and rabbit, the target for stenting is generally the aorta; whereas in larger animals, such as the pig, it is generally the coronary artery. The pig coronary stenting model is a gold-standard for evaluating safety; but insights into biomechanical properties, the biology of stenting, and efficacy in controlling neointimal proliferation can also be gained. Intra-coronary imaging modalities such as intravascular ultrasound and optical coherence tomography allow precise serial evaluation in vivo, and recent developments in genetically modified animal models of atherosclerosis provide realistic test beds for future stents and scaffolds.
Heiferman, Daniel M; Billingsley, Joshua T; Kasliwal, Manish K; Johnson, Andrew K; Keigher, Kiffon M; Frudit, Michel E; Moftakhar, Roham; Lopes, Demetrius K
2016-07-01
Flow-diverting stents, including the Pipeline embolization device (PED) and Silk, have been beneficial in the treatment of aneurysms previously unable to be approached via endovascular techniques. Recurrent aneurysms for which stent-assisted embolization has failed are a therapeutic challenge, given the existing intraluminal construct with continued blood flow into the aneurysm. We report our experience using flow-diverting stents in the repair of 25 aneurysms for which stent-assisted embolization had failed. Nineteen (76%) of these aneurysms at the 12-month follow-up showed improved Raymond class occlusion, with 38% being completely occluded, and all aneurysms demonstrated decreased filling. One patient developed a moderate permanent neurologic deficit. Appropriate stent sizing, proximal and distal construct coverage, and preventing flow diverter deployment between the previously deployed stent struts are important considerations to ensure wall apposition and prevention of endoleak. Flow diverters are shown to be a reasonable option for treating previously stented recurrent cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
French experience of silicone tracheobronchial stenting in children.
Fayon, Michael; Donato, Lionel; de Blic, Jacques; Labbé, André; Becmeur, François; Mely, Laurent; Dutau, Hervé
2005-01-01
Silicone stents were inserted into the trachea or left main-stem bronchus in 14 children aged 2-69 months (median, 7 months). Indications were as follows: tracheomalacia or airway kinking (7 cases), vascular compression (5 cases), and surgically corrected congenital tracheal stenoses (2 cases). The best results were obtained in tracheomalacia. Overall, 6 cases out of 14 (43%) were considered successful, with a stent placement duration of 3-15 months (median, 7 months). Two cases were considered a technical success, although they were clinical failures. Five cases were considered failures primarily due to stent migration. A retrospective analysis of failures suggests that most of these could have been avoided by the use of larger stents. One patient died of stent obstruction. No wall erosion was observed, and the development of granulation tissue was infrequent. Endoscopic removal of the prostheses was uneventful. The biocompatibility of silicone stents appears to be better than what is reported for metal ones, although the stability of the former is less satisfactory. The present study shows the feasibility of silicone stent placement in infants. These stents should be considered as a possible therapeutic option in certain types of childhood airway disorders, although further studies are required.
Vlavianos, Panagiotis; Zabron, Abigail
2012-03-01
This review will discuss the immediate- and long-term success, complications and overall benefits of self-expandable metal stents (SEMSs) in malignant or benign obstruction of the oesophagus, stomach and duodenum. Over recent years, indications such as benign disease have expanded, as has SEMS diversity with self-expandable plastic stents (SEPSs) or fully covered and biodegradable stents, for example. SEMSs have been increasingly used in malignant upper gastrointestinal obstruction with many reports confirming efficacy, despite a significant complication rate. Fully covered stents are increasingly used for a variety of benign oesophageal disease, but their place in gastric outlet obstruction is still unclear. Covered and uncovered stents have different functional characteristics and stent type must be selected on an individual basis. Biodegradable stents show promise and the outcome of experience in larger patient cohorts is eagerly awaited. This area is an evolving field, in which the clinician requires up-to-date knowledge of therapeutic options to make individualized treatment choices in difficult clinical circumstances. Technical and clinical success for oesophageal or gastroduodenal SEMSs are then above 90%. Minor complications are common, but serious complications seldom occur. Biodegradable stents may be useful, especially when stenting is needed for a short period of time.
García Carrascal, P; García García, J; Sierra Pallares, J; Castro Ruiz, F; Manuel Martín, F J
2017-05-01
Stent implantation is a common procedure followed in arteries affected by atherosclerosis. This procedure can lead to other stenting-related problems. One of these is the deposition and accumulation of blood clots over stent struts. This process can have further consequences, in so far as it can introduce modifications to the flow pattern. This problem is especially critical in stented bifurcations, where resulting stent geometry is more complex. In this regard, a numerical study is presented of the effect on the flow pattern and platelet activation of blood clot depositions on the stent struts of a stented coronary bifurcation. The numerical model is first validated with experimental measurements performed for this purpose. Experiments considered a flow with suspended artificial thrombi, which naturally deposited on stent struts. The location and shape observed were used to create numerical thrombi. Following this, numerical simulations were performed to analyze the influence of the presence of thrombi depositions on parameters such as Time Averaged Wall Shear Stress, Oscillatory Shear Index or Relative Residence Time. Finally, a study was also carried out of the effect of different geometrical configurations, from a straight tube to a stented bifurcation model with thrombus depositions, on platelet activation.
[Successful correction with stent-graft of coronary artery rupture after angioplasty].
Demin, V V
2003-01-01
Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.
Gelbmann, C M; Ratiu, N L; Rath, H C; Rogler, G; Lock, G; Schölmerich, J; Kullmann, F
2004-08-01
Extensive anastomotic leaks after esophageal resection and esophageal perforations are a therapeutic challenge. The aim of the present study was to assess the potential of the self-expandable Polyflex plastic stent for the treatment of these conditions. Between January 2002 and March 2003, nine patients were treated with a self-expandable Polyflex plastic stent for sealing of thoracic esophagoenteric anastomotic leaks following surgical resection (n = 5) or esophageal perforation (n = 4). In all patients the stents were inserted successfully without technical problems. In all but two patients complete sealing of the leak was achieved as demonstrated by radiography with water-soluble contrast media. The stent migration rate was 30 % and repositioning of the migrated stents was possible in all cases. Complete mucosal healing of the esophageal leaks and stent extraction was achieved in six patients. The stents were in situ for an average period of 135 +/- 78 days. Two critically ill patients with anastomotic leaks died in spite of stent insertion due to sepsis and one patient with esophageal perforation died due to the underlying malignant disease. Our preliminary experience with the self-expanding and removable Polyflex plastic stent for the sealing of anastomotic leaks and esophageal perforations suggests that this stent is a feasible treatment option, in particular, for more extensive esophageal defects, patients with co-morbid conditions, and critically ill patients.
Covered Stent Grafts for Acquired Arterial Venous Fistulas: A Case Series.
Sarac, Timur P; Vargas, Lina; Kashyap, Vikram; Cardella, Jonathan; Chaar, Cassius Ochoa
2018-01-01
Stent grafts have become the preferred method for treating abdominal aortic aneurysms (AAAs) but also have utility in treating other vasculopathies. In 2005, peripheral stent grafts were approved for treating superficial femoral artery occlusive disease. This report describes our experience using covered stent grafts to treat acquired arterial venous fistulae (aAVF). We reviewed the records of patients treated for aAVF with covered stent grafts. Eleven patients had 12 limbs treated with a stent graft. The data collected included presenting symptoms, mechanism of injury, vessel location, stent graft used for therapy, and patency. Eleven patients underwent successful treatment of 12 aAVF with a peripheral stent grafts. The average age was 55.6 (18-87), and there were 4 women and 7 men. The mechanisms of injuries were heart catheterization in 5 patients, penetrating trauma in 3 patients, and orthopedic injury in 3 patients. Five of the patients had concurrent pseudoaneurysms. Self-expanding expanded polytetrafluoroethelene (ePTFE) stent grafts were used in 8 patients, and balloon-expandable ePTFE stent grafts were used in 3 patients. Primary patency at 2 years is 100%, with all patients having significant relief of symptoms. Peripheral stent grafts are a useful tool for treating aAVF, with excellent patency. They provide a valuable minimally invasive approach to this disease. Copyright © 2017 Elsevier Inc. All rights reserved.
Madden, Brendan P; Park, John E S; Sheth, Abhijat
2004-12-01
Between March 1997 and March 2004 we deployed 80 Ultraflex metallic expandable stents (Boston Scientific, Waterson, MA) in 69 patients under direct vision using rigid bronchoscopy. We report our medium- to long-term experience in patients for whom these stents were deployed. To date 15 patients have been followed for more than 1 year (median 41 months, range 12 to 83 months) after stent deployment. Indications for stenting in these patients were neoplasia (5), stricture (5), airway malacia (1), iatrogenic tracheal tear (1), and compression from an aortic aneurysm (1), a right interrupted aortic arch (1), and a right brachiocephalic artery aneurysm with tracheomalacia (1). Ten tracheal stents (9 covered, 1 uncovered) and 10 bronchial stents (8 uncovered, 2 covered) were inserted, and 5 patients received two stents. Five of these patients experienced no long-term problems. Complications included troublesome halitosis (5), which was difficult to treat despite various antibiotic regimes; granulation tissue formation above and below the stent that was successfully treated with low-power Nd:YAG laser therapy (7); and metal fatigue (1). We did not encounter stent migration. We conclude that Ultraflex expandable metallic stents have an important role in the management of selected patients with diverse endobronchial pathologies and are well tolerated in the long-term. Although associated granulation tissue can be successfully treated with Nd:YAG laser, halitosis can be a difficult problem to address.
Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan
2015-10-01
Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.
Nitinol stents in the treatment of benign proximal tracheal stenosis or tracheomalacia.
Isa, A Y; Macandie, C; Irvine, B W
2006-01-01
Nitinol stents have been used in the treatment of benign tracheal stenosis. A retrospective review of five patients treated at Stobhill Hospital over the last six and a half years is presented. Age at presentation ranged from 17 to 76 years. The minimum follow-up period was 23 months and the maximum was 78 months. All our patients were successfully decannulated, with none requiring recannulation. Four patients developed granulation tissue related to the stent at intervals ranging from three weeks to 41 months post stenting. Topical mitomycin C application has been useful after resection of granulations using the carbon dioxide (CO2) laser. Stent migration occurred in one patient three weeks after insertion. Nitinol stents are easy to insert and effective in the treatment of tracheal stenosis, but can have associated morbidity. Their use should be considered carefully, as insertion should be regarded as permanent. Publications reporting experience and outcome with the use of Nitinol stents in the trachea are reviewed.
Role of metallic stents in benign esophageal stricture
NASA Astrophysics Data System (ADS)
Shim, Chan Sup
2012-10-01
Simple esophageal strictures, which are focal, straight, and large in diameter, usually require 1 - 3 dilation sessions to relieve symptoms. However, complex strictures, which are long, tortuous, or associated with a severely compromised luminal diameter, are usually more difficult to treat with conventional bougie or balloon dilation techniques, and often have high recurrence rates. Although the permanent placement of self-expandable metal stents (SEMS) has been used to manage refractory benign esophageal strictures, this procedure is associated with additional problems, such as stricture from tissue hyperplasia, stent migration, and fistula formation. Thus, several new types of stents have been developed, including temporary SEMS, self-expandable plastic stents (SEPS), and biodegradable stents. The use of these new products has produced varied results. Temporary SEMS that have been used to relieve benign esophageal conditions have caused granulation tissue at both ends of the stent because of contact between the mucosa and the exposed metal components of the stent, thus hindering stent removal. We examined the tissue response to two new types of SEMS, a flange-type and a straighttype, each coated with a silicone membrane on the outside of the metal mesh. These two SEMS were evaluated individually and compared with a conventional control stent in animal experiments. Although the newly designed stents resulted in reduced tissue hyperplasia, and were thus more easily separated from the esophageal tissue, some degree of tissue hyperplasia did occur. We suggest that newly designed DES (drug-eluting stents) may provide an alternative tool to manage refractory benign esophageal stricture.
Schalij, M J; Udayachalerm, W; Oemrawsingh, P; Jukema, J W; Reiber, J H; Bruschke, A V
1999-09-01
To evaluate the results of long Micro Stent II (MS-XL) implantations, 119 MS-XLs were implanted in 102 patients (age, 62.83 years). Nineteen stents (16%) were implanted in saphenous vein grafts; 100 stents (84%) were implanted in native coronary arteries. Twenty-five patients (25%) were treated because of acute myocardial infarction (AMI); 30 patients (29%) because of unstable angina or angina class IV, and 47 patients (46%) because of stable angina. Eighty-six de novo lesions (84%) and 16 restenotic lesions (16%) were treated. Indications for stent implantation include elective, 61 patients (60%); suboptimal balloon angioplasty result, 22 patients (21%); and bailout after balloon angioplasty, 19 patients (19%). Because of residual thrombus after stenting, 27 patients (26%) received abciximab. All patients received ticlopidin for 28 days and acetylsalicylic acid. One hundred and seventeen MS-XLs (98%) were implanted successfully. Additional (shorter) MS-II were implanted in 40 patients (39%). The stented segment length was 45 +/- 20 mm. The minimum lumen diameter increased from 0.5 +/- 0.5 mm before to 2.7 +/- 0.5 mm after stent implantation. The acute gain was 2.2 +/- 0.4 mm. Early clinical events (<4 weeks) include death, 3 (3%); subacute stent thrombosis, 1 (1%); non-Q-wave infarction, 2 (2%); CABG, 1 (1%); vascular complications, 2 (2%). Late clinical events (<6 months) include acute myocardial infarction, 5 (5%); reintervention, 6 (6%); CABG, 1 (1%). The procedural success rate was 88%, and the event free survival at 6 months was 76%. Stenting of long lesions with the MS-XL was successful and associated with an acceptable complication rate. Cathet. Cardiovasc. Intervent. 48:105-112, 1999. Copyright 1999 Wiley-Liss, Inc.
Savić, Slaviša; Vukotić, Vinka; Lazić, Miodrag; Savić, Nataša
2016-09-01
Currently, ureterorenoscopic (URS) stone fragmentation and removal is the treatment of choice for managing ureteral stones, especially mid and distal ones and is advocated as initial management of ureteric stones. The aim of this work was to evaluate the symptoms, necessity, potential benefits and adverse effects of ureteral stent placement after uncomplicated ureteroscopic lithotripsy. This retrospective-prospective study evaluated a total of 125 patients who had underwent ureteroscopic lithotripsy (URSL). The patients were divided into two groups: stented (59 patients) and unstented (controls, 66 patients). The outcomes measured and compared between the two groups included: stone free rate, postoperative patient pain validated by scale, lower urinary tract symptoms (LUTS), the need for unplanned hospital care, stent related complications, and functional recovery in the form return to normal physical activities. A successful outcome, defined as being stonefree after 12 weeks, was achieved in all 125 (100%) patients. The stone-free rate showed no significant differences between the two groups. LUTS was frequent complaint in the stented group, with statistically significant difference in the domain of frequency/urgency (p = 0.0314). There was a statistically significant difference between the groups in the mean operative time and mean hospitalization time, mean pain visual analog scale (VAS) score and in the use of nonnarcotic analgesic. On the day of the surgery and until postoperative day 3 (POD 3) and postoperative day 5 (POD 5), the pain score was much higher among stented patients than among the controls (p = 0.0001) and non-narcotic analgesic use (p = 0.001) was frequently required in the stented group. Routine placement of ureteral stent after URSL is not mandatory and may be associated with stent side effects. Uncomplicated URSL is safe without stent placement after the treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanciego, Carlos; Miguel, Silvia De; Padilla, Manuel
The purpose of this study was to evaluate, in a prospective, single-center study, the effectiveness of Song's polyurethane stents, modified 'in-house,' in the percutaneous management of epiphora. Patients (n = 170; age range 18-83, mean = 64; 50 male, 120 female) with severe epiphora had the modified stents inserted (183 eyes/195 stents) to treat unilateral/bilateral and complete/partial obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 119 cases (61%) and chronic dacryocystitis in 76 (39%). The set designed by Song was used in all patients but modified by us such that the extreme end is cone-shaped.more » The original technique was slightly modified by us and the procedure was conducted on an outpatient basis. The initial technical success rate of stent placement was 97%. Resolution of epiphora was complete in 180 eyes and partial in 3. On follow-up (mean = 18 months; range: 2 days to 24 months), 165 of 195 stents (85%) remained patent. Primary patency rates at follow-up were 86%, 84%, 84%, and 79% in the first 6 months, second and third 6 months, and the present (24 months), respectively. Stents became obstructed in 30 patients, but all but 2 were easily withdrawn and 20 of these patients remained asymptomatic for a mean of 14 months (secondary patency of 67%). Following stent removal, the withdrawn stent was replaced with a new stent in the same intervention on 14 occasions. In another six cases, patency was re-established without the need of a second stent. The procedure is simple and safe, both in stent insertion as well as in mechanical de-blocking and withdrawal when occluded. Success was >80 % in the short term (1-year follow-up). Stenting failure does not preclude other treatment because with the modification that we had introduced, the extreme end of the stent becomes more accessible to mechanical de-blocking, withdrawal, and relocation. The levels of primary and secondary patencies are promising and warrant more extensive investigation.« less
Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam
2017-09-01
Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P < 0.001). Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.
Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian
2009-04-01
We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.
Ryu, Changwan; Boffa, Daniel; Bramley, Kyle; Pisani, Margaret; Puchalski, Jonathan
2018-02-01
Airway stabilization for severe, symptomatic tracheobronchomalacia (TBM) may be accomplished by silicone Y-stent placement. Common complications of the Y-stent include mucus plugging and granulation tissue formation. We describe a rare case of massive hemoptysis originating from a silicone Y-stent placed for TBM. An emergent bronchoscopy showed an actively bleeding, pulsatile vessel at the distal end of the left bronchial limb of the Y-stent. It was felt that the bleeding was caused by, or at least impacted by, the distal left bronchial limb of the Y-stent eroding into the airway wall. We hypothesized that placement of oxidized regenerated cellulose (ORC) would provide initial hemostasis, and the subsequent placement of a biocompatible surgical sealant would lead to definitive resolution. ORC provided sufficient hemostasis and the subsequent synthetic polymer reinforced the tissue for complete cessation of the bleed. The combined use of ORC and a biocompatible surgical sealant provided long-term management for life-threatening hemoptysis, and potentially morbid procedures such as embolization or surgery were avoided by advanced endobronchial therapy.
Ryu, Changwan; Boffa, Daniel; Bramley, Kyle; Pisani, Margaret; Puchalski, Jonathan
2018-01-01
Abstract Rationale: Airway stabilization for severe, symptomatic tracheobronchomalacia (TBM) may be accomplished by silicone Y-stent placement. Common complications of the Y-stent include mucus plugging and granulation tissue formation. Patient concerns: We describe a rare case of massive hemoptysis originating from a silicone Y-stent placed for TBM. Diagnoses: An emergent bronchoscopy showed an actively bleeding, pulsatile vessel at the distal end of the left bronchial limb of the Y-stent. It was felt that the bleeding was caused by, or at least impacted by, the distal left bronchial limb of the Y-stent eroding into the airway wall. Interventions: We hypothesized that placement of oxidized regenerated cellulose (ORC) would provide initial hemostasis, and the subsequent placement of a biocompatible surgical sealant would lead to definitive resolution. Outcomes: ORC provided sufficient hemostasis and the subsequent synthetic polymer reinforced the tissue for complete cessation of the bleed. Lessons: The combined use of ORC and a biocompatible surgical sealant provided long-term management for life-threatening hemoptysis, and potentially morbid procedures such as embolization or surgery were avoided by advanced endobronchial therapy. PMID:29465600
Kim, Jin Hyoung; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Lee, Sung Koo; Yoon, Hyun-Ki; Shin, Ji Hoon; Song, Ho-Young
2011-06-01
To compare retrospectively percutaneous transhepatic primary placement of a retrievable self-expanding metallic stent with percutaneous balloon dilation for the treatment of benign biliary strictures. From 2005-2009, 66 patients with benign biliary strictures in whom an endoscopic approach failed or in whom such an approach was inaccessible were evaluated. Of 66 patients, 31 underwent balloon dilation, and 35 underwent temporary metallic stent placement. The etiologies of the benign strictures were anastomotic stricture after surgery (n = 54), stricture secondary to intraoperative injury (n = 9), inflammatory stricture (n = 2), and stricture secondary to trauma (n = 1). The primary patency rates were significantly better in the stent group (87% at 3 years) than in the balloon group (44% at 3 years; P = .022). The indwelling period of percutaneous transhepatic biliary drainage (PTBD) catheters after the initial procedure was able to be significantly reduced in the stent group (median 2.5 months) compared with the balloon group (median 4.5 months; P = .001). Significant bleeding (associated with PTBD) occurred in one patient in the balloon group. In the stent group, stent migration occurred in two patients, and one patient underwent surgery for stent removal after failure of removal under fluoroscopic guidance. Percutaneous primary placement of a retrievable self-expanding metallic stent showed superior intermediate-term results compared with percutaneous balloon dilation for the treatment of benign biliary strictures. In addition, the indwelling period of PTBD catheters can be significantly reduced using temporary stent placement. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.
Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui
2016-09-01
Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept "bio-adaption" between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed.
Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review
Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui
2016-01-01
Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept “bio-adaption” between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed. PMID:27698548
Palliation of Malignant Biliary and Duodenal Obstruction with Combined Metallic Stenting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akinci, Devrim, E-mail: akincid@hotmail.com; Akhan, Okan; Ozkan, Fuat
2007-11-15
Purpose. The purpose of this study is to evaluate the efficacy of palliation of malignant biliary and duodenal obstruction with combined metallic stenting under fluoroscopy guidance. Materials and Methods. A retrospective analysis of 9 patients (6 men and 3 women) who underwent biliary and duodenal stenting was performed. The mean age of patients was 61 years (range: 42-80 years). The causes of obstruction were pancreatic carcinoma in 7 patients, cholangiocellular carcinoma in one, and duodenal carcinoma in the other. Biliary and duodenal stents were placed simultaneously in 4 patients. In other 5 patients dudodenal stents were placed after biliary stentingmore » when the duodenal obstruction symptoms have developed. In two patients duodenal stents were advanced via transgastric approach. Results. Technical success rate was 100 %. After percutaneous biliary drainage and stenting bilirubin levels decreased to normal levels in 6 patients and in remaining 3 patients mean reduction of 71% in bilirubin levels was achieved. Tumoral ingrowth occurred in one patient and percutaneous biliary restenting was performed 90 days after the initial procedure. Of the 9 patients, 6 patients were able to tolerate solid diet, whereas 2 patients could tolerate liquid diet and one patient did not show any improvement. Mean survival periods were 111 and 73 days after biliary and duodenal stenting, respectively. Conclusion. Combined biliary and duodenal stent placement which can be performed under fluoroscopic guidance without assistance of endoscopy is feasible and an effective method of palliation of malignant biliary and duodenal obstructions. If transoral and endoscopic approaches fail, percutaneous gastrostomy route allows duodenal stenting.« less
Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A
2017-12-01
To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm 2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.
SX-Ella Danis stent in massive upper gastrointestinal bleeding in cirrhosis - a case series.
Jain, Mayank; Balkrishanan, Mahadevan; Snk, Chenduran; Cgs, Sridhar; Ramakrishnan, Ravi; Venkataraman, Jayanthi
2018-06-01
We report our experience of three cases of decompensated cirrhosis with massive upper gastrointestinal bleeding, which required insertion of an SX-Ella Danis stent for hemostasis. The procedure is safe and effective.
Lausberg, Henning F; Gryszkiewicz, Rafal; Kuetting, Maximilian; Baumgaertner, Moritz; Centola, Marcos; Wendel, Hans-Peter; Nowak-Machen, Martina; Schibilsky, David; Kruger, Tobias; Schlensak, Christian
2017-07-01
Moderate or severe degree tricuspid valve regurgitation (TVR) is associated with high rates of morbidity and mortality. Surgical correction as the only therapeutic option offers unsatisfactory results. Recently, several interventional procedures have been introduced clinically in a limited cohort. We present our initial experiments with an innovative interventional valved stent graft for treatment of TVR. A newly designed porcine pericardium-covered nitinol stent graft with a lateral bicuspid valve was adapted to size in a cadaver study. After haemodynamic testing in an ex vivo perfusion setup, vascular access, valve delivery and function were investigated in an ovine animal model ( n = 7). The device was implanted successfully in all animals. Vascular access was established surgically via the femoral vein without any vascular complications. Angiography demonstrated the correct position of the device with proper sealing of both venae cavae in 6 animals. In 1 extremely large animal, the position of the device was considered too cranial but still acceptable. Correct valve function was verified in all animals by both angiography and echocardiography. There were no persistent arrhythmias other than during valve implant. All animals survived the implant procedure and were sacrificed electively. This study demonstrated that this new valved stent graft could be delivered safely with correct positioning and valve function in this ovine model. Further long-term studies in animals implanted with the device after creation of tricuspid regurgitation are necessary to prove the haemodynamic benefit of this procedure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Garcia-Gutierrez, Juan C; Palacios-Rodríguez, Juan M; Cordova-Correa, Horacio G; Becerra-Laguna, Carlos A; López-López, Hugo A; Salinas Aragón, Miguel A; García-Bonilla, Jorge
2016-01-01
The use of coronary stents in coronary angioplasty has evolved dramatically in its design, type materials, polymers, and a variety of drugs, the use of coronary stents covered nitric oxide have shown satisfactory results in practice, however compared to the results reported drug-eluting stents, there is little information. The aim of this study was to compare clinical outcomes of a stainless steel stent Bioactive nitric oxide coated titanium (BAS) and a drug-eluting stent zotarolimus (DES) in daily clinical practice. A retrospective, analytical, descriptive and comparative study aimed at evaluating the safety and efficacy of two devices with different characteristics in our population. The primary endpoints were: death, acute infarction (AMI), and re intervention injury Treated (RLT). A total of 759 patients were included in the study which was performed angioplasty to a single vessel. Were divided into two arms 382 with DES and 377 patients with BAS, the one year follow up was carried in 95%. After this follow-up period, primary points (cardiovascular death, myocardial infarction, TLR and stent thrombosis) for arm DES vs BAS; 9.5% vs 8.5% P=NS but with shorter periods of dual antiplatelet therapy for arm BAS 6.9±4.1 vs 11.1±2.5 months DES P=.0001. The results were independent of the clinical syndrome of presentation. After one year of follow no statistically significant difference in major clinical events, there was a trend in favour of BAS vs SM with respect to revascularization of the target lesion without reaching statistical significance. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
Ell, C; Hochberger, J; May, A; Fleig, W E; Hahn, E G
1994-09-01
The clinical feasibility of self-expanding metal stents with respect to the technical success, complications, and reintervention rate should be tested. Five coated and 26 uncoated prototype Wallstents, especially designed for stenosis of the upper GI tract, were implanted in 23 patients. All patients with dysphagia suffered from inoperable tumor stenosis of the esophagus or the cardia. Stent implantation was performed under slight i.v. sedoanalgesia. Technical success was achieved in all 31 implanted stents. Forty-eight hr after implantation, dysphagia was improved in 21/23 patients. Acute problems observed within 1 wk were stent migration (1 patient, uncoated stent), oblique position of the stent (3 patients), epigastric or retrosternal pain (9 patients), insufficient stent expansion (4 patients), and pouch formation at the upper rim of the stent (4 patients). An uncomplicated follow-up (median 66 days, range 10-139 days) was seen in 12 patients (52%). Major problems in the follow-up period were stent migration in three patients (three coated stents, two stent migrations in one patient) and stent obstruction by tumor ingrowth/overgrowth and/or food impaction in eight patients (35%). Most of these problems could be successfully resolved by implantation of a second stent or electrocoagulation of overgrowing tumor tissue. By the 1st of March, 1994, three patients were still alive with a follow-up period of 530 days (median range, 336-880 days); 20 patients were decreased with a follow-up period of 70 days (median range, 3-374 days). Implantation of esophageal Wallstents is safe and has a low risk of acute complications and mortality for the patient. Early complications such as perforation and bleeding did not occur. Tumor ingrowth/overgrowth are the major reasons for the high reintervention rate in the follow-up period. Coated stents can resolve this problem, provided that stent migration can be avoided by improvement of the coating technology.
Measurement and Comparison of Mechanical Properties of Nitinol Stents
NASA Astrophysics Data System (ADS)
Hanus, Josef; Zahora, Jiri
2005-01-01
The self expandable Nitinol stents or stentgrafts are typically used for miniinvasive treatment of stenosis and aneurysms in the cardiovascular system. The minimal traumatisation of the patient, shorter time of hospitalization are typical advantages of these methods. More than ten years of experience has yielded also important information about the performance of stents in interaction with biological system and the possible problems related with it. The leakage or the shift of stent are some typical disadvantages, that can be related among other in the construction of the stent. The problem is that the mechanical properties, dimensions and the dynamical properties of the stent do not exactly correspond to the properties of the vessel or generally of tissue where this stent is introduced. The measurement, the description and the comparison of the relations between the mechanical properties of stents and tissues can be one of the possible ways to minimize these disadvantages. The developed original computer controlled measuring system allows the measurement of mechanical properties of stents, the measurement of strain-stress curves or simulation of interaction of the stent and vessel for exactly defined hemodynamic conditions. We measured and compared the mechanical parameters of different selfexpandable Nitinol stents, which differed in geometry (radius and length), in the type of construction (number of branches and rising of winding) and in the diameter of used wire. The results of measurements confirmed the theoretical assumptions that just the diameter of the Nitinol wire significantly influences the rigidity and the level of compressibility of the stent as well. A compromise must be found between the required rigidity of the stent and the minimal size of the delivery system. The exact description of the relation between the mechanical properties and geometry and construction of the stents enables to design the stent to fit the patient and it is expected that this access improves the efficiency of treatment. The results of measurement are also necessary for the design and identification of the parameters of the models of the stents.
Williams, D M; Andrews, J C; Chee, S S; Marx, M V; Abrams, G D
1994-01-01
To develop a percutaneous treatment for aortic rupture with use of a covered intraluminal stent. A transmural tear was created percutaneously in the thoracic aorta in six dogs with use of a 4-mm angioplasty balloon. Gianturco Z stents were covered with polytetrafluoroethylene, loaded into a 14-F sheath, and advanced through the femoral artery to the site of injury. Within 2 minutes after initiation of the injury, the stent was deployed. Homologous canine blood was given during the procedure. Dogs that survived 24 hours were then killed. The first stent did not expand completely, and the dog died in 1 hour. At necropsy, the first two dogs (1-hour and 8-hour survival) had a large left hemothorax and extensive periaortic hematoma, indicating intrathoracic exsanguination. The next four dogs were treated with a modified stent and survived 2 hours (n = 1), 8 hours (n = 1), and 24 hours (n = 2). At necropsy hemothorax did not exceed 15 mL, and periaortic hematomas were small. The cause of death in the two early casualties with the modified stent is uncertain. There were no signs of spinal cord injury despite occlusion of three pairs of intercostal arteries. The covered Z stent (in its modified form) tamponaded the aortic tear, preventing exsanguination. Long-term studies of biocompatibility of this device appear justified.
Eisenberg, Michael L; Elliott, Sean P; McAninch, Jack W
2007-12-01
We describe our experience with urethral stents to manage iatrogenic posterior urethral stenosis. We surveyed our retrospective database for patients in whom we placed a urethral stent for posterior urethral stricture disease. We reviewed patient age, comorbidities, indications for stent placement, stricture length, postoperative complications and the repeat stenosis rate. Overall we placed urethral stents in 13 patients, of whom 12 presented with posterior urethral stenosis and 1 presented with anterior and posterior stricture. The etiology of urethral stricture was prostate cancer therapy in 11 of 13 cases and simple prostatectomy in 2. Urethral stenting was chosen instead of urethral reconstruction largely due to prior radiation for prostate cancer and avoidance of the morbidity of surgery. Overall 6 of 13 patients required additional procedures for stricture recurrence, including 5 in previously irradiated patients. Two patients had stents removed due to migration or pain. Genitourinary infections developed in 5 of 13 patients. Eight of 13 patients with a posterior urethral stricture were incontinent, as expected after stent placement. Incontinence was managed by an artificial urinary sphincter in willing patients with 9 of 13 continent. Urethral stents provide reasonable treatment for patients with posterior urethral stenosis when attempting to preserve lower urinary tract function caused by stricture disease after prostate cancer therapy. Prior radiation seems to increase the failure rate. Continence can be maintained after posterior urethral stenting in select patients.
Sedat, Jacques; Chau, Yves; Gaudart, Jean; Sachet, Marina; Beuil, Stephanie; Lonjon, Michel
2018-02-01
Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.
Performance of a self-expanding silicone stent in palliation of benign airway conditions.
Gildea, Thomas R; Murthy, Sudish C; Sahoo, Debashish; Mason, David P; Mehta, Atul C
2006-11-01
The Polyflex stent (Boston Scientific; Boston, MA) is a self-expanding, thin-walled, silicone stent. Its use has been described in the management of patients with malignant airway obstruction, yet reports of its use for treatment of benign airway conditions are rare. We report a retrospective review of our experience with the Polyflex stent in the management of benign airway conditions. A total of 16 stents were deployed in 12 patients. The indications for the stent placement included the following: anastomotic stenosis following lung transplantation (LTR) [four patients]; tracheal stenosis (three patients); tracheobronchomalacia (two patients); tracheobronchopathiaosteochondroplastica (one patient); relapsing polychondritis (one patient); and bronchopleural fistula (one patient). Even though immediate palliation was established in most cases (90%), the incidence of complications was 75%. Stent migration was the most common consequence, with time to the event ranging from < 24 h to 7 months. One stent was expectorated within < 24 h. One patient coughed up a portion of the inner lining of the stent 7 months after its placement. Emergent bronchoscopy was required in four patients for mucous impaction. The complication rate was 100% in patients with LTR-related anastomotic stenosis. The use of the Polyflex stent for the treatment of benign airway conditions is associated with a high complication rate. We have abandoned its use under such conditions in our practice.
Vellody, Ranjith; Willatt, Jonathon M; Arabi, Mohammad; Cwikiel, Wojciech B
2011-01-01
To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.
Gerbay, Antoine; Terreaux, Jeremy; Cerisier, Alexis; Vola, Marco; Isaaz, Karl
Percutaneous coronary intervention (PCI) for bifurcation lesions (BL) using 2 stents technique is known to be associated with high rates of procedural failure especially on the side branch (SB) mainly due to stent incomplete apposition. Stent deployment at very high pressure (SDHP) may lead to better stent expansion and apposition. However, SDHP may also be at the origin of deeper wall injury resulting into major cardiac adverse events. No data are available on evaluation of SDHP in BL treated by a mini-crush stent technique. One hundred and thirteen consecutive patients underwent PCI for BL (Medina 1, 1, 1) using a mini-crush stent technique with SDHP defined as ≥20atm. An angiographic follow-up was performed at 6 month and clinical follow-up was obtained at a median of 3 years. Stent deployment mean pressures were 20±1.4atm (range 20-25) in the main vessel (MV) and 20±1.5atm (range 20-25) in SB. Simultaneous final kissing balloon was used in 92% of cases. PCI was successful in 100%. Angiographic follow-up was obtained in 83% of patients. Restenosis rate was 13% (12% restenosis in the SB) with only one case (0.8%) of SB probable thrombosis. Another case of late stent thrombosis occurred at a 3 years clinical follow-up. Compared with previously published studies in which stents were deployed at lower pressure, SDHP does not increase the restenosis rate in BL using mini-crush stent technique but seems to reduce the rate of stent thrombosis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Computational fluid dynamics evaluation of incomplete stent apposition in a tapered artery
NASA Astrophysics Data System (ADS)
Poon, Eric; Thondapu, Vikas; Ooi, Andrew; Hayat, Umair; Barlis, Peter; Moore, Stephen
2015-11-01
Coronary stents are deployed to prop open blocked arteries and restore normal blood flow, however in-stent restenosis (ISR) and stent thrombosis (ST) remain possibly catastrophic complications. Computational fluid dynamics (CFD) analyses can elucidate the pathological impact of alterations in coronary hemodynamics and correlate wall shear stress (WSS) with atherosclerotic processes. The natural tapering of a coronary artery often leads to proximal incomplete stent apposition (ISA) where stent struts are not in contact with the vessel wall. By employing state-of-the-art computer-aided design (CAD) software, generic open-cell and closed-cell coronary stent designs were virtually deployed in an idealised tapered coronary artery. Pulsatile blood flow (80 mL/min at 75 beats/min) was carried out numerically on these CAD models using a finite volume solver. CFD results reveal significant fluctuations in proximal WSS and large recirculation regions in the setting of proximal ISA, resulting in regions of high wall shear stress gradient (WSSG) that have been previously linked to poor endothelial cell coverage and vascular injury. The clinical significance of these proximal high WSSG regions will be correlated with findings from high-resolution in-vivo imaging. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).
Canena, Jorge; Coimbra, João; Carvalho, Diana; Rodrigues, Catarina; Silva, Mário; Costa, Mariana; Horta, David; Mateus Dias, António; Seves, Isabel; Ramos, Gonçalo; Ricardo, Leonel; Coutinho, António Pereira; Romão, Carlos; Veiga, Pedro Mota
2014-11-01
Self-expandable metal stents (SEMSs) can be used for palliation of combined malignant biliary and duodenal obstructions. However, the results of the concomitant stent placement for the duration of the patients' lives, as well as the need for and efficacy of endoscopic revision, are unclear. This study evaluated the clinical effectiveness of SEMS placement for combined biliary and duodenal obstructions throughout the patients' lives and the need for endoscopic revision. This study is a retrospective multicenter study of 50 consecutive patients who underwent simultaneous or sequential SEMS placement for malignant biliary and duodenal obstructions. The data were collected to analyze the sustained relief of obstructive symptoms until the patients' death and the efficacy of endoscopic revision, as well as stent patency, adverse events, survival and prognostic factors for stent patency. Technical and immediate clinical success was achieved in all of the patients. Duodenal stricture occurred before the papilla in 35 patients (70 %), involved the papilla in 11 patients (22 %) and was observed distal to the papilla in four patients (8 %). Initial biliary stenting was performed endoscopically in 42 patients (84 %) and percutaneously in eight patients. After combined stenting, 30 patients (60 %) required no additional intervention until the time of their death. The remaining 20 patients were successfully treated using endoscopic stent reinsertion: nine patients needed biliary revision, three patients needed duodenal restenting and eight patients needed both biliary and duodenal reinsertion. The median duodenal stent patency and median biliary stent patency were 34 and 27 weeks, respectively. The median survival after combined stent placement was 18 weeks. A Cox multivariate analysis showed that duodenal stent obstruction after combined stenting was a risk factor for biliary stent obstruction (hazard ratio 6.85; 95 % confidence interval 1.43-198.98; P = 0.025). Endoscopic bilio-duodenal bypass is clinically effective, and the majority of the patients need no additional intervention until their death. Endoscopic revision is feasible and has a high success rate.
Gardner, Timothy B; Spangler, Chad C; Byanova, Katerina L; Ripple, Gregory H; Rockacy, Matthew J; Levenick, John M; Smith, Kerrington D; Colacchio, Thomas A; Barth, Richard J; Zaki, Bassem I; Tsapakos, Michael J; Gordon, Stuart R
2016-09-01
The optimal type of stent for the palliation of malignant biliary obstruction in patients with pancreatic adenocarcinoma undergoing neoadjuvant chemoradiotherapy with curative intent is unknown. We performed a prospective trial comparing 3 types of biliary stents-fully covered self-expandable metal (fcSEMS), uncovered self-expandable metal (uSEMS), and plastic-to determine which best optimized cost-effectiveness and important clinical outcomes. In this prospective randomized trial, consecutive patients with malignant biliary obstruction from newly diagnosed pancreatic adenocarcinoma who were to start neoadjuvant chemoradiotherapy were randomized to receive fcSEMSs, uSEMSs, or plastic stents during the index ERCP. The primary outcomes were time to stent occlusion, attempted surgical resection, or death after the initiation of neoadjuvant therapy, and the secondary outcomes were total patient costs associated with the stent, including the index ERCP cost, downstream hospitalization cost due to stent occlusion, and the cost associated with procedural adverse event. Fifty-four patients were randomized and reached the primary end point: 16 in the fcSEMS group, 17 in the uSEMS group, and 21 in the plastic stent group. No baseline demographic or tumor characteristic differences were noted among the groups. The fcSEMSs had a longer time to stent occlusion compared with uSEMSs and plastic stents (220 vs 74 and 76 days, P < .01), although the groups had equivalent rates of stent occlusion, attempted surgical resection, and death. Although SEMS placement cost more during the index ERCP (uSEMS = $24,874 and fcSEMS = $22,729 vs plastic = $18,701; P < .01), they resulted in higher procedural AE costs per patient (uSEMS = $5522 and fcSEMS = $12,701 vs plastic = $0; P < .01). Conversely, plastic stents resulted in an $11,458 hospitalization cost per patient due to stent occlusion compared with $2301 for uSEMSs and $0 for fcSEMSs (P < .01). In a prospective trial comparing fcSEMSs, uSEMSs, and plastic stents for malignant biliary obstruction in patients undergoing neoadjuvant therapy with curative intent for pancreatic adenocarcinoma, no stent type was superior in optimizing cost-effectiveness, although fcSEMSs resulted in fewer days of neoadjuvant treatment delay and a longer time to stent occlusion. (Clincial trial registration number: NCT01038713.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Avitabile, Catherine M; Harris, Matthew A; Doddasomayajula, Ravi S; Chopski, Steven G; Gillespie, Matthew J; Dori, Yoav; Glatz, Andrew C; Fogel, Mark A; Whitehead, Kevin K
2018-06-15
Little data are available on the accuracy of phase-contrast magnetic resonance imaging (PC-MRI) velocity mapping in the vicinity of intravascular metal stents other than nitinol stents. Therefore, we sought to determine this accuracy using in vitro experiments. An in vitro flow phantom was used with 3 stent types: (1) 316L stainless steel, (2) nitinol self-expanding, and (3) platinum-iridium. Steady and pulsatile flow was delivered with a magnetic resonance imaging-compatible pump (CardioFlow 5000, Shelley Medical, London, Ontario, Canada). Flows were measured using a transit time flow meter (ME13PXN, Transonic, Inc, Ithaca, New York). Mean flows ranged from 0.5 to 7 L/min. For each condition, 5 PC-MRI acquisitions were made: within the stent, immediately adjacent to both edges of the stent artifact, and 1 cm upstream and downstream of the artifact. Mean PC-MRI flows were calculated by segmenting the tube lumen using clinical software (ARGUS, Siemens, Inc, Erlangen, Germany). PC-MRI and flow meter flows were compared by location and stent type using linear regression, Bland-Altman, and intraclass correlation (ICC). PC-MRI flows within the stent artifact were inaccurate for all stents studied, generally underestimating flow meter-measured flow. Agreement between PC-MRI and flow meter-measured flows was excellent for all stent types, both immediately adjacent to and 1 cm away from the edge of the stent artifact. Agreement was highest for the platinum-iridium stent (R = 0.999, ICC = 0.999) and lowest for the nitinol stent (R = 0.993, ICC = 0.987). In conclusion, PC-MRI flows are highly accurate just upstream and downstream of a variety of clinically used stents, supporting its use to directly measure flows in stented vessels. Copyright © 2018 Elsevier Inc. All rights reserved.
Yang, Wen Jie; Zhang, Huan; Xiao, Hua; Li, Jian Ying; Liu, Yan; Pan, Zi Lai; Chen, Ke Min
2012-01-01
The evaluation of coronary stents by computed tomography (CT) remains difficult. We assessed the imaging performance of a high-definition CT scanner (HDCT) by comparing with a conventional 64-row standard-definition CT (SDCT). One hundred thirty-eight consecutive stented patients underwent coronary CT angiography, among whom 66 patients were examined by HDCT, and 72 patients by SDCT (LightSpeed VCT XT; GE Healthcare, Waukesha, Wis). The image quality score, the inner stent diameter (ISD), and the radiation dose were analyzed. All data were statistically tested by SPSS 13.0 software (SPSS Inc, Chicago, Ill). In 72 patients examined using SDCT, 135 stents were detected; in 66 patients examined using HDCT, 119 stents were detected. The image quality score on HDCT was significantly better than that on SDCT (1.4 [SD, 0.7] vs 1.9 [SD, 0.8]). The ISD on HDCT was significantly higher than that on SDCT (1.8 [SD, 0.5] vs 1.6 [SD, 0.4]). There was no significant difference of either image quality score or ISD between the HDCT and SDCT groups in stents with 2.5-mm diameter. Images on HDCT showed significantly better image quality score and larger ISD than images on SDCT in 2.75-, 3-, and 3.5-mm stents. For patients examined by retrospective electrocardiogram-gated technique, the radiation dose on HDCT was significantly lower than that on SDCT (11.3 [SD, 2.9] vs 15.1 [SD, 3.8] mSv). High-definition CT scanner offered improved image quality and measurement accuracy for imaging coronary stents compared with conventional SDCT, providing higher spatial resolution and lower dose for evaluating coronary stents with 2.75- to 3.5-mm diameter.
Persson, Saga; Rouvelas, Ioannis; Kumagai, Koshi; Song, Huan; Lindblad, Mats; Lundell, Lars; Nilsson, Magnus; Tsai, Jon A.
2016-01-01
Background and study aim: The endoscopic placement of self-expandable metallic esophageal stents (SEMS) has become the preferred primary treatment for esophageal anastomotic leakage in many institutions. The aim of this study was to investigate possible risk factors for failure of SEMS-based therapy in patients with esophageal anastomotic leakage. Patients and methods: Beginning in 2003, all patients with an esophageal leak were initially approached and assessed for temporary closure with a SEMS. Until 2014, all patients at the Karolinska University Hospital with a leak from an esophagogastric or esophagojejunal anastomosis were identified. Data regarding the characteristics of the patients and leaks and the treatment outcomes were compiled. Failure of the SEMS treatment strategy was defined as death due to the leak or a major change in management strategy. The risk factors for treatment failure were analyzed with simple and multivariable logistic regression statistics. Results: A total of 447 patients with an esophagogastric or esophagojejunal anastomosis were identified. Of these patients, 80 (18 %) had an anastomotic leak, of whom 46 (58 %) received a stent as first-line treatment. In 29 of these 46 patients, the leak healed without any major change in treatment strategy. Continuous leakage after the application of a stent, decreased physical performance preoperatively, and concomitant esophagotracheal fistula were identified as independent risk factors for failure with multivariable logistic regression analysis. Conclusion: Stent treatment for esophageal anastomotic leakage is successful in the majority of cases. Continuous leakage after initial stent insertion, decreased physical performance preoperatively, and the development of an esophagotracheal fistula decrease the probability of successful treatment. PMID:27092321
Kocur, Damian; Zbroszczyk, Miłosz; Przybyłko, Nikodem; Hofman, Mariusz; Jamróz, Tomasz; Baron, Jan; Bażowski, Piotr; Kwiek, Stanisław
We report our experience with stent-assisted coiling of anterior communicating artery aneurysms with special consideration of angiographic and clinical outcomes, retreatment rate and periprocedural complications. The analysis included 34 consecutive ruptured and unruptured wide-neck aneurysms. The aneurysm size ranged from 2 to 18mm (mean 5.47). Clinical examinations with the use of modified Rankin Score and angiographic outcomes were evaluated initially post-embolization and at a minimum follow-up of 6 months. Initial post-treatment complete and near-complete aneurysm occlusion was achieved in 32 (94%) and 2 (6%) cases, respectively. Imaging follow-up, performed in 28 (82%) patients, showed no change in the degree of occlusion in 25 (89%) cases and coil compaction in 3 (11%) patients. Of these, one (3.6%) patient underwent a second coil embolization. The periprocedural severe complication rate was 2.9% (1/35) and was associated with prolonged attempt of retrieval of migrated coil resulting in anterior cerebral artery infarct with serious clinical consequences. In another 3 patients periprocedural adverse events without delayed clinical consequences were noticed. The clinical follow-up evaluation achieved in 33 (97%) patients showed no change in 30 (91%) cases, one patient (3%) with clinical improvement and two (6%) cases of neurological deterioration. The use of stent is feasible and effective for coil embolization of wide-necked anterior communicating artery aneurysms. Although periprocedural complications resulting in severe morbidity are rare, they should be noted, since in terms of thromboembolic events some of them presumably have a potential to be avoidable. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Mpotsaris, Anastasios; Kabbasch, Christoph; Borggrefe, Jan; Gontu, Vamsi; Soderman, Michael
2017-04-01
Background Emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy is a routine procedure. Yet, precise indications and clinical safety in this setting remains controversial. Present data for mechanical thrombectomy include few studies with acute stenting of tandem occlusions. We evaluated the feasibility, safety and clinical outcome of this endovascular treatment in a retrospective analysis of all consecutive cases at a comprehensive stroke centre. Methods This was a retrospective analysis of all consecutive patients with acute extracranial carotid artery occlusion including acute dissection or high-grade stenosis and concomitant intracranial large-vessel occlusion treated with emergency carotid stenting and intracranial mechanical thrombectomy between November 2007 and May 2015. Results A total of 63 patients with a median age of 67 years (range 33-84 years) were treated. Of these, 33 (52%) patients had concomitant intravenous thrombolysis with recombinant tissue-type plasminogen activator initially. Median admission National Institutes of Health Stroke Scale was 14 (range 1-29). Median time from stroke onset to recanalization was 408 minutes (range 165-1846 minutes). Procedure time was significantly shorter after intravenous thrombolysis (110 minutes [range 15-202 minutes] vs. 130 minutes [range 60-280 minutes]; p = 0.02). Three (5%) patients experienced post-procedural symptomatic intracerebral haemorrhage. In 55/63 (87%) patients, a score of ≥2b on the Thrombolysis in Cerebral Infarction scale could be achieved. Eight (13%) patients died, five (8%) during the acute phase. A total of 29/63 (46%) patients showed a favourable outcome (modified Rankin Scale score of 0-2) after three months. Conclusions Our single-centre retrospective analysis of emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy demonstrated high technical success, reasonable clinical outcomes and acceptable rates of symptomatic intracranial haemorrhage in carefully chosen patients which are triaged interdisciplinary based on clinical and computed tomography imaging criteria. This warrants further study in a randomised prospective trial.
Treatment of gastric leaks with coated self-expanding stents after sleeve gastrectomy.
Serra, Carlos; Baltasar, Aniceto; Andreo, Luis; Pérez, Nieves; Bou, Rafael; Bengochea, Marcelo; Chisbert, Juan José
2007-07-01
Duodenal switch (DS) is one of the most effective techniques for the treatment of morbid obesity and its co-morbidities, with mortality rate <1%, but with 9.4% morbidity rates (6.5% due to leaks). In our experience, leaks of the staple-line after sleeve gastrectomy (SG) are the most frequent sites of fistula formation and conservative treatment usually takes a long time. We present our experience in the treatment of gastric leaks with coated self-expandable stents (CSES). 6 patients had gastric leaks at the gastroesophageal (GE) junction after SG or DS. One patient had a symptomatic gastro-bronchial fistula. Stents were placed by the interventional radiologist under fluoroscopic control and removed endoscopically. In one case, we used an uncoated Wallstent. In two patients, percutaneous microcoil embolization of the fistula was added. The patient treated with the Wallstent required a total gastrectomy 6 months after placement of the uncovered stent. In the other 5 patients, coated stents were successfully removed and the gastric leaks completely sealed. CSES are proposed as an alternative therapeutic option for the management of GE junction leaks in bariatric surgery with good results in terms of morbidity and survival.
Fully covered self-expandable metal stent in tracheobronchial disorders: clinical experience.
Marchese, Roberto; Poidomani, Grazia; Paglino, Giuseppe; Crimi, Claudia; Lo Nigro, Chiara; Argano, Vincenzo
2015-01-01
The third-generation fully covered self-expandable metallic stent (SEMS) has been developed to solve the problems of difficult removal and in-stent granuloma formation related to the uncovered or partially covered type. There are few written reports about the performance of this type of stents with early encouraging results. To report and analyse our experience with the Silmet® stent in the management of malignant and benign tracheobronchial disorders. We retrospectively reviewed medical records of patients who underwent fully covered SEMS Silmet placement at the Interventional Pulmonology Unit, La Maddalena Cancer Center, Palermo, Italy, between May 2010 and August 2013. Stents were placed in 52 patients with malignant (n = 49) and benign airway obstruction (n = 2) and broncho-oesophageal fistula (n = 1). SEMSs were inserted into the trachea (n = 19), the main bronchi (n = 21) and the peripheral bronchi (n = 31). Besides 1 procedural dislocation, the deployment was successful in all patients with an immediate significant improvement of symptoms (Barthel Index p < 0.001; Medical Research Council score p < 0.001). A radiographic improvement was detected in 48% of patients. The mean follow-up duration was 119 ± 120 days (range 22-549 days). Complications observed were: migration (7.6%), tumour overgrowth (15%), infections (5.7%), granulation tissue formation (3.8%) and mucus plug (3.8%). The Silmet stent is effective, safe and simple to implant and remove. We suggest its use in cases of tight stenoses, in the treatment of small- to medium-caliber airways or in cases of tortuous airways. © 2015 S. Karger AG, Basel.
Gwon, Dong Il; Ko, Gi-Young; Yoon, Hyun-Ki; Kim, Jin Hyoung; Lee, Jae Myeong; Ohm, Joon-Young; Sung, Kyu-Bo
2010-09-01
To investigate the technical and clinical safety and efficacy of using a newly designed T-configured stent graft for palliative treatment of advanced hilar malignant biliary obstructions. This is a prospective study that enrolled 30 patients who had malignant hilar obstructions from May 2007 to November 2008. All patients were treated with percutaneous transhepatic placement of two specially designed stent grafts in a T configuration. Technical success, evaluation of blocked branching ducts, complications, clinical success, stent patency time, and patient survival rates were analyzed. Stent graft deployment was technically successful in all patients. The bilirubin level and the bile duct diameter decreases were statistically significant after stent placement (P < .001), and all patients showed clinical improvement. Minor complications, including procedure-related complications (self-limiting hemobilia [n = 3], perihepatic biloma [n = 1], and acute pancreatitis [n = 1]) and rapidly resolving cholangitis (n = 5), occurred in ten patients (33.3%). Major complications, including acute cholecystitis, occurred in three patients (10%). Stent occlusion occurred in 12 patients (40%) after a mean period of 160 days (range, 82-307 days). The median survival and stent patency times were 334 days (range, 195.6-472.4 days) and 279 days (range, 194.7-363.3 days), respectively. There were no statistical differences in age, sex, Bismuth type, or number of blocked branching ducts. The initial results of percutaneous palliative treatment of advanced hilar malignancies with T-configured stent grafts suggest that they are safe and potentially clinically effective. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.
Use of a nitinol stent to palliate a colorectal neoplastic obstruction in a dog
Culp, William T. N.; MacPhail, Catriona M.; Perry, James A.; Jensen, Tracey D.
2015-01-01
Case Description A 12-year-old castrated male Labrador Retriever was evaluated for clinical signs associated with colorectal obstruction. Clinical Findings The dog had a 2-week history of tenesmus and hematochezia. On rectal examination, an annular colorectal mass was palpable extending orad into the pelvic canal. The original diagnosis of the colorectal mass was a mucosal adenoma. The dog was maintained on a low-residue diet and fecal softeners for a period of 13 months after initial diagnosis. At that time, medical management was no longer effective. Treatment and Outcome Placement of a colonic stent was chosen to palliate the clinical signs associated with colorectal obstruction. By use of fluoroscopic and colonoscopic guidance, a nitinol stent was placed intraluminally to open the obstructed region. Placement of the stent resulted in improvement of clinical signs, although tenesmus and obstipation occurred periodically after stent placement. At 212 days after stent placement, the patient had extensive improvement in clinical signs with minimal complications; however, clinical signs became severe at 238 days after stent placement, and the dog was euthanized. Histologic evaluation of the rectal tumor from samples obtained during necropsy revealed that the tumor had undergone malignant transformation to a carcinoma in situ. Clinical Relevance A stent was successfully placed in the colon and rectum to relieve obstruction associated with a tumor originally diagnosed as a benign neoplasm. Placement of colorectal stents may be an option for the palliation of colorectal obstruction secondary to neoplastic disease; however, clinical signs may persist, and continuation of medical management may be necessary. PMID:21756178
Sousa, Paula; Castanheira, António; Martins, Diana; Pinho, Juliana; Araújo, Ricardo; Cancela, Eugénia; Ministro, Paula; Silva, Américo
2017-07-01
The use of self-expandable metal stents (SEMS) for the treatment of postoperative leaks of the upper gastrointestinal tract is already established. However, there are discrepancies between the relatively small caliber of the esophageal stents available and the postsurgical luminal size, which may determine an inadequate juxtaposition. As colonic stents have a bigger diameter, they might be more adequate. Additionally, stents with a larger diameter might have a lower risk of migration. The aim of this study was to evaluate the efficacy and complications associated with the use of colonic fully covered SEMS (FSEMS) in the treatment of postoperative leaks in critical patients. All patients with postoperative leaks of the upper gastrointestinal tract treated with colonic stents (Hanarostent® CCI) between 2010 and 2013 were retrospectively included. Four patients with postoperative leaks were treated with colonic SEMS. The underlying surgeries were a gastric bypass, an esophagogastrectomy for Boerhaave syndrome, a primary repair of esophagopleural fistula due to Boerhaave syndrome, and an esophagectomy due to esophageal cancer. The leaks were detected on average 17 days after the initial surgery. All patients needed admission to a critical care unit after index surgery. Stent placement was technically feasible in all patients. The median residence time of the stents was 7 weeks, and no complications were verified when they were removed. There were no cases of stent migration. The treatment was successful in all patients, with complete healing of the leaks. The placement of colonic FSEMS seems to be successful and safe in the treatment of postoperative leaks of the upper gastrointestinal tract.
Corcoran, Anthony T; Smaldone, Marc C; Mally, Dev; Ost, Michael C; Bellinger, Mark F; Schneck, Francis X; Docimo, Steven G; Wu, Hsi-Yang
2008-10-01
We studied the possibility that age, height, weight and body mass index could be used to predict the likelihood of successful ureteroscopic access to the upper urinary tract without previous stent placement in prepubertal children. We retrospectively reviewed all ureteroscopic procedures for upper tract calculi in prepubertal children from 2003 to 2007. We compared age, height, weight and body mass index in patients who underwent successful primary flexible ureteroscopic access and in those who required initial stent placement to perform ureteroscopy. Successful primary ureteroscopic access to the upper tract was achieved in 18 of 30 patients (60%). There was no difference in mean age (9.9 vs 9.5 years, p = 0.8), height (132 vs 128 cm, p = 0.6), weight (37 vs 36 kg, p = 0.86) or body mass index (19.3 vs 20.5 kg/m(2), p = 0.55) between patients with successful vs unsuccessful upper tract access. Locations that prevented access to the upper urinary tract were evenly distributed among the ureteral orifice, iliac vessels and ureteropelvic junction. Age, height, weight and body mass index could not predict the likelihood of successful ureteroscopic access to the upper tract. Placement of a ureteral stent for passive ureteral dilation is not necessary for successful ureteroscopic access to the renal pelvis in prepubertal children. An initial attempt at ureteroscopy, with placement of a ureteral stent if upper tract access is unsuccessful, decreases the number of procedures while maintaining a low complication rate.
An uncommon case of antegrade stent causing serious persistent haematuria
Ejikeme, Chidozie M.
2015-01-01
Introduction Transient minor bleeding after nephrostomy tube placement is very common, occurring in up to 95% of cases. Often this is due to small vessel or venous bleeding. Severe post procedure bleeding requiring transfusion or other intervention is RARE. Presentation of case A case of a 79 year old man, who had antegrade stent insertion for 10 mm left upper ureteric stone. He was alright for up to one week but developed severe haemturia requiring three way catheter. Catheter was blocking regularly and needed to go to theatre for bladder washout. No source of bleeding was found in bladder. CT renal angiogram revealed his stent has migrated into the nephrostomy tract. He was taken to theatre and had his stent changed. His haematuria settled. Discussion The severe bleeding recorded in this case could not have been attributed to the stent, though the initial bleeding following the procedure has settled it seemed likely to blame vascular injury following PCN as the cause of bleeding. Subsequent CT scan was able to point at the right source of bleeding. Conclusion All possibilities should be considered when presented with a case severe bleeding following antegrade stent insertion. PMID:25797353
An uncommon case of antegrade stent causing serious persistent haematuria.
Ejikeme, Chidozie M
2015-01-01
Transient minor bleeding after nephrostomy tube placement is very common, occurring in up to 95% of cases. Often this is due to small vessel or venous bleeding. Severe post procedure bleeding requiring transfusion or other intervention is RARE. A case of a 79 year old man, who had antegrade stent insertion for 10mm left upper ureteric stone. He was alright for up to one week but developed severe haemturia requiring three way catheter. Catheter was blocking regularly and needed to go to theatre for bladder washout. No source of bleeding was found in bladder. CT renal angiogram revealed his stent has migrated into the nephrostomy tract. He was taken to theatre and had his stent changed. His haematuria settled. The severe bleeding recorded in this case could not have been attributed to the stent, though the initial bleeding following the procedure has settled it seemed likely to blame vascular injury following PCN as the cause of bleeding. Subsequent CT scan was able to point at the right source of bleeding. All possibilities should be considered when presented with a case severe bleeding following antegrade stent insertion. Copyright © 2015 The Author. Published by Elsevier Ltd.. All rights reserved.
Open-cell vs. Closed-cell Stent Design Differences in Blood Flow Velocities after Carotid Stenting
Pierce, Damon S.; Rosero, Eric B; Modrall, J Gregory; Adams-Huet, Beverley; Valentine, R James; Clagett, G Patrick; Timaran, Carlos H
2009-01-01
Objective The differential effect of stent design, i.e. open-cell vs. closed-cell configuration, on carotid velocities detected by duplex ultrasonography (DUS) has not been established. To identify possible stent design differences in carotid velocities, we analyzed our experience with DUS obtained before and immediately after CAS. Methods In a series of 141 CAS procedures performed over a 3 year period, data from the first postinterventional DUS and carotid angiograms were evaluated for each patient. Peak systolic velocities (PSV), end-diastolic velocities (EDV), and internal carotid artery-to-common carotid artery (ICA-CCA) PSV ratios were compared according to stent design. Differences in carotid velocities were analyzed using nonparametric statistical tests. Results Completion angiogram revealed successful revascularization and less that 30% residual stenosis in each case. The 30-day stroke-death rate in this series was 1.6% and was unrelated to stent type. Postintervention DUS was obtained a median of 5 days after CAS (interquartile range [IQR], 1–25 days). Closed-cell stents were used in 41 cases (29%) and open-cell stents in 100 cases (71%). The median PSV was significantly higher for closed-cell stents (122cm/s; IQR, 89–143cm/s) than for open-cell stents (95.9cm/s; IQR, 77.–123) (P=.007). Median EDV (36 vs. 29 cm/s; P=.006) and median ICA-CCA PSV ratio (1.6 vs. 1.1; P=.017) were also significantly higher for closed-cell stents. 45% of closed-cell stents had carotid velocities that exceeded the threshold of 50% stenosis by DUS criteria for a nonstented artery compared to 26% of open-cell stents (P=.04). In fact, closed cell-stents had a 2.2-fold increased risk of yielding abnormally elevated carotid velocities after CAS compared with open-cell stents (odds ratio, 2.2; 95% confidence interval, 1.02–4.9). Conclusions Carotid velocities are disproportionately elevated after CAS with closed-cell stents compared with open-cell stents, which suggests that velocity criteria for quantifying stenosis may require modification according to stent design. The importance of these differences in carotid velocities related to stent design and the potential relationship with recurrent stenosis remains to be established. PMID:19268763
Song, Min; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Jung, Hwoon-Yong; Kim, Jong-Hoon; Kim, Sung-Bae
2011-09-01
To retrospectively evaluate the incidence, predictive factors, and interventional management of food impaction after expandable metallic stent placement in patients with obstruction of the esophagus or upper gastrointestinal tract caused by benign or malignant disease. Between March 1993 and March 2010, 1,360 patients (1,029 men, 331 women; age range, 21-89 y; mean age, 61 y) underwent fluoroscopically guided stent placement for dysphagia caused by esophageal or gastrointestinal tract strictures. Five types of covered expandable metal stents were used, including four types of esophageal stents (types A-D) and one type of gastroduodenal stent (type E), with types A, B, C, D, and E stents used in 180, 60, 90, 432, and 598 patients, respectively. Multivariate analysis was performed to evaluate factors predictive of food impaction. Food impaction occurred in 41 of 1,360 patients (3.0%). The food impaction rates for types A, B, C, D, and E stents were 0.6%, 1.7%, 1.1%, 3.2%, and 4.0%, respectively. Multivariate analysis showed that stent length was an independent predictor of food impaction (odds ratio, 0.839; P = .012). Of the 41 patients with food impaction, 23 underwent endoscopic management, 12 underwent fluoroscopically guided management, and six did not require management because impacted food spontaneously passed through the stent. The overall food impaction rate was 3.0%, with multiple logistic regression analysis showing that shorter stent length was the only significant predictor of food impaction. Food impaction can be managed by endoscopic or fluoroscopically guided removal or placement of a second stent. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Iliocaval Confluence Stenting for Chronic Venous Obstructions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graaf, Rick de, E-mail: r.de.graaf@mumc.nl; Wolf, Mark de, E-mail: markthewolf@gmail.com; Sailer, Anna M., E-mail: anni.sailer@mumc.nl
PurposeDifferent techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions.Materials and MethodsBetween 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) ormore » high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents.ResultsRecanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days.ConclusionStenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.« less
Use of covered self-expandable stents for benign colorectal disorders in children.
Lange, Bettina; Sold, Moritz; Kähler, Georg; Wessel, Lucas M; Kubiak, Rainer
2017-01-01
There is a lack of experience with covered self-expandable stents for benign colorectal disorders in children. Five children (4M, 1F) with a median age of 5years (range, 6months-9years) who underwent treatment with covered self-expandable plastic (SEPSs) or self-expandable metal stents (SEMSs) for a benign colorectal condition between April 2005 and November 2013 were recruited to this retrospective study. Etiologies included: anastomotic stricture with (n=1) or without (n=3) simultaneous enterocutaneous fistula, as well as an anastomotic leak associated with enterocutaneous fistula (n=1). All children suffered from either Hirschsprung's disease (n=3) or total colonic aganglionosis (Zuelzer-Wilson syndrome) (n=2). Median duration of individual stent placement was 23days (range, 1-87days). In all cases up to five different stents were placed over time. At follow-up two patients were successfully treated without further intervention. In another patient the anastomotic stricture resolved fully, but a coexisting enterocutaneous fistula persisted. Overall, three patients did not improve completely following stenting and required definite surgery. Stent-related problems were noted in all cases. There was one perforation of the colon at stent insertion. Further complications consisted of stent dislocation (n=4), obstruction (n=1), formation of granulation tissue (n=1), ulceration (n=1) and discomfort (n=3). Covered self-expandable stents enrich the armamentarium of interventions for benign colorectal disorders in children including anastomotic strictures and intestinal leaks. A stent can be applied either as an emergency procedure (bridge to surgery) or as an adjuvant treatment further to endoscopy and dilatation. Postinterventional problems are frequent but there is a potential for temporary or definite improvement following stent insertion. Copyright © 2017. Published by Elsevier Inc.
Evolution of the Ureteral Stent: The Pivotal Role of the Gibbons Ureteral Catheter.
Donahue, Ryan P; Stamm, Andrew W; Gibbons, Robert P; Porter, Christopher R; Kobashi, Kathleen C; Corman, John M; Lee, Una J
2018-05-01
To review the pioneering contributions of Dr. Robert Gibbons of Virginia Mason Medical Center to the evolution and development of the modern ureteral stent. We reviewed Dr. Gibbons' extensive work through primary sources, including interviews, projector slides, radiology images, stent prototypes, his personal writings, and archived documents. In addition, we performed a review of historical texts and manuscripts describing important innovations in the development of the ureteral stent. In 1972, motivated by a desire to provide his patients with a long-term alternative to open nephrostomy and inspired by Drs. David Davis and Paul Zimskind, who in 1967 had described the use of indwelling ureteral silicone tubing, Dr. Gibbons began to experiment with modifications to improve upon existing stents. To address distal migration, Dr. Gibbons added "wings" that collapsed as the stent was advanced and expanded once in proper position to secure the stent in place. Barium was embedded into the proximal tip to facilitate radiographic visualization. A flange was added to the distal end, preventing proximal migration and minimizing trigonal irritation, and a tail was attached to aid in stent removal. The result was the original Gibbons stent, the first commercially available ureteral stent, and the establishment of Current Procedural Terminology code 52332, still used today. The ureteral stent is a fundamental component of urologic practice. In developing the Gibbons stent, Dr. Gibbons played a pivotal role in addressing the challenge of internal urinary diversion particularly for those who needed long-term management. Urologists and the patients they serve owe Dr. Gibbons and other surgeon-inventors a debt of gratitude for their innovative work. Copyright © 2018 Elsevier Inc. All rights reserved.
Ferreira, Marcelo; Ferreira, Diego; Cunha, Rodrigo; Bicalho, Guilherme; Rodrigues, Eduardo
2018-06-01
To demonstrate different techniques and device modifications that can expand the anatomic suitability of the off-the-shelf multibranched t-Branch for treatment of thoracoabdominal aortic aneurysm. The t-Branch device is not customized for specific patient anatomy, and the most frequent limitations to its use are an inadequate sealing zone and renal artery anatomy. Experience with this device has prompted the development of several techniques that can be employed to maximize the suitability of this stent-graft. Advice is offered on modification of the device to minimize the risk of paraplegia or better match patient anatomy. Maneuvers are explained to ease delivery through tortuous anatomy or existing stent-grafts, catheterize visceral target vessels, select a bridging stent, reduce ischemia time in the limbs, and alter the configuration of the branches. Employing adjunctive maneuvers can increase the anatomic suitability of the t-Branch; in our experience, these techniques have increased the applicability to more than 80% of all elective and urgent thoracoabdominal aortic aneurysm cases.
Mufarrij, Patrick W; Rajamahanty, Srinivas; Krane, L Spencer; Hemal, Ashok K
2012-09-01
An integral component of many urologic reconstructive surgical procedures is the positioning of a Double-J stent to span the anastomosis. Some surgeons prefer to place a retrograde stent during cystoscopy, either during or after the reconstruction. In this communication, we describe our straightforward and effective approach of performing this critical step intracorporeally using robotic assistance in a variety of upper tract urologic reconstructive procedures. We examined our Institutional Review Board-approved database of robotic surgeries to identify reconstructive operations that included the intracorporeal placement of a Double-J stent since 2008. Our step-by-step method for stent placement during various robotic urologic reconstructions is detailed, including procedures involving the proximal, mid, and distal ureter. With the aid of a bedside assistant-surgeon, we delineate how the console surgeon is able to perform this step of the procedure completely intracorporeally, without the need for repositioning or cystoscopy. Since the inception of our robotic surgical program in 2008, we have used these robotic stent placement techniques in 150 patients. The average time of robotic intracorporeal stent placement across the anastomosis was 3.5 minutes. Three patients did experience proximal stent migration, as documented on postoperative radiographs, but all were treated with conservative measures, because their anastomosis was not affected and severe symptoms did not develop. No patient needed stent replacement, and each stent was subsequently removed ureteroscopically without sequelae. Our robotic intracorporeal Double-J stent placement approach is simple and effective, avoids the need for cystoscopy and fluoroscopy, and can be used in any type of upper urinary tract urologic reconstruction.
Management of postoperative esophageal leaks with the Polyflex self-expanding covered plastic stent.
Langer, Felix B; Wenzl, Etienne; Prager, Gerhard; Salat, Andreas; Miholic, Johannes; Mang, Thomas; Zacherl, Johannes
2005-02-01
Esophageal anastomotic leaks can lead to prolonged hospitalization. In this article we present our experience with the placement of the Polyflex self-expanding plastic stent (Willy Ruesch GMBH, Kernen, Germany) for leak occlusion. Between April 2000 and November 2003, 24 patients were included into this prospective study and underwent Polyflex stent placement for postoperative esophageal anastomotic leaks. The primary operation was esophagectomy in 13 patients, gastrectomy in 7, cardia resection in 2, and other procedures in 2 patients. The median interval between operation and stent placement was 19 days (range, 4 to 65). The effectiveness of leak occlusion was evaluated by water-soluble contrast swallow and the clinical course. In 2 patients stent misplacement produced an enlarged anastomotic dehiscence that necessitated reoperation. Radiologic evaluation was impossible in 4 patients because of their generally restricted condition. Among 18 evaluable patients, leak occlusion was successful with a single stent in 16 patients (89%) based on radiologic evaluation. Immediate oral feeding was well tolerated by these patients. After a median follow-up of 220 days (range, 7 to 1221), 9 cases of late stent dislocation were observed. Stent removal in patients after esophagectomy with gastric pull-up led to dysphagia from anastomotic strictures in 2 patients. Symptomatic strictures did not develop in the 5 evaluable postgastrectomy patients after stent removal. The placement of self-expanding plastic stents is a highly effective treatment for esophageal anastomotic leaks. Because clinically-relevant anastomotic strictures can be expected, we do not recommend stent removal after esophagectomy with gastric pull-up reconstruction.
Postoperative esophageal leak management with the Polyflex esophageal stent.
Freeman, Richard K; Ascioti, Anthony J; Wozniak, Thomas C
2007-02-01
Leak after esophageal anastomosis or perforation repair prolongs hospitalization, prevents oral hydration and nutrition, and can produce localized infection or sepsis. This investigation reviews our experience treating postoperative esophageal leaks with the Polyflex esophageal stent (Boston Scientific, Natick, Mass). Over a 30-month period, patients with a postoperative esophageal leak were treated with the Polyflex stent for leak occlusion. Leak occlusion was confirmed by means of esophagraphy. Patients were followed until their stent was removed and their esophageal leak had resolved. Twenty-one patients had 27 stents placed for leak occlusion after esophagectomy (n = 5), esophageal perforation (n = 5), surgical (n = 4) or endoscopic (n = 2) antireflux procedure, and esophageal diverticulectomy (n = 3) or myotomy (n = 2). The mean interval between surgical intervention and stent placement was 12 +/- 8 days (range, 3-31 days). Occlusion of the leak occurred in 20 patients. One patient experienced a dehiscence of the surgical esophageal perforation repair requiring esophageal diversion. Stent migration requiring repositioning (n = 3) or replacement (n = 4) occurred in 5 (24%) patients. Twenty (95%) stents were removed without residual leak (mean, 51 +/- 43 days; range, 15-175 days). One patient had a stricture after stent removal that required endoscopic dilatation. One patient in this series died. The Polyflex esophageal stent is an effective method for occluding a postoperative esophageal leak. It rapidly eliminates contamination of the mediastinum, pleura, and peritoneum; allows oral hydration and nutrition; and is easily removable. These stents also offer an appealing alternative to traditional esophageal diversion and subsequent reconstruction in patients with a persistent esophageal leak.
Coskun, Ayhan; Coban, Yusuf Kenan; Vardar, Mehmet Ali; Dalay, Ahmet Cemil
2007-07-10
Mc Indoe vaginoplasty is one of the mostly performed surgical interventions in Mullerian agenesis. We present our experience on the use of a new designed vaginal stent that was coated with silicone in two mullerian agenesis cases who had Mc Indoe vaginoplasty. Both full thickness and splitt thickness skin graft were used with the stent. No graft loss or hyperthrophic scarring which may be seen at the apex of neovagina after Mc Indoe vaginoplasty was observed during the follow-up period and adequate neovaginal depth were obtained in both of the patients. We think that the incorporation of silicone to a vaginal stent for postoperative wound care improves skin graft take and decreases a possible constriction band formation in neovagina.
Kumagai, Hozumi; Nio, Kenta; Shirakawa, Tsuyoshi; Uchino, Keita; Kusaba, Hitoshi; Isobe, Taichi; Komoda, Masato; Tamura, Shingo; Maeyama, Ryo; Nagai, Eishi; Akashi, Koichi; Baba, Eishi
2012-09-19
Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient's general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.
Wang, Xiaoqing; Zhang, Long; Chen, Qihui; Hou, Yuchuan; Hao, Yuanyuan; Wang, Chunxi; Shan, Hongli
2015-12-01
A degradable polycaprolactone(PCL)/poly(lactic-co-glycolic acid, LA:GA = 80:20) (PLGA) ureter tubular stent was fabricated by electrospinning. The structure and properties of the stents were investigated by the mechanical property testing, scanning electron microscopy (SEM), degradability test in vitro and MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay. The stent was transplanted to the dorsal muscle of rabbit to evaluate its tissue compatibility. It was shown that the stent has the nano-structure. The mechanical test showed that with the increase in PCL concentration, the mechanical properties of the stent gradually increased, and it could meet the demands of a urethral stent. The collapse time of different concentration of PCL/PLGA (5%, 15%, and 25%) was 28, 42, and 56 days, respectively. These results provide strong evidence that the degradation time can be increased with the increase in PCL concentration. The results of the MTT assay show that the PCL/PLGA stent had no cytotoxicity. In muscle implantation tests, acute tissue reactions due to operation trauma were seen in all specimens at 1 week. After four weeks, the number of inflammatory cells had decreased significantly. Only a few inflammatory cells were seen in the PCL/PLGA stent group after 12 weeks, and the foreign body reaction was more severe in the control group. Animal orthotopic transplantation experiments of these ureteral stents will be done to evaluate its degradable model and tissue compatibility.
Biodegradable airway stents in infants - Potential life-threatening pitfalls.
Sztanó, B; Kiss, G; Márai, K; Rácz, G; Szegesdi, I; Rácz, K; Katona, G; Rovó, L
2016-12-01
The solution of severe tracheobronchial obstructions in early childhood means a great challenge. Biodegradable stents were intended to be a minimally invasive temporary solution which may decrease the number of interventions and limit the possible complications of stenting procedures. However, our first experiences have brought out a new, - especially in childhood - potentially life-threatening complication of this concept. Five SX-ELLA biodegradable polydioxanone stents was applied in three patients because of severe tracheobronchial obstruction: congenital tracheomalacia (7 day-old), acquired tracheomalacia (10 month-old), and congenital trachea-bronchomalacia (10 month-old). The breathing of all children improved right after the procedure. We observed degradation of the stent from the 5th postoperative week which resulted in large intraluminar fragments causing significant airway obstruction: one patient died of severe pneumonia, the other baby required urgent bronchoscopy to remove the obstructing 'foreign body' from the trachea. In the third case repeated stent placements successfully maintained the tracheal lumen. Polydioxanone stents may offer an alternative to metallic or silastic stents for collapse or external compression of the trachea in children; however, large decaying fragments mean a potential risk especially in the small size pediatric airway. The fragmentation of the stent, which generally starts in the 4-6 postoperative weeks, may create large sharp pieces. These may be anchored to the mucosa and covered by crust leading to obstruction. As repeated interventions are required, we do not consider the application of biodegradable stents unambiguously advantageous. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Radiotherapy Dose Perturbation of Esophageal Stents Examined in an Experimental Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atwood, Todd F.; Hsu, Annie; Ogara, Maydeen M.
2012-04-01
Purpose: To investigate the radiotherapy dose perturbations caused by esophageal stents in patients undergoing external beam treatments for esophageal cancer. Methods and Materials: Four esophageal stents were examined (three metallic stents: WallFlex, Ultraflex, and Alveolus; one nonmetallic stent with limited radiopaque markers for visualization: Polyflex). All experiments were performed in a liquid water phantom with a custom acrylic stent holder. Radiochromic film was used to measure the dose distributions adjacent to the stents at locations proximal and distal to the radiation source. The stents were placed in an air-filled cavity to simulate the esophagus. Treatment plans were created and deliveredmore » for photon energies of 6 and 15 MV, and data analysis was performed on uniform regions of interest, according to the size and geometric placement of the films, to quantify the dose perturbations. Results: The three metallic stents produced the largest dose perturbations with distinct patterns of 'hot' spots (increased dose) measured proximal to the radiation source (up to 15.4%) and both 'cold' (decreased dose) and hot spots measured distal to the radiation source (range, -6.1%-5.8%). The polymeric Polyflex stent produced similar dose perturbations when the radiopaque markers were examined (range, -7.6%-15.4%). However, when the radiopaque markers were excluded from the analysis, the Polyflex stent produced significantly smaller dose perturbations, with maximum hot spots of 7.3% and cold spots of -3.2%. Conclusions: The dose perturbations caused by esophageal stents during the treatment of esophageal cancer using external beam radiotherapy should be understood. These perturbations will result in hot and cold spots in the esophageal mucosa, with varying magnitudes depending on the stent. The nonmetallic Polyflex stent appears to be the most suitable for patients undergoing radiotherapy, but further studies are necessary to determine the clinical significance of the dose perturbations.« less
Radiotherapy dose perturbation of esophageal stents examined in an experimental model.
Atwood, Todd F; Hsu, Annie; Ogara, Maydeen M; Luba, Daniel G; Tamler, Bradley J; Disario, James A; Maxim, Peter G
2012-04-01
To investigate the radiotherapy dose perturbations caused by esophageal stents in patients undergoing external beam treatments for esophageal cancer. Four esophageal stents were examined (three metallic stents: WallFlex, Ultraflex, and Alveolus; one nonmetallic stent with limited radiopaque markers for visualization: Polyflex). All experiments were performed in a liquid water phantom with a custom acrylic stent holder. Radiochromic film was used to measure the dose distributions adjacent to the stents at locations proximal and distal to the radiation source. The stents were placed in an air-filled cavity to simulate the esophagus. Treatment plans were created and delivered for photon energies of 6 and 15 MV, and data analysis was performed on uniform regions of interest, according to the size and geometric placement of the films, to quantify the dose perturbations. The three metallic stents produced the largest dose perturbations with distinct patterns of "hot" spots (increased dose) measured proximal to the radiation source (up to 15.4%) and both "cold" (decreased dose) and hot spots measured distal to the radiation source (range, -6.1%-5.8%). The polymeric Polyflex stent produced similar dose perturbations when the radiopaque markers were examined (range, -7.6%-15.4%). However, when the radiopaque markers were excluded from the analysis, the Polyflex stent produced significantly smaller dose perturbations, with maximum hot spots of 7.3% and cold spots of -3.2%. The dose perturbations caused by esophageal stents during the treatment of esophageal cancer using external beam radiotherapy should be understood. These perturbations will result in hot and cold spots in the esophageal mucosa, with varying magnitudes depending on the stent. The nonmetallic Polyflex stent appears to be the most suitable for patients undergoing radiotherapy, but further studies are necessary to determine the clinical significance of the dose perturbations. Copyright © 2012 Elsevier Inc. All rights reserved.
Automatic segmentation of the wire frame of stent grafts from CT data.
Klein, Almar; van der Vliet, J Adam; Oostveen, Luuk J; Hoogeveen, Yvonne; Kool, Leo J Schultze; Renema, W Klaas Jan; Slump, Cornelis H
2012-01-01
Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion characteristics of stent grafts will be beneficial for designing future devices. In addition, analysis of stent graft movement in individual patients in vivo can be valuable for predicting stent graft failure in these patients. To be able to gather information on stent graft motion in a quick and robust fashion, we propose an automatic method to segment stent grafts from CT data, consisting of three steps: the detection of seed points, finding the connections between these points to produce a graph, and graph processing to obtain the final geometric model in the form of an undirected graph. Using annotated reference data, the method was optimized and its accuracy was evaluated. The experiments were performed using data containing the AneuRx and Zenith stent grafts. The algorithm is robust for noise and small variations in the used parameter values, does not require much memory according to modern standards, and is fast enough to be used in a clinical setting (65 and 30s for the two stent types, respectively). Further, it is shown that the resulting graphs have a 95% (AneuRx) and 92% (Zenith) correspondence with the annotated data. The geometric model produced by the algorithm allows incorporation of high level information and material properties. This enables us to study the in vivo motions and forces that act on the frame of the stent. We believe that such studies will provide new insights into the behavior of the stent graft in vivo, enables the detection and prediction of stent failure in individual patients, and can help in designing better stent grafts in the future. Copyright © 2011 Elsevier B.V. All rights reserved.
Holmes, D R; Lansky, A; Kuntz, R; Bell, M R; Buchbinder, M; Fortuna, R; O'Shaughnessy, C D; Popma, J
2000-11-15
A new martensitic nitinol stent with improved flexibility and radiopacity was tested to evaluate whether these differences improve initial or long-term outcome. Patients who underwent percutaneous revascularization of a discrete native coronary lesion were randomly assigned to the new stent (PARAGON, n = 349) or to the first-generation Palmaz-Schatz (PS) stent (n = 339). The primary end point was target vessel failure at 6 months (a composite of cardiac or noncardiac death, any infarction in the distribution of the treated vessel, or clinically indicated target vessel revascularization). Secondary end points were, among others, device and procedural success and angiographic restenosis. Mean age was 62 years; diabetes was present in 21% of patients, prior bypass surgery in 6%, and recent infarction in 22% (p = NS for comparison between the 2 randomized arms). The PARAGON stent group had smaller reference vessels (2.97 vs 3.05 mm, p = 0.05), more prior restenosis (8.0% vs 4.5%, p = 0.07), and a longer average stent length (21.3 vs 19.4 mm, p < 0.05). Device success was significantly higher in the PARAGON arm (99.1% vs 94.3%, p < 0.05). Death and infarction at 6-month follow-up were infrequent in both groups. There was no significant difference in death (2.0% vs 1.2%, p = 0.546), but a higher rate of infarction for the PARAGON cohort (9.2% vs 4.7%, p = 0.025). Although target vessel failure (20.3% vs 12.4%, p = 0.005) and target lesion revascularization (12.0% vs 5.9%, p = 0.005) were higher in the PARAGON group, there was no significant difference in 6-month follow-up in in-stent minimal lumen diameter or in the rate of binary angiographic restenosis. Both PARAGON and PS stents are safe and associated with infrequent adverse events. The PARAGON stent can be delivered more frequently than the first-generation PS stent. Although there was no significant difference in in-stent minimal lumen diameter or the frequency of angiographic restenosis, clinical restenosis was more frequent in the PARAGON group.
Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J
2006-08-15
Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.
Martin, Robert; Duvall, Ryan; Ellis, Susan; Scoggins, Charles R
2009-03-01
Preoperative nutritional supplementation, management of esophageal leaks, and postoperative anastomotic strictures still remain common problems in the management of esophageal cancer. Jejunal feeding tubes, total parenteral nutrition (TPN) with nasogastric suction, and repeated esophageal dilations remain the most common treatments, respectively. The aim of this study was to evaluate the use of removable silicone stents in (1) the preoperative nutritional optimization during neoadjuvant therapy, (2) the management of perioperative anastomotic leak, and (3) the management of postoperative anastomotic strictures. Review of our prospectively maintained esophageal database identified 15 patients who had removable self-expanding silicone stents placed in the management of one of these three management problems from July 2004 to August 2006. Preoperative therapy: Five patients underwent initial stent placement in preparation for neoadjuvant therapy. Dysphagia relief was seen in 100% of patients, with optimal caloric needs taken within 24 h of placement. All patients tolerated neoadjuvant therapy without delay from dehydration or malnutrition. One stent migration was found at the time of operation, which was removed without sequelae. Perioperative therapy: Five patients developed delayed (>10 days) esophageal leaks that were managed with removable esophageal stent and percutaneous drainage (in three patients). All patients had successful exclusion of the leak on the day of the procedure with resumption of oral intake on the evening of procedure. All five healed leaks without sequelae. Postoperative therapy: Five patients developed postoperative anastomotic strictures that required dilation and placement of removable esophageal stent. The median number of dilations was 1 (range 1-2), with all stents placed for approximate 3 months duration. All patients had immediate dysphagia relief after stent placement. Removable esophageal stents are novel treatment option to optimize relief of symptoms and return the patients back to a more normal oral intake. Continued evaluation is needed to consider stent use as first-line therapy.
Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Profili, Stefano; Manca, Antonio; Feo, Claudio F.
2007-02-15
Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technicalmore » success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated.« less
Lai, Andrew; Lipka, Seth; Kumar, Ambuj; Sethi, Sajiv; Bromberg, David; Li, Nanxing; Shen, Huafeng; Stefaniwsky, Lilia; Brady, Patrick
2018-04-01
More than 50% of patients with esophageal cancer already have inoperable disease at the time of diagnosis. Controversy surrounds the outcomes of patients with advanced esophageal cancer who receive palliative care by either stent alone or stent plus an additional modality. We set out to perform a systematic review and meta-analysis of studies assessing the use of metal stents as treatment options for symptomatic improvement, survival, and adverse events. We searched Embase, MEDLINE, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception until January 14, 2016, as well as other databases for randomized controlled trials (RCTs) comparing esophageal stent versus either esophageal stent plus brachytherapy, radiotherapy, or chemotherapy. For quality assurance purposes throughout the systematic review, multiple independent extractions were performed, and the process was executed as per the standards of the Cochrane collaboration. Primary outcomes were mean change in dysphagia score, overall survival, and quality of life. Secondary outcomes were adverse events including fever, severe pain, aspiration, fistula, stent migration, perforation, and restenosis. Eight RCTs enrolling 732 patients were included with three distinct comparisons: stents combination therapy vs stents alone (5 studies, n = 417), stents alone versus brachytherapy alone (2 studies, n = 274), and stents + brachytherapy vs brachytherapy alone (1 study, n = 41). Stents combination therapy was defined as stents plus radiotherapy, chemotherapy, or both. Mean change in dysphagia scores favored stents combination therapy versus stents alone, and the effect was seen in patients surviving longer than 3 months. Stents combination therapy was also associated with a more favorable overall survival. The risks of stent migration, aspiration pneumonia, and restenosis were lower in the stents combination group compared to stents alone, while the risks of severe pain, hemorrhage, and fistula formation were higher. Changes in dysphagia scores and overall survival did not differ significantly in the brachytherapy-alone vs stents-alone comparison. The risk of fistula formation and hemorrhage were higher in the stents-alone group, while the risk of perforation was lower, compared to brachytherapy alone. Quality of life improvements were seen in all treatment groups, but were not pooled in analysis due to differing methods of measurement. While there appears to be no immediate short-term differences, those who live longer than 3 months experience a significant improvement in dysphagia score using a stents combination therapy approach vs stents alone. The combination therapy significantly improves the overall survival as well as showed improvements in quality of life scores. Larger randomized controlled trials are needed to assess improvements in dysphagia score, overall survival, quality of life, and adverse events.
Stent Repair for Complex Coarctation of Aorta.
Suárez de Lezo, José; Romero, Miguel; Pan, Manuel; Suárez de Lezo, Javier; Segura, José; Ojeda, Soledad; Pavlovic, Djordje; Mazuelos, Francisco; López Aguilera, José; Espejo Perez, Simona
2015-08-24
This study sought to determine whether several anatomic or evolving characteristics of the coarctation may create challenging conditions for treatment. Stent repair of coarctation of aorta is an alternative to surgical correction. We analyzed our 21-year experience in the percutaneous treatment of complex coarctation of aorta. Adverse conditions for treatment were as follow: 1) complete interruption of the aortic arch (n = 11); 2) associated aneurysm (n = 18); 3) complex stenosis (n = 30); and 4) the need for re-expansion and/or restenting (n = 21). Twenty patients (33%) belonged to more than 1 group. Ten interruptions were type A and 1 was type B. The mean length of the interrupted aorta was 9 ± 11 mm. The associated aneurysms were native in 8 patients and after previous intervention in 10 patients. Aneurysm shapes were fusiform in 8 patients and saccular in 10. The following characteristics defined complex stenosis as long diffuse stenosis, very tortuous coarctation, or stenosis involving a main branch or an unusual location. Patients previously stented at an early age, required re-expansion and/or restenting after reaching 16 ± 5 years of age. Two patients had died by 1-month follow-up. The remaining 58 patients did well and were followed-up for a mean period of 10 ± 6 years. Late adverse events occurred in 3 patients (5%). All remaining patients are symptom-free, with normal baseline blood pressure. Imaging techniques revealed good patency at follow-up without associated aneurysm or restenosis. The actuarial survival free probability of all complex patients at 15 years was 92%. Stent repair of complex coarctation of aorta is feasible and safe. Initial results are maintained at later follow-up. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopera, Jorge E., E-mail: jloper@lsuhsc.edu; Kirsch, David; Qian Zhong
2005-05-15
The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiogramsmore » were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.« less
Lopera, Jorge E; Kirsch, David; Qian, Zhong; Ruiz, Bernardo; Brazzini, Augusto; Gonzales, Arturo; Castaneda-Zuniga, Wilfrido
2005-01-01
The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiograms were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.
Laparoscopic trans-mesocolic pyeloplasty in children: initial experience from a center in India.
Khan, Muneer; Ahangar, Shahnawaz; Nazir, Syed Sajjad; Qadri, Syed Javid Farooq; Salroo, Nazir Ahmad
2011-07-01
The aim of the present study is to report our experience with laparoscopic pyeloplasty via trans-mesocolic approach in children with left pelvi-ureteric junction (PUJ) obstruction. Between May 2007 and May 2008, 12 children aged between five and 16 years, with documented PUJ obstruction on the left side, underwent laparoscopic pyeloplasty via trans-mesocolic approach. The outcome was assessed by post-operative isotope renal scan. The mean age of the study patients was eight years, ranging between five and 16 years. There were five males and seven females in the study. All children underwent Anderson Hynes Pyeloplasty by a single surgeon. All cases were stented with a JJ stent for a period of six weeks post-operatively. The procedures were completed successfully in all patients without need for conversion to open pyeloplasty in any patient. The mean operative time was 95 min, with a range of 80-140 min. The average blood loss was 57 mL. The mean hospital stay was 3.5 days with a range of 2.5 to six days. All children returned back to school within nine days following surgery. The mean follow-up period was 12 months (range, nine to 14 months). Eleven of the patients were completely asymptomatic, while one reported mild flank pain. All children underwent renal scans and renal ultrasound three months after stent removal. Ten had improved function on the scan while in one patient, the function remained the same and, in another, it showed obstructed response to diuretic, although the symptoms had improved. In all the cases, renal ultrasound showed a decrease in the severity of hydronephrosis by at least one degree. These results confirm that laparoscopic pyeloplasty by trans-mesocolic approach in children for left-sided PUJ obstruction is safe and feasible.
King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J
2015-12-01
The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (p<0.001), ICH (p=0.001), mortality among all patients (p=0.03), and recanalization (p=0.02) were more commonly reported in NEU treated aneurysms. The ENT system was also associated with higher reported complete occlusion at follow-up (p<0.001). This literature review represents the largest and most robust comparison of stent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com; Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr; Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr
2013-04-15
The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payermore » perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.« less
Jiménez, Juan M.; Prasad, Varesh; Yu, Michael D.; Kampmeyer, Christopher P.; Kaakour, Abdul-Hadi; Wang, Pei-Jiang; Maloney, Sean F.; Wright, Nathan; Johnston, Ian; Jiang, Yi-Zhou; Davies, Peter F.
2014-01-01
Drug eluting stents are associated with late stent thrombosis (LST), delayed healing and prolonged exposure of stent struts to blood flow. Using macroscale disturbed and undisturbed fluid flow waveforms, we numerically and experimentally determined the effects of microscale model strut geometries upon the generation of prothrombotic conditions that are mediated by flow perturbations. Rectangular cross-sectional stent strut geometries of varying heights and corresponding streamlined versions were studied in the presence of disturbed and undisturbed bulk fluid flow. Numerical simulations and particle flow visualization experiments demonstrated that the interaction of bulk fluid flow and stent struts regulated the generation, size and dynamics of the peristrut flow recirculation zones. In the absence of endothelial cells, deposition of thrombin-generated fibrin occurred primarily in the recirculation zones. When endothelium was present, peristrut expression of anticoagulant thrombomodulin (TM) was dependent on strut height and geometry. Thinner and streamlined strut geometries reduced peristrut flow recirculation zones decreasing prothrombotic fibrin deposition and increasing endothelial anticoagulant TM expression. The studies define physical and functional consequences of macro- and microscale variables that relate to thrombogenicity associated with the most current stent designs, and particularly to LST. PMID:24554575
Tracheal T-Tube Stent for Laryngotracheal Stenosis: Ten Year Experience
Dass, Arjun; M Nagarkar, Nitin; K Singhal, Surinder; Verma, Hitesh
2014-01-01
Introduction: The purpose of this retrospective study was to evaluate the outcome following stenting over a period of 10 years in patients with chronic laryngotracheal stenosis. Materials and Methods: Between 2000–2010, out of 111 patients with laryngotracheal trauma, 71 underwent tracheal T-stenting for laryngotracheal stenosis in the Department of Otorhinolaryngology at the Government Medical College and Hospital, Chandigarh, India. All 71 patients underwent stenting by tracheal T-stent through an external approach. The follow-up period ranged from 3–10 years (mean, 3.2 years). The tracheal T-stent was removed after a minimum period of 6–12 months. Results: The majority of patients in this study were aged less than 10 years or between the ages of 20–30 years. A pre-operative tracheostomy (emergency or elective) was performed in all patients. of 71 patients, decannulation was not possible in six (8%). Conclusion: Management of laryngotracheal stenosis is a challenging problem that demands a multidisciplinary approach from surgical teams well trained in this field. The ideal treatment option should be individualized according to patient characteristics. The use of silastic stents has both advantages and disadvantages. PMID:24505573
Coskun, Ayhan; Coban, Yusuf Kenan; Vardar, Mehmet Ali; Dalay, Ahmet Cemil
2007-01-01
Background Mc Indoe vaginoplasty is one of the mostly performed surgical interventions in Mullerian agenesis. Case presentations We present our experience on the use of a new designed vaginal stent that was coated with silicone in two mullerian agenesis cases who had Mc Indoe vaginoplasty. Both full thickness and splitt thickness skin graft were used with the stent. No graft loss or hyperthrophic scarring which may be seen at the apex of neovagina after Mc Indoe vaginoplasty was observed during the follow-up period and adequate neovaginal depth were obtained in both of the patients. Conclusion We think that the incorporation of silicone to a vaginal stent for postoperative wound care improves skin graft take and decreases a possible constriction band formation in neovagina. PMID:17623058
Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging
Haworth, Kevin J.; Raymond, Jason L.; Radhakrishnan, Kirthi; Moody, Melanie R.; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E.; Kim, Hyunggun; Mcpherson, David D.; Holland, Christy K.
2015-01-01
Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. PMID:26547633
[A Case of Peritoneal Metastasis in Which Colostomy Was Useful for Restenosis after Stenting].
Tagawa, Hiroko; Yoshimatsu, Kazuhiko; Yokomizo, Hajime; Yano, Yuki; Nakayama, Mao; Okayama, Sachiyo; Satake, Masaya; Sakuma, Akiko; Matsumoto, Atsuo; Fujimoto, Takashi; Shiozawa, Shunichi; Shimakawa, Takeshi; Katsube, Takao; Kato, Hiroyuki; Naritaka, Yoshihiko
2015-11-01
We report a case of restenosis after performing stenting twice for ileus caused by peritoneal dissemination that occurred after surgery for sigmoid colon cancer, in which colostomy was performed to improve the patient's QOL. The patient was a 58-year-old woman who underwent sigmoidectomy for sigmoid colon cancer. She presented with a peritoneal recurrence 3 times, and the third surgery was a non-curative resection. Chemotherapy was administered but was discontinued because of severe adverse events, and the patient was followed up with the best supportive care. An anastomotic stricture occurred 4 years after the initial surgery, and despite performing stenting twice, stenosis occurred 3 times within a few months. The third stenosis occurred shortly after the second episode, and colostomy was therefore performed. The patient died from cancer 4 months after colostomy without having another episode of stenosis. Although stenting is effective for patients with malignant colon stenosis, colostomy appears to be more effective for repeated post-stenting stenosis, when the patient is in an eligible general condition.
Barncord, Kristin; Stauthammer, Christopher; Moen, Sean L; Hanson, Melissa; Gruenstein, Daniel H
2016-03-01
An 11 month old spayed, female dog presented with exercise intolerance and cyanosis upon exertion. Echocardiography revealed an imperforate cor triatriatum dexter with mild tricuspid valve dysplasia, an underfilled right ventricle and significant right to left shunting across a presumptive patent foramen ovale. Balloon dilation of the abnormal atrial membrane was initially successful in creating a communication between the right atrial chambers, but stenosis of the original perforation and persistent clinical signs prompted a second intervention. A balloon expandable biliary stent was placed across the abnormal partition, improving caudal venous return to the right ventricle and reducing the right to left shunt. Three months after stent placement, resting oxygen saturation had normalized. Six months after stent placement, exercise tolerance had improved and exertional cyanosis had resolved. Long term follow up will be necessary to assess for remodeling of the right ventricle with improved venous return. Stent placement can be considered as a palliative treatment option for cor triatriatum dexter, especially for stenosis post-balloon dilation. Copyright © 2015 Elsevier B.V. All rights reserved.
Analysis of trends and prospects regarding stents for human blood vessels.
Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo
2018-01-01
The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used to supplement and complement the primary research. Interviews were conducted with physicians and surgeons from the key hospitals and senior sale/marketing managers from stent product suppliers in South Korea. The global stent market is estimated at US $ 7.98 billion in 2016 and is expected to grow at a Compound Annual Growth Rate (CAGR) of 3.8% over the next 5 years. As of 2016, the global market for vascular stents is estimated at $ 7.22 billion, with coronary artery stents accounting for 67.3% of the vascular stent market. Among the coronary artery stents, BRS is notably expected to grow at an annual average rate of 8.8% by 2020, but the global adoption rate of BRS remains low at present. In the Korean market, stents for blood vessels account for most of the market, and the market size of stents for blood vessels in Korea was estimated to be 145 billion won as of 2016. In comparison to the sales growth rate of other medical devices, the future stent technology market is judged to be higher in growth potential.
Ozgul, Mehmet A; Cetinkaya, Erdogan; Cortuk, Mustafa; Iliaz, Sinem; Tanriverdi, Elif; Gul, Sule; Ozgul, Guler; Onaran, Hilal; Abbasli, Kenan; Dincer, Huseyin E
2017-04-01
Expiratory central airway collapse (ECAC) is abnormal central airway narrowing during expiration. ECAC involves 2 different pathophysiological entities as tracheobronchomalacia and excessive dynamic airway collapse (EDAC). Although the exact cause is unknown, chronic obstructive pulmonary disease (COPD) is frequently accompanied by ECAC. Although there are various publications on the relationship between COPD and ECAC, there are very few data for stent placement in patients with tracheobronchomalacia accompanied severe COPD. We share our results for stenting in ECAC among patients with severe COPD. The data in this case series were collected retrospectively. The ECAC diagnosis was made during flexible bronchoscopy with severe COPD. Silicone Y-stents were placed via rigid bronchoscopy under general anesthesia. A total of 9 patients' (7 men) data were evaluated with an average age of 67±10.73 years. One patient experienced stent migration on the second day of stenting prompting stent removal. Another patient died 1 month after stenting. Consequently, we evaluated the follow-up data of remaining 7 patients. The changes in forced expiratory volume 1 was not significant for these 7 cases (P=0.51). The modified Medical Research Council (mMRC) score improvement was statistically significant (P=0.03). Functional status improvement was observed in 4 of 7 patients. Of the 7 patients, mean additional follow-up bronchoscopic interventions requirement was 2.2 times. Our study showed significant decrease in mMRC score with stenting for ECAC in severe COPD. For 2 patients, we experienced severe complications during short-term follow-up period after stenting. Additional follow-up bronchoscopic interventions were required.
Adamson, Douglas; Blazeby, Jane; Nelson, Annmarie; Hurt, Chris; Nixon, Lisette; Fitzgibbon, Jim; Crosby, Tom; Staffurth, John; Evans, Mim; Kelly, Noreen Hopewell; Cohen, David; Griffiths, Gareth; Byrne, Anthony
2014-10-22
The single most distressing symptom for patients with advanced esophageal cancer is dysphagia. Amongst the more effective treatments for relief of dysphagia is insertion of a self-expanding metal stent (SEMS). It is possible that the addition of a palliative dose of external beam radiotherapy may prolong the relief of dysphagia and provide additional survival benefit. The ROCS trial will assess the effect of adding palliative radiotherapy after esophageal stent insertion. The study is a randomized multicenter phase III trial, with an internal pilot phase, comparing stent alone versus stent plus palliative radiotherapy in patients with incurable esophageal cancer. Eligible participants are those with advanced esophageal cancer who are in need of stent insertion for primary management of dysphagia. Radiotherapy will be administered as 20 Gray (Gy) in five fractions over one week or 30 Gy in 10 fractions over two weeks, within four weeks of stent insertion. The internal pilot will assess rates and methods of recruitment; pre-agreed criteria will determine progression to the main trial. In total, 496 patients will be randomized in a 1:1 ratio with follow up until death. The primary outcome is time to progression of patient-reported dysphagia. Secondary outcomes include survival, toxicity, health resource utilization, and quality of life. An embedded qualitative study will explore the feasibility of patient recruitment by examining patients' motivations for involvement and their experiences of consent and recruitment, including reasons for not consenting. It will also explore patients' experiences of each trial arm. The ROCS study will be a challenging trial studying palliation in patients with a poor prognosis. The internal pilot design will optimize methods for recruitment and data collection to ensure that the main trial is completed on time. As a pragmatic trial, study strengths include collection of all follow-up data in the usual place of care, and a focus on patient-reported, rather than disease-orientated, outcomes. Exploration of patient experience and health economic analyses will be integral to the assessment of benefit for patients and the NHS. The trial was registered with Current Controlled Trials (registration number: ISRCTN12376468) on 10 July 2012.
El-Assmy, Ahmed; El-Nahas, Ahmed R; Sheir, Khaled Z
2006-11-01
We performed a prospective, randomized clinical trial to evaluate the outcome of ureteral stents for solitary ureteral stones 2 cm or less in moderately or severely obstructed systems using shock wave lithotripsy. Between 2001 and 2004, 186 patients who met study criteria were randomized into 2 groups. Group 1 received a pre-shock wave lithotripsy 6Fr Double-J stent and group 2 had no stent. Patients were treated with a Dornier MFL 5000 lithotripter. Results were compared in terms of clearance rates, number of shock waves and sessions, irritative voiding symptoms, incidence of complications and secondary interventions. Failure was defined as the need for additional procedure(s) for stone extraction. Overall 164 patients (88.2%) became stone-free after shock wave lithotripsy. Complete stone fragmentation was achieved after 1 to 3 and more than 3 session in 108 (58.1%), 30 (16.1%), 13 (7%) and 14 patients (7.5%), respectively. Ureteral stent insertion did not affect the stone-free rate, which was 84.9% and 91.4% in groups 1 and 2, respectively (p = 0.25). There was no statistical difference in the re-treatment rate, flank pain or temperature in the 2 groups. However, all patients in the stented group significantly complained of side effects attributable to the stent, including dysuria, suprapubic pain, hematuria, pyuria and positive urinary culture. Pretreatment stenting provides no advantage over in situ shock wave lithotripsy for significantly obstructing ureteral calculi. Shock wave lithotripsy is reasonable initial therapy for ureteral stones 2 cm or less that cause moderate or severe hydronephrosis.
Stern, Gretchen; Rimsans, Jessica; Qamar, Arman; Vaduganathan, Muthiah; Bhatt, Deepak L
2018-03-13
Oral antiplatelet therapy may require interruption soon after percutaneous coronary intervention (PCI) or acute coronary syndrome. The optimal parenteral antiplatelet bridge strategy with glycoprotein IIb/IIIa inhibitors or cangrelor, a P2Y12 inhibitor, is unclear. We explore real-world use of cangrelor or eptifibatide for antiplatelet bridging at a large tertiary-care center. Thirty-one patients (9 eptifibatide, 20 cangrelor, and 2 both) received bridge therapy from October 2015 to June 2017. Primary bridge therapy indications included surgery (68%), limited enteral access/absorption (16%), and high-perceived bleed risk (16%). Median duration of bridge therapy was 61 (20-100) hours for cangrelor and 83 (19-98) hours for eptifibatide. Severe/life-threatening bleeding or stent thrombosis was not observed. GUSTO-defined bleeding occurred in 30% (cangrelor) and 27% (eptifibatide). Initial dosing errors occurred in 23% of patients. Death during hospitalization occurred in 16% of patients. Parenteral antiplatelet bridging was used for ~3 days in this single-center, tertiary care experience, commonly for unplanned surgery following PCI. Despite high-risk presentations with >15% in-hospital mortality, efficacy profiles were reassuring with no identified stent thrombosis, but bleeding and dosing errors were common. Antiplatelet bridging should only be used in well-selected patients at the appropriate dose for the minimal necessary duration.
Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N; Zarogoulidis, Paul; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos
2012-11-01
Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2(nd) patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are associated with minimal granulation. In benign post-tracheostomy stenosis silicone stenting appeared safe and effective in re-stenosis after surgery and multiple bronchoscopic interventions, and in long stenosis, involving the lower posterior subglottic larynx in the presence on inflammation and poor neurological status.
Janjic, Milka; Pappa, Foteini; Karagkiozaki, Varvara; Gitas, Christakis; Ktenidis, Kiriakos; Logothetidis, Stergios
2017-01-01
This study describes the development of drug-loaded nanofibrous scaffolds as a nanocoating for endovascular stents for the local and sustained delivery of rosuvastatin (Ros) and heparin (Hep) to injured artery walls after endovascular procedures via the electrospinning process. The proposed hybrid covered stents can promote re-endothelialization; improve endothelial function; reduce inflammatory reaction; inhibit neointimal hyperplasia of the injured artery wall, due to well-known pleiotropic actions of Ros; and prevent adverse events such as in-stent restenosis (ISR) and stent thrombosis (ST), through the antithrombotic action of Hep. Biodegradable nanofibers were prepared by dissolving cellulose acetate (AC) and Ros in N , N -dimethylacetamide (DMAc) and acetone-based solvents. The polymeric solution was electrospun (e-spun) into drug-loaded AC nanofibers onto three different commercially available stents (Co-Cr stent, Ni-Ti stent, and stainless steel stent), resulting in nonwoven matrices of submicron-sized fibers. Accordingly, Hep solution was further used for fibrous coating onto the engineered Ros-loaded stent. The functional encapsulation of Ros and Hep drugs into polymeric scaffolds further underwent physicochemical analysis. Morphological characterization took place via scanning electron microscopy (SEM) and atomic force microscopy (AFM) analyses, while scaffolds' wettability properties were obtained by contact angle (CA) measurements. The morphology of the drug-loaded AC nanofibers was smooth, with an average diameter of 200-800 nm, and after CA measurement, we concluded to the superhydrophobic nature of the engineered scaffolds. In vitro release rates of the pharmaceutical drugs were determined using a high-performance liquid chromatography assay, which showed that after the initial burst, drug release was controlled slowly by the degradation of the polymeric materials. These results imply that AC nanofibers encapsulated with Ros and Hep drugs have great potential in the development of endovascular grafts with anti-thrombogenic properties that can accelerate the re-endothelialization, reduce the neointimal hyperplasia and inflammatory reaction, and improve the endothelial function.
Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N.; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos
2012-01-01
Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2nd patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are associated with minimal granulation. In benign post-tracheostomy stenosis silicone stenting appeared safe and effective in re-stenosis after surgery and multiple bronchoscopic interventions, and in long stenosis, involving the lower posterior subglottic larynx in the presence on inflammation and poor neurological status. PMID:23304439
2012-01-01
Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS) and plastic stents (PS).We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS), functional success (FS), early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III). Results The initial stent insertion was successful in 450 (93.8%) patients. TS was achieved in 204 (88.3%) patients treated with PS and in 246 (98.8%) patients palliated with SEMS (p < 0.001). In the intention-to-treat (ITT) analysis, the FS in patients treated with SEMS (97.9%) was significantly higher than in patients treated with PS (84.8%) (p < 0.001). Late complications occurred in 115 (56.4%) patients treated with PS and 60 (24.4%) patients treated with SEMS (p < 0.001). The median duration of stent patency in weeks (w) were as follows: 20 w in patients palliated with PS and 27 w in patients treated with SEMS (p < 0.0001). In Group 2, the median duration of PS patency was 17 w and 18 w for unilateral and bilateral placement, respectively (p = 0.0004); the median duration of SEMS patency was 24 w and 29 w for unilateral and bilateral placement, respectively (p < 0.0001). Multivariate analysis using the Poisson regression showed that SEMS placement (B = 0.48; P < 0.01) and bilateral deployment (B = 0.24; P < 0.01) were the only independent prognostic factors associated with stent patency. Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients. PMID:22873816
Repici, A; Pagano, N; Rando, G; Carlino, A; Vitetta, E; Ferrara, E; Strangio, G; Zullo, A; Hassan, C
2013-07-01
Benign colorectal strictures are treated conventionally by endoscopic dilation. Experience using SEMS for benign colonic strictures is limited, and outcomes to date have been disappointing. Refractory colorectal strictures remain challenging to be treated with surgery. Polydioxanone-based stent are biodegradable (BD) stent CE approved for esophageal strictures. This study was designed to investigate retrospectively the safety and the efficacy of these stents for the management of strictures refractory to multiple sessions of dilation. Patients with postsurgical benign strictures located within 20 cm from anal verge, refractory to mechanical or pneumatic dilation (at least 3 sessions) were included in this analysis. Clinical success was defined as the absence of occlusive symptoms and the ability to pass through the stricture with a regular size colonoscope. All patients were predilated before stent placement. Stents were released under fluoroscopic control. All patients were under stool softeners for 3 months. Follow-up was scheduled with endoscopic and fluoroscopic controls within 90 days from stent deployment and afterwards by telephone interview and/or ambulatory consultation. Eleven patients (7 males, mean age 62.3 ± 8.5 years) were included. Technical success was achieved in all the patients. Stent migration was observed in four patients within the first 2 weeks after stent placement. Stent migration was followed by recurrence of stricture and obstructive symptoms in all the cases. Among the seven patients who completed the process of stent biodegradation, five of them had complete resolution of the stricture and relief of symptoms. Two of 11 patients required surgical treatment during the follow-up period (mean 19.8 (range 42-15) months). The overall success rate of the BD stent was 45 %. This retrospective analysis of a limited number of patients demonstrated that nondedicated esophageal BD stents are associated with high risk of migration and clinical success in less than 50 % of patients. Dedicated stents with large diameter and antimigration findings could potentially improve the outcome of patients with refractory benign colorectal strictures.
The role of airway stenting in pediatric tracheobronchial obstruction.
Antón-Pacheco, Juan L; Cabezalí, Daniel; Tejedor, Raquel; López, María; Luna, Carmen; Comas, Juan V; de Miguel, Eduardo
2008-06-01
Tracheobronchial obstruction is infrequent in the pediatric age group but it is associated with significant morbidity and mortality. The purpose of this study is to review the results of a single institution experience with endoscopic stent placement in children with benign tracheobronchial obstruction, and with special concern on safety and clinical effectiveness. Twenty-one patients with severe airway stenosing disease in which stent placement was performed between 1993 and 2006. Inclusion criteria according to the clinical status were: failure to wean from ventilation, episode of apnea, frequent respiratory infections (>3 pneumonia/year), and severe respiratory distress. Additional criteria for stent placement were: failure of surgical treatment, bronchomalacia, and tracheomalacia refractory to previous tracheostomy. Selection of the type of stent depended on the site of the lesion, the patient's age, and the stent availability when time of presentation. The following variables were retrospectively evaluated: age, type of obstruction, associated malformations, stent properties, technical and clinical success, complications and related reinterventions, outcome and follow-up period. Thirty-three stents were placed in the trachea (n=18) and/or bronchi (n=15) of 21 patients with a median age of 6 months (range, 9 days-19 years). Etiology of the airway obstruction included severe tracheomalacia and/or bronchomalacia in 19 cases (90%), and postoperative tracheal stenosis in two. Twelve children had a total of 20 balloon-expandable metallic stents placed, and 10 had 13 silicone-type stents (one patient had both). In nine patients (42%) more than one device was placed. Stent positioning was technically successful in all but one patient. Clinical improvement was observed in 18 patients (85%) but complications occurred in five of them (27%). Eight patients died during follow-up but only in one case it was related to airway stenting. Thirteen patients (62%) are alive and in good condition with a mean follow-up of 39 months (1-13.8 years). Although the results were based on a small series, placement of stents in the pediatric airway to treat tracheobronchial obstruction seems to be safe and effective. Stenting is a satisfactory therapeutic option when other procedures have failed or are not indicated.
NASA Astrophysics Data System (ADS)
Winn, Bradley Huegh
Cardiovascular disease is the leading cause of mortality in The United States and Europe, accounting for approximately half of all deaths. The most common form of cardiovascular disease is atherosclerosis, which is characterized by the formation of fatty atheromatous plaques that can grow to occlude the vessel lumen, thus causing ischemia distal to the occlusion. This is commonly treated using balloon angioplasty, which is usually done in conjunction with the deployment of a stent. Stent deployment helps hold the vessel open following the local injury caused by balloon inflation and prevents elastic recoil and subsequent negative remodeling. Stenting has been shown to significantly reduce restenosis rates from approximately 20-50% without a stent to about 10-30% with stent deployment. However, restenosis still remains the main cause of long-term stent failure. In basic terms, a balloon angioplasty procedure is a forceful displacement of an atherosclerotic lesion serving to widen the vessel lumen to increase blood flow. This procedure causes stretching of the vessel wall, tears in the atherosclerotic plaques, and general damage to the vessel in turn signaling a complex cascade of thrombosis, inflammation, intimal thickening, and vascular remodeling. Stent deployment also further complicates the immunological response by triggering a foreign body response from the implantation of a biomaterial into the body. When performing an angioplasty procedure, particularly in conjunction with stent deployment, a certain degree of vascular injury is inevitable. However, the initial injury can be further complicated by the body's local reaction to the implanted biomaterial, the severity of which can ultimately dictate the degree of restenosis and subsequently affect procedural success. The proliferative response of VSMCs to the various afore mentioned stimuli results in the formation of often copious amounts of neointimal tissue, generally known as intimal hyperplasia. The formation of this new tissue, primarily consisting of VSMCs of the synthetic phenotype and their subsequent extracellular matrix, is the sole causation of in-stent restenosis since the stent serves to prevent elastic recoil and negative remodeling. This doctoral research program is focused on endovascular stent biomaterials science and engineering. Overall, this doctoral project is founded on the hypothesis that smooth muscle cell hyperplasia, as an important causative factor for vascular restenosis following endovascular stent deployment, is triggered by the various effects of stent strut contact on the vessel wall including contact forces and material biocompatibility. In this program, a dynamic in vitro model of a stented blood vessel aimed at evaluating the effect of stent strut material selection, and surface coating on smooth muscle cell response was developed. The in vitro stented artery model was validated through the proliferation of VSMC in contact with stent struts. Additionally, it was demonstrated that, with respect to known biocompatible materials such as Nitinol and 316L stainless steel, DNA synthesis and alpha-actin expression, as indicators of VSMC phenotype, are independent of stent material composition. Furthermore, hydroxyapatite was shown to be a biocompatible stent surface coating with acceptable post-strain integrity. This coating was shown in a feasibility study to be capable of serving as a favorable drug delivery platform able to reliably deliver locally therapeutic doses of bisphosphonates, such as alendronate, to control VSMC proliferation in an in vitro model of a stented blood vessel. This stent coating/drug combination may be effective for reducing restenosis as a result of VSMC hyperplasia in vivo.
Gu, Xinzhu; Mao, Zhongwei; Ye, Sang-Ho; Koo, Youngmi; Yun, Yeoheung; Tiasha, Tarannum R; Shanov, Vesselin; Wagner, William R
2016-08-01
Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents. Copyright © 2016 Elsevier B.V. All rights reserved.
Duan, Xu-Hua; Wang, Yan-Li; Han, Xin-Wei; Ren, Jian-Zhuang; Li, Teng-Fei; Zhang, Jian-Hao; Zhang, Kai; Chen, Peng-Fei
2015-01-01
Objectives To determine the safety and feasibility of intraductal radiofrequency ablation (RFA) followed by locoregional tumor treatments in patients with non-resectable malignant biliary obstruction and stent re-occlusion. Methods Fourteen patients with malignant biliary obstruction and blocked metal stents were studied retrospectively. All had intraductal RFA followed by locoregional tumor treatments and were monitored clinically and radiologically. The practicality, safety, postoperative complications, jaundice remission, stent patency and survival time were analyzed. Results Combination treatment was successful for all patients. There were no severe complications during RFA or local treatments. All patients had stent patency restored, with a decline in serum bilirubin. Three patients had recurrent jaundice by 195, 237 and 357 days; two patients underwent repeat intraductal RFA; and one required an internal-external biliary drain. The average stent patency time was 234 days (range 187-544 days). With a median follow-up of 384 days (range 187-544 days), six patients were alive, while eight had died. There was no mortality at 30 days. The 3, 6, 12 and 18 month survival rates were 100%, 100%, 64.3% and 42.9%, respectively. Conclusion Intraductal RFA followed by locoregional tumor treatments for occluded metal stents is safe and practically feasible and potential increase stent patency and survival times. PMID:26244367
Al-Marhoon, Mohammed S; Shareef, Omar; Venkiteswaran, Krishna P
2012-12-01
To determine the factors affecting the development of complications and the outcomes of JJ stenting. The study included 220 patients (133 males and 87 females, mean age 39.5 years, SD 15.4) who had self-retaining JJ ureteric stents placed while in the authors' institution. Univariate and multivariate analyses were used to identify the significant variables affecting the development of complications and outcome of stenting (condition 'improved' or 'not improved'). Using a modified Clavien classification, there were grade I, II, IIIa, IIIb complications in 67 (30.4%), 39 (17.7%), two (0.9%) and 23 (10.5%) patients, respectively, and none of grades IVa, IVb and V. Loin pain (10.9%) and urinary tract infection (10.9%) were the most common complications, followed by dysuria (7.7%). There were significant complications requiring treatment in 29% of patients, and 71.4% of patients improved after stenting. On multivariate analysis the significant independent factor affecting the complication rate was the stent length (P = 0.016), and the significant independent factor affecting the 'improved' outcome was age (P = 0.014). Longer stents are associated with increased complication rates, and the older the patient the more likely they are to have a poor outcome after stenting. Future prospective multicentre studies with more patients are needed to confirm the present conclusions.
Chung, Joonho; Matsuda, Yoshikazu; Nelson, Jessica; Keigher, Kiffon; Lopes, Demetrius K
2018-01-01
Objectives The Low-profile Visualized Intraluminal Support (LVIS) device is a flexible intracranial stent. The first generation of this system had significant challenges in consistently providing good wall apposition and aneurysm neck coverage. A new modified LVIS, LVIS Blue (Blue), has been developed to address these issues. The purpose of this study is to report a laboratory comparison of wall apposition and aneurysm neck coverage between the original LVIS and Blue. Methods In bench-top experiments, we noted the visual appearance of the devices and evaluated changes in stent cell angles, neck coverage surface area (%), and stent cell crossing profile for microcatheters using a fusiform aneurysm model. Our in vitro experiments included evaluation of wall apposition and aneurysm neck coverage of the devices under direct radiographic visualization. Results Blue showed three definite different zones (a mid-zone, a high-density zone, and a transitional zone) and higher metal coverage in the straight fusiform aneurysm model compared to LVIS. Two commercially available microcatheters easily crossed the stent cell at the greater curvature for both devices. In in vitro experiments, Blue showed better wall apposition in tortuous arteries and achieved higher neck coverage in the bifurcation aneurysm compared to LVIS. Discussion Blue achieved better wall apposition in tortuous arteries and higher aneurysm neck coverage (higher metal-to-artery ratio) in bifurcation aneurysms than LVIS. Our results may provide informative physical properties of LVIS and Blue to be expected when those are used for stent-assisted coil embolization of a large-giant fusiform aneurysm or a bifurcation saccular aneurysm clinically.
Coelho, Andreia; Lobo, Miguel; Gouveia, Ricardo; Silveira, Diogo; Campos, Jacinta; Augusto, Rita; Coelho, Nuno; Canedo, Alexandra
2018-01-23
Endovascular intracranial thrombectomy (IT) has established itself as the standard of care in treating large-vessel anterior circulation acute ischemic stroke (AIS). However, internal carotid artery (ICA) stenosis/occlusion hampers distal access and controversy about simultaneous emergency ICA stenting ensues. The purpose of this review was to evaluate the safety of emergency ICA stenting in combination with IT for AIS with tandem occlusions. To our knowledge this is the first meta-analysis to evaluate emergency ICA stenting in tandem occlusions, combining results from studies with a control group. A systematic review and meta-analysis was conducted according to the recommendations of the Preferred Reporting Items for Systematic reviews and Meta- Analyses (PRISMA) statement. A total of 649 potentially relevant articles were initially selected. After reviewing at title or abstract level, 87 articles were read in full and 23 were included. These studies recruited 1000 patients, 220 submitted to IT with no emergency ICA stenting and 780 to IT and emergency ICA stenting. Successful revascularization (Thrombolysis in cerebral infarction scale - TICI≥2b) was achieved in 48.6-100%. Good outcome (modified Rankin scale - mRS≤2) ranged from 18.2-100%. Symptomatic intracranial haemorrhage (sICH) ranged from 0-45.7% (overall n=168; 17.2%). Mortality at 90 days ranged from 0-45.4% (overall n=114; 11.7%). Time to recanalization was significantly longer in the stenting group with an overall mean difference of 1.76 (95% Confidence Interval: 1.59-1.93). In this meta-analysis time to recanalization was significantly longer in the emergency ICA stenting group. There was no benefit from emergency stenting in parameters such as successful revascularization (TICI≥2b), clinical outcome (mRS≤2) or 90-day mortality. Data on sICH were scarce. Emergency ICA stenting appears to increase time to revascularization and increase the risk of complications with no demonstrated clinical benefit. Furthermore, no prospective, randomized controlled trials demonstrating relative efficacy and safety of concomitant ICA stenting have been published to date. Additional studies must be undertaken to define the role of angioplasty and stenting of the extracranial carotid arteries in the early management of acute stroke in tandem occlusions. Until then, we recommend that ICA stenting concommintant to thrombectomy in acute stroke patients should be avoided.
NASA Astrophysics Data System (ADS)
Reece, Lisa M.
Aneurysms are pockets of blood that collect outside blood vessel walls forming dilatations and leaving arterial walls very prone to rupture. Current treatments include: (1) clipping, and (2) coil embolization, including stent-assisted coiling. While these procedures can be effective, it would be advantageous to design a biologically active stent, modified with magnetic stent coatings, allowing cells to be manipulated to heal the arterial lining. Further, velocity, pressure, and wall shear stresses aid in the disease development of aneurysmal growth, but the shear force mechanisms effecting wound closure is elusive. Due to these factors, there is a definite need to cultivate a new stent device that will aid in healing an aneurysm in situ. To this end, a static bioactive stent device was synthesized. Additionally, to study aneurysm pathogenesis, a lab-on-a-chip device (a dynamic stent device) is the key to discovering the underlying mechanisms of these lesions. A first step to the reality of a true bioactive stent involves the study of cells that can be tested against the biomaterials that constitute the stent itself. The second step is to test particles/cells in a microfluidic environment. Therefore, biocompatability data was collected against PDMS, bacterial nanocellulose (BNC), and magnetic bacterial nanocellulose (MBNC). Preliminary static bioactive stents were synthesized whereby BNC was grown to cover standard nitinol stents. In an offshoot of the original research, a two-dimensional microfluidic model, the Aneurysm-on-a-ChipTM (AOC), was the logical answer to study particle flow within an aneurysm "sac" - this was the dynamic bioactive stent device. The AOC apparatus can track particles/cells when it is coupled to a particle image velocimetry software (PIV) package. The AOC fluid flow was visualized using standard microscopy techniques with commercial microparticles/cells. Movies were taken during fluid flow experiments and PIV was utilized to monitor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr
To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less
Suárez, Javier; Jimenez-Pérez, Javier
2016-01-01
Obstructive symptoms are present in 8% of cases at the time of initial diagnosis in cases of colorectal cancer. Emergency surgery has been classically considered the treatment of choice in these patients. However, in the majority of studies, emergency colorectal surgery is burdened with higher morbidity and mortality rates than elective surgery, and many patients require temporal colostomy which deteriorates their quality of life and becomes permanent in 10%-40% of cases. The aim of stenting by-pass to surgery is to transform emergency surgery into elective surgery in order to improve surgical results, obtain an accurate tumoral staging and detection of synchronous lesions, stabilization of comorbidities and performance of laparoscopic surgery. Immediate results were more favourable in patients who were stented concerning primary anastomosis, permanent stoma, wound infection and overall morbidity, having the higher surgical risk patients the greater benefit. However, some findings laid out the possible implication of stenting in long-term results of oncologic treatment. Perforation after stenting is related to tumoral recurrence. In studies with perforation rates above 8%, higher recurrences rates in young patients and lower disease free survival have been shown. On the other hand, after stenting the number of removed lymph nodes in the surgical specimen is larger, patients can receive adjuvant chemotherapy earlier and in a greater percentage and the number of patients who can be surgically treated with laparoscopic surgery is larger. Finally, there are no consistent studies able to demonstrate that one strategy is superior to the other in terms of oncologic benefits. At present, it would seem wise to assume a higher initial complication rate in young patients without relevant comorbidities and to accept the risk of local recurrence in old patients (> 70 years) or with high surgical risk (ASA III/IV). PMID:26798441
NASA Astrophysics Data System (ADS)
Koenrades, Maaike A.; Struijs, Ella M.; Klein, Almar; Kuipers, Henny; Geelkerken, Robert H.; Slump, Cornelis H.
2017-03-01
The application of endovascular aortic aneurysm repair has expanded over the last decade. However, the long-term performance of stent grafts, in particular durable fixation and sealing to the aortic wall, remains the main concern of this treatment. The sealing and fixation are challenged at every heartbeat due to downward and radial pulsatile forces. Yet knowledge on cardiac-induced dynamics of implanted stent grafts is sparse, as it is not measured in routine clinical follow-up. Such knowledge is particularly relevant to perform fatigue tests, to predict failure in the individual patient and to improve stent graft designs. Using a physical dynamic stent graft model in an anthropomorphic phantom, we have evaluated the performance of our previously proposed segmentation and registration algorithm to detect periodic motion of stent grafts on ECG-gated (3D+t) CT data. Abdominal aortic motion profiles were simulated in two series of Gaussian based patterns with different amplitudes and frequencies. Experiments were performed on a 64-slice CT scanner with a helical scan protocol and retrospective gating. Motion patterns as estimated by our algorithm were compared to motion patterns obtained from optical camera recordings of the physical stent graft model in motion. Absolute errors of the patterns' amplitude were smaller than 0.28 mm. Even the motion pattern with an amplitude of 0.23 mm was measured, although the amplitude of motion was overestimated by the algorithm with 43%. We conclude that the algorithm performs well for measurement of stent graft motion in the mm and sub-mm range. This ultimately is expected to aid in patient-specific risk assessment and improving stent graft designs.
Kajbafzadeh, Abdol-Mohammad; Zeinoddini, Atefeh; Ebadi, Maryam; Heidari, Reza; Tajalli, Afshin
2014-04-01
The purpose of the study is to describe our experience with the application of externalized double-J ureteral stent (DJUS) during pyeloplasty for correction of ureteropelvic junction obstruction (UPJO) in order to avoid cystoscopy for stent removal. Pyeloplasty was performed in 523 infants with UPJO using miniature pyeloplasty technique. After removing the obstructed segment, a 3-Fr. DJUS was placed into the ureter. In order to avoid cystoscopy for the removal of the stent, a feeding tube was passed through the skin and renal pelvis via a separate stab incision, connected to the DJUS and secured to the external body surface (skin), and the pyeloplasty was completed. The feeding tube along with the stent was removed after 3-4 weeks, respectively. Postoperative follow-up visits were performed 1, 3, and 6 months after the procedure. The mean operative time was 49 min (range 41-79). Patients were discharged after 17 ± 2 h (mean ± SD). No patient experienced bladder spasm or anticholinergic administration. Forty-four patients (8.4 %) experienced minor complications including non-febrile urinary tract infections and mild hematuria. No major complication including urinoma, leakage, and stent migration or displacement was observed during the follow-up period. Stent removal was tolerated by 99.8 % of patients in an outpatient setting with minimal discomfort without performing cystoscopy. Using external DJUS along with a pyelocutaneous stent extension during pyeloplasty is a safe, feasible, and beneficial technique. This technique resulted in high success rate with minimal cost and no renal injury. The non-cystoscopic stent removal and elimination of urethral catheterization following pyeloplasty are the other advantages of this technique.
Ahmed, Waqar Habib; Zambahari, Robaayah; Al-Rashdan, Ibrahim; Al Naeemi, Abdullah; Saeed, Fuad A; Mascioli, Stephen
2008-12-01
The Taxus Olympia registry is a prospective, postapproval registry collecting clinical outcomes data on patients receiving the Taxus Liberté paclitaxel-eluting stent during routine interventional cardiology practice. Between February and July 2005, 529 patients receiving the Taxus Liberté stent at 16 centers in the Middle East, South/Central America, and Asia/Pacific regions were enrolled in Phase I of Olympia. The primary end-point was Taxus Liberté stent-related cardiac events (cardiac death, MI, and revascularization) at 30 days postimplant. Additional clinical assessment was conducted at 6 and 12 months. Olympia phases II and III are in clinical follow-up and will be reported separately. One-year clinical follow-up is available for 98% of patients. Complex patients and lesions were prevalent, including: 50% diabetes mellitus, 49% multivessel disease, 30% multiple stenting, 48% AHA/ACC type B2/C lesions, 19% long lesions (>26 mm), and 40% small vessels (
Kim, Kun Yung; Park, Jung-Hoon; Kim, Do Hoon; Tsauo, Jiaywei; Kim, Min Tae; Son, Woo-Chan; Kang, Sung-Gwon; Kim, Dong-Hyun; Song, Ho-Young
2018-01-01
Purpose To investigate the use of sirolimus-eluting biodegradable stents (SEBSs) to suppress granulation tissue formation after stent placement in a rat urethral model. Materials and Methods All experiments were approved by the animal research committee. A total of 36 male Sprague-Dawley rats were randomized into three equal groups after biodegradable stent placement. Group A received control biodegradable stents. Groups B and C received stents coated with 90 µg/cm 2 and 450 µg/cm 2 sirolimus, respectively. Six rats in each group were sacrificed after 4 weeks; the remaining rats were sacrificed after 12 weeks. The therapeutic effectiveness of SEBSs was assessed by comparing the results of retrograde urethrography and histologic examination. Analysis of variance with post hoc comparisons was used to evaluate statistical differences. Results SEBS placement was technically successful in all rats. Urethrographic and histologic examinations revealed significantly less granulation tissue formation at both time points in the rats receiving SEBSs (groups B and C) compared with those that received control stents (group A) (P < .05 for all). There were no significant differences in urethrographic and histologic findings between groups B and C (P > .05 for all). However, the mean number of epithelial layers in group B was higher than that in group C at 4 weeks after stent placement (P < .001). Apoptosis increased in group C compared with groups A and B (P < .05 for all). Conclusion The use of SEBSs suppressed granulation tissue formation secondary to stent placement in a rat urethral model; local therapy with SEBSs may be used to decrease stent-related granulation tissue formation. © RSNA, 2017.
Majid, Adnan; Alape, Daniel; Kheir, Fayez; Folch, Erik; Ochoa, Sebastian; Folch, Alejandro; Gangadharan, Sidhu P
2016-01-01
Patients with severe symptomatic expiratory central airway collapse (ECAC) undergo a stent trial to determine whether they are candidate for tracheobronchoplasty. Most stent trials were done using silicone stents. However, there was a higher number of silicone stent-related complications. The aim of this study was to evaluate the safety and efficacy of short-term uncovered self-expanding metallic airway stents (USEMAS) in patients with ECAC. This was a retrospective review. Baseline measurements were compared to those obtained after 7-14 days. Measurements included: Modified Medical Research Council (mMRC), Cough Quality of Life Questionnaire (CQLQ), spirometry testing, and 6-Minute Walk Test (6MWT). Stent- and procedure-related complications were reported. 33 patients (median age, 52 years) underwent the USEMAS trial. Presenting symptoms were dyspnea in 100%, intractable cough in 90.3%, recurrent infection in 42.2%, and inability to clear secretions in 21.4%. Dyspnea, cough, and secretion clearance improved in 88, 70, and 57%, respectively. Overall, there was a significant improvement in mMRC (p < 0.001), CQLQ (p = 0.015), and 6MWT (p = 0.015). There was 1 airway infection, 1 stent migration, and 1 pneumothorax. The median duration of USEMAS was 7 days. All stents were removed without any complications. At the time of stent removal, no granulation tissue was observed in 30.9%, and mild granulation tissue was observed in 69.1%. The short-term USEMAS trial improves respiratory symptoms, quality of life, and exercise capacity with few complications in patients with severe symptomatic ECAC when performed by a multidisciplinary airway team in highly specialized centers with experience in the evaluation and treatment of this patient population. © 2016 S. Karger AG, Basel.
Ji, Woong Bae; Kwak, Jung Myun; Kang, Dong Woo; Kwak, Han Deok; Um, Jun Won; Lee, Sun-Il; Min, Byung-Wook; Sung, Nak Song; Kim, Jin; Kim, Seon Hahn
2017-01-01
The efficacy of stenting for right-sided malignant colonic obstruction is unknown. This study aimed to evaluate the safety, feasibility, and clinical benefits of self-expandable metallic stent insertion for right-sided malignant colonic obstruction. Clinical data from patients who underwent right hemicolectomy for right colon cancer from January 2006 to July 2014 at three Korea University hospitals were retrospectively reviewed. A total of 39 patients who developed malignant obstruction in the right-sided colon were identified, and their data were analyzed. Stent insertion was attempted in 16 patients, and initial technical success was achieved in 14 patients (87.5 %). No stent-related immediate complications were reported. Complete relief from obstruction was achieved in all 14 patients. Twenty-five patients, including two patients who failed stenting, underwent emergency surgery. In the stent group, 93 % (13/14) of patients underwent elective laparoscopic surgery, and only one surgery was converted to an open procedure. All patients in the emergency group underwent emergency surgery within 24 h of admission. In the emergency group, only 12 % (3/25) of patients underwent laparoscopic surgery, with one surgery converted to an open procedure. All patients in both groups underwent either laparoscopy-assisted or open right/extended right hemicolectomy with primary anastomoses as the first operation. The operative times, retrieved lymph nodes, and pathologic stage did not differ between the two groups. Postoperative hospital stay (9.4 ± 3.4 days in the stent group vs. 12.4 ± 5.9 in the emergency group, p = 0.089) and time to resume oral food intake (3.2 ± 2.1 days in the stent group vs. 5.7 ± 3.4 in the emergency group, p = 0.019) were shorter in the stent group. And there were no significant differences in disease-free survival and overall survival between the two groups. Stent insertion appears to be safe and feasible in patients with right-sided colonic malignant obstruction. It facilitates minimally invasive surgery and may result in better short-term surgical outcomes.
Mauri, Giovanni; Michelozzi, Caterina; Melchiorre, Fabio; Poretti, Dario; Tramarin, Marco; Pedicini, Vittorio; Solbiati, Luigi; Cornalba, Gianpaolo; Sconfienza, Luca Maria
2013-12-01
To evaluate feasibility, safety, and outcome of patients treated with biodegradable biliary stents for benign biliary stenosis refractory to other treatments. Between March 2011 and September 2012, ten patients (seven men, three women; age 59 ± 7 years) with recurrent cholangitis due to postsurgical biliary stricture, previous multiple unsuccessful (two to five) bilioplasties, and unsuitability for surgical/endoscopic repair underwent percutaneous implantation of a biodegradable biliary stent. Patients were followed-up clinically and with ultrasound at 1, 3 and 6 months, and then at 6-month intervals. Stent implantation was always feasible. No immediate major or minor complications occurred. In all patients, 48-h cholangiographic control demonstrated optimal stent positioning and stenosis resolution. In a median follow-up time of 16.5 months (25th-75th percentiles = 11-20.25 months) no further invasive treatment was needed. Three patients experienced transient episodes of cholangitis. Neither re-stenosis nor dilatation of the biliary tree was documented during follow-up. No stent was visible at the 6-month follow-up. Percutaneous placement of biodegradable biliary stents represents a new option in treating benign biliary stenoses refractory to treatment with bilioplasty. This technique seems to be feasible, effective and free from major complications. Further investigations are warranted to confirm our preliminary results.
Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis
Ocak, Sebahat; Gourdin, Maximilien; d'Odémont, Jean-Paul
2016-01-01
Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea) were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent's tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%), migration (30%), and sputum retention (15%). Fifty-five % of the stents (11/20) had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease. PMID:27777507
Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis.
Dahlqvist, Caroline; Ocak, Sebahat; Gourdin, Maximilien; Dincq, Anne Sophie; Putz, Laurie; d'Odémont, Jean-Paul
2016-01-01
Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea) were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent's tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%), migration (30%), and sputum retention (15%). Fifty-five % of the stents (11/20) had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.
de Jonge, Paul K J D; Sloff, Marije; Janke, Heinz P; Kortmann, Barbara B M; de Gier, Robert P E; Geutjes, Paul J; Oosterwijk, Egbert; Feitz, Wout F J
2017-10-01
It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats. Similarly to a previous study in pigs, the ureteral J-stent was blindly inserted until some resistance was met. During evaluation of the goats after three months, perforation of the renal cortex by the stent was observed in four out of seven animals. These results indicated that blind stent placement was not possible in goats. In four new goats, clinical protocols were followed using X-ray and iodinated contrast fluids to visualize the kidney and stent during stent placement. With this adaptation the stents were successfully placed in the kidneys of these four new goats with minimal additional effort. It is likely that other groups in other fields ran into similar problems that could have been avoided by following clinical protocols. Therefore, we would like to stress the importance of following clinical protocols when using medical devices in animals to prevent unnecessary suffering and to reduce the number of animals needed.
In vitro hemocompatibility and cytocompatibility of dexamethasone-eluting PLGA stent coatings
NASA Astrophysics Data System (ADS)
Zhang, Jiang; Liu, Yang; Luo, Rifang; Chen, Si; Li, Xin; Yuan, Shuheng; Wang, Jin; Huang, Nan
2015-02-01
Drug-eluting stents (DESs) have been an important breakthrough for interventional cardiology applications since 2002. Though successful in reducing restenosis, some adverse clinical problems still emerged, which were mostly caused by the bare-metal stents and non-biodegradable polymer coatings, associated with the delayed endothelialization process. In this study, dexamethasone-loaded poly (lactic-co-glycolic acid) (PLGA) coatings were developed to explore the potential application of dexamethasone-eluting stents. Dexamethasone-eluting PLGA stents were prepared using ultrasonic atomization spray method. For other tests like stability and cytocompatibility and hemocompatibility tests, dexamethasone loaded coatings were deposited on 316L SS wafers. Fourier transform-infrared spectroscopy (FT-IR) results demonstrated that there was no chemical reaction between PLGA and dexamethasone. The balloon expansion experiment and surface morphology observation suggested that the stent coatings were smooth and uniform, and could also withstand the compressive and tensile strains imparted without cracking after stent expansion. The drug release behavior in vitro indicated that dexamethasone existed burst release within 1 day, but it presented linear release characteristics after 6 days. In vitro platelets adhesion, activation test and APTT test were also done, which showed that after blending dexamethasone into PLGA, the hemocompatibility was improved. Besides, dexamethasone and dexamethasone-loaded PLGA coatings could significantly inhibit the attachment and proliferation of smooth muscle cells.
Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán
2017-08-01
Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases.
Son, Donghee; Lee, Jongha; Lee, Dong Jun; Ghaffari, Roozbeh; Yun, Sumin; Kim, Seok Joo; Lee, Ji Eun; Cho, Hye Rim; Yoon, Soonho; Yang, Shixuan; Lee, Seunghyun; Qiao, Shutao; Ling, Daishun; Shin, Sanghun; Song, Jun-Kyul; Kim, Jaemin; Kim, Taeho; Lee, Hakyong; Kim, Jonghoon; Soh, Min; Lee, Nohyun; Hwang, Cheol Seong; Nam, Sangwook; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong
2015-06-23
Implantable endovascular devices such as bare metal, drug eluting, and bioresorbable stents have transformed interventional care by providing continuous structural and mechanical support to many peripheral, neural, and coronary arteries affected by blockage. Although effective in achieving immediate restoration of blood flow, the long-term re-endothelialization and inflammation induced by mechanical stents are difficult to diagnose or treat. Here we present nanomaterial designs and integration strategies for the bioresorbable electronic stent with drug-infused functionalized nanoparticles to enable flow sensing, temperature monitoring, data storage, wireless power/data transmission, inflammation suppression, localized drug delivery, and hyperthermia therapy. In vivo and ex vivo animal experiments as well as in vitro cell studies demonstrate the previously unrecognized potential for bioresorbable electronic implants coupled with bioinert therapeutic nanoparticles in the endovascular system.
[Carotid Stenting in France after the EVA 3S and SPACE publications].
Beyssen, B; Rousseau, H; Bracard, S; Sapoval, M; Gaux, J-C
2007-01-01
Angioplasty of stenoses of the carotid bifurcation is a revascularization procedure that is used successfully in many patients. With more than 10 years of experience now, the feasibility of carotid stenting has been demonstrated. Its distribution is highly variable depending on the country, with a mean penetration rate in Europe of 15% of the number of carotid revascularizations. However, the complication rate is highly variable from one series to another and depends on the type of patient treated and the operator's learning curve. The results of the first two randomized studies comparing endarterectomy and carotid stenting, EVA 3S in France and SPACE in Germany, have just been published. The conclusions of these studies only relate to symptomatic patients, who make up a small proportion of revascularized patients. At 30 days, the French study concluded that surgery was better, and the German study showed no advantage to stenting. The analysis of these results compared to other publications should make it possible to best define the current indications for carotid stenting.
Sun, Xin Rong; Tang, Cheng Wu; Lu, Wen Ming; Xu, Yong Qiang; Feng, Wen Ming; Bao, Yin; Zheng, Yin Yuan
2014-05-01
This study aims to compare the clinical outcomes and costs between endoscopic biliary stenting (EBS) and percutaneous transhepatic biliary stenting (PTBS). We randomly assigned 112 patients with unresectable malignant biliary obstruction 2006 and 2011 to receive EBS or PTBS with self-expandable metal stent (SEMS) as palliative treatment. PTBS was successfully performed in 55 patients who formed the PTBS group (failed in 2 patients). EBS was successfully performed in 52 patients who formed the EBS group (failed in 3 patients). The effectiveness of biliary drainage, hospital stay, complications, cost, survival time and mortality were compared. Patients in PTBS group had shorter hospital stay and lower initial and overall expense than the BBS group (P < 0.05). There was no significant difference in effectiveness of biliary drainage (P = 0.9357) or survival time between two groups (P = 0.6733). Early complications occurred in PTBS group was significantly lower than in EBS group (3/55 vs 11/52, P = 0.0343). Late complications in the EBS group did not differ significantly from PTBS group (7/55 vs 9/52, P = 0.6922). The survival curves in the two groups showed no significant difference (P = 0.5294). Conclusions: 3.
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A
2003-01-01
Objectives: To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Methods: Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). Results: No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Conclusion: Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants. PMID:12748224
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A
2003-06-01
To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants.
Zhang, Fan; Tongo, Nosakhare Douglas; Hastings, Victoria; Kanzali, Parisa; Zhu, Ziqiang; Chadow, Hal; Rafii, Shahrokh E
2017-04-29
BACKGROUND Acute coronary syndrome (ACS) can present with atypical chest pain or symptoms not attributed to heart disease, such as indigestion. Hiccups, a benign and self-limited condition, can become persistent or intractable with overlooked underlying etiology. There are various causes of protracted hiccups, including metabolic abnormalities, psychogenic disorders, malignancy, central nervous system pathology, medications, pulmonary disorders, or gastrointestinal etiologies. It is rarely attributed to cardiac disease. CASE REPORT We report a case of intractable hiccups in a 51-year-old male with cocaine related myocardial infarction (MI) before and after stent placement. Coronary angiogram showed in-stent thrombosis of the initial intervention. Following thrombectomy, balloon angioplasty, and stent, the patient recovered well without additional episodes of hiccups. Although hiccups are not known to present with a predilection for a particular cause of myocardial ischemia, this case may additionally be explained by the sympathomimetic effects of cocaine, which lead to vasoconstriction of coronary arteries. CONCLUSIONS Hiccups associated with cardiac enzyme elevation and EKG ST-segment elevation before and after percutaneous coronary intervention (PCI) maybe a manifestation of acute MI with or without stent. The fact that this patient was a cocaine user may have contributed to the unique presentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrier, Pierre, E-mail: p.barrier@gmail.com; Julien, Auriol; Guillaume, Canevet
2010-04-15
Although percutaneous transluminal renal angioplasty (PTRA) is associated with excellent results in medial fibromuscular dysplasia (FMD), the clinical and technical outcome in the less common nonmedial subtype of FMD is not clearly known. Angiographic PTRA results and clinical follow-up were documented, to report technical and clinical results in 30 patients with unifocal, nonmedial dysplastic stenoses. Balloon angioplasty was technically successful in only 65% of the lesions. Additional stenting, performed after PTRA failure in six patients, increased the initial technical success rate to 82%. Stenting was used in another lesion after restenosis, and long-term patency was achieved in only three ofmore » the seven stented lesions. Frequent restenoses and unusual complications were observed during follow-up. Stent fracture occurred in two cases. Overall, long-term clinical and technical successes were sustained in 70 and 76%, respectively. We conclude that nonmedial, unifocal renal artery dysplastic stenoses do not share the excellent prognosis of the medial type and that stenting should be avoided. Therefore, surgery should be considered in lesions remaining unresponsive to balloon dilatation, after a second PTRA attempt.« less
Automatic three-dimensional registration of intravascular optical coherence tomography images
NASA Astrophysics Data System (ADS)
Ughi, Giovanni J.; Adriaenssens, Tom; Larsson, Matilda; Dubois, Christophe; Sinnaeve, Peter R.; Coosemans, Mark; Desmet, Walter; D'hooge, Jan
2012-02-01
Intravascular optical coherence tomography (IV-OCT) is a catheter-based high-resolution imaging technique able to visualize the inner wall of the coronary arteries and implanted devices in vivo with an axial resolution below 20 μm. IV-OCT is being used in several clinical trials aiming to quantify the vessel response to stent implantation over time. However, stent analysis is currently performed manually and corresponding images taken at different time points are matched through a very labor-intensive and subjective procedure. We present an automated method for the spatial registration of IV-OCT datasets. Stent struts are segmented through consecutive images and three-dimensional models of the stents are created for both datasets to be registered. The two models are initially roughly registered through an automatic initialization procedure and an iterative closest point algorithm is subsequently applied for a more precise registration. To correct for nonuniform rotational distortions (NURDs) and other potential acquisition artifacts, the registration is consecutively refined on a local level. The algorithm was first validated by using an in vitro experimental setup based on a polyvinyl-alcohol gel tubular phantom. Subsequently, an in vivo validation was obtained by exploiting stable vessel landmarks. The mean registration error in vitro was quantified to be 0.14 mm in the longitudinal axis and 7.3-deg mean rotation error. In vivo validation resulted in 0.23 mm in the longitudinal axis and 10.1-deg rotation error. These results indicate that the proposed methodology can be used for automatic registration of in vivo IV-OCT datasets. Such a tool will be indispensable for larger studies on vessel healing pathophysiology and reaction to stent implantation. As such, it will be valuable in testing the performance of new generations of intracoronary devices and new therapeutic drugs.
Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.
Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K
2016-02-01
Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Metallic stents for tracheobronchial pathology treatment.
Serrano, Carolina; Laborda, Alicia; Lozano, Juan M; Caballero, Hugo; Sebastián, Antonio; Lopera, Jorge; de Gregorio, Miguel Ángel
2013-12-01
To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 ± 1.2 months in patients with malignant lesions and 76.2 ± 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.
Our ultrasonographic experience in the management of symptomatic hydronephrosis during pregnancy.
Dell'Atti, Lucio
2016-03-01
The aim of the present study was to document the role of ultrasound in the diagnosis and management of symptomatic hydronephrosis during pregnancy. In this study, we reviewed 36 consecutive cases of pregnant women whose pregnancy was complicated by symptomatic hydronephrosis. In all patients, management was initially conservative (analgesics and fluids) after hospitalization. The following criteria were used to indicate double-J stent placement under US guidance rather than a conservative treatment: persistent pain with no improvement after conservative treatment, progressive hydronephrosis (>2 cm dilatation of the renal pelvis) or presence of uterine contractions. The mean patient's age was 25 years (17-35) and gestational age at clinical presentation was 24 weeks (13-37). 81 % of cases had a renal pelvis dilatation >2 cm, while in only 19 % of cases there was a hydronephrosis between 1 and 2 cm in diameter; however, calculi were confirmed only in 25 patients. 28 patients required an invasive management with double-J stent insertion under US guidance. The sensitivity and specificity of US in the etiological diagnosis of hydronephrosis during pregnancy was 83 and 91 %, respectively. Conservative management with medical therapy and observation should be the first-line treatment approach. In our opinion a rapid ureteral decompression with the insertion of a ureteral double-J stent, under US visualization, is the safest method in the treatment of pregnant women with obstructed renal systems.
Garg, Pankaj Kumar; Jain, Bhupendra Kumar; Pandey, Satya Deo; Rathi, Vinita; Puri, Amarendra Singh
2012-07-01
Simultaneous non-traumatic perforation of the extrahepatic bile duct and the gallbladder is an uncommon occurrence that has been infrequently reported. We describe a patient with a spontaneous perforation of both the extrahepatic bile duct and the gallbladder. A contrast-enhanced computed tomography (CECT) scan of the abdomen and endoscopic retrograde cholangiopancreatography (ERCP) demonstrated a perforation of the gallbladder and a free leak from the right hepatic duct, respectively. Endoscopic biliary drainage following a sphincterotomy and biliary stent placement led to a dramatic improvement in the patient's general condition. He was subsequently scheduled to undergo an elective cholecystectomy. Repeat ERCP performed at 4 weeks after the initial stenting showed a normal cholangiogram and a distally migrated stent, which was there after removed. However, early stent removal led to re-perforation of hepatic duct and gallbladder. A repeat endoscopic biliary drainage did not help, and the patient developed biliary peritonitis. Surgical exploration revealed a perforation at the fundus of the gallbladder, 400 ml of biliopurulent collection and a frozen Calot's triangle. A subtotal cholecystectomy, gall stone removal, and a thorough peritoneal lavage were undertaken. The patient improved postoperatively. The second biliary stent was removed after 4 months. This case report highlights the role of endoscopic biliary drainage in the management of an extrahepatic bile duct perforation and warns against the early removal of a biliary stent.
Zhang, Fan; Tongo, Nosakhare Douglas; Hastings, Victoria; Kanzali, Parisa; Zhu, Ziqiang; Chadow, Hal; Rafii, Shahrokh E.
2017-01-01
Patient: Male, 51 Final Diagnosis: ST-segment elevation myocardial infarction with acute stent thrombosis Symptoms: Chest pain • hiccups Medication: — Clinical Procedure: — Specialty: Cardiology Objective: Unusual clinical course Background: Acute coronary syndrome (ACS) can present with atypical chest pain or symptoms not attributed to heart disease, such as indigestion. Hiccups, a benign and self-limited condition, can become persistent or intractable with overlooked underlying etiology. There are various causes of protracted hiccups, including metabolic abnormalities, psychogenic disorders, malignancy, central nervous system pathology, medications, pulmonary disorders, or gastrointestinal etiologies. It is rarely attributed to cardiac disease. Case Report: We report a case of intractable hiccups in a 51-year-old male with cocaine related myocardial infarction (MI) before and after stent placement. Coronary angiogram showed in-stent thrombosis of the initial intervention. Following thrombectomy, balloon angioplasty, and stent, the patient recovered well without additional episodes of hiccups. Although hiccups are not known to present with a predilection for a particular cause of myocardial ischemia, this case may additionally be explained by the sympathomimetic effects of cocaine, which lead to vasoconstriction of coronary arteries. Conclusions: Hiccups associated with cardiac enzyme elevation and EKG ST-segment elevation before and after percutaneous coronary intervention (PCI) maybe a manifestation of acute MI with or without stent. The fact that this patient was a cocaine user may have contributed to the unique presentation. PMID:28455489
Treatment of acquired nasopharyngeal stenosis using a removable silicone stent.
De Lorenzi, Davide; Bertoncello, Diana; Comastri, Stefano; Bottero, Enrico
2015-02-01
The aim of this prospective study was to characterise patient characteristics and the histories of cats with acquired nasopharyngeal stenosis (ANS), and to describe the use of a removable silicone stent for treatment. ANS was diagnosed in 15 cats with clinical signs present for a median of 4 months. Clinical signs included stertor and inspiratory difficulty, nasal discharge, sneezing, dysphagia, regurgitation, vomiting and anorexia. Radiographs revealed a dorsal deviation or deformation of the caudal part of the soft palate in 10 of the cats, a soft tissue density across the cranial nasopharynx in four and no abnormality in one. The stenosis was initially dilated with a Kelly forceps in 10 of the cats and by balloon dilatation in five. A segment of a 24 Fr silicone thoracic catheter was used for the stent in five cats; in the other 10 cats a segment of a 28 Fr catheter was used. The stent was removed after 3 weeks in 12 cats and after 4 weeks in the other three. Endoscopy revealed an adequate nasopharyngeal diameter in all of the cats. At both 3 and 10 months after surgery the response was considered to be satisfactory, with complete resolution of clinical signs in 14 cats and improvement in the remaining cat. The treatment of ANS by stenosis dilatation followed by temporary stenting with a silicone stent is a rapid, safe, economical and effective procedure. © ISFM and AAFP 2014.
Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter
2014-01-01
Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. Conclusion Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment. PMID:24958153
Automated peroperative assessment of stents apposition from OCT pullbacks.
Dubuisson, Florian; Péry, Emilie; Ouchchane, Lemlih; Combaret, Nicolas; Kauffmann, Claude; Souteyrand, Géraud; Motreff, Pascal; Sarry, Laurent
2015-04-01
This study's aim was to control the stents apposition by automatically analyzing endovascular optical coherence tomography (OCT) sequences. Lumen is detected using threshold, morphological and gradient operators to run a Dijkstra algorithm. Wrong detection tagged by the user and caused by bifurcation, struts'presence, thrombotic lesions or dissections can be corrected using a morphing algorithm. Struts are also segmented by computing symmetrical and morphological operators. Euclidian distance between detected struts and wall artery initializes a stent's complete distance map and missing data are interpolated with thin-plate spline functions. Rejection of detected outliers, regularization of parameters by generalized cross-validation and using the one-side cyclic property of the map also optimize accuracy. Several indices computed from the map provide quantitative values of malapposition. Algorithm was run on four in-vivo OCT sequences including different incomplete stent apposition's cases. Comparison with manual expert measurements validates the segmentation׳s accuracy and shows an almost perfect concordance of automated results. Copyright © 2014 Elsevier Ltd. All rights reserved.
Demonstration of bacterial biofilms in culture-negative silicone stent and jones tube.
Parsa, Kami; Schaudinn, Christoph; Gorur, Amita; Sedghizadeh, Parish P; Johnson, Thomas; Tse, David T; Costerton, John W
2010-01-01
To demonstrate the presence of bacterial biofilms on a dacryocystorhinostomy silicone stent and a Jones tube. One dacryocystorhinostomy silicone stent and one Jones tube were removed from 2 patients who presented with an infection of their respective nasolacrimal system. Cultures were obtained, and the implants were processed for scanning electron microscopy and confocal laser scanning microscopy, advanced microscopic methods that are applicable for detection of uncultivable biofilm organisms. Routine bacterial cultures revealed no growth, but bacterial biofilms on outer and inner surfaces of both implants were confirmed by advanced microscopic techniques. To the authors' knowledge, this is the first article that documents the presence of biofilms on a Crawford stent or a Jones tube on patients who presented with infections involving the nasolacrimal system. Although initial cultures revealed absence of any bacterial growth, confocal laser scanning microscopy and scanning electron microscopy documented bacterial colonization. Clinicians should consider the role of biofilms and the limitation of our standard culturing techniques while treating patients with device- or implant-related infections.
Mohammed, Noor; Pinder, Matthew; Harris, Keith; Everett, Simon M
2016-07-01
Conventional endoscopic duct clearance may not be possible in up to 10%-15% of common bile duct stones (CBDS). Sphincterotomy and biliary drainage by endoprosthesis have for many years been the mainstay of management in irretrievable stones. Recent years have seen the advent of sphincteroplasty or cholangioscopically-guided electrohydraulic lithotripsy (EHL) permitting duct clearance in majority of cases. However, when bile duct clearance is not possible, options include long-term stenting followed by elective stent exchange (ESE) 6-12 monthly or permanent stent insertion (PSI) in selected cases, but it is not clear which management strategy among ESE and PSI is preferable. A retrospective review of all patients in Leeds Teaching Hospitals NHS Trust who underwent plastic stent insertion for biliary access for difficult CBDS from January 2006 to December 2011 was undertaken. Adult patients with irretrievable CBDS who had plastic stent insertions throughout the follow-up period were included. Patients who underwent PSI and ESE annually were retrospectively reviewed to determine the long-term outcomes. A detailed systematic review was also performed, examining the outcomes of CBDS managed with stents. During the study period, 674 patients underwent 1769 biliary-stent-related procedures; of which, 246 patients met our inclusion criteria. 201 patients had subsequent duct clearance. 45 patients were, therefore, included in the final analysis, 28 of whom underwent annual ESEs and 17 PSIs. Patients in the PSI group had higher American Society of Anesthesiologists (ASA) scores compared with the ESE group. In the PSI group, 9/17 patients presented acutely with blocked stents, 5 of whom presented within 12 months. 2/9 patients were severely ill and died within a fortnight following the repeat endoscopic retrograde cholangiopancreatography (ERCP). In the ESE group, 4/28 patients had duct clearance in subsequent ERCPs, 1/28 patient presented with a blocked stent, and no biliary-related deaths were observed. The mean numbers of ERCPs performed were 0.52 and 1.95 in the PSI and ESE groups, respectively. Over 50% of patients treated with long-term stenting re-presented acutely with stent blockage, though many of these were before 12 months, meaning planned stent exchange would not have affected the outcome. Duct clearance using all possible modalities is the preferred option, but where not possible, management with biliary stenting either with elective exchange or permanent stenting remains a possibility for carefully selected patients, though maybe best suited to those with limited life expectancy.
Kalia, Junaid; Wolfe, Thomas; Zaidat, Osama O
2010-03-01
The pericallosal artery is rarely associated with intracranial atherosclerotic disease and, until recently, was usually not amenable to endovascular therapy with balloon angioplasty and stenting. We present an elderly patient with postural left leg-shaking episodes secondary to pericallosal artery stenosis, which was treated initially with primary intracranial balloon angioplasty, and subsequently, angioplasty and stenting as a result of recurrent stenosis. Both procedures were preformed without complications, and the patient remained free of symptoms on 6-month follow-up. This case demonstrates unique clinical and neuroendovascular aspects; the isolated postural leg-shaking transient ischemic attacks, initially mistaken for radiculopathy and local joint etiology, were found later to be cerebrovascular ischemic in origin. Moreover, the correlation between the findings of computed tomography perfusion and angiography localized the lesion into the medial frontal lobe and pericallosal artery territory. In addition, the technical aspect provides insight into the current state of neuroendovascular techniques, addressing the difficulty of access into very small and distal intracranial arteries affected by stenosis. Copyright 2010 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Fiber laser micromachining of thin NiTi tubes for shape memory vascular stents
NASA Astrophysics Data System (ADS)
Liu, Lei; Li, Dong Bo; Tong, Yi Fei; Zhu, Yu Fu
2016-07-01
Nickel titanium (NiTi) alloy has widely been used in the vascular stent manufacturing due to its excellent properties. Neodymium-doped yttrium aluminum garnet (Nd:YAG) laser is commonly used for the preparation of metal vascular stents. Recently, fiber lasers have been used for stent profiling for better cutting quality. To investigate the cutting-kerf characters of NiTi vascular stents fabricated by fiber laser cutting, laser cutting experiments with thin NiTi tubes were conducted in this study, while NiTi sheets were used in other fiber laser cutting studies. Different with striation topography, new topographies such as layer topography and topography mixed with layers and striations were observed, and the underlying reason for new topographies was also discussed. Comparative research on different topographies was conducted through analyzing the surface roughness, kerf width, heat-affected zone (HAZ) and dross formation. Laser cutting process parameters have a comprehensive influence on the cutting quality; in this study, the process parameters' influences on the cutting quality were studied from the view of power density along the cutting direction. The present research provides a guideline for improving the cutting quality of NiTi vascular stents.
Experimental models of tracheobronchial stenoses: a useful tool for evaluating airway stents.
Marquette, C H; Mensier, E; Copin, M C; Desmidt, A; Freitag, L; Witt, C; Petyt, L; Ramon, P
1995-09-01
Stent implantation is a conservative alternative to open operation for treating benign tracheobronchial strictures. Most of the presently available stents were primarily designed for endovascular use. Their respiratory use entails a risk of iatrogenic complications. From a scientific and from an ethical point of view these risks justify preclinical evaluation of new respiratory stents in experimental models of central airway stenoses. Therefore, an attempt was made to develop such models in piglets and adult minipigs. Tracheal stenoses were obtained by creating first a segmental tracheomalacia through extramucosal resection of cartilaginous arches. The fibrous component of the stenoses was then obtained through bronchoscopic application of a caustic agent causing progressive deep mucosal and submucosal injury. Stenoses of the main bronchi were created by topical application of the caustic agent only. These models demonstrated the typical features of benign fibromalacic tracheobronchial stenoses with constant recurrence after mechanical dilation. Preliminary experiments showed that short-term problems of tolerance of stent prototypes are easily demonstrable in these models. These experimental models, which simulate quite realistically human diseases, offer the opportunity to perfect new tracheobronchial stents specifically designed for respiratory use and to evaluate their long-term tolerance before their use in humans.
Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz
2009-01-01
The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree, Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035'' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunk and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.
Sensor to detect endothelialization on an active coronary stent
2010-01-01
Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks. PMID:21050471
How do we manage post-OLT redundant bile duct?
Torres, Victor; Martinez, Nicholas; Lee, Gabriel; Almeda, Jose; Gross, Glenn; Patel, Sandeep; Rosenkranz, Laura
2013-04-28
To address endoscopic outcomes of post-Orthotopic liver transplantation (OLT) patients diagnosed with a "redundant bile duct" (RBD). Medical records of patients who underwent OLT at the Liver Transplant Center, University Texas Health Science Center at San Antonio Texas were retrospectively analyzed. Patients with suspected biliary tract complications (BTC) underwent endoscopic retrograde cholangiopancreatography (ERCP). All ERCP were performed by experienced biliary endoscopist. RBD was defined as a looped, sigmoid-shaped bile duct on cholangiogram with associated cholestatic liver biomarkers. Patients with biliary T-tube placement, biliary anastomotic strictures, bile leaks, bile-duct stones-sludge and suspected sphincter of oddi dysfunction were excluded. Therapy included single or multiple biliary stents with or without sphincterotomy. The incidence of RBD, the number of ERCP corrective sessions, and the type of endoscopic interventions were recorded. Successful response to endoscopic therapy was defined as resolution of RBD with normalization of associated cholestasis. Laboratory data and pertinent radiographic imaging noted included the pre-ERCP period and a follow up period of 6-12 mo after the last ERCP intervention. One thousand two hundred and eighty-two patient records who received OLT from 1992 through 2011 were reviewed. Two hundred and twenty-four patients underwent ERCP for suspected BTC. RBD was reported in each of the initial cholangiograms. Twenty-one out of 1282 (1.6%) were identified as having RBD. There were 12 men and 9 women, average age of 59.6 years. Primary indication for ERCP was cholestatic pattern of liver associated biomarkers. Nineteen out of 21 patients underwent endoscopic therapy and 2/21 required immediate surgical intervention. In the endoscopically managed group: 65 ERCP procedures were performed with an average of 3.4 per patient and 1.1 stent per session. Fifteen out of 19 (78.9%) patients were successfully managed with biliary stenting. All stents were plastic. Selection of stent size and length were based upon endoscopist preference. Stent size ranged from 7 to 11.5 Fr (average stent size 10 Fr); Stent length ranged from 6 to 15 cm (average length 9 cm). Concurrent biliary sphincterotomy was performed in 10/19 patients. Single ERCP session was sufficient in 6/15 (40.0%) patients, whereas 4/15 (26.7%) patients needed two ERCP sessions and 5/15 (33.3%) patients required more than two (average of 5.4 ERCP procedures). Single biliary stent was sufficient in 5 patients; the remaining patients required an average of 4.9 stents. Four out of 19 (21.1%) patients failed endotherapy (lack of resolution of RBD and recurrent cholestasis in the absence of biliary stent) and required either choledocojejunostomy (2/4) or percutaneous biliary drainage (2/4). Endoscopic complications included: 2/65 (3%) post-ERCP pancreatitis and 2/10 (20%) non-complicated post-sphincterotomy bleeding. No endoscopic related mortality was found. The medical records of the 15 successful endoscopically managed patients were reviewed for a period of one year after removal of all biliary stents. Eleven patients had continued resolution of cholestatic biomarkers (73%). One patient had recurrent hepatitis C, 2 patients suffered septic shock which was not associated with ERCP and 1 patient was transferred care to an outside provider and records were not available for our review. Although surgical biliary reconstruction techniques have improved, RBD represents a post-OLT complication. This entity is rare however, endoscopic management of RBD represents a reasonable initial approach.
The full metallic double-pigtail ureteral stent: Review of the clinical outcome and current status
Kallidonis, Panagiotis S.; Georgiopoulos, Ioannis S.; Kyriazis, Iason D.; Kontogiannis, Stavros; Al-Aown, Abdulrahman M.; Liatsikos, Evangelos N.
2015-01-01
The full metallic double-J ureteral stent (MS) was introduced as a method for providing long-term drainage in malignant ureteral obstruction. Experimental evaluation of the MS revealed that its mechanical features allow efficient drainage in difficult cases, which could not be managed by the insertion of a standard polymeric double-J stent. Clinical experience with the MS showed controversial results. Careful patient selection results in efficient long-term management of malignant ureteral obstruction. The use of the MS should also be considered in selected benign cases. Major complications are uncommon and the minor complications should not hinder its use. Experience in pediatric patients is limited and warrants additional study. The cost-effectiveness of the MS seems to be appropriate for long-term treatment. Further investigation with comparative clinical trials would document the outcome more extensively and establish the indications as well as the selection criteria for the MS. PMID:25624569
Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin
2017-06-26
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Liatsikos, Evangelos N; Kagadis, George C; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Papathanassiou, Zafiria; Constantinides, Constantinos; Perimenis, Petros; Nikiforidis, George C; Stolzenburg, Jens-Uwe; Siablis, Dimitrios
2007-07-01
We report our long-term experience with the management of benign ureteroileal anastomotic strictures using self-expandable metal stents. A total of 16 male and 2 female patients with a mean+/-SD age of 72+/-7 years (range 66 to 78) with benign fibrotic strictures at the site of ureteroileal anastomosis underwent implantation of self-expandable metal stents with a nominal diameter of 6 to 8 mm. A total of 24 ureteroileal conduits were treated. The external nephrostomy tubes were removed after fluoroscopic validation of ureteral patency. Patients were followed with blood biochemistry, ultrasonography, urography and/or virtual endoscopy. Retrograde external-internal catheter insertion through the cutaneous stoma was performed in cases of recalcitrant stricture. The technical success rate of ureteroileal stricture crossing and stenting was 100% (24 of 24 cases). Mean followup was 21 months (range 7 to 50). The clinical success rate during the immediate post-stenting period was 70.8% (17 of 24 cases). The 1 and 4-year primary patency rates were 37.8% and 22.7%, respectively. Secondary interventions included repeat balloon dilation in 15 ureters, of which 8 also underwent subsequent coaxial stent placement. The 1 and 4-year secondary patency rates were 64.8% and 56.7%, respectively. Except in 2 patients who died external-internal Double-J catheters continued to be inserted retrograde in 6 ureteroileal conduits. They are periodically exchanged to prevent mucous inspissation and stent encrustation. Metal stents served as the definitive treatment for stricture in more than half of the cases, whereas in the remainder the stents allowed the uncomplicated and regular exchange of Double-J catheters in retrograde fashion. This combined, less invasive treatment for ureteroileal anastomotic strictures may help patients avoid surgical revision and preserve quality of life.
Urethroplasty after Urethral Urolume Stent: an International Multicenter Experience.
Angulo, Javier C; Kulkarni, Sanjay; Pankaj, Joshi; Nikolavsky, Dmitriy; Suarez, Pedro; Belinky, Javier; Virasoro, Ramón; DeLong, Jessica; Martins, Francisco E; Lumen, Nicolaas; Giudice, Carlos; Suárez, Oscar A; Menéndez, Nicolás; Capiel, Leandro; López-Alvarado, Damian; Ramirez, Erick A; Venkatesan, Krishnan; Husainat, Maha M; Esquinas, Cristina; Arance, Ignacio; Gómez, Reynaldo; Santucci, Richard
2018-05-08
To evaluate the outcomes and factors affecting success of urethroplasty in patients with stricture recurrence after Urolume® urethral stent. Retrospective international multicenter study on patients treated with urethral reconstruction after Urolume® stent. Stricture and stent length, time between urethral stent insertion and urethroplasty, age, mode of stent retrieval, type of urethroplasty, complications and baseline and post-urethroplasty voiding parameters were analyzed. Successful outcome was defined as standard voiding, without need of any postoperative adjunctive procedure. Sixty-three patients were included. Stent was removed at urethroplasty in 61 patients. Reconstruction technique was excision and primary anastomosis in 14(22.2%), dorsal onlay buccal mucosa graft (BMG) 9(14.3%), ventral onlay BMG 6(9.5%), dorso-lateral onlay BMG 9(14.3%), ventral onlay plus dorsal inlay BMG 3(4.8%), augmented anastomosis 5(7.9%), pedicled flap urethroplasty 6(9.5%), 2-stage procedure 4(6.4%) and perineal urethrostomy 7(11.1%). Success rate was 81% at a mean 59.7+63.4months. Dilatation and/or internal urethrotomy was performed in 10(15.9%), redo-urethroplasty in 5(7.9%). Total IPSS, QoL, Qmax and PVR significantly improved (p<.0001). Complications occurred in 8(12.7%), all Clavien-Dindo <2. Disease-free survival rate after reconstruction was 88.1%,79.5% and 76.7% at 1,3 and 5-years respectively. Explant of individual strands followed by onlay BMG is the most common approach and was significantly advantageous over the other techniques (p=.018). Urethroplasty in patients with Urolume® urethral stents is a viable option of reconstruction with a high success rate and very acceptable complication rate. Numerous techniques are viable, however, urethral preservation, tine-by-tine stent extraction and use of BMG augmentation produced significantly better outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soh, Keng Chuan; Tay, Kiang Hiong, E-mail: tay.kiang.hiong@sgh.com.sg; Tan, Bien Soo
2008-05-15
Our aim was to review our experience with percutaneous antegrade ureteric stent (PAUS) placement and to determine if the routinely conducted check nephrostogram on the day following ureteric stent placement was necessary. Retrospective review of patients who had undergone PAUS placement between January 2004 and December 2005 was performed. There were 83 subjects (36 males, 47 females), with a mean age of 59.9 years (range, 22-94 years). Average follow-up duration was 7.1 months (range, 1-24 months). The most common indications for PAUS placement were ureteric obstruction due to metastatic disease (n = 56) and urinary calculi (n = 34). Technicalmore » success was 93.2% (96/103 attempts), with no major immediate procedure-related complications or mortalities. The Bard 7Fr Urosoft DJ Stent was used in more than 95% of the cases. Eighty-one of 89 (91.0%) check nephrostograms demonstrated a patent ureteric stent with resultant safety catheter removal. Three check nephrostograms revealed distal stent migration requiring repositioning by a goose-snare, while five others showed stent occlusion necessitating permanent external drainage by nephrostomy drainage catheter reinsertion. Following PAUS placement, the serum creatinine level improved or stabilized in 82% of patients. The serum creatinine outcome difference between the groups with benign and malignant indications for PAUS placement was not statistically significant (p = 0.145) but resolution of hydronephrosis was significantly better (p = 0.008) in patients with benign indications. Percutaneous antegrade ureteric stent placement is a safe and effective means of relief for ureteric obstruction. The check nephrostogram following ureteric stent placement was unnecessary in the majority of patients.« less
[Experimental study of an intratracheal stent made of shape memory alloy].
Yoshimura, M; Tsugawa, C; Tsubota, N
1994-11-01
To develop a new prosthesis for treating tracheal stenosis and tracheobronchomalacia, we examined the usefulness of an intratracheal stent made of shape memory alloy (SMA), a titanium-nickel alloy composed of 50% of each metal. At its recovery temperature (37 degrees C), the SMA stent was designed to recall the memorized shape of a coil with a diameter of 5 or 6 mm and a length of 10 mm. For the present experiment, it was transformed to a smaller coil 3 mm in diameter at a low temperature (-50 degrees C) and then loaded into the prosthesis introducer tube. An experimental model of potentially fatal tracheomalacia was made surgically by cutting and fracturing the tracheal cartilages of rabbits and tracheal collapse was confirmed by rigid bronchoscope. The introducer tube with the SMA stent was inserted and then the prosthesis was advanced into the collapsed segment of the trachea using the stent pusher. The SMA stent warmed bo body temperature and recovered its memorized shape after 1-2 min. In 3 out of 8 rabbits, follow-up bronchoscopy performed at 6, 8, and 10 months after implantation revealed satisfactory patency of the SMA stent and the trachea. After follow-up, 3 animals were sacrificed for histological observation, which showed little proliferation of granulation tissue and no dislocation of the SMA stent from the malacic portion. The remaining 5 rabbits have been followed for 18-24 months and are doing well. We conclude that the SMA stent maintains good tracheal patency, causes little reaction in the tracheal wall, and is easy to handle. Thus, it shows the potential for clinical application.
Yang, Fuchun; Ren, Zhigang; Chai, Qinming; Cui, Guangying; Jiang, Li; Chen, Hanjian; Feng, Zhiying; Chen, Xinhua; Ji, Jian; Zhou, Lin; Wang, Weilin; Zheng, Shusen
2016-01-01
Symptomatic biliary stricture causes life-threatening complications, such as jaundice, recurrent cholangitis and secondary biliary cirrhosis. Fully covered self-expanding metal stents (FCSEMSs) are gaining acceptance for treatments of benign biliary stricture and palliative management of malignant biliary obstructions. However, the high rate of FCSEMS obstruction limits their clinic use. In this study, we developed a novel biliary stent coated with silver nanoparticles (AgNPs) and investigated its efficacy both in vitro and in vivo. We first identified properties of the AgNP complex using ultraviolet detection. The AgNP complex was stable without AgNP agglomeration, and Ag abundance was correspondingly increased with an increased bilayer number. The AgNP biliary stent demonstrated good performance in the spin-assembly method based on topographic observation. The AgNP biliary stent also exhibited a long-term anti-coagulation effect and a slow process of Ag+ release. In vitro anti-bacteria experiments indicated that the AgNP biliary stent exhibited high-efficiency anti-bacterial activity for both short- and long-term periods. Importantly, application of the AgNP biliary stent significantly prolonged the unobstructed period of the biliary system and improved survival in preclinical studies as a result of its anti-microbial activity and decreased granular tissue formation on the surface of the anastomotic biliary, providing a novel and effective treatment strategy for symptomatic biliary strictures. PMID:26883081
Baek, Minki; Au, Jason; Huang, Gene O; Koh, Chester J
2017-04-01
We describe our experience with robot-assisted laparoscopic (RAL) pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis with an emphasis on the various double J (DJ) ureteral stent placement techniques. We used our RAL pyeloureterostomy technique in two female infants with duplex systems and upper pole hydronephrosis. For case 1, we introduced the DJ stent and placed it in the recipient lower pole ureter during the robotic operation in an antegrade fashion. For case 2, we inserted the DJ stent during retrograde pyelography prior to the robotic procedure in a retrograde fashion, and the proximal portion of the stent was placed across the anastomosis into the upper pole renal pelvis. Postoperatively, each of the patients were discharged on postoperative day 1 without complications. The postoperative renal ultrasound at 3 months demonstrated marked improvement of the right upper pole hydronephrosis in both patients. RAL pyeloureterostomy represents a minimally invasive option for upper tract reconstruction of duplex systems with upper pole hydronephrosis in infants. The DJ stent can be placed at the beginning or during the procedure. The stent can be placed in the lower pole ureter or across the anastomosis into the upper pole renal pelvis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lenton, James, E-mail: jlenton@doctors.org.u; Davies, John; Homer-Vanniasinkam, S.
An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms withmore » stent-grafts has not been previously reported in the adolescent population.« less
OCT assisted identification of the grade of encrustation of urologic catheters
NASA Astrophysics Data System (ADS)
Sroka, Ronald; Püls, Michaela; Stepp, Herbert; Zilinberg, Katja; Bader, Markus; Weidlich, Patrick
2013-06-01
Introduction: Ureteric stenting is a commonly used endourologic procedure for temporary and long-term drainage of an obstructed upper urinary tract. The indication for ureteric stenting is obstruction due to intrinsic (intraureteral stones, strictures, or tumors) or extrinsic (for example compressing pelvic or retroperitoneal mass) causes. Despite the fact that stents do certainly have proven benefits in all fields of urology, there are potential morbidities. The most common problem of indwelling ureteral stents is infection. As foreign body in the urinary system, stents act as a nidus for bacteria colonization, crystallization and encrustation. Bacteria induced biofilm formation predisposes for the crystallization of lithogenic salts, such as calcium-phosphate, calcium-oxalate, magnesium-phosphate on the surface initiating stent encrustation. It was the objective of this study to evaluate whether optical coherence tomography (OCT) using both the surface and the endoluminal technique is feasible to investigate the locations and degree of encrustation process in clinically used ureteral stents. Patients and methods: After removal from patients, fourteen polyurethane JJ stents were investigated. A fresh JJ served as a control. The external surfaces were examined using an endoscopic surface OCT whereas the intraluminal surfaces were investigated by an endoluminal radial OCT device. The focus was on detection of encrustation or crystalline sedimentation. Results: In 12 female and 2 male patients, the median indwelling time of the ureteral catheter was 100 days (range 19- 217). Using the endoluminal OCT, the size and grade of intraluminal encrustation could be expressed as a percentage relating to the open lumen of the reference stent. The maximum encrustation observed resulted in a remaining unrestricted lumen of 15-35% compared to the reference. The luminal reduction caused by encrustation was significantly higher at the proximal end of the ureteral stent as compared to its distal part. The extraluminal OCT-investigations facilitated the characterization of extraluminal encrustation. Conclusion: OCT techniques were feasible and facilitated the detection of encrustation of double pigtail catheters on both the extra and intra luminal surface. Quantitative expression of the degree of intraluminal encrustation could be achieved, with the most dense and thickened occurrence of intraluminal incrustation in the upper curl of the JJ stent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
D’Oria, Mario, E-mail: mario.doria88@outlook.com; Sgorlon, Giada; Calvagna, Cristiano
We report our experience with the urgent treatment of two high-risk patients with infected femoral artery pseudoaneurysms (IFAPs) with the placement of a self-expandable covered stent (SECS). In both cases, there was no perioperative mortality and the aneurysm exclusion was successful without early or late stent thrombosis/stent fracture nor acute or chronic limb ischemia or limb loss. There was no recurrence of local or systemic infection during the follow-up period. Endovascular therapy represents a feasible treatment option for IFAPs in those patients for whom the risk of open surgical repair would be prohibitive, especially under urgent circumstances.
Stolker, Joshua M; Cohen, David J; Kennedy, Kevin F; Pencina, Michael J; Arnold, Suzanne V; Kleiman, Neal S; Spertus, John A
Drug-eluting stents (DES) reduce restenosis but require prolonged antiplatelet therapy, when compared with bare metal stents. Ideally, the patient should be involved in this risk:benefit assessment prior to selecting DES, to maximize the benefits and cost-effectiveness of care, and to improve medication adherence. However, accurate estimation of restenosis risk may require angiographic factors identified at cardiac catheterization. In a large PCI registry, we used logistic regression to identify clinical and angiographic predictors of clinically-driven target lesion revascularization (TLR) over the first year after stent placement. Discrimination c-statistic and integrated discrimination improvement (IDI) were used to calculate the incremental utility of angiographic variables when added to clinical predictors. Of 8501 PCI patients, TLR occurred in 4.5%. After adjusting for DES use, clinical TLR predictors were younger age, female sex, diabetes, prior PCI, and prior bypass surgery (model c-statistic 0.630). Angiographic predictors were vein graft PCI, in-stent restenosis lesion, longer stent length, and smaller stent diameter (c-statistic 0.650). After adding angiographic factors to the clinical model, c-statistic improved to 0.680 and the average separation in TLR risk among patients with and without TLR improved by 1% (IDI=0.010, 95% CI 0.009-0.014), primarily driven by those experiencing TLR (from 5.9% to 6.9% absolute risk). Among unselected PCI patients, the incidence of clinically-indicated TLR is <5% at 1-year, and standard clinical variables only moderately discriminate who will and will not experience TLR. Angiographic variables significantly improve TLR risk assessment, suggesting that stent selection may be best performed after coronary anatomy has been delineated. Although several recent studies have challenged traditional expectations regarding the duration of dual antiplatelet therapy, current guidelines recommend at least 6 to 12months of treatment after implantation of a drug eluting stent, with a shorter course for bare metal stents. Stent selection ideally should involve input from the patient receiving these stents, but multiple studies have suggested that angiographic factors - obtained after the patient has received sedation during the diagnostic catheterization - are important predictors of repeat revascularization. In this analysis from a large registry of patients receiving coronary stents, angiographic characteristics were found to significantly improve risk assessment for target lesion revascularization, when added to clinical variables alone. Copyright © 2016 Elsevier Inc. All rights reserved.
Magnetoelastic galfenol as a stent material for wirelessly controlled degradation rates.
DeRouin, Andrew; Guillory, Roger; He, Weilue; Frost, Megan; Goldman, Jeremy; Ong, Keat Ghee
2018-03-23
The gold standard of care for coronary artery disease, a leading cause of death for in the world, is balloon angioplasty in conjunction with stent deployment. However, implantation injuries and long-term presence of foreign material often promotes significant luminal tissue growth, leading to a narrowing of the artery and severely restricted blood flow. A promising method to mitigate this process is the use of biodegradable metallic stents, but thus far they have either degraded too slowly (iron) or disappeared prematurely (magnesium). The present work investigates the use of a unique type of magnetic material, galfenol (iron-gallium), for postoperative wireless control of stent degradation rates. Due to its magnetoelastic property, galfenol experiences longitudinal micron-level elongations when exposed to applied magnetic fields, allowing generation of a microstirring effect that affect its degradation behavior. In vitro indirect cytotoxicity tests on primary rat aortic smooth muscle cells indicated that galfenol byproducts must be concentrated approximately seven times from collected 60 day degradation medium to cause ∼15% of death from all cells. Surface and cross-sectional characterization of the material indicate that galfenol (Fe 80 Ga 20 ) degradation rates (∼0.55% per month) are insufficient for stenting applications. While this material may not be ideal for comprising the entire stent, there is potential for use in combination with other materials. Furthermore, the ability to control degradation rates postimplantation opens new possibilities for biodegradable stents; additional magnetoelastic materials should be investigated for use in stenting applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc.
Metallic Stents for Tracheobronchial Pathology Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serrano, Carolina, E-mail: carolina.serrano@unizar.es; Laborda, Alicia, E-mail: alaborda@unizar.es; Lozano, Juan M., E-mail: juamauloz@gmail.com
2013-12-15
Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniquesmore » at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.« less
Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan
2014-12-01
To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length < 1 cm: 21 Cristallo Ideale (Invatec, Roncadelle, Italy); straight vessel, lesion length > 1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Canyigit, Murat; Arat, Anil; Cil, Barbaros E.
2007-04-15
Purpose. We retrospectively evaluated our experience with stenting of the vertebral artery in an effort to determine the risk of distal embolization associated with the procedure. Methods. Between June 2000 and May 2005, 35 patients with 38 stenting procedures for atherosclerotic disease of the vertebral origin in our institution were identified. The average age of the patients was 60.3 years (range 32-76 years). Sixteen of these patients (with 18 stents) had MR imaging of the brain with diffusion-weighted imaging and an apparent diffusion coefficient map within 2 days before and after procedure. Results. On seven of the 16 postprocedural diffusion-weightedmore » MR images, a total of 57 new hyperintensities were visible. All these lesions were focal in nature. One patient demonstrated a new diffusion-weighted imaging abnormality in the anterior circulation without MR evidence of posterior circulation ischemia. Six of 16 patients had a total of 25 new lesions in the vertebrobasilar circulation in postprocedural diffusion-weighted MR images. One patient in this group was excluded from the final analysis because the procedure was complicated by basilar rupture during tandem stent deployment in the basilar artery. Hence, new diffusion-weighted imaging abnormalities were noted in the vertebrobasilar territory in 5 of 15 patients after 17 stenting procedures, giving a 29% rate of diffusion-weighted imaging abnormalities per procedure. No patient with bilateral stenting had new diffusion-weighted imaging abnormalities. Conclusion. Stenting of stenoses of the vertebral artery origin may be associated with a significant risk of asymptomatic distal embolization. Angiography, placement of the guiding catheter, inflation of the stent balloon, and crossing the lesion with guidewires or balloon catheters may potentially cause distal embolization. Further studies to evaluate measures to increase the safety of vertebral artery stenting, such as the use of distal protection devices or short-term postprocedural anticoagulation, should be considered for patients with clear indications for this procedure.« less
Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan
2014-01-01
To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length < 1 cm: 21 Cristallo Ideale (Invatec, Roncadelle, Italy); straight vessel, lesion length > 1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58–87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1–59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up. PMID:25484558
Chemical etching of nitinol stents.
Katona, Bálint; Bognár, Eszter; Berta, Balázs; Nagy, Péter; Hirschberg, Kristóf
2013-01-01
At present the main cause of death originates from cardiovascular diseases. Primarily the most frequent cause is vessel closing thus resulting in tissue damage. The stent can help to avoid this. It expands the narrowed vessel section and allows free blood flow. The good surface quality of stents is important. It also must have adequate mechanical characteristics or else it can be damaged which can easily lead to the fracture of the implant. Thus, we have to consider the importance of the surface treatment of these implants. In our experiments the appropriate design was cut from a 1.041 mm inner diameter and 0.100 mm wall thickness nitinol tube by using Nd:YAG laser device. Then, the stent was subjected to chemical etching. By doing so, the burr created during the laser cutting process can be removed and the surface quality refined. In our research, we changed the time of chemical etching and monitored the effects of this parameter. The differently etched stents were subjected to microscopic analysis, mass measurement and in vivo environment tests. The etching times that gave suitable surface and mechanical features were identified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi
Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months.more » Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.« less
Iijima, Raisuke; Kougame, Norihiro; Hara, Hidehiko; Moroi, Masao; Nakamura, Masato
2018-06-12
The aim of this study was to investigate whether drug-coated balloon (DCB) treatment is effective for de novo coronary lesions that are unsuitable for drug-eluting stent (DES) implantation.Methods and Results:This retrospective study included 118 de novo lesions that were not suitable for DES implantation. Of the lesions, 40% was treated because of very small vessel disease. Patients with planned non-cardiac surgery and at high bleeding risk were 3% and 19%, respectively, and lesions that easily develop stent fracture comprised 26%. Clinically driven target lesion revascularization (TLR) was the primary endpoint. The rate of suboptimal lesion preparation before DCB treatment was set as the secondary endpoint. Optimal lesion preparation was defined as acquisition of Thrombolysis in Myocardial Infarction flow grade 3, minor coronary dissection, and residual stenosis ≤30%. The rate of suboptimal lesion preparation was 2.5% and 3 patients needed bail-out stenting. Accordingly, 115 patients were treated with a DCB. Clinically driven TLR had occurred in 8 patients (7.0%) at the 8-month follow-up. The presence of chronic total occlusion was identified as an independent predictor for TLR (odds 11.57; 95% confidence interval, 1.38-135.54; P=0.02). For lesions that are unsuitable for stent implantation, stent-less intervention using a DCB should be considered initially. The present study also highlighted that lesion preparation is key to a successful DCB strategy.
Origins of medical innovation: the case of coronary artery stents.
Xu, Shuai; Avorn, Jerry; Kesselheim, Aaron S
2012-11-01
Innovative medical devices make major contributions to patient welfare, and coronary stents have been among the most important device developments of recent decades. However, the origins of such breakthrough medical technologies remain poorly understood. Using a comprehensive database of patents, we identified all individuals and institutions that developed intellectual property related to stent technology early in its development process. The patents were categorized and described using a predetermined qualitative coding strategy. We found 245 granted patents related to bare metal coronary artery stents from 1984 (when the first patent issued in this field) to 1994 (after the first stents were approved). Each year showed an increase in the number of patent filings: from 1 in 1984 to 97 in 1994. The largest fraction of patents was issued to private entities (44.9% of the total). Public companies, individual inventors, and nonprofit institutions represented 31.4%, 18.0%, and 5.7%, respectively. The top 10 most-cited patents in the field were dominated by 2 private entities, Expandable Grafts Partnership and Cook Inc, organizations created by or dependent on the work of independent academic physician-inventors. Coronary artery stent technology first arose from individual physician-inventors within academic medical centers and their associated private companies. After these initial innovations were in place, the field became dominated by large public companies. This history suggests that policies aimed at encouraging transformative medical device development would have their greatest effect if focused on individual inventors and scientists performing the early stages of technology development.
Update on perioperative care of the cardiac patient for noncardiac surgery.
Ghadimi, Kamrouz; Thompson, Annemarie
2015-06-01
The current review will address key topics and recommendations of the recent 2014 update of the American College of Cardiology and American Heart Association clinical practice guideline for the perioperative cardiovascular evaluation and management of patients undergoing noncardiac surgery. The completely rewritten guideline provides a stepwise approach for the identification and management of patients at highest risk for major adverse cardiac events and discusses new or updated recommendations. For example, β-blockers should be continued perioperatively but treatment should not be initiated within 24 h of noncardiac surgery. Angiotensin-converting enzyme inhibitors should be continued, but if held, may be restarted as soon as feasible. Routine aspirin therapy is not recommended without previous coronary stent implantation or risk assessment for myocardial ischemia. Elective noncardiac surgery should not be performed within 30 days of bare metal stent or 12 months of drug-eluting stent implantation because of in-stent thrombosis as well as bleeding risk from dual antiplatelet therapy during surgery. Noncardiac surgery may be considered, however, in patients on antiplatelet agents 180 days after drug-eluting stent placement if risk of surgical delay exceeds risk of stent thrombosis from cessation of antiplatelet therapy. In conclusion, this review will discuss the important topics from the 2014 American College of Cardiology/American Heart Association guideline in order to provide the perioperative physician with the most recent evidence necessary to minimize major adverse cardiac events in patients undergoing noncardiac surgery.
Long-term complications of JJ stent and its management: A 5 years review.
Ray, Rajendra Prasad; Mahapatra, Rajkumar Singha; Mondal, Partha Pratim; Pal, Dilip Kumar
2015-01-01
To assess the long term complications of JJ stent, the management of complications and the role of endoscopic approach to manage these complications. Nineteen patients with indwelling JJ stent for a duration of more than 6 months were included in this study. Patients were assessed with X-ray KUB, USG KUB, blood urea, creatinine and DTPA renogram. Data were analyzed by Microsoft excel 2007. Out of 19 patients 12 (63.16%) were male and 7 (36.84%) were female. The mean age was 39.78 ± 13.69 years., Mean duration for which the stent was in situ was 29.56 months. The most common complication was broken stent, in 11 cases (57.89%). Other complications were migration in 5 (26.32%), encrustation in 2 (10.52%) and 1 case of (5.26%) stone formation. Eighteen cases were managed by endoscopic approaches. A total of 22 procedures were performed to treat the complications. Eleven cases were managed by a single procedure and 8 patients required multiple procedures. All were managed successfully with no death reported. Post-operative complications were seen in eight cases (42.11%). JJ stent related long-term complications are not uncommon and are usually seen after 6 months of indwelling time. Endourological procedure should be the initial approach with a high success rate. Coordinated use multimodality and technology helps in management of difficult cases. Open surgery is rarely required. Prevention of the complication by judicious use and early removal is the cornerstone.
Liu, Yanhui; Zhang, Peihua
2016-09-01
This paper presents a study of the compression behaviors of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body by finite element method. To investigate the relationship between the compression force and structure parameter (monofilament diameter and braid-pin number), nine numerical models based on actual biliary stent were established, the simulation and experimental results are in good agreement with each other when calculating the compression force derived from both experiment and simulation results, indicating that the simulation results can be provided a useful reference to the investigation of biliary stents. The stress distribution on FCBPBSs was studied to optimize the structure of FCBPBSs. In addition, the plastic dissipation analysis and plastic strain of FCBPBSs were obtained via the compression simulation, revealing the structure parameter effect on the tolerance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chatterjee, Susanta; Rath, Suryasnata; Roy, Aravind; Shrestha, Eliya
2013-10-01
To evaluate the outcome of 20G silicone rod as monocanalicular stent in canalicular lacerations. Retrospective case series involving patients between July 2006 and June 2010. Fourteen canalicular repairs in 12 consecutive patients were done in the study period. Eleven were male and mean age was 30.5 years. A single canaliculus was involved in 10 patients and associated injury to the globe was noted in 3 patients. The median lag time between injury and repair was 3 (range 1-9) days. The mean duration of stenting was 6.9 (SD 3.2) weeks. Spontaneous extrusion of monocanalicular stent occurred in 3 patients. Patency on syringing was noted in 10 (70%) canaliculi over a median follow up of 7 (range 2-17) months. 20G silicone rod may be used as an effective and economical alternative in canalicular lacration repairs.
Chatterjee, Susanta; Rath, Suryasnata; Roy, Aravind; Shrestha, Eliya
2013-01-01
To evaluate the outcome of 20G silicone rod as monocanalicular stent in canalicular lacerations. Retrospective case series involving patients between July 2006 and June 2010. Fourteen canalicular repairs in 12 consecutive patients were done in the study period. Eleven were male and mean age was 30.5 years. A single canaliculus was involved in 10 patients and associated injury to the globe was noted in 3 patients. The median lag time between injury and repair was 3 (range 1-9) days. The mean duration of stenting was 6.9 (SD 3.2) weeks. Spontaneous extrusion of monocanalicular stent occurred in 3 patients. Patency on syringing was noted in 10 (70%) canaliculi over a median follow up of 7 (range 2-17) months. 20G silicone rod may be used as an effective and economical alternative in canalicular lacration repairs. PMID:24212309
Kaneko, Takashi; Sugimori, Kazuya; Shimizu, Yuro; Miwa, Haruo; Kameta, Eri; Koh, Ryonho; Numata, Kazushi; Tanaka, Katsuaki; Maeda, Shin
2014-05-01
Recent reports have addressed the utility of plastic stent (PS) placement inside bile ducts for treating biliary obstructions. Here, we evaluated the utility and safety of PS placement inside bile ducts for treating unresectable malignant hilar biliary obstruction. We conducted a retrospective study of 27 patients with unresectable malignant hilar biliary obstruction who underwent intraductal modified PS placement. We modified the PS, by cutting off the distal end to facilitate insertion through the papilla of Vater, and attached a nylon thread to the distal end for removal. We evaluated complications, the time to recurrent biliary obstruction (TRBO), and removability. Bilateral stenting was performed in nine of the 27 patients. Mild acute pancreatitis occurred in one patient (4%). Recurrent biliary obstruction (RBO) occurred in 16 patients (59%), with a median TRBO of 190 days (95% confidence interval: 174-205 days). Reintervention was necessary in 13 of the 16 patients (81%) with RBO, and we were able to remove the initial stents in all the patients who required reintervention. A relatively long stent patency period (>6 months) and removability make placement of a modified PS inside bile ducts a viable treatment for unresectable malignant hilar biliary obstruction. © 2013 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J
2017-04-24
The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Knowles, Martyn; Pellisar, Tiago; Murphy, Erin H; Stanley, Gregory A; Hashmi, Abraham F; Arko, M Zachary; Arko, Frank R
2011-08-01
To evaluate the effects of type II endoleaks and sac pressurization on stent-graft displacement following endovascular aneurysm repair (EVAR). Experimental silicone infrarenal aneurysm (6-cm) models were "treated" with a Talent stent-graft deployed with 20-mm proximal and distal landing zones. Inflow and outflow vessels were created as part of the silicone model to control flow into the aneurysm sac. All aneurysm models were uniform, with a diameter neck of 31 mm, a neck length of 20 mm, and iliac artery diameters of 16 mm. The aortic model was secured in a water bath to a pulsatile pump under physiological conditions; the output phase ratio (%systole/%diastole) was set at 65/35 with a pump rate of 80 beats per minute. Commercially available bifurcated stent-grafts were then displaced in vitro utilizing a linear motion apparatus attached to a force gauge. The mean arterial pressure (MAP) and pulse pressure (PP) at the aortic inflow were 60.1 ± 3.1 and 38.3 ± 7.8 mmHg, respectively. Peak force to cause initial stent-graft migration with and without a type II endoleak was recorded and compared. In aneurysm sacs with no endoleak, the MAP and sac PP were 32 ± 6.4 and 6 ± 1.3 mmHg, respectively (p<0.01). In aneurysm sacs with a type II endoleak, the MAP and sac PP were 54.1 ± 9.7 and 16.1 ± 4.1 mmHg, respectively (p<0.02). Peak force to initiate migration was 16.0 ± 1.41 N (range 15-18) with no endoleak vs. 23.2 ± 2.2 N (range 20-25) in those with a type IIa endoleak and 23.5 ± 2.5 N (range 20-26) in those with a type IIb endoleak (p<0.001). Type II endoleaks are associated with a significantly increased sac pressure. Increased sac pressurization from type II endoleaks results in a significantly greater force to displace a stent-graft longitudinally. Type II endoleaks may therefore inhibit migration and offer a benefit following EVAR; however, clinical correlation of these results is required.
Robin, Elisabeth M; Pey, Pascaline B; de Fornel-Thibaud, Pauline; Moissonnier, Pierre H M; Freiche, Valérie
2018-02-01
CASE DESCRIPTION A 10-year-old spayed female Rottweiler was referred for evaluation because of a 2-month history of regurgitation and weight loss, despite no apparent change in appetite. The dog had received antiemetic and antacid treatment, without improvement. CLINICAL FINDINGS Physical examination revealed a low body condition score (2/5), but other findings were unremarkable. Diffuse, global esophageal dilatation was noted on plain thoracic radiographs, and normal motility was confirmed through videofluoroscopic evaluation of swallowing. Transhepatic ultrasonographic and CT examination revealed a circumferential, intraparietal lesion in the distal portion of the esophagus causing distal esophageal or cardial subobstruction and no metastases. Incisional biopsy of the lesion was performed, and findings of histologic examination supported a diagnosis of esophageal leiomyoma. TREATMENT AND OUTCOME In view of numerous possible complications associated with esophageal surgery, the decision was made to palliatively treat the dog by transcardial placement of a self-expanding, covered, nitinol esophageal stent under endoscopic guidance. Two weeks after stent placement, radiography revealed complete migration of the stent into the gastric lumen. Gastrotomy was performed, and the stent was replaced and fixed in place. Twenty-four months after initial stent placement, the dog had a healthy body condition and remained free of previous clinical signs. CLINICAL RELEVANCE Diffuse benign muscular neoplasia should be considered as a differential diagnosis for acquired esophageal dilatation in adult and elderly dogs. In the dog of this report, transcardial stent placement resulted in resolution of the clinical signs, with no apparent adverse effect on digestive function. The described procedure could be beneficial for nonsurgical treatment of benign esophageal tumors in dogs.
Grundeken, Maik J; Lu, Huangling; Vos, Nicola; IJsselmuiden, Alexander; van Geuns, Robert-Jan; Wessely, Rainer; Dengler, Thomas; La Manna, Alessio; Silvain, Johanne; Montalescot, Gilles; Spaargaren, René; Tijssen, Jan G P; de Winter, Robbert J; Wykrzykowska, Joanna J; Amoroso, Giovanni; Koch, Karel T
2017-08-01
To investigate outcomes in patients with ST-segment elevation myocardial infarction (STEMI) after treatment with the Stentys self-apposing stent (Stentys SAS; Stentys S.A.) for bifurcation culprit lesions. The nitinol, self-expanding Stentys was initially developed as a dedicated bifurcation stent. The stent facilitates a provisional strategy by accommodating its diameter to both the proximal and distal reference diameters and offering an opportunity to "disconnect" the interconnectors, opening the stent toward the side branch. The APPOSITION (a post-market registry to assess the Stentys self-expanding coronary stent in acute myocardial infarction) III study was a prospective, multicenter, international, observational study including STEMI patients undergoing primary percutaneous coronary intervention (PCI) with the Stentys SAS. Clinical endpoints were evaluated and stratified by bifurcation vs non-bifurcation culprit lesions. From 965 patients included, a total of 123 (13%) were documented as having a bifurcation lesion. Target-vessel revascularization (TVR) rates were higher in the bifurcation subgroup (16.4% vs 10.0%; P=.04). Although not statistically significant, other endpoints were numerically higher in the bifurcation subgroup: major adverse cardiac events (MACE; 12.7% vs 8.8%), myocardial infarction (MI; 3.4% vs 1.8%), and definite/probable stent thrombosis (ST; 5.8% vs 3.1%). However, when postdilation was performed, clinical endpoints were similar between bifurcation and non-bifurcation lesions: MACE (8.7% vs 8.4%), MI (1.2% vs 0.7%), and definite/probable ST (3.7% vs 2.4%). The use of the Stentys SAS was safe and feasible for the treatment of bifurcation lesions in the setting of primary PCI for STEMI treatment with acceptable 1-year cardiovascular event rates, which improved when postdilation was performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Funovics, M.A.; Lackner, B.; Cejna, M.
2002-10-15
Purpose: To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate the influence of vascular comorbidity, lesion length, stent placement and lesion coverage as possible predictors of outcome. Methods: Between January 1994 and December 1999, 80 iliac recanalizations were performed on 78 patients, median age 61.1 {+-}11.5 (SD) years. All patients were followed up by clinical examinations, duplex ultrasound and intravenous digital subtraction angiography. Mean follow-up time was 2.0 {+-} 1.53 (SD) years.Multivariate Cox regression analysis was used to determine the influence of cofactors on patency. Results: One, 2more » and 4 years after recanalization, primary patency was 78.1%, 74.5% and 64.0%; secondary patency was 88.8%, 88.8% and 77.9%, respectively.Patients with shorter occlusions, complete lesion coverage and patent ipsilateral femoral arteries had significantly longer patency rates.Complications included inguinal hematoma (n=1), technical failure (n=3) aortic dissection (n=1), embolic occlusions (n=7), gluteal claudication (n=1) and genital necrosis after subsequent urethral surgery in one patient with contralateral occlusion and ipsilateral overstenting of the internal iliac artery with subsequent stenosis. Complications were of permanent clinical significance in seven of 78 (9%) of the patients. In 17 (22%) cases, percutaneous reintervention was performed with angioplasty in the stent (n=16) or deployment of a new stent (n=1). Conclusion: Endoluminal stent placement has its place in an interdisciplinary therapeutic approach as a viable therapeutic alternative to major transabdominal bypass surgery and can be performed with comparable complication rates. Patients with short occlusions, patent femoral arteries, and stents covering the entire occlusion have significant longer patency.« less
Wilson, Jennifer L; Louie, Brian E; Farivar, Alexander S; Vallières, Eric; Aye, Ralph W
2013-12-01
Self-expanding fully covered metal stents (CSs) are ideal for use in benign esophagogastric disease. We reviewed our experience with CS to evaluate outcomes, to determine a role for CS in a standard treatment for benign esophageal conditions, and to compare our results with recently published studies. We performed a retrospective chart review from 2005 to 2012. A total of 57 CSs were placed in 44 patients. Indications were stricture (11 patients), anastomotic leak (20), perforation (7), and tracheoesophageal fistulae (6). For GI tract disruptions, open repair or diversion was avoided in 31/33 patients (93.9 %) but required an associated drainage procedure in 22/33 (67 %) patients. Resolution does not depend on achieving radiological control with 6/26 (23 %) having evidence of a persistent leak. Benign strictures were dilated at a mean of 3.7 times prior to stenting. Adjunctive intra-mucosal steroid injections were used in 8/11 patients. Stents were removed at a mean of 33 days. At a mean of 283 days of follow-up, 6/11 (54.5 %) had symptom resolution. The most common complication was stent migration occurring in 17.5 % of patients overall. Covered stents are an effective adjunct in the management of benign upper gastrointestinal tract fistulae, leaks, perforations and benign strictures.
Pokrovskiĭ, A V; Ignat'ev, I M; Volodiukhin, M Iu; Gradusov, E G
The present study was aimed at assessing initial results of hybrid operations in obstructive lesions of the iliac-femoral veins in patients with post-thrombotic disease (PTD). Hybrid operations [open endovenectomy from the common femoral vein (CFV) with creation of an arteriovenous fistula + stenting of iliac veins] were performed carried out in a total of eleven patients with PTD. Of these, there were 7 men and 4 women aged from 34 to 52 years (mean age - 42.8±7 years). All patients had severe-degree chronic venous insufficiency (CVI). The distribution of patients according to the CEAP classification was as follows: C4a - 2 patients, C4b - 4 patients, C5 - 4 subjects, C6 - 1 patient. The time having elapsed since a newly onset episode of acute iliac-femoral venous thrombosis varied from 2 to 12 years (averagely - 7.1±3.3 years). The degree of manifestation of PTD was determined by means of the Villalta-Pradoni scale before and 6 months after the operation. Instrumental methods of study included ultrasound duplex scanning (USDS), magnetic resonance and/or multispiral computed venography, and contrast-enhanced X-ray venography. The technical success of the procedure amounted to 91%. In one patient with occlusion of the common and external iliac veins we failed to perform recanalization and stenting. A further one patient developed in-stent and CFV thrombosis on the second postoperative day. An attempt of catheter thrombolysis turned out unsuccessful. There were no wound complications in the postoperative period. Neither was pulmonary artery thromboembolism registered. The dynamic control was carried out by means of USDS before discharge from hospital and at 1, 3 and 6 months after the intervention. The outcomes of hybrid operations after 6 months were followed up in five patients. Secondary patency rate of the stented iliac veins amounted to 100%. No relapses of trophic ulcers were observed. According to the Villalta-Prandoni scale the value of the median of the composite index decreased from 15 to 7 (p=0.012). The first experience with hybrid operations for obstructive lesions of veins of the iliac-femoral segment demonstrated their high efficacy and safety. Efficiency of the operation was confirmed by significant clinical improvement and good results of patency of the restored-repaired segments of veins.
Cumberland, D C; Gunn, J; Malik, N; Holt, C M
1998-01-01
The surface properties of stents can be modified by coating them, for example with a polymer. Phosphorylcoline (PC) is the major component of the outer layer of the cell membrane. The haemo- and biocompatibility of a PC-containing polymer is thus based on biomimicry, and has been confirmed by several experiments showing much reduced thrombogenicity of PC-coated surfaces, and porcine coronary artery implants showing no sign of adverse effect. Clinical experience with the PC-coated BiodivYsio appears favourable. The PC coating can be tailored for take up and controlled elution of various drugs for stent-based local delivery, a property which is being actively explored.
Yang, Juliana; Siddiqui, Ali A; Kowalski, Thomas E; Loren, David E; Khalid, Ammara; Soomro, Ayesha; Mazhar, Syed M; Rosé, Julian; Isby, Laura; Kahaleh, Michel; Kalra, Ankush; Sarkisian, Alex M; Kumta, Nikhil A; Nieto, Jose; Sharaiha, Reem Z
2017-03-01
Endoscopic placement of fully covered self-expanding metal stents (FCSEMS) to treat malignant dysphagia in patients with esophageal cancer significantly improves dysphagia; however, these stents have a high migration rate. To determine whether FCSEMS fixation using an endoscopic suturing device treated malignant dysphagia and prevented stent migration in patients with locally advanced esophageal cancer receiving neoadjuvant therapy when compared to patients with FCSEMS placement alone. A review of patients with locally advanced esophageal cancer who underwent FCSEMS placement at 3 centers was performed. Patients were divided into two groups: Group A (n = 26) was composed of patients who underwent FCSEMS placement with suture placement, and Group B (n = 67) was composed of patients with FCSEMS placement alone. There were no significant differences between Groups A and B in demographics, and tumor characteristics. The technical success rate for stent placement was 100 %. There was no difference between Groups A and B in the median stent diameter and stent lengths. Mean dysphagia score obtained at 1 week after stent placement had improved significantly from baseline (2.4 and 1, respectively, p < 0.001). Patients had a median follow-up of 4 months. Immediate adverse events were mild chest discomfort in 4 patients in Group A and 2 patients in Group B (p = 0.05), and significant acid reflux in 3 patient in Group A compared to 2 patients in Group B (p = 0.1). The stent migration rate was significantly lower in Group A compared to compared to Group B (7.7 vs 26.9 %, respectively, p = 0.004). There was a delayed perforation in 1 patient and 1 death due to aspiration pneumonia in Group B. Fixation of esophageal FCSEMSs by using an endoscopic suturing device in patients receiving neoadjuvant therapy was shown to be feasible, safe, and relatively effective at preventing stent migration compared to those who had stent placed alone.
Rijnberg, Friso M; Butler, Colin R; Speggiorin, Simone; Fierens, Anja; Wallis, Colin; Nouraei, Reza; McLaren, Clare A; Roebuck, Derek J; Hewitt, Richard; Elliott, Martin J
2015-01-01
This study describes the microbial colonization profile of the airway in children after slide tracheoplasty (STP) with and without stents, and compares colonization to children undergoing cardiothoracic surgical procedures without airway related disease. A 14-year retrospective single case note review was performed on patients undergoing STP and stent insertion. Nose and throat (NT) and bronchoalveolar lavage (BAL) specimens were analyzed for microbial profile and expressed as cumulative mean microorganisms per patient (MMP). Forty-three patients (median age ± SD 15.02 ± 31.76 months) underwent STP and 141 patients underwent cardiothoracic but no airway surgery (median age ± SD 31.7 ± 47.2 months). Sixteen patients required a stent after STP. One-hundred seventy-two positive microbial specimens were identified. The predominant 6 microorganisms were (1) Staphylococcus aureus; (2) Pseudomonas aeruginosa; (3) Haemophilus influenzae not type B; (4) Coliforms; (5) Streptococcus pneumoniae; and (6) Candida Albicans, and accounted for 128 (74%) of all positive specimens found. Children with stents had more MMP compared to children without stents after STP [4.06 ± 2.38 and 2.04 ± 2.24 MMP (P < 0.001), respectively]. Both groups of children after STP had more MMP compared to the control group (P < 0.001). Children with stents had more microbial colonization of their lower respiratory tract compared to their upper respiratory tract (3.36 ± 2.02 and 1.36 ± 0.93 MMP (P < 0.01) respectively). Staphylococcus aureus colonization of the lower respiratory tract was significantly higher in children with stents compared to children without stents after STP [0.5 and 0.15 MMP (P < 0.05) respectively]. This study indicates airway surgery and the subsequent use of stents to be a significant risk factor for microbial colonization of the airway in children. More specifically airway stents appear to increase colonization in the distal airway, which appears unrelated to that of the upper respiratory tract. © 2014 Wiley Periodicals, Inc.
Khan, Muhib; Qureshi, Adnan I
2014-01-01
Background and Purpose We provide an assessment of clinical, angiographic, and procedure related risk factors associated with stroke and/or death in patients undergoing carotid artery stent placement which will assist in patient stratification and identification of high-stent risk patients. Methods A comprehensive search of Medline from January 1st 1996 to December 31st 2011 was performed with key words “carotid artery stenosis”, “ carotid artery stenting”, “carotid artery stent placement”, “death” , ” mortality”, “stroke”, “outcome”, “clinical predictors”, “angiographic predictors”, was performed in various combinations. We independently abstracted data and assessed the quality of the studies. This analysis led to the selection of 71 articles for review. Results Clinical factors including age≥80 years, symptomatic status, procedure within 2 weeks of symptoms, chronic renal failure, diabetes mellitus, and hemispheric TIA were associated with stroke (ischemic or hemorrhagic) and death within 1 month after carotid artery stent placement. Angiographic factors including left carotid artery intervention, stenosis > 90%, ulcerated and calcified plaques, lesion length > 10mm, thrombus at the site, ostial involvement, predilation without EPD, ICA-CCA angulation > 60%, aortic arch type III, and aortic arch calcification were also associated with 1 month stroke and/or death. Intra-procedural platelet GP IIb/IIIa inhibitors, protamine use, multiple stents, predilatation prior to stent placement were associated with stroke (ischemic or hemorrhagic) and death after carotid artery stent placement. Intraprocedural use of embolic protection devices and stent design (open versus closed cell design) did not demonstrate a consistent relationship with 1 month stroke and/or death. Procedural statin use, and operator and center experience of more than 50 procedures per year were protective for 1 month stroke and/or death. Conclusions Our review identified risk factors for stroke, death, and MI within 1 month in patients undergoing carotid artery stent placement. Such information will result in better patient selection for carotid artery stent placement particularly in those who are also candidates for carotid endarterectomy. PMID:24920983
Premat, Kévin; Bartolini, Bruno; Baronnet-Chauvet, Flore; Shotar, Eimad; Degos, Vincent; Muresan, Paul; Di Maria, Federico; Gabrieli, Joseph; Rosso, Charlotte; Pistocchi, Silvia; Chiras, Jacques; Sourour, Nader; Alamowitch, Sonia; Samson, Yves; Clarençon, Frédéric
2017-05-15
Most recent guidelines recommend the use of stent retriever devices in endovascular treatment of acute ischemic stroke with large vessel occlusion (LVO). Recently published data reported convincing results with thromboaspiration devices such as the Penumbra System (Penumbra, Alameda, CA, USA) combined with supple reperfusion catheters by using the ADAPT (A Direct Aspiration First-Pass Thrombectomy) technique. The aim of this study was to report our initial experience with the 3MAX (3.8 F) reperfusion catheter for the recanalization of distal intracranial arteries. From August 2015 to December 2016, 32 consecutive patients (16 females, 50%; mean age = 67.4 ± 18.7 years, range: 22-91) for 38 distal occlusions underwent mechanical thrombectomy (MT) by thromboaspiration using the 3MAX. Median NIHSS score at admission was 14 (IQR: 9-19). Distal occlusions were distributed as follows: M2 (n: 23), M3 (n: 6), P1 (n: 3), P2 (n: 2), P3 (n: 2), A3 segment (n: 1) and superior cerebellar artery (n: 1). In 1/38 (2.6%) target artery, the 3MAX could not be navigated. Of the 37 (59.5%) remaining arteries, 22 were successfully reperfused (TICI 2b/3) after ADAPT with the 3MAX alone. Additional stent retriever thrombectomy allowed a 76.3% final reperfusion rate. Good functional outcome (mRS ≤2) was obtained in 45.5% of patients at 3 months. Three (9.4%) 3MAX-related complications occurred: 2 emboli to new territory (ENT) and one vascular perforation. The 3MAX is well-navigable in distal arteries making it useful as a frontline technique. However, the reperfusion rate with the 3MAX catheter alone seems lower than the ones reported with stent retrievers for such distal occlusions.
Jakob, H.; Oelert, H.; Schmiedt, W.; Teusch, P.; Iversen, S.; Hake, U.; Schild, H.; Maass, D.
1989-01-01
Fourteen patients with complicated venous thrombosis or recurrent pulmonary embolism were treated by implantation of an endoluminal spiral prosthesis subsequent to balloon angioplasty, surgical thrombectomy or embolectomy, a combination of these, or, in 2 cases, no other treatment. The patients were divided into 2 groups, based on their primary diagnosis and the purpose of the prosthesis. Group I included 8 patients with extensive iliofemoral or caval thrombosis, caused by congenital caval stenosis (1 case) or extravascular compression or retraction (7 cases); 7 of these patients had had previous operations, and the remaining patient had undergone thrombolysis, which failed. The current treatment consisted of balloon angioplasty and surgical thrombectomy or embolectomy, and implantation of an endoluminal spiral stent to prevent elastic recoil of the vessel. In 4 cases, an arteriovenous fistula was constructed and was taken down 3 months later; in 1 additional patient, a bilateral arteriovenous fistula was created. Group II comprised 6 patients with recurrent pulmonary embolism (4 cases), massive pulmonary embolism (1 case), or paradoxical bilateral carotid artery embolism (1 case). Four of these patients underwent surgical thrombectomy or embolectomy, while 2 had no treatment other than filter implantation. All 6 underwent transluminal implantation of a helix caval filter (a modification of the endoluminal spiral stent). All but 1 implantation was accomplished by means of either a transfemoral or a transjugular cutdown; the remaining implantation was performed transatrially after a pulmonary embolectomy. The only device-related complication was a retroperitoneal hematoma in Group I, resulting from perforation of the inferior vena cava by the guidewire during device implantation. This complication necessitated an emergency laparotomy and takedown of the arteriovenous fistula, which resulted in rethrombosis of the left iliofemoral vein. The other 7 stented veins were patent at early phlebographic follow-up, as were all 5 of those studied later. One Group-I patient died 4 months after surgery, due to tumor progression and without signs of caval restenosis. Twelve months postoperatively, 1 Group-II patient died of urosepsis without a recurrence of pulmonary embolism. Four of the 6 Group-II patients were studied late postoperatively, and all of their stented vessels were patent. There was no operative mortality or postoperative embolism. On the basis of these results, we conclude that endoluminal stenting with an expandable spiral prosthesis is a promising method for remote venous reconstruction. Moreover, it appears that the modified stent, or helix caval filter, compares favorably with commercially available filters. (Texas Heart Institute Journal 1989;16:87-94) Images PMID:15227219
Li, Xun; He, Zhaohui; Yuan, Jian; Zeng, Guohua; He, Yongzhong; Lei, Ming
2007-08-01
The management of complicated benign upper urinary tract occlusion is extremely challenging, especially in patients unable to undergo an open operative procedure. We report the long-term results of a permanent metallic stent for benign upper urinary tract occlusion. From October 1995 to December 1998, 13 patients (8 men and 5 women, with a mean age of 43 years) with benign upper tract occlusion have been treated by metallic stent implantation. All patients had a nephrostomy tube to relieve the obstruction and the average time of the nephrostomy tube stay was 27 months, ranging from 3 to 131 months. The average length of occlusion was 2.7 cm, ranging from 1 to 3.6 cm. Ultrasonography, urography, diuresis renography and urine culture were performed every 3 months after stent insertion. Ureteroscopy was done when needed. The mean follow-up was 92 months (12-132 months). Ureteral patency was achieved in six patients and assisted patency with a Double-J stent was achieved in three patients. In two patients the kidney had to be removed because of progressive malfunction and in two patients the metal stent had to be extracted with the Holmium: YAG laser, burning it down due to the uncontrollable pyonephrosis. In three patients the ipsilateral flank pain recurred. One of these patients experienced urine leakage due to the initial nephrostomy tract: a ureteroscopy revealed a complete hyperplastic urothelial response. Proximal stone formations were found in 2 patients and all were removed by percutaneous nephrolithotomy (PCNL). No stent migration or fragmentation was observed. The implantation of metal stent is a safe and effective treatment for benign upper urinary tract occlusion, and has satisfying long-term outcome in selected cases. A further investigation is needed for its impact on the urodynamics of upper urinary tract.
Cools, Bjorn; Brown, Stephen C; Heying, Ruth; Jansen, Katrijn; Boshoff, Derize E; Budts, Werner; Gewillig, Marc
2015-01-01
Pulmonary regurgitation (PR) following surgery of the right ventricular outflow tract (RVOT) is not innocent and leads to significant right heart dysfunction over time. Recent studies have demonstrated that percutaneous valves can be implanted in conduit free outflow tracts with good outcomes. To evaluate in patients with severe PR--anticipated to require future pulmonary valve replacement--the feasibility and safety of pre-stenting dilated non-stenotic patched conduit-free right ventricular outflow tracts before excessive dilation occurs, followed by percutaneous pulmonary valve implantation (PPVI). Twenty seven patients were evaluated, but only 23 were deemed suitable based on the presence of an adequate retention zone ≤ 24 mm defined by semi-compliant balloon interrogation of the RVOT. A 2 step procedure was performed: first the landing zone was prepared by deploying a bare stent, followed 2 months later by valve implantation. RVOT pre-stenting with an open cell bare metal stent (Andrastent XXL range) was performed at a median age of 13.0 years (range: 6.0-44.9) with a median weight of 44.3 kg (range: 20.0-88.0). Ninety six percent (22/23) of patients proceeded to PPVI a median of 2.4 months (range: 1.4-3.4) after initial pre-stent placement. Twenty one Melody valves and one 26 mm Edwards SAPIEN™ valve were implanted. Complications consisted of embolization of prestent (n = 1), scrunching (n = 4) and mild stent dislocation (n = 2). During follow-up, no stent fractures were observed and right ventricular dimensions decreased significantly. Post-surgical conduit-free non-stenotic RVOT with free pulmonary regurgitation can be treated percutaneously with a valved stent if anatomical (predominantly size) criteria are met. In experienced hands, the technique is feasible with low morbidity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Randomized trial in malignant biliary obstruction: Plastic vs partially covered metal stents
Moses, Peter L; AlNaamani, Khalid M; Barkun, Alan N; Gordon, Stuart R; Mitty, Roger D; Branch, M Stanley; Kowalski, Thomas E; Martel, Myriam; Adam, Viviane
2013-01-01
AIM: To compare efficacy and complications of partially covered self-expandable metal stent (pcSEMS) to plastic stent (PS) in patients treated for malignant, infrahilar biliary obstruction. METHODS: Multicenter prospective randomized clinical trial with treatment allocation to a pcWallstent® (SEMS) or a 10 French PS. Palliative patients aged ≥ 18, for infrahilar malignant biliary obstruction and a Karnofsky performance scale index > 60% from 6 participating North American university centers. Primary endpoint was time to stent failure, with secondary outcomes of death, adverse events, Karnofsky performance score and short-form-36 scale administered on a three-monthly basis for up to 2 years. Survival analyses were performed for stent failure and death, with Cox proportional hazards regression models to determine significant predictive characteristics. RESULTS: Eighty-five patients were accrued over 37 mo, 42 were randomized to the SEMS group and 83 patients were available for analyses. Time to stent failure was 385.3 ± 52.5 d in the SEMS and 153.3 ± 19.8 d in the PS group, P = 0.006. Time to death did not differ between groups (192.3 ± 23.4 d for SEMS vs 211.5 ± 28.0 d for PS, P = 0.70). The only significant predictor was treatment allocation, relating to the time to stent failure (P = 0.01). Amongst other measured outcomes, only cholangitis differed, being more common in the PS group (4.9% vs 24.5%, P = 0.029). The small number of patients in follow-up limits longitudinal assessments of performance and quality of life. From an initially planned 120 patients, only 85 patients were recruited. CONCLUSION: Partially covered SEMS result in a longer duration till stent failure without increased complication rates, yet without accompanying measurable benefits in survival, performance, or quality of life. PMID:24379581
[Internal drainage in cancer patients: optimizing treatment of stent-related symptoms].
Martov, A G; Ergakov, D V; Novikov, A B; Muzhetskaya, N G; Esen'yan, G L
2016-04-01
The so-called stent-related symptoms caused mainly by detrusor overactivity due to distal ("cystic") curl of the internal stent are common among patients with this type of drainage. The need for long-term stenting makes the quality of life of cancer patients one of the challenging problems of modern urology. The aim of this study was to optimize treatment of stent-related symptoms in cancer patients with internal long-term stents by complementing the treatment regimen with m-anticholinergic solifenacin. From November 2013 to November 2015 68 cancer patients (26 males, 42 females, age 36-79 years) underwent elective internal ureteral stenting for drainage of the upper urinary tract (UUT) with special long-term stents coated with the hydrogel. The urinary tract obstruction was caused by urological (24), gynecological (26) and colorectal (18) cancers. Before deciding on urinary tract drainage, all patients were treated with radiation or chemotherapy, 28 (41.2%) patients underwent surgery, but on admission all of them had contraindications to radical surgery for different reasons. In 52 (76.5%) patients UUT stenting was performed using transurethral access, in 12 (17.6%) by percutaneous access and in another 4 (5.9%) by the combined access with patients in the supine position. Percutaneous and combined access was used in cases of impracticability (failure) of transurethral stenting. Patients in group 1 (n=32) after stent placement received standard therapy co-administered with solifenacin 5 mg daily, group 2 (n=36) - only standard therapy. The data analyzed were the technical features of the internal drainage, optimal access and registered solifenacin-related adverse events. Control examinations were scheduled once in 3 months after stent placement according to the following algorithm: ultrasound scanning, laboratory test monitoring and, if indicated, plain urography. To objectify the severity of stent-related symptoms, a survey of patients using a special questionnaire was conducted. Visual analog scale was used to measure subjectively the patients condition. After 12 months only 48 patients (26 from group 1 and 22 from group 2) completed the study. Follow-up examinations revealed that the patients in group 1 had significantly lower score of stent-related symptom severity and better ratings in visual analog scale. The greatest difference (1-2 points) was found in urgency and urinary frequency scores. The safety profile of solifenacin 5 mg corresponded to the findings of previous studies, there was no serious adverse events requiring discontinuation of the drug. Installing internal stents in UUT in cancer patients requires relevant experience in Roentgen-endoscopic operations using transurethral and percutaneous approaches and special equipment. In most cases, for preventing and eliminating supravesical obstruction in cancer patients, special internal stents for the long term placement are required. The add-on solifenacin therapy 5 mg/day resulted in almost 20% reduction in the severity of stent-related irritative symptoms and improved the quality of life in this extremely challenging category of patients.
Long-term Outcome of Short Metallic Stents for Lobar Airway Stenosis.
Fruchter, Oren; Abed El Raouf, Bayya; Rosengarten, Dror; Kramer, Mordechai R
2017-07-01
Whereas stents are considered an excellent treatment for proximal central major airway stenosis, the value of stenting for distal lobar airway stenosis is still controversial. Our aim was to explore the short-term and long-term outcome of metallic stents placed for benign and malignant lobar airway stenosis. Between July 2007 and July 2014, 14 patients underwent small airway stent insertion. The clinical follow-up included serial semiannual physical examinations, pulmonary function tests, imaging, and bronchoscopy. The etiologies for airway stenosis were: early post-lung transplantation bronchial stenosis (N=5), sarcoidosis (N=1), amyloidosis (N=1), anthracofibrosis (N=1), right middle lobe syndrome due to external lymph node compression (N=1), lung cancer (N=4), and stenosis of the left upper lobe of unknown etiology (N=1). Stents were placed in the right upper lobe bronchus (N=2), right middle lobe bronchus (N=6), left upper lobe bronchus (N=4), linguar bronchus (N=1), and left lower lobe bronchus (N=1). The median follow-up period ranged from 2 to 72 months (median 18 mo). Immediate relief of symptoms was achieved in the vast majority of patients (13/14, 92%). Out of 10 patients with benign etiology for stenosis, 9 (90%) experienced sustained and progressive improvement in pulmonary function tests and clinical condition. We describe our positive experience with small stents for lobar airway stenosis; further prospective trials are required to evaluate the value of this novel modality of treatment.
Beusterien, Kathleen M; Plante, Kathryn M; Waksman, Ron; Raizner, Albert E; Annis, Marijke; Goss, Thomas F
2002-01-01
We studied the cost-effectiveness of percutaneous coronary intervention (PCI) plus beta-radiation (Radiotherapy) vs. PCI alone for treating in-stent restenosis. We analyzed medical resource data collected at US sites during the Intimal Hyperplasia Inhibition with beta In-stent Trial (INHIBIT) to compare the incremental costs between Radiotherapy and PCI alone for each repeat target lesion revascularization (TLR) avoided. Costs were assigned for cardiac-related medical services using the Medicare payer perspective. Radiotherapy increased initial inpatient costs by US$3360 (P<.001). In the Radiotherapy and PCI alone groups, the mean per-patient rates for TLR were 0.13 vs. 0.30 (P=.001), and mean per-patient total costs were US$19,286 vs. US$18,349 (P<.001), respectively. The incremental cost of Radiotherapy relative to PCI alone was US$5512 per TLR avoided, which compares favorably to the observed mean per-patient cost of treating restenosis (US$16,852). beta-radiation is a cost-effective adjunct to PCI in treating patients with in-stent restenosis.
Covered stent graft for treatment of a pseudoaneurysm and carotid blowout syndrome
Janjua, Nazli; Alkawi, Ammar; Georgiadis, Alexandros L.; Kirmani, Jawad F.; Qureshi, Adnan I.
2008-01-01
Background Carotid blowout syndrome with pseudoaneurysm, a rapidly progressive pathology, may present emergently with massive oral hemorrhage. Use of an endograft prosthesis offers a treatment strategy with salvation of the carotid artery. Case History: A 55 year old man with advanced squamous cell carcinoma of the head and neck presented with recurrent transoral hemorrhage, requiring endovascular treatment. Technical Report: Coil embolization was initially performed with little impact on the hemorrhage. A 7 x 40 mm Fluency® Plus covered stent (Bard Peripheral Vascular, Tempe, Arizona, USA) was placed and was supplemented by a second 8 x 40 mm Fluency Plus stent, with resulting cessation of active contrast extravasation. Discussion: The risks and benefits of various treatment options of carotid pseudoaneurysm with blowout are discussed including the use or omission of antiplatelet and anticoagulant regimens, with reference to previously reported cases. Conclusion: Tandem, overlapping covered stent placement in the common carotid artery is feasible and offers a treatment option for carotid blowout syndrome. Risks of aggravation of hemorrhage versus long-term thromboembolic events without antiplatelet therapy must be considered in cases of active ongoing hemorrhage. PMID:22518207
Anderloni, Andrea; Genco, Chiara; Massidda, Marco; Di Leo, Milena; Fumagalli, Uberto Romario; Rosati, Riccardo; Correale, Loredana; Maselli, Roberta; Ferrara, Elisa Chiara; Jovani, Manol; Repici, Alessandro
2018-06-05
The study aimed to evaluate the effectiveness and safety of self-expanding metal stents (SEMS) in the management of post-surgical esophageal leaks. Retrospective data of consecutive patients with a post-surgical esophageal leak treated by means of a metal stent between January 2008 and December 2014 at the Humanitas Research Hospital (Milan, Italy) were extracted from a prospectively maintained register of SEMS used for benign indications, such as post-surgical benign esophageal strictures and/or leaks. The primary outcome of the study was to assess the rate of successful leak closure and to identify the variables associated with its achievement. As a secondary outcome, we evaluated the overall safety of SEMS placement and the efficacy and safety for different types of SEMS in this specific setting of patients. Leak resolution was documented with endoscopic and/or imaging studies. In the case of leak persistence, further attempts of esophageal stenting were carried out at the discretion of both endoscopists and surgeons. A total of 49 patients were included in the study (men 41 of 49, 83.7%, mean age 62.4 ± 11.9). One patient was excluded from analysis, because of death 1 day after stent insertion due to worsening of pre-existing mediastinitis. A total number of 82 stents were placed (mean number of stents per patient: 1.7) in 49 patients: 35 patients (71.4%) received a partially covered SEMS (PCSEMS) as the first stent positioned, while the remaining 14 (28.6%) received a fully covered SEMS (FCSEMS); but 1 patient (2%) died following stent insertion; therefore, data regarding therapeutic success were available for 48 patients. Stents were left in place for a mean period of 21.9 ± 15.2 days. Leak closure after the first stent placement was achieved in 22 of 48 (45.8%) patients. Of the 26 patients with failure of index stent placement, 18 patients underwent further stenting attempts (69.2%), and secondary closure of leak was achieved in 7 (38.9%) of these 18 patients. Thus, the overall success rate was 60.5% (29 of 48). On the basis of stent type, the success rate was 57.1% (8 of 14) for FCSEMS and 64.7% (22 of 34) for PCSEMS. Logistic regression analysis did not find any significant association between successful leak closure and analyzed variables. Overall mortality was 13.0%. Complication rate was 38.8% (19 of 49 patients). The use of SEMS is an effective and safe option for post-surgical esophageal leaks, with no evidence of any significant influence of stent type on outcome. © 2018 S. Karger AG, Basel.
Berger, H; Gärtner, C; Kohz, P; Stäbler, A; Dienemann, H; Wilmes, E
1993-07-01
Narrowing of the trachea due to tracheomalacia or compression can lead to life-threatening asphyxia and may require tracheotomy with intubation or endoscopic introduction of a stent. The use of a self-expanding elastic metal prosthesis in 4 patients with airway obstruction has proved a satisfactory alternative to conventional plastic prostheses, both in the acute phase and over a long period of time. After 4 weeks total epithelium cover of the stent could be demonstrated; biopsies after 3 and 4 months showed differentiation into respiratory ciliated epithelium. Patient acceptance was excellent since there was no sensation of a foreign body, retention of secretions or cough. The physical properties of the wall stent made it a suitable mechanical replacement for an unstable or narrowed trachea during the period of observation.
Biodegradable Stents for Caustic Esophageal Strictures: Do They Work?
Kochhar, Rakesh; Samanta, Jayanta; Basha, Jahangeer; Verma, Abhai; Choudhuri, Gourdas; Lakhtakia, Sundeep; Reddy, D Nageshwar
2017-08-01
Biodegradable (BD) stents have been used for the management of various esophageal strictures (ES) but the experience of its use in caustic strictures is limited. The present study, aimed at evaluating efficacy of BD stents for the treatment of refractory caustic-induced ES, was a retrospective multi-center study conducted at three tertiary care centers in India wherein adult patients with refractory caustic induced strictures underwent placement of a BD stent. Patients were followed up for immediate complications and long term outcome. All 13 patients (39.3 ± 15.1 years) underwent successful BD stent placement. Retrosternal chest pain occurred in 2 patients and stent migration in 1 (7.6%) patient. At 3 months, restenosis with recurrence of dysphagia was seen in nine (69.2%) patients, at 6 months, 10 (77%) patients had dysphagia of whom three underwent surgery and the remaining seven patients required dilatations. At 1 year, one patient remained asymptomatic while nine had dysphagia. The requirement for dilatation was once in 3 months in seven patients & once in a month in two patients. At 2 years, the requirement of dilatations was further reduced to once in 4-6 months in all patients. Over a 3 year follow up three (23%) patients had undergone surgery, one was free of symptoms while nine patients continued to be on periodic dilatation although the requirement had reduced to once in 4-6 months. Efficacy of BD stents in patients with caustic-induced ES is limited and the short term radial force applied by the currently available BD stents is inadequate to provide long term relief in such patients.
Dynamic simulation of stent deployment - effects of design, material and coating
NASA Astrophysics Data System (ADS)
Schiavone, A.; Zhao, L. G.; Abdel-Wahab, A. A.
2013-07-01
Dynamic finite-element simulations have been carried out to study the effects of cell design, material choice and drug eluting coating on the mechanical behaviour of stents during deployment. Four representative stent designs have been considered, i.e., Palmaz-Schatz, Cypher, Xience and Endeavor. The former two are made of stainless steel while the latter two made of Co-Cr alloy. Geometric model for each design was created using ProEngineer software, and then imported into Abaqus for simulation of the full process of stent deployment within a diseased artery. In all cases, the delivery system was based on the dynamic expansion of a polyurethane balloon under applied internal pressure. Results showed that the expansion is mainly governed by the design, in particular open-cell design (e.g. Endeavor) tends to have greater expansion than closed-cell design (e.g. Cypher). Dogboning effect was strong for slotted tube design (e.g. Palmaz-Schatz) but reduced significantly for sinusoidal design (e.g. Cypher). Under the same pressure, the maximum von Mises stress in the stent was higher for the open-cell designs and located mostly at the inner corners of each cell. For given deformation, stents made of Co-Cr alloys tend to experience higher stress level than those made of stainless steels, mainly due to the difference in material properties. For artery-plaque system, the maximum stress occurred on the stenosis and dogboning led to stress concentration at the ends of the plaque. The drug eluting coating affected the stent expansion by reducing the recoiling phenomenon considerably, but also raised the stress level on the stent due to property mismatch.
Parodi, Andrea; De Ceglie, Antonella; De Luca, Luca; Conigliaro, Rita; Naspetti, Riccardo; Arpe, Paola; Coccia, Gianni; Conio, Massimo
2016-11-01
Compared to emergency surgery, self-expandable metallic stents are effective and safe when used as bridge-to-surgery (BTS) in operable patients with acute colorectal cancer obstruction. In this study, we report data on the new conformable colonic stents. To evaluate clinical effectiveness of conformable stents as BTS in patients with acute colorectal cancer obstruction. This was a retrospective study. The study was conducted at six Italian Endoscopic Units. Data about patients with acute malignant colorectal obstruction were collected between 2007 and 2012. All patients were treated with conformable stents as BTS. Technical success, clinical success, rate of primary anastomosis and colostomy, early and late complications were evaluated. Data about 88 patients (62 males) were reviewed in this study. Conformable SEMS were correctly deployed in 86 out of 88 patients, with resolution of obstruction in all treated patients. Tumor resection with primary anastomosis was possible in all patients. A temporary colostomy was performed in 40. Early complications did not occur. Late complications occurred in 11 patients. Stent migration was significantly higher in patients treated with partially-covered stents compared to the uncovered group (35% vs. 0%, P<0.001). Endoscopical re-intervention was required in 12% of patients. One patient with rectal cancer had an anastomotic dehiscence after surgery and he was successfully treated with endoscopic clipping. One year after surgery, all patients were alive and local recurrence have not been documented. This was a retrospective and uncontrolled study. Preliminary data from this large case series are encouraging, with a high rate of technical and clinical success and low rate of clinically relevant complications. Partially-covered SEMS should be avoided in order to reduce the risk of endoscopic re-intervention. Copyright © 2016. Published by Elsevier Masson SAS.
Dutau, Hervé; Breen, David Patrick; Gomez, Carine; Thomas, Pascal Alexandre; Vergnon, Jean-Michel
2011-02-01
Stump dehiscence after pneumonectomy is a cause of morbidity and mortality in patients treated for non-small-cell lung carcinoma. Surgical repair remains the treatment of choice but can be postponed or contraindicated. Bronchoscopic techniques may be an option with curative intent or as a bridge towards definitive surgery. The aim of the study is to evaluate the efficacy and the outcome of a new customised covered conical self-expandable metallic stent in the management of large bronchopleural fistulas complicating pneumonectomies. A case series using chart review of non-operable patients presenting with large bronchopleural fistulas (>6mm) post-pneumonectomies as a definitive treatment with curative intent for non-small-cell lung carcinomas and requiring the use of a dedicated conical shaped stent in two tertiary referral centres. Seven patients presenting large post-pneumonectomy fistulas (between 6 and 12 mm) were included. Cessation of the air leak and clinical improvement was achieved in all the patients after stent placement. Stent-related complications (two migrations and one stent rupture) were successfully managed using bronchoscopic techniques in two patients and surgery in one. Mortality, mainly related to overwhelming sepsis, was 57%. Delayed definitive surgery was achieved successfully in three patients (43%). This case series assesses the short-term clinical efficacy of a new customised covered conical self-expandable metallic stent in the multidisciplinary management of large bronchopleural fistulas complicating pneumonectomies in patients deemed non-operable. Long-term benefits are jeopardised by infectious complications. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Lubicz, Boris; Kadou, Alexandre; Morais, Ricardo; Mine, Benjamin
2017-03-01
The Leo stent was the first retrievable stent for endovascular treatment of intracranial aneurysms (IAs). We report our experience with this device with emphasis on very long-term follow-up. This study was approved by authors' ethical committee. A retrospective review of our prospectively maintained database identified all patients treated for a saccular IA with this stent in our institution. Technical issues and immediate and long-term outcomes (at least 12 months) were evaluated. Between 2004 and 2015, 50 patients with 52 IAs were identified. In two patients, the stent could not safely be placed (failure rate = 3.8%). Among 48 treated patients with 50 IAs, there were 44 women and 4 men (mean age, 53 years). Mean aneurysm diameter was 7.2 mm. All IAs but six were wide-necked. There was no immediate morbidity or mortality. Anatomical results included 76% complete occlusions, 22% neck remnants, and 2% incomplete occlusions. Mean follow-up was 50.2 months (range, 12-139 months). Two patients had delayed TIAs but long-term morbidity rate remained = 0%. At follow-up, occlusion was stable in 68% IAs, showed thrombosis in 12%, and recanalization in 20% IAs. Complementary treatment was required in 8% IAs. Final results showed 70% complete occlusions, 24% neck remnants, and 6% incomplete occlusions. Asymptomatic stent occlusion and significant stenosis occurred in one and two cases, respectively. The Leo stent is safe and effective for treatment of wide-necked saccular IAs. Very long-term results show high rates of adequate and stable occlusion. Moreover, the stent is well tolerated.
Lee, Sahmin; Yoon, Chang-Hwan; Oh, Il-Young; Suh, Jung-Won; Cho, Young-Seok; Cho, Goo-Yeong; Chae, In-Ho; Choi, Dong-Ju; Youn, Tae-Jin
2015-01-01
The angiographic features of restenosis contain prognostic information. However, restenosis patterns of the new generation drug-eluting stents (DES), everolimus-(EES) and resolute zotarolimus-eluting stent (ZES) have not been described.A total of 210 consecutive patients with DES restenosis were enrolled from 2003 to 2012. We analyzed 217 restenotic lesions after DES implantation, and compared the morphologic characteristics of the 2nd generation DES restenosis to those of restenosis with 2 first generation DES, sirolimus-(SES) and paclitaxel-eluting stent (PES).Baseline characteristics were comparable between the different stent groups. The incidence of focal restenosis was significantly lower for PES than the other stents (49.5% versus 87.0%, 76.2%, and 82.1% for PES versus SES, EES, and ZES, respectively, P < 0.001). When considering the pattern of restenosis solely within the stent margins, a further clear distinction between PES and other stents was observed (40.0% versus 92.9%, 88.9%, and 81.2% in PES versus SES, EES, and ZES, respectively, P < 0.001). There were no significant differences in restenosis patterns among SES, EES, and ZES. In multivariate analysis, PES implantation, hypertension, and age were associated with non-focal type of restenosis after DES implantation. After the introduction of EES and ZES into routine clinical practice in 2008, focal restenosis significantly increased from 63.9% to 76.7% and diffuse restenosis significantly decreased from 26.4% to 11.0% (P = 0.045).Focal restenosis was the most common pattern of restenosis in the new generation DES and the incidence of diffuse restenosis significantly decreased with the introduction of the 2nd generation DES.
Kim, Anthony W; Liptay, Michael J; Snow, Norman; Donahue, Philip; Warren, William H
2008-06-01
The objective of this study was to review the clinical experience of temporarily placing an endoesophageal silicone salivary bypass stent and its value in managing patients with life-threatening esophageal disruptions. Clinical records of patients undergoing placement of silicone Montgomery salivary bypass stents from June 1998 to September 2007 were reviewed. Seventeen patients had a proven esophageal disruption in the absence of malignancy and with life-threatening sepsis refractory to conventional management. Underlying conditions were iatrogenic trauma from prior pulmonary surgery (4 patients), significant anastomotic leaks after an esophagogastrectomy (4 patients), delayed presentation (> 24 hours) of a perforated esophagus (4 patients), leak after esophageal surgery (3 patients), and esophagobronchial fistula secondary to inflammation and infection (2 patients). Stents were placed without securing, were sutured in place to the esophageal wall at the time of thoracotomy, or were secured by bringing holding sutures through the nostrils and tied over the bridge of the nose. In all cases, placement of the esophageal stent led to prompt improvement of the leak and, within a week, improvement of the sepsis. Supportive measures were continued after placement of the stent. Sixteen patients overcame the sepsis with ultimate healing of the esophageal disruption (13 patients) or maturation of the perforation into a chronic fistula (3 patients). Endoscopic stent removal was performed 2 to 16 weeks after placement. No patient had a stricture develop at the disruption site. One patient died of ruptured thoracic aorta. Silicone salivary bypass stents serve as an effective way of diverting and excluding the oral-alimentary stream, thereby providing optimal conditions for sepsis control. They are a useful adjunct in the management of complex esophageal conditions.
Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.
Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R
2012-02-01
Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.
Metallic stents in the management of ureteric strictures
Kulkarni, Ravi
2014-01-01
Management of ureteric strictures is a challenging task. Subtle presentation, silent progression and complex aetiology may delay diagnosis. A wide range of available treatment options combined with the lack of adequate randomised trials has led to the introduction of personal bias in the management of this difficult group of patients. Metallic ureteric stents offer an alternative to the conventional treatment modalities. A review of the currently available metallic stents and their role in the long-term management of ureteric strictures is presented. Materials used in the manufacture of indwelling urological devices are evolving all the time. Improved endo-urological techniques combined with new devices made from better compounds will continue to improve patient experience. PMID:24497686
Late-onset severe biliary bleeding after endoscopic pigtail plastic stent insertion.
Yasuda, Muneji; Sato, Hideki; Koyama, Yuki; Sakakida, Tomoki; Kawakami, Takumi; Nishimura, Takeshi; Fujii, Hideki; Nakatsugawa, Yoshikazu; Yamada, Shinya; Tomatsuri, Naoya; Okuyama, Yusuke; Kimura, Hiroyuki; Ito, Takaaki; Morishita, Hiroyuki; Yoshida, Norimasa
2017-01-28
Here, we report our experience with a case of severe biliary bleeding due to a hepatic arterial pseudoaneurysm that had developed 1 year after endoscopic biliary plastic stent insertion. The patient, a 78-year-old woman, presented with hematemesis and obstructive jaundice. Ruptured hepatic arterial pseudoaneurysm was diagnosed, which was suspected to have been caused by long-term placement of an endoscopic retrograde biliary drainage (ERBD) stent. This episode of biliary bleeding was successfully treated by transarterial embolization (TAE). Pseudoaneurysm leading to hemobilia is a rare but potentially fatal complication in patients with long-term placement of ERBD. TAE is a minimally invasive procedure that offers effective treatment for biliary bleeding.
Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.
2016-01-01
Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614
Biebl, Matthias; Oldenburg, W Andrew; Paz-Fumagalli, Ricardo; McKinney, J Mark; Hakaim, Albert G
2004-11-01
Chronic mesenteric ischemia (CMI) can be treated with surgical revascularization or with angioplasty and stenting. As experience has been gained, endovascular treatment appears safe and effective in selected patients. Currently, surgical revascularization has better success and patency rates but also a higher short- and midterm mortality and morbidity, especially in patients at high surgical risk. A 72-year-old female with severe respiratory dysfunction presented with CMI resulting in profound malnutrition. Serial percutaneous interventions averted urgent surgery and reversed the mesenteric ischemia. Nine months later, after repeated angioplasty and stenting had failed, elective uncomplicated iliomesenteric bypass, in a medically optimized patient, resolved the ischemia. At an 18-month follow-up, the graft remained widely patent and the patient asymptomatic with a body weight corresponding to her ideal body weight. Compared to surgical revascularization, reocclusion or restenosis occurs more frequently after endovascular treatment of CMI, and reintervention may be necessary. Nevertheless, percutaneous intervention effectively provides relief from mesenteric ischemia and has lower perioperative complication rates compared to surgery in patients at high surgical risk. After initial relief of the CMI, the patient's condition may improve, allowing for more definitive secondary surgical revascularization, if needed.
Meditations on secondary revascularisation in the aftermath of the SYNTAX trial.
Garg, Scot; Serruys, Patrick W
2009-05-01
Many patients will experience a return of symptoms after their initial revascularisation procedure necessitating secondary revascularisation (SR). The options for this second procedure are inherently influenced by the primary method adopted for revascularisation. Patients with single vessel disease are most suited to percutaneous coronary intervention (PCI) for both primary and secondary revascularisation. The arrival of drug eluting stents, and evidence from trials of highly select populations has threatened the place of coronary artery bypass grafting (CABG) as the preferred method of revascularisation in those with multivessel disease. At present, and without robust evidence, PCI is increasingly being used to treat highly complex lesions, such that many question whether CABG is still has a role in primary revascularisation. The consequence for SR is that currently it is increasingly likely to be in response to in-stent restenosis, whereby previously it was performed in those with prior CABG. The recent SYNTAX trial has reaffirmed the position of CABG in the treatment of those with complex coronary disease. Consequently we believe that matters have turned a full circle, and expect that SR in the future is most likely to be in form of PCI on patients 8-15 years post primary CABG.
Combined Open and Endovascular Repair for Aortic Arch Pathology
Kang, Woong Chol; Ahn, Tae Hoon; Lee, Kyung Hoon; Moon, Chan Il; Han, Seung Hwan; Park, Chul-Hyun; Park, Kook-Yang; Kang, Jin Mo; Kim, Jung Ho
2010-01-01
Background and Objectives We describe our experience with combined open and endovascular repair in patients who have aortic arch pathology. Subjects and Methods This study is a retrospective analysis of 7 patients who underwent combined open and endovascular repair for aortic arch pathology. Medical records and radiographic information were reviewed. Results A total of 7 consecutive patients (5 men, 71.4%) underwent thoracic stent graft implantation. The mean age was 59.9±16.7 years. The indication for endovascular repair was aneurysmal degeneration in 5 patients, and rupture or impending rupture in 2 patients. In all 7 cases, supra-aortic transposition of the great vessels was performed successfully. Stent graft implantation was achieved in all cases. Surgical exposure of the access vessel was necessary in 2 patients. A total of 9 stent grafts were implanted (3 stent grafts in one patient). The Seal thoracic and the Valiant endovascular stent graft were implanted in 6 patients and 1 patient, respectively. There were no post-procedure deaths or neurologic complications. In 2 patients, bleeding and injury of access vessel were noted after the procedure. Postoperative endoleak was noted in 1 patient. One patient died at 10 months after the procedure due to a newly developed ascending aortic dissection. No patients required secondary intervention during the follow-up period. The aortic diameter decreased in 4 patients. In 3 patients, including 1 patient with endoleak, there was no change in aortic diameter. Conclusion Our experience suggests that combined open and endovascular repair for aortic arch pathology is safe and effective, with few complications. PMID:20830254
Clinical experience in coronary stenting with the Vivant Z Stent.
Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H
2005-06-01
This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
Improvement in conformability of the latest generation of thoracic stent grafts.
Canaud, Ludovic; Cathala, Philipe; Joyeux, Frédéric; Branchereau, Pascal; Marty-Ané, Charles; Alric, Pierre
2013-04-01
Poor aortic arch apposition increases the risk of technical failure after thoracic endovascular repair. The aim of this study was to assess the conformability of the latest generation of thoracic stent grafts in relation to the degree of device oversizing and aortic arch angulation. A benchtop pulsatile flow model was designed to test stent graft anchorage in a 2-cm-long proximal landing zone at varying landing zone angles (from 140° down to 70°) and stent graft oversizing (12%-28%). The experiments were performed using 10 human thoracic cadaveric aortas and four stent grafts: C-TAG, Zenith TX2 Pro-Form, Valiant Captivia, and Relay. Device-wall apposition was measured as a function of landing zone angulation and oversizing during static and dynamic (60 pulses/min, 300/150 mm Hg) tests. The Valiant stent graft remained apposed to the aortic wall at each increment of neck angulation and device oversizing. Lack of apposition of the proximal anchorage segment was observed with the C-TAG above 120° landing zone angulation (1-2 mm) and with the Relay above 110° landing zone angulation (1-4 mm). Lack of "body" apposition (1-4 mm) was first observed with the Zenith Pro-Form stent graft above 110° angulation (P = .001). When the device was not apposed to the aortic wall, an increase in stent graft oversizing significantly (P = .01) decreased device-wall apposition. The requirement for close conformability has influenced the design of next-generation devices. Manufacturers have modified devices and/or their deployment system to specifically address this problem. When compared with the results of our previous experimental test, this study demonstrates that these alterations have resulted in a marked improvement in the performance of commercially available stent graft systems. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Wolfschmidt, Franziska; Hassold, Nicole; Goltz, Jan Peter; Leyh, Rainer; Bley, Thorsten Alexander; Kickuth, Ralph
2015-09-01
To evaluate the feasibility, effectiveness, and safety of using a commercially available reentry catheter with fluoroscopic guidance to gain controlled target lumen reentry for fenestration in patients with aortic dissection. This retrospective study was approved by the local institutional review board; informed consent was waived. Between April 2009 and December 2013, 13 consecutive patients (10 men and three women; mean age, 51.2 years; range, 30.0-77.0 years; mean age of women, 47.0 years; range, 30.0-69.0 years; mean age of men, 52.4 years; range, 35.0-77.0 years) with aortic dissection and spinal (n = 4), renal (n = 7), mesenteric (n = 2), and/or iliofemoral (n = 9) malperfusion syndrome were included. All patients received target lumen reentry by means of balloon fenestration of the aortic dissection flap. A reentry catheter was used for fluoroscopically guided puncture of the target lumen. Technical success, clinical outcome, Stanford type of dissection, procedure time, number of fenestrations of the intimal flap per patient, necessity of additional aortic stent-graft implantation and/or placement of a bare metal stent, complications, and follow-up images were evaluated. Pre- and postinterventional systolic blood pressure gradients between the true lumen and the false lumen were compared (Wilcoxon signed-rank test). Safety of the reentry catheter maneuver was estimated with the Clopper-Pearson method. Use of the reentry catheter was technically successful in all 13 (100%) patients and clinically successful in 10 of 13 (77%) patients. Four patients had type A and nine had type B dissection. The mean clinical follow-up period was 14.2 months. Median procedure time was 71 minutes. In four patients, fenestration of the intimal flap was performed twice. Three patients underwent additional aortic stent grafting, four patients underwent placement of an iliofemoral stent, and one patient underwent placement of a carotid artery stent. Blood pressure gradients between the true lumen and the false lumen were significantly reduced (P = .0313). One patient who had a combination of syndromes died of multiorgan failure. The applied commercially available reentry catheter seems to be a reliable and safe tool that may be useful for gaining target lumen reentry with reasonably good clinical outcomes.
Esfahanian, Vahid; Farhad, Shirin; Sadighi Shamami, Mehrnaz
2014-01-01
Background and aims. Furcally-involved teeth present unique challenges to the success of periodontal therapy and influence treatment outcomes. This study aimed to assess to compare use of ADM and connective tissue membrane in class II furcation defect regeneration. Materials and methods. 10 patient with 2 bilaterally class II furcation defects in first and/or second maxilla or man-dibular molar without interproximal furcation involvement, were selected. Four weeks after initial phase of treatment, before and thorough the surgery pocket depth (PD), clinical attachment level to stent (CAL-S), free gingival margin to stent(FGM-S) , crestal bone to stent (Crest-S), horizontal defect depth to stent (HDD-S) and vertical defect depth to stent (VDD-S) and crestal bone to defect depth measured from stent margin. Thereafter, one side randomly treated using connective tissue and DFDBA (study group) and opposite side received ADM and DFDBA (control group). After 6 months, soft and hard tissue parameters measured again in re-entry. Results. Both groups presented improvements after therapies (P & 0.05). No inter-group differences were seen in PD re-duction (P = 0.275), CAL gain (P = 0.156), free gingival margin (P = 0.146), crest of the bone (P = 0.248), reduction in horizontal defects depth (P = 0.139) and reduction in vertical defects depth (P = 0.149). Conclusion. Both treatments modalities have potential of regeneration without any adverse effect on healing process. Connective tissue grafts did not have significant higher bone fill compared to that of ADM. PMID:25093054
Ceresoli, Marco; Fugazzola, Paola; Ansaloni, Luca
2017-01-01
Introduction Emergency resection represents the traditional treatment for left-sided malignant obstruction. However, the placement of self-expanding metallic stents and delayed surgery has been proposed as an alternative approach. The aim of the current meta-analysis was to review the available evidence, with particular interest for the short-term outcomes, including a recent multicentre RCT. Methods We considered randomized controlled trials comparing stenting as a bridge to surgery and emergency surgery for the management of left-sided malignant large bowel obstruction, performing a systematic review in MEDLINE, PubMed database, and the Cochrane libraries. Results We initially identified a total of 2543 studies. After the elimination of duplicates and the screening of titles and abstracts, seven studies, for a total of 448 patients, were considered. The current meta-analysis revealed no difference in the mortality rate between the stent group and the emergency surgery group; the postoperative complication rate (37.84% versus 54.87%, P = 0.02), the stoma rate (28.8% versus 46.02%, P < 0.0001), and the incidence of wound infection (8.11% versus 15.49%, P = 0.01) were reduced after stent as a bridge to surgery. Conclusion Colonic stenting as a bridge to surgery appears to be a safe approach to malignant large bowel obstruction. Possible advantages of this treatment can be identified in a reduced incidence of postoperative complications and a lower stoma rate. Further RCTs considering long-term outcomes and cost-effectiveness analysis are needed. PMID:28761765
Cannon, Robert M.; Brown, Russell E.; Ellis, Susan F.; Williams, Sharon; Scoggins, C.R.; Abbas, Abbas E.
2014-01-01
Purpose. To determine whether self-expanding plastic stent (SEPS) placement significantly improves quality of life and maintains optimal nutrition while allowing full-dose neoadjuvant therapy (NAT) in patients with esophageal cancer. Patients and Methods. A prospective, dual-institution, single-arm, phase II (http://ClinicalTrials.gov: NCT00727376) evaluation of esophageal cancer patients undergoing NAT prior to resection. All patients had a self-expanding polymer stent placed prior to NAT. The European Organisation for Research and Treatment of Cancer QLQ-C30 and QLQ-OG25, Functional Assessment of Cancer Therapy–Anorexia, and Functional Assessment of Cancer Therapy–General surveys were administered prior to stenting, within 1 week post-stent placement, and at the completion of neoadjuvant therapy. Results. Fifty-two patients were enrolled; 3 (5.8%) had stent migrations requiring replacement. There were no instances of esophageal erosion or perforation. All patients received some form of neoadjuvant therapy. Thirty-six (69%) received chemoradiation; 34 (93%) of these patients received the planned dose of chemotherapy, and 27 (75%) received the full planned dose of radiotherapy. There were 16 (31%) patients receiving chemotherapy alone; 12 (74%) of patients in the chemotherapy-alone group completed the planned dose of therapy. Conclusion. Placement of SEPS appears to provide significant improvement in quality of life related to dysphagia and eating restriction in patients with esophageal cancer undergoing neoadjuvant therapy. Consideration of SEPS instead of percutaneous feeding tube should be initiated as a first line in dysphagia palliation and NAT nutritional support. PMID:24567281
Long-term complications of JJ stent and its management: A 5 years review
Ray, Rajendra Prasad; Mahapatra, Rajkumar Singha; Mondal, Partha Pratim; Pal, Dilip Kumar
2015-01-01
Objectives: To assess the long term complications of JJ stent, the management of complications and the role of endoscopic approach to manage these complications. Materials and Methods: Nineteen patients with indwelling JJ stent for a duration of more than 6 months were included in this study. Patients were assessed with X-ray KUB, USG KUB, blood urea, creatinine and DTPA renogram. Data were analyzed by Microsoft excel 2007. Results: Out of 19 patients 12 (63.16%) were male and 7 (36.84%) were female. The mean age was 39.78 ± 13.69 years., Mean duration for which the stent was in situ was 29.56 months. The most common complication was broken stent, in 11 cases (57.89%). Other complications were migration in 5 (26.32%), encrustation in 2 (10.52%) and 1 case of (5.26%) stone formation. Eighteen cases were managed by endoscopic approaches. A total of 22 procedures were performed to treat the complications. Eleven cases were managed by a single procedure and 8 patients required multiple procedures. All were managed successfully with no death reported. Post-operative complications were seen in eight cases (42.11%). Conclusions: JJ stent related long-term complications are not uncommon and are usually seen after 6 months of indwelling time. Endourological procedure should be the initial approach with a high success rate. Coordinated use multimodality and technology helps in management of difficult cases. Open surgery is rarely required. Prevention of the complication by judicious use and early removal is the cornerstone. PMID:25657542
Endoscopic treatment of malignant airway obstructions in 2,008 patients.
Cavaliere, S; Venuta, F; Foccoli, P; Toninelli, C; La Face, B
1996-12-01
We report our 13-year experience with endoscopic treatment of malignant obstructions of the airway by Nd:YAG laser, stents, and intraluminal brachytherapy in 2,008 patients. We performed 2,610 laser resections in 1,838 patients, 66 high dose rate brachytherapies, and we placed 393 tracheobronchial silicone stents in 306 patients. We used the rigid bronchoscope in 96% of the laser procedures and in all cases requiring stent placement; general anesthesia was given to 90% of these patients. Endobronchial radiotherapy was performed under local, anesthesia. In 93% of patients undergoing laser resection, we obtained an immediate patency of the airway with consequent improvement of quality of life. The median time between the first and second laser treatment was 102 days, being longer in the case of stent placement (when required) or in association with brachytherapy. Even if endoscopic treatment should be considered only for palliation, laser vaporization could be curative in case of in situ carcinoma. Since 1983, we have treated 23 such lesions in 17 patients and up to now, none has recurred. Finally, endoscopic resection may allow a better assessment of the true extent of the tumor, shifting to surgery patients originally considered to have inoperable disease or allowing lung-sparing operations (21 and 18 patients of our series, respectively). The total mortality rate was 0.4% (12 patients over 2,798 treatments; 2,710 Nd:YAG laser + 151 stents without laser + 37 brachytherapies without laser) in the first week after the procedures, and was mainly related to cardiovascular problems and respiratory failure. In conclusion, endoscopic resection of lung malignancies is rapid, effective, repeatable, and complementary to other treatments; although it should be considered only palliative, laser resection could be curative in patients with in situ carcinomas and early cancers. Laser, stents, and endoluminal brachytherapy should be available in all centers with major experience; a well-trained team is mandatory to plan the most appropriate treatment and manage any possible complication.
Flow-induced corrosion behavior of absorbable magnesium-based stents.
Wang, Juan; Giridharan, Venkataraman; Shanov, Vesselin; Xu, Zhigang; Collins, Boyce; White, Leon; Jang, Yongseok; Sankar, Jagannathan; Huang, Nan; Yun, Yeoheung
2014-12-01
The aim of this work was to study corrosion behavior of magnesium (Mg) alloys (MgZnCa plates and AZ31 stents) under varied fluid flow conditions representative of the vascular environment. Experiments revealed that fluid hydrodynamics, fluid flow velocity and shear stress play essential roles in the corrosion behavior of absorbable magnesium-based stent devices. Flow-induced shear stress (FISS) accelerates the overall corrosion (including localized, uniform, pitting and erosion corrosions) due to the increased mass transfer and mechanical force. FISS increased the average uniform corrosion rate, the localized corrosion coverage ratios and depths and the removal rate of corrosion products inside the corrosion pits. For MgZnCa plates, an increase of FISS results in an increased pitting factor but saturates at an FISS of ∼0.15Pa. For AZ31 stents, the volume loss ratio (31%) at 0.056Pa was nearly twice that (17%) at 0Pa before and after corrosion. Flow direction has a significant impact on corrosion behavior as more severe pitting and erosion corrosion was observed on the back ends of the MgZnCa plates, and the corrosion product layer facing the flow direction peeled off from the AZ31 stent struts. This study demonstrates that flow-induced corrosion needs be understood so that Mg-based stents in vascular environments can be effectively designed. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Temporary endoscopic metallic stent for idiopathic esophageal achalasia.
Coppola, Franco; Gaia, Silvia; Rolle, Emanuela; Recchia, Serafino
2014-02-01
Idiopathic achalasia is a motor disorder of the esophagus of unknown etiology caused by loss of motor neurons determining an altered motility. It may determine severe symptoms such as progressive dysphagia, regurgitations, and pulmonary aspirations. Many therapeutic options may be offered to patients with achalasia, from surgery to endoscopic treatments such as pneumatic dilation, botulinum injection, peroral endoscopic myotomy, or endoscopic stenting. Recently, temporary placement of a stent was proposed by Cheng as therapy for achalasia disorders, whereas no Western authors have dealt with it up to date. The present study reports our preliminary experience in 7 patients with achalasia treated with a temporary stent. Partially covered self-expanding metallic stents (Micro-Tech, Nanjin, China) 80 mm long and 30 mm wide were placed under fluoroscopic control and removed after 6 days. Clinical follow-up was scheduled to check endoscopic success, symptoms release, and complications. The placement and the removal of the stents were obtained in all patients without complications. Mean clinical follow-up was 19 months. Five out of 7 patients referred total symptoms release and 2 experienced significant improvement of dysphagia. The procedure was not time consuming and was safe; no mild or severe complications were registered. In conclusion, our results may suggest a possible safe and effective endoscopic alternative treatment in patients with achalasia; however, further larger studies are necessary to confirm these promising, but very preliminary, data.
Durability of renal artery stents in patients with transrenal abdominal aortic endografts.
Baril, Donald T; Lookstein, Robert A; Jacobs, Tikva S; Won, Jamie; Marin, Michael L
2007-05-01
The management of renal artery stenosis in patients with abdominal aortic aneurysms continues to be complex and technically challenging despite advances in endovascular therapy. There is growing concern about the durability of renal artery stents in the setting of transrenal abdominal aortic endografts. This study reports a single-center experience of renal artery stenting with transrenal abdominal aortic endografts for patients with renal artery stenosis. All patients undergoing endovascular abdominal aortic aneurysm repair preceded or followed by renal artery stent placement between January 1999 and December 2005 were retrospectively reviewed from a prospectively gathered endovascular database. Patients were surveyed after renal stent procedures with multidetector computed tomography angiography or duplex sonography. The surveillance data were analyzed for primary patency of the renal artery stent at 6 months, incidence of complications, need for secondary interventions, and changes in creatinine clearance (CrCl). Sixty-two renal artery stents were placed in 56 patients (44 men, 12 women) with a mean age of 77.3 years (range, 61 to 94 years). Forty-one were placed before the endograft procedure, eight were placed during the endograft procedure, and 13 were placed postoperatively. There were no major or minor complications related to the renal artery stent procedures. Transrenal aortic endografts were used in 44 of the 56 patients, and 12 had devices with infrarenal fixation. The mean follow-up was 18.5 months (range, 1 to 73 months). The 6-month primary patency, which could be evaluated for 51 renal artery stents, was 97.4% (37/38) in patients with transrenal fixation and 84.6% (11/13) in patients with infrarenal fixation. The overall rate of in-stent restenosis was 8.5% (4/47) in the transrenal fixation group and 20.0% (3/15) in the infrarenal fixation group. The overall occlusion rate was 2.1% (1/47) in the transrenal fixation group and 0% (0/15) in infrarenal fixation group. Five (83.3%) of six patients underwent successful treatment of in-stent restenosis with placement of a new stent in all five cases. CrCl decreased in the total group by 4.2 +/- 11.8 mL/min, by 4.7 +/- 12.0 mL/min in patients with transrenal fixation, and by 2.2 +/- 11.0 mL/min in patients with infrarenal fixation. The presence of a transrenal aortic endograft did not affect the outcome of the renal artery revascularization procedure in this cohort. Renal artery stenting in the presence of transrenal abdominal aortic endografts appears to be a safe procedure without adverse effect on renal artery stent patency or renal function.
Wu, Gang; Zhao, Yan Shi; Fang, Yi; Qi, Yu; Li, Xiangnan; Jiao, Dechao; Ren, Kewei; Han, Xinwei
2017-01-01
Spontaneous rupture of the esophagus is a rare but life-threatening thoracic emergency, with high rates of clinical misdiagnosis and mortality. This article summarizes our experience in the treatment of spontaneous esophageal rupture with transnasal thoracic drainage and temporary esophageal stent and jejunal feeding tube placement. We retrospectively assessed the medical records of 19 patients with spontaneous esophageal rupture treated using our intervention protocol. Patients received local anesthesia and sedation prior to undergoing transnasal drainage catheter placement into the thoracic abscess cavity, followed by temporary esophageal stent and jejunal feeding tube placement. After the operation, abscess lavage, nutritional support, and anti-inflammatory treatment were given. The transnasal thoracic drainage catheter, esophageal stent, and feeding tube were removed after the healing of the abscess cavity. In all, 19 covered esophageal stents were placed in 19 patients with spontaneous esophageal rupture. All operations were technically successful. After an average of 84.06 days, the stents were successfully removed from 17 patients. No cases of massive hemorrhage, esophageal rupture, or other complications occurred during stent removal. An 82-year-old patient died of heart failure 2 months after the operation. One patient died of sudden massive hematemesis and hematochezia 55 days after the operation. In one patient, the esophageal injury failed to heal completely. Our treatment protocol is simple, minimally invasive, and efficacious and may be an alternative for patients who are not candidates for surgery, have a high risk of postoperative complications, or wish to undergo minimally invasive surgery. Therapeutic study, level V.
Weingertner, A S; Rodriguez, B; Ziane, A; Gibon, E; Thoma, V; Osario, F; Haddad, C; Wattiez, A
2008-08-01
With the increasing number of operative laparoscopies performed for the treatment of deep pelvic endometriosis, technical difficulties and risk of complications inevitably increase. We report our experience using JJ stents, in women treated for deep pelvic endometriosis, with regard to prevention and management of ureteral lesions. Descriptive retrospective analysis between March 2004 and March 2007. Department of Obstetrics and Gynaecology, University Hospital, Strasbourg, France. Cases of women who underwent laparoscopic surgery for severe endometriosis and who needed a JJ stent in their management were recorded. Laparoscopic surgery was performed at the Department of Obstetrics and Gynaecology at CMCO-SIHCUS and Hautepierre Hospitals, Strasbourg, which are referral centres in the treatment of deep endometriosis. To evaluate the contribution of JJ stent in the prevention and management of ureteral lesions from endometriotic origin and/or iatrogenic origin in women treated for deep pelvic endometriosis. A total of 145 women had surgery for deep pelvic endometriosis. Seventeen (11.7%) women had a JJ ureteral stent inserted. In 82.4% of women, the stent was inserted pre- or peroperatively. We noted three ureteral complications, of which only one needed management by laparotomy. Except in extreme cases, management of ureteral endometriosis should be performed laparoscopically. Ureteral lesions whether iatrogenic, or secondary to endometriotic disease, can be treated by cystoscopy, JJ stent and laparoscopy. The combination of these three elements is the optimal management and is unlikely to cause subsequent complications. Laparotomy and its associated morbidity should be avoided.
NASA Astrophysics Data System (ADS)
Poon, Eric; Ooi, Andrew; Barlis, Peter; Hayat, Umair; Moore, Stephen
2014-11-01
Percutaneous coronary intervention (PCI) is the modern gold standard for treatment of coronary artery disease. Stenting (a common PCI procedure) of simple lesion inside a relatively straight segment of coronary artery has proven to be highly successful. However, incomplete stent apposition (ISA) where there is a lack of contact between the stent struts and lumen wall is not uncommon in curved and calcified coronary arteries. Computational fluid dynamics simulations are carried out to study the changes in hemodynamics as a result of ISA inside a curved and calcified coronary artery. For a 3 mm coronary artery, we simulate a resting condition at 80 mL/min and a range of hyperemic conditions with coronary flow reserve in between 1 and 2. The heartbeat is fixed at 75 BPM. Five different curvatures of the coronary artery are considered. Negative effects on hemodynamic variables, such as low wall shear stress (<0.5 Pa); high wall shear stress gradient (>5,000 Pa/m) and oscillation shear index (0 <= OSI <= 0.5), are employed to identify locations with high possibilities of adverse clinical events. This study will lead to better understandings of ISA in curved and calcified coronary arteries and help improve future coronary stent deployment. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).
Stent placement with the monorail technique for treatment of mesenteric artery stenosis.
Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan
2006-04-01
To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.
Koenrades, Maaike A; Klein, Almar; Leferink, Anne M; Slump, Cornelis H; Geelkerken, Robert H
2018-04-01
To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort study (LSPEAS; Trialregister.nl identifier NTR4276). The patients were treated electively using an Anaconda stent-graft with a mean 31% oversizing (range 17-47). According to protocol, participants were to be followed for 2 years, during which 5 noncontrast electrocardiogram-gated computed tomography scans would be conducted. Three patients were eliminated within 30 days (1 withdrew, 1 died, and a third was converted before stent-graft deployment), leaving 15 patients (mean age 72.8±3.7 years; 14 men) for this analysis. Evolution in size and shape (symmetry) of both proximal infrarenal sealing rings were assessed from discharge to 24 months using dedicated postprocessing algorithms. At 24 months, the mean diameters of the first and second ring stents had increased significantly (first ring: 2.2±1.0 mm, p<0.001; second ring: 2.7±1.1 mm, p<0.001). At 6 months, the first and second rings had expanded to a mean 96.6%±2.1% and 94.8%±2.7%, respectively, of their nominal diameter, after which the rings expanded slowly; ring diameters stabilized to near nominal size (first ring, 98.3%±1.1%; second ring, 97.2%±1.4%) at 24 months irrespective of initial oversizing. No type I or III endoleaks or aneurysm-, device-, or procedure-related adverse events were noted in follow-up. The difference in the diametric distances between the peaks and valleys of the saddle-shaped rings was marked at discharge but became smaller after 24 months for both rings (first ring: median 2.0 vs 1.2 mm, p=0.191; second ring: median 2.8 vs 0.8 mm; p=0.013). Irrespective of initial oversizing, the Anaconda proximal sealing rings radially expanded to near nominal size within 6 months after EVAR. Initial oval-shaped rings conformed symmetrically and became nearly circular through 24 months. These findings should be taken into account in planning and follow-up.
[Self-expandable metallic biliary endoprosthesis in malignant obstructive jaundice].
Güitrón-Cantú, Alfredo; Adalid-Martínez, Raúl; Gutiérrez-Bermúdez, José A
2005-01-01
Implantation of metallic stents for malignant biliary strictures has been recognized to be effective alternatives. To show our experience in metallic stents for palliation of malignant biliary strictures. Seventy three patients (38 males, 35 females, mean age 64.26) with malignant biliary strictures have been treated by implantation of metallic stents. Causes of obstruction were pancreatic carcinoma (23/73, 31.5%), bile duct carcinoma (31/73, 42.5%), carcinoma of ampula of Vater (11/73, 15%) and Klatskin tumor (3/73, 4.1%). Endoscopic procedure was successful in all cases. Neither procedure-related morbidity nor mortality was observed. Life surviving curve was 9 months and showed significant difference (p < 0.0071) in patients with carcinoma of ampula of Vater. Self-expanding metal endoprosthesis is a recognized method of palliation in malignant biliary obstruction. It efficiently relieves jaundice and generally improves comfort and nutritional status during the patient's remaining lifetime. The metallic stents are advantageous in patients surviving 6 months or less.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia-Monaco, R. D.; Kohan, A. A., E-mail: andreskohan1@gmail.com; Martinez-Corvalan, M. P.
Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.
2014-01-01
Introduction. Self-expandable metal stents (SEMS) are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%)), with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50%) were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21). Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction. PMID:24526914
Endoscopic Gallbladder Drainage for Acute Cholecystitis
Widmer, Jessica; Alvarez, Paloma; Sharaiha, Reem Z.; Gossain, Sonia; Kedia, Prashant; Sarkaria, Savreet; Sethi, Amrita; Turner, Brian G.; Millman, Jennifer; Lieberman, Michael; Nandakumar, Govind; Umrania, Hiren; Gaidhane, Monica
2015-01-01
Background/Aims Surgery is the mainstay of treatment for cholecystitis. However, gallbladder stenting (GBS) has shown promise in debilitated or high-risk patients. Endoscopic transpapillary GBS and endoscopic ultrasound-guided GBS (EUS-GBS) have been proposed as safe and effective modalities for gallbladder drainage. Methods Data from patients with cholecystitis were prospectively collected from August 2004 to May 2013 from two United States academic university hospitals and analyzed retrospectively. The following treatment algorithm was adopted. Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy and cystic duct stenting was initially attempted. If deemed feasible by the endoscopist, EUS-GBS was then pursued. Results During the study period, 139 patients underwent endoscopic gallbladder drainage. Among these, drainage was performed in 94 and 45 cases for benign and malignant indications, respectively. Successful endoscopic gallbladder drainage was defined as decompression of the gallbladder without incidence of cholecystitis, and was achieved with ERCP and cystic duct stenting in 117 of 128 cases (91%). Successful endoscopic gallbladder drainage was also achieved with EUS-guided gallbladder drainage using transmural stent placement in 11 of 11 cases (100%). Complications occurred in 11 cases (8%). Conclusions Endoscopic gallbladder drainage techniques are safe and efficacious methods for gallbladder decompression in non-surgical patients with comorbidities. PMID:26473125
Endoscopic Management of Pancreatic Fluid Collections in Children.
Nabi, Zaheer; Talukdar, Rupjyoti; Reddy, D Nageshwar
2017-07-15
The incidence of acute pancreatitis in children has increased over the last few decades. The development of pancreatic fluid collection is not uncommon after severe acute pancreatitis, although its natural course in children and adolescents is poorly understood. Asymptomatic fluid collections can be safely observed without any intervention. However, the presence of clinically significant symptoms warrants the drainage of these fluid collections. Endoscopic management of pancreatic fluid collection is safe and effective in adults. The use of endoscopic ultrasound (EUS)-guided procedure has improved the efficacy and safety of drainage of pancreatic fluid collections, which have not been well studied in pediatric populations, barring a scant volume of small case series. Excellent results of EUS-guided drainage in adult patients also need to be verified in children and adolescents. Endoprostheses used to drain pancreatic fluid collections include plastic and metal stents. Metal stents have wider lumens and become clogged less often than plastic stents. Fully covered metal stents specifically designed for pancreatic fluid collection are available, and initial studies have shown encouraging results in adult patients. The future of endoscopic management of pancreatic fluid collection in children appears promising. Prospective studies with larger sample sizes are required to establish their definitive role in the pediatric age group.
Analysis of emboli during carotid stenting with distal protection device.
Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V
2006-01-01
The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p < 0.001). During stenting and angioplasty with the protection device, 7,395 emboli with 42% solids were detected (p < 0.001). Finally injection of contrast after the procedure, with the protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.
Salarifar, Mojtaba; Kassaian, Seyed Ebrahim; Alidoosti, Mohammad; Haji-Zeinali, Ali Mohammad; Poorhoseini, Hamid Reza; Nematipour, Ebrahim; Amirzadegan, Alireza; Saroukhani, Sepideh
2011-01-01
For all the wealth of research comparing the efficacy of the different types of the drug-eluting stent (DES) such as sirolimus-, paclitaxel-, and zotarolimus-eluting stents, there is still a dearth of data on the different brands of each DES type. We aimed to investigate the one-year clinical outcomes, including major adverse cardiac events (MACE), of the use of the ultra long Apollo paclitaxel-eluting stent in patients with long atherosclerotic coronary artery lesions. According to a retrospective review of the Tehran Heart Center Registry of Interventional Cardiology, a single-center nonrandomized computerized data registry in which all adult patients who undergo single or multi-vessel percutaneous coronary intervention (PCI) are enrolled without any specific exclusion criteria, the mixed use of long Apollo paclitaxel-eluting stents and other types of the DES as well as myocardial infarction within forty-eight hours prior to the procedure was excluded. In total, 122 patients were enrolled in the study, and their baseline clinical, angiographic, and procedural characteristics were obtained. In addition, the patients' follow-up data and, most importantly, MACE during a one-year period after intervention were recorded. The mean follow-up duration was 14.1 ± 3.8 months. The one-year clinical follow-up data were obtained in 95.9 % of all the patients. The incidence of MACE was 5.7% during the entire study period. There was 1 death, which occurred during the initial days after PCI. The incidence of non-fatal myocardial infarction was 2.5% (3 cases), including one patient who underwent target vessel revascularization seven months later. Also, 3 patients with single-vessel disease and in-stent restenosis underwent coronary artery bypass grafting between five to ten months later. Our results showed that the Apollo paclitaxel-eluting stent might be regarded as a safe and effective treatment for long coronary lesions.
Bhindi, Ravinay; Kajander, Olli A; Jolly, Sanjit S; Kassam, Saleem; Lavi, Shahar; Niemelä, Kari; Fung, Anthony; Cheema, Asim N; Meeks, Brandi; Alexopoulos, Dimitrios; Kočka, Viktor; Cantor, Warren J; Kaivosoja, Timo P; Shestakovska, Olga; Gao, Peggy; Stankovic, Goran; Džavík, Vladimír; Sheth, Tej
2015-08-01
Manual thrombectomy has been proposed as a strategy to reduce thrombus burden during primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI). However, the effectiveness of manual thrombectomy in reducing thrombus burden is uncertain. In this substudy of the TOTAL (ThrOmbecTomy versus PCI ALone) trial, we compared the thrombus burden at the culprit lesion using optical coherence tomography (OCT) in patients treated with thrombectomy vs. PCI-alone. The TOTAL trial (N = 10 732) was an international, multicentre, randomized trial of thrombectomy (using the Export catheter, Medtronic Cardiovascular, Santa Rosa, CA, USA) in STEMI patients treated with primary PCI. The OCT substudy prospectively enrolled 214 patients from 13 sites in 5 countries. Optical coherence tomography was performed immediately after thrombectomy or PCI-alone and then repeated after stent deployment. Thrombus quantification was performed by an independent core laboratory blinded to treatment assignment. The primary outcome of pre-stent thrombus burden as a percentage of segment analysed was 2.36% (95% CI: 1.73-3.22) in the thrombectomy group and 2.88% (95% CI: 2.12-3.90) in the PCI-alone group (P = 0.373). Absolute pre-stent thrombus volume was not different (2.99 vs. 3.74 mm(3), P = 0.329). Other secondary outcomes of pre-stent quadrants of thrombus, post-stent atherothrombotic burden, and post-stent atherothrombotic volume were not different between groups. Manual thrombectomy did not reduce pre-stent thrombus burden at the culprit lesion compared with PCI-alone. Both strategies were associated with low thrombus burden at the lesion site after the initial intervention to restore flow. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
van Hooft, Jeanin E; Bemelman, Willem A; Breumelhof, Ronald; Siersema, Peter D; Kruyt, Philip M; van der Linde, Klaas; Veenendaal, Roeland A; Verhulst, Marie-Louise; Marinelli, Andreas W; Gerritsen, Josephus JGM; van Berkel, Anne-Marie; Timmer, Robin; Grubben, Marina JAL; Scholten, Pieter; Geraedts, Alfons AM; Oldenburg, Bas; Sprangers, Mirjam AG; Bossuyt, Patrick MM; Fockens, Paul
2007-01-01
Background Acute left-sided colonic obstruction is most often caused by malignancy and the surgical treatment is associated with a high mortality and morbidity rate. Moreover, these operated patients end up with a temporary or permanent stoma. Initial insertion of an enteral stent to decompress the obstructed colon, allowing for surgery to be performed electively, is gaining popularity. In uncontrolled studies stent placement before elective surgery has been suggested to decrease mortality, morbidity and number of colostomies. However stent perforation can lead to peritoneal tumor spill, changing a potentially curable disease in an incurable one. Therefore it is of paramount importance to compare the outcomes of colonic stenting followed by elective surgery with emergency surgery for the management of acute left-sided malignant colonic obstruction in a randomized multicenter fashion. Methods/design Patients with acute left-sided malignant colonic obstruction eligible for this study will be randomized to either emergency surgery (current standard treatment) or colonic stenting as bridge to elective surgery. Outcome measurements are effectiveness and costs of both strategies. Effectiveness will be evaluated in terms of quality of life, morbidity and mortality. Quality of life will be measured with standardized questionnaires (EORTC QLQ-C30, EORTC QLQ-CR38, EQ-5D and EQ-VAS). Morbidity is defined as every event leading to hospital admission or prolonging hospital stay. Mortality will be analyzed as total mortality as well as procedure-related mortality. The total costs of treatment will be evaluated by counting volumes and calculating unit prices. Including 120 patients on a 1:1 basis will have 80% power to detect an effect size of 0.5 on the EORTC QLQ-C30 global health scale, using a two group t-test with a 0.05 two-sided significance level. Differences in quality of life and morbidity will be analyzed using mixed-models repeated measures analysis of variance. Mortality will be compared using Kaplan-Meier curves and log-rank statistics. Discussion The Stent-in 2 study is a randomized controlled multicenter trial that will provide evidence whether or not colonic stenting as bridge to surgery is to be performed in patients with acute left-sided colonic obstruction. Trial registration Current Controlled Trials ISRCTN46462267. PMID:17608947
Tang, Zhe; Bai, Jing; Su, Shao-Ping; Lee, Pui-Wai; Peng, Liang; Zhang, Tao; Sun, Ting; Nong, Jing-Guo; Li, Tian-De; Wang, Yu
2016-01-01
Objective To evaluate the factors affecting optimal stent expansion in calcified lesions treated by aggressive plaque modification with rotational atherectomy (RA) and a cutting balloon (CB). Methods From January 2014 to May 2015, 92 patients with moderate to severe coronary calcified lesions underwent rotational atherectomy and intravascular ultrasound imaging at Chinese PLA General Hospital (Beijing, China) were included in this study. They were divided into a rotational artherectomy combined with cutting balloon (RACB) group (46 patients treated with RA followed by CB angioplasty) and an RA group (46 patients treated with RA followed by plain balloon angioplasty). Another 40 patients with similar severity of their calcified lesions treated with plain old balloon angioplasty (POBA) were demographically matched to the other groups and defined as the POBA group. All patients received a drug-eluting stent after plaque preparation. Lumen diameter and lumen diameter stenosis (LDS) were measured by quantitative coronary angiography at baseline, after RA, after dilatation, and after stenting. Optimal stent expansion was defined as the final LDS < 10%. Results The initial and post-RA LDS values were similar among the three groups. However, after dilatation, the LDS significantly decreased in the RACB group (from 54.5% ± 8.9% to 36.1% ± 7.1%) but only moderately decreased (from 55.7% ± 7.8% to 46.9% ± 9.4%) in the RA group (time × group, P < 0.001). After stenting, there was a higher rate of optimal stent expansion in the RACB group (71.7% in the RACB group, 54.5% in the RA group, and 15% in the POBA group, P < 0.001), and the final LDS was significantly diminished in the RACB group compared to the other two groups (6.0% ± 2.3%, 10.8% ± 3.3%, 12.7% ± 2.1%, P < 0.001). Moreover, an LDS ≤ 40% after plaque preparation (OR = 2.994, 95% CI: 1.297–6.911) was associated with optimal stent expansion, which also had a positive correlation with the appearance of a calcified ring split (r = 0.581, P < 0.001). Conclusions Aggressive plaque modification with RA and CB achieve more optimal stent expansion. An LDS ≤ 40% after plaque modification was a predictive factor for optimal stent expansion in calcified lesions. This parameter was also associated with the presence of calcified ring split. PMID:28321242
Hudson, Joseph S; Prout, Benjamin S; Nagahama, Yasunori; Nakagawa, Daichi; Guerrero, Waldo R; Zanaty, Mario; Chalouhi, Nohra; Jabbour, Pascal; Dandapat, Sudeepta; Allan, Lauren; Ortega-Gutierrez, Santiago; Samaniego, Edgar A; Hasan, David
2018-04-11
Stenting and flow diversion for aneurysmal sub arachnoid hemorrhage (aSAH) require the use of dual antiplatelet therapy (DAPT). To investigate whether DAPT is associated with hemorrhagic complication following placement of external ventricular drains (EVD) in patients with aSAH. Rates of radiographically identified hemorrhage associated with EVD placement were compared between patients who received DAPT for stenting or flow diversion, and patients who underwent microsurgical clipping or coiling and did not receive DAPT by way of a backward stepwise multivariate analysis. Four hundred forty-three patients were admitted for aSAH management. Two hundred ninety-eight patients required placement of an EVD. One hundred twenty patients (40%) were treated with stent-assisted coiling or flow diversion and required DAPT, while 178 patients (60%) were treated with coiling without stents or microsurgical clipping and did not receive DAPT. Forty-two (14%) cases of new hemorrhage along the EVD catheter were identified radiographically. Thirty-two of these hemorrhages occurred in patients on DAPT, while 10 occurred in patients without DAPT. After multivariate analysis, DAPT was significantly associated with radiographic hemorrhage [odds ratio: 4.92, 95% confidence interval: 2.45-9.91, P = .0001]. We did not observe an increased proportion of symptomatic hemorrhage in patients receiving DAPT (10 of 32 [31%]) vs those without (5 of 10 [50%]; P = .4508). Patients with aSAH who receive stent-assisted coiling or flow diversion are at higher risk for radiographic hemorrhage associated with EVD placement. The timing between EVD placement and DAPT initiation does not appear to be of clinical significance. Stenting and flow diversion remain viable options for aSAH patients.
Rodriguez, Alfredo E; Palacios, Igor; Rodriguez-Granillo, Alfredo M; Mieres, Juan R; Tarragona, Sonia; Fernandez-Pereira, Carlos; Solorzano, Leonardo; Pauletto, Ricardo; Serruys, Patrick W; Antoniucci, David
2014-03-01
The aim of this study was to compare 5-year cost-effectiveness and clinical outcomes of patients with oral rapamycin (OR) plus bare-metal stent versus the drug-eluting stent (DES) strategy. During 2006 to 2007, a total of 200 patients were randomized to OR (n = 100) and DES (n = 100). Primary end point was to compare costs of initial procedure and cost-effectiveness of both revascularization strategies. Safety was evaluated by the composite of death, myocardial infarction, and cerebrovascular accident. Efficacy was assessed by target vessel and target lesion revascularizations. The 2 groups had similar baseline demographic, clinical, and angiographic characteristics. In the DES group, paclitaxel-, zotarolimus-, and sirolimus-eluting stents were used. Five-year clinical follow-up was accomplished in 99% patients. The DES group had significantly higher procedural (p <0.001), discharge to first-year (p = 0.02), and 1- to 5-year costs (p <0.001) compared with the OR group. At 5 years, the composite end point of death, myocardial infarction, and cerebrovascular accident (12% in the OR group vs 25% in the DES group, p = 0.01) was significantly less in the OR group. Target vessel revascularization (14.5% in the OR group vs 21% in the DES group, p = 0.16) and target lesion revascularization (10% in the OR group vs 17.6% in the DES group, p = 0.05) were not significantly different. In conclusion, a strategy of OR plus bare-metal stent was cost saving than a first-generation DES. Copyright © 2014 Elsevier Inc. All rights reserved.
Lesion complexity drives the cost of superficial femoral artery endovascular interventions
Walker, Karen L.; Nolan, Brian W.; Columbo, Jesse A.; Rzucidlo, Eva M.; Goodney, Philip P.; Walsh, Daniel B.; Atkinson, Benjamin J.; Powell, Richard J.
2017-01-01
Objective Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. Methods A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. Results During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. Conclusions SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. PMID:26206581
Lesion complexity drives the cost of superficial femoral artery endovascular interventions.
Walker, Karen L; Nolan, Brian W; Columbo, Jesse A; Rzucidlo, Eva M; Goodney, Philip P; Walsh, Daniel B; Atkinson, Benjamin J; Powell, Richard J
2015-10-01
Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Percutaneous Treatment of Central Venous Stenosis in Hemodialysis Patients: Long-Term Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Chul; Won, Jong Yun, E-mail: jywon@yumc.yonsei.ac.kr; Choi, Sun Young
2009-03-15
The purpose of this study was to evaluate the long-term outcomes of endovascular treatment of central venous stenosis in patients with arteriovenous fistulas (AVFs) for hemodialysis. Five hundred sixty-three patients with AVFs who were referred for a fistulogram were enrolled in this study. Among them, 44 patients showed stenosis (n = 35) or occlusions (n = 9) in the central vein. For the initial treatment, 26 patients underwent percutaneous transluminal angioplasty (PTA) and 15 patients underwent stent placements. Periods between AVF formation and first intervention ranged from 3 to 144 months. Each patient was followed for 14 to 60 months.more » Procedures were successful in 41 of 44 patients (93.2%). Primary patency rates for PTA at 12 and 36 months were 52.1% and 20.0%, and assisted primary patency rates were 77.8% and 33.3%, respectively. Primary patency rates for stent at 12 and 36 months were 46.7% and 6.7%, and assisted primary patency rates were 60.0% and 20.0%, respectively. Fifteen of 26 patients with PTAs underwent repeated interventions because of restenosis. Fourteen of 15 patients with a stent underwent repeated interventions because of restenosis and combined migration (n = 1) and shortening (n = 6) of the first stent. There was no significant difference in patency between PTAs and stent placement (p > 0.05). Average AVF patency duration was 61.8 months and average number of endovascular treatments was 2.12. In conclusion, endovascular treatments of central venous stenosis could lengthen the available period of AVFs. There was no significant difference in patency between PTAs and stent placement.« less
Kim, Jihye; Min, Yang Won; Lee, Hyuk; Min, Byung Hoon; Lee, Joon Haeng; Rhee, Poong Lyul; Kim, Jae J
2018-03-25
Dysphagia is encountered in a large proportion of patients with lung cancer and is associated with malnutrition and a poor quality of life. This study compared the clinical outcomes of self-expandable metallic stent (SEMS) insertion and percutaneous gastrostomy (PG) feeding for patients with lung cancer and dysphagia. A total of 261 patients with lung cancer, who underwent either SEMS insertion (stent group) or PG (gastrostomy group) as an initial treatment procedure for dysphagia between July 1997 and July 2015 at the Samsung Medical Center, were reviewed retrospectively, and 84 patients with esophageal obstruction were identified. The clinical outcomes, including the overall survival, additional intervention, complications, and post-procedural nutritional status in the two groups, were compared. Among the 84 patients finally analyzed, 68 patients received SEMS insertion and 16 had PG. The stent group had less cervical obstruction and more mid-esophageal obstruction than the gastrostomy group. The Kaplan-Meier curves revealed similar overall survival in the two groups. Multivariate analysis showed that the two modalities had similar survival rates (PG compared with SEMS insertion, hazard ratio 0.682, p=0.219). Fifteen patients (22.1%) in the stent group received additional intervention, whereas there was no case in the gastrostomy group (p=0.063). The decrease in the serum albumin level after the procedure was lower in the gastrostomy group than in the stent group (-0.20±0.54 g/dL vs. -0.65±0.57 g/dL, p=0.013). SEMS insertion and PG feeding for relieving dysphagia by lung cancer had a comparable survival outcome. On the other hand, PG was associated with a better nutritional status.
My Interventional Drug-Eluting Stent Educational App (MyIDEA): Patient-Centered Design Methodology
Shroff, Adhir; Groo, Vicki; Dickens, Carolyn; Field, Jerry; Baumann, Matthew; Welland, Betty; Gutowski, Gerry; Flores Jr, Jose D; Zhao, Zhongsheng; Bahroos, Neil; Hynes, Denise M; Wilkie, Diana J
2015-01-01
Background Patient adherence to medication regimens is critical in most chronic disease treatment plans. This study uses a patient-centered tablet app, “My Interventional Drug-Eluting Stent Educational App (MyIDEA).” This is an educational program designed to improve patient medication adherence. Objective Our goal is to describe the design, methodology, limitations, and results of the MyIDEA tablet app. We created a mobile technology-based patient education app to improve dual antiplatelet therapy adherence in patients who underwent a percutaneous coronary intervention and received a drug-eluting stent. Methods Patient advisers were involved in the development process of MyIDEA from the initial wireframe to the final launch of the product. The program was restructured and redesigned based on the patient advisers’ suggestions as well as those from multidisciplinary team members. To accommodate those with low health literacy, we modified the language and employed attractive color schemes to improve ease of use. We assumed that the target patient population may have little to no experience with electronic tablets, and therefore, we designed the interface to be as intuitive as possible. Results The MyIDEA app has been successfully deployed to a low-health-literate elderly patient population in the hospital setting. A total of 6 patients have interacted with MyIDEA for an average of 17.6 minutes/session. Conclusions Including patient advisers in the early phases of a mobile patient education development process is critical. A number of changes in text order, language, and color schemes occurred to improve ease of use. The MyIDEA program has been successfully deployed to a low-health-literate elderly patient population. Leveraging patient advisers throughout the development process helps to ensure implementation success. PMID:26139587
Mosquera Arochena, N; Rodríguez Feijoo, G; Carballo Fernandez, C; Molina Herrero, F; Fernandez Lebrato, R; Barrios Castro, A; Garcia Fernandez, I
2011-10-01
Since the introduction of the first endoprosthetic devices, continuous development in techniques and implants has occurred, such as the introduction of a stent graft with branches designed to preserve antegrade flow in the hypogastric artery, a stent-graft designed to treat extreme neck angulation and iliac tortuosity, as well as "Sandwich" and "Chimney" techniques used to maintain perfusion in branch vessels originating in the region to be treated. This paper describes how the Sandwich-Graft technique was adapted, as described by Lobato et al., employing the Aorfix™ system (Lombard Medical) and the Viabahn™ (W.L.Gore) to preserve hypogastric flow in cases with extreme neck angulation and iliac tortuosity. The study included four patients treated from April 2010 until November 2010 with the modified Sandwich technique. All patients eligible for this approach were considered unfit for open repair and were not suitable for an iliac branch graft (Z-BIS Zenith™ Cook Medical). A bifurcated endograft was implanted with specific, in-situ, branching to the target hypogastric artery and achieved clinical and technical success, in all the patients. After a 11-month follow-up in two cases and a six-month follow-up in the other two, clinical results were successful. All patients were endoleak-free, had patent hypogastric branches and had shrinking or stable aneurysms. The initial experience shows that the Sandwich technique with the Aorfix™ stent-graft demonstrated to be effective in endovascular repair of abdominal aortic aneurysms in patients with aortoiliac anatomy hostile to preserving hypogastric artery patency. This graft allows a broader group of patients to be treated with endovascular repair without potential complications of hypogastric artery occlusion; however, further studies are needed to evaluate long-term results in larger numbers of patients.
Dijkstra, Martijn L; Tielliu, Ignace F J; Meerwaldt, Robbert; Pierie, Maurice; van Brussel, Jerome; Schurink, Geert Willem H; Lardenoye, Jan-Willem; Zeebregts, Clark J
2014-08-01
In the past decennium, the management of short-neck infrarenal and juxtarenal aortic aneurysms with fenestrated endovascular aneurysm repair (FEVAR) has been shown to be successful, with good early and midterm results. Recently, a new fenestrated device, the fenestrated Anaconda (Vascutek, Renfrewshire, Scotland), was introduced. The aim of this study was to present the current Dutch experience with this device. A prospectively held database of patients treated with the fenestrated Anaconda endograft was analyzed. Decision to treat was based on current international guidelines. Indications for FEVAR included an abdominal aortic aneurysm (AAA) with unsuitable neck anatomy for EVAR. Planning was performed on computed tomography angiography images using a three-dimensional workstation. Between May 2011 and September 2013, 25 patients were treated in eight institutions for juxtarenal (n = 23) and short-neck AAA (n = 2). Median AAA size was 61 mm (59-68.5 mm). All procedures except one were performed with bifurcated devices. A total of 56 fenestrations were incorporated, and 53 (94.6%) were successfully cannulated and stented. One patient died of bowel ischemia caused by occlusion of the superior mesenteric artery. On completion angiography, three type I endoleaks and seven type II endoleaks were observed. At 1 month of follow-up, all endoleaks had spontaneously resolved. Median follow-up was 11 months (range, 1-29 months). There were no aneurysm ruptures or aneurysm-related deaths and no reinterventions to date. Primary patency at 1 month of cannulated and stented target vessels was 96%. Initial and short-term results of FEVAR using the fenestrated Anaconda endograft are promising, with acceptable technical success and short-term complication rates. Growing experience and long-term results are needed to support these findings. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Pedersen, Susanne S; Lemos, Pedro A; van Vooren, Priya R; Liu, Tommy K K; Daemen, Joost; Erdman, Ruud A M; Smits, Pieter C; Serruys, Patrick W J C; van Domburg, Ron T
2004-09-01
We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative emotions and tend not to express these emotions in social interactions. The SES is a new advent in interventional cardiology that reduces the restenosis rate and the risk of a major adverse cardiac event, but the SES has not been shown to confer any benefits on death or myocardial infarction (MI). Consecutive patients with IHD (n = 875) enrolled in the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry completed the Type D Personality Scale (DS14) six months after PCI. The end point was a composite of death and MI. Events occurring before administration of the DS14 were excluded from analyses. At nine months' follow-up, there were 20 events. Type D patients were at a cumulative increased risk of adverse outcome compared with non-Type D patients: 5.6% versus 1.3% (p < 0.002). Type D personality (odds ratio [OR] 5.31; 95% confidence interval [CI] 2.06 to 13.66) remained an independent predictor of adverse outcome adjusting for all other variables, including SES versus bare-stent implantation. Type D personality was an independent predictor of adverse events in patients optimally treated with the latest advent in interventional cardiology. The DS14 could be used as a screening instrument in routine clinical practice to optimize risk stratification in IHD patients.
Brountzos, E N; Petersen, B; Binkert, C; Panagiotou, I; Kaufman, J A
2004-01-01
To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions.
The consequence of premature silicone stent loss after external dacryocystorhinostomy.
Vicinanzo, Matthew G; McGwin, Gerald; Boyle, Michael; Long, John A
2008-07-01
To investigate the clinical affects of premature silicone stent loss after external dacryocystorhinostomy (DCR). Retrospective chart review. Two hundred thirty-three consecutive external dacryocystorhinostomies. Demographic information was recorded, including length to follow-up, age, gender, number of days until stent removal, and success of surgery. All patients who extruded their silicone stent prematurely were identified. All were primary DCRs (i.e., all reoperations were excluded). All patients had had documented nasolacrimal duct obstruction before surgery, with or without current or prior dacryocystitis. Failure of DCR surgery was accepted as symptomatic epiphora with notable nasolacrimal duct blockage and/or infection at long term follow-up. Of the 233 DCRs, 42 stents extruded or had to be removed before the planned 2-month period. The overall success rate of the surgery was 94.9%, with a 90.5% success for those who had early extrusion and 95.8% for those who did not (P = 0.24). Moreover, of the 4 people who had a failed surgery (of 42 early extrusions), none had a recurrent infection or pain, and only 1 opted to have a revision of the surgery. Patient age, gender, or timing of the extrusion was not found to affect surgical success significantly. Our experience and this study suggest that concerns over early stent extrusion or removal may not be wholly warranted. Moreover, our review of the literature shows no evidence-based recommendations that longer stent retention or reintubation after early extrusion results in a higher success rate. Although other surgeries (e.g., canalicular laceration, congenital epiphora) may benefit from intervention or reinsertion after early extrusion, we cannot extrapolate such a practice for the DCR.
Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi
2017-12-08
This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.
Anile, M; Venuta, F; Diso, D; Liparulo, V; Ricella, C; De Giacomo, T; Pugliese, F; Rolla, M; Quattrucci, S; Pecoraro, Y; Rendina, E A; Coloni, G F
2010-05-01
Airway complications (AC) are considered a serious cause of morbidity after lung transplantation (LT). Mechanical dilatation, laser vaporization, and silicone stent placement usually solve it. However, the use of self-expandable metallic stents (SENS) may be indicated in selected cases. Ten lung transplant recipients with AC were treated with SENS. Six patients underwent LT for cystic fibrosis, 2 for idiopathic pulmonary fibrosis, 1 for bronchiectasis, and 1 for emphysema. All patients received at least 1 treatment attempt with dilatation and silicone stent placement. The indications for SENS placement were the presence of a tortuous airway axis with stenosis and malacia of the right main bronchus in 5 patients; a long stenosis of the main and intermediate right bronchus involving the upper lobe orifice in 3 patients; or malacia that could not be stabilized with silicone stents in 3 cases. In 1 patient the procedure was bilateral. Functional improvement was immediate with a mean forced expiratory volume at 1 second (FEV(1)) gain of 35%. No stent dislocation was observed. Symptoms did not occur again in 5 patients with previous recurrent episodes of pneumonia. One stenosis, which was due to the ingrowth of granulation tissue occurred at 6 months after the procedure, was successfully treated with mechanical dilatation and laser vaporization. The deployment of SENS in a selected group of patients with AC after LT was easy, safe, and effective. Copyright (c) 2010 Elsevier Inc. All rights reserved.
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive 125I Seeds
Yao, Li-Hong; Wang, Jun-Jie; Shang, Charles; Jiang, Ping; Lin, Lei; Sun, Hai-Tao; Liu, Lu; Liu, Hao; He, Di; Yang, Rui-Jie
2017-01-01
Background: A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths — with different number as well as activities of 125I seeds. Methods: The radiation dosimetry of three representative radioactive stent models was evaluated using a treatment planning system (TPS), thermoluminescent dosimeter (TLD) measurements, and Monte Carlo (MC) simulations. In the process of TPS calculation and TLD measurement, two different water-equivalent phantoms were designed to obtain cumulative radial dose distribution. Calibration procedures using TLD in the designed phantom were also conducted. MC simulations were performed using the Monte Carlo N-Particle eXtended version 2.5 general purpose code to calculate the radioactive stent's three-dimensional dose rate distribution in liquid water. Analysis of covariance was used to examine the factors influencing radial dose distribution of the radioactive stent. Results: The maximum reduction in cumulative radial dose was 26% when the seed activity changed from 0.5 mCi to 0.4 mCi for the same length of radioactive stents. The TLD's dose response in the range of 0–10 mGy irradiation by 137Cs γ-ray was linear: y = 182225x − 6651.9 (R2= 0.99152; y is the irradiation dose in mGy, x is the TLDs’ reading in nC). When TLDs were irradiated by different energy radiation sources to a dose of 1 mGy, reading of TLDs was different. Doses at a distance of 0.1 cm from the three stents’ surface simulated by MC were 79, 93, and 97 Gy. Conclusions: TPS calculation, TLD measurement, and MC simulation were performed and were found to be in good agreement. Although the whole experiment was conducted in water-equivalent phantom, data in our evaluation may provide a theoretical basis for dosimetry for the clinical application. PMID:28469106
Samper Wamba, J D; Fernández Martínez, A; González Pastrana, L; López González, L; Balboa Arregui, Ó
2015-01-01
To analyze the efficacy and safety of the procedure for placing self-expanding stents in the colon. To evaluate the factors associated with complications. To analyze the dose of radiation delivered in the procedure. This was a retrospective descriptive study of 478 procedures done at a single center to place self-expanding metallic stents in the colon. A total of 423 nitinol stents and 79 stainless steel stents were placed. We included all colonic obstructions, of which 446 had malignant causes and 8 had benign causes. We excluded patients with intestinal perforation, severe colonic bleeding, short life expectancy, or lesions located less than 5 cm from the anus. We collected the dosimetric data and analyzed the technical success, clinical success, and complications during follow-up. The procedure was a technical success in 92.26% of cases (n=441) and a clinical success in 78.45% (n=375); complications occurred during follow-up in 18.5% of cases. Complications occurred more frequently with the stainless steel stents than with the nitinol stents (OR: 3.2; 95% CI: 1.8-5.7). The mean value of the dose area product was 35 Gy*cm(2). When instead of being done by the interventional radiologist working together with an endoscopist the procedure was done exclusively by the interventional radiologist, the time under fluoroscopy (p=0.001), dose area product (p=0.029), and kinetic energy released per unit mass (p=0.001) were greater. The procedure for placing self-expanding colonic stents is efficacious and safe with an acceptable rate of complications. The doses of radiation delivered were low, and the radiation doses and time under fluoroscopy were lower when the procedure was done together with an endoscopist. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Ozretić, David; Radoš, Marko; Pavliša, Goran; Poljaković, Zdravka
2015-01-01
Aim To compare angiographic result at long-term follow-up, and rates of progressive occlusion, recurrence, and retreatment of stent-assisted coiled (SAC) and non-assisted coiled (NAC) intracranial saccular aneurysms. Methods Retrospective evaluation of department records identified 260 patients with 283 saccular intracranial aneurysms who had long-term angiographic follow-up (more than 12 months) and were successfully treated with SAC (89 aneurysms) or NAC (194 aneurysms) at the University Hospital Center Zagreb from June 2005 to July 2012. Initial and control angiographic results in both groups were graded using Roy/Raymond scale, converted to descriptive terms, and the differences between them were evaluated for statistical significance. A multivariate analysis was performed to identify factors related to progression of aneurysm occlusion and recurrence at follow-up, and those related to aneurysm retreatment. Results There were more progressively occluded aneurysms in SAC group (38 of 89 aneurysms, 42.7%) than in NAC group (46 of 194, 23.7%) (P = 0.002), but there were no significant differences in the rates of recanalization, regrowth, and stable result. Multivariate logistic regression identified the use of stent as the most important factor associated with progressive occlusion (P = 0.015, odds ratio 2.22, 95% confidence interval 1.17-4.21), and large aneurysm size and posterior circulation location as most predictive of aneurysm recurrence and retreatment. Conclusion The use of stent is associated with delayed occlusion of initially incompletely coiled aneurysms during follow-up, but does not reduce the rate of recurrence and retreatment compared to coiling alone. Long-term angiographic follow-up is needed for both SAC and NAC aneurysms. PMID:25727039
Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt
2014-07-01
Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral regurgitation, by virtue of their key features as well as effective crimping. These models will be fabricated and put to all the aforementioned tests before being taken for animal trials. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Endovascular stents: a review of their use in peripheral arterial disease.
Kudagi, Vinod S; White, Christopher J
2013-06-01
Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.
Wang, Arthur; Santarelli, Justin G; Stiefel, Michael F
2016-12-01
Optimal management of extracranial carotid artery dissections (eCAD) in pediatric patients is not well documented, and endovascular interventions are rarely reported. A 10-year-old girl sustained multiple systemic injuries in a motor vehicle accident, including an eCAD with pseudoaneurysm. She initially failed both aspirin and endovascular stenting with progressive enlargement of a traumatic cervical carotid pseudoaneurysm and stenosis. Second-stage endovascular stent placement with coiling resulted in successful occlusion of the pseudoaneurysm. At 30-month imaging follow-up, the parent vessel remained patent with no evidence of the pseudoaneurysm. In the setting of poly-trauma, management of eCAD can be complex especially in the pediatric population. There is little data on the endovascular treatment of eCAD in children. Failed endovascular therapies are extremely rare. Our report supports surveillance imaging as repeat endovascular treatment may be necessary.
Li, Liming; Pan, Shuang; Zhou, Xiaohang; Meng, Xin; Han, Xiaoxi; Ren, Yibin; Yang, Ke; Guan, Yifu
2013-01-01
High nitrogen nickel-free austenitic stainless steel (HNNF SS) is one of the biomaterials developed recently for circumventing the in-stent restenosis (ISR) in coronary stent applications. To understand the ISR-resistance mechanism, we have conducted a comparative study of cellular and molecular responses of human umbilical vein endothelial cells (HUVECs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel) which is the stent material used currently. CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profile of HUVECs exposed to HNNF SS and 316L SS, respectively. Flow cytometry analysis revealed that 316L SS could activate the cellular apoptosis more efficiently and initiate an earlier entry into the S-phase of cell cycle than HNNF SS. At the molecular level, qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were overexpressed on 316L SS. Further examination indicated that nickel released from 316L SS triggered the cell apoptosis via Fas-Caspase8-Caspase3 exogenous pathway. These molecular mechanisms of HUVECs present a good model for elucidating the observed cellular responses. The findings in this study furnish valuable information for understanding the mechanism of ISR-resistance on the cellular and molecular basis as well as for developing new biomedical materials for stent applications. PMID:23638002
Iwasaki, Yoshimi; Kubota, Keiichi; Kita, Junji; Katoh, Masato; Shimoda, Mitsugi; Sawada, Tokihiko; Iso, Yukihiro
2013-02-01
The current study was conducted to evaluate the safety and utility of intraoperative transhepatic biliary stenting (ITBS) in patients with unresectable malignant biliary obstruction (UMBO) diagnosed intraoperatively. In this study, 50 patients who underwent ITBS for UMBO between April 2001 and May 2009 were retrospectively reviewed. For 26 patients who underwent preoperative percutaneous transhepatic biliary drainage (PTBD), the expandable metallic stent (EMS) was inserted intraoperatively by the PTBD route in a single stage. For 24 patients, the intrahepatic bile ducts were intentionally dilated by injection of saline via the endoscopic nasobiliary drainage or the percutaneous transhepatic gallbladder drainage route, and the puncture was performed under intraoperative ultrasound guidance followed by guidewire and catheter insertion. Thereafter, the EMS was placed in the same manner. The initial postoperative complications and long-term results of ITBS were evaluated. In all cases, ITBS was technically successful. Stenting alone was performed in 22 patients and stenting combined with other procedures in 28 patients. Hospital mortality occurred for three patients (6 %), and complication-related mortality occurred in two cases (4 %). There were nine cases (18 %) of postoperative complications. The median survival time was 179 days, and the EMS patency time was 137 days. During the follow-up period, EMS occlusion occurred in 23 cases (46 %). Best supportive care was a significant independent risk factor for early mortality within 100 days after ITBS (p = 0.020, odds ratio, 9.398). Single-stage ITBS is feasible for palliation of UMBO and seems to have a low complication rate.
de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed
2016-03-01
In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.
Drug-eluting versus bare-metal coronary stents: where are we now?
Amoroso, Nicholas S; Bangalore, Sripal
2012-11-01
Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).
Tapping, C R; Ahmed, M; Scott, P M; Lakshminarayan, R; Robinson, G J; Ettles, D F; Shrivastava, V
2013-02-01
The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 ± 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 ± -0.15 (right) and 0.61 ± -0.16 (left). After the procedure they were 0.86 ± -0.07 (right) and 0.90 ± -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic disease.
Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms.
Kono, K; Terada, T
2013-10-01
SACE is performed for complex aneurysms. There are several configurations of stent placement for bifurcation aneurysms. We investigated hemodynamics among 8 different configurations of stent placement, which may relate to the recanalization rate. We created a silicone block model of a patient-specific asymmetric bifurcation aneurysm. Enterprise closed-cell stents were deployed in the model as various configurations. 3D images of these stents were obtained by micro-CT. We performed CFD simulations for a no-stent model and 8 stent models: a single stent from a proximal vessel to a right or left distal vessel, a horizontal stent, a kissing-Y stent with a uniformly narrowed structure, a nonoverlapping-Y stent, a virtual-Y stent with no narrowed structure (fusion of 2 single stents), and 2 different crossing-Y stents with a focally narrowed structure. Hemodynamic parameters were evaluated. Cycle-averaged velocity and WSS in the aneurysm were reduced because of stent placement in the following order: single stent (19% reduction in cycle-averaged velocity) < nonoverlapping-Y stent (29%) < virtual-Y stent (32%) < horizontal stent (39%) < kissing-Y stent (48%) < crossing-Y stent (54%). Kissing- and crossing-Y stents redirected impingement flow into the distal vessels because of lowered porosity of stents due to narrowed structures. Among 8 different configurations of stent placement, kissing- and crossing-Y stents showed the strongest reduction in flow velocity in the aneurysm because of lowered porosity of stents and redirection of impingement flow. This may be a desirable reconstruction of flow hemodynamics and may decrease recanalization rates in SACE.
2009-01-01
Background We review urological procedures performed on a spinal cord injury patient during three decades. Case presentation A 23-year-old male patient sustained T-12 paraplegia in 1971. In 1972, intravenous urography showed both kidneys functioning well; division of external urethral sphincter was performed. In 1976, reimplantation of left ureter (Lich-Gregoir) was carried out for vesicoureteric reflux. As reflux persisted, left ureter was reimplanted by psoas hitch-Boari flap technique in 1978. This patient suffered from severe pain in legs; intrathecal injection of phenol was performed twice in 1979. The segment bearing the scarred spinal cord was removed in September 1982. This patient required continuous catheter drainage. Deep median sphincterotomy was performed in 1984. As the left kidney showed little function, left nephroureterectomy was performed in 1986. In an attempt to obviate the need for an indwelling catheter, bladder neck resection and tri-radiate sphincterotomy were carried out in 1989; but these procedures proved futile. UroLume prosthesis was inserted and splinted the urethra from prostatic apex to bulb in October 1990. As mucosa was apposing distal to stent, in November 1990, second UroLume stent was hitched inside distal end of first. In March 1991, urethroscopy showed the distal end of the distal stent had fragmented; loose wires were removed. In April 1991, this patient developed sweating, shivering and haematuria. Urine showed Pseudomonas. Suprapubic cystostomy was performed. Suprapubic cystostomy was done again the next day, as the catheter was pulled out accidentally during night. Subsequently, a 16 Fr Silastic catheter was passed per urethra and suprapubic catheter was removed. In July 1993, Urocoil stent was put inside UroLume stent with distal end of Urocoil stent lying free in urethra. In September 1993, this patient was struggling to pass urine. Urocoil stent had migrated to bladder; therefore, Urocoil stent was removed and a Memotherm stent was deployed. This patient continued to experience trouble with micturition; therefore, Memotherm stent was removed. Currently, wires of UroLume stent protrude in to urethra, which tend to puncture the balloon of urethral Foley catheter, especially when the patient performs manual evacuation of bowels. Conclusion We failed to implement intermittent catheterisation along with anti-cholinergic therapy. Instead, we performed several urological procedures with unsatisfactory outcome; the patient lost his left kidney. We believe that honest review of clinical practice will help towards learning from past mistakes. PMID:20062593
Vaidyanathan, Subramanian; Soni, Bakul M; Hughes, Peter L; Singh, Gurpreet; Mansour, Paul; Oo, Tun
2009-12-16
We review urological procedures performed on a spinal cord injury patient during three decades. A 23-year-old male patient sustained T-12 paraplegia in 1971. In 1972, intravenous urography showed both kidneys functioning well; division of external urethral sphincter was performed. In 1976, reimplantation of left ureter (Lich-Gregoir) was carried out for vesicoureteric reflux. As reflux persisted, left ureter was reimplanted by psoas hitch-Boari flap technique in 1978. This patient suffered from severe pain in legs; intrathecal injection of phenol was performed twice in 1979. The segment bearing the scarred spinal cord was removed in September 1982. This patient required continuous catheter drainage. Deep median sphincterotomy was performed in 1984. As the left kidney showed little function, left nephroureterectomy was performed in 1986. In an attempt to obviate the need for an indwelling catheter, bladder neck resection and tri-radiate sphincterotomy were carried out in 1989; but these procedures proved futile. UroLume prosthesis was inserted and splinted the urethra from prostatic apex to bulb in October 1990. As mucosa was apposing distal to stent, in November 1990, second UroLume stent was hitched inside distal end of first. In March 1991, urethroscopy showed the distal end of the distal stent had fragmented; loose wires were removed. In April 1991, this patient developed sweating, shivering and haematuria. Urine showed Pseudomonas. Suprapubic cystostomy was performed. Suprapubic cystostomy was done again the next day, as the catheter was pulled out accidentally during night. Subsequently, a 16 Fr Silastic catheter was passed per urethra and suprapubic catheter was removed. In July 1993, Urocoil stent was put inside UroLume stent with distal end of Urocoil stent lying free in urethra. In September 1993, this patient was struggling to pass urine. Urocoil stent had migrated to bladder; therefore, Urocoil stent was removed and a Memotherm stent was deployed. This patient continued to experience trouble with micturition; therefore, Memotherm stent was removed. Currently, wires of UroLume stent protrude in to urethra, which tend to puncture the balloon of urethral Foley catheter, especially when the patient performs manual evacuation of bowels. We failed to implement intermittent catheterisation along with anti-cholinergic therapy. Instead, we performed several urological procedures with unsatisfactory outcome; the patient lost his left kidney. We believe that honest review of clinical practice will help towards learning from past mistakes.
Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J
2013-01-01
Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.
Chernin, Gil; Szwarcfiter, Iris; Bausback, Yvonne; Jonas, Michael
2017-05-01
To assess the safety and performance of a nonfocused and nonballooned ultrasonic (US) catheter-based renal sympathetic denervation (RDN) system in normotensive swine. RDN with the therapeutic intravascular US catheter was evaluated in 3 experiments: (i) therapeutic intravascular US RDN vs a control group of untreated animals with follow-up of 30, 45, and 90 days (n = 6; n = 12 renal arteries for each group); (ii) therapeutic intravascular US RDN vs radiofrequency (RF) RDN in the contralateral artery in the same animal (n = 2; n = 4 renal arteries); and (iii) therapeutic intravascular US RDN in a recently stent-implanted renal artery (n = 2; n = 4 renal arteries). In the first experiment, therapeutic intravascular US RDN was safe, without angiographic evidence of dissection or renal artery stenosis. Neuronal tissue vacuolization, nuclei pyknosis, and perineuronal inflammation were evident after RDN, without renal artery wall damage. Norepinephrine levels were significantly lower after therapeutic intravascular US RDN after 30, 45, and 90 days compared with the control group (200.17 pg/mg ± 63.35, 184.75 pg/mg ± 44.51, and 203.43 pg/mg ± 58.54, respectively, vs 342.42 pg/mg ± 79.97). In the second experiment, deeper neuronal ablation penetrance was found with therapeutic intravascular US RDN vs RF RDN (maximal penetrance from endothelium of 7.0 mm vs 3.5 mm, respectively). There was less damage to the artery wall after therapeutic intravascular US RDN than with RF RDN, after which edema and injured endothelium were seen. In the third experiment, denervation inside the stent-implanted segments was feasible without damage to the renal artery wall or stent. The therapeutic intravascular US system performed safely and reduced norepinephrine levels. Deeper penetrance and better preservation of vessel wall were observed with therapeutic intravascular US RDN vs RF RDN. Neuronal ablations were observed in stent-implanted renal arteries. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Zhang, Zong-Ming; Lin, Xiang-Chun; Ma, Li; Jin, An-Qin; Lin, Fang-Cai; Liu, Zhuo; Liu, Li-Min; Zhang, Chong; Zhang, Na; Huo, Li-Juan; Jiang, Xue-Liang; Kang, Feng; Qin, Hong-Jun; Li, Qiu-Yang; Yu, Hong-Wei; Deng, Hai; Zhu, Ming-Wen; Liu, Zi-Xu; Wan, Bai-Jiang; Yang, Hai-Yan; Liao, Jia-Hong; Luo, Xu; Li, You-Wei; Wei, Wen-Ping; Song, Meng-Meng; Zhao, Yue; Shi, Xue-Ying; Lu, Zhao-Hui
2017-06-07
A 48-year-old woman was admitted with 15-mo history of abdominal pain, diarrhea and hematochezia, and 5-mo history of defecation difficulty. She had been successively admitted to nine hospitals, with an initial diagnosis of inflammatory bowel disease with stenotic sigmoid colon. Findings from computed tomography virtual colonoscopy, radiography with meglumine diatrizoate, endoscopic balloon dilatation, metallic stent implantation and later overall colonoscopy, coupled with the newfound knowledge of compound Qingdai pill-taking, led to a subsequent diagnosis of ischemic or toxic bowel disease with sigmoid colon stenosis. The patient was successfully treated by laparoscopic sigmoid colectomy, and postoperative pathological examination revealed ischemic or toxic injury of the sigmoid colon, providing a final diagnosis of drug-induced sigmoid colon stenosis. This case highlights that adequate awareness of drug-induced colon stenosis has a decisive role in avoiding misdiagnosis and mistreatment. The diagnostic and therapeutic experiences learnt from this case suggest that endoscopic balloon expansion and colonic metallic stent implantation as bridge treatments were demonstrated as crucial for the differential diagnosis of benign colonic stenosis. Skillful surgical technique and appropriate perioperative management helped to ensure the safety of our patient in subsequent surgery after long-term use of glucocorticoids.
Zhang, Zong-Ming; Lin, Xiang-Chun; Ma, Li; Jin, An-Qin; Lin, Fang-Cai; Liu, Zhuo; Liu, Li-Min; Zhang, Chong; Zhang, Na; Huo, Li-Juan; Jiang, Xue-Liang; Kang, Feng; Qin, Hong-Jun; Li, Qiu-Yang; Yu, Hong-Wei; Deng, Hai; Zhu, Ming-Wen; Liu, Zi-Xu; Wan, Bai-Jiang; Yang, Hai-Yan; Liao, Jia-Hong; Luo, Xu; Li, You-Wei; Wei, Wen-Ping; Song, Meng-Meng; Zhao, Yue; Shi, Xue-Ying; Lu, Zhao-Hui
2017-01-01
A 48-year-old woman was admitted with 15-mo history of abdominal pain, diarrhea and hematochezia, and 5-mo history of defecation difficulty. She had been successively admitted to nine hospitals, with an initial diagnosis of inflammatory bowel disease with stenotic sigmoid colon. Findings from computed tomography virtual colonoscopy, radiography with meglumine diatrizoate, endoscopic balloon dilatation, metallic stent implantation and later overall colonoscopy, coupled with the newfound knowledge of compound Qingdai pill-taking, led to a subsequent diagnosis of ischemic or toxic bowel disease with sigmoid colon stenosis. The patient was successfully treated by laparoscopic sigmoid colectomy, and postoperative pathological examination revealed ischemic or toxic injury of the sigmoid colon, providing a final diagnosis of drug-induced sigmoid colon stenosis. This case highlights that adequate awareness of drug-induced colon stenosis has a decisive role in avoiding misdiagnosis and mistreatment. The diagnostic and therapeutic experiences learnt from this case suggest that endoscopic balloon expansion and colonic metallic stent implantation as bridge treatments were demonstrated as crucial for the differential diagnosis of benign colonic stenosis. Skillful surgical technique and appropriate perioperative management helped to ensure the safety of our patient in subsequent surgery after long-term use of glucocorticoids. PMID:28638234
Kumar, Sunil; Fusaro, Mario; Amoroso, Nicholas; Kirtane, Ajay J; Byrne, Robert A; Williams, David O; Slater, James; Cutlip, Donald E; Feit, Frederick
2012-01-01
Objectives To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. Design Mixed treatment comparison meta-analysis. Data sources and study selection PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. Primary outcomes Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). Results From 42 trials with 22 844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents∼sirolimus eluting stents>paclitaxel eluting stents∼zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of “any” stent thrombosis. Conclusions Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such that the everolimus eluting stent was the most efficacious and safe. PMID:22885395
Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H
2018-01-01
Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.
Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng
2018-06-22
Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.
Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew
2014-03-01
Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.
Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick
2013-01-01
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased mortality compared with cobalt chromium everolimus eluting stents (1.52, 1.02 to 2.22). Overall, among all stent types, the newer generation durable polymer drug eluting stents (zotarolimus eluting stent-Resolute, cobalt chromium everolimus eluting stents, and platinum chromium everolimus eluting stents) were the most efficacious (lowest target vessel revascularization rate) stents, and cobalt chromium everolimus eluting stents were the safest with significant reductions in definite stent thrombosis (rate ratio 0.35, 0.21 to 0.53), myocardial infarction (0.65, 0.55 to 0.75), and death (0.72, 0.58 to 0.90) compared with bare metal stents. Conclusions Biodegradable polymer drug eluting stents are superior to first generation durable polymer drug eluting stents but not to newer generation durable polymer stents in reducing target vessel revascularization. Newer generation durable polymer stents, and especially cobalt chromium everolimus eluting stents, have the best combination of efficacy and safety. The utility of biodegradable polymer stents in the context of excellent clinical outcomes with newer generation durable polymer stents needs to be proven. PMID:24212107
Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee
2014-01-01
Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.
Enhanced performance of magnesium alloy for drug-eluting vascular scaffold application
NASA Astrophysics Data System (ADS)
Dong, Hongzhou; Li, Daikun; Mao, Daoyong; Bai, Ningning; Chen, Yashi; Li, Qing
2018-03-01
Bio-absorbable magnesium alloys drug-eluting vascular scaffold was developed to resolve the defect of permanent metal and drug-eluting stents, most notably a chronic vessel wall inflammation and the risk of stent thrombosis. Nevertheless, violent chemical reaction and rapid degradation under physiological conditions limits their application. Furthermore, multifunctional drug-eluting stents which could reduce the formation of thrombus and repair the damaged vessels need more attention to fundamentally cure the coronary artery disease. Herein, a drug delivery system (Mg/MgO/PLA-FA) which can realize sustainable release of ferulaic acid was designed via anodic oxidation process and dip coating process. Electrochemical tests and immersion experiments showed that the superior anticorrosion behavior, it is due to the dense MgO-PLA composite layer. The released ferulaic acid can effectively decrease platelets adhesion and aggregation during the early stage of implantation. Besides, hemolysis tests showed that the composite coatings endowed the Mg alloy with a low hemolysis ratio. The Mg/MgO/PLA-FA composite materials may be appropriate for applications on biodegradable Mg alloys drug-eluting stents.
Abelson, Jonathan S; Yeo, Heather L; Mao, Jialin; Milsom, Jeffrey W; Sedrakyan, Art
2017-05-01
Colonic stenting was introduced for palliation of malignant large-bowel obstruction (MLBO) more than 20 years ago but remains controversial. To compare outcomes after palliative stenting vs stoma creation in patients with MLBO requiring emergency management. This observational cohort study assessed 345 patients from New York State with an urgent or emergency admission to the hospital for obstruction secondary to colorectal cancer and who underwent stenting or stoma creation from October 1, 2009, through December 31, 2013. Patients were excluded if they underwent resection within 1 year of the index admission. Palliative stenting vs stoma creation. Primary outcomes included subsequent operation and readmission within 90-day and 1-year follow-up. Secondary outcomes were in-hospital death, major medical and surgical complications, length of stay, total charges, and discharge dispositions. Multivariable hierarchical analyses and propensity score matching were used to compare outcomes between the exposure groups. The cohort included 345 patients (mean [SD] age, 69.9 [14.4] years in the stoma group and 70.9 [16.8] years in the stent group; 87 men [50.3%] in the stoma group and 90 [52.3%] in the stent group; and 114 non-Hispanic white patients [65.9%] in the stoma group and 90 [52.3%] in the stent group). Most patients undergoing stenting were treated at high-volume (104 [60.5%]) vs medium-volume (42 [24.4%]) or low-volume (26 [15.1%]) hospitals (P < .001). Patients undergoing stenting were significantly less likely to experience prolonged length of stay (odds ratio [OR], 0.50; 95% CI, 0.26-0.97; P = .04), more likely to be discharged to their usual residence (OR, 0.14; 95% CI, 0.07-0.28; P < .001), and tended to have similar or fewer complications (major events: OR, 0.81; 95% CI, 0.30-2.18; P = .68; procedural complications: OR, 0.57; 95% CI, 0.11-1.22; P = .10). There was no significant difference between the groups in terms of 90-day and 1-year readmission to the hospitals (90 days: OR, 0.93; 95% CI, 0.49-1.78; P = .83; 1 year: OR, 0.72; 95% CI, 0.38-1.37; P = .30). Subsequent operation at 90 days was also not different between the groups (OR, 1.34; 95% CI, 0.26-6.89; P = .72), but there was a higher chance of subsequent operation at 1 year after the stenting procedure (OR, 2.93; 95% CI, 1.12-7.68; P = .03), with most subsequent operations being restenting. In patients with MLBO and if resection is not part of the treatment plan, stenting is safe and improves the efficiency of care with obvious quality-of-life benefits. It should be offered at experienced centers, and patients should be counseled regarding increased risk of subsequent stenting within 1 year.
Mechanical Characteristics of Composite Knitted Stents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokuda, Takanori, E-mail: tkdtknr@gmail.com; Shomura, Yuzo; Tanigawa, Noboru
2009-09-15
We used metal wires and fibers to fabricate a composite knitted stent and then compare the mechanical characteristics of this stent with those of a pure metallic stent of the same construction in order to develop a stent that offers a comparable degree of expandability as metallic stents but can be used for highly curved lesions that cannot be treated using metallic stents. We fabricated two types of composite knitted stent (N-Z stents), using nitinol wire with a diameter of 0.12 mm and polypara-phenylene-benzobisoxazole (PBO) multifilament fiber (Zyron AS; Toyobo, Osaka, Japan). Stents were knitted into a cylindrical shape usingmore » the same textile pattern as a Strecker stent. Two loop lengths (L) of nitinol wire were used in the N-Z stents: L = 1.84 mm (N-Z stent L = 1.84) and L = 2.08 mm (N-Z stent L = 2.08). For the sake of comparison, we fabricated a metallic stent of nitinol using the same textile pattern (N-N stent L = 1.92). We applied a radial compression force diametrically to each stent and applied a bending force diametrically at the free end of a stent with one end fixed in order to evaluate the relationship between stent elasticity and load values. In addition, we macroscopically evaluated the generation of kinks when the stent was bent 180{sup o}. The radial compressive force when the stent diameter was reduced by 53% was 6.44 N in the case of N-Z stent L = 1.84, 6.14 N in the case of N-Z stent L = 2.08, and 4.96 N in the case of N-N stent L = 1.92 mm. The composite stent had a radial compressive force higher than that of a metallic stent. The restoring force to longitudinal direction at a 90{sup o} bending angle was 0.005 N for N-Z stent L = 1.84, 0.003 N for N-Z stent L = 2.08, and 0.034 N for N-N stent L = 1.92. The restoring force of the composite stent was significantly lower. Finally, the composite stent generated no definitive kinks at a bending angle of 180{sup o}, regardless of loop length. However, the N-N stent clearly produced kinks, causing blockage of the inner cavity. In conclusion, the use of a metal and fiber composite in the construction of a knitted stent ensures an expansion performance comparable to that of metallic stents, while providing better kink resistance.« less
Hickethier, Tilman; Baeßler, Bettina; Kroeger, Jan Robert; Doerner, Jonas; Pahn, Gregor; Maintz, David; Michels, Guido; Bunck, Alexander C
Accurate assessment of coronary stents using non-invasive CT imaging remains challenging despite new stent materials and improvements in CT technology. Virtual monoenergetic (monoE) images reconstructed from dual energy CT acquisitions potentially decrease artifacts caused by coronary stents. A novel spectral detector technology provides monoE and conventional images simultaneously for all conducted scans. The purpose of our study was to systematically investigate the influence of different monoE reconstructions on the visualization of coronary stent lumen in comparison to conventional images. Ten different coronary stents (diameter 3.0 mm) embedded in plastic tubes filled with contrast agent (500 HU) were scanned with a 128-row spectral detector CT (IQon, Philips, 120 kV, 125 mAs). Images were reconstructed (0.67 mm slice thickness, 0.35 mm increment) with a stent-specific conventional reconstruction kernel and 6 different monoE settings (60, 70, 80, 90, 100, 150 keV). Image quality for each stent and reconstruction was quantified using established parameters: image noise (standard deviation (SD) within a standardized ROI), in-stent attenuation difference (mean attenuation difference between stented and non-stented lumen) and visible lumen diameter (mean visible diameter of the stented tube). Image noise was significantly lower in all monoE data dets compared to conventional images (conventional: 13.41, 60 keV: 11.62, 70 keV: 11.67, 80 keV: 11.69, 90 keV: 11.71, 100 keV: 11.75, 150 keV: 11.80 HU SD; p < 0.01). The in-stent attenuation difference was significantly smaller in monoE data with higher keV levels than in conventional images (conventional: 148.18, 60 keV: 154.13 p = 0.036, 70 keV: 143.43 p = 0.109, 80 keV: 137.25 p = 0.052, 90 keV: 133.02 p = 0.043, 100 keV: 130.12 p = 0.039, 150 keV: 123.99 HU p = 0.035). The visible lumen diameter was significantly greater in monoE data with higher keV levels than in conventional images (conventional: 0.65, 60 keV: 0.68 p = 0.542, 70 keV: 0.71 p = 0.053, 80 keV: 0.74 p < 0.01, 90 keV: 0.77 p < 0.01, 100 keV: 0.82 p < 0.01, 150 keV: 0.87 mm p < 0.01). In comparison to conventional CT images, well-established parameters for objective assessment of CT image quality for coronary stents are significantly improved by utilization of monoE reconstructions with adequate keV levels derived from data acquired on a novel spectral detector CT platform. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J
2017-07-01
We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.
MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer.
Korsager, Anne Sofie; Carl, Jesper; Østergaard, Lasse Riis
2013-06-01
In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.
Wykrzykowska, Joanna J; Carrozza, Joseph; Laham, Roger J
2006-08-01
Iatrogenic aortocoronary dissection is a rare but devastating complication of percutaneous coronary interventions and cardiac surgery, with a mortality rate up to 35%. Of the type-A dissections in the International Registry of Aortic Dissections (IRAD), 27% were caused by coronary interventions. The mechanism involves an initial dissection in the coronary artery, which then propagates in a retrograde fashion past the sinuses of Valsalva, often several centimeters beyond the aortic valve. With the advent of complex interventions such as left main stent implantation, revascularization of chronic total occlusions and mechanical thrombectomy, this complication may become more prevalent. Here we present a unique case of percutaneous coronary intervention (PCI) of the left circumflex (LCx) artery complicated by a left main coronary dissection that propagated approximately 8 cm into the ascending aorta and caused abrupt left main coronary artery occlusion and hemodynamic collapse. Rescue of the left main artery and sealing of the aortic dissection with stabilization of the patient was possible with rapid ostial left main artery stenting.
Control of Fibrinogen Assembly by Changing a Polarity of Surfaces
NASA Astrophysics Data System (ADS)
Koo, Jaseung; Liu, Ying; Snow, Sara; Rambhia, Pooja; Koga, Tadanori; Rafailovich, Miriam; Galanakis, Dennis
2009-03-01
Thrombogenesis causes various problems associated with an interruption in the blood flow (e.g., myocardial and cerebral infarction), and a hindrance to use of blood-contact vascular biomaterials (e.g., hemodialysis and cardiopulmonary bypass) with long-term patency since undesired adsorption of blood components occurs on vessels or biomaterials, such as surface-induced thrombosis. we showed that this clotting procedure can be occurred on hydrophobic polymeric surfaces without thrombin cleavage. However, the fibrinogen fibers were not formed on the polar surface such as spun-cast polymer film with pyridine and phenol groups. We also found that αC domains play an important role in initiation of polymerization on surface. Therefore, molecular association was inhibited on the polar surfaces due to confinement of αC chains on the surfaces. These findings were directly applied to stent surface modification. The commercial stent consist of Co-Cr alloy forms undesired fiber formation. However, PS-r-PVPh (13% phenol) coated stent surfaces completely prevent fiber formation.
Jérôme, Christine; Aqil, Abdelhafid; Voccia, Samuël; Labaye, David-Emmanuel; Maquet, Véronique; Gautier, Sandrine; Bertrand, Olivier F; Jérôme, Robert
2006-03-01
This article reports on a novel two-step strategy for the coating of cardiovascular stents by strongly adhering biocompatible and biodegradable aliphatic polyesters. First, a precoating of poly(ethylacrylate) (PEA) was electrografted onto the metallic substrate by cathodic reduction of the parent monomer in dimethylformamide (DMF). The electrodeposition of PEA, in a good solvent of it, was confirmed by both Infra-red and Raman spectroscopies. The pendant ester groups of PEA were then chemically reduced into aluminum alkoxides, able to initiate the ring-opening polymerization (ROP) of either D,L-lactide (LA) or epsilon-caprolactone (CL). Growth of biodegradable PLA or PCL coatings from the adhering precoating was confirmed by both Infra-red and Raman spectroscopies, and directly observed by scanning electron microscopy (SEM). This type of coating can act as an anchoring layer for the subsequent casting of drug-loaded polyester films allowing the controlled release of antiproliferative agents for the treatment of in-stent restenosis. (c) 2005 Wiley Periodicals, Inc.
Scheller, Bruno; Speck, Ulrich; Romeike, Bernd; Schmitt, Alexander; Sovak, Milos; Böhm, Michael; Stoll, Hans Peter
2003-08-01
Lipophilic taxanes can be dissolved in contrast media at significantly higher concentration than in saline. As contrast media have occasionally been observed to delineate the contour of coronary arteries for some seconds they may serve as a matrix for an antiproliferative drug aimed at preventing restenosis. The aim of this study was to test a novel taxane-contrast agent formulation for this new approach in the setting of coronary stenting. In cell culture experiments (bovine vascular smooth muscle cells), 60-min incubation with contrast agent-taxane formulations (iopromide-paclitaxel, iopromide-protaxel) induced a significant, concentration-dependent inhibition of vascular smooth muscle cell (VSMC) proliferation over 12 days. Shorter incubation times of 10 and 3 min showed the same efficacy. For in vivo investigation, 16 stents were implanted into the coronary arteries of eight pigs using a 1.3 to 1 overstretch ratio. A control group received iopromide 370 alone while the treatment group was injected with a iopromide-protaxel formulation at a dose of 74 micromol/l, which is far below protaxel levels inducing systemic toxicity. Quantitative angiography and histomorphometry of the stented arteries asserted statistic equality of the baseline parameters between the control and treatment groups. After 28 days, the treatment group showed a marked reduction of the parameters characterizing in-stent restenosis, especially a 34% reduction of the neointimal area. First evidence is provided that using a contrast agent as solvent for a taxane constitutes a new drug delivery mechanism able to inhibit in-stent restenosis in the porcine restenosis model.
Everett, Kay D.; Conway, Claire; Desany, Gerard J.; Baker, Brian L.; Choi, Gilwoo; Taylor, Charles A.; Edelman, Elazer R.
2016-01-01
Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006–2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices. PMID:26467552
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Jeong-Ho; Kang, Jihoon; Yeo, Min-Ju
PurposeCarotid endarterectomy and stenting are used to treat carotid stenosis, with the volume of carotid artery procedures increasing over the past decade. We investigated the 10-year trend of periprocedural complications with an increasing procedure volume of carotid stenting at a single tertiary hospital.MethodsWe collected 416 consecutive cases (384 patients) of carotid artery stenting performed for either symptomatic (231 cases, 55.5 %) or asymptomatic (185 cases, 44.5 %) internal carotid artery stenosis at a single center. Periprocedural complication was defined as any stroke, myocardial infarction, or death. Procedure-related outcome included any dissection, hemodynamic event, or periprocedural complication.ResultsThe mean age was 68.8 years (82.8 % males;more » range of 20–89 years); 23.9 % were older than 75 years. Before the procedure, 99.3 and 56.0 % of patients received antiplatelet and lipid-lowering medication, respectively. The overall periprocedural complication rate was 3.6 % (1.6 and 5.2 % in the asymptomatic and symptomatic group, respectively). The composite outcome of any stroke or death was 3.4 %. Periprocedural complication and procedure-related outcome showed a decremental trend with increasing procedure volume, and this trend remained after adjusting for confounders.ConclusionsOur study suggests that carotid stenting at an experienced center might reduce the periprocedural complications. Our periprocedural complication rate of carotid artery stenting may be comparable to, or somewhat lower than, that reported in other clinical trials.« less
Everett, Kay D; Conway, Claire; Desany, Gerard J; Baker, Brian L; Choi, Gilwoo; Taylor, Charles A; Edelman, Elazer R
2016-02-01
Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006-2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices.
Cho, Su-hee; Jo, Won-il; Jo, Ye-eun; Yang, Ku Hyun; Park, Jung Cheol
2017-01-01
Purpose To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. Materials and Methods Four different types of stents that are currently being used for cerebral aneurysm embolization were prepared (two stents per type). Two were laser-cut stents (Neuroform and Enterprise) and two were braided from a single nitinol wire (LEO and LVIS stents). All were subjected to quantitative measurements of stent size, pore density, metal coverage, the force needed to load, push, and deploy the stent, radial force on deployment, surface roughness, and corrosion resistance. Results Compared to their nominal diameters, all stents had greater diameters after deployment. The length generally decreased after deployment. This was particularly marked in the braided stents. The braided stents also had higher pore densities than the laser-cut stents. Metal coverage was highest in the LEO stent (14%) and lowest in the Enterprise stent (5%). The LIVS stent had the highest microcatheter loading force (81.5 gf). The LEO stent had the highest passage force (55.0 gf) and deployment force (78.9 gf). The LVIS and LEO stents had the highest perpendicular (37.1 gf) and circumferential (178.4 gf) radial forces, respectively. The Enterprise stent had the roughest stent wire, followed by the LVIS, LEO, and Neuroform stents. Conclusion The four neurovascular stent types differed in terms of morphological and physical characteristics. An understanding of this diversity may help to decide which stent is most suitable for specific clinical situations. PMID:28316867
Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R
2011-01-01
Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363
NASA Astrophysics Data System (ADS)
Furdella, Kenneth J.; Witte, Russell S.; Vande Geest, Jonathan P.
2017-04-01
Although the drug-eluting stent (DES) has dramatically reduced the rate of coronary restenosis, it still occurs in up to 20% of patients with a DES. Monitoring drug delivery could be one way to decrease restenosis rates. We demonstrate real-time photoacoustic imaging and spectroscopy (PAIS) using a wavelength-tunable visible laser and clinical ultrasound scanner to track cardiac drug delivery. The photoacoustic signal was initially calibrated using porcine myocardial samples soaked with a known concentration of a drug surrogate (DiI). Next, an in situ coronary artery was perfused with DiI for 20 min and imaged to monitor dye transport in the tissue. Finally, a partially DiI-coated stent was inserted into the porcine brachiocephalic trunk for imaging. The photoacoustic signal was proportional to the DiI concentration between 2.4 and 120 μg/ml, and the dye was detected over 1.5 mm from the targeted coronary vessel. Photoacoustic imaging was also able to differentiate the DiI-coated portion of the stent from the uncoated region. These results suggest that PAIS can track drug delivery to cardiac tissue and detect drugs loaded onto a stent with sub-mm precision. Future work using PAIS may help improve DES design and reduce the probability of restenosis.
Aparício, Dayse Pereira da Silva; Otoch, José Pinhata; Montero, Edna Frasson de Souza; Artifon, Everson Luiz de Almeida
2016-01-01
The most common biliary complication after liver transplantation is anastomotic stricture (AS) and it can occur isolated or in combination with other complications. Liver graft from a cadaveric donor or a living donor has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. Endoscopic treatment using balloon dilation and insertion of biliary stents by endoscopic retrograde cholangiopancreatography (ERCP) is the initial approach to these complications. Aim The aim of this article is to compare different endoscopic techniques to treat post-liver transplantation biliary strictures. Methods The search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases through June 2015. A total of 1100 articles were retrieved. Ten clinical trials were analyzed, and seven were included in the meta-analysis. Conclusions The endoscopic treatment of AS was equally effective when compared the use of fully covered self-expandable metal stents (FCSEMS) vs. plastic stents, but the use of FCSEMS was associated with a lower complication risk. The treatment of AS with balloon dilation or balloon dilation associated with plastic stents presented similar results. Deceased donor liver transplantation reduced the risk of biliary stenosis and the endoscopic treatment in these patients was more effective when compared with Living donor liver transplantation. PMID:29026597
Malignant Ureteral Obstruction: Functional Duration of Metallic versus Polymeric Ureteral Stents
Chow, Po-Ming; Chiang, I-Ni; Chen, Chia-Yen; Huang, Kuo-How; Hsu, Jui-Shan; Wang, Shuo-Meng; Lee, Yuan-Ju; Yu, Hong-Jeng; Pu, Yeong-Shiau; Huang, Chao-Yuan
2015-01-01
Background Ureteral obstruction caused by extrinsic compression is often associated with intra-abdominal cancers. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. Novel designs of ureteral stents made of different materials have been invented to achieve better drainage. In this study, we described the functional outcomes of a Resonance metallic ureteral stent (Cook Medical, Bloomington, Indiana, USA) in patients with malignant ureteral obstruction and compare the functional duration of Resonance stents with regular polymeric stents in the same cohort. Methods Cancer patients who received polymeric stents and subsequent Resonance stents for ureteral obstruction between July 2009 and November 2012 were included in a chart review. Stent failure was detected by clinical symptoms, imaging studies, and renal function tests. The functional durations of each stent were calculated, and possible factors affecting stent patency were investigated. Results A total of 50 stents were successfully inserted into 50 ureteral units in 42 patients with malignant ureteral obstruction. There were 7 antegrade stents and 43 retrograde stents. There were no major complications. Stent-related symptoms were similar in both kinds of stents. After polymeric stents were replaced with Resonance metallic stents, hydronephrosis subsided or remained stable in 90% (45/50) of the ureteral units. Serum creatinine decreased or remained stable in 90% (38/42) of these patients. The Resonance stent exhibited a mean increase in functional duration of 4 months compared with the polymeric stents (p<0.0001), and 50% (25/50) of the Resonance stents exhibited a significant increase in functional duration (more than 3 months). Pre-operative serum creatinine < 2 was associated with a substantial increase in stent duration. Conclusions Resonance stents are effective and safe in relieving malignant ureteral obstructions after polymeric stents failure. Resonance stents can provide a longer functional duration than polymeric stents and should be offered as an option for internal drainage. PMID:26267140
Standards in capstone design courses and the engineering curriculum.
Goldberg, Jay
2012-01-01
In 1990, I was the group leader of Research and Development for Surgitek, a urological device manufacturer in Racine, Wisconsin, which was the market leader in ureteral stents. I recognized the need for an industry standard for ureteral stents, felt that taking a leadership role in the development of a new standard would be a good professional development activity, and volunteered to serve as the chair of the American Society for Testing and Materials (ASTM, now known as ASTM International) Task Group on Ureteral Stents. After several years, the standard was approved, and I continue to serve as the chair of the ASTM Subcommittee on Urological Materials and Devices. This experience helped me understand the value of industry standards, expanded my professional network and visibility within the medical device industry, and helped develop my leadership skills.
Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin
2014-06-01
To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.
Spaander, Manon C W; Baron, Todd H; Siersema, Peter D; Fuccio, Lorenzo; Schumacher, Brigitte; Escorsell, Àngels; Garcia-Pagán, Juan-Carlos; Dumonceau, Jean-Marc; Conio, Massimo; de Ceglie, Antonella; Skowronek, Janusz; Nordsmark, Marianne; Seufferlein, Thomas; Van Gossum, André; Hassan, Cesare; Repici, Alessandro; Bruno, Marco J
2016-10-01
This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE), endorsed by the European Society for Radiotherapy and Oncology (ESTRO), the European Society of Digestive Endoscopy (ESDO), and the European Society for Clinical Nutrition and Metabolism (ESPEN). The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations for malignant disease 1 ESGE recommends placement of partially or fully covered self-expandable metal stents (SEMSs) for palliative treatment of malignant dysphagia over laser therapy, photodynamic therapy, and esophageal bypass (strong recommendation, high quality evidence). 2 For patients with longer life expectancy, ESGE recommends brachytherapy as a valid alternative or in addition to stenting in esophageal cancer patients with malignant dysphagia. Brachytherapy may provide a survival advantage and possibly a better quality of life compared to SEMS placement alone. (Strong recommendation, high quality evidence.) 3 ESGE recommends esophageal SEMS placement as the preferred treatment for sealing malignant tracheoesophageal or bronchoesophageal fistula (strong recommendation, low quality evidence). 4 ESGE does not recommend the use of concurrent external radiotherapy and esophageal stent treatment. SEMS placement is also not recommended as a bridge to surgery or prior to preoperative chemoradiotherapy. It is associated with a high incidence of adverse events and alternative satisfactory options such as placement of a feeding tube are available. (Strong recommendation, low quality evidence.) Main recommendations for benign disease 1 ESGE recommends against the use of self-expandable stents (SEMSs) as first-line therapy for the management of benign esophageal strictures because of the potential for adverse events, the availability of alternative therapies, and costs (strong recommendation, low quality evidence). 2 ESGE suggests consideration of temporary placement of SEMSs as therapy for refractory benign esophageal strictures (weak recommendation, moderate evidence). Stents should usually be removed at a maximum of 3 months (strong recommendation, weak quality evidence). 3 ESGE suggests that fully covered SEMSs be preferred over partially covered SEMSs for the treatment of refractory benign esophageal strictures, because of their lack of embedment and ease of removability (weak recommendation, low quality evidence). 4 For the removal of partially covered esophageal SEMSs that are embedded, ESGE recommends the stent-in-stent technique (strong recommendation, low quality evidence). 5 ESGE recommends that temporary stent placement can be considered for treating esophageal leaks, fistulas, and perforations. The optimal stenting duration remains unclear and should be individualized. (Strong recommendation, low quality evidence.) 6 ESGE recommends placement of a SEMS for the treatment of esophageal variceal bleeding refractory to medical, endoscopic, and/or radiological therapy, or as initial therapy for patients with massive esophageal variceal bleeding (strong recommendation, moderate quality evidence). © Georg Thieme Verlag KG Stuttgart · New York.
Guan, Ying; Wang, Lu; Lin, Jing; King, Martin W.
2016-01-01
Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft. PMID:28773781
Finite Element Analysis of the Implantation Process of Overlapping Stents
Xu, Jiang; Yang, Jie; Sohrabi, Salman; Zhou, Yihua; Liu, Yaling
2017-01-01
Overlapping stents are widely used in vascular stent surgeries. However, the rate of stent fractures (SF) and in-stent restenosis (ISR) after using overlapping stents is higher than that of single stent implantations. Published studies investigating the nature of overlapping stents rely primarily on medical images, which can only reveal the effect of the surgery without providing insights into how stent overlap influences the implantation process. In this paper, a finite element analysis of the overlapping stent implantation process was performed to study the interaction between overlapping stents. Four different cases, based on three typical stent overlap modes and two classical balloons, were investigated. The results showed that overlapping contact patterns among struts were edge-to-edge, edge-to-surface, and noncontact. These were mainly induced by the nonuniform deformation of the stent in the radial direction and stent tubular structures. Meanwhile, the results also revealed that the contact pressure was concentrated in the edge of overlapping struts. During the stent overlap process, the contact pattern was primarily edge-to-edge contact at the beginning and edge-to-surface contact as the contact pressure increased. The interactions between overlapping stents suggest that the failure of overlapping stents frequently occurs along stent edges, which agrees with the previous experimental research regarding the safety of overlapping stents. This paper also provides a fundamental understanding of the mechanical properties of overlapping stents. PMID:28690712
Lettau, Michael; Bendszus, Martin; Hähnel, Stefan
2013-06-01
Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.
Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K
2013-02-01
To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P < 0.05) at 1.5 and 3 T. Maximum visible stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.
Geiger, Timothy M; Miedema, Brent W; Tsereteli, Zurab; Sporn, Emanuel; Thaler, Klaus
2008-10-01
Permanent metal stent placement for malignant intestinal obstruction has been proven to be efficient. Temporary stents for benign conditions of the colon and rectum are less studied. This is a case study, review of the literature, and observation from an animal model on placement of stents in the colorectum for benign disease. A 55-year-old man presented with recurrent obstructions from a benign stricture of the distal sigmoid colon. After failed balloon dilations, a polyester coated stent was placed. The purpose of the stent was to improve symptoms and avoid surgery. The stent was expelled after 5 days. We conducted a literature review of stents placed for benign colorectal strictures and an animal study to evaluate stent migration. In the literature, there were 53 reports of uncovered metal stents, four covered metal stents, and six polyester stents. Patency rates were 71%, and migration rate was 43%. Migration occurred earlier with polyester stents (mean=8 days) versus covered (32 days) or uncovered metal stents (112 days). Severe complications were seen in 23% of patients. Four 45-kg pigs underwent rectosigmoid transection with a 21-mm anastomosis and endoscopic placement of a Polyflex stent. Two stents were secured with suture. Stents without fixation were expelled within 24 h of surgery. Stents with fixation were expelled between postoperative days 2 and 14. Stents for the treatment of benign colorectal strictures are safe, with comparable patency rates between stent types. Metal stents can cause severe complications. In a pig model, covered polyester stents tend to migrate early even with fixation. Further investigation needs to focus on new stent designs and/or better fixation.
Matsumoto, Kazuyuki; Kato, Hironari; Tsutsumi, Koichiro; Mizukawa, Sho; Yabe, Syuntaro; Seki, Hiroyuki; Akimoto, Yutaka; Uchida, Daisuke; Tomoda, Takeshi; Yamamoto, Naoki; Horiguchi, Shigeru; Kuwaki, Kenji; Okada, Hiroyuki
2017-07-01
Few reports describe the endoscopic double-stenting procedure for malignant biliary and duodenal obstructions. We evaluated the clinical outcomes from double stenting, and analyzed the risk factors for biliary stent dysfunction following double stenting. Eighty-one patients who underwent endoscopic double stenting for malignant biliary and duodenal obstructions were retrospectively analyzed. We determined the stent dysfunction rate and the biliary stent dysfunction risk factors, and analyzed the endoscopic reintervention results. Overall survival time and survival time following double stenting were 365 (38-1673) days and 73 (20-954) days, respectively. After double stenting, the 3-month and 6-month duodenal stent dysfunction rates were 14% and 41%, respectively. Reintervention technical success rate was 100% (10/10), and mean gastric outlet obstruction scoring system scores improved from 0.7 to 2.4 points (P < 0.001). The 3-month and 6-month biliary stent dysfunction rates were 26% and 41%, respectively. The reintervention technical and clinical success rates were 95% (20/21) and 81% (17/21), respectively. Risk factors for biliary stent dysfunction following double stenting were events associated with duodenal stent dysfunction (odds ratio [OR], 11.1; 95% confidence interval [CI], 2.09-87.4; P = 0.0044) and the biliary stent end's location (OR, 6.93; 95% CI, 1.37-40.2; P = 0.0019). Some patients had stent dysfunction irrespective of the survival period after double stenting. Endoscopic reintervention was technically feasible and clinically effective even after double stenting. Duodenal stent dysfunction and biliary stent end's location were risk factors for biliary stent dysfunction. © 2017 Japan Gastroenterological Endoscopy Society.
A repositionable valved stent for endovascular treatment of deteriorated bioprostheses.
Zegdi, Rachid; Khabbaz, Ziad; Borenstein, Nicolas; Fabiani, Jean-Noël
2006-10-03
We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. Five sheep underwent, on beating heart, tricuspid VR with a stented BP. Prolapse of 1 leaflet was induced by tearing. For the endovascular tricuspid VR, we used a VS constructed with a nitinol self-expandable stent and a porcine stentless aortic valve. We also used an original delivery catheter, allowing repositioning of the VS through a compression or relaxation mechanism of the stent. Epicardial echocardiography and right ventriculography showed severe tricuspid regurgitation, with a regurgitant jet extending to the inferior vena cava. After surgical exposure to the infrarenal inferior vena cava, the VS was successfully implanted inside the failed BP in all cases. Repositioning of the fully deployed VS was always possible. Echocardiographic and macroscopic studies revealed adequate VS positioning, excellent leaflet opening, and absence of any intraprosthetic or periprosthetic leak. Endovascular VR was easily performed in sheep with failed BP in the tricuspid position. The novel delivery catheter allowed adequate repositioning of our fully deployed VS before its definitive release. One may anticipate that the safety improvement conferred by this new technology will certainly favor the development of percutaneous VR in clinical practice.
Okamoto, Naotaka; Ueda, Hiroshi; Yoshimura, Takahiro; Chamaria, Surbhi; Bhatheja, Samit; Vengrenyuk, Yuliya; Rabiei, Samaneh; Barrientos, Yonandy; Kapur, Vishal; Barman, Nitin; Sweeny, Joseph; Baber, Usman; Mehran, Roxana; Sharma, Samin K; Kini, Annapoorna S
2018-04-15
The aim of the study was to compare the acute outcomes of Absorb bioresorbable vascular scaffolds (BVS) and second-generation drug-eluting stent (DES) implantation in routine clinical practice. There is a paucity of data regarding BVS use in a real-world patient population. The study population comprised 40 consecutive patients who underwent percutaneous coronary intervention (PCI) with BVS implantation at a tertiary-care center in New York, New York between July and December of 2016. An optimal implantation technique including adequate lesion preparation, mandatory postdilation, and optical coherence tomography (OCT) imaging was used in all cases. De novo lesions treated with BVS were compared to lesions treated with DES matched by OCT calcium arc, scaffold/stent size, use of atherectomy device, and lesion postdilation. Acute lumen gain, minimal device area, malapposition, eccentricity, and symmetry index were assessed using OCT. We analyzed OCT images of 40 BVS cases and 40 matching DES cases from 35 and 40 patients, respectively. Compared to the DES group, the BVS group demonstrated similar acute lumen gain, minimal scaffold/stent area, eccentricity index, and symmetry index after PCI. There were fewer malapposed struts detected after BVS implantation; however, malapposition distance and length were not different between the groups. BVS implantation in a real-world patient population with optimal implantation technique resulted in similar stent expansion and better strut apposition compared to DES implantation.
Magnetic navigation for thoracic aortic stent-graft deployment using ultrasound image guidance.
Luo, Zhe; Cai, Junfeng; Wang, Su; Zhao, Qiang; Peters, Terry M; Gu, Lixu
2013-03-01
We propose a system for thoracic aortic stent-graft deployment that employs a magnetic tracking system (MTS) and intraoperative ultrasound (US). A preoperative plan is first performed using a general public utilities-accelerated cardiac modeling method to determine the target position of the stent-graft. During the surgery, an MTS is employed to track sensors embedded in the catheter, cannula, and the US probe, while a fiducial landmark based registration is used to map the patient's coordinate to the image coordinate. The surgical target is tracked in real time via a calibrated intraoperative US image. Under the guidance of the MTS integrated with the real-time US images, the stent-graft can be deployed to the target position without the use of ionizing radiation. This navigation approach was validated using both phantom and animal studies. In the phantom study, we demonstrate a US calibration accuracy of 1.5 ± 0.47 mm, and a deployment error of 1.4 ± 0.16 mm. In the animal study, we performed experiments on five porcine subjects and recorded fiducial, target, and deployment errors of 2.5 ± 0.32, 4.2 ± 0.78, and 2.43 ± 0.69 mm, respectively. These results demonstrate that delivery and deployment of thoracic stent-graft under MTS-guided navigation using US imaging is feasible and appropriate for clinical application.
Non-traumatic perforation of common hepatic duct: Case report and review of literature HP.
Atwez, Abdelaziz; Augustine, Matthew; Nottingham, James M
2017-01-01
Non-traumatic biliary perforation other than the gallbladder is extremely rare and most commonly seen in children in association with congenital biliary anomalies. We present a rare case of choledocholithiasis that progressed to spontaneous perforation of the common hepatic duct probably from ischemic necrosis caused by impaction of large biliary stones. A 62-year-old female presented with diarrhea and jaundice. She was found to have two 2.5cm stones in the common hepatic duct. Stones could not be extracted by ERCP, and placement of biliary stent was done to restore patency. The patient was lost to follow up and returned after three months with a new onset of similar symptoms. At that time ERCP and a stent change were done without resolution of the symptoms. Patient then underwent an open exploration and was found to have a free perforation in the lateral aspect of the common hepatic duct just at the bifurcation of the right and left hepatic radicals. Through this perforation stones were both extracted and cholangiogram showed free flow with the distal biliary stent. The stent was nowhere near the site of perforation which appeared to be caused by pressure necrosis from the impacted stones. Impacted stones in the biliary tree need to be extracted to avoid pressure necrosis and spontaneous perforation. ERCP and stent placement should be used only as temporizing measures to manage the acute obstructive phase. Definitive surgical intervention must follow initial biliary decompression to extract the impacted biliary stones and avoid complications. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Recent advances in endovascular treatment of aortoiliac occlusive disease.
Kavaliauskienė, Zana; Antuševas, Aleksandras; Kaupas, Rytis Stasys; Aleksynas, Nerijus
2012-01-01
The rate of endovascular interventions for iliac occlusive lesions is continuously growing. The evolution of the technology supporting these therapeutic measures improves the results of these interventions. We performed a review of the literature to report and appreciate short- and long-term results of endovascular stenting of iliac artery occlusive lesions. The Medline database was searched to identify all the studies reporting iliac artery stenting for aortoiliac occlusive disease (Trans Atlantic Inter-Society Consensus [TASC] type A, B, C, and D) from January 2006 to July 2012. The outcomes were technical success, long-term primary and secondary patency rates, early mortality, and complications. Technical success was achieved in 91% to 99% of patients as reported in all the analyzed articles. Early mortality was described in 5 studies and ranged from 0.7% to 3.6%. The most common complications were access site hematomas, distal embolization, pseudoaneurysms, and iliac artery ruptures. The complications were most often treated conservatively or using percutaneous techniques. The 5-year primary and secondary patency rates ranged from 63% to 88% and 86% to 93%, respectively; and the 10-year primary patency rates ranged from 68% to 83%. In this article, combined percutaneous endovascular iliac stenting and infrainguinal surgical reconstructions and new techniques in the treatment of iliac stent restenosis are discussed. Iliac stenting is a feasible, safe, and effective method for the treatment of iliac occlusive disease. Initial technical and clinical success rates are high; early mortality and complication rates are low. Long-term patency is comparable with that after bypass surgery.
Jones, Lauren E Beste
2005-01-01
The use of endovascular stent grafts is a leading technological advancement in the treatment of thoracic aortic aneurysms, and is being trialed in the United States as an alternative to medical management and traditional surgical repair. Aortic stent grafts, initially used only for abdominal aortic aneurysms, have been used for over 10 years in Europe and are currently under United States Food and Drug Administration investigation for the treatment of chronic and acute aortic aneurysms. Diseases of the thoracic aorta are often present in high-risk individuals, and, as a result, there is a high morbidity and mortality rate associated with both medical and surgical management of these patients. The development and refinement of endovascular approaches have the potential to decrease the need for traditional surgical repair, especially in high-risk populations such as the elderly and those with multiple comorbidities. Endovascular technology for thoracic repair has only been used in Europe for the last 10 years, with no long-term outcomes available; however, preliminary research demonstrates favorable early and midterm outcomes showing that endovascular stent graft placement to exclude the dilated, dissected, or ruptured aorta is both technically feasible and safe for patients. The article highlights the historical perspective of endovascular stent grafting as well as a description of patient selection, the operative procedure, benefits, risks, and unresolved issues pertaining to the procedure. A brief review of aneurysm and dissection pathophysiology and management is provided, as well as postoperative management for acute care nurses and recommendations for clinical practice.
Lam, Ming Kai; Sen, Hanim; Tandjung, Kenneth; van Houwelingen, K Gert; de Vries, Arie G; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; Löwik, Marije M; Linssen, Gerard C M; Ijzerman, Maarten J; van der Palen, Job; Doggen, Carine J M; von Birgelen, Clemens
2014-04-01
To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome. Copyright © 2014 The Authors. Published by Mosby, Inc. All rights reserved.
Kono, Kenichi; Shintani, Aki; Terada, Tomoaki
2014-01-01
It is necessary to consider possibility of recanalization and retreatment after coil embolization for cerebral aneurysms. There is concern that retreatment for recanalized aneurysms after Y-stent-assisted coil embolization may be difficult because of double stents, especially in Y-stents with double closed-cell stents owing to narrowed structures. However, no detailed reports of retreatment after Y-stent have been reported. Between July 2010 and June 2013, we treated four aneurysms with Y-stent-assisted coil embolization using Enterprise closed-cell stents. Recanalization occurred in one case (25%), and retreatment was performed. We easily navigated a microcatheter into the target portions of the aneurysm through the Y-stent and occluded the aneurysm with coils. Additionally, by systematically searching in PubMed, we found 105 cases of Y-stent-assisted coil embolization using Enterprise stents or Neuroform stents with more than 6 months of follow-up. Among them, retreatment was performed in 10 cases (9.5%). There were no significant differences in retreatment rates among different stent combinations (P=0.91; Fisher's exact test). In conclusion, navigation of a microcatheter into the aneurysm through the Y-stent with double Enterprise stents was feasible, and retreatment rates after Y-stent-assisted coiling may not depend on stent combinations.
Ishiwatari, Hirotoshi; Hayashi, Tsuyoshi; Ono, Michihiro; Sato, Tsutomu; Kato, Junji
2013-05-01
Plastic stent (PS) occlusion occurs as a result of bacterial adherence to the stent's inner wall. To retain the bacteriological barrier, placing a PS above the sphincter of Oddi ('inside stent') has been investigated. We designed a new PS (inside stent with thread [IT] stent) with attachable nylon thread for use as an inside stent and for easy retrieval. The present study evaluated the IT stent's technical feasibility and efficacy for malignant hilar biliary obstruction. A total of 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent placement of IT stents from August 2007 to February 2011. IT stents were placed across the strictures without sphincterotomy to achieve bilateral drainage. The overall technical success rate of the IT stent was 100% for one session. Multiple IT stents were inserted in 25 cases(two stents in 15 patients, three stents in 10 patients). No stent-related early complications occurred. The functional success rate was 92% (24/26). The rate of reintervention because of stent malfunction was 50% (13/26). In all 16 patients who underwent stent removal, IT stents were easily retrieved using the nylon thread. According to Kaplan-Meier analysis, the median stent patency period was 136 days. IT stents for endoscopic placement above the sphincter of Oddi can be used safely and effectively for malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Predictors of early stent occlusion among plastic biliary stents.
Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K
2012-09-01
A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.
van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E
2013-01-01
Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P < .001) was a risk factor for adverse events during stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilhelm, K.E., E-mail: wilhelm@uni-bonn.de; Grabolle, B.; Urbach, H.
2006-10-15
The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted withoutmore » major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency.« less
Yang, Dennis; Nieto, Jose M; Siddiqui, Ali; Riff, Brian P; DiMaio, Christopher J; Nagula, Satish; Ismail, Amr M; Ngamreungphong, Saowanee; Khashab, Mouen A; Wagh, Mihir S; Tzimas, Demetrios; Buscaglia, Jonathan M; Strand, Daniel S; Wang, Andrew Y; Chauhan, Shailendra S; Forsmark, Christopher E; Draganov, Peter V
2017-04-01
Background and study aim Use of the fully covered self-expandable metal stent (SEMS) for benign luminal gastrointestinal (GI) stricture (BLGS) has been limited by the migration rate. The role of the lumen-apposing metal stent (LAMS) for BLGS is not well defined. We assessed the safety, feasibility, and efficacy of LAMS for the treatment of BLGS. Patients and methods This was an observational, open-label, retrospective, single-arm, multicenter consecutive case series of patients undergoing LAMS placement for BLGS. Technical success was defined as successful placement of the LAMS. Short- and long-term clinical success rates were defined as symptom improvement/resolution with indwelling stent and after stent removal, respectively. All adverse events and additional interventions were recorded. Results A total of 30 patients (mean age 51.6 years; 63.3 % women) underwent LAMS placement for GI strictures (83.9 % anastomotic). Median stricture diameter and length were 4.5 mm (range 2 - 10 mm) and 8 mm (range 5 - 10 mm), respectively. Technical success was achieved in 29 patients (96.7 %), with an adverse event rate of 13.3 %. The stent migration rate was 8.0 % (2/25) on follow-up endoscopy. Short-term clinical success was achieved in 90.0 % (27/30) at a median of 60 days (interquartile range [IQR] 40 - 90 days). Most patients (19/23; 82.6 %) experienced sustained symptom improvement/resolution without the need for additional interventions at a median follow-up of 100 days (IQR 60 - 139 days) after LAMS removal. Conclusion This multicenter study demonstrated that LAMS placement represents a safe, feasible, and effective therapeutic option for patients with BLGS and is associated with a low stent migration rate. Our initial findings suggest that future prospective comparative studies are needed on the use of LAMS, endoscopic dilation, and conventional SEMS. . © Georg Thieme Verlag KG Stuttgart · New York.
Müller, Martin; Seufferlein, Thomas; Perkhofer, Lukas; Wagner, Martin; Kleger, Alexander
2015-01-01
Despite a pronounced reduction of lethality rates due to upper gastrointestinal bleeding, esophageal variceal bleeding remains a challenge for the endoscopist and still accounts for a mortality rate of up to 40% within the first 6 weeks. A relevant proportion of patients with esophageal variceal bleeding remains refractory to standard therapy, thus making a call for additional tools to achieve hemostasis. Self-expandable metal stents (SEMS) incorporate such a tool. We evaluated a total number of 582 patients admitted to our endoscopy unit with the diagnosis "gastrointestinal bleeding" according to our documentation software between 2011 and 2014. 82 patients suffered from esophageal variceal bleeding, out of which 11 cases were refractory to standard therapy leading to SEMS application. Patients with esophageal malignancy, fistula, or stricture and a non-esophageal variceal bleeding source were excluded from the analysis. A retrospective analysis reporting a series of clinically relevant parameters in combination with bleeding control rates and adverse events was performed. The initial bleeding control rate after SEMS application was 100%. Despite this success, we observed a 27% mortality rate within the first 42 days. All of these patients died due to non-directly hemorrhage-associated reasons. The majority of patients exhibited an extensive demand of medical care with prolonged hospital stay. Common complications were hepatic decompensation, pulmonary infection and decline of renal function. Interestingly, we found in 7 out of 11 patients (63.6%) stent dislocation at time of control endoscopy 24 h after hemostasis or at time of stent removal. The presence of hiatal hernia did not affect obviously stent dislocation rates. Refractory patients had significantly longer hospitalization times compared to non-refractory patients. Self-expandable metal stents for esophageal variceal bleeding seem to be safe and efficient after failed standard therapy. Stent migration appeared to be a common incident that did not lead to reactivation of bleeding in any of our patients. SEMS should be considered a reasonable treatment option for refractory esophageal variceal bleeding after treatment failure of ligature and sclerotherapy and non-availability of or contraindication for other measures (e.g. TIPS).
Sarma, Raghava; Prajapati, Jayesh; Raheem, Asif; Thakkar, Kamlesh; Kothari, Shivani; Thakkar, Ashok
2015-08-01
The main culprit in first-generation drug eluting stents is 'durable' polymer, whose continuous presence may impair arterial healing and ultimately have a negative impact on late outcomes. The main enigma behind the biodegradable polymer usage is its degradation after elution of drug. This reduces adverse events in unselected patients with complex coronary artery lesions treated with biodegradable polymer coated sirolimus-eluting stents. The aim of the INDOLIMUS-G Registry was to evaluate safety and efficacy of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stents in large cohorts of unselected patients with complex coronary artery lesions. It is a multi-centre, non-randomized retrospective registry with a clear aim of evaluating safety and efficacy of the Indolimus sirolimus-eluting stents in consecutive patients enrolled between April 2012 and May 2014. The primary end-point of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR) and stent thrombosis (ST) at the end of follow-up. Clinical follow-up were scheduled at the end of 30-days, 6-months, and 9-months period. The mean age of enrolled patients was 52.6 ± 11.0 years. A total of 1137 lesions were intervened successfully with 1242 stents (1.09 ± 0.30 stent per lesion). The average stent length and diameter was 27.42 ± 9.01 mm and 3.12 ± 0.36 mm respectively. There were 740 (73.40%) male patients, indicating their high prevalence. Diabetes, hypertension and totally occluded lesions were found in 372 (36.90%), 408 (40.47%) and 170 (16.86%) patients, respectively. This showed that study also included high risk complex lesions and not ideal recruited lesions. The incidence of MACE at 30-days, 6-months and 9-months were 3 (0.30%), 18 (1.80%) and 22 (2.20%) respectively. At 9-months, TLR was found in 6 (0.50%) patients. There were 2 (0.20%) cases of ST, 10 (1.0%) cases of MI and 4 (0.40%) cases of cardiac death at 9-month follow-up. The lower incidence of MACE, TLR and ST at 9-month follow-up clearly delineates safety and efficacy of Indolimus SES in large cohorts of unselected patients with complex coronary lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaytsev, A.Y., E-mail: cir-auz@mail.ru; Stoyda, A.Y.; Smirnov, V.E.
2006-10-15
Purpose. Stenoses and thromboses of vessels feeding the vertebrobasilar territory can evoke serious disturbances including ischemic stroke. We present our experience of endovascular interventions for patients with signs of vertebrobasilar insufficiency (VBI) resulted from subclavian, vertebral and brachiocephalic arterial stenoses. Methods. Twenty-one patients (10 men) aged from 35 to 84 years (mean 64.3 years) with symptoms compatible with VBI underwent balloon angioplasty and stenting of subclavian (SA), innominate (IA) and vertebral (VA) arteries. Procedures were done by radiologists experienced in systematic stenting of the lesions. VBI was manifested by persistent signs in 15 patients, and by transitory ischemic attacks inmore » the posterior circulatory territory in 4 (19%). Two patients (10%) experienced ischemic strokes (in the vertebrobasilar circulation in both cases). In 3 patients (14%) VBI was accompanied by upper limb vascular insufficiency symptoms. All cases were resistant to medical treatment. A neurologist assessed complaints, initial VBI signs and their alteration after intervention in all patients. Outcomes were measured with the 5-point scale suggested by Malek et al.: (1) excellent result (asymptomatic, no neurologic deficits and no symptoms of vertebrobasilar ischemia); (2) good (no neurologic deficits, at most one transient episode of vertebrobasilar ischemia over a period of 3 months after treatment); (3) fair (minimal neurologic deficit and at most one transient episode per month of vertebrobasilar ischemia); (4) poor (no improvement compared with neurologic status before treatment and/or persistent symptoms of vertebrobasilar ischemia); (5) death (regardless of cause). Endovascular treatment was performed for SA stenosis in 15 patients, for SA occlusion in 2, for IA stenosis in 2, and for VA stenosis in 2. There were 15 cases of atherosclerosis, 2 of aortoarteritis, 4 of proximal SA kinking. SA and IA stenoses ranged from 60% to 100% (mean 74.5%), VA stenoses were 90% in both cases. Results. Initial technical success was achieved in 96% of cases. There were no postprocedural complications or deaths. During 6-36 months (mean 21.3 months) of follow-up all patients showed improvement in VBI symptoms or upper limb ischemia. Within 36 months after the procedure outcomes were estimated as excellent and good in 13 patients (76%) and poor in 2 (12%), the last being attributed to atherosclerosis progression in other vascular areas. Restenosis in the stented area has developed in 1 patient (6%). Conclusions. Balloon angioplasty and stenting of extracranial vertebrobasilar arterial stenoses appeared to be effective in endovascular treatment of medically resistant VBI. Further investigations are required to clarify the role of subclavian artery kinking in VBI development and indications for various methods of its correction.« less
Sabbah, Mahmoud; Kadota, Kazushige; Fuku, Yasushi; Mitsudo, Kazuaki
2015-01-01
Stent malapposition and overhanging stent struts in front of the side branch (SB) ostium are not uncommon following bifurcation stenting that might lead to stent thrombosis. We herein present 2 cases, in which optical frequency domain imaging and intravascular ultrasound effectively revealed stent malapposition and overhanging struts inside the ostium of the SB following left main coronary artery stenting. Therefore, we introduced a novel technique for rectification of these incidental findings by selective SB re-wiring through the most distal stent cell with the adjunctive help of a double lumen microcatheter. PMID:27122906
Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention
Kwon, Chang-Il; Lehman, Glen A.
2016-01-01
Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422
Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.
Rafighdust, Abbasali; Eshraghi, Ali
2015-10-27
The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.
McGrath, Emmet E; Warriner, David; Anderson, Paul
2012-02-01
To describe a 10-year experience of inserting Ultraflex™ self-expanding metal stents (SEMS) under sedation using flexible bronchoscopy for the treatment of malignant tracheobronchial stenosis in a tertiary referral centre. Medical notes were retrospectively reviewed for all patients who underwent SEMS insertion between 1999 and 2009. A data analysis of 68 patients who had Ultraflex™ SEMS inserted under sedation was completed. Thirty three males and 35 females with a mean age of 67.9 years (range 35-94) presented with features including dyspnea/respiratory distress (39 patients), stridor (16 patients) and hemoptysis/dyspnea (13 patients). Etiology of stenosis included lung cancer (46 patients) esophageal cancer (14 patients) and other malignancies (8 patients). Mean dose of midazolam administered was 5mg (range 0-10mg). The trachea was the most common site of stent insertion followed by the right and left main bronchus, respectively. Adjuvant laser therapy was applied at some stage in 31% of all cases, and chemotherapy and/or radiotherapy was administered to at least 64% of patients with malignant disease. Hemoptysis and stent migration were the most frequent complications (5 and 4 patients, respectively). The mean survival time of stented non-small cell lung cancer (NSCLC) patients was 214 days (range 5-1233) and that of esophageal malignancy was 70 days (range 12-249). Mean pack-year history of individuals with lung cancer requiring stent insertion was 37 (range 2-100). Ultraflex stents offer a safe and effective therapy for patients who are inoperable or unresectable that otherwise would have no alternative therapy. It has an immediate beneficial effect upon patients, not only through symptom relief but, in some, through prolongation of life. Survival data is no worse than other studies using different varieties of stents and insertion techniques indicating its longer-term efficacy. Moreover, this report highlights the feasibility of performing this procedure successfully in a respiratory unit, without the need for general anesthesia. Copyright © 2011 SEPAR. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurre, Wiebke, E-mail: wiebke.kurre@gmx.de; Aguilar-Pérez, Marta; Fischer, Sebastian
PurposeThin-strut, flexible DES are suitable for intracranial stenting and may improve long-term vessel patency. The purpose of this study was to report our experience with two new-generation DES for the treatment of intracranial atherosclerotic disease.Patients and MethodsWe retrospectively reviewed all patients treated with Taxus Element™ or Resolute Integrity™ stent for an intracranial atherosclerotic stenosis between March 2011 and August 2013. Technical success was defined as the ability to deploy the device at the desired location and reduce the degree of stenosis below 50 %. All procedure-related strokes were recorded. Control angiography was scheduled after 6 weeks, 3, 6, and 12 months and yearlymore » thereafter. A luminal narrowing ≥50 % was regarded as a restenosis. Stroke recurrence in the territory of the treated artery was reported.ResultsIn the defined period we treated 101 patients harboring 117 intracranial stenoses. The procedure was successful in 100 (85.5 %) lesions. Procedure-related strokes occurred in 10 (9.9 %) patients with a permanent morbidity in 3 (3.0 %). Follow-up angiography was available for 83 of 100 (83.0 %) successfully treated lesions with an average of 355 days (IQR 153–482 days). Three (3.6 %) asymptomatic restenoses were detected. All occurred after treatment with Resolute Integrity™, none after Taxus Element™ (p = 0.059). New strokes in the territory of the treated artery were encountered in 2 (2.6 %) occasions.ConclusionThin-strut DES improve long-term patency and reduce the risk of subsequent stroke. Differences between devices may exist. Feasibility is comparable to bare-metal balloon-mounted stents and procedure-related strokes occurred within the expected range.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, Ji Hoon; Angle, John F.; Park, Auh Whan
Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8)more » or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.« less
Spira, Daniel; Wiskirchen, Jakub; Lauer, Ulrich; Ketelsen, Dominik; Nikolaou, Konstantin; Wiesinger, Benjamin
2016-07-01
The transjugular intrahepatic portosystemic stent-shunt (TIPSS) builds a shortcut between the portal vein and a liver vein, and represents a sophisticated alternative to open surgery in the management of portal hypertension or its complications. To describe clinical experiences with a low-profile nitinol stent system in TIPSS creation, and to assess primary and long-term success. Twenty-six patients (5 females, 21 males; mean age 54.6 years) were treated using a low-profile 6F self-expanding sinus-SuperFlex-Visual stent system. The indication for TIPSS creation was refractory bleeding in 9 of the 26 patients, refractory ascites in 18 patients, and acute thrombosis of the portal vein confluence in one patient. Portosystemic pressure gradients before and after TIPSS, periprocedural and long-term complications, and the time to orthotopic liver transplantation (OLT) or death were recorded. The portosystemic pressure gradient was significantly reduced, from 20.9 ± 6.3 mmHg before to 8.2 ± 2.3 mmHg after TIPSS creation (P < 0.001). Procedure-related complications included acute tract occlusion (n = 2), liver hematoma (n = 1), hepatic encephalopathy (n = 1), and cardiac failure (n = 1). Three of the 26 patients had late-onset TIPSS occlusion (at 12, 12, and 39 months after TIPSS creation). Three patients died within one week after the procedure due to their poor general condition (multiorgan failure, acute respiratory distress syndrome, necrotizing pancreatitis, and aspiration pneumonia). Another four patients succumbed to their underlying advanced liver disease within one year after TIPSS insertion. Seven patients underwent OLT at a mean time of 9.4 months after TIPSS creation. The sinus-SuperFlex-Visual stent system can be safely deployed as a TIPSS device. The pressure gradient reduction was clinically sufficient to treat the patients' symptoms, and periprocedural complications were due to the TIPSS procedure per se rather than to the particular stent system employed in this study.
Del Junco, Michael; Yoon, Renai; Okhunov, Zhamshid; Abedi, Garen; Hwang, Christina; Dolan, Benjamin; Landman, Jaime
2015-09-01
We compared the flow characteristics of novel three-dimensional (3D) printed ureteral stents with four conventional double-pigtail stents in an ex vivo porcine model. In six ex vivo porcine urinary systems with kidneys and ureters intact, we deployed a 5F occlusion catheter in an interpolar calix. We tested each system with antegrade irrigation with a 0.9% saline bag placed 35 cm above the renal pelvis. We evaluated four standard stents (6F Universa® Soft, 7F Percuflex,™ 7/10F Applied Endopyelotomy, 8.5F Filiform Double Pigtail) and compared them with a 9F 3D printed prototype stent. For each stent, we measured the total, extraluminal, and intraluminal flow rates. The mean total flow rates for 3D printed stents were significantly higher than the 6F, 7F, and 7/10F stents (P<0.05). No significant difference was seen in the total flow rate for the 3D printed stent and the 8.5F stent. The mean extraluminal flow rates for the 3D stents were similar to those of 7F stents, but significantly lower than 6F stents (P<0.001) and 8.5F stents (P<0.05) and higher than 7/10F stents (P<0.001). The mean intraluminal flow rates for the 3D printed stents were significantly higher than the 6F, 7F, 7/10F, and 8.5F stents (P<0.05). In this pilot study, 3D printed stents manifested a mean total flow rate comparable to the flow rates of contemporary stents. Continued advances in technology and material may permit functionally feasible 3D printed ureteral stents.
A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.
Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K
2012-06-01
Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.
Ronald, James; Davis, Bradley; Guevara, Carlos J; Pabon-Ramos, Waleska M; Smith, Tony P; Kim, Charles Y
2017-05-15
To report patency rates for stent deployment for treatment of in-stent stenosis of the central veins of the chest in hemodialysis patients. A retrospective analysis was performed on 29 patients who underwent 35 secondary percutaneous transluminal stent (PTS) deployments for in-stent stenosis within the central veins that were refractory to angioplasty and ipsilateral to a functioning hemodialysis access (in-stent PTS group). For comparison, patency data were acquired for 47 patients who underwent 78 successful percutaneous transluminal angioplasty (PTA) procedures for in-stent stenosis (in-stent PTA group) and 55 patients who underwent 55 stent deployments within native central vein stenosis refractory to angioplasty (native vein PTS group). The 3-, 6-, and 12-month primary lesion patency for the in-stent PTS group was 73%, 57%, and 32%, respectively. The 3-, 6-, and 12-month primary patency for the in-stent PTA group was 70%, 38%, and 17% and for the native vein PTS group was 78%, 57%, and 26%, which were similar to the in-stent PTS group (p = 0.20 and 0.41, respectively). The 3-, 6-, and 12-month secondary access patency was 91%, 73%, and 65% for the in-stent PTS group. Sub-analysis of the in-stent PTS group revealed no difference in primary (p = 0.93) or secondary patency rates (p = 0.27) of bare metal stents (n = 23) compared with stent grafts (n = 12). Stent deployment for central vein in-stent stenosis refractory to angioplasty was associated with reasonable patency rates, which were similar to in-stent PTA and native vein PTS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Grenacher, L.; Stampfl, U.
The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 {mu}m). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury,more » vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 {mu}m. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 {mu}m and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.« less
Wen, Wei; Ma, Li-Mei; He, Wei; Tang, Xiao-Wei; Zhang, Yin; Wang, Xiang; Liu, Li; Fan, Zhi-Ning
2016-02-01
One of the major limitations of biliary stents is the stent occlusion, which is closely related to the over-growth of bacteria. This study aimed to evaluate the feasibility of a novel silver-nanoparticle-coated polyurethane (Ag/PU) stent in bacterial cholangitis model in swine. Ag/PU was designed by coating silver nanoparticles on polyurethane (PU) stent. Twenty-four healthy pigs with bacterial cholangitis using Ag/PU and PU stents were randomly divided into an Ag/PU stent group (n=12) and a PU stent group (n=12), respectively. The stents were inserted by standard endoscopic retrograde cholangiopancreatography. Laboratory assay was performed for white blood cell (WBC) count, alanine aminotransferase (ALT), interleukin-1beta (IL-1beta), tumor necrosis factor-alpha (TNF-alpha) at baseline time, 8 hours, 1, 2, 3, and 7 days after stent placements. The segment of bile duct containing the stent was examined histologically ex vivo. Implanted biliary stents were examined by a scan electron microscope. The amount of silver release was also measured in vitro. The number of inflammatory cells and level of ALT, IL-1beta and TNF-alpha were significantly lower in the Ag/PU stent group than in the PU stent group. Hyperplasia of the mucosa was more severe in the PU stent group than in the Ag/PU stent group. In contrast to the biofilm of bacteria on the PU stent, fewer bacteria adhered to the Ag/PU stent. PU biliary stents modified with silver nanoparticles are able to alleviate the inflammation of pigs with bacterial cholangitis. Silver-nanoparticle-coated stents are resistant to bacterial adhesion.
Lettau, Michael; Kotter, Elmar; Bendszus, Martin; Hähnel, Stefan
2014-10-01
CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong
2017-10-18
Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.
Radial force measurement of endovascular stents: Influence of stent design and diameter.
Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko
2016-04-01
Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P < 0.01). The radial force of the thoracic stents was greater than that of all three endovascular stents (P < 0.01). Differences in radial force depend on types of stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.
Gupta, Rajesh; Reddy, D Nageshwar
2011-09-01
Endoscopic stenting is an effective treatment option in the management of both benign biliary strictures and pancreatic ductal strictures. Plastic stents and self-expandable metal stents have been used with variable success for the management of both benign biliary strictures and pancreatic ductal strictures caused by chronic pancreatitis. Fully covered self-expandable metal stents of improved design represent a major technological advance which has added to the endoscopic armamentarium. Both multiple plastic stents and covered self-expandable metal stents have shown promising results. However, data to support the use of self-expandable metal stents over multiple plastic stents or vice versa are still lacking.
Zhang, Qi; Wang, Xiao Long; Liao, Min Lei; Hu, Jian; Yang, Zhen Kun; Ding, Feng Hua; Zhang, Jian Sheng; Du, Run; Zhu, Tian Qi; Shen, Wei Feng; Zhang, Rui Yan
2015-03-01
Patients are at risk of developing periprocedural myonecrosis after percutaneous coronary intervention (PCI). We investigated whether the use of the platelet glycoprotein (GP) IIb/IIIa receptor inhibitor tirofiban could reduce periprocedural myocardial infarction (PMI) in patients with stable coronary artery disease undergoing elective PCI with overlapping stent implantation for long lesions. A total of 748 stable angina patients with long lesions (≥ 40 mm in length) treated with overlapping stent implantation were randomly assigned to receive tirofiban (tirofiban group; n = 373) or conventional therapy (control group; n = 375). Intravenous tirofiban was initiated before PCI and maintained for 12 hr after the procedure. The primary endpoint was PMI, defined as an elevation in CK-MB > 3 times the upper limit of normal 12 hr after the index procedure. The secondary endpoint was major adverse cardiac events (MACE), including cardiac death, target vessel revascularization, and recurrent MI (re-MI), at one-year of clinical follow-up. The safety end-points included Thrombolysis in Myocardial Infarction (TIMI) major bleeding and stent thrombosis. Despite comparable angiographic and procedural characteristics, in the intention-to-treatment analysis, the primary endpoint was significantly reduced in the tirofiban group (4.0% vs. 11.5%, P < 0.001). Multivariate analysis revealed that the adjunctive use of tirofiban was the only negative predictor of PMI (OR 0.41, 95% CI 0.28-0.81, P < 0.01). At one-year of clinical follow-up, the overall occurrence of MACE was significantly lower in the tirofiban group (13.4% vs. 22.7%, P = 0.001). The rate of TIMI major bleeding and stent thrombosis did not differ significantly between the two groups. Our results show that the adjunctive use of tirofiban reduces the occurrence of PMI and MACE at one year in stable coronary artery disease patients undergoing elective PCI for long lesions with overlapping stent implantation. © 2015 Wiley Periodicals, Inc.
Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S; Prothmann, Sascha
2016-01-01
Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.
Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S.; Prothmann, Sascha
2016-01-01
Background Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. Methods 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Results Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Conclusion Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome. PMID:27073908
Shammas, Nicolas W; Aasen, Nicole; Bailey, Lynn; Budrewicz, Jay; Farago, Trent; Jarvis, Gary
2015-08-01
To determine the number of runs with blades up (BU) using the JetStream Navitus to achieving optimal debulking in a porcine model of femoropopliteal artery in-stent restenosis (ISR). In this porcine model, 8 limbs were implanted with overlapping nitinol self-expanding stents. ISR was treated initially with 2 blades-down (BD) runs followed by 4 BU runs (BU1 to BU4). Quantitative vascular angiography (QVA) was performed at baseline, after 2 BD runs, and after each BU run. Plaque surface area and percent stenosis within the treated stented segment were measured. Intravascular ultrasound (IVUS) was used to measure minimum lumen area (MLA) and determine IVUS-derived plaque surface area. QVA showed that plaque surface area was significantly reduced between baseline (83.9%±14.8%) and 2 BD (67.7%±17.0%, p=0.005) and BU1 (55.4%±9.0%, p=0.005) runs, and between BU1 and BU2 runs (50.7%±9.7%, p<0.05). Percent stenosis behaved similarly with no further reduction after BU2. There were no further reductions in plaque surface area or percent stenosis with BU 3 and 4 runs (p=0.10). Similarly, IVUS (24 lesions) confirmed optimal results with BU2 runs and no additional gain in MLA or reduction in plaque surface area with BU3 and 4. IVUS confirmed no orbital cutting with JetStream Navitus. There were no stent strut discontinuities on high-resolution radiographs following atherectomy. JetStream Navitus achieved optimal tissue debulking after 2 BD and 2 BU runs with no further statistical gain in debulking after the BU2 run. Operators treating ISR with JetStream Navitus may be advised to limit their debulking to 2 BD and 2 BU runs to achieve optimal debulking. © The Author(s) 2015.
Hong, Young Joon; Jeong, Myung Ho; Abizaid, Alexander; Banning, Adrian; Bartorelli, Antonio; Dzavik, Vladimir; Ellis, Stephen G; Gao, Runlin; Holmes, David R; Legrand, Victor; Neumann, Franz-Josef; Spaulding, Christian; Worthley, Stephen; Urban, Philip
2011-09-01
The aim of this study was to identify the worldwide practice of Cypher Select (Cordis Corporation, Bridgewater, New Jersey) or Cypher Select Plus sirolimus-eluting stent (SES) in patients 80 years of age (octogenarian) and to identify clinical outcomes in this patient population. The use of drug-eluting stents in elderly patients may have different features compared with younger patients. Between 2006 and 2008, 15,147 patients from 320 hospitals in 56 countries were enrolled in a registry. Initial implantation and follow-up outcome information obtained at 1-year follow-up in 675 octogenarian patients were compared with those in 14,472 nonoctogenarian patients. Octogenarians had significantly more comorbidities and had higher Charlson comorbidity index scores (1.5 ± 1.6 vs. 1.0 ± 1.3, p < 0.001). Rates of cardiac death (3.3% vs. 0.9%, p < 0.001), myocardial infarction (2.3% vs. 1.9%, p = 0.021), and definite or probable stent thrombosis (2.3% vs. 0.9%, p = 0.0002), and major bleeding (2.0% vs. 0.9%, p = 0.015) were significantly higher in octogenarians at 1 year; however, there was no significant difference in the rate of target lesion revascularization between the 2 groups (3.2% vs. 2.2%, p = 0.12). In octogenarians, a high Charlson comorbidity index was an independent predictor of death and stent thrombosis up to 360 days from the index procedure (hazard ratio: 1.3, 95% confidence interval: 1.1 to 1.5, p < 0.001, and hazard ratio: 1.5, 95% confidence interval: 1.3 to 1.8, p < 0.001, respectively). Stenting with SES may be an effective therapeutic option in elderly patients, with acceptable rates of complications and a very low rate of repeat revascularization as demonstrated by this e-SELECT (A Multi-Center Post-Market Surveillance Registry) subgroup analysis. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Riaz, Usman; Rakesh, Leela; Shabib, Ishraq; Haider, Waseem
2018-06-05
The issue of long-term incompatible interactions associated with the permanent implants can be eliminated by using various biodegradable metal implants. The recent research is focusing on the use of degradable stents to restore most of the hindrances of capillaries, and coronary arteries by supplying instant blood flow with constant mechanical and structural support. However, internal endothelialization and infection due to the corrosion of implanted stents are not easy to diagnose in the long run. In the recent past, magnesium (Mg) has been widely investigated for the cardiovascular stent applications. Here we made an attempt to understand the biodegradation process of Mg alloy stent by studying the degradation of Mg alloy AZ31 (3 wt% Aluminum, 1 wt% Zn) powder at various time-intervals in simulated blood fluid using the Rheological methods. The degradability of the Mg stent in the arteries affects the stress-strain properties of blood plasma and the subsequent flow conditions. Blood and plasma viscosities alter due to the degradation of Mg resulting from the stress-strain experienced in the blood vessels, in which the stent is inserted. Here our objective was to explore the influence of Mg degradation on the blood plasma viscosity by studying the viscoelastic properties. In this work, the effect of dissolution of Mg alloy AZ31 on the rheological properties of Phosphate Buffer Saline (PBS) at various time intervals have been investigated. The viscosity of the PBS-AZ31 solution increased with the dissolution of both slurries and percolated clear solution. The only exception was day-7 of the percolated clear solution, where viscosity was decreased showing a reduction in viscosity at initial stages of dissolution. The frequency sweep showed the tendency of the PBS-AZ31 gelation up to 100 rad/s frequency. Copyright © 2018 Elsevier Ltd. All rights reserved.
Drug eluting stents and modern stent technologies for in-stent restenosis.
Werner, Martin
2017-08-01
The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.
MRI Artifacts of a Metallic Stent Derived From a Human Aorta Specimen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soto, M. E.; Flores, P.; Marrufo, O.
Magnetic resonance imaging has proved to be a useful technique to get images of the whole body. However, the presence of ferromagnetic material can cause susceptibility artifacts, which result from microscopic gradients that occur near the boundaries between areas displaying different magnetic susceptibility. These gradients cause dephasing of spins and frequency shifts in the surrounding tissues. Intravoxel dephasing and spatial mis-registration can degrade image quality. An aorta with a metallic stent was preserved in formaldehyde at 10% inside acrylic cylinders and used to obtain MR images. We tested pulsed spin echo and gradient echo sequences to improve image quality. Allmore » experiments were performed on a 7T/21 cm Varian system (Varian, Inc, Palo Alto, CA) equipped with Direct Drive technology and a 16-rung birdcage coil transceiver. The presence of metallic stents produces a lack of signal that might give falsely reassuring appearances within the vessel lumen.« less
Percutaneous Femoropopliteal Recanalization Using a Completely Transpedal/Transtibial Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, Timothy W.I., E-mail: timothy.clark@uphs.upenn.edu; Watts, Micah M.; Kwan, Tak W.
PurposeTo report preliminary experience with femoropopliteal revascularization using a completely transpedal/transtibial approach.Materials and MethodsThree patients with Rutherford 3–4 disease underwent revascularization of TASC C/D lesions using a pedal/tibial artery as the only site of arterial access.ResultsOne patient with a chronic superficial femoral artery occlusion had continuity achieved to the common femoral artery using a dedicated reentry device and stenting; in a second patient, an occluded popliteal artery stent was successfully revised with an endograft; and in a third patient with morbid obesity, a chronic SFA occlusion was successfully stented. All patients experienced complete resolution of presenting symptoms; no puncture sitemore » complications were seen.ConclusionsUse of a pedal/tibial approach as the sole site of arterial access may become an important access technique for femoropopliteal revascularization when patients have limited femoral access options.« less
Fatigue and In Vivo Validation of a Peritoneum-Lined Self-Expanding Nitinol Stent-Graft
Bastijanic, Jennifer M.; Etscheidt, Jordan; Sattiraju, Mallika; Bonsignore, Craig; Kopchok, George; White, Rodney; Sarac, Timur P.
2014-01-01
Purpose To assess the fatigue and in vivo performance of a new stent-graft incorporating bovine peritoneum lining that is designed for application in peripheral vascular occlusive disease. Methods Bovine peritoneum-lined stent-grafts were subjected to accelerated in vitro pulsatile fatigue and axial/torsional fatigue testing designed to simulate 10 years of physiological strain on the devices. At specified times the devices were evaluated for stent fracture, suture failure, or tissue tearing. Seven dogs underwent bilateral common iliac artery (CIA) balloon angioplasty injury with unilateral placement of the peritoneum-lined stent-graft. Angiography and intravascular ultrasound were performed prior to treatment, after treatment, and prior to sacrifice at 30 days. Vessels were perfusion fixed and histologically evaluated at 5 regions: above stent, proximal stent, mid stent, distal stent, and below stent. Results No evidence of stent, suture, or tissue failure was present during or after pulsatile and axial/torsional fatigue testing. At 30±0.3 days after implantation, all vessels were patent. The average lumen area at explantation across stented vessels was 25.45 mm2. Lumen areas tended to be reduced above (23.57 mm2) and below (24.17 mm2) the stent. Lumen areas were consistent across stented regions at explantation (proximal stent 27.80 mm2, mid stent 25.88 mm2, and distal stent 25.81 mm2). The mean neointimal area in peritoneum-lined stents was 2.02±1.52 mm2, with a neointima:media ratio of 1.03±0.50. These values were significantly lower in the above and below stent areas than in the stented regions, but there was no difference in either measure within the proximal, mid, or distal stent. Conclusion The custom-designed peritoneum-lined stent-graft is promising for clinical peripheral applications due to its ability to resist relevant long-term physiological stresses and outstanding short-term patency rates in canine implantations. PMID:25290804
Polymeric coating of surface modified nitinol stent with POSS-nanocomposite polymer.
Bakhshi, Raheleh; Darbyshire, Arnold; Evans, James Eaton; You, Zhong; Lu, Jian; Seifalian, Alexander M
2011-08-01
Stent angioplasty is a successful treatment for arterial occlusion, particularly in coronary artery disease. The clinical communities were enthusiastic about the use of drug-eluting stents; however, these stents have a tendency to be a contributory factor towards late stage thrombosis, leading to mortality in a significant number of patients per year. This work presents an innovative approach in self-expanding coronary stents preparation. We developed a new nanocomposite polymer based on polyhedral oligomeric silsesquioxanes (POSS) and poly(carbonate-urea)urethane (PCU), which is an antithrombogenic and a non-biodegradable polymer with in situ endothelialization properties. The aim of this work is to coat a NiTi stent alloy with POSS-PCU. In prolonged applications in the human body, the corrosion of the NiTi alloy can result in the release of deleterious ions which leads to unwanted biological reactions. Coating the nitinol (NiTi) surface with POSS-PCU can enhance surface resistance and improve biocompatibility. Electrohydrodynamic spraying was used as the polymer deposition process and thus a few experiments were carried out to compare this process with casting. Prior to deposition the NiTi has been surface modified. The peel strength of the deposit was studied before and after degradation of the coating. It is shown that the surface modification enhances the peel strength by 300%. It is also indicated how the adhesion strength of the POSS-PCU coating changes post-exposure to physiological solutions comprised of hydrolytic, oxidative, peroxidative and biological media. This part of the study shows that the modified NiTi presents far greater resistance to decay in peel strength compared to the non-modified NiTi. Copyright © 2011 Elsevier B.V. All rights reserved.