Sample records for stent system initial

  1. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.

    PubMed

    Kogure, Hirofumi; Isayama, Hiroyuki; Nakai, Yousuke; Tsujino, Takeshi; Matsubara, Saburo; Yashima, Yoko; Ito, Yukiko; Hamada, Tsuyoshi; Takahara, Naminatsu; Miyabayashi, Koji; Mizuno, Suguru; Mohri, Dai; Kawakubo, Kazumichi; Sasaki, Takashi; Yamamoto, Natsuyo; Hirano, Kenji; Sasahira, Naoki; Tada, Minoru; Koike, Kazuhiko

    2014-01-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement in a stent-in-stent method for malignant hilar biliary obstruction is technically challenging. Technical difficulties in the initial placement and reinterventions for stent occlusion are disadvantages inherent to this stent-in-stent method. We previously reported the feasibility of Niti-S large cell D-type biliary stents (LCD). This multicenter prospective consecutive study evaluated the efficacy of bilateral SEMS placement using modified LCD with large and uniform cells, a slimmer delivery system and high radial force. From July 2010 to June 2011, 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent endoscopic bilateral placement of modified LCD in a stent-in-stent method at three tertiary hospitals. Ten patients had gallbladder cancer, eight had cholangiocarcinoma, four had lymph node metastasis, two had intrahepatic cholangiocarcinoma, and two had liver metastasis. Single-session and final technical success rate was 96% and 100%, respectively. Functional success rate was 89%. Stent occlusion occurred in 11 patients (42%) because of sludge (n = 7) or tumor ingrowth (n = 4). Endoscopic bilateral reintervention was technically easy and successful: six patients had stent clearance by balloon sweeping and five had plastic stent placement. According to Kaplan-Meier analysis, median survival and stent patency were 220 days and 157 days, respectively. Modified LCD achieved a high technical success rate both in the initial stent-in-stent placement and in bilateral reinterventions in patients with malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  2. Systemic rapamycin to prevent in-stent stenosis in peripheral pulmonary arterial disease: early clinical experience.

    PubMed

    Hallbergson, Anna; Esch, Jesse J; Tran, Trang X; Lock, James E; Marshall, Audrey C

    2016-10-01

    We have taken a novel approach using oral rapamycin - sirolimus - as a medical adjunct to percutaneous therapy in patients with in-stent stenosis and high risk of right ventricular failure. Peripheral pulmonary artery stenosis can result in right ventricular hypertension, dysfunction, and death. Percutaneous pulmonary artery angioplasty and stent placement acutely relieve obstructions, but patients frequently require re-interventions due to re-stenosis. In patients with tetralogy of Fallot or arteriopathy, the problem of in-stent stenosis contributes to the rapidly recurrent disease. Rapamycin was administered to 10 patients (1.5-18 years) with peripheral pulmonary stenosis and in-stent stenosis and either right ventricular hypertension, pulmonary blood flow maldistribution, or segmental pulmonary hypertension. Treatment was initiated around the time of catheterisation and continued for 1-3 months. Potential side-effects were monitored by clinical review and blood tests. Target serum rapamycin level (6-10 ng/ml) was accomplished in all patients; eight of the nine patients who returned for clinically indicated catheterisations demonstrated reduction in in-stent stenosis, and eight of the 10 patients experienced no significant side-effects. Among all, one patient developed diarrhoea requiring drug discontinuation, and one patient experienced gastrointestinal bleeding while on therapy that was likely due to an indwelling feeding tube and this patient tolerated rapamycin well following tube removal. Our initial clinical experience supports that patients with peripheral pulmonary artery stenosis can be safely treated with rapamycin. Systemic rapamycin may provide a novel medical approach to reduce in-stent stenosis.

  3. Recent Advances in Drug Eluting Stents

    PubMed Central

    Puranik, Amey S.; Dawson, Eileen R.; Peppas, Nicholas A.

    2013-01-01

    One of the most common medical interventions to reopen an occluded vessel is the implantation of a coronary stent. While this method of treatment is effective initially, restenosis, or the re-narrowing of the artery frequently occurs largely due to neointimal hyperplasia of smooth muscle cells. Drug eluting stents were developed in order to provide local, site-specific, controlled release of drugs that can inhibit neointima formation. By implementing a controlled release delivery system it may be possible to control the time release of the pharmacological factors and thus be able to bypass some of the critical events associated with stent hyperplasia and prevent the need for subsequent intervention. However, since the advent of first-generation drug eluting stents, long-term adverse effects have raised concerns regarding their safety. These limitations in safety and efficacy have triggered considerable research in developing biodegradable stents and more potent drug delivery systems. In this review, we shed light on the current state-of-the-art in drug eluting stents, problems related to them and highlight some of the ongoing research in this area. PMID:23117022

  4. Preventing the forgotten ureteral stent: implementation of a web-based stent registry with automatic recall application.

    PubMed

    Lynch, Mark F; Ghani, Khurshid R; Frost, Ian; Anson, Ken M

    2007-09-01

    To describe and analyze a unique computerized system that tracks ureteral stents and automatically sends a notice by e-mail to clinical staff if a stent becomes overdue for removal. We have developed an electronic stent register (ESR) and stent extraction reminder facility (SERF) located within our hospital computer network. After stent insertion, a stent "episode" is created in the ESR with a mandatory maximal stent life (MSL). The SERF interrogates the ESR on a daily basis and identifies stents that have breached its MSL, generating daily e-mail notices to personnel until the stent is removed and the ESR updated. The episode data capture initially employing manual entry was changed to barcode technology acquisition. We analyzed the success of patient recall and conducted a prospective, blinded review to determine the success of the data acquisition. A total of 293 episodes were created within 2.4 years. Of the 241 (86%) episodes that were closed, 123 (51%) went beyond the MSL. The mean delay from designated MSL to stent removal was 20.89 days (SD 19.71). In the 7 months before barcode data acquisition, 43 of 71 stents were entered into the ESR (data capture rate 61%). In the 7 months after barcode data acquisition, 52 of 60 stents were entered (data capture rate 87%; P = 0.0009). The results of our study have shown the ESR and SERF to be robust and valuable tools for the treatment of patients with ureteral stents. Barcode acquisition significantly improved the stent insertion capture rate. This system ensures improved patient safety with an element of protection from potential litigation.

  5. Antegrade Ureteral Stenting is a Good Alternative for the Retrograde Approach.

    PubMed

    van der Meer, Rutger W; Weltings, Saskia; van Erkel, Arian R; Roshani, Hossain; Elzevier, Henk W; van Dijk, Lukas C; van Overhagen, Hans

    2017-07-01

    Double J (JJ) stents for treating obstructive ureteral pathology are generally inserted through a retrograde route with cystoscopic guidance. Antegrade percutaneous insertion using fluoroscopy can be performed alternatively but is less known. Indications, success rate and complications of antegrade ureteral stenting were evaluated. Data of consecutive patients in which antegrade ureteral stenting was performed were retrospectively analysed using the radiology information system and patient records. Patient characteristics, details of the antegrade JJ stent insertion procedure and registered complications were collected. Furthermore, it was investigated if prior to the antegrade procedure a retrograde attempt for JJ stent insertion was performed. Total 130 attempts for antegrade JJ stent insertion were performed in 100 patients. A percutaneous nephrostomy catheter had already been placed in the majority of kidneys (n = 109) for initial treatment of hydronephrosis. Most prevelant indication for a JJ stent was obstructive ureteral pathology due to malignancy (n = 63). A JJ stent was successfully inserted in 125 of 130 procedures. In 21 cases, previous retrograde ureteral stenting had failed but, subsequent antegrade ureteral stenting was successful. There were 8 procedure related complications; 6 infections, 1 false tract and 1 malposition. Antegrade percutaneous insertion of a JJ stent is a good alternative for retrograde insertion.

  6. Natural stent in the management of post-intubation tracheal stenosis.

    PubMed

    Park, Hye Yun; Kim, Hojoong; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung

    2009-05-01

    The treatment choice for post-intubation tracheal stenosis (PITS) in patients for whom surgery is not initially feasible is bronchoscopic silicone stenting. A new silicone stent, called the Natural stent (N stent), was investigated for its clinical efficacy and safety in patients with PITS. A retrospective review was conducted of 32 patients with PITS who underwent N stenting between November 2001 and December 2006 and were followed for at least 12 months. Airway dilatation with combined modalities such as Nd:YAG laser, ballooning or bougienage was followed by N stent insertion. After intervention, all patients had symptomatic and spirometric improvement without immediate complications. Removal of the stent without re-stenosis was successful in 38% of the patients at a median time of 7 months after insertion. The stent could not be removed or needed reinsertion in 31% of patients, and 16% of patients underwent surgery after initial stabilization by stenting. Late complications were stent migration (34%), mucostasis (31%), granulation tissue formation (38%) and re-stenosis (40%). All patients tolerated the management of complications during a median follow up of 22 months. Bronchoscopic N stenting is an effective treatment for patients with PITS in whom surgery is not feasible on initial presentation. Further stent development is necessary to reduce the late complication rate.

  7. Antegrade Ureteral Stenting is a Good Alternative for the Retrograde Approach

    PubMed Central

    van der Meer, Rutger W.; Weltings, Saskia; van Erkel, Arian R.; Roshani, Hossain; Elzevier, Henk W.; van Dijk, Lukas C.; van Overhagen, Hans

    2017-01-01

    Background/Aims Double J (JJ) stents for treating obstructive ureteral pathology are generally inserted through a retrograde route with cystoscopic guidance. Antegrade percutaneous insertion using fluoroscopy can be performed alternatively but is less known. Indications, success rate and complications of antegrade ureteral stenting were evaluated. Methods Data of consecutive patients in which antegrade ureteral stenting was performed were retrospectively analysed using the radiology information system and patient records. Patient characteristics, details of the antegrade JJ stent insertion procedure and registered complications were collected. Furthermore, it was investigated if prior to the antegrade procedure a retrograde attempt for JJ stent insertion was performed. Results Total 130 attempts for antegrade JJ stent insertion were performed in 100 patients. A percutaneous nephrostomy catheter had already been placed in the majority of kidneys (n = 109) for initial treatment of hydronephrosis. Most prevelant indication for a JJ stent was obstructive ureteral pathology due to malignancy (n = 63). A JJ stent was successfully inserted in 125 of 130 procedures. In 21 cases, previous retrograde ureteral stenting had failed but, subsequent antegrade ureteral stenting was successful. There were 8 procedure related complications; 6 infections, 1 false tract and 1 malposition. Conclusion Antegrade percutaneous insertion of a JJ stent is a good alternative for retrograde insertion. PMID:28785193

  8. Intracoronary beta-radiation for the treatment of patients at very high risk for recurrence of in-stent restenosis: a single center experience.

    PubMed

    Parenti, Dennis Zavalloni; Marsico, Federica; Tosi, Giovanni; Catalano, Gianpiero; Maiello, Luigi; Milone, Francesco; Carcagnì, Addolorata; Pron, Paolo Giay; Orecchia, Roberto; Presbitero, Patrizia

    2003-03-01

    Intracoronary brachytherapy has significantly reduced the recurrence of in-stent restenosis. The aim of this study was to evaluate the feasibility, safety and efficacy of intracoronary beta-radiation in patients at very high risk for recurrence of in-stent restenosis. We analyzed 42 patients with 50 lesions submitted to catheter-based beta-radiation (Beta-Cath System, Novoste Corporation, Norcross, GA, USA) for in-stent restenosis. Thirty-eight lesions were at the second restenosis, 8 at the third, and 4 at the fourth; a diffuse pattern was present in 78%. Balloon angioplasty was performed for 30 lesions (60%) and the cutting balloon technique for 20 (40%). In 12 lesions further 14 stents had to be deployed (28%). The delivery catheter was successfully positioned in 96% of the procedures. The mean dwell time was 179 +/- 50 s with a radiation dose ranging from 18.4 to 25.3 Gy, depending on the vessel size. A complete angiographic success without coronary dissection and without any additional stenting after radiation delivery was achieved in 86%. At follow-up (7.2 +/- 2.1 months), the overall restenosis rate was 30.4% (14 lesions). A recurrence was detected in 1/11 lesions with initial focal pattern and in 13/39 lesions with initial diffuse pattern. The restenosis rate was higher in patients in whom a geographic miss had occurred (p < 0.05 vs lesions without geographic miss) and in those in whom a new stent had been deployed (p < 0.05 vs lesions treated without a stent). Brachytherapy reduces the in-stent restenosis rate in patients who are at very high risk of recurrence. The restenosis pattern, geographic miss and new stent deployment seem to be negative prognostic factors for recurrence of restenosis.

  9. Internal stenting in malignant biliary obstruction.

    PubMed

    Cowling, M G; Adam, A N

    2001-03-01

    Internal stenting in inoperable malignant biliary obstruction plays an important role in patient management. Surgical bypass may still be undertaken where there is also duodenal obstruction, though the need for gastroenterostomy may be reduced with the increasing use of metallic stents for the relief of malignant gastric outlet obstruction. Stents may be placed endoscopically or percutaneously, though in most centers the endoscopic route is usually tried first, with the percutaneous route being reserved for endoscopic failures. Plastic and self-expanding metallic biliary stents are available, each with its own advantages and disadvantages. In general, longer periods of patency are observed with metallic stents, though they are more expensive. Plastic stents can be changed endoscopically relatively easily when they have blocked, and in practice it is common for plastic stents to be inserted via this route for initial biliary drainage. If there is prolonged survival thereafter, many workers insert a metallic stent in an attempt to reduce the number of interventions required. If the percutaneous route is being employed, the histologic diagnosis has been confirmed, and the malignancy is inoperable, our practice is to use a self-expanding metallic stent, as the delivery system is relatively small and subsequent occlusion less likely.

  10. Bilateral metal stents for hilar biliary obstruction using a 6Fr delivery system: outcomes following bilateral and side-by-side stent deployment.

    PubMed

    Law, Ryan; Baron, Todd H

    2013-09-01

    Controversy exists on optimal endoscopic management for palliation of malignant hilar obstruction, with advocates for metal "side-by-side" (SBS) and "stent-in-stent" (SIS) techniques. We sought to evaluate the technical feasibility, efficacy, and outcomes of bilateral biliary self-expanding metal stents (SEMS) for treatment of malignant hilar obstruction using a stent with a 6Fr delivery system. This was a single-center, retrospective review of all patients who underwent bilateral placement of Zilver® biliary SEMS for malignant hilar obstruction from January 2010 to August 2012. Patients underwent endoscopic retrograde cholangiopancreatography with placement of stents using either the SIS or SBS stent techniques. Twenty-four patients (19 men, mean age 63 years) underwent bilateral stenting for malignant hilar obstruction during the study period. Seventeen and seven patients underwent the SBS and SIS technique, respectively. Cholangiocarcinoma (n=14) was the most common cause of hilar obstruction. Initial technical success was achieved in 24/24 (100%) of patients; however, 12 (50%) patients required re-intervention during the study period (median 98 days). Comparison of the SBS and SIS groups revealed no statistical difference with respect to need for re-intervention (P=0.31), successful re-intervention (P=0.60), or procedural length (P=0.89). Use of bilateral Zilver® SEMS in either the SBS or SIS configuration is safe, technically feasible, and effective for drainage of malignant hilar obstruction; however, duration of stent patency and procedure-free survival remain variable.

  11. Monitoring the Wall Mechanics During Stent Deployment in a Vessel

    PubMed Central

    Steinert, Brian D.; Zhao, Shijia; Gu, Linxia

    2012-01-01

    Clinical trials have reported different restenosis rates for various stent designs1. It is speculated that stent-induced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis2-7. This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface8,9. As a mesh stent is deployed into a latex vessel with a random contrasting pattern sprayed or drawn on its outer surface, the surface strain is recorded at every instant of the deformation. The calculated strain distributions can then be used to understand the local lesion response, validate the computational models, and formulate hypotheses for further in vivo study. PMID:22588353

  12. Curve micromachining on the edges of nitinol biliary stent by ultrashort pulses laser

    NASA Astrophysics Data System (ADS)

    Hung, Chia-Hung; Chang, Fuh-Yu

    2017-05-01

    In this study, a curve micromaching process on the edges of nitinol biliary stent was proposed by a femtosecond laser system with a galvano-mirror scanner. Furthermore, the outer diameter of nitinol tube was 5.116 mm, its inner diameter was 4.648 mm, and its length was 100 mm. The initial fabricated results of nitinol biliary stent represented that the edges of nitinol biliary stent were steep and squared by femtosecond laser. However, the results also indicated that if the laser movement path was precisely programmed by utilizing the unique characteristic of Gaussian beam of femtosecond laser with aligning the edges of stent, the radius of edges enhanced significantly from 9 μm to 42.5 μm. As a result, the edges of nitinol biliary stent can be successfully fabricated from squared edges to rounded-shaped edges with precise dimension, clean surface morphology, and minimal heat-affected zone remained. Hence, the nitinol biliary stent, after femtosecond laser micromachining, would not need any further post-process to remove heat-affected zone and the squared edges.

  13. Fast Virtual Stenting with Active Contour Models in Intracranical Aneurysm

    PubMed Central

    Zhong, Jingru; Long, Yunling; Yan, Huagang; Meng, Qianqian; Zhao, Jing; Zhang, Ying; Yang, Xinjian; Li, Haiyun

    2016-01-01

    Intracranial stents are becoming increasingly a useful option in the treatment of intracranial aneurysms (IAs). Image simulation of the releasing stent configuration together with computational fluid dynamics (CFD) simulation prior to intervention will help surgeons optimize intervention scheme. This paper proposed a fast virtual stenting of IAs based on active contour model (ACM) which was able to virtually release stents within any patient-specific shaped vessel and aneurysm models built on real medical image data. In this method, an initial stent mesh was generated along the centerline of the parent artery without the need for registration between the stent contour and the vessel. Additionally, the diameter of the initial stent volumetric mesh was set to the maximum inscribed sphere diameter of the parent artery to improve the stenting accuracy and save computational cost. At last, a novel criterion for terminating virtual stent expanding that was based on the collision detection of the axis aligned bounding boxes was applied, making the stent expansion free of edge effect. The experiment results of the virtual stenting and the corresponding CFD simulations exhibited the efficacy and accuracy of the ACM based method, which are valuable to intervention scheme selection and therapy plan confirmation. PMID:26876026

  14. Endoscopically placed nitinol stents for pediatric tracheal obstruction.

    PubMed

    Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M

    2002-11-11

    To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland Ltd.

  15. Percutaneous biliary approach as a successful rescue procedure after failed endoscopic therapy for drainage in advanced hilar tumors.

    PubMed

    Jang, Sung Ill; Hwang, Jin-Hyeok; Lee, Kwang-Hun; Yu, Jeong-Sik; Kim, Hee Wook; Yoon, Chang Jin; Lee, Yoon Suk; Paik, Kyu Hyun; Lee, Sang Hyub; Lee, Dong Ki

    2017-04-01

    Palliative endoscopic or percutaneous biliary drainage is used for unresectable advanced hilar cancer (HC). The best option for drainage in Bismuth type III or IV HC has not been established. The aims of this study are to identify factors predictive of endoscopic stenting failure and evaluate the effectiveness of rescue percutaneous stenting in patients with advanced HC. Data from 110 patients with inoperable advanced HC were retrospectively reviewed. All received bilateral self-expandable metallic stents. Patients were divided into three groups: I, successful initial endoscopic stenting; II, unsuccessful initial endoscopic stenting, followed by percutaneous stenting; and III, initial percutaneous stenting. We analyzed clinical results and radiologic tumor characteristics. Baseline characteristics and clinical outcomes of all groups were similar, except the hospital stay was longer in group III than group I. Technical success rate was higher in groups II and III (100%) than in group I (72.4%). The functional success rate, stent patency time, patient survival time, and complication rate were similar between groups. Endoscopic stenting failed because of guide-wire passage failure (n = 12) or stent passage failure (n = 7). The only factor significantly associated with endoscopic failure was a smaller left intrahepatic duct-common bile duct angle. As clinical outcomes were generally similar between approaches, percutaneous stenting is recommended for patients with Bismuth type III or IV advanced HC. Acute left intrahepatic duct-common bile duct angulation predicts endoscopic stenting failure. If endoscopic stenting fails, immediate conversion to the percutaneous approach is a necessary and effective rescue method. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  16. Partially covered self-expandable metal stents versus polyethylene stents for malignant biliary obstruction: A cost-effectiveness analysis

    PubMed Central

    Barkun, Alan N; Adam, Viviane; Martel, Myriam; AlNaamani, Khalid; Moses, Peter L

    2015-01-01

    BACKGROUND/OBJECTIVE: Partially covered self-expandable metal stents (SEMS) and polyethylene stents (PES) are both commonly used in the palliation of malignant biliary obstruction. Although SEMS are significantly more expensive, they are more efficacious than PES. Accordingly, a cost-effectiveness analysis was performed. METHODS: A cost-effectiveness analysis compared the approach of initial placement of PES versus SEMS for the study population. Patients with malignant biliary obstruction underwent an endoscopic retrograde cholangiopancreatography to insert the initial stent. If the insertion failed, a percutaneous transhepatic cholangiogram was performed. If stent occlusion occurred, a PES was inserted at repeat endoscopic retrograde cholangiopancreatography, either in an outpatient setting or after admission to hospital if cholangitis was present. A third-party payer perspective was adopted. Effectiveness was expressed as the likelihood of no occlusion over the one-year adopted time horizon. Probabilities were based on a contemporary randomized clinical trial, and costs were issued from national references. Deterministic and probabilistic sensitivity analyses were performed. RESULTS: A PES-first strategy was both more expensive and less efficacious than an SEMS-first approach. The mean per-patient costs were US$6,701 for initial SEMS and US$20,671 for initial PES, which were associated with effectiveness probabilities of 65.6% and 13.9%, respectively. Sensitivity analyses confirmed the robustness of these results. CONCLUSION: At the time of initial endoscopic drainage for patients with malignant biliary obstruction undergoing palliative stenting, an initial SEMS insertion approach was both more effective and less costly than a PES-first strategy. PMID:26125107

  17. Removable esophageal stents have poor efficacy for the treatment of refractory benign esophageal strictures (RBES).

    PubMed

    Dan, D T; Gannavarapu, B; Lee, J G; Chang, K; Muthusamy, V R

    2014-08-01

    With the recent availability of removable esophageal stents, endoscopic stenting has been utilized to treat refractory benign esophageal strictures (RBES). The objective of this study was to review the feasibility and effectiveness of removable esophageal stents to treat RBES. Patients who received removable esophageal stents for the treatment of RBES at the institution between 2004-2010 using its stent implantation logs and endoscopic database were retrospectively identified. Patient demographics, stricture etiology and location, stent and procedure characteristics, and clinical outcomes were obtained. Twenty-five patients with a mean age of 70 (72% male) underwent initial stent placement; 24 were successful. Overall clinical success was achieved in five of the 19 patients (26%) ultimately undergoing stent removal. RBES etiologies included anastomotic (13), radiation (5), peptic (3), chemotherapy (1), scleroderma (1), and unknown (2). Alimaxx-E (Merit-Endotek, South Jordan, UT, USA) stents were placed in 20 patients and Polyflex (Boston Scientific, Natick, MA, USA) stents were used in five patients. Immediate complications included failed deployment (1) and chest pain (7). Five patients died prior to stent removal. Stent migration was found in 53% (10/19) of patients who underwent stent removal: nine required additional therapy and one had symptom resolution. Out of the nine patients without stent migration, five required additional therapy and four had symptom resolution. Although placement of removable esophageal stents for RBES is technically feasible, it is frequently complicated by stent migration and chest pain. In addition, few patients achieved long-term stricture resolution after initial stenting. In this study, most patients ultimately required repeated stenting and/or dilations to maintain relief of dysphagia. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  18. Demonstration of bacterial biofilms in culture-negative silicone stent and jones tube.

    PubMed

    Parsa, Kami; Schaudinn, Christoph; Gorur, Amita; Sedghizadeh, Parish P; Johnson, Thomas; Tse, David T; Costerton, John W

    2010-01-01

    To demonstrate the presence of bacterial biofilms on a dacryocystorhinostomy silicone stent and a Jones tube. One dacryocystorhinostomy silicone stent and one Jones tube were removed from 2 patients who presented with an infection of their respective nasolacrimal system. Cultures were obtained, and the implants were processed for scanning electron microscopy and confocal laser scanning microscopy, advanced microscopic methods that are applicable for detection of uncultivable biofilm organisms. Routine bacterial cultures revealed no growth, but bacterial biofilms on outer and inner surfaces of both implants were confirmed by advanced microscopic techniques. To the authors' knowledge, this is the first article that documents the presence of biofilms on a Crawford stent or a Jones tube on patients who presented with infections involving the nasolacrimal system. Although initial cultures revealed absence of any bacterial growth, confocal laser scanning microscopy and scanning electron microscopy documented bacterial colonization. Clinicians should consider the role of biofilms and the limitation of our standard culturing techniques while treating patients with device- or implant-related infections.

  19. Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature.

    PubMed

    King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J

    2015-12-01

    The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (p<0.001), ICH (p=0.001), mortality among all patients (p=0.03), and recanalization (p=0.02) were more commonly reported in NEU treated aneurysms. The ENT system was also associated with higher reported complete occlusion at follow-up (p<0.001). This literature review represents the largest and most robust comparison of stent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Time Sequence Evaluation of Biliary Stent Occlusion by Dissection Analysis of Retrieved Stents.

    PubMed

    Kwon, Chang-Il; Gromski, Mark A; Sherman, Stuart; Easler, Jeffrey J; El Hajj, Ihab I; Watkins, James; Fogel, Evan L; McHenry, Lee; Lehman, Glen A

    2016-08-01

    Multiple factors can affect the occlusion of plastic stents. Previous data demonstrate that side holes may induce more biofilm formation probably via microturbulence and bile flow disturbances that could lead to occlusion. These results, however, have not been replicated in subsequent clinical studies with different methods. The objective of this study is to evaluate the physical characteristics of plastic stent occlusion over time. This is a plastic stent sequential analysis study. Biliary stents removed via ERCP from February 24, 2015, to June 2, 2015, were included. One hundred and forty-eight retrieved straight-type plastic stents were longitudinally cut by a custom-made cutting device. These dissected stents were then evaluated in detail with regard to the location of stent occlusion and the stent patency period. Location of stent occlusive debris was the primary outcome in this study. Biofilm formations and occlusions by debris were sequentially but separately tallied. Biofilm formations were initially seen around the side hole areas within 30 days and spread to the entire stent by 60 days. Then, occlusion process by debris was mainly initiated by 80 days and progressed to full occlusion by median of 90 days. Although some occlusions were also observed around the side hole areas within 30 days, affected areas were more widely observed after biofilm formation. This study is the first to attempt to describe the distribution of stent occlusions over time. These observations may help guide future stent development.

  1. Radiologic Placement of Uncovered Stents for the Treatment of Malignant Colonic Obstruction Proximal to the Descending Colon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, Jehong; Kwon, Se Hwan, E-mail: Kwon98@khu.ac.kr; Lee, Chang-Kyun

    PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructivemore » symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.« less

  2. Upper Gastrointestinal Stent Insertion in Malignant and Benign Disorders

    PubMed Central

    Kang, Hyoun Woo

    2015-01-01

    Upper gastrointestinal (GI) stents are increasingly being used to manage upper GI obstructions. Initially developed for palliative treatment of esophageal cancer, upper GI stents now play an emerging role in benign strictures of the upper GI tract. Because recurrent obstruction and stent-related complications are common, new modifications of stents have been implemented. Self-expandable metal stents (SEMS) have replaced older plastic stents. In addition, newly designed SEMS have been developed to prevent complications. This review provides an overview of the various types, indications, methods, complications, and clinical outcomes of upper GI stents in a number of malignant and benign disorders dividing the esophagus and gastroduodenum. PMID:26064817

  3. Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics

    PubMed Central

    Bernardini, Annarita; Larrabide, Ignacio; Morales, Hernán G.; Pennati, Giancarlo; Petrini, Lorenza; Cito, Salvatore; Frangi, Alejandro F.

    2011-01-01

    Cerebral aneurysms are abnormal focal dilatations of artery walls. The interest in virtual tools to help clinicians to value the effectiveness of different procedures for cerebral aneurysm treatment is constantly growing. This study is focused on the analysis of the influence of different stent deployment approaches on intra-aneurysmal haemodynamics using computational fluid dynamics (CFD). A self-expanding stent was deployed in an idealized aneurysmatic cerebral vessel in two initial positions. Different cases characterized by a progression of simplifications on stent modelling (geometry and material) and vessel material properties were set up, using finite element and fast virtual stenting methods. Then, CFD analysis was performed for untreated and stented vessels. Haemodynamic parameters were analysed qualitatively and quantitatively, comparing the cases and the two initial positions. All the cases predicted a reduction of average wall shear stress and average velocity of almost 50 per cent after stent deployment for both initial positions. Results highlighted that, although some differences in calculated parameters existed across the cases based on the modelling simplifications, all the approaches described the most important effects on intra-aneurysmal haemodynamics. Hence, simpler and faster modelling approaches could be included in clinical workflow and, despite the adopted simplifications, support clinicians in the treatment planning. PMID:22670204

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanciego, Carlos; Miguel, Silvia De; Padilla, Manuel

    The purpose of this study was to evaluate, in a prospective, single-center study, the effectiveness of Song's polyurethane stents, modified 'in-house,' in the percutaneous management of epiphora. Patients (n = 170; age range 18-83, mean = 64; 50 male, 120 female) with severe epiphora had the modified stents inserted (183 eyes/195 stents) to treat unilateral/bilateral and complete/partial obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 119 cases (61%) and chronic dacryocystitis in 76 (39%). The set designed by Song was used in all patients but modified by us such that the extreme end is cone-shaped.more » The original technique was slightly modified by us and the procedure was conducted on an outpatient basis. The initial technical success rate of stent placement was 97%. Resolution of epiphora was complete in 180 eyes and partial in 3. On follow-up (mean = 18 months; range: 2 days to 24 months), 165 of 195 stents (85%) remained patent. Primary patency rates at follow-up were 86%, 84%, 84%, and 79% in the first 6 months, second and third 6 months, and the present (24 months), respectively. Stents became obstructed in 30 patients, but all but 2 were easily withdrawn and 20 of these patients remained asymptomatic for a mean of 14 months (secondary patency of 67%). Following stent removal, the withdrawn stent was replaced with a new stent in the same intervention on 14 occasions. In another six cases, patency was re-established without the need of a second stent. The procedure is simple and safe, both in stent insertion as well as in mechanical de-blocking and withdrawal when occluded. Success was >80 % in the short term (1-year follow-up). Stenting failure does not preclude other treatment because with the modification that we had introduced, the extreme end of the stent becomes more accessible to mechanical de-blocking, withdrawal, and relocation. The levels of primary and secondary patencies are promising and warrant more extensive investigation.« less

  5. [The Predictive Factors of Stent Failure in the Treatment of Malignant Extrinsc Ureteral Obstruction Using Internal Ureteral Stents].

    PubMed

    Matsuura, Hiroshi; Arase, Shigeki; Hori, Yasuhide; Tochigi, Hiromi

    2017-12-01

    In this study, we retrospectively reviewed the experiences at our single institute in the treatment of malignant extrinsic ureteral obstruction (MUO) using ureteral stents to investigate the clinical outcomes and the predictive factors of stent failure. In 52 ureters of 38 patients who had radiologically significant hydronephrosis due to MUO, internal ureteral stents (The BARD(R) INLAY(TM) ureteral stent set) were inserted. The median follow-up interval after the initial stent insertion was 124.5 days (4-1,120). Stent failure occurred in 8 ureters (15.4%) of the 7 patients. The median interval from the first stent insertion to stent failure was 88 days (1-468). A Cox regression multivariate analysis showed that the significant predictors of stent failure were bladder invasion. Based on the possibility of stent failure, the adaptation of the internal ureteral stent placement should be considered especially in a patient with MUO combined with bladder invasion.

  6. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    PubMed

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  7. A stent for co-delivering paclitaxel and nitric oxide from abluminal and luminal surfaces: Preparation, surface characterization, and in vitro drug release studies

    NASA Astrophysics Data System (ADS)

    Gallo, Annemarie; Mani, Gopinath

    2013-08-01

    Most drug-eluting stents currently available are coated with anti-proliferative drugs on both abluminal (toward blood vessel wall) and luminal (toward lumen) surfaces to prevent neointimal hyperplasia. While the abluminal delivery of anti-proliferative drugs is useful for controlling neointimal hyperplasia, the luminal delivery of such drugs impairs or prevents endothelialization which causes late stent thrombosis. This research is focused on developing a bidirectional dual drug-eluting stent to co-deliver an anti-proliferative agent (paclitaxel - PAT) and an endothelial cell promoting agent (nitric oxide - NO) from abluminal and luminal surfaces of the stent, respectively. Phosphonoacetic acid, a polymer-free drug delivery platform, was initially coated on the stents. Then, the PAT and NO donor drugs were co-coated on the abluminal and luminal stent surfaces, respectively. The co-coating of drugs was collectively confirmed by the surface characterization techniques such as Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), 3D optical surface profilometry, and contact angle goniometry. SEM showed that the integrity of the co-coating of drugs was maintained without delamination or cracks formation occurring during the stent expansion experiments. In vitro drug release studies showed that the PAT was released from the abluminal stent surfaces in a biphasic manner, which is an initial burst followed by a slow and sustained release. The NO was burst released from the luminal stent surfaces. Thus, this study demonstrated the co-delivery of PAT and NO from abluminal and luminal stent surfaces, respectively. The stent developed in this study has potential applications in inhibiting neointimal hyperplasia as well as encouraging luminal endothelialization to prevent late stent thrombosis.

  8. Role of stenting in gastrointestinal benign and malignant diseases

    PubMed Central

    Mangiavillano, Benedetto; Pagano, Nico; Arena, Monica; Miraglia, Stefania; Consolo, Pierluigi; Iabichino, Giuseppe; Virgilio, Clara; Luigiano, Carmelo

    2015-01-01

    Advances in stents design have led to a substantial increase in the use of stents for a variety of digestive diseases. Initially developed as a non-surgical treatment for palliation of esophageal cancer, the stents now have an emerging role in the management of malignant and benign conditions as well as in all segments of the gastrointestinal tract. In this review, relevant literature search and expert opinions have been used to evaluate the key-role of stenting in gastrointestinal benign and malignant diseases. PMID:25992186

  9. Prospective evaluation of a newly designed T-configured stent graft system for palliative treatment of advanced hilar malignant biliary obstructions.

    PubMed

    Gwon, Dong Il; Ko, Gi-Young; Yoon, Hyun-Ki; Kim, Jin Hyoung; Lee, Jae Myeong; Ohm, Joon-Young; Sung, Kyu-Bo

    2010-09-01

    To investigate the technical and clinical safety and efficacy of using a newly designed T-configured stent graft for palliative treatment of advanced hilar malignant biliary obstructions. This is a prospective study that enrolled 30 patients who had malignant hilar obstructions from May 2007 to November 2008. All patients were treated with percutaneous transhepatic placement of two specially designed stent grafts in a T configuration. Technical success, evaluation of blocked branching ducts, complications, clinical success, stent patency time, and patient survival rates were analyzed. Stent graft deployment was technically successful in all patients. The bilirubin level and the bile duct diameter decreases were statistically significant after stent placement (P < .001), and all patients showed clinical improvement. Minor complications, including procedure-related complications (self-limiting hemobilia [n = 3], perihepatic biloma [n = 1], and acute pancreatitis [n = 1]) and rapidly resolving cholangitis (n = 5), occurred in ten patients (33.3%). Major complications, including acute cholecystitis, occurred in three patients (10%). Stent occlusion occurred in 12 patients (40%) after a mean period of 160 days (range, 82-307 days). The median survival and stent patency times were 334 days (range, 195.6-472.4 days) and 279 days (range, 194.7-363.3 days), respectively. There were no statistical differences in age, sex, Bismuth type, or number of blocked branching ducts. The initial results of percutaneous palliative treatment of advanced hilar malignancies with T-configured stent grafts suggest that they are safe and potentially clinically effective. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.

  10. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study.

    PubMed

    Walter, Daisy; Laleman, Wim; Jansen, Jeroen M; van Milligen de Wit, A W M; Weusten, Bas L; van Boeckel, Petra G; Hirdes, Meike M; Vleggaar, Frank P; Siersema, Peter D

    2015-05-01

    Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. To evaluate the efficacy of a novel FCSEMS with antimigration features. Prospective cohort study. Five hospitals in the Netherlands and Belgium. Consecutive patients with BBS. FCSEMS placement for 3 months. Initial and long term clinical success, stent migration rate and safety. Thirty-eight patients (24 men; mean age, 53 ± 16 years) were included. Stent placement was technically successful in 37 patients (97%). Two patients died of an unrelated cause before stent removal, and no data on these patients were available on stricture resolution. Initial clinical success was achieved in 28 of 35 patients (80%). During follow-up after stent removal, a symptomatic recurrent stricture developed in 6 of 28 patients (21%). Overall, the long-term clinical success rate was 63% (22 of 35 patients). Stent migration occurred in 11 of 35 patients (31%), including 5 symptomatic (14%) and 6 asymptomatic (17%) migrations. In total, 11 serious adverse events occurred in 10 patients (29%), with cholangitis (n = 5) being most common. Nonrandomized study design. Good initial clinical success was achieved after placement of this novel FCSEMS, but stricture recurrence was in the upper range compared with other FCSEMSs. The antimigration design could not prevent migration in a significant number of patients with a persisting stricture. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Longitudinal Deformation of Distal Edge in a New-Generation Stent Caused by Guidewire Entrapment

    PubMed Central

    Taleb, Adam; Parikh, Gaurav

    2018-01-01

    Longitudinal stent deformation, described in some older stent geometries, prompted design modifications such as reinforcing struts on the proximal end. However, distal edges of stents—also subject to longitudinal force—have not been reinforced. We report a case of guidewire entrapment that deformed the distal edge of a new-generation stent during percutaneous coronary intervention, and we describe our efforts to restore the stent to its initial length. This case highlights the risk of manipulating equipment beyond the position of a newly deployed stent, the ongoing potential for deformation of distal edges in newer stent platforms, and the advisability of treating distal lesions before proximal ones. PMID:29556153

  12. Delayed relapse in pseudotumor cerebri due to new stenosis after transverse sinus stenting

    PubMed Central

    Winters, Hugh Stephen; Parker, Geoff; Halmagyi, Gabor Michael; Mehta, Ankur; Atkins, Thomas

    2015-01-01

    A patient presented with recurrent severe pseudotumor cerebri (PTC). Transverse sinus stenting is a very effective treatment option, however stenosis and intracranial hypertension can recur. In our patient, stenting initially resulted in resolution of papilloedema. However, after 5 years, a new stenosis developed which required further stenting. This case highlights the fact that, in patients with PTC who undergo transverse sinus stenting, a small proportion require repeat treatment due to formation of a new stenosis, usually adjacent to the existing stent. Patients with severe disease, such as ours, may be at higher risk of recurrence. Regardless of the severity, all patients who undergo stenting should have regular ocular follow-up. PMID:26351311

  13. Comparative Analysis of Sequential Proximal Optimizing Technique Versus Kissing Balloon Inflation Technique in Provisional Bifurcation Stenting: Fractal Coronary Bifurcation Bench Test.

    PubMed

    Finet, Gérard; Derimay, François; Motreff, Pascal; Guerin, Patrice; Pilet, Paul; Ohayon, Jacques; Darremont, Olivier; Rioufol, Gilles

    2015-08-24

    This study used a fractal bifurcation bench model to compare 6 optimization sequences for coronary bifurcation provisional stenting, including 1 novel sequence without kissing balloon inflation (KBI), comprising initial proximal optimizing technique (POT) + side-branch inflation (SBI) + final POT, called "re-POT." In provisional bifurcation stenting, KBI fails to improve the rate of major adverse cardiac events. Proximal geometric deformation increases the rate of in-stent restenosis and target lesion revascularization. A bifurcation bench model was used to compare KBI alone, KBI after POT, KBI with asymmetric inflation pressure after POT, and 2 sequences without KBI: initial POT plus SBI, and initial POT plus SBI with final POT (called "re-POT"). For each protocol, 5 stents were tested using 2 different drug-eluting stent designs: that is, a total of 60 tests. Compared with the classic KBI-only sequence and those associating POT with modified KBI, the re-POT sequence gave significantly (p < 0.05) better geometric results: it reduced SB ostium stent-strut obstruction from 23.2 ± 6.0% to 5.6 ± 8.3%, provided perfect proximal stent apposition with almost perfect circularity (ellipticity index reduced from 1.23 ± 0.02 to 1.04 ± 0.01), reduced proximal area overstretch from 24.2 ± 7.6% to 8.0 ± 0.4%, and reduced global strut malapposition from 40 ± 6.2% to 2.6 ± 1.4%. In comparison with 5 other techniques, the re-POT sequence significantly optimized the final result of provisional coronary bifurcation stenting, maintaining circular geometry while significantly reducing SB ostium strut obstruction and global strut malapposition. These experimental findings confirm that provisional stenting may be optimized more effectively without KBI using re-POT. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. A systematic review of biodegradable biliary stents: promising biocompatibility without stent removal.

    PubMed

    Siiki, Antti; Sand, Juhani; Laukkarinen, Johanna

    2018-05-18

    Biodegradable self-expanding stents are an emerging alternative to standard biliary stents as the development of endoscopic insertion devices advances. The aim was to systematically review the existing literature on biodegradable biliary stents. In-vivo studies on the use of biodegradable stents in the biliary duct were systematically reviewed from 1990 to 2017. Despite extensive research on the biocompatibility of stents, the experience so far on their clinical use is limited. A few favorable reports have recently been presented on endoscopically and percutaneously inserted self-expanding biodegradable polydioxanone stents in benign biliary strictures. Another potential indication appears to be postcholecystectomy leak of the cystic duct. The main benefit of biodegradable stents is that stent removal can be avoided. The biocompatibility of the current biodegradable stent materials, most prominently polydioxanone, is well documented. In the few studies currently available, biodegradable stents are reported to be feasible and safe, also in humans. The initial results of the endoscopic use of these stents in benign biliary stricture management and for treating postcholecystectomy bile leaks are promising. Further controlled studies on long-term clinical results and cost-effectiveness are needed.

  15. The forgotten ureteric JJ stent and its prevention: a prospective audit of the value of a ureteric stent logbook.

    PubMed

    Thomas, A Z; Casey, R G; Grainger, R; McDermott, T; Flynn, R; Thornhill, J A

    2007-01-01

    Temporary ureteric stent insertion is an integral part of modern endo-urological practice. Delayed stent removal or forgotten stents are associated with increased patient morbidity and complications which are often difficult to manage. We prospectively audited our ureteric stent insertion and removal logbook system to determine the value and effectiveness of our stent follow-up. Over a 1-year period, 210 ureteric stents were inserted in our urological unit. Of these, 47 (22.4%) patients were unaccounted as having their stents removed within the stent logbooks. One patient was lost to follow-up and re-presented with stent encrustation 10 months later. Our results in this audit suggest that our system of ureteric stent follow-up is not effective. We have now introduced a new system that we feel is a safer and a satisfactory alternative to the stent logbooks. This includes a patient education leaflet and removal date scheduling prior to discharge from hospital.

  16. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    PubMed

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Is pre-shock wave lithotripsy stenting necessary for ureteral stones with moderate or severe hydronephrosis?

    PubMed

    El-Assmy, Ahmed; El-Nahas, Ahmed R; Sheir, Khaled Z

    2006-11-01

    We performed a prospective, randomized clinical trial to evaluate the outcome of ureteral stents for solitary ureteral stones 2 cm or less in moderately or severely obstructed systems using shock wave lithotripsy. Between 2001 and 2004, 186 patients who met study criteria were randomized into 2 groups. Group 1 received a pre-shock wave lithotripsy 6Fr Double-J stent and group 2 had no stent. Patients were treated with a Dornier MFL 5000 lithotripter. Results were compared in terms of clearance rates, number of shock waves and sessions, irritative voiding symptoms, incidence of complications and secondary interventions. Failure was defined as the need for additional procedure(s) for stone extraction. Overall 164 patients (88.2%) became stone-free after shock wave lithotripsy. Complete stone fragmentation was achieved after 1 to 3 and more than 3 session in 108 (58.1%), 30 (16.1%), 13 (7%) and 14 patients (7.5%), respectively. Ureteral stent insertion did not affect the stone-free rate, which was 84.9% and 91.4% in groups 1 and 2, respectively (p = 0.25). There was no statistical difference in the re-treatment rate, flank pain or temperature in the 2 groups. However, all patients in the stented group significantly complained of side effects attributable to the stent, including dysuria, suprapubic pain, hematuria, pyuria and positive urinary culture. Pretreatment stenting provides no advantage over in situ shock wave lithotripsy for significantly obstructing ureteral calculi. Shock wave lithotripsy is reasonable initial therapy for ureteral stones 2 cm or less that cause moderate or severe hydronephrosis.

  18. Y-configuration double-stent-assisted coiling using two closed-cell stents for wide-neck basilar tip aneurysms.

    PubMed

    Jeon, Pyoung; Kim, Byung Moon; Kim, Dong Joon; Kim, Dong I K; Park, Keun Young

    2014-09-01

    This study aimed to evaluate clinical and angiographic outcomes of Y-configuration double-stent-assisted (Y-stent) coiling using two closed-cell stents for wide-necked basilar tip aneurysm (BTA). A total of 25 patients underwent Y-stent coiling using two closed-cell stents as a first-time treatment in 18 (3 ruptured) BTAs, retreatment in 2 BTAs and as a third treatment in 5 wide-necked BTAs. Clinical and angiographic outcomes were evaluated retrospectively. Treatment-related complications were three (12.0 %) thromboembolic infarctions due to two acute in-stent thromboses and one embolism. Twenty-two (88 %) patients had favorable outcomes (modified Rankin scale score [mRS], 0-2) during the follow-up period (mean, 30 months; range, 6-54 months). Two patients died: one from initial subarachnoid hemorrhage and the other from intracerebral hemorrhage due to underlying Moyamoya disease. Post-treatment angiograms showed complete occlusion in nine aneurysms, residual neck in 11 aneurysms and residual sac in five aneurysms. Follow-up angiograms were available at least once between 5 to 34 months (mean, 16 months) in 21 patients. Nineteen patients showed improved or stable states (complete occlusion, n = 17; residual neck, n = 2). Major recurrences occurred in two BTAs (9.5 %). Those two major recurrent aneurysms had been large-sized aneurysms at the initial coiling procedure. Both showed not only coil compaction but also progressive growth to giant-sized aneurysms and intra-aneurysmal thrombus formation at the Y-stent coiling as a third-time treatment. Y-stent coiling using two closed-cell stents is a safe and durable treatment option for wide-necked BTA, but may have limited efficacy for large/giant sized and thrombosed aneurysms.

  19. Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007).

    PubMed

    Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M

    2008-11-01

    To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

  20. Chronic Intraocular Inflammation as a Risk Factor for XEN Gel Stent Occlusion: A Case of Microscopic Examination of a Fibrin-obstructed XEN Stent.

    PubMed

    Gillmann, Kevin; Mansouri, Kaweh; Bravetti, Giorgio Enrico; Mermoud, André

    2018-06-05

    In recent years microinvasive glaucoma surgery (MIGS) has risen in popularity. Amongst MIGS options is the XEN gel stent (Allergan Plc, Dublin, Ireland), a 45▒μm wide ab-interno microstent. It has proven effective in lowering IOP with low complication rates. However, XEN gel stents can become obstructed and cause postoperative rise in IOP. The causes and predicting factors for such obstructions still requires further research. We describe the case of a 69-year old male patient, with traumatic glaucoma and chronic intraocular inflammation demonstrated by laser flare photometry, following childhood trauma and anterior segment surgery. Uncontrollable IOP despite maximal antiglaucomatous therapy was managed with XEN-augmented Baerveldt surgery. Despite good initial filtration and IOP control, the XEN stent became obstructed and was surgically replaced. After a month, the new stent became obstructed and was replaced by a thicker-lumened Baerveldt tube. This restored good filtration, and adequate IOP was maintained post-operatively. Microscopic examination of the obstructed XEN stent showed a dense fibrin plug. This case report shows that fibrin formation could be an important factor in XEN gel stent obstruction, even in initially successfully filtering stents. The association of fibrinogenesis and intraocular inflammation could add a note of caution to the use of XEN gel stents in complicated cataract surgery, or advocate for aggressive anti-inflammatory treatments post-operatively. This could lead to a refinement in success predictors and better patient selection for XEN surgery. Finally, this could open the way to new management options for persistent obstructions, including pharmaceutical fibrinolysis.

  1. ST-Segment Elevation Myocardial Infarction with Acute Stent Thrombosis Presenting as Intractable Hiccups: An Unusual Case.

    PubMed

    Zhang, Fan; Tongo, Nosakhare Douglas; Hastings, Victoria; Kanzali, Parisa; Zhu, Ziqiang; Chadow, Hal; Rafii, Shahrokh E

    2017-04-29

    BACKGROUND Acute coronary syndrome (ACS) can present with atypical chest pain or symptoms not attributed to heart disease, such as indigestion. Hiccups, a benign and self-limited condition, can become persistent or intractable with overlooked underlying etiology. There are various causes of protracted hiccups, including metabolic abnormalities, psychogenic disorders, malignancy, central nervous system pathology, medications, pulmonary disorders, or gastrointestinal etiologies. It is rarely attributed to cardiac disease. CASE REPORT We report a case of intractable hiccups in a 51-year-old male with cocaine related myocardial infarction (MI) before and after stent placement. Coronary angiogram showed in-stent thrombosis of the initial intervention. Following thrombectomy, balloon angioplasty, and stent, the patient recovered well without additional episodes of hiccups. Although hiccups are not known to present with a predilection for a particular cause of myocardial ischemia, this case may additionally be explained by the sympathomimetic effects of cocaine, which lead to vasoconstriction of coronary arteries. CONCLUSIONS Hiccups associated with cardiac enzyme elevation and EKG ST-segment elevation before and after percutaneous coronary intervention (PCI) maybe a manifestation of acute MI with or without stent. The fact that this patient was a cocaine user may have contributed to the unique presentation.

  2. A Feasibility Study of a New Unibody Branched Stent Graft Applied to Reconstruct the Canine Aortic Arch.

    PubMed

    Li, W; Zhai, S; Xu, K; Li, Q; Zhong, H; Li, T; Zhang, Z

    2018-06-01

    The aim was to evaluate the feasibility and safety of a new unibody branched stent graft for the reconstruction of the canine aortic arch. The unibody branched stent grafts included single branched stent grafts and double branched stent grafts. The main stent graft and branched limbs were sutured together. The branched stent grafts were folded into the introducer system, which consisted of a double channel catheter, a detachable sleeve, and an introducer sheath. The branched stent grafts were introduced and deployed into the aortic arch by the delivery system. Twenty adult mongrel dogs were used for the experiments. Ten dogs were implanted with single branched stent grafts; the other 10 were implanted with double branched stent grafts. The surviving animals were followed up for 3 months. Computed tomography angiography (CTA) was performed to observe the status of the branched stent grafts. All the unibody branched stent grafts were successfully implanted into the canine aortic arches. The technical success rate was 100%. There was no cerebral infarction, paraplegia or incision infection. CTA showed that all the branched stent grafts were patent; there was no endoleak or stent migration. The unibody branched stent graft system could be used to reconstruct the aortic arch. The animal experimental procedures demonstrated the safety and feasibility of the unibody branched stent graft system. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  3. TAVR Through Heavily Calcified Aorta Following Atheroma Retrieval With the "Elevator" Technique.

    PubMed

    Senguttuvan, N Boopathy; Ellozy, Sharif; Tejani, Furqan; Kovacic, Jason; Kini, Annapoorna S; Sharma, Samin K; Dangas, George D

    2015-10-01

    An 86-year-old Caucasian female with severe symptomatic, inoperable aortic stenosis was accepted for high-risk transfemoral transcatheter aortic valve replacement (TAVR) approach due to severe calcification of the aorta. During initial passage of a 22 Fr sheath, there was dislodgment with proximal migration of a circumferential tunnel of calcium from the infrarenal aorta. A novel "elevator" technique was used to secure and retrieve the dislodged aorta en bloc back to its original infrarenal aortic position and allow in situ fixation with stenting. A new TAVR system was then successfully placed through the stent and a 23 mm Edwards Sapien valve (Edwards Lifesciences) was implanted as planned. In case of calcification protruding into the lumen of the aorta and limiting the passage of the large valve delivery system sheath, the obstruction can be managed by stenting the calcification against the luminal wall under fluoroscopic and intravascular-ultrasound guidance, allowing successful passage of the valve delivery system. The elevator technique allows axial transportation of any calcified vascular fragments, should they become dislodged.

  4. [The bioresorbable coronary stent: a revolution].

    PubMed

    Koegler, Flora; De Benedetti, Edoardo

    2013-04-10

    Coronary angioplasty has undergone several technological revolutions: starting with balloon angioplasty, then with bare metal stent and finally with drug eluting stent (DES), this technique is now mature. However, once we thought the problem of instent restenosis solved with DES, new concerns arise with late and very late stent thrombosis. Should we therefore proscribe DES? How long should be the duration of dual antiplatelet therapy? And how should we manage the patients who need a surgery and are at high risk of bleeding? Are bioresorbable stents the final solution with their initial mechanical properties, then with their drug eluting effect against intra-stent restenosis, and finally with their complete resorption which leaves the artery free of any foreign material?

  5. Immediate stent recoil in an anastomotic vein graft lesion treated by cutting balloon angioplasty.

    PubMed

    Akkus, Nuri Ilker; Budeepalli, Jagan; Cilingiroglu, Mehmet

    2013-11-01

    Saphenous vein graft (SVG) anastomotic lesions can have significant fibromuscular hyperplasia and may be resistant to balloon angioplasty alone. Stents have been used successfully to treat these lesions. There are no reports of immediate stent recoil following such treatment in the literature. We describe immediate and persistent stent recoil in an anastomotic SVG lesion even after initial and post-deployment complete balloon dilatation of the stent and its successful treatment by cutting balloon angioplasty. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  6. Behaviour of two typical stents towards a new stent evolution.

    PubMed

    Simão, M; Ferreira, J M; Mora-Rodriguez, J; Fragata, J; Ramos, H M

    2017-06-01

    This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interaction are used to assess the haemodynamic impact of two types of coronary stents implantation: (1) type 1-based on a strut-link stent geometry and (2) type 2-a continuous helical stent. Using data from a recent clinical stenosis, flow disturbances and consequent shear stress alterations introduced by the stent treatment are investigated. A relationship between stenosis and the induced flow fields for the two types of stent designs is analysed as well as the correlation between haemodynamics and vessel wall biomechanical factors during the initiation and development of stenosis formation in the coronary artery. Both stents exhibit a good performance in reducing the obstruction artery. However, stent type 1 presents higher radial deformation than the type 2. This deformation can be seen as a limitation with a long-term clinical impact.

  7. Dilatation by Soehendra stent retriever is feasible and effective in multiple deployment of metallic stents to malignant hilar biliary strictures.

    PubMed

    Kato, Hironari; Kawamoto, Hirofumi; Noma, Yasuhiro; Sonoyama, Takayuki; Tsutsumi, Koichiro; Fujii, Masakuni; Okada, Hiroyuki; Yamamoto, Kazuhide

    2013-01-01

    The endoscopic management of malignant hilar biliary strictures using multiple metallic stents (MS) is technically demanding, in the initial deployment of MS and the recovery from MS occlusion with deployment of multiple plastic stents (PS). We evaluated the outcomes of the application of a Soehendra stent retriever (SSR) as a dilator of intractable strictures. Fifty-nine patients with malignant hilar biliary strictures had multiple MS inserted using a partial stent-in-stent procedure. When we encountered intractable strictures, we adopted SSR to dilate the stricture and the interstice of the MS. We evaluated the success rate of MS or PS deployment after SSR application and procedural complications. Five of 59 patients (8%) were subjected to SSR application for the initial MS deployment. MS were successfully deployed in all of these patients (100%). MS occlusion was noted in 27 patients. We applied SSR to seven patients (26%) for the deployment of multiple PS after MS occlusion. In five patients (71%), successful PS deployment was achieved after the SSR application. No complications related to dilatation using SSR occurred in any patient. SSR proved to be a potent dilator of difficult strictures in the management of malignant hilar biliary strictures.

  8. ST-Segment Elevation Myocardial Infarction with Acute Stent Thrombosis Presenting as Intractable Hiccups: An Unusual Case

    PubMed Central

    Zhang, Fan; Tongo, Nosakhare Douglas; Hastings, Victoria; Kanzali, Parisa; Zhu, Ziqiang; Chadow, Hal; Rafii, Shahrokh E.

    2017-01-01

    Patient: Male, 51 Final Diagnosis: ST-segment elevation myocardial infarction with acute stent thrombosis Symptoms: Chest pain • hiccups Medication: — Clinical Procedure: — Specialty: Cardiology Objective: Unusual clinical course Background: Acute coronary syndrome (ACS) can present with atypical chest pain or symptoms not attributed to heart disease, such as indigestion. Hiccups, a benign and self-limited condition, can become persistent or intractable with overlooked underlying etiology. There are various causes of protracted hiccups, including metabolic abnormalities, psychogenic disorders, malignancy, central nervous system pathology, medications, pulmonary disorders, or gastrointestinal etiologies. It is rarely attributed to cardiac disease. Case Report: We report a case of intractable hiccups in a 51-year-old male with cocaine related myocardial infarction (MI) before and after stent placement. Coronary angiogram showed in-stent thrombosis of the initial intervention. Following thrombectomy, balloon angioplasty, and stent, the patient recovered well without additional episodes of hiccups. Although hiccups are not known to present with a predilection for a particular cause of myocardial ischemia, this case may additionally be explained by the sympathomimetic effects of cocaine, which lead to vasoconstriction of coronary arteries. Conclusions: Hiccups associated with cardiac enzyme elevation and EKG ST-segment elevation before and after percutaneous coronary intervention (PCI) maybe a manifestation of acute MI with or without stent. The fact that this patient was a cocaine user may have contributed to the unique presentation. PMID:28455489

  9. The modified pancreatic stent system for prevention of post-ERCP pancreatitis: a case-control study.

    PubMed

    Zhang, Cheng; Yang, Yu-Long; Ma, Yue-Feng; Zhang, Hong-Wei; Li, Jing-Yi; Lin, Mei-Ju; Shi, Li-Jun; Qi, Chun-Chun

    2017-10-18

    Prophylactic pancreatic stents after endoscopic retrograde cholangiopancreatography (ERCP) can help prevent post-ERCP pancreatitis. However most of the pancreatic stents need to be removed by another ERCP. The aim of this observational study was to investigate the feasibility and effectiveness of the modified pancreatic stent system for prevention of post-ERCP pancreatitis. From November 2013 to November 2015, a total of 230 patients who had prophylactic pancreatic stent placed for prevention of post-ERCP pancreatitis at a single institution were identified and stratified. In this case-control design, 150 patients received an ordinary pancreatic stent, and 80 patients received the modified pancreatic stent. The main outcome measures were the difficulty level and complications of pancreatic stent placement and extraction between the two groups. In ordinary group, the average time of pancreatic stent and nasal biliary drainage placement was 3.5 ± 0.6 min. There were 13 cases of stent proximal migration (8.7%), 20 cases of stent spontaneous abscission (13.3%), 5 cases of acute pancreatitis (3.3%) (2 cases for stent abscission) and 7 cases of hyperamylasemia (4.7%) after ERCP. One hundred thirty patients received extra duodenoscope (86.7%) to remove the stent, and 4 cases had acute pancreatitis and 5 patients had hyperamylasemia after removing the proximal migratory stents. In modified group, the average time of pancreatic stent system placement was 4.9 ± 0.7 min, but there was only one case of stent abscission (1.3%), 2 cases of acute pancreatitis (2.5%) and 3 cases of hyperamylasemia (3.8%). The new pancreatic stents were removed directly under x-ray without complication. The modified pancreatic stent system has the same effect of preventing post-ERCP pancreatitis, lower rate of stents proximal migration and spontaneous abscission, and the advantage of easier removed compared with ordinary pancreatic stent.

  10. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model--a report on the Virtual Intracranial Stenting Challenge 2007.

    PubMed

    Radaelli, A G; Augsburger, L; Cebral, J R; Ohta, M; Rüfenacht, D A; Balossino, R; Benndorf, G; Hose, D R; Marzo, A; Metcalfe, R; Mortier, P; Mut, F; Reymond, P; Socci, L; Verhegghe, B; Frangi, A F

    2008-07-19

    This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and interventional planning.

  11. Computer Simulation of the Mechanical Behaviour of Implanted Biodegradable Stents in a Remodelling Artery

    NASA Astrophysics Data System (ADS)

    Boland, Enda L.; Grogan, James A.; Conway, Claire; McHugh, Peter E.

    2016-04-01

    Coronary stents have revolutionised the treatment of coronary artery disease. While coronary artery stenting is now relatively mature, significant scientific and technological challenges still remain. One of the most fertile technological growth areas is biodegradable stents; here, there is the possibility to generate stents that will break down in the body once the initial necessary scaffolding period is past (6-12 months) (Grogan et al. in Acta Biomater 7:3523, 2011) and when the artery has remodelled (including the formation of neo-intima). A stent angioplasty computational test-bed has been developed by the authors, based on the Abaqus software (DS-SIMULIA, USA), capable of simulating stent tracking, balloon expansion, recoil and in vivo loading in a atherosclerotic artery model. Additionally, a surface corrosion model to simulate uniform and pitting corrosion of biodegradable stents and a representation of the active response of the arterial tissue following stent implantation, i.e. neointimal remodelling, has been developed. The arterial neointimal remodelling simulations with biodegradable stent corrosion demonstrate that the development of new arterial tissue around the stent struts has a substantial effect on the mechanical behaviour of degrading stents.

  12. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    PubMed

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  13. Successful management of multiple esophagorespiratory fistulas using two types of stent: report of a case.

    PubMed

    Hamai, Yoichi; Hihara, Jun; Emi, Manabu; Okita, Riki; Shimizu, Katsuhiko; Okada, Morihito

    2011-04-01

    We herein describe a 41-year-old man with esophageal cancer who developed three esophagorespiratory fistulas (ERFs) that were successfully treated using one esophageal and three airway stents. A self-expandable metallic stent (SEMS) was initially inserted into the esophagus to close an ERF in the right bronchus. However, two new ERFs developed in the trachea and the left main bronchus 3 months later because of pressure necrosis and penetration of the esophageal SEMS. These secondary ERFs were subsequently closed using two silicone stents, together with one SEMS in the airway. This experience suggests that appropriate stenting can control multiple and large ERFs.

  14. Endoscopic management of malignant biliary obstruction by means of covered metallic stents: primary stent placement vs. re-intervention.

    PubMed

    Kida, M; Miyazawa, S; Iwai, T; Ikeda, H; Takezawa, M; Kikuchi, H; Watanabe, M; Imaizumi, H; Koizumi, W

    2011-12-01

    Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Occlusion of covered metallic stents now occurs in about half of all patients with malignant biliary strictures. The removal of metallic stents followed by placement of a second stent has been attempted, but outcomes remain controversial. The aim of the current study was to evaluate the effectiveness and safety of the primary placement and secondary placement (re-intervention) of covered metallic stents and to assess the feasibility and safety of stent removal. The study included 186 patients with unresectable malignant biliary strictures who underwent primary stent placement between October 2001 and March 2010.  Covered biliary self-expandable metal stents (SEMSs) were removed in 39 of these patients, and 36 underwent re-intervention. The patency times, occlusion rates of the first stent and re-intervention, success rates of stent removal, and complications were investigated. Covered SEMSs were placed in 186 patients. The median patency time of the first stent was 352 days. Stent occlusion occurred in 48.9 % of the patients and was mainly caused by debris or food residue (37 %), dislocation (19 %), and migration with hyperplasia (19 %). Stent removal was attempted in 50 patients and was successful without complication in 39 (78 %). Most of the patients in whom stent removal was unsuccessful had migration with hyperplasia. The median patency time of the second stent was 263 days. The stent patency time did not significantly differ between the first and the second stent. Covered SEMSs could be safely removed at the time of stent occlusion. Patency rates were similar for initial stent placement and re-intervention. © Georg Thieme Verlag KG Stuttgart · New York.

  15. The Integrity bare-metal stent made by continuous sinusoid technology.

    PubMed

    Turco, Mark A

    2011-05-01

    The Integrity Coronary Stent System (Medtronic Vascular, CA, USA) is a low-profile, open-cell, cobalt-chromium-alloy advanced bare-metal iteration of the well-known Driver/Micro-Driver Coronary Stent System (Medtronic Vascular). The Integrity stent is made with a process called continuous sinusoid technology. This process allows stent construction via wrapping a single thin strand of wire around a mandrel in a sinusoid configuration, with laser fusion of adjacent crowns. The wire-forming process and fusion pattern provide the stent with a continuous preferential bending plane, intended to allow easier access to, and smoother tracking within, distal and tortuous vessels while radial strength is maintained. Continuous sinusoid technology represents innovation in the design of stent platforms and will provide a future stent platform for newer technology, including drug-eluting stent platforms, drug-filled stents and core wire stents.

  16. Influence of strut cross-section of stents on local hemodynamics in stented arteries

    NASA Astrophysics Data System (ADS)

    Jiang, Yongfei; Zhang, Jun; Zhao, Wanhua

    2016-05-01

    Stenting is a very effective treatment for stenotic vascular diseases, but vascular geometries altered by stent implantation may lead to flow disturbances which play an important role in the initiation and progression of restenosis, especially in the near wall in stented arterial regions. So stent designs have become one of the indispensable factors needed to be considered for reducing the flow disturbances. In this paper, the structural designs of strut cross-section are considered as an aspect of stent designs to be studied in details. Six virtual stents with different strut cross-section are designed for deployments in the same ideal arterial model. Computational fluid dynamics (CFD) methods are performed to study how the shape and the aspect ratio (AR) of strut cross-section modified the local hemodynamics in the stented segments. The results indicate that stents with different strut cross-sections have different influence on the hemodynamics. Stents with streamlined cross-sectional struts for circular arc or elliptical arc can significantly enhance wall shear stress (WSS) in the stented segments, and reduce the flow disturbances around stent struts. The performances of stents with streamlined cross-sectional struts are better than that of stents with non-streamlined cross-sectional struts for rectangle. The results also show that stents with a larger AR cross-section are more conductive to improve the blood flow. The present study provides an understanding of the flow physics in the vicinity of stent struts and indicates that the shape and AR of strut cross-section ought to be considered as important factors to minimize flow disturbance in stent designs.

  17. Sensor to detect endothelialization on an active coronary stent

    PubMed Central

    2010-01-01

    Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks. PMID:21050471

  18. Allium Stents: A Novel Solution for the Management of Upper and Lower Urinary Tract Strictures

    PubMed Central

    Bahouth, Zaher; Moskovitz, Boaz; Halachmi, Sarel; Nativ, Ofer

    2017-01-01

    Stents are widely use in endoscopic urological procedures. One of the most important indications is the treatment of urinary tract strictures. Allium™ Medical has introduced several types of stents for the treatment of different types of urinary tract strictures, based on anatomic location. All the stents are made of nitinol and coated with a co-polymer that reduces encrustations. These stents are self-expandable and have a large caliber and a high radial force. They have different shapes, designed especially for the treatment of each type of stricture. One of the most important features of Allium-manufactured stents is the ease of removal, due to their special unraveling feature. The company has introduced the Bulbar Urethral Stent (BUS) for treatment of bulbar urethral strictures; a rounded stent available in different lengths. Initial data on 64 patients with bulbar urethral stricture treated with the BUS showed a significant improvement in symptoms, with minimal complications and few adverse events. For treatment of prostate obstruction in patients unfit for surgery or unwilling to undergo a classical prostatic surgery, the Triangular Prostatic Stent (TPS) was introduced, which has a triangular shape that fits in the prostatic urethra. Its body has a high radial force attached to an anchor (which prevents migration) through a trans-sphincteric wire (which reduces incontinence rate). Initial data on 51 patients showed significant improvement in symptoms and in urinary peak flow rate, with a relatively small number of complications. The Round Posterior Stent (RPS) was designed for treatment of post radical prostatectomy bladder neck contracture. This short, round stent has an anchor, which is placed in the bladder neck. This stent being relatively new, the clinical data are still limited. Ureteral strictures can be treated with the Ureteral Stent (URS), which is round-shaped, available in different lengths, and has an anchor option (for very distal or very proximal strictures). We have previously published data on 107 URSs inserted in patients with ureteral stricture due to several etiologies, including patients who failed previous treatment. All patients were asymptomatic for a long period of follow-up after stent removal, with only one case of re-stenosis. In this paper, we review the urological “covered” stents produced by Allium Medical with the relevant clinical data available at the present time. PMID:28872453

  19. Allium Stents: A Novel Solution for the Management of Upper and Lower Urinary Tract Strictures.

    PubMed

    Bahouth, Zaher; Moskovitz, Boaz; Halachmi, Sarel; Nativ, Ofer

    2017-10-16

    Stents are widely use in endoscopic urological procedures. One of the most important indications is the treatment of urinary tract strictures. Allium™ Medical has introduced several types of stents for the treatment of different types of urinary tract strictures, based on anatomic location. All the stents are made of nitinol and coated with a co-polymer that reduces encrustations. These stents are self-expandable and have a large caliber and a high radial force. They have different shapes, designed especially for the treatment of each type of stricture. One of the most important features of Allium-manufactured stents is the ease of removal, due to their special unraveling feature. The company has introduced the Bulbar Urethral Stent (BUS) for treatment of bulbar urethral strictures; a rounded stent available in different lengths. Initial data on 64 patients with bulbar urethral stricture treated with the BUS showed a significant improvement in symptoms, with minimal complications and few adverse events. For treatment of prostate obstruction in patients unfit for surgery or unwilling to undergo a classical prostatic surgery, the Triangular Prostatic Stent (TPS) was introduced, which has a triangular shape that fits in the prostatic urethra. Its body has a high radial force attached to an anchor (which prevents migration) through a trans-sphincteric wire (which reduces incontinence rate). Initial data on 51 patients showed significant improvement in symptoms and in urinary peak flow rate, with a relatively small number of complications. The Round Posterior Stent (RPS) was designed for treatment of post radical prostatectomy bladder neck contracture. This short, round stent has an anchor, which is placed in the bladder neck. This stent being relatively new, the clinical data are still limited. Ureteral strictures can be treated with the Ureteral Stent (URS), which is round-shaped, available in different lengths, and has an anchor option (for very distal or very proximal strictures). We have previously published data on 107 URSs inserted in patients with ureteral stricture due to several etiologies, including patients who failed previous treatment. All patients were asymptomatic for a long period of follow-up after stent removal, with only one case of re-stenosis. In this paper, we review the urological "covered" stents produced by Allium Medical with the relevant clinical data available at the present time.

  20. Management of benign dynamic "A-shape" tracheal stenosis: a retrospective study of 60 patients.

    PubMed

    Plojoux, Jérôme; Laroumagne, Sophie; Vandemoortele, Thomas; Astoul, Philippe J; Thomas, Pascal A; Dutau, Hervé

    2015-02-01

    Benign tracheal stenosis complicates tracheal intubation or tracheostomy in 0.6% to 65% of cases. Surgical resection is the standard treatment. Endoscopic management is used for inoperable patients with 17% to 69% success. Dynamic "A-shape" tracheal stenosis (DATS) results in a dynamic stenosis with anterior fracture of tracheal cartilage and frequently associated posterior malacia. We report the results of our multidisciplinary management. Sixty patients with DATS were included. Management decision was made during initial bronchoscopy. When suitable, patients were referred to thoracic surgery for tracheal resection. Posterior localized tracheomalacia was treated with laser photocoagulation of the posterior tracheal wall. Tracheal stents were placed if the stenosis persisted after laser treatment. The choice of stent (straight silicone, hour-glass shaped silicone, T-tube, or fully-covered self-expandable metallic stent) was based on operator's judgment. After 12 to 18 months, stents were removed. If the stenosis persisted after stent removal, surgery was reconsidered. If surgery was not possible, a stent was replaced. In case of satisfactory result, a stent was replaced only after recurrence. Stable patients after treatment were considered as success, requirement of long-term tracheostomy or T tube as failure, and long-term stent as partial success. All patients developed DATS after tracheostomy. Thirty-three patients had posterior tracheomalacia. In 13 patients, mild stenosis required only endoscopic surveillance. Two patients were referred to thoracic surgery for tracheal resection surgery. Endoscopic management was the initial therapy in 45 patients (75%) and was considered successful in 23 patients (51%), partially successful in 10 (22%), and failed in 12 (27%). Five patients with successful outcomes required only laser therapy. Overall 70 stents were placed in 35 patients, with a migration rate of 31%. The DATS management was successful in 63%. Stent migration was frequent. Posterior tracheomalacia was successfully treated in selected cases, avoiding stent placement. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Flow-diverting Stent in the Treatment of Cervical Carotid Dissection and Pseudoaneurysm: Review of Literature and Case Report.

    PubMed

    Baptista-Sincos, Anna Paula Weinhardt; Simplício, Aline Bigatão; Sincos, Igor Rafael; Leaderman, Alex; Neto, Fernando Saliture; Moraes, Adjaldes; Aun, Ricardo

    2018-01-01

    The endovascular technique has been recommended over the past few years to extracranial carotid dissection and pseudoaneurysm with promising results, especially after medical therapy failure. Flow-diverting stents are an alternative for complex cases. These stents have proven to be effective treatment devices for intracranial aneurysms. The reference list of Pham's systematic review, published in 2011, and Seward's literature review, published in 2015, was considered, as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE and Literatura Latino-Americana e do Caribe em Ciências da Saúde. For carotid dissection and pseudoaneurysm, our review yielded 3 published articles including 12 patients. The technical success rate of flow-diverting stent was 100% with no procedural complication described. Mean clinical follow-up was 27.2 months (range 5-48), and in 5 months' angiographic follow-up, all lesions had healed. No new neurological events were reported during the clinical follow-up. Flow diverter stent use on intracranial and peripheral vascular surgery demonstrates satisfactory initial results, but it is still under investigation. There are very few cases treated till now and the initial results with flow-diverting stents to cervical carotid dissection are promising. In well-selected cases, where simple embolization or conventional stent is not appropriate, this technic may be considered. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. [A new generation of urethral stents--Allium in the therapy of symptomatic prostatic enlargement of various etiology].

    PubMed

    Marković, B B; Marković, Z; Yachia, D; Hadzi, Djokić J

    2007-01-01

    A number of urethral stents made of different materials, with different time of indwelling and different designs, primarily based on the vascular stent concept, have been applied in the clinical practice so far. According to the published studies, urethral stents have justified their clinical application, however with certain limitations. Within an attempt to overcome the limitations, a covered, temporary urethral stent was initially designed by Daniel Yachie and Ijko Markovi in Allium corporation from Israel. With its triangular shape, the stent is a replica of the obstructive prostatic urethral lumen. In has been applied in a series of 14 patients with lower urinary tract symptoms caused by the obstruction at the level of the prostatic urethra. The subjects were averagely aged 77.4 +/- 5.1 years. Allium prostatic stent remained in place in the patients for 4.93 +/- 3.17 months, at the average.

  3. A rapid-exchange monorail stent system for salvage of failing femoropopliteal bypass grafts.

    PubMed

    Jahnke, Thomas; Brossmann, Joachim; Walluscheck, Knut; Heller, Martin; Müller-Hülsbeck, Stefan

    2003-08-01

    To analyze the safety and effectiveness of a new monorail stent system for the treatment of failing femoropopliteal bypass grafts. Acute distal occlusions or stenoses of femoropopliteal bypass grafts were treated with balloon-expandable stents (13 or 18-mm diameter) pre-mounted on a monorail balloon catheter system. The delivery system was assessed subjectively for (1). compatibility with the sheath, (2). lesion crossing potential, (3). radiopacity, (4). flexibility of the catheter, (5). adequacy of stent expansion, and (5). balloon refolding. In 8 failing bypass grafts with distal lesions, the delivery system successfully deployed the stent at the desired location. Sheath compatibility, catheter flexibility, lesion crossing, and stent expansion were rated "excellent" by all examiners for the 18-mm device. Radiopacity of the mounted stent was graded "good" before and during positioning, but only "sufficient" following expansion. For this type of lesion, the investigators rated the overall performance of the device superior to conventional "over-the-wire" systems. The monorail balloon-expandable stent delivery system provides rapid introduction of the device over the guidewire, and its low profile facilitates the use of small sheaths to minimize access-site complications.

  4. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Charles Y., E-mail: charles.kim@duke.edu; Tandberg, Daniel J.; Rosenberg, Michael D.

    2012-08-15

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metalmore » stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.« less

  5. [Myocardial ischemia in general medicine and the revolution of coronary stents].

    PubMed

    El-Mourad, M; Merveille, P; Preumont, N

    2014-09-01

    Since Gruentizg's first percutaneous transluminal ballon angioplasty in 1977 in Zurich, percuta. neous coronary intervention evolved significantly in order to overcome the numerous associated complications of each technique. Bare-metal stents (BMS) made their initial appearance followed by three generations of drug-eluting stents (DES). The use of bioabsorbable vascular scaffold stents (BVS) has become more frequent creating a temporary scaffold allowing healing of the endothelium within 2 years. In this article, we discuss the nomenclature of the main intravascular complications linked to percuta. neous coronary intervention such as stent thrombosis (ST), Instent restenosis (ISR), neoatherosclerosis, and stents evolution to overcome these complications. We will finally mention the new technologies of intracoronary imaging such as OCT (Optical Coherence Tomography) having an increasing vital role in percutaneous coronary intervention,

  6. Management for Prostate Cancer Treatment Related Posterior Urethral and Bladder Neck Stenosis With Stents

    PubMed Central

    Erickson, Bradley A.; McAninch, Jack W.; Eisenberg, Michael L.; Washington, Samuel L.; Breyer, Benjamin N.

    2013-01-01

    Purpose Prostate cancer treatment has the potential to lead to posterior urethral stricture. These strictures are sometimes recalcitrant to dilation and urethrotomy alone. We present our experience with the Urolume® stent for prostate cancer treatment related stricture. Materials and Methods A total of 38 men with posterior urethral stricture secondary to prostate cancer treatment were treated with Urolume stenting. Stents were placed in all men after aggressive urethrotomy over the entire stricture. A successfully managed stricture was defined as open and stable for greater than 6 months after any necessary secondary procedures. Results The initial success rate was 47%. After a total of 31 secondary procedures in 19 men, including additional stent placement in 8 (18%), the final success rate was 89% at a mean ± SD followup of 2.3 ± 2.5 years. Four cases (11%) in which treatment failed ultimately requiring urinary diversion (3) or salvage prostatectomy (1). Incontinence was noted in 30 men (82%), of whom 19 (63%) received an artificial urinary sphincter a mean of 7.2 ± 2.4 months after the stent. Subanalysis revealed that irradiated men had longer strictures (3.6 vs 2.0 cm, p = 0.003) and a higher post-stent incontinence rate (96% vs 50%, p <0.001) than men who underwent prostatectomy alone but the initial failure rate was similar (54% vs 50%, p = 0.4). Conclusions Urolume stenting is a reasonable option for severe post-prostate cancer treatment stricture when patients are unwilling or unable to undergo open reconstructive surgery. Incontinence should be expected. The need for additional procedures is common and in some men may be required periodically for the lifetime of the stent. PMID:21074796

  7. Endoscopic ultrasound-guided placement of plastic vs. biflanged metal stents for therapy of walled-off necrosis: a retrospective single-center series.

    PubMed

    Mukai, Shuntaro; Itoi, Takao; Baron, Todd H; Sofuni, Atsushi; Itokawa, Fumihide; Kurihara, Toshio; Tsuchiya, Takayoshi; Ishii, Kentaro; Tsuji, Shujiro; Ikeuchi, Nobuhito; Tanaka, Reina; Umeda, Junko; Tonozuka, Ryosuke; Honjo, Mitsuyoshi; Gotoda, Takuji; Moriyasu, Fuminori; Yasuda, Ichiro

    2015-01-01

    Recently, a novel fully covered and biflanged metal stent (BFMS)dedicated to the drainage of walled-off necrosis(WON) was developed. The aim of this study was to retrospectively evaluate the safety, efficacy, and cost performance of drainage of WON using the novel BFMS compared with a traditional plastic stent. A total of 70 patients with symptomatic WON were treated under endoscopic ultrasound (EUS) guidance. Initial drainage was conducted using the single gateway technique with placement of one or more plastic stents or a single BFMS.If drainage was unsuccessful,direct endoscopic necrosectomy (DEN)was performed. There were no statistically significant differences in rates of technical success, clinical success,and adverse events between plastics stents and BFMS, despite the size of WON in the BFMS group being significantly larger than that in the plastic stent group (105.6 vs. 77.1 mm; P=0.003).The mean procedure times for the first EUS-guided drainage and for re-intervention were significantly shorter in the BFMS group than in the plastic stent group (28.8±7.1 vs. 42.6±14.2, respectively,for drainage, P<0.001; and 34.9±8.5 vs.41.8±7.6, respectively, for re-intervention, P<0.001). There was no statistically significant difference in the total cost between plastic stent and BFMS use in the treatment of WON ($5352vs. $6274; P=0.25). Plastic stents and BFMS were safe and effective for the treatment of WON. In particular,BFMS placement appeared to be preferable for initial EUS-guided drainage and additional reintervention(e.g. DEN) as it reduced the procedure time. Prospective randomized controlled trials are warranted.

  8. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.

    PubMed

    Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2014-03-01

    Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P < 0.001). Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  9. [Feasibility and possibility of Inoue stent graft for thoracic aortic aneurysms].

    PubMed

    Marui, Akira; Kimura, Takeshi; Tazaki, Junichi; Sakata, Ryuzo; Inoue, Kanji

    2011-01-01

    Open surgical repair is a traditional treatment for patients with thoracic aortic aneurysms. Despite recent advances in surgical techniques and anesthetic management, the surgical repair of thoracic aortic aneurysms is still associated with significant mortality and morbidity. Endovascular aneurysm repair of thoracic aortic aneurysms is emerging as an alternative method for repair in selected patients. Although endovascular stent grafting is less invasive than open surgical repair, involvement of branch vessels and precipitous curvature of the aortic arch limits the application of stent grafting. Inoue stent graft system consists of soft nitinol ring-type stent which enables very flexible stent graft, and it can well comply with the precipitous curvature of the aortic arch. The system also provides a stent graft with a side branch to manage the left subclavian artery. This system does not require the surgical revascularization of the left subclavian artery. In this report, we show the feasibility and possibility of Inoue stent graft system to manage the aortic arch aneurysm.

  10. Assessment of vesicoureteral reflux in patients with self-retaining ureteral stents: implications for upper urinary tract instillation.

    PubMed

    Yossepowitch, Ofer; Lifshitz, David A; Dekel, Yoram; Ehrlich, Yaron; Gur, Uri; Margel, David; Livne, Pinhas M; Baniel, Jack

    2005-03-01

    Conservative treatment of upper urinary tract tumors has been popularized during the last decade. Like in bladder cancer management, localized adjuvant therapy has been advocated to reduce the risk of disease recurrence or progression. In this study we tested the feasibility of creating vesicoureteral reflux (VUR) using a Double-J stent (Medical Engineering Corp., New York, New York) as a measure of efficacy for intravesical adjuvant treatment of the ureter and renal collecting system. The cohort included 100 consecutive patients in whom a Double-J stent was inserted for renal obstruction. All the patients underwent cystography in the supine position by retrograde filling of the bladder with a 50% dilute solution of 300 mgI/ml iopromide in serial increments of 50 ml up to a maximum of 350 ml. A total of 41 patients underwent cystography immediately following stent insertion (early group) and 59 patients with indwelling stents underwent cystography before further endourological intervention (late group). The presence of VUR and the level along the ureter and renal collecting system were assessed fluoroscopically. Overall VUR was detected in 56 patients (56%), specifically 11 of the 41 (27%) in the early group and 45 of the 59 (76%) in the late group (p <0.001). There was no correlation between stent diameter or length and VUR, or between patient sex, age or particular side and the likelihood of reflux. Mean minimal intravesical volume required to obtain reflux was 171 +/- 11 ml, which was significantly higher in the early (255 +/- 21 ml) than in the late (146 +/- 11 ml) cystogram group. In 24 of the 56 patients (43%) with VUR, there was complete visualization of the entire ureter and renal collecting system. However, 15 patients (26%) had opacified renal pelves and calices without concomitant visualization of the ureters, whereas 7 patients (31%) had reflux to the ureter without opacification of the renal pelvis. VUR is not a guaranteed consequence of Double-J stent placement. Therefore, when upper urinary tract instillation with the Double-J technique is considered, a cystogram should be performed first to confirm the occurrence of reflux, determine the intravesical volume required to induce reflux and ascertain that the pertinent section of the ureter or pelvicaliceal system from which the tumor was initially removed is opacified during study. An interval that remains to be defined should be allowed between stent insertion and VUR assessment.

  11. Indications and applications of arterial stents for stroke prevention in atherosclerotic intracranial stenosis.

    PubMed

    Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L

    2010-01-01

    Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.

  12. Technical feasibility and revision efficacy of the sequential deployment of endoscopic bilateral side-by-side metal stents for malignant hilar biliary strictures: a multicenter prospective study.

    PubMed

    Lee, Tae Hoon; Park, Do Hyun; Lee, Sang Soo; Choi, Hyun Jong; Lee, Jun Kyu; Kim, Tae Hyeon; Kim, Jong Hyeok; Jeong, Seok; Park, Sang-Heum; Moon, Jong Ho

    2013-02-01

    Theoretically, the side-by-side bilateral placement of metal stents may be technically easier than stent-in-stent bilateral placement in stent revision. However, side-by-side placement can be technically challenging, as the deployment of the first stent can preclude the passage of the second stent. We explored the technical feasibility and revision efficacy of endoscopic bilateral side-by-side stent placement for malignant hilar biliary strictures. Forty-four patients with Bismuth type II or higher malignant hilar biliary strictures were enrolled in seven academic tertiary referral centers. Endoscopic placement of side-by-side bilateral metal stents with 7F thin delivery shaft was performed. The outcome measurements were the technical and functional success, adverse events, endoscopic revision success rate, and stent patency. Overall, the technical and functional success rates were 91 % (40/44), and 98 % (39/40), respectively. Two of the failed patients were converted successfully with subsequent contralateral stent-in-stent placement, and the other patients underwent percutaneous intervention. Early stent-related adverse events occurred in 10 %. The endoscopic revision rate due to stent malfunction during follow-up (median: 180 days) was 45 % (18/40; tumor ingrowth in 4 and in-stent sludge impaction/stone formation in 14 patients). The endoscopic revision success rate was 92 % (12/13). Five patients with comorbidity underwent initial percutaneous intervention. The median survival and stent patency periods were 180 and 157 days, respectively. The sequential placement of a metal stent with a 7F thin delivery shaft in bilateral side-by-side procedures may be feasible and effective for malignant hilar biliary strictures and for endoscopic stent revision.

  13. Immediate, short‐, and long‐term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome

    PubMed Central

    Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth

    2018-01-01

    Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368

  14. Immediate, short-, and long-term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome.

    PubMed

    Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth

    2018-03-01

    Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  15. Sequential Stenting for Extensive Malignant Airway Stenosis

    PubMed Central

    Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Tei, Keiko; Yamamoto, Ryoji

    2014-01-01

    Purpose: Malignant airway stenosis extending from the bronchial bifurcation to the lower lobar orifice was treated with airway stenting. We herein examine the effectiveness of airway stenting for extensive malignant airway stenosis. Methods: Twelve patients with extensive malignant airway stenosis underwent placement of a silicone Dumon Y stent (Novatech, La Ciotat, France) at the tracheal bifurcation and a metallic Spiral Z-stent (Medico’s Hirata, Osaka, Japan) at either distal side of the Y stent. We retrospectively analyzed the therapeutic efficacy of the sequential placement of these silicone and metallic stents in these 12 patients. Results: The primary disease was lung cancer in eight patients, breast cancer in two patients, tracheal cancer in one patient, and thyroid cancer in one patient. The median survival period after airway stent placement was 46 days. The Hugh–Jones classification and performance status improved in nine patients after airway stenting. One patient had prolonged hemoptysis and died of respiratory tract hemorrhage 15 days after the treatment. Conclusion: Because the initial disease was advanced and aggressive, the prognosis after sequential airway stent placement was significantly poor. However, because respiratory distress decreased after the treatment in most patients, this treatment may be acceptable for selected patients with extensive malignant airway stenosis. PMID:25273272

  16. Polyflex expandable stents in the treatment of esophageal disease: initial experience.

    PubMed

    Pennathur, Arjun; Chang, Andrew C; McGrath, Kevin M; Steiner, Gregory; Alvelo-Rivera, Miguel; Awais, Omar; Gooding, William E; Christie, Neil A; Gilbert, Sebastien; Landreneau, Rodney J; Luketich, James D

    2008-06-01

    The new generation of expandable plastic esophageal stents (Polyflex; Boston Scientific, Natick, MA), combine the features of plastic and self-expanding metallic stents. The main objective of this study is to evaluate our initial experience with Polyflex expandable stents in the treatment of esophageal disease from two institutions. A total of 58 Polyflex stents were placed in 38 patients over a two-year period. There were 24 men and 14 women, with a median age of 63 years (range, 25 to 83). The most common indication for placement was an esophageal stricture in 25 patients (66%); other causes included leak in 8 (21%) and tracheoesophageal fistula (TEF) in 5 (13%). We evaluated the hospital course, complications, and outcomes. The median postoperative stay was one day. Complications included migration in 38 stents (63%) (28 patients; 73%), retrosternal chest discomfort in nine, reflux in four, airway obstruction in one, and food impaction in three. Continued leak or a persistent TEF occurred in five patients (38%). Reintervention was required predominantly due to migration of the stent at a mean interval of 46 days (range, 1 to 353). Patients with dysphagia improved significantly with dysphagia scores (1 = no dysphagia; 5 = unable to swallow saliva) improving from 3.44 to 2.15 (p < 0.0001). Polyflex stents were effective in the relief of dysphagia due to strictures. They were less effective in esophageal perforations or leaks. Their primary disadvantage is a high migration rate and further improvements in design are required to decrease this high incidence of migration.

  17. Measurement and Comparison of Mechanical Properties of Nitinol Stents

    NASA Astrophysics Data System (ADS)

    Hanus, Josef; Zahora, Jiri

    2005-01-01

    The self expandable Nitinol stents or stentgrafts are typically used for miniinvasive treatment of stenosis and aneurysms in the cardiovascular system. The minimal traumatisation of the patient, shorter time of hospitalization are typical advantages of these methods. More than ten years of experience has yielded also important information about the performance of stents in interaction with biological system and the possible problems related with it. The leakage or the shift of stent are some typical disadvantages, that can be related among other in the construction of the stent. The problem is that the mechanical properties, dimensions and the dynamical properties of the stent do not exactly correspond to the properties of the vessel or generally of tissue where this stent is introduced. The measurement, the description and the comparison of the relations between the mechanical properties of stents and tissues can be one of the possible ways to minimize these disadvantages. The developed original computer controlled measuring system allows the measurement of mechanical properties of stents, the measurement of strain-stress curves or simulation of interaction of the stent and vessel for exactly defined hemodynamic conditions. We measured and compared the mechanical parameters of different selfexpandable Nitinol stents, which differed in geometry (radius and length), in the type of construction (number of branches and rising of winding) and in the diameter of used wire. The results of measurements confirmed the theoretical assumptions that just the diameter of the Nitinol wire significantly influences the rigidity and the level of compressibility of the stent as well. A compromise must be found between the required rigidity of the stent and the minimal size of the delivery system. The exact description of the relation between the mechanical properties and geometry and construction of the stents enables to design the stent to fit the patient and it is expected that this access improves the efficiency of treatment. The results of measurement are also necessary for the design and identification of the parameters of the models of the stents.

  18. The SPIRIT V study: a clinical evaluation of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions.

    PubMed

    Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra

    2011-02-01

    The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice) trials. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm.

    PubMed

    Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua

    2015-05-01

    The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    PubMed

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  1. Initial experience with a new biodegradable airway stent in children: Is this the stent we were waiting for?

    PubMed

    Antón-Pacheco, Juan L; Luna, Carmen; García, Enrique; López, María; Morante, Rocío; Tordable, Cristina; Palacios, Alba; de Miguel, Mónica; Benavent, Isabel; Gómez, Andrés

    2016-06-01

    To report our experience with a new type of biodegradable airway stent in the setting of severe tracheobronchial obstruction in children. We conducted a retrospective and prospective (since June 2014) study of pediatric patients with severe airway obstruction treated with biodegradable stents in our institution between 2012 and 2015. The following data were collected: demographics, indication for stenting, bronchoscopic findings, insertion technique complications, clinical outcome, stent related complications, re-stenting, and time of follow-up. Thirteen custom-made polydioxanone stents were placed in four infants (mean age, 4 months) with severe tracheobronchial obstruction: tracheomalacia (two patients), bronchomalacia (1), and diffuse tracheal stenosis (1). All the stents were bronchoscopically inserted uneventfully. Immediate and maintained clinical improvement was observed in every case. No major stent related complications have occurred and only mild or moderate granulation tissue was observed during surveillance bronchoscopy. Two patients required repeated stenting as expected. All the patients are alive and in a good respiratory condition with a follow-up ranging from 5 to 40 months. Biodegradable airway stents seem to be safe, effective, and cause fewer complications than other types of stents. They can be an alternative to the classic metallic or plastic stents for severe tracheal stenosis or malacia in small children. More experience is needed in order to establish the definite clinical criteria for their use in pediatric patients. Pediatr Pulmonol. 2016;51:607-612. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  2. Malignant biliary disease: percutaneous interventions.

    PubMed

    Morgan, R A; Adam, A N

    2001-09-01

    Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company

  3. Pneumoperitoneum Caused by Transhepatic Air Leak After Metallic Biliary Stent Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jei Hee; Lee, Deok Hee; Yu, Jeong-Sik

    2000-11-15

    A self-expanding metallic biliary stent was placed for palliation of a common bile duct obstruction in a 68-year-old male with unresectable pancreatic head cancer 3 days after initial percutaneous right transhepatic catheter decompression. The stent crossed the ampulla of Vater. Three days later, the stent was balloon-dilated and the percutaneous access was removed. At removal, a small contrast leak from the transhepatic tract was seen. Three days later, pneumoperitoneum was found with symptoms of peritoneal irritation and fever. A widely open sphincter of Oddi caused by the metallic stent, accompanied by delayed sealing of the transhepatic tract, may have causedmore » the air and bile leakage into the peritoneal space. This case shows that pneumoperitoneum may occur without ductal tear or bowel injury, with a biliary stent crossing the ampulla of Vater.« less

  4. The use of expandable metallic airway stents for tracheobronchial obstruction in children.

    PubMed

    Filler, R M; Forte, V; Fraga, J C; Matute, J

    1995-07-01

    Expandable metallic angioplasty stents (Palmaz stent) have been implanted in the trachea and/or bronchi of seven children. Three children had severe tracheal stenosis after tracheoplasty for congenital tracheal stenosis repair, and four had tracheomalacia or bronchomalacia with or without vascular compression. The mean age at stenting was 9.7 months (range, 2 to 15 months). Balloon expandable stents were inserted into the trachea or bronchus through a 3.5-mm bronchoscope under fluoroscopic control. Initially a single tracheal stent was used for all patients except for one with obstruction in the trachea and both bronchi, in whom three stents were implanted. Three children had recurrent airway obstruction 1 month later; one was cured with a second stent; one child died 1 year later; and the other is being treated for heart disease. The others have no serious respiratory problems. The stents in all have been in place for 1 to 25 (mean, 11) months. No immediate complications were noted. Early and late bronchoscopy showed incomplete epithelialization of the stent and patches of granulation tissue on it. Two stents were removed bronchoscopically, one at the completion of treatment for tracheomalacia and the other at the time of recurrent airway obstruction. This preliminary experience indicates that expandable metallic stents have a useful role in the treatment of selected lower airway obstructions.

  5. Traumatic cervical internal carotid artery pseudoaneurysm in a child refractory to initial endovascular treatment: case report and technical considerations.

    PubMed

    Wang, Arthur; Santarelli, Justin G; Stiefel, Michael F

    2016-12-01

    Optimal management of extracranial carotid artery dissections (eCAD) in pediatric patients is not well documented, and endovascular interventions are rarely reported. A 10-year-old girl sustained multiple systemic injuries in a motor vehicle accident, including an eCAD with pseudoaneurysm. She initially failed both aspirin and endovascular stenting with progressive enlargement of a traumatic cervical carotid pseudoaneurysm and stenosis. Second-stage endovascular stent placement with coiling resulted in successful occlusion of the pseudoaneurysm. At 30-month imaging follow-up, the parent vessel remained patent with no evidence of the pseudoaneurysm. In the setting of poly-trauma, management of eCAD can be complex especially in the pediatric population. There is little data on the endovascular treatment of eCAD in children. Failed endovascular therapies are extremely rare. Our report supports surveillance imaging as repeat endovascular treatment may be necessary.

  6. Development and evaluation of a centralised computerised registry for ureteric stents: completing the audit cycle.

    PubMed

    Davis, N F; Murray, G; O'Connor, T; Browne, C; MacCraith, E; Galvin, D; Mulvin, D; Quinlan, D; Lennon, G

    2017-11-01

    A forgotten ureteric stent may result in severe renal impairment leading to nephrectomy. To compare the effectiveness of a centralised computerised registry for monitoring ureteric stent activity with a previously established theatre stent logbook system. This prospective audit was performed in two 9-monthly intervals. During the first interval, insertion/removal of a ureteric stent was documented in a specific theatre stent logbook. In the second interval, an electronic centralised computerised registry was developed to document insertion/removal of a ureteric stent onto an accessible hospital server. A computerised traffic-light system was also developed to identify patients with an indwelling stent for >3 months. The primary outcome variable was the number of prolonged indwelling ureteric stents in both groups. During the first time interval, 188 ureteric stents were inserted and 182 (96%) were removed or changed. Six (4%) patients underwent insertion of a ureteric stent for a prolonged period of time (>6 months). This subgroup required complex endourological intervention for stent removal due to encrustation. During the second time interval, 157 ureteric stents were inserted and all patients had their stent removed or changed within 6 months. No patients in this group were lost to follow-up. This study demonstrates that a centralised computerised ureteric stent registry is superior to a conventional logbook for monitoring ureteric stent activity. We propose the introduction a centralised nationalised ureteric stent registry for eliminating the potential for prolonged or forgotten ureteric stents.

  7. Perioperative antiplatelet management in patients with coronary artery stenting.

    PubMed

    Tandar, Anwar; Velagapudi, Krishna N; Wilson, Brent D; Boden, William E

    2012-04-01

    Coronary artery disease is the primary cause of mortality in men and women in the United States. Transcatheter coronary intervention is the mainstay of treatment for patients with acute coronary artery disease presentations and patients with stable disease. Although percutaneous intervention initially only included balloon angioplasty, it now typically involves the placement of intracoronary stents. To overcome the limitations of bare-metal stents, namely in-stent restenosis, stents have been developed that remove pharmaceuticals that reduce neointimal hyperplasia and in-stent restenosis. However, these pharmaceutical agents also delay stent endothelialization, posing a prolonged risk of in situ thrombosis. Placement of an intracoronary stent (eg, bare-metal or drug-eluting stent) requires dual antiplatelet therapy to prevent the potentially life-threatening complication of stent thrombosis. The optimal duration of dual antiplatelet therapy following stent placement is unknown. This article discusses the factors to be considered when deciding when dual antiplatelet therapy can be safely discontinued. Unfortunately, in the hospital setting, this decision to interrupt dual antiplatelet therapy frequently must be made shortly after stent placement because of unanticipated surgical procedures or other unforeseen complications. The decision of when dual antiplatelet therapy can be safely interrupted needs to be individualized for each patient and involves factoring in the type of stent; the location and complexity of the lesion stented; post-stent lesion characteristics; the amount of time since stent placement; and the antiplatelet regimen currently in use, along with its implication for bleeding during the proposed procedure. Having a protocol in place, such as the protocol described in this article, can help guide this decision-making process and avoid confusion and potential error.

  8. Treatment of benign and malignant tracheobronchial obstruction with metal wire stents: experience with a balloon-expandable and a self-expandable stent type.

    PubMed

    Rieger, Johannes; Hautmann, Hubert; Linsenmaier, Ulrich; Weber, Cristoph; Treitl, Markus; Huber, Rudolf Maria; Pfeifer, Klaus-Jürgen

    2004-01-01

    Over the last few years various types of metal wire stents have been increasingly employed in the treatment of both malignant and benign tracheobronchial obstruction. To date, however, few studies have investigated the in vivo properties of different stent types. We implanted 26 balloon-expandable tantalum Strecker stents (18 patients) and 18 self-expandable Wallstents (16 patients) into the tracheobronchial system of 30 patients with combined stenting in 4 patients. Mean age was 51 years (range: 0.5-79 years). Malignant disease was present in 23 patients, benign disease in seven patients. Both patients and individual stents were monitored clinically and radiographically. The probability of stents remaining within the tracheobronchial system, and of their remaining undislocated and uncompressed was calculated using Kaplan-Meier analysis for both stent types. Average stent follow-up time was 112 days until explantation and 115 days until patients' death or discharge. Kaplan-Meier analysis revealed a higher probability for the Wallstent to remain within the tracheobronchial system. Dislocation and compression occurred more rarely. Explantation, however, if desired, was more difficult compared to the Strecker stent. The Wallstent also led to the formation of granulation tissue, especially at the proximal stent end, frequently requiring reintervention. Both stent types proved to be effective therapeutic options in the management of obstructive tracheobronchial disease. The mechanical properties of the Strecker stent seem to be less favorable compared to the Wallstent but removal is easy. For benign disease, however, the Wallstent reveals limitations due to significant side effects.

  9. Optimization of stent implantation using a high pressure inflation protocol.

    PubMed

    Vallurupalli, Srikanth; Bahia, Amit; Ruiz-Rodriguez, Ernesto; Ahmed, Zubair; Hakeem, Abdul; Uretsky, Barry F

    2016-01-01

    High-pressure inflation is the universal standard for stent deployment but a specific protocol for its use is lacking. We developed a standardized "pressure optimization protocol" (POP) using time to inflation pressure stability as an endpoint for determining the required duration of stent inflation. The primary study purpose was to determine the stent inflation time (IT) in a large patient cohort using the standardized inflation protocol, to correlate various patient and lesion characteristics with IT, and ascertain in an in vitro study the time for pressure accommodation within an inflation system. Six hundred fifteen stent implants in 435 patients were studied. Multivariate analysis was performed to determine predictors of longer ITs. In an in vitro study, various stents and balloons were inflated in air to determine the pressure accommodation time of the inflation system. The mean stent IT was 104 ± 41 sec (range 30-380 sec). Stent length was the only predictor of prolonged stent inflation. The "accommodation time" in vitro of the stent inflation system itself was 33 ± 24 sec. The protocol was safe requiring premature inflation termination in <3% of stent implants. No serious adverse events occurred. Achieving stable inflation pressure requires on average over 100 sec and may require several minutes in individual cases. Stent length increases IT. These results suggest that the widespread practice of rapid inflation/deflation may not be sufficient to fully expand the stent and that the use of a pressure stability protocol will allow for safe, predictable, and more complete stent deployment. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  10. Comparison of Flow Characteristics of Novel Three-Dimensional Printed Ureteral Stents Versus Standard Ureteral Stents in a Porcine Model.

    PubMed

    Del Junco, Michael; Yoon, Renai; Okhunov, Zhamshid; Abedi, Garen; Hwang, Christina; Dolan, Benjamin; Landman, Jaime

    2015-09-01

    We compared the flow characteristics of novel three-dimensional (3D) printed ureteral stents with four conventional double-pigtail stents in an ex vivo porcine model. In six ex vivo porcine urinary systems with kidneys and ureters intact, we deployed a 5F occlusion catheter in an interpolar calix. We tested each system with antegrade irrigation with a 0.9% saline bag placed 35 cm above the renal pelvis. We evaluated four standard stents (6F Universa® Soft, 7F Percuflex,™ 7/10F Applied Endopyelotomy, 8.5F Filiform Double Pigtail) and compared them with a 9F 3D printed prototype stent. For each stent, we measured the total, extraluminal, and intraluminal flow rates. The mean total flow rates for 3D printed stents were significantly higher than the 6F, 7F, and 7/10F stents (P<0.05). No significant difference was seen in the total flow rate for the 3D printed stent and the 8.5F stent. The mean extraluminal flow rates for the 3D stents were similar to those of 7F stents, but significantly lower than 6F stents (P<0.001) and 8.5F stents (P<0.05) and higher than 7/10F stents (P<0.001). The mean intraluminal flow rates for the 3D printed stents were significantly higher than the 6F, 7F, 7/10F, and 8.5F stents (P<0.05). In this pilot study, 3D printed stents manifested a mean total flow rate comparable to the flow rates of contemporary stents. Continued advances in technology and material may permit functionally feasible 3D printed ureteral stents.

  11. Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes

    PubMed Central

    Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.

    2016-01-01

    Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614

  12. Use of the Viatorr Expanded Polytetrafluoroethylene-Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation in Children: Initial Clinical Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mermuys, Koen; Maleux, Geert, E-mail: geert.maleux@uzleuven.be; Heye, Sam

    2008-07-15

    Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent untilmore » the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.« less

  13. Airway stent complications: the role of follow-up bronchoscopy as a surveillance method

    PubMed Central

    Labaki, Wassim; Yu, Diana H.; Salwen, Benjamin; Gilbert, Christopher; Schneider, Andrea L. C.; Ortiz, Ricardo; Feller-Kopman, David; Arias, Sixto; Yarmus, Lonny

    2017-01-01

    Background Airway stenting has become an integral part of the therapeutic endoscopic management of obstructive benign and malignant central airway diseases. Despite increased use of airway stents and frequent stent-associated complications, no clear guidelines for surveillance and maintenance exist. This study aim is to elucidate predictive factors associated with development of stent complications, as well as an optimal surveillance period for follow-up bronchoscopy for early detection and possible prevention of stent-associated complications. Methods Retrospective cohort study of all patients who underwent airway stent placements at our institution from April 2010 to December 2013 for benign and malignant airway diseases. Metallic, silicone (straight, Y stent, T-tube) and hybrid stents were included in the study. Stent complications were analyzed at the time of follow-up bronchoscopy performed four to six weeks after initial stent placement or earlier if patients became symptomatic. Results The study included 134 patients of which 147 stents were placed. Follow-up bronchoscopy was performed in 94 patients. Symptomatic status at the time of follow-up bronchoscopy was not associated with stent complications [odds ratio (OR) =1.88; 95% CI: 0.79–4.45; P=0.15]. Patient age, sex, indication for stent placement, and stent location, were not associated with development of complications (all P>0.05). Compared to all other stents, hybrid stents were more likely to migrate (OR =6.60; 95% CI: 2.16–20.2; P=0.001) or obstruct by secretions (OR =2.53; 95% CI: 1.10–5.84; P=0.03). There were no complications associated with surveillance bronchoscopy. Conclusions Surveillance bronchoscopy within 4 to 6 weeks of stent placement may be useful for early detection of complications and their subsequent management, regardless of symptomatic status and indication for stent placement. Prospective multicenter studies are needed to compare optimal surveillance methods and the impact on patient mortality, morbidity and healthcare costs. PMID:29268534

  14. Long-Term Efficacy of Percutaneous Internal Plastic Stent Placement for Non-anastomotic Biliary Stenosis After Liver Transplantation.

    PubMed

    Lee, Eun Sun; Han, Joon Koo; Baek, Ji-Hyun; Suh, Suk-Won; Joo, Ijin; Yi, Nam-Joon; Lee, Kwang-Woong; Suh, Kyung-Suk

    2016-06-01

    We aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents. This study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34-68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based on clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29-9.95 years). We assessed treatment success rate and patient and graft survival times. During the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00-9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42-4.25). Percutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.

  15. Endoscopic Stent Placement in the Palliation of Malignant Biliary Obstruction

    PubMed Central

    2011-01-01

    Biliary drainage with biliary stent placement is the treatment of choice for palliation in patients with malignant biliary obstruction caused by unresectable neoplasms. In such patients, the endoscopic approach can be initially used with percutaneous radiological intervention. In patients with unresectable malignant distal bile duct obstructions, endoscopic biliary drainage with biliary stent placement has now become the main and least invasive palliative modality, which has been proven to be more effective in >80% of cases with lower morbidity than surgery, and perhaps may provide a survival benefit. In patients with unresectable malignant hilar obstruction, the endoscopic approach for biliary drainage with biliary stent placement has also been considered as the treatment of choice. There is still a lack of clear consensus on the use of covered versus uncovered metal stents in malignant distal bile duct obstructions and plastic versus metal stents and unilateral versus bilateral drainage in malignant hilar obstructions. PMID:22741117

  16. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    PubMed

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. 76 FR 56200 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-12

    ... Stent. The ZILVER-PTX Stent is a self-expanding nitinol stent coated on its outer surface with the... millimeter. The ZILVER-PTX Stent is available in diameters ranging from 5 to 10 millimeters (mm) and lengths... deployment, the ZILVER-PTX Stent expands to establish and maintain patency in the stented region. The...

  18. OCT assisted identification of the grade of encrustation of urologic catheters

    NASA Astrophysics Data System (ADS)

    Sroka, Ronald; Püls, Michaela; Stepp, Herbert; Zilinberg, Katja; Bader, Markus; Weidlich, Patrick

    2013-06-01

    Introduction: Ureteric stenting is a commonly used endourologic procedure for temporary and long-term drainage of an obstructed upper urinary tract. The indication for ureteric stenting is obstruction due to intrinsic (intraureteral stones, strictures, or tumors) or extrinsic (for example compressing pelvic or retroperitoneal mass) causes. Despite the fact that stents do certainly have proven benefits in all fields of urology, there are potential morbidities. The most common problem of indwelling ureteral stents is infection. As foreign body in the urinary system, stents act as a nidus for bacteria colonization, crystallization and encrustation. Bacteria induced biofilm formation predisposes for the crystallization of lithogenic salts, such as calcium-phosphate, calcium-oxalate, magnesium-phosphate on the surface initiating stent encrustation. It was the objective of this study to evaluate whether optical coherence tomography (OCT) using both the surface and the endoluminal technique is feasible to investigate the locations and degree of encrustation process in clinically used ureteral stents. Patients and methods: After removal from patients, fourteen polyurethane JJ stents were investigated. A fresh JJ served as a control. The external surfaces were examined using an endoscopic surface OCT whereas the intraluminal surfaces were investigated by an endoluminal radial OCT device. The focus was on detection of encrustation or crystalline sedimentation. Results: In 12 female and 2 male patients, the median indwelling time of the ureteral catheter was 100 days (range 19- 217). Using the endoluminal OCT, the size and grade of intraluminal encrustation could be expressed as a percentage relating to the open lumen of the reference stent. The maximum encrustation observed resulted in a remaining unrestricted lumen of 15-35% compared to the reference. The luminal reduction caused by encrustation was significantly higher at the proximal end of the ureteral stent as compared to its distal part. The extraluminal OCT-investigations facilitated the characterization of extraluminal encrustation. Conclusion: OCT techniques were feasible and facilitated the detection of encrustation of double pigtail catheters on both the extra and intra luminal surface. Quantitative expression of the degree of intraluminal encrustation could be achieved, with the most dense and thickened occurrence of intraluminal incrustation in the upper curl of the JJ stent.

  19. Minimally invasive glaucoma surgery as primary stand-alone surgery for glaucoma.

    PubMed

    Kerr, Nathan M; Wang, Jing; Barton, Keith

    2017-05-01

    Recently, many new devices and procedures have been developed to lower intraocular pressure in a less invasive and purportedly safer manner than traditional glaucoma surgery. These new devices might encourage an earlier transition to surgery and reduce the long-term commitment to topical glaucoma medications with their associated compliance and intolerance issues. Although often seen as an adjunct to cataract surgery, a growing body of evidence suggests that primary minimally invasive glaucoma surgery may be a viable initial treatment option. New studies have shown that primary ab interno trabeculectomy (Trabectome, NeoMedix Inc., Tustin, CA, USA), trabecular micro-bypass stent insertion (iStent and iStent Inject, Glaukos Corporation, Laguna Hills, CA, USA), canalicular scaffolding (Hydrus, Invantis Inc., Irvine CA, USA), the ab interno gel Implant (XEN, Allergan, Dublin, Ireland) or supraciliary stenting (CyPass Micro-Stent, Alcon, Fort Worth, TX, USA) may lower the lowering intraocular pressure and/or topical medication burden in phakic or pseudophakic patients with glaucoma. This effect seems to last at least 12 months but reliable cost-effectiveness and quality of life indicators have not yet been established by investigator-initiated randomized trials of sufficient size and duration. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  20. Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction.

    PubMed

    Inatomi, Osamu; Bamba, Shigeki; Shioya, Makoto; Mochizuki, Yosuke; Ban, Hiromitsu; Tsujikawa, Tomoyuki; Saito, Yasuharu; Andoh, Akira; Fujiyama, Yoshihide

    2013-02-14

    Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy.

  1. Novel biliary self-expanding metal stents: indications and applications.

    PubMed

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  2. Expansion of the Multi-Link Frontier™ Coronary Bifurcation Stent: Micro-Computed Tomographic Assessment in Human Autopsy and Porcine Heart Samples

    PubMed Central

    Kralev, Stefan; Haag, Benjamin; Spannenberger, Jens; Lang, Siegfried; Brockmann, Marc A.; Bartling, Soenke; Marx, Alexander; Haase, Karl-Konstantin; Borggrefe, Martin; Süselbeck, Tim

    2011-01-01

    Background Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. Methodology/Principal Findings Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm2 vs. 12.84±1.38 mm2, p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). Conclusions/Significance Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion. PMID:21814552

  3. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.

    PubMed

    Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma

    2015-07-01

    The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.

  4. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less

  5. Clinical Results and Problems of Percutaneous Transluminal Angioplasty and Stenting for Extracranial Internal Carotid Stenoses

    PubMed Central

    Tsuura, M.; Terada, T.; Masuo, O.; Matsumoto, H.; Itakura, T.; Hyoutani, G.; Nakamura, Y.; Moriwaki, H.; Hayashi, S.

    2001-01-01

    Summary 110 patients with extracranial ICA stenosis were treated by PTA or stenting. In 21 of 55 cases of only PTA and in 40 of 55 cases of stenting, we used our blocking balloon systems to prevent distal embolism. The morbidity and the mortality rates were 5.4% and 0%, respectively. There was only one embolic complication in cases of PTA or stenting where blocking balloon systems were used. In contrast, distal embolism occurred in 3 of 34 cases of PTA without blocking balloon systems (one symptomatic case) and in 4 of 15 cases of stenting without blocking balloon systems (3 symptomatic cases). Our blocking balloon catheter system is a useful device to reduce the risk of symptomatic distal embolism. PMID:20663375

  6. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    PubMed Central

    Bishu, Kalkidan; Armstrong, Ehrin J

    2015-01-01

    Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints) and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed. PMID:26203255

  7. Angiographic and Interventional Management for a Esophagopericardial Fistula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Keng, E-mail: zjwukeng@hotmail.com; You, Qiong, E-mail: qiong_you@yahoo.cn; He, Song-Jian

    2013-06-19

    We reported a case of a 78-year-old patient with esophagopericardial fistula who was referred for angiographic and interventional management. Emergent implantation of the esophageal stent could not lengthen or even save the patient’s life. One week later, the patient died of multiple organ failure, which was probably from formation of granulation tissue and stent migration. Therefore, if the inflammatory to the esophagopericardial fistula had been better controlled initially, and the implantation of the esophageal stent delayed, our patient would have survived.

  8. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    PubMed

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Initial study of sediment antagonism and characteristics of silver nanoparticle-coated biliary stents in an experimental animal model.

    PubMed

    Tian, Yigeng; Xia, Mingfeng; Zhang, Shuai; Fu, Zhen; Wen, Qingbin; Liu, Feng; Xu, Zongzhen; Li, Tao; Tian, Hu

    2016-01-01

    Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs) and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice. AgNP-coated Teflon biliary stents were prepared by chemical oxidation-reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD); animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA), and the composition of sediment was assayed by Fourier-transform infrared (FTIR) spectroscopy. Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5-6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR spectroscopy identified stent sediment components including bilirubin, cholesterol, bile acid, protein, calcium, and other substances. AgNP-coated biliary stents resisted sediment accumulation in this canine model of obstructive jaundice caused by ligation of the CBD.

  10. Initial study of sediment antagonism and characteristics of silver nanoparticle-coated biliary stents in an experimental animal model

    PubMed Central

    Tian, Yigeng; Xia, Mingfeng; Zhang, Shuai; Fu, Zhen; Wen, Qingbin; Liu, Feng; Xu, Zongzhen; Li, Tao; Tian, Hu

    2016-01-01

    Objective Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs) and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice. Methods AgNP-coated Teflon biliary stents were prepared by chemical oxidation–reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD); animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA), and the composition of sediment was assayed by Fourier-transform infrared (FTIR) spectroscopy. Results Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5–6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR spectroscopy identified stent sediment components including bilirubin, cholesterol, bile acid, protein, calcium, and other substances. Conclusion AgNP-coated biliary stents resisted sediment accumulation in this canine model of obstructive jaundice caused by ligation of the CBD. PMID:27217749

  11. Covered Biodegradable Stent: New Therapeutic Option for the Management of Esophageal Perforation or Anastomotic Leak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerna, Marie; Koecher, Martin, E-mail: martin.kocher@seznam.cz; Valek, Vlastimil

    2011-12-15

    Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during amore » balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.« less

  12. Outcomes of secondary self-expandable metal stents versus surgery after delayed initial palliative stent failure in malignant colorectal obstruction.

    PubMed

    Yoon, Jin Young; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2013-01-01

    When re-intervention is required due to an occluded first colorectal self-expanding metal stent for malignant colorectal obstruction, serious controversies exist regarding whether to use endoscopic re-stenting or surgery. To compare the clinical outcomes in patients who underwent stent re-insertion versus palliative surgery as a second intervention. A total of 115 patients who received either self-expandable metal stent (SEMS) insertion or palliative surgery for treatment of a second occurrence of malignant colorectal obstruction after the first SEMS placement were retrospectively studied between July 2005 and December 2009. The median overall survival (8.2 vs. 15.5 months) and progression-free survival (4.0 vs. 2.7 months) were not significantly different between the stent and surgery groups (p = 0.895 and 0.650, respectively). The median lumen patency in the stent group was 3.4 months and that in the surgery group was 7.9 months (p = 0.003). The immediate complication rate after second stent insertion was 13.9% and late complication rate was observed in 12 of 79 (15.2%) patients. There was no mortality related to the SEMS procedure. The complication and mortality rates associated with palliative surgery were 3.5% (2/57) and 12.3% (7/57), respectively. Although there is no significant difference in the overall survival between stenting and surgery, a secondary stent insertion had a lower mortality rate despite a shorter duration of temporary colorectal decompression compared to that of palliative surgery.

  13. Anatomic bifurcated reconstruction of chronic bilateral innominate-superior vena cava occlusion using the Y-stenting technique.

    PubMed

    Amin, Parth; Sharafuddin, Mel J; Laurich, Chad; Nicholson, Rachael M; Sun, Raphael C; Roh, Simon; Kresowik, Timothy F; Sharp, William J

    2012-02-01

    This article presents the case of a 42-year-old man who presented with superior vena cava (SVC) syndrome due to fibrosing mediastinitis with multiple failed attempts at recanalization. We initially treated him with unilateral sharp needle recanalization of the right innominate vein into the SVC stump followed by stenting. Although his symptoms improved immediately, they did not completely resolve. Six months later, he returned with worsening symptoms, and venography revealed in-stent restenosis. The patient requested simultaneous treatment on the left side. The right stent was dilated, and a 3-cm-long occlusion of the left innominate vein was recanalized, again using sharp needle technique, homing into the struts of the right-sided stent. Following fenestration of the stent, a second stent was deployed from the left side into the SVC, and the two Y limbs were sequentially dilated to allow a true bifurcation anatomy (figure). The patient had complete resolution of his symptoms and continues to do well 6 months later. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  14. Endovascular Gene Delivery from a Stent Platform: Gene- Eluting Stents

    PubMed Central

    Fishbein, Ilia; Chorny, Michael; Adamo, Richard F; Forbes, Scott P; Corrales, Ricardo A; Alferiev, Ivan S; Levy, Robert J

    2015-01-01

    A synergistic impact of research in the fields of post-angioplasty restenosis, drug-eluting stents and vascular gene therapy over the past 15 years has shaped the concept of gene-eluting stents. Gene-eluting stents hold promise of overcoming some biological and technical problems inherent to drug-eluting stent technology. As the field of gene-eluting stents matures it becomes evident that all three main design modules of a gene-eluting stent: a therapeutic transgene, a vector and a delivery system are equally important for accomplishing sustained inhibition of neointimal formation in arteries treated with gene delivery stents. This review summarizes prior work on stent-based gene delivery and discusses the main optimization strategies required to move the field of gene-eluting stents to clinical translation. PMID:26225356

  15. Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction

    PubMed Central

    2013-01-01

    Background Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. Methods Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. Results Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). Conclusions Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy. PMID:23410217

  16. Carotid artery stenting: current and emerging options

    PubMed Central

    Morr, Simon; Lin, Ning; Siddiqui, Adnan H

    2014-01-01

    Carotid artery stenting technologies are rapidly evolving. Options for endovascular surgeons and interventionists who treat occlusive carotid disease continue to expand. We here present an update and overview of carotid stenting devices. Evidence supporting carotid stenting includes randomized controlled trials that compare endovascular stenting to open surgical endarterectomy. Carotid technologies addressed include the carotid stents themselves as well as adjunct neuroprotective devices. Aspects of stent technology include bare-metal versus covered stents, stent tapering, and free-cell area. Drug-eluting and cutting balloon indications are described. Embolization protection options and new direct carotid access strategies are reviewed. Adjunct technologies, such as intravascular ultrasound imaging and risk stratification algorithms, are discussed. Bare-metal and covered stents provide unique advantages and disadvantages. Stent tapering may allow for a more fitted contour to the caliber decrement between the common carotid and internal carotid arteries but also introduces new technical challenges. Studies regarding free-cell area are conflicting with respect to benefits and associated risk; clinical relevance of associated adverse effects associated with either type is unclear. Embolization protection strategies include distal filter protection and flow reversal. Though flow reversal was initially met with some skepticism, it has gained wider acceptance and may provide the advantage of not crossing the carotid lesion before protection is established. New direct carotid access techniques address difficult anatomy and incorporate sophisticated flow-reversal embolization protection techniques. Carotid stenting is a new and exciting field with rapidly advancing technologies. Embolization protection, low-risk deployment, and lesion assessment and stratification are active areas of research. Ample room remains for further innovations and developments. PMID:25349483

  17. 77 FR 7589 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... current knowledge about the safety and effectiveness of the Wingspan Stent System with Gateway PTA Balloon... premarket and postmarket data. The Wingspan Stent System with Gateway PTA Balloon Catheter is a neurovascular stent, balloon catheter, and delivery system consisting of the following components: 1. Wingspan...

  18. Ureteric stents vs percutaneous nephrostomy for initial urinary drainage in children with obstructive anuria and acute renal failure due to ureteric calculi: a prospective, randomised study.

    PubMed

    ElSheemy, Mohammed S; Shouman, Ahmed M; Shoukry, Ahmed I; ElShenoufy, Ahmed; Aboulela, Waseem; Daw, Kareem; Hussein, Ahmed A; Morsi, Hany A; Badawy, Hesham

    2015-03-01

    To compare percutaneous nephrostomy (PCN) tube vs JJ ureteric stenting as the initial urinary drainage method in children with obstructive calcular anuria (OCA) and post-renal acute renal failure (ARF) due to bilateral ureteric calculi, to identify the selection criteria for the initial urinary drainage method that will improve urinary drainage, decrease complications and facilitate the subsequent definitive clearance of stones, as this comparison is lacking in the literature. A series of 90 children aged ≤12 years presenting with OCA and ARF due to bilateral ureteric calculi were included from March 2011 to September 2013 at Cairo University Pediatric Hospital in this randomised comparative study. Patients with grade 0-1 hydronephrosis, fever or pyonephrosis were excluded. No patient had any contraindication for either method of drainage. Stable patients (or patients stabilised by dialysis) were randomised (non-blinded, block randomisation, sealed envelope method) into PCN-tube or bilateral JJ-stent groups (45 patients for each group). Initial urinary drainage was performed under general anaesthesia and fluoroscopic guidance. We used 4.8-6 F JJ stents or 6-8 F PCN tubes. The primary outcomes were the safety and efficacy of both groups for the recovery of renal functions. Both groups were compared for operative and imaging times, complications, and the period required for a return to normal serum creatinine levels. The secondary outcomes included the number of subsequent interventions needed for clearance of stones. Additional analysis was done for factors affecting outcome within each group. All presented patients completed the study with intention-to-treat analysis. There was no significant difference between the PCN-tube and JJ-stent groups for the operative and imaging times, period for return to a normal creatinine level and failure of insertion. There were significantly more complications in the PCN-tube group. The stone size (>2 cm) was the only factor affecting the rates of mucosal complications, operative time and failure of insertion in the JJ-stent group. The degree of hydronephrosis significantly affected the operative time for PCN-tube insertion. Grade 2 hydronephrosis was associated with all cases of insertion failure in the PCN-tube group. The total number of subsequent interventions needed to clear stones was significantly higher in the PCN-tube group, especially in patients with bilateral stones destined for chemolytic dissolution (alkalinisation) or extracorporeal shockwave lithotripsy (ESWL). We recommend the use of JJ stents for initial urinary drainage for stones that will be subsequently treated with chemolytic dissolution or ESWL, as this will lower the total number of subsequent interventions needed to clear the stones. This is also true for stones destined for ureteroscopy (URS), as JJ-stent insertion will facilitate subsequent URS due to previous ureteric stenting. Mild hydronephrosis will prolong the operative time for PCN-tube insertion and may increase the incidence of insertion failure. We recommend the use of PCN tube if the stone size is >2 cm, as there was a greater risk of possible iatrogenic ureteric injury during stenting with these larger ureteric stones in addition to prolongation of operative time with an increased incidence of failure. © 2014 The Authors. BJU International © 2014 BJU International.

  19. Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms.

    PubMed

    Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua

    2018-01-01

    To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.

  20. A prospective, multicenter study of a double stent system for palliative treatment of malignant extrahepatic biliary obstructions.

    PubMed

    Kim, Jong Woo; Gwon, Dong Il; Han, Young-Min; Won, Je Hwan; Hong, Hyun Pyo; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo

    2015-10-01

    A double stent system (covered stent in uncovered stent) was designed to provide long-term patency without tumor ingrowth or stent-related complications, such as stent migration, cholecystitis, or pancreatitis. To investigate the safety and efficacy of double stents in patients with malignant extrahepatic biliary obstructions. This prospective, nonrandomized, multicenter study enrolled 160 consecutive patients (102 men; mean age, 64 years; range, 33-91 years) with malignant extrahepatic biliary obstructions treated with a double stent system from January 2010 to March 2012. The technical success rate of the double stent placement was 100%. No stent migration was observed. Procedure-related minor (self-limiting hemobilia [n = 6] and cholangitis [n = 2]) and major (pancreatitis [n = 16], cholecystitis [n = 3], and hepatic abscess [n = 2]) complications occurred in a total of 29 patients. The mean serum bilirubin level, which was 8.9 ± 5.6 mg/dL before drainage, decreased to 2.2 ± 4.6 mg/dL 1 month after stent placement (P < 0.001). Successful internal drainage was achieved in 148 patients (92.5%). During the mean follow-up period of 205 days, acute cholecystitis (n = 3) and hepatic abscess (n = 2) occurred in five patients. The median patient survival and stent patency time were 135 days (95% confidence interval [CI], 96-160 days) and 114 days (95% CI, 83-131 days), respectively. Of 153 patients, 22 (14.4%) presented with stent dysfunction due to sludge incrustation (n = 17), tumor overgrowth (n = 4), or blood clot (n = 1), and required repeat intervention. Tumor ingrowth was not observed in any of these patients. Percutaneous treatment of malignant extrahepatic biliary obstruction using a double stent safely and effectively achieves internal biliary drainage. © The Foundation Acta Radiologica 2014.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Eun Sun, E-mail: seraph377@gmail.com; Han, Joon Koo, E-mail: hanjk@snu.ac.kr; Baek, Ji-Hyun, E-mail: 100paper@gmail.com

    PurposeWe aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents.Materials and MethodsThis study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34–68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based onmore » clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29–9.95 years). We assessed treatment success rate and patient and graft survival times.ResultsDuring the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00–9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42–4.25).ConclusionsPercutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.« less

  2. Endoscopic management of occluded metal biliary stents: Metal versus 10F plastic stents

    PubMed Central

    Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin

    2010-01-01

    AIM: To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. METHODS: We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. RESULTS: Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). CONCLUSION: Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS. PMID:21072899

  3. Endoscopic management of occluded metal biliary stents: metal versus 10F plastic stents.

    PubMed

    Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin

    2010-11-14

    To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS.

  4. 76 FR 47210 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    .......... Medtronic Vascular.... Valiant thoracic stent graft April 1, 2011. system. H100002 FDA-2011-M-0241... Scientific Corp ION paclitaxel-eluting coronary April 22, 2011. stent system (monorail and over- the-wire..., 2011. toric IOL. P040012 (S34) FDA-2011-M-0343. Abbott Vascular, Inc.. RX Acculink carotid stent system...

  5. 76 FR 31965 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    .... ENDURANT STENT GRAFT SYSTEM. FDA-2011-M-0040 P100010 Medtronic Cryocath, ARCTIC FRONT December 17, 2010. LP.... Vascular. LX VASCULAR STENT SYSTEMS. FDA-2011-M-0039 P070026 Depuy, Inc......... CERAMAX CERAMIC HIP.... EXPANDABLE RENAL STENT SYSTEM. FDA-2011-M-0056 P090013 Medtronic, Inc..... REVO MRI SURESCAN IPG February 8...

  6. 77 FR 15779 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-16

    ... 26, 2011. iliac balloon- expandable stent system. P100042, FDA-2011-M-0792 Gen-Probe APTIMA HPV assay..., 2011. XIENCE PRIME LL EVEROLIMUS-eluting coronary stent system. P100041, FDA-2011-M-0837 Edwards.... EVEROLIMUS-eluting platinum chromium coronary stent system. P100024, FDA-2011-M-0866 Dako Denmark A/S...

  7. Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Zhongmin, E-mail: wzm0722@hotmail.co; Chen Kemin, E-mail: ckm0722@hotmail.co; Gong Ju

    Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival timemore » between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.« less

  8. Bilateral complete ureteral duplication with calculi obstructing both limbs of left double ureter.

    PubMed

    Aiken, William D; Johnson, Peter B; Mayhew, Richard G

    2015-01-01

    A woman with bilateral complete ureteral duplication with stones simultaneously obstructing both limbs of the left double ureter is presented. A search of the English medical literature suggests that this is the first reported case. Based on the initial difficulty accessing the stones via ureteroscopy we make recommendations regarding how this rare problem should be approached if encountered. A 37-year old woman with left-sided flank pain was discovered on CT scan to have bilateral complete ureteral duplication and three stones obstructing both limbs of the left double ureter. Ureteroscopy was initially unsuccessful due to the very small calibre and unyielding nature of the ureters and both ureteral limbs were stented. Repeat ureteroscopy was easily achieved after pre-stenting and the impacted stones were completely cleared with intracorporeal laser lithotripsy. The smaller calibre of both double ureters and their presence in a common adventitial sheath distally, made initial attempts at ureteroscopy difficult. Stenting both limbs increased ureteral compliance, passively dilated both ureters and allowed for improved manoeuvrability and retrograde passage of the ureteroscope. Based on the experience with this first reported case it is recommended that pre-stenting should be routinely performed prior to any attempt at ureteroscopy in cases of stones complicating completely duplicated ureters. We report the first recorded case of bilateral complete ureteral duplication with stones simultaneously obstructing both limbs of the double ureter and recommend that routine pre-stenting be done prior to ureteroscopy to allow easy uncomplicated retrograde passage of the ureteroscope. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Disappearing and reappearing differences in drug-eluting stent use by race.

    PubMed

    Federspiel, Jerome J; Stearns, Sally C; Reiter, Kristin L; Geissler, Kimberley H; Triplette, Matthew A; D'Arcy, Laura P; Sheridan, Brett C; Rossi, Joseph S

    2013-04-01

    Drug-eluting coronary stents (DES) rapidly dominated the marketplace in the United States after approval in 2003, but utilization rates were initially lower among African American patients. We assess whether racial differences persisted as DES diffused into practice. Medicare claims data were used to identify coronary stenting procedures among elderly patients with acute coronary syndromes (ACS). Regression models of the choice of DES versus bare mental stent controlled for demographics, ACS type, co-morbidities and hospital characteristics. Diffusion was assessed in the short run (2003-2004) and long run (2007), with the effect of race calculated to allow for time-varying effects. The sample included 381,887 Medicare beneficiaries treated with stent insertion; approximately 5% were African American. Initially (May 2003-February 2004), African American race was associated with lower DES use compared to other races (44.3% versus 46.5%, P < 0.01). Once DES usage was high in all patients (March-December 2004), differences were not significant (79.8% versus 80.3%, P = 0.45). Subsequent concerns regarding DES safety caused reductions in DES use, with African Americans having lower use than other racial groups in 2007 (63.1% versus 65.2%, P < 0.01). Racial disparities in DES use initially disappeared during a period of rapid diffusion and high usage rates; the reappearance of disparities in use by 2007 may reflect DES use tailored to unmeasured aspects of case mix and socio-economic status. Further work is needed to understand whether underlying differences in race reflect decisions regarding treatment appropriateness. © 2011 Blackwell Publishing Ltd.

  10. Analysis of emboli during carotid stenting with distal protection device.

    PubMed

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p < 0.001). During stenting and angioplasty with the protection device, 7,395 emboli with 42% solids were detected (p < 0.001). Finally injection of contrast after the procedure, with the protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  11. Comparison of partially covered nitinol stents with partially covered stainless stents as a historical control in a multicenter study of distal malignant biliary obstruction: the WATCH study.

    PubMed

    Isayama, Hiroyuki; Mukai, Tsuyoshi; Itoi, Takao; Maetani, Iruru; Nakai, Yousuke; Kawakami, Hiroshi; Yasuda, Ichiro; Maguchi, Hiroyuki; Ryozawa, Shomei; Hanada, Keiji; Hasebe, Osamu; Ito, Kei; Kawamoto, Hirofumi; Mochizuki, Hitoshi; Igarashi, Yoshinori; Irisawa, Atsushi; Sasaki, Tamito; Togawa, Osamu; Hara, Taro; Kamada, Hideki; Toda, Nobuo; Kogure, Hirofumi

    2012-07-01

    Covered self-expandable metal stents (CSEMSs) were developed to prevent tumor ingrowth, but stent migration is one of the problems with CSEMSs. To evaluate a new, commercially available CSEMS with flared ends and low axial force compared with a commercially available CSEMS without the anti-migration system and high axial force. Multicenter, prospective study with a historical cohort. Twenty Japanese referral centers. This study involved patients with unresectable distal malignant biliary obstruction. Placement of a new, commercially available, partially covered SEMS. Recurrent biliary obstruction rate, time to recurrent biliary obstruction, stent-related complications, survival. Between April 2009 and March 2010, 141 patients underwent partially covered nitinol stent placement, and between May 2001 and January 2007, 138 patients underwent placement of partially covered stainless stents as a historical control. The silicone cover of the partially covered nitinol stents prevented tumor ingrowth. There were no significant differences in survival (229 vs 219 days; P = .250) or the rate of recurrent biliary obstruction (33% vs 38%; P = .385) between partially covered nitinol stents and partially covered stainless stents. Stent migration was less frequent (8% vs 17%; P = .019), and time to recurrent biliary obstruction was significantly longer (373 vs 285 days; P = .007) with partially covered nitinol stents. Stent removal was successful in 26 of 27 patients (96%). Nonrandomized, controlled trial. Partially covered nitinol stents with an anti-migration system and less axial force demonstrated longer time to recurrent biliary obstruction with no tumor ingrowth and less stent migration. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Efficacy of a Multiplex Paclitaxel Emission Stent Using a Pluronic® Mixture Membrane versus a Covered Metal Stent in Malignant Biliary Obstruction: A Prospective Randomized Comparative Study.

    PubMed

    Jang, Sung Ill; Lee, Se Joon; Jeong, Seok; Lee, Don Haeng; Kim, Myung-Hwan; Yoon, Hong Jin; Lee, Dong Ki

    2017-07-15

    A drug-eluting stent for unresectable malignant biliary obstruction was developed to increase stent patency by preventing tumor ingrowth. The safety and efficacy of a new generation of metallic stents covered with a paclitaxel-incorporated membrane using a Pluronic ® mixture (MSCPM-II) were compared prospectively with those of covered metal stents (CMSs) in patients with malignant biliary obstructions. This study was initially designed as a prospective randomized trial but was closed early because of a high incidence of early occlusion. Therefore, the data were analyzed using the intent-to-treat method. A total of 72 patients with unresectable distal malignant biliary obstructions were prospectively enrolled. The two groups did not differ significantly in basic characteristics and mean follow-up period (MSCPM-II 194 days vs CMS 277 days, p=0.063). Stent occlusion occurred in 14 patients (35%) who received MSCPM-II and in seven patients (21.9%) who received CMSs. Stent patency and survival time did not significantly differ between the two groups (p=0.355 and p=0.570). The complications were mild and resolved by conservative management in both groups. There were no significant differences in stent patency or patient survival in MSCPM-II and CMS patients with malignant biliary obstructions.

  13. The applicability of using straight ureteral stents for the treatment of ureteral stones in presumably non-compliant patients.

    PubMed

    Mydlo, J H; Streater, S

    2001-01-01

    There have been many reports describing the complications of retained ureteral stents following stone treatment. We wanted to evaluate the practicality of definitive treatment of poorly compliant patients who present with ureteral stones using a straight stent connected to a urethral catheter alone and compared these to patients treated with double-J stents alone. We treated 23 patients (12 in group I and 11 patients in group II) who had a ureteral stone of 6 mm or less, with an indwelling straight stent and a double-J stent, respectively, while on oral antibiotics. We followed these patients 1 week later with an abdominal X-ray prior to removing the stent. Eleven patients in group I and 9 patients in group II passed their stones spontaneously. Three patients required surgical intervention with a ureterscope and laser lithotripsy. There were no cases of infection or pyelonephritis. Although each of the straight-stent-treated patients returned to our clinic for follow-up, only 5 of the 11 double-J stent patients returned for follow-up. The remaining 6 patients had to be contacted to remind them that they still had an internal stent. Although technologic advances now allow many urologists to definitively treat ureteral stones, some urologists may lack the proper equipment and/or assistance to treat the stone at the time of presentation, or may deal with non-compliant patients. Therefore, in these certain circumstances, treatment of small ureteral stones in non-compliant patients using a straight stent connected to a leg bag, as either definitive or initial treatment, may be of practical use and avoid the risk of retained double-J ureteral stents. Copyright 2001 S. Karger AG, Basel

  14. Jailed double-microcatheter technique following horizontal stenting for coil embolization of intracranial wide-necked bifurcation aneurysms: A technical report of two cases.

    PubMed

    Kitahara, Takahiro; Hatano, Taketo; Hayase, Makoto; Hattori, Etsuko; Miyakoshi, Akinori; Nakamura, Takehiko

    2017-04-01

    The horizontal stenting technique facilitates endovascular treatment of wide-necked bifurcation intracranial aneurysms. Previous literature shows, however, that subsequent coil embolization at initial treatment results in incomplete obliteration in many cases. The authors present two consecutive cases of wide-necked large bifurcation aneurysms to describe an additional coil embolization technique following horizontal stenting. The patients were a 53-year-old female with an unruptured internal carotid artery terminus aneurysm and a 57-year-old female with a recurrent basilar artery tip aneurysm. Both patients underwent endovascular treatment with horizontal stenting followed by coil embolization with jailed double-microcatheters. Immediate complete obliteration was achieved with no complications, and no recanalization was observed at the one-year follow-up in both cases. Coil embolization with jailed double-microcatheter technique following horizontal stenting is a safe and effective strategy for wide-necked bifurcation aneurysms.

  15. A new thermal shape memory Ti-Ni alloy stent covered with silicone.

    PubMed

    Nakamura, T; Shimizu, Y; Ito, Y; Matsui, T; Okumura, N; Takimoto, Y; Ariyasu, T; Kiyotani, T

    1992-01-01

    An attempt was made to develop an airway stent for nonsurgical transluminal implantation using a bronchofiberscope. The stent is composed of a single wire with a diameter of 0.5 mm. The wire is made of thermal shape memory titanium nickel alloy, with a transition temperature of 25-30 degrees C. To avoid direct contact between the metal and the tissue, the wire is covered with a 300 microns thick coating of silicone. The stent is horseshoe shaped in cross-section. It is 15 mm in outer transverse diameter and 40 mm long. Ten stents were implanted in 10 dogs whose tracheal cartilages had been previously broken. The stents were first cooled in ice water to reduce their diameter and then inserted into the target site. The wire was warmed to body temperature and recovered its initial shape within 10 sec. The dogs were killed for examination between 1 week and 6 months after implantation. All the stents were located at the implantation sites and were patent. Tissue reactions, such as ulceration and granulation formation, were less severe than in those with previously implanted non-silicone covered stents. Microscopic observation showed that the wires became gradually covered with epithelium within 2 months. This transluminal technique for preserving airway patency shows promise for clinical application.

  16. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    PubMed

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P < 0.05) at 1.5 and 3 T. Maximum visible stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  17. Clinical Results and Mechanical Properties of the Carotid CGUARD Double-Layered Embolic Prevention Stent.

    PubMed

    Wissgott, Christian; Schmidt, Wolfram; Brandt-Wunderlich, Christoph; Behrens, Peter; Andresen, Reimer

    2017-02-01

    To report early clinical outcomes with a novel double-layer stent for the internal carotid artery (ICA) and the in vitro investigation of the stent's mechanical properties. A prospective single-center study enrolled 30 consecutive patients (mean age 73.1±6.3 years; 21 men) with symptomatic (n=25) or high-grade (n=5) ICA stenosis treated with the new double-layer carotid CGUARD Embolic Prevention System (EPS) stent, which has an inner open-cell nitinol design with an outer closed-cell polyethylene terephthalate layer. The average stenosis of the treated arteries was 84.1%±7.9% with a mean lesion length of 16.6±2.1 mm. In the laboratory, 8×40-mm stents where tested in vitro with respect to their radial force during expansion, the bending stiffness of the stent system and the expanded stent, as well as the collapse pressure in a thin and flexible sheath. The wall adaptation was assessed using fluoroscopy after stent release in step and curved vessel models. The stent was successfully implanted in all patients. No peri- or postprocedural complications occurred; no minor or major stroke was observed in the 6-month follow-up. The bending stiffness of the expanded stent was 63.1 N·mm 2 and (not unexpectedly) was clearly lower than that of the stent system (601.5 N·mm 2 ). The normalized radial force during expansion of the stent to 7.0 mm, consistent with in vivo sizing, was relatively high (0.056 N/mm), which correlates well with the collapse pressure of 0.17 bars. Vessel wall adaptation was harmonic and caused no straightening of the vessel after clinical application. Because of its structure, the novel CGUARD EPS stent is characterized by a high flexibility combined with a high radial force and very good plaque coverage. These first clinical results demonstrate a very safe implantation behavior without any stroke up to 6 months after the procedure.

  18. Role of Animal Models in Coronary Stenting.

    PubMed

    Iqbal, Javaid; Chamberlain, Janet; Francis, Sheila E; Gunn, Julian

    2016-02-01

    Coronary angioplasty initially employed balloon dilatation only. This technique revolutionized the treatment of coronary artery disease, although outcomes were compromised by acute vessel closure, late constrictive remodeling, and restenosis due to neointimal proliferation. These processes were studied in animal models, which contributed to understanding the biology of endovascular arterial injury. Coronary stents overcome acute recoil, with improvements in the design and metallurgy since then, leading to the development of drug-eluting stents and bioresorbable scaffolds. These devices now undergo computer modeling and benchtop and animal testing before evaluation in clinical trials. Animal models, including rabbit, sheep, dog and pig are available, all with individual benefits and limitations. In smaller mammals, such as mouse and rabbit, the target for stenting is generally the aorta; whereas in larger animals, such as the pig, it is generally the coronary artery. The pig coronary stenting model is a gold-standard for evaluating safety; but insights into biomechanical properties, the biology of stenting, and efficacy in controlling neointimal proliferation can also be gained. Intra-coronary imaging modalities such as intravascular ultrasound and optical coherence tomography allow precise serial evaluation in vivo, and recent developments in genetically modified animal models of atherosclerosis provide realistic test beds for future stents and scaffolds.

  19. Proximal protection with hybrid stent, a safer combination for carotid artery stenting against carotid endarterectomy?

    PubMed

    Gürkaş, E; Ak, F; Orhan, G; Bozkurt, E; Ulusoy, E K

    2015-12-01

    Carotid revascularization is an established theurapeutic modality in preventing stroke and death among patients with severe carotid stenosis. Although carotid endarterectomy remains as the primary option, carotid stenting is accepted as an alternative for patients with high risk for carotid endarterectomy. Recently published reports have better results with proximal protection devices when compared with distal protection devices. These studies have revealed less microembolic signals and less periprocedural new ischemic lesions on diffusion weighted magnetic resonance imaging. Stent choice may be also important for these procedures as open cell stent design has advantage of better flexibility whereas closed cell systems have an advantage of better scaffolding. Hybrid stents which are composed of open cells in the proximal and distal part and closed cells in the middle may carry both advantages. The aim of this study is to demonstrate whether combination of proximal protection devices with hybrid stents can be a safe alternative for carotid stenting in terms of periprocedural and 30-day outcomes. Here we retrospectively evaluated 68 symptomatic carotid stenosis patients undergoing carotid stenting with hybrid stent (Cristallo Ideale®, Invatec s.r.l., Medtronic, Italy) and proximal protection device (MO.MA®, Invatec s.r.l., Medtronic, Italy). Our results showed only 1 minor stroke in the periprocedural period and during the first 30-day after stenting, with no death or myocardial infarction. Although our case number is not large, we propose that carotid stenting may be safer with utilization of proximal protection system and hybrid type carotid stents.

  20. Microbiology and Biofilm Trends of Silicone Lacrimal Implants: Comparing Infected Versus Routinely Removed Stents.

    PubMed

    Samimi, David B; Ediriwickrema, Lilangi S; Bielory, Brett P; Miller, Darlene; Lee, Wendy; Johnson, Thomas E

    To investigate the pathogens and biofilms responsible for clinically significant infection of silicone stents implanted within the lacrimal system. Retrospective review of culture results and patient demographics for all silicone lacrimal stents removed early for clinically significant infection and sent to the Bascom Palmer Microbiology Laboratory through the end of year 2010. As a control, routinely removed, clinically noninfected stents from the same institution were prospectively sent for culture over a 6-month period. Four clinically infected and 6 clinically noninfected stents showing mucus within the lumen at removal were sent for scanning electron microscopy. Images were randomized and graded by a microbiologist for the presence of organisms, matrix deposits, organisms within matrix, and overall impression of significant biofilm formation. Nineteen stents were included in the study; 100% of clinically infected (n = 10) and noninfected (n = 9) stents were culture positive. Culture positivity for nontuberculous mycobacterium was found in 90% of infected stents and none of the noninfected stents (p < 0.001). Of infected stents, 50% grew Gram-positive organisms compared with 89% of noninfected stents (p = 0.07). Fifty percent of infected versus 67% of noninfected stents were culture positive for Gram-negative organisms (p = 0.46). Electron microscopy of stents revealed organisms consistent with culture results (size, shape) in planktonic and biofilm form. Masked observer image grading revealed a statistically significant higher amount of organism and biofilm on infected versus noninfected specimen. Nontuberculous mycobacteria comprise the primary pathogens responsible for clinically significant infection of silicone stents in the lacrimal system in South Florida. Robust biofilm production by this organism likely plays a role in pathogenesis. Further research into biofilm-related lacrimal implant infection may aid in the development of useful prevention and treatment strategies.

  1. Evaluation of a bifurcation drug-eluting stent system versus provisional T-stenting in a perfused synthetic coronary artery model.

    PubMed

    Rizik, David G; Klag, Joseph M; Tenaglia, Alan; Hatten, Thomas R; Barnhart, Marianne; Warnack, Boris

    2009-12-01

    Provisional T-stenting is a widely used strategy for the treatment of coronary artery bifurcation lesions. However, the use of conventional stents in this setting is limited by multiple factors; this includes technical considerations such as wire wrap when accessing the involved vessel, and stent overlap at or near the carina of the lesion. In addition, current slotted tube stent technology tends to be associated with gaps in the coverage of the side branch ostium, which may result in restenosis in that segment of the lesion. The Pathfinder device, now more commonly referred to as the Xience Side Branch Access System (Xience SBA) is a drug-eluting stent (DES) designed specifically to assist in the treatment of bifurcation lesions by allowing wire access into the side branch, irrespective of the treatment strategy to be employed. The Xience SBA drug-eluting stent was compared with the standard Vision coronary stent system using a provisional T-stenting strategy in a perfused synthetic model of the coronary vasculature with side branch angulations of 30 degrees , 50 degrees , 70 degrees , and 90 degrees . Stent delivery was performed under fluoroscopic guidance. Following the procedure, high-resolution 2D Faxitron imaging was used to evaluate deployment accuracy of the side branch stent relative to the main branch stent. Deployment of the Xience SBA was accomplished in the same total time as the standard stents in a provisional T-stenting approach (14.9 vs. 14.6 minutes). However, the time required to achieve stent deployment in the main branch was less with the Xience SBA (4.0 vs. 6.6 minutes), and as a result, total contrast usage (49.4 vs. 69.4 cm(3)) and fluoroscopy time (5.1 vs. 6.2 minutes) was lower. Additionally, the Xience SBA had a lower incidence of wire wrap (22% vs. 89%) and less distal protrusion of the side branch stent into the main branch (0.54 vs. 1.21 mm). Significant gaps in ostial side branch coverage were not seen in either group. The Xience Side Branch Access DES is a viable device for consistently accessing coronary bifurcation lesions; it allows for easy wire access into the side branch. This may assist the operator in overcoming those well-recognized limitations associated with use of standard one- or two-stent strategies. In this perfused synthetic coronary model, Xience SBA deployment required less contrast usage and shorter fluoroscopy times. Further testing of this device is warranted.

  2. Preliminary study for a newly designed silicone stent and delivery system for canine obstructive tracheal disease.

    PubMed

    Kim, Dae-Hyun; Choi, Chi-Bong; Chung, Wook-Hun; Lee, Sung-Ho; Lee, A-Jin; Jeong, Jae-Seung; Kim, Ho-Joong; Kim, Hwi-Yool

    2012-10-01

    The goal of this study was to prove the possibility of using silicone stents broadly used for human medicine in canine obstructive tracheal disease. A silicone stent anatomically designed for canine trachea was tested on 5 beagle dogs for 8 weeks. The stent was carefully inserted using a newly developed delivery device under fluoroscopic guidance. There were no technical difficulties in placing the stent during the procedure. Previously reported complications of airway stenting such as stent migration or granulation tissue formation did not occur in any of the cases. In addition, removal of the stent was as simple as inserting it, and complications were absent. The stent introduced in this study could possibly be applied to various canine obstructive tracheal diseases.

  3. A novel photodynamic therapy-based drug delivery system layered on a stent for treating cholangiocarcinoma.

    PubMed

    Liang, Po-Chin; Huang, Kai-Wen; Tung, Chien-Chih; Chang, Ming-Chu; Chang, Fuh-Yu; Wong, Jau-Min; Chang, Yu-Ting

    2017-11-22

    This study aimed to investigate the drug delivery efficacy and bio-effectiveness of a novel photodynamic therapy (PDT)-matrix drug delivery system for cholangiocarcinoma (CCA). Metallic stents were coated with polyurethane (PU) as the first layer. A 2-hydroxyethyl methacrylate (2-HEMA)/ethylene glycol dimethacrylate (EGDMA)/benzoyl peroxide (BPO) layer and a poly(ethylene-co-vinyl acetate) (PEVA)/poly(n-butyl methacrylate) (PBMA)/polyvinylpyrrolidone K30 (K30) layer containing various concentrations of Photofrin were then incorporated onto the stent as the second and third layers. After incubating the layered membranes with cultured CCA cell line, the release of Photofrin, cell viability, the intracellular uptake of Photofrin, reactive oxygen species (ROS) generation, and apoptosis were determined. Using a single-layer diffusion model, the maximum release of Photofrin from the 5 to 10% K30 formulas was 80 and 100%, respectively, after 24 h. When using the multiple-layer diffusion model, the released Photofrin showed an initial burst of the loading dose from the PEVA/PBMA/K30 layer. In the immobilized model, less than 5% of the Photofrin from the 2-HEMA/EGDMA/BPO layer was released over the 24-h period. Cell viability decreased linearly with increasing Photofrin concentrations, and ROS generation and apoptosis were shown to increase significantly with increasing Photofrin concentrations, until the concentration of Photofrin reached a saturation point of 1.5 μg/ml. This new, multiple-layered, PDT-based stent with dual-release mechanisms is a promising treatment for CCA and cancer-related ductal stenosis.

  4. Stenting of long coronary artery lesions: initial angiographic results and 6-month clinical outcome of the micro stent II-XL.

    PubMed

    Schalij, M J; Udayachalerm, W; Oemrawsingh, P; Jukema, J W; Reiber, J H; Bruschke, A V

    1999-09-01

    To evaluate the results of long Micro Stent II (MS-XL) implantations, 119 MS-XLs were implanted in 102 patients (age, 62.83 years). Nineteen stents (16%) were implanted in saphenous vein grafts; 100 stents (84%) were implanted in native coronary arteries. Twenty-five patients (25%) were treated because of acute myocardial infarction (AMI); 30 patients (29%) because of unstable angina or angina class IV, and 47 patients (46%) because of stable angina. Eighty-six de novo lesions (84%) and 16 restenotic lesions (16%) were treated. Indications for stent implantation include elective, 61 patients (60%); suboptimal balloon angioplasty result, 22 patients (21%); and bailout after balloon angioplasty, 19 patients (19%). Because of residual thrombus after stenting, 27 patients (26%) received abciximab. All patients received ticlopidin for 28 days and acetylsalicylic acid. One hundred and seventeen MS-XLs (98%) were implanted successfully. Additional (shorter) MS-II were implanted in 40 patients (39%). The stented segment length was 45 +/- 20 mm. The minimum lumen diameter increased from 0.5 +/- 0.5 mm before to 2.7 +/- 0.5 mm after stent implantation. The acute gain was 2.2 +/- 0.4 mm. Early clinical events (<4 weeks) include death, 3 (3%); subacute stent thrombosis, 1 (1%); non-Q-wave infarction, 2 (2%); CABG, 1 (1%); vascular complications, 2 (2%). Late clinical events (<6 months) include acute myocardial infarction, 5 (5%); reintervention, 6 (6%); CABG, 1 (1%). The procedural success rate was 88%, and the event free survival at 6 months was 76%. Stenting of long lesions with the MS-XL was successful and associated with an acceptable complication rate. Cathet. Cardiovasc. Intervent. 48:105-112, 1999. Copyright 1999 Wiley-Liss, Inc.

  5. Stenting versus non-stenting following uncomplicated ureteroscopic lithotripsy: Comparsion and evaluation of symptoms.

    PubMed

    Savić, Slaviša; Vukotić, Vinka; Lazić, Miodrag; Savić, Nataša

    2016-09-01

    Currently, ureterorenoscopic (URS) stone fragmentation and removal is the treatment of choice for managing ureteral stones, especially mid and distal ones and is advocated as initial management of ureteric stones. The aim of this work was to evaluate the symptoms, necessity, potential benefits and adverse effects of ureteral stent placement after uncomplicated ureteroscopic lithotripsy. This retrospective-prospective study evaluated a total of 125 patients who had underwent ureteroscopic lithotripsy (URSL). The patients were divided into two groups: stented (59 patients) and unstented (controls, 66 patients). The outcomes measured and compared between the two groups included: stone free rate, postoperative patient pain validated by scale, lower urinary tract symptoms (LUTS), the need for unplanned hospital care, stent related complications, and functional recovery in the form return to normal physical activities. A successful outcome, defined as being stonefree after 12 weeks, was achieved in all 125 (100%) patients. The stone-free rate showed no significant differences between the two groups. LUTS was frequent complaint in the stented group, with statistically significant difference in the domain of frequency/urgency (p = 0.0314). There was a statistically significant difference between the groups in the mean operative time and mean hospitalization time, mean pain visual analog scale (VAS) score and in the use of nonnarcotic analgesic. On the day of the surgery and until postoperative day 3 (POD 3) and postoperative day 5 (POD 5), the pain score was much higher among stented patients than among the controls (p = 0.0001) and non-narcotic analgesic use (p = 0.001) was frequently required in the stented group. Routine placement of ureteral stent after URSL is not mandatory and may be associated with stent side effects. Uncomplicated URSL is safe without stent placement after the treatment.

  6. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults.

    PubMed

    Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam

    2017-09-01

    Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P < 0.001). Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.

  7. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    PubMed

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  8. A novel endobronchial approach to massive hemoptysis complicating silicone Y-stent placement for tracheobronchomalacia: A case report.

    PubMed

    Ryu, Changwan; Boffa, Daniel; Bramley, Kyle; Pisani, Margaret; Puchalski, Jonathan

    2018-02-01

    Airway stabilization for severe, symptomatic tracheobronchomalacia (TBM) may be accomplished by silicone Y-stent placement. Common complications of the Y-stent include mucus plugging and granulation tissue formation. We describe a rare case of massive hemoptysis originating from a silicone Y-stent placed for TBM. An emergent bronchoscopy showed an actively bleeding, pulsatile vessel at the distal end of the left bronchial limb of the Y-stent. It was felt that the bleeding was caused by, or at least impacted by, the distal left bronchial limb of the Y-stent eroding into the airway wall. We hypothesized that placement of oxidized regenerated cellulose (ORC) would provide initial hemostasis, and the subsequent placement of a biocompatible surgical sealant would lead to definitive resolution. ORC provided sufficient hemostasis and the subsequent synthetic polymer reinforced the tissue for complete cessation of the bleed. The combined use of ORC and a biocompatible surgical sealant provided long-term management for life-threatening hemoptysis, and potentially morbid procedures such as embolization or surgery were avoided by advanced endobronchial therapy.

  9. A novel endobronchial approach to massive hemoptysis complicating silicone Y-stent placement for tracheobronchomalacia

    PubMed Central

    Ryu, Changwan; Boffa, Daniel; Bramley, Kyle; Pisani, Margaret; Puchalski, Jonathan

    2018-01-01

    Abstract Rationale: Airway stabilization for severe, symptomatic tracheobronchomalacia (TBM) may be accomplished by silicone Y-stent placement. Common complications of the Y-stent include mucus plugging and granulation tissue formation. Patient concerns: We describe a rare case of massive hemoptysis originating from a silicone Y-stent placed for TBM. Diagnoses: An emergent bronchoscopy showed an actively bleeding, pulsatile vessel at the distal end of the left bronchial limb of the Y-stent. It was felt that the bleeding was caused by, or at least impacted by, the distal left bronchial limb of the Y-stent eroding into the airway wall. Interventions: We hypothesized that placement of oxidized regenerated cellulose (ORC) would provide initial hemostasis, and the subsequent placement of a biocompatible surgical sealant would lead to definitive resolution. Outcomes: ORC provided sufficient hemostasis and the subsequent synthetic polymer reinforced the tissue for complete cessation of the bleed. Lessons: The combined use of ORC and a biocompatible surgical sealant provided long-term management for life-threatening hemoptysis, and potentially morbid procedures such as embolization or surgery were avoided by advanced endobronchial therapy. PMID:29465600

  10. Temporary placement of retrievable fully covered metallic stents versus percutaneous balloon dilation in the treatment of benign biliary strictures.

    PubMed

    Kim, Jin Hyoung; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Lee, Sung Koo; Yoon, Hyun-Ki; Shin, Ji Hoon; Song, Ho-Young

    2011-06-01

    To compare retrospectively percutaneous transhepatic primary placement of a retrievable self-expanding metallic stent with percutaneous balloon dilation for the treatment of benign biliary strictures. From 2005-2009, 66 patients with benign biliary strictures in whom an endoscopic approach failed or in whom such an approach was inaccessible were evaluated. Of 66 patients, 31 underwent balloon dilation, and 35 underwent temporary metallic stent placement. The etiologies of the benign strictures were anastomotic stricture after surgery (n = 54), stricture secondary to intraoperative injury (n = 9), inflammatory stricture (n = 2), and stricture secondary to trauma (n = 1). The primary patency rates were significantly better in the stent group (87% at 3 years) than in the balloon group (44% at 3 years; P = .022). The indwelling period of percutaneous transhepatic biliary drainage (PTBD) catheters after the initial procedure was able to be significantly reduced in the stent group (median 2.5 months) compared with the balloon group (median 4.5 months; P = .001). Significant bleeding (associated with PTBD) occurred in one patient in the balloon group. In the stent group, stent migration occurred in two patients, and one patient underwent surgery for stent removal after failure of removal under fluoroscopic guidance. Percutaneous primary placement of a retrievable self-expanding metallic stent showed superior intermediate-term results compared with percutaneous balloon dilation for the treatment of benign biliary strictures. In addition, the indwelling period of PTBD catheters can be significantly reduced using temporary stent placement. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  11. Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.

    PubMed

    Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui

    2016-09-01

    Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept "bio-adaption" between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed.

  12. Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review

    PubMed Central

    Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui

    2016-01-01

    Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept “bio-adaption” between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed. PMID:27698548

  13. Palliation of Malignant Biliary and Duodenal Obstruction with Combined Metallic Stenting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akinci, Devrim, E-mail: akincid@hotmail.com; Akhan, Okan; Ozkan, Fuat

    2007-11-15

    Purpose. The purpose of this study is to evaluate the efficacy of palliation of malignant biliary and duodenal obstruction with combined metallic stenting under fluoroscopy guidance. Materials and Methods. A retrospective analysis of 9 patients (6 men and 3 women) who underwent biliary and duodenal stenting was performed. The mean age of patients was 61 years (range: 42-80 years). The causes of obstruction were pancreatic carcinoma in 7 patients, cholangiocellular carcinoma in one, and duodenal carcinoma in the other. Biliary and duodenal stents were placed simultaneously in 4 patients. In other 5 patients dudodenal stents were placed after biliary stentingmore » when the duodenal obstruction symptoms have developed. In two patients duodenal stents were advanced via transgastric approach. Results. Technical success rate was 100 %. After percutaneous biliary drainage and stenting bilirubin levels decreased to normal levels in 6 patients and in remaining 3 patients mean reduction of 71% in bilirubin levels was achieved. Tumoral ingrowth occurred in one patient and percutaneous biliary restenting was performed 90 days after the initial procedure. Of the 9 patients, 6 patients were able to tolerate solid diet, whereas 2 patients could tolerate liquid diet and one patient did not show any improvement. Mean survival periods were 111 and 73 days after biliary and duodenal stenting, respectively. Conclusion. Combined biliary and duodenal stent placement which can be performed under fluoroscopic guidance without assistance of endoscopy is feasible and an effective method of palliation of malignant biliary and duodenal obstructions. If transoral and endoscopic approaches fail, percutaneous gastrostomy route allows duodenal stenting.« less

  14. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    PubMed

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm 2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  15. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence ofmore » bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula.« less

  16. A clinical evaluation of the ProNOVA XR polymer-free sirolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions (EURONOVA XR I study)☆

    PubMed Central

    Legutko, Jacek; Zasada, Wojciech; Kałuża, Grzegorz L.; Heba, Grzegorz; Rzeszutko, Lukasz; Jakala, Jacek; Dragan, Jacek; Klecha, Artur; Giszterowicz, Dawid; Dobrowolski, Wojciech; Partyka, Łukasz; Jayaraman, Swaminathan; Dudek, Dariusz

    2013-01-01

    Aims Evaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform. Methods and results Safety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm. At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up. Conclusions In this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up. PMID:23992999

  17. Long-term outcomes and risk factors of biliary stent dysfunction after endoscopic double stenting for malignant biliary and duodenal obstructions.

    PubMed

    Matsumoto, Kazuyuki; Kato, Hironari; Tsutsumi, Koichiro; Mizukawa, Sho; Yabe, Syuntaro; Seki, Hiroyuki; Akimoto, Yutaka; Uchida, Daisuke; Tomoda, Takeshi; Yamamoto, Naoki; Horiguchi, Shigeru; Kuwaki, Kenji; Okada, Hiroyuki

    2017-07-01

    Few reports describe the endoscopic double-stenting procedure for malignant biliary and duodenal obstructions. We evaluated the clinical outcomes from double stenting, and analyzed the risk factors for biliary stent dysfunction following double stenting. Eighty-one patients who underwent endoscopic double stenting for malignant biliary and duodenal obstructions were retrospectively analyzed. We determined the stent dysfunction rate and the biliary stent dysfunction risk factors, and analyzed the endoscopic reintervention results. Overall survival time and survival time following double stenting were 365 (38-1673) days and 73 (20-954) days, respectively. After double stenting, the 3-month and 6-month duodenal stent dysfunction rates were 14% and 41%, respectively. Reintervention technical success rate was 100% (10/10), and mean gastric outlet obstruction scoring system scores improved from 0.7 to 2.4 points (P < 0.001). The 3-month and 6-month biliary stent dysfunction rates were 26% and 41%, respectively. The reintervention technical and clinical success rates were 95% (20/21) and 81% (17/21), respectively. Risk factors for biliary stent dysfunction following double stenting were events associated with duodenal stent dysfunction (odds ratio [OR], 11.1; 95% confidence interval [CI], 2.09-87.4; P = 0.0044) and the biliary stent end's location (OR, 6.93; 95% CI, 1.37-40.2; P = 0.0019). Some patients had stent dysfunction irrespective of the survival period after double stenting. Endoscopic reintervention was technically feasible and clinically effective even after double stenting. Duodenal stent dysfunction and biliary stent end's location were risk factors for biliary stent dysfunction. © 2017 Japan Gastroenterological Endoscopy Society.

  18. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    PubMed

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels <3.0 mm (n=209) and type B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, p<0.001; long lesions 0.13+/-0.26 mm versus 0.43+/-0.46 mm, p=0.070; small vessels 0.17+/-0.28 mm versus 0.37+/-0.39 mm, p<0.001; B2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, p<0.001. The everolimus-eluting stent remained superior in terms of in-stent late loss in a variety of higher risk populations for restenosis compared to the paclitaxel-eluting stent. These analyses were consistent with the in-stent late loss results of the overall SPIRIT II trial population.

  19. Automated stent defect detection and classification with a high numerical aperture optical system

    NASA Astrophysics Data System (ADS)

    Bermudez, Carlos; Laguarta, Ferran; Cadevall, Cristina; Matilla, Aitor; Ibañez, Sergi; Artigas, Roger

    2017-06-01

    Stent quality control is a highly critical process. Cardiovascular stents have to be inspected 100% so as no defective stent is implanted in a human body. However, this visual control is currently performed manually and every stent could need tenths of minutes to be inspected. In this paper, a novel optical inspection system is presented. By the combination of a high numerical aperture (NA) optical system, a rotational stage and a line-scan camera, unrolled sections of the outer and inner surfaces of the stent are obtained and image-processed at high speed. Defects appearing in those surfaces and also in the edges are extremely contrasted due to the shadowing effect of the high NA illumination and acquisition approach. Therefore by means of morphological operations and a sensitivity parameter, defects are detected. Based on a trained defect library, a binary classifier sorts each kind of defect through a set of scoring vectors, providing the quality operator with all the required information to finally take a decision. We expect this new approach to make defect detection completely objective and to dramatically reduce the time and cost of stent quality control stage.

  20. Causes of failure with Szabo technique - an analysis of nine cases.

    PubMed

    Jain, Rajendra Kumar; Padmanabhan, T N C; Chitnis, Nishad

    2013-01-01

    The objective of this case series is to identify and define causes of failure of Szabo technique in rapid-exchange monorail system for ostial lesions. From March 2009 to March 2011, 42 patients with an ostial lesion were treated percutaneously at our institution using Szabo technique in a monorail stent system. All patients received unfractionated heparin during intervention. Loading dose of clopidogrel, followed by clopidogrel and aspirin was administered. In 57% of patients, drug-eluting stents were used and in 42.8% patients bare metal stents. The stent was advanced over both wires, the target wire and the anchor wire. The anchor wire, which was passed through the proximal trailing strut of the stent helps to achieve precise stenting. The procedure was considered to be successful if stent was placed precisely covering the lesion and without stent loss or anchor wire prolapsing. Of the total 42 patients, the procedure was successful in 33, while failed in 9. Majority of failures were due to wire entanglement, which was fixed successfully in 3 cases by removing and reinserting the anchor wire. Out of other three failures, in one stent dislodgment occurred, stent could not cross the lesion in one and in another anchor wire got looped and prolapsed into target vessel. This case series shows that the Szabo technique, in spite of some difficulties like wire entanglement, stent dislodgement and resistance during stent advancement, is a simple and feasible method for treating variety of ostial lesions precisely compared to conventional angioplasty. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  1. Causes of failure with Szabo technique – An analysis of nine cases

    PubMed Central

    Jain, Rajendra Kumar; Padmanabhan, T.N.C.; Chitnis, Nishad

    2013-01-01

    Objective The objective of this case series is to identify and define causes of failure of Szabo technique in rapid-exchange monorail system for ostial lesions. Methods and results From March 2009 to March 2011, 42 patients with an ostial lesion were treated percutaneously at our institution using Szabo technique in a monorail stent system. All patients received unfractionated heparin during intervention. Loading dose of clopidogrel, followed by clopidogrel and aspirin was administered. In 57% of patients, drug-eluting stents were used and in 42.8% patients bare metal stents. The stent was advanced over both wires, the target wire and the anchor wire. The anchor wire, which was passed through the proximal trailing strut of the stent helps to achieve precise stenting. The procedure was considered to be successful if stent was placed precisely covering the lesion and without stent loss or anchor wire prolapsing. Of the total 42 patients, the procedure was successful in 33, while failed in 9. Majority of failures were due to wire entanglement, which was fixed successfully in 3 cases by removing and reinserting the anchor wire. Out of other three failures, in one stent dislodgment occurred, stent could not cross the lesion in one and in another anchor wire got looped and prolapsed into target vessel. Conclusion This case series shows that the Szabo technique, in spite of some difficulties like wire entanglement, stent dislodgement and resistance during stent advancement, is a simple and feasible method for treating variety of ostial lesions precisely compared to conventional angioplasty. PMID:23809379

  2. 77 FR 60704 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ...] Fenestrated April 4, 2012. AAA Endovascular Graft (with the adjunctive Zenith Alignment Stent). P110029, FDA...\\ plus CoCr April 12, 2012. Coronary Stent on RX System. P110035, FDA-2012-M-0373 Boston Scientific Epic\\TM\\ Vascular Self- April 13, 2012. Corp. Expanding Stent System. P090015, FDA-2012-M-0390 Leica...

  3. An argument for the use of multiple segment stents in curved arteries.

    PubMed

    Kasiri, Saeid; Kelly, Daniel J

    2011-08-01

    Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.

  4. Canine model of acute aortic rupture: treatment with percutaneous delivery of a covered Z stent--work in progress.

    PubMed

    Williams, D M; Andrews, J C; Chee, S S; Marx, M V; Abrams, G D

    1994-01-01

    To develop a percutaneous treatment for aortic rupture with use of a covered intraluminal stent. A transmural tear was created percutaneously in the thoracic aorta in six dogs with use of a 4-mm angioplasty balloon. Gianturco Z stents were covered with polytetrafluoroethylene, loaded into a 14-F sheath, and advanced through the femoral artery to the site of injury. Within 2 minutes after initiation of the injury, the stent was deployed. Homologous canine blood was given during the procedure. Dogs that survived 24 hours were then killed. The first stent did not expand completely, and the dog died in 1 hour. At necropsy, the first two dogs (1-hour and 8-hour survival) had a large left hemothorax and extensive periaortic hematoma, indicating intrathoracic exsanguination. The next four dogs were treated with a modified stent and survived 2 hours (n = 1), 8 hours (n = 1), and 24 hours (n = 2). At necropsy hemothorax did not exceed 15 mL, and periaortic hematomas were small. The cause of death in the two early casualties with the modified stent is uncertain. There were no signs of spinal cord injury despite occlusion of three pairs of intercostal arteries. The covered Z stent (in its modified form) tamponaded the aortic tear, preventing exsanguination. Long-term studies of biocompatibility of this device appear justified.

  5. Treatment of cerebral vasospasm with self-expandable retrievable stents: proof of concept.

    PubMed

    Bhogal, Pervinder; Loh, Yince; Brouwer, Patrick; Andersson, Tommy; Söderman, Michael

    2017-01-01

    To report our preliminary experience with the use of stent retrievers to cause vasodilation in patients with delayed cerebral vasospasm secondary to subarachnoid hemorrhage. Four patients from two different high volume neurointerventional centers developed cerebral vasospasm following subarachnoid hemorrhage. In addition to standard techniques for the treatment of cerebral vasospasm, we used commercially available stent retrievers (Solitaire and Capture stent retrievers) to treat the vasospastic segment including M2, M1, A2, and A1. We evaluated the safety of this technique, degree of vasodilation, and longevity of the effect. Stent retrievers can be used to safely achieve cerebral vasodilation in the setting of delayed cerebral vasospasm. The effect is long-lasting (>24 hours) and, in our initial experience, carries a low morbidity. We have not experienced any complications using this technique although we have noted that the radial force was not sufficient to cause vasodilation in some instances. The vasospasm did not return in the vessel segments treated with stent angioplasty in any of these cases. In two of our cases stent angioplasty resulted in the reversal of focal neurological symptoms. Stent retrievers can provide long-lasting cerebral vasodilation in patients with delayed cerebral vasospasm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    PubMed

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to mitigate the increased risk of stent thrombosis associated with ACS. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions [SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT III]; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT IV]; NCT00307047; A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice: the COMPARE Trial [COMPARE]; NCT01016041). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Stent-based delivery of adeno-associated viral vectors with sustained vascular transduction and iNOS-mediated inhibition of in-stent restenosis

    PubMed Central

    Fishbein, Ilia; Guerrero, David T.; Alferiev, Ivan S.; Foster, Jonathan B.; Minutolo, Nicholas G.; Chorny, Michael; Mas Monteys, Alejandro; Driesbaugh, Kathryn H.; Nagaswami, Chandrasekaran; Levy, Robert J.

    2017-01-01

    In-stent restenosis remains an important clinical problem in the era of drug eluting stents. Development of clinical gene therapy protocols for the prevention and treatment of in-stent restenosis is hampered by the lack of adequate local delivery systems. Herein we describe a novel stent-based gene delivery platform capable of providing local arterial gene transfer with adeno-associated viral (AAV) vectors. This system exploits the natural affinity of protein G (PrG) to bind to the Fc region of mammalian IgG, making PrG a universal adaptor for surface immobilization of vector-capturing antibodies (Ab). Our results: 1) demonstrate the feasibility of reversible immobilization of AAV2 vectors using vector tethering by AAV2-specific Ab appended to the stent surface through covalently attached PrG, 2) show sustained release kinetics of PrG/Ab-immobilized AAV2 vector particles into simulated physiological medium in vitro and site-specific transduction of cultured cells, 3) provide evidence of long-term (12 weeks) arterial expression of luciferase with PrG/Ab-tethered AAV2Luc, and 4) show anti-proliferative activity and anti-restenotic efficacy of stent-immobilized AAV2iNOS in the rat carotid artery model of stent angioplasty. PMID:28832561

  8. Robot-assisted antegrade in-situ fenestrated stent grafting.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-05-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  9. Computational fluid dynamics evaluation of incomplete stent apposition in a tapered artery

    NASA Astrophysics Data System (ADS)

    Poon, Eric; Thondapu, Vikas; Ooi, Andrew; Hayat, Umair; Barlis, Peter; Moore, Stephen

    2015-11-01

    Coronary stents are deployed to prop open blocked arteries and restore normal blood flow, however in-stent restenosis (ISR) and stent thrombosis (ST) remain possibly catastrophic complications. Computational fluid dynamics (CFD) analyses can elucidate the pathological impact of alterations in coronary hemodynamics and correlate wall shear stress (WSS) with atherosclerotic processes. The natural tapering of a coronary artery often leads to proximal incomplete stent apposition (ISA) where stent struts are not in contact with the vessel wall. By employing state-of-the-art computer-aided design (CAD) software, generic open-cell and closed-cell coronary stent designs were virtually deployed in an idealised tapered coronary artery. Pulsatile blood flow (80 mL/min at 75 beats/min) was carried out numerically on these CAD models using a finite volume solver. CFD results reveal significant fluctuations in proximal WSS and large recirculation regions in the setting of proximal ISA, resulting in regions of high wall shear stress gradient (WSSG) that have been previously linked to poor endothelial cell coverage and vascular injury. The clinical significance of these proximal high WSSG regions will be correlated with findings from high-resolution in-vivo imaging. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).

  10. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de; Hegele, Axel; Rheinheimer, Stephan

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications.more » Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.« less

  11. Endoscopic bilio-duodenal bypass: outcomes of primary and revision efficacy of combined metallic stents in malignant duodenal and biliary obstructions.

    PubMed

    Canena, Jorge; Coimbra, João; Carvalho, Diana; Rodrigues, Catarina; Silva, Mário; Costa, Mariana; Horta, David; Mateus Dias, António; Seves, Isabel; Ramos, Gonçalo; Ricardo, Leonel; Coutinho, António Pereira; Romão, Carlos; Veiga, Pedro Mota

    2014-11-01

    Self-expandable metal stents (SEMSs) can be used for palliation of combined malignant biliary and duodenal obstructions. However, the results of the concomitant stent placement for the duration of the patients' lives, as well as the need for and efficacy of endoscopic revision, are unclear. This study evaluated the clinical effectiveness of SEMS placement for combined biliary and duodenal obstructions throughout the patients' lives and the need for endoscopic revision. This study is a retrospective multicenter study of 50 consecutive patients who underwent simultaneous or sequential SEMS placement for malignant biliary and duodenal obstructions. The data were collected to analyze the sustained relief of obstructive symptoms until the patients' death and the efficacy of endoscopic revision, as well as stent patency, adverse events, survival and prognostic factors for stent patency. Technical and immediate clinical success was achieved in all of the patients. Duodenal stricture occurred before the papilla in 35 patients (70 %), involved the papilla in 11 patients (22 %) and was observed distal to the papilla in four patients (8 %). Initial biliary stenting was performed endoscopically in 42 patients (84 %) and percutaneously in eight patients. After combined stenting, 30 patients (60 %) required no additional intervention until the time of their death. The remaining 20 patients were successfully treated using endoscopic stent reinsertion: nine patients needed biliary revision, three patients needed duodenal restenting and eight patients needed both biliary and duodenal reinsertion. The median duodenal stent patency and median biliary stent patency were 34 and 27 weeks, respectively. The median survival after combined stent placement was 18 weeks. A Cox multivariate analysis showed that duodenal stent obstruction after combined stenting was a risk factor for biliary stent obstruction (hazard ratio 6.85; 95 % confidence interval 1.43-198.98; P = 0.025). Endoscopic bilio-duodenal bypass is clinically effective, and the majority of the patients need no additional intervention until their death. Endoscopic revision is feasible and has a high success rate.

  12. Robot-assisted laparoscopic pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis: Variations in double-J ureteral stenting techniques.

    PubMed

    Baek, Minki; Au, Jason; Huang, Gene O; Koh, Chester J

    2017-04-01

    We describe our experience with robot-assisted laparoscopic (RAL) pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis with an emphasis on the various double J (DJ) ureteral stent placement techniques. We used our RAL pyeloureterostomy technique in two female infants with duplex systems and upper pole hydronephrosis. For case 1, we introduced the DJ stent and placed it in the recipient lower pole ureter during the robotic operation in an antegrade fashion. For case 2, we inserted the DJ stent during retrograde pyelography prior to the robotic procedure in a retrograde fashion, and the proximal portion of the stent was placed across the anastomosis into the upper pole renal pelvis. Postoperatively, each of the patients were discharged on postoperative day 1 without complications. The postoperative renal ultrasound at 3 months demonstrated marked improvement of the right upper pole hydronephrosis in both patients. RAL pyeloureterostomy represents a minimally invasive option for upper tract reconstruction of duplex systems with upper pole hydronephrosis in infants. The DJ stent can be placed at the beginning or during the procedure. The stent can be placed in the lower pole ureter or across the anastomosis into the upper pole renal pelvis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  13. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    NASA Astrophysics Data System (ADS)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  14. Development and Initial Porcine and Cadaver Experience with Three-Dimensional Printing of Endoscopic and Laparoscopic Equipment

    PubMed Central

    del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim

    2015-01-01

    Abstract Introduction: Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. Materials and Methods: We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. Results: The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (p<0.001) and lengths (p=0.001) compared to Karl Storz and Ethicon trocars (29.41, 18.06, and 17.22 mm2, respectively, and 14.29, 11.39, and 12.15 mm, respectively). Conclusions: In this pilot study, 3D printing of ureteral stents and trocars is feasible, and these devices can be deployed in the porcine and cadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future. PMID:24983138

  15. Development and initial porcine and cadaver experience with three-dimensional printing of endoscopic and laparoscopic equipment.

    PubMed

    del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim; Landman, Jaime

    2015-01-01

    Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (p<0.001) and lengths (p=0.001) compared to Karl Storz and Ethicon trocars (29.41, 18.06, and 17.22 mm(2), respectively, and 14.29, 11.39, and 12.15 mm, respectively). In this pilot study, 3D printing of ureteral stents and trocars is feasible, and these devices can be deployed in the porcine and cadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future.

  16. TOKYO criteria 2014 for transpapillary biliary stenting.

    PubMed

    Isayama, Hiroyuki; Hamada, Tsuyoshi; Yasuda, Ichiro; Itoi, Takao; Ryozawa, Shomei; Nakai, Yousuke; Kogure, Hirofumi; Koike, Kazuhiko

    2015-01-01

    It is difficult to carry out meta-analyses or to compare the results of different studies of biliary stents because there is no uniform evaluation method. Therefore, a standardized reporting system is required. We propose a new standardized system for reporting on biliary stents, the 'TOKYO criteria 2014', based on a consensus among Japanese pancreatobiliary endoscopists. Instead of stent occlusion, we use recurrent biliary obstruction, which includes occlusion and migration. The time to recurrent biliary obstruction was estimated using Kaplan-Meier analysis with the log-rank test. We can evaluate both plastic and self-expandable metallic stents (uncovered and covered). We also propose specification of the cause of recurrent biliary obstruction, identification of complications other than recurrent biliary obstruction, indication of severity, measures of technical and clinical success, and a standard for clinical care. Most importantly, the TOKYO criteria 2014 allow comparison of biliary stent quality across studies. Because blocked stents can be drained not only using transpapillary techniques but also by an endoscopic ultrasonography-guided transmural procedure, we should devise an evaluation method that includes transmural stenting in the near future. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  17. Cost-effectiveness and clinical efficacy of biliary stents in patients undergoing neoadjuvant therapy for pancreatic adenocarcinoma in a randomized controlled trial.

    PubMed

    Gardner, Timothy B; Spangler, Chad C; Byanova, Katerina L; Ripple, Gregory H; Rockacy, Matthew J; Levenick, John M; Smith, Kerrington D; Colacchio, Thomas A; Barth, Richard J; Zaki, Bassem I; Tsapakos, Michael J; Gordon, Stuart R

    2016-09-01

    The optimal type of stent for the palliation of malignant biliary obstruction in patients with pancreatic adenocarcinoma undergoing neoadjuvant chemoradiotherapy with curative intent is unknown. We performed a prospective trial comparing 3 types of biliary stents-fully covered self-expandable metal (fcSEMS), uncovered self-expandable metal (uSEMS), and plastic-to determine which best optimized cost-effectiveness and important clinical outcomes. In this prospective randomized trial, consecutive patients with malignant biliary obstruction from newly diagnosed pancreatic adenocarcinoma who were to start neoadjuvant chemoradiotherapy were randomized to receive fcSEMSs, uSEMSs, or plastic stents during the index ERCP. The primary outcomes were time to stent occlusion, attempted surgical resection, or death after the initiation of neoadjuvant therapy, and the secondary outcomes were total patient costs associated with the stent, including the index ERCP cost, downstream hospitalization cost due to stent occlusion, and the cost associated with procedural adverse event. Fifty-four patients were randomized and reached the primary end point: 16 in the fcSEMS group, 17 in the uSEMS group, and 21 in the plastic stent group. No baseline demographic or tumor characteristic differences were noted among the groups. The fcSEMSs had a longer time to stent occlusion compared with uSEMSs and plastic stents (220 vs 74 and 76 days, P < .01), although the groups had equivalent rates of stent occlusion, attempted surgical resection, and death. Although SEMS placement cost more during the index ERCP (uSEMS = $24,874 and fcSEMS = $22,729 vs plastic = $18,701; P < .01), they resulted in higher procedural AE costs per patient (uSEMS = $5522 and fcSEMS = $12,701 vs plastic = $0; P < .01). Conversely, plastic stents resulted in an $11,458 hospitalization cost per patient due to stent occlusion compared with $2301 for uSEMSs and $0 for fcSEMSs (P < .01). In a prospective trial comparing fcSEMSs, uSEMSs, and plastic stents for malignant biliary obstruction in patients undergoing neoadjuvant therapy with curative intent for pancreatic adenocarcinoma, no stent type was superior in optimizing cost-effectiveness, although fcSEMSs resulted in fewer days of neoadjuvant treatment delay and a longer time to stent occlusion. (Clincial trial registration number: NCT01038713.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilhelm, K.E., E-mail: wilhelm@uni-bonn.de; Grabolle, B.; Urbach, H.

    2006-10-15

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted withoutmore » major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency.« less

  19. High-definition computed tomography for coronary artery stents imaging compared with standard-definition 64-row multidectector computed tomography: an initial in vivo study.

    PubMed

    Yang, Wen Jie; Zhang, Huan; Xiao, Hua; Li, Jian Ying; Liu, Yan; Pan, Zi Lai; Chen, Ke Min

    2012-01-01

    The evaluation of coronary stents by computed tomography (CT) remains difficult. We assessed the imaging performance of a high-definition CT scanner (HDCT) by comparing with a conventional 64-row standard-definition CT (SDCT). One hundred thirty-eight consecutive stented patients underwent coronary CT angiography, among whom 66 patients were examined by HDCT, and 72 patients by SDCT (LightSpeed VCT XT; GE Healthcare, Waukesha, Wis). The image quality score, the inner stent diameter (ISD), and the radiation dose were analyzed. All data were statistically tested by SPSS 13.0 software (SPSS Inc, Chicago, Ill). In 72 patients examined using SDCT, 135 stents were detected; in 66 patients examined using HDCT, 119 stents were detected. The image quality score on HDCT was significantly better than that on SDCT (1.4 [SD, 0.7] vs 1.9 [SD, 0.8]). The ISD on HDCT was significantly higher than that on SDCT (1.8 [SD, 0.5] vs 1.6 [SD, 0.4]). There was no significant difference of either image quality score or ISD between the HDCT and SDCT groups in stents with 2.5-mm diameter. Images on HDCT showed significantly better image quality score and larger ISD than images on SDCT in 2.75-, 3-, and 3.5-mm stents. For patients examined by retrospective electrocardiogram-gated technique, the radiation dose on HDCT was significantly lower than that on SDCT (11.3 [SD, 2.9] vs 15.1 [SD, 3.8] mSv). High-definition CT scanner offered improved image quality and measurement accuracy for imaging coronary stents compared with conventional SDCT, providing higher spatial resolution and lower dose for evaluating coronary stents with 2.75- to 3.5-mm diameter.

  20. In vitro comparison of intracranial stent visibility using various concentrations of gadolinium contrast agent under 1.5 T and 3 T MR angiography.

    PubMed

    Chiang, Chen-Hua; Tseng, Ying-Chi; Chen, Ai-Chi; Huang, Yen-Lin; Chen, David Yen-Ting; Chen, Chi-Jen; Lin, Yen-Kuang; Hsu, Hui-Ling

    2017-04-01

    MR angiography (MRA) is an increasingly used evaluation method following intracranial stenting. However, the various artifacts created by the stent limit this technique. The purpose of this study was to investigate the effects of various concentrations of gadolinium contrast agent on the visibility and signal characteristics of two stents using the a contrast enhanced MRA technique. Two intracranial stents (Enterprise and Helistent) were placed in polyvinyl chloride tubes as vascular phantoms. They were filled with six different doses of gadolinium contrast agent (1.0, 2.0, 4.0, 6.0, 8.0, and 10.0 mmol/L dimeglumine gadopentetate, respectively) and imaged using 3 T and 1.5 T MR systems. Relative in-stent signal (RIS) was calculated and artificial luminal narrowing (ALN) was obtained using pixel by pixel analysis. The Enterprise stent, performed in both 1.5 T and 3 T MR systems, showed mean RIS values much less than those for the Helistent for all different doses of gadolinium solution. Increased gadolinium concentration resulted in a gradual reduction in RIS values in the Enterprise group. Also, ALN in the Enterprise group showed no or little change with various gadolinium doses. The Enterprise stent demonstrated good luminal visibility regardless of gadolinium concentration. The relative in-stent signals were more predictable in the Enterprise stent with various doses of gadolinium. Therefore, the Enterprise stent has been shown to provide better in-stent visibility compared with the Helistent using various gadolinium doses. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Treatment of esophageal anastomotic leakage with self-expanding metal stents: analysis of risk factors for treatment failure

    PubMed Central

    Persson, Saga; Rouvelas, Ioannis; Kumagai, Koshi; Song, Huan; Lindblad, Mats; Lundell, Lars; Nilsson, Magnus; Tsai, Jon A.

    2016-01-01

    Background and study aim: The endoscopic placement of self-expandable metallic esophageal stents (SEMS) has become the preferred primary treatment for esophageal anastomotic leakage in many institutions. The aim of this study was to investigate possible risk factors for failure of SEMS-based therapy in patients with esophageal anastomotic leakage. Patients and methods: Beginning in 2003, all patients with an esophageal leak were initially approached and assessed for temporary closure with a SEMS. Until 2014, all patients at the Karolinska University Hospital with a leak from an esophagogastric or esophagojejunal anastomosis were identified. Data regarding the characteristics of the patients and leaks and the treatment outcomes were compiled. Failure of the SEMS treatment strategy was defined as death due to the leak or a major change in management strategy. The risk factors for treatment failure were analyzed with simple and multivariable logistic regression statistics. Results: A total of 447 patients with an esophagogastric or esophagojejunal anastomosis were identified. Of these patients, 80 (18 %) had an anastomotic leak, of whom 46 (58 %) received a stent as first-line treatment. In 29 of these 46 patients, the leak healed without any major change in treatment strategy. Continuous leakage after the application of a stent, decreased physical performance preoperatively, and concomitant esophagotracheal fistula were identified as independent risk factors for failure with multivariable logistic regression analysis. Conclusion: Stent treatment for esophageal anastomotic leakage is successful in the majority of cases. Continuous leakage after initial stent insertion, decreased physical performance preoperatively, and the development of an esophagotracheal fistula decrease the probability of successful treatment. PMID:27092321

  2. Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography.

    PubMed

    Kitahara, Hideki; Waseda, Katsuhisa; Yamada, Ryotaro; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Kobayashi, Yuhei; Okada, Kozo; Kume, Teruyoshi; Nakagawa, Kaori; Teramoto, Tomohiko; Ikeno, Fumiaki; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2016-06-12

    Our aim was to evaluate stent expansion and acute recoil at deployment and post-dilatation, and the impact of post-dilatation strategies on final stent dimensions. Optical coherence tomography (OCT) was performed on eight bare metal platforms of drug-eluting stents (3.0 mm diameter, n=6 for each) during and after balloon inflation in a silicone mock vessel. After nominal-pressure deployment, a single long (30 sec) vs. multiple short (10 sec x3) post-dilatations were performed using a non-compliant balloon (3.25 mm, 20 atm). Stent areas during deployment with original delivery systems were smaller in stainless steel stents than in cobalt-chromium and platinum-chromium stents (p<0.001), whereas subsequent acute recoil was comparable among the three materials. At post-dilatation, acute recoil was greater in cobalt-chromium and platinum-chromium stents than in stainless steel stents (p<0.001), resulting in smaller final stent areas in cobalt-chromium and platinum-chromium stents than in stainless steel stents (p<0.001). In comparison between conventional and latest-generation cobalt-chromium stents, stent areas were not significantly different after both deployment and post-dilatation. With multiple short post-dilatations, acute recoil was significantly improved from first to third short inflation (p<0.001), achieving larger final area than a single long inflation, despite stent materials/designs (p<0.001). Real-time OCT revealed significant acute recoil in all stent types. Both stent materials/designs and post-dilatation strategies showed a significant impact on final stent expansion.

  3. [Complications and the management of fully covered retrievable metal stent placement in benign tracheal stenosis].

    PubMed

    Wang, Zheng-yu; Wang, Yong-li; Chen, Guang-li; Liang, Xi-hong; Wang, Zhen-chang; Ma, Jian-zhong; Wu, Guang-zhong; Zhang, Xiao-ping

    2012-11-01

    To study complications and the management of the use of covered retrievable expandable metallic stents in the treatment of benign tracheal stenosis. Fully covered retrievable metal stents were placed in 21 patients with benign tracheal stenosis. Stent-related complications and the management were reviewed and analysed. Twenty-eight fully covered retrievable metallic stents were successfully placed fluoroscopically in 21 patients. Stents were removed 4 - 12 months [mean (5.5 ± 2.2) mouths] after placement in all patients. Stent-related complications included granulation tissue (n = 18), stent migration (n = 4), stent expectoration (n = 2), halitosis (n = 8), mucous retention (n = 21) and mucus plugging (n = 1). Granulation tissue was removed with a carbon dioxide laser in 2 patients. Stents were replaced for 2 times and 3 times respectively in 2 patients after stent migration and stent expectoration. An additional stent was placed in 2 patients after stent migration. Symptom of halitosis was relieved after prolonged course of systemic antibiotics treatment in 8 patients. Symptom of mucous retention was relieved with nebulized saline and N-acetylcysteine saline inhalation. Mucous plug was expelled after severe coughing after suctioning using an aspirator in one patient. There were statistically significant differences in stricture diameter, rank of tachypnea and pulmonary function (FEV(1)) in all 21 patients before stent insertion and after stents removal. No patient has experienced recurrence during the follow-up period of 1 - 36 months [mean (23.2 ± 8.0) months]. Fully covered retrievable metallic stent may be a safe and effective in benign tracheal stenosis. Stent-related complications may be effectively managed.

  4. Use of a nitinol stent to palliate a colorectal neoplastic obstruction in a dog

    PubMed Central

    Culp, William T. N.; MacPhail, Catriona M.; Perry, James A.; Jensen, Tracey D.

    2015-01-01

    Case Description A 12-year-old castrated male Labrador Retriever was evaluated for clinical signs associated with colorectal obstruction. Clinical Findings The dog had a 2-week history of tenesmus and hematochezia. On rectal examination, an annular colorectal mass was palpable extending orad into the pelvic canal. The original diagnosis of the colorectal mass was a mucosal adenoma. The dog was maintained on a low-residue diet and fecal softeners for a period of 13 months after initial diagnosis. At that time, medical management was no longer effective. Treatment and Outcome Placement of a colonic stent was chosen to palliate the clinical signs associated with colorectal obstruction. By use of fluoroscopic and colonoscopic guidance, a nitinol stent was placed intraluminally to open the obstructed region. Placement of the stent resulted in improvement of clinical signs, although tenesmus and obstipation occurred periodically after stent placement. At 212 days after stent placement, the patient had extensive improvement in clinical signs with minimal complications; however, clinical signs became severe at 238 days after stent placement, and the dog was euthanized. Histologic evaluation of the rectal tumor from samples obtained during necropsy revealed that the tumor had undergone malignant transformation to a carcinoma in situ. Clinical Relevance A stent was successfully placed in the colon and rectum to relieve obstruction associated with a tumor originally diagnosed as a benign neoplasm. Placement of colorectal stents may be an option for the palliation of colorectal obstruction secondary to neoplastic disease; however, clinical signs may persist, and continuation of medical management may be necessary. PMID:21756178

  5. Treatment of Postoperative Leaks of the Upper Gastrointestinal Tract with Colonic Self-Expandable Metal Stents.

    PubMed

    Sousa, Paula; Castanheira, António; Martins, Diana; Pinho, Juliana; Araújo, Ricardo; Cancela, Eugénia; Ministro, Paula; Silva, Américo

    2017-07-01

    The use of self-expandable metal stents (SEMS) for the treatment of postoperative leaks of the upper gastrointestinal tract is already established. However, there are discrepancies between the relatively small caliber of the esophageal stents available and the postsurgical luminal size, which may determine an inadequate juxtaposition. As colonic stents have a bigger diameter, they might be more adequate. Additionally, stents with a larger diameter might have a lower risk of migration. The aim of this study was to evaluate the efficacy and complications associated with the use of colonic fully covered SEMS (FSEMS) in the treatment of postoperative leaks in critical patients. All patients with postoperative leaks of the upper gastrointestinal tract treated with colonic stents (Hanarostent® CCI) between 2010 and 2013 were retrospectively included. Four patients with postoperative leaks were treated with colonic SEMS. The underlying surgeries were a gastric bypass, an esophagogastrectomy for Boerhaave syndrome, a primary repair of esophagopleural fistula due to Boerhaave syndrome, and an esophagectomy due to esophageal cancer. The leaks were detected on average 17 days after the initial surgery. All patients needed admission to a critical care unit after index surgery. Stent placement was technically feasible in all patients. The median residence time of the stents was 7 weeks, and no complications were verified when they were removed. There were no cases of stent migration. The treatment was successful in all patients, with complete healing of the leaks. The placement of colonic FSEMS seems to be successful and safe in the treatment of postoperative leaks of the upper gastrointestinal tract.

  6. Initial clinical application of a robotically steerable catheter system in endovascular aneurysm repair.

    PubMed

    Riga, Celia; Bicknell, Colin; Cheshire, Nicholas; Hamady, Mohamad

    2009-04-01

    To report the initial clinical use of a robotically steerable catheter during endovascular aneurysm repair (EVAR) in order to assess this novel and innovative approach in a clinical setting. Following a series of in-vitro studies and procedure rehearsals using a pulsatile silicon aneurysm model, a 78-year-old man underwent robot-assisted EVAR of a 5.9-cm infrarenal abdominal aortic aneurysm. During the standard procedure, a 14-F remotely steerable robotic catheter was used to successfully navigate through the aneurysm sac, cannulate the contralateral limb of a bifurcated stent-graft under fluoroscopic guidance, and place stiff wires using fine and controlled movements. The procedure was completed successfully. There were no postoperative complications, and computed tomographic angiography prior to discharge and at 3 months confirmed that the stent-graft remained in good position, with no evidence of an endoleak. EVAR using robotically-steerable catheters is feasible. This technology may simplify more complex procedures by increasing the accuracy of vessel cannulation and perhaps reduce procedure times and radiation exposure to the patient and operator.

  7. When is prior ureteral stent placement necessary to access the upper urinary tract in prepubertal children?

    PubMed

    Corcoran, Anthony T; Smaldone, Marc C; Mally, Dev; Ost, Michael C; Bellinger, Mark F; Schneck, Francis X; Docimo, Steven G; Wu, Hsi-Yang

    2008-10-01

    We studied the possibility that age, height, weight and body mass index could be used to predict the likelihood of successful ureteroscopic access to the upper urinary tract without previous stent placement in prepubertal children. We retrospectively reviewed all ureteroscopic procedures for upper tract calculi in prepubertal children from 2003 to 2007. We compared age, height, weight and body mass index in patients who underwent successful primary flexible ureteroscopic access and in those who required initial stent placement to perform ureteroscopy. Successful primary ureteroscopic access to the upper tract was achieved in 18 of 30 patients (60%). There was no difference in mean age (9.9 vs 9.5 years, p = 0.8), height (132 vs 128 cm, p = 0.6), weight (37 vs 36 kg, p = 0.86) or body mass index (19.3 vs 20.5 kg/m(2), p = 0.55) between patients with successful vs unsuccessful upper tract access. Locations that prevented access to the upper urinary tract were evenly distributed among the ureteral orifice, iliac vessels and ureteropelvic junction. Age, height, weight and body mass index could not predict the likelihood of successful ureteroscopic access to the upper tract. Placement of a ureteral stent for passive ureteral dilation is not necessary for successful ureteroscopic access to the renal pelvis in prepubertal children. An initial attempt at ureteroscopy, with placement of a ureteral stent if upper tract access is unsuccessful, decreases the number of procedures while maintaining a low complication rate.

  8. An uncommon case of antegrade stent causing serious persistent haematuria

    PubMed Central

    Ejikeme, Chidozie M.

    2015-01-01

    Introduction Transient minor bleeding after nephrostomy tube placement is very common, occurring in up to 95% of cases. Often this is due to small vessel or venous bleeding. Severe post procedure bleeding requiring transfusion or other intervention is RARE. Presentation of case A case of a 79 year old man, who had antegrade stent insertion for 10 mm left upper ureteric stone. He was alright for up to one week but developed severe haemturia requiring three way catheter. Catheter was blocking regularly and needed to go to theatre for bladder washout. No source of bleeding was found in bladder. CT renal angiogram revealed his stent has migrated into the nephrostomy tract. He was taken to theatre and had his stent changed. His haematuria settled. Discussion The severe bleeding recorded in this case could not have been attributed to the stent, though the initial bleeding following the procedure has settled it seemed likely to blame vascular injury following PCN as the cause of bleeding. Subsequent CT scan was able to point at the right source of bleeding. Conclusion All possibilities should be considered when presented with a case severe bleeding following antegrade stent insertion. PMID:25797353

  9. An uncommon case of antegrade stent causing serious persistent haematuria.

    PubMed

    Ejikeme, Chidozie M

    2015-01-01

    Transient minor bleeding after nephrostomy tube placement is very common, occurring in up to 95% of cases. Often this is due to small vessel or venous bleeding. Severe post procedure bleeding requiring transfusion or other intervention is RARE. A case of a 79 year old man, who had antegrade stent insertion for 10mm left upper ureteric stone. He was alright for up to one week but developed severe haemturia requiring three way catheter. Catheter was blocking regularly and needed to go to theatre for bladder washout. No source of bleeding was found in bladder. CT renal angiogram revealed his stent has migrated into the nephrostomy tract. He was taken to theatre and had his stent changed. His haematuria settled. The severe bleeding recorded in this case could not have been attributed to the stent, though the initial bleeding following the procedure has settled it seemed likely to blame vascular injury following PCN as the cause of bleeding. Subsequent CT scan was able to point at the right source of bleeding. All possibilities should be considered when presented with a case severe bleeding following antegrade stent insertion. Copyright © 2015 The Author. Published by Elsevier Ltd.. All rights reserved.

  10. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report.

    PubMed

    Kumagai, Hozumi; Nio, Kenta; Shirakawa, Tsuyoshi; Uchino, Keita; Kusaba, Hitoshi; Isobe, Taichi; Komoda, Masato; Tamura, Shingo; Maeyama, Ryo; Nagai, Eishi; Akashi, Koichi; Baba, Eishi

    2012-09-19

    Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient's general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  11. The PARAGON stent study: a randomized trial of a new martensitic nitinol stent versus the Palmaz-Schatz stent for treatment of complex native coronary arterial lesions.

    PubMed

    Holmes, D R; Lansky, A; Kuntz, R; Bell, M R; Buchbinder, M; Fortuna, R; O'Shaughnessy, C D; Popma, J

    2000-11-15

    A new martensitic nitinol stent with improved flexibility and radiopacity was tested to evaluate whether these differences improve initial or long-term outcome. Patients who underwent percutaneous revascularization of a discrete native coronary lesion were randomly assigned to the new stent (PARAGON, n = 349) or to the first-generation Palmaz-Schatz (PS) stent (n = 339). The primary end point was target vessel failure at 6 months (a composite of cardiac or noncardiac death, any infarction in the distribution of the treated vessel, or clinically indicated target vessel revascularization). Secondary end points were, among others, device and procedural success and angiographic restenosis. Mean age was 62 years; diabetes was present in 21% of patients, prior bypass surgery in 6%, and recent infarction in 22% (p = NS for comparison between the 2 randomized arms). The PARAGON stent group had smaller reference vessels (2.97 vs 3.05 mm, p = 0.05), more prior restenosis (8.0% vs 4.5%, p = 0.07), and a longer average stent length (21.3 vs 19.4 mm, p < 0.05). Device success was significantly higher in the PARAGON arm (99.1% vs 94.3%, p < 0.05). Death and infarction at 6-month follow-up were infrequent in both groups. There was no significant difference in death (2.0% vs 1.2%, p = 0.546), but a higher rate of infarction for the PARAGON cohort (9.2% vs 4.7%, p = 0.025). Although target vessel failure (20.3% vs 12.4%, p = 0.005) and target lesion revascularization (12.0% vs 5.9%, p = 0.005) were higher in the PARAGON group, there was no significant difference in 6-month follow-up in in-stent minimal lumen diameter or in the rate of binary angiographic restenosis. Both PARAGON and PS stents are safe and associated with infrequent adverse events. The PARAGON stent can be delivered more frequently than the first-generation PS stent. Although there was no significant difference in in-stent minimal lumen diameter or the frequency of angiographic restenosis, clinical restenosis was more frequent in the PARAGON group.

  12. Stenting of aortic coarctation: acute, intermediate, and long-term results of a prospective multi-institutional registry--Congenital Cardiovascular Interventional Study Consortium (CCISC).

    PubMed

    Holzer, Ralf; Qureshi, Shakeel; Ghasemi, Abdolrahim; Vincent, Julie; Sievert, Horst; Gruenstein, Daniel; Weber, Howard; Alday, Luis; Peirone, Alejandro; Zellers, Thomas; Cheatham, John; Slack, Michael; Rome, Jonathan

    2010-10-01

    Since the 1980s, stent implantation has evolved as an important therapeutic strategy for coarctation of the aorta. However, available data is frequently flawed by short follow-up, lack of adequate follow-up imaging, and retrospective nature of data collection. Data was prospectively collected using a multicenter registry congenital cardiovascular interventional study consortium (CCISC). Between 2000 and 2009, 302 patients from 34 centers with a median weight of 58 kg underwent stent implantation for coarctation. Eligible patients (44%) completed intermediate follow-up (3-18 months) with integrated imaging (cath, CT, MRI), whereas 21% completed long-term follow-up (>18-60 months). Procedural success was defined as UL/LL systolic gradient of less than 20 mm Hg, lack of significant recurrent obstruction, and freedom from unplanned repeat intervention. Acute procedural success was 96%. Cumulative intermediate success was 86%, and cumulative long-term success was 77%. Unplanned repeat interventions were required in 4%, and aortic wall complications were seen in 1% of patients (dissection n = 1 and aneurysm n = 3). Other adverse events (n = 15) occurred mainly acutely and included technical complications such as stent malposition (n = 9). At long-term follow-up, 23% of patients continued to have systolic blood pressure above the 95th centile, 9% had an upper-to-lower limb blood pressure gradient in excess of 20 mm Hg, and 32% were taking antihypertensive medication. This study documented acute, intermediate, and long-term outcome data comparable or superior with other surgical or interventional series. However, even with successful initial stent therapy, patients continue to require long-term follow-up and have associated long-term morbidity, relating to aortic wall complications, systemic hypertension, recurrent obstruction as well as need for repeat intervention. © 2010 Wiley-Liss, Inc.

  13. Medical Devices; Gastroenterology-Urology Devices; Classification of the Metallic Biliary Stent System for Benign Strictures. Final order.

    PubMed

    2016-07-13

    The Food and Drug Administration (FDA) is classifying the metallic biliary stent system for benign strictures into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the metallic biliary stent system for benign strictures' classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  14. Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound.

    PubMed

    Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J

    2006-08-15

    Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.

  15. The use of self-expanding silicone stents in esophageal cancer care: optimal pre-, peri-, and postoperative care.

    PubMed

    Martin, Robert; Duvall, Ryan; Ellis, Susan; Scoggins, Charles R

    2009-03-01

    Preoperative nutritional supplementation, management of esophageal leaks, and postoperative anastomotic strictures still remain common problems in the management of esophageal cancer. Jejunal feeding tubes, total parenteral nutrition (TPN) with nasogastric suction, and repeated esophageal dilations remain the most common treatments, respectively. The aim of this study was to evaluate the use of removable silicone stents in (1) the preoperative nutritional optimization during neoadjuvant therapy, (2) the management of perioperative anastomotic leak, and (3) the management of postoperative anastomotic strictures. Review of our prospectively maintained esophageal database identified 15 patients who had removable self-expanding silicone stents placed in the management of one of these three management problems from July 2004 to August 2006. Preoperative therapy: Five patients underwent initial stent placement in preparation for neoadjuvant therapy. Dysphagia relief was seen in 100% of patients, with optimal caloric needs taken within 24 h of placement. All patients tolerated neoadjuvant therapy without delay from dehydration or malnutrition. One stent migration was found at the time of operation, which was removed without sequelae. Perioperative therapy: Five patients developed delayed (>10 days) esophageal leaks that were managed with removable esophageal stent and percutaneous drainage (in three patients). All patients had successful exclusion of the leak on the day of the procedure with resumption of oral intake on the evening of procedure. All five healed leaks without sequelae. Postoperative therapy: Five patients developed postoperative anastomotic strictures that required dilation and placement of removable esophageal stent. The median number of dilations was 1 (range 1-2), with all stents placed for approximate 3 months duration. All patients had immediate dysphagia relief after stent placement. Removable esophageal stents are novel treatment option to optimize relief of symptoms and return the patients back to a more normal oral intake. Continued evaluation is needed to consider stent use as first-line therapy.

  16. [Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation].

    PubMed

    Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R

    2005-01-01

    To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.

  17. A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent: The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet).

    PubMed

    Schofer, Joachim; Musiałek, Piotr; Bijuklic, Klaudija; Kolvenbach, Ralf; Trystula, Mariusz; Siudak, Zbigniew; Sievert, Horst

    2015-08-17

    This study sought to evaluate the feasibility of the CGuard Carotid Embolic Protective Stent system-a novel thin strut nitinol stent combined with a polyethylene terephthalate mesh covering designed to prevent embolic events from the target lesion in the treatment of carotid artery lesions in consecutive patients suitable for carotid artery stenting. The risk of cerebral embolization persists throughout the carotid artery stenting procedure and remains during the stent healing period. A total of 30 consecutive patients (age 71.6 ± 7.6 years, 63% male) meeting the conventional carotid artery stenting inclusion criteria were enrolled in 4 centers in Germany and Poland. The primary combined endpoint was the procedure success of the CGuard system and the number and volume of new lesions on the ipsilateral side assessed by diffusion-weighted magnetic resonance imaging at 48 h post-procedure and at 30 days. The secondary endpoint was 30-day major adverse cardiac or cerebrovascular events (death, stroke, or myocardial infarction). Protection devices were used in all procedures. Procedure success was 100%, with 0% procedural complications. The 30-day major adverse cardiac or cerebrovascular events rate was 0%. New ipsilateral ischemic lesions at 48 h occurred in 37.0% of patients and the average lesion volume was 0.039 ± 0.08 cm(3). The 30-day diffusion-weighted magnetic resonance imaging showed complete resolution of all but 1 periprocedural lesion and only 1 new minor (0.116 cm(3)) lesion in relation to the 48-h scan. The use of the CGuard system in patients undergoing carotid artery stenting is feasible. In addition, the benefit of using CGuard may extend throughout the stent healing period. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. [Anesthetic management of tracheobronchial stent insertion in patients who underwent laser resection, balloon dilatation and tracheostomy in advance].

    PubMed

    Hirai, Akiko; Hirose, Yoshifumi; Gamoh, Masahiro; Satoh, Minako

    2005-10-01

    We report successful management of tracheobronchial stent insertion under general anesthesia. In thirty-two cases, tracheobronchial stent insertion was performed under general anesthesia. The technique for airway management was chosen depending on the type of stent or the constriction level of the airway portion. We employed tracheostomy in order to avoid repeated intubations during the insertion of Dumon or Dynamic stent. In case of severe airway stenosis, laser resection or balloon dilatation was performed before stent insertion. We had 32 successful cases in 36 trials. Four trials failed due to insufficient expansion in one, mismatches of stent angle in one and pneumomediastinum in one. There was no exacerbation of respiratory condition in failed cases. There was no case who needed percutaneous cardiopulmonary support system. We managed tracheobronchial stent insertion under general anesthesia. Both the airway expansion by laser resection or balloon dilatation before stent insertion and also the insertion of Dumon or Dynamic stent through a tracheostomy were helpful strategies. These techniques facilitated more definitive airway maintenance and stable anesthetic management.

  19. Resolution of Metallic Biliary Stent Allergic Reaction After Partial Stent Removal in a Patient with Nickel Sensitivity.

    PubMed

    Esparaz, Anthony M; Ahmed, Muneeb

    2017-07-01

    Local and systemic reactions to implanted metallic devices, particularly to those containing nickel, are well documented. Metal ions are released due to exposure of the metal to blood, proteins, other body fluids, and sheer mechanical stress. Metal ions then complex with native proteins and become antigens, which can elicit hypersensitivity reactions. Another case report depicts a specific allergic complication (early stent occlusion) related to metallic biliary stent implantation. We present a case of allergic symptoms, associated with eating, in a patient who developed nickel sensitivity after biliary metal stent placement confirmed by allergic skin testing to the same metallic biliary stent placed one year earlier. Symptoms resolved following partial removal of the non-epithelialized portion of the biliary stent.

  20. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents.

    PubMed

    Teichgräber, Ulf K; de Bucourt, Maximilian

    2012-01-01

    OJECTIVES: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Renal artery stenosis in children: therapeutic percutaneous balloon and stent angioplasty.

    PubMed

    Colyer, Jessica H; Ratnayaka, Kanishka; Slack, Michael C; Kanter, Joshua P

    2014-06-01

    Renal artery stenosis (RAS) accounts for 10 % of cases of systemic hypertension in children. Initial management involves anti-hypertensive therapy. Percutaneous interventions are documented for the treatment of RAS in the adult population. In children, case reports suggest benefit. This is a retrospective analysis of consecutive patients referred for catheterization for RAS between 2002 and 2010 at a single institution. Recorded variables included: age, weight, systemic blood pressure, minimal luminal diameter, interventional devices, antihypertensive medications, contrast volume, and complications. Twelve patients (median age 8.2, IQR 6-12.4 years); median weight 42.8 kg, IQR: 25-47.4 kg) were referred for renal artery catheterization and underwent percutaneous intervention. Overall, minimal luminal diameter (MLD) increased by 1.2 ± 0.9 mm for all patients (p < 0.05) and by 1.3 ± 0.9 mm for post-renal transplant patients (p < 0.05). Only stent angioplasty patients demonstrated significant improved blood pressure (p < 0.05). One patient had stent thrombosis requiring re-intervention with repeat balloon angioplasty. This retrospective analysis suggests that percutaneous intervention might play a role in the management of RAS, with an improvement in MLD in children with RAS. Transcatheter intervention is technically feasible with low morbidity. A prospective, longitudinal study is warranted to compare standard medical therapy with percutaneous interventions.

  2. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    PubMed

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  3. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.

    PubMed

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Kudo, Taiki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-02-01

    Bilateral self-expandable metallic stent (SEMS) placement for the management of unresectable malignant hilar biliary obstruction (UMHBO) is technically challenging to perform using the existing metallic stents with thick delivery systems. The recently developed 6-Fr delivery systems could facilitate a single-step simultaneous side-by-side placement through the accessory channel of the duodenoscope. The aim of this study was to evaluate the feasibility of this procedure. Between May and September 2013, 13 consecutive patients with UMHBO underwent a single-step simultaneous side-by-side placement of SEMS with the 6-Fr delivery system. The technical success rate, stent patency, and rate of complications were evaluated from the prospectively collected database. Technical success was achieved in 11 (84.6%, 95% confidence interval [CI]: 57.8-95.8) patients. The median procedure time was 25 min. Early and late complications were observed in 23% (one segmental cholangitis and two liver abscesses) and 15% (one segmental cholangitis and one cholecystitis) patients, respectively. Median dysfunction free patency was 263 days (95% CI: 37-263). Five patients (38%) experienced stent occlusion that was successfully managed by endoscopic stent placement. A single-step simultaneous side-by-side placement of SEMS with a 6-Fr delivery system was feasible for the management of UMHBO. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  4. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riga, Celia V., E-mail: c.riga@imperial.ac.uk; Bicknell, Colin D.; Wallace, Daniel

    2009-05-15

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged formore » a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.« less

  5. Esophageal stenting for benign and malignant disease: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

    PubMed

    Spaander, Manon C W; Baron, Todd H; Siersema, Peter D; Fuccio, Lorenzo; Schumacher, Brigitte; Escorsell, Àngels; Garcia-Pagán, Juan-Carlos; Dumonceau, Jean-Marc; Conio, Massimo; de Ceglie, Antonella; Skowronek, Janusz; Nordsmark, Marianne; Seufferlein, Thomas; Van Gossum, André; Hassan, Cesare; Repici, Alessandro; Bruno, Marco J

    2016-10-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE), endorsed by the European Society for Radiotherapy and Oncology (ESTRO), the European Society of Digestive Endoscopy (ESDO), and the European Society for Clinical Nutrition and Metabolism (ESPEN). The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations for malignant disease 1 ESGE recommends placement of partially or fully covered self-expandable metal stents (SEMSs) for palliative treatment of malignant dysphagia over laser therapy, photodynamic therapy, and esophageal bypass (strong recommendation, high quality evidence). 2 For patients with longer life expectancy, ESGE recommends brachytherapy as a valid alternative or in addition to stenting in esophageal cancer patients with malignant dysphagia. Brachytherapy may provide a survival advantage and possibly a better quality of life compared to SEMS placement alone. (Strong recommendation, high quality evidence.) 3 ESGE recommends esophageal SEMS placement as the preferred treatment for sealing malignant tracheoesophageal or bronchoesophageal fistula (strong recommendation, low quality evidence). 4 ESGE does not recommend the use of concurrent external radiotherapy and esophageal stent treatment. SEMS placement is also not recommended as a bridge to surgery or prior to preoperative chemoradiotherapy. It is associated with a high incidence of adverse events and alternative satisfactory options such as placement of a feeding tube are available. (Strong recommendation, low quality evidence.) Main recommendations for benign disease 1 ESGE recommends against the use of self-expandable stents (SEMSs) as first-line therapy for the management of benign esophageal strictures because of the potential for adverse events, the availability of alternative therapies, and costs (strong recommendation, low quality evidence). 2 ESGE suggests consideration of temporary placement of SEMSs as therapy for refractory benign esophageal strictures (weak recommendation, moderate evidence). Stents should usually be removed at a maximum of 3 months (strong recommendation, weak quality evidence). 3 ESGE suggests that fully covered SEMSs be preferred over partially covered SEMSs for the treatment of refractory benign esophageal strictures, because of their lack of embedment and ease of removability (weak recommendation, low quality evidence). 4 For the removal of partially covered esophageal SEMSs that are embedded, ESGE recommends the stent-in-stent technique (strong recommendation, low quality evidence). 5 ESGE recommends that temporary stent placement can be considered for treating esophageal leaks, fistulas, and perforations. The optimal stenting duration remains unclear and should be individualized. (Strong recommendation, low quality evidence.) 6 ESGE recommends placement of a SEMS for the treatment of esophageal variceal bleeding refractory to medical, endoscopic, and/or radiological therapy, or as initial therapy for patients with massive esophageal variceal bleeding (strong recommendation, moderate quality evidence). © Georg Thieme Verlag KG Stuttgart · New York.

  6. The BioStent: novel concept for a viable stent structure.

    PubMed

    Weinandy, Stefan; Rongen, Lisanne; Schreiber, Fabian; Cornelissen, Christian; Flanagan, Thomas Cormac; Mahnken, Andreas; Gries, Thomas; Schmitz-Rode, Thomas; Jockenhoevel, Stefan

    2012-09-01

    Percutaneous stenting of occluded peripheral vessels is a well-established technique in clinical practice. Unfortunately, the patency rates of small-caliber vessels after stenting remain unsatisfactory. The aim of the BioStent concept is to overcome in-stent restenosis by excluding the diseased vessel segment entirely from the blood stream, in addition to providing an intact endothelial cell layer. The concept combines the principles of vascular tissue engineering with a self-expanding stent: casting of the stent within a cellularized fibrin gel structure, followed by bioreactor conditioning, allows complete integration of the stent within engineered tissue. Small-caliber BioStents (Ø=6 mm; n=4) were produced by casting a nitinol stent within a thin fibrin/vascular smooth muscle cell (vSMC) mixture, followed by luminal endothelial cell seeding, and conditioning of the BioStent within a bioreactor system. The potential remodeling of the fibrin component into tissue was analyzed using routine histological methods. Scanning electron microscopy was used to assess the luminal endothelial cell coverage following the conditioning phase and crimping of the stent. The BioStent was shown to be noncytotoxic, with no significant effect on cell proliferation. Gross and microscopic analysis revealed complete integration of the nitinol component within a viable tissue structure. Hematoxylin and eosin staining revealed a homogenous distribution of vSMCs throughout the thickness of the BioStent, while a smooth, confluent luminal endothelial cell lining was evident and not significantly affected by the crimping/release process. The BioStent concept is a platform technology offering a novel opportunity to generate a viable, self-expanding stent structure with a functional endothelial cell lining. This platform technology can be transferred to different applications depending on the luminal cell lining required.

  7. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com; Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr; Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payermore » perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.« less

  8. Optical stent inspection of surface texture and coating thickness

    NASA Astrophysics Data System (ADS)

    Bermudez, Carlos; Laguarta, Ferran; Cadevall, Cristina; Matilla, Aitor; Ibañez, Sergi; Artigas, Roger

    2017-02-01

    Stent quality control is a critical process. Coronary stents have to be inspected 100% so no defective stent is implanted into a human body. We have developed a high numerical aperture optical stent inspection system able to acquire both 2D and 3D images. Combining a rotational stage, an area camera with line-scan capability and a triple illumination arrangement, unrolled sections of the outer, inner, and sidewalls surfaces are obtained with high resolution. During stent inspection, surface roughness and coating thickness uniformity is of high interest. Due to the non-planar shape of the surface of the stents, the thickness values of the coating need to be corrected with the 3D surface local slopes. A theoretical model and a simulation are proposed, and a measurement with white light interferometry is shown. Confocal and spectroscopic reflectometry showed to be limited in this application due to stent surface roughness. Due to the high numerical aperture of the optical system, only certain parts of the stent are in focus, which is a problem for defect detection, specifically on the sidewalls. In order to obtain fully focused 2D images, an extended depth of field algorithm has been implemented. A comparison between pixel variance and Laplacian filtering is shown. To recover the stack image, two different methods are proposed: maximum projection and weighted intensity. Finally, we also discuss the implementation of the processing algorithms in both the CPU and GPU, targeting real-time 2-Million pixel image acquisition at 50 frames per second.

  9. A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India.

    PubMed

    Chandra, Praveen; Kumar, Tarun

    2014-01-01

    A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  10. [A Case of Peritoneal Metastasis in Which Colostomy Was Useful for Restenosis after Stenting].

    PubMed

    Tagawa, Hiroko; Yoshimatsu, Kazuhiko; Yokomizo, Hajime; Yano, Yuki; Nakayama, Mao; Okayama, Sachiyo; Satake, Masaya; Sakuma, Akiko; Matsumoto, Atsuo; Fujimoto, Takashi; Shiozawa, Shunichi; Shimakawa, Takeshi; Katsube, Takao; Kato, Hiroyuki; Naritaka, Yoshihiko

    2015-11-01

    We report a case of restenosis after performing stenting twice for ileus caused by peritoneal dissemination that occurred after surgery for sigmoid colon cancer, in which colostomy was performed to improve the patient's QOL. The patient was a 58-year-old woman who underwent sigmoidectomy for sigmoid colon cancer. She presented with a peritoneal recurrence 3 times, and the third surgery was a non-curative resection. Chemotherapy was administered but was discontinued because of severe adverse events, and the patient was followed up with the best supportive care. An anastomotic stricture occurred 4 years after the initial surgery, and despite performing stenting twice, stenosis occurred 3 times within a few months. The third stenosis occurred shortly after the second episode, and colostomy was therefore performed. The patient died from cancer 4 months after colostomy without having another episode of stenosis. Although stenting is effective for patients with malignant colon stenosis, colostomy appears to be more effective for repeated post-stenting stenosis, when the patient is in an eligible general condition.

  11. Stent placement for palliation of cor triatriatum dexter in a dog with suspected patent foramen ovale.

    PubMed

    Barncord, Kristin; Stauthammer, Christopher; Moen, Sean L; Hanson, Melissa; Gruenstein, Daniel H

    2016-03-01

    An 11 month old spayed, female dog presented with exercise intolerance and cyanosis upon exertion. Echocardiography revealed an imperforate cor triatriatum dexter with mild tricuspid valve dysplasia, an underfilled right ventricle and significant right to left shunting across a presumptive patent foramen ovale. Balloon dilation of the abnormal atrial membrane was initially successful in creating a communication between the right atrial chambers, but stenosis of the original perforation and persistent clinical signs prompted a second intervention. A balloon expandable biliary stent was placed across the abnormal partition, improving caudal venous return to the right ventricle and reducing the right to left shunt. Three months after stent placement, resting oxygen saturation had normalized. Six months after stent placement, exercise tolerance had improved and exertional cyanosis had resolved. Long term follow up will be necessary to assess for remodeling of the right ventricle with improved venous return. Stent placement can be considered as a palliative treatment option for cor triatriatum dexter, especially for stenosis post-balloon dilation. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Analysis of trends and prospects regarding stents for human blood vessels.

    PubMed

    Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo

    2018-01-01

    The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used to supplement and complement the primary research. Interviews were conducted with physicians and surgeons from the key hospitals and senior sale/marketing managers from stent product suppliers in South Korea. The global stent market is estimated at US $ 7.98 billion in 2016 and is expected to grow at a Compound Annual Growth Rate (CAGR) of 3.8% over the next 5 years. As of 2016, the global market for vascular stents is estimated at $ 7.22 billion, with coronary artery stents accounting for 67.3% of the vascular stent market. Among the coronary artery stents, BRS is notably expected to grow at an annual average rate of 8.8% by 2020, but the global adoption rate of BRS remains low at present. In the Korean market, stents for blood vessels account for most of the market, and the market size of stents for blood vessels in Korea was estimated to be 145 billion won as of 2016. In comparison to the sales growth rate of other medical devices, the future stent technology market is judged to be higher in growth potential.

  13. Lean manufacturing and Toyota Production System terminology applied to the procurement of vascular stents in interventional radiology.

    PubMed

    de Bucourt, Maximilian; Busse, Reinhard; Güttler, Felix; Wintzer, Christian; Collettini, Federico; Kloeters, Christian; Hamm, Bernd; Teichgräber, Ulf K

    2011-08-01

    OBJECTIVES: To apply the economic terminology of lean manufacturing and the Toyota Production System to the procurement of vascular stents in interventional radiology. METHODS: The economic- and process-driven terminology of lean manufacturing and the Toyota Production System is first presented, including information and product flow as well as value stream mapping (VSM), and then applied to an interdisciplinary setting of physicians, nurses and technicians from different medical departments to identify wastes in the process of endovascular stent procurement in interventional radiology. RESULTS: Using the so-called seven wastes approach of the Toyota Production System (waste of overproducing, waiting, transport, processing, inventory, motion and waste of defects and spoilage) as well as further waste characteristics (gross waste, process and method waste, and micro waste), wastes in the process of endovascular stent procurement in interventional radiology were identified and eliminated to create an overall smoother process from the procurement as well as from the medical perspective. CONCLUSION: Economic terminology of lean manufacturing and the Toyota Production System, especially VSM, can be used to visualise and better understand processes in the procurement of vascular stents in interventional radiology from an economic point of view.

  14. Bacteriology of urinary tract infection associated with indwelling J ureteral stents.

    PubMed

    Kehinde, Elijah O; Rotimi, Vincent O; Al-Hunayan, Adel; Abdul-Halim, Hamdy; Boland, Fareeda; Al-Awadi, Khaleel A

    2004-11-01

    To investigate the microorganisms responsible for urinary tract infection (UTI) and stent colonization in patients with indwelling J ureteral stents and to compare the antimicrobial susceptibility pattern of the isolates from urine and J stents in order to establish the etiologic agents of bacteriuria and colonized stents in such patients and provide baseline data on an antibiotic policy for the urology unit. Midstream urine from 250 patients requiring J stent insertion was investigated microbiologically prior to stent insertion and on the day of stent removal. After stent removal, 3 to 5 cm of the tip located in the bladder was also sent for culture. Patients' bio-data and underlying diseases were documented. Those with no known systemic diseases ("normal patients") were also studied as controls. Of the 250 patients studied, 152 (61%) were normal, while 27 (11%), 53 (21%), and 18 (7%) had diabetes mellitus (DM), chronic renal failure (CRF), and diabetic nephropathy (DN), respectively. The mean duration of stent retention was 27 days. All microbial isolates were tested for their susceptibility to a panel of 10 antibiotics. Twelve patients (5%) before stent insertion and 42 patients (17%; P < 0.001) on the day of stent removal had positive urine cultures. One hundred four stents (42%) were culture positive. Of the 104 patients with positive stent cultures, in 62 patients (60%), urine culture was sterile. The commonest isolates were Escherichia coli, Enterococcus spp., Staphylococcus spp., Pseudomonas, and Candida spp. On the day of stent removal, urine culture was positive in 28% of the normal patients compared with 57% (P = 0.11), 78% (P < 0.001), and 62% (P < 0.001) of patients with CRF, DM, and DN, respectively. Stent isolates were more resistant to antibiotics than the organism isolated before stent insertion. An indwelling J ureteral stent carries a significant risk of bacteriuria and stent colonization. The sensitivity of urine culture to stent colonization is low, and therefore, a negative culture does not rule out a colonized stent. Bacteria cultured from urine after stent insertion and from the stents are more resistant to antibiotics than are those cultured from urine before stent insertion. Norfloxacin or ciprofloxacin is recommended as prophylaxis prior to stent insertion, and an aminoglycoside can be added to treat symptomatic patients with severe infections.

  15. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.

    PubMed

    Muramatsu, Takashi; Onuma, Yoshinobu; van Geuns, Robert-Jan; Chevalier, Bernard; Patel, Tejas M; Seth, Ashok; Diletti, Roberto; García-García, Hector M; Dorange, Cécile C; Veldhof, Susan; Cheong, Wai-Fung; Ozaki, Yukio; Whitbourn, Robert; Bartorelli, Antonio; Stone, Gregg W; Abizaid, Alexandre; Serruys, Patrick W

    2014-05-01

    The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). Clinical outcomes of diabetic patients after BVS implantation have been unreported. This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and diabetic patients treated with EES at 1-year follow-up. (ABSORB Clinical Investigation, Cohort B; NCT00856856; ABSORB EXTEND Clinical Investigation; NCT01023789; Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT FIRST]; NCT00180453; A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT II]; NCT00180310; Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System [EECSS] [SPIRIT III]; NCT00180479; Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT IV Clinical Trial]; NCT00307047). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. 78 FR 53773 - Select Updates for Non-Clinical Engineering Tests and Recommended Labeling for Intravascular...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-30

    ...] Select Updates for Non-Clinical Engineering Tests and Recommended Labeling for Intravascular Stents and... Engineering Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems.'' FDA has developed this guidance to inform the coronary and peripheral stent industry about selected updates to FDA's...

  17. The use of balloon-expandable metallic stents in the treatment of pediatric tracheomalacia and bronchomalacia.

    PubMed

    Furman, R H; Backer, C L; Dunham, M E; Donaldson, J; Mavroudis, C; Holinger, L D

    1999-02-01

    To evaluate the use of balloon-expandable metallic stents in the treatment of children with tracheomalacia and bronchomalacia in whom conventional therapy has failed. Retrospective case series. Tertiary pediatric otolaryngology and cardiothoracic surgery referral center. Six patients were identified as having undergone bronchoscopic placement of metallic balloon-expandable stents between 1994 and 1997. The age at stent placement, prior surgical interventions, and indications for and sites of stent placement were noted. Also, the complications related to stent placement and the current airway status of the patients were reviewed. Twelve balloon-expandable metallic angioplasty stents (Palmaz; Johnson & Johnson Interventional Systems Co, Warren, NJ) were placed bronchoscopically in 6 patients. Six stents were placed in the lower trachea, and 6 were placed in the main bronchi. The stents were balloon expanded under fluoroscopic guidance. Discontinuation of mechanical ventilation. The age at stent placement ranged from 1.5 to 38 months (mean age at placement, 10 months). The indications for stent placement were (1) tracheomalacia or bronchomalacia, (2) pericardial patch or slide tracheoplasty failure, and (3) bronchomalacia caused by tetralogy of Fallot and large pulmonary arteries. The primary complication of stent placement was postoperative granulation tissue formation. One patient required the removal of 2 tracheal stents because of granulation tissue formation. There were 2 deaths in the series, 1 possibly related to stent placement. Four of the 6 patients were weaned from mechanical ventilation, and 3 experienced prolonged relief of airway obstruction. Metallic balloon-expandable stents are effective in relieving lower tracheomalacia and bronchomalacia in select patients. Only patients in whom conventional therapy has failed should be considered for stent placement.

  18. Disruptive technology: new medical advances are troublesome for even the most successful health systems and innovator health companies.

    PubMed

    Michaelis, Lawrence; Vaul, Joanne; Chumer, Kathleen; Faul, Maureen; Sheehan, Lisa; DeCerce, Jack

    2004-01-01

    An independent expert panel conducted a multi-year research/education/advocacy initiative on the impact of the new drug-eluting stent technology. They conclude that this technology represents a "tipping point" in a series of transformative drugs and medical devices, often used in combination, and recommend that healthcare decision makers develop careful, data-based strategies to avoid the disruptiveness of these medical advances.

  19. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction

    PubMed Central

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-01-01

    AIM: To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. METHODS: A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization’s scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. RESULTS: Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CONCLUSION: CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure. PMID:26290640

  20. Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

    PubMed Central

    Kirchner, R Michael; Abbott, J Dawn

    2009-01-01

    Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher®) and paclitaxel-eluting (Taxus®) stents and later approved second-generation everolimus-eluting (Xience V®) and zotarolimus-eluting (Endeavor®) stents. The Xience V stent was approved on the basis of clinical efficacy and safety data from 3 studies in the SPIRIT clinical trial program. Within this trial series, the Xience V was superior to its bare metal stent counterpart, the Vision® stent, and noninferior to the paclitaxel-eluting stent for target vessel failure at 9 months. This review provides a comprehensive assessment of the data derived from both the pre- and post-approval randomized controlled trials and registry studies of Xience V that comprise the SPIRIT clinical trial program including recently published mid-term outcomes. The implications of the results in terms of interventional practice will be discussed. PMID:20057901

  1. Endoscopic management of unresectable malignant gastroduodenal obstruction with a nitinol uncovered metal stent: A prospective Japanese multicenter study

    PubMed Central

    Sasaki, Reina; Sakai, Yuji; Tsuyuguchi, Toshio; Nishikawa, Takao; Fujimoto, Tatsuya; Mikami, Shigeru; Sugiyama, Harutoshi; Yokosuka, Osamu

    2016-01-01

    AIM: To determine the safety and efficacy of endoscopic duodenal stent placement in patients with malignant gastric outlet obstruction. METHODS: This prospective, observational, multicenter study included 39 consecutive patients with malignant gastric outlet obstruction. All patients underwent endoscopic placement of a nitinol, uncovered, self-expandable metal stent. The primary outcome was clinical success at 2 wk after stent placement that was defined as improvement in the Gastric Outlet Obstruction Scoring System score relative to the baseline. RESULTS: Technical success was achieved in all duodenal stent procedures. Procedure-related complications occurred in 4 patients (10.3%) in the form of mild pneumonitis. No other morbidities or mortalities were observed. The clinical success rate was 92.3%. The mean survival period after stent placement was 103 d. The mean period of stent patency was 149 d and the patency remained acceptable for the survival period. Stent dysfunction occurred in 3 patients (7.7%) on account of tumor growth. CONCLUSION: Endoscopic management using duodenal stents for patients with incurable malignant gastric outlet obstruction is safe and improved patients’ quality of life. PMID:27076769

  2. Management of complex benign post-tracheostomy tracheal stenosis with bronchoscopic insertion of silicon tracheal stents, in patients with failed or contraindicated surgical reconstruction of trachea.

    PubMed

    Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N; Zarogoulidis, Paul; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos

    2012-11-01

    Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2(nd) patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are associated with minimal granulation. In benign post-tracheostomy stenosis silicone stenting appeared safe and effective in re-stenosis after surgery and multiple bronchoscopic interventions, and in long stenosis, involving the lower posterior subglottic larynx in the presence on inflammation and poor neurological status.

  3. Surface modification of endovascular stents with rosuvastatin and heparin-loaded biodegradable nanofibers by electrospinning.

    PubMed

    Janjic, Milka; Pappa, Foteini; Karagkiozaki, Varvara; Gitas, Christakis; Ktenidis, Kiriakos; Logothetidis, Stergios

    2017-01-01

    This study describes the development of drug-loaded nanofibrous scaffolds as a nanocoating for endovascular stents for the local and sustained delivery of rosuvastatin (Ros) and heparin (Hep) to injured artery walls after endovascular procedures via the electrospinning process. The proposed hybrid covered stents can promote re-endothelialization; improve endothelial function; reduce inflammatory reaction; inhibit neointimal hyperplasia of the injured artery wall, due to well-known pleiotropic actions of Ros; and prevent adverse events such as in-stent restenosis (ISR) and stent thrombosis (ST), through the antithrombotic action of Hep. Biodegradable nanofibers were prepared by dissolving cellulose acetate (AC) and Ros in N , N -dimethylacetamide (DMAc) and acetone-based solvents. The polymeric solution was electrospun (e-spun) into drug-loaded AC nanofibers onto three different commercially available stents (Co-Cr stent, Ni-Ti stent, and stainless steel stent), resulting in nonwoven matrices of submicron-sized fibers. Accordingly, Hep solution was further used for fibrous coating onto the engineered Ros-loaded stent. The functional encapsulation of Ros and Hep drugs into polymeric scaffolds further underwent physicochemical analysis. Morphological characterization took place via scanning electron microscopy (SEM) and atomic force microscopy (AFM) analyses, while scaffolds' wettability properties were obtained by contact angle (CA) measurements. The morphology of the drug-loaded AC nanofibers was smooth, with an average diameter of 200-800 nm, and after CA measurement, we concluded to the superhydrophobic nature of the engineered scaffolds. In vitro release rates of the pharmaceutical drugs were determined using a high-performance liquid chromatography assay, which showed that after the initial burst, drug release was controlled slowly by the degradation of the polymeric materials. These results imply that AC nanofibers encapsulated with Ros and Hep drugs have great potential in the development of endovascular grafts with anti-thrombogenic properties that can accelerate the re-endothelialization, reduce the neointimal hyperplasia and inflammatory reaction, and improve the endothelial function.

  4. Management of pancreatic collections with a novel endoscopically placed fully covered self-expandable metal stent: a national experience (with videos).

    PubMed

    Chandran, Sujievvan; Efthymiou, Marios; Kaffes, Arthur; Chen, John Wei; Kwan, Vu; Murray, Michael; Williams, David; Nguyen, Nam Quoc; Tam, William; Welch, Christine; Chong, Andre; Gupta, Saurabh; Devereaux, Ben; Tagkalidis, Peter; Parker, Frank; Vaughan, Rhys

    2015-01-01

    Recent medical literature on novel lumen-apposing stents for the treatment of pancreatic fluid collections (PFCs) is limited by small numbers, solo operators, and single-center experience. To evaluate a recently developed lumen-apposing, fully covered self-expandable metal stent (FCSEMS) in the management of PFCs. Retrospective case series. Thirteen tertiary and private health care centers across Australia. Forty-seven patients (median age 51 years) who underwent endoscopic management of PFCs. Insertion of FCSEMS after PFC puncture under EUS guidance. A subgroup of 9 patients underwent direct endoscopic necrosectomy. Technical and clinical success rate, adverse event rate. The technical success rate was 53 of 54 patients (98.1%), and the initial clinical success rate was 36 of 47 (76.6%), which was sustained for more than 6 months in 34 of 36 (94.4%). Early adverse events included 4 cases (7.4%) of stent migration during direct endoscopic necrosectomy, 4 cases (7.4%) of sepsis, 1 case (1.9%) of bleeding, and 1 case (1.9%) of stent migration into the fistula tract. Late adverse events were 6 (11.1%) spontaneous stent migrations, 3 (5.6%) recurrent stent occlusions, 3 (5.6%) tissue ingrowth/overgrowth, and 2 (3.7%) bleeding into PFC. The majority of stents inserted (48 of 54, 88.9%) and removed (31 of 35, 88.6%) in our study were described by the operator as superior to pigtail stents with regard to ease of use. Retrospective study. Although FCSEMSs are technically easier to insert and remove compared with traditional pigtail stents, there are significant limitations to the widespread use of FCSEMSs in the management of PFCs. These include cost, adverse events, and lower-than-expected resolution rates. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Management of complex benign post-tracheostomy tracheal stenosis with bronchoscopic insertion of silicon tracheal stents, in patients with failed or contraindicated surgical reconstruction of trachea

    PubMed Central

    Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N.; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos

    2012-01-01

    Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2nd patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are associated with minimal granulation. In benign post-tracheostomy stenosis silicone stenting appeared safe and effective in re-stenosis after surgery and multiple bronchoscopic interventions, and in long stenosis, involving the lower posterior subglottic larynx in the presence on inflammation and poor neurological status. PMID:23304439

  6. Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    PubMed

    Lu, Huangling; Kalkman, Deborah N; Grundeken, Maik J; Tijssen, Jan G P; Wykrzykowska, Joanna J; de Winter, Robbert J; Koch, Karel T

    2018-02-01

    With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections using the novel Xposition delivery device as compared with the conventional delivery device. A total of 38 patients who were treated with the self-apposing STENTYS stent and with OCT assessment at our center were retrospectively analysed. Twenty patients were treated using the Xposition- and 18 using the conventional delivery device. OCT was performed according to study protocol. Frames with poor quality were excluded. A total of 12(18%) dissections were detected, 7(20%) in the Xposition delivery device group, and 5(15%) in the conventional group (p = 1). Using the Xposition delivery device 4(33%) dissections were found proximally, using the conventional delivery device 3(25%) (p = ns). Mean longitudinal dissection length was 2.07 ± 1.80mm, 8(67%) appeared as flaps, 4(33%) as cavities. Morphometric parameters were comparable in both groups. Detailed OCT assessment of stent edge dissections was possible, which revealed no large differences using the Xposition delivery device as compared with conventional delivery device, however large studies are warranted.

  7. Percutaneous biliary drainage using open cell stents for malignant biliary hilar obstruction.

    PubMed

    Ahn, Sun Jun; Bae, Jae Ik; Han, Tae Sun; Won, Je Hwan; Kim, Ji Dae; Kwack, Kyu-Sung; Lee, Jae Hee; Kim, Young Chul

    2012-01-01

    To evaluate the feasibility, safety and the effectiveness of the complex assembly of open cell nitinol stents for biliary hilar malignancy. During the 10 month period between January and October 2007, 26 consecutive patients with malignant biliary hilar obstruction underwent percutaneous insertion of open cell design nitinol stents. Four types of stent placement methods were used according to the patients' ductal anatomy of the hilum. We evaluated the technical feasibility of stent placement, complications, patient survival, and the duration of stent patency. Bilobar biliary stent placement was conducted in 26 patients with malignant biliary obstruction-T (n = 9), Y (n = 7), crisscross (n = 6) and multiple intersecting types (n = 4). Primary technical success was obtained in 24 of 26 (93%) patients. The crushing of the 1st stent during insertion of the 2nd stent occurred in two cases. Major complications occurred in 2 of 26 patients (7.7%). One case of active bleeding from hepatic segmental artery and one case of sepsis after procedure occurred. Clinical success was achieved in 21 of 24 (87.5%) patients, who were followed for a mean of 141.5 days (range 25-354 days). The mean primary stent patency period was 191.8 days and the mean patient survival period was 299 days. Applying an open cell stent in the biliary system is feasible, and can be effective, especially in multiple intersecting stent insertions in the hepatic hilum.

  8. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    PubMed Central

    2012-01-01

    Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS) and plastic stents (PS).We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS), functional success (FS), early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III). Results The initial stent insertion was successful in 450 (93.8%) patients. TS was achieved in 204 (88.3%) patients treated with PS and in 246 (98.8%) patients palliated with SEMS (p < 0.001). In the intention-to-treat (ITT) analysis, the FS in patients treated with SEMS (97.9%) was significantly higher than in patients treated with PS (84.8%) (p < 0.001). Late complications occurred in 115 (56.4%) patients treated with PS and 60 (24.4%) patients treated with SEMS (p < 0.001). The median duration of stent patency in weeks (w) were as follows: 20 w in patients palliated with PS and 27 w in patients treated with SEMS (p < 0.0001). In Group 2, the median duration of PS patency was 17 w and 18 w for unilateral and bilateral placement, respectively (p = 0.0004); the median duration of SEMS patency was 24 w and 29 w for unilateral and bilateral placement, respectively (p < 0.0001). Multivariate analysis using the Poisson regression showed that SEMS placement (B = 0.48; P < 0.01) and bilateral deployment (B = 0.24; P < 0.01) were the only independent prognostic factors associated with stent patency. Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients. PMID:22873816

  9. Shrinking the Supply Chain for Implantable Coronary Stent Devices.

    PubMed

    Moore, Sean S; O'Sullivan, Kevin J; Verdecchia, Francesco

    2016-02-01

    Stenting treatments for the management of disease in the heart, arterial and venous systems, biliary ducts, urethras, ureters, oesophageal tract and prostate have made enormous technical advances since their introduction into clinical use. The progression from metallic to polymer based bio-absorbable stents, coupled with the advances in additive manufacturing techniques, present a unique opportunity to completely re-envision the design, manufacture, and supply chain of stents. This paper looks at current stenting trends and proposes a future where the stent supply chain is condensed from ~150 days to ~20 min. The Cardiologist therefore has the opportunity to become a designer, manufacturer and user with patients receiving custom stents specific to their unique pathology that will be generated, delivered and deployed in the Cath-lab. The paper will outline this potentially revolutionary development and consider the technical challenges that will need to be overcome in order to achieve these ambitious goals. A high level overview of the generating eluting stents in situ program-GENESIS-is outlined including some early experimental work.

  10. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    PubMed

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as scientific data suggesting a lack of effectiveness, the authors argue that prophylactic intraoperative ureteral stenting should not be used in gynecologic surgery to decrease operative ureteric injury.

  11. 78 FR 35284 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-12

    .... Stent Graft System. P040046, FDA-2013-M-0255 Allergan Natrelle[supreg] 410 February 20, 2013. Highly... Vascular, Resolute Integrity February 22, 2013. Inc. Zotarolimus-Eluting Coronary Stent System. P100030...

  12. New Treatments for Infrapopliteal Disease: Devices, Techniques, and Outcomes So Far

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, Ondina; Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk

    2012-08-15

    The use of endovascular treatment of infrapopliteal disease has increased in popularity in recent years. An improvement in technical success rates due to the availability of newer devices has fuelled an increased interest in the subject. The pathogenesis, indications for treatment, and outcome measures of infrapopliteal disease differ from larger vessel intervention. Diabetes and renal failure are prevalent. Neuropathy and venous disease contribute to the etiology of ulceration. Most interventions are undertaken for critical limb ischemia rather than claudication. Therefore, a range of conservative, pharmacological, and invasive therapies are provided. Conventional percutaneous transluminal angioplasty (PTA) using modern low-profile systems ismore » associated with high technical success rates. However, initial data from recent randomized, controlled trials suggest that drug-eluting stents are consistently achieving improved patency over PTA alone or over bare metal stents. This review summarizes recent advances in the treatment of infrapopliteal disease.« less

  13. Endoscopic ultrasound-guided biliary drainage using a newly designed metal stent with a thin delivery system: a preclinical study in phantom and porcine models.

    PubMed

    Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi

    2017-12-08

    This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.

  14. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    NASA Astrophysics Data System (ADS)

    Winn, Bradley Huegh

    Cardiovascular disease is the leading cause of mortality in The United States and Europe, accounting for approximately half of all deaths. The most common form of cardiovascular disease is atherosclerosis, which is characterized by the formation of fatty atheromatous plaques that can grow to occlude the vessel lumen, thus causing ischemia distal to the occlusion. This is commonly treated using balloon angioplasty, which is usually done in conjunction with the deployment of a stent. Stent deployment helps hold the vessel open following the local injury caused by balloon inflation and prevents elastic recoil and subsequent negative remodeling. Stenting has been shown to significantly reduce restenosis rates from approximately 20-50% without a stent to about 10-30% with stent deployment. However, restenosis still remains the main cause of long-term stent failure. In basic terms, a balloon angioplasty procedure is a forceful displacement of an atherosclerotic lesion serving to widen the vessel lumen to increase blood flow. This procedure causes stretching of the vessel wall, tears in the atherosclerotic plaques, and general damage to the vessel in turn signaling a complex cascade of thrombosis, inflammation, intimal thickening, and vascular remodeling. Stent deployment also further complicates the immunological response by triggering a foreign body response from the implantation of a biomaterial into the body. When performing an angioplasty procedure, particularly in conjunction with stent deployment, a certain degree of vascular injury is inevitable. However, the initial injury can be further complicated by the body's local reaction to the implanted biomaterial, the severity of which can ultimately dictate the degree of restenosis and subsequently affect procedural success. The proliferative response of VSMCs to the various afore mentioned stimuli results in the formation of often copious amounts of neointimal tissue, generally known as intimal hyperplasia. The formation of this new tissue, primarily consisting of VSMCs of the synthetic phenotype and their subsequent extracellular matrix, is the sole causation of in-stent restenosis since the stent serves to prevent elastic recoil and negative remodeling. This doctoral research program is focused on endovascular stent biomaterials science and engineering. Overall, this doctoral project is founded on the hypothesis that smooth muscle cell hyperplasia, as an important causative factor for vascular restenosis following endovascular stent deployment, is triggered by the various effects of stent strut contact on the vessel wall including contact forces and material biocompatibility. In this program, a dynamic in vitro model of a stented blood vessel aimed at evaluating the effect of stent strut material selection, and surface coating on smooth muscle cell response was developed. The in vitro stented artery model was validated through the proliferation of VSMC in contact with stent struts. Additionally, it was demonstrated that, with respect to known biocompatible materials such as Nitinol and 316L stainless steel, DNA synthesis and alpha-actin expression, as indicators of VSMC phenotype, are independent of stent material composition. Furthermore, hydroxyapatite was shown to be a biocompatible stent surface coating with acceptable post-strain integrity. This coating was shown in a feasibility study to be capable of serving as a favorable drug delivery platform able to reliably deliver locally therapeutic doses of bisphosphonates, such as alendronate, to control VSMC proliferation in an in vitro model of a stented blood vessel. This stent coating/drug combination may be effective for reducing restenosis as a result of VSMC hyperplasia in vivo.

  15. Overview of evidence on emergency carotid stenting in patients with acute ischemic stroke due to tandem occlusions: a systematic review and meta-analysis.

    PubMed

    Coelho, Andreia; Lobo, Miguel; Gouveia, Ricardo; Silveira, Diogo; Campos, Jacinta; Augusto, Rita; Coelho, Nuno; Canedo, Alexandra

    2018-01-23

    Endovascular intracranial thrombectomy (IT) has established itself as the standard of care in treating large-vessel anterior circulation acute ischemic stroke (AIS). However, internal carotid artery (ICA) stenosis/occlusion hampers distal access and controversy about simultaneous emergency ICA stenting ensues. The purpose of this review was to evaluate the safety of emergency ICA stenting in combination with IT for AIS with tandem occlusions. To our knowledge this is the first meta-analysis to evaluate emergency ICA stenting in tandem occlusions, combining results from studies with a control group. A systematic review and meta-analysis was conducted according to the recommendations of the Preferred Reporting Items for Systematic reviews and Meta- Analyses (PRISMA) statement. A total of 649 potentially relevant articles were initially selected. After reviewing at title or abstract level, 87 articles were read in full and 23 were included. These studies recruited 1000 patients, 220 submitted to IT with no emergency ICA stenting and 780 to IT and emergency ICA stenting. Successful revascularization (Thrombolysis in cerebral infarction scale - TICI≥2b) was achieved in 48.6-100%. Good outcome (modified Rankin scale - mRS≤2) ranged from 18.2-100%. Symptomatic intracranial haemorrhage (sICH) ranged from 0-45.7% (overall n=168; 17.2%). Mortality at 90 days ranged from 0-45.4% (overall n=114; 11.7%). Time to recanalization was significantly longer in the stenting group with an overall mean difference of 1.76 (95% Confidence Interval: 1.59-1.93). In this meta-analysis time to recanalization was significantly longer in the emergency ICA stenting group. There was no benefit from emergency stenting in parameters such as successful revascularization (TICI≥2b), clinical outcome (mRS≤2) or 90-day mortality. Data on sICH were scarce. Emergency ICA stenting appears to increase time to revascularization and increase the risk of complications with no demonstrated clinical benefit. Furthermore, no prospective, randomized controlled trials demonstrating relative efficacy and safety of concomitant ICA stenting have been published to date. Additional studies must be undertaken to define the role of angioplasty and stenting of the extracranial carotid arteries in the early management of acute stroke in tandem occlusions. Until then, we recommend that ICA stenting concommintant to thrombectomy in acute stroke patients should be avoided.

  16. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium.

    PubMed

    Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T

    2017-04-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. 78 FR 17415 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-21

    ..., FDA-2012-M-1012 Bolton Medical Inc... Relay[supreg] September 21, 2012. Thoracic Stent-Graft with Plus........ Ovation Abdominal October 5, 2012. Stent Graft System. P120007, FDA-2012-M-1066 Gen-Probe, Inc........ Medtronic Vascular... Valiant[supreg] October 26, 2012. Thoracic Stent Graft with the Captivia Delivery...

  18. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less

  19. Long-term outcomes after stenting as a “bridge to surgery” for the management of acute obstruction secondary to colorectal cancer

    PubMed Central

    Suárez, Javier; Jimenez-Pérez, Javier

    2016-01-01

    Obstructive symptoms are present in 8% of cases at the time of initial diagnosis in cases of colorectal cancer. Emergency surgery has been classically considered the treatment of choice in these patients. However, in the majority of studies, emergency colorectal surgery is burdened with higher morbidity and mortality rates than elective surgery, and many patients require temporal colostomy which deteriorates their quality of life and becomes permanent in 10%-40% of cases. The aim of stenting by-pass to surgery is to transform emergency surgery into elective surgery in order to improve surgical results, obtain an accurate tumoral staging and detection of synchronous lesions, stabilization of comorbidities and performance of laparoscopic surgery. Immediate results were more favourable in patients who were stented concerning primary anastomosis, permanent stoma, wound infection and overall morbidity, having the higher surgical risk patients the greater benefit. However, some findings laid out the possible implication of stenting in long-term results of oncologic treatment. Perforation after stenting is related to tumoral recurrence. In studies with perforation rates above 8%, higher recurrences rates in young patients and lower disease free survival have been shown. On the other hand, after stenting the number of removed lymph nodes in the surgical specimen is larger, patients can receive adjuvant chemotherapy earlier and in a greater percentage and the number of patients who can be surgically treated with laparoscopic surgery is larger. Finally, there are no consistent studies able to demonstrate that one strategy is superior to the other in terms of oncologic benefits. At present, it would seem wise to assume a higher initial complication rate in young patients without relevant comorbidities and to accept the risk of local recurrence in old patients (> 70 years) or with high surgical risk (ASA III/IV). PMID:26798441

  20. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.

    PubMed

    Wang, Geng; Sun, Zhongwei; Jin, Quanmin; Xu, Kai; Li, Yi; Wang, Xiaozeng; Ma, Yingyan; Liu, Haiwei; Zhao, Xin; Wang, Bin; Deng, Jie; Guan, Shaoyi; Ge, Meiling; Wang, Xiaoyan; Xu, Bo; Han, Yaling

    2015-03-01

    To evaluate the preliminary safety and efficacy of the EXCEL II stent system. Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation. © 2015 Wiley Periodicals, Inc.

  1. Clinical benefits and oncologic equivalence of self-expandable metallic stent insertion for right-sided malignant colonic obstruction.

    PubMed

    Ji, Woong Bae; Kwak, Jung Myun; Kang, Dong Woo; Kwak, Han Deok; Um, Jun Won; Lee, Sun-Il; Min, Byung-Wook; Sung, Nak Song; Kim, Jin; Kim, Seon Hahn

    2017-01-01

    The efficacy of stenting for right-sided malignant colonic obstruction is unknown. This study aimed to evaluate the safety, feasibility, and clinical benefits of self-expandable metallic stent insertion for right-sided malignant colonic obstruction. Clinical data from patients who underwent right hemicolectomy for right colon cancer from January 2006 to July 2014 at three Korea University hospitals were retrospectively reviewed. A total of 39 patients who developed malignant obstruction in the right-sided colon were identified, and their data were analyzed. Stent insertion was attempted in 16 patients, and initial technical success was achieved in 14 patients (87.5 %). No stent-related immediate complications were reported. Complete relief from obstruction was achieved in all 14 patients. Twenty-five patients, including two patients who failed stenting, underwent emergency surgery. In the stent group, 93 % (13/14) of patients underwent elective laparoscopic surgery, and only one surgery was converted to an open procedure. All patients in the emergency group underwent emergency surgery within 24 h of admission. In the emergency group, only 12 % (3/25) of patients underwent laparoscopic surgery, with one surgery converted to an open procedure. All patients in both groups underwent either laparoscopy-assisted or open right/extended right hemicolectomy with primary anastomoses as the first operation. The operative times, retrieved lymph nodes, and pathologic stage did not differ between the two groups. Postoperative hospital stay (9.4 ± 3.4 days in the stent group vs. 12.4 ± 5.9 in the emergency group, p = 0.089) and time to resume oral food intake (3.2 ± 2.1 days in the stent group vs. 5.7 ± 3.4 in the emergency group, p = 0.019) were shorter in the stent group. And there were no significant differences in disease-free survival and overall survival between the two groups. Stent insertion appears to be safe and feasible in patients with right-sided colonic malignant obstruction. It facilitates minimally invasive surgery and may result in better short-term surgical outcomes.

  2. A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.

    PubMed

    Takahara, Naminatsu; Isayama, Hiroyuki; Nakai, Yousuke; Yoshida, Shuntaro; Saito, Tomotaka; Mizuno, Suguru; Yagioka, Hiroshi; Kogure, Hirofumi; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Tada, Minoru; Koike, Kazuhiko

    2017-07-15

    Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.

  3. 75 FR 38532 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... LLIAC March 5, FDA-2010-M-0135 Scientific PREMOUNTED STENT SYSTEM 2010 Corp. P090006 Medtronic COMPLETE SE VASCULAR March 17, FDA-2010-M-0158 Vascular STENT SYSTEM 2010 II. Electronic Access Persons with...

  4. Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.

    PubMed

    Win, Htut K; Caldera, Angel E; Maresh, Kelly; Lopez, John; Rihal, Charanjit S; Parikh, Manish A; Granada, Juan F; Marulkar, Sachin; Nassif, Deborah; Cohen, David J; Kleiman, Neal S

    2007-05-09

    Clinical trials that have excluded patients at high risk for cardiac events have led to commercial labeling approval of drug-eluting stents; nevertheless, such high-risk patients commonly undergo stent placement in clinical practice. The degree to which they experience cardiac events at a higher rate than non-high-risk patients is unclear. To assess the rates of major adverse cardiac events during the index admission and 1 year after the implantation of drug-eluting stents in patients with high-risk angiographic and clinical features. From July 2004 to September 2005, consecutive patients who underwent attempted stent placement at 42 different hospitals throughout the United States were enrolled in a prospective multicenter registry. We analyzed outcomes of 3323 patients who received at least 1 drug-eluting stent for a reason other than acute ST-segment elevation myocardial infarction. The study population was divided into 2 groups based on presence of at least 1 of 9 off-label characteristics based on the current US Food and Drug Administration-approved indications for sirolimus- and paclitaxel-eluting stents. The composite clinical outcomes of death, myocardial infarction, or target vessel revascularization during the index admission and death, myocardial infarction, or target lesion revascularization at 1 year were evaluated. Of the 3323 patients, 1817 (54.7%) had at least 1 off-label characteristic. During the index hospitalization, the composite clinical outcome occurred in 198 (10.9%) of patients in the off-label group and 76 (5.0%) of patients in the on-label group (adjusted odds ratio, 2.32; 95% confidence interval [CI], 1.75-3.07; P<.001). At 1 year, the composite clinical outcome occurred more often in the off-label group compared with the on-label group; 309 (17.5%) vs 131 (8.9%) (adjusted hazard ratio [HR], 2.16; 95% CI, 1.74-2.67; P<.001). Stent thrombosis also occurred more frequently among patients in the off-label group during the initial hospitalization (8 [0.4%] vs 0) and at 1 year: 29 (1.6%) vs 13 (0.9%), adjusted HR, 2.29 (95% CI, 1.02-5.16; P = .05). Compared with on-label use, off-label use of drug-eluting stents is associated with a higher rate of adverse outcomes during the index admission and at 1 year. Stent thrombosis occurred predominantly in patients who underwent off-label drug-eluting stent implantation. Clinicians should be cautious about extrapolating the benefits of drug-eluting stents over bare-metal stents observed in randomized clinical trials to higher-risk clinical settings that have not been assessed.

  5. Interventional radiology and the use of metal stents in nonvascular clinical practice: a systematic overview.

    PubMed

    Pron, G; Common, A; Simons, M; Ho, C S

    1999-05-01

    The intent of this systematic overview was to describe the clinical role of metal stents in nonvascular health care interventions and the level of evidence supporting their use. Structured searches of Medline were conducted and limited to original peer-reviewed articles published in English. Clinical practice involving metal stents was reported in more than 109 clinical series involving 4,753 patients. Stents were placed mainly for palliation of malignant biliary, esophageal, and airway obstruction in patients who were untreatable or had surgically unresectable lesions. Assessment of these interventions has so far centered on safety and technical success. Efficacy, quality of life, and costing factors were not routinely reported. Randomized trial evidence was available but limited; six randomized trials involving metal stents have been reported. Three trials involved biliary malignant obstruction, and all three reported metal stent (132 patients) palliation to be superior to plastic stent palliation (136 patients) based on longer patency and lower reintervention costs. Safety and complication differences between stents, however, were inconsistent across trials. In three trials involving esophageal malignant obstruction, metal stent (82 patients) palliation was reported to be superior to plastic stent (41 patients), based on lower complication and reintervention rates, and superior to laser therapy (18 patients), based on better dysphagia relief. Use of metal stents has been reported for obstructed ducts and passageways of most body systems. There is, however, limited controlled trial evidence confirming the advantages of their use over plastic stents or other forms of treatment.

  6. Stent design favorably influences the vascular response in normal porcine coronary arteries.

    PubMed

    Carter, A J; Scott, D; Rahdert, D; Bailey, L; De Vries J; Ayerdi, K; Turnlund, T; Jones, R; Virmani, R; Fischell, T A

    1999-03-01

    The purpose of this study was to compare the arterial response following implantation of a stainless-steel, balloon-expandable, tubular slotted stent with that of a novel computer-designed, multi-cellular stent in normal porcine coronary arteries. Intracoronary stent placement has evolved into the primary strategy for percutaneous revascularization of symptomatic coronary arterial lesions. Presently there is intense interest in developing new stent designs to improve stent delivery and biocompatability. Computer-assisted design was utilized to develop a balloon-expandable stent with symmetric expansion properties, uniform arterial wall coverage, longitudinal flexibility and radial strength. Quantitative coronary angiography and histological assessment of the stented arteries was used to evaluate the acute and chronic vascular responses to a stainless-steel, balloon-expandable, tubular slotted stent as compared to the computer-designed BX stent in the normolipemic swine. Forty stents (24 BX, 16 tubular slotted) were implanted in 19 miniature swine at a mean inflation pressure of 9 atm using identical delivery systems. Eight of the BX and none of the tubular slotted stents were post-dilated with a non-compliant balloon at 12-14 atm. The mean stent-to-artery ratio was similar for the BX (1.03 +/- 0.06) and tubular slotted (1.04 +/- 0.11; p = 0.59) designs. Protrusion or asymmetric radial flaring of a strut at the stent margin was present in 1 of 23 BX stents (4.3%) and 10 of 15 tubular slotted stents (66.7%; p < 0.0001). The mean arterial injury score was significantly less for the BX stent (0.2 +/- 0.2) as compared with the tubular slotted stents (0.4 +/- 0.4; p = 0.025). At 3 days, thrombus area was similar for the BX and tubular slotted designs (0.42 +/- 0.16 mm2 versus 0.44 +/- 0.18 mm2, respectively; p = 0.88). The mean neointimal area was significantly less for the BX at 2 months (1.09 +/- 0.25 mm2 versus 2.93 +/- 2.26 mm2 in the tubular slotted stent) and at 6 months (1.10 +/- 0.26 mm2 versus 2.07 +/- 0.65 mm2 in the tubular slotted stent; p = 0.01), resulting in approximately 50% less in-stent stenosis. The arterial response to a balloon-expandable stent can be favorably influenced by computer-assisted modification of design in an experimental model. Further study is warranted to determine the impact of stent design upon clinical in-stent restenosis.

  7. Auxetic coronary stent endoprosthesis: fabrication and structural analysis.

    PubMed

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar; Mir, Mariam; Minhas, Muhammad Asim; Shahid, Wakeel

    2015-07-04

    Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. The auxetic design was obtained via laser cutting, and surface treatment was performed with acid pickling and electropolishing, followed by an annealing process. In vitro mechanical analysis was performed to analyze the mechanical performance of the auxetic coronary stent. Scanning electronic microscopy (SEM) was used to determine the effects of fabrication processes on the topography of the auxetic stent. The elastic recoil (3.3%) of the in vitro mechanical analysis showed that the auxetic stent design effectively maintained the luminal patency of the coronary artery. Also, the auxetic coronary stent showed no foreshortening, therefore it avoids the problem of stent migration, by expanding in both the radial and longitudinal directions. By virtue of its synclastic behavior, the auxetic stent bulges outward when it is radially expanded through an inflated balloon.

  8. Experimental Study of Poly-l-Lactic Acid Biodegradable Stents in Normal Canine Bile Ducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Kiyosei, E-mail: yamakiyo@zg7.so-net.ne.jp; Yoshioka, Tetsuya; Furuichi, Kinya

    Purpose: This study was designed to clarify the advantages of biodegradable stents in terms of mucosal reaction and biodegradation after placement. We designed a biodegradable stent and assessed stent degradation and changes in the normal bile ducts of dogs. Methods: The biodegradable stent is a balloon-expandable Z stent consisting of poly-l-lactic acid (PLLA) with a diameter of 6 mm and a length of 15 mm. We assessed four groups of three beagle dogs each at 1, 3, 6, and 9 months of follow-up. After evaluating stent migration by radiography and stent and bile duct patency by cholangiography, the dogs weremore » sacrificed to remove the bile duct together with the stent. The bile duct lumen was examined macroscopically and histologically, and the stent degradation was examined macroscopically and by scanning electron microscopy (SEM). Results: Bile duct obstruction was absent and none of the stents migrated. Macroscopic evaluation showed moderate endothelial proliferation in the bile ducts at the implant sites at 3 and 6 months and a slight change at 9 months. Slight mononuclear cell infiltration was histologically identified at all time points and epithelial hyperplasia that was moderate at 3 months was reduced to slight at 6 and 9 months. Stent degradation was macroscopically evident in all animals at 9 months and was proven by SEM in two dogs at 6 months and in all of them at 9 months. Conclusions: Our results suggest that PLLA bioabsorbable stents seems to be useful for implantation in the biliary system with further investigation.« less

  9. Stent-based nitric oxide delivery reducing neointimal proliferation in a porcine carotid overstretch injury model.

    PubMed

    Hou, Dongming; Narciso, Hugh; Kamdar, Kirti; Zhang, Ping; Barclay, Bruce; March, Keith L

    2005-01-01

    The effects of nitric acid (NO) on vessel response to injury include the inhibition of platelet adhesion, platelet aggregation, leukocyte adhesion and smooth muscle cell proliferation. Releasing NO from a stent might reduce the clinical problem of restenosis. The present study was designed to examine whether an NO-eluting covered stent can prevent neointimal formation in a porcine carotid overstretch injury model. The interior of a self-expanding polytetrafluoroethylene (ePTFE)-covered aSpire stent was coated with silicone, which contained 23.6 microg or 54.5 microg sodium nitroprusside (SNP, NO-releasing compound). The stent was implanted into carotid artery. Six pigs were implanted with stents, one high-dose SNP and one uncoated control, following balloon overstretch injury of the carotid artery with a balloon-to-artery ratio of 1.3:1. No local or systemic toxicity was evidenced in the six pigs after carotid artery implantation with either low- or high-dose stents within a week. At day 28, the mean intimal thickness was 0.12 +/- 0.05 mm for NO-eluting stents and 0.43 +/- 0.09 mm for uncoated stents (p = 0.008). The mean neointimal area was reduced from 2.40 +/- 0.39 mm2 for control stents to 0.49 +/- 0.16 mm2 for NO-eluting stents (p < 0.0001), which resulted in a 24% reduction of angiographic vessel narrowing. The NO-eluting ePTFE-covered stent is feasible and effectively reduces in-stent neointimal hyperplasia at 28 days in a porcine carotid overstretch model.

  10. Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis.

    PubMed

    Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K

    2016-06-01

    Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. 225 intracranial aneurysms treated with the Low-profile Visualized Intraluminal Support (LVIS) stent: a single-center retrospective study.

    PubMed

    Su, Wei; Zhang, Yisen; Chen, Junfan; Liu, Jian; Rajah, Gary; Yang, Xinjian

    2018-04-23

    Background For the treatment of intracranial aneurysms, the low-profile visualized intraluminal support (LVIS) stent is a new generation of highly visible-braided stent that was recently introduced in China. Here, we report our single-center retrospective experience of safety and efficacy utilizing LVIS for stent-assisted coiling of intracranial aneurysms. Methods We included 218 patients with intracranial aneurysms consecutively treated with LVIS SR stents at our center in this study. Postoperative and follow-up embolization scores, procedural complications, clinical and angiographic findings at mid-term follow-up, as well as recurrence rate, preoperative and follow-up mRS scores were analyzed. Results Two hundred and eighteen patients with two hundred and twenty five intracranial aneurysms were enrolled. The locations and distribution were ICA (125, 55.6%), PcomA (47, 20.9%), VA (38, 16.8%), and BA (15, 6.7%). Two hundred and eighteen aneurysms were treated with the stent-assisted coiling and seven patients with LVIS stents alone. Angiographic follow-up was available for 115 (51.1%) aneurysms, 8 (7.0%) of which had recurrences including 7 (6.5%) unruptured aneurysms and 1(14.3%) ruptured aneurysm. The procedural complication rate was 2.75% in total, including distal hemorrhage (1, 0.45%; SAH), ischemic events (5, 2.3%). Conclusions Our single-center retrospective experience is one of the larger studies to date assessing the LVIS device. Compared with many laser-cut stent studies, the LVIS device had a higher aneurysm complete occlusion rate at follow-up coupled with low complication rates. However, this study was our initial experience with LVIS, larger patient numbers, and longer follow-up will be needed to fully assess the long-term efficacy of LVIS in treating intracranial aneurysms.

  12. Stent-mediated gene and drug delivery for cardiovascular disease and cancer: A brief insight.

    PubMed

    Krishnagopal, Akshaya; Reddy, Aakash; Sen, Dwaipayan

    2017-05-01

    This review concisely recapitulates the different existing modes of stent-mediated gene/drug delivery, their considerable advancement in clinical trials and a rationale for other merging new technologies such as nanotechnology and microRNA-based therapeutics, in addition to addressing the limitations in each of these perpetual stent platforms. Over the past decade, stent-mediated gene/drug delivery has materialized as a hopeful alternative for cardiovascular disease and cancer in contrast to routine conventional treatment modalities. Regardless of the phenomenal recent developments achieved by coronary interventions and cancer therapies that employ gene and drug-eluting stents, practical hurdles still remain a challenge. The present review highlights the limitations that each of the existing stent-based gene/drug delivery system encompasses and therefore provides a vision for the future with respect to discovering an ideal stent therapeutic platform that would circumvent all the practical hurdles witnessed with the existing technology. Further study of the improvisation of next-generation drug-eluting stents has helped to overcome the issue of restenosis to some extent. However, current stent formulations fall short of the anticipated clinically meaningful outcomes and there is an explicit need for more randomized trials aiming to further evaluate stent platforms in favour of enhanced safety and clinical value. Gene-eluting stents may hold promise in contributing new ideas for stent-based prevention of in-stent restenosis through genetic interventions by capitalizing on a wide variety of molecular targets. Therefore, the central consideration directs us toward finding an ideal stent therapeutic platform that would tackle all of the gaps in the existing technology. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Tracheobronchial Polyflex stents for the management of benign refractory hypopharyngeal strictures.

    PubMed

    Silva, Rui Almeida; Mesquita, Nuno; Nunes, Pedro Pimentel; Cardoso, Elisabete; Pinto, Ricardo Marcos; Dias, Luís Moreira

    2012-02-14

    To describe a modified technique for placement of a tracheobronchial self-expanding plastic stent (SEPS) in patients with benign refractory hypopharyngeal strictures in order to improve dysphagia and allow stricture remodeling. A case series of four consecutive patients with complex hypopharyngeal strictures after combined therapy for laryngeal cancer, previously submitted to multiple sessions of dilation without lasting improvement, is presented. All patients underwent placement of a small diameter and unflared tracheobronchial SEPS. Main outcome measurements were improvement of dysphagia and avoiding of repeated dilation. The modified introducer system allowed an easy and technically successful deployment of the tracheobronchial Polyflex stent through the stricture. All four patients developed complications related to stent placement. Two patients had stent migration (one proximal and one distal), two patients developed phanryngocutaneous fistulas and all patients with stents in situ for more than 8 wk had hyperplastic tissue growth at the upper end of the stent. Stricture recurrence was observed at 4 wk follow-up after stent removal in all patients. Although technically feasible, placement of a tracheobronchial SEPS is associated with a high risk of complications. Small diameter stents must be kept in place for longer than 3 mo to allow adequate time for stricture remodeling.

  14. Fiber laser micromachining of magnesium alloy tubes for biocompatible and biodegradable cardiovascular stents

    NASA Astrophysics Data System (ADS)

    Demir, Ali Gökhan; Previtali, Barbara; Colombo, Daniele; Ge, Qiang; Vedani, Maurizio; Petrini, Lorenza; Wu, Wei; Biffi, Carlo Alberto

    2012-02-01

    Magnesium alloys constitute an attractive solution for cardiovascular stent applications due to their intrinsic properties of biocompatibility and relatively low corrosion resistance in human-body fluids, which results in as a less intrusive treatment. Laser micromachining is the conventional process used to cut the stent mesh, which plays the key role for the accurate reproduction of the mesh design and the surface quality of the produced stent that are important factors in ensuring the mechanical and corrosion resistance properties of such a kind of devices. Traditionally continuous or pulsed laser systems working in microsecond pulse regime are employed for stent manufacturing. Pulsed fiber lasers on the other hand, are a relatively new solution which could balance productivity and quality aspects with shorter ns pulse durations and pulse energies in the order of mJ. This work reports the study of laser micromachining and of AZ31 magnesium alloy for the manufacturing of cardiovascular stents with a novel mesh design. A pulsed active fiber laser system operating in nanosecond pulse regime was employed for the micromachining. Laser parameters were studied for tubular cutting on a common stent material, AISI 316L tubes with 2 mm in diameter and 0.2 mm in thickness and on AZ31 tubes with 2.5 mm in diameter and 0.2 in thickness. In both cases process parameters conditions were examined for reactive and inert gas cutting solutions and the final stent quality is compared.

  15. Strategies for the Management of SVC Stent Migration into the Right Atrium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, J. D., E-mail: drjeremytaylor@yahoo.co.uk; Lehmann, E. D.; Belli, A.-M.

    Purpose. Stent migration into the right atrium is a potentially fatal complication of stenting in the venous system and is most likely to occur during the treatment of superior vena cava obstruction. Endovascular approaches that can salvage this hazardous situation are described and the keys to successful treatment are highlighted. Materials and Methods. Four different strategies are reviewed: (1) snaring the stent directly, (2) angioplasty balloon-assisted snaring of the stent, (3) guide wire-assisted snaring of the stent, and (4) superior vena cava-to-inferior vena cava bridging stent. Results. These techniques have been employed in the successful management of four cases. Nomore » short- or long-term complications as a result of these maneuvers have been identified. Additional treatment of the underlying disease was possible at the same time in each case. Conclusion. We conclude that prompt management of right atrial stent migration is essential and can be successfully achieved by a variety of 'bale-out' techniques which are within the technical range of most interventional radiologists.« less

  16. Endoscopic Biliary Stenting Versus Percutaneous Transhepatic Biliary Stenting in Advanced Malignant Biliary Obstruction: Cost-effectiveness Analysis.

    PubMed

    Sun, Xin Rong; Tang, Cheng Wu; Lu, Wen Ming; Xu, Yong Qiang; Feng, Wen Ming; Bao, Yin; Zheng, Yin Yuan

    2014-05-01

    This study aims to compare the clinical outcomes and costs between endoscopic biliary stenting (EBS) and percutaneous transhepatic biliary stenting (PTBS). We randomly assigned 112 patients with unresectable malignant biliary obstruction 2006 and 2011 to receive EBS or PTBS with self-expandable metal stent (SEMS) as palliative treatment. PTBS was successfully performed in 55 patients who formed the PTBS group (failed in 2 patients). EBS was successfully performed in 52 patients who formed the EBS group (failed in 3 patients). The effectiveness of biliary drainage, hospital stay, complications, cost, survival time and mortality were compared. Patients in PTBS group had shorter hospital stay and lower initial and overall expense than the BBS group (P < 0.05). There was no significant difference in effectiveness of biliary drainage (P = 0.9357) or survival time between two groups (P = 0.6733). Early complications occurred in PTBS group was significantly lower than in EBS group (3/55 vs 11/52, P = 0.0343). Late complications in the EBS group did not differ significantly from PTBS group (7/55 vs 9/52, P = 0.6922). The survival curves in the two groups showed no significant difference (P = 0.5294). Conclusions: 3.

  17. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

    PubMed Central

    Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A

    2003-01-01

    Objectives: To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Methods: Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). Results: No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Conclusion: Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants. PMID:12748224

  18. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

    PubMed

    Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A

    2003-06-01

    To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants.

  19. Technical and Clinical Results After Percutaneous Angioplasty in Nonmedial Fibromuscular Dysplasia: Outcome After Endovascular Management of Unifocal Renal Artery Stenoses in 30 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrier, Pierre, E-mail: p.barrier@gmail.com; Julien, Auriol; Guillaume, Canevet

    2010-04-15

    Although percutaneous transluminal renal angioplasty (PTRA) is associated with excellent results in medial fibromuscular dysplasia (FMD), the clinical and technical outcome in the less common nonmedial subtype of FMD is not clearly known. Angiographic PTRA results and clinical follow-up were documented, to report technical and clinical results in 30 patients with unifocal, nonmedial dysplastic stenoses. Balloon angioplasty was technically successful in only 65% of the lesions. Additional stenting, performed after PTRA failure in six patients, increased the initial technical success rate to 82%. Stenting was used in another lesion after restenosis, and long-term patency was achieved in only three ofmore » the seven stented lesions. Frequent restenoses and unusual complications were observed during follow-up. Stent fracture occurred in two cases. Overall, long-term clinical and technical successes were sustained in 70 and 76%, respectively. We conclude that nonmedial, unifocal renal artery dysplastic stenoses do not share the excellent prognosis of the medial type and that stenting should be avoided. Therefore, surgery should be considered in lesions remaining unresponsive to balloon dilatation, after a second PTRA attempt.« less

  20. Automatic three-dimensional registration of intravascular optical coherence tomography images

    NASA Astrophysics Data System (ADS)

    Ughi, Giovanni J.; Adriaenssens, Tom; Larsson, Matilda; Dubois, Christophe; Sinnaeve, Peter R.; Coosemans, Mark; Desmet, Walter; D'hooge, Jan

    2012-02-01

    Intravascular optical coherence tomography (IV-OCT) is a catheter-based high-resolution imaging technique able to visualize the inner wall of the coronary arteries and implanted devices in vivo with an axial resolution below 20 μm. IV-OCT is being used in several clinical trials aiming to quantify the vessel response to stent implantation over time. However, stent analysis is currently performed manually and corresponding images taken at different time points are matched through a very labor-intensive and subjective procedure. We present an automated method for the spatial registration of IV-OCT datasets. Stent struts are segmented through consecutive images and three-dimensional models of the stents are created for both datasets to be registered. The two models are initially roughly registered through an automatic initialization procedure and an iterative closest point algorithm is subsequently applied for a more precise registration. To correct for nonuniform rotational distortions (NURDs) and other potential acquisition artifacts, the registration is consecutively refined on a local level. The algorithm was first validated by using an in vitro experimental setup based on a polyvinyl-alcohol gel tubular phantom. Subsequently, an in vivo validation was obtained by exploiting stable vessel landmarks. The mean registration error in vitro was quantified to be 0.14 mm in the longitudinal axis and 7.3-deg mean rotation error. In vivo validation resulted in 0.23 mm in the longitudinal axis and 10.1-deg rotation error. These results indicate that the proposed methodology can be used for automatic registration of in vivo IV-OCT datasets. Such a tool will be indispensable for larger studies on vessel healing pathophysiology and reaction to stent implantation. As such, it will be valuable in testing the performance of new generations of intracoronary devices and new therapeutic drugs.

  1. Simultaneous non-traumatic perforation of the right hepatic duct and gallbladder: an atypical occurrence.

    PubMed

    Garg, Pankaj Kumar; Jain, Bhupendra Kumar; Pandey, Satya Deo; Rathi, Vinita; Puri, Amarendra Singh

    2012-07-01

    Simultaneous non-traumatic perforation of the extrahepatic bile duct and the gallbladder is an uncommon occurrence that has been infrequently reported. We describe a patient with a spontaneous perforation of both the extrahepatic bile duct and the gallbladder. A contrast-enhanced computed tomography (CECT) scan of the abdomen and endoscopic retrograde cholangiopancreatography (ERCP) demonstrated a perforation of the gallbladder and a free leak from the right hepatic duct, respectively. Endoscopic biliary drainage following a sphincterotomy and biliary stent placement led to a dramatic improvement in the patient's general condition. He was subsequently scheduled to undergo an elective cholecystectomy. Repeat ERCP performed at 4 weeks after the initial stenting showed a normal cholangiogram and a distally migrated stent, which was there after removed. However, early stent removal led to re-perforation of hepatic duct and gallbladder. A repeat endoscopic biliary drainage did not help, and the patient developed biliary peritonitis. Surgical exploration revealed a perforation at the fundus of the gallbladder, 400 ml of biliopurulent collection and a frozen Calot's triangle. A subtotal cholecystectomy, gall stone removal, and a thorough peritoneal lavage were undertaken. The patient improved postoperatively. The second biliary stent was removed after 4 months. This case report highlights the role of endoscopic biliary drainage in the management of an extrahepatic bile duct perforation and warns against the early removal of a biliary stent.

  2. Novel temperature-controlled RFA probe for treatment of blocked metal biliary stents in patients with pancreaticobiliary cancers: initial experience.

    PubMed

    Nayar, Manu K; Oppong, Kofi W; Bekkali, Noor L H; Leeds, John S

    2018-05-01

     Radiofrequency ablation (RFA) is used to treat blocked biliary stents in patients with pancreaticobiliary (PB) tumors with varying results. We report our experience with a novel temperature-controlled probe for treatment of blocked metal stents.  Patients with histologically proven PB cancers and a blocked biliary stents were treated using ELRATM electrode (Taewoong Medical) under fluoroscopic guidance. Demographics, clinical outcome, stricture diameter improvements, complications and mortality at 30 days were prospectively recorded.  Nine procedures were performed on seven patients (4 male, 3 female); mean age 65.33 (range 56 - 82 years). Mean stricture diameter prior to RFA was 1.13 mm (SD ± 0.54) and 4.42 mm (SD ± 1.54) following RFA ( P  < 0.0001). Five of seven patients (71 %) required additional stents to ensure optimal drainage. There were no procedure-related complications. Mean follow-up was 193.55 days (range 31 - 540) and three of nine patients (33 %) died due to terminal cancer. These are the first reported data on use of a temperature-controlled RFA catheter in humans to treat blocked metal biliary stents. The device is safe but further randomized trials are required to establish the efficacy and survival benefits of this probe.

  3. Treatment of acquired nasopharyngeal stenosis using a removable silicone stent.

    PubMed

    De Lorenzi, Davide; Bertoncello, Diana; Comastri, Stefano; Bottero, Enrico

    2015-02-01

    The aim of this prospective study was to characterise patient characteristics and the histories of cats with acquired nasopharyngeal stenosis (ANS), and to describe the use of a removable silicone stent for treatment. ANS was diagnosed in 15 cats with clinical signs present for a median of 4 months. Clinical signs included stertor and inspiratory difficulty, nasal discharge, sneezing, dysphagia, regurgitation, vomiting and anorexia. Radiographs revealed a dorsal deviation or deformation of the caudal part of the soft palate in 10 of the cats, a soft tissue density across the cranial nasopharynx in four and no abnormality in one. The stenosis was initially dilated with a Kelly forceps in 10 of the cats and by balloon dilatation in five. A segment of a 24 Fr silicone thoracic catheter was used for the stent in five cats; in the other 10 cats a segment of a 28 Fr catheter was used. The stent was removed after 3 weeks in 12 cats and after 4 weeks in the other three. Endoscopy revealed an adequate nasopharyngeal diameter in all of the cats. At both 3 and 10 months after surgery the response was considered to be satisfactory, with complete resolution of clinical signs in 14 cats and improvement in the remaining cat. The treatment of ANS by stenosis dilatation followed by temporary stenting with a silicone stent is a rapid, safe, economical and effective procedure. © ISFM and AAFP 2014.

  4. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    PubMed Central

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. Conclusion Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment. PMID:24958153

  5. Automated peroperative assessment of stents apposition from OCT pullbacks.

    PubMed

    Dubuisson, Florian; Péry, Emilie; Ouchchane, Lemlih; Combaret, Nicolas; Kauffmann, Claude; Souteyrand, Géraud; Motreff, Pascal; Sarry, Laurent

    2015-04-01

    This study's aim was to control the stents apposition by automatically analyzing endovascular optical coherence tomography (OCT) sequences. Lumen is detected using threshold, morphological and gradient operators to run a Dijkstra algorithm. Wrong detection tagged by the user and caused by bifurcation, struts'presence, thrombotic lesions or dissections can be corrected using a morphing algorithm. Struts are also segmented by computing symmetrical and morphological operators. Euclidian distance between detected struts and wall artery initializes a stent's complete distance map and missing data are interpolated with thin-plate spline functions. Rejection of detected outliers, regularization of parameters by generalized cross-validation and using the one-side cyclic property of the map also optimize accuracy. Several indices computed from the map provide quantitative values of malapposition. Algorithm was run on four in-vivo OCT sequences including different incomplete stent apposition's cases. Comparison with manual expert measurements validates the segmentation׳s accuracy and shows an almost perfect concordance of automated results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Limb-shaking transient ischemic attack masquerading as lumbar radiculopathy from pericallosal artery stenosis treated successfully with intracranial angioplasty and stenting.

    PubMed

    Kalia, Junaid; Wolfe, Thomas; Zaidat, Osama O

    2010-03-01

    The pericallosal artery is rarely associated with intracranial atherosclerotic disease and, until recently, was usually not amenable to endovascular therapy with balloon angioplasty and stenting. We present an elderly patient with postural left leg-shaking episodes secondary to pericallosal artery stenosis, which was treated initially with primary intracranial balloon angioplasty, and subsequently, angioplasty and stenting as a result of recurrent stenosis. Both procedures were preformed without complications, and the patient remained free of symptoms on 6-month follow-up. This case demonstrates unique clinical and neuroendovascular aspects; the isolated postural leg-shaking transient ischemic attacks, initially mistaken for radiculopathy and local joint etiology, were found later to be cerebrovascular ischemic in origin. Moreover, the correlation between the findings of computed tomography perfusion and angiography localized the lesion into the medial frontal lobe and pericallosal artery territory. In addition, the technical aspect provides insight into the current state of neuroendovascular techniques, addressing the difficulty of access into very small and distal intracranial arteries affected by stenosis. Copyright 2010 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    PubMed

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  8. Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images.

    PubMed

    Gabriele, Alex; Marco, Valeria; Gatto, Laura; Paoletti, Giulia; Di Vito, Luca; Castriota, Fausto; Romagnoli, Enrico; Ricciardi, Andrea; Prati, Francesco

    2014-10-01

    The optical coherence tomography (OCT) evaluation of the stent anatomy requires the inspection of sequential cross section (CS). However stent coils cannot be appreciated in the conventional format as the OCT CS simply display stent struts, that are poorly representative of the stent architecture. The aim of the present study was to validate a new software (Carpet View), which unfolds the stented segment, reconstructing it as an open structure and displaying the stent meshwork. 21 patients were studied with frequency domain OCT after the deployment of different stents: seven bio-absorbable scaffolds (Dream), seven bare metal stent (Vision/Multilink8), seven drug eluting stent (Cre8). Conventional CS reconstructions were post-processed with the Carpet View software and analyzed by the same reader twice (intra-observer variability) and by two different readers (inter-observer variability). A small average difference in the number of all struts was obtained with the two methods (conventional vs carpet view reconstruction). Using the carpet view, high intra-observer and inter-observer correlations were found for the number of struts obtained in each coil. The Pearson correlation values were 0.98 (p = 0.0001) and 0.96 (p = 0.0001) respectively. The same number of coils was found when analyses were repeated by the same reader or by a different reader whilst mild differences in the count of stent junctions were reported. The Carpet View can be used to address the stent geometry with high reproducibility. This approach enables the matching of the same stent portion during serial time points and promises to improve the stent assessment.

  9. Adult Patent Ductus Arteriosus: Treatment with a Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munoz, J.J., E-mail: jjmrc@telefonica.net; Urbaneja, A.; Gonzalez, N.

    We present the case of a 63-year-old woman with a short patent ductus arteriosus and aneurysmal pulmonary arteries who was treated by placement of a stent-graft. The technique proved simple and safe. Further research is required to improve the design of stent-grafts and their release system for use of this technique in adult patients with this disorder.

  10. [Tracheobronchial stents: a retrospective analysis of indications, results and in particular complications].

    PubMed

    Tonn, H; Mall, W; Schneider, K-D; Schönhofer, B

    2008-10-01

    Tracheobronchial stents are inserted mainly in cases of malignant and benign airway stenosis. Further indications are esophago-tracheal fistulas, mediastinal fistulas and tracheomalacia. A retrospective analysis was conducted on patients' records, information provided by the general practitioners and relatives of the patients from July 1993 to December 2006 in the Department of Pneumology of the Heidehaus Hospital Hannover (since 6/05 Department of Pneumology and Internal Intensive Care Medicine, Oststadt-Heidehaus Hospital). During the observation period of 13 years a total of 269 stents (177 permanent, 92 temporary) were implanted in 207 patients (1.3 stents per patient). The vast majority of patients (173/207) suffered from an underlying malignancy. About half of the stents were deployed in the trachea. The median length of placement was 116 days in patients with malignancies and 313 days in patients with benign diseases. In about 40 % of the patients notable complications were observed which were directly or indirectly associated with the stents. These findings show the importance of a critical indication for stent implantation. In benign diseases a stent can remain for years inside the tracheobronchial system, if it is well tolerated in the beginning. In malignant diseases the result depends decisively on the stage of the tumour: has the stent been implanted before any other tumour therapy is started or is it an end-stage tumor with no other therapeutic option? In general, complications of stents occur quite frequently. The analysis of stent data leads to some aspects for the prevention of stent-related complications. There should be a strict indication and appropriate choice of stent material. Nevertheless, there remains an ethical dilemma in patients with end-stage disease as to whether to implant a stent or to do nothing against the tumor, because the benefit immediately after stent insertion vanishes with progression of the tumour, so causing extra complications.

  11. Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation.

    PubMed

    Tateshima, Satoshi; Tanishita, Kazuo; Hakata, Yasuhiro; Tanoue, Shin-ya; Viñuela, Fernando

    2009-07-01

    Development of a flexible self-expanding stent system and stent-assisted coiling technique facilitates endovascular treatment of wide-necked brain aneurysms. The hemodynamic effect of self-expandable stent placement across the neck of a brain aneurysm has not been well documented in patient-specific aneurysm models. Three patient-specific silicone aneurysm models based on clinical images were used in this study. Model 1 was constructed from a wide-necked internal carotid artery-ophthalmic artery aneurysm, and Models 2 and 3 were constructed from small wide-necked middle cerebral artery aneurysms. Neuroform stents were placed in the in vitro aneurysm models, and flow structures were compared before and after the stent placements. Flow velocity fields were acquired with particle imaging velocimetry. In Model 1, a clockwise, single-vortex flow pattern was observed in the aneurysm dome before stenting was performed. There were multiple vortices, and a very small fast flow stream was newly formed in the aneurysm dome after stenting. The mean intraaneurysmal flow velocity was reduced by approximately 23-40%. In Model 2, there was a clockwise vortex flow in the aneurysm dome and another small counterclockwise vortex in the tip of the aneurysm dome before stenting. The small vortex area disappeared after stenting, and the mean flow velocity in the aneurysm dome was reduced by 43-64%. In Model 3, a large, counterclockwise, single vortex was seen in the aneurysm dome before stenting. Multiple small vortices appeared in the aneurysm dome after stenting, and the mean flow velocity became slower by 22-51%. The flexible self-expandable stents significantly altered flow velocity and also flow structure in these aneurysms. Overall flow alterations by the stent appeared favorable for the long-term durability of aneurysm embolization. The possibility that the placement of a low-profile self-expandable stent might induce unfavorable flow patterns such as a fast flow stream in the aneurysm dome cannot be excluded.

  12. Three-dimensional reconstruction of coronary stents in vivo based on motion compensated X-ray angiography

    NASA Astrophysics Data System (ADS)

    Schäfer, Dirk; Movassaghi, Babak; Grass, Michael; Schoonenberg, Gert; Florent, Raoul; Wink, Onno; Klein, Andrew J. P.; Chen, James Y.; Garcia, Joel; Messenger, John C.; Carroll, John D.

    2007-03-01

    The complete expansion of the stent during a percutaneous transluminal coronary angioplasty (PTCA) procedure is essential for treatment of a stenotic segment of a coronary artery. Inadequate expansion of the stent is a major predisposing factor to in-stent restenosis and acute thrombosis. Stents are positioned and deployed by fluoroscopic guidance. Although the current generation of stents are made of materials with some degree of radio-opacity to detect their location after deployment, proper stent expansion is hard to asses. In this work, we introduce a new method for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The acquisition protocol consist of a propeller rotation of the X-ray C-arm system of 180°, which ensures sufficient angular coverage for volume reconstruction. The angiographic projections were acquired at 30 frames per second resulting in 180 projections during a 7 second rotational run. The motion of the stent is estimated from the automatically tracked 2D coordinates of the markers on the balloon catheter. This information is used within a motion-compensated reconstruction algorithm. Therefore, projections from different cardiac phases and motion states can be used, resulting in improved signal-to-noise ratio of the stent. Results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current X-ray and intravascular ultrasound techniques.

  13. Complications of silicone stent insertion in patients with expiratory central airway collapse.

    PubMed

    Murgu, Septimiu D; Colt, Henri G

    2007-12-01

    Silicone stent insertion is an alternative treatment for expiratory central airway collapse. This study evaluates the complications (mucus plugging, migration, and granulation tissue) associated with stenting in patients who failed medical therapy and were not surgical candidates. Chart review from 15 consecutive patients treated by silicone stent insertion was done over a 2-year period. Outcomes included (1) changes in functional class, extent and severity of airway collapse (graded from 1 to 4 by using a multidimensional system), procedure- and stent-related complications at 48 hours after stent insertion; (2) frequency of stent-related complications; and (3) frequency of emergent flexible and rigid bronchoscopy (scheduled or emergent) over the follow-up period. Mean functional class and severity and extent of airway collapse significantly improved within 48 hours after treatment (p < 0.05). There were no perioperative deaths. Stent-related complications within 48 hours after stent insertion occurred in 3 patients (1 granulation, 1 migration, and 1 mucus plugging). The mean duration of follow-up for the 12 patients who underwent clinical and bronchoscopic follow-up was 188 days. Twenty-six stent-related complications (12 mucus plugs, 8 migrations, and 6 granulation tissues) were seen in 10 of the 12 patients. Five emergent flexible bronchoscopies and 14 rigid bronchoscopies (6 of which were emergent) were performed during the follow-up period. Silicone stent insertion improves functional status immediately after intervention in patients with expiratory central airway collapse, but is associated with a high rate of stent-related complications and need for repeat bronchoscopic interventions.

  14. The Management of Superior Mesenteric Artery Aneurysm: Experience with 16 Cases in a Single Center.

    PubMed

    Zilun, Li; Henghui, Yin; Yang, Zhao; Mian, Wang; Guangqi, Chang; Shenming, Wang

    2017-07-01

    Superior mesenteric artery aneurysm (SMAA) represents a rare but potentially fatal condition. This study aimed to present the individual management protocol of SMAA in our center and to discuss a potential preliminary treatment algorithm. SMAA patients treated in our center between January 2007 and December 2014 were retrospectively reviewed on January 2015. Sixteen patients with SMAA were identified, including 1 female and 15 males, with a mean age of 48.9 ± 12.9 years. Three patients (3/16, 18.8%) were treated by multiple overlapping bare stents and one (1/16, 6.3%) initially by a single bare stent. Two cases (2/16, 12.5%) were treated by a covered stent implantation, but one of those suffered from SMAA rupture 7 days later, whereas the other had inner-stent thrombosis one month after discharge and died from multiple organ-dysfunction syndrome. Nine patients (9/16, 56.2%) received conservative therapy, one of who received multiple overlapping bare stents implantations for persistent abdominal pain. One patient underwent open surgery. There were 2 major complications, with no death during hospitalization and 1 death during follow-up. SMAA treatment needs to be individually prescribed, based on clinical manifestation, anatomy, and etiology. Multiple overlapping bare stents are safe and effective in selective patients with SMAA, and covered stents should be used with caution to avoid covering proximal branches; open surgery should be reserved for patients with suspected intestinal necrosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. How do we manage post-OLT redundant bile duct?

    PubMed

    Torres, Victor; Martinez, Nicholas; Lee, Gabriel; Almeda, Jose; Gross, Glenn; Patel, Sandeep; Rosenkranz, Laura

    2013-04-28

    To address endoscopic outcomes of post-Orthotopic liver transplantation (OLT) patients diagnosed with a "redundant bile duct" (RBD). Medical records of patients who underwent OLT at the Liver Transplant Center, University Texas Health Science Center at San Antonio Texas were retrospectively analyzed. Patients with suspected biliary tract complications (BTC) underwent endoscopic retrograde cholangiopancreatography (ERCP). All ERCP were performed by experienced biliary endoscopist. RBD was defined as a looped, sigmoid-shaped bile duct on cholangiogram with associated cholestatic liver biomarkers. Patients with biliary T-tube placement, biliary anastomotic strictures, bile leaks, bile-duct stones-sludge and suspected sphincter of oddi dysfunction were excluded. Therapy included single or multiple biliary stents with or without sphincterotomy. The incidence of RBD, the number of ERCP corrective sessions, and the type of endoscopic interventions were recorded. Successful response to endoscopic therapy was defined as resolution of RBD with normalization of associated cholestasis. Laboratory data and pertinent radiographic imaging noted included the pre-ERCP period and a follow up period of 6-12 mo after the last ERCP intervention. One thousand two hundred and eighty-two patient records who received OLT from 1992 through 2011 were reviewed. Two hundred and twenty-four patients underwent ERCP for suspected BTC. RBD was reported in each of the initial cholangiograms. Twenty-one out of 1282 (1.6%) were identified as having RBD. There were 12 men and 9 women, average age of 59.6 years. Primary indication for ERCP was cholestatic pattern of liver associated biomarkers. Nineteen out of 21 patients underwent endoscopic therapy and 2/21 required immediate surgical intervention. In the endoscopically managed group: 65 ERCP procedures were performed with an average of 3.4 per patient and 1.1 stent per session. Fifteen out of 19 (78.9%) patients were successfully managed with biliary stenting. All stents were plastic. Selection of stent size and length were based upon endoscopist preference. Stent size ranged from 7 to 11.5 Fr (average stent size 10 Fr); Stent length ranged from 6 to 15 cm (average length 9 cm). Concurrent biliary sphincterotomy was performed in 10/19 patients. Single ERCP session was sufficient in 6/15 (40.0%) patients, whereas 4/15 (26.7%) patients needed two ERCP sessions and 5/15 (33.3%) patients required more than two (average of 5.4 ERCP procedures). Single biliary stent was sufficient in 5 patients; the remaining patients required an average of 4.9 stents. Four out of 19 (21.1%) patients failed endotherapy (lack of resolution of RBD and recurrent cholestasis in the absence of biliary stent) and required either choledocojejunostomy (2/4) or percutaneous biliary drainage (2/4). Endoscopic complications included: 2/65 (3%) post-ERCP pancreatitis and 2/10 (20%) non-complicated post-sphincterotomy bleeding. No endoscopic related mortality was found. The medical records of the 15 successful endoscopically managed patients were reviewed for a period of one year after removal of all biliary stents. Eleven patients had continued resolution of cholestatic biomarkers (73%). One patient had recurrent hepatitis C, 2 patients suffered septic shock which was not associated with ERCP and 1 patient was transferred care to an outside provider and records were not available for our review. Although surgical biliary reconstruction techniques have improved, RBD represents a post-OLT complication. This entity is rare however, endoscopic management of RBD represents a reasonable initial approach.

  16. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Implantation of a new enteral stent in obstructive colorectal cancer using interventional radiology in patients over 70 years of age.

    PubMed

    Miłek, Tomasz; Ciostek, Piotr

    2015-07-01

    Colorectal cancer is the second leading cause of death due to cancer in Poland. The traditional approach to treat patients included a surgical procedure. Irrespective of the surgical method being used, surgical treatment of malignant colorectal obstruction is associated with prolonged hospitalisation, and the postoperative mortality rate is approximately 5-11%. Due to these problems, more interest has been shown in less invasive methods. Prosthesis implantation is a leading endoscopic method used currently in palliative or preoperative treatment. To compare the results of implantation of traditional stents with the results of implantation of an own stent using minimally invasive methods. Left-sided colon obstruction due to cancer was an indication for transplantation. All patients were aged over 70 years and had serious concomitant diseases. The control group included 50 patients with colorectal cancer who received traditional stents in the period 2009-2011. Our stent covers only the internal length of a tumour. It is not equipped with anti-migration flares. To minimize the risk of migration it has a system of hooks that are responsible for permanent anchorage of the stent within the tumour mass. Implantation technical and clinical success defined as effective decompression of intestinal obstruction was 100% in both groups. There were 2 cases of stent migration in the control group. It is possible to achieve a secure surgical anastomosis after intestinal decompression. Stent implantation is fast and safe thanks to the positioning system that was used. The use of labelled hooks is a secure anti-migration solution.

  18. Fabrication and Optimal Design of Biodegradable Polymeric Stents for Aneurysms Treatments

    PubMed Central

    Han, Xue; Wu, Xia; Kelly, Michael; Chen, Xiongbiao

    2017-01-01

    An aneurysm is a balloon-like bulge in the wall of blood vessels, occurring in major arteries of the heart and brain. Biodegradable polymeric stent-assisted coiling is expected to be the ideal treatment of wide-neck complex aneurysms. This paper presents the development of methods to fabricate and optimally design biodegradable polymeric stents for aneurysms treatment. Firstly, a dispensing-based rapid prototyping (DBRP) system was developed to fabricate coil and zigzag structures of biodegradable polymeric stents. Then, compression testing was carried out to characterize the radial deformation of the stents fabricated with the coil or zigzag structure. The results illustrated the stent with a zigzag structure has a stronger radial stiffness than the one with a coil structure. On this basis, the stent with a zigzag structure was chosen for the development of a finite element model for simulating the real compression tests. The result showed the finite element model of biodegradable polymeric stents is acceptable within a range of radial deformation around 20%. Furthermore, the optimization of the zigzag structure was performed with ANSYS DesignXplorer, and the results indicated that the total deformation could be decreased by 35.7% by optimizing the structure parameters, which would represent a significant advance of the radial stiffness of biodegradable polymeric stents. PMID:28264515

  19. In vivo imaging of superficial femoral artery (SFA) stents for deformation analysis

    NASA Astrophysics Data System (ADS)

    Ganguly, A.; Schneider, A.; Keck, B.; Bennett, N. R.; Fahrig, R.

    2008-03-01

    A high-resolution (198 μm) C-arm CT imaging system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) was optimized for imaging superficial femoral artery (SFA) stents in humans. The SFA is susceptible to the development of atherosclerotic lesions. These are typically treated with angioplasty and stent deployment. However, these stents can have a fracture rate as high as 35%. Fracture is usually accompanied by restenosis and reocclusion. The exact cause of breakage is unknown and is hypothesized to result from deforming forces due to hip and knee flexion. Imaging was performed with the leg placed in both straight and bent positions. Projection images obtained during 20 s scans with ~200° of rotation of the C-arm were back-projected to obtain 3D volumes. Using a semi-automatic software algorithm developed in-house, the stent centerlines were found and ellipses were fitted to the slice normals. Image quality was adequate for calculations in 11/13 subjects. Bending the leg was found to shorten the stents in 10/11 cases with the maximum change being 9% (12 mm in a 133 mm stent), and extend the stent in one case by 1.6%. The maximum eccentricity change was 36% with a bend angle of 72° in a case where the stent extended behind the knee.

  20. Fabrication of hydrophobic structures on coronary stent surface based on direct three-beam laser interference lithography

    NASA Astrophysics Data System (ADS)

    Gao, Long-yue; Zhou, Wei-qi; Wang, Yuan-bo; Wang, Si-qi; Bai, Chong; Li, Shi-ming; Liu, Bin; Wang, Jun-nan; Cui, Cheng-kun; Li, Yong-liang

    2016-05-01

    To solve the problems with coronary stent implantation, coronary artery stent surface was directly modified by three-beam laser interference lithography through imitating the water-repellent surface of lotus leaf, and uniform micro-nano structures with the controllable period were fabricated. The morphological properties and contact angle (CA) of the microstructure were measured by scanning electron microscope (SEM) and CA system. The water repellency of stent was also evaluated by the contact and then separation between the water drop and the stent. The results show that the close-packed concave structure with the period of about 12 μm can be fabricated on the stent surface with special parameters (incident angle of 3°, laser energy density of 2.2 J·cm-2 and exposure time of 80 s) by using the three-beam laser at 1 064 nm, and the structure has good water repellency with CA of 120°.

  1. In vitro biocompatibility of plasma-aided surface-modified 316L stainless steel for intracoronary stents.

    PubMed

    Bayram, Cem; Mizrak, Alpay Koray; Aktürk, Selçuk; Kurşaklioğlu, Hurkan; Iyisoy, Atila; Ifran, Ahmet; Denkbaş, Emir Baki

    2010-10-01

    316L-type stainless steel is a raw material mostly used for manufacturing metallic coronary stents. The purpose of this study was to examine the chemical, wettability, cytotoxic and haemocompatibility properties of 316L stainless steel stents which were modified by plasma polymerization. Six different polymeric compounds, polyethylene glycol, 2-hydroxyethyl methacrylate, ethylenediamine, acrylic acid, hexamethyldisilane and hexamethyldisiloxane, were used in a radio frequency glow discharge plasma polymerization system. As a model antiproliferative drug, mitomycin-C was chosen for covalent coupling onto the stent surface. Modified SS 316L stents were characterized by water contact angle measurements (goniometer) and x-ray photoelectron spectroscopy. C1s binding energies showed a good correlation with the literature. Haemocompatibility tests of coated SS 316L stents showed significant latency (t-test, p < 0.05) with respect to SS 316L and control groups in each test.

  2. Drug eluting balloons for the treatment of coronary artery disease: What can we expect?

    PubMed Central

    Joost, Alexander; Kurowski, Volkhard; Radke, Peter W

    2010-01-01

    Drug-eluting balloons (DEBs) represent an enhancement of the therapeutic repertoire for the interventional cardiologist. The therapeutic concept of DEBs is promising, notably on the basis of initial studies in patients with diffuse in-stent restenosis (ISR). At present, however, a number of questions regarding long-term efficacy and safety remain, specifically in indications other than diffuse ISR. The results of the evaluation of different substances, balloon systems and clinical indications will determine the long-term success of DEBs. PMID:21160601

  3. Accelerated Recovery of Endothelium Function after Stent Implantation with the Use of a Novel Systemic Nanoparticle Curcumin.

    PubMed

    Lu, Qi; Ye, Fang; Yang, Xiangjun; Gu, Qingqing; Wang, Peng; Zhu, Jianhua; Shen, Li; Gong, Feirong

    2015-01-01

    Curcumin was reported to exhibit a wide range of pharmacological effects including antioxidant, anti-inflammatory, and antiproliferative activities and significantly prevent smooth muscle cells migration. In the present study, a novel kind of curcumin loaded nanoparticles (Cur-NP) has been prepared and characterized with the aim of inhibiting inflammation formation and accelerating the healing process of the stented arteries. Cur-NP was administrated intravenously after stent implantation twice a week and detailed tissue responses were evaluated. The results demonstrated that intravenous administration of Cur-NP after stent implantation accelerated endothelial cells restoration and endothelium function recovery and may potentially be an effective therapeutic alternative to reduce adverse events for currently available drug eluting stents.

  4. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenton, James, E-mail: jlenton@doctors.org.u; Davies, John; Homer-Vanniasinkam, S.

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms withmore » stent-grafts has not been previously reported in the adolescent population.« less

  5. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    PubMed

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is required to confirm these promising results. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  6. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    PubMed

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  7. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    PubMed

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  8. Controlled delivery of paclitaxel from stent coatings using poly(hydroxystyrene-b-isobutylene-b-hydroxystyrene) and its acetylated derivative.

    PubMed

    Sipos, Laszlo; Som, Abhijit; Faust, Rudolf; Richard, Robert; Schwarz, Marlene; Ranade, Shrirang; Boden, Mark; Chan, Ken

    2005-01-01

    A poly(styrene-b-isobutylene-b-styrene) (SIBS) triblock polymer is employed as the polymer drug carrier for the TAXUS Express2 Paclitaxel-Eluting Coronary Stent system (Boston Scientific Corp.). It has been shown that the release of paclitaxel (PTx) from SIBS can be modulated by modification of either drug-loading ratio or altering the triblock morphology by blending. In the present work, results toward achieving release modulation of PTx by chemical modification of the styrenic portion (using hydroxystyrene or its acetylated version) of the SIBS polymer system are reported. The synthesis of the precursor poly[(p-tert-butyldimethylsilyloxystyrene)]-b-isobutylene-b-[(p-tert-butyldimethylsilyloxystyrene] triblock copolymers was accomplished by living sequential block copolymerization of isobutylene (IB) and p-(tert-butyldimethylsiloxy)styrene (TBDMS) utilizing the capping-tuning technique in a one-pot procedure in methylcyclohexane/CH3Cl at -80 degrees C. This procedure involved the living cationic polymerization of IB with the 5-tert-butyl-1,3-bis(1-chloro-1-methylethyl)benzene/TiCl4 initiating system and capping of living difunctional polyisobutylene (PIB) chain ends with 1,1-ditolylethylene (DTE) followed by addition of titanium(IV) isopropoxide (Ti(OIp)4) to lower the Lewis acidity before the introduction of TBDMS. Deprotection of the product with tetrabutylammonium fluoride yielded poly(hydroxystyrene-b-isobutylene-b-hydroxystyrene), which was quantitatively acetylated to obtain the acetylated derivative. The hydroxystyrene and acetoxystyrene triblock copolymers have acceptable mechanical properties for use as drug delivery coatings for coronary stent applications. It was concluded that the hydrophilic nature of the endblocks and polarity effects on the drug/polymer miscibility lead to enhanced release of PTx from these polymers. The drug-polymer miscibility was confirmed by differential scanning calorimetry and atomic force microscopy evaluations.

  9. Relay NBS Graft with the Plus Delivery System to Improve Deployment in Aortic Arch with Small Radius Curve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara

    The purpose of this report is to describe deployment of the Relay NBS Thoracic Stent Graft with the Plus Delivery System (Bolton Medical, Sunrise, FL) in a flexible resin arch model with a 15-mm radius curve as well as our preliminary clinical results. The Relay NBS graft with the Plus Delivery System was evaluated by way of bench testing, which was performed with stent grafts with diameters ranging from 24 to 46 mm and lengths ranging from 100 to 250 mm in flexible resin arch models with a 15-mm arch radius of curvature. The deployment sequence was analyzed. The Relaymore » NBS graft with the Plus Delivery System was deployed in two patients, respectively, having a 6.5-cm penetrating aortic ulcer of the proximal third of the descending thoracic aorta and a DeBakey type-I aortic dissection with chronic false lumen dilatation after surgery due to an entry site at the distal thoracic aorta. Bench tests showed proper conformation and apposition of the Relay NBS graft with the Plus Delivery System in the flexible resin model. This stent graft was deployed successfully into the two patients with a correct orientation of the first stent and without early or late complications. The Relay NBS graft with the Plus Delivery System ensures an optimal conformation and apposition of the first stent in the aortic arch with a small radius of curvature.« less

  10. Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type.

    PubMed

    Camenzind, Edoardo; Boersma, Eric; Wijns, William; Mauri, Laura; Rademaker-Havinga, Tessa; Ordoubadi, Farzin Fath; Suttorp, Maarten J; Al Kurdi, Mohammad; Steg, Ph Gabriel

    2014-08-01

    To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  11. Interaction of intraluminal tissue and coronary sinus lead stabilized with stent placement.

    PubMed

    Balázs, Tibor; Merkely, Béla; Bognár, Eszter; Zima, Endre

    2013-04-01

    The aim of our investigation was to examine the intraluminal interaction of the vascular tissue and the implanted coronary sinus lead stabilized with stent on two human hearts removed before transplantation. The coronary sinus lumen was sectioned under operational microscope and opened carefully. The leads and stents were found separately positioned beside each other completely covered by an intact intimal tissue layer. No sign of occluding proliferative tissue was observed. Stent fixation technique and extraction of the CS lead in our cases did not have any particular damaging effect on the vascular system. © 2012 Wiley Periodicals, Inc.

  12. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    PubMed

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  13. Extracranial carotid angioplasty and stenting. Initial results and short-term follow-up.

    PubMed

    Vozzi, C R; Rodriguez, A O; Paolantonio, D; Smith, J A; Wholey, M H

    1997-01-01

    Carotid percutaneous transluminal angioplasty, with or without stent implantation, is becoming another therapeutic option for carotid revascularization. To evaluate the feasibility and effectiveness of the technique, from October of 1995 to March of 1997, we performed 24 percutaneous transluminal angioplasty procedures in 22 patients with severe extracranial carotid artery stenosis. Three common carotid and 21 internal carotid arteries were treated, and 19 procedures included stent implantation using nonarticulated PALMAZ stents (P154 and P204). Twelve patients were asymptomatic and 10 patients were symptomatic; 2 of the symptomatic patients had complete obstruction of the internal carotid artery that was successfully recanalized. Technical and angiographic success was achieved in 23 of 24 procedures, with the carotid artery obstruction diminishing from 85.6% +/- 8.5% to 5.7% +/- 3.2% (P < 0.001). Average stenosis length was 12.5 +/- 3.1 mm, and mean time of carotid occlusion during balloon inflation was 11.5 +/- 2.5 seconds. Three patients experienced transitory seizures during the procedure prior to dilation, 1 patient had a minor stroke with complete recovery within 72 hours, and 1 patient had a major stroke and died 45 days after the procedure. Clinical follow-up was achieved in all patients (mean, 10.5 +/- 7.2 months) and angiographic follow-up in 16 patients (mean, 6.3 +/- 1.2 months). The results obtained in this initial experience provide adequate support to continue further evaluation of this new therapeutic strategy.

  14. Canadian experience with the pipeline embolization device for repair of unruptured intracranial aneurysms.

    PubMed

    O'Kelly, C J; Spears, J; Chow, M; Wong, J; Boulton, M; Weill, A; Willinsky, R A; Kelly, M; Marotta, T R

    2013-02-01

    Flow-diverting stents, such as the PED, have emerged as a novel means of treating complex intracranial aneurysms. This retrospective analysis of the initial Canadian experience provides insight into technical challenges, clinical and radiographic outcomes, and complication rates after the use of flow-diverting stents for unruptured aneurysms. Cases were compiled from 7 Canadian centers between July 2008 and December 2010. Each center prospectively tracked their initial experience; these data were retrospectively updated and pooled for analysis. During the defined study period, 97 cases of unruptured aneurysm were treated with the PED, with successful stent deployment in 94 cases. The overall complete or near-complete occlusion rate was 83%, with a median follow-up at 1.25 years (range 0.25-2.5 years). Progressive occlusion was witnessed over time, with complete or near-complete occlusion in 65% of aneurysms followed through 6 months, and 90% of aneurysms followed through 1 year. Multivariate analysis found previous aneurysm treatment and female sex predictive of persistent aneurysm filling. Most patients were stable or improved (88%), with the most favorable outcomes observed in patients with cavernous carotid aneurysms. The overall mortality rate was 6%. Postprocedural aneurysm hemorrhage occurred in 3 patients (3%), while ipsilateral distal territory hemorrhage was observed in 4 patients (3.4%). Flow-diverting stents represent an important tool in the treatment of complex intracranial aneurysms. The relative efficacy and morbidity of this treatment must be considered in the context of available alternate interventions.

  15. Implantability, Complications, and Follow-Up After Transjugular Intrahepatic Portosystemic Stent-Shunt Creation With the 6F Self-Expanding Sinus-SuperFlex-Visual Stent.

    PubMed

    Spira, Daniel; Wiskirchen, Jakub; Lauer, Ulrich; Ketelsen, Dominik; Nikolaou, Konstantin; Wiesinger, Benjamin

    2016-07-01

    The transjugular intrahepatic portosystemic stent-shunt (TIPSS) builds a shortcut between the portal vein and a liver vein, and represents a sophisticated alternative to open surgery in the management of portal hypertension or its complications. To describe clinical experiences with a low-profile nitinol stent system in TIPSS creation, and to assess primary and long-term success. Twenty-six patients (5 females, 21 males; mean age 54.6 years) were treated using a low-profile 6F self-expanding sinus-SuperFlex-Visual stent system. The indication for TIPSS creation was refractory bleeding in 9 of the 26 patients, refractory ascites in 18 patients, and acute thrombosis of the portal vein confluence in one patient. Portosystemic pressure gradients before and after TIPSS, periprocedural and long-term complications, and the time to orthotopic liver transplantation (OLT) or death were recorded. The portosystemic pressure gradient was significantly reduced, from 20.9 ± 6.3 mmHg before to 8.2 ± 2.3 mmHg after TIPSS creation (P < 0.001). Procedure-related complications included acute tract occlusion (n = 2), liver hematoma (n = 1), hepatic encephalopathy (n = 1), and cardiac failure (n = 1). Three of the 26 patients had late-onset TIPSS occlusion (at 12, 12, and 39 months after TIPSS creation). Three patients died within one week after the procedure due to their poor general condition (multiorgan failure, acute respiratory distress syndrome, necrotizing pancreatitis, and aspiration pneumonia). Another four patients succumbed to their underlying advanced liver disease within one year after TIPSS insertion. Seven patients underwent OLT at a mean time of 9.4 months after TIPSS creation. The sinus-SuperFlex-Visual stent system can be safely deployed as a TIPSS device. The pressure gradient reduction was clinically sufficient to treat the patients' symptoms, and periprocedural complications were due to the TIPSS procedure per se rather than to the particular stent system employed in this study.

  16. Ultra-low profile Ovation device: is it the definitive solution for EVAR?

    PubMed

    de Donato, G; Setacci, F; Sirignano, P; Galzerano, G; Borrelli, M P; di Marzo, L; Setacci, C

    2014-02-01

    When Juan Parodi implanted an endograft in a human body for the first time on September 7, 1990 in Buenos Aires, Argentina, the delivery system of the handmade device was primitive, extremely rigid, and had a bulky profile of 27 French (F). Since then, stent-graft technology has evolved rapidly, limitations of earlier-generation devices have been overtaken, and endovascular aneurysm repair (EVAR) eligibility has increased enormously. Nevertheless (still) challenging aortoiliac anatomy such as short and complex proximal aortic neck seal zones and narrow access vessels are responsible for EVAR ineligibility in up to 50% of cases. The Ovation Prime abdominal stent-graft system (TriVascular, Inc., Santa Rosa, CA, USA) is a trimodular device designed with the aortic body delivered via a flexible, hydrophilic-coated, ultra-low profile catheter (14-F outer diameter - OD). The aortic body is provided with a suprarenal nitinol stent with anchors that provide active fixation, while a network of rings and channels that are inflated with a low-viscosity radiopaque polymer during stent-graft deployment, provides effective sealing. The previous EVAR technology aimed to both anchor and seal using stents combined with fabric, with neither optimized for their roles and each forced to compete for the same space within their delivery catheters, which inevitably led to larger profile of the delivery system. The technical revolution of the Ovation endograft includes the idea to truly uncouple the stages of stent-graft fixation and seal during the procedure. In the Ovation endograft platform, stent and fabric are not competing the same space within the delivery system and an ultra-low profile delivery can be achieved without compromise. With such a low-profile delivery catheter, approximately 90% of men and 70% of women with abdominal aortic aneurysm have access vessel diameters considered fit for endovascular repair. The aim of this review paper was to analyze the main properties of Ovation endograft, to emphasize the advantage of the ultra-low profile device, and to sum up current literature.

  17. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months.more » Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.« less

  18. Clinical Outcomes of Drug-Coated Balloons in Coronary Artery Disease Unsuitable for Drug-Eluting Stent Implantation.

    PubMed

    Iijima, Raisuke; Kougame, Norihiro; Hara, Hidehiko; Moroi, Masao; Nakamura, Masato

    2018-06-12

    The aim of this study was to investigate whether drug-coated balloon (DCB) treatment is effective for de novo coronary lesions that are unsuitable for drug-eluting stent (DES) implantation.Methods and Results:This retrospective study included 118 de novo lesions that were not suitable for DES implantation. Of the lesions, 40% was treated because of very small vessel disease. Patients with planned non-cardiac surgery and at high bleeding risk were 3% and 19%, respectively, and lesions that easily develop stent fracture comprised 26%. Clinically driven target lesion revascularization (TLR) was the primary endpoint. The rate of suboptimal lesion preparation before DCB treatment was set as the secondary endpoint. Optimal lesion preparation was defined as acquisition of Thrombolysis in Myocardial Infarction flow grade 3, minor coronary dissection, and residual stenosis ≤30%. The rate of suboptimal lesion preparation was 2.5% and 3 patients needed bail-out stenting. Accordingly, 115 patients were treated with a DCB. Clinically driven TLR had occurred in 8 patients (7.0%) at the 8-month follow-up. The presence of chronic total occlusion was identified as an independent predictor for TLR (odds 11.57; 95% confidence interval, 1.38-135.54; P=0.02). For lesions that are unsuitable for stent implantation, stent-less intervention using a DCB should be considered initially. The present study also highlighted that lesion preparation is key to a successful DCB strategy.

  19. Origins of medical innovation: the case of coronary artery stents.

    PubMed

    Xu, Shuai; Avorn, Jerry; Kesselheim, Aaron S

    2012-11-01

    Innovative medical devices make major contributions to patient welfare, and coronary stents have been among the most important device developments of recent decades. However, the origins of such breakthrough medical technologies remain poorly understood. Using a comprehensive database of patents, we identified all individuals and institutions that developed intellectual property related to stent technology early in its development process. The patents were categorized and described using a predetermined qualitative coding strategy. We found 245 granted patents related to bare metal coronary artery stents from 1984 (when the first patent issued in this field) to 1994 (after the first stents were approved). Each year showed an increase in the number of patent filings: from 1 in 1984 to 97 in 1994. The largest fraction of patents was issued to private entities (44.9% of the total). Public companies, individual inventors, and nonprofit institutions represented 31.4%, 18.0%, and 5.7%, respectively. The top 10 most-cited patents in the field were dominated by 2 private entities, Expandable Grafts Partnership and Cook Inc, organizations created by or dependent on the work of independent academic physician-inventors. Coronary artery stent technology first arose from individual physician-inventors within academic medical centers and their associated private companies. After these initial innovations were in place, the field became dominated by large public companies. This history suggests that policies aimed at encouraging transformative medical device development would have their greatest effect if focused on individual inventors and scientists performing the early stages of technology development.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozkan, Ugur, E-mail: radugur@yahoo.com; Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Tercan, Fahri, E-mail: ftercan@yahoo.com

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques weremore » successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.« less

  1. Update on perioperative care of the cardiac patient for noncardiac surgery.

    PubMed

    Ghadimi, Kamrouz; Thompson, Annemarie

    2015-06-01

    The current review will address key topics and recommendations of the recent 2014 update of the American College of Cardiology and American Heart Association clinical practice guideline for the perioperative cardiovascular evaluation and management of patients undergoing noncardiac surgery. The completely rewritten guideline provides a stepwise approach for the identification and management of patients at highest risk for major adverse cardiac events and discusses new or updated recommendations. For example, β-blockers should be continued perioperatively but treatment should not be initiated within 24 h of noncardiac surgery. Angiotensin-converting enzyme inhibitors should be continued, but if held, may be restarted as soon as feasible. Routine aspirin therapy is not recommended without previous coronary stent implantation or risk assessment for myocardial ischemia. Elective noncardiac surgery should not be performed within 30 days of bare metal stent or 12 months of drug-eluting stent implantation because of in-stent thrombosis as well as bleeding risk from dual antiplatelet therapy during surgery. Noncardiac surgery may be considered, however, in patients on antiplatelet agents 180 days after drug-eluting stent placement if risk of surgical delay exceeds risk of stent thrombosis from cessation of antiplatelet therapy. In conclusion, this review will discuss the important topics from the 2014 American College of Cardiology/American Heart Association guideline in order to provide the perioperative physician with the most recent evidence necessary to minimize major adverse cardiac events in patients undergoing noncardiac surgery.

  2. Long-term complications of JJ stent and its management: A 5 years review.

    PubMed

    Ray, Rajendra Prasad; Mahapatra, Rajkumar Singha; Mondal, Partha Pratim; Pal, Dilip Kumar

    2015-01-01

    To assess the long term complications of JJ stent, the management of complications and the role of endoscopic approach to manage these complications. Nineteen patients with indwelling JJ stent for a duration of more than 6 months were included in this study. Patients were assessed with X-ray KUB, USG KUB, blood urea, creatinine and DTPA renogram. Data were analyzed by Microsoft excel 2007. Out of 19 patients 12 (63.16%) were male and 7 (36.84%) were female. The mean age was 39.78 ± 13.69 years., Mean duration for which the stent was in situ was 29.56 months. The most common complication was broken stent, in 11 cases (57.89%). Other complications were migration in 5 (26.32%), encrustation in 2 (10.52%) and 1 case of (5.26%) stone formation. Eighteen cases were managed by endoscopic approaches. A total of 22 procedures were performed to treat the complications. Eleven cases were managed by a single procedure and 8 patients required multiple procedures. All were managed successfully with no death reported. Post-operative complications were seen in eight cases (42.11%). JJ stent related long-term complications are not uncommon and are usually seen after 6 months of indwelling time. Endourological procedure should be the initial approach with a high success rate. Coordinated use multimodality and technology helps in management of difficult cases. Open surgery is rarely required. Prevention of the complication by judicious use and early removal is the cornerstone.

  3. Biomechanical analysis on stent materials used as cardiovascular implants

    NASA Astrophysics Data System (ADS)

    Kumar, Vasantha; Ramesha, C. M.; Sajjan, Sudheer S.

    2018-04-01

    Atherosclerosis is the most common cause of death in the world, accounting for 48% of all deaths in the world. Atherosclerosis, also known as coronary artery disease occurs when excess cholesterol attaches itself to the walls of blood vessels. Coronary stent implantation is one of the most important procedures to treating coronary artery disease such atherosclerosis. Due to its efficiency, flexibility and simplicity, the use of coronary stents procedures has increased rapidly. In order to have better output of stent implantation, it is needed to study and analyze the biomechanical behavior of this device before manufacturing and put into use. Biomaterials are commonly used for medical application in cardiovascular stent implantation. A biomaterial is a non-viable material used as medical implant, so it is intended to interact with biological system. In this paper, an explicit dynamic analysis is used for analyzing the biomechanical behavior of cardiovascular stent by using finite element analysis tool, ABAQUS 6.10. Results showed that a best suitable biomaterial for cardiovascular stent implants, which exhibits an outstanding biocompatibility and biomechanical characteristics will be aimed at which will be quite useful to the human beings worldwide.

  4. Efficacy of plastic stent placement inside bile ducts for the treatment of unresectable malignant hilar obstruction (with videos).

    PubMed

    Kaneko, Takashi; Sugimori, Kazuya; Shimizu, Yuro; Miwa, Haruo; Kameta, Eri; Koh, Ryonho; Numata, Kazushi; Tanaka, Katsuaki; Maeda, Shin

    2014-05-01

    Recent reports have addressed the utility of plastic stent (PS) placement inside bile ducts for treating biliary obstructions. Here, we evaluated the utility and safety of PS placement inside bile ducts for treating unresectable malignant hilar biliary obstruction. We conducted a retrospective study of 27 patients with unresectable malignant hilar biliary obstruction who underwent intraductal modified PS placement. We modified the PS, by cutting off the distal end to facilitate insertion through the papilla of Vater, and attached a nylon thread to the distal end for removal. We evaluated complications, the time to recurrent biliary obstruction (TRBO), and removability. Bilateral stenting was performed in nine of the 27 patients. Mild acute pancreatitis occurred in one patient (4%). Recurrent biliary obstruction (RBO) occurred in 16 patients (59%), with a median TRBO of 190 days (95% confidence interval: 174-205 days). Reintervention was necessary in 13 of the 16 patients (81%) with RBO, and we were able to remove the initial stents in all the patients who required reintervention. A relatively long stent patency period (>6 months) and removability make placement of a modified PS inside bile ducts a viable treatment for unresectable malignant hilar biliary obstruction. © 2013 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  5. Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma.

    PubMed

    Spiegel, Detlev; Wetzel, Wolfgang; Haffner, David S; Hill, Richard A

    2007-01-01

    This study was undertaken to evaluate the efficiency of a trabecular micro-bypass stent designed to allow direct aqueous drainage from the anterior chamber into Schlemm's canal in patients with glaucoma. In this prospective case series of 6 patients with open-angle glaucoma, the microstent was inserted ab interno under local anesthesia in an ophthalmic operating room. Patients were seen postoperatively at 1 to 2 d, 1 wk, and 1, 2, 6, and 12 mo. All stents were successfully placed within Schlemm's canal. Mean intraocular pressure (IOP) at preoperative baseline was 20.2+/-6.3 mm Hg (range, 14-31 mm Hg). Mean IOP decreased during the immediate postoperative period to approximately 12 to 13 mm Hg and was stabilized at 14 to 15 mm Hg with reduction of medication throughout 1 y of follow-up. No major complications occurred. According to observations reported in this feasibility study, the microstent was effective in reducing IOP and in decreasing the number of glaucoma medications required to control IOP. Implantation procedures were safe, and stents remained in place throughout the follow-up period. None of the complications traditionally associated with filtering surgery were reported. Further research on this stent in a larger group of patients is needed to assess its role in glaucoma therapy.

  6. Intracoronary stent implantation: new approach using a monorail system and new large-lumen 7F catheters from the brachial route.

    PubMed

    Jenny, D B; Robert, G P; Fajadet, J C; Cassagneau, B G; Marco, J

    1992-04-01

    In this brief report we describe a case of successful multivessel PTCA with intracoronary stent implantation using a new large-lumen 7F catheter from the left brachial approach. The application of this technique should be considered for intravascular stent implantation when anticoagulation ideally should not be interrupted or in anatomical situations limiting femoral vascular access.

  7. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca; Saluja, Jasdeep S.

    2007-07-15

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm.more » The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is associated with good mid-term patency and may exceed historical observations with prior use of Wallstents.« less

  8. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    PubMed

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  9. In vitro analysis of type II endoleaks and aneurysm sac pressurization on longitudinal stent-graft displacement.

    PubMed

    Knowles, Martyn; Pellisar, Tiago; Murphy, Erin H; Stanley, Gregory A; Hashmi, Abraham F; Arko, M Zachary; Arko, Frank R

    2011-08-01

    To evaluate the effects of type II endoleaks and sac pressurization on stent-graft displacement following endovascular aneurysm repair (EVAR). Experimental silicone infrarenal aneurysm (6-cm) models were "treated" with a Talent stent-graft deployed with 20-mm proximal and distal landing zones. Inflow and outflow vessels were created as part of the silicone model to control flow into the aneurysm sac. All aneurysm models were uniform, with a diameter neck of 31 mm, a neck length of 20 mm, and iliac artery diameters of 16 mm. The aortic model was secured in a water bath to a pulsatile pump under physiological conditions; the output phase ratio (%systole/%diastole) was set at 65/35 with a pump rate of 80 beats per minute. Commercially available bifurcated stent-grafts were then displaced in vitro utilizing a linear motion apparatus attached to a force gauge. The mean arterial pressure (MAP) and pulse pressure (PP) at the aortic inflow were 60.1 ± 3.1 and 38.3 ± 7.8 mmHg, respectively. Peak force to cause initial stent-graft migration with and without a type II endoleak was recorded and compared. In aneurysm sacs with no endoleak, the MAP and sac PP were 32 ± 6.4 and 6 ± 1.3 mmHg, respectively (p<0.01). In aneurysm sacs with a type II endoleak, the MAP and sac PP were 54.1 ± 9.7 and 16.1 ± 4.1 mmHg, respectively (p<0.02). Peak force to initiate migration was 16.0 ± 1.41 N (range 15-18) with no endoleak vs. 23.2 ± 2.2 N (range 20-25) in those with a type IIa endoleak and 23.5 ± 2.5 N (range 20-26) in those with a type IIb endoleak (p<0.001). Type II endoleaks are associated with a significantly increased sac pressure. Increased sac pressurization from type II endoleaks results in a significantly greater force to displace a stent-graft longitudinally. Type II endoleaks may therefore inhibit migration and offer a benefit following EVAR; however, clinical correlation of these results is required.

  10. A break-even price calculation for the use of sirolimus-eluting stents in angioplasty.

    PubMed

    Galanaud, Jean-Philippe; Delavennat, Juliette; Durand-Zaleski, Isabelle

    2003-03-01

    One of the major complications of angioplasty is the early occurrence of restenosis requiring a repeat procedure. When bare-metal stents are used, clinical restenosis results in a repeat procedure in 10% to 15% of cases. Based on the results of an international, randomized clinical trial, the use of sirolimus-eluting stents reduces this risk. The aims of this study were to calculate the theoretical break-even price for sirolimus-eluting stents in France, the Netherlands, and the United States, and to determine the additional health care cost per patient. The break-even price was calculated by adding the savings resulting from a 15% decrease in the rate of clinical restenosis to the price of bare-metal stents. Costs were computed from the viewpoint of the health care system, exclusive of other societal costs. The break-even prices were 1291 Euro to 1489 Euro in France, 2028 Euro in the Netherlands, and 2708 Euroin the United States (1.00 Euro = 1.00 US dollar in purchasing power parity). These results indicate that the commercial price of sirolimuseluting stents will increase hospital spending for patients undergoing angioplasty by 17% to 55% per patient. This additional cost to the health care system should be discussed in view of possible productivity savings and improved quality of life for patients.

  11. Outcome and management of pacemaker-induced superior vena cava syndrome.

    PubMed

    Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei

    2014-11-01

    We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.

  12. Esophageal leiomyoma in a dog causing esophageal distension and treated by transcardial placement of a self-expanding, covered, nitinol esophageal stent.

    PubMed

    Robin, Elisabeth M; Pey, Pascaline B; de Fornel-Thibaud, Pauline; Moissonnier, Pierre H M; Freiche, Valérie

    2018-02-01

    CASE DESCRIPTION A 10-year-old spayed female Rottweiler was referred for evaluation because of a 2-month history of regurgitation and weight loss, despite no apparent change in appetite. The dog had received antiemetic and antacid treatment, without improvement. CLINICAL FINDINGS Physical examination revealed a low body condition score (2/5), but other findings were unremarkable. Diffuse, global esophageal dilatation was noted on plain thoracic radiographs, and normal motility was confirmed through videofluoroscopic evaluation of swallowing. Transhepatic ultrasonographic and CT examination revealed a circumferential, intraparietal lesion in the distal portion of the esophagus causing distal esophageal or cardial subobstruction and no metastases. Incisional biopsy of the lesion was performed, and findings of histologic examination supported a diagnosis of esophageal leiomyoma. TREATMENT AND OUTCOME In view of numerous possible complications associated with esophageal surgery, the decision was made to palliatively treat the dog by transcardial placement of a self-expanding, covered, nitinol esophageal stent under endoscopic guidance. Two weeks after stent placement, radiography revealed complete migration of the stent into the gastric lumen. Gastrotomy was performed, and the stent was replaced and fixed in place. Twenty-four months after initial stent placement, the dog had a healthy body condition and remained free of previous clinical signs. CLINICAL RELEVANCE Diffuse benign muscular neoplasia should be considered as a differential diagnosis for acquired esophageal dilatation in adult and elderly dogs. In the dog of this report, transcardial stent placement resulted in resolution of the clinical signs, with no apparent adverse effect on digestive function. The described procedure could be beneficial for nonsurgical treatment of benign esophageal tumors in dogs.

  13. One-Year Clinical Outcomes of Patients Presenting With ST-Segment Elevation Myocardial Infarction Caused by Bifurcation Culprit Lesions Treated With the Stentys Self-Apposing Coronary Stent: Results From the APPOSITION III Study.

    PubMed

    Grundeken, Maik J; Lu, Huangling; Vos, Nicola; IJsselmuiden, Alexander; van Geuns, Robert-Jan; Wessely, Rainer; Dengler, Thomas; La Manna, Alessio; Silvain, Johanne; Montalescot, Gilles; Spaargaren, René; Tijssen, Jan G P; de Winter, Robbert J; Wykrzykowska, Joanna J; Amoroso, Giovanni; Koch, Karel T

    2017-08-01

    To investigate outcomes in patients with ST-segment elevation myocardial infarction (STEMI) after treatment with the Stentys self-apposing stent (Stentys SAS; Stentys S.A.) for bifurcation culprit lesions. The nitinol, self-expanding Stentys was initially developed as a dedicated bifurcation stent. The stent facilitates a provisional strategy by accommodating its diameter to both the proximal and distal reference diameters and offering an opportunity to "disconnect" the interconnectors, opening the stent toward the side branch. The APPOSITION (a post-market registry to assess the Stentys self-expanding coronary stent in acute myocardial infarction) III study was a prospective, multicenter, international, observational study including STEMI patients undergoing primary percutaneous coronary intervention (PCI) with the Stentys SAS. Clinical endpoints were evaluated and stratified by bifurcation vs non-bifurcation culprit lesions. From 965 patients included, a total of 123 (13%) were documented as having a bifurcation lesion. Target-vessel revascularization (TVR) rates were higher in the bifurcation subgroup (16.4% vs 10.0%; P=.04). Although not statistically significant, other endpoints were numerically higher in the bifurcation subgroup: major adverse cardiac events (MACE; 12.7% vs 8.8%), myocardial infarction (MI; 3.4% vs 1.8%), and definite/probable stent thrombosis (ST; 5.8% vs 3.1%). However, when postdilation was performed, clinical endpoints were similar between bifurcation and non-bifurcation lesions: MACE (8.7% vs 8.4%), MI (1.2% vs 0.7%), and definite/probable ST (3.7% vs 2.4%). The use of the Stentys SAS was safe and feasible for the treatment of bifurcation lesions in the setting of primary PCI for STEMI treatment with acceptable 1-year cardiovascular event rates, which improved when postdilation was performed.

  14. Predictors of Long-Term Results After Treatment of Iliac Artery Obliteration by Transluminal Angioplasty and Stent Deployment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Funovics, M.A.; Lackner, B.; Cejna, M.

    2002-10-15

    Purpose: To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate the influence of vascular comorbidity, lesion length, stent placement and lesion coverage as possible predictors of outcome. Methods: Between January 1994 and December 1999, 80 iliac recanalizations were performed on 78 patients, median age 61.1 {+-}11.5 (SD) years. All patients were followed up by clinical examinations, duplex ultrasound and intravenous digital subtraction angiography. Mean follow-up time was 2.0 {+-} 1.53 (SD) years.Multivariate Cox regression analysis was used to determine the influence of cofactors on patency. Results: One, 2more » and 4 years after recanalization, primary patency was 78.1%, 74.5% and 64.0%; secondary patency was 88.8%, 88.8% and 77.9%, respectively.Patients with shorter occlusions, complete lesion coverage and patent ipsilateral femoral arteries had significantly longer patency rates.Complications included inguinal hematoma (n=1), technical failure (n=3) aortic dissection (n=1), embolic occlusions (n=7), gluteal claudication (n=1) and genital necrosis after subsequent urethral surgery in one patient with contralateral occlusion and ipsilateral overstenting of the internal iliac artery with subsequent stenosis. Complications were of permanent clinical significance in seven of 78 (9%) of the patients. In 17 (22%) cases, percutaneous reintervention was performed with angioplasty in the stent (n=16) or deployment of a new stent (n=1). Conclusion: Endoluminal stent placement has its place in an interdisciplinary therapeutic approach as a viable therapeutic alternative to major transabdominal bypass surgery and can be performed with comparable complication rates. Patients with short occlusions, patent femoral arteries, and stents covering the entire occlusion have significant longer patency.« less

  15. Robotic-assisted percutaneous coronary intervention--filling an unmet need.

    PubMed

    Carrozza, Joseph P

    2012-02-01

    Percutaneous coronary intervention (PCI) has undergone a remarkable evolution over the past 25 years. Initially, the procedure was limited to relatively straightforward lesions and was associated with significant risk and unpredictable long-term efficacy. With the incorporation of new technologies such as stents, the safety and efficacy of the procedure has improved dramatically. However, the fundamental way in which the procedure is performed has changed little since the time of Gruntzig's first successful case. Cumulative exposure to ionizing radiation, orthopedic injuries resulting from wearing shielding aprons, and fatigue from standing for hours at the table have made the catheterization laboratory a "high-risk workplace" for the interventional cardiologist. Robotic-assisted PCI was developed to allow the operator to precisely manipulate angioplasty guidewires, balloons, and stents from a radiation-shielded cockpit. A small first-in-man study demonstrated that PCI can be performed with robotic assistance. The pivotal Percutaneous Robotically Enhanced Coronary Intervention Study trial is currently enrolling patients and evaluating the safety and efficacy of the CorPath® robotically assisted PCI system.

  16. Endoscopic and Photodynamic Therapy of Cholangiocarcinoma

    PubMed Central

    Meier, Benjamin; Caca, Karel

    2016-01-01

    Background Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Methods/Results Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. Conclusion More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA. PMID:28229075

  17. Endoscopic and Photodynamic Therapy of Cholangiocarcinoma.

    PubMed

    Meier, Benjamin; Caca, Karel

    2016-12-01

    Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA.

  18. Dynamic simulation of stent deployment - effects of design, material and coating

    NASA Astrophysics Data System (ADS)

    Schiavone, A.; Zhao, L. G.; Abdel-Wahab, A. A.

    2013-07-01

    Dynamic finite-element simulations have been carried out to study the effects of cell design, material choice and drug eluting coating on the mechanical behaviour of stents during deployment. Four representative stent designs have been considered, i.e., Palmaz-Schatz, Cypher, Xience and Endeavor. The former two are made of stainless steel while the latter two made of Co-Cr alloy. Geometric model for each design was created using ProEngineer software, and then imported into Abaqus for simulation of the full process of stent deployment within a diseased artery. In all cases, the delivery system was based on the dynamic expansion of a polyurethane balloon under applied internal pressure. Results showed that the expansion is mainly governed by the design, in particular open-cell design (e.g. Endeavor) tends to have greater expansion than closed-cell design (e.g. Cypher). Dogboning effect was strong for slotted tube design (e.g. Palmaz-Schatz) but reduced significantly for sinusoidal design (e.g. Cypher). Under the same pressure, the maximum von Mises stress in the stent was higher for the open-cell designs and located mostly at the inner corners of each cell. For given deformation, stents made of Co-Cr alloys tend to experience higher stress level than those made of stainless steels, mainly due to the difference in material properties. For artery-plaque system, the maximum stress occurred on the stenosis and dogboning led to stress concentration at the ends of the plaque. The drug eluting coating affected the stent expansion by reducing the recoiling phenomenon considerably, but also raised the stress level on the stent due to property mismatch.

  19. When is carotid angioplasty and stenting the cost-effective alternative for revascularization of symptomatic carotid stenosis? A Canadian health system perspective.

    PubMed

    Almekhlafi, M A; Hill, M D; Wiebe, S; Goyal, M; Yavin, D; Wong, J H; Clement, F M

    2014-02-01

    Carotid revascularization procedures can be complicated by stroke. Additional disability adds to the already high costs of the procedure. To weigh the cost and benefit, we estimated the cost-utility of carotid angioplasty and stenting compared with carotid endarterectomy among patients with symptomatic carotid stenosis, with special emphasis on scenario analyses that would yield carotid angioplasty and stenting as the cost-effective alternative relative to carotid endarterectomy. A cost-utility analysis from the perspective of the health system payer was performed by using a Markov analytic model. Clinical estimates were based on a meta-analysis. The procedural costs were derived from a microcosting data base. The costs for hospitalization and rehabilitation of patients with stroke were based on a Canadian multicenter study. Utilities were based on a randomized controlled trial. In the base case analysis, carotid angioplasty and stenting were more expensive (incremental cost of $6107) and had a lower utility (-0.12 quality-adjusted life years) than carotid endarterectomy. The results are sensitive to changes in the risk of clinical events and the relative risk of death and stroke. Carotid angioplasty and stenting were more economically attractive among high-risk surgical patients. For carotid angioplasty and stenting to become the preferred option, their costs would need to fall from more than $7300 to $4350 or less and the risks of the periprocedural and annual minor strokes would have to be equivalent to that of carotid endarterectomy. In the base case analysis, carotid angioplasty and stenting were associated with higher costs and lower utility compared with carotid endarterectomy for patients with symptomatic carotid stenosis. Carotid angioplasty and stenting were cost-effective for patients with high surgical risk.

  20. Percutaneous Transcholecystic Biliary Interventions Using Gallbladder Anchors: Feasibility Study in the Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E., E-mail: jloper@lsuhsc.edu; Kirsch, David; Qian Zhong

    2005-05-15

    The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiogramsmore » were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.« less

  1. Percutaneous transcholecystic biliary interventions using gallbladder anchors: feasibility study in the swine.

    PubMed

    Lopera, Jorge E; Kirsch, David; Qian, Zhong; Ruiz, Bernardo; Brazzini, Augusto; Gonzales, Arturo; Castaneda-Zuniga, Wilfrido

    2005-01-01

    The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiograms were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.

  2. FiberNet--a new embolic protection device for carotid artery stenting.

    PubMed

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  3. Long-term results of permanent metallic stent implantation in the treatment of benign upper urinary tract occlusion.

    PubMed

    Li, Xun; He, Zhaohui; Yuan, Jian; Zeng, Guohua; He, Yongzhong; Lei, Ming

    2007-08-01

    The management of complicated benign upper urinary tract occlusion is extremely challenging, especially in patients unable to undergo an open operative procedure. We report the long-term results of a permanent metallic stent for benign upper urinary tract occlusion. From October 1995 to December 1998, 13 patients (8 men and 5 women, with a mean age of 43 years) with benign upper tract occlusion have been treated by metallic stent implantation. All patients had a nephrostomy tube to relieve the obstruction and the average time of the nephrostomy tube stay was 27 months, ranging from 3 to 131 months. The average length of occlusion was 2.7 cm, ranging from 1 to 3.6 cm. Ultrasonography, urography, diuresis renography and urine culture were performed every 3 months after stent insertion. Ureteroscopy was done when needed. The mean follow-up was 92 months (12-132 months). Ureteral patency was achieved in six patients and assisted patency with a Double-J stent was achieved in three patients. In two patients the kidney had to be removed because of progressive malfunction and in two patients the metal stent had to be extracted with the Holmium: YAG laser, burning it down due to the uncontrollable pyonephrosis. In three patients the ipsilateral flank pain recurred. One of these patients experienced urine leakage due to the initial nephrostomy tract: a ureteroscopy revealed a complete hyperplastic urothelial response. Proximal stone formations were found in 2 patients and all were removed by percutaneous nephrolithotomy (PCNL). No stent migration or fragmentation was observed. The implantation of metal stent is a safe and effective treatment for benign upper urinary tract occlusion, and has satisfying long-term outcome in selected cases. A further investigation is needed for its impact on the urodynamics of upper urinary tract.

  4. Percutaneous pulmonary valve implantation for free pulmonary regurgitation following conduit-free surgery of the right ventricular outflow tract.

    PubMed

    Cools, Bjorn; Brown, Stephen C; Heying, Ruth; Jansen, Katrijn; Boshoff, Derize E; Budts, Werner; Gewillig, Marc

    2015-01-01

    Pulmonary regurgitation (PR) following surgery of the right ventricular outflow tract (RVOT) is not innocent and leads to significant right heart dysfunction over time. Recent studies have demonstrated that percutaneous valves can be implanted in conduit free outflow tracts with good outcomes. To evaluate in patients with severe PR--anticipated to require future pulmonary valve replacement--the feasibility and safety of pre-stenting dilated non-stenotic patched conduit-free right ventricular outflow tracts before excessive dilation occurs, followed by percutaneous pulmonary valve implantation (PPVI). Twenty seven patients were evaluated, but only 23 were deemed suitable based on the presence of an adequate retention zone ≤ 24 mm defined by semi-compliant balloon interrogation of the RVOT. A 2 step procedure was performed: first the landing zone was prepared by deploying a bare stent, followed 2 months later by valve implantation. RVOT pre-stenting with an open cell bare metal stent (Andrastent XXL range) was performed at a median age of 13.0 years (range: 6.0-44.9) with a median weight of 44.3 kg (range: 20.0-88.0). Ninety six percent (22/23) of patients proceeded to PPVI a median of 2.4 months (range: 1.4-3.4) after initial pre-stent placement. Twenty one Melody valves and one 26 mm Edwards SAPIEN™ valve were implanted. Complications consisted of embolization of prestent (n = 1), scrunching (n = 4) and mild stent dislocation (n = 2). During follow-up, no stent fractures were observed and right ventricular dimensions decreased significantly. Post-surgical conduit-free non-stenotic RVOT with free pulmonary regurgitation can be treated percutaneously with a valved stent if anatomical (predominantly size) criteria are met. In experienced hands, the technique is feasible with low morbidity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Randomized trial in malignant biliary obstruction: Plastic vs partially covered metal stents

    PubMed Central

    Moses, Peter L; AlNaamani, Khalid M; Barkun, Alan N; Gordon, Stuart R; Mitty, Roger D; Branch, M Stanley; Kowalski, Thomas E; Martel, Myriam; Adam, Viviane

    2013-01-01

    AIM: To compare efficacy and complications of partially covered self-expandable metal stent (pcSEMS) to plastic stent (PS) in patients treated for malignant, infrahilar biliary obstruction. METHODS: Multicenter prospective randomized clinical trial with treatment allocation to a pcWallstent® (SEMS) or a 10 French PS. Palliative patients aged ≥ 18, for infrahilar malignant biliary obstruction and a Karnofsky performance scale index > 60% from 6 participating North American university centers. Primary endpoint was time to stent failure, with secondary outcomes of death, adverse events, Karnofsky performance score and short-form-36 scale administered on a three-monthly basis for up to 2 years. Survival analyses were performed for stent failure and death, with Cox proportional hazards regression models to determine significant predictive characteristics. RESULTS: Eighty-five patients were accrued over 37 mo, 42 were randomized to the SEMS group and 83 patients were available for analyses. Time to stent failure was 385.3 ± 52.5 d in the SEMS and 153.3 ± 19.8 d in the PS group, P = 0.006. Time to death did not differ between groups (192.3 ± 23.4 d for SEMS vs 211.5 ± 28.0 d for PS, P = 0.70). The only significant predictor was treatment allocation, relating to the time to stent failure (P = 0.01). Amongst other measured outcomes, only cholangitis differed, being more common in the PS group (4.9% vs 24.5%, P = 0.029). The small number of patients in follow-up limits longitudinal assessments of performance and quality of life. From an initially planned 120 patients, only 85 patients were recruited. CONCLUSION: Partially covered SEMS result in a longer duration till stent failure without increased complication rates, yet without accompanying measurable benefits in survival, performance, or quality of life. PMID:24379581

  6. Initial experience with the E-ventus® stent-graft for endovascular treatment of visceral artery aneurysms.

    PubMed

    Anton, Susanne; Stahlberg, Erik; Horn, Marco; Wiedner, Marcus; Kleemann, Markus; Barkhausen, Joerg; Goltz, Jan P

    2018-04-01

    To evaluate the safety and efficacy of a novel balloon-expandable stent-graft for endovascular treatment of visceral artery aneurysms (VAA). Between 9/2014 and 1/2017 seven patients (69±15 years) with true (N.=4) and false (N.=3) VAAs were treated by implantation of balloon-expandable stent-grafts (E-ventus®, Jotec, Hechingen, Germany) using a transfemoral (N.=2) or transbrachial (N.=5) vascular access. The stent-graft was placed without prior passing of the landing zone with a sheath. In 3 of 7 patients (42.9%) additional coil or plug embolization was performed to prevent retrograde VAA perfusion. Endpoints were technical success (defined as delivery and implantation of the stent-graft in the intended position with complete exclusion of the VAA), peri-procedural complications and patency. Mean diameters of true VAAs (splenic artery: N.=2, common hepatic artery: N.=1, celiac trunk: N.=1) were 26±9 and of false (common hepatic artery: N.=2, gastroduodenal artery: N.=1) 29±14 mm. False aneurysms presented as emergencies with active bleeding. Technical success was 100%. One peri-procedural complication was noted: pseudoaneurysm of the accessed brachial artery. After a mean follow-up of 187 days 6/7 stent-grafts (85.7%) were patent. One patient (fVAA) died two days after the emergency procedure owing to multi-organ failure which was assessed to be non-procedure-related. Another patient (fVAA) died 7 months from the procedure owing to cancer. Endovascular treatment of true and false visceral artery aneurysms by use of the E-ventus® stent-graft is safe and effective. Flexibility of the stent-graft and shaft allows for implantation without passing the lesion with a sheath, enabling treatment of distal as well as complex visceral lesions. Long-term results regarding patency in a larger patient cohort are needed to confirm these findings.

  7. Expandable stents.

    PubMed

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation tissue is less likely to occur in areas of established scar than in areas of acute inflammation. In circumstances in which it is essential that a stent remain only temporarily, an expandable stent should not be inserted in favor of a silicone stent, which can be removed. In the future, expandable stents may have silicone coverings or may be constructed of materials that facilitate removal. Until that time, expandable stents should be considered permanent and nonremovable. Subtle differences exist among the available stents. Standard is low-profile expandable construction from wire mesh. A relatively minor difference is the slightly wider expansibility of the Gianturco stent, a quality that makes it the best suited of the three stents for lesions that involve tracheomalacia. Perhaps the only major difference between the Wallstent and the Gianturco and Palmaz stents is its better ability to conform to tortuous lesions. In an acutely angled stricture, a Wallstent offers a better opportunity for successful placement than other stents. The filamentous meshwork of the Wallstent allows it to bend and conform better to distorted airways. The Gianturco and Palmaz stents have little longitudinal elasticity, which makes them less effective in a tortuous or highly angulated airway stenosis. Expandable stents have demonstrated their efficacy and exposed their limitations in the treatment of airway stenoses. Refinements in design should help to lessen specific disadvantages and problems. Covered expandable stents, a realistic prospect, have specific advantages over standard expandable stents; they will be removable and prevent tumor ingrowth. Current investigative work with such prostheses for the vascular system may provide the foundation for their investigative use in the airway. In essence, two categories of expandable stents are evolving, covered and uncovered, each having unique features adaptable to the specific clinical needs.

  8. Improved biocompatibility of poly(lactic-co-glycolic acid) orv and poly-L-lactic acid blended with nanoparticulate amorphous calcium phosphate in vascular stent applications.

    PubMed

    Zheng, Xiaoxin; Wang, Yujue; Lan, Zhiyuan; Lyu, Yongnan; Feng, Gaoke; Zhang, Yipei; Tagusari, Shizu; Kislauskis, Edward; Robich, Michael P; McCarthy, Stephen; Sellke, Frank W; Laham, Roger; Jiang, Xuejun; Gu, Wei Wang; Wu, Tim

    2014-06-01

    Biodegradable polymers used as vascular stent coatings and stent platforms encounter a major challenge: biocompatibility in vivo, which plays an important role in in-stent restenosis (ISR). Co-formulating amorphous calcium phosphate (ACP) into poly(lactic-co-glycolic acid) (PLGA) or poly-L-lactic acid (PLLA) was investigated to address the issue. For stent coating applications, metal stents were coated with polyethylene-co-vinyl acetate/poly-n-butyl methacrylate (PEVA/PBMA), PLGA or PLGA/ACP composites, and implanted into rat aortas for one and three months. Comparing with both PEVA/PBMA and PLGA groups after one month, the results showed that stents coated with PLGA/ACP had significantly reduced restenosis (PLGA/ACP vs. PEVA/PBMA vs. PLGA: 21.24 +/- 2.59% vs. 27.54 +/- 1.19% vs. 32.12 +/- 3.93%, P < 0.05), reduced inflammation (1.25 +/- 0.35 vs. 1.77 +/- 0.38 vs. 2.30 +/- 0.21, P < 0.05) and increased speed of re-endothelialization (1.78 +/- 0.46 vs. 1.17 +/- 0.18 vs. 1.20 +/- 0.18, P < 0.05). After three months, the PLGA/ACP group still displayed lower inflammation score (1.33 +/- 0.33 vs. 2.27 +/- 0.55, P < 0.05) and higher endothelial scores (2.33 +/- 0.33 vs. 1.20 +/- 0.18, P < 0.05) as compared with the PEVA/PBMA group. Moreover, for stent platform applications, PLLA/ACP stent tube significantly reduced the inflammatory cells infiltration in the vessel walls of rabbit iliac arteries relative to their PLLA cohort (NF-kappaB-positive cells: 23.31 +/- 2.33/mm2 vs. 9.34 +/- 1.35/mm2, P < 0.05). No systemic biochemical or pathological evidence of toxicity was found in either PLGA/ACP or PLLA/ACP. The co-formulation of ACP into PLGA and PLLA resulted in improved biocompatibility without systemic toxicity.

  9. Improvement in conformability of the latest generation of thoracic stent grafts.

    PubMed

    Canaud, Ludovic; Cathala, Philipe; Joyeux, Frédéric; Branchereau, Pascal; Marty-Ané, Charles; Alric, Pierre

    2013-04-01

    Poor aortic arch apposition increases the risk of technical failure after thoracic endovascular repair. The aim of this study was to assess the conformability of the latest generation of thoracic stent grafts in relation to the degree of device oversizing and aortic arch angulation. A benchtop pulsatile flow model was designed to test stent graft anchorage in a 2-cm-long proximal landing zone at varying landing zone angles (from 140° down to 70°) and stent graft oversizing (12%-28%). The experiments were performed using 10 human thoracic cadaveric aortas and four stent grafts: C-TAG, Zenith TX2 Pro-Form, Valiant Captivia, and Relay. Device-wall apposition was measured as a function of landing zone angulation and oversizing during static and dynamic (60 pulses/min, 300/150 mm Hg) tests. The Valiant stent graft remained apposed to the aortic wall at each increment of neck angulation and device oversizing. Lack of apposition of the proximal anchorage segment was observed with the C-TAG above 120° landing zone angulation (1-2 mm) and with the Relay above 110° landing zone angulation (1-4 mm). Lack of "body" apposition (1-4 mm) was first observed with the Zenith Pro-Form stent graft above 110° angulation (P = .001). When the device was not apposed to the aortic wall, an increase in stent graft oversizing significantly (P = .01) decreased device-wall apposition. The requirement for close conformability has influenced the design of next-generation devices. Manufacturers have modified devices and/or their deployment system to specifically address this problem. When compared with the results of our previous experimental test, this study demonstrates that these alterations have resulted in a marked improvement in the performance of commercially available stent graft systems. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  10. The cost-effectiveness of beta-radiation therapy for treatment of in-stent restenosis: an analysis at 290-day follow-up.

    PubMed

    Beusterien, Kathleen M; Plante, Kathryn M; Waksman, Ron; Raizner, Albert E; Annis, Marijke; Goss, Thomas F

    2002-01-01

    We studied the cost-effectiveness of percutaneous coronary intervention (PCI) plus beta-radiation (Radiotherapy) vs. PCI alone for treating in-stent restenosis. We analyzed medical resource data collected at US sites during the Intimal Hyperplasia Inhibition with beta In-stent Trial (INHIBIT) to compare the incremental costs between Radiotherapy and PCI alone for each repeat target lesion revascularization (TLR) avoided. Costs were assigned for cardiac-related medical services using the Medicare payer perspective. Radiotherapy increased initial inpatient costs by US$3360 (P<.001). In the Radiotherapy and PCI alone groups, the mean per-patient rates for TLR were 0.13 vs. 0.30 (P=.001), and mean per-patient total costs were US$19,286 vs. US$18,349 (P<.001), respectively. The incremental cost of Radiotherapy relative to PCI alone was US$5512 per TLR avoided, which compares favorably to the observed mean per-patient cost of treating restenosis (US$16,852). beta-radiation is a cost-effective adjunct to PCI in treating patients with in-stent restenosis.

  11. Covered stent graft for treatment of a pseudoaneurysm and carotid blowout syndrome

    PubMed Central

    Janjua, Nazli; Alkawi, Ammar; Georgiadis, Alexandros L.; Kirmani, Jawad F.; Qureshi, Adnan I.

    2008-01-01

    Background Carotid blowout syndrome with pseudoaneurysm, a rapidly progressive pathology, may present emergently with massive oral hemorrhage. Use of an endograft prosthesis offers a treatment strategy with salvation of the carotid artery. Case History: A 55 year old man with advanced squamous cell carcinoma of the head and neck presented with recurrent transoral hemorrhage, requiring endovascular treatment. Technical Report: Coil embolization was initially performed with little impact on the hemorrhage. A 7 x 40 mm Fluency® Plus covered stent (Bard Peripheral Vascular, Tempe, Arizona, USA) was placed and was supplemented by a second 8 x 40 mm Fluency Plus stent, with resulting cessation of active contrast extravasation. Discussion: The risks and benefits of various treatment options of carotid pseudoaneurysm with blowout are discussed including the use or omission of antiplatelet and anticoagulant regimens, with reference to previously reported cases. Conclusion: Tandem, overlapping covered stent placement in the common carotid artery is feasible and offers a treatment option for carotid blowout syndrome. Risks of aggravation of hemorrhage versus long-term thromboembolic events without antiplatelet therapy must be considered in cases of active ongoing hemorrhage. PMID:22518207

  12. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.

    PubMed

    Kandzari, David E; Mauri, Laura; Koolen, Jacques J; Massaro, Joseph M; Doros, Gheorghe; Garcia-Garcia, Hector M; Bennett, Johan; Roguin, Ariel; Gharib, Elie G; Cutlip, Donald E; Waksman, Ron

    2017-10-21

    The development of coronary drug-eluting stents has included use of new metal alloys, changes in stent architecture, and use of bioresorbable polymers. Whether these advancements improve clinical safety and efficacy has not been shown in previous randomised trials. We aimed to examine the clinical outcomes of a bioresorbable polymer sirolimus-eluting stent compared with a durable polymer everolimus-eluting stent in a broad patient population undergoing percutaneous coronary intervention. BIOFLOW V was an international, randomised trial done in patients undergoing elective and urgent percutaneous coronary intervention in 90 hospitals in 13 countries (Australia, Belgium, Canada, Denmark, Germany, Hungary, Israel, the Netherlands, New Zealand, South Korea, Spain, Switzerland, and the USA). Eligible patients were those aged 18 years or older with ischaemic heart disease undergoing planned stent implantation in de-novo, native coronary lesions. Patients were randomly assigned (2:1) to either an ultrathin strut (60 μm) bioresorbable polymer sirolimus-eluting stent or to a durable polymer everolimus-eluting stent. Randomisation was via a central web-based data capture system (mixed blocks of 3 and 6), and stratified by study site. The primary endpoint was 12-month target lesion failure. The primary non-inferiority comparison combined these data from two additional randomised trials of bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent with Bayesian methods. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02389946. Between May 8, 2015, and March 31, 2016, 4772 patients were recruited into the study. 1334 patients met inclusion criteria and were randomly assigned to treatment with bioresorbable polymer sirolimus-eluting stents (n=884) or durable polymer everolimus-eluting stents (n=450). 52 (6%) of 883 patients in the bioresorbable polymer sirolimus-eluting stent group and 41 (10%) of 427 patients in the durable polymer everolimus-eluting stent group met the 12-month primary endpoint of target lesion failure (95% CI -6·84 to -0·29, p=0·0399), with differences in target vessel myocardial infarction (39 [5%] of 831 patients vs 35 [8%] of 424 patients, p=0·0155). The posterior probability that the bioresorbable polymer sirolimus-eluting stent is non-inferior to the durable polymer everolimus-eluting stent was 100% (Bayesian analysis, difference in target lesion failure frequency -2·6% [95% credible interval -5·5 to 0·1], non-inferiority margin 3·85%, n=2208). The outperformance of the ultrathin, bioresorbable polymer sirolimus-eluting stent over the durable polymer everolimus-eluting stent in a complex patient population undergoing percutaneous coronary intervention suggests a new direction in improving next generation drug-eluting stent technology. BIOTRONIK. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Evaluation of the Anti-migration Effect of Barbed Prostatic Stents: In Vitro Study in Urethra-mimicking Bovine Pericardium Phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Na, Han Kyu, E-mail: hankyu1324@empas.com; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Kim, Jin Hyoung, E-mail: m1fenew@hanmail.net

    2013-02-15

    This study was designed to compare the migration rates of covered stents with eight, four, and zero barbs in urethra-mimicking bovine pericardium models. Three types of polytetrafluoroethylene-covered retrievable self-expandable prostatic stents, with eight, four, and zero barbs, were tested in bovine pericardium models, consisting of normal saline-filled acrylic containers with tubes at both ends and a replica of the human urethra. The barbs were 2 mm in length and projected 60 Degree-Sign toward the urinary bladder. The anti-migration force (AMF) and resistance force against stent removal (RFSR) were measured by an automatic push-pull gauge system at a fixed rate (2more » mm/s). Significant differences in AMF among the three stent types were detected (P < 0.001). Median AMF was far greater for eight-barbed than for four-barbed stents (11.96 vs. 7.55 N, P = 0.003). For stent removal, the difference between 4- and 8-barbed stents were not significant in median static (5.54 vs. 6.08 N, P = 0.15) or sliding (prostatic urethra, 5.32 vs. 5.59 N, P = 0.65; membranous urethra, 7.78 vs. 8.57 N, P = 0.364) RFSR. No perforations or scratched traces were observed during removal of these stents. The inclusion of eight barbs projecting 60 Degree-Sign toward the urinary bladder were not only effective against stent migration in this model but suggests that these stents may be suitable for the treatment of prostatic urethral strictures without severely irritating the tissue. However, whether these results translate into living urethral tissue is unclear, necessitating further studies.« less

  14. Rationale and design of the Patient Related OuTcomes with Endeavor versus Cypher stenting Trial (PROTECT): randomized controlled trial comparing the incidence of stent thrombosis and clinical events after sirolimus or zotarolimus drug-eluting stent implantation.

    PubMed

    Camenzind, Edoardo; Wijns, William; Mauri, Laura; Boersma, Eric; Parikh, Keyur; Kurowski, Volkhard; Gao, Runlin; Bode, Christoph; Greenwood, John P; Gershlick, Anthony; O'Neill, William; Serruys, Patrick W; Jorissen, Brenda; Steg, P Gabriel

    2009-12-01

    Drug-eluting stents (DES) reduce restenosis rates compared to bare-metal stents. Most trials using DES enrolled selected patient and lesion subtypes, and primary endpoint focused on angiographic metrics or relatively short-term outcomes. When DES are used in broader types of lesions and patients, important differences may emerge in long-term outcomes between stent types, particularly the incidence of late stent thrombosis. PROTECT is a randomized, open-label trial comparing the long-term safety of the zotarolimus-eluting stent and the sirolimus-eluting stent. The trial has enrolled 8,800 patients representative of those seen in routine clinical practice, undergoing elective, unplanned, or emergency procedures in native coronary arteries in 196 centers in 36 countries. Indications for the procedure and selection of target vessel and lesion characteristics were at the operator's discretion. Procedures could be staged, but no more than 4 target lesions could be treated per patient. Duration of dual antiplatelet therapy was prespecified to achieve similar lengths of treatment in both study arms. The shortest predefined duration was 3 months, as per the manufacturer's instructions. The primary outcome measure is the composite rate of definite and probable stent thrombosis at 3 years, centrally adjudicated using Academic Research Consortium definitions. The main secondary end points are 3-year all-cause mortality, cardiac death, large nonfatal myocardial infarction, and all myocardial infarctions. This large, international, randomized, controlled trial will provide important information on comparative rates of stent thrombosis between 2 different DES systems and safety as assessed by patient-relevant long-term clinical outcomes.

  15. A randomized controlled trial of a middle meatal silastic stent for reducing adhesions and middle turbinate lateralization following endoscopic sinus surgery.

    PubMed

    Chan, Chun L; Elmiyeh, Behrad; Woods, Charmaine; Ullah, Shahid; Gunawardena, Indunil; Carney, A Simon; Ooi, Eng H

    2015-06-01

    Endoscopic sinus surgery (ESS) is indicated for patients with recalcitrant chronic rhinosinusitis symptoms. However, surgical revision can be required because of adhesion formation and middle turbinate lateralization. We investigate the efficacy of a middle meatal silastic stent in reducing these complications after ESS. Thirty-six patients were randomized to receive a silastic stent in the middle meatus unilaterally after ESS. The surgeon was blinded to the side receiving the stent until completion of the ESS. The contralateral side, with no stent, was the control side. Patients completed a 7-day, postoperative, visual analog scale symptom diary and were blinded to the stent side until its removal at the first postoperative visit. Patients were followed up after 2, 8, and 24 weeks. Endoscopic video of the sinus cavities were recorded at all visits and 2 blinded, independent ear/nose/throat (ENT) surgeons assessed the videos using a modified Lund-Kennedy scoring system. Thirty-five of 36 patients completed 6-months' follow-up. Middle turbinate lateralization was observed in 13 sides without a stent vs 1 side with a stent. There was a significant reduction in adhesions at weeks 2 and 8 (p < 0.001) and crusting (p < 0.01) in the stent side compared to control. Video scores at 6 months after surgery for stent and control sides remained unchanged from the 8-week visit. There was no difference between sides for symptom scores, edema, or nasal discharge. Middle meatal silastic stents are well tolerated by patients and effective in reducing middle turbinate lateralization, adhesions, and crusting postoperatively in ESS. © 2015 ARS-AAOA, LLC.

  16. [The implantation of elastic metal endoprostheses in tracheal stenosis and tracheomalacia. The initial results with 4 patients].

    PubMed

    Berger, H; Gärtner, C; Kohz, P; Stäbler, A; Dienemann, H; Wilmes, E

    1993-07-01

    Narrowing of the trachea due to tracheomalacia or compression can lead to life-threatening asphyxia and may require tracheotomy with intubation or endoscopic introduction of a stent. The use of a self-expanding elastic metal prosthesis in 4 patients with airway obstruction has proved a satisfactory alternative to conventional plastic prostheses, both in the acute phase and over a long period of time. After 4 weeks total epithelium cover of the stent could be demonstrated; biopsies after 3 and 4 months showed differentiation into respiratory ciliated epithelium. Patient acceptance was excellent since there was no sensation of a foreign body, retention of secretions or cough. The physical properties of the wall stent made it a suitable mechanical replacement for an unstable or narrowed trachea during the period of observation.

  17. Numerical analysis of urine flow through the side holes of a double J stent in a ureteral stenosis.

    PubMed

    Kim, Hyoung-Ho; Choi, Young Ho; Lee, Seung Bae; Baba, Yasutaka; Kim, Kyung-Wuk; Suh, Sang-Ho

    2017-07-20

    Ureteral stenosis presents with a narrowing in the ureter, due to an intrinsic or extrinsic ureteral disease, such as ureter cancer or retroperitoneal fibrosis. The placement of a double J stent in the upper urinary system is one of the most common treatments of ureteral stenosis, along with the insertion of a percutaneous nephrostomy tube into the renal pelvis. The effect that the side holes in a double J stent have on urine flow has been evaluated in a few studies using straight ureter models. In this study, urine flow through a double J stent's side holes was analyzed in curved ureter models, which were based on human anatomy. In ureteral stenosis, especially in severe ureteral stenosis, a stent with side holes had a positive effect on the luminal and total flow rates, compared with the rates for a stent without side holes. The more side holes a stent has, the greater the luminal and total flow rates. However, the angular positions of the side holes did not affect flow rate. In conclusion, the side holes in a double J stent had a positive effect on ureteral stenosis, and the effect became greater as the ureteral stenosis became more severe.

  18. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    NASA Astrophysics Data System (ADS)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  19. An investigation into the effect of surface roughness of stainless steel on human umbilical vein endothelial cell gene expression.

    PubMed

    McLucas, E; Moran, M T; Rochev, Y; Carroll, W M; Smith, T J

    2006-01-01

    The surface properties of vascular devices dictate the initial postimplantation reactions that occur and thus the efficacy of the implantation procedure. Over the last number of years, a number of different stent designs have emerged and stents are generally polished to a mirror finish during the manufacturing procedure. This study sought to investigate the effect of stainless steel surface roughness on endothelial cell gene expression using an appropriate cell culture in vitro assay system. Stainless steel discs were roughened by shot blasting or polished by mechanical polishing. The surface roughness of the treated and untreated discs was determined by atomic force microscopy (AFM). Cells were seeded on collagen type 1 gels and left to attach for 24 h. Stainless steel discs of varying roughness were then placed in contact with the cells and incubated for 24 h. RNA extractions and quantitative real-time reverse transcriptase-polymerase chain reaction (RT-PCR) was then performed to determine the expression levels of candidate genes in the treated cells compared to suitable control cells. E-selectin and vascular cellular adhesion molecule (VCAM-1) were found to be significantly up-regulated in cells incubated with polished and roughened samples, indicating endothelial cell activation and inflammation. This study indicates that the surface roughness of stainless steel is an important surface property in the development of vascular stents.

  20. Advantages of novel BioMimeTM Sirolimus Eluting Coronary Stent system. Moving towards biomimicry.

    PubMed

    Upendra, K; Sanjeev, B

    2012-02-01

    Since the first reported use of percutaneous transluminal coronary angioplasty (PTCA), advancements in interventional cardiology arena have been fast paced. Within the last ten years, these developments have been exponential. Developers & clinicians are fast adapting from the learning curve awarded by the time course of DES evolution. In that light BioMimeTM Sirolimus Eluting Coronary Stent comes as a fresh thought in taking stents towards a biomimicry concept. The stent is built on an ultra-low strut thickness (65 µm) cobalt chromium stent platform, using an intelligent hybrid of close and open cells allowing for morphology mediated expansion, employs a well known anti-proliferative - Sirolimus that elutes from a biodegradable co-polymer formulation in 30 days and ensures high coating integrity and low coating thickness of 2 µm. The resultant stent demonstrates almost 100% endothelialization at 30 days in preclinical model and zero percent MACE >18 months in the primary efficacy and safety clinical study.

  1. Semi-Automatic Electronic Stent Register: a novel approach to preventing ureteric stents lost to follow up.

    PubMed

    Macneil, James W H; Michail, Peter; Patel, Manish I; Ashbourne, Julie; Bariol, Simon V; Ende, David A; Hossack, Tania A; Lau, Howard; Wang, Audrey C; Brooks, Andrew J

    2017-10-01

    Ureteric stents are indispensable tools in modern urology; however, the risk of them not being followed-up once inserted poses medical and medico-legal risks. Stent registers are a common solution to mitigate this risk; however, manual registers are logistically challenging, especially for busy units. Western Sydney Local Health District developed a novel Semi-Automatic Electronic Stent Register (SAESR) utilizing billing information to track stent insertions. To determine the utility of this system, an audit was conducted comparing the 6 months before the introduction of the register to the first 6 months of the register. In the first 6 months of the register, 457 stents were inserted. At the time of writing, two of these are severely delayed for removal, representing a rate of 0.4%. In the 6 months immediately preceding the introduction of the register, 497 stents were inserted, and six were either missed completely or severely delayed in their removal, representing a rate of 1.2%. A non-inferiority analysis found this to be no worse than the results achieved before the introduction of the register. The SAESR allowed us to improve upon our better than expected rate of stents lost to follow up or severely delayed. We demonstrated non-inferiority in the rate of lost or severely delayed stents, and a number of other advantages including savings in personnel costs. The semi-automatic register represents an effective way of reducing the risk associated with a common urological procedure. We believe that this methodology could be implemented elsewhere. © 2017 Royal Australasian College of Surgeons.

  2. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    PubMed

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  3. Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique.

    PubMed

    Nevzati, Edin; Rey, Jeannine; Coluccia, Daniel; D'Alonzo, Donato; Grüter, Basil; Remonda, Luca; Fandino, Javier; Marbacher, Serge

    2017-10-01

    The steady progess in the armamentarium of techniques available for endovascular treatment of intracranial aneurysms requires affordable and reproducable experimental animal models to test novel embolization materials such as stents and flow diverters. The aim of the present project was to design a safe, fast, and standardized surgical technique for stent assisted embolization of saccular aneurysms in a rat animal model. Saccular aneurysms were created from an arterial graft from the descending aorta.The aneurysms were microsurgically transplanted through end-to-side anastomosis to the infrarenal abdominal aorta of a syngenic male Wistar rat weighing >500 g. Following aneurysm anastomosis, aneurysm embolization was performed using balloon expandable magnesium stents (2.5 mm x 6 mm). The stent system was retrograde introduced from the lower abdominal aorta using a modified Seldinger technique. Following a pilot series of 6 animals, a total of 67 rats were operated according to established standard operating procedures. Mean surgery time, mean anastomosis time, and mean suturing time of the artery puncture site were 167 ± 22 min, 26 ± 6 min and 11 ± 5 min, respectively. The mortality rate was 6% (n=4). The morbidity rate was 7.5% (n=5), and in-stent thrombosis was found in 4 cases (n=2 early, n=2 late in stent thrombosis). The results demonstrate the feasibility of standardized stent occlusion of saccular sidewall aneurysms in rats - with low rates of morbidity and mortality. This stent embolization procedure combines the opportunity to study novel concepts of stent or flow diverter based devices as well as the molecular aspects of healing.

  4. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, themore » wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.« less

  5. Stenting in Malignant Biliary Obstruction.

    PubMed

    Almadi, Majid A; Barkun, Jeffrey S; Barkun, Alan N

    2015-10-01

    Decompression of the biliary system in patients with malignant biliary obstruction has been widely accepted and implemented as part of the care. Despite a wealth of literature, there remains a significant amount of uncertainty as to which approach would be most appropriate in different clinical settings. This review covers stenting of the biliary system in cases of resectable or palliative malignant biliary obstruction, potential candidates for biliary drainage, technical aspects of the procedure, as well as management of biliary stent dysfunction. Furthermore, periprocedural considerations including proper mapping of the location of obstruction and the use of antibiotics are addressed. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    PubMed

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  7. Comparative effectiveness of commonly used devices for carotid artery stenting: an NCDR Analysis (National Cardiovascular Data Registry).

    PubMed

    Giri, Jay; Kennedy, Kevin F; Weinberg, Ido; Hawkins, Beau M; Press, Marcella Calfon; Drachman, Douglas; McCormick, Daniel J; Aronow, Herbert D; White, Christopher J; Rosenfield, Kenneth; Yeh, Robert W

    2014-02-01

    This study sought to characterize usage and outcomes of carotid stenting platforms. A variety of stents and embolic protection devices (EPDs) are used for carotid artery stenting. Little is known about current usage patterns and differences in outcomes with these devices. We analyzed 12,135 consecutive carotid stent procedures in the NCDR (National Cardiovascular Data Registry) CARE (Carotid Artery Revascularization and Endarterectomy) registry performed between January 1, 2007 and March 31, 2012. We compared baseline characteristics and crude and multivariable-adjusted rates of in-hospital combined death/stroke among patients treated with Acculink/Accunet (Abbott Laboratories, Abbott Park, Illinois), Xact/Emboshield (Abbott), and Precise/Angioguard (Cordis Corporation, Bridgewater, New Jersey) stent/EPD combinations. In 78.2% of cases, stents were used in conjunction with their specific, corresponding U.S. Food and Drug Administration-approved EPD. The Acculink/Accunet (n = 2,617, 21.6%), Xact/Emboshield (n = 3,507, 28.9%), and Precise/Angioguard (n = 2,696, 22.2%) stent/EPD combinations were used in 72.7% of all cases. The Protégé/SpiderFx (ev3 Endovascular Inc., Plymouth, Minnesota) (n = 453, 3.7%) and Wallstent/Filterwire (Boston Scientific, Natick, Massachusetts) (n = 213, 1.8%) devices were used in a minority of cases. In unadjusted analyses, the Precise/Angioguard system was associated with higher rates of the primary outcome than were the Acculink/Accunet (2.5% vs. 1.8%; p = 0.058) and Xact/Emboshield (2.5% vs. 1.9%; p = 0.14) systems that were not statistically different. In adjusted analyses, differences between Precise/Angioguard and Accunet/Acculink (odds ratio [OR]: 1.48, 95% confidence interval [CI]: 0.89 to 2.47; p = 0.065), Precise/Angioguard and Xact/Emboshield (OR: 1.16, 95% CI: 0.77 to 1.76; p = 0.38), and Xact/Emboshield and Accunet/Acculink (OR: 1.28, 95% CI: 0.82 to 1.97; p = 0.18) remained nonsignificant. In modern U.S. practice, the Acculink/Accunet, Xact/Emboshield, and Precise/Angioguard carotid stenting systems are used in most cases and are associated with similarly low rates of adverse events. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Impact of nitinol stent surface processing on in-vivo nickel release and biological response.

    PubMed

    Nagaraja, Srinidhi; Sullivan, Stacey J L; Stafford, Philip R; Lucas, Anne D; Malkin, Elon

    2018-05-01

    Although nitinol is widely used in percutaneous cardiovascular interventions, a causal relationship between nickel released from implanted cardiovascular devices and adverse systemic or local biological responses has not been established. The objective of this study was to investigate the relationship between nitinol surface processing, in-vivo nickel release, and biocompatibility. Nitinol stents manufactured using select surface treatments were implanted into the iliac arteries of minipigs for 6 months. Clinical chemistry profile, complete blood count, serum and urine nickel analyses were performed periodically during the implantation period. After explant, stented arteries were either digested and analyzed for local nickel concentration or fixed and sectioned for histopathological analysis of stenosis and inflammation within the artery. The results indicated that markers for liver and kidney function were not different than baseline values throughout 180 days of implantation regardless of surface finish. In addition, white blood cell, red blood cell, and platelet counts were similar to baseline values for all surface finishes. Systemic nickel concentrations in serum and urine were not significantly different between processing groups and comparable to baseline values during 180 days of implantation. However, stents with non-optimized surface finishing had significantly greater nickel levels in the surrounding artery compared to polished stents. These stents had increased stenosis with potential for local inflammation compared to polished stents. These findings demonstrate that proper polishing of nitinol surfaces can reduce in-vivo nickel release locally, which may aid in minimizing adverse inflammatory reactions and restenosis. Nitinol is a commonly used material in cardiovascular medical devices. However, relationships between nitinol surface finishing, in-vivo metal ion release, and adverse biological responses have yet to be established. We addressed this knowledge gap by implanting single and overlapped nitinol stents with different surface finishes to assess systemic impact on minipigs (i.e. serum and urine nickel levels, liver and kidney function, immune and blood count) over the 6 month implantation period. In addition, nickel levels and histopathology in stented arteries were analyzed on explant to determine relationships between surface processing and local adverse tissue reactions. The findings presented here highlight the importance of surface processing on in-vivo nickel release and subsequent impact on local biological response for nitinol implants. Published by Elsevier Ltd.

  9. Intralacrimal migration of Masterka® stents.

    PubMed

    Fayet, B; Racy, E; Katowitz, W R; Katowitz, J A; Ruban, J-M; Brémond-Gignac, D

    2018-03-01

    Tearing and conjunctivitis in children are commonly due to lacrimal drainage system obstruction. Congenital nasolacrimal obstruction is a common pathology treated by probing with or without silicone stent insertion, depending upon the age of the child. The silicone stent is self-retaining and placed for at least one month. Masterka ® is a recent version of Monoka ® , which may lead to the same surgical complications, such as intralacrimal migration. The medical records of two patients surgically treated with the Masterka ® probe for nasolacrimal duct obstruction, who developed intralacrimal migration of the stent, were retrospectively reviewed and analyzed. A 41-month-old child and an 18-month-old child presented with disappearance of the silicone tube after 7 days and 2 years respectively. In the first case, the tube migrated completely within the lacrimal system and became externalized through the nose at 2 years, while in the second case, the Masterka ® was retrieved through a canalicular approach. In both cases, infants had no further tearing. The frequency self-retaining stent disappearance is estimated at 15%. Among these cases, intralacrimal migration is only reported in 0.5% of cases. To prevent intralacrimal migration, the surgical technique must follow a certain number of rules. Management, based on residual epiphora, is discussed. Prevention of intralacrimal migration of self-retaining stents involves a rigorous analysis of the relationship between the meatus and the fixation head at the time of placement. After lacrimal intubation, scheduled monitoring is necessary to screen for stent disappearance. Management is based on clinical findings, anterior rhinoscopy and even exploratory canaliculotomy. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  10. Flow-independent dynamics in aneurysms: intra-aneurysm pressure measurements following complete flow cessation in internal carotid artery aneurysms.

    PubMed

    Qureshi, Adnan I; Qureshi, Mushtaq H; Mohindroo, Tanya; Khan, Asif A; Dingmann, Kayla; Sherr, Gregory T; Suri, M Fareed K

    2014-12-01

    To determine if complete flow obliteration by covered stents reduces intra-aneurysm pressures in internal carotid artery (ICA) aneurysms. A single lumen microcatheter was placed into the aneurysm sac prior to covered stent deployment in 3 patients and connected to a pressure monitoring system. The intra-aneurysm pressure was continuously monitored, and readings were recorded prior to and immediately after stent deployment and at 5-minute intervals up to 20 minutes after stent placement. Complete occlusion of flow into the aneurysms was confirmed by carotid angiography. There was no change in mean pressure within the aneurysm before and immediately after stent placement (80 mmHg) in any patient, nor was there a change in waveform of the intra-aneurysm pressure recording. The average of intra-aneurysm pressures among the 3 patients was higher (99 mmHg) at 10 and 15 minutes after stent placement. In 2 patients, the microcatheter was retracted into the parent arterial lumen; no difference in pressure was noted. Our observations suggest no change in the pressures within the aneurysm after complete flow cessation (flow-independent). These findings may assist clinicians in better understanding aneurysm hemodynamics and rupture after covered stent deployment.

  11. First Approval of Improved Medical Device Conditional on Use-Result Survey in Japan - Regulatory Review of Polymer-Free Drug-Coated BioFreedom Coronary Stent.

    PubMed

    Konishi, Akihide; Ho, Mami; Shirai, Yuko; Shirato, Haruki

    2018-05-25

    A prospective randomized clinical trial showed that the BioFreedom stent (Biosensors International), which is a polymer-free and carrier-free drug-coated stent, was significantly superior to a bare-metal stent (BMS) in patients at high bleeding risk who were receiving a 1-month course of dual antiplatelet therapy (DAPT). However, the stent thrombosis rate (2.01% for BioFreedom vs. 2.20% for BMS) was 4-6-fold higher than that of approved drug-eluting stents based on real-world data in Japan. Furthermore, the frequency of stent thrombosis at more than 1 month with the BioFreedom stent was slightly higher than that at less than 1 month. This result suggested that it would not be acceptable to stop DAPT universally at 1 month. Thus, the target patients for the BioFreedom stent are unspecified patients at high bleeding risk needing to continue DAPT for as long as necessary in Japan. Therefore, based on the pre- and post-marketing balance of medical devices regulations, regulatory approval was given for unspecified patients conditionally upon real-world data collection of 2,000 patients with a Use-Results Survey, instead of conducting additional pre-marketing clinical trial(s). The Use-Results Survey System is part of a strategy to expedite patients' access to innovative medical devices and to accelerate the development of medical devices.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Wei-Zhong, E-mail: xmjbq007@163.com; Yang, Zheng-Qiang, E-mail: ntdoctoryang@hotmail.com; Liu, Sheng, E-mail: liusheng1137@sina.com

    PurposeTo evaluate the clinical effectiveness of a newly designed stent for the treatment of malignant distal duodenal stenosis.MethodsFrom March 2011 to May 2013, six patients with malignant duodenal stenosis underwent fluoroscopically guided placement of the new duodenal stent consisting of braided, nested stent wires, and a delivery system with a metallic mesh inner layer. Primary diseases were pancreatic cancer in three patients, gastric cancer in two patients, and endometrial stromal sarcoma in one patient. Duodenal obstructions were located in the horizontal part in two patients, the ascending part in two patients, and the duodenojejunal flexure in two patients. Technical success,more » defined as the successful stent deployment, clinical symptoms before and after the procedure, and complications were evaluated.ResultsTechnical success was achieved in all patients. No major complications were observed. Before treatment, two patients could not take any food and the gastric outlet obstruction scoring system (GOOSS) score was 0; the other four patients could take only liquids orally (GOOSS score = 1). After treatment, five patients could take soft food (GOOSS score = 2) and one patient could take a full diet (GOOSS score = 3). The mean duration of primary stent patency was 115.7 days.ConclusionsThe newly designed stent is associated with a high degree of technical success and good clinical outcome and may be clinically effective in the management of malignant distal duodenal obstruction.« less

  13. Proximal protection with the Gore PAES can reduce DWI lesion size in high-grade stenosis during carotid stenting.

    PubMed

    Grunwald, Iris Quasar; Reith, Wolfgang; Kühn, Anna Luisa; Balami, Joyce S; Karp, Kerstin; Fassbender, Klaus; Walter, Silke; Papanagiotou, Panagiotis; Krick, Christoph

    2014-06-01

    The aim was to determine the incidence of new ischaemic lesions on diffusion-weighted MR imaging (DWI) in a non-randomised cohort of patients after protected and unprotected carotid artery stent placement using the Parodi Anti-Emboli System (PAES). A retrospective review was conducted on 269 patients who received DWI prior to, and 24-72 hours after, stent placement. All patients were enrolled in one centre. Forty patients stented with the PAES device were matched with 229 patients stented without protection (control group). New diffusion restriction on DWI was detected in 25.8% (PAES) versus 32.3% (control group); p=0.64. On average there were 0.7 lesions (PAES) versus 0.8 lesions (control group) per patient. The area of lesions was 1.7 (PAES) versus 5.6 mm2. In a subanalysis of patients (32 PAES, 148 non-protected) with >80% stenosis, the area of restricted diffusion was less when proximal protection was used (p<0.05). The number and area of DWI lesions did not differ on the contralateral, non-stented side. When the PAES system was used, patients were more likely not to have any lesion at all (p=0.028). In high-grade stenosis, the use of the Gore PAES device significantly reduced the area of new DWI lesions and patients were more likely not to have any new DWI lesion at all.

  14. Comparison of ADM and Connective Tissue Graft as the Membrane in Class II Furcation Defect Regeneration: A Randomized Clinical Trial

    PubMed Central

    Esfahanian, Vahid; Farhad, Shirin; Sadighi Shamami, Mehrnaz

    2014-01-01

    Background and aims. Furcally-involved teeth present unique challenges to the success of periodontal therapy and influence treatment outcomes. This study aimed to assess to compare use of ADM and connective tissue membrane in class II furcation defect regeneration. Materials and methods. 10 patient with 2 bilaterally class II furcation defects in first and/or second maxilla or man-dibular molar without interproximal furcation involvement, were selected. Four weeks after initial phase of treatment, before and thorough the surgery pocket depth (PD), clinical attachment level to stent (CAL-S), free gingival margin to stent(FGM-S) , crestal bone to stent (Crest-S), horizontal defect depth to stent (HDD-S) and vertical defect depth to stent (VDD-S) and crestal bone to defect depth measured from stent margin. Thereafter, one side randomly treated using connective tissue and DFDBA (study group) and opposite side received ADM and DFDBA (control group). After 6 months, soft and hard tissue parameters measured again in re-entry. Results. Both groups presented improvements after therapies (P & 0.05). No inter-group differences were seen in PD re-duction (P = 0.275), CAL gain (P = 0.156), free gingival margin (P = 0.146), crest of the bone (P = 0.248), reduction in horizontal defects depth (P = 0.139) and reduction in vertical defects depth (P = 0.149). Conclusion. Both treatments modalities have potential of regeneration without any adverse effect on healing process. Connective tissue grafts did not have significant higher bone fill compared to that of ADM. PMID:25093054

  15. Endoscopic Stenting as Bridge to Surgery versus Emergency Resection for Left-Sided Malignant Colorectal Obstruction: An Updated Meta-Analysis

    PubMed Central

    Ceresoli, Marco; Fugazzola, Paola; Ansaloni, Luca

    2017-01-01

    Introduction Emergency resection represents the traditional treatment for left-sided malignant obstruction. However, the placement of self-expanding metallic stents and delayed surgery has been proposed as an alternative approach. The aim of the current meta-analysis was to review the available evidence, with particular interest for the short-term outcomes, including a recent multicentre RCT. Methods We considered randomized controlled trials comparing stenting as a bridge to surgery and emergency surgery for the management of left-sided malignant large bowel obstruction, performing a systematic review in MEDLINE, PubMed database, and the Cochrane libraries. Results We initially identified a total of 2543 studies. After the elimination of duplicates and the screening of titles and abstracts, seven studies, for a total of 448 patients, were considered. The current meta-analysis revealed no difference in the mortality rate between the stent group and the emergency surgery group; the postoperative complication rate (37.84% versus 54.87%, P = 0.02), the stoma rate (28.8% versus 46.02%, P < 0.0001), and the incidence of wound infection (8.11% versus 15.49%, P = 0.01) were reduced after stent as a bridge to surgery. Conclusion Colonic stenting as a bridge to surgery appears to be a safe approach to malignant large bowel obstruction. Possible advantages of this treatment can be identified in a reduced incidence of postoperative complications and a lower stoma rate. Further RCTs considering long-term outcomes and cost-effectiveness analysis are needed. PMID:28761765

  16. Evaluation of Quality of Life Following Placement of Self-Expanding Plastic Stents as a Bridge to Surgery in Patients Receiving Neoadjuvant Therapy for Esophageal Cancer

    PubMed Central

    Cannon, Robert M.; Brown, Russell E.; Ellis, Susan F.; Williams, Sharon; Scoggins, C.R.; Abbas, Abbas E.

    2014-01-01

    Purpose. To determine whether self-expanding plastic stent (SEPS) placement significantly improves quality of life and maintains optimal nutrition while allowing full-dose neoadjuvant therapy (NAT) in patients with esophageal cancer. Patients and Methods. A prospective, dual-institution, single-arm, phase II (http://ClinicalTrials.gov: NCT00727376) evaluation of esophageal cancer patients undergoing NAT prior to resection. All patients had a self-expanding polymer stent placed prior to NAT. The European Organisation for Research and Treatment of Cancer QLQ-C30 and QLQ-OG25, Functional Assessment of Cancer Therapy–Anorexia, and Functional Assessment of Cancer Therapy–General surveys were administered prior to stenting, within 1 week post-stent placement, and at the completion of neoadjuvant therapy. Results. Fifty-two patients were enrolled; 3 (5.8%) had stent migrations requiring replacement. There were no instances of esophageal erosion or perforation. All patients received some form of neoadjuvant therapy. Thirty-six (69%) received chemoradiation; 34 (93%) of these patients received the planned dose of chemotherapy, and 27 (75%) received the full planned dose of radiotherapy. There were 16 (31%) patients receiving chemotherapy alone; 12 (74%) of patients in the chemotherapy-alone group completed the planned dose of therapy. Conclusion. Placement of SEPS appears to provide significant improvement in quality of life related to dysphagia and eating restriction in patients with esophageal cancer undergoing neoadjuvant therapy. Consideration of SEPS instead of percutaneous feeding tube should be initiated as a first line in dysphagia palliation and NAT nutritional support. PMID:24567281

  17. Long-term complications of JJ stent and its management: A 5 years review

    PubMed Central

    Ray, Rajendra Prasad; Mahapatra, Rajkumar Singha; Mondal, Partha Pratim; Pal, Dilip Kumar

    2015-01-01

    Objectives: To assess the long term complications of JJ stent, the management of complications and the role of endoscopic approach to manage these complications. Materials and Methods: Nineteen patients with indwelling JJ stent for a duration of more than 6 months were included in this study. Patients were assessed with X-ray KUB, USG KUB, blood urea, creatinine and DTPA renogram. Data were analyzed by Microsoft excel 2007. Results: Out of 19 patients 12 (63.16%) were male and 7 (36.84%) were female. The mean age was 39.78 ± 13.69 years., Mean duration for which the stent was in situ was 29.56 months. The most common complication was broken stent, in 11 cases (57.89%). Other complications were migration in 5 (26.32%), encrustation in 2 (10.52%) and 1 case of (5.26%) stone formation. Eighteen cases were managed by endoscopic approaches. A total of 22 procedures were performed to treat the complications. Eleven cases were managed by a single procedure and 8 patients required multiple procedures. All were managed successfully with no death reported. Post-operative complications were seen in eight cases (42.11%). Conclusions: JJ stent related long-term complications are not uncommon and are usually seen after 6 months of indwelling time. Endourological procedure should be the initial approach with a high success rate. Coordinated use multimodality and technology helps in management of difficult cases. Open surgery is rarely required. Prevention of the complication by judicious use and early removal is the cornerstone. PMID:25657542

  18. Effects of incomplete stent apposition on the changes in hemodynamics inside a curved and calcified coronary artery

    NASA Astrophysics Data System (ADS)

    Poon, Eric; Ooi, Andrew; Barlis, Peter; Hayat, Umair; Moore, Stephen

    2014-11-01

    Percutaneous coronary intervention (PCI) is the modern gold standard for treatment of coronary artery disease. Stenting (a common PCI procedure) of simple lesion inside a relatively straight segment of coronary artery has proven to be highly successful. However, incomplete stent apposition (ISA) where there is a lack of contact between the stent struts and lumen wall is not uncommon in curved and calcified coronary arteries. Computational fluid dynamics simulations are carried out to study the changes in hemodynamics as a result of ISA inside a curved and calcified coronary artery. For a 3 mm coronary artery, we simulate a resting condition at 80 mL/min and a range of hyperemic conditions with coronary flow reserve in between 1 and 2. The heartbeat is fixed at 75 BPM. Five different curvatures of the coronary artery are considered. Negative effects on hemodynamic variables, such as low wall shear stress (<0.5 Pa); high wall shear stress gradient (>5,000 Pa/m) and oscillation shear index (0 <= OSI <= 0.5), are employed to identify locations with high possibilities of adverse clinical events. This study will lead to better understandings of ISA in curved and calcified coronary arteries and help improve future coronary stent deployment. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).

  19. Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

    PubMed

    Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan

    2006-04-01

    To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

  20. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair.

    PubMed

    Koenrades, Maaike A; Klein, Almar; Leferink, Anne M; Slump, Cornelis H; Geelkerken, Robert H

    2018-04-01

    To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort study (LSPEAS; Trialregister.nl identifier NTR4276). The patients were treated electively using an Anaconda stent-graft with a mean 31% oversizing (range 17-47). According to protocol, participants were to be followed for 2 years, during which 5 noncontrast electrocardiogram-gated computed tomography scans would be conducted. Three patients were eliminated within 30 days (1 withdrew, 1 died, and a third was converted before stent-graft deployment), leaving 15 patients (mean age 72.8±3.7 years; 14 men) for this analysis. Evolution in size and shape (symmetry) of both proximal infrarenal sealing rings were assessed from discharge to 24 months using dedicated postprocessing algorithms. At 24 months, the mean diameters of the first and second ring stents had increased significantly (first ring: 2.2±1.0 mm, p<0.001; second ring: 2.7±1.1 mm, p<0.001). At 6 months, the first and second rings had expanded to a mean 96.6%±2.1% and 94.8%±2.7%, respectively, of their nominal diameter, after which the rings expanded slowly; ring diameters stabilized to near nominal size (first ring, 98.3%±1.1%; second ring, 97.2%±1.4%) at 24 months irrespective of initial oversizing. No type I or III endoleaks or aneurysm-, device-, or procedure-related adverse events were noted in follow-up. The difference in the diametric distances between the peaks and valleys of the saddle-shaped rings was marked at discharge but became smaller after 24 months for both rings (first ring: median 2.0 vs 1.2 mm, p=0.191; second ring: median 2.8 vs 0.8 mm; p=0.013). Irrespective of initial oversizing, the Anaconda proximal sealing rings radially expanded to near nominal size within 6 months after EVAR. Initial oval-shaped rings conformed symmetrically and became nearly circular through 24 months. These findings should be taken into account in planning and follow-up.

  1. Flexible Automation System for Determination of Elemental Composition of Incrustations in Clogged Biliary Endoprostheses Using ICP-MS.

    PubMed

    Fleischer, Heidi; Ramani, Kinjal; Blitti, Koffi; Roddelkopf, Thomas; Warkentin, Mareike; Behrend, Detlef; Thurow, Kerstin

    2018-02-01

    Automation systems are well established in industries and life science laboratories, especially in bioscreening and high-throughput applications. An increasing demand of automation solutions can be seen in the field of analytical measurement in chemical synthesis, quality control, and medical and pharmaceutical fields, as well as research and development. In this study, an automation solution was developed and optimized for the investigation of new biliary endoprostheses (stents), which should reduce clogging after implantation in the human body. The material inside the stents (incrustations) has to be controlled regularly and under identical conditions. The elemental composition is one criterion to be monitored in stent development. The manual procedure was transferred to an automated process including sample preparation, elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS), and data evaluation. Due to safety issues, microwave-assisted acid digestion was executed outside of the automation system. The performance of the automated process was determined and validated. The measurement results and the processing times were compared for both the manual and the automated procedure. Finally, real samples of stent incrustations and pig bile were analyzed using the automation system.

  2. Local sustained delivery of acetylsalicylic acid via hybrid stent with biodegradable nanofibers reduces adhesion of blood cells and promotes reendothelialization of the denuded artery

    PubMed Central

    Lee, Cheng-Hung; Lin, Yu-Huang; Chang, Shang-Hung; Tai, Chun-Der; Liu, Shih-Jung; Chu, Yen; Wang, Chao-Jan; Hsu, Ming-Yi; Chang, Hung; Chang, Gwo-Jyh; Hung, Kuo-Chun; Hsieh, Ming-Jer; Lin, Fen-Chiung; Hsieh, I-Chang; Wen, Ming-Shien; Huang, Yenlin

    2014-01-01

    Incomplete endothelialization, blood cell adhesion to vascular stents, and inflammation of arteries can result in acute stent thromboses. The systemic administration of acetylsalicylic acid decreases endothelial dysfunction, potentially reducing thrombus, enhancing vasodilatation, and inhibiting the progression of atherosclerosis; but, this is weakened by upper gastrointestinal bleeding. This study proposes a hybrid stent with biodegradable nanofibers, for the local, sustained delivery of acetylsalicylic acid to injured artery walls. Biodegradable nanofibers are prepared by first dissolving poly(D,L)-lactide-co-glycolide and acetylsalicylic acid in 1,1,1,3,3,3-hexafluoro-2-propanol. The solution is then electrospun into nanofibrous tubes, which are then mounted onto commercially available bare-metal stents. In vitro release rates of pharmaceuticals from nanofibers are characterized using an elution method, and a highperformance liquid chromatography assay. The experimental results suggest that biodegradable nanofibers release high concentrations of acetylsalicylic acid for three weeks. The in vivo efficacy of local delivery of acetylsalicylic acid in reducing platelet and monocyte adhesion, and the minimum tissue inflammatory reaction caused by the hybrid stents in treating denuded rabbit arteries, are documented. The proposed hybrid stent, with biodegradable acetylsalicylic acid-loaded nanofibers, substantially contributed to local, sustained delivery of drugs to promote re-endothelialization and reduce thrombogenicity in the injured artery. The stents may have potential applications in the local delivery of cardiovascular drugs. Furthermore, the use of hybrid stents with acetylsalicylic acid-loaded nanofibers that have high drug loadings may provide insight into the treatment of patients with high risk of acute stent thromboses. PMID:24421640

  3. A preliminary report on the effects of paclitaxel-impregnated stents on sheep nasal mucosa.

    PubMed

    Herrmann, Brian W; Citardi, Martin J; Vogler, George; Gardner, Laura; Smith, Greg; Javer, Amin R; Burt, Helen M; Jackson, John; Kuhn, Frederick A

    2004-01-01

    Traditional frontal sinus stents serve only as mechanical devices. It has been proposed that stents also may serve as drug-delivery systems for the topical application of drugs that minimize postoperative scarring. Paclitaxel (Taxol), which has recognized antiscarring effects, may be incorporated via a polymeric formulation into standard rubber stents. The impact of topically applied paclitaxel on the morphology of the nasal mucosa is unknown. An adult sheep model was used for this study. A modified rubber T-tube stent (incorporating paclitaxel at varying dosages) was secured to each side of the septum in four animals (eight sides). An unmodified T-tube was placed on each side of one animal, a T-tube with the drug carrier (but no paclitaxel) was placed on each side of the second animal, and T-tubes with varying paclitaxel were placed on each side of the final two animals. After 4 weeks, animals were killed and the nasal mucosa was harvested. The nasal mucosa was sectioned and stained with hematoxylin and eosin. A pathologist then assessed the nasal mucosa for vascular congestion, glandular atrophy, chronic inflammation, mucosal metaplasia, and mucosal ulceration. No consistent histopathological differences were noted in the specimens. All specimens showed varying degrees of vascular congestion, glandular atrophy, chronic inflammation, and mucosal metaplasia; the paclitaxel-impregnated stents were not consistently associated with more severe mucosal injury. Finally, mucosal ulceration was noted to be very rare in all specimens. This preliminary report describes the impact of paclitaxel-impregnated stents on sheep nasal mucosa, which tolerated these stents very well. Because paclitaxel minimizes scarring reactions at very low concentrations, paclitaxel-impregnated stents may prove useful in clinical situations in which frontal sinus stenting is deemed necessary. Additional investigations with animal models, as well as clinical trials, may be warranted.

  4. Transhepatic implant of a trimmed Melody™ valved stent in tricuspid position in a 1-year-old infant.

    PubMed

    Cools, Bjorn; Rega, Filip; Gewillig, Marc

    2017-02-15

    Percutaneous valved stent implantation is precluded in small infants because large delivery sheaths and large devices. We describe a procedure in a 1-year-old boy in whom a 19 mm Epic™ valve in tricuspid position had become dysfunctional. As the internal diameter of the prosthetic valve was about 16 mm, the only available valve was the Melody™ valved stent. Technical modifications were required to address issues like venous access, the bulky delivery system, and the length of the valved stent. The Melody™ valved stent was surgically trimmed and mounted on a 16 mm Tyshak balloon, access was provided transhepatically through a short 18 Fr sheath. After deployment, the intrahepatic route was sealed with two vascular plugs (8 and 10 mm) in tandem. The procedure was uncomplicated with perfect valve function 18 months after implant. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Bloody tears and recurrent nasolacrimal duct obstruction due to a retained silicone stent.

    PubMed

    Kemp, Pavlina S; Allen, Richard C

    2014-06-01

    A 6-year-old girl with a history of bilateral nasolacrimal duct obstruction presented with recurrent tearing, discharge, and bloody tears from the right eye. The patient had a history of multiple prior probing and stenting procedures on the right nasolacrimal system. Endoscopic dacryocystorhinotomy revealed a retained portion of a prior stent and accompanying pyogenic granuloma, removal of which resolved her symptoms. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  6. Double bifurcation optimization stent system technique for left main stenosis.

    PubMed

    Vassilev, D; Mateev, H; Alexandrov, A; Karamfiloff, K; Gil, R J

    2014-12-01

    We present a first-in-man case with implantation in culottes' fashion of two dedicated coronary bifurcation stents (BiOSS Lim) in distal left main stenosis. The immediate procedural and very short-term result was excellent. © 2014, Wiley Periodicals, Inc.

  7. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulcsar, Zsolt, E-mail: kulcsarzsolt22@gmail.com; Yilmaz, Hasan; Bonvin, Christophe

    2010-12-15

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted ofmore » an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.« less

  8. One swallow does not a summer make but many swallows do: accumulating clinical evidence for nearly-eliminated peri-procedural and 30-day complications with mesh-covered stents transforms the carotid revascularisation field

    PubMed Central

    Hopkins, L. Nelson; Siddiqui, Adnan H.

    2017-01-01

    Atherosclerotic carotid artery stenosis (CS) continues to be a common cause of acute ischaemic stroke. Optimised medical therapy (OMT), the first-line treatment modality in CS, may reduce or delay – but it does not abolish – CS-related strokes. As per current AHA/ASA and ESC/ESVS/ESO guidelines, carotid artery stenting (CAS) is a less-invasive alternative to carotid endarterectomy (CEA) for CS revascularisation in primary and secondary stroke prevention. Ten-year follow-up from the CREST trial in patients with symptomatic and asymptomatic CS confirmed equipoise of CAS and CEA in the primary endpoint. Nevertheless CAS – using a widely open-cell, first-generation stent and first-generation (distal/filter) neuroprotection – has been criticised for its relative excess of (mostly minor) strokes by 30 days, a significant proportion of which were post-procedural. Atherosclerotic plaque protrusion through conventional carotid stent struts, confirmed on intravascular imaging, has been implicated as a leading mechanism of the relative excess of strokes with CAS vs. CEA, including delayed strokes with CAS. Different designs of mesh-covered carotid stents have been developed to prevent plaque prolapse. Several multi-centre/multi-specialty clinical studies with CGurad MicroNet-Covered Embolic Prevention Stent System (EPS) and RoadSaver/Casper were recently published and included routine DW-MRI cerebral imaging peri-procedurally and at 30 days (CGuard EPS). Data from more than 550 patients in mesh-covered carotid stent clinical studies to-date show an overall 30-day complication rate of ~1% with near-elimination of post-procedural events. While more (and long-term) evidence is still anticipated, these results – taken together with optimised intra-procedural neuroprotection in CAS (increased use of proximal systems including trans-carotid dynamic flow reversal) and the positive 12-month mesh-covered stent data reports in 2017 – are transforming the carotid revascularisation field today. Establishing effective algorithms to identify the asymptomatic subjects at stroke risk despite OMT, and large-scale studies with mesh-covered stents including long-term clinical and duplex ultrasound outcomes, are the next major goals. PMID:28798779

  9. Thrombin Injection Failure with Subsequent Successful Stent-Graft Placement for the Treatment of an Extracranial Internal Carotid Pseudoaneurysm in a 5-Year-Old Child

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Monaco, R. D.; Kohan, A. A., E-mail: andreskohan1@gmail.com; Martinez-Corvalan, M. P.

    Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.

  10. Transpopliteal stenting of femoral occlusions in patients with critical limb ischemia using a 4-French system.

    PubMed

    Spreen, Marlon; Vink, Ted; Knippenberg, Bob; Reekers, Jim; van Dijk, Lukas; Wever, Jan; van Eps, Randolph; van Overhagen, Hans

    2014-08-01

    In many patients with critical limb ischemia (CLI), transfemoral endovascular recanalization is the preferred treatment. Transpopliteal treatment may be used in patients with inaccessible groins. This retrospective study regards transpopliteal stenting of superficial femoral artery (SFA) occlusions using a 4F system. Eleven patients (4 male and 7 female [mean age 77 years]) underwent 12 attempts of transpopliteal recanalization of long SFA occlusions (Trans-Atlantic InterSociety Consensus B through D). All patients had CLI (Rutherford 4 to 6) and were nonoperable due to poor general condition. Indications for transpopliteal access were proximal/flush SFA occlusions (n = 5), failure of antegrade recanalization (n = 4), infected femoral-femoral crossover bypass (n = 2), and occlusion of both the native SFA and the femoral-popliteal bypass (n = 1). The popliteal artery was punctured under ultrasound guidance. Occlusions were recanalized subintimally, and 4F compatible stents were implanted. Technical success rate (<30 % residual stenosis) was achieved in 83 % of cases. In two patients, stent dislocation occurred while the sheath was removed. One arteriovenous fistula was successfully treated with additional stenting. During 6-month follow-up, there were no major amputations, and three patients died from nonrelated causes. Fifty percent of patients alive after 6 months improved to Rutherford score ≤3. The duplex restenosis (>50 %) rate at 6 months was 50 %. Transpopliteal primary stenting of complex SFA lesions in CLI for a temporary bypass is now technically feasible using a 4F system. Technical results are promising. Clinical results after 6 months are acceptable when taking into consideration that this approach may be the last option for limb salvage.

  11. [Proposed model of vascular trauma by mean of mechanical characterization of endovascular prostheses (stents) based on structural analysis by FEA].

    PubMed

    Bustamante, John; Uribe, Pablo; Sosa, Mauricio; Valencia, Raúl

    2016-01-01

    The accumulated evidence on angioplasty techniques with stents has raised a controversy about the factors that influence the final vascular response. Indeed, several studies have shown there might be re-stenosis between 30% to 40% about 6 months after placement, relating to the design of the device as one of the main causes. This paper proposes the functional characterization of endovascular stents, analyzing its mechanical influence in the vascular system and predicting implicit traumatic factors in the vessel. A structural analysis was made for several computational models of endovascular stents using Finite Element Analysis in order to predict the mechanical behavior and the vascular trauma. In this way, the stents were considered as tubular devices composed of multiple links under radial pressure loads, reflecting stress concentration effects. The analysis allowed to visualize how the geometry of stents is adjusted under several load conditions, in order to obtain the response of "solid-solid" interaction between the stent and the arterial wall. Thus, an analysis was performed in order to calculate stress, and a conceptual model that explains its mechanical impact on the stent-vessel interaction, was raised, to infer on the functionality from the design of the devices. The proposed conceptual model allows to determine the relationship between the conditions of mechanical interaction of the stents, and warns about the effects in what would be the operation of the device on the vascular environment. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  12. Endoscopic Gallbladder Drainage for Acute Cholecystitis

    PubMed Central

    Widmer, Jessica; Alvarez, Paloma; Sharaiha, Reem Z.; Gossain, Sonia; Kedia, Prashant; Sarkaria, Savreet; Sethi, Amrita; Turner, Brian G.; Millman, Jennifer; Lieberman, Michael; Nandakumar, Govind; Umrania, Hiren; Gaidhane, Monica

    2015-01-01

    Background/Aims Surgery is the mainstay of treatment for cholecystitis. However, gallbladder stenting (GBS) has shown promise in debilitated or high-risk patients. Endoscopic transpapillary GBS and endoscopic ultrasound-guided GBS (EUS-GBS) have been proposed as safe and effective modalities for gallbladder drainage. Methods Data from patients with cholecystitis were prospectively collected from August 2004 to May 2013 from two United States academic university hospitals and analyzed retrospectively. The following treatment algorithm was adopted. Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy and cystic duct stenting was initially attempted. If deemed feasible by the endoscopist, EUS-GBS was then pursued. Results During the study period, 139 patients underwent endoscopic gallbladder drainage. Among these, drainage was performed in 94 and 45 cases for benign and malignant indications, respectively. Successful endoscopic gallbladder drainage was defined as decompression of the gallbladder without incidence of cholecystitis, and was achieved with ERCP and cystic duct stenting in 117 of 128 cases (91%). Successful endoscopic gallbladder drainage was also achieved with EUS-guided gallbladder drainage using transmural stent placement in 11 of 11 cases (100%). Complications occurred in 11 cases (8%). Conclusions Endoscopic gallbladder drainage techniques are safe and efficacious methods for gallbladder decompression in non-surgical patients with comorbidities. PMID:26473125

  13. Endoscopic Management of Pancreatic Fluid Collections in Children.

    PubMed

    Nabi, Zaheer; Talukdar, Rupjyoti; Reddy, D Nageshwar

    2017-07-15

    The incidence of acute pancreatitis in children has increased over the last few decades. The development of pancreatic fluid collection is not uncommon after severe acute pancreatitis, although its natural course in children and adolescents is poorly understood. Asymptomatic fluid collections can be safely observed without any intervention. However, the presence of clinically significant symptoms warrants the drainage of these fluid collections. Endoscopic management of pancreatic fluid collection is safe and effective in adults. The use of endoscopic ultrasound (EUS)-guided procedure has improved the efficacy and safety of drainage of pancreatic fluid collections, which have not been well studied in pediatric populations, barring a scant volume of small case series. Excellent results of EUS-guided drainage in adult patients also need to be verified in children and adolescents. Endoprostheses used to drain pancreatic fluid collections include plastic and metal stents. Metal stents have wider lumens and become clogged less often than plastic stents. Fully covered metal stents specifically designed for pancreatic fluid collection are available, and initial studies have shown encouraging results in adult patients. The future of endoscopic management of pancreatic fluid collection in children appears promising. Prospective studies with larger sample sizes are required to establish their definitive role in the pediatric age group.

  14. Effects of the temporary placement of a self-expandable metallic stent in benign pyloric stenosis.

    PubMed

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-07-01

    The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration.

  15. Effects of the Temporary Placement of a Self-Expandable Metallic Stent in Benign Pyloric Stenosis

    PubMed Central

    Choi, Won Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-01-01

    Background/Aims The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Methods Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. Results No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Conclusions Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration. PMID:23898381

  16. Wave reflection and transmission in multiply stented blood vessels

    NASA Astrophysics Data System (ADS)

    Papathanasiou, T. K.; Movchan, A. B.; Bigoni, D.

    2017-06-01

    Closed circulatory systems display an exquisite balance between vascular elasticity and viscous fluid effects, to induce pulse-smoothing and avoid resonance during the cardiac cycle. Stents in the arterial tree alter this balance through stiffening and because a periodic structure is introduced, capable of interacting with the fluid in a complex way. While the former feature has been investigated, the latter received no attention so far. But periodic structures are the building blocks of metamaterials, known for their `non-natural' behaviour. Thus, the investigation of a stent's periodic microstructure dynamical interactions is crucial to assess possible pathological responses. A one-dimensional fluid-structure interaction model, simple enough to allow an analytical solution for situations of interest involving one or two interacting stents, is introduced. It is determined: (i) whether or not frequency bands exist in which reflected blood pulses are highly increased and (ii) if these bands are close to the characteristic frequencies of arteries and finally, (iii) if the internal structure of the stent can sensibly affect arterial blood dynamics. It is shown that, while the periodic structure of an isolated stent can induce anomalous reflection only in pathological conditions, the presence of two interacting stents is more critical, and high reflection can occur at frequencies not far from the physiological values.

  17. Wave reflection and transmission in multiply stented blood vessels

    PubMed Central

    Movchan, A. B.

    2017-01-01

    Closed circulatory systems display an exquisite balance between vascular elasticity and viscous fluid effects, to induce pulse-smoothing and avoid resonance during the cardiac cycle. Stents in the arterial tree alter this balance through stiffening and because a periodic structure is introduced, capable of interacting with the fluid in a complex way. While the former feature has been investigated, the latter received no attention so far. But periodic structures are the building blocks of metamaterials, known for their ‘non-natural’ behaviour. Thus, the investigation of a stent's periodic microstructure dynamical interactions is crucial to assess possible pathological responses. A one-dimensional fluid–structure interaction model, simple enough to allow an analytical solution for situations of interest involving one or two interacting stents, is introduced. It is determined: (i) whether or not frequency bands exist in which reflected blood pulses are highly increased and (ii) if these bands are close to the characteristic frequencies of arteries and finally, (iii) if the internal structure of the stent can sensibly affect arterial blood dynamics. It is shown that, while the periodic structure of an isolated stent can induce anomalous reflection only in pathological conditions, the presence of two interacting stents is more critical, and high reflection can occur at frequencies not far from the physiological values. PMID:28690408

  18. The STENTYS self-apposing stent technology in coronary artery disease: literature review and future directions.

    PubMed

    Lu, Huangling; de Winter, Robbert J; Koch, Karel T

    2018-06-21

    Coronary stent designs have been through extensive developments in the past few decades. Since the first introduction of the self-apposing STENTYS stent, several theoretical advantages of its nitinol platform have been clinically evaluated. This paper reviews the current status, ongoing work and future directions of this device. Areas covered: The OPEN (STENTYS Coronary Bifurcation Stent System fOr the PErcutaNeous treatment of de novo lesions in native bifurcated coronary arteries) trials revealed high technical success rates of the STENTYS performance in bifurcation lesions. The APPOSITION (Assessment of the Safety and Performance of the STENTYS self-expanding Coronary Stent in Acute Myocardial Infarction) trials demonstrated the safety and feasibility of the device in patients with acute myocardial infarction. Optical coherence tomography showed better short-term strut apposition in patients treated with the STENTYS stent in APPOSITION IV. The clinical outcomes of the device in saphenous vein graft lesions and left main coronary artery disease are favourable. Expert Commentary: Despite numerous theoretical advantages of the nitinol platform, superiority of the STENTYS self-apposing stent over currently available DES has not yet been proven. However, the ongoing registries evaluating the performance of the STENTYS Xposition will provide more insights in its clinical performance.

  19. Endovascular treatment of popliteal artery segments P1 and P2 in patients with critical limb ischemia: initial experience using a helical nitinol stent with increased radial force.

    PubMed

    Goltz, Jan P; Ritter, Christian O; Kellersmann, Richard; Klein, Detlef; Hahn, Dietbert; Kickuth, Ralph

    2012-06-01

    To evaluate efficacy, safety, and midterm patency of a helical, self-expanding nitinol stent after failed percutaneous transluminal angioplasty (PTA) of popliteal artery segments P1 and P2 in patients with chronic critical limb ischemia (CLI) or lifestyle-limiting claudication. Between February 2009 and March 2011, 40 patients (23 men; mean age 77±10 years) classified as Rutherford category 3 (n = 10) or 4/5 (n = 30) underwent PTA of the proximal and mid popliteal artery followed by implantation of a SUPERA stent for elastic recoil, residual stenosis, or flow-limiting dissection. All patients had an elevated operative risk. Before and after the procedure and during the 12-month follow-up, a clinical investigation, ankle-brachial-index (ABI) measurement, and color-coded duplex sonography and/or digital subtraction angiography were performed. Primary endpoints were limb salvage and anatomical patency at 12 months. Stent implantation was successful in all patients. The major complication rate was 7.5% (an access-site pseudoaneurysm, 2 retroperitoneal hematomas, and 1 death from retroperitoneal bleeding). Mean follow-up was 15.9 months (range 0.5-27.9). The mean baseline ABI of 0.37 significantly increased to 0.91 at 12 months (p<0.01). Three (7.5%) patients underwent bypass surgery owing to lack of clinical improvement (<0.10 improvement in ABI). Primary and secondary patency rates at 12 months in the 34 patients eligible for follow-up were 68.4% and 79.8%, respectively. The major amputation rate was 5% at 1 year. Five (12.5%) in-stent stenoses and 1 of 2 (5.0%) in-stent occlusions were successfully recanalized (the second occlusion was asymptomatic). Implantation of this helical stent into segments of the popliteal artery at the knee joint in CLI patients is a safe and clinically effective bailout method with acceptable intermediate patency.

  20. One-year clinical outcomes of ultra long apollo polymer-based Paclitaxel-eluting stents in patients with complex, long coronary artery lesions.

    PubMed

    Salarifar, Mojtaba; Kassaian, Seyed Ebrahim; Alidoosti, Mohammad; Haji-Zeinali, Ali Mohammad; Poorhoseini, Hamid Reza; Nematipour, Ebrahim; Amirzadegan, Alireza; Saroukhani, Sepideh

    2011-01-01

    For all the wealth of research comparing the efficacy of the different types of the drug-eluting stent (DES) such as sirolimus-, paclitaxel-, and zotarolimus-eluting stents, there is still a dearth of data on the different brands of each DES type. We aimed to investigate the one-year clinical outcomes, including major adverse cardiac events (MACE), of the use of the ultra long Apollo paclitaxel-eluting stent in patients with long atherosclerotic coronary artery lesions. According to a retrospective review of the Tehran Heart Center Registry of Interventional Cardiology, a single-center nonrandomized computerized data registry in which all adult patients who undergo single or multi-vessel percutaneous coronary intervention (PCI) are enrolled without any specific exclusion criteria, the mixed use of long Apollo paclitaxel-eluting stents and other types of the DES as well as myocardial infarction within forty-eight hours prior to the procedure was excluded. In total, 122 patients were enrolled in the study, and their baseline clinical, angiographic, and procedural characteristics were obtained. In addition, the patients' follow-up data and, most importantly, MACE during a one-year period after intervention were recorded. The mean follow-up duration was 14.1 ± 3.8 months. The one-year clinical follow-up data were obtained in 95.9 % of all the patients. The incidence of MACE was 5.7% during the entire study period. There was 1 death, which occurred during the initial days after PCI. The incidence of non-fatal myocardial infarction was 2.5% (3 cases), including one patient who underwent target vessel revascularization seven months later. Also, 3 patients with single-vessel disease and in-stent restenosis underwent coronary artery bypass grafting between five to ten months later. Our results showed that the Apollo paclitaxel-eluting stent might be regarded as a safe and effective treatment for long coronary lesions.

  1. Culprit lesion thrombus burden after manual thrombectomy or percutaneous coronary intervention-alone in ST-segment elevation myocardial infarction: the optical coherence tomography sub-study of the TOTAL (ThrOmbecTomy versus PCI ALone) trial.

    PubMed

    Bhindi, Ravinay; Kajander, Olli A; Jolly, Sanjit S; Kassam, Saleem; Lavi, Shahar; Niemelä, Kari; Fung, Anthony; Cheema, Asim N; Meeks, Brandi; Alexopoulos, Dimitrios; Kočka, Viktor; Cantor, Warren J; Kaivosoja, Timo P; Shestakovska, Olga; Gao, Peggy; Stankovic, Goran; Džavík, Vladimír; Sheth, Tej

    2015-08-01

    Manual thrombectomy has been proposed as a strategy to reduce thrombus burden during primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI). However, the effectiveness of manual thrombectomy in reducing thrombus burden is uncertain. In this substudy of the TOTAL (ThrOmbecTomy versus PCI ALone) trial, we compared the thrombus burden at the culprit lesion using optical coherence tomography (OCT) in patients treated with thrombectomy vs. PCI-alone. The TOTAL trial (N = 10 732) was an international, multicentre, randomized trial of thrombectomy (using the Export catheter, Medtronic Cardiovascular, Santa Rosa, CA, USA) in STEMI patients treated with primary PCI. The OCT substudy prospectively enrolled 214 patients from 13 sites in 5 countries. Optical coherence tomography was performed immediately after thrombectomy or PCI-alone and then repeated after stent deployment. Thrombus quantification was performed by an independent core laboratory blinded to treatment assignment. The primary outcome of pre-stent thrombus burden as a percentage of segment analysed was 2.36% (95% CI: 1.73-3.22) in the thrombectomy group and 2.88% (95% CI: 2.12-3.90) in the PCI-alone group (P = 0.373). Absolute pre-stent thrombus volume was not different (2.99 vs. 3.74 mm(3), P = 0.329). Other secondary outcomes of pre-stent quadrants of thrombus, post-stent atherothrombotic burden, and post-stent atherothrombotic volume were not different between groups. Manual thrombectomy did not reduce pre-stent thrombus burden at the culprit lesion compared with PCI-alone. Both strategies were associated with low thrombus burden at the lesion site after the initial intervention to restore flow. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  2. Colonic stenting as bridge to surgery versus emergency surgery for management of acute left-sided malignant colonic obstruction: a multicenter randomized trial (Stent-in 2 study)

    PubMed Central

    van Hooft, Jeanin E; Bemelman, Willem A; Breumelhof, Ronald; Siersema, Peter D; Kruyt, Philip M; van der Linde, Klaas; Veenendaal, Roeland A; Verhulst, Marie-Louise; Marinelli, Andreas W; Gerritsen, Josephus JGM; van Berkel, Anne-Marie; Timmer, Robin; Grubben, Marina JAL; Scholten, Pieter; Geraedts, Alfons AM; Oldenburg, Bas; Sprangers, Mirjam AG; Bossuyt, Patrick MM; Fockens, Paul

    2007-01-01

    Background Acute left-sided colonic obstruction is most often caused by malignancy and the surgical treatment is associated with a high mortality and morbidity rate. Moreover, these operated patients end up with a temporary or permanent stoma. Initial insertion of an enteral stent to decompress the obstructed colon, allowing for surgery to be performed electively, is gaining popularity. In uncontrolled studies stent placement before elective surgery has been suggested to decrease mortality, morbidity and number of colostomies. However stent perforation can lead to peritoneal tumor spill, changing a potentially curable disease in an incurable one. Therefore it is of paramount importance to compare the outcomes of colonic stenting followed by elective surgery with emergency surgery for the management of acute left-sided malignant colonic obstruction in a randomized multicenter fashion. Methods/design Patients with acute left-sided malignant colonic obstruction eligible for this study will be randomized to either emergency surgery (current standard treatment) or colonic stenting as bridge to elective surgery. Outcome measurements are effectiveness and costs of both strategies. Effectiveness will be evaluated in terms of quality of life, morbidity and mortality. Quality of life will be measured with standardized questionnaires (EORTC QLQ-C30, EORTC QLQ-CR38, EQ-5D and EQ-VAS). Morbidity is defined as every event leading to hospital admission or prolonging hospital stay. Mortality will be analyzed as total mortality as well as procedure-related mortality. The total costs of treatment will be evaluated by counting volumes and calculating unit prices. Including 120 patients on a 1:1 basis will have 80% power to detect an effect size of 0.5 on the EORTC QLQ-C30 global health scale, using a two group t-test with a 0.05 two-sided significance level. Differences in quality of life and morbidity will be analyzed using mixed-models repeated measures analysis of variance. Mortality will be compared using Kaplan-Meier curves and log-rank statistics. Discussion The Stent-in 2 study is a randomized controlled multicenter trial that will provide evidence whether or not colonic stenting as bridge to surgery is to be performed in patients with acute left-sided colonic obstruction. Trial registration Current Controlled Trials ISRCTN46462267. PMID:17608947

  3. Nasojejunal-stent technique (NJST): A new system to prevent fully covered metal stent migration in the treatment of benign esophageal diseases.

    PubMed

    Hernández Mondragón, Oscar Víctor; Cuellar, Raquel Palos; Murcio Pérez, Enrique

    2018-05-19

    Fully covered self-expandable metal stents (FCSEMS) have been used for the treatment of benign esophageal conditions such as perforation, leaks, and strictures [1]; high clinical success is reported [2]. Different anchoring methods have been described (clips, suturing devices, over-the-scope clips and Shim technique [2]), because of high migration rates (4-36%) [3,4]. However, not all cases are candidates, mostly in "difficult" cases where enteral feeding is needed [5]. We report the use of the nasojejunal-stent technique (NJST) to prevent migration of FCSEMS in three difficult cases. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. [Clinical application of a fully covered self-expandable metallic stent in treatment of airway fistula].

    PubMed

    Zhu, Qiang; Zang, Qi; Jiang, Zhong-min; Wang, Wei; Cao, Ming

    2013-06-01

    To assess the feasibility, safety and efficacy of the use of a fully covered self-expandable stent for the treatment of airway fistula. From August 2005 to November 2011, 9 patients underwent treatment by the introduction of a tracheo-bronchial or bronchial fully covered self-expandable metallic stent. There were 7 males and 2 females, aged from 28-65 years with a mean of 46 years. In this group, 7 cases were diagnosed as bronchopleural fistula, 1 case as tracheopleural fistula, 1 case as broncho-esophageal fistula, 8 cases with thoracic empyema. The fistula orifices were from 3.5-25.0 mm in diameter with a mean 8.4 mm. All patients received topical anesthesia, and L-shaped stent was placed in 6 patients and I-shaped stent in 3 patients under fluoroscopic guidance. After the stent placement, the patients with empyema were treated with continual irrigation of the empyema cavity. Stent placement in the tracheo-bronchial tree was technically successful in all patients, without procedure-related complications. The operating time was from 5-16 minutes, mean time (10 ± 4) minutes. Except for 1 patient, immediate closure of the airway fistula was achieved in the other patients after the procedure, as shown by the immediate cessation of bubbling in the chest drain system or the contrast examination. In this study, 1 patient coughed the inserted stent out due to irritable cough on the 5th day and had to receive repositioning of a new stent. Among the patients who were with empyema, 1 patient died of septicemia on the 8th day and 1 patient died of brain metastases from lung cancer 6 months after the stent insertion with empyema not cured, the other 6 patients' empyema healed from 2-5 months, mean time 3.7 months. Seven patients were followed from 3 to 36 months with a median of 13.5 months. During follow-up, 1 stent was removed from a patient 8 months after the stent implantation without empyema recurred. The remaining patient presented good tolerability to the existence of stent. The stents remained stable, no migration occurred, no empyema recurred, and the patient with broncho-esophageal fistula fed and drunk well. The use of fully covered self-expandable stents proved to be a safe, effective and fast minimally invasive method to treat airway fistula, especially for patients with a higher surgical risk or other failed treatments.

  5. Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions

    PubMed Central

    Tang, Zhe; Bai, Jing; Su, Shao-Ping; Lee, Pui-Wai; Peng, Liang; Zhang, Tao; Sun, Ting; Nong, Jing-Guo; Li, Tian-De; Wang, Yu

    2016-01-01

    Objective To evaluate the factors affecting optimal stent expansion in calcified lesions treated by aggressive plaque modification with rotational atherectomy (RA) and a cutting balloon (CB). Methods From January 2014 to May 2015, 92 patients with moderate to severe coronary calcified lesions underwent rotational atherectomy and intravascular ultrasound imaging at Chinese PLA General Hospital (Beijing, China) were included in this study. They were divided into a rotational artherectomy combined with cutting balloon (RACB) group (46 patients treated with RA followed by CB angioplasty) and an RA group (46 patients treated with RA followed by plain balloon angioplasty). Another 40 patients with similar severity of their calcified lesions treated with plain old balloon angioplasty (POBA) were demographically matched to the other groups and defined as the POBA group. All patients received a drug-eluting stent after plaque preparation. Lumen diameter and lumen diameter stenosis (LDS) were measured by quantitative coronary angiography at baseline, after RA, after dilatation, and after stenting. Optimal stent expansion was defined as the final LDS < 10%. Results The initial and post-RA LDS values were similar among the three groups. However, after dilatation, the LDS significantly decreased in the RACB group (from 54.5% ± 8.9% to 36.1% ± 7.1%) but only moderately decreased (from 55.7% ± 7.8% to 46.9% ± 9.4%) in the RA group (time × group, P < 0.001). After stenting, there was a higher rate of optimal stent expansion in the RACB group (71.7% in the RACB group, 54.5% in the RA group, and 15% in the POBA group, P < 0.001), and the final LDS was significantly diminished in the RACB group compared to the other two groups (6.0% ± 2.3%, 10.8% ± 3.3%, 12.7% ± 2.1%, P < 0.001). Moreover, an LDS ≤ 40% after plaque preparation (OR = 2.994, 95% CI: 1.297–6.911) was associated with optimal stent expansion, which also had a positive correlation with the appearance of a calcified ring split (r = 0.581, P < 0.001). Conclusions Aggressive plaque modification with RA and CB achieve more optimal stent expansion. An LDS ≤ 40% after plaque modification was a predictive factor for optimal stent expansion in calcified lesions. This parameter was also associated with the presence of calcified ring split. PMID:28321242

  6. External Ventricular Drain and Hemorrhage in Aneurysmal Subarachnoid Hemorrhage Patients on Dual Antiplatelet Therapy: A Retrospective Cohort Study.

    PubMed

    Hudson, Joseph S; Prout, Benjamin S; Nagahama, Yasunori; Nakagawa, Daichi; Guerrero, Waldo R; Zanaty, Mario; Chalouhi, Nohra; Jabbour, Pascal; Dandapat, Sudeepta; Allan, Lauren; Ortega-Gutierrez, Santiago; Samaniego, Edgar A; Hasan, David

    2018-04-11

    Stenting and flow diversion for aneurysmal sub arachnoid hemorrhage (aSAH) require the use of dual antiplatelet therapy (DAPT). To investigate whether DAPT is associated with hemorrhagic complication following placement of external ventricular drains (EVD) in patients with aSAH. Rates of radiographically identified hemorrhage associated with EVD placement were compared between patients who received DAPT for stenting or flow diversion, and patients who underwent microsurgical clipping or coiling and did not receive DAPT by way of a backward stepwise multivariate analysis. Four hundred forty-three patients were admitted for aSAH management. Two hundred ninety-eight patients required placement of an EVD. One hundred twenty patients (40%) were treated with stent-assisted coiling or flow diversion and required DAPT, while 178 patients (60%) were treated with coiling without stents or microsurgical clipping and did not receive DAPT. Forty-two (14%) cases of new hemorrhage along the EVD catheter were identified radiographically. Thirty-two of these hemorrhages occurred in patients on DAPT, while 10 occurred in patients without DAPT. After multivariate analysis, DAPT was significantly associated with radiographic hemorrhage [odds ratio: 4.92, 95% confidence interval: 2.45-9.91, P = .0001]. We did not observe an increased proportion of symptomatic hemorrhage in patients receiving DAPT (10 of 32 [31%]) vs those without (5 of 10 [50%]; P = .4508). Patients with aSAH who receive stent-assisted coiling or flow diversion are at higher risk for radiographic hemorrhage associated with EVD placement. The timing between EVD placement and DAPT initiation does not appear to be of clinical significance. Stenting and flow diversion remain viable options for aSAH patients.

  7. Comparison of cost-effectiveness of oral rapamycin plus bare-metal stents versus first generation of drug-eluting stents (from the Randomized Oral Rapamycin in Argentina [ORAR] 3 trial).

    PubMed

    Rodriguez, Alfredo E; Palacios, Igor; Rodriguez-Granillo, Alfredo M; Mieres, Juan R; Tarragona, Sonia; Fernandez-Pereira, Carlos; Solorzano, Leonardo; Pauletto, Ricardo; Serruys, Patrick W; Antoniucci, David

    2014-03-01

    The aim of this study was to compare 5-year cost-effectiveness and clinical outcomes of patients with oral rapamycin (OR) plus bare-metal stent versus the drug-eluting stent (DES) strategy. During 2006 to 2007, a total of 200 patients were randomized to OR (n = 100) and DES (n = 100). Primary end point was to compare costs of initial procedure and cost-effectiveness of both revascularization strategies. Safety was evaluated by the composite of death, myocardial infarction, and cerebrovascular accident. Efficacy was assessed by target vessel and target lesion revascularizations. The 2 groups had similar baseline demographic, clinical, and angiographic characteristics. In the DES group, paclitaxel-, zotarolimus-, and sirolimus-eluting stents were used. Five-year clinical follow-up was accomplished in 99% patients. The DES group had significantly higher procedural (p <0.001), discharge to first-year (p = 0.02), and 1- to 5-year costs (p <0.001) compared with the OR group. At 5 years, the composite end point of death, myocardial infarction, and cerebrovascular accident (12% in the OR group vs 25% in the DES group, p = 0.01) was significantly less in the OR group. Target vessel revascularization (14.5% in the OR group vs 21% in the DES group, p = 0.16) and target lesion revascularization (10% in the OR group vs 17.6% in the DES group, p = 0.05) were not significantly different. In conclusion, a strategy of OR plus bare-metal stent was cost saving than a first-generation DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Lesion complexity drives the cost of superficial femoral artery endovascular interventions

    PubMed Central

    Walker, Karen L.; Nolan, Brian W.; Columbo, Jesse A.; Rzucidlo, Eva M.; Goodney, Philip P.; Walsh, Daniel B.; Atkinson, Benjamin J.; Powell, Richard J.

    2017-01-01

    Objective Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. Methods A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. Results During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. Conclusions SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. PMID:26206581

  9. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com; Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com; Zheng, Fang, E-mail: fang-zheng-surgery@126.com

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portalmore » stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.« less

  10. Lesion complexity drives the cost of superficial femoral artery endovascular interventions.

    PubMed

    Walker, Karen L; Nolan, Brian W; Columbo, Jesse A; Rzucidlo, Eva M; Goodney, Philip P; Walsh, Daniel B; Atkinson, Benjamin J; Powell, Richard J

    2015-10-01

    Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  11. Percutaneous Treatment of Central Venous Stenosis in Hemodialysis Patients: Long-Term Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young Chul; Won, Jong Yun, E-mail: jywon@yumc.yonsei.ac.kr; Choi, Sun Young

    2009-03-15

    The purpose of this study was to evaluate the long-term outcomes of endovascular treatment of central venous stenosis in patients with arteriovenous fistulas (AVFs) for hemodialysis. Five hundred sixty-three patients with AVFs who were referred for a fistulogram were enrolled in this study. Among them, 44 patients showed stenosis (n = 35) or occlusions (n = 9) in the central vein. For the initial treatment, 26 patients underwent percutaneous transluminal angioplasty (PTA) and 15 patients underwent stent placements. Periods between AVF formation and first intervention ranged from 3 to 144 months. Each patient was followed for 14 to 60 months.more » Procedures were successful in 41 of 44 patients (93.2%). Primary patency rates for PTA at 12 and 36 months were 52.1% and 20.0%, and assisted primary patency rates were 77.8% and 33.3%, respectively. Primary patency rates for stent at 12 and 36 months were 46.7% and 6.7%, and assisted primary patency rates were 60.0% and 20.0%, respectively. Fifteen of 26 patients with PTAs underwent repeated interventions because of restenosis. Fourteen of 15 patients with a stent underwent repeated interventions because of restenosis and combined migration (n = 1) and shortening (n = 6) of the first stent. There was no significant difference in patency between PTAs and stent placement (p > 0.05). Average AVF patency duration was 61.8 months and average number of endovascular treatments was 2.12. In conclusion, endovascular treatments of central venous stenosis could lengthen the available period of AVFs. There was no significant difference in patency between PTAs and stent placement.« less

  12. Comparative Study of Esophageal Self-expandable Metallic Stent Insertion and Gastrostomy Feeding for Dysphagia Caused by Lung Cancer.

    PubMed

    Kim, Jihye; Min, Yang Won; Lee, Hyuk; Min, Byung Hoon; Lee, Joon Haeng; Rhee, Poong Lyul; Kim, Jae J

    2018-03-25

    Dysphagia is encountered in a large proportion of patients with lung cancer and is associated with malnutrition and a poor quality of life. This study compared the clinical outcomes of self-expandable metallic stent (SEMS) insertion and percutaneous gastrostomy (PG) feeding for patients with lung cancer and dysphagia. A total of 261 patients with lung cancer, who underwent either SEMS insertion (stent group) or PG (gastrostomy group) as an initial treatment procedure for dysphagia between July 1997 and July 2015 at the Samsung Medical Center, were reviewed retrospectively, and 84 patients with esophageal obstruction were identified. The clinical outcomes, including the overall survival, additional intervention, complications, and post-procedural nutritional status in the two groups, were compared. Among the 84 patients finally analyzed, 68 patients received SEMS insertion and 16 had PG. The stent group had less cervical obstruction and more mid-esophageal obstruction than the gastrostomy group. The Kaplan-Meier curves revealed similar overall survival in the two groups. Multivariate analysis showed that the two modalities had similar survival rates (PG compared with SEMS insertion, hazard ratio 0.682, p=0.219). Fifteen patients (22.1%) in the stent group received additional intervention, whereas there was no case in the gastrostomy group (p=0.063). The decrease in the serum albumin level after the procedure was lower in the gastrostomy group than in the stent group (-0.20±0.54 g/dL vs. -0.65±0.57 g/dL, p=0.013). SEMS insertion and PG feeding for relieving dysphagia by lung cancer had a comparable survival outcome. On the other hand, PG was associated with a better nutritional status.

  13. Treatment of bifurcation in-stent restenotic lesions with beta radiation using strontium 90 and sequential positioning pullback technique: procedural details and clinical outcomes.

    PubMed

    Costa, Ricardo; Joyal, Michel; Harel, Francois; Fox, Tim; Crocker, Ian; Arsenault, Andre; Gregoire, Jean; Bonan, Raoul

    2003-08-01

    In-stent restenotic lesions have been problematic for many patients with the need for multiple repeat percutaneous coronary interventions (PCI). The need for repeat PCI has been significantly reduced in patients since the advent of vascular brachytherapy. In-stent restenosis resulting in bifurcation presents even more of a challenge. The use of radiation therapy for the treatment of this kind of lesion has not yet been reported. The purpose of this paper is to present five cases of radiation therapy in bifurcation in-stent restenotic lesions using the intraluminal beta radiation catheter delivery system (Beta-Cath System, Novoste Corporation, Norcross, Georgia). We reviewed the database of patients enrolled in our Compassionate Use Registry between August 1999 and April 2002. The data is reported for 5 patients who received radiation in both branches of bifurcation lesions with the Beta-Cath catheter system. The mean diameter of the vessels was 3.1 mm 0.5 mm. The dose administered was from 18.3 to 23 Gy, with an overlap of 3.3 to 10.3 mm; the hinge angle between the branches went from 43.3 to 65.4 . Angiographic follow-up was obtained at 6 months in 4 patients, with a single patient showing a focal (< 5 mm) edge lesion treated by balloon angioplasty (TVR no TLR). No aneurysms or zones of ectasia were noted. Beta radiation with the Beta-Cath catheter system appears to be safe, secure and clinically useful in in-stent restenotic bifurcation lesions.

  14. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial.

    PubMed

    Kitano, Masayuki; Yamashita, Yukitaka; Tanaka, Kiyohito; Konishi, Hideyuki; Yazumi, Shujiro; Nakai, Yoshitaka; Nishiyama, Osamu; Uehara, Hiroyuki; Mitoro, Akira; Sanuki, Tsuyoshi; Takaoka, Makoto; Koshitani, Tatsuya; Arisaka, Yoshifumi; Shiba, Masatsugu; Hoki, Noriyuki; Sato, Hideki; Sasaki, Yuichi; Sato, Masako; Hasegawa, Kazunori; Kawabata, Hideaki; Okabe, Yoshihiro; Mukai, Hidekazu

    2013-11-01

    The requirements of biliary stents used in the palliation of malignant biliary obstruction are a long duration of patency and minimal adverse effects. Covered self-expandable metal stents (SEMSs) have been shown to prevent tumor ingrowth, which is the most frequent complication of uncovered SEMSs. However, because they are prone to migration, the superiority of covered SEMS has yet to be convincingly demonstrated. The aim of this study was to evaluate the superiority of covered over uncovered SEMSs in the palliation of distal biliary obstruction due to unresectable pancreatic carcinoma, using both stent types with relatively low axial force and uncovered flared ends to prevent their migration. From April 2009 to December 2010, 120 patients who were admitted to 22 tertiary-care centers because of distal biliary obstruction from unresectable pancreatic carcinomas were enrolled in this prospective randomized multicenter study. Patients were randomly assigned to receive a covered or uncovered SEMS deployed at the site of the biliary stricture during endoscopic retrograde cholangiopancreatography. Stent patency time, patient survival time, patient survival time without stent dysfunction (time to stent dysfunction or patient death), cause of stent dysfunction (ingrowth, overgrowth, migration, or sludge formation), and serious adverse events were compared between covered and uncovered SEMS groups. Patient survival time in the two groups did not significantly differ (median: 285 and 223 days, respectively; P=0.68). Patient survival time without stent dysfunction was significantly longer in the covered than in the uncovered SEMS group (median: 187 vs. 132 days; P=0.043). Stent patency was also significantly longer in the covered than in the uncovered SEMS group (mean±s.d.: 219.3±159.1 vs. 166.9±124.9 days; P=0.047). Reintervention for stent dysfunction was performed in 14 of 60 patients with covered SEMSs (23%) and in 22 of 60 patients with uncovered SEMSs (37%; P=0.08). Stent dysfunction was caused by tumor ingrowth, tumor overgrowth, and sludge formation in 0 (0%), 3 (5%), and 11 (18%) patients in the covered SEMSs group, and in 15 (25%), 2 (3%), and 6 (10%) patients in the uncovered SEMSs group, respectively. Stent migration was not observed in either group. Rates of tumor overgrowth and sludge formation did not significantly differ between the two groups, whereas the rate of tumor ingrowth was significantly lower in the covered than in the uncovered SEMS group (P<0.01). Acute pancreatitis occurred in only one patient in the covered SEMS group. Acute cholecystitis occurred in one patient in the covered SEMS group and in two patients in the uncovered SEMS group. There was no significant difference between the two groups in the incidence of serious adverse events. By preventing tumor ingrowth and migration, covered SEMSs with an anti-migration system had a longer duration of patency than uncovered SEMSs, which recommends their use in the palliative treatment of patients with biliary obstruction due to pancreatic carcinomas.

  15. Our ultrasonographic experience in the management of symptomatic hydronephrosis during pregnancy.

    PubMed

    Dell'Atti, Lucio

    2016-03-01

    The aim of the present study was to document the role of ultrasound in the diagnosis and management of symptomatic hydronephrosis during pregnancy. In this study, we reviewed 36 consecutive cases of pregnant women whose pregnancy was complicated by symptomatic hydronephrosis. In all patients, management was initially conservative (analgesics and fluids) after hospitalization. The following criteria were used to indicate double-J stent placement under US guidance rather than a conservative treatment: persistent pain with no improvement after conservative treatment, progressive hydronephrosis (>2 cm dilatation of the renal pelvis) or presence of uterine contractions. The mean patient's age was 25 years (17-35) and gestational age at clinical presentation was 24 weeks (13-37). 81 % of cases had a renal pelvis dilatation >2 cm, while in only 19 % of cases there was a hydronephrosis between 1 and 2 cm in diameter; however, calculi were confirmed only in 25 patients. 28 patients required an invasive management with double-J stent insertion under US guidance. The sensitivity and specificity of US in the etiological diagnosis of hydronephrosis during pregnancy was 83 and 91 %, respectively. Conservative management with medical therapy and observation should be the first-line treatment approach. In our opinion a rapid ureteral decompression with the insertion of a ureteral double-J stent, under US visualization, is the safest method in the treatment of pregnant women with obstructed renal systems.

  16. Long-term angiographic outcome of stent-assisted coiling compared to non-assisted coiling of intracranial saccular aneurysms

    PubMed Central

    Ozretić, David; Radoš, Marko; Pavliša, Goran; Poljaković, Zdravka

    2015-01-01

    Aim To compare angiographic result at long-term follow-up, and rates of progressive occlusion, recurrence, and retreatment of stent-assisted coiled (SAC) and non-assisted coiled (NAC) intracranial saccular aneurysms. Methods Retrospective evaluation of department records identified 260 patients with 283 saccular intracranial aneurysms who had long-term angiographic follow-up (more than 12 months) and were successfully treated with SAC (89 aneurysms) or NAC (194 aneurysms) at the University Hospital Center Zagreb from June 2005 to July 2012. Initial and control angiographic results in both groups were graded using Roy/Raymond scale, converted to descriptive terms, and the differences between them were evaluated for statistical significance. A multivariate analysis was performed to identify factors related to progression of aneurysm occlusion and recurrence at follow-up, and those related to aneurysm retreatment. Results There were more progressively occluded aneurysms in SAC group (38 of 89 aneurysms, 42.7%) than in NAC group (46 of 194, 23.7%) (P = 0.002), but there were no significant differences in the rates of recanalization, regrowth, and stable result. Multivariate logistic regression identified the use of stent as the most important factor associated with progressive occlusion (P = 0.015, odds ratio 2.22, 95% confidence interval 1.17-4.21), and large aneurysm size and posterior circulation location as most predictive of aneurysm recurrence and retreatment. Conclusion The use of stent is associated with delayed occlusion of initially incompletely coiled aneurysms during follow-up, but does not reduce the rate of recurrence and retreatment compared to coiling alone. Long-term angiographic follow-up is needed for both SAC and NAC aneurysms. PMID:25727039

  17. Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    PubMed

    Floren, Michael G; Günther, Rolf W; Schmitz-Rode, Thomas

    2004-05-01

    To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The field strength was set to a maximum of 90 kA/m within a frequency range from 80 kHz to 320 kHz. The electromagnetic field was emitted by a custom-made water-cooled copper winding antenna. A flow model for stent heating was set up to assess the increase in temperature of an expanded 316L stainless steel stent with typical coronary stent dimensions of 3.5 mm diameter and 14.5 mm in length, and in a second setup with 4.5 mm diameter and 13 mm in length, respectively. The stent was located in a bioartificial artery, simulated by a fibrinogen matrix with a defined number of vital cells. The system was exposed to a pulsating perfusion and to an electromagnetic field of 200 kHz over a period of 20 minutes and in a second setup to an electromagnetic field of 300 kHz and increasing intensity up to maximum power-output. Afterward, the artificial vessel was sliced and examined by fluorescence microscopy to evaluate the number and location of damaged cells. The calorimetric tests show an exponential correlation of energy uptake in the stent with an increase in frequency and a constant generator output. At a frequency of 80 kHz, the power uptake accounts for 0.1 W (250 kHz 1.0 W; 320 kHz 1.9 W, respectively). The flow tests confirmed feasibility to elevate the stent temperature from 37 degrees C body temperature to 44 degrees C at 200 kHz within 55 seconds. The temperature increase of the fluid passing the heated vessel region was only marginal (maximum of 0.5 degrees C). Cell necrosis after 20 minutes of treatment was not observed. In a second set-up with 4.5 mm stent diameter, a frequency of 300 kHz and with maximum power output, the stent temperature was increased to 80 degrees C and there was extensive necrosis area around the stent. Treatment time and stent temperature were optimized in further tests. Selective noninvasive energy transfer to coronary stainless steel stents by inductive heating is possible within a wide range of power. By thermal conduction, vital cells close to the stent struts can be affected. The frequency of 200 kHz turned out to be favorable. There is still room for further optimization of energy dosage with regard to material and stent design, to induce controlled cell death. The method has potential to serve as an alternative approach for prevention of instent restenosis.

  18. Modulating the Release Kinetics of Paclitaxel from Membrane-Covered Stents Using Different Loading Strategies

    PubMed Central

    Sydow-Plum, Georg; Haidar, Ziyad S.; Merhi, Yahye; Tabrizian, Maryam

    2008-01-01

    Membrane-covered Express2TM Monorail® stents composed of chitosan (CH) blended with polyethylene oxide (PEO) in 70:30% wt (CH-PEO) were coated with a monolayer of hyaluronic acid (HA). This significantly improved the resistance to platelet adhesion and demonstrated excellent mechanical properties, resisting the harsh conditions during stent crimping and subsequent inflation. CH-PEO/HA membrane was then combined with a paclitaxel (Pac) delivery system via three different approaches for comparison of release profiles of Pac. The activity of Pac in these systems was confirmed since its presence in the membrane significantly decreased cell viability of U937 macrophages. Presented results are promising for applications requiring different release patterns of hydrophobic drugs.

  19. Reduction of In-Stent Restenosis Risk on Nickel-Free Stainless Steel by Regulating Cell Apoptosis and Cell Cycle

    PubMed Central

    Li, Liming; Pan, Shuang; Zhou, Xiaohang; Meng, Xin; Han, Xiaoxi; Ren, Yibin; Yang, Ke; Guan, Yifu

    2013-01-01

    High nitrogen nickel-free austenitic stainless steel (HNNF SS) is one of the biomaterials developed recently for circumventing the in-stent restenosis (ISR) in coronary stent applications. To understand the ISR-resistance mechanism, we have conducted a comparative study of cellular and molecular responses of human umbilical vein endothelial cells (HUVECs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel) which is the stent material used currently. CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profile of HUVECs exposed to HNNF SS and 316L SS, respectively. Flow cytometry analysis revealed that 316L SS could activate the cellular apoptosis more efficiently and initiate an earlier entry into the S-phase of cell cycle than HNNF SS. At the molecular level, qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were overexpressed on 316L SS. Further examination indicated that nickel released from 316L SS triggered the cell apoptosis via Fas-Caspase8-Caspase3 exogenous pathway. These molecular mechanisms of HUVECs present a good model for elucidating the observed cellular responses. The findings in this study furnish valuable information for understanding the mechanism of ISR-resistance on the cellular and molecular basis as well as for developing new biomedical materials for stent applications. PMID:23638002

  20. Single-stage intraoperative transhepatic biliary stenting in patients with unresectable hepatobiliary pancreatic tumors.

    PubMed

    Iwasaki, Yoshimi; Kubota, Keiichi; Kita, Junji; Katoh, Masato; Shimoda, Mitsugi; Sawada, Tokihiko; Iso, Yukihiro

    2013-02-01

    The current study was conducted to evaluate the safety and utility of intraoperative transhepatic biliary stenting (ITBS) in patients with unresectable malignant biliary obstruction (UMBO) diagnosed intraoperatively. In this study, 50 patients who underwent ITBS for UMBO between April 2001 and May 2009 were retrospectively reviewed. For 26 patients who underwent preoperative percutaneous transhepatic biliary drainage (PTBD), the expandable metallic stent (EMS) was inserted intraoperatively by the PTBD route in a single stage. For 24 patients, the intrahepatic bile ducts were intentionally dilated by injection of saline via the endoscopic nasobiliary drainage or the percutaneous transhepatic gallbladder drainage route, and the puncture was performed under intraoperative ultrasound guidance followed by guidewire and catheter insertion. Thereafter, the EMS was placed in the same manner. The initial postoperative complications and long-term results of ITBS were evaluated. In all cases, ITBS was technically successful. Stenting alone was performed in 22 patients and stenting combined with other procedures in 28 patients. Hospital mortality occurred for three patients (6 %), and complication-related mortality occurred in two cases (4 %). There were nine cases (18 %) of postoperative complications. The median survival time was 179 days, and the EMS patency time was 137 days. During the follow-up period, EMS occlusion occurred in 23 cases (46 %). Best supportive care was a significant independent risk factor for early mortality within 100 days after ITBS (p = 0.020, odds ratio, 9.398). Single-stage ITBS is feasible for palliation of UMBO and seems to have a low complication rate.

  1. Quantification of abdominal aortic deformation after EVAR

    NASA Astrophysics Data System (ADS)

    Demirci, Stefanie; Manstad-Hulaas, Frode; Navab, Nassir

    2009-02-01

    Quantification of abdominal aortic deformation is an important requirement for the evaluation of endovascular stenting procedures and the further refinement of stent graft design. During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and, the stent graft. This deformation can affect the flow characteristics and morphology of the aorta which have been shown to be elicitors for stent graft failures and be reason for reappearance of aneurysms. We present a method for quantifying the deformation of an aneurysmatic aorta imposed by an inserted stent graft device. The outline of the procedure includes initial rigid alignment of the two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. This is accomplished by preprocessing and remodeling of the pre- and postoperative aortic shapes before performing a non-rigid registration. We further narrow the resulting displacement fields to only include local non-rigid deformation and therefore, eliminate all remaining global rigid transformations. Finally, deformations for specified locations can be calculated from the resulting displacement fields. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results and evaluation of the usage of deformation quantification were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.

  2. Rotational atherectomy before paclitaxel-eluting stent implantation in complex calcified coronary lesions: Two-year clinical outcome of the randomized ROTAXUS trial.

    PubMed

    de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-03-01

    In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.

  3. [Evaluation of Radiation Dose during Stent-graft Treatment Using a Hybrid Operating Room System].

    PubMed

    Haga, Yoshihiro; Chida, Kouichi; Kaga, Yuji; Saitou, Kazuhisa; Arai, Takeshi; Suzuki, Shinichi; Iwaya, Yoshimi; Kumasaka, Eriko; Kataoka, Nozomi; Satou, Naoto; Abe, Mitsuya

    2015-12-01

    In recent years, aortic aneurysm treatment with stent graft grafting in the X-ray fluoroscopy is increasing. This is an endovascular therapy, because it is a treatment which includes the risk of radiation damage, having to deal with radiation damage, to know in advance is important. In this study, in order to grasp the trend of exposure stent graft implantation in a hybrid operating room (OR) system, focusing on clinical data (entrance skin dose and fluoroscopy time), was to count the total. In TEVAR and EVAR, fluoroscopy time became 13.40 ± 7.27 minutes, 23.67 ± 11.76 minutes, ESD became 0.87 ± 0.41 mGy, 1.11 ± 0.57 mGy. (fluoroscopy time of EVAR was 2.0 times than TEVAR. DAP of EVAR was 1.2 times than TEVAR.) When using the device, adapted lesions and usage are different. This means that care changes in exposure-related factors. In this study, exposure trends of the stent graft implantation was able to grasp. It can be a helpful way to reduce/optimize the radiation dose in a hybrid OR system.

  4. Drug-eluting versus bare-metal coronary stents: where are we now?

    PubMed

    Amoroso, Nicholas S; Bangalore, Sripal

    2012-11-01

    Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).

  5. Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms.

    PubMed

    Kono, K; Terada, T

    2013-10-01

    SACE is performed for complex aneurysms. There are several configurations of stent placement for bifurcation aneurysms. We investigated hemodynamics among 8 different configurations of stent placement, which may relate to the recanalization rate. We created a silicone block model of a patient-specific asymmetric bifurcation aneurysm. Enterprise closed-cell stents were deployed in the model as various configurations. 3D images of these stents were obtained by micro-CT. We performed CFD simulations for a no-stent model and 8 stent models: a single stent from a proximal vessel to a right or left distal vessel, a horizontal stent, a kissing-Y stent with a uniformly narrowed structure, a nonoverlapping-Y stent, a virtual-Y stent with no narrowed structure (fusion of 2 single stents), and 2 different crossing-Y stents with a focally narrowed structure. Hemodynamic parameters were evaluated. Cycle-averaged velocity and WSS in the aneurysm were reduced because of stent placement in the following order: single stent (19% reduction in cycle-averaged velocity) < nonoverlapping-Y stent (29%) < virtual-Y stent (32%) < horizontal stent (39%) < kissing-Y stent (48%) < crossing-Y stent (54%). Kissing- and crossing-Y stents redirected impingement flow into the distal vessels because of lowered porosity of stents due to narrowed structures. Among 8 different configurations of stent placement, kissing- and crossing-Y stents showed the strongest reduction in flow velocity in the aneurysm because of lowered porosity of stents and redirection of impingement flow. This may be a desirable reconstruction of flow hemodynamics and may decrease recanalization rates in SACE.

  6. Effects of antibacterial nanostructured composite films on vascular stents: hemodynamic behaviors, microstructural characteristics, and biomechanical properties.

    PubMed

    Cheng, Han-Yi; Hsiao, Wen-Tien; Lin, Li-Hsiang; Hsu, Ya-Ju; Sinrang, Andi Wardihan; Ou, Keng-Liang

    2015-01-01

    The purpose of this research was to investigate stresses resulting from different thicknesses and compositions of hydrogenated Cu-incorporated diamond-like carbon (a-C:H/Cu) films at the interface between vascular stent and the artery using three-dimensional reversed finite element models (FEMs). Blood flow velocity variation in vessels with plaques was examined by angiography, and the a-C:H/Cu films were characterized by transmission electron microscopy to analyze surface morphology. FEMs were constructed using a computer-aided reverse design system, and the effects of antibacterial nanostructured composite films in the stress field were investigated. The maximum stress in the vascular stent occurred at the intersections of net-like structures. Data analysis indicated that the stress decreased by 15% in vascular stents with antibacterial nanostructured composite films compared to the control group, and the stress decreased with increasing film thickness. The present results confirmed that antibacterial nanostructured composite films improve the biomechanical properties of vascular stents and release abnormal stress to prevent restenosis. The results of the present study offer the clinical benefit of inducing superior biomechanical behavior in vascular stents. © 2014 Wiley Periodicals, Inc.

  7. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    PubMed

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  8. An Alternative Approach for Treating a Type Ia Endoleak after Conventional EVAR Using the Nellix Endovascular Aneurysm Sealing.

    PubMed

    Martinelli, Ombretta; Fresilli, Mauro; Irace, Luigi; Venosi, Salvatore; Jabbour, Jihad; Picone, Veronica; Maruca, Debora; Di Girolamo, Alessia; Gossetti, Bruno

    2018-05-01

    To report the use of a Nellix endovascular aneurysm sealing (EVAS) device, to successfully treat a type Ia endoleak (EL) after an endovascular aortic repair (EVAR). A 70-year-old man was diagnosed with a 90-mm aortic aneurysm, suspicious for being inflammatory. It was initially treated successfully, with a Medtronic Endurant (Medtronic, Minneapolis, MN, USA). Five years after the index endovascular repair, an asymptomatic type Ia EL was detected on duplex ultrasound and computed tomographic angiogram. Other endovascular solutions in the form of proximal cuff, chimney was considered difficult to execute due to challenges in planning, manipulation, and renal cannulation caused by the short proximal sealing zone above the existing stent graft and the constraints of the previous endograft. Thus, a relining of the previous endoprothesis was performed using the Nellix system (Endologix, Inc., Irvine, CA, USA). One-year follow-up imaging demonstrated successful resolution of the EL and persistent sealing of the Nellix device. Nellix EVAS system can be an alternative and safe option for relining a stent graft with a type Ia EL. Nellix platform can be added to the clinician's armamentarium for treating type Ia EL after conventional EVAR of infrarenal abdominal aortic aneurysm (AAA). Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Use of biliary stent in laparoscopic common bile duct exploration.

    PubMed

    Lyon, Matthew; Menon, Seema; Jain, Abhiney; Kumar, Harish

    2015-05-01

    It is well supported in the literature that laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis has equal efficacy when compared to ERCP followed by laparoscopic cholecystectomy. Decompression after supra-duodenal choledochotomy is common practice as it reduced the risk of bile leaks. We conducted a prospective non-randomized study to compare outcomes and length of stay in patients undergoing biliary stent insertion versus T-tube drainage following LCBDE via choledochotomy. The study involved 116 patients with choledocholithiasis who underwent LCBDE and decompression of the biliary system by either ante-grade biliary stent or T-tube insertion. A 7 French straight/duodenal curve biliary Diagmed™ stent (9-11 cm) was placed in 82 patients (Biliary Stent Group). T-tube insertion was used for 34 patients (T-tube group). The length of hospital stay and complications for the selected patients were recorded. All trans-cystic common bile duct explorations were excluded from the study. The mean hospital stay for patients who underwent ante-grade biliary stent or T-tube insertion after LBCDE were 1 and 3.4 days, respectively. This is a statistically significant result with a p value of less than 0.001. Of the T-tube group, two patients required laparoscopic washout due to bile leaks, one had ongoing biliary stasis and one reported ongoing pain whilst the T-tube was in situ. A complication rate of 11.2%, this was a significant finding. There were no complications or concerns reported for the Biliary Stent Group. Our results show that there is a significant reduction in length of hospital stay and morbidity for patients that have ante-grade biliary stent decompression of the CBD post laparoscopic choledochotomy when compared T-tube drainage. This implies that ante-grade biliary stent insertion is likely to reduce costs and increase overall patient satisfaction. We support the use of ante-grade biliary stent insertion during LCBDE when primary closure is not preferred.

  10. Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases.

    PubMed

    Son, Donghee; Lee, Jongha; Lee, Dong Jun; Ghaffari, Roozbeh; Yun, Sumin; Kim, Seok Joo; Lee, Ji Eun; Cho, Hye Rim; Yoon, Soonho; Yang, Shixuan; Lee, Seunghyun; Qiao, Shutao; Ling, Daishun; Shin, Sanghun; Song, Jun-Kyul; Kim, Jaemin; Kim, Taeho; Lee, Hakyong; Kim, Jonghoon; Soh, Min; Lee, Nohyun; Hwang, Cheol Seong; Nam, Sangwook; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong

    2015-06-23

    Implantable endovascular devices such as bare metal, drug eluting, and bioresorbable stents have transformed interventional care by providing continuous structural and mechanical support to many peripheral, neural, and coronary arteries affected by blockage. Although effective in achieving immediate restoration of blood flow, the long-term re-endothelialization and inflammation induced by mechanical stents are difficult to diagnose or treat. Here we present nanomaterial designs and integration strategies for the bioresorbable electronic stent with drug-infused functionalized nanoparticles to enable flow sensing, temperature monitoring, data storage, wireless power/data transmission, inflammation suppression, localized drug delivery, and hyperthermia therapy. In vivo and ex vivo animal experiments as well as in vitro cell studies demonstrate the previously unrecognized potential for bioresorbable electronic implants coupled with bioinert therapeutic nanoparticles in the endovascular system.

  11. Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

    PubMed Central

    Kumar, Sunil; Fusaro, Mario; Amoroso, Nicholas; Kirtane, Ajay J; Byrne, Robert A; Williams, David O; Slater, James; Cutlip, Donald E; Feit, Frederick

    2012-01-01

    Objectives To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. Design Mixed treatment comparison meta-analysis. Data sources and study selection PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. Primary outcomes Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). Results From 42 trials with 22 844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents∼sirolimus eluting stents>paclitaxel eluting stents∼zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of “any” stent thrombosis. Conclusions Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such that the everolimus eluting stent was the most efficacious and safe. PMID:22885395

  12. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    PubMed

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ciampi, Juan J., E-mail: juanciampi@hotmail.com; Lanciego, Carlos; Navarro, Sofia

    The objective of the present study was to evaluate, in a prospective, single-center study, the effectiveness of the Wilhelm-type stent used in interventional radiology for the management of epiphora. Patients (n = 104; mean age 64 [range 25-88]; 33 male and 71 female) with severe epiphora had the stents inserted (135 stents in 115 eyes) to treat obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 83 cases, chronic dacryocystitis in 31, cases and postsurgical status in 1 case. The overall technical success rate of stent placement was near 94%. Resolution of epiphora was complete inmore » 105 cases and partial in 3 cases. During a mean 13-month follow-up (range 1 week to 28 months), the median duration of primary patency was 11 months, and the percentage of patency at 6 months was 60.8%, at 1 year was 39.6%, and at 2 years was 25%. Stents malfunctioned in 54 cases, and all were easily withdrawn except in 1 case. Of these 27 cases, patency recovered spontaneously in 9 and by way of a second stent in 18. Secondary patency was 50%. Factors presdisposing to lower primary patency are inflammatory etiology and location of the obstruction. The benefit of stent deployment is clear with respect to the resolution of epiphora in candidate patients for percutaneous treatment. Technical and/or design improvements would be welcomed.« less

  14. The use of double lasso, fully covered self-expandable metal stents with new "anchoring flap" system in the treatment of benign biliary diseases.

    PubMed

    Mangiavillano, B; Manes, G; Baron, T H; Frego, R; Dinelli, M; Radaelli, F; Teruzzi, V; Amato, A; Pallotta, S; Santoro, T; Masci, E

    2014-09-01

    Many benign biliary diseases (BBD) can be treated with fully covered, self-expandable metal stents (FCSEMS) but stent migration occurs in up to 35.7 %. The aim of this study was to prospectively assess the rate of, safety and effectiveness and stent migration of a new biliary FCSEMS with an anti-migration flap (FCSEMS-AF) in patients with BBD. This was a prospective study from four Italian referral endoscopy centers of 32 consecutive patients (10 females and 22 males; mean age: 60.1 ± 14.8 years; range: 32-84 years) with BBD who were offered endoscopic placement of a FCSEMS-AF as first-line therapy. Were 24 strictures and 8 leaks. Stent placement was technically successful in 32/32 patients (100 %). Immediate clinical improvement was seen in all 32 patients (100 %). One late stent migration occurred (3.3 %). FCSEMS-AF were removed from 30 of the 32 patients (93.7 %) at a mean (± SD) of 124.4 ± 84.2 days (range: 10-386 days) after placement. All patients remained clinically and biochemically well at 1- and 3-month follow-up. One patient (3.3 %) with a post-laparoscopic cholecystectomy stricture developed distal stent migration at 125 days. This new FCSEMS with anti-migration flap seems to be a safe and effective first-line treatment option for patients with BBD.

  15. A novel biliary stent coated with silver nanoparticles prolongs the unobstructed period and survival via anti-bacterial activity

    PubMed Central

    Yang, Fuchun; Ren, Zhigang; Chai, Qinming; Cui, Guangying; Jiang, Li; Chen, Hanjian; Feng, Zhiying; Chen, Xinhua; Ji, Jian; Zhou, Lin; Wang, Weilin; Zheng, Shusen

    2016-01-01

    Symptomatic biliary stricture causes life-threatening complications, such as jaundice, recurrent cholangitis and secondary biliary cirrhosis. Fully covered self-expanding metal stents (FCSEMSs) are gaining acceptance for treatments of benign biliary stricture and palliative management of malignant biliary obstructions. However, the high rate of FCSEMS obstruction limits their clinic use. In this study, we developed a novel biliary stent coated with silver nanoparticles (AgNPs) and investigated its efficacy both in vitro and in vivo. We first identified properties of the AgNP complex using ultraviolet detection. The AgNP complex was stable without AgNP agglomeration, and Ag abundance was correspondingly increased with an increased bilayer number. The AgNP biliary stent demonstrated good performance in the spin-assembly method based on topographic observation. The AgNP biliary stent also exhibited a long-term anti-coagulation effect and a slow process of Ag+ release. In vitro anti-bacteria experiments indicated that the AgNP biliary stent exhibited high-efficiency anti-bacterial activity for both short- and long-term periods. Importantly, application of the AgNP biliary stent significantly prolonged the unobstructed period of the biliary system and improved survival in preclinical studies as a result of its anti-microbial activity and decreased granular tissue formation on the surface of the anastomotic biliary, providing a novel and effective treatment strategy for symptomatic biliary strictures. PMID:26883081

  16. Prospective Multicenter Study on the Challenges Inherent to Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.

    PubMed

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng

    2018-06-22

    Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

  17. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    PubMed

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  18. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

    PubMed Central

    Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick

    2013-01-01

    Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased mortality compared with cobalt chromium everolimus eluting stents (1.52, 1.02 to 2.22). Overall, among all stent types, the newer generation durable polymer drug eluting stents (zotarolimus eluting stent-Resolute, cobalt chromium everolimus eluting stents, and platinum chromium everolimus eluting stents) were the most efficacious (lowest target vessel revascularization rate) stents, and cobalt chromium everolimus eluting stents were the safest with significant reductions in definite stent thrombosis (rate ratio 0.35, 0.21 to 0.53), myocardial infarction (0.65, 0.55 to 0.75), and death (0.72, 0.58 to 0.90) compared with bare metal stents. Conclusions Biodegradable polymer drug eluting stents are superior to first generation durable polymer drug eluting stents but not to newer generation durable polymer stents in reducing target vessel revascularization. Newer generation durable polymer stents, and especially cobalt chromium everolimus eluting stents, have the best combination of efficacy and safety. The utility of biodegradable polymer stents in the context of excellent clinical outcomes with newer generation durable polymer stents needs to be proven. PMID:24212107

  19. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    PubMed

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  20. Classification and outcomes of extended arch repair for acute Type A aortic dissection: a systematic review and meta-analysis.

    PubMed

    Smith, Holly N; Boodhwani, Munir; Ouzounian, Maral; Saczkowski, Richard; Gregory, Alexander J; Herget, Eric J; Appoo, Jehangir J

    2017-03-01

    Distal extent of repair in patients undergoing surgery for acute Type A aortic dissection (ATAAD) is controversial. Emerging hybrid techniques involving open and endovascular surgery have been reported in small numbers by select individual centres. A systematic review and meta-analysis was performed to investigate the outcomes following extended arch repair for ATAAD. A classification system is proposed of the different techniques to facilitate discussion and further investigation. Using Ovid MEDLINE, 38 studies were identified reporting outcomes for 2140 patients. Studies were categorized into four groups on the basis of extent of surgical aortic resection and the method of descending thoracic aortic stent graft deployment; during circulatory arrest (frozen stented elephant trunk) or with normothermic perfusion and use of fluoroscopy (warm stent graft): (I) surgical total arch replacement, (II) total arch and frozen stented elephant trunk, (III) hemiarch and frozen stented elephant trunk and (IV) total arch and warm stent graft. Perioperative event rates were obtained for each of the four groups and the entire cohort using pooled summary estimates. Linearized rates of late mortality and reoperation were calculated. Overall pooled hospital mortality for extended arch techniques was 8.6% (95% CI 7.2-10.0). Pooled data categorized by surgical technique resulted in hospital mortality of 11.9% for total arch, 8.6% total arch and frozen stented elephant trunk, 6.3% hemiarch and frozen stented elephant trunk and 5.5% total arch and 'warm stent graft'. Overall incidence of stroke for the entire cohort was 5.7% (95% CI 3.6-8.2). Rate of spinal cord ischaemia was 2.0% (95% CI 1.2-3.0). Pooled linearized rate of late mortality was 1.66%/pt-yr (95% CI 1.34-2.07) with linearized rate of re-operation of 1.62%/pt-yr (95% CI 1.24-2.05). Perioperative results of extended arch procedures are encouraging. Further follow-up is required to see if long-term complications are reduced with these emerging techniques. The proposed classification system will facilitate future comparison of short- and long-term results of different techniques of extended arch repair for ATAAD. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Relation between calcium burden, echocardiographic stent frame eccentricity and paravalvular leakage after corevalve transcatheter aortic valve implantation.

    PubMed

    Di Martino, Luigi F M; Soliman, Osama I I; van Gils, Lennart; Vletter, Wim B; Van Mieghem, Nicolas M; Ren, Ben; Galema, Tjebbe W; Schultz, Carl; de Jaegere, Peter P T; Di Biase, Matteo; Geleijnse, Marcel L

    2017-06-01

    Paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) is a complication with potentially severe consequences. The relation between native aortic root calcium burden, stent frame eccentricity and PVL was not studied before. Two-hundred-and-twenty-three consecutive patients with severe aortic stenosis who underwent TAVI with a Medtronic CoreValve System© and who had available pre-discharge transthoracic echocardiography were studied. Echocardiographic stent inflow frame eccentricity was defined as major-minor diameter in a short-axis view >2 mm. PVL was scored according to the updated Valve Academic Research Consortium (VARC-2) recommendations. In a subgroup of 162 (73%) patients, the calcium Agatston score was available. Stent frame eccentricity was seen in 77 (35%) of patients. The correlation between the Agatston score and stent frame eccentricity was significant (ρ = 0.241, P = 0.003). Paravalvular leakage was absent in 91 cases (41%), mild in 67 (30%), moderate in 51 (23%), and severe in 14 (6%) cases. The correlation between stent frame eccentricity and PVL severity was significant (ρ = 0.525, P < 0.0001). There was a relation between particular eccentric stent frame shapes and the site of PVL. Calcification of the aortic annulus is associated with a subsequent eccentric shape of the CoreValve prosthesis. This eccentric shape results in more PVL, with the localization of PVL related to the shape of stent frame eccentricity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  2. Concurrent Angioplasty Balloon Placement for Stent Delivery through Jugular Venous Bulb for Treating Cerebral Venous Sinus Stenosis. Technical Report.

    PubMed

    Qureshi, Adnan I; Khan, Asif A; Capistrant, Rachel; Qureshi, Mushtaq H; Xie, Kevin; Suri, M Fareed K

    2016-10-01

    To report upon technique of concurrent placement of angioplasty balloon at the internal jugular vein and sigmoid venous sinus junction to facilitate stent delivery in two patients in whom stent delivery past the jugular bulb was not possible. A 21-year-old woman and a 41-year-old woman with worsening headaches, visual obscuration or diplopia were treated for pseudotumor cerebri associated with transverse venous stenosis. Both patients had undergone primary angioplasty, which resulted in improvement in clinical symptoms followed by the recurrence of symptoms with restenosis at the site of angioplasty. After multiple attempts at stent delivery through jugular venous bulb were unsuccessful, a second guide catheter was placed in the ipsilateral internal jugular vein through contralateral femoral venous approach. A 6 mm × 20 mm (left) or 5 × 15 mm (right) angioplasty balloon was placed across the internal jugular vein and sigmoid sinus junction and partially inflated until the inflation and relative straightening of the junction was observed. In both patients, the internal jugular vein and sigmoid sinus junction was successfully traversed by the stent delivery system in a parallel alignment to inflated balloon. Balloon mounted stent was deployed at the site of restenosis with near complete resolution of lumen narrowing delivery and improvement in clinical symptoms. We report a technique for realignment and diameter change with concurrent placement and partial inflation of angioplasty balloon at the jugular venous bulb to facilitate stent delivery into the sigmoid and transverse venous sinuses in circumstances where multiple attempts at stent delivery are unsuccessful.

  3. Mechanical Characteristics of Composite Knitted Stents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokuda, Takanori, E-mail: tkdtknr@gmail.com; Shomura, Yuzo; Tanigawa, Noboru

    2009-09-15

    We used metal wires and fibers to fabricate a composite knitted stent and then compare the mechanical characteristics of this stent with those of a pure metallic stent of the same construction in order to develop a stent that offers a comparable degree of expandability as metallic stents but can be used for highly curved lesions that cannot be treated using metallic stents. We fabricated two types of composite knitted stent (N-Z stents), using nitinol wire with a diameter of 0.12 mm and polypara-phenylene-benzobisoxazole (PBO) multifilament fiber (Zyron AS; Toyobo, Osaka, Japan). Stents were knitted into a cylindrical shape usingmore » the same textile pattern as a Strecker stent. Two loop lengths (L) of nitinol wire were used in the N-Z stents: L = 1.84 mm (N-Z stent L = 1.84) and L = 2.08 mm (N-Z stent L = 2.08). For the sake of comparison, we fabricated a metallic stent of nitinol using the same textile pattern (N-N stent L = 1.92). We applied a radial compression force diametrically to each stent and applied a bending force diametrically at the free end of a stent with one end fixed in order to evaluate the relationship between stent elasticity and load values. In addition, we macroscopically evaluated the generation of kinks when the stent was bent 180{sup o}. The radial compressive force when the stent diameter was reduced by 53% was 6.44 N in the case of N-Z stent L = 1.84, 6.14 N in the case of N-Z stent L = 2.08, and 4.96 N in the case of N-N stent L = 1.92 mm. The composite stent had a radial compressive force higher than that of a metallic stent. The restoring force to longitudinal direction at a 90{sup o} bending angle was 0.005 N for N-Z stent L = 1.84, 0.003 N for N-Z stent L = 2.08, and 0.034 N for N-N stent L = 1.92. The restoring force of the composite stent was significantly lower. Finally, the composite stent generated no definitive kinks at a bending angle of 180{sup o}, regardless of loop length. However, the N-N stent clearly produced kinks, causing blockage of the inner cavity. In conclusion, the use of a metal and fiber composite in the construction of a knitted stent ensures an expansion performance comparable to that of metallic stents, while providing better kink resistance.« less

  4. A comparison of outcomes between a lumen-apposing metal stent with electrocautery-enhanced delivery system and a bi-flanged metal stent for drainage of walled-off pancreatic necrosis.

    PubMed

    Bekkali, Noor L H; Nayar, Manu K; Leeds, John S; Charnley, Richard M; Huggett, Matthew T; Oppong, Kofi W

    2017-12-01

     Bi-flanged metal stents (BFMS) have shown promise in the drainage of walled-off pancreatic necrosis (WON), but their placement requires multiple steps and the use of other devices. More recently, a novel device consisting of a combined lumen-apposing metal stent (LAMS) and electrocautery-enhanced delivery system has been introduced. The aim of this study was to compare the placement and outcomes of the two devices.  This was a retrospective review of consecutive patients undergoing endoscopic ultrasound-guided placement of BFMS or LAMS for drainage of symptomatic WON. Data from procedures between October 2012 and December 2016 were taken from a prospectively maintained database. We compared technical and clinical success, procedure time, costs, and composite end point of significant events (adverse events, stent migration, additional percutaneous drainage) between BFMS and LAMS.  72 consecutive patients underwent placement of BFMS (40 patients, 44 stents) or LAMS (32 patients, 33 stents). Technical success was 91 % for BFMS and 97 % for LAMS. Clinical success was 65 % vs. 78 %, respectively. Median in-room procedure time was significantly shorter in the LAMS group (45 minutes [range 30 - 80]) than in the BFMS group (62.5 minutes [range 35 - 135]; P  < 0.001) and fewer direct endoscopic necrosectomies (DEN) were performed (median 1 [0 - 2.0] vs. 2 [0 - 3.7], respectively; P  = 0.005). If only inpatients were considered (35 BFMS and 19 LAMS), there was no significant difference in DEN 2 (range 0 - 11) and 2 (range 0 - 8), respectively. The composite end point of 32 % vs. 24 % was not significantly different. Median procedural costs for all patients with successful stent placement for WON treatment was €4427 (range 1630 - 12 926) for BFMS vs. €3500 (range 2509 - 13 393) for LAMS ( P  = 0.10).  LAMS was superior to BFMS in terms of procedure time, with comparable adverse events, success, and costs.

  5. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    PubMed

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  6. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer.

    PubMed

    Korsager, Anne Sofie; Carl, Jesper; Østergaard, Lasse Riis

    2013-06-01

    In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  7. Aortocoronary dissection with acute left main artery occlusion: successful treatment with emergent stenting.

    PubMed

    Wykrzykowska, Joanna J; Carrozza, Joseph; Laham, Roger J

    2006-08-01

    Iatrogenic aortocoronary dissection is a rare but devastating complication of percutaneous coronary interventions and cardiac surgery, with a mortality rate up to 35%. Of the type-A dissections in the International Registry of Aortic Dissections (IRAD), 27% were caused by coronary interventions. The mechanism involves an initial dissection in the coronary artery, which then propagates in a retrograde fashion past the sinuses of Valsalva, often several centimeters beyond the aortic valve. With the advent of complex interventions such as left main stent implantation, revascularization of chronic total occlusions and mechanical thrombectomy, this complication may become more prevalent. Here we present a unique case of percutaneous coronary intervention (PCI) of the left circumflex (LCx) artery complicated by a left main coronary dissection that propagated approximately 8 cm into the ascending aorta and caused abrupt left main coronary artery occlusion and hemodynamic collapse. Rescue of the left main artery and sealing of the aortic dissection with stabilization of the patient was possible with rapid ostial left main artery stenting.

  8. Control of Fibrinogen Assembly by Changing a Polarity of Surfaces

    NASA Astrophysics Data System (ADS)

    Koo, Jaseung; Liu, Ying; Snow, Sara; Rambhia, Pooja; Koga, Tadanori; Rafailovich, Miriam; Galanakis, Dennis

    2009-03-01

    Thrombogenesis causes various problems associated with an interruption in the blood flow (e.g., myocardial and cerebral infarction), and a hindrance to use of blood-contact vascular biomaterials (e.g., hemodialysis and cardiopulmonary bypass) with long-term patency since undesired adsorption of blood components occurs on vessels or biomaterials, such as surface-induced thrombosis. we showed that this clotting procedure can be occurred on hydrophobic polymeric surfaces without thrombin cleavage. However, the fibrinogen fibers were not formed on the polar surface such as spun-cast polymer film with pyridine and phenol groups. We also found that αC domains play an important role in initiation of polymerization on surface. Therefore, molecular association was inhibited on the polar surfaces due to confinement of αC chains on the surfaces. These findings were directly applied to stent surface modification. The commercial stent consist of Co-Cr alloy forms undesired fiber formation. However, PS-r-PVPh (13% phenol) coated stent surfaces completely prevent fiber formation.

  9. Surface modification of metallic cardiovascular stents by strongly adhering aliphatic polyester coatings.

    PubMed

    Jérôme, Christine; Aqil, Abdelhafid; Voccia, Samuël; Labaye, David-Emmanuel; Maquet, Véronique; Gautier, Sandrine; Bertrand, Olivier F; Jérôme, Robert

    2006-03-01

    This article reports on a novel two-step strategy for the coating of cardiovascular stents by strongly adhering biocompatible and biodegradable aliphatic polyesters. First, a precoating of poly(ethylacrylate) (PEA) was electrografted onto the metallic substrate by cathodic reduction of the parent monomer in dimethylformamide (DMF). The electrodeposition of PEA, in a good solvent of it, was confirmed by both Infra-red and Raman spectroscopies. The pendant ester groups of PEA were then chemically reduced into aluminum alkoxides, able to initiate the ring-opening polymerization (ROP) of either D,L-lactide (LA) or epsilon-caprolactone (CL). Growth of biodegradable PLA or PCL coatings from the adhering precoating was confirmed by both Infra-red and Raman spectroscopies, and directly observed by scanning electron microscopy (SEM). This type of coating can act as an anchoring layer for the subsequent casting of drug-loaded polyester films allowing the controlled release of antiproliferative agents for the treatment of in-stent restenosis. (c) 2005 Wiley Periodicals, Inc.

  10. Unconstrained Recovery Characterization of Shape-Memory Polymer Networks for Cardiovascular Applications

    PubMed Central

    Yakacki, Christopher M.; Shandas, Robin; Lanning, Craig; Rech, Bryan; Eckstein, Alex; Gall, Ken

    2009-01-01

    Shape-memory materials have been proposed in biomedical device design due to their ability to facilitate minimally invasive surgery and recover to a predetermined shape in-vivo. Use of the shape-memory effect in polymers is proposed for cardiovascular stent interventions to reduce the catheter size for delivery and offer highly controlled and tailored deployment at body temperature. Shape-memory polymer networks were synthesized via photopolymerization of tert-butyl acrylate and poly (ethylene glycol) dimethacrylate to provide precise control over the thermomechanical response of the system. The free recovery response of the polymer stents at body temperature was studied as a function of glass transition temperature (Tg), crosslink density, geometrical perforation, and deformation temperature, all of which can be independently controlled. Room temperature storage of the stents was shown to be highly dependent on Tg and crosslink density. The pressurized response of the stents is also demonstrated to depend on crosslink density. This polymer system exhibits a wide range of shape-memory and thermomechanical responses to adapt and meet specific needs of minimally invasive cardiovascular devices. PMID:17296222

  11. Bench-top Comparison of Physical Properties of 4 Commercially-Available Self-Expanding Intracranial Stents

    PubMed Central

    Cho, Su-hee; Jo, Won-il; Jo, Ye-eun; Yang, Ku Hyun; Park, Jung Cheol

    2017-01-01

    Purpose To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. Materials and Methods Four different types of stents that are currently being used for cerebral aneurysm embolization were prepared (two stents per type). Two were laser-cut stents (Neuroform and Enterprise) and two were braided from a single nitinol wire (LEO and LVIS stents). All were subjected to quantitative measurements of stent size, pore density, metal coverage, the force needed to load, push, and deploy the stent, radial force on deployment, surface roughness, and corrosion resistance. Results Compared to their nominal diameters, all stents had greater diameters after deployment. The length generally decreased after deployment. This was particularly marked in the braided stents. The braided stents also had higher pore densities than the laser-cut stents. Metal coverage was highest in the LEO stent (14%) and lowest in the Enterprise stent (5%). The LIVS stent had the highest microcatheter loading force (81.5 gf). The LEO stent had the highest passage force (55.0 gf) and deployment force (78.9 gf). The LVIS and LEO stents had the highest perpendicular (37.1 gf) and circumferential (178.4 gf) radial forces, respectively. The Enterprise stent had the roughest stent wire, followed by the LVIS, LEO, and Neuroform stents. Conclusion The four neurovascular stent types differed in terms of morphological and physical characteristics. An understanding of this diversity may help to decide which stent is most suitable for specific clinical situations. PMID:28316867

  12. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    PubMed Central

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  13. Fabrication of cylindrical micro-parts using synchronous rotary scan-projection lithography and chemical etching

    NASA Astrophysics Data System (ADS)

    Ito, Kaiki; Suzuki, Yuta; Horiuchi, Toshiyuki

    2017-07-01

    Lithographical patterning on the surface of a fine pipe with a thin wall is required for fabricating three-dimensional micro-parts. For this reason, a new exposure system for printing patterns on a cylindrical pipe by synchronous rotary scan-projection exposure was developed. Using the exposure system, stent-like resist patterns with a width of 251 μm were printed on a surface of stainless-steel pipe with an outer diameter of 2 mm. The exposure time was 30 s. Next, the patterned pipe was chemically etched. As a result, a stent-like mesh pipe with a line width of 230 μm was fabricated. It was demonstrated that the new method had a potential to be applied to fabrications of stent and other cylindrical micro-parts.

  14. Tracking delivery of a drug surrogate in the porcine heart using photoacoustic imaging and spectroscopy

    NASA Astrophysics Data System (ADS)

    Furdella, Kenneth J.; Witte, Russell S.; Vande Geest, Jonathan P.

    2017-04-01

    Although the drug-eluting stent (DES) has dramatically reduced the rate of coronary restenosis, it still occurs in up to 20% of patients with a DES. Monitoring drug delivery could be one way to decrease restenosis rates. We demonstrate real-time photoacoustic imaging and spectroscopy (PAIS) using a wavelength-tunable visible laser and clinical ultrasound scanner to track cardiac drug delivery. The photoacoustic signal was initially calibrated using porcine myocardial samples soaked with a known concentration of a drug surrogate (DiI). Next, an in situ coronary artery was perfused with DiI for 20 min and imaged to monitor dye transport in the tissue. Finally, a partially DiI-coated stent was inserted into the porcine brachiocephalic trunk for imaging. The photoacoustic signal was proportional to the DiI concentration between 2.4 and 120 μg/ml, and the dye was detected over 1.5 mm from the targeted coronary vessel. Photoacoustic imaging was also able to differentiate the DiI-coated portion of the stent from the uncoated region. These results suggest that PAIS can track drug delivery to cardiac tissue and detect drugs loaded onto a stent with sub-mm precision. Future work using PAIS may help improve DES design and reduce the probability of restenosis.

  15. Endoscopic approach for management of biliary strictures in liver transplant recipients: A systematic review and meta-analysis

    PubMed Central

    Aparício, Dayse Pereira da Silva; Otoch, José Pinhata; Montero, Edna Frasson de Souza; Artifon, Everson Luiz de Almeida

    2016-01-01

    The most common biliary complication after liver transplantation is anastomotic stricture (AS) and it can occur isolated or in combination with other complications. Liver graft from a cadaveric donor or a living donor has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. Endoscopic treatment using balloon dilation and insertion of biliary stents by endoscopic retrograde cholangiopancreatography (ERCP) is the initial approach to these complications. Aim The aim of this article is to compare different endoscopic techniques to treat post-liver transplantation biliary strictures. Methods The search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases through June 2015. A total of 1100 articles were retrieved. Ten clinical trials were analyzed, and seven were included in the meta-analysis. Conclusions The endoscopic treatment of AS was equally effective when compared the use of fully covered self-expandable metal stents (FCSEMS) vs. plastic stents, but the use of FCSEMS was associated with a lower complication risk. The treatment of AS with balloon dilation or balloon dilation associated with plastic stents presented similar results. Deceased donor liver transplantation reduced the risk of biliary stenosis and the endoscopic treatment in these patients was more effective when compared with Living donor liver transplantation. PMID:29026597

  16. Stent grafts for the treatment of abdominal aortic aneurysms.

    PubMed

    Diethrich, Edward B

    2003-01-01

    Stent grafting for treatment of abdominal aortic aneurysms (AAAs) has been a major advance in endovascular surgery. Initial success with the original endoluminal stent graft encouraged worldwide study of the technology. In the United States, the Food and Drug Administration (FDA) insisted on considerable experience with the devices before approval because of early problems with device rupture, stent fracture, fabric perforation, graft migration, and modular separation. Complications associated with the endovascular graft technology led many to recommend its use only in patients who were considered at "high risk" for the standard, open procedure. Further study and device improvements have led to results that indicate the procedure has the potential to reduce operating time and blood loss and shorten intensive care unit and hospital stays compared with open surgical intervention. At present, there are three FDA-approved devices available for use, and a fourth is expected in 2003. The ultimate decision by the individual practitioner or the institutional team regarding which patients should be treated with endovascular technology is still not entirely straightforward. Patient selection should be based on vascular anatomy, the availability of a suitable device, the patient's desire for a minimally invasive procedure, and a commitment to what is likely to be a lifetime of device surveillance.

  17. Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.

    PubMed

    Krievins, Dainis; Krämer, Albrecht; Savlovskis, Janis; Oszkinis, Georgij; Debus, E Sebastian; Oberhuber, Alexander; Zarins, Christopher K

    2018-06-01

    To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double "D-shaped" stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, and blood loss ≥1000 mL), and clinical success (freedom from procedure-related death, type I/III endoleak, migration, thrombosis, and reintervention). Endografts were successfully implanted in 89 (99%) patients; the single failure was due to delivery system malfunction before insertion in the early-generation device. One (1%) patient died and 4 patients underwent reinterventions (1 type I endoleak, 2 iliac limb stenoses, and 1 endograft occlusion) within the first 30 days. During a median follow-up of 12.5 months (range 11.5-50.9), there were no aneurysm ruptures, surgical conversions, or AAA-related deaths. The cumulative MAE rates were 3% (3/89) at 6 months and 7% (6/89) at 1 year. Two patients underwent coil embolization of type II endoleaks at 6.5 months and 2.2 years, respectively. Clinical success was 94% (84/89) at 30 days, 98% (85/87) at 6 months, and 99% (82/83) at 1 year. Early results suggest that properly selected AAA patients can be safely treated using the Altura Endograft System with favorable midterm outcome. Thus, further clinical investigation is warranted to evaluate the role of this device in the treatment of AAA.

  18. Malignant Ureteral Obstruction: Functional Duration of Metallic versus Polymeric Ureteral Stents

    PubMed Central

    Chow, Po-Ming; Chiang, I-Ni; Chen, Chia-Yen; Huang, Kuo-How; Hsu, Jui-Shan; Wang, Shuo-Meng; Lee, Yuan-Ju; Yu, Hong-Jeng; Pu, Yeong-Shiau; Huang, Chao-Yuan

    2015-01-01

    Background Ureteral obstruction caused by extrinsic compression is often associated with intra-abdominal cancers. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. Novel designs of ureteral stents made of different materials have been invented to achieve better drainage. In this study, we described the functional outcomes of a Resonance metallic ureteral stent (Cook Medical, Bloomington, Indiana, USA) in patients with malignant ureteral obstruction and compare the functional duration of Resonance stents with regular polymeric stents in the same cohort. Methods Cancer patients who received polymeric stents and subsequent Resonance stents for ureteral obstruction between July 2009 and November 2012 were included in a chart review. Stent failure was detected by clinical symptoms, imaging studies, and renal function tests. The functional durations of each stent were calculated, and possible factors affecting stent patency were investigated. Results A total of 50 stents were successfully inserted into 50 ureteral units in 42 patients with malignant ureteral obstruction. There were 7 antegrade stents and 43 retrograde stents. There were no major complications. Stent-related symptoms were similar in both kinds of stents. After polymeric stents were replaced with Resonance metallic stents, hydronephrosis subsided or remained stable in 90% (45/50) of the ureteral units. Serum creatinine decreased or remained stable in 90% (38/42) of these patients. The Resonance stent exhibited a mean increase in functional duration of 4 months compared with the polymeric stents (p<0.0001), and 50% (25/50) of the Resonance stents exhibited a significant increase in functional duration (more than 3 months). Pre-operative serum creatinine < 2 was associated with a substantial increase in stent duration. Conclusions Resonance stents are effective and safe in relieving malignant ureteral obstructions after polymeric stents failure. Resonance stents can provide a longer functional duration than polymeric stents and should be offered as an option for internal drainage. PMID:26267140

  19. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    PubMed

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  20. The INNOVATION Trial: four-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System for endovascular repair.

    PubMed

    Pratesi, Giovanni; Pratesi, Carlo; Chiesa, Roberto; Coppi, Gioacchino; Scheinert, Dierk; Brunkwall, Jan S; van der Meulen, Stefaan; Torsello, Giovanni

    2017-10-01

    This paper reports the 4-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System (Cordis Corp., Milpitas, CA, USA), an ultra-low-profile device for the treatment of abdominal aortic aneurysms. The INNOVATION Trial is the prospective, first-in-human, multicenter trial to evaluate the safety and effectiveness of the INCRAFT® System. Patients underwent annual clinical and computed tomography angiography examination as part of the study protocol. The INCRAFT® AAA Stent-Graft System is a customizable tri-modular design, with an ultra-low profile (14-Fr) delivery system. Patient were treated under approved protocol, the prescribed clinical and imaging follow-up at annually through 5 years. Results analyzed and adjudicated by a clinical events committee, independent core laboratory, and a data safety and monitoring board. This manuscript reports results through 4 years of follow-up. A total of 60 patients were enrolled in the trial, all of whom were successfully treated. Follow-up rates at 1 and 4 years were 93% (56/60) and 85% (51/60), respectively. All-cause mortality at 4 years was 17.6% and no death was AAA-, device-, or procedure-related. The secondary reintervention rate at 1 year was 4.6%, primarily the result of stent thrombosis. In total, 10 patients required 13 post-procedure interventions within 4-years of follow-up (2 to repair a type I endoleak, 4 to repair a type II endoleak, 1 for stent thrombosis, 1 for renal stenosis, 1 for aneurysm enlargement, 2 for limb migration and 2 for prosthesis stenosis or occlusion). There were 4 cases (10%) of aneurysm enlargement reported at the 4 year follow-up. At 4 years, 38 out of 39 patients were free from type I and III endoleaks. There were no proximal type I or type III endoleaks at 4-year follow-up. Core laboratory evaluation of the postoperative imaging studies indicated absence of endograft migration while a single fracture was demonstrated without any clinical sequelae. The INCRAFT® AAA Stent-Graft System provides a minimally invasive and durable solution for patients undergoing EVAR that has been associated with a low frequency of device-related events through 4 years of follow-up.

  1. Financial impact of coronary stenting in emergency for acute coronary syndromes.

    PubMed

    Nidegger, Delphine; Metz, Damien; Vacter, Christophe; Tassan-Mangina, Sophie; Deschildre, Alain; Gawron, Michel; Bourgeois, Jacqueline

    2009-05-01

    Since the prospective payment system, health institutions have only specific payments for the emergency care in the emergency room. The direct urgent admissions in coronary care units for acute coronary syndrome (ACS) do not collect this complementary refund. For the patient's stay, hospital is remunerated with fixed national prices which are similar even in case of emergent or planed coronary revascularization when realized. To analyze and compare the financial impact between emergent and planed coronary stenting in the setting of ACS. This retrospective study was based on patients suffering from ACS who experienced emergent coronary stenting during the year 2005. On 154 patients, 127 were age-, sex- and diagnosis-related group (called "groupe homogène de malades" in the French Health Care system)-matched with 127 suffering from same ACS but with planed "ad hoc" coronary stenting. The overall charges (medical and paramedical team, pharmacy, biology, implantable coronary devices, radiology) were compared between the two groups. Mean stay duration was 6.7 days and did not differ between the two groups. Mean financial retributions were significantly higher in the emergent group (7338 euro [6831-7846] IC95 vs 6509 euro [5994-7023]; p=0,02) but with a much more raised consumption (6810 euro [6283-7336] vs 5223 euro [4632-5814]; p=0,001). This overcost was due especially to drugs and biological expenses. The hospitalization payments did not cover the overall expenses for 25% of the patients' stays (N=64) among whom 39 have had emergent coronary stenting (30.7%, p=0.04). Among the different GHM, the most important difference was observed in non-STEMI without complication with a negative receipts/costs ratio for 37.8% of the stay with coronary stenting in emergency. The application of the recent guidelines for coronary revascularization in the management of ACS represents a financial venture for hospital institutions. The engaged charges for emergent coronary stenting are covered with difficulties contrary to planed revascularization.

  2. Direct comparison of coronary bare metal vs. drug-eluting stents: same platform, different mechanics?

    PubMed

    Schmidt, Wolfram; Lanzer, Peter; Behrens, Peter; Brandt-Wunderlich, Christoph; Öner, Alper; Ince, Hüseyin; Schmitz, Klaus-Peter; Grabow, Niels

    2018-01-08

    Drug-eluting stents (DES) compared to bare metal stents (BMS) have shown superior clinical performance, but are considered less suitable in complex cases. Most studies do not distinguish between DES and BMS with respect to their mechanical performance. The objective was to obtain mechanical parameters for direct comparison of BMS and DES. In vitro bench tests evaluated crimped stent profiles, crossability in stenosis models, elastic recoil, bending stiffness (crimped and expanded), and scaffolding properties. The study included five pairs of BMS and DES each with the same stent platforms (all n = 5; PRO-Kinetic Energy, Orsiro: BIOTRONIK AG, Bülach, Switzerland; MULTI-LINK 8, XIENCE Xpedition: Abbott Vascular, Temecula, CA; REBEL Monorail, Promus PREMIER, Boston Scientific, Marlborough, MA; Integrity, Resolute Integrity, Medtronic, Minneapolis, MN; Kaname, Ultimaster: Terumo Corporation, Tokyo, Japan). Statistical analysis used pooled variance t tests for pairwise comparison of BMS with DES. Crimped profiles in BMS groups ranged from 0.97 ± 0.01 mm (PRO-Kinetic Energy) to 1.13 ± 0.01 mm (Kaname) and in DES groups from 1.02 ± 0.01 mm (Orsiro) to 1.13 ± 0.01 mm (Ultimaster). Crossability was best for low profile stent systems. Elastic recoil ranged from 4.07 ± 0.22% (Orsiro) to 5.87 ± 0.54% (REBEL Monorail) including both BMS and DES. The bending stiffness of crimped and expanded stents showed no systematic differences between BMS and DES neither did the scaffolding. Based on in vitro measurements BMS appear superior to DES in some aspects of mechanical performance, yet the differences are small and not class uniform. The data provide assistance in selecting the optimal system for treatment and assessment of new generations of bioresorbable scaffolds. not applicable.

  3. Comparative Case-Control analysis of a dedicated self-expanding Biolimus A9-eluting Bifurcation stent versus provisional or mandatory side branch intervention strategies in the treatment of coronary bifurcation lesions.

    PubMed

    Ohlow, Marc-Alexander; Farah, Ahmed; Richter, Stefan; El-Garhy, Mohamad; von Korn, Hubertus; Lauer, Bernward

    2017-07-01

    In a number of coronary bifurcation lesions, both the main vessel and the side branch (SB) need stent coverage. To analyze the procedural performance and the impact on radiation times (RT) and contrast medium consumption (CMC) of the Axxess™ stent system (Biosensors, Switzerland) treating de novo bifurcation lesions (DBL). One hundred and ten consecutive prospectively enrolled cases (Axxess Group) and 110 age, sex, and lesion location matched controls undergoing mandatory (Group A, n = 56) or provisional (Group B, n = 54) SB intervention were analyzed. Although more pre-dilatation was performed in the Axxess Group (92.7% vs. 46.4% [Group A] vs. 24.1% [Group B]), and more stents were used (2.4 vs. 1.2 vs. 1.05), RT and CMC were significantly lower in the Axxess Group [7.9 min/129 ml vs. 14.2 min/209 ml vs. 7.8 min/152 ml; P < 0.001]. Final Thrombolysis In Myocardial Infarction three flow in both branches was significantly more frequent in the Axxess Group (98.2% vs. 94.6% vs. 88.9%; P = 0.02), and post-interventional troponin T elevations were the lowest in the Axxess Group. Eighty one percent of the Axxess-stents could be implanted without technical difficulties. Difficult implantations procedures were mainly related to coronary anatomy. There was no safety concerns (cardiac death, stent-thrombosis) compared to controls. Cumulative 6-months MACE rates were 11% versus 23% versus 25%. TLR rates at 6-months were 5%, 18%, and 15%, respectively. Axxess bifurcation stent system procedures were associated with significantly less RT and CMC compared to conventional DBL therapy strategies. Difficult coronary anatomy may hinder successful implantation and a learning curve has to be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Effect of Antithrombotic Agents on the Patency of PTFE-Covered Stents in the Inferior Vena Cava: An Experimental Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makutani, Shiro; Kichikawa, Kimihiko; Uchida, Hideo

    Purpose: To evaluate the efficacy of antithrombotic agents in the prevention of stenosis of polytetrafluoroethylene (PTFE)-covered stents in the venous system. Methods: Spiral Z stents covered with PTFE (PTFE-covered stents) were placed in the inferior vena cava (IVC) of 34 dogs. Nineteen dogs, used as a control group, were sacrificed at 2, 4, and 12 weeks. Fifteen dogs, previously given antithrombotic agents [cilostazol (n= 5), warfarin potassium (n= 5), cilostazol plus warfarin potassium (n= 5)] were sacrificed at 4 weeks, and then examined angiographically and histopathologically. The effect of the antithrombotic agents was compared between groups. Results: The patency ratemore » of the antithrombotic agent group was 93% (14/15), which was higher than the control group rate of 63% (12/19). The mean stenosis rate of the patent stent at both ends and at the midportion was lower at 4 weeks in the antithrombotic agent group than in the control group. In particular, the mean stenosis rate in the cilostazol plus warfarin potassium group was significantly lower than the control group (Tukey's test, p < 0.05). The mean neointimal thickness of the patent stent at both ends and at the midportion was thinner at 4 weeks in the antithrombotic agent group than in the control group. In particular, the thickness of the neointima in the cilostazol plus warfarin potassium group was significantly decreased when compared with the control group (Tukey's test p < 0.05). At 4 weeks, endothelialization in the antithrombotic agent group tended to be almost identical to that in the control group. Conclusion: The present study suggests that administration of an antithrombotic agent is an effective way of preventing the stenosis induced by a neointimal thickening of PTFE-covered stents in the venous system.« less

  5. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    PubMed Central

    Guan, Ying; Wang, Lu; Lin, Jing; King, Martin W.

    2016-01-01

    Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft. PMID:28773781

  6. Finite Element Analysis of the Implantation Process of Overlapping Stents

    PubMed Central

    Xu, Jiang; Yang, Jie; Sohrabi, Salman; Zhou, Yihua; Liu, Yaling

    2017-01-01

    Overlapping stents are widely used in vascular stent surgeries. However, the rate of stent fractures (SF) and in-stent restenosis (ISR) after using overlapping stents is higher than that of single stent implantations. Published studies investigating the nature of overlapping stents rely primarily on medical images, which can only reveal the effect of the surgery without providing insights into how stent overlap influences the implantation process. In this paper, a finite element analysis of the overlapping stent implantation process was performed to study the interaction between overlapping stents. Four different cases, based on three typical stent overlap modes and two classical balloons, were investigated. The results showed that overlapping contact patterns among struts were edge-to-edge, edge-to-surface, and noncontact. These were mainly induced by the nonuniform deformation of the stent in the radial direction and stent tubular structures. Meanwhile, the results also revealed that the contact pressure was concentrated in the edge of overlapping struts. During the stent overlap process, the contact pattern was primarily edge-to-edge contact at the beginning and edge-to-surface contact as the contact pressure increased. The interactions between overlapping stents suggest that the failure of overlapping stents frequently occurs along stent edges, which agrees with the previous experimental research regarding the safety of overlapping stents. This paper also provides a fundamental understanding of the mechanical properties of overlapping stents. PMID:28690712

  7. Economic impact of angioplasty salvage techniques, with an emphasis on coronary stents: a method incorporating costs, revenues, clinical effectiveness and payer mix.

    PubMed

    Vaitkus, P T; Witmer, W T; Brandenburg, R G; Wells, S K; Zehnacker, J B

    1997-10-01

    We sought to broaden assessment of the economic impact of percutaneous transluminal coronary angioplasty (PTCA) revascularization salvage strategies by taking into account costs, revenues, the off-setting effects of prevented clinical complications and the effects of payer mix. Previous economic analyses of PTCA have focused on the direct costs of treatment but have not accounted either for associated revenues or for the ability of costly salvage techniques such as coronary stenting to reduce even costlier complications. Procedural costs, revenues and contribution margins (i.e., "profit") were measured for 765 consecutive PTCA cases to assess the economic impact of salvage techniques (prolonged heparin administration, thrombolysis, intracoronary stenting or use of perfusion balloon catheters) and clinical complications (myocardial infarction, coronary artery bypass graft surgery [CABG] or acute vessel closure with repeat PTCA). To assess the economic impact of various salvage techniques for failed PTCA, we used actual 1995 financial data as well as models of various mixes of fee-for-service, diagnosis-related group (DRG) and capitated payers. Under fee-for-service arrangements, most salvage techniques were profitable for the hospital. Stents were profitable at almost any level of clinical effectiveness. Under DRG-based systems, most salvage techniques such as stenting produced a financial loss to the hospital because one complication (CABG) remained profitable. Under capitated arrangements, stenting and other salvage modalities were profitable only if they were clinically effective in preventing complications in > 50% of cases in which they were used. The economic impact of PTCA salvage techniques depends on their clinical effectiveness, costs and revenues. In reimbursement systems dominated by DRG payers, salvage techniques are not rewarded, whereas complications are. Under capitated systems, the level of clinical effectiveness needed to achieve cost savings is probably not achievable in current practice. Further studies are needed to define equitable reimbursement schedules that will promote clinically effective practice.

  8. Magnetic navigation for thoracic aortic stent-graft deployment using ultrasound image guidance.

    PubMed

    Luo, Zhe; Cai, Junfeng; Wang, Su; Zhao, Qiang; Peters, Terry M; Gu, Lixu

    2013-03-01

    We propose a system for thoracic aortic stent-graft deployment that employs a magnetic tracking system (MTS) and intraoperative ultrasound (US). A preoperative plan is first performed using a general public utilities-accelerated cardiac modeling method to determine the target position of the stent-graft. During the surgery, an MTS is employed to track sensors embedded in the catheter, cannula, and the US probe, while a fiducial landmark based registration is used to map the patient's coordinate to the image coordinate. The surgical target is tracked in real time via a calibrated intraoperative US image. Under the guidance of the MTS integrated with the real-time US images, the stent-graft can be deployed to the target position without the use of ionizing radiation. This navigation approach was validated using both phantom and animal studies. In the phantom study, we demonstrate a US calibration accuracy of 1.5 ± 0.47 mm, and a deployment error of 1.4 ± 0.16 mm. In the animal study, we performed experiments on five porcine subjects and recorded fiducial, target, and deployment errors of 2.5 ± 0.32, 4.2 ± 0.78, and 2.43 ± 0.69 mm, respectively. These results demonstrate that delivery and deployment of thoracic stent-graft under MTS-guided navigation using US imaging is feasible and appropriate for clinical application.

  9. Stent placement for benign colonic stenosis: case report, review of the literature, and animal pilot data.

    PubMed

    Geiger, Timothy M; Miedema, Brent W; Tsereteli, Zurab; Sporn, Emanuel; Thaler, Klaus

    2008-10-01

    Permanent metal stent placement for malignant intestinal obstruction has been proven to be efficient. Temporary stents for benign conditions of the colon and rectum are less studied. This is a case study, review of the literature, and observation from an animal model on placement of stents in the colorectum for benign disease. A 55-year-old man presented with recurrent obstructions from a benign stricture of the distal sigmoid colon. After failed balloon dilations, a polyester coated stent was placed. The purpose of the stent was to improve symptoms and avoid surgery. The stent was expelled after 5 days. We conducted a literature review of stents placed for benign colorectal strictures and an animal study to evaluate stent migration. In the literature, there were 53 reports of uncovered metal stents, four covered metal stents, and six polyester stents. Patency rates were 71%, and migration rate was 43%. Migration occurred earlier with polyester stents (mean=8 days) versus covered (32 days) or uncovered metal stents (112 days). Severe complications were seen in 23% of patients. Four 45-kg pigs underwent rectosigmoid transection with a 21-mm anastomosis and endoscopic placement of a Polyflex stent. Two stents were secured with suture. Stents without fixation were expelled within 24 h of surgery. Stents with fixation were expelled between postoperative days 2 and 14. Stents for the treatment of benign colorectal strictures are safe, with comparable patency rates between stent types. Metal stents can cause severe complications. In a pig model, covered polyester stents tend to migrate early even with fixation. Further investigation needs to focus on new stent designs and/or better fixation.

  10. The diffusion of medical technology, local conditions, and technology re-invention: a comparative case study on coronary stenting.

    PubMed

    Hashimoto, Hideki; Noguchi, Haruko; Heidenreich, Paul; Saynina, Olga; Moreland, Abigail; Miyazaki, Shunichi; Ikeda, Shunya; Kaneko, Yoshihiro; Ikegami, Naoki

    2006-12-01

    Innovation of medical technology is a major driving force behind the increase in medical expenditures in developed countries. Previous studies identified that the diffusion of medical technology varied across countries according to the characteristics of regulatory policy and payment systems. Based on Roger's diffusion of innovation theory, this study purported to see how local practice norms, the evolving nature of diffusing technology, and local clinical needs in addition to differences in politico-economic systems would affect the process of innovation diffusion. Taking a case of coronary stenting, an innovative therapeutic technology in early 1990s, we provided a case study of hospital-based data between two teaching high-tech hospitals in Japan and the US for discussion. Stenting began to be widely used in both countries when complementary new technology modified its clinical efficacy, but the diffusion process still differed between the two hospitals due to (1) distinctive payment systems for hospitals and physicians, (2) practice norms in favor of percutaneous intervention rather than bypass surgery that was shaped by payment incentives and cultural attitudes, and (3) local patient's clinical characteristics that the technology had to be tailored for. The case study described the diffusion of stent technology as a dynamic process between patients, physicians, hospitals, health care systems, and technology under global and local conditions.

  11. Comparative study of CW, nanosecond- and femtosecond-pulsed laser microcutting of AZ31 magnesium alloy stents.

    PubMed

    Gökhan Demir, Ali; Previtali, Barbara

    2014-06-01

    Magnesium alloys constitute an interesting solution for cardiovascular stents due to their biocompatibility and biodegradability in human body. Laser microcutting is the industrially accepted method for stent manufacturing. However, the laser-material interaction should be well investigated to control the quality characteristics of the microcutting process that concern the surface roughness, chemical composition, and microstructure of the final device. Despite the recent developments in industrial laser systems, a universal laser source that can be manipulated flexibly in terms of process parameters is far from reality. Therefore, comparative studies are required to demonstrate processing capabilities. In particular, the laser pulse duration is a key factor determining the processing regime. This work approaches the laser microcutting of AZ31 Mg alloy from the perspective of a comparative study to evaluate the machining capabilities in continuous wave (CW), ns- and fs-pulsed regimes. Three industrial grade machining systems were compared to reach a benchmark in machining quality, productivity, and ease of postprocessing. The results confirmed that moving toward the ultrashort pulse domain the machining quality increases, but the need for postprocessing remains. The real advantage of ultrashort pulsed machining was the ease in postprocessing and maintaining geometrical integrity of the stent mesh after chemical etching. Resultantly, the overall production cycle time was shortest for fs-pulsed laser system, despite the fact that CW laser system provided highest cutting speed.

  12. Non-traumatic perforation of common hepatic duct: Case report and review of literature HP.

    PubMed

    Atwez, Abdelaziz; Augustine, Matthew; Nottingham, James M

    2017-01-01

    Non-traumatic biliary perforation other than the gallbladder is extremely rare and most commonly seen in children in association with congenital biliary anomalies. We present a rare case of choledocholithiasis that progressed to spontaneous perforation of the common hepatic duct probably from ischemic necrosis caused by impaction of large biliary stones. A 62-year-old female presented with diarrhea and jaundice. She was found to have two 2.5cm stones in the common hepatic duct. Stones could not be extracted by ERCP, and placement of biliary stent was done to restore patency. The patient was lost to follow up and returned after three months with a new onset of similar symptoms. At that time ERCP and a stent change were done without resolution of the symptoms. Patient then underwent an open exploration and was found to have a free perforation in the lateral aspect of the common hepatic duct just at the bifurcation of the right and left hepatic radicals. Through this perforation stones were both extracted and cholangiogram showed free flow with the distal biliary stent. The stent was nowhere near the site of perforation which appeared to be caused by pressure necrosis from the impacted stones. Impacted stones in the biliary tree need to be extracted to avoid pressure necrosis and spontaneous perforation. ERCP and stent placement should be used only as temporizing measures to manage the acute obstructive phase. Definitive surgical intervention must follow initial biliary decompression to extract the impacted biliary stones and avoid complications. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Recent advances in endovascular treatment of aortoiliac occlusive disease.

    PubMed

    Kavaliauskienė, Zana; Antuševas, Aleksandras; Kaupas, Rytis Stasys; Aleksynas, Nerijus

    2012-01-01

    The rate of endovascular interventions for iliac occlusive lesions is continuously growing. The evolution of the technology supporting these therapeutic measures improves the results of these interventions. We performed a review of the literature to report and appreciate short- and long-term results of endovascular stenting of iliac artery occlusive lesions. The Medline database was searched to identify all the studies reporting iliac artery stenting for aortoiliac occlusive disease (Trans Atlantic Inter-Society Consensus [TASC] type A, B, C, and D) from January 2006 to July 2012. The outcomes were technical success, long-term primary and secondary patency rates, early mortality, and complications. Technical success was achieved in 91% to 99% of patients as reported in all the analyzed articles. Early mortality was described in 5 studies and ranged from 0.7% to 3.6%. The most common complications were access site hematomas, distal embolization, pseudoaneurysms, and iliac artery ruptures. The complications were most often treated conservatively or using percutaneous techniques. The 5-year primary and secondary patency rates ranged from 63% to 88% and 86% to 93%, respectively; and the 10-year primary patency rates ranged from 68% to 83%. In this article, combined percutaneous endovascular iliac stenting and infrainguinal surgical reconstructions and new techniques in the treatment of iliac stent restenosis are discussed. Iliac stenting is a feasible, safe, and effective method for the treatment of iliac occlusive disease. Initial technical and clinical success rates are high; early mortality and complication rates are low. Long-term patency is comparable with that after bypass surgery.

  14. Endovascular stent grafting of thoracic aortic aneurysms: technological advancements provide an alternative to traditional surgical repair.

    PubMed

    Jones, Lauren E Beste

    2005-01-01

    The use of endovascular stent grafts is a leading technological advancement in the treatment of thoracic aortic aneurysms, and is being trialed in the United States as an alternative to medical management and traditional surgical repair. Aortic stent grafts, initially used only for abdominal aortic aneurysms, have been used for over 10 years in Europe and are currently under United States Food and Drug Administration investigation for the treatment of chronic and acute aortic aneurysms. Diseases of the thoracic aorta are often present in high-risk individuals, and, as a result, there is a high morbidity and mortality rate associated with both medical and surgical management of these patients. The development and refinement of endovascular approaches have the potential to decrease the need for traditional surgical repair, especially in high-risk populations such as the elderly and those with multiple comorbidities. Endovascular technology for thoracic repair has only been used in Europe for the last 10 years, with no long-term outcomes available; however, preliminary research demonstrates favorable early and midterm outcomes showing that endovascular stent graft placement to exclude the dilated, dissected, or ruptured aorta is both technically feasible and safe for patients. The article highlights the historical perspective of endovascular stent grafting as well as a description of patient selection, the operative procedure, benefits, risks, and unresolved issues pertaining to the procedure. A brief review of aneurysm and dissection pathophysiology and management is provided, as well as postoperative management for acute care nurses and recommendations for clinical practice.

  15. Comparison of 3 biodegradable polymer and durable polymer-based drug-eluting stents in all-comers (BIO-RESORT): rationale and study design of the randomized TWENTE III multicenter trial.

    PubMed

    Lam, Ming Kai; Sen, Hanim; Tandjung, Kenneth; van Houwelingen, K Gert; de Vries, Arie G; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; Löwik, Marije M; Linssen, Gerard C M; Ijzerman, Maarten J; van der Palen, Job; Doggen, Carine J M; von Birgelen, Clemens

    2014-04-01

    To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome. Copyright © 2014 The Authors. Published by Mosby, Inc. All rights reserved.

  16. Retreatment of recanalized aneurysms after Y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature.

    PubMed

    Kono, Kenichi; Shintani, Aki; Terada, Tomoaki

    2014-01-01

    It is necessary to consider possibility of recanalization and retreatment after coil embolization for cerebral aneurysms. There is concern that retreatment for recanalized aneurysms after Y-stent-assisted coil embolization may be difficult because of double stents, especially in Y-stents with double closed-cell stents owing to narrowed structures. However, no detailed reports of retreatment after Y-stent have been reported. Between July 2010 and June 2013, we treated four aneurysms with Y-stent-assisted coil embolization using Enterprise closed-cell stents. Recanalization occurred in one case (25%), and retreatment was performed. We easily navigated a microcatheter into the target portions of the aneurysm through the Y-stent and occluded the aneurysm with coils. Additionally, by systematically searching in PubMed, we found 105 cases of Y-stent-assisted coil embolization using Enterprise stents or Neuroform stents with more than 6 months of follow-up. Among them, retreatment was performed in 10 cases (9.5%). There were no significant differences in retreatment rates among different stent combinations (P=0.91; Fisher's exact test). In conclusion, navigation of a microcatheter into the aneurysm through the Y-stent with double Enterprise stents was feasible, and retreatment rates after Y-stent-assisted coiling may not depend on stent combinations.

  17. Newly designed plastic stent for endoscopic placement above the sphincter of Oddi in patients with malignant hilar biliary obstruction.

    PubMed

    Ishiwatari, Hirotoshi; Hayashi, Tsuyoshi; Ono, Michihiro; Sato, Tsutomu; Kato, Junji

    2013-05-01

    Plastic stent (PS) occlusion occurs as a result of bacterial adherence to the stent's inner wall. To retain the bacteriological barrier, placing a PS above the sphincter of Oddi ('inside stent') has been investigated. We designed a new PS (inside stent with thread [IT] stent) with attachable nylon thread for use as an inside stent and for easy retrieval. The present study evaluated the IT stent's technical feasibility and efficacy for malignant hilar biliary obstruction. A total of 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent placement of IT stents from August 2007 to February 2011. IT stents were placed across the strictures without sphincterotomy to achieve bilateral drainage. The overall technical success rate of the IT stent was 100% for one session. Multiple IT stents were inserted in 25 cases(two stents in 15 patients, three stents in 10 patients). No stent-related early complications occurred. The functional success rate was 92% (24/26). The rate of reintervention because of stent malfunction was 50% (13/26). In all 16 patients who underwent stent removal, IT stents were easily retrieved using the nylon thread. According to Kaplan-Meier analysis, the median stent patency period was 136 days. IT stents for endoscopic placement above the sphincter of Oddi can be used safely and effectively for malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  18. Predictors of early stent occlusion among plastic biliary stents.

    PubMed

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  19. The application of ink-jet technology for the coating and loading of drug-eluting stents.

    PubMed

    Tarcha, Peter J; Verlee, Donald; Hui, Ho Wah; Setesak, Jeff; Antohe, Bogdan; Radulescu, Delia; Wallace, David

    2007-10-01

    The combination of drugs with devices, where locally delivered drugs elute from the device, has demonstrated distinct advantages over therapies involving systemic or local drugs and devices administered separately. Drug-eluting stents are most notable. Ink jet technology offers unique advantages for the coating of very small medical devices with drugs and drug-coating combinations, especially in cases where the active pharmaceutical agent is very expensive to produce and wastage is to be minimized. For medical devices such as drug-containing stents, the advantages of ink-jet technology result from the controllable and reproducible nature of the droplets in the jet stream and the ability to direct the stream to exact locations on the device surfaces. Programmed target deliveries of 100 microg drug, a typical dose for a small stent, into cuvettes gave a standard deviation (SD) of dose of 0.6 microg. Jetting on coated, uncut stent tubes exhibited 100% capture efficiency with a 1.8 microg SD for a 137 microg dose. In preliminary studies, continuous jetting on stents can yield efficiencies up to 91% and coefficients of variation as low as 2%. These results indicate that ink-jet technology may provide significant improvement in drug loading efficiency over conventional coating methods.

  20. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    PubMed

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P < .001) was a risk factor for adverse events during stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  1. In vitro experiments of vessel wall apposition between the Enterprise and Enterprise 2 stents for treatment of cerebral aneurysms.

    PubMed

    Kono, Kenichi; Terada, Tomoaki

    2016-02-01

    A closed-cell stent called Enterprise has been used for stent-assisted coil embolization of cerebral aneurysms. The Enterprise stent tends to cause kinks and vessel wall malposition in curved vessels and may cause thromboembolic complications. We evaluated vessel wall apposition of a new closed-cell stent, Enterprise 2, compared with a previous Enterprise stent, using curved vascular silicone models. The Enterprise or Enterprise 2 stent was deployed in curved vascular models with various radii of approximately 5 to 10 mm. Stent deployment was performed 25 times in each stent. A push-pull technique was used to minimize incomplete wall apposition. To evaluate conformity of stents, gaps between a stent and a vessel wall were measured. The gap ratio (gap / a wall diameter) was 15 % ± 17 % (mean ± standard deviation) and 41 % ± 15 % with the Enterprise 2 stent and the Enterprise stent, respectively. Taking gap ratios and radii of vessel curvature into consideration, the Enterprise 2 stent had significantly better wall apposition than the Enterprise stent (p = 0.005). In the same radius of vessel curvature, the Enterprise 2 stent had approximately half of the gap compared with the Enterprise stent. There were no significant differences in vessel straightening effects between the two stents. The Enterprise 2 stent has better wall apposition in curved vessels than the Enterprise stent. The gap between a vessel wall and the Enterprise 2 stent is approximately half that of the Enterprise stent. However, gaps and kinks are still present in curved vessels with a small radius. Caution should be taken for kinks and malposition in acutely curved vessels, such as the siphon of the internal carotid artery.

  2. A newly designed big cup nitinol stent for gastric outlet obstruction

    PubMed Central

    Shi, Ding; Liao, Sheng-Hui; Geng, Jian-Ping

    2010-01-01

    AIM: To find out whether a newly designed big cup nitinol stent is suitable for treatment of patients with gastric outlet obstruction resulting from gastric cancer. METHODS: The new stent is composed of a proximal big cup segment (20 mm in length and 48-55 mm in diameter), a middle part (60 mm in length and 20 mm in diameter) covered by a polyethylene membrane and a distal sphericity (20 mm in length and 28 mm in diameter). Half of the proximal big cup segment is also covered by a polyethlene membrane, which is adjacent to the middle part of the stent. The stent is preloaded in a 6.0-mm-diameter introducer system. Thirteen patients with gastric outlet obstruction resulting from gastric cancer received the new stents under endoscopic and fluoroscopic guidance. RESULTS: Technical success was achieved in 12 of 13 (92.3%) patients. Among the 12 patients in whom endoscopic stent was placed successfully, the clinical success rate was 91.7% during a follow-up of average 6.5 mo. During the first month follow-up, the migration rate was 0%, recurrent obstruction 0% and gastric bleeding 8.3%. During the follow-up between 2-12 mo, no migration, recurrent obstruction and gastric bleeding occurred. CONCLUSION: The proximal big cup segment seems to be effective and promising for technical efficacy, clinical outcome, and preventing migration and tumor ingrowth and increasing the emptying rate of sinus ventriculi. PMID:20806440

  3. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    PubMed

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  4. Lumen-apposing covered self-expandable metal stents for short benign gastrointestinal strictures: a multicenter study.

    PubMed

    Yang, Dennis; Nieto, Jose M; Siddiqui, Ali; Riff, Brian P; DiMaio, Christopher J; Nagula, Satish; Ismail, Amr M; Ngamreungphong, Saowanee; Khashab, Mouen A; Wagh, Mihir S; Tzimas, Demetrios; Buscaglia, Jonathan M; Strand, Daniel S; Wang, Andrew Y; Chauhan, Shailendra S; Forsmark, Christopher E; Draganov, Peter V

    2017-04-01

    Background and study aim  Use of the fully covered self-expandable metal stent (SEMS) for benign luminal gastrointestinal (GI) stricture (BLGS) has been limited by the migration rate. The role of the lumen-apposing metal stent (LAMS) for BLGS is not well defined. We assessed the safety, feasibility, and efficacy of LAMS for the treatment of BLGS. Patients and methods  This was an observational, open-label, retrospective, single-arm, multicenter consecutive case series of patients undergoing LAMS placement for BLGS. Technical success was defined as successful placement of the LAMS. Short- and long-term clinical success rates were defined as symptom improvement/resolution with indwelling stent and after stent removal, respectively. All adverse events and additional interventions were recorded. Results  A total of 30 patients (mean age 51.6 years; 63.3 % women) underwent LAMS placement for GI strictures (83.9 % anastomotic). Median stricture diameter and length were 4.5 mm (range 2 - 10 mm) and 8 mm (range 5 - 10 mm), respectively. Technical success was achieved in 29 patients (96.7 %), with an adverse event rate of 13.3 %. The stent migration rate was 8.0 % (2/25) on follow-up endoscopy. Short-term clinical success was achieved in 90.0 % (27/30) at a median of 60 days (interquartile range [IQR] 40 - 90 days). Most patients (19/23; 82.6 %) experienced sustained symptom improvement/resolution without the need for additional interventions at a median follow-up of 100 days (IQR 60 - 139 days) after LAMS removal. Conclusion  This multicenter study demonstrated that LAMS placement represents a safe, feasible, and effective therapeutic option for patients with BLGS and is associated with a low stent migration rate. Our initial findings suggest that future prospective comparative studies are needed on the use of LAMS, endoscopic dilation, and conventional SEMS. . © Georg Thieme Verlag KG Stuttgart · New York.

  5. Self-Expandable Metal Stents for Persisting Esophageal Variceal Bleeding after Band Ligation or Injection-Therapy: A Retrospective Study.

    PubMed

    Müller, Martin; Seufferlein, Thomas; Perkhofer, Lukas; Wagner, Martin; Kleger, Alexander

    2015-01-01

    Despite a pronounced reduction of lethality rates due to upper gastrointestinal bleeding, esophageal variceal bleeding remains a challenge for the endoscopist and still accounts for a mortality rate of up to 40% within the first 6 weeks. A relevant proportion of patients with esophageal variceal bleeding remains refractory to standard therapy, thus making a call for additional tools to achieve hemostasis. Self-expandable metal stents (SEMS) incorporate such a tool. We evaluated a total number of 582 patients admitted to our endoscopy unit with the diagnosis "gastrointestinal bleeding" according to our documentation software between 2011 and 2014. 82 patients suffered from esophageal variceal bleeding, out of which 11 cases were refractory to standard therapy leading to SEMS application. Patients with esophageal malignancy, fistula, or stricture and a non-esophageal variceal bleeding source were excluded from the analysis. A retrospective analysis reporting a series of clinically relevant parameters in combination with bleeding control rates and adverse events was performed. The initial bleeding control rate after SEMS application was 100%. Despite this success, we observed a 27% mortality rate within the first 42 days. All of these patients died due to non-directly hemorrhage-associated reasons. The majority of patients exhibited an extensive demand of medical care with prolonged hospital stay. Common complications were hepatic decompensation, pulmonary infection and decline of renal function. Interestingly, we found in 7 out of 11 patients (63.6%) stent dislocation at time of control endoscopy 24 h after hemostasis or at time of stent removal. The presence of hiatal hernia did not affect obviously stent dislocation rates. Refractory patients had significantly longer hospitalization times compared to non-refractory patients. Self-expandable metal stents for esophageal variceal bleeding seem to be safe and efficient after failed standard therapy. Stent migration appeared to be a common incident that did not lead to reactivation of bleeding in any of our patients. SEMS should be considered a reasonable treatment option for refractory esophageal variceal bleeding after treatment failure of ligature and sclerotherapy and non-availability of or contraindication for other measures (e.g. TIPS).

  6. Early outcomes with a single-sided access endovascular stent.

    PubMed

    Hofmann, Michael; Pecoraro, Felice; Planer, David; Pfammatter, Thomas; Puippe, Gilbert; Bettex, Dominique; Veith, Frank J; Lachat, Mario; Chaykovska, Lyubov

    2018-03-27

    The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events (MAEs) including all-cause mortality, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, bowel ischemia, and procedural blood loss ≥1000 mL. Performance end points included successful delivery and deployment of the device, freedom from aneurysm growth ≥5 mm, type I or type III endoleak, stent graft occlusion, conversion to open surgery, rupture, and stent graft migration. In the FIM study, one conversion to open surgery with >1000 mL of blood loss was registered perioperatively. In the pivotal study, no perioperative MAE was registered. Overall, at 1-year follow-up, two deaths and one aneurysm growth unrelated to endoleak were registered. The results of both the FIM and pivotal studies demonstrated that 39 of 40 procedures were successful for delivery and deployment of the Horizon stent graft. No MAE was registered during the follow-up. The primary safety and performance end points were met in both studies. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Correction of Stent Distortion and Overhanging Stent Struts during Left Main Bifurcation Stenting by Selective Distal Stent Cell Re-Wiring: A Novel Guidewire Approach

    PubMed Central

    Sabbah, Mahmoud; Kadota, Kazushige; Fuku, Yasushi; Mitsudo, Kazuaki

    2015-01-01

    Stent malapposition and overhanging stent struts in front of the side branch (SB) ostium are not uncommon following bifurcation stenting that might lead to stent thrombosis. We herein present 2 cases, in which optical frequency domain imaging and intravascular ultrasound effectively revealed stent malapposition and overhanging struts inside the ostium of the SB following left main coronary artery stenting. Therefore, we introduced a novel technique for rectification of these incidental findings by selective SB re-wiring through the most distal stent cell with the adjunctive help of a double lumen microcatheter. PMID:27122906

  8. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    PubMed Central

    Kwon, Chang-Il; Lehman, Glen A.

    2016-01-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  9. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    PubMed

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  10. Endobiliary stent: marker for patient alignment in image-guided radiotherapy in pancreatic and periampullary cancers.

    PubMed

    Shukla, Pragya; Engineer, Reena; Chopra, Supriya; Shrivastava, Shyam Kishore

    2013-12-01

    The aim of this study was to analyse the possibility of using stent in pretreatment megavoltage computed tomography (MVCT) images with respect to that on planning kilovoltage computed tomography as tumour surrogate during matching for daily registration in cases of pancreatic and periampullary cancer treated on a TomoTherapy Hi-Art system. Planning CT and pretreatment MVCT of the first and then after every three fractions were transferred to a FocalSim workstation for ten patients. Planning CT of each patient was independently fused with each of the seven MVCT images of that patient. The stent was contoured on all of the eight images for each patient. The difference between the three co-ordinates of centre of mass (CM) of the stent on the planning CT and seven MVCT images was found. The difference between CM of the liver and stents on the planning CT as well as on the MVCT for all seven fractions was also calculated. The mean of these differences across all patients was calculated and analysed. The mean difference in planning and MVCT CMs for stents in the X, Y and Z directions was 0.13 cm (±0.4), 0.16 cm (±2.2) and 0.35 cm (±0.7), respectively. Average difference between CM of the liver and stent on the planning CT in the X, Y and Z directions was found to be 1.832 cm (±1.64), 5.34 cm (±1.33) and 0.54 cm (±0.26), respectively. Average difference between CM of the liver and CM of stent on the MVCT for that day in the X, Y and Z directions was found to be 1.93 cm (±1.5), 4.6 cm (±1.03) and 0.654 cm (±0.35), respectively. Endobiliary stents are stable tumour localisation surrogates and can be used to correct for interfraction target motion.

  11. Quantification of thrombus formation in malapposed coronary stents deployed in vitro through imaging analysis.

    PubMed

    Brown, Jonathan; O'Brien, Caroline C; Lopes, Augusto C; Kolandaivelu, Kumaran; Edelman, Elazer R

    2018-04-11

    Stent thrombosis is a major complication of coronary stent and scaffold intervention. While often unanticipated and lethal, its incidence is low making mechanistic examination difficult through clinical investigation alone. Thus, throughout the technological advancement of these devices, experimental models have been indispensable in furthering our understanding of device safety and efficacy. As we refine model systems to gain deeper insight into adverse events, it is equally important that we continue to refine our measurement methods. We used digital signal processing in an established flow loop model to investigate local flow effects due to geometric stent features and ultimately its relationship to thrombus formation. A new metric of clot distribution on each microCT slice termed normalized clot ratio was defined to quantify this distribution. Three under expanded coronary bare-metal stents were run in a flow loop model to induce clotting. Samples were then scanned in a MicroCT machine and digital signal processing methods applied to analyze geometric stent conformation and spatial clot formation. Results indicated that geometric stent features play a significant role in clotting patterns, specifically at a frequency of 0.6225 Hz corresponding to a geometric distance of 1.606 mm. The magnitude-squared coherence between geometric features and clot distribution was greater than 0.4 in all samples. In stents with poor wall apposition, ranging from 0.27 mm to 0.64 mm maximum malapposition (model of real-world heterogeneity), clots were found to have formed in between stent struts rather than directly adjacent to struts. This early work shows how the combination of tools in the areas of image processing and signal analysis can advance the resolution at which we are able to define thrombotic mechanisms in in vitro models, and ultimately, gain further insight into clinical performance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Protection or nonprotection in carotid stent angioplasty: the influence of interventional techniques on outcome data from the SPACE Trial.

    PubMed

    Jansen, Olav; Fiehler, Jens; Hartmann, Marius; Brückmann, Hartmut

    2009-03-01

    The use of protection devices (PDs) and stents with different cell designs in carotid artery stenting (CAS) is a subject of controversy, and no data on their benefit are available from independently controlled multi-center studies. We analyzed data from the prospective randomized SPACE trial, which included 563 patients randomized to CAS and treated per protocol. A total of 145 patients were treated with a PD and 418 without. Of the patients, 436 were treated with an open cell stent and 127 with a closed cell stent. Use of PDs and choice of device was chosen at the individual discretion of the interventionalist. The outcome event (OE) of the analysis (ipsilateral stroke or ipsilateral stroke death within 30 days) was reached in 26/418 patients (6.2%, 95% CI: 4.1 to 9.0%) in the nonprotection [corrected] group and in 12/145 (8.3%, 95% CI: 4.3 to 14.0%) patients in the protection [corrected] group (P=0.40). The OE rate was significantly lower in patients treated with a closed cell stent (5.6% [95% CI: 3.7 to 8.2%]) than in those treated with an open cell stent.(11.0%, 95% CI: 6.2 to 17.8%; P=0.029). Predilatation showed a tendency to but no significant reduction of OE rate. Overall, 49% of all OEs occurred directly periinterventionally, 10% during the navigation procedure and 41% postinterventionally, including 10% of hyperperfusion syndromes. Time point of the event was not influenced by the use of a PD. This secondary analysis of data from the SPACE trial does not support the need for a PD in CAS. Stent design seems to have an impact on the OE rate. Our analysis demonstrates that the choice of the interventional material may have an impact on the periprocedural complication rate in CAS and that the development of more specific stent systems for the treatment of carotid stenosis may reduce the complication rate significantly.

  13. [Brief history of interventional radiology].

    PubMed

    Tang, Zhenliang; Jia, Aiqin; Li, Luoyun; Li, Chunyu

    2014-05-01

    In 1923, angiography was first successively used for the human body. In 1953, a Swedish doctor Sven-Ivar Seldinger pioneered the Seldinger technique, which laid down the foundation of interventional radiology. In 1963, Charles Dotter first proposed the idea of interventional radiology. In 1964, Charles Dotter opened a new era of percutaneous angioplasty through accidental operation, marking the formation of interventional radiology. On this basis, the techniques of balloon catheter dilation and metal stent implantation was developed. Endovascular stent was proposed in 1969. In 1973, the percutaneous angioplasty has been a breakthrough with the emergence of soft double-lumen balloon catheter. Percutaneous coronary angioplasty is applied in 1977. Since the 1990s, balloon angioplasty relegated to secondary status with the emergence of metal stent. Currently, endovascular stent have entered a new stage with the emergence of temporary stent and stent grafts and biological stent. Transcatheter arterial embolization had been one of the most important basic techniques for interventional radiology since 1965, it had also been a corresponding development with the improvement of embolic agents and catheter technology for the treatment of diseases now. Transjugular intrahepatic portosystemic stent-shunt is a comprehensive interventional radiology technology since 1967, in which the biliary system can be reached through a jugular vein, and the improvement appeared with balloon expandable stent in 1986.Since 1972, non-vascular interventional techniques was another important branch of interventional radiology. Currently, it is applied in the diagnosis and treatment of many diseases of the internal organs like the pancreas, liver, kidney, spinal cord, Fallopian tubes, esophagus and other organs. In 1973, Chinese radiologist first conducted the angiography test. Interventional radiology was introduced into China in the 1980s, it was readily developed through the sponsoring of training class (1981) and academic conferences (1986). Along with the return of the overseas scholars, the gap in the interventional diagnosis and treatment technology between China and the world has been narrowing since the 1990s.

  14. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    PubMed

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  15. Treatment of central venous in-stent restenosis with repeat stent deployment in hemodialysis patients.

    PubMed

    Ronald, James; Davis, Bradley; Guevara, Carlos J; Pabon-Ramos, Waleska M; Smith, Tony P; Kim, Charles Y

    2017-05-15

    To report patency rates for stent deployment for treatment of in-stent stenosis of the central veins of the chest in hemodialysis patients. A retrospective analysis was performed on 29 patients who underwent 35 secondary percutaneous transluminal stent (PTS) deployments for in-stent stenosis within the central veins that were refractory to angioplasty and ipsilateral to a functioning hemodialysis access (in-stent PTS group). For comparison, patency data were acquired for 47 patients who underwent 78 successful percutaneous transluminal angioplasty (PTA) procedures for in-stent stenosis (in-stent PTA group) and 55 patients who underwent 55 stent deployments within native central vein stenosis refractory to angioplasty (native vein PTS group). The 3-, 6-, and 12-month primary lesion patency for the in-stent PTS group was 73%, 57%, and 32%, respectively. The 3-, 6-, and 12-month primary patency for the in-stent PTA group was 70%, 38%, and 17% and for the native vein PTS group was 78%, 57%, and 26%, which were similar to the in-stent PTS group (p = 0.20 and 0.41, respectively). The 3-, 6-, and 12-month secondary access patency was 91%, 73%, and 65% for the in-stent PTS group. Sub-analysis of the in-stent PTS group revealed no difference in primary (p = 0.93) or secondary patency rates (p = 0.27) of bare metal stents (n = 23) compared with stent grafts (n = 12). Stent deployment for central vein in-stent stenosis refractory to angioplasty was associated with reasonable patency rates, which were similar to in-stent PTA and native vein PTS.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Grenacher, L.; Stampfl, U.

    The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 {mu}m). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury,more » vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 {mu}m. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 {mu}m and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.« less

  17. Silver-nanoparticle-coated biliary stent inhibits bacterial adhesion in bacterial cholangitis in swine.

    PubMed

    Wen, Wei; Ma, Li-Mei; He, Wei; Tang, Xiao-Wei; Zhang, Yin; Wang, Xiang; Liu, Li; Fan, Zhi-Ning

    2016-02-01

    One of the major limitations of biliary stents is the stent occlusion, which is closely related to the over-growth of bacteria. This study aimed to evaluate the feasibility of a novel silver-nanoparticle-coated polyurethane (Ag/PU) stent in bacterial cholangitis model in swine. Ag/PU was designed by coating silver nanoparticles on polyurethane (PU) stent. Twenty-four healthy pigs with bacterial cholangitis using Ag/PU and PU stents were randomly divided into an Ag/PU stent group (n=12) and a PU stent group (n=12), respectively. The stents were inserted by standard endoscopic retrograde cholangiopancreatography. Laboratory assay was performed for white blood cell (WBC) count, alanine aminotransferase (ALT), interleukin-1beta (IL-1beta), tumor necrosis factor-alpha (TNF-alpha) at baseline time, 8 hours, 1, 2, 3, and 7 days after stent placements. The segment of bile duct containing the stent was examined histologically ex vivo. Implanted biliary stents were examined by a scan electron microscope. The amount of silver release was also measured in vitro. The number of inflammatory cells and level of ALT, IL-1beta and TNF-alpha were significantly lower in the Ag/PU stent group than in the PU stent group. Hyperplasia of the mucosa was more severe in the PU stent group than in the Ag/PU stent group. In contrast to the biofilm of bacteria on the PU stent, fewer bacteria adhered to the Ag/PU stent. PU biliary stents modified with silver nanoparticles are able to alleviate the inflammation of pigs with bacterial cholangitis. Silver-nanoparticle-coated stents are resistant to bacterial adhesion.

  18. Carotid artery stents on CT angiography: in vitro comparison of different stent designs and sizes using 16-, 64- and 320-row CT scanners.

    PubMed

    Lettau, Michael; Kotter, Elmar; Bendszus, Martin; Hähnel, Stefan

    2014-10-01

    CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  19. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    PubMed

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  20. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    PubMed

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P < 0.01). The radial force of the thoracic stents was greater than that of all three endovascular stents (P < 0.01). Differences in radial force depend on types of stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  1. [Percutaneously implantable aortic valve: the JenaValve concept evolution].

    PubMed

    Figulla, Hans R; Ferrari, Markus

    2006-10-01

    Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.

  2. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    PubMed

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487. © 2017 American Heart Association, Inc.

  3. Stent selection for both biliary and pancreatic strictures caused by chronic pancreatitis: multiple plastic stents or metallic stents?

    PubMed

    Gupta, Rajesh; Reddy, D Nageshwar

    2011-09-01

    Endoscopic stenting is an effective treatment option in the management of both benign biliary strictures and pancreatic ductal strictures. Plastic stents and self-expandable metal stents have been used with variable success for the management of both benign biliary strictures and pancreatic ductal strictures caused by chronic pancreatitis. Fully covered self-expandable metal stents of improved design represent a major technological advance which has added to the endoscopic armamentarium. Both multiple plastic stents and covered self-expandable metal stents have shown promising results. However, data to support the use of self-expandable metal stents over multiple plastic stents or vice versa are still lacking.

  4. Periprocedural use of tirofiban in elective percutaneous coronary intervention for long coronary lesions in stable patients with overlapping drug-eluting stents--the PETITION study: a prospective, randomized, multicenter study.

    PubMed

    Zhang, Qi; Wang, Xiao Long; Liao, Min Lei; Hu, Jian; Yang, Zhen Kun; Ding, Feng Hua; Zhang, Jian Sheng; Du, Run; Zhu, Tian Qi; Shen, Wei Feng; Zhang, Rui Yan

    2015-03-01

    Patients are at risk of developing periprocedural myonecrosis after percutaneous coronary intervention (PCI). We investigated whether the use of the platelet glycoprotein (GP) IIb/IIIa receptor inhibitor tirofiban could reduce periprocedural myocardial infarction (PMI) in patients with stable coronary artery disease undergoing elective PCI with overlapping stent implantation for long lesions. A total of 748 stable angina patients with long lesions (≥ 40 mm in length) treated with overlapping stent implantation were randomly assigned to receive tirofiban (tirofiban group; n = 373) or conventional therapy (control group; n = 375). Intravenous tirofiban was initiated before PCI and maintained for 12 hr after the procedure. The primary endpoint was PMI, defined as an elevation in CK-MB > 3 times the upper limit of normal 12 hr after the index procedure. The secondary endpoint was major adverse cardiac events (MACE), including cardiac death, target vessel revascularization, and recurrent MI (re-MI), at one-year of clinical follow-up. The safety end-points included Thrombolysis in Myocardial Infarction (TIMI) major bleeding and stent thrombosis. Despite comparable angiographic and procedural characteristics, in the intention-to-treatment analysis, the primary endpoint was significantly reduced in the tirofiban group (4.0% vs. 11.5%, P < 0.001). Multivariate analysis revealed that the adjunctive use of tirofiban was the only negative predictor of PMI (OR 0.41, 95% CI 0.28-0.81, P < 0.01). At one-year of clinical follow-up, the overall occurrence of MACE was significantly lower in the tirofiban group (13.4% vs. 22.7%, P = 0.001). The rate of TIMI major bleeding and stent thrombosis did not differ significantly between the two groups. Our results show that the adjunctive use of tirofiban reduces the occurrence of PMI and MACE at one year in stable coronary artery disease patients undergoing elective PCI for long lesions with overlapping stent implantation. © 2015 Wiley Periodicals, Inc.

  5. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography.

    PubMed

    Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S; Prothmann, Sascha

    2016-01-01

    Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.

  6. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography

    PubMed Central

    Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S.; Prothmann, Sascha

    2016-01-01

    Background Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. Methods 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Results Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Conclusion Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome. PMID:27073908

  7. Two Blades-Up Runs Using the JetStream Navitus Atherectomy Device Achieve Optimal Tissue Debulking of Nonocclusive In-Stent Restenosis: Observations From a Porcine Stent/Balloon Injury Model.

    PubMed

    Shammas, Nicolas W; Aasen, Nicole; Bailey, Lynn; Budrewicz, Jay; Farago, Trent; Jarvis, Gary

    2015-08-01

    To determine the number of runs with blades up (BU) using the JetStream Navitus to achieving optimal debulking in a porcine model of femoropopliteal artery in-stent restenosis (ISR). In this porcine model, 8 limbs were implanted with overlapping nitinol self-expanding stents. ISR was treated initially with 2 blades-down (BD) runs followed by 4 BU runs (BU1 to BU4). Quantitative vascular angiography (QVA) was performed at baseline, after 2 BD runs, and after each BU run. Plaque surface area and percent stenosis within the treated stented segment were measured. Intravascular ultrasound (IVUS) was used to measure minimum lumen area (MLA) and determine IVUS-derived plaque surface area. QVA showed that plaque surface area was significantly reduced between baseline (83.9%±14.8%) and 2 BD (67.7%±17.0%, p=0.005) and BU1 (55.4%±9.0%, p=0.005) runs, and between BU1 and BU2 runs (50.7%±9.7%, p<0.05). Percent stenosis behaved similarly with no further reduction after BU2. There were no further reductions in plaque surface area or percent stenosis with BU 3 and 4 runs (p=0.10). Similarly, IVUS (24 lesions) confirmed optimal results with BU2 runs and no additional gain in MLA or reduction in plaque surface area with BU3 and 4. IVUS confirmed no orbital cutting with JetStream Navitus. There were no stent strut discontinuities on high-resolution radiographs following atherectomy. JetStream Navitus achieved optimal tissue debulking after 2 BD and 2 BU runs with no further statistical gain in debulking after the BU2 run. Operators treating ISR with JetStream Navitus may be advised to limit their debulking to 2 BD and 2 BU runs to achieve optimal debulking. © The Author(s) 2015.

  8. Sirolimus-eluting coronary stents in octogenarians: a 1-year analysis of the worldwide e-SELECT Registry.

    PubMed

    Hong, Young Joon; Jeong, Myung Ho; Abizaid, Alexander; Banning, Adrian; Bartorelli, Antonio; Dzavik, Vladimir; Ellis, Stephen G; Gao, Runlin; Holmes, David R; Legrand, Victor; Neumann, Franz-Josef; Spaulding, Christian; Worthley, Stephen; Urban, Philip

    2011-09-01

    The aim of this study was to identify the worldwide practice of Cypher Select (Cordis Corporation, Bridgewater, New Jersey) or Cypher Select Plus sirolimus-eluting stent (SES) in patients 80 years of age (octogenarian) and to identify clinical outcomes in this patient population. The use of drug-eluting stents in elderly patients may have different features compared with younger patients. Between 2006 and 2008, 15,147 patients from 320 hospitals in 56 countries were enrolled in a registry. Initial implantation and follow-up outcome information obtained at 1-year follow-up in 675 octogenarian patients were compared with those in 14,472 nonoctogenarian patients. Octogenarians had significantly more comorbidities and had higher Charlson comorbidity index scores (1.5 ± 1.6 vs. 1.0 ± 1.3, p < 0.001). Rates of cardiac death (3.3% vs. 0.9%, p < 0.001), myocardial infarction (2.3% vs. 1.9%, p = 0.021), and definite or probable stent thrombosis (2.3% vs. 0.9%, p = 0.0002), and major bleeding (2.0% vs. 0.9%, p = 0.015) were significantly higher in octogenarians at 1 year; however, there was no significant difference in the rate of target lesion revascularization between the 2 groups (3.2% vs. 2.2%, p = 0.12). In octogenarians, a high Charlson comorbidity index was an independent predictor of death and stent thrombosis up to 360 days from the index procedure (hazard ratio: 1.3, 95% confidence interval: 1.1 to 1.5, p < 0.001, and hazard ratio: 1.5, 95% confidence interval: 1.3 to 1.8, p < 0.001, respectively). Stenting with SES may be an effective therapeutic option in elderly patients, with acceptable rates of complications and a very low rate of repeat revascularization as demonstrated by this e-SELECT (A Multi-Center Post-Market Surveillance Registry) subgroup analysis. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Effect of dissolution of magnesium alloy AZ31 on the rheological properties of Phosphate Buffer Saline.

    PubMed

    Riaz, Usman; Rakesh, Leela; Shabib, Ishraq; Haider, Waseem

    2018-06-05

    The issue of long-term incompatible interactions associated with the permanent implants can be eliminated by using various biodegradable metal implants. The recent research is focusing on the use of degradable stents to restore most of the hindrances of capillaries, and coronary arteries by supplying instant blood flow with constant mechanical and structural support. However, internal endothelialization and infection due to the corrosion of implanted stents are not easy to diagnose in the long run. In the recent past, magnesium (Mg) has been widely investigated for the cardiovascular stent applications. Here we made an attempt to understand the biodegradation process of Mg alloy stent by studying the degradation of Mg alloy AZ31 (3 wt% Aluminum, 1 wt% Zn) powder at various time-intervals in simulated blood fluid using the Rheological methods. The degradability of the Mg stent in the arteries affects the stress-strain properties of blood plasma and the subsequent flow conditions. Blood and plasma viscosities alter due to the degradation of Mg resulting from the stress-strain experienced in the blood vessels, in which the stent is inserted. Here our objective was to explore the influence of Mg degradation on the blood plasma viscosity by studying the viscoelastic properties. In this work, the effect of dissolution of Mg alloy AZ31 on the rheological properties of Phosphate Buffer Saline (PBS) at various time intervals have been investigated. The viscosity of the PBS-AZ31 solution increased with the dissolution of both slurries and percolated clear solution. The only exception was day-7 of the percolated clear solution, where viscosity was decreased showing a reduction in viscosity at initial stages of dissolution. The frequency sweep showed the tendency of the PBS-AZ31 gelation up to 100 rad/s frequency. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Drug eluting stents and modern stent technologies for in-stent restenosis.

    PubMed

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  11. Effective Endovascular Stenting of Malignant Portal Vein Obstruction in Pancreatic Cancer

    PubMed Central

    Ellis, Christian M.; Shenoy, Sadashiv; Litwin, Alan; Soehnlein, Stephanie; Gibbs, John F.

    2009-01-01

    We report herein the case of a patient successfully treated by transhepatic portal venous stent placement for malignant portal vein obstruction with associated gastric and small bowel varices and repeated gastrointestinal bleeding. CT angiography and portography showed severe portal vein obstruction from recurrent pancreatic cancer 15 months following pancreaticoduodenectomy with tumor encasement and dilated collateral veins throughout the gastric and proximal small bowel wall as the suspected cause of the GI bleeding. Successful transhepatic endovascular stent placement of the splenic vein at the portal vein confluence followed by balloon dilation was performed with immediate decompression of the gastric and small bowel varices and relief of GI hemorrhage in this patient until his death four months later. The treatment for patients with this dilemma can prove to be difficult, but as we have shown endovascular stenting of the portal system is an effective treatment option. PMID:19826629

  12. Effective endovascular stenting of malignant portal vein obstruction in pancreatic cancer.

    PubMed

    Ellis, Christian M; Shenoy, Sadashiv; Litwin, Alan; Soehnlein, Stephanie; Gibbs, John F

    2009-01-01

    We report herein the case of a patient successfully treated by transhepatic portal venous stent placement for malignant portal vein obstruction with associated gastric and small bowel varices and repeated gastrointestinal bleeding. CT angiography and portography showed severe portal vein obstruction from recurrent pancreatic cancer 15 months following pancreaticoduodenectomy with tumor encasement and dilated collateral veins throughout the gastric and proximal small bowel wall as the suspected cause of the GI bleeding. Successful transhepatic endovascular stent placement of the splenic vein at the portal vein confluence followed by balloon dilation was performed with immediate decompression of the gastric and small bowel varices and relief of GI hemorrhage in this patient until his death four months later. The treatment for patients with this dilemma can prove to be difficult, but as we have shown endovascular stenting of the portal system is an effective treatment option.

  13. [Acute stent thrombosis and reverse transient left ventricular dilatation after performing a single-photon emission computed tomography myocardial perfusion].

    PubMed

    Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J

    2015-01-01

    A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. Fatigue and In Vivo Validation of a Peritoneum-Lined Self-Expanding Nitinol Stent-Graft

    PubMed Central

    Bastijanic, Jennifer M.; Etscheidt, Jordan; Sattiraju, Mallika; Bonsignore, Craig; Kopchok, George; White, Rodney; Sarac, Timur P.

    2014-01-01

    Purpose To assess the fatigue and in vivo performance of a new stent-graft incorporating bovine peritoneum lining that is designed for application in peripheral vascular occlusive disease. Methods Bovine peritoneum-lined stent-grafts were subjected to accelerated in vitro pulsatile fatigue and axial/torsional fatigue testing designed to simulate 10 years of physiological strain on the devices. At specified times the devices were evaluated for stent fracture, suture failure, or tissue tearing. Seven dogs underwent bilateral common iliac artery (CIA) balloon angioplasty injury with unilateral placement of the peritoneum-lined stent-graft. Angiography and intravascular ultrasound were performed prior to treatment, after treatment, and prior to sacrifice at 30 days. Vessels were perfusion fixed and histologically evaluated at 5 regions: above stent, proximal stent, mid stent, distal stent, and below stent. Results No evidence of stent, suture, or tissue failure was present during or after pulsatile and axial/torsional fatigue testing. At 30±0.3 days after implantation, all vessels were patent. The average lumen area at explantation across stented vessels was 25.45 mm2. Lumen areas tended to be reduced above (23.57 mm2) and below (24.17 mm2) the stent. Lumen areas were consistent across stented regions at explantation (proximal stent 27.80 mm2, mid stent 25.88 mm2, and distal stent 25.81 mm2). The mean neointimal area in peritoneum-lined stents was 2.02±1.52 mm2, with a neointima:media ratio of 1.03±0.50. These values were significantly lower in the above and below stent areas than in the stented regions, but there was no difference in either measure within the proximal, mid, or distal stent. Conclusion The custom-designed peritoneum-lined stent-graft is promising for clinical peripheral applications due to its ability to resist relevant long-term physiological stresses and outstanding short-term patency rates in canine implantations. PMID:25290804

  15. Outcomes of the single-stent versus kissing-stents technique in asymmetric complex aortoiliac bifurcation lesions.

    PubMed

    Suh, Yongsung; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo

    2015-07-01

    This study investigated the outcomes of single-stent vs kissing-stents techniques in asymmetric complex aortoiliac bifurcation (ACAB) lesions. We retrospectively investigated 80 consecutive patients (69 males, 66.6 ± 8.7 years) treated with a single stent and 30 patients (26 males, 67.1 ± 7.7 years) treated with kissing stents for ACAB between January 2005 and December 2012 from a single-center cohort. A ACAB lesion was defined as a symptomatic unilateral common iliac artery stenosis (>50%) combined with intermediate stenosis (30%-50%) in the contralateral common iliac artery ostium. The primary end point was the primary patency of the ACAB. The baseline clinical characteristics did not differ significantly between the single-stent and the kissing-stents group. Technical success was achieved in all patients. The single-stent group required fewer stents (1.3 ± 0.5 vs 2.3 ± 0.8; P < .001) and less bilateral femoral access (55% vs 100%; P < .001). Two patients in the single-stent group (3%) required bailout kissing stents because of plaque shift to the contralateral side. The major complication rates were 8% in single-stent vs 13% in the kissing-stent group, which was similar (P = .399). At 3 years, the single-stent and kissing-stents group had similar rates of primary patency (89% vs 87%; P = .916) and target lesion revascularization-free survival (93% vs 87%; P = .462). The single-stent technique in ACAB was safe and showed midterm outcomes comparable with those of kissing stents. Considering the benefits, such as fewer stents, less bilateral femoral access, and the availability of contralateral access for future intervention, the single-stent technique may be an advantageous treatment option in ACAB. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Spectral Imaging for Intracranial Stents and Stent Lumen.

    PubMed

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P < .05) and showed the highest mean grading score (2.94 ± 0.94; P < .05) and contrast/noise ratio of in-stent lumen (160.03 ±37.79; P < .05) among all the modes. Iodine (water) images can help reduce stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  17. Percutaneous biliary covered stent insertion in patients with malignant duodenobiliary obstruction.

    PubMed

    Lee, Eunsol; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki; Shin, Ji Hoon; Kim, Jin Hyoung; Ko, Heung Kyu; Song, Ho-Young

    2015-02-01

    Although the use of polytetrafluoroethylene (PTFE)-covered biliary stents has proven to be feasible for the treatment of benign and malignant biliary disease, less is known regarding the outcomes of percutaneous placement of a covered stent in patients with malignant duodenobiliary obstruction. To investigate the technical and clinical efficacy of the percutaneous placement of a PTFE-covered biliary stent in patients with malignant duodenobiliary obstruction. From April 2007 to September 2012, the medical records of 45 consecutive patients with malignant duodenobiliary obstruction were retrospectively reviewed. All percutaneous biliary stent deployment was performed using PTFE-covered stents, whereas duodenal stent insertion was performed either fluoroscopically or endoscopically using covered or uncovered stents. Biliary stent deployment was technically successful in all patients. None of the stents migrated after deployment. Procedure-related minor complications, including self-limiting hemobilia, occurred in three (7%) patients. Successful internal drainage was achieved in 39 (87%) of the 45 patients. The median survival time after biliary stent placement was 62 days (95% confidence interval, 8-116 days), and the cumulative stent patency rates at 1, 3, 6, and 12 months were 96%, 92%, 75%, and 38%, respectively. The causes of biliary stent dysfunction included stent occlusion caused by a subsequently inserted duodenal stent (n = 7), food impaction (n = 3), and sludge incrustation (n = 1). One patient developed acute cholecystitis 131 days after biliary stent placement and underwent percutaneous transhepatic gallbladder drainage. Percutaneous insertion of a PTFE-covered stent is a safe and effective method for palliative treatment of patients with malignant duodenobiliary obstruction. If possible, subsequent biliary stent insertion is preferable in order to prevent possible biliary stent dysfunction caused by subsequent insertion of a duodenal stent. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Plastic biliary stent patency in patients with locally advanced pancreatic adenocarcinoma receiving downstaging chemotherapy.

    PubMed

    Ge, Phillip S; Hamerski, Christopher M; Watson, Rabindra R; Komanduri, Srinadh; Cinnor, Birtukan B; Bidari, Kiran; Klapman, Jason B; Lin, Cui L; Shah, Janak N; Wani, Sachin; Donahue, Timothy R; Muthusamy, V Raman

    2015-02-01

    Plastic stents in patients with biliary obstruction caused by pancreatic adenocarcinoma are typically exchanged at 3-month intervals. Plastic stents may have reduced durability in patients receiving chemotherapy. To determine the duration of plastic biliary stent patency in patients undergoing chemotherapy for pancreatic adenocarcinoma. Retrospective, multicenter cohort study. Three tertiary academic referral centers. A total of 173 patients receiving downstaging chemotherapy for locally advanced or borderline resectable pancreatic adenocarcinoma from 1996 to 2013. Placement of 10F or larger plastic biliary stents. Primary outcome was overall duration of stent patency. Secondary outcomes included the incidence of premature stent exchange (because of cholangitis or jaundice) and hospitalization rates. A total of 233 plastic stents were placed, and the overall median duration of stent patency was 53 days (interquartile range [IQR] 25-99 days). Eighty-seven stents were removed at the time of surgical resection, and 63 stents were exchanged routinely per protocol. The remaining 83 stent exchanges were performed for worsening liver function test results, jaundice, or cholangitis, representing a 35.6% rate of premature stent exchange. The median stent patency duration in the premature stent exchange group was 49 days (IQR 25-91 days) with a 44.6% hospitalization rate. The overall rate of cholangitis was 15.0% of stent exchanges, occurring a median of 56 days after stent placement (IQR 26-89 days). Retrospective study. Plastic biliary stents placed during chemotherapy/chemoradiation for pancreatic adenocarcinoma have a shorter-than-expected patency duration, and a substantial number of patients will require premature stent exchange. Consideration should be given to shortening the interval for plastic biliary stent exchange. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  19. Application of underdamped Langevin dynamics simulations for the study of diffusion from a drug-eluting stent

    NASA Astrophysics Data System (ADS)

    Regev, Shaked; Farago, Oded

    2018-10-01

    We use a one-dimensional two layer model with a semi-permeable membrane to study the diffusion of a therapeutic drug delivered from a drug-eluting stent (DES). The rate of drug transfer from the stent coating to the arterial wall is calculated by using underdamped Langevin dynamics simulations. Our results reveal that the membrane has virtually no delay effect on the rate of delivery from the DES. The work demonstrates the great potential of underdamped Langevin dynamics simulations as an easy to implement, efficient, method for solving complicated diffusion problems in systems with a spatially-dependent diffusion coefficient.

  20. Endovascular Management of Infected Femoral Artery Pseudoaneurysms in High-Risk Patients: A Case Series

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D’Oria, Mario, E-mail: mario.doria88@outlook.com; Sgorlon, Giada; Calvagna, Cristiano

    We report our experience with the urgent treatment of two high-risk patients with infected femoral artery pseudoaneurysms (IFAPs) with the placement of a self-expandable covered stent (SECS). In both cases, there was no perioperative mortality and the aneurysm exclusion was successful without early or late stent thrombosis/stent fracture nor acute or chronic limb ischemia or limb loss. There was no recurrence of local or systemic infection during the follow-up period. Endovascular therapy represents a feasible treatment option for IFAPs in those patients for whom the risk of open surgical repair would be prohibitive, especially under urgent circumstances.

Top