Sample records for stenting trial protocol

  1. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    PubMed

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  2. Results of the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) study to treat symptomatic stenoses at 2 years: a multinational, prospective, randomised trial.

    PubMed

    Eckstein, Hans-Henning; Ringleb, Peter; Allenberg, Jens-Rainer; Berger, Jürgen; Fraedrich, Gustav; Hacke, Werner; Hennerici, Michael; Stingele, Robert; Fiehler, Jens; Zeumer, Hermann; Jansen, Olav

    2008-10-01

    The SPACE trial is a multinational, prospective, randomised study to test the hypothesis that carotid artery stenting is not inferior to carotid endarterectomy for treating patients with severe symptomatic carotid artery stenosis. We did not prove non-inferiority of carotid artery stenting compared with carotid endarterectomy for the 30-day complication rate, and we now report the results at 2 years. Between March, 2001, and February, 2006, patients with symptomatic, severe (>or=70%) carotid artery stenosis were recruited to this non-inferiority trial and randomly assigned with a block randomisation design to have carotid artery angioplasty with stenting or carotid artery endarterectomy. 2-year endpoints include several clinical endpoints and the incidence of recurrent carotid stenosis of at least 70%. Clinical and vascular follow-up was done by a certified neurologist. Analyses were by intention to treat and per protocol. This trial is registered with ISRCTN, number 57874028.12. 1 214 patients were randomly assigned (613 were randomly assigned to carotid angioplasty with stenting and 601 were randomly assigned to carotid endarterectomy). In both the intention-to-treat and per-protocol analyses the Kaplan-Meier estimates of ipsilateral ischaemic strokes up to 2 years after the procedure and any periprocedural stroke or death do not differ between the carotid artery stenting and the carotid endarterectomy groups (intention to treat 9.5%vs 8.8%; hazard ratio (HR) 1.10, 95%CI 0.75 to 1.61; log-rank p=0.62; per protocol 9.4%vs 7.8%; HR 1.23, 95%CI 0.82 to 1.83; log-rank p=0.31). In both the intention-to-treat and per-protocol populations, recurrent stenosis of 70% or more is significantly more frequent in the carotid artery stenting group compared with the carotid endarterectomy group, with a life-table estimate of 10.7% versus 4.6% (p=0.0009) and 11.1% versus 4.6% (p=0.0007), respectively. Only two incidences of recurrent stenoses after carotid artery stenting led to neurological symptoms. After 2 years' follow-up, the rate of recurrent ipsilateral ischaemic strokes reported in the SPACE trial is similar for both treatment groups. The incidence of recurrent carotid stenosis at 2 years, as defined by ultrasound, is significantly higher after carotid artery stenting. However, it cannot be excluded that the degree of in-stent stenosis is slightly overestimated by conventional ultrasound criteria.

  3. The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial: study protocol for a randomized controlled trial

    PubMed Central

    2012-01-01

    Background Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734. PMID:22463698

  4. Palliative radiotherapy in addition to self-expanding metal stent for improving dysphagia and survival in advanced oesophageal cancer (ROCS: Radiotherapy after Oesophageal Cancer Stenting): study protocol for a randomized controlled trial.

    PubMed

    Adamson, Douglas; Blazeby, Jane; Nelson, Annmarie; Hurt, Chris; Nixon, Lisette; Fitzgibbon, Jim; Crosby, Tom; Staffurth, John; Evans, Mim; Kelly, Noreen Hopewell; Cohen, David; Griffiths, Gareth; Byrne, Anthony

    2014-10-22

    The single most distressing symptom for patients with advanced esophageal cancer is dysphagia. Amongst the more effective treatments for relief of dysphagia is insertion of a self-expanding metal stent (SEMS). It is possible that the addition of a palliative dose of external beam radiotherapy may prolong the relief of dysphagia and provide additional survival benefit. The ROCS trial will assess the effect of adding palliative radiotherapy after esophageal stent insertion. The study is a randomized multicenter phase III trial, with an internal pilot phase, comparing stent alone versus stent plus palliative radiotherapy in patients with incurable esophageal cancer. Eligible participants are those with advanced esophageal cancer who are in need of stent insertion for primary management of dysphagia. Radiotherapy will be administered as 20 Gray (Gy) in five fractions over one week or 30 Gy in 10 fractions over two weeks, within four weeks of stent insertion. The internal pilot will assess rates and methods of recruitment; pre-agreed criteria will determine progression to the main trial. In total, 496 patients will be randomized in a 1:1 ratio with follow up until death. The primary outcome is time to progression of patient-reported dysphagia. Secondary outcomes include survival, toxicity, health resource utilization, and quality of life. An embedded qualitative study will explore the feasibility of patient recruitment by examining patients' motivations for involvement and their experiences of consent and recruitment, including reasons for not consenting. It will also explore patients' experiences of each trial arm. The ROCS study will be a challenging trial studying palliation in patients with a poor prognosis. The internal pilot design will optimize methods for recruitment and data collection to ensure that the main trial is completed on time. As a pragmatic trial, study strengths include collection of all follow-up data in the usual place of care, and a focus on patient-reported, rather than disease-orientated, outcomes. Exploration of patient experience and health economic analyses will be integral to the assessment of benefit for patients and the NHS. The trial was registered with Current Controlled Trials (registration number: ISRCTN12376468) on 10 July 2012.

  5. Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis - coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial.

    PubMed

    Kim, Chi-Hoon; Han, Jung-Kyu; Yang, Han-Mo; Park, Kyung Woo; Lee, Hae-Young; Kang, Hyun-Jae; Koo, Bon-Kwon; Lee, Namho; Cha, Tae-Joon; Yang, Tae-Hyun; Jeong, Myung-Ho; Yoon, Myeong-Ho; Lee, Seung Uk; Lee, Seung Jin; Kim, Jin Won; Cho, Jin-Man; Han, Kyoo-Rok; Pyun, Wook Bum; Kim, Hyo-Soo

    2017-10-11

    We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultrathin stents with the newest polymer technologies. The HOST-IDEA trial is a randomised, open-label, multicentre, non-inferiority trial and the first study to directly compare two of these ultrathin sirolimus-eluting stents: Orsiro stent with biodegradable polymer, and polymer-free Coroflex ISAR (CX-ISAR) stent. This study has a scheme of 2×2 factorial design according to the stent type and DAPT duration (3 vs 12 months). A total of 2152 patients will be randomised and stratified to demonstrate the non-inferiority of CX-ISAR to Orsiro, or of the abbreviated DAPT duration to the conventional 12 months (both in 1:1 ratio). For the comparison of stent type, the primary endpoint is target lesion failure (TLF), which is a composite of cardiac death, target vessel-related myocardial infarction and clinically driven target lesion revascularisation. For the comparison of DAPT duration, the net adverse clinical event is the coprimary endpoint, which is defined as a composite of TLF, definite/probable stent thrombosis and major bleeding. All the institutions involved in this study are required to have ethical approval prior to patient enrolment. This multicentre study will recruit patients through competitive registration, but institutions that have not yet obtained ethical approvals have made it impossible to enrol patients in a centralised web database. The final results will be presented at relevant international conferences and will be materialised in the form of papers. NCT02601157; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Carotid artery stenting versus no stenting assisting thrombectomy for acute ischaemic stroke: protocol for a systematic review of randomised clinical trials with meta-analyses and trial sequential analyses.

    PubMed

    Steglich-Arnholm, Henrik; Holtmannspötter, Markus; Gluud, Christian; Krieger, Derk Wolfgang

    2016-12-01

    In patients with intracranial large vessel arterial occlusion, ipsilateral extracranial carotid artery occlusions or near-occlusions pose a significant hurdle in endovascular management of acute ischaemic stroke. Stenting of the carotid lesion may be beneficial in this situation to provide a stable access for introducing catheters through the carotid lesion into the intracranial vasculature and the target occlusion. Furthermore, carotid stenting may ensure ample blood flow for wash-out of clot material and reperfusion of the ischaemic penumbral tissue. However, antiplatelet therapy administered to prevent stent thrombosis and sudden increase in blood flow after reopening of the carotid lesion may increase the risk for intracranial haemorrhagic complications. This review aims to assess the benefits and harms of carotid stenting vs. no stenting assisting thrombectomy for acute ischaemic stroke. International and regional electronic databases will be searched to identify eligible randomised clinical trials. To identify further published, unpublished, or on-going and planned trials searches of Google Scholar, Worldwide Food and Drug Administrations, Worldwide Medicines Agencies, company homepages, reference lists, conference proceedings, and the Science Citation Index cited reference search index will be conducted. Manufacturers of relevant interventional equipment, authors, colleagues, and researchers active in the field will be contacted. No language restrictions will be applied to these searches. Randomised clinical trials will be included for assessing benefits and harms and quasi-randomised studies, and observational studies will be included for assessing harms of the intervention. Meta-analyses will be performed according to the recommendations of the Cochrane Handbook for Systematic Reviews of Interventions, and Trial Sequential Analyses will be conducted to control the risk of random errors and prevent premature statements of superiority of the experimental or control intervention or premature statement of futility. The quality of the evidence will be evaluated with the Grading of Recommendations Assessment, Development, and Evaluation. This systematic review of carotid stenting in endovascular management of acute ischaemic stroke in patients with concomitant extracranial carotid lesions and intracranial embolism will assess benefits and harms of this intervention and assesses whether carotid stenting should be encouraged or avoided in acute ischaemic stroke and identify targets for further research. PROSPERO CRD42016033346.

  7. Metal or plastic stents for preoperative biliary drainage in resectable pancreatic cancer.

    PubMed

    Tol, J A M G; van Hooft, J E; Timmer, R; Kubben, F J G M; van der Harst, E; de Hingh, I H J T; Vleggaar, F P; Molenaar, I Q; Keulemans, Y C A; Boerma, D; Bruno, M J; Schoon, E J; van der Gaag, N A; Besselink, M G H; Fockens, P; van Gulik, T M; Rauws, E A J; Busch, O R C; Gouma, D J

    2016-12-01

    In pancreatic cancer, preoperative biliary drainage (PBD) increases complications compared with surgery without PBD, demonstrated by a recent randomised controlled trial (RCT). This outcome might be related to the plastic endoprosthesis used. Metal stents may reduce the PBD-related complications risk. A prospective multicentre cohort study was performed including patients with obstructive jaundice due to pancreatic cancer, scheduled to undergo PBD before surgery. This cohort was added to the earlier RCT (ISRCTN31939699). The RCT protocol was adhered to, except PBD was performed with a fully covered self-expandable metal stent (FCSEMS). This FCSEMS cohort was compared with the RCT's plastic stent cohort. PBD-related complications were the primary outcome. Three-group comparison of overall complications including early surgery patients was performed. 53 patients underwent PBD with FCSEMS compared with 102 patients treated with plastic stents. Patients' characteristics did not differ. PBD-related complication rates were 24% in the FCSEMS group vs 46% in the plastic stent group (relative risk of plastic stent use 1.9, 95% CI 1.1 to 3.2, p=0.011). Stent-related complications (occlusion and exchange) were 6% vs 31%. Surgical complications did not differ, 40% vs 47%. Overall complication rates for the FCSEMS, plastic stent and early surgery groups were 51% vs 74% vs 39%. For PBD in pancreatic cancer, FCSEMS yield a better outcome compared with plastic stents. Although early surgery without PBD remains the treatment of choice, FCSEMS should be preferred over plastic stents whenever PBD is indicated. Dutch Trial Registry (NTR3142). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial.

    PubMed

    Stone, Gregg W; Teirstein, Paul S; Meredith, Ian T; Farah, Bruno; Dubois, Christophe L; Feldman, Robert L; Dens, Joseph; Hagiwara, Nobuhisa; Allocco, Dominic J; Dawkins, Keith D

    2011-04-19

    We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI). Randomized trials have demonstrated an excellent safety and efficacy profile for the CoCr-EES. The PtCr-EES uses the identical antiproliferative agent and polymer but with a novel platinum chromium scaffold designed for enhanced deliverability, vessel conformability, side-branch access, radiopacity, radial strength, and fracture resistance. A total of 1,530 patients undergoing PCI of 1 or 2 de novo native lesions were randomized at 132 worldwide sites to CoCr-EES (n = 762) or PtCr-EES (n = 768). The primary endpoint was the 12-month rate of target lesion failure (TLF), the composite of target vessel-related cardiac death, target vessel-related myocardial infarction (MI), or ischemia-driven target lesion revascularization (TLR) in the per-protocol population (patients who received ≥1 assigned study stent), powered for noninferiority. The 12-month rate of TLF in the per-protocol population occurred in 2.9% versus 3.4% of patients assigned to CoCr-EES versus PtCr-EES, respectively (difference: 0.5%, 95% confidence interval: -1.3% to 2.3%, p(noninferiority) = 0.001, p(superiority) = 0.60). By intention-to-treat, there were no significant differences between CoCr-EES and PtCr-EES in the 12-month rates of TLF (3.2% vs. 3.5%, p = 0.72), cardiac death or MI (2.5% vs. 2.0%, p = 0.56), TLR (1.9% vs. 1.9%, p = 0.96), or Academic Research Consortium definite or probable stent thrombosis (0.4% vs. 0.4%, p = 1.00). In this large-scale, prospective, single-blind randomized trial, a novel PtCr-EES was noninferior to the predicate CoCr-EES for TLF, with nonsignificant differences in measures of safety and efficacy through 12-month follow-up after PCI. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. The INNOVATION Trial: four-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System for endovascular repair.

    PubMed

    Pratesi, Giovanni; Pratesi, Carlo; Chiesa, Roberto; Coppi, Gioacchino; Scheinert, Dierk; Brunkwall, Jan S; van der Meulen, Stefaan; Torsello, Giovanni

    2017-10-01

    This paper reports the 4-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System (Cordis Corp., Milpitas, CA, USA), an ultra-low-profile device for the treatment of abdominal aortic aneurysms. The INNOVATION Trial is the prospective, first-in-human, multicenter trial to evaluate the safety and effectiveness of the INCRAFT® System. Patients underwent annual clinical and computed tomography angiography examination as part of the study protocol. The INCRAFT® AAA Stent-Graft System is a customizable tri-modular design, with an ultra-low profile (14-Fr) delivery system. Patient were treated under approved protocol, the prescribed clinical and imaging follow-up at annually through 5 years. Results analyzed and adjudicated by a clinical events committee, independent core laboratory, and a data safety and monitoring board. This manuscript reports results through 4 years of follow-up. A total of 60 patients were enrolled in the trial, all of whom were successfully treated. Follow-up rates at 1 and 4 years were 93% (56/60) and 85% (51/60), respectively. All-cause mortality at 4 years was 17.6% and no death was AAA-, device-, or procedure-related. The secondary reintervention rate at 1 year was 4.6%, primarily the result of stent thrombosis. In total, 10 patients required 13 post-procedure interventions within 4-years of follow-up (2 to repair a type I endoleak, 4 to repair a type II endoleak, 1 for stent thrombosis, 1 for renal stenosis, 1 for aneurysm enlargement, 2 for limb migration and 2 for prosthesis stenosis or occlusion). There were 4 cases (10%) of aneurysm enlargement reported at the 4 year follow-up. At 4 years, 38 out of 39 patients were free from type I and III endoleaks. There were no proximal type I or type III endoleaks at 4-year follow-up. Core laboratory evaluation of the postoperative imaging studies indicated absence of endograft migration while a single fracture was demonstrated without any clinical sequelae. The INCRAFT® AAA Stent-Graft System provides a minimally invasive and durable solution for patients undergoing EVAR that has been associated with a low frequency of device-related events through 4 years of follow-up.

  10. Protection or nonprotection in carotid stent angioplasty: the influence of interventional techniques on outcome data from the SPACE Trial.

    PubMed

    Jansen, Olav; Fiehler, Jens; Hartmann, Marius; Brückmann, Hartmut

    2009-03-01

    The use of protection devices (PDs) and stents with different cell designs in carotid artery stenting (CAS) is a subject of controversy, and no data on their benefit are available from independently controlled multi-center studies. We analyzed data from the prospective randomized SPACE trial, which included 563 patients randomized to CAS and treated per protocol. A total of 145 patients were treated with a PD and 418 without. Of the patients, 436 were treated with an open cell stent and 127 with a closed cell stent. Use of PDs and choice of device was chosen at the individual discretion of the interventionalist. The outcome event (OE) of the analysis (ipsilateral stroke or ipsilateral stroke death within 30 days) was reached in 26/418 patients (6.2%, 95% CI: 4.1 to 9.0%) in the nonprotection [corrected] group and in 12/145 (8.3%, 95% CI: 4.3 to 14.0%) patients in the protection [corrected] group (P=0.40). The OE rate was significantly lower in patients treated with a closed cell stent (5.6% [95% CI: 3.7 to 8.2%]) than in those treated with an open cell stent.(11.0%, 95% CI: 6.2 to 17.8%; P=0.029). Predilatation showed a tendency to but no significant reduction of OE rate. Overall, 49% of all OEs occurred directly periinterventionally, 10% during the navigation procedure and 41% postinterventionally, including 10% of hyperperfusion syndromes. Time point of the event was not influenced by the use of a PD. This secondary analysis of data from the SPACE trial does not support the need for a PD in CAS. Stent design seems to have an impact on the OE rate. Our analysis demonstrates that the choice of the interventional material may have an impact on the periprocedural complication rate in CAS and that the development of more specific stent systems for the treatment of carotid stenosis may reduce the complication rate significantly.

  11. Optimization of stent implantation using a high pressure inflation protocol.

    PubMed

    Vallurupalli, Srikanth; Bahia, Amit; Ruiz-Rodriguez, Ernesto; Ahmed, Zubair; Hakeem, Abdul; Uretsky, Barry F

    2016-01-01

    High-pressure inflation is the universal standard for stent deployment but a specific protocol for its use is lacking. We developed a standardized "pressure optimization protocol" (POP) using time to inflation pressure stability as an endpoint for determining the required duration of stent inflation. The primary study purpose was to determine the stent inflation time (IT) in a large patient cohort using the standardized inflation protocol, to correlate various patient and lesion characteristics with IT, and ascertain in an in vitro study the time for pressure accommodation within an inflation system. Six hundred fifteen stent implants in 435 patients were studied. Multivariate analysis was performed to determine predictors of longer ITs. In an in vitro study, various stents and balloons were inflated in air to determine the pressure accommodation time of the inflation system. The mean stent IT was 104 ± 41 sec (range 30-380 sec). Stent length was the only predictor of prolonged stent inflation. The "accommodation time" in vitro of the stent inflation system itself was 33 ± 24 sec. The protocol was safe requiring premature inflation termination in <3% of stent implants. No serious adverse events occurred. Achieving stable inflation pressure requires on average over 100 sec and may require several minutes in individual cases. Stent length increases IT. These results suggest that the widespread practice of rapid inflation/deflation may not be sufficient to fully expand the stent and that the use of a pressure stability protocol will allow for safe, predictable, and more complete stent deployment. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Angioplasty and stenting for patients with symptomatic intracranial atherosclerosis: study protocol of a randomised controlled trial

    PubMed Central

    Cui, Xiao-Ping; Lin, Min; Mu, Jun-Shan; Ye, Jian-Xin; He, Wen-Qing; Fu, Mao-Lin; Li, Hua; Fang, Jia-Yang; Shen, Feng-Feng; Lin, Hang

    2016-01-01

    Introduction Whether adding percutaneous transluminal angioplasty and stenting (PTAS) to background medical treatment is effective for decreasing the incidence of stroke or death in patients with symptomatic intracranial atherosclerosis (ICAS) is still controversial. We perform a randomised controlled trial to examine the effectiveness and safety of an improved PTAS procedure for patients with ICAS. Methods and analysis A randomised controlled trial will be conducted in three hospitals in China. Eligible patients with ICAS will be randomly assigned to receive medication treatment (MT) plus PTAS or MT alone. The MT will be initiated immediately after randomisation, while the PTAS will be performed when patients report relief of alarm symptoms defined as sudden weakness or numbness. All patients will be followed up at 30 days, 3 and 12 months after randomisation. The primary end point will be the incidence of stroke or death at 30 days after randomisation. Secondary outcomes will be the incidence of ischaemic stroke in the territory of stenosis arteries, the incidence of in-stent restenosis, the Chinese version of the modified Rankin Scale and the Chinese version of the Stroke-Specific Quality of Life (CSQoL). Ethics and dissemination The study protocol is approved by institutional review boards in participating hospitals (reference number FZ20160003, 180PLA20160101 and 476PLA2016007). The results of this study will be disseminated to patients, physicians and policymakers through publication in a peer-reviewed journal or presentations in conferences. It is anticipated that the results of this study will improve the quality of the current PTAS procedure and guide clinical decision-making for patients with ICAS. Trial registration number NCT02689037 PMID:27852711

  13. The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis): Angiographic Results and 1-Year Clinical Outcomes.

    PubMed

    Verheye, Stefan; Vrolix, Mathias; Kumsars, Indulis; Erglis, Andrejs; Sondore, Dace; Agostoni, Pierfrancesco; Cornelis, Kristoff; Janssens, Luc; Maeng, Michael; Slagboom, Ton; Amoroso, Giovanni; Jensen, Lisette Okkels; Granada, Juan F; Stella, Pieter

    2017-10-23

    The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR). Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR. In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes that warrant further evaluation in dedicated randomized studies. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Effects of clopidogrel, prasugrel and ticagrelor on endothelial function, inflammatory and oxidative stress parameters and platelet function in patients undergoing coronary artery stenting for an acute coronary syndrome. A randomised, prospective, controlled study

    PubMed Central

    Schnorbus, Boris; Daiber, Andreas; Jurk, Kerstin; Warnke, Silke; König, Jochem; Krahn, Ulrike; Lackner, Karl; Munzel, Thomas; Gori, Tommaso

    2014-01-01

    Introduction Particularly in the setting of acute coronary syndromes, the interplay between vascular and platelet function has been postulated to have direct clinical implications. The present trial is designed to test the effect of clopidogrel, prasugrel and ticagrelor on multiple parameters of vascular function, platelet aggregation, oxidative and inflammatory stress before and up to 4 weeks after coronary artery stenting. Methods and analysis The study is designed as a three-arm, parallel design, randomised, investigator-blinded study. Patients with unstable angina or non-ST elevation myocardial infarction undergoing coronary intervention with a drug-eluting stent will be randomised to receive 600 mg clopidogrel, 60 mg prasugrel or 180 mg ticagrelor followed by oral therapy with the same drug. The primary endpoint of the trial is the impact of antiplatelet treatments on endothelial function as assessed by flow-mediated dilation at 1 day, 1 week and 1 month in patients who have undergone stenting. Secondary endpoints include the impact of study medications on parameters of macrovascular and microvascular function, platelet reactivity, oxidative and inflammatory stress. The study recruitment is currently ongoing and, after an interim analysis which was performed at 50% of the initially planned population, it is planned to continue until July 2015. Ethics and dissemination The protocol was approved by the local ethics committee. The trial will provide important pathophysiological insight on the relationship between platelet aggregation and endothelial function, two parameters that have been shown to influence patients’ prognosis. Trial registration number ClinicalTrials.gov Identifier: NCT01700322; EudraCT-Nr.: 2011-005305-73. Current V.1.3, from 24 February 2014. PMID:24801283

  15. Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial.

    PubMed

    Lee, Michael; Généreux, Philippe; Shlofmitz, Richard; Phillipson, Daniel; Anose, Bynthia M; Martinsen, Brad J; Himmelstein, Stevan I; Chambers, Jeff W

    2017-06-01

    The presence of heavy coronary artery calcification increases the complexity of percutaneous coronary intervention (PCI) and increases the incidence of major adverse cardiac events (MACE): death, myocardial infarction (MI), target vessel revascularization (TVR), and stent thrombosis. The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial reported low rates of procedural, 30-day, 1-year, and 2-year ischemic complications after treatment of de novo, severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc.). ORBIT II was a single-arm trial that enrolled 443 patients at 49U.S. sites; in this study, de novo, severely calcified coronary lesions were treated with OAS prior to stenting. The primary safety endpoint was 30-day MACE: the composite of cardiac death, MI, and TVR (inclusive of target lesion revascularization (TLR)). The primary efficacy endpoint was procedural success: stent delivery with a residual stenosis of <50% without the occurrence of in-hospital MACE.The present analysis reports the final, 3-year follow-up results from ORBIT II. The majority of subjects (88.2%) underwent PCI with drug-eluting stents after orbital atherectomy. There were 360 (81.3%) subjects who completed the protocol-mandated 3-year visit.The overall cumulative rate of 3-year MACE was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%). The 3-year target lesion revascularization rate was 7.8%. In the final 3-year analysis of the ORBIT II trial, orbital atherectomy of severely calcified coronary lesions followed by stenting resulted in a low rate of adverse ischemic events compared with historical controls.Orbital atherectomy represents a safe and effective revascularization strategy for patients with severely calcified coronary lesions. The ORBIT II trial enrolled 443 subjects to study orbital atherectomy followed by stenting for de novo severely calcified coronary lesions. The overall cumulative 3-year MACE rate was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%); the 3-year target lesion revascularization rate was 7.8%. Orbital atherectomy of heavily calcified coronary lesions followed by stenting results in a low rate of adverse ischemic events compared with historical controls; it represents a reasonable revascularization strategy for patients with severely calcified coronary lesions. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Treatment of symptomatic carotid stenosis: carotid stent placement versus endarterectomy.

    PubMed

    Alqadri, Syeda L; Qureshi, Adnan I

    2013-08-01

    The mainstay of treatment options for symptomatic carotid stenosis is focused around medical management, carotid endarterectomy, and carotid angioplasty and stent placement. The International Carotid Stenting Study (ICSS), also called Carotid and Vertebral Artery Transluminal Angioplasty Study 2 (CAVATAS 2), the Stent-Supported Percutaneous Angioplasty of the Carotid Artery Versus Endarterectomy (SPACE) trial, the Endarterectomy Versus Angioplasty in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S) trial, the Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy (SAPPHIRE) trial, and the Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST) were five major trials which compared carotid endarterectomy and carotid angioplasty and stent placement. We review the results of the trials and incorporation of the results into clinical decision making.

  17. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial.

    PubMed

    Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu

    2016-06-27

    The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p < 0.001). At 1 year, there was no difference in the DoCE between both devices (BVS 5.2% vs. EES 3.1%; p = 0.29). Post-procedural devices asymmetry and eccentricity were related to higher event rates while there was no relevance to the expansion status. Subsequent multivariate analysis identified that post-procedural AI >0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial

    PubMed Central

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-01-01

    Introduction The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. Methods and analysis We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. Ethics and dissemination This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016–0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. Trial registration number The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. PMID:28801436

  19. Short-term outcome after stenting versus endarterectomy for symptomatic carotid stenosis: a preplanned meta-analysis of individual patient data.

    PubMed

    Bonati, Leo H; Dobson, Joanna; Algra, Ale; Branchereau, Alain; Chatellier, Gilles; Fraedrich, Gustav; Mali, Willem P; Zeumer, Hermann; Brown, Martin M; Mas, Jean-Louis; Ringleb, Peter A

    2010-09-25

    Results from randomised controlled trials have shown a higher short-term risk of stroke associated with carotid stenting than with carotid endarterectomy for the treatment of symptomatic carotid stenosis. However, these trials were underpowered for investigation of whether carotid artery stenting might be a safe alternative to endarterectomy in specific patient subgroups. We therefore did a preplanned meta-analysis of individual patient data from three randomised controlled trials. Data from all 3433 patients with symptomatic carotid stenosis who were randomly assigned and analysed in the Endarterectomy versus Angioplasty in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S) trial, the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) trial, and the International Carotid Stenting Study (ICSS) were pooled and analysed with fixed-effect binomial regression models adjusted for source trial. The primary outcome event was any stroke or death. The intention-to-treat (ITT) analysis included all patients and outcome events occurring between randomisation and 120 days thereafter. The per-protocol (PP) analysis was restricted to patients receiving the allocated treatment and events occurring within 30 days after treatment. In the first 120 days after randomisation (ITT analysis), any stroke or death occurred significantly more often in the carotid stenting group (153 [8·9%] of 1725) than in the carotid endarterectomy group (99 [5·8%] of 1708, risk ratio [RR] 1·53, [95% CI 1·20-1·95], p=0·0006; absolute risk difference 3·2 [1·4-4·9]). Of all subgroup variables assessed, only age significantly modified the treatment effect: in patients younger than 70 years (median age), the estimated 120-day risk of stroke or death was 50 (5·8%) of 869 patients in the carotid stenting group and 48 (5·7%) of 843 in the carotid endarterectomy group (RR 1·00 [0·68-1·47]); in patients 70 years or older, the estimated risk with carotid stenting was twice that with carotid endarterectomy (103 [12·0%] of 856 vs 51 [5·9%] of 865, 2·04 [1·48-2·82], interaction p=0·0053, p=0·0014 for trend). In the PP analysis, risk estimates of stroke or death within 30 days of treatment among patients younger than 70 years were 43 (5·1%) of 851 patients in the stenting group and 37 (4·5%) of 821 in the endarterectomy group (1·11 [0·73-1·71]); in patients 70 years or older, the estimates were 87 (10·5%) of 828 patients and 36 (4·4%) of 824, respectively (2·41 [1·65-3·51]; categorical interaction p=0·0078, trend interaction p=0·0013]. Stenting for symptomatic carotid stenosis should be avoided in older patients (age ≥70 years), but might be as safe as endarterectomy in younger patients. The Stroke Association. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Rationale and design of the East-West late lumen loss study: Comparison of late lumen loss between Eastern and Western drug-eluting stent study cohorts.

    PubMed

    Harrison, Robert W; Radhakrishnan, Vaishnavi; Lam, Peter S; Allocco, Dominic J; Brar, Sandeep; Fahy, Martin; Fisher, Rebecca; Ikeno, Fumiaki; Généreux, Philippe; Kimura, Takeshi; Liu, Minglei; Lye, Weng Kit; Mintz, Gary S; Nagai, Hirofumi; Suzuki, Yuka; White, Roseann; Allen, John C; Krucoff, Mitchell W

    2016-12-01

    The contemporary evaluation of novel drug-eluting stents (DES) includes mechanistic observations that characterize postdeployment stent behavior. Quantification of late lumen loss due to neointimal hyperplasia 8-13 months after stent implantation, via quantitative coronary angiography (QCA), constitutes such an observation and is required by most regulatory authorities. Late lumen loss, as determined by QCA, has been validated as a surrogate for clinical endpoints such as target vessel revascularization. The mechanistic response to DES has not been directly compared across predominantly Asian or Western populations, whereas understanding their comparability across geographic populations could enhance global DES evaluation. The East-West late lumen loss study is designed to demonstrate whether the residual differences in late lumen loss, as assessed by QCA, is different between Eastern and Western DES recipients from studies with protocol angiography at 8-13 months of follow-up. Data from independent core laboratories that have characterized angiographic late lumen loss in DES clinical trials with protocol follow-up angiography will be compiled and dichotomized into Eastern and Western populations. A prospectively developed propensity score model incorporating clinical and anatomic variables affecting late lumen loss will be used to adjust comparisons of QCA measurements. Documentation of whether there are clinically meaningful differences in mechanistic response to DES implantation across genetically unique geographies could facilitate both the quality and efficiency of global device evaluation requiring invasive follow-up for novel stent designs. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Carotid artery stenting in the SPACE and EVA-3S trials: analysis and update.

    PubMed

    Mansour, M Ashraf

    2008-03-01

    Carotid artery stenting is an alternative to carotid endarterectomy. Although the stroke and mortality rates after stenting are low, it is yet to be proved that stenting is superior or equal to endarterectomy in low-risk symptomatic and asymptomatic patients. A summary of the results of 2 recent trials comparing carotid stenting with carotid endarterectomy, SPACE, and EVA-3S, is presented herein. Both trials failed to prove noninferiority of carotid stenting compared with carotid endarterectomy.

  2. Interventional radiology and the use of metal stents in nonvascular clinical practice: a systematic overview.

    PubMed

    Pron, G; Common, A; Simons, M; Ho, C S

    1999-05-01

    The intent of this systematic overview was to describe the clinical role of metal stents in nonvascular health care interventions and the level of evidence supporting their use. Structured searches of Medline were conducted and limited to original peer-reviewed articles published in English. Clinical practice involving metal stents was reported in more than 109 clinical series involving 4,753 patients. Stents were placed mainly for palliation of malignant biliary, esophageal, and airway obstruction in patients who were untreatable or had surgically unresectable lesions. Assessment of these interventions has so far centered on safety and technical success. Efficacy, quality of life, and costing factors were not routinely reported. Randomized trial evidence was available but limited; six randomized trials involving metal stents have been reported. Three trials involved biliary malignant obstruction, and all three reported metal stent (132 patients) palliation to be superior to plastic stent palliation (136 patients) based on longer patency and lower reintervention costs. Safety and complication differences between stents, however, were inconsistent across trials. In three trials involving esophageal malignant obstruction, metal stent (82 patients) palliation was reported to be superior to plastic stent (41 patients), based on lower complication and reintervention rates, and superior to laser therapy (18 patients), based on better dysphagia relief. Use of metal stents has been reported for obstructed ducts and passageways of most body systems. There is, however, limited controlled trial evidence confirming the advantages of their use over plastic stents or other forms of treatment.

  3. Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

    PubMed Central

    Kirchner, R Michael; Abbott, J Dawn

    2009-01-01

    Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher®) and paclitaxel-eluting (Taxus®) stents and later approved second-generation everolimus-eluting (Xience V®) and zotarolimus-eluting (Endeavor®) stents. The Xience V stent was approved on the basis of clinical efficacy and safety data from 3 studies in the SPIRIT clinical trial program. Within this trial series, the Xience V was superior to its bare metal stent counterpart, the Vision® stent, and noninferior to the paclitaxel-eluting stent for target vessel failure at 9 months. This review provides a comprehensive assessment of the data derived from both the pre- and post-approval randomized controlled trials and registry studies of Xience V that comprise the SPIRIT clinical trial program including recently published mid-term outcomes. The implications of the results in terms of interventional practice will be discussed. PMID:20057901

  4. Impact of Clinical Trial Results on the Temporal Trends of Carotid Endarterectomy and Stenting From 2002 to 2014

    PubMed Central

    Hussain, Mohamad A.; Mamdani, Muhammad; Tu, Jack V.; Saposnik, Gustavo; Khoushhal, Zeyad; Aljabri, Badr; Verma, Subdoh

    2016-01-01

    Background and Purpose— Randomized trials provide conflicting data for the efficacy of carotid-artery stenting compared with endarterectomy. The purpose of this study was to examine the impact of conflicting clinical trial publications on the utilization rates of carotid revascularization procedures. Methods— We conducted a population-level time-series analysis of all individuals who underwent carotid endarterectomy and stenting in Ontario, Canada (2002–2014). The primary analysis examined temporal changes in the rates of carotid revascularization procedures after publications of major randomized trials. Secondary analyses examined changes in overall and age, sex, carotid-artery symptom, and operator specialty–specific procedure rates. Results— A total of 16 772 patients were studied (14 394 endarterectomy [86%]; 2378 stenting [14%]). The overall rate of carotid revascularization decreased from 6.0 procedures per 100 000 individuals ≥40 years old in April 2002 to 4.3 procedures in the first quarter of 2014 (29% decrease; P<0.001). The rate of endarterectomy decreased by 36% (P<0.001), whereas the rate of carotid-artery stenting increased by 72% (P=0.006). We observed a marked increase (P=0.01) in stenting after publication of the SAPPHIRE trial (Stenting and Angioplasty With Protection in Patients at High Risk for Endarterectomy) in 2004, whereas stenting remained relatively unchanged after subsequent randomized trials published in 2006 (P=0.11) and 2010 (P=0.34). In contrast, endarterectomy decreased after trials published in 2006 (P=0.04) and 2010 (P=0.005). Conclusions— Although the overall rates of carotid revascularization and endarterectomy have fallen since 2002, the rate of carotid-artery stenting has risen since the publication of stenting-favorable SAPPHIRE trial. Subsequent conflicting randomized trials were associated with a decreasing rate of carotid endarterectomy. PMID:27834754

  5. Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome trial.

    PubMed

    Kaiser, Christoph; Galatius, Soeren; Jeger, Raban; Gilgen, Nicole; Skov Jensen, Jan; Naber, Christoph; Alber, Hannes; Wanitschek, Maria; Eberli, Franz; Kurz, David J; Pedrazzini, Giovanni; Moccetti, Tiziano; Rickli, Hans; Weilenmann, Daniel; Vuillomenet, André; Steiner, Martin; Von Felten, Stefanie; Vogt, Deborah R; Wadt Hansen, Kim; Rickenbacher, Peter; Conen, David; Müller, Christian; Buser, Peter; Hoffmann, Andreas; Pfisterer, Matthias

    2015-01-06

    Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. © 2014 American Heart Association, Inc.

  6. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats.

    PubMed

    de Jonge, Paul K J D; Sloff, Marije; Janke, Heinz P; Kortmann, Barbara B M; de Gier, Robert P E; Geutjes, Paul J; Oosterwijk, Egbert; Feitz, Wout F J

    2017-10-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats. Similarly to a previous study in pigs, the ureteral J-stent was blindly inserted until some resistance was met. During evaluation of the goats after three months, perforation of the renal cortex by the stent was observed in four out of seven animals. These results indicated that blind stent placement was not possible in goats. In four new goats, clinical protocols were followed using X-ray and iodinated contrast fluids to visualize the kidney and stent during stent placement. With this adaptation the stents were successfully placed in the kidneys of these four new goats with minimal additional effort. It is likely that other groups in other fields ran into similar problems that could have been avoided by following clinical protocols. Therefore, we would like to stress the importance of following clinical protocols when using medical devices in animals to prevent unnecessary suffering and to reduce the number of animals needed.

  7. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis

    PubMed Central

    Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-01-01

    Objectives To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. PMID:25378023

  8. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    PubMed

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  9. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    PubMed

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  10. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    PubMed Central

    Bonati, Leo H; Dobson, Joanna; Featherstone, Roland L; Ederle, Jörg; van der Worp, H Bart; de Borst, Gert J; Mali, Willem P Th M; Beard, Jonathan D; Cleveland, Trevor; Engelter, Stefan T; Lyrer, Philippe A; Ford, Gary A; Dorman, Paul J; Brown, Martin M

    2015-01-01

    Summary Background Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. Methods Patients with symptomatic carotid stenosis were randomly assigned 1:1 to open treatment with stenting or endarterectomy at 50 centres worldwide. Randomisation was computer generated centrally and allocated by telephone call or fax. Major outcomes were assessed by an independent endpoint committee unaware of treatment assignment. The primary endpoint was fatal or disabling stroke in any territory after randomisation to the end of follow-up. Analysis was by intention to treat ([ITT] all patients) and per protocol from 31 days after treatment (all patients in whom assigned treatment was completed). Functional ability was rated with the modified Rankin scale. This study is registered, number ISRCTN25337470. Findings 1713 patients were assigned to stenting (n=855) or endarterectomy (n=858) and followed up for a median of 4·2 years (IQR 3·0–5·2, maximum 10·0). Three patients withdrew immediately and, therefore, the ITT population comprised 1710 patients. The number of fatal or disabling strokes (52 vs 49) and cumulative 5-year risk did not differ significantly between the stenting and endarterectomy groups (6·4% vs 6·5%; hazard ratio [HR] 1·06, 95% CI 0·72–1·57, p=0·77). Any stroke was more frequent in the stenting group than in the endarterectomy group (119 vs 72 events; ITT population, 5-year cumulative risk 15·2% vs 9·4%, HR 1·71, 95% CI 1·28–2·30, p<0·001; per-protocol population, 5-year cumulative risk 8·9% vs 5·8%, 1·53, 1·02–2·31, p=0·04), but were mainly non-disabling strokes. The distribution of modified Rankin scale scores at 1 year, 5 years, or final follow-up did not differ significantly between treatment groups. Interpretation Long-term functional outcome and risk of fatal or disabling stroke are similar for stenting and endarterectomy for symptomatic carotid stenosis. Funding Medical Research Council, Stroke Association, Sanofi-Synthélabo, European Union. PMID:25453443

  11. Rationale and design of the Patient Related OuTcomes with Endeavor versus Cypher stenting Trial (PROTECT): randomized controlled trial comparing the incidence of stent thrombosis and clinical events after sirolimus or zotarolimus drug-eluting stent implantation.

    PubMed

    Camenzind, Edoardo; Wijns, William; Mauri, Laura; Boersma, Eric; Parikh, Keyur; Kurowski, Volkhard; Gao, Runlin; Bode, Christoph; Greenwood, John P; Gershlick, Anthony; O'Neill, William; Serruys, Patrick W; Jorissen, Brenda; Steg, P Gabriel

    2009-12-01

    Drug-eluting stents (DES) reduce restenosis rates compared to bare-metal stents. Most trials using DES enrolled selected patient and lesion subtypes, and primary endpoint focused on angiographic metrics or relatively short-term outcomes. When DES are used in broader types of lesions and patients, important differences may emerge in long-term outcomes between stent types, particularly the incidence of late stent thrombosis. PROTECT is a randomized, open-label trial comparing the long-term safety of the zotarolimus-eluting stent and the sirolimus-eluting stent. The trial has enrolled 8,800 patients representative of those seen in routine clinical practice, undergoing elective, unplanned, or emergency procedures in native coronary arteries in 196 centers in 36 countries. Indications for the procedure and selection of target vessel and lesion characteristics were at the operator's discretion. Procedures could be staged, but no more than 4 target lesions could be treated per patient. Duration of dual antiplatelet therapy was prespecified to achieve similar lengths of treatment in both study arms. The shortest predefined duration was 3 months, as per the manufacturer's instructions. The primary outcome measure is the composite rate of definite and probable stent thrombosis at 3 years, centrally adjudicated using Academic Research Consortium definitions. The main secondary end points are 3-year all-cause mortality, cardiac death, large nonfatal myocardial infarction, and all myocardial infarctions. This large, international, randomized, controlled trial will provide important information on comparative rates of stent thrombosis between 2 different DES systems and safety as assessed by patient-relevant long-term clinical outcomes.

  12. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    PubMed

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  13. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    PubMed

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  14. Direct stenting with a combined intravascular ultrasound-coronary stent delivery platform: a feasibility trial.

    PubMed

    Eeckhout, Eric; Berger, Alexandre; Roguelov, Christan; Lyon, Xavier; Imsand, Christophe; Fivaz-Arbane, Malika; Girod, Grégoire; De Benedetti, Edoardo

    2003-08-01

    IVUS is considered as the most accurate tool for the assessment of optimal stent deployment. Direct stenting has shown to be a safe, efficient, and resource-saving procedure in selected patients. In a prospective 1-month feasibility trial, a new combined IVUS-coronary stent delivery platform (Josonics Flex, Jomed, Helsingborn, Sweden) was evaluated during direct stenting in consecutive patients considered eligible for direct stenting. The feasibility endpoint was successful stent deployment without any clinical adverse event, while the efficacy endpoint was strategic adaptation according to standard IVUS criteria for optimal stent deployment at the intermediate phase (after a result considered angiographically optimal) and at the end of the intervention (after optimization according to IVUS standards). A total of 16 patients were successfully treated with this device without any major clinical complication. At the intermediate phase, optimal stent deployment was achieved in four patients only, while at the end only one patient had nonoptimal IVUS stent deployment. In particular, the minimal in-stent cross-section area increased from 6.3 +/- 1.2 to 8.3 +/- 2.5 mm(2). These preliminary data demonstrate the feasibility of direct stenting with a combined IVUS-stent catheter in selected patients and confirm the results from larger randomized trials on the impact of IVUS on strategic adaptations during coronary stent placement. Copyright 2003 Wiley-Liss, Inc.

  15. Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

    PubMed Central

    Kumar, Sunil; Fusaro, Mario; Amoroso, Nicholas; Kirtane, Ajay J; Byrne, Robert A; Williams, David O; Slater, James; Cutlip, Donald E; Feit, Frederick

    2012-01-01

    Objectives To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. Design Mixed treatment comparison meta-analysis. Data sources and study selection PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. Primary outcomes Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). Results From 42 trials with 22 844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents∼sirolimus eluting stents>paclitaxel eluting stents∼zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of “any” stent thrombosis. Conclusions Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such that the everolimus eluting stent was the most efficacious and safe. PMID:22885395

  16. Efficacy of a dual-ring wound protector for prevention of incisional surgical site infection after Whipple's procedure (pancreaticoduodenectomy) with preoperatively-placed intrabiliary stents: protocol for a randomised controlled trial.

    PubMed

    Bressan, Alexsander K; Roberts, Derek J; Edwards, Janet P; Bhatti, Sana U; Dixon, Elijah; Sutherland, Francis R; Bathe, Oliver; Ball, Chad G

    2014-08-21

    Among surgical oncology patients, incisional surgical site infection is associated with substantially increased morbidity, mortality and healthcare costs. Moreover, while adults undergoing pancreaticoduodenectomy with preoperative placement of an intrabiliary stent have a high risk of this type of infection, and wound protectors may significantly reduce its risk, no relevant studies of wound protectors yet exist involving this patient population. This study will evaluate the efficacy of a dual-ring wound protector for prevention of incisional surgical site infection among adults undergoing pancreaticoduodenectomy with preoperatively-placed intrabiliary stents. This study will be a parallel, dual-arm, randomised controlled trial that will utilise a more explanatory than pragmatic attitude. All adults (≥18 years) undergoing a pancreaticoduodenectomy at the Foothills Medical Centre in Calgary, Alberta, Canada with preoperative placement of an intrabiliary stent will be considered eligible. Exclusion criteria will include patient age <18 years and those receiving long-term glucocorticoids. The trial will employ block randomisation to allocate patients to a commercial dual-ring wound protector (the Alexis Wound Protector) or no wound protector and the current standard of care. The main outcome measure will be the rate of surgical site infection as defined by the Centers for Disease Control and Prevention criteria within 30 days of the index operation date as determined by a research assistant blinded to treatment allocation. Outcomes will be analysed by a statistician blinded to allocation status by calculating risk ratios and 95% CIs and compared using Fisher's exact test. This will be the first randomised trial to evaluate the efficacy of a dual-ring wound protector for prevention of incisional surgical site infection among patients undergoing pancreaticoduodenectomy. Results of this study are expected to be available in 2016/2017 and will be disseminated using an integrated and end-of-grant knowledge translation strategy. ClinicalTrials.gov identifier NCT01836237. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.

    PubMed

    Kandzari, David E; Mauri, Laura; Koolen, Jacques J; Massaro, Joseph M; Doros, Gheorghe; Garcia-Garcia, Hector M; Bennett, Johan; Roguin, Ariel; Gharib, Elie G; Cutlip, Donald E; Waksman, Ron

    2017-10-21

    The development of coronary drug-eluting stents has included use of new metal alloys, changes in stent architecture, and use of bioresorbable polymers. Whether these advancements improve clinical safety and efficacy has not been shown in previous randomised trials. We aimed to examine the clinical outcomes of a bioresorbable polymer sirolimus-eluting stent compared with a durable polymer everolimus-eluting stent in a broad patient population undergoing percutaneous coronary intervention. BIOFLOW V was an international, randomised trial done in patients undergoing elective and urgent percutaneous coronary intervention in 90 hospitals in 13 countries (Australia, Belgium, Canada, Denmark, Germany, Hungary, Israel, the Netherlands, New Zealand, South Korea, Spain, Switzerland, and the USA). Eligible patients were those aged 18 years or older with ischaemic heart disease undergoing planned stent implantation in de-novo, native coronary lesions. Patients were randomly assigned (2:1) to either an ultrathin strut (60 μm) bioresorbable polymer sirolimus-eluting stent or to a durable polymer everolimus-eluting stent. Randomisation was via a central web-based data capture system (mixed blocks of 3 and 6), and stratified by study site. The primary endpoint was 12-month target lesion failure. The primary non-inferiority comparison combined these data from two additional randomised trials of bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent with Bayesian methods. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02389946. Between May 8, 2015, and March 31, 2016, 4772 patients were recruited into the study. 1334 patients met inclusion criteria and were randomly assigned to treatment with bioresorbable polymer sirolimus-eluting stents (n=884) or durable polymer everolimus-eluting stents (n=450). 52 (6%) of 883 patients in the bioresorbable polymer sirolimus-eluting stent group and 41 (10%) of 427 patients in the durable polymer everolimus-eluting stent group met the 12-month primary endpoint of target lesion failure (95% CI -6·84 to -0·29, p=0·0399), with differences in target vessel myocardial infarction (39 [5%] of 831 patients vs 35 [8%] of 424 patients, p=0·0155). The posterior probability that the bioresorbable polymer sirolimus-eluting stent is non-inferior to the durable polymer everolimus-eluting stent was 100% (Bayesian analysis, difference in target lesion failure frequency -2·6% [95% credible interval -5·5 to 0·1], non-inferiority margin 3·85%, n=2208). The outperformance of the ultrathin, bioresorbable polymer sirolimus-eluting stent over the durable polymer everolimus-eluting stent in a complex patient population undergoing percutaneous coronary intervention suggests a new direction in improving next generation drug-eluting stent technology. BIOTRONIK. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial.

    PubMed

    Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W

    2016-11-26

    Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm 2 ), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm 2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm 2 (4·67-7·80) with IVUS guidance, and 5·49 mm 2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm 2 ; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. St Jude Medical. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    PubMed

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p < 0.05) at 12 months. This randomized trial in symptomatic patients with peripheral arterial disease who underwent endovascular treatment for long femoropopliteal lesions demonstrated significant clinical and patency benefits for heparin-bonded covered stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare nitinol stent in the treatment of TASC B, C and D lesions in superficial femoral artery occlusive disease; ISRCTN48164244). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    PubMed

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.

  1. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial.

    PubMed

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-08-11

    The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016-0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial.

    PubMed

    Lal, Brajesh K; Beach, Kirk W; Roubin, Gary S; Lutsep, Helmi L; Moore, Wesley S; Malas, Mahmoud B; Chiu, David; Gonzales, Nicole R; Burke, J Lee; Rinaldi, Michael; Elmore, James R; Weaver, Fred A; Narins, Craig R; Foster, Malcolm; Hodgson, Kim J; Shepard, Alexander D; Meschia, James F; Bergelin, Robert O; Voeks, Jenifer H; Howard, George; Brott, Thomas G

    2012-09-01

    In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63-1·29; p=0·58). Female sex (1·79, 1·25-2·56), diabetes (2·31, 1·61-3·31), and dyslipidaemia (2·07, 1·01-4·26) were independent predictors of restenosis or occlusion after the two procedures. Smoking predicted an increased rate of restenosis after carotid endarterectomy (2·26, 1·34-3·77) but not after carotid artery stenting (0·77, 0·41-1·42). Restenosis and occlusion were infrequent and rates were similar up to 2 years after carotid endarterectomy and carotid artery stenting. Subsets of patients could benefit from early and frequent monitoring after revascularisation. National Institute of Neurological Disorders and Stroke and Abbott Vascular Solutions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial

    PubMed Central

    Lal, Brajesh K.; Beach, Kirk W.; Roubin, Gary S.; Lutsep, Helmi L.; Moore, Wesley S.; Malas, Mahmoud B.; Chiu, David; Gonzales, Nicole R.; Burke, J. Lee; Rinaldi, Michael; Elmore, James R.; Weaver, Fred A.; Narins, Craig R.; Foster, Malcolm; Hodgson, Kim J.; Shepard, Alexander D.; Meschia, James F.; Bergelin, Robert O.; Voeks, Jenifer H.; Howard, George; Brott, Thomas G.

    2012-01-01

    Background In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Methods Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. Findings 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63–1·29; p=0·58). Female sex (1·79, 1·25–2·56), diabetes (2·31, 1·61–3·31), and dyslipidaemia (2·07, 1·01–4·26) were independent predictors of restenosis or occlusion after the two procedures. Smoking predicted an increased rate of restenosis after carotid endarterectomy (2·26, 1·34–3·77) but not after carotid artery stenting (0·77, 0·41–1·42). Interpretation Restenosis and occlusion were infrequent and rates were similar up to 2 years after carotid endarterectomy and carotid artery stenting. Subsets of patients could benefit from early and frequent monitoring after revascularisation. Funding National Institute of Neurological Disorders and Stroke and Abbott Vascular Solutions PMID:22857850

  4. Current evidence for the safety and efficacy of the bio-engineered dual therapy COMBO stent.

    PubMed

    Kalkman, Deborah N; Chandrasekhar, Jaya; de Winter, Robbert J; Mehran, Roxana

    2018-06-01

    The novel dual-therapy COMBO stent aims to promote vessel healing after percutaneous coronary intervention (PCI) in patients with coronary artery disease. The pro-healing technique consists of an anti-CD34+ antibody layer that attracts circulating endothelial progenitor cells (EPCs), which bind to the stent surface and allow rapid endothelialization by differentiation of the EPCs into normal endothelial cells. The COMBO stent combines this pro-healing technique with an abluminal drug elution of sirolimus. The promise of this dual-therapy stent is that it may safely allow a shortened duration of dual-antiplatelet therapy (DAPT) after stent placement. Moreover, with a mature endothelial layer, lower rates of in-stent restenosis may be expected. Clinical outcomes after COMBO stent implantation have been recently evaluated in both randomized trials and large, prospective, multicenter registries, showing low clinical event rates of in-stent restenosis and stent thrombosis. Randomized clinical trials (HARMONEE and RECOVERY) have demonstrated the non-inferiority of COMBO versus "first in class" second generation and newer generation drug-eluting stents. Safety and efficacy of 3 months of DAPT after COMBO stent placement in patients presenting with acute coronary syndrome has been evaluated in the large REDUCE randomized controlled trial, showing non-inferiority to standard duration of 12-month DAPT. In this review we provide an overview of the current pre-clinical and clinical evidence for the performance of the COMBO stent.

  5. Effect of white-matter lesions on the risk of periprocedural stroke after carotid artery stenting versus endarterectomy in the International Carotid Stenting Study (ICSS): a prespecified analysis of data from a randomised trial

    PubMed Central

    Ederle, Jörg; Davagnanam, Indran; van der Worp, H Bart; Venables, Graham S; Lyrer, Philippe A; Featherstone, Roland L; Brown, Martin M; Jäger, H Rolf

    2013-01-01

    Summary Background Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid endarterectomy. Methods Patients with symptomatic carotid artery stenosis included in the International Carotid Stenting Study (ICSS) were randomly allocated to receive carotid artery stenting or carotid endarterectomy. Copies of baseline brain imaging were analysed by two investigators, who were masked to treatment, for the severity of white-matter lesions using the age-related white-matter changes (ARWMC) score. Randomisation was done with a computer-generated sequence (1:1). Patients were divided into two groups using the median ARWMC. We analysed the risk of stroke within 30 days of revascularisation using a per-protocol analysis. ICSS is registered with controlled-trials.com, number ISRCTN 25337470. Findings 1036 patients (536 randomly allocated to carotid artery stenting, 500 to carotid endarterectomy) had baseline imaging available. Median ARWMC score was 7, and patients were dichotomised into those with a score of 7 or more and those with a score of less than 7. In patients treated with carotid artery stenting, those with an ARWMC score of 7 or more had an increased risk of stroke compared with those with a score of less than 7 (HR for any stroke 2·76, 95% CI 1·17–6·51; p=0·021; HR for non-disabling stroke 3·00, 1·10–8·36; p=0·031), but we did not see a similar association in patients treated with carotid endarterectomy (HR for any stroke 1·18, 0·40–3·55; p=0·76; HR for disabling or fatal stroke 1·41, 0·38–5·26; p=0·607). Carotid artery stenting was associated with a higher risk of stroke compared with carotid endarterectomy in patients with an ARWMC score of 7 or more (HR for any stroke 2·98, 1·29–6·93; p=0·011; HR for non-disabling stroke 6·34, 1·45–27·71; p=0·014), but there was no risk difference in patients with an ARWMC score of less than 7. Interpretation The presence of white-matter lesions on brain imaging should be taken into account when selecting patients for carotid revascularisation. Carotid artery stenting should be avoided in patients with more extensive white-matter lesions, but might be an acceptable alternative to carotid endarterectomy in patients with less extensive lesions. Funding Medical Research Council, the Stroke Association, Sanofi-Synthélabo, the European Union Research Framework Programme 5. PMID:23849948

  6. Effect of white-matter lesions on the risk of periprocedural stroke after carotid artery stenting versus endarterectomy in the International Carotid Stenting Study (ICSS): a prespecified analysis of data from a randomised trial.

    PubMed

    Ederle, Jörg; Davagnanam, Indran; van der Worp, H Bart; Venables, Graham S; Lyrer, Philippe A; Featherstone, Roland L; Brown, Martin M; Jäger, H Rolf

    2013-09-01

    Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid endarterectomy. Patients with symptomatic carotid artery stenosis included in the International Carotid Stenting Study (ICSS) were randomly allocated to receive carotid artery stenting or carotid endarterectomy. Copies of baseline brain imaging were analysed by two investigators, who were masked to treatment, for the severity of white-matter lesions using the age-related white-matter changes (ARWMC) score. Randomisation was done with a computer-generated sequence (1:1). Patients were divided into two groups using the median ARWMC. We analysed the risk of stroke within 30 days of revascularisation using a per-protocol analysis. ICSS is registered with controlled-trials.com, number ISRCTN 25337470. 1036 patients (536 randomly allocated to carotid artery stenting, 500 to carotid endarterectomy) had baseline imaging available. Median ARWMC score was 7, and patients were dichotomised into those with a score of 7 or more and those with a score of less than 7. In patients treated with carotid artery stenting, those with an ARWMC score of 7 or more had an increased risk of stroke compared with those with a score of less than 7 (HR for any stroke 2·76, 95% CI 1·17-6·51; p=0·021; HR for non-disabling stroke 3·00, 1·10-8·36; p=0·031), but we did not see a similar association in patients treated with carotid endarterectomy (HR for any stroke 1·18, 0·40-3·55; p=0·76; HR for disabling or fatal stroke 1·41, 0·38-5·26; p=0·607). Carotid artery stenting was associated with a higher risk of stroke compared with carotid endarterectomy in patients with an ARWMC score of 7 or more (HR for any stroke 2·98, 1·29-6·93; p=0·011; HR for non-disabling stroke 6·34, 1·45-27·71; p=0·014), but there was no risk difference in patients with an ARWMC score of less than 7. The presence of white-matter lesions on brain imaging should be taken into account when selecting patients for carotid revascularisation. Carotid artery stenting should be avoided in patients with more extensive white-matter lesions, but might be an acceptable alternative to carotid endarterectomy in patients with less extensive lesions. Medical Research Council, the Stroke Association, Sanofi-Synthélabo, the European Union Research Framework Programme 5. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial.

    PubMed

    Bonati, Leo H; Dobson, Joanna; Featherstone, Roland L; Ederle, Jörg; van der Worp, H Bart; de Borst, Gert J; Mali, Willem P Th M; Beard, Jonathan D; Cleveland, Trevor; Engelter, Stefan T; Lyrer, Philippe A; Ford, Gary A; Dorman, Paul J; Brown, Martin M

    2015-02-07

    Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. Patients with symptomatic carotid stenosis were randomly assigned 1:1 to open treatment with stenting or endarterectomy at 50 centres worldwide. Randomisation was computer generated centrally and allocated by telephone call or fax. Major outcomes were assessed by an independent endpoint committee unaware of treatment assignment. The primary endpoint was fatal or disabling stroke in any territory after randomisation to the end of follow-up. Analysis was by intention to treat ([ITT] all patients) and per protocol from 31 days after treatment (all patients in whom assigned treatment was completed). Functional ability was rated with the modified Rankin scale. This study is registered, number ISRCTN25337470. 1713 patients were assigned to stenting (n=855) or endarterectomy (n=858) and followed up for a median of 4·2 years (IQR 3·0-5·2, maximum 10·0). Three patients withdrew immediately and, therefore, the ITT population comprised 1710 patients. The number of fatal or disabling strokes (52 vs 49) and cumulative 5-year risk did not differ significantly between the stenting and endarterectomy groups (6·4% vs 6·5%; hazard ratio [HR] 1·06, 95% CI 0·72-1·57, p=0·77). Any stroke was more frequent in the stenting group than in the endarterectomy group (119 vs 72 events; ITT population, 5-year cumulative risk 15·2% vs 9·4%, HR 1·71, 95% CI 1·28-2·30, p<0·001; per-protocol population, 5-year cumulative risk 8·9% vs 5·8%, 1·53, 1·02-2·31, p=0·04), but were mainly non-disabling strokes. The distribution of modified Rankin scale scores at 1 year, 5 years, or final follow-up did not differ significantly between treatment groups. Long-term functional outcome and risk of fatal or disabling stroke are similar for stenting and endarterectomy for symptomatic carotid stenosis. Medical Research Council, Stroke Association, Sanofi-Synthélabo, European Union. Copyright © 2015 Bonati et al. Open Access article distributed under the terms of CC BY. Published by Elsevier Ltd. All rights reserved.

  8. Cost-effectiveness and clinical efficacy of biliary stents in patients undergoing neoadjuvant therapy for pancreatic adenocarcinoma in a randomized controlled trial.

    PubMed

    Gardner, Timothy B; Spangler, Chad C; Byanova, Katerina L; Ripple, Gregory H; Rockacy, Matthew J; Levenick, John M; Smith, Kerrington D; Colacchio, Thomas A; Barth, Richard J; Zaki, Bassem I; Tsapakos, Michael J; Gordon, Stuart R

    2016-09-01

    The optimal type of stent for the palliation of malignant biliary obstruction in patients with pancreatic adenocarcinoma undergoing neoadjuvant chemoradiotherapy with curative intent is unknown. We performed a prospective trial comparing 3 types of biliary stents-fully covered self-expandable metal (fcSEMS), uncovered self-expandable metal (uSEMS), and plastic-to determine which best optimized cost-effectiveness and important clinical outcomes. In this prospective randomized trial, consecutive patients with malignant biliary obstruction from newly diagnosed pancreatic adenocarcinoma who were to start neoadjuvant chemoradiotherapy were randomized to receive fcSEMSs, uSEMSs, or plastic stents during the index ERCP. The primary outcomes were time to stent occlusion, attempted surgical resection, or death after the initiation of neoadjuvant therapy, and the secondary outcomes were total patient costs associated with the stent, including the index ERCP cost, downstream hospitalization cost due to stent occlusion, and the cost associated with procedural adverse event. Fifty-four patients were randomized and reached the primary end point: 16 in the fcSEMS group, 17 in the uSEMS group, and 21 in the plastic stent group. No baseline demographic or tumor characteristic differences were noted among the groups. The fcSEMSs had a longer time to stent occlusion compared with uSEMSs and plastic stents (220 vs 74 and 76 days, P < .01), although the groups had equivalent rates of stent occlusion, attempted surgical resection, and death. Although SEMS placement cost more during the index ERCP (uSEMS = $24,874 and fcSEMS = $22,729 vs plastic = $18,701; P < .01), they resulted in higher procedural AE costs per patient (uSEMS = $5522 and fcSEMS = $12,701 vs plastic = $0; P < .01). Conversely, plastic stents resulted in an $11,458 hospitalization cost per patient due to stent occlusion compared with $2301 for uSEMSs and $0 for fcSEMSs (P < .01). In a prospective trial comparing fcSEMSs, uSEMSs, and plastic stents for malignant biliary obstruction in patients undergoing neoadjuvant therapy with curative intent for pancreatic adenocarcinoma, no stent type was superior in optimizing cost-effectiveness, although fcSEMSs resulted in fewer days of neoadjuvant treatment delay and a longer time to stent occlusion. (Clincial trial registration number: NCT01038713.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. New-generation stents compared with coronary bypass surgery for unprotected left main disease: A word of caution.

    PubMed

    Benedetto, Umberto; Taggart, David P; Sousa-Uva, Miguel; Biondi-Zoccai, Giuseppe; Di Franco, Antonino; Ohmes, Lucas B; Rahouma, Mohamed; Kamel, Mohamed; Caputo, Massimo; Girardi, Leonard N; Angelini, Gianni D; Gaudino, Mario

    2018-05-01

    With the advent of bare metal stents and drug-eluting stents, percutaneous coronary intervention has emerged as an alternative to coronary artery bypass grafting surgery for unprotected left main disease. However, whether the evolution of stents technology has translated into better results after percutaneous coronary intervention remains unclear. We aimed to compare coronary artery bypass grafting with stents of different generations for left main disease by performing a Bayesian network meta-analysis of available randomized controlled trials. All randomized controlled trials with at least 1 arm randomized to percutaneous coronary intervention with stents or coronary artery bypass grafting for left main disease were included. Bare metal stents and drug-eluting stents of first- and second-generation were compared with coronary artery bypass grafting. Poisson methods and Bayesian framework were used to compute the head-to-head incidence rate ratio and 95% credible intervals. Primary end points were the composite of death/myocardial infarction/stroke and repeat revascularization. Nine randomized controlled trials were included in the final analysis. Six trials compared percutaneous coronary intervention with coronary artery bypass grafting (n = 4654), and 3 trials compared different types of stents (n = 1360). Follow-up ranged from 6 months to 5 years. Second-generation drug-eluting stents (incidence rate ratio, 1.3; 95% credible interval, 1.1-1.6), but not bare metal stents (incidence rate ratio, 0.63; 95% credible interval, 0.27-1.4), and first-generation drug-eluting stents (incidence rate ratio, 0.85; 95% credible interval, 0.65-1.1) were associated with a significantly increased risk of death/myocardial infarction/stroke when compared with coronary artery bypass grafting. When compared with coronary artery bypass grafting, the highest risk of repeat revascularization was observed for bare metal stents (hazard ratio, 5.1; 95% confidence interval, 2.1-14), whereas first-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) and second-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) were comparable. The introduction of new-generation drug-eluting stents did not translate into better outcomes for percutaneous coronary intervention when compared with coronary artery bypass grafting. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  10. Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lammer, Johannes, E-mail: jlammer@gmx.at, E-mail: johannes.lammer@meduniwien.ac.at; Zeller, Thomas, E-mail: thomas.zeller@universitaets-herzzentrum.de; Hausegger, Klaus A., E-mail: klaus.hausegger@lkh-klu.at

    PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} andmore » BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)« less

  11. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    PubMed

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to mitigate the increased risk of stent thrombosis associated with ACS. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions [SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT III]; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT IV]; NCT00307047; A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice: the COMPARE Trial [COMPARE]; NCT01016041). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Stenting for symptomatic vertebral artery stenosis: The Vertebral Artery Ischaemia Stenting Trial.

    PubMed

    Markus, Hugh S; Larsson, Susanna C; Kuker, Wilhelm; Schulz, Ursula G; Ford, Ian; Rothwell, Peter M; Clifton, Andrew

    2017-09-19

    To compare in the Vertebral Artery Ischaemia Stenting Trial (VIST) the risks and benefits of vertebral angioplasty and stenting with best medical treatment (BMT) alone for symptomatic vertebral artery stenosis. VIST was a prospective, randomized, open-blinded endpoint clinical trial performed in 14 hospitals in the United Kingdom. Participants with symptomatic vertebral stenosis ≥50% were randomly assigned (1:1) to vertebral angioplasty/stenting plus BMT or to BMT alone with randomization stratified by site of stenosis (extracranial vs intracranial). Because of slow recruitment and cessation of funding, recruitment was stopped after 182 participants. Follow-up was a minimum of ≥1 year for each participant. Three patients did not contribute any follow-up data and were excluded, leaving 91 patients in the stent group and 88 in the medical group. Mean follow-up was 3.5 (interquartile range 2.1-4.7) years. Of 61 patients who were stented, stenosis was extracranial in 48 (78.7%) and intracranial in 13 (21.3%). No periprocedural complications occurred with extracranial stenting; 2 strokes occurred during intracranial stenting. The primary endpoint of fatal or nonfatal stroke occurred in 5 patients in the stent group vs 12 in the medical group (hazard ratio 0.40, 95% confidence interval 0.14-1.13, p = 0.08), with an absolute risk reduction of 25 strokes per 1,000 person-years. The hazard ratio for stroke or TIA was 0.50 ( p = 0.05). Stenting in extracranial stenosis appears safe with low complication rates. Large phase 3 trials are required to determine whether stenting reduces stroke risk. ISRCTN95212240. This study provides Class I evidence that for patients with symptomatic vertebral stenosis, angioplasty with stenting does not reduce the risk of stroke. However, the study lacked the precision to exclude a benefit from stenting. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  13. The Carotid Revascularization Endarterectomy vs. Stenting Trial completes randomization: lessons learned and anticipated results.

    PubMed

    Lal, Brajesh K; Brott, Thomas G

    2009-11-01

    The Carotid Revascularization Endarterectomy vs. Stenting Trial (CREST) completed randomization on July 18, 2008. Sponsored by the National Institute of Neurological Disorders and Stroke (NINDS), the trial has enrolled 2,522 participants across North America and is the largest randomized clinical trial (RCT) comparing the efficacy of carotid artery stenting (CAS) to carotid endarterectomy (CEA). It is also the largest RCT to assess carotid revascularization in both symptomatic and asymptomatic patients with carotid artery stenosis. Conventional-risk patients with symptomatic carotid stenosis (> or =50% by angiography, > or =70% by ultrasound) or asymptomatic carotid stenosis (> or =60% by angiography, > or =70% by ultrasound) were randomized to both treatment arms in a 1:1 ratio. Eligibility criteria for CREST were similar to those of the previous NINDS-sponsored CEA RCTs. The investigational devices used in the CAS arm of the study are the RX Acculink stent and the RX Accunet embolic protection system, (Abbott Vascular, Santa Clara, Calif). The primary aim is to contrast the efficacy of CAS versus CEA in preventing stroke, myocardial infarction, and all-cause mortality during a 30-day peri-procedural period, and ipsilateral stroke over the follow-up period (extending up to four years). The secondary aims are to contrast the efficacy of CAS and CEA in men and women, the restenosis rates of the two procedures, health-related quality of life, and cost effectiveness of CAS and CEA. The conclusion of enrollment in CREST marks the end of a long recruitment period from 117 community and academic hospital centers across the United States and Canada. Each surgeon and interventionalist underwent a rigorous credentialing process that included performance-assessment of prior CEA and CAS procedures. Credentialing of interventionalists also included a review of additional CAS procedures enrolled into a CREST lead-in phase prior to entering patients into the randomized trial; 1564 patients were enrolled in the lead-in, the final pathway for the largest credentialing effort to date for any clinical trial. CREST will provide long-term follow-up after carotid revascularization based on systematic ultrasonographic and neurologic surveillance, and on quality of life and cost-effectiveness comparisons between CAS and CEA in the setting of a RCT. We present a brief description of the CREST protocol, impediments that were overcome during the trial, salient results from the lead-in phase of the trial, a summary of enrollment activities and characteristics of the final cohort, and a timeline for anticipated results from the randomized phase.

  14. Perioperative antiplatelet management in patients with coronary artery stenting.

    PubMed

    Tandar, Anwar; Velagapudi, Krishna N; Wilson, Brent D; Boden, William E

    2012-04-01

    Coronary artery disease is the primary cause of mortality in men and women in the United States. Transcatheter coronary intervention is the mainstay of treatment for patients with acute coronary artery disease presentations and patients with stable disease. Although percutaneous intervention initially only included balloon angioplasty, it now typically involves the placement of intracoronary stents. To overcome the limitations of bare-metal stents, namely in-stent restenosis, stents have been developed that remove pharmaceuticals that reduce neointimal hyperplasia and in-stent restenosis. However, these pharmaceutical agents also delay stent endothelialization, posing a prolonged risk of in situ thrombosis. Placement of an intracoronary stent (eg, bare-metal or drug-eluting stent) requires dual antiplatelet therapy to prevent the potentially life-threatening complication of stent thrombosis. The optimal duration of dual antiplatelet therapy following stent placement is unknown. This article discusses the factors to be considered when deciding when dual antiplatelet therapy can be safely discontinued. Unfortunately, in the hospital setting, this decision to interrupt dual antiplatelet therapy frequently must be made shortly after stent placement because of unanticipated surgical procedures or other unforeseen complications. The decision of when dual antiplatelet therapy can be safely interrupted needs to be individualized for each patient and involves factoring in the type of stent; the location and complexity of the lesion stented; post-stent lesion characteristics; the amount of time since stent placement; and the antiplatelet regimen currently in use, along with its implication for bleeding during the proposed procedure. Having a protocol in place, such as the protocol described in this article, can help guide this decision-making process and avoid confusion and potential error.

  15. A prospective randomised trial comparing the novel ridaforolimus-eluting BioNIR stent to the zotarolimus-eluting Resolute stent: six-month angiographic and one-year clinical results of the NIREUS trial.

    PubMed

    Paradies, Valeria; Ben-Yehuda, Ori; Jonas, Michael; Banai, Shmuel; Iñiguez, Andres; Perlman, Gidon Y; Kandzari, David E; Stone, Gregg W; Smits, Pieter C

    2018-05-20

    The aim of this study was to evaluate the efficacy and safety of the BioNIR stent compared with the Resolute Integrity stent for the treatment of coronary artery disease. This first-in-human, multicentre, single-blind randomised non-inferiority trial was performed in Europe and Israel. Patients with stable coronary artery disease or acute coronary syndromes were randomly assigned to treatment with BioNIR or Resolute Integrity stents in a 2:1 fashion. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Three hundred and two patients were randomised, of whom 261 (86.0%) underwent six-month angiographic follow-up. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of in-stent LLL at six months (0.04±0.30 mm vs. 0.03±0.31 mm, respectively, pnoninferiority<0.0001). At 12-month follow-up, target lesion failure occurred in 3.4% in the BioNIR group and 5.9% in the Resolute Integrity group (p=0.22). Rates of MACE were similar between the BioNIR and Resolute Integrity groups (4.3% vs. 5.9%, respectively, p=0.45). The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of angiographic in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  16. Direct comparison of the short-term clinical performance of Z Guidant and Taxus stents.

    PubMed

    Guildford, Anna; Colombo, Paola; Bruschi, Giuseppe; Bonacina, Edgardo; Klugmann, Silvio; Santin, Matteo

    2010-12-03

    The recent introduction of drug-eluting stents in angioplasty of atherosclerotic blood vessels has significantly reduced the risks of in-stent restenosis (ISR) [1]. Indeed, it is known that in conventional stents ISR takes place in over 20% of the cases and up to 60% when implanted in diabetic patients. Conversely, clinical trials have shown that drug-eluting stents have significantly reduced ISR. Among the drug-eluting stents available on the market, Taxus stents (Tax, Boston Scientific, USA) are among the most used devices [2]. Tax are stainless-steel stents coated with Translute, a poly(styrene-b-isobutylene-b-styrene) polymer (PSIBS) eluting Placlitaxel, an anti-mitotic drug. Clinical trials on this type of drug-eluting stents have shown an incidence of restenosis of approximately 4%. The majority of these trials were randomized studies where conventional stents and drug-eluting devices have been implanted in separate patients' cohorts. Such a randomized design, although fundamental to collect statistically-relevant data, does not allow a direct histological comparison of different stent types when implanted in the same patient and do not show the individual susceptibility to the host response especially at short-term implantation times. Here, an interesting case study is presented where two chrome-cobalt stents (Z Guidant, ZG, Guidant Corp.) and a Tax have been simultaneously implanted in the same patient in three separate coronary arteries, retrieved after only 8 weeks and histologically analysed. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Percutaneous Coronary Intervention of Left Main Disease: Pre- and Post-EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) Era.

    PubMed

    Park, Duk-Woo; Park, Seung-Jung

    2017-06-01

    For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.

  18. Ab interno trabecular bypass surgery with iStent for open angle glaucoma

    PubMed Central

    Le, Jimmy T; Bicket, Amanda K; Li, Tianjing

    2018-01-01

    This is a protocol for a Cochrane Review (Intervention). The objectives are as follows: The primary objective is to assess the comparative effectiveness and safety of ab interno trabecular bypass surgery with iStent or iStent inject for OAG in comparison to conventional medical, laser, or surgical treatment. A secondary objective is to examine the effectiveness and safety of iStent or iStent Inject surgery in people who have concomitant phacoemulsification. PMID:27526051

  19. Retrograde pyelography predicts retrograde ureteral stenting failure and reduces unnecessary stenting trials in patients with advanced non-urological malignant ureteral obstruction

    PubMed Central

    Kim, Sung Han; Park, Boram; Joo, Jungnam; Joung, Jae Young; Seo, Ho Kyung; Chung, Jinsoo; Lee, Kang Hyun

    2017-01-01

    Objective To evaluate predictive factors for retrograde ureteral stent failure in patients with non-urological malignant ureteral obstruction. Materials and methods Between 2005 and 2014, medical records of 284 malignant ureteral obstruction patients with 712 retrograde ureteral stent trials including 63 (22.2%) having bilateral malignant ureteral obstruction were retrospectively reviewed. Retrograde ureteral stent failure was defined as the inability to place ureteral stents by cystoscopy, recurrent stent obstruction within one month, or non-relief of azotemia within one week from the prior retrograde ureteral stent. The clinicopathological parameters and first retrograde pyelographic findings were analyzed to investigate the predictive factors for retrograde ureteral stent failure and conversion to percutaneous nephrostomy in multivariate analysis with a statistical significance of p < 0.05. Results Retrograde ureteral stent failure was detected in 14.1% of patients. The mean number of retrograde ureteral stent placements and indwelling duration of the ureteral stents were 2.5 ± 2.6 times and 8.6 ± 4.0 months, respectively. Multivariate analyses identified several specific RGP findings as significant predictive factors for retrograde ureteral stent failure (p < 0.05). The significant retrograde pyelographic findings included grade 4 hydronephrosis (hazard ratio 4.10, 95% confidence interval 1.39–12.09), irreversible ureteral kinking (hazard ratio 2.72, confidence interval 1.03–7.18), presence of bladder invasion (hazard ratio 4.78, confidence interval 1.81–12.63), and multiple lesions of ureteral stricture (hazard ratio 3.46, confidence interval 1.35–8.83) (p < 0.05). Conclusion Retrograde pyelography might prevent unnecessary and ineffective retrograde ureteral stent trials in patients with advanced non-urological malignant ureteral obstruction. PMID:28931043

  20. A randomised comparison of Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion: rationale and design of the CIT-RESOLVE trial

    PubMed Central

    Zhang, Dong; Yin, Dong; Song, Chenxi; Zhu, Chengang; Kirtane, Ajay J; Xu, Bo; Dou, Kefei

    2017-01-01

    Introduction The intentional strategy (aggressive side branch (SB) protection strategy: elective two-stent strategy or jailed balloon technique) is thought to be associated with lower SB occlusion rate than conventional strategy (provisional two-stent strategy or jailed wire technique). However, most previous studies showed comparable outcomes between the two strategies, probably due to no risk classification of SB occlusion when enrolling patients. There is still no randomised trial compared the intentional and conventional strategy when treating bifurcation lesions with high risk of SB occlusion. We aim to investigate if intentional strategy is associated with significant reduction of SB occlusion rate compared with conventional strategy in high-risk patients. Methods and analysis The Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion (CIT-RESOLVE) is a prospective, randomised, single-blind, multicentre clinical trial comparing the rate of SB occlusion between the intentional strategy group and the conventional strategy group (positive control group) in a consecutive cohort of patients with high risk of side branch occlusion defined by V-RESOLVE score, which is a validated angiographic scoring system to evaluate the risk of SB occlusion in bifurcation intervention and used as one of the inclusion criteria to select patients with high SB occlusion risk (V-RESOLVE score ≥12). A total of 21 hospitals from 10 provinces in China participated in the present study. 566 patients meeting all inclusion/exclusion criteria are randomised to either intentional strategy group or conventional strategy group. The primary endpoint is SB occlusion (defined as any decrease in thrombolysis in myocardial infarction flow grade or absence of flow in SB after main vessel stenting). All patients are followed up for 12-month postdischarge. Ethics and dissemination The protocol has been approved by all local ethics committee. The ethics committee have approved the study protocol, evaluated the risk to benefit ratio, allowed operators with a minimum annual volume of 200 cases to participate in the percutaneous coronary intervention procedure and permitted them to perform both conventional and intentional strategies. Written informed consent would be acquired from all participants. The findings of the trial will be shared by the participant hospitals and disseminated through peer-reviewed journals. Trial registration number NCT02644434; Pre-results. PMID:28606906

  1. Short-Term Use of Uncovered Self-Expanding Metallic Airway Stents for Severe Expiratory Central Airway Collapse.

    PubMed

    Majid, Adnan; Alape, Daniel; Kheir, Fayez; Folch, Erik; Ochoa, Sebastian; Folch, Alejandro; Gangadharan, Sidhu P

    2016-01-01

    Patients with severe symptomatic expiratory central airway collapse (ECAC) undergo a stent trial to determine whether they are candidate for tracheobronchoplasty. Most stent trials were done using silicone stents. However, there was a higher number of silicone stent-related complications. The aim of this study was to evaluate the safety and efficacy of short-term uncovered self-expanding metallic airway stents (USEMAS) in patients with ECAC. This was a retrospective review. Baseline measurements were compared to those obtained after 7-14 days. Measurements included: Modified Medical Research Council (mMRC), Cough Quality of Life Questionnaire (CQLQ), spirometry testing, and 6-Minute Walk Test (6MWT). Stent- and procedure-related complications were reported. 33 patients (median age, 52 years) underwent the USEMAS trial. Presenting symptoms were dyspnea in 100%, intractable cough in 90.3%, recurrent infection in 42.2%, and inability to clear secretions in 21.4%. Dyspnea, cough, and secretion clearance improved in 88, 70, and 57%, respectively. Overall, there was a significant improvement in mMRC (p < 0.001), CQLQ (p = 0.015), and 6MWT (p = 0.015). There was 1 airway infection, 1 stent migration, and 1 pneumothorax. The median duration of USEMAS was 7 days. All stents were removed without any complications. At the time of stent removal, no granulation tissue was observed in 30.9%, and mild granulation tissue was observed in 69.1%. The short-term USEMAS trial improves respiratory symptoms, quality of life, and exercise capacity with few complications in patients with severe symptomatic ECAC when performed by a multidisciplinary airway team in highly specialized centers with experience in the evaluation and treatment of this patient population. © 2016 S. Karger AG, Basel.

  2. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.

    PubMed

    Muramatsu, Takashi; Onuma, Yoshinobu; van Geuns, Robert-Jan; Chevalier, Bernard; Patel, Tejas M; Seth, Ashok; Diletti, Roberto; García-García, Hector M; Dorange, Cécile C; Veldhof, Susan; Cheong, Wai-Fung; Ozaki, Yukio; Whitbourn, Robert; Bartorelli, Antonio; Stone, Gregg W; Abizaid, Alexandre; Serruys, Patrick W

    2014-05-01

    The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). Clinical outcomes of diabetic patients after BVS implantation have been unreported. This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and diabetic patients treated with EES at 1-year follow-up. (ABSORB Clinical Investigation, Cohort B; NCT00856856; ABSORB EXTEND Clinical Investigation; NCT01023789; Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT FIRST]; NCT00180453; A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT II]; NCT00180310; Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System [EECSS] [SPIRIT III]; NCT00180479; Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT IV Clinical Trial]; NCT00307047). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Trials and tribulations of carotid artery stenting: The Interventionalists' perspective on SAPPHIRE, EVA-3S, and SPACE Trials.

    PubMed

    Harjai, Kishore J; Mehta, Rajendra H

    2007-10-01

    Three recently completed randomized studies of carotid artery stenting (CAS) versus endarterectomy-Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy (SAPPHIRE), Endarterectomy versus Stenting in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S), and Stent-Supported Percutaneous Angioplasty of the Carotid Artery versus Endarterectomy (SPACE)-reached vividly different conclusions about the safety of stenting versus endarterectomy. The methodologies of these studies differed from each other in many respects. In an attempt to explain the disparate results of SAPPHIRE, EVA-3S, and SPACE, this focused review compares and contrasts these studies, with specific reference to inclusion and exclusion criteria, technical considerations, and the experience level of the interventional operators.

  4. A comparison of direct aspiration versus stent retriever as a first approach ('COMPASS'): protocol.

    PubMed

    Turk, Aquilla S; Siddiqui, Adnan H; Mocco, J

    2018-02-20

    Acute ischemic stroke is a potentially devastating condition and leading cause of morbidity and mortality, affecting an estimated 800 000 people per year in the USA. The natural history of untreated or unrevascularized large vessel occlusions in acute stroke patients results in mortality rates approaching 30%, with only 25% achieving good neurologic outcomes at 90 days. Recently, data have demonstrated that early endovascular recanalization of large vessel occlusions results in better outcomes than medical therapy alone. However, the majority of patients in these studies were treated with a stent retriever based approach. The purpose of COMPASS is to evaluate whether patients treated with a direct aspiration first pass (ADAPT) approach have non-inferior functional outcomes to those treated with a stent retriever as the firstline (SRFL) approach. All patients who meet the inclusion and exclusion criteria and consent to participate will be enrolled at participating centers. Treatment will be randomly assigned by a central web based system in a 1:1 manner to treatment with either ADAPT or SRFL thrombectomy. Statistical methodology is prespecified with details available in the statistical analysis plan. The trial recently completed enrollment, and data collection/verification is ongoing. The final results will be made available on completion of enrollment and follow-up. This paper details the design of the COMPASS trial, a randomized, blinded adjudicator, concurrent, controlled trial of patients treated with either ADAPT or SRFL approaches in order to evaluate whether ADAPT results in non-inferior functional outcome. NCT02466893, Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    PubMed

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels <3.0 mm (n=209) and type B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, p<0.001; long lesions 0.13+/-0.26 mm versus 0.43+/-0.46 mm, p=0.070; small vessels 0.17+/-0.28 mm versus 0.37+/-0.39 mm, p<0.001; B2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, p<0.001. The everolimus-eluting stent remained superior in terms of in-stent late loss in a variety of higher risk populations for restenosis compared to the paclitaxel-eluting stent. These analyses were consistent with the in-stent late loss results of the overall SPIRIT II trial population.

  6. Economic evaluation of drug-eluting stents in coronary angioplasty.

    PubMed

    Santos, Ricardo; Pereira, Hélder

    2005-11-01

    Coronary angioplasty has revolutionized the treatment of coronary artery disease, from the first balloon angioplasty to the current era of drug-eluting stents (DES), which were developed to eliminate the bare metal stent's (BMS) Achilles' heel, restenosis. DES have an extremely low restenosis rate but are significantly more expensive and need more prolonged dual antiplatelet therapy. Restenosis has a generally benign prognosis and is not associated with higher mortality or major adverse cardiovascular events, which has limited the penetration of DES, whose only advantage is the reduction of restenosis. Economic evaluation of DES is therefore of paramount importance for assessing their appropriate use. In randomized trials in which they are compared with BMS, economic evaluation is advantageous for DES, with good cost-effectiveness ratios for both cost per quality-adjusted life year (QALY) and cost per revascularization avoided. However, these trials have two major limitations--the angiographic follow-up protocol and selection of patients with lower risk--and so their results do not accurately reflect reality. Other studies with unselected populations and cost-effectiveness models show that there is an economic advantage in the use of DES in groups with higher risk of restenosis, but not for the whole population undergoing angioplasty. Use of DES will be more appropriate if we can identify populations with a higher likelihood of restenosis, because these are the patients that will benefit most from their use and in whom they will be economically advantageous.

  7. Assessment of In-Stent Restenosis Using 64-MDCT: Analysis of the CORE-64 Multicenter International Trial

    PubMed Central

    Wykrzykowska, Joanna J.; Arbab-Zadeh, Armin; Godoy, Gustavo; Miller, Julie M.; Lin, Shezhang; Vavere, Andrea; Paul, Narinder; Niinuma, Hiroyuki; Hoe, John; Brinker, Jeffrey; Khosa, Faisal; Sarwar, Sheryar; Lima, Joao; Clouse, Melvin E.

    2012-01-01

    OBJECTIVE Evaluations of stents by MDCT from studies performed at single centers have yielded variable results with a high proportion of unassessable stents. The purpose of this study was to evaluate the accuracy of 64-MDCT angiography (MDCTA) in identifying in-stent restenosis in a multicenter trial. MATERIALS AND METHODS The Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography Using 64 Detectors (CORE-64) Multicenter Trial and Registry evaluated the accuracy of 64-MDCTA in assessing 405 patients referred for coronary angiography. A total of 75 stents in 52 patients were assessed: 48 of 75 stents (64%) in 36 of 52 patients (69%) could be evaluated. The prevalence of in-stent restenosis by quantitative coronary angiography (QCA) in this subgroup was 23% (17/75). Eighty percent of the stents were ≤ 3.0 mm in diameter. RESULTS The overall sensitivity, specificity, positive predictive value, and negative predictive value to detect 50% in-stent stenosis visually using MDCT compared with QCA was 33.3%, 91.7%, 57.1%, and 80.5%, respectively, with an overall accuracy of 77.1% for the 48 assessable stents. The ability to evaluate stents on MDCTA varied by stent type: Thick-strut stents such as Bx Velocity were assessable in 50% of the cases; Cypher, 62.5% of the cases; and thinner-strut stents such as Taxus, 75% of the cases. We performed quantitative assessment of in-stent contrast attenuation in Hounsfield units and correlated that value with the quantitative percentage of stenosis by QCA. The correlation coefficient between the average attenuation decrease and ≥ 50% stenosis by QCA was 0.25 (p = 0.073). Quantitative assessment failed to improve the accuracy of MDCT over qualitative assessment. CONCLUSION The results of our study showed that 64-MDCT has poor ability to detect in-stent restenosis in small-diameter stents. Evaluability and negative predictive value were better in large-diameter stents. Thus, 64-MDCT may be appropriate for stent assessment in only selected patients. PMID:20028909

  8. Prolonged high-pressure is required for optimal stent deployment as assessed by optical coherence tomography.

    PubMed

    Cook, Jeffrey R; Mhatre, Ajay; Wang, Fen Wei; Uretsky, Barry F

    2014-03-01

    Optimizing stent deployment is important for both acute- and long-term outcomes. High-pressure balloon inflation is the standard for coronary stent implantation. However, there is no standardized inflation protocol. We hypothesized that prolonged high-pressure balloon inflation until stabilization of inflation pressure is superior to a rapid inflation/deflation sequence for both stent expansion and strut apposition. A high-pressure rapid inflation/deflation sequence was deployed followed by angiography to assure no residual stenosis. Optical coherence tomography (OCT) was then performed followed by prolonged inflation until balloon pressure was stabilized for 30 sec using the same balloon at the same pressure as the rapid sequence. A second OCT run was then done. Thirteen thousand nine hundred thirteen stent struts were evaluated by OCT in 12 patients undergoing successful stenting. Stent expansion improved with prolonged (206 ± 115 sec) vs. rapid (28 ± 17 sec) inflation for both minimal stent diameter (3.0 ± 0.5 vs. 2.75 ± 0.44 mm, P < 0.0001) and area (7.83 ± 2.45 vs. 6.63 ± 1.85 mm(2) , P = 0.0003). The number of malapposed struts decreased (45 ± 41 vs. 88 ± 75, P = 0.005) as did the maximal malapposed strut distance (0.31 ± 0.2 vs. 0.43 ± 0.2 mm, P = 0.0001). Factors related to strut malapposition after rapid inflation included localized asymmetry in 67%, stent underexpansion in 75%, and stent undersizing in 67%. These data demonstrate that prolonged inflation is superior to a rapid inflation/deflation technique for both stent expansion and strut apposition. We recommend for routine stent deployment a prolonged inflation protocol as described above to optimize stent deployment. Copyright © 2012 Wiley Periodicals, Inc.

  9. [Anesthetic management of tracheobronchial stent insertion in patients who underwent laser resection, balloon dilatation and tracheostomy in advance].

    PubMed

    Hirai, Akiko; Hirose, Yoshifumi; Gamoh, Masahiro; Satoh, Minako

    2005-10-01

    We report successful management of tracheobronchial stent insertion under general anesthesia. In thirty-two cases, tracheobronchial stent insertion was performed under general anesthesia. The technique for airway management was chosen depending on the type of stent or the constriction level of the airway portion. We employed tracheostomy in order to avoid repeated intubations during the insertion of Dumon or Dynamic stent. In case of severe airway stenosis, laser resection or balloon dilatation was performed before stent insertion. We had 32 successful cases in 36 trials. Four trials failed due to insufficient expansion in one, mismatches of stent angle in one and pneumomediastinum in one. There was no exacerbation of respiratory condition in failed cases. There was no case who needed percutaneous cardiopulmonary support system. We managed tracheobronchial stent insertion under general anesthesia. Both the airway expansion by laser resection or balloon dilatation before stent insertion and also the insertion of Dumon or Dynamic stent through a tracheostomy were helpful strategies. These techniques facilitated more definitive airway maintenance and stable anesthetic management.

  10. Double versus single stenting for coronary bifurcation lesions: a meta-analysis.

    PubMed

    Katritsis, Demosthenes G; Siontis, George C M; Ioannidis, John P A

    2009-10-01

    Several trials have addressed whether bifurcation lesions require stenting of both the main vessel and side branch, but uncertainty remains on the benefits of such double versus single stenting of the main vessel only. We have conducted a meta-analysis of randomized trials including patients with coronary bifurcation lesions who were randomly selected to undergo percutaneous coronary intervention by either double or single stenting. Six studies (n=1642 patients) were eligible. There was increased risk of myocardial infarction with double stenting (risk ratio, 1.78; P=0.001 by fixed effects; risk ratio, 1.49 with Bayesian meta-analysis). The summary point estimate suggested also an increased risk of stent thrombosis with double stenting, but the difference was not nominally significant given the sparse data (risk ratio, 1.85; P=0.19). No obvious difference was seen for death (risk ratio, 0.81; P=0.66) and target lesion revascularization (risk ratio, 1.09; P=0.67). Stenting of both the main vessel and side branch in bifurcation lesions may increase myocardial infarction and stent thrombosis risk compared with stenting of the main vessel only.

  11. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    PubMed

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. A randomized trial comparing primary angioplasty versus stent placement for symptomatic intracranial stenosis

    PubMed Central

    Qureshi, Adnan I; Chaudhry, Saqib A; Siddiq, Farhan; Majidi, Shahram; Rodriguez, Gustavo J; Suri, M Fareed K

    2013-01-01

    Background: Both primary angioplasty alone and angioplasty with a self-expanding stent have been compared in non-randomized concurrent clinical studies that suggest equivalent results. However, there is no randomized trial that has compared the two procedures in patients with symptomatic high grade intracranial stenosis. Objective: The primary aim of the randomized trial was to compare the clinical and angiographic efficacy of primary angioplasty and angioplasty followed by stent placement in preventing restenosis, stroke, requirement for second treatment, and death in patients with symptomatic intracranial stenosis. Methods: The study prospectively evaluated efficacy and safety of the two existing neurointerventional techniques for treatment of moderate intracranial stenosis (stenosis ≥ 50%) with documented failure of medical treatment or severe stenosis (≥70%) with or without failure of medical treatment. Results: A total of 18 patients were recruited in the study (mean age [±SD] was 64.7 ± 15.1 years); out of these, 12 were men. Of these 18, 10 were treated with primary angioplasty and 8 were treated with angioplasty followed by self-expanding stent. The technical success rates of intracranial angioplasty and stent placements defined as ability to achieve <30% residual stenosis when assessed by immediate post-procedure angiography was 5 of 10 and 5 of 8 patients, respectively. The total fluoroscopic time (mean [±SD]) was lower in patients undergoing primary angioplasty 37 [±11] min versus those undergoing angioplasty followed by self-expanding stent 42 [±15] min, P = 0.4321. The stroke and death rate within 1 month was very low in both patient groups (1 of 10 versus 0 of 8 patients). One patient randomized to stent placement continued to have recurrent ischemic symptoms requiring another angioplasty in the vertebral artery on post-procedure Day 2. Conclusions: The trial suggests that a randomized trial comparing primary angioplasty to angioplasty followed by stent placement is feasible. The immediate procedural outcomes with primary angioplasty are comparable to stent placement and warrant further studies. PMID:24358415

  13. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José-Ramón; Masotti, Mónica; Zueco, Javier; Melgares, Rafael; Mainar, Vicente; Moreno, Raul; Domínguez, Antonio; Sanchís, Juan; Bethencourt, Armando; Moreu, José; Cequier, Angel; Martí, Vicens; Otaegui, Imanol; Bastante, Teresa; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Cárdenas, Alberto; Fernández, Cristina

    2016-07-01

    Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22±0.5 versus 2.38±0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03±0.7 versus 2.36±0.6 mm, P<0.001) and diameter stenosis (23±22 versus 13±17%, P<0.001) were poorer in patients with DES-ISR. Results were consistent in the in-segment and in-lesion analyses. On multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR. Finally, at 1-year clinical follow-up (100% of patients), mortality (2.6 versus 0%, P<0.01) and need for target vessel revascularization (8 versus 2%, P=0.03) were higher in the DES-ISR group. This patient-level pooled analysis of the RIBS IV and RIBS V randomized clinical trials suggests that EES provide favorable outcomes in patients with ISR. However, the results of EES are less satisfactory in patients with DES-ISR than in those with bare-metal stent ISR. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01239953 and NCT01239940. © 2016 American Heart Association, Inc.

  14. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    PubMed

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Sirolimus versus paclitaxel coronary stents in clinical practice.

    PubMed

    Millauer, Niklas; Jüni, Peter; Hofmann, Alexandra; Wandel, Simon; Bhambhani, Anupham; Billinger, Michael; Urwyler, Niklaus; Wenaweser, Peter; Hellige, Gerrit; Räber, Lorenz; Cook, Stéphane; Vogel, Rolf; Togni, Mario; Seiler, Christian; Meier, Bernhard; Windecker, Stephan

    2011-01-01

    We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50-0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients. Copyright © 2010 Wiley-Liss, Inc.

  16. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

    PubMed Central

    Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick

    2013-01-01

    Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased mortality compared with cobalt chromium everolimus eluting stents (1.52, 1.02 to 2.22). Overall, among all stent types, the newer generation durable polymer drug eluting stents (zotarolimus eluting stent-Resolute, cobalt chromium everolimus eluting stents, and platinum chromium everolimus eluting stents) were the most efficacious (lowest target vessel revascularization rate) stents, and cobalt chromium everolimus eluting stents were the safest with significant reductions in definite stent thrombosis (rate ratio 0.35, 0.21 to 0.53), myocardial infarction (0.65, 0.55 to 0.75), and death (0.72, 0.58 to 0.90) compared with bare metal stents. Conclusions Biodegradable polymer drug eluting stents are superior to first generation durable polymer drug eluting stents but not to newer generation durable polymer stents in reducing target vessel revascularization. Newer generation durable polymer stents, and especially cobalt chromium everolimus eluting stents, have the best combination of efficacy and safety. The utility of biodegradable polymer stents in the context of excellent clinical outcomes with newer generation durable polymer stents needs to be proven. PMID:24212107

  17. Evaluation of XIENCE V everolimus-eluting and Taxus Express2 paclitaxel-eluting coronary stents in patients with jailed side branches from the SPIRIT IV trial at 2 years.

    PubMed

    Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W

    2013-06-01

    The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Intensive oral antiplatelet therapy for reduction of ischaemic events including stent thrombosis in patients with acute coronary syndromes treated with percutaneous coronary intervention and stenting in the TRITON-TIMI 38 trial: a subanalysis of a randomised trial.

    PubMed

    Wiviott, Stephen D; Braunwald, Eugene; McCabe, Carolyn H; Horvath, Ivan; Keltai, Matyas; Herrman, Jean-Paul R; Van de Werf, Frans; Downey, William E; Scirica, Benjamin M; Murphy, Sabina A; Antman, Elliott M

    2008-04-19

    Intracoronary stenting can improve procedural success and reduce restenosis compared with balloon angioplasty in patients with acute coronary syndromes, but can also increase the rate of thrombotic complications including stent thrombosis. The TRITON-TIMI 38 trial has shown that prasugrel-a novel, potent thienopyridine-can reduce ischaemic events compared with standard clopidogrel therapy. We assessed the rate, outcomes, and prevention of ischaemic events in patients treated with prasugrel or clopidogrel with stents in the TRITON-TIMI 38 study. Patients with moderate-risk to high-risk acute coronary syndromes were included in our analysis if they had received at least one coronary stent at the time of the index procedure following randomisation in TRITON-TIMI 38, and were further subdivided by type of stent received. Patients were randomly assigned in a 1 to 1 fashion to receive a loading dose of study drug (prasugrel 60 mg or clopidogrel 300 mg) as soon as possible after randomisation, followed by daily maintenance therapy (prasugrel 10 mg or clopidogrel 75 mg). All patients were to receive aspirin therapy. Treatment was to be continued for a minimum of 6 months and a maximum of 15 months. Randomisation was not stratified by stents used or stent type. The primary endpoint was the composite of cardiovascular death, non-fatal myocardial infarction, or non-fatal stroke. Stent thrombosis was assessed using Academic Research Consortium definitions, and analysis was by intention to treat. TRITON-TIMI 38 is registered with ClinicalTrials.gov, number NCT00097591. 12,844 patients received at least one coronary stent; 5743 received only drug-eluting stents, and 6461 received only bare-metal stents. Prasugrel compared with clopidogrel reduced the primary endpoint (9.7 vs 11.9%, HR 0.81, p=0.0001) in the stented cohort, in patients with only drug-eluting stents (9.0 vs 11.1%, HR 0.82, p=0.019), and in patients with only bare-metal stents (10.0 vs 12.2%, HR 0.80, p=0.003). Stent thrombosis was associated with death or myocardial infarction in 89% (186/210) of patients. Stent thrombosis was reduced with prasugrel overall (1.13 vs 2.35%, HR 0.48, p<0.0001), in patients with drug-eluting stents only (0.84 vs 2.31%, HR 0.36, p<0.0001), and in those with bare-metal stents only (1.27 vs 2.41%, HR 0.52, p=0.0009). Intensive antiplatelet therapy with prasugrel resulted in fewer ischaemic outcomes including stent thrombosis than with standard clopidogrel. These findings were statistically robust irrespective of stent type, and the data affirm the importance of intensive platelet inhibition in patients with intracoronary stents.

  19. FFR-guided multivessel stenting reduces urgent revascularization compared with infarct-related artery only stenting in ST-elevation myocardial infarction: A meta-analysis of randomized controlled trials.

    PubMed

    Gupta, Ankur; Bajaj, Navkaranbir S; Arora, Pankaj; Arora, Garima; Qamar, Arman; Bhatt, Deepak L

    2018-02-01

    Randomized controlled trials (RCTs) have shown fractional flow reserve-guided (FFR) multivessel stenting to be superior to infarct-related artery (IRA) only stenting in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. This effect was mainly driven by a reduction in overall repeat revascularization. However, the ability to assess the effect of this strategy on urgent revascularization or reinfarction was underpowered in individual trials. We searched Pubmed, EMBASE, Cochrane CENTRAL, and Web of Science for RCTs of FFR-guided multivessel stenting versus IRA-only stenting in STEMI with multivessel disease. The outcomes of interest were death, reinfarction, urgent, and non-urgent repeat revascularization. Risk ratios (RR) were pooled using the DerSimonian and Laird random-effects model. After review of 786 citations, 2 RCTs were included. The pooled results demonstrated a significant reduction in the composite of death, reinfarction, or revascularization in the FFR-guided multivessel stenting group versus IRA-only stenting group (RR [95%, Confidence Interval]: 0.49 [0.33-0.72], p<0.001). This risk reduction was driven mainly by a reduction in repeat revascularization, both urgent (0.41 [0.24-0.71], p=0.002) and non-urgent revascularization (0.31 [0.19-0.50], p<0.001). Pooled RR for reinfarction was lower in the FFR-guided strategy, but was not statistically significant (0.71[0.39-1.31], p=0.28). This systematic review and meta-analysis suggests that a strategy of FFR-guided multivessel stenting in STEMI patients reduces not only overall repeat revascularization but also urgent revascularization. The effect on reinfarction needs to be evaluated in larger trials. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  20. Twelve-month results of a prospective, multicentre trial to assess the everolimus-eluting coronary stent system (PROMUS Element): the PLATINUM PLUS all-comers randomised trial.

    PubMed

    Fajadet, Jean; Neumann, Franz-Josef; Hildick-Smith, David; Petronio, Sonia; Zaman, Azfar; Spence, Mark; Wöhrle, Jochen; Elhadad, Simon; Roberts, David; Hovasse, Thomas; Valdés, Mariano; Silber, Sigmund

    2017-01-20

    The aim of the study was to compare the safety and efficacy of the platinum-chromium-based everolimus-eluting stent (EES) with a cobalt-chromium EES. We performed a prospective, multicentre, single-blind non-inferiority all-comers study randomising patients with stable or unstable coronary artery disease (2:1) to treatment with the platinum-chromium EES (n=1,952) or the control cobalt-chromium EES (n=1,028) in Europe (PLATINUM PLUS trial). The primary endpoint was target vessel failure (TVF) at 12 months, a composite of target vessel-related cardiac death, myocardial infarction (MI), and ischaemia-driven target vessel revascularisation (TVR). Among 2,980 patients, 33% presented with acute coronary syndromes, and 48% with multivessel disease. At 12 months, the intention-to-treat analysis determined that the platinum-chromium EES was non-inferior to the cobalt-chromium EES for the primary endpoint (86 [4.6%] patients vs. 32 [3.2%], absolute difference 1.4%, 95% confidence interval [CI]: -0.1-2.9; upper limit of the one-sided 95% CI: 2.57%; non-inferiority p=0.012; superiority analysis: hazard ratio [HR] 1.44, 95% CI: 0.96-2.16, p=0.08). In the per protocol analysis, however, the primary endpoint was significantly more common in the platinum-chromium EES (HR 1.64, 95% CI: 1.05-2.55, p=0.03). There were no significant differences in the rates of cardiac death (1.1% vs. 1.0%, p=0.78), MI (1.6% vs. 0.8%, p=0.09), or ischaemia-driven TLR (2.0% vs. 1.6%, p=0.49). The rates of ARC definite or probable stent thrombosis were comparable between platforms (0.8% vs. 0.5%, p=0.44). At one year, the platinum-chromium EES satisfied the pre-specified criteria for non-inferiority relative to the control cobalt-chromium EES in this all-comers trial.

  1. Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

    PubMed Central

    Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado

    2015-01-01

    Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a low number of events. Trials had heterogeneity regarding investigation periods, baseline characteristics, and endpoint reporting, with a lack of information at long term follow-up. Direct and indirect evidence was also inconsistent for the comparison between drug eluting stents and drug coated balloons. What this study adds Compared with other currently available interventional treatments for coronary in-stent restenosis, drug coated balloons and drug eluting stents are associated with superior clinical and angiographic outcomes, with a similar comparative efficacy. Funding, competing interests, data sharing This study received no external funding. The authors declare no competing interests. No additional data available. PMID:26537292

  2. Drug-eluting stents and glycoprotein IIb/IIIa inhibitors in vessels at low anatomic risk: a retrospective analysis of previously published data from the Basel Stent Kosten Effektivitäts Trial.

    PubMed

    Jeger, Raban V; Brunner-La Rocca, Hans Peter; Hunziker, Patrick R; Tsakiris, Dimitrios A; Kaiser, Christoph A; Pfisterer, Matthias E

    2009-12-01

    Drug-eluting stents (DESs) are associated with late stent thromboses, but the exact mechanism of action is unknown. The goal of this article was to assess the clinical interaction of glycoprotein IIb/IIIa inhibitors (GPIs) with different stent and vessel types in unselected patients undergoing percutaneous coronary intervention (PCI). This was a predefined retrospective analysis of the randomized controlled Basel Stent Kosten Effektivitats Trial (BASKET), which compared DES with bare-metal stents (BMSs) in patients undergoing PCI. Patients were compared for major adverse clinical events in relation to GPI use (abciximab and tirofiban) after 18 months. In a subgroup analysis prespecified in the study protocol, specific regard was given to angiographic groups at different risk levels for late events (high-risk vessels [ie, small vessels with a diameter <3.0 mm and saphenous vein grafts], and low-risk vessels [ie, large native vessels > or =3.0 mm]). Baseline differences between patients with or without GPI use were identified and incorporated into a multivariable Cox proportional hazards regression analysis if different at a <0.05 level. A total of 826 patients (650 males, 176 females) were enrolled in BASKET; 301 (36%) received GPI therapy. Of these 301 patients, 255 (85%) received abciximab and 46 (15%) received tirofiban. After 18 months, the rate of cardiac death and nonfatal myocardial infarction was higher in patients with GPI use than in those without GPI use (35/301 [12%] vs 32/525 [6%]; P = 0.005). In patients undergoing PCI in anatomically low-risk vessels and receiving GPI therapy, there was a higher rate of cardiac death and nonfatal myocardial infarction at 18 months with a DES versus a BMS (22/151 [15%] vs 3/66 [5%]; P = 0.033). In patients undergoing PCI in anatomically low-risk vessels and without GPI therapy, there was no significant difference for cardiac death and nonfatal myocardial infarction (DES vs BMS, 11/207 [5%] vs 6/134 [4%]). In the multivariable analysis, GPI use (hazard ratio = 2.93; 95% CI, 1.53-5.63; P = 0.001) and age (hazard ratio = 1.034 per year increase; 95% CI, 1.008-1.062; P = 0.012) remained the only significant independent predictors of outcome. Interaction of stent type and GPI use was significant (P = 0.006). This retrospective analysis of the BASKET data found that GPIs and DESs used in patients with large native vessels may have an adverse interaction in terms of late stent thromboses. However, large prospective studies are needed to confirm these findings. Copyright 2009 Excerpta Medica Inc. All rights reserved.

  3. Stent placement vs. balloon angioplasty for popliteal artery treatment: two-year results of a prospective, multicenter, randomized trial.

    PubMed

    Rastan, Aljoscha; Krankenberg, Hans; Baumgartner, Iris; Blessing, Erwin; Müller-Hülsbeck, Stefan; Pilger, Ernst; Scheinert, Dierk; Lammer, Johannes; Beschorner, Ulrich; Noory, Elias; Neumann, Franz-Josef; Zeller, Thomas

    2015-02-01

    To investigate the 2-year technical and clinical results of primary nitinol stent placement in comparison with percutaneous transluminal angioplasty (PTA) in the treatment of de novo lesions of the popliteal artery. The ETAP study (Endovascular Treatment of Atherosclerotic Popliteal Artery Lesions: balloon angioplasty vs. primary stenting; www.ClinicalTrials.gov identifier NCT00712309) is a prospective, randomized trial that enrolled 246 patients (158 men; mean age 72 years) who were randomly assigned to receive a nitinol stent (n=119) or PTA (n=127) for lesions averaging 42.3 mm in length. The results of the primary study endpoint were published. Secondary outcome measures and endpoints included primary patency (freedom from duplex-detected target lesion restenosis), target lesion revascularization (TLR), secondary patency, changes in ankle-brachial index and Rutherford class, and event-free survival (freedom from target limb amputation, TLR, myocardial infarction, and death). In total, 183 patients (89 stent and 94 PTA) were available for the 2-year analysis. The primary patency rate was significantly higher in the stent group (64.2%) than in the PTA group (31.3%, p=0.0001). TLR rates were 22.4% and 59.5%, respectively (p=0.0001). When provisional stent placement in the PTA arm was not considered as TLR and loss in patency, the differences prevailed between the study groups but were not significant (64.2% vs. 56.1% for primary patency, respectively; p=0.44). A significant improvement in ABI and Rutherford category was observed at 2 years in both groups. In treatment of obstructive popliteal artery lesions, provisional stenting reveals equivalent patency in comparison to primary stenting. However, the 2-year results of this trial suggest the possibility of a shift toward higher patency rates in favor of primary stenting. © The Author(s) 2015.

  4. First Approval of Improved Medical Device Conditional on Use-Result Survey in Japan - Regulatory Review of Polymer-Free Drug-Coated BioFreedom Coronary Stent.

    PubMed

    Konishi, Akihide; Ho, Mami; Shirai, Yuko; Shirato, Haruki

    2018-05-25

    A prospective randomized clinical trial showed that the BioFreedom stent (Biosensors International), which is a polymer-free and carrier-free drug-coated stent, was significantly superior to a bare-metal stent (BMS) in patients at high bleeding risk who were receiving a 1-month course of dual antiplatelet therapy (DAPT). However, the stent thrombosis rate (2.01% for BioFreedom vs. 2.20% for BMS) was 4-6-fold higher than that of approved drug-eluting stents based on real-world data in Japan. Furthermore, the frequency of stent thrombosis at more than 1 month with the BioFreedom stent was slightly higher than that at less than 1 month. This result suggested that it would not be acceptable to stop DAPT universally at 1 month. Thus, the target patients for the BioFreedom stent are unspecified patients at high bleeding risk needing to continue DAPT for as long as necessary in Japan. Therefore, based on the pre- and post-marketing balance of medical devices regulations, regulatory approval was given for unspecified patients conditionally upon real-world data collection of 2,000 patients with a Use-Results Survey, instead of conducting additional pre-marketing clinical trial(s). The Use-Results Survey System is part of a strategy to expedite patients' access to innovative medical devices and to accelerate the development of medical devices.

  5. Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myocardial infarction: an intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial.

    PubMed

    Guo, Ning; Maehara, Akiko; Mintz, Gary S; He, Yong; Xu, Kai; Wu, Xiaofan; Lansky, Alexandra J; Witzenbichler, Bernhard; Guagliumi, Giulio; Brodie, Bruce; Kellett, Mirle A; Dressler, Ovidiu; Parise, Helen; Mehran, Roxana; Stone, Gregg W

    2010-09-14

    The incidence and mechanisms of acute and late stent malapposition after primary stent implantation in ST-segment elevation myocardial infarction remain unclear. The Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial was a dual-arm, factorial, randomized trial comparing paclitaxel-eluting stents (PES) and otherwise equivalent bare metal stents (BMS) in ST-segment elevation myocardial infarction patients. The intravascular ultrasound substudy enrolled 241 patients with 263 native coronary lesions (201 PES, 62 BMS) with baseline and 13-month follow-up imaging. Postintervention acute stent malapposition (ASM) occurred in 34.3% PES- and 40.3% BMS-treated lesions. Of these, 39.1% PES- and 40.0% BMS-treated lesions resolved at follow-up, especially within the stent body (66.7%); complete resolution was accompanied by a reduction in external elastic membrane area. An ASM area >1.2 mm(2) best separated persistent from resolved ASM. At follow-up, a higher frequency of late stent malapposition was detected in PES-treated lesions (46.8%) mainly because of more late acquired stent malapposition (30.8%) compared with BMS-treated lesions. Late acquired stent malapposition area correlated to the decrease of peri-stent plaque in the subset of lesions without positive remodeling and only to change in external elastic membrane in the group with positive remodeling. Independent predictors of late acquired stent malapposition were plaque/thrombus protrusion (odds ratio, 5.60; 95% confidence interval [CI], 2.32 to 13.54) and PES use (odds ratio, 6.32; 95% CI, 2.15 to 18.62). The incidence of ASM was similar in PES- and BMS-treated lesions, but late acquired stent malapposition was more common in PES-treated lesions. The reason for resolved ASM was negative remodeling, with larger ASM areas separating persistent from resolved ASM. Late acquired stent malapposition was due mainly to positive remodeling and plaque/thrombus resolution. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00433966.

  6. Titanium-nitride-oxide-coated coronary stents: insights from the available evidence.

    PubMed

    Karjalainen, Pasi P; Nammas, Wail

    2017-06-01

    Coating of stent surface with a biocompatible material is suggested to improve stent safety profile. A proprietary process was developed to coat titanium-nitride-oxide on the stent surface, based on plasma technology that uses the nano-synthesis of gas and metal. Preclinical in vitro and in vivo investigation confirmed blood compatibility of titanium (nitride-) oxide films. Titanium-nitride-oxide-coated stents demonstrated a better angiographic outcome, compared with bare-metal stents at mid-term follow-up; however, they failed to achieve non-inferiority for angiographic outcome versus second-generation drug-eluting stents. Observational studies showed adequate clinical outcome at mid-term follow-up. Non-randomized studies showed an outcome of titanium-nitride-oxide-coated stents comparable to - or better than - first-generation drug-eluting stents at long-term follow-up. Two randomized controlled trials demonstrated comparable efficacy outcome, and a better safety outcome of titanium-nitride-oxide-coated stents versus drug-eluting stents at long-term follow-up. Evaluation by optical coherence tomography at mid-term follow-up revealed better neointimal strut coverage associated with titanium-nitride-oxide-coated stents versus drug-eluting stents; yet, neointimal hyperplasia thickness was greater. Key messages Stents coated with titanium-nitride-oxide demonstrated biocompatibility in preclinical studies: they inhibit platelet and fibrin deposition, and reduce neointimal growth. In observational and non-randomized studies, titanium-nitride-oxide-coated stents were associated with adequate safety and efficacy outcome. In randomized trials of patients with acute coronary syndrome, titanium-nitride-oxide-coated stents were associated with a better safety outcome, compared with drug-eluting stents; efficacy outcome was comparable.

  7. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    PubMed

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare-metal stents at 2-year follow-up. In randomised studies completed to date, CoCr-EES has the lowest rate of stent thrombosis within 2 years of implantation. The finding that CoCr-EES also reduced stent thrombosis compared with bare-metal stents, if confirmed in future randomised trials, represents a paradigm shift. The Cardiovascular Research Foundation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials.

    PubMed

    Kheiri, Babikir; Osman, Mohammed; Abdalla, Ahmed; Ahmed, Sahar; Bachuwa, Ghassan; Hassan, Mustafa

    2018-05-11

    The use of drug-eluting stents (DES) vs bare-metal stents (BMS) in saphenous vein graft (SVG) lesions remains controversial. We conducted a meta-analysis of all randomized clinical trials comparing the outcomes of DES with BMS in SVG percutaneous coronary interventions. A search of PubMed, Embase, the Cochrane Register of Controlled Trials, and Clinicaltrials.gov was performed for all randomized clinical trials. We evaluated the short- and long-term clinical outcomes of the following: all-cause mortality, major adverse cardiovascular events (MACE), definite/probable stent thrombosis, target lesion revascularization (TLR), and target-vessel revascularization (TVR). From a total of 1582 patients in 6 randomized clinical trials, 797 had DES and 785 had BMS. Patients with DES had lower short-term MACE, TLR, and TVR in comparison with BMS (odds ratio [OR]: 0.56, 95% confidence interval [CI]: 0.35-0.91, P = 0.02; OR: 0.43, 95% CI: 0.19-0.99, P = 0.05; and OR: 0.45, 95% CI: 0.22-0.95, P = 0.04, respectively). However, there were no different outcomes for all-cause mortality (P = 0.63) or stent thrombosis (P = 0.21). With long-term follow-up, there were no significant reductions of MACE (P = 0.20), TLR (P = 0.57), TVR (P = 0.07), all-cause mortality (P = 0.29), and stent thrombosis (P = 0.76). The use of DES in SVG lesions was associated with lower short-term MACE, TLR, and TVR in comparison with BMS. However, there were no significant differences with long-term follow-up. © 2018 Wiley Periodicals, Inc.

  9. A randomised comparison of Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion: rationale and design of the CIT-RESOLVE trial.

    PubMed

    Zhang, Dong; Yin, Dong; Song, Chenxi; Zhu, Chengang; Kirtane, Ajay J; Xu, Bo; Dou, Kefei

    2017-06-12

    The intentional strategy (aggressive side branch (SB) protection strategy: elective two-stent strategy or jailed balloon technique) is thought to be associated with lower SB occlusion rate than conventional strategy (provisional two-stent strategy or jailed wire technique). However, most previous studies showed comparable outcomes between the two strategies, probably due to no risk classification of SB occlusion when enrolling patients. There is still no randomised trial compared the intentional and conventional strategy when treating bifurcation lesions with high risk of SB occlusion. We aim to investigate if intentional strategy is associated with significant reduction of SB occlusion rate compared with conventional strategy in high-risk patients. The Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion (CIT-RESOLVE) is a prospective, randomised, single-blind, multicentre clinical trial comparing the rate of SB occlusion between the intentional strategy group and the conventional strategy group (positive control group) in a consecutive cohort of patients with high risk of side branch occlusion defined by V-RESOLVE score, which is a validated angiographic scoring system to evaluate the risk of SB occlusion in bifurcation intervention and used as one of the inclusion criteria to select patients with high SB occlusion risk (V-RESOLVE score ≥12). A total of 21 hospitals from 10 provinces in China participated in the present study. 566 patients meeting all inclusion/exclusion criteria are randomised to either intentional strategy group or conventional strategy group. The primary endpoint is SB occlusion (defined as any decrease in thrombolysis in myocardial infarction flow grade or absence of flow in SB after main vessel stenting). All patients are followed up for 12-month postdischarge. The protocol has been approved by all local ethics committee. The ethics committee have approved the study protocol, evaluated the risk to benefit ratio, allowed operators with a minimum annual volume of 200 cases to participate in the percutaneous coronary intervention procedure and permitted them to perform both conventional and intentional strategies. Written informed consent would be acquired from all participants. The findings of the trial will be shared by the participant hospitals and disseminated through peer-reviewed journals. NCT02644434; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p < 0.01). Three-year clinical follow-up was obtained in all enrolled patients (100%). The combined clinical outcome measure of cardiac death, myocardial infarction and target lesion revascularization was significantly reduced in the EES arm (19 [12.3%] vs. 31 [20.1%]; p = 0.04; hazard ratio: 0.57 [95% confidence interval: 0.34 to 0.96]), driven by a lower need for target lesion revascularization (11 [7.1%] vs. 24 [15.6%]; p = 0.015; hazard ratio: 0.43 [95% confidence interval: 0.21 to 0.87]). The need for "late" (>1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  11. Sirolimus- versus paclitaxel-eluting stents in patients with stenosis in a native coronary artery.

    PubMed

    Doggrell, Sheila A

    2004-06-01

    With stenting, restenosis occurs in approximately 25% of patients and the incidence is even higher in patients with diabetes, small coronary vessels and long lesions. The sirolimus-eluting balloon-expandable stent in the treatment of patients with de novo native coronary-artery lesions (SIRIUS) trial, enrolled patients with more challenging conditions, including a higher frequency of diabetes, more complex lesion morphology and longer lesions and showed benefits in all groups. After 240 days, the frequency of stenosis of at least 50% of the luminal diameter was 3.2 and 35.4% in the sirolimus and standard stents groups, respectively. The TAXUS-IV trial was the first large-scale trial on the safety and efficacy of paclitaxel-eluting stents in a broad population of patients and lesions, and established the safety and effectiveness of this agent. After 9 months, there was a mean stenosis of 17% in the paclitaxel group compared to 37% of patients treated with a bare stent. Thus, the local delivery of potent cell cycle inhibitors (sirolimus, paclitaxel) from stents being used for revascularisation dramatically decreases the incidence of restenosis in the populations of patients studied so far and represents a major advancement in the treatment of coronary artery disease.

  12. Safety of 6-month duration of dual antiplatelet therapy after percutaneous coronary intervention in patients with acute coronary syndromes: Rationale and design of the Smart Angioplasty Research Team-safety of 6-month duration of Dual Antiplatelet Therapy after percutaneous coronary intervention in patients with acute coronary syndromes (SMART-DATE) prospective multicenter randomized trial.

    PubMed

    Lee, Joo Myung; Cho, Deok-Kyu; Hahn, Joo-Yong; Song, Young Bin; Park, Taek Kyu; Oh, Ju-Hyeon; Lee, Jin Bae; Doh, Joon-Hyung; Kim, Sang-Hyun; Yang, Jeong Hoon; Choi, Jin-Ho; Choi, Seung-Hyuck; Lee, Sang Hoon; Gwon, Hyeon-Cheol

    2016-12-01

    Dual antiplatelet therapy (DAPT) is a fundamental treatment that optimizes clinical outcomes after percutaneous coronary intervention, especially in patients with acute coronary syndrome (ACS). Although current international guidelines recommend DAPT for at least 12 months after implantation of a drug-eluting stent in patients with ACS, these recommendations are not based on randomized controlled trials dedicated to ACS population. The SMART-DATE trial is a prospective, multicenter, randomized, and open-label study to demonstrate the noninferiority of 6-month DAPT compared with 12 months or longer DAPT in patients with ACS undergoing percutaneous coronary intervention. A total of 2,700 patients will undergo prospective, random assignment to either of the DAPT duration groups. To minimize the bias from different stent devices, the type of stents will be randomly assigned (everolimus-eluting stents, zotarolimus-eluting stents, or biolimus A9-eluting stents). The primary end point is a composite of all-cause death, myocardial infarction, and cerebrovascular events at 18 months after the index procedure. The major secondary end points are definite/probable stent thrombosis defined by the Academic Research Consortium and bleeding defined by Bleeding Academic Research Consortium type 2-5. The SMART-DATE randomized trial is the first study exploring the safety of 6-month DAPT compared with conventional 12-month or longer DAPT dedicated to patients with ACS after second-generation drug-eluting stent implantation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    PubMed

    Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L; Bonati, Leo H; van der Worp, H Bart; de Borst, Gert J; Lo, T Hauw; Gaines, Peter; Dorman, Paul J; Macdonald, Sumaira; Lyrer, Philippe A; Hendriks, Johanna M; McCollum, Charles; Nederkoorn, Paul J; Brown, Martin M

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4.0%) events of disabling stroke or death in the stenting group compared with 27 (3.2%) events in the endarterectomy group (hazard ratio [HR] 1.28, 95% CI 0.77-2.11). The incidence of stroke, death, or procedural myocardial infarction was 8.5% in the stenting group compared with 5.2% in the endarterectomy group (72 vs 44 events; HR 1.69, 1.16-2.45, p=0.006). Risks of any stroke (65 vs 35 events; HR 1.92, 1.27-2.89) and all-cause death (19 vs seven events; HR 2.76, 1.16-6.56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0.0197). Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery. Medical Research Council, the Stroke Association, Sanofi-Synthélabo, European Union. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. Efficacy and safety of a biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in treating de novo coronary artery disease: A pooled analysis of the CREDIT II and CREDIT III trials.

    PubMed

    Wang, Geng; Wang, Heyang; Xu, Bo; Yang, Yuejin; Yang, Zhiming; Li, Hui; Zhang, Zheng; Wang, Haichang; Yang, Lixia; Han, Yaling

    2017-03-01

    The safety and efficacy of the second-generation biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in daily clinical practice remains unknown. Additionally, to meet the China Food and Drug Administration requirements, we conducted an objective performance criterion study from the CREDIT II and CREDIT III trials. CREDIT II was a randomized trial comparing the EXCEL2 versus EXCEL stent in patients with up to 2 de novo coronary lesions. CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCEL2 in broad types of de novo coronary artery lesions. This pooled analysis included patients in the CREDIT III and EXCEL2 arm of the CREDIT II trial. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinical indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. A total of 833 patients were included, consisting of 625 in the CREDIT III trial and 208 in the EXCEL2 arm of the CREDIT II trial. Twelve-month TLF occurred in 6.1% patients, cardiac death in 0.4%, TV-MI in 5%, and CI-TLR in 1.1%. Additionally, 64 (7.7%) PoCE and 3 probable late stent thromboses (0.4%) were recorded. EXCEL2 stent met the objective performance criterion on efficacy and safety with a low level of 12-month TLF as well as stent thrombosis when treating patients with de novo coronary lesions. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. 30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial.

    PubMed

    Ringleb, P A; Allenberg, J; Brückmann, H; Eckstein, H-H; Fraedrich, G; Hartmann, M; Hennerici, M; Jansen, O; Klein, G; Kunze, A; Marx, P; Niederkorn, K; Schmiedt, W; Solymosi, L; Stingele, R; Zeumer, H; Hacke, W

    2006-10-07

    Carotid endarterectomy is effective in stroke prevention for patients with severe symptomatic carotid-artery stenosis, and carotid-artery stenting has been widely used as alternative treatment. Since equivalence or superiority has not been convincingly shown for either treatment, we aimed to compare the two. 1200 patients with symptomatic carotid-artery stenosis were randomly assigned within 180 days of transient ischaemic attack or moderate stroke (modified Rankin scale score of < or =3) carotid-artery stenting (n=605) or carotid endarterectomy (n=595). The primary endpoint of this hospital-based study was ipsilateral ischaemic stroke or death from time of randomisation to 30 days after the procedure. The non-inferiority margin was defined as less than 2.5% on the basis of an expected event rate of 5%. Analyses were on an intention-to-treat basis. This trial is registered at Current Controlled Trials with the international standard randomised controlled trial number ISRCTN57874028. 1183 patients were included in the analysis. The rate of death or ipsilateral ischaemic stroke from randomisation to 30 days after the procedure was 6.84% with carotid-artery stenting and 6.34% with carotid endarterectomy (absolute difference 0.51%, 90% CI -1.89% to 2.91%). The one-sided p value for non-inferiority is 0.09. SPACE failed to prove non-inferiority of carotid-artery stenting compared with carotid endarterectomy for the periprocedural complication rate. The results of this trial do not justify the widespread use in the short-term of carotid-artery stenting for treatment of carotid-artery stenoses. Results at 6-24 months are awaited.

  16. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.

    PubMed

    Serruys, Patrick W; Farooq, Vasim; Kalesan, Bindu; de Vries, Ton; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Wijns, William; Morice, Marie Claude; Di Mario, Carlo; Corti, Roberto; Antoni, Diethmar; Sohn, Hae Y; Eerdmans, Pedro; Rademaker-Havinga, Tessa; van Es, Gerrit-Anne; Meier, Bernhard; Jüni, Peter; Windecker, Stephan

    2013-08-01

    This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Wing-shaped plastic stents vs. self-expandable metal stents for palliative drainage of malignant distal biliary obstruction: a randomized multicenter study.

    PubMed

    Schmidt, Arthur; Riecken, Bettina; Rische, Susanne; Klinger, Christoph; Jakobs, Ralf; Bechtler, Matthias; Kähler, Georg; Dormann, Arno; Caca, Karel

    2015-05-01

    Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS.  Stent failure occurred in 10/16 patients (62.5 %) in the winged-stent group vs. 4/18 patients (22.2 %) in the SEMS group (P = 0.034). The median time to stent failure was 51 days (range 2 - 92 days) for the winged stent and 80 days (range 28 - 266 days) for the SEMS (P = 0.002). Early stent failure (< 8 weeks after placement) occurred in 8 patients (50 %) vs. 2 patients (11.1 %), respectively (P = 0.022). After obtaining the results from this interim analysis, the study was discontinued because of safety concerns. The frequency of stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction. Study registration ClinicalTrials.gov (NCT01063634). © Georg Thieme Verlag KG Stuttgart · New York.

  18. Very late outcomes of drug-eluting stents coated with biodegradable polymers: insights from the 5-year follow-up of the randomized PAINT trial

    PubMed Central

    Marchini, Julio F.; Gomes, Wilton F.; Moulin, Bruno; Perin, Marco A.; Oliveira, Ludmilla A.R.R.; Arruda, J. Airton; Lima, Valter C.; Lima, Antonio A.G.; Caramori, Paulo R.A.; Medeiros, Cesar R.; Barbosa, Mauricio R.; Brito, Fabio S.; Ribeiro, Expedito E.

    2014-01-01

    Background Few studies have examined the very long-term outcomes after implantation of drug-eluting stents (DES) coated with biodegradable polymers (BP). This report presents the 5-year clinical follow-up of patients treated with BP-DES in the randomized PAINT trial. Methods The PAINT study is a prospective, multicenter randomized controlled trial that allocated 274 patients for treatment with two BP-DES formulations [paclitaxel-eluting stents (PES) or sirolimus-eluting stents (SES)] or bare metal stents (BMS) in a 1:2:2 ratio, respectively. The primary end-point of this sub-study was defined as the composite of the major cardiac adverse events (MACE) cardiac death, myocardial infarction (MI) or ischemia-driven target vessel revascularization (TVR) at 5 years. Results The 5-year MACE rates were different among the groups: 35.3%, 22.5% and 16.9% for BMS, PES and SES, respectively (P<0.05 for both DES vs. bare stent comparisons). The primary end-point was mainly driven by TVR: 31.8%, 14.1% and 12.2% for bare stents, PES and SES, respectively (P<0.05 for both DES vs. bare stent comparisons). The incidence of stent thrombosis (ST) was null for BMS during the entire follow-up. There was no definite or probable ST in the SES group after the second year, while one patient (1.0%) presented with a definite ST episode in the PES group between 4 and 5 years. Conclusions The tested biodegradable-polymer coated stents releasing either paclitaxel or sirolimus, compared with same bare metal platform, sustained their effectiveness in reducing combined major adverse cardiac events and re-intervention without an increase in ST during 5 years of follow-up. PMID:25610805

  19. Wire-Interwoven Nitinol Stent Outcome in the Superficial Femoral and Proximal Popliteal Arteries: Twelve-Month Results of the SUPERB Trial.

    PubMed

    Garcia, Lawrence; Jaff, Michael R; Metzger, Christopher; Sedillo, Gino; Pershad, Ashish; Zidar, Frank; Patlola, Raghotham; Wilkins, Robert G; Espinoza, Andrey; Iskander, Ayman; Khammar, George S; Khatib, Yazan; Beasley, Robert; Makam, Satyaprakash; Kovach, Richard; Kamat, Suraj; Leon, Luis R; Eaves, William Britton; Popma, Jeffrey J; Mauri, Laura; Donohoe, Dennis; Base, Carol C; Rosenfield, Kenneth

    2015-05-01

    Stent-based therapy in the superficial femoral and popliteal arteries in patients with peripheral artery disease is compromised by restenosis and risk of stent fracture or distortion. A novel self-expanding nitinol stent was developed that incorporates an interwoven-wire design (Supera stent, IDEV Technologies, Inc, Webster, TX) to confer greater radial strength, flexibility, and fracture resistance. This prospective, multicenter, investigational device exemption, single-arm trial enrolled 264 patients with symptomatic peripheral artery disease undergoing percutaneous treatment of de novo or restenotic lesions of the superficial femoral or proximal popliteal (femoropopliteal) artery. Freedom from death, target lesion revascularization, or any amputation of the index limb at 30 days (+ 7 days) postprocedure was achieved in 99.2% (258/260) of patients (P < 0.001). Primary patency at 12 months (360 ± 30 days) was achieved in 78.9% (180/228) of the population (P < 0.001). Primary patency by Kaplan-Meier analysis at 12 months (360 days) was 86.3%. No stent fracture was observed by independent core laboratory analysis in the 243 stents (228 patients) evaluated at 12 months. Clinical assessment at 12 months demonstrated improvement by at least 1 Rutherford-Becker category in 88.7% of patients. The SUPERB Trial, an investigational device exemption study using an interwoven nitinol wire stent in the femoropopliteal artery, achieved the efficacy and safety performance goals predesignated by the Food and Drug Administration. On the basis of the high primary patency rate, absence of stent fracture, and significant improvements in functional and quality-of-life measures, the Supera stent provides safe and effective treatment of femoropopliteal lesions in symptomatic patients with peripheral artery disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00933270. © 2015 American Heart Association, Inc.

  20. Treatment protocol based on assessment of clot quality during endovascular thrombectomy for acute ischemic stroke using the Trevo stent retriever

    PubMed Central

    Ishikawa, Kojiro; Ohshima, Tomotaka; Nishihori, Masahiro; Imai, Tasuku; Goto, Shunsaku; Yamamoto, Taiki; Nishizawa, Toshihisa; Shimato, Shinji; Kato, Kyozo

    2016-01-01

    ABSTRACT The optional endovascular approach for acute ischemic stroke is unclear. The Trevo stent retriever can be used as first-line treatment for fast mechanical recanalization. The authors developed a treatment protocol for acute ischemic stroke based on the assessment of clot quality during clot removal with the Trevo. This prospective single-center study included all patients admitted for acute ischemic stroke between July 2014 and February 2015, who underwent emergency endovascular treatment. According to the protocol, the Trevo was used for first-line treatment. Immediately after the Trevo was deployed, the stent delivery wire was pushed to open the stent by force (ACAPT technique). Clot quality was assessed on the basis of the perfusion status after deployment of the Trevo; continued occlusion or immediate reopening either reoccluded or maintained after the stent retriever had been in place for 5 min. If there was no obvious clot removal after the first pass with the Trevo, according to the quality of the clot, either a second pass was performed or another endovascular device was selected. Twelve consecutive patients with acute major cerebral artery occlusion were analyzed. Thrombolysis in cerebral infarction score 2b and 3 was achieved in 11 patients (91.7%) and 9 (75%) had a good clinical outcome after 90 days based on a modified Rankin scale score ≤ 2. Symptomatic intracranial hemorrhage occurred in 1 patient (8.3%). The overall mortality rate was 8.3%. Endovascular thrombectomy using the Trevo stent retriever for first-line treatment is feasible and effective. PMID:27578909

  1. Nitinol versus steel partially covered self-expandable metal stent for malignant distal biliary obstruction: a randomized trial.

    PubMed

    Soderlund, Claes; Linder, Stefan; Bergenzaun, Per E; Grape, Tomas; Hakansson, Hans-Olof; Kilander, Anders; Lindell, Gert; Ljungman, Martin; Ohlin, Bo; Nielsen, Jorgen; Rudberg, Claes; Stotzer, Per-Ove; Svartholm, Erik; Toth, Ervin; Frozanpor, Farshad

    2014-11-01

    Covered nitinol alloy self-expandable metal stents (SEMSs) have been developed to overcome the shortcomings of steel SEMS in patients with malignant biliary obstruction. In a randomized, multicenter trial, we compared stent patency, patient survival, and adverse events in patients with partly covered stents made from steel or nitinol. A total of 400 patients with unresectable distal malignant biliary obstruction were randomized at endoscopic retrograde cholangiopancreatography (ERCP) to insertion of a steel or nitinol partially covered SEMS, with 200 patients in each group. The primary outcome was confirmed stent failure during 300 days of follow-up.  At 300 days, the proportion of patients with patent stents was 77 % in the steel group, compared with 89 % in the nitinol group (P = 0.01). Confirmed stent failure occurred more often in the steel SEMS group compared with the nitinol SEMS group, in 30 versus 14 patients (P = 0.02). Stent migration occurred in 13 patients in the steel group and in 3 patients in the nitinol group (P = 0.01). Median patient survival (secondary outcome) was 137 days and 120 days in the steel SEMS and nitinol SEMS groups, respectively (P = 0.59). The nitinol SEMS showed longer patency time, and the nitinol group had fewer patients with stent failure, compared with the steel SEMS group. We could not detect any differences between the two groups regarding survival time, and regarding adverse event rate.Clinical trial registration : NCT 00980889. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Automatic stent strut detection in intravascular OCT images using image processing and classification technique

    NASA Astrophysics Data System (ADS)

    Lu, Hong; Gargesha, Madhusudhana; Wang, Zhao; Chamie, Daniel; Attizani, Guilherme F.; Kanaya, Tomoaki; Ray, Soumya; Costa, Marco A.; Rollins, Andrew M.; Bezerra, Hiram G.; Wilson, David L.

    2013-02-01

    Intravascular OCT (iOCT) is an imaging modality with ideal resolution and contrast to provide accurate in vivo assessments of tissue healing following stent implantation. Our Cardiovascular Imaging Core Laboratory has served >20 international stent clinical trials with >2000 stents analyzed. Each stent requires 6-16hrs of manual analysis time and we are developing highly automated software to reduce this extreme effort. Using classification technique, physically meaningful image features, forward feature selection to limit overtraining, and leave-one-stent-out cross validation, we detected stent struts. To determine tissue coverage areas, we estimated stent "contours" by fitting detected struts and interpolation points from linearly interpolated tissue depths to a periodic cubic spline. Tissue coverage area was obtained by subtracting lumen area from the stent area. Detection was compared against manual analysis of 40 pullbacks. We obtained recall = 90+/-3% and precision = 89+/-6%. When taking struts deemed not bright enough for manual analysis into consideration, precision improved to 94+/-6%. This approached inter-observer variability (recall = 93%, precision = 96%). Differences in stent and tissue coverage areas are 0.12 +/- 0.41 mm2 and 0.09 +/- 0.42 mm2, respectively. We are developing software which will enable visualization, review, and editing of automated results, so as to provide a comprehensive stent analysis package. This should enable better and cheaper stent clinical trials, so that manufacturers can optimize the myriad of parameters (drug, coverage, bioresorbable versus metal, etc.) for stent design.

  3. Re-examining minimal luminal diameter relocation and quantitative coronary angiography--intravascular ultrasound correlations in stented saphenous vein grafts: methodological insights from the randomised RRISC trial.

    PubMed

    Semeraro, Oscar; Agostoni, Pierfrancesco; Verheye, Stefan; Van Langenhove, Glenn; Van den Heuvel, Paul; Convens, Carl; Van den Branden, Frank; Bruining, Nico; Vermeersch, Paul

    2009-03-01

    Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. Using quantitative coronary angiography (QCA) data (49 bare metal stent and 44 sirolimus-eluting stent lesions) and intravascular ultrasound (IVUS) data (39 bare metal stent and 34 sirolimus-eluting stent lesions) from the randomised Reduction of Restenosis In Saphenous vein grafts with Cypher stent (RRISC) trial, we analysed the "relocation phenomenon" of QCA-based in-stent minimal luminal diameter (MLD) between post-procedure and follow-up and we correlated QCA-based and IVUS-based restenotic parameters in stented saphenous vein grafts. We expected the presence of MLD relocation for low late loss values, as MLD can "migrate" along the stent if minimal re-narrowing occurs, while we anticipated follow-up MLD to be located close to post-procedural MLD position for higher late loss. QCA-based MLD relocation occurred frequently: the site of MLD shifted from post-procedure to follow-up an "absolute" distance of 5.8 mm [2.5-10.2] and a "relative" value of 29% [10-46]. MLD relocation failed to correlate with in-stent late loss (rho = 0.14 for "absolute" MLD relocation [p = 0.17], and rho=0.03 for "relative" relocation [p = 0.811). Follow-up QCA-based and IVUS-based MLD values well correlated in the overall population (rho = 0.76, p < 0.001), but QCA underestimated MLD on average 0.55 +/- 0.49 mm, and this was mainly evident for lower MLD values. Conversely, the location of QCA-based MLD failed to correlate with the location of IVUS-based MLD (rho = 0.01 for "absolute" values--in mm [p = 0.911, rho = 0.19 for "relative" values--in % [p = 0.111). Overall, the ability of late loss to "predict" IVUS parameters of restenosis (maximum neointimal hyperplasia diameter, neointimal hyperplasia index and maximum neointimal hyperplasia area) was moderate (rho between 0.46 and 0.54 for the 3 IVUS parameters). These findings suggest the need for a critical re-evaluation of angiographic parameters (such as late loss) as endpoints for drug-eluting stent trials and the use of more precise techniques to describe accurately and properly the restenotic process.

  4. Role of Esophageal Metal Stents Placement and Combination Therapy in Inoperable Esophageal Carcinoma: A Systematic Review and Meta-analysis.

    PubMed

    Lai, Andrew; Lipka, Seth; Kumar, Ambuj; Sethi, Sajiv; Bromberg, David; Li, Nanxing; Shen, Huafeng; Stefaniwsky, Lilia; Brady, Patrick

    2018-04-01

    More than 50% of patients with esophageal cancer already have inoperable disease at the time of diagnosis. Controversy surrounds the outcomes of patients with advanced esophageal cancer who receive palliative care by either stent alone or stent plus an additional modality. We set out to perform a systematic review and meta-analysis of studies assessing the use of metal stents as treatment options for symptomatic improvement, survival, and adverse events. We searched Embase, MEDLINE, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception until January 14, 2016, as well as other databases for randomized controlled trials (RCTs) comparing esophageal stent versus either esophageal stent plus brachytherapy, radiotherapy, or chemotherapy. For quality assurance purposes throughout the systematic review, multiple independent extractions were performed, and the process was executed as per the standards of the Cochrane collaboration. Primary outcomes were mean change in dysphagia score, overall survival, and quality of life. Secondary outcomes were adverse events including fever, severe pain, aspiration, fistula, stent migration, perforation, and restenosis. Eight RCTs enrolling 732 patients were included with three distinct comparisons: stents combination therapy vs stents alone (5 studies, n = 417), stents alone versus brachytherapy alone (2 studies, n = 274), and stents + brachytherapy vs brachytherapy alone (1 study, n = 41). Stents combination therapy was defined as stents plus radiotherapy, chemotherapy, or both. Mean change in dysphagia scores favored stents combination therapy versus stents alone, and the effect was seen in patients surviving longer than 3 months. Stents combination therapy was also associated with a more favorable overall survival. The risks of stent migration, aspiration pneumonia, and restenosis were lower in the stents combination group compared to stents alone, while the risks of severe pain, hemorrhage, and fistula formation were higher. Changes in dysphagia scores and overall survival did not differ significantly in the brachytherapy-alone vs stents-alone comparison. The risk of fistula formation and hemorrhage were higher in the stents-alone group, while the risk of perforation was lower, compared to brachytherapy alone. Quality of life improvements were seen in all treatment groups, but were not pooled in analysis due to differing methods of measurement. While there appears to be no immediate short-term differences, those who live longer than 3 months experience a significant improvement in dysphagia score using a stents combination therapy approach vs stents alone. The combination therapy significantly improves the overall survival as well as showed improvements in quality of life scores. Larger randomized controlled trials are needed to assess improvements in dysphagia score, overall survival, quality of life, and adverse events.

  5. Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials).

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; Masotti, Mónica; López-Minguez, José R; Iñiguez, Andrés; Zueco, Javier; Velazquez, Maite; Cequier, Angel; Lázaro-García, Rosa; Martí, Vicens; Moris, César; Urbano-Carrillo, Cristobal; Bastante, Teresa; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-02-15

    Treatment of patients with in-stent restenosis (ISR) remains a challenge. This study sought to compare the efficacy of everolimus-eluting stents (EESs) and drug-eluting balloons (DEBs) with paclitaxel in patients with ISR. A pooled analysis of the Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS IV) and Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS V) randomized trials was performed using patient-level data. In both trials, EESs were compared with DEBs in patients with ISR (RIBS V included 189 patients with bare-metal ISR; RIBS IV included 309 patients with drug-eluting ISR). Inclusion and exclusion criteria were identical in both trials. A total of 249 patients were allocated to EES and 249 to DEB. Clinical follow-up at 1 year was obtained in all (100%) patients and late angiography (median 249 days) in 91% of eligible patients. Compared with patients treated with DEBs, patients treated with EESs obtained better short-term results (postprocedural minimal lumen diameter 2.28 ± 0.5 vs 2.12 ± 0.4 mm, p <0.0001). At follow-up, patients treated with EESs had larger in-segment minimal lumen diameter (primary end point 2.16 ± 0.7 vs 1.88 ± 0.6 mm, p <0.0001; absolute mean difference 0.28 mm; 95% confidence interval [CI] 0.16 to 0.40) and net lumen gain (1.33 ± 0.6 vs 1.00 ± 0.7 mm, p <0.0001) and had lower %diameter stenosis (19 ± 21% vs 28 ± 22%, p <0.0001) and binary restenosis rate (8.7% vs 15.7%, p = 0.02). Consistent results were observed in the in-lesion analysis. No interactions were found between the underlying stent type and treatment effects. At 1-year clinical follow-up, the composite of cardiac death, myocardial infarction, and target vessel revascularization was significantly reduced in the EES arm (8.8% vs 14.5%, p = 0.03; hazard ratio 0.59, 95% CI 0.31 to 0.94) mainly driven by a lower need for target vessel revascularization (6% vs 12.4%, p = 0.01, hazard ratio 0.46, 95% CI 0.25 to 0.86). This pooled analysis of the RIBS IV and RIBS V randomized trials demonstrates the superiority of EES over DEB in the treatment of patients with ISR. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. China Angioplasty and Stenting for Symptomatic Intracranial Severe Stenosis (CASSISS): A new, prospective, multicenter, randomized controlled trial in China

    PubMed Central

    Gao, Peng; Zhao, Zhenwei; Wang, Daming; Wu, Jian; Cai, Yiling; Li, Tianxiao; Wu, Wei; Shi, Huaizhang; He, Weiwen; Zhu, Fengshui; Ling, Feng

    2015-01-01

    Background Patients with symptomatic stenosis of intradural arteries are at high risk for subsequent stroke. Since the SAMMPRIS trial, stenting is no longer recommended as primary treatment; however, the results of this trial, its inclusion criteria and its center selection received significant criticism and did not appear to reflect our experience regarding natural history nor treatment complications rate. As intracranial atherosclerosis (ICAS) is the most common cause for stroke in Asian countries, we are hereby proposing a refined prospective, randomized, multicenter study in an Asian population with strictly defined patient and participating center inclusion criteria. Methods The China Angioplasty and Stenting for Symptomatic Intracranial Severe Stenosis (CASSISS) trial is an ongoing, government-funded, prospective, multicenter, randomized trial. It recruits patients with recent TIA or stroke caused by 70%–99% stenosis of a major intracranial artery. Patients with previous stroke related to perforator ischemia will not be included. Only high-volume centers with a proven track record will enroll patients as determined by a lead-in phase. Patients will be randomized (1:1) to best medical therapy alone or medical therapy plus stenting. Primary endpoints are any stroke or death within 30 days after enrollment or after any revascularization procedure of the qualifying lesion during follow-up, or stroke in the territory of the symptomatic intracranial artery beyond 30 days. The CASSISS trial will be conducted in eight sites in China with core imaging lab review at a North American site and aims to have a sample size of 380 participants (stenting, 190; medical therapy, 190). Recruitment is expected to be finished by December 2016. Patients will be followed for at least three years. The trial is scheduled to complete in 2019. Conclusion In the proposed trial, certain shortcomings of SAMMPRIS including patient and participating center selection will be addressed. The present manuscript outlines the rationale and design of the study. We estimate that this trial will allow for a critical reappraisal of the role of intracranial stenting for selected patients in high-volume centers. PMID:25934656

  8. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    PubMed Central

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. Conclusion Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment. PMID:24958153

  9. Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

    PubMed

    Seth, Ashok; Gupta, Sajal; Pratap Singh, Vivudh; Kumar, Vijay

    2017-09-01

    Final stent dimensions remain an important predictor of restenosis, target vessel revascularisation (TVR) and subacute stent thrombosis (ST), even in the drug-eluting stent (DES) era. Stent balloons are usually semi-compliant and thus even high-pressure inflation may not achieve uniform or optimal stent expansion. Post-dilatation with non-compliant (NC) balloons after stent deployment has been shown to enhance stent expansion and could reduce TVR and ST. Based on supporting evidence and in the absence of large prospective randomised outcome-based trials, post-dilatation with an NC balloon to achieve optimal stent expansion and maximal luminal area is a logical technical recommendation, particularly in complex lesion subsets.

  10. Drug eluting biliary stents to decrease stent failure rates: A review of the literature

    PubMed Central

    Shatzel, Joseph; Kim, Jisoo; Sampath, Kartik; Syed, Sharjeel; Saad, Jennifer; Hussain, Zilla H; Mody, Kabir; Pipas, J Marc; Gordon, Stuart; Gardner, Timothy; Rothstein, Richard I

    2016-01-01

    Biliary stenting is clinically effective in relieving both malignant and non-malignant obstructions. However, there are high failure rates associated with tumor ingrowth and epithelial overgrowth as well as internally from biofilm development and subsequent clogging. Within the last decade, the use of prophylactic drug eluting stents as a means to reduce stent failure has been investigated. In this review we provide an overview of the current research on drug eluting biliary stents. While there is limited human trial data regarding the clinical benefit of drug eluting biliary stents in preventing stent obstruction, recent research suggests promise regarding their safety and potential efficacy. PMID:26839648

  11. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    PubMed Central

    2010-01-01

    Summary Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. Findings The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4·0%) events of disabling stroke or death in the stenting group compared with 27 (3·2%) events in the endarterectomy group (hazard ratio [HR] 1·28, 95% CI 0·77–2·11). The incidence of stroke, death, or procedural myocardial infarction was 8·5% in the stenting group compared with 5·2% in the endarterectomy group (72 vs 44 events; HR 1·69, 1·16–2·45, p=0·006). Risks of any stroke (65 vs 35 events; HR 1·92, 1·27–2·89) and all-cause death (19 vs seven events; HR 2·76, 1·16–6·56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0·0197). Interpretation Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery. Funding Medical Research Council, the Stroke Association, Sanofi-Synthélabo, European Union. PMID:20189239

  12. Determining clinical benefits of drug-eluting coronary stents according to the population risk profile: a meta-regression from 31 randomized trials.

    PubMed

    Moreno, Raul; Martin-Reyes, Roberto; Jimenez-Valero, Santiago; Sanchez-Recalde, Angel; Galeote, Guillermo; Calvo, Luis; Plaza, Ignacio; Lopez-Sendon, Jose-Luis

    2011-04-01

    The use of drug-eluting stents (DES) in unfavourable patients has been associated with higher rates of clinical complications and stent thrombosis, and because of that concerns about the use of DES in high-risk settings have been raised. This study sought to demonstrate that the clinical benefit of DES increases as the risk profile of the patients increases. A meta-regression analysis from 31 randomized trials that compared DES and bare-metal stents, including overall 12,035 patients, was performed. The relationship between the clinical benefit of using DES (number of patients to treat [NNT] to prevent one episode of target lesion revascularization [TLR]), and the risk profile of the population (rate of TLR in patients allocated to bare-metal stents) in each trial was evaluated. The clinical benefit of DES increased as the risk profile of each study population increased: NNT for TLR=31.1-1.2 (TLR for bare-metal stents); p<0.001. The use of DES was safe regardless of the risk profile of each study population, since the effect of DES in mortality, myocardial infarction, and stent thrombosis, was not adversely affected by the risk profile of each study population (95% confidence interval for β value 0.09 to 0.11, -0.12 to 0.19, and -0.03 to-0.15 for mortality, myocardial infarction, and stent thrombosis, respectively). The clinical benefit of DES increases as the risk profile of the patients increases, without affecting safety. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  13. Stent-mediated gene and drug delivery for cardiovascular disease and cancer: A brief insight.

    PubMed

    Krishnagopal, Akshaya; Reddy, Aakash; Sen, Dwaipayan

    2017-05-01

    This review concisely recapitulates the different existing modes of stent-mediated gene/drug delivery, their considerable advancement in clinical trials and a rationale for other merging new technologies such as nanotechnology and microRNA-based therapeutics, in addition to addressing the limitations in each of these perpetual stent platforms. Over the past decade, stent-mediated gene/drug delivery has materialized as a hopeful alternative for cardiovascular disease and cancer in contrast to routine conventional treatment modalities. Regardless of the phenomenal recent developments achieved by coronary interventions and cancer therapies that employ gene and drug-eluting stents, practical hurdles still remain a challenge. The present review highlights the limitations that each of the existing stent-based gene/drug delivery system encompasses and therefore provides a vision for the future with respect to discovering an ideal stent therapeutic platform that would circumvent all the practical hurdles witnessed with the existing technology. Further study of the improvisation of next-generation drug-eluting stents has helped to overcome the issue of restenosis to some extent. However, current stent formulations fall short of the anticipated clinically meaningful outcomes and there is an explicit need for more randomized trials aiming to further evaluate stent platforms in favour of enhanced safety and clinical value. Gene-eluting stents may hold promise in contributing new ideas for stent-based prevention of in-stent restenosis through genetic interventions by capitalizing on a wide variety of molecular targets. Therefore, the central consideration directs us toward finding an ideal stent therapeutic platform that would tackle all of the gaps in the existing technology. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Cost-effectiveness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitäts Trial (BASKET): an 18-month analysis.

    PubMed

    Brunner-La Rocca, Hans Peter; Kaiser, Christoph; Bernheim, Alain; Zellweger, Michael J; Jeger, Raban; Buser, Peter T; Osswald, Stefan; Pfisterer, Matthias

    2007-11-03

    Our aim was to determine whether drug-eluting stents are good value for money in long-term, everyday practice. We did an 18-month cost-effectiveness analysis of the Basel Stent KostenEffektivitäts Trial (BASKET), which randomised 826 patients 2:1 to drug-eluting stents (n=545) or to bare-metal stents (281). We used non-parametric bootstrap techniques to determine incremental cost-effectiveness ratios (ICERs) of drug-eluting versus bare-metal stents, to compare low-risk (> or =3.0 mm stents in native vessels; n=558, 68%) and high-risk patients (<3.0 mm stents/bypass graft stenting; n=268, 32%), and to do sensitivity analyses by altering costs and event rates in the whole study sample and in predefined subgroups. Quality-adjusted life-years (QALYs) were assessed by EQ-5D questionnaire (available in 703/826 patients). Overall costs were higher for patients with drug-eluting stents than in those with bare-metal stents (11,808 euros [SD 400] per patient with drug-eluting stents and 10,450 euros [592] per patient with bare-metal stents, mean difference 1358 euros [717], p<0.0001), due to higher stent costs. We calculated an ICER of 64,732 euros to prevent one major adverse cardiac event, and of 40,467 euros per QALY gained. Stent costs, number of events, and QALYs affected ICERs most, but unrealistic alterations would have been required to achieve acceptable cost-effectiveness. In low-risk patients, the probability of drug-eluting stents achieving an arbitrary ICER of 10,000 euros or less to prevent one major adverse cardiac event was 0.016; by contrast, it was 0.874 in high-risk patients. If used in all patients, drug-eluting stents are not good value for money, even if prices were substantially reduced. Drug-eluting stents are cost effective in patients needing small vessel or bypass graft stenting, but not in those who require large native vessel stenting.

  15. To stent or not to stent: the use of transanastomotic biliary stents in liver transplantation and patient outcomes.

    PubMed

    Ong, Michelle; Slater, Kellee; Hodgkinson, Peter; Dunn, Nathan; Fawcett, Jonathan

    2018-06-01

    There is no substantial evidence for the use of biliary stents in bile duct reconstruction during liver transplantation. A longitudinal, retrospective cohort study was performed to compare biliary complications between stented and non-stented patients between 2011 and 2015 at the Princess Alexandra Hospital, Brisbane, Australia. We found no significant difference in biliary complications between stented and non-stented groups. Stented patients were 3.31 times as likely to require subsequent intervention, mainly in the form of stent removal. These results suggest that there is limited benefit in the placement of endobiliary stents in liver transplantation. Given that this was purely an observational study, causality cannot be proven and a prospective cohort trial would be beneficial in further defining these relationships. © 2018 Royal Australasian College of Surgeons.

  16. Carotid artery stents on CT angiography: in vitro comparison of different stent designs and sizes using 16-, 64- and 320-row CT scanners.

    PubMed

    Lettau, Michael; Kotter, Elmar; Bendszus, Martin; Hähnel, Stefan

    2014-10-01

    CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Design of the multicenter standardized supervised exercise training intervention for the claudication: exercise vs endoluminal revascularization (CLEVER) study.

    PubMed

    Bronas, Ulf G; Hirsch, Alan T; Murphy, Timothy; Badenhop, Dalynn; Collins, Tracie C; Ehrman, Jonathan K; Ershow, Abby G; Lewis, Beth; Treat-Jacobson, Diane J; Walsh, M Eileen; Oldenburg, Niki; Regensteiner, Judith G

    2009-11-01

    The CLaudication: Exercise Vs Endoluminal Revascularization (CLEVER) study is the first randomized, controlled, clinical, multicenter trial that is evaluating a supervised exercise program compared with revascularization procedures to treat claudication. In this report, the methods and dissemination techniques of the supervised exercise training intervention are described. A total of 217 participants are being recruited and randomized to one of three arms: (1) optimal medical care; (2) aortoiliac revascularization with stent; or (3) supervised exercise training. Of the enrolled patients, 84 will receive supervised exercise therapy. Supervised exercise will be administered according to a protocol designed by a central CLEVER exercise training committee based on validated methods previously used in single center randomized control trials. The protocol will be implemented at each site by an exercise committee member using training methods developed and standardized by the exercise training committee. The exercise training committee reviews progress and compliance with the protocol of each participant weekly. In conclusion, a multicenter approach to disseminate the supervised exercise training technique and to evaluate its efficacy, safety and cost-effectiveness for patients with claudication due to peripheral arterial disease (PAD) is being evaluated for the first time in CLEVER. The CLEVER study will further establish the role of supervised exercise training in the treatment of claudication resulting from PAD and provide standardized methods for use of supervised exercise training in future PAD clinical trials as well as in clinical practice.

  18. Detailed analysis of periprocedural strokes in patients undergoing intracranial stenting in Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis (SAMMPRIS).

    PubMed

    Fiorella, David; Derdeyn, Colin P; Lynn, Michael J; Barnwell, Stanley L; Hoh, Brian L; Levy, Elad I; Harrigan, Mark R; Klucznik, Richard P; McDougall, Cameron G; Pride, G Lee; Zaidat, Osama O; Lutsep, Helmi L; Waters, Michael F; Hourihane, J Maurice; Alexandrov, Andrei V; Chiu, David; Clark, Joni M; Johnson, Mark D; Torbey, Michel T; Rumboldt, Zoran; Cloft, Harry J; Turan, Tanya N; Lane, Bethany F; Janis, L Scott; Chimowitz, Marc I

    2012-10-01

    Enrollment in the Stenting and Aggressive Medical Management for Preventing Recurrent stroke in Intracranial Stenosis (SAMMPRIS) trial was halted due to the high risk of stroke or death within 30 days of enrollment in the percutaneous transluminal angioplasty and stenting arm relative to the medical arm. This analysis focuses on the patient and procedural factors that may have been associated with periprocedural cerebrovascular events in the trial. Bivariate and multivariate analyses were performed to evaluate whether patient and procedural variables were associated with cerebral ischemic or hemorrhagic events occurring within 30 days of enrollment (termed periprocedural) in the percutaneous transluminal angioplasty and stenting arm. Of 224 patients randomized to percutaneous transluminal angioplasty and stenting, 213 underwent angioplasty alone (n=5) or with stenting (n=208). Of these, 13 had hemorrhagic strokes (7 parenchymal, 6 subarachnoid), 19 had ischemic stroke, and 2 had cerebral infarcts with temporary signs within the periprocedural period. Ischemic events were categorized as perforator occlusions (13), embolic (4), mixed perforator and embolic (2), and delayed stent occlusion (2). Multivariate analyses showed that higher percent stenosis, lower modified Rankin score, and clopidogrel load associated with an activated clotting time above the target range were associated (P ≤ 0.05) with hemorrhagic stroke. Nonsmoking, basilar artery stenosis, diabetes, and older age were associated (P ≤ 0.05) with ischemic events. Periprocedural strokes in SAMMPRIS had multiple causes with the most common being perforator occlusion. Although risk factors for periprocedural strokes could be identified, excluding patients with these features from undergoing percutaneous transluminal angioplasty and stenting to lower the procedural risk would limit percutaneous transluminal angioplasty and stenting to a small subset of patients. Moreover, given the small number of events, the present data should be used for hypothesis generation rather than to guide patient selection in clinical practice. Clinical Trial Registration Information- URL: http://clinicaltrials.gov. Unique Identifier: NCT00576693.

  19. Impact of SAMMPRIS on the future of intracranial atherosclerotic disease management: polling results from the ICAD symposium at the International Stroke Conference.

    PubMed

    Zaidat, Osama O; Castonguay, Alicia C; Nguyen, Thanh N; Becker, Kyra J; Derdeyn, Colin P; Nelson, Peter K; Amarenco, Pierre; Brott, Thomas G

    2014-04-01

    There are few data regarding the effect of the Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis (SAMMPRIS) trial results on the management of intracranial atherosclerotic disease (ICAD). We sought to understand the impact of the SAMMPRIS trial on current ICAD clinical practices and future trial design. During the ICAD symposium at the 2012 International Stroke Conference, electronic data were collected regarding attendees' clinical management of ICAD and opinions on the feasibility of future trials post-SAMMPRIS. 217 attendees from different specialties, including neurologists (57%), neurointerventionalists (9%) and neurosurgeons (5%), participated in the session. The majority of respondents (77%) indicated that the results of SAMMPRIS have impacted their consideration for intracranial stenting. Post-SAMMPRIS, 84% selected 'SAMMPRIS-style' medical management for the treatment of ICAD. For patients with ICAD who failed aggressive medical therapy, 82% would consider an alternative approach to continuing medical therapy (30% considered clinical trial enrollment, 28% suggested angioplasty and stenting and 24% angioplasty). The majority of participants (85%) were willing to randomize patients with symptomatic ICAD in future trials. For the next ICAD trial, 29% indicated that angioplasty alone should be compared with aggressive medical therapy. Our polling results suggest that the SAMMPRIS trial has had an impact on the current treatment of ICAD. Treatment of patients who failed medical therapy varied widely from aggressive medical therapy to balloon angioplasty, stenting or enrollment in future clinical trials. The willingness to continue clinical trials and randomize patients supports the need for future ICAD studies.

  20. Stent thrombosis and major clinical events at 3 years after zotarolimus-eluting or sirolimus-eluting coronary stent implantation: a randomised, multicentre, open-label, controlled trial.

    PubMed

    Camenzind, Edoardo; Wijns, William; Mauri, Laura; Kurowski, Volkhard; Parikh, Keyur; Gao, Runlin; Bode, Christoph; Greenwood, John P; Boersma, Eric; Vranckx, Pascal; McFadden, Eugene; Serruys, Patrick W; O'Neil, William W; Jorissen, Brenda; Van Leeuwen, Frank; Steg, Ph Gabriel

    2012-10-20

    We sought to compare the long-term safety of two devices with different antiproliferative properties: the Endeavor zotarolimus-eluting stent (E-ZES; Medtronic, Inc) and the Cypher sirolimus-eluting stent (C-SES; Cordis, Johnson & Johnson) in a broad group of patients and lesions. Between May 21, 2007 and Dec 22, 2008, we recruited 8791 patients from 36 recruiting countries to participate in this open-label, multicentre, randomised, superiority trial. Eligible patients were those aged 18 years or older undergoing elective, unplanned, or emergency procedures in native coronary arteries. Patients were randomly assigned to either receive E-ZES and C-SES (ratio 1:1). Randomisation was stratified per centre with varying block sizes of four, six, or eight patients, and concealed with a central telephone-based or web-based allocation service. The primary outcome was definite or probable stent thrombosis at 3 years and was analysed by intention to treat. Patients and investigators were aware of treatment assignment. This trial is registered with ClinicalTrials.gov, number NCT00476957. PROTECT randomised 8791 patients, of whom 8709 provided consent to participate and were eligible: 4357 were allocated to the E-ZES group and 4352 patients to the C-SES group. At 3 years, rates of definite or probable stent thrombosis did not differ between groups (1·4% for E-ZES [predicted: 1·5%] vs 1·8% [predicted: 2·5%] for C-SES; hazard ratio [HR] 0·81, 95% CI 0·58-1·14, p=0·22). Dual antiplatelet therapy was used in 8402 (96%) patients at discharge, 7456 (88%) at 1 year, 3041 (37%) at 2 years, and 2364 (30%) at 3 years. No evidence of superiority of E-ZES compared with C-SES in definite or probable stent thrombosis rates was noted at 3 years. Time analysis suggests a difference in definite or probable stent thrombosis between groups is emerging over time, and a longer follow-up is therefore needed given the clinical relevance of stent thrombosis. Medtronic, Inc. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Stent deployment protocol for optimized real-time visualization during endovascular neurosurgery.

    PubMed

    Silva, Michael A; See, Alfred P; Dasenbrock, Hormuzdiyar H; Ashour, Ramsey; Khandelwal, Priyank; Patel, Nirav J; Frerichs, Kai U; Aziz-Sultan, Mohammad A

    2017-05-01

    Successful application of endovascular neurosurgery depends on high-quality imaging to define the pathology and the devices as they are being deployed. This is especially challenging in the treatment of complex cases, particularly in proximity to the skull base or in patients who have undergone prior endovascular treatment. The authors sought to optimize real-time image guidance using a simple algorithm that can be applied to any existing fluoroscopy system. Exposure management (exposure level, pulse management) and image post-processing parameters (edge enhancement) were modified from traditional fluoroscopy to improve visualization of device position and material density during deployment. Examples include the deployment of coils in small aneurysms, coils in giant aneurysms, the Pipeline embolization device (PED), the Woven EndoBridge (WEB) device, and carotid artery stents. The authors report on the development of the protocol and their experience using representative cases. The stent deployment protocol is an image capture and post-processing algorithm that can be applied to existing fluoroscopy systems to improve real-time visualization of device deployment without hardware modifications. Improved image guidance facilitates aneurysm coil packing and proper positioning and deployment of carotid artery stents, flow diverters, and the WEB device, especially in the context of complex anatomy and an obscured field of view.

  2. Longer- Versus Shorter-Duration Dual-Antiplatelet Therapy After Drug-Eluting Stent Placement: A Systematic Review and Meta-analysis.

    PubMed

    Spencer, Frederick A; Prasad, Manya; Vandvik, Per O; Chetan, Devin; Zhou, Qi; Guyatt, Gordon

    2015-07-21

    The appropriate duration of dual-antiplatelet therapy (DAPT) after drug-eluting stent (DES) placement remains controversial. To summarize data on clinical outcomes with longer- versus shorter-duration DAPT after DES placement in adults with coronary artery disease. Ovid MEDLINE and EMBASE, 1996 to 27 March 2015, and manual screening of references. Randomized, controlled trials comparing longer- versus shorter-duration DAPT after DES placement. Two reviewers screened potentially eligible articles; extracted data on populations, interventions, and outcomes; assessed risk of bias; and used the Grading of Recommendations Assessment, Development and Evaluation guidelines to rate overall confidence in effect estimates. Among 1010 articles identified, 9 trials including 29,531 patients were eligible; data were complete for 28,808 patients. Moderate-quality evidence showed that longer-duration DAPT decreased risk for myocardial infarction (risk ratio [RR], 0.73 [95% CI, 0.58 to 0.92]) and increased mortality (RR, 1.19 [CI, 1.04 to 1.36]). High-quality evidence showed that DAPT increased risk for major bleeding (RR, 1.63 [CI, 1.34 to 1.99]). Confidence in estimates were decreased owing to imprecision for most outcomes (particularly myocardial infarction), risk of bias from limited blinding in 7 of 9 studies, indirectness due to variability in use of first- and second-generation stents, and off-protocol use of DAPT in some studies. Extended DAPT is associated with approximately 8 fewer myocardial infarctions per 1000 treated patients per year but 6 more major bleeding events than shorter-duration DAPT. Because absolute effects are very small and closely balanced, decisions regarding the duration of DAPT therapy must take into account patients' values and preference. None.

  3. Early Removal of Double-J Stents Decreases Urinary Tract Infections in Living Donor Renal Transplantation: A Prospective, Randomized Clinical Trial.

    PubMed

    Liu, S; Luo, G; Sun, B; Lu, J; Zu, Q; Yang, S; Zhang, X; Dong, J

    2017-03-01

    The optimal timing for stent removal after renal transplantation remains controversial. This article describes an interim analysis of a randomized, prospective, double-blind trial aimed at detecting differences in urological complications between early ureteral stent removal at 1 week and routine ureteral stent removal at 4 weeks. Between October 2010 and March 2015, 103 patients who underwent living donor renal transplantation at a single center were pre-operatively randomly assigned to the early ureteral stent removal (at 1 week) group or the routine ureteral stent removal (at 4 weeks) group. Urinary symptoms, auxiliary examination results, and obstruction events were recorded during 3 months of follow-up. A cost analysis of both the hospitalization and postoperative periods was discussed. In total, 52 patients in the 1-week stent group and 51 patients in the 4-week stent group were analyzed. No serious adverse events were reported. Three episodes of urinary tract infections (UTIs) occurred in the 1-week stent group, and 18 such episodes were recorded in the 4-week stent group (5.8% vs 29.4%; P = .002). After adjusting for age, sex, ischemia time, renal artery number, body mass index, multiple arteries, and associated medical illness, regression analysis indicated that only stent duration was associated with UTI (OR, 8.791; 95% CI, 1.984-38.943; P = .004). The results of our study demonstrate that ureteral stent removal at 1 week reduces the risk of UTIs compared with routine removal at 4 weeks. Similar effects of ureteral stent removal on complication rates are observed for these two removal times. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Systematic review and meta-analysis of metal versus plastic stents for preoperative biliary drainage in resectable periampullary or pancreatic head tumors.

    PubMed

    Crippa, S; Cirocchi, R; Partelli, S; Petrone, M C; Muffatti, F; Renzi, C; Falconi, M; Arcidiacono, P G

    2016-09-01

    Preoperative biliary drainage (PBD) with stenting increases complications compared with surgery without PBD. Metallic stents are considered superior to plastic stents when considering stent-related complications. Aim of the present systematic review and meta-analysis is to compare the rate of endoscopic re-intervention before surgery and postoperative outcomes of metal versus plastic stents in patients with resectable periampullary or pancreatic head neoplasms. We conducted a bibliographic research using the National Library of Medicine's PubMed database, including both randomized controlled trials (RCTs) and non-RCTs. Quantitative synthesis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Statistical heterogeneity was assessed using the I(2) tests. One RCT and four non-RCTs were selected, including 704 patients. Of these, 202 patients (29.5%) were treated with metal stents and 502 (70.5%) with plastic stents. The majority of patients (86.4%) had pancreatic cancer. The rate of endoscopic re-intervention after preoperative biliary drainage was significantly lower in the metal stent (3.4%) than in the plastic stent (14.8%) group (p < 0.0001). The rate of postoperative pancreatic fistula was significantly lower in the meta stent group as well (5.1% versus 11.8%, p = 0.04). The rate of post-operative surgical complications and of - post-operative mortality did not differ between the two groups. Although the present systematic review and meta-analysis demonstrates that metal stent are more effective than plastic stents for PBD in patients with resectable periampullary tumors, randomized controlled trials are needed in order to confirm these data with a higher level of evidence. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents.

    PubMed

    Uthamaraj, Susheil; Tefft, Brandon J; Jana, Soumen; Hlinomaz, Ota; Kalra, Manju; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S

    2016-10-26

    Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.

  6. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with coronary artery disease: three-year follow-up of the COMPARE II (Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent) trial.

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Puricel, Serban; Slagboom, Ton; Goy, Jean-Jacques; den Heijer, Peter; van der Ent, Martin

    2015-07-01

    The aim of this analysis was to compare the long-term safety and efficacy of the biodegradable polymer biolimus-eluting stent (BES) with that of the durable polymer everolimus-eluting stent (EES). The COMPARE II study was a prospective, randomised, multicentre, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BES or EES. The pre-specified endpoint at three years was major adverse cardiac events (MACE), a composite of cardiac death, non-fatal myocardial infarction (MI), or target vessel revascularisation (TVR). Moreover, the combined endpoint all-cause death or MI was analysed as a safety, and TVR as an efficacy measure. Three-year follow-up was available in 2,683 patients (99.1%). At three years, MACE occurred in 213 patients (11.9%) in the BES group and in 101 patients (11.1 %) in the EES group (p=0.57). The rate of the combined safety endpoint all-cause death or MI was 9.3% in the BES group vs. 8.4% (p=0.52), while the efficacy measure TVR was 7.6% in BES vs. 6.5% (p=0.27). Interestingly, definite stent thrombosis rates did not differ between groups (1.2% for BES vs. 0.8%, p=0.33). At three-year follow-up, MACE as well as safety and efficacy measures including stent thrombosis were not statistically different between the biodegradable polymer-coated BES and the durable polymer-coated EES. ClinicalTrials.gov Identifier: NCT01233453.

  7. Primary Self-EXPANDing Nitinol Stenting vs Balloon Angioplasty With Optional Bailout Stenting for the Treatment of Infrapopliteal Artery Disease in Patients With Severe Intermittent Claudication or Critical Limb Ischemia (EXPAND Study).

    PubMed

    Schulte, Karl-Ludwig; Pilger, Ernst; Schellong, Sebastian; Tan, Kong Ten; Baumann, Frederic; Langhoff, Ralf; Torsello, Giovanni; Zeller, Thomas; Amendt, Klaus; Brodmann, Marianne

    2015-10-01

    To compare primary placement of a self-expanding nitinol stent to percutaneous transluminal angioplasty (PTA) with bailout stenting in infrapopliteal arteries of patients with severe intermittent claudication or critical limb ischemia (CLI). In the EXPAND trial (ClinicalTrials.gov; identifier NCT00906022), 92 patients (mean age 72.9±9.5 years; 62 men) undergoing treatment for infrapopliteal stenosis in 11 European centers were randomized 1:1 to either self-expanding nitinol stenting with the Astron Pulsar/Pulsar-18 nitinol stent or PTA with bailout stenting. The primary endpoint was sustainable clinical improvement after 12 months, defined as a ≥1-category increase for Rutherford category 3 patients or a ≥2-category increase for CLI patients (Rutherford categories 4/5) compared with baseline. Furthermore, target lesion revascularization (TLR), mortality, and amputation were assessed after 12 months. Sustained clinical improvement at 1 year was observed in 74.3% of the patients treated with primary stenting and in 68.6% of the patients treated with PTA and bailout stenting (p>0.05). Kaplan-Meier estimates of freedom from TLR (76.6% and 77.6%), mortality (7.4% vs 2.1%), and amputation [8.9% (major 6.7%) vs 13.2% (major 8.7%)] at 1 year were not significantly different. Primary self-expanding nitinol stenting did not show statistically different clinical outcomes compared to angioplasty with bailout stenting for infrapopliteal lesions. © The Author(s) 2015.

  8. Rationale of a novel study design for the BIOFLOW V study, a prospective, randomized multicenter study to assess the safety and efficacy of the Orsiro sirolimus-eluting coronary stent system using a Bayesian approach.

    PubMed

    Doros, Gheorghe; Massaro, Joseph M; Kandzari, David E; Waksman, Ron; Koolen, Jacques J; Cutlip, Donald E; Mauri, Laura

    2017-11-01

    Traditional study design submitted to the Food and Drug Administration to test newer drug-eluting stents (DES) for marketing approval is the prospective randomized controlled trial. However, several DES have extensive clinical data from trials conducted outside the United States that have led to utilization of a novel design using the Bayesian approach. This design was proposed for testing DES with bioresorbable polymer compared with DES most commonly in use today that use durable polymers for drug elution. This prospective, multicenter, randomized, controlled trial is designed to assess the safety and efficacy of the Orsiro bioresorbable polymer sirolimus-eluting stent (BP SES). Up to 1,334 subjects with up to 3 de novo or restenotic coronary artery lesions who qualify for percutaneous coronary intervention with stenting will be randomized 2:1 to the BP SES versus the Xience durable polymer everolimus-eluting stent (DP EES). Data from this trial will be combined with data from 2 similarly designed trials that also randomize subjects to BP SES and DP EES (BIOFLOW II, N=452 and BIOFLOW IV, N=579) by using a Bayesian approach. The primary end point is target lesion failure at 12 months post index procedure, defined as cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization, and the primary analysis is a test of noninferiority of the BP SES versus DP EES on the primary end point according to a noninferiority delta of 3.85%. Secondary end points include stent thrombosis and the individual components of target lesion failure. Subjects will be followed for 5 years after randomization. The BIOFLOW V trial offers an opportunity to assess clinical outcomes in patients treated with coronary revascularization using the Orsiro BP SES relative to a commonly used DP EES. The use of a Bayesian analysis combines a large randomized cohort of patients 2 two smaller contributing randomized trials to augment the efficiency of the comparison. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. A prospective, randomized study of the patency period of the plastic antireflux biliary stent: an interim analysis.

    PubMed

    Leong, Quan Wai; Shen, Mira L; Au, Kim W; Luo, Derek; Lau, James Y; Wu, Justin C; Chan, Francis K; Sung, Joseph J

    2016-02-01

    There is as yet no ideal design of a plastic biliary stent with the longest patency period. To study the safety and effective patency period of a new plastic antireflux biliary stent in the clinical setting. We conducted a prospective, randomized trial to compare the patency of 2 similar plastic biliary stents, one of which has an antiduodenobiliary reflux property. The study was conducted at 2 separate tertiary centers in 2 countries. Patients with inoperable distal malignant biliary obstruction were recruited. One of the 2 types of plastic stents under study was randomly chosen and inserted in the common bile duct of the study subjects. The subjects were followed until the end of study or occlusion occurrence. Our primary endpoint was the time to stent occlusion in days, with stent-related adverse events and all-cause mortality the secondary endpoints. A total of 16 subjects were recruited for the study; 7 were allocated to group A (ordinary Tannenbaum stent) and 9 to group B (antireflux biliary stent). Five of 7 subjects (71%) in group B had stent occlusion within 8 days, and the primary end point was reached in all 7 subjects within 30 days, whereas the primary endpoint was not reached within 30 days in any of the subjects in group A. Our data showed a significantly shorter stent patency period in group B compared with group A (P < .003). Small sample size. Routine use of antireflux plastic biliary stents in the palliative management of malignant biliary obstructions cannot be recommended at present. (Clinical trial registration number: NCT01142921.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  10. Metal versus plastic stents for drainage of malignant biliary obstruction before primary surgical resection.

    PubMed

    Song, Tae Jun; Lee, Jae Hoon; Lee, Sang Soo; Jang, Ji Woong; Kim, Jung Wook; Ok, Tae Jin; Oh, Dong Wook; Park, Do Hyun; Seo, Dong Wan; Lee, Sung Koo; Kim, Myung-Hwan; Kim, Song Cheol; Kim, Chul Nam; Yun, Sung Cheol

    2016-11-01

    Preoperative biliary drainage (PBD) with stent placement has been commonly used for patients with malignant biliary obstruction. In PBD, the placement of fully covered self-expandable metal stents (FCSEMSs) may provide better patency duration and a lower incidence of cholangitis compared with plastic stents. We aimed to evaluate which type of stent showed better outcomes in PBD. In this multicenter, prospective randomized trial, we compared PBD with FCSEMSs versus plastic stents in 86 patients with malignant biliary obstruction between January 2012 and December 2014. Patients with obstructive jaundice were randomly assigned to undergo PBD either with plastic stents or FCSEMS placement. Baseline characteristics were not significantly different between the 2 groups. Endoscopic stent placement was technically successful in all patients. Procedure-related adverse events were not significantly different between the 2 groups (plastic vs FCSEMS group; 16.3% vs 16.3%, P = 1.0). Reintervention was required in 16.3% of the plastic stent group and 14.0% of the FCSEMS group (P = .763). The interval to surgery after PBD (plastic vs FCSEMS group; 14.2 ± 8.3 vs 12.3 ± 6.9 days, P = .426) was not significantly different between groups. Surgery-related adverse events occurred in 43.6% of the plastic stent group and 40.0% of the FCSEMS group (P = .755). In patients with resectable malignant biliary obstruction, the outcomes of PBD with plastic stents and FCSEMSs were similar. Considering the cost-effectiveness, PBD with plastic stents may be preferable to FCSEMS placement. (Clinical trial registration number: NCT01789502.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomised controlled trials.

    PubMed

    Cassese, Salvatore; Byrne, Robert A; Ndrepepa, Gjin; Kufner, Sebastian; Wiebe, Jens; Repp, Janika; Schunkert, Heribert; Fusaro, Massimiliano; Kimura, Takeshi; Kastrati, Adnan

    2016-02-06

    Bioresorbable coronary stents might improve outcomes of patients treated with percutaneous coronary interventions. The everolimus-eluting bioresorbable vascular scaffold is the most studied of these stent platforms; however, its performance versus everolimus-eluting metallic stents remains poorly defined. We aimed to assess the efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents in patients with ischaemic heart disease treated with percutaneous revascularisation. We searched Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL), scientific sessions abstracts, and relevant websites for randomised trials investigating everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents published or posted between Nov 30, 2006, and Oct 12, 2015. The primary efficacy outcome was target lesion revascularisation and the primary safety outcome was definite or probable stent (scaffold) thrombosis. Secondary outcomes were target lesion failure (the composite of cardiac death, target-vessel myocardial infarction, or ischaemia-driven target lesion revascularisation), myocardial infarction, death, and in-device late lumen loss. We derived odds ratios (ORs) and weighted mean differences with 95% CIs, and calculated the risk estimates for the main outcomes according to a random-effects model. This study is registered with PROSPERO, number CRD42015026374. We included six trials, comprising data for 3738 patients randomised to receive percutaneous coronary intervention with either an everolimus-eluting bioresorbable vascular scaffold (n=2337) or an everolimus-eluting metallic stent (n=1401). Median follow-up was 12 months (IQR 9-12). Patients treated with bioresorbable vascular scaffolds had a similar risk of target lesion revascularisation (OR 0.97 [95% CI 0.66-1.43]; p=0.87), target lesion failure (1.20 [0.90-1.60]; p=0.21), myocardial infarction (1.36 [0.98-1.89]; p=0.06), and death (0.95 [0.45-2.00]; p=0.89) as those treated with metallic stents. Patients treated with a bioresorbable vascular scaffold had a higher risk of definite or probable stent thrombosis than those treated with a metallic stent (OR 1.99 [95% CI 1.00-3.98]; p=0.05), with the highest risk between 1 and 30 days after implantation (3.11 [1.24-7.82]; p=0.02). Lesions treated with a bioresorbable vascular scaffold had greater in-device late lumen loss than those treated with a metallic stent (weighted mean difference 0.08 [95% CI 0.05-0.12]; p<0.0001). Compared with everolimus-eluting metallic stents, everolimus-eluting bioresorbable vascular scaffolds had similar rates of repeat revascularisation at 1 year of follow-up, despite inferior mid-term angiographic performance. However, patients treated with a bioresorbable vascular scaffold had an increased risk of subacute stent thrombosis. Studies with extended follow-up in a larger number of patients are needed to fully assess the long-term advantages of everolimus-eluting bioresorbable vascular scaffolds. None. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Choices of Stent and Cerebral Protection in the Ongoing ACST-2 Trial: A Descriptive Study.

    PubMed

    de Waard, D D; Halliday, A; de Borst, G J; Bulbulia, R; Huibers, A; Casana, R; Bonati, L H; Tolva, V

    2017-05-01

    Several plaque and lesion characteristics have been associated with an increased risk for procedural stroke during or shortly after carotid artery stenting (CAS). While technical advancements in stent design and cerebral protection devices (CPD) may help reduce the procedural stroke risk, and anatomy remains important, tailoring stenting procedures according to plaque and lesion characteristics might be a useful strategy in reducing stroke associated with CAS. In this descriptive report of the ongoing Asymptomatic Carotid Surgery Trial-2 (ACST-2), it was assessed whether choice for stent and use or type of CPD was influenced by plaque and lesion characteristics. Trial patients who underwent CAS between 2008 and 2015 were included in this study. Chi-square statistics were used to study the effects of plaque echolucency, ipsilateral preocclusive disease (90-99%), and contralateral high-grade stenosis (>50%) or occlusion of the carotid artery on interventionalists' choice for stent and CPD. Differences in treatment preference between specialties were also analysed. In this study, 831 patients from 88 ACST-2 centres were included. Almost all procedures were performed by either interventional radiologists (50%) or vascular surgeons (45%). Plaque echolucency, ipsilateral preocclusive disease (90-99%), and significant contralateral stenosis (>50%) or occlusion did not affect the choice of stent or either the use of cerebral protection and type of CPD employed (i.e., filter/flow reversal). Vascular surgeons used a CPD significantly more often than interventional radiologists (98.6% vs. 76.3%; p < .001), but this choice did not appear to be dependent on patient characteristics. In ACST-2, plaque characteristics and severity of stenosis did not primarily determine interventionalists' choice of stent or use or type of CPD, suggesting that other factors, such as vascular anatomy or personal and centre preference, may be more important. Stent and CPD use was highly heterogeneous among participating European centres. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Randomized Comparison of Ridaforolimusand Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    PubMed Central

    Kandzari, David E.; Smits, Pieter C.; Love, Michael P.; Ben-Yehuda, Ori; Banai, Shmuel; Rob-inson, Simon D.; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y.; Balcells, Mer-cedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R.; Leon, Martin B.; Stone, Gregg W.

    2018-01-01

    BACKGROUND The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. METHODS A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. RESULTS Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, Pnoninferiority=0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P=0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm (Pnoninferiority=0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively (Pnoninferiority=0.01). CONCLUSIONS In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487. PMID:28794001

  14. Age modifies the relative risk of stenting versus endarterectomy for symptomatic carotid stenosis--a pooled analysis of EVA-3S, SPACE and ICSS.

    PubMed

    Bonati, L H; Fraedrich, G

    2011-02-01

    Recent randomised controlled trials comparing carotid artery stenting (CAS) with endarterectomy (CEA) for the treatment of symptomatic carotid stenosis were not powered to investigate differences in risks in specific patient subgroups. We therefore performed a pooled analysis of individual patient data from the Symptomatic Severe Carotid Stenosis trial (EVA-3S), the Stent-Protected Angioplasty versus Carotid Endarterectomy trial (SPACE), and the International Carotid Stenting Study (ICSS). Individual data from all 3433 patients randomised and analysed in these trials were pooled and analysed with fixed-effect binomial regression models adjusted for source trial. The primary outcome event was any stroke or death. In the first 120 days after randomisation (ITT analysis), the primary outcome event occurred in 153/1725 patients in the CAS group (8.9%) compared with 99/1708 patients in the CEA group (5.8%, risk ratio [RR] 1.53, 95% confidence interval [CI] 1.20-1.95, p = 0.0006; absolute risk difference 3.2, 95% CI 1.4-4.9). Age was the only subgroup variable which significantly modified the treatment effect: in patients <70 years old (the median age), the 120-day stroke or death risk was 5.8% in CAS and 5.7% in CEA (RR 1.00, 0.68-1.47); in patients 70 years or older, there was an estimated two-fold increase in risk with CAS over CEA (12.0% vs. 5.9%, RR 2.04, 1.48-2.82, interaction p = 0.0053). Endarterectomy was safer in the short-term than stenting, because of an increased risk of stroke associated with stenting in patients over the age of 70 years. Stenting should be avoided in older patients, but may be as safe as endarterectomy in younger patients. Determination of the efficacy and ultimate balance between the two procedures requires further data on long-term stroke recurrence. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Meta-Analysis of Stenting versus Non-Stenting for the Treatment of Ureteral Stones

    PubMed Central

    Wang, Hai; Man, Libo; Li, Guizhong; Huang, Guanglin; Liu, Ning; Wang, Jianwei

    2017-01-01

    Background and aim Ureteroscopic lithotripsy (URL) and extracorporeal shock wave lithotripsy (ESWL) are two widely used methods for the treatment of ureteral stones. The need for ureteral stenting during these procedures is controversial. In this meta-analysis, we evaluated the benefits and disadvantages of ureteral stents for the treatment of ureteral stones. Methods Databases including PubMed, Embase and Cochrane library were selected for systematic review of randomized controlled trials (RCTs) comparing outcomes with or without stenting during URL and ESWL. Meta-analysis was performed using RevMan 5.3 and STATA 13.0 software. Results We identified 22 RCTs comparing stenting and non-stenting. The stented group was associated with longer operation time (WMD: 4.93; 95% CI: 2.07 to 7.84; p < 0.001), lower stone-free rate (OR: 0.55; 95% CI: 0.34 to 0.89; p = 0.01). In terms of complications, the incidence of hematuria (OR: 3.68; 95% CI: 1.86 to 7.29; p < 0.001), irritative urinary symptoms (OR: 4.40; 95% CI: 2.19 to 9.10; p < 0.001), urinary infection (OR: 2.23; 95% CI: 1.57 to 3.19; p < 0.001), and dysuria (OR: 3.90; 95% CI: 2.51 to 6.07; p < 0.001) were significantly higher in the stented group. No significant differences in visual analogue score (VAS), stricture formation, fever, or hospital stay were found between stenting and non-stenting groups. The risk of unplanned readmissions (OR: 0.63; 95% CI: 0.41 to 0.97; p = 0.04) was higher in the non-stented group. Conclusions Our analysis showed that stenting failed to improve the stone-free rate, and instead, it resulted in additional complications. However, ureteral stents are valuable in preventing unplanned re-hospitalization. Additional randomized controlled trials are still required to corroborate our findings. PMID:28068364

  16. Outcomes with the paclitaxel-eluting stent in patients with acute coronary syndromes: analysis from the TAXUS-IV trial.

    PubMed

    Moses, Jeffrey W; Mehran, Roxana; Nikolsky, Eugenia; Lasala, John M; Corey, Woodrow; Albin, Glenn; Hirsch, Cary; Leon, Martin B; Russell, Mary E; Ellis, Stephen G; Stone, Gregg W

    2005-04-19

    We sought to investigate the outcomes of paclitaxel-eluting stent implantation in patients with unstable angina or non-ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention (PCI). Whether the paclitaxel-eluting stent is safe and effective in patients with acute coronary syndromes (ACS) is unknown. In the TAXUS-IV trial, 1,314 patients with stable or unstable ischemic syndromes undergoing PCI were randomized to treatment with either the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). The results were stratified by the acuity of the presenting clinical syndrome. Acute coronary syndromes were present in 450 patients (34.2%), 237 of whom were assigned to paclitaxel-eluting stents and 213 to bare-metal stents. The baseline and procedural characteristics were well matched between the groups. Clinical outcomes at 30 days were similar with both stents. At one-year follow-up, patients with ACS assigned to the paclitaxel-eluting stent compared to the control stent had strikingly lower rates of target lesion revascularization (TLR) (3.9% vs. 16.0%, p < 0.0001) and major adverse cardiac events (11.1 vs. 21.7%, p = 0.002). By multivariate analysis, ACS was an independent predictor of in-stent restenosis in the cohort treated with bare-metal stents (hazard ratio [HR] = 2.03 [95% confidence interval (CI) 1.05 to 3.92], p = 0.035), while among patients randomized to the paclitaxel-eluting stents, ACS was an independent predictor of freedom from restenosis (HR = 0.27 [95% CI 0.08 to 0.97], p = 0.04). The use of the paclitaxel-eluting TAXUS stent was safe in patients with unstable ischemic syndromes, and was associated with marked reduction of ischemia-driven TLR and adverse cardiac events at one year.

  17. Treatment of spontaneous esophageal rupture with transnasal thoracic drainage and temporary esophageal stent and jejunal feeding tube placement.

    PubMed

    Wu, Gang; Zhao, Yan Shi; Fang, Yi; Qi, Yu; Li, Xiangnan; Jiao, Dechao; Ren, Kewei; Han, Xinwei

    2017-01-01

    Spontaneous rupture of the esophagus is a rare but life-threatening thoracic emergency, with high rates of clinical misdiagnosis and mortality. This article summarizes our experience in the treatment of spontaneous esophageal rupture with transnasal thoracic drainage and temporary esophageal stent and jejunal feeding tube placement. We retrospectively assessed the medical records of 19 patients with spontaneous esophageal rupture treated using our intervention protocol. Patients received local anesthesia and sedation prior to undergoing transnasal drainage catheter placement into the thoracic abscess cavity, followed by temporary esophageal stent and jejunal feeding tube placement. After the operation, abscess lavage, nutritional support, and anti-inflammatory treatment were given. The transnasal thoracic drainage catheter, esophageal stent, and feeding tube were removed after the healing of the abscess cavity. In all, 19 covered esophageal stents were placed in 19 patients with spontaneous esophageal rupture. All operations were technically successful. After an average of 84.06 days, the stents were successfully removed from 17 patients. No cases of massive hemorrhage, esophageal rupture, or other complications occurred during stent removal. An 82-year-old patient died of heart failure 2 months after the operation. One patient died of sudden massive hematemesis and hematochezia 55 days after the operation. In one patient, the esophageal injury failed to heal completely. Our treatment protocol is simple, minimally invasive, and efficacious and may be an alternative for patients who are not candidates for surgery, have a high risk of postoperative complications, or wish to undergo minimally invasive surgery. Therapeutic study, level V.

  18. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p < 0.001). At 3 years, the rates of cardiac death (2% vs. 1%), myocardial infarction (4% vs. 5%) and target vessel revascularization (9% vs. 5%) were similar in the DEB and EES arms. Importantly, however, at 3 years, the rate of target lesion revascularization was significantly lower in the EES arm (2% vs. 8%; p = 0.04; hazard ratio: 0.23; 95% confidence interval: 0.06 to 0.93). The need for "late" (>1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Culprit lesion thrombus burden after manual thrombectomy or percutaneous coronary intervention-alone in ST-segment elevation myocardial infarction: the optical coherence tomography sub-study of the TOTAL (ThrOmbecTomy versus PCI ALone) trial.

    PubMed

    Bhindi, Ravinay; Kajander, Olli A; Jolly, Sanjit S; Kassam, Saleem; Lavi, Shahar; Niemelä, Kari; Fung, Anthony; Cheema, Asim N; Meeks, Brandi; Alexopoulos, Dimitrios; Kočka, Viktor; Cantor, Warren J; Kaivosoja, Timo P; Shestakovska, Olga; Gao, Peggy; Stankovic, Goran; Džavík, Vladimír; Sheth, Tej

    2015-08-01

    Manual thrombectomy has been proposed as a strategy to reduce thrombus burden during primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI). However, the effectiveness of manual thrombectomy in reducing thrombus burden is uncertain. In this substudy of the TOTAL (ThrOmbecTomy versus PCI ALone) trial, we compared the thrombus burden at the culprit lesion using optical coherence tomography (OCT) in patients treated with thrombectomy vs. PCI-alone. The TOTAL trial (N = 10 732) was an international, multicentre, randomized trial of thrombectomy (using the Export catheter, Medtronic Cardiovascular, Santa Rosa, CA, USA) in STEMI patients treated with primary PCI. The OCT substudy prospectively enrolled 214 patients from 13 sites in 5 countries. Optical coherence tomography was performed immediately after thrombectomy or PCI-alone and then repeated after stent deployment. Thrombus quantification was performed by an independent core laboratory blinded to treatment assignment. The primary outcome of pre-stent thrombus burden as a percentage of segment analysed was 2.36% (95% CI: 1.73-3.22) in the thrombectomy group and 2.88% (95% CI: 2.12-3.90) in the PCI-alone group (P = 0.373). Absolute pre-stent thrombus volume was not different (2.99 vs. 3.74 mm(3), P = 0.329). Other secondary outcomes of pre-stent quadrants of thrombus, post-stent atherothrombotic burden, and post-stent atherothrombotic volume were not different between groups. Manual thrombectomy did not reduce pre-stent thrombus burden at the culprit lesion compared with PCI-alone. Both strategies were associated with low thrombus burden at the lesion site after the initial intervention to restore flow. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  20. Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents

    PubMed Central

    Uthamaraj, Susheil; Tefft, Brandon J.; Jana, Soumen; Hlinomaz, Ota; Kalra, Manju; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2016-01-01

    Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters. PMID:27805589

  1. Beneficial Effect of a Resorbable Biliary Stent in Living Donor Liver Transplantation.

    PubMed

    Sánchez-Cabús, Santiago; Calatayud, David; Ferrer, Joana; Molina, Víctor; Pavel, Mihai-Calin; Sampson, Jaime; Saavedra, David; Fondevila, Constantino; Fuster, Josep; García-Valdecasas, Juan Carlos

    2016-01-01

    Living donor liver transplantation (LDLT) entails a significant number of bile duct complications. We aimed to diminish the biliary complication rate with the use of a resorbable biliary stent (RBS) during LDLT. The objective of this study is to describe the surgical techniques and the associated outcomes, especially in terms of safety, of RBS use in LDLT. From 2011 to 2014, 12 LDLT recipients were enrolled in a clinical trial with the use of a specifically designed RBS. These patients were followed according to the clinical protocol. Specific complications derived from RBS as well as biliary complications were recorded. One patient underwent early retransplantation due to a small-for-size syndrome. None of the patients had a complication attributable to the placement, remaining in place, or degradation of the stent. Four of the remaining patients presented with a biliary complication: 1 (9.1%) with a biliary leak alone, 1 (9.1%) with a biliary stenosis alone, and 2 (18.2%) with both. However, none of the leaks could be directly attributed to the RBS. Patient and graft 1-year survival was 100 and 91.7%, respectively. The use of an RBS in LDLT is not associated with complications, and initial results regarding efficacy and safety are encouraging. The need for a larger and prospective study is warranted. © 2016 S. Karger AG, Basel.

  2. [Stent and surgery for symptomatic carotid stenosis. SPACE study results].

    PubMed

    Ringleb, P A; Hacke, W

    2007-10-01

    The SPACE trial compared risk and effectiveness of stent-supported angioplasty (CAS) vs carotid endarterectomy (CEA) using a noninferiority design in patients with symptomatic stenoses. Intention-to-treat analysis of the entire study population of 1,214 patients showed that primary endpoint events (ipsilateral stroke or death between randomisation and day 30) occurred in 6.92% of the CAS group and 6.45% of the CEA group. The 95% confidence interval (CI) of the absolute risk difference ranged from -1.94% to +2.87%, therefore the noninferiority was not proven. The same was true for the analysis of protocols. No significant differences between the two treatment methods were found in primary or any of the secondary endpoints. There were also no differences in short-term prevention. The endpoint 'ipsilateral ischemic stroke or vascular death between randomisation and 6 months' occurred in 7.4% of the CAS and 6.5% of the CEA patients (odds ratio 1.16, 95% confidence interval 0.74-1.82). Instent restenoses were significantly more common in the CAS group (4.6% vs 2.2%, odds ratio 2.14, 95% CI 1.10-4.18). Surgery remains the gold standard in treatment of patients with symptomatic carotid artery stenosis. Stent-supported angioplasty can be an alternative only in the hands of an experienced interventionalist with proven low periprocedural complication rate.

  3. Early double J stent removal in renal transplant patients to prevent urinary tract infection - systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Yahav, Dafna; Green, Hefziba; Eliakim-Raz, Noa; Mor, Eytan; Husain, Shahid

    2018-04-01

    Ureteral stents are routinely used in renal transplant and are associated with reduced urological complications but increased urinary tract infections (UTIs). There is no agreement on the preferred time to removal of stents after transplantation. We performed a systematic review and meta-analysis of all randomized controlled trials (RCTs) comparing stent duration of <14 days vs > =14 days. Electronic databases were searched to identify RCTs that compared early vs late stent removal. Primary outcome was urinary tract infections. Secondary outcomes included various urological complications. No significant difference in UTI rates was demonstrated between short and long stent duration (relative risk (RR) 0.85, 95% confidence interval (CI) 0.44-1.64), with significant heterogeneity (I 2  = 86%). Sensitivity analysis evaluating studies with low risk of bias for allocation concealment demonstrated statistically significant lower rates of UTI with short stent duration (RR 0.48, 95% CI 0.32-0.71) with no heterogeneity. No significant difference was demonstrated for the outcome of major urological complications (RR 0.72, 95% CI 0.50-1.05), without heterogeneity. Ureteral stenosis rates were significantly lower in the short duration arm (RR 0.42, 95% CI 0.18-0.98). Early removal of ureteral stents after renal transplant may be associated with reduced rates of UTI and ureteral stenosis. Additional RCTs are needed.

  4. Cardiovascular Research Foundation

    MedlinePlus

    Home About Us The Problem Our Model Leadership Faculty Board of Directors Management Team Advancements Drug-eluting stents TAVR Bioresorbable stents Clinicians and Industry Innovate Skirball Center for Innovation Investigate Clinical Trials Center Educate Center for ...

  5. Colonic stenting as bridge to surgery versus emergency surgery for management of acute left-sided malignant colonic obstruction: a multicenter randomized trial (Stent-in 2 study)

    PubMed Central

    van Hooft, Jeanin E; Bemelman, Willem A; Breumelhof, Ronald; Siersema, Peter D; Kruyt, Philip M; van der Linde, Klaas; Veenendaal, Roeland A; Verhulst, Marie-Louise; Marinelli, Andreas W; Gerritsen, Josephus JGM; van Berkel, Anne-Marie; Timmer, Robin; Grubben, Marina JAL; Scholten, Pieter; Geraedts, Alfons AM; Oldenburg, Bas; Sprangers, Mirjam AG; Bossuyt, Patrick MM; Fockens, Paul

    2007-01-01

    Background Acute left-sided colonic obstruction is most often caused by malignancy and the surgical treatment is associated with a high mortality and morbidity rate. Moreover, these operated patients end up with a temporary or permanent stoma. Initial insertion of an enteral stent to decompress the obstructed colon, allowing for surgery to be performed electively, is gaining popularity. In uncontrolled studies stent placement before elective surgery has been suggested to decrease mortality, morbidity and number of colostomies. However stent perforation can lead to peritoneal tumor spill, changing a potentially curable disease in an incurable one. Therefore it is of paramount importance to compare the outcomes of colonic stenting followed by elective surgery with emergency surgery for the management of acute left-sided malignant colonic obstruction in a randomized multicenter fashion. Methods/design Patients with acute left-sided malignant colonic obstruction eligible for this study will be randomized to either emergency surgery (current standard treatment) or colonic stenting as bridge to elective surgery. Outcome measurements are effectiveness and costs of both strategies. Effectiveness will be evaluated in terms of quality of life, morbidity and mortality. Quality of life will be measured with standardized questionnaires (EORTC QLQ-C30, EORTC QLQ-CR38, EQ-5D and EQ-VAS). Morbidity is defined as every event leading to hospital admission or prolonging hospital stay. Mortality will be analyzed as total mortality as well as procedure-related mortality. The total costs of treatment will be evaluated by counting volumes and calculating unit prices. Including 120 patients on a 1:1 basis will have 80% power to detect an effect size of 0.5 on the EORTC QLQ-C30 global health scale, using a two group t-test with a 0.05 two-sided significance level. Differences in quality of life and morbidity will be analyzed using mixed-models repeated measures analysis of variance. Mortality will be compared using Kaplan-Meier curves and log-rank statistics. Discussion The Stent-in 2 study is a randomized controlled multicenter trial that will provide evidence whether or not colonic stenting as bridge to surgery is to be performed in patients with acute left-sided colonic obstruction. Trial registration Current Controlled Trials ISRCTN46462267. PMID:17608947

  6. The SPIRIT V study: a clinical evaluation of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions.

    PubMed

    Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra

    2011-02-01

    The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice) trials. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    PubMed

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487. © 2017 American Heart Association, Inc.

  8. Long-Term Outcomes of Stenting the Proximal Left Anterior Descending Artery in the PROTECT Trial.

    PubMed

    Roguin, Ariel; Camenzind, Edoardo; Kerner, Arthur; Beyar, Rafael; Boersma, Eric; Mauri, Laura; Steg, Ph Gabriel; Wijns, William

    2017-03-27

    This study sought to compare the outcomes of patients undergoing drug-eluting stent implantation according to lesion location within or outside the proximal left anterior descending (LAD) artery. Proximal LAD artery involvement is considered uniquely in revascularization guidelines. The impact of LAD lesion location on long-term outcomes after revascularization is poorly understood in context of current percutaneous coronary intervention and medical therapy. Among 8,709 patients enrolled in PROTECT (Patient Related Outcomes with Endeavor Versus Cypher Stenting Trial), a multicenter percutaneous coronary intervention trial, we compared the outcomes of 2,534 patients (29.1%) (3,871 lesions [31.5%]) with stents implanted in the proximal LAD to 6,172 patients (70.9%) (8,419 lesions [68.5%]) with stents implanted outside the proximal LAD. At the 4-year follow-up, death rates were the same (5.8% vs. 5.8%; p > 0.999), but more myocardial infarctions occurred in the proximal LAD group (6.2% vs. 4.9%; p = 0.015). The rate of clinically driven target vessel failure (TVF) (14.8% vs. 13.5%; p = 0.109), major adverse cardiac event(s) (MACE) (15.0% vs. 13.7%; hazard ratio: 1.1; 95% confidence interval: 0.97 to 1.31; p = 0.139), and stent thrombosis (2.1% vs. 2.0%; p = 0.800) were similar. Drug-eluting stent type had no interaction with MACE or TVF. In multivariate analysis, the proximal LAD was a predictor of myocardial infarction (p = 0.038) but not of TVF (p = 0.149) or MACE (p = 0.069). In this study of contemporary percutaneous coronary intervention, proximal LAD location was associated with higher rates of myocardial infarction during the long-term follow-up, but there were no differences in stent thrombosis, death, TVF, or overall MACE. This finding may suggest that, in the drug-eluting stent era, proximal LAD no longer confers a different prognosis than other lesion sites. (Randomized Study Comparing Endeavor With Cypher Stents [PROTECT]; NCT00476957). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. The STENTYS self-apposing stent technology in coronary artery disease: literature review and future directions.

    PubMed

    Lu, Huangling; de Winter, Robbert J; Koch, Karel T

    2018-06-21

    Coronary stent designs have been through extensive developments in the past few decades. Since the first introduction of the self-apposing STENTYS stent, several theoretical advantages of its nitinol platform have been clinically evaluated. This paper reviews the current status, ongoing work and future directions of this device. Areas covered: The OPEN (STENTYS Coronary Bifurcation Stent System fOr the PErcutaNeous treatment of de novo lesions in native bifurcated coronary arteries) trials revealed high technical success rates of the STENTYS performance in bifurcation lesions. The APPOSITION (Assessment of the Safety and Performance of the STENTYS self-expanding Coronary Stent in Acute Myocardial Infarction) trials demonstrated the safety and feasibility of the device in patients with acute myocardial infarction. Optical coherence tomography showed better short-term strut apposition in patients treated with the STENTYS stent in APPOSITION IV. The clinical outcomes of the device in saphenous vein graft lesions and left main coronary artery disease are favourable. Expert Commentary: Despite numerous theoretical advantages of the nitinol platform, superiority of the STENTYS self-apposing stent over currently available DES has not yet been proven. However, the ongoing registries evaluating the performance of the STENTYS Xposition will provide more insights in its clinical performance.

  10. Thirty-Day Outcome of a Multicenter Registry Study of Stenting for Symptomatic Intracranial Artery Stenosis in China.

    PubMed

    Miao, Zhongrong; Zhang, Yong; Shuai, Jie; Jiang, Changchun; Zhu, Qiyi; Chen, Kangning; Liu, Li; Li, Baomin; Shi, Xiangqun; Gao, Lianbo; Liu, Yajie; Wang, Feng; Li, Yongli; Liu, Tieyan; Zheng, Hongbo; Wang, Yilong; Wang, Yongjun

    2015-10-01

    Although recent trials have suggested that stenting is worse than medical therapy for patients with severe symptomatic intracranial atherosclerotic stenosis, it is not clear whether this conclusion applies to a subset of patients with hypoperfusion symptoms. To justify for a new trial in China, we performed a multicenter prospective registry study to evaluate the safety and efficacy of endovascular stenting within 30 days for patients with severe symptomatic intracranial atherosclerotic stenosis. Patients with symptomatic intracranial atherosclerotic stenosis caused by 70% to 99% stenosis combined with poor collaterals were enrolled. The patients were treated either with balloon-mounted stent or with balloon predilation plus self-expanding stent as determined by the operators following a guideline. The primary outcome within 30 days is stroke, transient ischemic attack, and death after stenting. The secondary outcome is successful revascularization. The baseline characteristics and outcomes of the 2 treatment groups were compared. From September 2013 to January 2015, among 354 consecutive patients, 300 patients (aged 58.3±9.78 years) were recruited, including 159 patients treated with balloon-mounted stent and 141 patients with balloon plus self-expanding stent. The 30-day rate of stroke, transient ischemic attack, and death was 4.3%. Successful revascularization was 97.3%. Patients treated with balloon-mounted stent were older, less likely to have middle cerebral artery lesions, more likely to have vertebral artery lesions, more likely to have Mori A lesions, less likely to have Mori C lesions, and likely to have lower degree of residual stenosis than patients treated with balloon plus self-expanding stent. The short-term safety and efficacy of endovascular stenting for patients with severe symptomatic intracranial atherosclerotic stenosis in China is acceptable. Balloon-mounted stent may have lower degree of residual stenosis than self-expanding stent. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01968122. © 2015 American Heart Association, Inc.

  11. Biodegradable stents for the treatment of refractory or recurrent benign esophageal stenosis.

    PubMed

    Imaz-Iglesia, Iñaki; García-Pérez, Sonia; Nachtnebel, Anna; Martín-Águeda, Belén; Sánchez-Piedra, Carlos; Karadayi, Bilgehan; Demirbaş, Ali Rıza

    2016-06-01

    Esophageal stents are used for the treatment of refractory and recurrent dyphagias. In 2007, esophageal biodegradable stents (EBS) were authorised as an alternative to existing metal and plastic stents in Europe. The advantages claimed for EBS are fewer complications concerning tissue ingrowth, stent migration and stent removal. We performed a systematic review to evaluate the efficacy and safety of EBS compared to fully-covered self-expanding metal stents, self-expanding plastic stents, and esophageal dilation for the treatment of refractory or recurrent benign esophageal stenosis. Three comparative studies (one randomized controlled trial and two cohort studies) were assessed. The studies used different inclusion criteria, had a very small (sample) size and the quality of the evidence was very low. Expert commentary: The current evidence is insufficient to determine the relative efficacy or safety of esophageal biodegradable stents. The results of this systematic review should be updated once new evidence is available.

  12. Cost effectiveness of drug-eluting stents as compared with bare metal stents in patients with coronary artery disease.

    PubMed

    Wisløff, Torbjørn; Atar, Dan; Sønbø Kristiansen, Ivar

    2013-01-01

    The aim of this study was to estimate the incremental cost effectiveness of replacing bare metal stents (BMS) by drug-eluting stents (DES) when using trial data and registry data. We developed a Markov model (model of cost effectiveness of coronary artery disease) in which 60-year-old patients started by undergoing percutaneous coronary intervention for acute or subacute coronary artery disease. The patients are followed until death or 100 years of age. Data on the occurrence of events (revascularization, acute myocardial infarction, and death) were based on Scandinavian registry data. Separate analyses were conducted with data on effectiveness based on randomized controlled trials and patient registries. On using trial data, it was found that sirolimus-eluting stents (SES) yield 0.003 greater life expectancy and $3300 lower costs than do BMS (dominant strategy). Paclitaxel-eluting stents (PES) yield 0.148 more life years than do SES at additional lifetime costs of $2800 ($21,400 per life year gained). On using registry data, the cost per life year gained was found to be $4900 when replacing BMS with DES. Probabilistic sensitivity analyses, on the other hand, indicate that PES only has a 50%-75% probability of being cost effective, regardless of the type of effectiveness data. DESs are cost effective with current willingness to pay for life year gains. Whether PES or SES is the most effective DES remains uncertain.

  13. Spectral Imaging for Intracranial Stents and Stent Lumen.

    PubMed

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P < .05) and showed the highest mean grading score (2.94 ± 0.94; P < .05) and contrast/noise ratio of in-stent lumen (160.03 ±37.79; P < .05) among all the modes. Iodine (water) images can help reduce stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  14. Plastic biliary stent patency in patients with locally advanced pancreatic adenocarcinoma receiving downstaging chemotherapy.

    PubMed

    Ge, Phillip S; Hamerski, Christopher M; Watson, Rabindra R; Komanduri, Srinadh; Cinnor, Birtukan B; Bidari, Kiran; Klapman, Jason B; Lin, Cui L; Shah, Janak N; Wani, Sachin; Donahue, Timothy R; Muthusamy, V Raman

    2015-02-01

    Plastic stents in patients with biliary obstruction caused by pancreatic adenocarcinoma are typically exchanged at 3-month intervals. Plastic stents may have reduced durability in patients receiving chemotherapy. To determine the duration of plastic biliary stent patency in patients undergoing chemotherapy for pancreatic adenocarcinoma. Retrospective, multicenter cohort study. Three tertiary academic referral centers. A total of 173 patients receiving downstaging chemotherapy for locally advanced or borderline resectable pancreatic adenocarcinoma from 1996 to 2013. Placement of 10F or larger plastic biliary stents. Primary outcome was overall duration of stent patency. Secondary outcomes included the incidence of premature stent exchange (because of cholangitis or jaundice) and hospitalization rates. A total of 233 plastic stents were placed, and the overall median duration of stent patency was 53 days (interquartile range [IQR] 25-99 days). Eighty-seven stents were removed at the time of surgical resection, and 63 stents were exchanged routinely per protocol. The remaining 83 stent exchanges were performed for worsening liver function test results, jaundice, or cholangitis, representing a 35.6% rate of premature stent exchange. The median stent patency duration in the premature stent exchange group was 49 days (IQR 25-91 days) with a 44.6% hospitalization rate. The overall rate of cholangitis was 15.0% of stent exchanges, occurring a median of 56 days after stent placement (IQR 26-89 days). Retrospective study. Plastic biliary stents placed during chemotherapy/chemoradiation for pancreatic adenocarcinoma have a shorter-than-expected patency duration, and a substantial number of patients will require premature stent exchange. Consideration should be given to shortening the interval for plastic biliary stent exchange. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Early Ventricular Tachycardia or Fibrillation in Patients With ST Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention and Impact on Mortality and Stent Thrombosis (from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction Trial).

    PubMed

    Kosmidou, Ioanna; Embacher, Monica; McAndrew, Thomas; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W

    2017-11-15

    The prevalence and impact of early ventricular arrhythmias (ventricular tachycardia [VT]/ventricular fibrillation [VF]) occurring before mechanical revascularization for acute ST segment elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention are poorly understood. We sought to investigate the association between early VT/VF and long-term clinical outcomes using data from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial. Among 3,602 patients with STEMI, 108 patients (3.0%) had early VT/VF. Baseline clinical characteristics were similar in patients with versus without early VT/VF. Patients with early VT/VF had shorter symptom-to-balloon times and lower left ventricular ejection fraction and underwent more frequent thrombectomy compared with patients without early VT/VF. Adjusted 3-year rates of all-cause death (15.7% vs 6.5%; adjusted hazard ratio 2.62, 95% confidence interval 1.48 to 4.61, p <0.001) and stent thrombosis (13.7% vs 5.7%; adjusted hazard ratio 2.74, 95% confidence interval 1.52 to 4.93, p <0.001) were significantly higher in patients with early VT/VF compared with patients without early VT/VF. In conclusion, in the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial, VT/VF occurring before coronary angiography and revascularization in patients with STEMI was strongly associated with increased 3-year rates of death and stent thrombosis. Further investigation into the mechanisms underlying the increased risk of early stent thrombosis in patients with early VT/VF is required. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy.

    PubMed

    Lee, Byoung-Kwon; Kim, Jung-Sun; Lee, Oh-Huyn; Min, Pil-Ki; Yoon, Young-Won; Hong, Bum-Kee; Shin, Dong-Ho; Kang, Tae-Soo; Kim, Byung Ok; Cho, Duk-Kyu; Jeon, Dong Woon; Woo, Sung-Ill; Choi, Seonghoon; Kim, Yong Hoon; Kang, Woong-Chol; Kim, Seunghwan; Kim, Byeong-Keuk; Hong, Myeong-Ki; Jang, Yangsoo; Kwon, Hyuck Moon

    2018-03-20

    There are few randomised studies concerning the optimal duration of dual antiplatelet therapy (DAPT) for patients who receive a second-generation drug-eluting stent (DES). This trial aimed to investigate the safety of six-month compared with 12-month DAPT maintenance after second-generation DES implantation. A prospective, randomised, multicentre trial was performed at 10 medical centres. The 1,368 patients included in the study received a biolimus-eluting stent (BES) or a zotarolimus-eluting stent (ZES). The primary outcome measured was the composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), or ischaemia-driven target lesion revascularisation at the 12-month follow-up. The secondary outcome was the percentage of uncovered struts at six months in 60 patients (30 ZES, 30 BES) using optical coherence tomography (OCT) assessment. Each patient was randomly assigned to six-month (n=684) or 12-month DAPT (n=684). Major adverse cardiac events at 12 months occurred in eight patients (1.2%) in the six-month DAPT group and in four patients (0.6%) in the 12-month DAPT group (risk difference 0.6%; 95% confidence interval [CI]: -0.4-1.6%; p=0.24). The upper 95% CI limit was lower than the pre-specified limit of 4% non-inferiority (p for non-inferiority <0.05). The percentage of uncovered struts was 3.16±4.30% at six months in 60 stents of 60 patients. After second-generation DES implantation, six-month DAPT was not inferior to 12-month DAPT in terms of MACE occurrence over the 12-month follow-up period. OCT examination revealed favourable stent strut coverage at six months after stent implantation.

  17. A review on biodegradable materials for cardiovascular stent application

    NASA Astrophysics Data System (ADS)

    Hou, Li-Da; Li, Zhen; Pan, Yu; Sabir, MuhammadIqbal; Zheng, Yu-Feng; Li, Li

    2016-09-01

    A stent is a medical device designed to serve as a temporary or permanent internal scaffold to maintain or increase the lumen of a body conduit. The researchers and engineers diverted to investigate biodegradable materials due to the limitation of metallic materials in stent application such as stent restenosis which requires prolonged anti platelet therapy, often result in smaller lumen after implantation and obstruct re-stenting treatments. Biomedical implants with temporary function for the vascular intervention are extensively studied in recent years. The rationale for biodegradable stent is to provide the support for the vessel in predicted period of time and then degrading into biocompatible constituent. The degradation of stent makes the re-stenting possible after several months and also ameliorates the vessel wall quality. The present article focuses on the biodegradable materials for the cardiovascular stent. The objective of this review is to describe the possible biodegradable materials for stent and their properties such as design criteria, degradation behavior, drawbacks and advantages with their recent clinical and preclinical trials.

  18. Scanning Electron Microscopic Features of Nasolacrimal Silastic Stents Retained for Prolong Durations Following Dacryocystorhinostomy.

    PubMed

    Ali, Mohammad Javed; Baig, Farhana; Lakshman, Mekala; Naik, Milind N

    2016-01-01

    The aims of this study were to examine the scanning electron microscopic features of silastic nasolacrimal duct stents retained for long durations following a dacryocystorhinostomy. A prospective interventional study was performed on stents retrieved from patients who were lost to follow up after a dacryocystorhinostomy with Crawford stent insertion. Long duration was defined as stents retrieved at a minimum of 1 year following a dacryocystorhinostomy. None of the patients had any evidence of postoperative infection. After removal, the stent segments were subjected to biofilm and physical deposit analysis using standard protocols of scanning electron microscopy. These stent segments were compared against sterile stents which acted as controls. A total of 7 stents were studied. Five were consecutive patient samples, and 2 were sterile stents. All the 5 stents were retrieved from patients who were lost to follow up for a minimum of 12 months following surgery. The mean duration of intubation at retrieval was 21 months. All the stents demonstrated evidence of biofilm formation and physical deposits. However, as the duration of retention increased, the deposits and biofilms were noted to be progressively denser, multilayered and extensive. Certain areas demonstrated thick biofilm integration with the deposits. Polymicrobial communities were noted within the exopolysaccharide matrix. This is the first study to exclusively report on scanning electron microscopic features of lacrimal stents retained for long durations. Further studies on physical elements within the deposits and protein analysis would provide more insights into stent-tissue interactions.

  19. A prospective randomized study for efficacy of an uncovered double bare metal stent compared to a single bare metal stent in malignant biliary obstruction.

    PubMed

    Lee, Hyun Jik; Chung, Moon Jae; Park, Jeong Yup; Park, Seung Woo; Nam, Chung Mo; Song, Si Young; Bang, Seungmin

    2017-08-01

    A biliary self-expandable metal stent (SEMS) is commonly used to relieve malignant biliary obstruction. The aim of this study was to compare the efficacy of a conventional uncovered SEMS with that of a newly developed uncovered double bare metal stent in reducing the risk of stent occlusion caused by tumor ingrowth. We performed a prospective, open-labeled, randomized trial in 71 patients at Severance Hospital, Yonsei University College of Medicine from June 2013 to June 2014. Patients with inoperable malignant biliary obstruction were included and randomized to receive an uncovered single bare metal stent (SBSs; S&G Biotech Inc.), an uncovered single bare metal stent (SBSt; Taewoong Medical), or an uncovered double bare metal stent (DBS; S&G Biotech Inc.). The mean age was 66.6 years (range, 35-83), and 42 (59.2%) were male. The mean duration of stent patency was 212 days (±152) in the DBS group (n = 24) compared with 124 days (±98) in the SBSs group (n = 23; P = 0.022 for noninferiority) and 116 days (±79) in the SBSt group (n = 24; P = 0.010 for noninferiority). There were no differences in the incidences of early and delayed complications or migration. The newly developed DBS is noninferior to the conventional uncovered SEMSs on duration of stent patency and tumor ingrowth occurred less frequently in the DBS group. This might decrease the need for reintervention and offer a better quality of life. The trial is registered with Clinicaltrials.gov no: NCT01869894.

  20. Cost-utility analysis of stenting versus endarterectomy in the International Carotid Stenting Study.

    PubMed

    Morris, Stephen; Patel, Nishma V; Dobson, Joanna; Featherstone, Roland L; Richards, Toby; Luengo-Fernandez, Ramon; Rothwell, Peter M; Brown, Martin M

    2016-06-01

    The International Carotid Stenting Study was a multicenter randomized trial in which patients with symptomatic carotid artery stenosis were randomly allocated to treatment by carotid stenting or endarterectomy. Economic evidence comparing these treatments is limited and inconsistent. We compared the cost-effectiveness of stenting versus endarterectomy using International Carotid Stenting Study data. We performed a cost-utility analysis estimating mean costs and quality-adjusted life years per patient for both treatments over a five-year time horizon based on resource use data and utility values collected in the trial. Costs of managing stroke events were estimated using individual patient data from a UK population-based study (Oxford Vascular Study). Mean costs per patient (95% CI) were US$10,477 ($9669 to $11,285) in the stenting group (N = 853) and $9669 ($8835 to $10,504) in the endarterectomy group (N = 857). There were no differences in mean quality-adjusted life years per patient (3.247 (3.160 to 3.333) and 3.228 (3.150 to 3.306), respectively). There were no differences in adjusted costs between groups (mean incremental costs for stenting versus endarterectomy $736 (95% CI -$353 to $1826)) or adjusted outcomes (mean quality-adjusted life years gained -0.010 (95% CI -0.117 to 0.097)). The incremental net monetary benefit for stenting versus endarterectomy was not significantly different from zero at the maximum willingness to pay for a quality-adjusted life year commonly used in the UK. Sensitivity analyses showed little uncertainty in these findings. Economic considerations should not affect whether patients with symptomatic carotid stenosis undergo stenting or endarterectomy. © 2016 World Stroke Organization.

  1. Randomized comparison of Zotarolimus-Eluting Endeavor Sprint versus bare-metal stent implantation in uncertain drug-eluting stent candidates: rationale, design, and characterization of the patient population for the Zotarolimus-eluting Endeavor Sprint stent in uncertain DES candidates study.

    PubMed

    Valgimigli, Marco; Patialiakas, Athanasios; Thury, Attila; Colangelo, Salvatore; Campo, Gianluca; Tebaldi, Matteo; Ungi, Imre; Tondi, Stefano; Roffi, Marco; Menozzi, Alberto; de Cesare, Nicoletta; Garbo, Roberto; Meliga, Emanuele; Testa, Luca; Gabriel, Henrique M; Airoldi, Flavio; Ferlini, Marco; Liistro, Francesco; Dellavalle, Antonio; Vranckx, Pascal; Briguori, Carlo

    2013-11-01

    The use of drug-eluting stent (DES) instead of bare-metal stent (BMS) in patients at high stent thrombosis or bleeding risk as well as in those at low restenosis risk (ie, uncertain DES candidates) remains a matter of debate. Zotarolimus-Eluting Endeavor Sprint stent (E-ZES) (Santa Rosa, CA) is a hydrophilic polymer-based second-generation device with unique drug fast-release profile, which may allow for a shorter dual antiplatelet therapy (DAPT) duration without safety concerns. The primary objective is to assess whether E-ZES implantation followed by a shorter than currently recommended course of DAPT will decrease the incidence of 12-month major adverse cardiovascular events as compared with BMS in undefined DES recipients. Actual duration of DAPT regimen will be dictated by patients' characteristics and not by stent type and, as such, can be as short as 30 days after intervention in both stent groups. The ZEUS study is an open-label randomized clinical trial conducted at 20 clinical sites in Italy, Switzerland, Portugal, and Hungary. With 1,600 individuals, this study will have 85% power to detect a 33% difference in the primary end point consisting of the composite of death, nonfatal myocardial infarction, or target vessel revascularization. The ZEUS trial aims to assess whether the use of E-ZES, followed by a DAPT duration regimen based on patients' characteristics and not by stent type, is superior to conventional BMS implantation in undefined DES recipients who qualify for the presence of high thrombosis, bleeding, or low restenosis risk criteria. © 2013.

  2. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    PubMed

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Newest-generation drug-eluting and bare-metal stents combined with prasugrel-based antiplatelet therapy in large coronary arteries: the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination part II (BASKET-PROVE II) trial design.

    PubMed

    Jeger, Raban; Pfisterer, Matthias; Alber, Hannes; Eberli, Franz; Galatius, Søren; Naber, Christoph; Pedrazzini, Giovanni; Rickli, Hans; Jensen, Jan Skov; Vuilliomenet, André; Gilgen, Nicole; Kaiser, Christoph

    2012-02-01

    In the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination (BASKET-PROVE), drug-eluting stents (DESs) had similar 2-year rates of death and myocardial infarction but lower rates of target vessel revascularization and major adverse cardiac events compared with bare-metal stents (BMSs). However, comparative clinical effects of newest-generation DES with biodegradable polymers vs second-generation DES or newest-generation BMS with biocompatible coatings, all combined with a prasugrel-based antiplatelet therapy, on 2-year outcomes are not known. In BASKET-PROVE II, 2,400 patients with de novo lesions in native vessels ≥3 mm in diameter are randomized 1:1:1 to receive a conventional DES, a DES with a biodegradable polymer, or a BMS with biocompatible coating. In addition to aspirin, stable patients with BMS will receive prasugrel for 1 month, whereas all others will receive prasugrel for 12 months. The primary end point will be combined cardiac death, nonfatal myocardial infarction, and target vessel revascularization up to 2 years. Secondary end points include stent thrombosis and major bleeding. The primary aim is to test (1) the noninferiority of a biodegradable-polymer DES to a conventional DES and (2) the superiority of both DESs to BMS. A secondary aim is to compare the outcomes with those of BASKET-PROVE regarding the effects of prasugrel-based vs clopidogrel-based antiplatelet therapy. By the end of 2010, 878 patients (37% of those planned) were enrolled. This study will test the comparative long-term safety and efficacy of newest-generation stents on the background of contemporary antiplatelet therapy in a large all-comer population undergoing large native coronary artery stenting. Copyright © 2012 Mosby, Inc. All rights reserved.

  4. Improved outcomes of elderly patients treated with drug-eluting versus bare metal stents in large coronary arteries: results from the BAsel Stent Kosten-Effektivitäts Trial PROspective Validation Examination randomized trial.

    PubMed

    Kurz, David J; Bernheim, Alain M; Tüller, David; Zbinden, Rainer; Jeger, Raban; Kaiser, Christoph; Galatius, Soeren; Hansen, Kim W; Alber, Hannes; Pfisterer, Matthias; Eberli, Franz R

    2015-10-01

    Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available. Planned secondary analysis of patients ≥75 years recruited to the "BASKET-PROVE" trial, in which 2,314 patients undergoing percutaneous coronary intervention for large (≥3.0 mm) native vessel disease were randomized 2:1 to DES (everolimus- vs sirolimus-eluting stents 1:1) versus BMS. All patients received 12 months of dual antiplatelet therapy. The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years. Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates of nonfatal myocardial infarction (1.2% vs 5.5%, hazard ration (HR) 0.44 [0.21-0.83]; P = .009), all-cause death (7.4% vs 14.4%; HR 0.7 [0.51-0.95]; P = .02), and target vessel revascularization (TVR) (2.3% vs 6.2%; HR 0.59 [0.34-0.99]; P = .046) were also lower, whereas stent thrombosis and bleeding rates were similar. In contrast, among patients <75 years (n = 1,909), the only significant benefit of DES was a reduced rate of TVR (4.0% vs 8.7%, HR 0.66 [0.55-0.80]; P < .0001). In patients ≥75 years requiring large (≥3.0 mm) coronary stents, use of DES was beneficial compared with BMS and reduced the rate of ischemic events, mortality, and TVR. These data suggest that DES should be preferred over BMS in elderly patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. High dose-rate brachytherapy for the treatment of lower extremity in-stent restenosis.

    PubMed

    Ho, Karen J; Devlin, Phillip M; Madenci, Arin L; Semel, Marcus E; Gravereaux, Edwin C; Nguyen, Louis L; Belkin, Michael; Menard, Matthew T

    2017-03-01

    Historically, edge stenosis and late thrombosis limited the effectiveness of adjunctive endovascular brachytherapy (EVBT) for in-stent restenosis (ISR) after percutaneous transluminal angioplasty (PTA) and stenting. We evaluated an updated protocol of PTA and EVBT for ISR among patients with lower extremity occlusive disease. This is a retrospective, single-center review of patients treated with PTA and EVBT for ISR in the iliac and femoropopliteal segments between 2004 and 2012. A dose of 20 Gy was given at a depth of 0.5 mm beyond the radius of the largest PTA balloon using iridium 192, with at least 2-cm-long margins of radiation coverage proximal and distal to the injured area. Stents were assessed for patency by duplex ultrasound imaging at 1, 3, 6, 9, 12, and 18 months and then yearly. The primary end point was freedom from ≥50% restenosis in the treated segment at 6 months, 1 year, and 2 years. Patency data were estimated using the Kaplan-Meier method. Secondary end points were early and late thrombotic occlusion. Among 42 consecutive cases in 35 patients of EVBT for ISR in common or external iliac (9 [20.8%]) and superficial femoral or popliteal (33 [76.7%]) arteries, or both, 21 patients (50%) had claudication, asymptomatic hemodynamically significant stenoses were identified on duplex ultrasound imaging in 16 (38.1%), and 4 (9.8%) had critical limb ischemia. Mean treated length was 23.5 ± 12.3 cm over a mean duration of 16.1 ± 9.6 minutes. There was one technical failure (2.3%). Median post-EVBT follow-up time was 682 days (range, 1-2262 days). There were two (4.9%) and five (11.9%) cases of early and late thrombotic occlusions, respectively. There was one death, believed to be secondary to acute coronary syndrome. Primary, assisted primary, and secondary patency in the entire cohort was 75.2%, 89.1%, and 89.1%, respectively, at 1 year and 63.7%, 80.6%, and 85.6%, respectively, at 2 years. This contemporary protocol of PTA and adjunctive EVBT for lower extremity ISR, which is updated from those used in prior trials and includes a surveillance strategy that identifies at-risk stents for reintervention before occlusion, may be a promising treatment for lower extremity ISR at institutions where a close collaboration between vascular surgeons and radiation oncologists is feasible. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  6. Design of the Revascularization With Open Bypass vs Angioplasty and Stenting of the Lower Extremity Trial (ROBUST): a randomized clinical trial.

    PubMed

    Malas, Mahmoud B; Qazi, Umair; Glebova, Natalia; Arhuidese, Isibor; Reifsnyder, Thomas; Black, James; Perler, Bruce A; Freischlag, Julie A

    2014-12-01

    To our knowledge, there is no level 1 evidence comparing open bypass with angioplasty and stenting in TransAtlantic Inter-Society Consensus (TASC II) B and C superficial femoral artery lesions. The Revascularization With Open Bypass vs Angioplasty and Stenting of the Lower Extremity Trial (ROBUST) is the first prospective randomized clinical trial comparing both treatments. To report the design of the ROBUST trial. The primary aim of the trial is to compare (1) the patency rate (primary, primary assisted, and secondary patency at 6 and 12 months), (2) improvement of quality of life, (3) clinical improvement (at least 1 Rutherford category), and (4) wound healing and limb salvage in patients presenting with critical limb ischemia; secondary aims include (1) cost-effectiveness by factoring procedure and hospital admission costs including rehabilitation, readmission, and reintervention costs, (2) amputation-free survival, (3) reintervention rate, and (4) 30-day operative mortality, morbidity, and wound and access complications. ROBUST is a prospective randomized clinical trial with the aim to enroll 320 patients with intermittent claudication that does not respond to medical management and patients with critical limb ischemia. The maximum level of medical therapy will be administered using antiplatelet agents and statins, as well as measures to control hypertension and diabetes mellitus. Patients with TASC II B or C lesions are prospectively randomized to receive either femoropopliteal bypass or percutaneous transluminal angioplasty and stenting; patients with TASC II A and D lesions are not randomized and receive percutaneous transluminal angioplasty and stenting or femoropopliteal bypass, respectively. All patients will be evaluated at 1, 6, and 12 months postoperatively with physical examination, ankle brachial index, duplex, and a quality-of-life questionnaire. The trial is actively enrolling participants. At the time of writing, 29 patients have been enrolled; most are male (60%) and white (65%). Providing level 1 evidence, ROBUST may help to establish guidelines for the treatment of superficial femoral artery lesions, eliminate unnecessary procedures, and reduce health care costs. clinicaltrials.gov Identifier: NCT01602159.

  7. What's new in stroke? The top 10 studies of 2009-2011: part II.

    PubMed

    Hart, Robert G; Oczkowski, Wiesław J

    2011-06-01

    Five studies published between 2009 and 2011 are reviewed that importantly inform stroke prevention for patients with atrial fibrillation (AF) or with cervical carotid artery stenosis. Two large, phase III randomized trials tested novel oral anticoagulants for stroke prevention in patients with AF: the direct thrombin inhibitor dabigatran 150 mg twice daily was superior to adjusted-dose warfarin (RE-LY trial) and the direct factor Xa inhibitor apixaban was far superior to aspirin in patients deemed unsuitable for warfarin (AVERROES trial). For both novel anticoagulants, major bleeding rates were similar to the comparator treatment. Clopidogrel plus aspirin was more efficacious than aspirin alone for prevention of stroke in patients with AF deemed unsuitable for warfarin, but major bleeding was significantly increased with dual antiplatelet therapy (ACTIVE A trial). Two large randomized trials (CREST, ICSS) provide the best available data on the short-term risks of carotid artery stenting vs. endarterectomy. In both trials, periprocedural stroke was more frequent with stenting than with endarterectomy, but the increased risk was largely confined to patients >70 years old. For younger patients, periprocedural risks were comparable with stenting or endarterectomy, but long-term outcomes are required to assess the relative merits of the two procedures.

  8. Airway bypass treatment of severe homogeneous emphysema: taking advantage of collateral ventilation.

    PubMed

    Choong, Cliff K; Cardoso, Paulo F G; Sybrecht, Gerhard W; Cooper, Joel D

    2009-05-01

    Airway bypass is being investigated as a new form of minimally invasive therapy for the treatment of homogeneous emphysema. It is a bronchoscopic catheter-based procedure that creates transbronchial extra-anatomic passages at the bronchial segmental level. The passages are expanded, supported with the expectation that the patency is maintained by paclitaxel drug-eluting airway bypass stents. The concept of airway bypass has been demonstrated in two separate experimental studies. These studies have shown that airway bypass takes advantage of collateral ventilation present in homogeneous emphysema to allow trapped gas to escape and reduce hyperinflation. It improves lung mechanics, expiratory flow, and volume. Airway bypass stent placements have been shown to be feasible and safe in both animal and human studies. Paclitaxel-eluting airway bypass stents were found to prolong stent patency and were adopted for clinical studies. A study evaluating the early results of the clinical application of airway bypass with paclitaxel-eluting stents found that airway bypass procedures reduced hyperinflation and improved pulmonary function and dyspnea in selected subjects who have severe emphysema. The duration of benefit appeared to correlate with the degree of pretreatment hyperinflation. These preliminary clinical results supported further evaluation of the procedure and led to the EASE Trial. The EASE Trial is a prospective, multicenter, randomized, double-blind, sham-controlled study. The trial aims to evaluate the safety and effectiveness of the airway bypass to improve pulmonary function and reduce dyspnea in homogeneous emphysema subjects who have severe hyperinflation. The trial is presently ongoing worldwide, though enrollment was completed.

  9. Comparison of 3 biodegradable polymer and durable polymer-based drug-eluting stents in all-comers (BIO-RESORT): rationale and study design of the randomized TWENTE III multicenter trial.

    PubMed

    Lam, Ming Kai; Sen, Hanim; Tandjung, Kenneth; van Houwelingen, K Gert; de Vries, Arie G; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; Löwik, Marije M; Linssen, Gerard C M; Ijzerman, Maarten J; van der Palen, Job; Doggen, Carine J M; von Birgelen, Clemens

    2014-04-01

    To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome. Copyright © 2014 The Authors. Published by Mosby, Inc. All rights reserved.

  10. Effect of mobile phone reminder messages on adherence of stent removal or exchange in patients with benign pancreaticobiliary diseases: a prospectively randomized, controlled study.

    PubMed

    Gu, Yong; Wang, Limei; Zhao, Lina; Liu, Zhiguo; Luo, Hui; Tao, Qin; Zhang, Rongchun; He, Shuixiang; Wang, Xiangping; Huang, Rui; Zhang, Linhui; Pan, Yanglin; Guo, Xuegang

    2016-08-26

    Plastic and covered metal stents need to be removed or exchanged within appropriate time in case of undesirable complications. However, it is not uncommon that patients do not follow the recommendation for further stent management after Endoscopic Retrograde Cholangiopancreatography (ERCP). The effect of short message service (SMS) intervention monthly on the stent removal/exchange adherence in patients after ERCP is unknown at this time. A prospective, randomized controlled study was conducted. After receiving regular instructions, patients were randomly assigned to receive SMS reminding monthly (SMS group) for stent removal/exchange or not (control group). The primary outcome was stent removal/exchange adherence within appropriate time (4 months for plastic stent or 7 months for covered stent). Multivariate analysis was performed to assess factors associated with stent removal/exchange adherence within appropriate time. Intention-to-treat analysis was used. A total of 48 patients were randomized, 23 to the SMS group and 25 to the control. Adherence to stent removal/exchange was reported in 78.2 % (18/23) of patients receiving the SMS intervention compared with 40 % (10/25) in the control group (RR 1.98, 95 % CI 1.16-3.31; p = 0 · 010). Among patients with plastic stent insertion, the median interval time from stent implantation to stent removal/exchange were 90 days in the SMS group and 136 days in the control respectively (HR 0.36, 95 % CI 0.16-0.84, p = 0.018). No difference was found between the two groups regarding late-stage stent-related complications. The rate of recurrent abdominal pain tended to be lower in SMS group without significant difference (8.7 vs 28 %, p = 0.144). Multivariate logistic regression analyses revealed that SMS reminding was the only factor associated with adherence of stent removal/exchange (OR 6.73, 95 % CI 1.64-27.54, p = 0.008). This first effectiveness trial demonstrated that SMS reminding monthly could significantly increase the patient adherence to stent removal/exchange after ERCP. The study was respectively registered on July 10 in 2016 at ClinicalTrials.gov ( NCT02831127 ).

  11. Carotid Artery Stenting Trials: Conduct, Results, Critique, and Current Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macdonald, Sumaira, E-mail: sumaira.macdonald@nuth.nhs.uk

    2012-02-15

    The carotid stenting trialists have demonstrated persistence and determination in comparing an evolving technique, carotid artery stenting (CAS), against a mature and exacting standard for carotid revascularisation, carotid endarterectomy (CEA). This review focuses on their endeavours. A total of 12 1-on-1 randomised trials comparing CAS and CEA have been reported; 6 of these can be considered major, and 5 of these reflect (in part) current CAS standards of practice and form the basis of this review. At least 18 meta-analyses seeking to compare CAS and CEA exist. These are limited by the quality and heterogeneity of the data informing themmore » (e.g., five trials were stopped prematurely such that they collectively failed to reach recruitment target by >4000 patients). The Carotid Stenting Trialists' Collaboration Publication represents a prespecified meta-analysis of European trials that were sufficiently similar to allow valid conclusions to be drawn; these trials and conclusions will be explored. When the rate of myocardial infarction (MI) is rigorously assessed, CAS and CEA are equivalent for the composite end point of stroke/death and MI, with more minor strokes for CAS and more MIs for CEA. These outcomes have a discrepant impact on quality of life and subsequent mortality. The all-stroke death outcomes for patients <70 years old are equivalent, with more minor strokes occurring in the elderly during CAS than CEA. There are significantly more severe haematomas and cranial nerve injuries after CEA. The influence of experience on outcome cannot be underestimated.« less

  12. Stent Thrombosis in Drug-Eluting or Bare-Metal Stents in Patients Receiving Dual Antiplatelet Therapy.

    PubMed

    Kereiakes, Dean J; Yeh, Robert W; Massaro, Joseph M; Driscoll-Shempp, Priscilla; Cutlip, Donald E; Steg, P Gabriel; Gershlick, Anthony H; Darius, Harald; Meredith, Ian T; Ormiston, John; Tanguay, Jean-François; Windecker, Stephan; Garratt, Kirk N; Kandzari, David E; Lee, David P; Simon, Daniel I; Iancu, Adrian Corneliu; Trebacz, Jaroslaw; Mauri, Laura

    2015-10-01

    This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p < 0.001). DES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Design of the stenting and aggressive medical management for preventing recurrent stroke in intracranial stenosis trial.

    PubMed

    Chimowitz, Marc I; Lynn, Michael J; Turan, Tanya N; Fiorella, David; Lane, Bethany F; Janis, Scott; Derdeyn, Colin P

    2011-01-01

    Patients with recent transient ischemic attack (TIA) or stroke caused by 70% to 99% stenosis of a major intracranial artery are at high risk of recurrent stroke on usual medical management, suggesting the need for alternative therapies for this disease. The Stenting and Aggressive Medical Management for Preventing Recurrent stroke in Intracranial Stenosis trial is an ongoing, randomized, multicenter, 2-arm trial that will determine whether intracranial angioplasty and stenting adds benefit to aggressive medical management alone for preventing the primary endpoint (any stroke or death within 30 days after enrollment or after any revascularization procedure of the qualifying lesion during follow-up, or stroke in the territory of the symptomatic intracranial artery beyond 30 days) during a mean follow-up of 2 years in patients with recent TIA or stroke caused by 70% to 99% stenosis of a major intracranial artery. Aggressive medical management in both arms consists of aspirin 325 mg per day, clopidogrel 75 mg per day for 90 days after enrollment, intensive risk factor management primarily targeting systolic blood pressure <140 mm Hg (<130 mm Hg in diabetics) and low density cholesterol <70 mg/dL, and a lifestyle modification program. The sample size required to detect a 35% reduction in the rate of the primary endpoint from angioplasty and stenting based on the log-rank test with an alpha of 0.05, 80% power, and adjusting for a 2% loss to follow-up and 5% crossover from the medical to the stenting arm is 382 patients per group. Enrollment began in November 2008 and 451 patients have been enrolled as of March 31, 2011. This is the first randomized stroke prevention trial to compare angioplasty and stenting with medical therapy in patients with intracranial arterial stenosis and to incorporate intensive management of multiple risk factors and a lifestyle modification program in the study design. Hopefully, the results of the trial will lead to more effective therapy for this high-risk disease. Copyright © 2011 National Stroke Association. All rights reserved.

  14. Drug-eluting stents versus bare-metal stents in saphenous vein grafts: a double-blind, randomised trial.

    PubMed

    Brilakis, Emmanouil S; Edson, Robert; Bhatt, Deepak L; Goldman, Steven; Holmes, David R; Rao, Sunil V; Shunk, Kendrick; Rangan, Bavana V; Mavromatis, Kreton; Ramanathan, Kodangudi; Bavry, Anthony A; Garcia, Santiago; Latif, Faisal; Armstrong, Ehrin; Jneid, Hani; Conner, Todd A; Wagner, Todd; Karacsonyi, Judit; Uyeda, Lauren; Ventura, Beverly; Alsleben, Aaron; Lu, Ying; Shih, Mei-Chiung; Banerjee, Subhash

    2018-05-19

    Few studies have examined the efficacy of drug-eluting stents (DES) for reducing aortocoronary saphenous vein bypass graft (SVG) failure compared with bare-metal stents (BMS) in patients undergoing stenting of de-novo SVG lesions. We assessed the risks and benefits of the use of DES versus BMS in de-novo SVG lesions. Patients were recruited to our double-blind, randomised controlled trial from 25 US Department of Veterans Affairs centres. Eligible participants were aged at least 18 years and had at least one significant de-novo SVG lesion (50-99% stenosis of a 2·25-4·5 mm diameter SVG) requiring percutaneous coronary intervention with intent to use embolic protection devices. Enrolled patients were randomly assigned, in a 1:1 ratio, by phone randomisation system to receive a DES or BMS. Randomisation was stratified by presence or absence of diabetes and number of target SVG lesions requiring percutaneous coronary intervention (one or two or more) within each participating site by use of an adaptive scheme intended to balance the two stent type groups on marginal totals for the stratification factors. Patients, referring physicians, study coordinators, and outcome assessors were masked to group allocation. The primary endpoint was the 12-month incidence of target vessel failure, defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularisation. The DIVA trial is registered with ClinicalTrials.gov, number NCT01121224. Between Jan 1, 2012, and Dec 31, 2015, 599 patients were randomly assigned to the stent groups, and the data for 597 patients were used. The patients' mean age was 68·6 (SD 7·6) years, and 595 (>99%) patients were men. The two stent groups were similar for most baseline characteristics. At 12 months, the incidence of target vessel failure was 17% (51 of 292) in the DES group versus 19% (58 of 305) in the BMS group (adjusted hazard ratio 0·92, 95% CI 0·63-1·34, p=0·70). Between-group differences in the components of the primary endpoint, serious adverse events, or stent thrombosis were not significant. Enrolment was stopped before the revised target sample size of 762 patients was reached. In patients undergoing stenting of de-novo SVG lesions, no significant differences in outcomes between those receiving DES and BMS during 12 months of follow-up were found. The study results have important economic implications in countries with high DES prices such as the USA, because they suggest that the lower-cost BMS can be used in SVG lesions without compromising either safety or efficacy. US Department of Veterans Affairs Cooperative Studies Program. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Peri-interventional antibiotic prophylaxis only vs continuous low-dose antibiotic treatment in patients with JJ stents: a prospective randomised trial analysing the effect on urinary tract infections and stent-related symptoms.

    PubMed

    Moltzahn, Felix; Haeni, Katharina; Birkhäuser, Frédéric D; Roth, Beat; Thalmann, George N; Zehnder, Pascal

    2013-02-01

    To evaluate the antibiotic treatment regime in patients with indwelling JJ stents, the benefits and disadvantages of a peri-interventional antibiotic prophylaxis were compared with those of a continuous low-dose antibiotic treatment in a prospective randomised trial. In all, 95 patients were randomised to either receive peri-interventional antibiotic prophylaxis during stent insertion only (group A, 44 patients) or to additionally receive a continuous low-dose antibiotic treatment until stent removal (group B, 51). Evaluations for urinary tract infections (UTI), stent-related symptoms (SRSs) and drug side-effects were performed before stent insertion and consecutively after 1, 2 and 4 weeks and/or at stent withdrawal. All patients received a peri-interventional antibiotic prophylaxis with 1.2 g amoxicillin/clavulanic acid. Amoxicillin/clavulanic acid (625 mg) once daily was administered for continuous low-dose treatment (group B). Primary endpoints were the overall rates of UTIs and SRSs. Secondary endpoints were the rates and severity of drug side-effects. Neither the overall UTI rates (group A: 9% vs group B: 10%), nor the rates of febrile UTIs (group A: 7% vs group B: 6%) were different between the groups. Similarly, SRS rates did not differ (group A: 98% vs group B: 96%). Antibiotic side-effect symptoms were to be increased in patients treated with low-dose antibiotics. A continuous antibiotic low-dose treatment during the entire JJ stent-indwelling time does not reduce the quantity or severity of UTIs and has no effect on SRSs either compared with a peri-interventional antibiotic prophylaxis only. © 2012 BJU International.

  16. Stent-based delivery of adeno-associated viral vectors with sustained vascular transduction and iNOS-mediated inhibition of in-stent restenosis

    PubMed Central

    Fishbein, Ilia; Guerrero, David T.; Alferiev, Ivan S.; Foster, Jonathan B.; Minutolo, Nicholas G.; Chorny, Michael; Mas Monteys, Alejandro; Driesbaugh, Kathryn H.; Nagaswami, Chandrasekaran; Levy, Robert J.

    2017-01-01

    In-stent restenosis remains an important clinical problem in the era of drug eluting stents. Development of clinical gene therapy protocols for the prevention and treatment of in-stent restenosis is hampered by the lack of adequate local delivery systems. Herein we describe a novel stent-based gene delivery platform capable of providing local arterial gene transfer with adeno-associated viral (AAV) vectors. This system exploits the natural affinity of protein G (PrG) to bind to the Fc region of mammalian IgG, making PrG a universal adaptor for surface immobilization of vector-capturing antibodies (Ab). Our results: 1) demonstrate the feasibility of reversible immobilization of AAV2 vectors using vector tethering by AAV2-specific Ab appended to the stent surface through covalently attached PrG, 2) show sustained release kinetics of PrG/Ab-immobilized AAV2 vector particles into simulated physiological medium in vitro and site-specific transduction of cultured cells, 3) provide evidence of long-term (12 weeks) arterial expression of luciferase with PrG/Ab-tethered AAV2Luc, and 4) show anti-proliferative activity and anti-restenotic efficacy of stent-immobilized AAV2iNOS in the rat carotid artery model of stent angioplasty. PMID:28832561

  17. Clopidogrel (Plavix) desensitization: a case series.

    PubMed

    Camara, Miguel G; Almeda, Francis Q

    2005-08-01

    Clopidogrel (Plavix) is a thiopyridine that inhibits the ADP-dependent pathway for platelet activation and has been shown in numerous trials to be effective for a wide variety of patients with cardiovascular disease, particularly those who have undergone coronary stent implantation and who present with acute coronary syndromes. Allergic rashes are one of the common side effects of clopidogrel, which leads to its discontinuation. Type I (Gell and Combs classification) allergic reactions to drugs may be amenable to drug desensitization, allowing safe and prolonged use of the drug. This case series describes a protocol for clopidogrel desensitization over an 8-hr period using 15 doubling doses of clopidogrel given by mouth to achieve a maintenance dose of 75 mg a day. This case series suggests that patients who have had type I drug allergy to clopidogrel may be rapidly desensitized using this protocol. Further studies enrolling a larger number of patients are indicated to confirm the safety and efficacy of this regimen.

  18. Final five-year clinical outcomes in the EVOLVE trial: a randomised evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting stent.

    PubMed

    Meredith, Ian T; Verheye, Stefan; Dubois, Christophe; Dens, Joseph; Farah, Bruno; Carrié, Didier; Walsh, Simon; Oldroyd, Keith; Varenne, Olivier; El-Jack, Seif; Moreno, Raul; Christen, Thomas; Allocco, Dominic J

    2018-04-20

    Long-term data on bioabsorbable polymer-coated everolimus-eluting stents (BP-EES) are limited. The EVOLVE trial compared the safety and efficacy of two dose formulations of the SYNERGY BP-EES with the permanent polymer-coated PROMUS Element EES (PE). The EVOLVE study was a prospective, multicentre, non-inferiority trial that randomised 291 patients with de novo coronary lesions (length: ≤28 mm; diameter: ≥2.25 to ≤3.5 mm) to receive PE (n=98), SYNERGY (n=94), or SYNERGY half-dose (n=99). At five years, there were no significant differences in the rates of TLF or individual components between groups. TLR rates trended lower in both SYNERGY arms than in the PE arm (TLR: 1.1% SYNERGY and 1.0% SYNERGY half-dose vs. 6.1% PE; p=0.07 and p=0.06, respectively). TVR was numerically lower in the SYNERGY arms compared to the PE arm (TVR: 3.3% SYNERGY and 4.2% SYNERGY half-dose vs. 10.2% PE; p=0.06 and p=0.11, respectively). No incidence of stent thrombosis was reported in any arm up to five years. The EVOLVE trial represents the longest-term follow-up of the SYNERGY stent available to date, demonstrating its continued safety and efficacy for the treatment of selected de novo atherosclerotic lesions up to five years.

  19. [Stent-assisted recanalization of femoropopliteal arterial occlusive disease. Influence of stent design on patency rates].

    PubMed

    Treitl, M; Reiser, M F; Treitl, K M

    2016-03-01

    Despite enormous technical progress the results of endovascular treatment of the femoropopliteal vasculature are unsatisfactory and its role is still controversially discussed. In the past decade numerous new stent designs have come onto the market but it is unclear whether they have benefits with respect to patency rates. Comparison of published data on patency rates and target lesion revascularization rates after use of different stent designs in the femoropopliteal vasculature. Analysis of 25 published studies and registries from 2006 to 2015 for classical open-cell stents, interwoven stents and partially or fully covered stents. The published data are heterogeneous and comparative studies for different stent designs are completely missing. Over the past decade the patency rates after femoropopliteal stenting could be improved. According to available data stenting of short lesions < 5 cm does not show any benefit compared to isolated balloon angioplasty. Primary stenting is now recommended for intermediate and longer lesions > 6.4 cm. Due to the heterogeneity of published data a clear benefit for a specific stent design is not obvious; however, data for interwoven stents are promising and show a tendency towards improved patency, at least for certain lesions. Randomized controlled comparative trials are needed to confirm this result.

  20. A cost analysis of stenting in uncomplicated semirigid ureteroscopic stone removal.

    PubMed

    Seklehner, Stephan; Sievert, Karl-Dietrich; Lee, Richard; Engelhardt, Paul F; Riedl, Claus; Kunit, Thomas

    2017-05-01

    To evaluate the outcome and the costs of stenting in uncomplicated semirigid ureteroscopic stone removal. A decision tree model was created to evaluate the economic impact of routine stenting versus non-stenting strategies in uncomplicated ureteroscopy (URS). Probabilities of complications were extracted from twelve randomized controlled trials. Stone removal costs, costs for complication management, and total costs were calculated using Treeage Pro (TreeAge Pro Healthcare version 2015, Software, Inc, Williamstown Massachusetts, USA). Stone removal costs were higher in stented URS (€1512.25 vs. €1681.21, respectively). Complication management costs were higher in non-stented procedures. Both for complications treated conservatively (€189.43 vs. €109.67) and surgically (€49.26 vs. €24.83). When stone removal costs, costs for stent removal, and costs for complication management were considered, uncomplicated URS with stent placement yielded an overall cost per patient of €1889.15 compared to €1750.94 without stent placement. The incremental costs of stented URS were €138.25 per procedure. Semirigid URS with stent placement leads to higher direct procedural costs. Costs for managing URS-related complications are higher in non-stented procedures. Overall, a standard strategy of deferring routine stenting uncomplicated ureteroscopic stone removal is more cost efficient.

  1. Self‐expanding stent effects on radiation dosimetry in esophageal cancer

    PubMed Central

    Francis, Samual R.; Wang, Brian; Williams, Greg V.; Cox, Kristen; Adler, Douglas G.; Shrieve, Dennis C.; Salter, Bill J.

    2013-01-01

    It is the purpose of this study to evaluate how self‐expanding stents (SESs) affect esophageal cancer radiation planning target volumes (PTVs) and dose delivered to surrounding organs at risk (OARs). Ten patients were evaluated, for whom a SES was placed before radiation. A computed tomography (CT) scan obtained before stent placement was fused to the post‐stent CT simulation scan. Three methods were used to represent pre‐stent PTVs: 1) image fusion (IF), 2) volume approximation (VA), and 3) diameter approximation (DA). PTVs and OARs were contoured per RTOG 1010 protocol using Eclipse Treatment Planning software. Post‐stent dosimetry for each patient was compared to approximated pre‐stent dosimetry. For each of the three pre‐stent approximations (IF, VA, and DA), the mean lung and liver doses and the estimated percentages of lung volumes receiving 5 Gy, 10 Gy, 20 Gy, and 30 Gy, and heart volumes receiving 40 Gy were significantly lower (p‐values <0.02) than those estimated in the post‐stent treatment plans. The lung V5, lung V10, and heart V40 constraints were achieved more often using our pre‐stent approximations. Esophageal SES placement increases the dose delivered to the lungs, heart, and liver. This may have clinical importance, especially when the dose‐volume constraints are near the recommended thresholds, as was the case for lung V5, lung V10, and heart V40. While stents have established benefits for treating patients with significant dysphagia, physicians considering stent placement and radiation therapy must realize the effects stents can have on the dosimetry. PACS number: 87.55.dk PMID:23835387

  2. Self-expanding stent effects on radiation dosimetry in esophageal cancer.

    PubMed

    Francis, Samual R; Anker, Christopher J; Wang, Brian; Williams, Greg V; Cox, Kristen; Adler, Douglas G; Shrieve, Dennis C; Salter, Bill J

    2013-07-08

    It is the purpose of this study to evaluate how self-expanding stents (SESs) affect esophageal cancer radiation planning target volumes (PTVs) and dose delivered to surrounding organs at risk (OARs). Ten patients were evaluated, for whom a SES was placed before radiation. A computed tomography (CT) scan obtained before stent placement was fused to the post-stent CT simulation scan. Three methods were used to represent pre-stent PTVs: 1) image fusion (IF), 2) volume approximation (VA), and 3) diameter approximation (DA). PTVs and OARs were contoured per RTOG 1010 protocol using Eclipse Treatment Planning software. Post-stent dosimetry for each patient was compared to approximated pre-stent dosimetry. For each of the three pre-stent approximations (IF, VA, and DA), the mean lung and liver doses and the estimated percentages of lung volumes receiving 5 Gy, 10 Gy, 20 Gy, and 30 Gy, and heart volumes receiving 40 Gy were significantly lower (p-values < 0.02) than those estimated in the post-stent treatment plans. The lung V5, lung V10, and heart V40 constraints were achieved more often using our pre-stent approximations. Esophageal SES placement increases the dose delivered to the lungs, heart, and liver. This may have clinical importance, especially when the dose-volume constraints are near the recommended thresholds, as was the case for lung V5, lung V10, and heart V40. While stents have established benefits for treating patients with significant dysphagia, physicians considering stent placement and radiation therapy must realize the effects stents can have on the dosimetry.

  3. 5-Year Safety and Efficacy of Resolute Zotarolimus-Eluting Stent: The RESOLUTE Global Clinical Trial Program.

    PubMed

    Yeh, Robert W; Silber, Sigmund; Chen, Lianglong; Chen, Shaoliang; Hiremath, Shirish; Neumann, Franz-Josef; Qiao, Shubin; Saito, Shigeru; Xu, Bo; Yang, Yuejin; Mauri, Laura

    2017-02-13

    The authors evaluated the 5-year cumulative incidence of cardiovascular events following Resolute zotarolimus-eluting stent (R-ZES) implantation. Individual trials are often underpowered to show differences for low-frequency adverse events. The R-ZES was studied in 10 prospective clinical trials, designed with identical adverse event definitions, ascertainment, and adjudication. The RESOLUTE Global Clinical Trial Program includes 7,618 patients treated with R-ZES: RESOLUTE first-in-human study (N = 139), RESOLUTE All Comers (N = 1,140), RESOLUTE International (N = 2,349), RESOLUTE US (N = 1,402), RESOLUTE US 38 mm (N = 114), RESOLUTE Japan (N = 100), RESOLUTE Japan Small Vessel Study (N = 65), RESOLUTE Asia (N = 311), RESOLUTE China Randomized Controlled Trial (N = 198), and RESOLUTE China Registry (N = 1,800). The 5-year cumulative incidence of events was calculated. The 5-year cumulative incidence of cardiac events was 13.4% for target lesion failure and included 5.0% cardiac death, 4.4% target vessel myocardial infarction, and 6.3% clinically driven target lesion revascularization. Dual-antiplatelet therapy at 1, 3, and 5 years was 91%, 37%, and 32%, respectively. The 5-year cumulative incidence of definite or probable stent thrombosis was 1.2%, which comprised 0.7% at 1 year and an annualized rate of 0.1% thereafter. Five-year use of dual-antiplatelet therapy varied geographically from 63% in Japan to 11% in Europe. In the largest group of R-ZES patients examined to date, the majority of stent-related events, including target vessel myocardial infarction and stent thrombosis, occurred within the first year of implantation with much lower risks of these events out to 5 years. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Determination of ureter stent appearance on dual-energy computed tomography scan.

    PubMed

    Jepperson, Maria A; Thiel, David D; Cernigliaro, Joesph G; Broderick, Gregory A; Parker, Alexander S; Haley, William E

    2012-11-01

    To examine the dual-energy computed tomography (DECT) properties of 7 commonly used ureteral stents to optimize stent selection for calculi monitored using DECT. The use of DECT to evaluate renal and ureteral calculi has recently increased. Seven stents were individually placed in a fish bowl phantom and imaged using a Siemens Somatom Definition Flash CT scanner. DECT peak tube potentials of 80 and 140 kVp and 100 and 140 kVp were used, reflecting our current dual-energy protocols. These were compared to 31 in vivo stents of known composition. The data were reconstructed on a multimodality WorkPlace (Siemens) using CT syngo Post-Processing Suite software. The average patient age was 64 years (range 27-90). The average body mass index was 31.9 kg/m(2) (range 24-51.6). Of the 27 patients, 4 had uric acid stones and 22 had calcium-based stones; 1 patient had undergone renal transplantation. No difference was seen in the dual-energy characterization of stents from the same manufacturer. All imaged Cook and Bard stents had a dual-energy characterization that approached that of calcium stones (blue). All Boston Scientific and Gyrus ACMI stents had a dual-energy characterization resembling that of uric acid stones (red). The present study evaluated the stent appearance on DECT for various stent manufacturers. This information will aid in the optimal stent selection for patients undergoing treatment of renal calculi and followed up with DECT. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Biofilms and Physical Deposits on Nasolacrimal Silastic Stents Following Dacryocystorhinostomy: Is There a Difference Between Ocular and Nasal Segments?

    PubMed

    Ali, Mohammad Javed; Baig, Farhana; Lakshman, Mekala; Naik, Milind N

    2015-01-01

    The aims of this study were to examine the presence of biofilms and physical deposits on ocular and nasal segments of silastic nasolacrimal duct stents inserted after dacryocystorhinostomy and to document any differences. A prospective interventional study was performed on a series of patients undergoing dacryocystorhinostomy with Crawford stent insertion. All the patient samples were retrieved 4 weeks after an endoscopic dacryocystorhinostomy. None of the patients had any evidence of postoperative infection. The ocular and nasal segments were separated during retrieval. After removal, the stent segments were subjected to biofilm and physical deposit analysis using standard protocols of scanning electron microscopy. These stent segments were compared against sterile stents which acted as controls. A total of 11 stents were studied. Nine were consecutive patient samples and 2 were sterile stents. The ocular and nasal segments of all the stents demonstrated evidence of biofilm formation and physical deposits. However, the deposits and biofilms were thicker and extensive in the ocular segment, although more focal in nature. In contrast, the nasal segments showed thinner biofilms and sparser deposits but were more diffuse in nature. The presence of different-sized organisms within the exopolysaccharide matrix and in between the deposits suggests the existence of polymicrobial communities. This is the first study to report the differences between ocular and nasal segments of lacrimal stents. These differences could propel further studies on stent biomechanics and their interactions with ocular and nasal tissues, following a dacryocystorhinostomy.

  6. Use of ureteral stent in extracorporeal shock wave lithotripsy for upper urinary calculi: a systematic review and meta-analysis.

    PubMed

    Shen, Pengfei; Jiang, Min; Yang, Jie; Li, Xiong; Li, Yutao; Wei, Wuran; Dai, Yi; Zeng, Hao; Wang, Jia

    2011-10-01

    This systematic review was performed to assess the necessity and complications of stenting before extracorporeal shock wave lithotripsy in the management of upper urinary stones. A systematic research of PubMed®, EMBASE® and the Cochrane Library was performed to identify all randomized controlled trials. The comparisons were about the outcomes and complications of extracorporeal shock wave lithotripsy in the management of upper urinary stones with or without Double-J stenting before extracorporeal shock wave lithotripsy, including stone-free rate, Steinstrasse, lower urinary tract symptoms, hematuria, fever, urinary tract infection, pain and analgesia, auxiliary treatment, and nausea and vomiting. We used the Cochrane Collaboration's Review Manager (RevMan) 5.0.2 software for statistical analysis. Eight randomized controlled trials were included in analysis that reported 876 patients in total, divided into the stented group of 453 and the stentless group of 423. All studies recorded the stone-free rate and the results of the meta-analysis showed no difference between the groups (RR 0.97, 95% CI 0.91-1.03, p = 0.27). The total incidence of Steinstrasse in the stented group was similar to that of the stentless group with the exception of 1 study. However, the incidence of lower urinary tract symptoms was significantly higher in the stented group than in the stentless group (RR 4.10, 95% CI 2.21-7.61, p <0.00001). Significant differences could not be found in hematuria, fever, urinary tract infection, pain and analgesia, auxiliary treatment, or nausea and vomiting between the groups. The systematic review suggested significant advantages of stenting before extracorporeal shock wave lithotripsy compared to in situ extracorporeal shock wave lithotripsy in terms of Steinstrasse. However, stenting did not benefit stone-free rate and auxiliary treatment after extracorporeal shock wave lithotripsy, and it induced more lower urinary tract symptoms. More high quality, randomized controlled trials are needed to address this issue. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Less is more: as less as reasonably achievable stenting (ALARAS) strategy in the femoropopliteal area.

    PubMed

    Deloose, Koen; Callaert, Joren

    2018-05-23

    Although evidence supports that the performance of drug coated balloons seems to be lesion complexity independent, it is quite clear that in long lesions, severe calcified lesions and chronic total occlusions, the bail out stent ratio is very high and that the "leaving nothing behind" strategy remains a dream in a lot of our daily cases. On the other side of the spectrum, "full metal jackets" of nitinol stents are creating even more problems. Stent fractures, intimal hyperplasia and reintervention difficulties complicate the recurrent vascular disease treatment. The go-between with the "As Less As Reasonably Achievable Stenting"-strategy (ALARAS), earlier named with a bad name "spot" stenting, seems the most attractive one. Scaffolding where needed and allowing freedom of vessel motion will lead to reduction of TLR rates. New technologies like the Tack Endovascular System and the Vascuflex MultiLOC MSD are responding very well tot this idea. Animal tests and pivotal trials (like TOBA and LOCOMOTIVE trials) already showed with both devices good results in terms of patencies and freedom from target lesion revascularizations, and... with less metallic implants. Primary patency at 12 months was 76.4% and 85.7% in the TOBA and LOCOMOTIVE trial respectively. Target lesion revascularization at 12 months was 10.5% and 9.3% respectively. In an era of "leaving nothing behind", post-angioplasty dissections are more frequent than ever. With a direct link between lesion complexity, dissections and increase of TLR rates, scaffolding solutions remains essential. The "As Less As Reasonably Achievable Stenting" (ALARAS) strategy tries to leave as little metal behind as possible, minimizing the risk of stent fractures, allowing freedom of vessel motion and reducing TLR rates. However, the lack of clear strategies and guidelines in where to scaffold which kind of dissections is the biggest issue at the moment. More objective classifications based on newer types of imaging like intra-operative ultrasound, IVUS, OCT and/or FFR pressure wire gradient measurements will potentially offer more solutions in this interesting field.

  8. Plastic or metal stents for benign extrahepatic biliary strictures: a systematic review

    PubMed Central

    2009-01-01

    Background Benign biliary strictures may be a consequence of surgical procedures, chronic pancreatitis or iatrogenic injuries to the ampulla. Stents are increasingly being used for this indication, however it is not completely clear which stent type should be preferred. Methods A systematic review on stent placement for benign extrahepatic biliary strictures was performed after searching PubMed and EMBASE databases. Data were pooled and evaluated for technical success, clinical success and complications. Results In total, 47 studies (1116 patients) on outcome of stent placement were identified. No randomized controlled trials (RCTs), one non-randomized comparative studies and 46 case series were found. Technical success was 98,9% for uncovered self-expandable metal stents (uSEMS), 94,8% for single plastic stents and 94,0% for multiple plastic stents. Overall clinical success rate was highest for placement of multiple plastic stents (94,3%) followed by uSEMS (79,5%) and single plastic stents (59.6%). Complications occurred more frequently with uSEMS (39.5%) compared with single plastic stents (36.0%) and multiple plastic stents (20,3%). Conclusion Based on clinical success and risk of complications, placement of multiple plastic stents is currently the best choice. The evolving role of cSEMS placement as a more patient friendly and cost effective treatment for benign biliary strictures needs further elucidation. There is a need for RCTs comparing different stent types for this indication. PMID:20017920

  9. [Assessment of the course of ischemic heart disease after placement of stents with drug covering and uncovered metal stents: data of 3 years follow-up].

    PubMed

    Buza, V V; Karpov, Iu A; Samko, A N; Deev, A D; Lopukhova, V V; Levitskiĭ, I V; Sozykin, A V

    2009-01-01

    The placement of sirolimus-eluting stents decreases the frequency of repeat revascularization procedures in patients undergoing percutaneous coronary intervention (PCI) in randomized clinical trials. However, there is uncertainty about the effectiveness of sirolimus-eluting stents, and increasing concern about their safety in routine clinical practice. From the prof. Samko PCI laboratory in Moscow, Russia, we identified 426 patients, who received either bare-metal stents alone or sirolimus-eluting stents alone during an index PCI procedure between March 1, 2002, and September 31, 2004.The primary outcomes of the study were the rates of target-lesion revascularization, myocardial infarction, death, late stent thrombosis. The 3-year rate of target-lesion revascularization was significantly lower among patients who received sirolimus-eluting stents than among those who received bare-metal stents (3.1% vs. 19 %, p=0.001). The 3-year mortality rate was not different between the bare-metal stent group and the sirolimus eluting stent group (5.9% vs. 7.2%, p=0.68), the 3-year rate of all ARC late stent thrombosis was similar in the two groups (5.9% and 7.2%, respectively; p=0.95). Sirolimus-eluting stents are effective in reducing the need for target-vessel revascularization without significantly increased rates of death, late stent thrombosis, myocardial infarction.

  10. Computational Study of Axial Fatigue for Peripheral Nitinol Stents

    NASA Astrophysics Data System (ADS)

    Meoli, Alessio; Dordoni, Elena; Petrini, Lorenza; Migliavacca, Francesco; Dubini, Gabriele; Pennati, Giancarlo

    2014-07-01

    Despite their success as primary treatment for vascular diseases, Nitinol peripheral stents are still affected by complications related to fatigue failure. Hip and knee movements during daily activities produce large and cyclic deformations of the superficial femoral artery, that concomitant to the effects of pulsatile blood pressure, may cause fatigue failure in the stent. Fatigue failure typically occurs in cases of very extended lesions, which often require the use of two or more overlapping stents. In this study, finite element models were used to study the fatigue behavior of Nitinol stents when subjected to cyclic axial compression in different conditions. A specific commercial Nitinol stent was chosen for the analysis and subjected to cyclic axial compression typical of the femoral vascular region. Three different configurations were investigated: stent alone, stent deployed in a tube, and two overlapping stents deployed in a tube. Results confirm that stent oversizing has an influence in determining both the mean and amplitude strains induced in the stent and plays an important role in determining the fatigue response of Nitinol stents. In case of overlapping stents, numerical results suggest higher amplitude strains concentrate in the region close to the overlapping portion where the abrupt change in stiffness causes higher cyclic compression. These findings help to explain the high incidence of stent fractures observed in various clinical trials located close to the overlapping portion.

  11. Three-dimensional reconstruction of coronary stents in vivo based on motion compensated X-ray angiography

    NASA Astrophysics Data System (ADS)

    Schäfer, Dirk; Movassaghi, Babak; Grass, Michael; Schoonenberg, Gert; Florent, Raoul; Wink, Onno; Klein, Andrew J. P.; Chen, James Y.; Garcia, Joel; Messenger, John C.; Carroll, John D.

    2007-03-01

    The complete expansion of the stent during a percutaneous transluminal coronary angioplasty (PTCA) procedure is essential for treatment of a stenotic segment of a coronary artery. Inadequate expansion of the stent is a major predisposing factor to in-stent restenosis and acute thrombosis. Stents are positioned and deployed by fluoroscopic guidance. Although the current generation of stents are made of materials with some degree of radio-opacity to detect their location after deployment, proper stent expansion is hard to asses. In this work, we introduce a new method for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The acquisition protocol consist of a propeller rotation of the X-ray C-arm system of 180°, which ensures sufficient angular coverage for volume reconstruction. The angiographic projections were acquired at 30 frames per second resulting in 180 projections during a 7 second rotational run. The motion of the stent is estimated from the automatically tracked 2D coordinates of the markers on the balloon catheter. This information is used within a motion-compensated reconstruction algorithm. Therefore, projections from different cardiac phases and motion states can be used, resulting in improved signal-to-noise ratio of the stent. Results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current X-ray and intravascular ultrasound techniques.

  12. National trends in carotid artery revascularization surgery.

    PubMed

    Dumont, Travis M; Rughani, Anand I

    2012-06-01

    Several randomized trials have emerged with conflicting data on the overall safety of carotid artery stenting (CAS) in comparison with carotid endarterectomy (CEA). The authors hypothesize that changes in national trends correspond to publication of randomized trials, including an increase in utilization of CAS after publication of trials favorable to CAS (for example, Carotid and Vertebral Artery Transluminal Angioplasty Study [CAVATAS] and Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy [SAPPHIRE]) and decrease in utilization of CAS after publication of trials favorable to CEA (for example, Endarterectomy versus Stenting in Patients with Symptomatic Severe Carotid Stenosis [EVA3-S] and Stent-Supported Percutaneous Angioplasty of the Carotid Artery versus Endarterectomy [SPACE]). The Nationwide Inpatient Sample was obtained for the years 1998-2008. Individual cases were isolated for principal diagnosis of unilateral or bilateral carotid artery stenosis or occlusion undergoing CEA or CAS. The percentage of CAS for all carotid revascularization procedures was calculated for each year. Perioperative inpatient morbidity, including stroke or death, were calculated and compared. The percentage of patients undergoing CAS increased yearly from the start of the observed period to the end, with the exception of a decrease in 2007. The peak utilization of CAS for carotid artery revascularization procedures was 15% of all cases in 2006. The stroke or death rate was consistent at 5% among all patients undergoing CEA for all years, while the incidence of stroke or death decreased among patients undergoing CAS from 9% in 1998 to 5% in 2008. The practice of CAS in the US is expanding, from less than 3% of all carotid artery revascularization procedures to 13% in 2008. The utilization of CAS was seen to correlate with publication of randomized trials. Utilization nearly doubled in 2005 after publication of the CAS-favorable SAPPHIRE in 2004, and decreased by 22% after publication of the CEA-favorable EVA-3S and SPACE in 2007. With the publication of Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST), the authors predict a resultant increase in the rate of CAS for carotid artery disease in the upcoming years.

  13. The role of brachytherapy and Cutting Balloon angioplasty in the current treatment of stent restenosis.

    PubMed

    Bonan, Raoul

    2004-09-01

    The Gamma I, START and INHIBIT trials conclusively demonstrate the feasibility, safety and efficacy of intracoronary radiation as the treatment of choice for stent restenosis. Further reports confirm this finding and extend the indications. Vascular brachytherapy should be made available for all patients with diffuse stent restenosis. Specific devices such as cutting balloons may improve the procedure but does not seem to have an impact alone on the evolution.

  14. [Cost-effectiveness trial of self-expandable metal stents and plastic biliary stents in malignant biliary obstruction].

    PubMed

    Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán

    2016-02-14

    Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.

  15. Aggressive medical treatment with or without stenting in high-risk patients with intracranial artery stenosis (SAMMPRIS): the final results of a randomised trial.

    PubMed

    Derdeyn, Colin P; Chimowitz, Marc I; Lynn, Michael J; Fiorella, David; Turan, Tanya N; Janis, L Scott; Montgomery, Jean; Nizam, Azhar; Lane, Bethany F; Lutsep, Helmi L; Barnwell, Stanley L; Waters, Michael F; Hoh, Brian L; Hourihane, J Maurice; Levy, Elad I; Alexandrov, Andrei V; Harrigan, Mark R; Chiu, David; Klucznik, Richard P; Clark, Joni M; McDougall, Cameron G; Johnson, Mark D; Pride, G Lee; Lynch, John R; Zaidat, Osama O; Rumboldt, Zoran; Cloft, Harry J

    2014-01-25

    Early results of the Stenting and Aggressive Medical Management for Preventing Recurrent stroke in Intracranial Stenosis trial showed that, by 30 days, 33 (14·7%) of 224 patients in the stenting group and 13 (5·8%) of 227 patients in the medical group had died or had a stroke (percentages are product limit estimates), but provided insufficient data to establish whether stenting offered any longer-term benefit. Here we report the long-term outcome of patients in this trial. We randomly assigned (1:1, stratified by centre with randomly permuted block sizes) 451 patients with recent transient ischaemic attack or stroke related to 70-99% stenosis of a major intracranial artery to aggressive medical management (antiplatelet therapy, intensive management of vascular risk factors, and a lifestyle-modification programme) or aggressive medical management plus stenting with the Wingspan stent. The primary endpoint was any of the following: stroke or death within 30 days after enrolment, ischaemic stroke in the territory of the qualifying artery beyond 30 days of enrolment, or stroke or death within 30 days after a revascularisation procedure of the qualifying lesion during follow-up. Primary endpoint analysis of between-group differences with log-rank test was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT 00576693. During a median follow-up of 32·4 months, 34 (15%) of 227 patients in the medical group and 52 (23%) of 224 patients in the stenting group had a primary endpoint event. The cumulative probability of the primary endpoints was smaller in the medical group versus the percutaneous transluminal angioplasty and stenting (PTAS) group (p=0·0252). Beyond 30 days, 21 (10%) of 210 patients in the medical group and 19 (10%) of 191 patients in the stenting group had a primary endpoint. The absolute differences in the primary endpoint rates between the two groups were 7·1% at year 1 (95% CI 0·2 to 13·8%; p=0·0428), 6·5% at year 2 (-0·5 to 13·5%; p=0·07) and 9·0% at year 3 (1·5 to 16·5%; p=0·0193). The occurrence of the following adverse events was higher in the PTAS group than in the medical group: any stroke (59 [26%] of 224 patients vs 42 [19%] of 227 patients; p=0·0468) and major haemorrhage (29 [13%]of 224 patients vs 10 [4%] of 227 patients; p=0·0009). The early benefit of aggressive medical management over stenting with the Wingspan stent for high-risk patients with intracranial stenosis persists over extended follow-up. Our findings lend support to the use of aggressive medical management rather than PTAS with the Wingspan system in high-risk patients with atherosclerotic intracranial arterial stenosis. National Institute of Neurological Disorders and Stroke (NINDS) and others. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Aggressive medical treatment with or without stenting in high-risk patients with intracranial artery stenosis (SAMMPRIS): the final results of a randomised trial

    PubMed Central

    Derdeyn, Colin P; Chimowitz, Marc I; Lynn, Michael J; Fiorella, David; Turan, Tanya N; Janis, L Scott; Montgomery, Jean; Nizam, Azhar; Lane, Bethany F; Lutsep, Helmi L; Barnwell, Stanley L; Waters, Michael F; Hoh, Brian L; Hourihane, J Maurice; Levy, Elad I; Alexandrov, Andrei V; Harrigan, Mark R; Chiu, David; Klucznik, Richard P; Clark, Joni M; McDougall, Cameron G; Johnson, Mark D; Pride, G Lee; Lynch, John R; Zaidat, Osama O; Rumboldt, Zoran; Cloft, Harry J

    2014-01-01

    Summary Background Early results of the Stenting and Aggressive Medical Management for Preventing Recurrent stroke in Intracranial Stenosis trial showed that, by 30 days, 33 (14·7%) of 224 patients in the stenting group and 13 (5·8%) of 227 patients in the medical group had died or had a stroke (percentages are product limit estimates), but provided insufficient data to establish whether stenting offered any longer-term benefit. Here we report the long-term outcome of patients in this trial. Methods We randomly assigned (1:1, stratified by centre with randomly permuted block sizes) 451 patients with recent transient ischaemic attack or stroke related to 70–99% stenosis of a major intracranial artery to aggressive medical management (antiplatelet therapy, intensive management of vascular risk factors, and a lifestyle-modification programme) or aggressive medical management plus stenting with the Wingspan stent. The primary endpoint was any of the following: stroke or death within 30 days after enrolment, ischaemic stroke in the territory of the qualifying artery beyond 30 days of enrolment, or stroke or death within 30 days after a revascularisation procedure of the qualifying lesion during follow-up. Primary endpoint analysis of between-group differences with log-rank test was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT 00576693. Findings During a median follow-up of 32·4 months, 34 (15%) of 227 patients in the medical group and 52 (23%) of 224 patients in the stenting group had a primary endpoint event. The cumulative probability of the primary endpoints was smaller in the medical group versus the percutaneous transluminal angioplasty and stenting (PTAS) group (p=0·0252). Beyond 30 days, 21 (10%) of 210 patients in the medical group and 19 (10%) of 191 patients in the stenting group had a primary endpoint. The absolute differences in the primary endpoint rates between the two groups were 7·1% at year 1 (95% CI 0·2 to 13·8%; p=0·0428), 6·5% at year 2 (−0·5 to 13·5%; p=0·07) and 9·0% at year 3 (1·5 to 16·5%; p=0·0193). The occurrence of the following adverse events was higher in the PTAS group than in the medical group: any stroke (59 [26%] of 224 patients vs 42 [19%] of 227 patients; p=0·0468) and major haemorrhage (29 [13%] of 224 patients vs 10 [4%] of 227 patients; p=0·0009). Interpretation The early benefit of aggressive medical management over stenting with the Wingspan stent for high-risk patients with intracranial stenosis persists over extended follow-up. Our findings lend support to the use of aggressive medical management rather than PTAS with the Wingspan system in high-risk patients with atherosclerotic intracranial arterial stenosis. PMID:24168957

  17. Long-term efficacy and safety of carotid artery stenting versus endarterectomy: A meta-analysis of randomized controlled trials

    PubMed Central

    Xu, Biao; Wang, Lian

    2017-01-01

    Background Many recent trials have investigated the long-term efficacy and safety of endarterectomy versus stenting in treating patients with carotid artery stenosis. We aimed to determine the long-term comparative efficacy and safety of both procedures by pooling this evidence in a meta-analysis. Methods We searched PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials for studies published until May 6, 2016. Randomized controlled trials, which reported outcomes of interest with a median follow-up of at least 4-year, were included. Results Eight trials involving 7005 patients and 41824 patient-years of follow-up were included. In terms of the periprocedural outcomes, stenting was associated with a lower risk of myocardial infarction (OR: 0.51; 95% CI: 0.33 to 0.80; P = 0.003) but a higher risk of death or stroke (the composite endpoint, OR: 1.76; 95% CI: 1.38 to 2.25; P < 0.0001), a result that was primarily driven by minor stroke (OR: 2.19; 95% CI: 1.59 to 3.01; P < 0.0001), less so by periprocedural death (OR: 1.68; 95% CI: 0.82 to 3.44; P = 0.16) and major stroke (OR: 1.41; 95% CI: 0.95 to 2.09; P = 0.09). In terms of the long-term outcomes, stenting was associated with a higher risk of stroke (OR 1.45; 95% CI: 1.22 to 1.73; P < 0.0001) and the composite outcome of death or stroke (OR 1.25; 95% CI: 1.05 to 1.48; P = 0.01). No difference was found in long-term all-cause mortality between stenting and endarterectomy (OR: 1.09; 95% CI: 0.95 to 1.26; P = 0.21) and restenosis (OR: 1.48 (95% CI: 0.93 to 2.35; P = 0.10). No evidence of significant heterogeneity was found in any of the analyses. Conclusions Carotid endarterectomy was found to be superior to stenting for short- and long-term outcomes, although endarterectomy was associated with a higher risk of periprocedural myocardial infarction. Carotid endarterectomy should be offered as the first choice for carotid stenosis at present, however, more evidence is needed because rapid progress in concurrent devices and medical treatments is being made. PMID:28708869

  18. Biodegradable stent or balloon dilatation for benign oesophageal stricture: pilot randomised controlled trial.

    PubMed

    Dhar, Anjan; Close, Helen; Viswanath, Yirupaiahgari K; Rees, Colin J; Hancock, Helen C; Dwarakanath, A Deepak; Maier, Rebecca H; Wilson, Douglas; Mason, James M

    2014-12-28

    To undertake a randomised pilot study comparing biodegradable stents and endoscopic dilatation in patients with strictures. This British multi-site study recruited seventeen symptomatic adult patients with refractory strictures. Patients were randomised using a multicentre, blinded assessor design, comparing a biodegradable stent (BS) with endoscopic dilatation (ED). The primary endpoint was the average dysphagia score during the first 6 mo. Secondary endpoints included repeat endoscopic procedures, quality of life, and adverse events. Secondary analysis included follow-up to 12 mo. Sensitivity analyses explored alternative estimation methods for dysphagia and multiple imputation of missing values. Nonparametric tests were used. Although both groups improved, the average dysphagia scores for patients receiving stents were higher after 6 mo: BS-ED 1.17 (95%CI: 0.63-1.78) P = 0.029. The finding was robust under different estimation methods. Use of additional endoscopic procedures and quality of life (QALY) estimates were similar for BS and ED patients at 6 and 12 mo. Concomitant use of gastrointestinal prescribed medication was greater in the stent group (BS 5.1, ED 2.0 prescriptions; P < 0.001), as were related adverse events (BS 1.4, ED 0.0 events; P = 0.024). Groups were comparable at baseline and findings were statistically significant but numbers were small due to under-recruitment. The oesophageal tract has somatic sensitivity and the process of the stent dissolving, possibly unevenly, might promote discomfort or reflux. Stenting was associated with greater dysphagia, co-medication and adverse events. Rigorously conducted and adequately powered trials are needed before widespread adoption of this technology.

  19. Biodegradable stent or balloon dilatation for benign oesophageal stricture: Pilot randomised controlled trial

    PubMed Central

    Dhar, Anjan; Close, Helen; Viswanath, Yirupaiahgari K; Rees, Colin J; Hancock, Helen C; Dwarakanath, A Deepak; Maier, Rebecca H; Wilson, Douglas; Mason, James M

    2014-01-01

    AIM: To undertake a randomised pilot study comparing biodegradable stents and endoscopic dilatation in patients with strictures. METHODS: This British multi-site study recruited seventeen symptomatic adult patients with refractory strictures. Patients were randomised using a multicentre, blinded assessor design, comparing a biodegradable stent (BS) with endoscopic dilatation (ED). The primary endpoint was the average dysphagia score during the first 6 mo. Secondary endpoints included repeat endoscopic procedures, quality of life, and adverse events. Secondary analysis included follow-up to 12 mo. Sensitivity analyses explored alternative estimation methods for dysphagia and multiple imputation of missing values. Nonparametric tests were used. RESULTS: Although both groups improved, the average dysphagia scores for patients receiving stents were higher after 6 mo: BS-ED 1.17 (95%CI: 0.63-1.78) P = 0.029. The finding was robust under different estimation methods. Use of additional endoscopic procedures and quality of life (QALY) estimates were similar for BS and ED patients at 6 and 12 mo. Concomitant use of gastrointestinal prescribed medication was greater in the stent group (BS 5.1, ED 2.0 prescriptions; P < 0.001), as were related adverse events (BS 1.4, ED 0.0 events; P = 0.024). Groups were comparable at baseline and findings were statistically significant but numbers were small due to under-recruitment. The oesophageal tract has somatic sensitivity and the process of the stent dissolving, possibly unevenly, might promote discomfort or reflux. CONCLUSION: Stenting was associated with greater dysphagia, co-medication and adverse events. Rigorously conducted and adequately powered trials are needed before widespread adoption of this technology. PMID:25561787

  20. Carotid Artery Stenting: Review of Technique and Update of Recent Literature

    PubMed Central

    Ahn, Sun Ho; Prince, Ethan A.; Dubel, Gregory J.

    2013-01-01

    Stroke is the fourth leading cause of death and the number one cause of long-term disability in the United States. Carotid stenosis is an important cause of ischemic strokes, accounting for 20 to 25%. Previous studies have established carotid endarterectomy as standard of care of symptomatic patients with > 50% stenosis and asymptomatic patients with > 60% stenosis; recently, carotid artery stenting has emerged as an alternative treatment for carotid stenosis. Several studies have been published comparing carotid artery stenting with endarterectomy with mixed results. In this article, the authors discuss carotid artery stenting technique, the results from the most recent trials, and future directions. PMID:24436551

  1. New dedicated bifurcated silicone stent placement for stenosis around the primary right carina.

    PubMed

    Oki, Masahide; Saka, Hideo

    2013-08-01

    Silicone stenting has been widely used to palliate respiratory symptoms in patients suffering from airway stenosis. Although many types and shapes of stents have been developed, there is no ideal stent for stenosis around the carina between the bronchus to the right upper lobe and the bronchus intermedius (primary right carina). The purpose of this study was to evaluate the feasibility, efficacy, and safety of a new silicone stent designed for treating airway stenosis around the primary right carina. We recruited 16 patients with suspected stenosis around the primary right carina. Ten of the patients met the inclusion criteria for inserting the study stent. All stenting procedures were performed with a rigid and flexible bronchoscope under general anesthesia. The study stent could be mounted successfully on the primary right carina in all 10 patients. Five patients underwent stenting using only the new stent, and the other five underwent stenting with it on the primary right carina and a silicone Y stent on the main carina. The dyspnea index improved in eight of the 10 patients, including one who was mechanically ventilated. Early complications developed in three patients (temporary pneumonia in two and retention of secretions in one), and late complications occurred in two patients (granuloma formation in one and hemoptysis in one). Stent placement with the new silicone stent designed to fit on the primary right carina is feasible, effective, and acceptably safe. UMIN-Clinical Trials Registry; No.: UMIN000001776; URL: www.umin.ac.jp/ctr.

  2. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    PubMed

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (<30%) stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  3. A review of the iStent® trabecular micro-bypass stent: safety and efficacy

    PubMed Central

    Wellik, Sarah R; Dale, Elizabeth A

    2015-01-01

    There is a significant demand for procedures that can effectively treat glaucoma with low risk and good visual outcomes. To fill this void, procedures termed “minimally invasive glaucoma surgery”, are gaining in popularity. This review will focus on the safety and efficacy of one such minimally invasive glaucoma surgery procedure, the trabecular micro-bypass stent. This stent is intended to lower intraocular pressure by directly cannulating Schlemm’s canal and thereby enhancing aqueous outflow. Recent randomized controlled trials and case series have demonstrated the micro-bypass stent to be a relatively safe procedure, with limited complications and no serious adverse sequelae. The most common complication across all studies was stent obstruction or malposition, which generally did not result in any adverse outcome in vision or pressure control. In addition, increased rates of hypotony, choroidal hemorrhage, or infection were not seen with the micro-bypass stent in comparison to cataract surgery alone. PMID:25931808

  4. Angiographic outcomes following stenting or coronary artery bypass surgery of the left main coronary artery: fifteen-month outcomes from the synergy between PCI with TAXUS express and cardiac surgery left main angiographic substudy (SYNTAX-LE MANS).

    PubMed

    Morice, Marie-Claude; Feldman, Ted E E; Mack, Michael J; Ståhle, Elisabeth; Holmes, David R; Colombo, Antonio; Morel, Marie-Angèle; van den Brand, Marcel; Serruys, Patrick W; Mohr, Friedrich; Carrié, Didier; Fournial, Gérard; James, Stefan; Leadley, Katrin; Dawkins, Keith D; Kappetein, A Pieter

    2011-10-30

    The SYNTAX-LE MANS substudy prospectively evaluated 15-month angiographic and clinical outcomes in patients with treated left main (LM) disease. In the SYNTAX trial, 1,800 patients with three-vessel and/or LM disease were randomised to either CABG or PCI; of these, 271 LM patients were prospectively assigned to receive a 15-month angiogram. The primary endpoint for the CABG arm was the ratio of ≥50% to <100% obstructed/occluded grafts bypassing LM lesions to the number placed. The primary endpoint for the PCI arm was the proportion of patients with ≤50% diameter stenosis ('patent' stents) of treated LM lesions. Per protocol, no formal comparison between CABG and PCI arms was intended based on the differing primary endpoints. Available 15-month angiograms were analysed for 114 CABG and 149 PCI patients. At 15 months, 9.9% (26/263) of CABG grafts were 100% occluded and an additional 5.7% (15/263) were ≥50% to <100% occluded. Overall, 27.2% (31/114) of patients had ≥1 obstructed/occluded graft. The 15-month CABG MACCE rate was 8.8% (10/114) and MACCE at 15 months was not significantly associated with graft obstruction/occlusion (p=0.85). In the PCI arm, 92.4% (134/145) of patients had ≤50% diameter LM stenosis at 15 months (89.7% [87/97] distal LM lesions and 97.9% [47/48] non-distal LM lesions). The 15-month PCI MACCE rate was 12.8% (20/156) and this was significantly associated with lack of stent patency at 15 months (p<0.001), mainly due to repeat revascularisation. At 15 months, 15.6% (41/263) of grafts were at least 50% obstructed but this was not significantly associated with MACCE; 92.4% (134/145) of patients had stents that remained patent at 15 months, and stent restenosis was significantly associated with MACCE, predominantly due to revascularisation.

  5. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design.

    PubMed

    Diletti, Roberto; Serruys, Patrick W; Farooq, Vasim; Sudhir, Krishnankutty; Dorange, Cecile; Miquel-Hebert, Karine; Veldhof, Susan; Rapoza, Richard; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Chevalier, Bernard

    2012-11-01

    Currently, no data are available on the direct comparison between the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) and conventional metallic drug-eluting stents. The ABSORB II study is a randomized, active-controlled, single-blinded, multicenter clinical trial aiming to compare the second-generation Absorb BVS with the XIENCE everolimus-eluting metallic stent. Approximately 501 subjects will be enrolled on a 2:1 randomization basis (Absorb BVS/XIENCE stent) in approximately 40 investigational sites across Europe and New Zealand. Treated lesions will be up to 2 de novo native coronary artery lesions, each located in different major epicardial vessels, all with an angiographic maximal luminal diameter between 2.25 and 3.8 mm as estimated by online quantitative coronary angiography (QCA) and a lesion length of ≤48 mm. Clinical follow-up is planned at 30 and 180 days and at 1, 2, and 3 years. All subjects will undergo coronary angiography, intravascular ultrasound (IVUS) and IVUS-virtual histology at baseline (pre-device and post-device implantation) and at 2-year angiographic follow-up. The primary end point is superiority of the Absorb BVS vs XIENCE stent in terms of vasomotor reactivity of the treated segment at 2 years, defined as the QCA quantified change in the mean lumen diameter prenitrate and postnitrate administration. The coprimary end point is the noninferiority (reflex to superiority) of the QCA-derived minimum lumen diameter at 2 years postnitrate minus minimum lumen diameter postprocedure postnitrate by QCA. In addition, all subjects allocated to the Absorb BVS group will undergo multislice computed tomography imaging at 3 years. The ABSORB II randomized controlled trial (ClinicalTrials.gov NCT01425281) is designed to compare the safety, efficacy, and performance of Absorb BVS against the XIENCE everolimus-eluting stent in the treatment of de novo native coronary artery lesions. Copyright © 2012 Mosby, Inc. All rights reserved.

  6. Ezetimibe in Combination With Statins Ameliorates Endothelial Dysfunction in Coronary Arteries After Stenting: The CuVIC Trial (Effect of Cholesterol Absorption Inhibitor Usage on Target Vessel Dysfunction After Coronary Stenting), a Multicenter Randomized Controlled Trial.

    PubMed

    Takase, Susumu; Matoba, Tetsuya; Nakashiro, Soichi; Mukai, Yasushi; Inoue, Shujiro; Oi, Keiji; Higo, Taiki; Katsuki, Shunsuke; Takemoto, Masao; Suematsu, Nobuhiro; Eshima, Kenichi; Miyata, Kenji; Yamamoto, Mitsutaka; Usui, Makoto; Sadamatsu, Kenji; Satoh, Shinji; Kadokami, Toshiaki; Hironaga, Kiyoshi; Ichi, Ikuyo; Todaka, Koji; Kishimoto, Junji; Egashira, Kensuke; Sunagawa, Kenji

    2017-02-01

    We sought to investigate whether treatment with ezetimibe in combination with statins improves coronary endothelial function in target vessels in coronary artery disease patients after coronary stenting. We conducted a multicenter, prospective, randomized, open-label, blinded-end point trial among 11 cardiovascular treatment centers. From 2011 to 2013, 260 coronary artery disease patients who underwent coronary stenting were randomly allocated to 2 arms (statin monotherapy, S versus ezetimibe [10 mg/d]+statin combinational therapy, E+S). We defined target vessel dysfunction as the primary composite outcome, which comprised target vessel failure during treatment and at the 6- to 8-month follow-up coronary angiography and coronary endothelial dysfunction determined via intracoronary acetylcholine testing performed in cases without target vessel failure at the follow-up coronary angiography. Coadministration of ezetimibe with statins further lowered low-density lipoprotein cholesterol levels (83±23 mg/dL in S versus 67±23 mg/dL in E+S; P<0.0001), with significant decreases in oxidized low-density lipoprotein and oxysterol levels. Among patients without target vessel failure, 46 out of 89 patients (52%) in the S arm and 34 out of 96 patients (35%) in the E+S arm were found to have coronary endothelial dysfunction (P=0.0256), and the incidence of target vessel dysfunction at follow-up was significantly decreased in the E+S arm (69/112 (62%) in S versus 47/109 (43%) in E+S; P=0.0059). A post hoc analysis of post-treatment low-density lipoprotein cholesterol-matched subgroups revealed that the incidence of both target vessel dysfunction and coronary endothelial dysfunction significantly decreased in the E+S arm, with significant reductions in oxysterol levels. The CuVIC trial (Effect of Cholesterol Absorption Inhibitor Usage on Target Vessel Dysfunction after Coronary Stenting) has shown that ezetimibe with statins, compared with statin monotherapy, improves functional prognoses, ameliorating endothelial dysfunction in stented coronary arteries, and was associated with larger decreases in oxysterol levels. © 2016 American Heart Association, Inc.

  7. Intraductal Transanastomotic Stenting in Duct-to-Duct Biliary Reconstruction after Living-Donor Liver Transplantation: A Randomized Trial.

    PubMed

    Santosh Kumar, K Y; Mathew, Johns Shaji; Balakrishnan, Dinesh; Bharathan, Viju Kumar; Thankamony Amma, Binoj Sivasankara Pillai; Gopalakrishnan, Unnikrishnan; Narayana Menon, Ramachandran; Dhar, Puneet; Vayoth, Sudheer Othiyil; Sudhindran, Surendran

    2017-12-01

    Biliary complications continue to be the "Achilles heel" of living-donor liver transplantation (LDLT). The use of biliary stents in LDLT to reduce biliary complications is a controversial issue. We performed a randomized trial to study the impact of intraductal biliary stents on postoperative biliary complications after LDLT. Of the 94 LDLTs that were performed during a period of 16 months, ABO-incompatible transplants, left lobe grafts, 3 or more bile ducts on the graft, and those requiring bilioenteric drainage were excluded. Eligible patients were randomized to either a study arm (intraductal stent, n = 31) or a control arm (no stent, n = 33) by block randomization. Stratification was done, based on the number of ducts on the graft requiring anastomosis, into single (n = 20) or 2 ducts (n = 44). Ureteric stents of 3F to 5F placed across the biliary anastomosis and exiting into the duodenum for later endoscopic removal at 3 months were used. The primary end point was postoperative bile leak. Bile leak occurred in 15 of 64 (23.4%), the incidence was higher in the stented group compared with the control group (35.5% vs 12.1%; p = 0.03). Multiplicity of bile ducts and stenting were identified as risk factors for bile leak on multivariate analysis (p = 0.031 and p = 0.032). During a median follow-up of 2 years, biliary stricture developed in 9 patients (14.1%). Postoperative bile leak is a significant risk factor for the development of biliary stricture (p = 0.003). Intraductal transanastomotic biliary stenting and multiplicity of graft ducts were identified as independent risk factors for the development of postoperative biliary complications. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  8. [Clinical Evaluation of Diagnostic and Treatment Protocol of Idiopathic Retroperitoneal Fibrosis Incorporating Consideration of Possible IgG4-Related Disease].

    PubMed

    Iyoki, Takaya; Maehana, Takeshi; Tanaka, Toshiaki; Yamamoto, Motohisa; Takahashi, Hiroki; Masumori, Naoya

    2017-11-01

    About half of idiopathic retroperitoneal fibrosis might be classified as a IgG4-related disease, a newly characterized disease that is especially known to be sensitive to steroid therapy. We developed a new protocol for diagnosis and treatment of retroperitoneal fibrosis, which included aggressive diagnosis of IgG4- related disease. We retrospectively reviewed 22 cases with idiopathic retroperitoneal fibrosis that were diagnosed and treated according to our protocol. Of them, 10 patients (45.5%) had no evidence of IgG4- related disease (non-IgG4RD group), whereas 12 patients (54.5%) were diagnosed with IgG4-related disease (IgG4RD group). All patients received steroid therapy, and 13 patients (59.1%) underwent ureteral stenting or received prednisolone (PNS). There was no severe adverse event and planned steroid therapy was completed in all patients. In principle, maintenance steroid therapy was continued after induction therapy in the IgG4RD group, whereas steroid therapy was discontinued in the non-IgG4RD group. Regression of retroperitoneal plaque was achieved in all 22 patients. Four (57.1%) out of 7 patients and 3 (50.0%) out of 6 patients achieved freedom from ureteral stent or PNS in the non-IgG4RD group and IgG4RD group, respectively. All 3 patients with PNS became catheter-free after treatment, whereas only 4 (40.0%) of the 10 patients withureteral stent could become stent-free. Steroid therapy could be discontinued in 7 patients (70.0%) in the non-IgG4RD group. The results of this study suggest that similar efficacy of steroid therapy can be expected in the non-IgG4RD group and IgG4RD group.

  9. Stent thrombosis: insights on outcomes, predictors and impact of dual antiplatelet therapy interruption from the SPIRIT II, SPIRIT III, SPIRIT IV and COMPARE trials.

    PubMed

    Kedhi, Elvin; Stone, Gregg W; Kereiakes, Dean J; Serruys, Patrick W; Parise, Helen; Fahy, Martin; Simonton, Charles A; Sudhir, Krishnankutty; Sood, Poornima; Smits, Pieter C

    2012-09-01

    Recent studies have suggested that EES may reduce ST compared to PES, but no individual trial has been adequately powered for this endpoint. The incidence of stent thrombosis, as well as the impact of dual antiplatelet therapy (DAPT) discontinuation during the first two years following everolimus-eluting stent (EES) and paclitaxel-eluting stent (PES) deployment were therefore analysed from a pooled, patient-level database derived from four randomised clinical trials. Data from the SPIRIT II, SPIRIT III, SPIRIT IV and COMPARE trials (n=6,789 patients) were analysed. Two-year ST rates were determined using time-to-event methods and compared with the log-rank test. ST rates were also determined after DAPT discontinuation. EES compared to PES significantly reduced the two-year rates of ST (0.7% versus 2.3%, p=0.0001), including the interval rates of ST up to 30 days (0.2% versus 1.0%, p<0.0001), between 31 days and one year (0.2% versus 0.6%, p=0.02), and after one year (0.3% versus 0.8%, p=0.001). EES also reduced the two-year composite rate of cardiac death or MI (4.0% versus 6.6%, p=0.0001). Increased rates of ST after DAPT discontinuation beyond six months were observed in the PES cohort, but not in the EES cohort. In this large pooled analysis from four randomised trials, treatment with EES compared to PES significantly reduced the rates of ST through two years of follow-up, with a concomitant reduction in cardiac death or MI. DAPT discontinuation beyond six months may be safe with EES.

  10. Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.

    PubMed

    Win, Htut K; Caldera, Angel E; Maresh, Kelly; Lopez, John; Rihal, Charanjit S; Parikh, Manish A; Granada, Juan F; Marulkar, Sachin; Nassif, Deborah; Cohen, David J; Kleiman, Neal S

    2007-05-09

    Clinical trials that have excluded patients at high risk for cardiac events have led to commercial labeling approval of drug-eluting stents; nevertheless, such high-risk patients commonly undergo stent placement in clinical practice. The degree to which they experience cardiac events at a higher rate than non-high-risk patients is unclear. To assess the rates of major adverse cardiac events during the index admission and 1 year after the implantation of drug-eluting stents in patients with high-risk angiographic and clinical features. From July 2004 to September 2005, consecutive patients who underwent attempted stent placement at 42 different hospitals throughout the United States were enrolled in a prospective multicenter registry. We analyzed outcomes of 3323 patients who received at least 1 drug-eluting stent for a reason other than acute ST-segment elevation myocardial infarction. The study population was divided into 2 groups based on presence of at least 1 of 9 off-label characteristics based on the current US Food and Drug Administration-approved indications for sirolimus- and paclitaxel-eluting stents. The composite clinical outcomes of death, myocardial infarction, or target vessel revascularization during the index admission and death, myocardial infarction, or target lesion revascularization at 1 year were evaluated. Of the 3323 patients, 1817 (54.7%) had at least 1 off-label characteristic. During the index hospitalization, the composite clinical outcome occurred in 198 (10.9%) of patients in the off-label group and 76 (5.0%) of patients in the on-label group (adjusted odds ratio, 2.32; 95% confidence interval [CI], 1.75-3.07; P<.001). At 1 year, the composite clinical outcome occurred more often in the off-label group compared with the on-label group; 309 (17.5%) vs 131 (8.9%) (adjusted hazard ratio [HR], 2.16; 95% CI, 1.74-2.67; P<.001). Stent thrombosis also occurred more frequently among patients in the off-label group during the initial hospitalization (8 [0.4%] vs 0) and at 1 year: 29 (1.6%) vs 13 (0.9%), adjusted HR, 2.29 (95% CI, 1.02-5.16; P = .05). Compared with on-label use, off-label use of drug-eluting stents is associated with a higher rate of adverse outcomes during the index admission and at 1 year. Stent thrombosis occurred predominantly in patients who underwent off-label drug-eluting stent implantation. Clinicians should be cautious about extrapolating the benefits of drug-eluting stents over bare-metal stents observed in randomized clinical trials to higher-risk clinical settings that have not been assessed.

  11. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial.

    PubMed

    Coté, Gregory A; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K; Elmunzer, B Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of -15%. There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, -3.0% to ∞; P < .001). Given the prespecified noninferiority margin of -15%, the null hypothesis that cSEMS is less effective than plastic stents was rejected. The mean number of ERCPs to achieve resolution was lower for cSEMS (2.14) vs plastic (3.24; mean difference, 1.10; 95% CI, 0.74 to 1.46; P < .001). Among patients with benign biliary strictures and a bile duct diameter 6 mm or more in whom the covered metallic stent would not overlap the cystic duct, cSEMS were not inferior to multiple plastic stents after 12 months in achieving stricture resolution. Metallic stents should be considered an appropriate option in patients such as these. clinicaltrials.gov Identifier: NCT01221311.

  12. Surgical and anesthetic considerations for the endovascular treatment of ruptured descending thoracic aortic aneurysms.

    PubMed

    Hogendoorn, Wouter; Schlösser, Felix J V; Muhs, Bart E; Popescu, Wanda M

    2014-02-01

    Ruptured descending thoracic aortic aneurysm (rDTAA) is a life-threatening disease. In the last decade, thoracic endovascular aortic repair (TEVAR) has evolved as a viable option and is now considered the preferred treatment for rDTAAs. New opportunities as well as new challenges are faced by both the surgeon and the anesthesiologist. This review describes the impact of current developments and new modalities for the surgical and anesthetic management of rDTAAs. A collaborative approach between the anesthesiologist and surgeon during critical moments such as induction, moment of aortic occlusion and placement of the aortic stent-graft is mandatory. Important issues to consider on preoperative imaging evaluation are correct sizing of the aortic stent-graft and localization of the artery of Adamkiewicz. Emergency TEVAR should preferentially be started under local anesthesia and could be switched to general anesthesia after stent placement. Patients should be kept in permissive hypotension preoperatively and during the intervention before stent-graft deployment and relative hypertension after deployment. The use of a proactive spinal cord protection protocol could decrease the risk of spinal cord ischemia and/or paraplegia and consists of permissive hypertension after stent deployment, cerebrospinal fluid drainage to maintain adequate spinal cord perfusion, relative hypothermia and possibly use of mannitol. In order to improve outcomes of TEVAR for rDTAA, a close communication between the anesthesiologist and the surgeon and a thorough understanding of the events during the procedure is mandatory. The use of a proactive spinal cord protection protocol may decrease the rates of devastating spinal cord ischemia.

  13. Stent longitudinal integrity bench insights into a clinical problem.

    PubMed

    Ormiston, John A; Webber, Bruce; Webster, Mark W I

    2011-12-01

    Standardized bench-top compression and elongation testing was undertaken to assess the longitudinal strength of contemporary stents. Insights gained may improve clinical stent choice and deployment techniques, and facilitate future stent design improvements. The hoops of coronary stents provide radial support, and connectors hold hoops together. Strut material, shape, and thickness, along with connector number and configuration, provide the balance between stent flexibility and longitudinal integrity. Longitudinal distortion manifests as length change, strut overlap, strut separation, malapposition, and luminal obstruction. These may predispose to restenosis and stent thrombosis, obstruct passage of devices, be misinterpreted as strut fracture, and require additional stenting. The force required to compress and to elongate 7 contemporary stents was measured with an Instron universal testing machine (Norwood, Massachusetts). Stents deployed in a silicone phantom damaged by a balloon or guide catheter were imaged by microcomputed tomography to understand better the appearances and effects of longitudinal distortion. Stents with 2 connectors (Boston Scientific [Natick, Massachusetts] Omega and Medtronic [Santa Rosa, California] Driver) required significantly less force to be compressed up to 5 mm and elongated by 1 mm than designs with more connectors. The 6-connector Cypher Select required significantly more force to be elongated 5 mm than other designs. Stents with 2 connectors between hoops have less longitudinal strength when exposed to compressing or elongating forces than those with more connectors. This independent, standardized study may assist stent selection in clinical situations where longitudinal integrity is important, and may aid future design improvements. Stent longitudinal strength, the resistance to shortening or elongation, appears related to the number of connectors between hoops. Using a standardized testing protocol, designs with 2 connectors were more likely to shorten or elongate than those with more connectors. Distortion may be recognized clinically as bunching or separation of struts, and may be confused with strut fracture. Without post-dilation or further stent deployment, the patient may be at increased risk for adverse clinical events. A stent design change ensuring 3 connectors, especially at the proximal end of a stent, should increase longitudinal integrity, but perhaps at the expense of stent flexibility. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Paclitaxel Drug-Eluting Stents in Peripheral Arterial Disease: A Health Technology Assessment

    PubMed Central

    2015-01-01

    Background Peripheral arterial disease is a condition in which atherosclerotic plaques partially or completely block blood flow to the legs. Although percutaneous transluminal angioplasty and metallic stenting have high immediate success rates in treating peripheral arterial disease, long-term patency and restenosis rates in long and complex lesions remain unsatisfactory. Objective The objective of this analysis was to evaluate the clinical effectiveness, safety, cost-effectiveness and budget impact of Zilver paclitaxel self-expanding drug-eluting stents for the treatment of de novo or restenotic lesions in above-the-knee peripheral arterial disease. Data Sources Literature searches were performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews. For the economic review, a search filter was applied to limit search results to economics-related literature. Data sources for the budget impact analysis included expert opinion, published literature, and Ontario administrative data. Review Methods Systematic reviews, meta-analyses, randomized controlled trials, and observational studies were included in the clinical effectiveness review, and full economic evaluations were included in the economic literature review. Studies were included if they examined the effect of Zilver paclitaxel drug-eluting stents in de novo or restenotic lesions in above-the-knee arteries. For the budget impact analysis, 3 scenarios were constructed based on different assumptions. Results One randomized controlled trial reported a significantly higher patency rate with Zilver paclitaxel drug-eluting stents for lesions ≤ 14 cm than with angioplasty or bare metal stents. One observational study showed no difference in patency rates between Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. Zilver paclitaxel drug-eluting stents were associated with a significantly higher event-free survival rate than angioplasty, but the event-free survival rate was similar for Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. No economic evaluations compared Zilver paclitaxel drug-eluting stents with bare metal stents or angioplasty for peripheral arterial disease. A budget impact analysis showed that the cost savings associated with funding of Zilver paclitaxel drug-eluting stents would be $470,000 to $640,000 per year, assuming that the use of the Zilver paclitaxel drug-eluting stent was associated with a lower risk of subsequent revascularization. Conclusions Based on evidence of low to moderate quality, Zilver paclitaxel drug-eluting stents were associated with a higher patency rate than angioplasty or bare metal stents, and with fewer adverse events than angioplasty. The effectiveness and safety of Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons were similar. PMID:26719778

  15. Multidisciplinary approach to carotid stenting.

    PubMed

    Mak, C S; Chambers, B R; Clark, D J; Molan, M; Brooks, M; Roberts, N; Fell, G; Roberts, A K; New, G; Donnan, G A

    2011-11-01

    Stroke neurologists, vascular surgeons, interventional neuroradiologists and interventional cardiologists have embraced carotid angioplasty and stenting (CAS) because of potential advantages over carotid endarterectomy (CEA). At Austin Health, a multidisciplinary neuro-interventional group was formed to standardise indications and facilitate training. The aims of this study were to describe our organisational model and to determine whether 30-day complications and early outcomes were similar to those of major trials. A clinical protocol was developed to ensure optimal management. CAS was performed on patients with high medical risk for CEA, with technically difficult anatomy for CEA, or who were randomised to CAS in a trial. From October 2003 to May 2008, 47 patients (34 male, mean age 71.5) underwent CAS of 50 carotid arteries. Forty-three cases had ipsilateral carotid territory symptoms within the previous 12 months. The main indications for CAS were high risk for CEA (n= 17) and randomised to CAS (n= 21). Interventionists were proctored in 27 cases. The procedural success rate was 94% with two cases abandoned because of anatomical problems and one because of on-table angina. Hypotension requiring vasopressor therapy occurred in 12 cases (24%). The duration of follow up was one to 44 months (mean 6.8 months). The 30-day rate of peri-procedural stroke or death was 6% and the one-year rate of peri-procedural stroke or death or subsequent ipsilateral stroke was 10.6%. Restenosis occurred in 13% (all asymptomatic). A multidisciplinary approach is a useful strategy for initiating and sustaining a CAS programme. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  16. Surgical Success in Chronic Pancreatitis: Sequential Endoscopic Retrograde Cholangiopancreatography and Surgical Longitudinal Pancreatojejunostomy (Puestow Procedure).

    PubMed

    Ford, Kathryn; Paul, Anu; Harrison, Phillip; Davenport, Mark

    2016-06-01

    Introduction Chronic pancreatitis (CP) can be a cause of recurrent, severe, disabling abdominal pain in children. Surgery has been suggested as a useful therapy, although experience is limited and the results unpredictable. We reviewed our experience of a two-stage protocol-preliminary endoscopic retrograde cholangiopancreatography (ERCP) and duct stenting, and if symptoms resolved, definitive surgical decompression by longitudinal pancreatojejunostomy (LPJ) (Puestow operation). Patients and Methods This is a single-center, retrospective review of children with established CP who underwent an LPJ between February 2002 and September 2012. A questionnaire was completed (incorporating visual analog scale pain and lifestyle scores) to assess functional outcome. Data are expressed as median (range). Results In this study, eight (M:F ratio of 4:4) children underwent an LPJ and one female child had a more limited pancreatojejunostomy anastomosis following preliminary ERCP and stent placement where possible. Diagnoses included hereditary pancreatitis (n = 3), idiopathic or structural pancreatitis (n = 5), and duct stricture following radiotherapy (n = 1). Median duct diameter presurgery was 5 (4-11) mm. Endoscopic placement of a Zimmon pancreatic stent was possible in six with relief of symptoms in all. Median age at definitive surgery was 11 (range, 7-17) years with a median postoperative stay of 9 (range, 7-12) days and a follow-up of 6 (range, 0.5-12) years. All children reported markedly reduced episodes of pain postprocedure. One developed diabetes mellitus, while three had exocrine deficiency (fecal elastase < 200 µg/g) requiring enzyme supplementation. The child with limited LPJ had symptomatic recurrence and required restenting and further surgery to widen the anastomosis to become pain free. Conclusion ERCP and stenting provide a therapeutic trial to assess possible benefit of a definitive duct drainage procedure. LPJ-the modified Puestow operation was safe and complication-free with good medium-term relief of symptoms. We were not able to identify a consistent etiology-associated outcome. Georg Thieme Verlag KG Stuttgart · New York.

  17. Percuflex Helical Ureteral Stents Significantly Reduce Patient Analgesic Requirements Compared to Control Stents.

    PubMed

    Chew, Ben H; Rebullar, Karla A; Harriman, David; McDougall, Elspeth; Paterson, Ryan F; Lange, Dirk

    2017-12-01

    Ureteral stent symptoms are experienced by the majority of patients with ureteral stents. No one stent or technology has shown a clear advantage. The Helical™ stent, a spirally cut stent made of proprietary Percuflex™ material, was designed to conform to the shape of the ureter and better accommodate patient movement. We prospectively sought to compare unscheduled visits, analgesic use, and pain scores in patients who received a Percuflex Helical ureteral stent following ureteroscopy compared to a historical control group. Fifteen (n = 15) patients undergoing ureteroscopy for the treatment of kidney stones were consented for study. A Percuflex Helical ureteral stent was inserted after treating the urinary stone. The historical control group consisted of 30 patients, from a previous (ketorolac eluting) ureteral stent study utilizing the same protocol and clinical monitoring forms, who received a regular Percuflex ureteral stent. The control patients were matched by age and sex. The primary study outcome was to compare unscheduled visits. Secondary outcomes included comparison of Visual Pain Analog Scale (VPAS) scores and analgesic use between the two groups. There were no differences in the gender, age, BMI, or stone characteristics between groups. Both groups underwent retrograde ureteroscopy using holmium:YAG laser lithotripsy and stone fragmentation. There was a significant reduction in the amount of analgesics required in the Helical stent group (4.4 ± 7.99 mg morphine equivalents) compared to controls (16.75 ± 18.31 mg, p = 0.0035) to achieve similar VPAS scores. There was no difference in unscheduled visits (20%) or VPAS scores (13.84 ± 13.68 helical vs 14.29 ± 11.58 control, p = 0.7910) between groups. Patients who received a Percuflex Helical ureteral stent required significantly fewer analgesics than those who received a Percuflex stent and both had equivalent pain scores.

  18. A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus: The RESERVOIR Clinical Trial.

    PubMed

    Romaguera, Rafael; Gómez-Hospital, Joan A; Gomez-Lara, Josep; Brugaletta, Salvatore; Pinar, Eduardo; Jiménez-Quevedo, Pilar; Gracida, Montserrat; Roura, Gerard; Ferreiro, Jose L; Teruel, Luis; Montanya, Eduard; Fernandez-Ortiz, Antonio; Alfonso, Fernando; Valgimigli, Marco; Sabate, Manel; Cequier, Angel

    2016-01-11

    The aim of this study was to compare the efficacy of amphilimus-eluting stents (AES) with that of everolimus-eluting stents (EES) in patients with diabetes mellitus (DM). The AES is a polymer-free drug-eluting stent that elutes sirolimus formulated with an amphiphilic carrier from laser-dug wells. This technology could be associated with a high efficacy in patients with DM. This was a multicenter, randomized, noninferiority trial. Patients with DM medically treated with oral glucose-lowering agents or insulin and de novo coronary lesions were randomized in a 1:1 fashion to AES or EES. The primary endpoint was the neointimal (NI) volume obstruction assessed by optical coherence tomography at 9-month follow-up. A total of 116 lesions in 112 patients were randomized. Overall, 40% were insulin-treated patients, with a median HbA1c of 7.3% (interquartile range: 6.7% to 8.0%). The primary endpoint, NI volume obstruction, was 11.97 ± 5.94% for AES versus 16.11 ± 18.18% for EES, meeting the noninferiority criteria (p = 0.0003). Pre-specified subgroup analyses showed a significant interaction between stent type and glycemic control (p = 0.02), with a significant reduction in NI hyperplasia in the AES group in patients with the higher HbA1c (p = 0.03). By quantitative coronary angiography, in-stent late loss was 0.14 ± 0.24 for AES versus 0.24 ± 0.57 mm for EES (p = 0.27), with a larger minimal lumen diameter at follow-up for AES (p = 0.02), mainly driven by 2 cases of occlusive restenosis in the EES group. AES are noninferior to EES for the coronary revascularization of patients with DM. These results suggest a high efficacy of the AES and may support the potential benefit of this stent in patients with DM. (A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus [RESERVOIR]; NCT01710748). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    PubMed

    Lu, Huangling; Kalkman, Deborah N; Grundeken, Maik J; Tijssen, Jan G P; Wykrzykowska, Joanna J; de Winter, Robbert J; Koch, Karel T

    2018-02-01

    With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections using the novel Xposition delivery device as compared with the conventional delivery device. A total of 38 patients who were treated with the self-apposing STENTYS stent and with OCT assessment at our center were retrospectively analysed. Twenty patients were treated using the Xposition- and 18 using the conventional delivery device. OCT was performed according to study protocol. Frames with poor quality were excluded. A total of 12(18%) dissections were detected, 7(20%) in the Xposition delivery device group, and 5(15%) in the conventional group (p = 1). Using the Xposition delivery device 4(33%) dissections were found proximally, using the conventional delivery device 3(25%) (p = ns). Mean longitudinal dissection length was 2.07 ± 1.80mm, 8(67%) appeared as flaps, 4(33%) as cavities. Morphometric parameters were comparable in both groups. Detailed OCT assessment of stent edge dissections was possible, which revealed no large differences using the Xposition delivery device as compared with conventional delivery device, however large studies are warranted.

  20. Biofilm Quantification on Nasolacrimal Silastic Stents After Dacryocystorhinostomy.

    PubMed

    Murphy, Jae; Ali, Mohammed Javed; Psaltis, Alkis James

    2015-01-01

    Biofilms are now recognized as potential factors in the pathogenesis of chronic inflammatory and infective diseases. The aim of this study was to examine the presence of biofilms and quantify their biomass on silastic nasolacrimal duct stents inserted after dacryocystorhinostomy (DCR). A prospective study was performed on a series of patients undergoing DCR with O'Donoghue stent insertion. After removal, the stents were subjected to biofilm analysis using standard protocols of confocal laser scanning microscopy (CLSM) and scanning electron microscopy. These stents were compared against negative controls and positive in vitro ones established using Staphylococcus aureus strain ATCC 25923. Biofilm quantification was performed using the COMSTAT2 software and the total biofilm biomass was calculated. A total of nine consecutive patient samples were included in this prospective study. None of the patients had any evidence of postoperative infection. All the stents demonstrated evidence of biofilm formation using both imaging modalities. The presence of various different sized organisms within a common exopolysaccharide matrix on CLSM suggested the existence of polymicrobial communities. The mean biomass of patient samples was 0.9385 μm³/μm² (range: 0.3901-1.9511 μm³/μm²). This is the first study to report the quantification of biomass on lacrimal stents. The presence of biofilms on lacrimal stents after DCR is a common finding but this need not necessarily translate to postoperative clinical infection.

  1. Primary Stenting of the Superficial Femoral Artery in Patients with Intermittent Claudication Has Durable Effects on Health-Related Quality of Life at 24 Months: Results of a Randomized Controlled Trial.

    PubMed

    Lindgren, Hans I V; Qvarfordt, Peter; Bergman, Stefan; Gottsäter, Anders

    2018-06-01

    Intermittent claudication (IC) is commonly caused by lesions in the superficial femoral artery (SFA), yet invasive treatment is still controversial and longer term patient-reported outcomes are lacking. This prospective randomized trial assessed the 24-month impact of primary stenting with nitinol self-expanding stents compared to best medical treatment (BMT) alone in patients with stable IC due to SFA disease on health-related quality of life (HRQoL). One hundred patients with stable IC due to SFA disease treated with BMT were randomized to either stent (n = 48) or control (n = 52) group. HRQoL assessed by Short Form 36 Health Survey (SF-36) and EuroQoL 5-dimensions (EQ5D) 24 months after treatment were primary outcome measures. Walking Impairment Questionnaire, ankle-brachial index (ABI), and walking distance were secondary outcomes. Significantly better SF-36 Physical Component Summary (P = 0.024) and physical domain scores such as Physical Function (P = 0.012), Bodily Pain (P = 0.002), General Health (P = 0.037), and EQ5D (P = 0.010) were reported in intergroup comparison between the stent and the control group. Both ABI (from 0.58 ± 0.11 to 0.85 ± 0.18; P < 0.001 in the stent group and from 0.63 ± 0.17 to 0.69 ± 0.18; P = 0.036 in the control group) and walking distance (from 170 ± 90 m to 616 ± 375 m; P < 0.001 in the stent group and from 209 ± 111 m to 331 ± 304 m; P = 0.006 in the control group) improved significantly in intragroup comparisons. In patients with IC caused by lesions in the SFA, primary stenting compared to BMT alone was associated with significant improvements in HRQoL, ABI, and walking distance durable up to 24 months of follow-up. Clinical Trial Registration http://www.clinicaltrials.gov . Unique Identifier: NCT01230229.

  2. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    PubMed

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  3. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review.

    PubMed

    Shen, Yonghua; Liu, Mingdong; Chen, Min; Li, Yunhong; Lu, Ying; Zou, Xiaoping

    2014-01-01

    Refractory chronic pancreatitis has been proposed as a challenge for endoscopists following routine single plastic stenting. However, data on the efficacy and safety of further endoscopic stenting are still controversial. The current systematic review aimed to assess the efficacy and safety of placement of fully covered self-expandable metal stent (FCSEMS) and multiple plastic stents. Databases including MEDLINE, EMBASE, the Cochrane Library, CBM, CNKI, VIP, and WANFANG Database were used to search relevant trials. Published studies were assessed by using well-defined inclusion and exclusion criteria. The process was independently performed by two investigators. A total of 5 studies provided data of 80 patients. Forest plots and publication bias were not carried out because few studies were relevant and screened studies were all case series. The technical success rate was 100% both in placement of FCSEMS and multiple plastic stents. The functional success rate after placement of FCSEMS was 100%, followed by multiple plastic stents (94.7%). Complications occurred 26.2% after FCSEMS placement, which was not described in detail in multiple plastic stents. The stent migration rate was 8.2% for FCSEMS and 10.5% for multiple plastic stents. Reintervention rate was 9.8% for FCSEMS and 15.8% for multiple plastic stents. Pain improvement rate was 85.2% for FCSEMS and 84.2% for multiple plastic stents. FCSEMS appeared to be no significant difference with multiple plastic stents in treatment of refractory chronic pancreatitis. We need to develop more investigations. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  4. Factors Influencing Decision Making for Carotid Endarterectomy versus Stenting in the Very Elderly

    PubMed Central

    Heo, Sung Hyuk; Bushnell, Cheryl D.

    2017-01-01

    As the population ages worldwide, the number of elderly patients with carotid stenosis is also increasing. There have been many large clinical trials comparing carotid endarterectomy (CAE) versus stenting, but the inclusion criteria (i.e., symptomatic or asymptomatic), stenting methods (i.e., protection device), and primary end point (i.e., the definition of myocardial infarction and follow-up period) were different between trials. Therefore, the interpretation of those results is difficult and requires attention. When it comes to age, the patients older than 80 years were excluded or stratified to a high risk group in previous landmark trials. However, a recent guideline recommended that endarterectomy may be associated with lower stroke risk compared with carotid artery stenting in patients older than 70 years with symptomatic carotid disease. The annual risk of stroke in individuals with asymptomatic carotid stenosis is about 1–3% but the risk is about 4–12% with symptomatic stenosis without carotid intervention. Although the outcome of CAE is better than that of carotid stenting in patients older than 70 years, the perioperative risk is higher in older patients. Therefore, it is important to classify high risk patients and consider underlying disability and life expectancy of very elderly patients before deciding whether to undergo a carotid intervention. In addition, we should also consider that the stroke rate with intensive medical treatment is unknown and is currently being investigated in randomized controlled trials. Intensive medical treatment includes high intensity statins, diabetes and blood pressure control, and aggressive antiplatelet treatment. The aim of this review is to report the factors that may be responsible for the variability in the treatment of carotid stenosis, particularly in the elderly population. This will allow the readers to integrate the current available evidence to individualize the treatment of carotid stenosis in this challenging population. PMID:28603515

  5. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction.

    PubMed

    Pilgrim, Thomas; Piccolo, Raffaele; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Khattab, Ahmed A; Taniwaki, Masanori; Rigamonti, Fabio; Nietlispach, Fabian; Blöchlinger, Stefan; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan

    2016-12-10

    Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.

  6. Double Kissing Crush Versus Provisional Stenting for Left Main Distal Bifurcation Lesions: DKCRUSH-V Randomized Trial.

    PubMed

    Chen, Shao-Liang; Zhang, Jue-Jie; Han, Yaling; Kan, Jing; Chen, Lianglong; Qiu, Chunguang; Jiang, Tiemin; Tao, Ling; Zeng, Hesong; Li, Li; Xia, Yong; Gao, Chuanyu; Santoso, Teguh; Paiboon, Chootopol; Wang, Yan; Kwan, Tak W; Ye, Fei; Tian, Nailiang; Liu, Zhizhong; Lin, Song; Lu, Chengzhi; Wen, Shangyu; Hong, Lang; Zhang, Qi; Sheiban, Imad; Xu, Yawei; Wang, Lefeng; Rab, Tanveer S; Li, Zhanquan; Cheng, Guanchang; Cui, Lianqun; Leon, Martin B; Stone, Gregg W

    2017-11-28

    Provisional stenting (PS) is the most common technique used to treat distal left main (LM) bifurcation lesions in patients with unprotected LM coronary artery disease undergoing percutaneous coronary intervention. The double kissing (DK) crush planned 2-stent technique has been shown to improve clinical outcomes in non-LM bifurcations compared with PS, and in LM bifurcations compared with culotte stenting, but has never been compared with PS in LM bifurcation lesions. The authors sought to determine whether a planned DK crush 2-stent technique is superior to PS for patients with true distal LM bifurcation lesions. The authors randomized 482 patients from 26 centers in 5 countries with true distal LM bifurcation lesions (Medina 1,1,1 or 0,1,1) to PS (n = 242) or DK crush stenting (n = 240). The primary endpoint was the 1-year composite rate of target lesion failure (TLF): cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Routine 13-month angiographic follow-up was scheduled after ascertainment of the primary endpoint. TLF within 1 year occurred in 26 patients (10.7%) assigned to PS, and in 12 patients (5.0%) assigned to DK crush (hazard ratio: 0.42; 95% confidence interval: 0.21 to 0.85; p = 0.02). Compared with PS, DK crush also resulted in lower rates of target vessel myocardial infarction I (2.9% vs. 0.4%; p = 0.03) and definite or probable stent thrombosis (3.3% vs. 0.4%; p = 0.02). Clinically driven target lesion revascularization (7.9% vs. 3.8%; p = 0.06) and angiographic restenosis within the LM complex (14.6% vs. 7.1%; p = 0.10) also tended to be less frequent with DK crush compared with PS. There was no significant difference in cardiac death between the groups. In the present multicenter randomized trial, percutaneous coronary intervention of true distal LM bifurcation lesions using a planned DK crush 2-stent strategy resulted in a lower rate of TLF at 1 year than a PS strategy. (Double Kissing and Double Crush Versus Provisional T Stenting Technique for the Treatment of Unprotected Distal Left Main True Bifurcation Lesions: A Randomized, International, Multi-Center Clinical Trial [DKCRUSH-V]; ChiCTR-TRC-11001213). Copyright © 2017 American College of Cardiology Foundation. All rights reserved.

  7. Safety and efficacy of the next generation Resolute Onyx zotarolimus-eluting stent: Primary outcome of the RESOLUTE ONYX core trial.

    PubMed

    Price, Matthew J; Shlofmitz, Richard A; Spriggs, Douglas J; Haldis, Thomas A; Myers, Paul; Popma Almonacid, Alexandra; Maehara, Akiko; Dauler, Michelle; Peng, Yun; Mehran, Roxana

    2017-09-23

    To assess the safety and efficacy of the novel Resolute (R-) Onyx drug-eluting stent (DES). The R-Onyx DES consists of a composite wire with an outer shell of cobalt chromium alloy and a platinum-iridium inner core to enhance radiopacity, with thinner, swaged struts and modified stent geometry compared with the predicate Resolute DES, resulting in a slightly lower total drug load in most sizes. This was a prospective, single-arm non-inferiority trial compared with a historical control. Patients with stable angina/ischemia and up to 2 de novo target lesions ≤35 mm long with reference vessel diameter (RVD) of 2.25-4.2 mm were enrolled. The primary endpoint was late lumen loss at 8-month follow-up. Propensity-score adjusted outcomes from the single-arm RESOLUTE-US trial served as the control. Seventy-five patients (85 lesions) were enrolled. Mean patient age was 66 ± 9 years, 73% were male, and 32% had diabetes. Mean lesion length was 14.28 ± 6.68 mm, mean RVD was 2.57 ± 0.48 mm, and 86% of lesions were class B2/C. In-stent late lumen loss at 8 months was 0.24 ± 0.39 mm with R-Onyx DES compared with 0.36 ± 0.52 mm with Resolute DES (P < 0.001 for noninferiority, P = 0.029 for superiority). At 8 months, clinically driven target lesion revascularization occurred in 3 patients (4.0%) and target lesion failure occurred in 5 patients (6.7%). In-stent late lumen loss is non-inferior, and appears to be superior, with the thin-strut novel composite wire R-Onyx DES compared with Resolute DES. Continued evolution of stent design can improve angiographic outcomes in complex lesions, even in the current era of next-generation DES. © 2017 Wiley Periodicals, Inc.

  8. DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity (DUTCH PEERS): rationale and study design of a randomized multicenter trial in a Dutch all-comers population.

    PubMed

    Tandjung, Kenneth; Basalus, Mounir W Z; Sen, Hanim; Jessurun, Gillian A J; Danse, Peter W; Stoel, Martin; Linssen, Gerard C M; Derks, Anita; van Loenhout, Ton T; Nienhuis, Mark B; Hautvast, Raymond W M; von Birgelen, Clemens

    2012-04-01

    Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed. Promus Element (Boston Scientific, Natick, MA) and Resolute Integrity (Medtronic Vascular, Santa Rosa, CA) are 2 novel third-generation DES for which limited clinical data are available. Accordingly, we designed the current multicenter study to investigate in an all-comers population whether the clinical outcome is similar after stenting with Promus Element versus Resolute Integrity. DUTCH PEERS is a multicenter, prospective, single-blinded, randomized trial in a Dutch all-comers population. Patients with all clinical syndromes who require percutaneous coronary interventions with DES implantation are eligible. In these patients, the type of DES implanted will be randomized in a 1:1 ratio between Resolute Integrity versus Promus Element. The trial is powered based on a noninferiority hypothesis. For each stent arm, 894 patients will be enrolled, resulting in a total study population of 1,788 patients. The primary end point is the incidence of target vessel failure at 1-year follow-up. DUTCH PEERS is the first randomized multicenter trial with a head-to-head comparison of Promus Element and Resolute Integrity to investigate the safety and efficacy of these third-generation DES. Copyright © 2012 Mosby, Inc. All rights reserved.

  9. Carotid Endarterectomy: Current Concepts and Practice Patterns

    PubMed Central

    Saha, Sibu P.; Saha, Subhajit; Vyas, Krishna S.

    2015-01-01

    Background Stroke is the number one cause of disability and third leading cause of death among adults in the United States. A major cause of stroke is carotid artery stenosis (CAS) caused by atherosclerotic plaques. Randomized trials have varying results regarding the equivalence and perioperative complication rates of stents versus carotid endarterectomy (CEA) in the management of CAS. Objectives We review the evidence for the current management of CAS and describe the current concepts and practice patterns of CEA. Methods A literature search was conducted using PubMed to identify relevant studies regarding CEA and stenting for the management of CAS. Results The introduction of CAS has led to a decrease in the percentage of CEA and an increase in the number of CAS procedures performed in the context of all revascularization procedures. However, the efficacy of stents in patients with symptomatic CAS remains unclear because of varying results among randomized trials, but the perioperative complication rates exceed those found after CEA. Conclusions Vascular surgeons are uniquely positioned to treat carotid artery disease through medical therapy, CEA, and stenting. Although data from randomized trials differ, it is important for surgeons to make clinical decisions based on the patient. We believe that CAS can be adopted with low complication rate in a selected subgroup of patients, but CEA should remain the standard of care. This current evidence should be incorporated into practice of the modern vascular surgeon. PMID:26417192

  10. Design of the exhale airway stents for emphysema (EASE) trial: an endoscopic procedure for reducing hyperinflation

    PubMed Central

    2011-01-01

    Background Airway Bypass is a catheter-based, bronchoscopic procedure in which new passageways are created that bypass the collapsed airways, enabling trapped air to exit the lungs. The Exhale Airway Stents for Emphysema (EASE) Trial was designed to investigate whether Exhale® Drug-Eluting Stents, placed in new passageways in the lungs, can improve pulmonary function and reduce breathlessness in severely hyperinflated, homogeneous emphysema patients (NCT00391612). Methods/Design The multi-center, randomized, double-blind, sham-controlled trial design was posted on http://www.clinicaltrials.gov in October 2006. Because Bayesian statistics are used for the analysis, the proposed enrollment ranged from 225 up to 450 subjects at up to 45 institutions. Inclusion criteria are: high resolution CT scan with evidence of homogeneous emphysema, post-bronchodilator pulmonary function tests showing: a ratio of FEV1/FVC < 70%, FEV1≤50% of predicted or FEV1 < 1 liter, RV/TLC≥0.65 at screening, marked dyspnea score ≥2 on the modified Medical Research Council scale of 0-4, a smoking history of at least 20 pack years and stopped smoking for at least 8 weeks prior to enrollment. Following 16 to 20 supervised pulmonary rehabilitation sessions, subjects were randomized 2:1 to receive either a treatment (Exhale® Drug-Eluting Stent) or a sham bronchoscopy. A responder analysis will evaluate the co-primary endpoints of an FVC improvement ≥12% of the patient baseline value and modified Medical Research Council dyspnea scale improvement (reduction) ≥1 point at the 6-month follow-up visit. Discussion If through the EASE Trial, Airway Bypass is shown to improve pulmonary function and reduce dyspnea while demonstrating an acceptable safety profile, then homogeneous patients will have a minimally invasive treatment option with meaningful clinical benefit. Trial Registration ClinicalTrials.gov: NCT00391612 PMID:21214899

  11. Comparison of partially covered nitinol stents with partially covered stainless stents as a historical control in a multicenter study of distal malignant biliary obstruction: the WATCH study.

    PubMed

    Isayama, Hiroyuki; Mukai, Tsuyoshi; Itoi, Takao; Maetani, Iruru; Nakai, Yousuke; Kawakami, Hiroshi; Yasuda, Ichiro; Maguchi, Hiroyuki; Ryozawa, Shomei; Hanada, Keiji; Hasebe, Osamu; Ito, Kei; Kawamoto, Hirofumi; Mochizuki, Hitoshi; Igarashi, Yoshinori; Irisawa, Atsushi; Sasaki, Tamito; Togawa, Osamu; Hara, Taro; Kamada, Hideki; Toda, Nobuo; Kogure, Hirofumi

    2012-07-01

    Covered self-expandable metal stents (CSEMSs) were developed to prevent tumor ingrowth, but stent migration is one of the problems with CSEMSs. To evaluate a new, commercially available CSEMS with flared ends and low axial force compared with a commercially available CSEMS without the anti-migration system and high axial force. Multicenter, prospective study with a historical cohort. Twenty Japanese referral centers. This study involved patients with unresectable distal malignant biliary obstruction. Placement of a new, commercially available, partially covered SEMS. Recurrent biliary obstruction rate, time to recurrent biliary obstruction, stent-related complications, survival. Between April 2009 and March 2010, 141 patients underwent partially covered nitinol stent placement, and between May 2001 and January 2007, 138 patients underwent placement of partially covered stainless stents as a historical control. The silicone cover of the partially covered nitinol stents prevented tumor ingrowth. There were no significant differences in survival (229 vs 219 days; P = .250) or the rate of recurrent biliary obstruction (33% vs 38%; P = .385) between partially covered nitinol stents and partially covered stainless stents. Stent migration was less frequent (8% vs 17%; P = .019), and time to recurrent biliary obstruction was significantly longer (373 vs 285 days; P = .007) with partially covered nitinol stents. Stent removal was successful in 26 of 27 patients (96%). Nonrandomized, controlled trial. Partially covered nitinol stents with an anti-migration system and less axial force demonstrated longer time to recurrent biliary obstruction with no tumor ingrowth and less stent migration. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Esophageal stent placement as a therapeutic option for iatrogenic esophageal perforation in children.

    PubMed

    Ahmad, Alsafadi; Wong Kee Song, Louis M; Absah, Imad

    2016-01-01

    Iatrogenic esophageal perforation (IEP) is a potentially serious adverse event of interventional endoscopy. The approach to IEP varies from surgical repair for large perforations to conservative treatment for small contained perforations. We report a case of an 18-month-old girl with congenital esophageal stenosis suffering a large esophageal perforation after a trial of stricture dilatation, which was successfully managed by the placement of fully covered stent. Hence, in selected cases, esophageal stent placement is a feasible alternative to invasive surgery in managing IEP.

  13. Newly designed "pieced" stent in a rabbit model of benign esophageal stricture.

    PubMed

    Liu, Jin; Shang, Liang; Liu, Ji-Yong; Qin, Cheng-Yong

    2015-07-28

    To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture. Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation. Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups. The control group (n = 15) was implanted with a conventional stent, and the study group (n = 15) was implanted with a detachable "pieced" stent. The study stent (30 mm in length, 10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines. The stent was collapsed by pulling the suture lines out of the mesh. Two weeks after stricture formation, endoscopic placement of a conventional stent or the new stent was performed. Endoscopic extraction was carried out four weeks later. The extraction rate, ease of extraction, migration, complications, and survival were evaluated. Stent migration occurred in 3/15 (20%) animals in the control group and 2/15 (13%) animals in the study group; the difference between the two groups was not statistically significant. At the end of four weeks, the remaining stents were successfully extracted with the endoscope in 100% (11/11) of the animals in the study group, and 60% (6/10) of the animals in the control group; this difference was statistically significant (P < 0.05). There was no difference in the mean number of follow-up days between the control and study groups (25.33 vs 25.85). Minor bleeding was reported in five cases in the study group and four in the control group. There were no severe complications directly associated with stent implantation or extraction in either of the two groups. In this experimental protocol of benign esophageal strictures, the novel "pieced" stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent.

  14. Advances in Clinical Cardiology 2016: A Summary of the Key Clinical Trials.

    PubMed

    Gray, Alastair; McQuillan, Conor; Menown, Ian B A

    2017-07-01

    The findings of many new cardiology clinical trials over the last year have been published or presented at major international meetings. This paper aims to describe and place in context a summary of the key clinical trials in cardiology presented between January and December 2016. The authors reviewed clinical trials presented at major cardiology conferences during 2016 including the American College of Cardiology (ACC), European Association for Percutaneous Cardiovascular Interventions (EuroPCR), European Society of Cardiology (ESC), European Association for the Study of Diabetes (EASD), Transcatheter Cardiovascular Therapeutics (TCT), and the American Heart Association (AHA). Selection criteria were trials with a broad relevance to the cardiology community and those with potential to change current practice. A total of 57 key cardiology clinical trials were identified for inclusion. Here we describe and place in clinical context the key findings of new data relating to interventional and structural cardiology including delayed stenting following primary angioplasty, contrast-induced nephropathy, management of jailed wires, optimal duration of dual antiplatelet therapy (DAPT), stenting vs bypass for left main disease, new generation stents (BioFreedom, Orsiro, Absorb), transcatheter aortic valve implantation (Edwards Sapien XT, transcatheter embolic protection), and closure devices (Watchman, Amplatzer). New preventative cardiology data include trials of bariatric surgery, empagliflozin, liraglutide, semaglutide, PCSK9 inhibitors (evolocumab and alirocumab), and inclisiran. Antiplatelet therapy trials include platelet function monitoring and ticagrelor vs clopidogrel for peripheral vascular disease. New data are also presented in fields of heart failure (sacubitril/valsartan, aliskiren, spironolactone), atrial fibrillation (rivaroxaban in patients undergoing coronary intervention, edoxaban in DC cardioversion), cardiac devices (implantable cardioverter defibrillator in non-ischemic cardiomyopathy), and electrophysiology (cryoballoon vs radiofrequency ablation). This paper presents a summary of key clinical cardiology trials during the past year and should be of practical value to both clinicians and cardiology researchers.

  15. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis.

    PubMed

    Li, Jinjin; Li, Tong; Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19-4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05-10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57-1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94-1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56-0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12-0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03-3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54-34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36-4.50; p = 0.003, I2 = 0%). Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary obstruction due to their removability.

  16. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    PubMed

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  17. Long-term results of a sirolimus-eluting stent with biodegradable polymer (RAPSTROM™) in de novo coronary stenoses.

    PubMed

    Figini, Filippo; Manjunath, Chaman Nadish; Srinivas, Balaji Chandra; Sadananda, Kanvar Sarat; Sreedharan, Madhu; Fischer, Louie; Pillai, Ramakrishna; Varghese, Kiron; Gopal, Ajay K; Nagesh, Chamarajnagar Mahadevappa; Sheiban, Imad

    2017-10-07

    To report long-term results of a novel sirolimus-eluting stent with biodegradable polymer BACKGROUND: Newer generation drug-eluting stents are characterized by thin struts, improved platform design and highly biocompatible polymer carrying the antiproliferative drug. The RapstromTM stent, sharing these features, showed promising outcomes in preclinical models and in a first-in-man trial. The present study is a multicenter, non-randomized post-market registry, including patients with de novo coronary artery disease treated with implantation of one or more Rapstrom stents. Primary endpoint of the study was the rate of major adverse cardiac events (MACE) at three-year follow-up. 1073 patients were enrolled, with a high prevalence of diabetes (35%) and acute coronary syndrome at presentation (82%); at three-year follow up, MACE rate was 14.8%, with a low incidence of definite or probable stent thrombosis (0.75%). These data confirm the good clinical performance of the Rapstrom stent, supporting the concept that the combination of thin struts and biodegradable polymer is associated with positive clinical outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Immediate and late clinical and angiographic outcomes after GFX coronary stenting: is high-pressure balloon dilatation necessary?

    PubMed

    Park, S W; Hong, M K; Lee, C W; Kim, J J; Park, H K; Cho, G Y; Kang, D H; Song, J K; Park, S J

    2000-08-01

    The GFX stent is a balloon-expandable stent made of sinusoidal element of stainless steel. The adjunct high-pressure balloon dilatations were usually recommended in routine stenting procedure. The aim of this study was to evaluate the immediate and long-term clinical and angiographic outcomes and to investigate the necessity of high-pressure balloon dilatation during GFX stenting. In all, 172 consecutive patients underwent single 12 or 18 mm GFX stent implantation in 188 native coronary lesions. Two types of stenting technique were used: (1) stent size of a final stent-to-artery ratio of 1:1 (inflation pressure > 10 atm, high-pressure group), and (2) stent size of 0.5 mm bigger than reference vessel (inflation pressure < or = 10 atm, low-pressure group). The adjunct high-pressure balloon dilatations were performed only in cases of suboptimal results. The adjunct high-pressure balloon dilatation was required in 11 of 83 lesions (13%) in the high-pressure group and in 7 of 105 lesions (7%) in the low-pressure group (p = 0.203). Procedural success rate was 100%. There were no significant differences of in-hospital and long-term clinical events between the two groups. The overall angiographic restenosis rate was 17.7%; 18.4% in the high-pressure group and 17.1% in the low-pressure group (p = 0.991). The GFX stent is a safe and effective device with a high procedural success rate and favorable late clinical outcome for treatment of native coronary artery disease. Further randomized trials may be needed to compare stenting techniques in GFX stent implantation.

  19. Long-term safety and performance of the orbital atherectomy system for treating calcified coronary artery lesions: 5-Year follow-up in the ORBIT I trial.

    PubMed

    Bhatt, Parloop; Parikh, Parth; Patel, Apurva; Chag, Milan; Chandarana, Anish; Parikh, Roosha; Parikh, Keyur

    2015-06-01

    The ORBIT I trial, a first-in-man study, was conducted to evaluate the safety and performance of the orbital atherectomy system (OAS) in treating de novo calcified coronary lesions. Fifty patients were enrolled between May and July 2008 based on several criteria, and were treated with the OAS followed by stent placement. The safety and performance of the OAS were evaluated by procedural success, device success, and overall major adverse cardiovascular event (MACE) rates, including cardiac death, myocardial infarction (MI) and need for target lesion revascularization (TLR). Our institution enrolled and treated 33 of the 50 patients and continued follow-up for 5 years. Average age was 54 years and 91% were males. Mean lesion length was 15.9 mm. Device success was 100%, and average number of orbital atherectomy devices (OAD) used per patient was 1.3. Stents were placed directly after OAS in 31/32 patients (96.9%). All stents (average stent per lesion 1.1) were successfully deployed with 0.3% residual stenosis. The overall cumulative MACE rate was 6.1% in-hospital, 9.1% at 30 days, 12.1% at 6 months, 15.2% at 2 years, 18.2% at 3 years and 21.2% at 5 years (4 total cardiac deaths). None of the patients had Q-wave MIs. Angiographic complications were observed in 5 patients. No flow/slow flow due to distal embolization was observed. The ORBIT I trial suggests that OAS treatment continues to offer a safe and effective method to change compliance of calcified coronary lesions to facilitate optimal stent placement in these difficult-to-treat patients. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  20. A novel stent inflation protocol improves long-term outcomes compared with rapid inflation/deflation deployment method.

    PubMed

    Vallurupalli, Srikanth; Kasula, Srikanth; Kumar Agarwal, Shiv; Pothineni, Naga Venkata K; Abualsuod, Amjad; Hakeem, Abdul; Ahmed, Zubair; Uretsky, Barry F

    2017-08-01

    High-pressure inflation for coronary stent deployment is universally performed. However, the duration of inflation is variable and does not take into account differences in lesion compliance. We developed a standardized "pressure optimization protocol" (POP) using inflation pressure stability rather than an arbitrary inflation time or angiographic balloon appearance for stent deployment. Whether this approach improves long-term outcomes is unknown. 792 patients who underwent PCI using either rapid inflation/deflation (n = 376) or POP (n = 416) between January 2009 and March 2014 were included. Exclusion criteria included PCI for acute myocardial infarction, in-stent restenosis, chronic total occlusion, left main, and saphenous vein graft lesions. Primary endpoint was target vessel failure [TVF = combined end point of target vessel revascularization (TVR), myocardial infarction, and cardiac death]. Outcomes were analyzed in the entire cohort and in a propensity analysis. Stent implantation using POP with a median follow-up of 1317 days was associated with lower TVF compared with rapid inflation/deflation (10.1 vs. 17.8%, P < 0.0001). This difference was driven by a decrease in TVR (7 vs. 10.6%, P = 0.0016) and cardiac death (2.9 vs. 5.8%, P = 0.017) while there was no difference in myocardial infarction (1 vs. 1.9%, P = 0.19). In the Cox regression model, deployment using POP was the only independent predictor of reduced TVF (HR 0.43; 0.29-0.64; P < 0.0001). In the propensity analysis (330 patients per group) TVF remained lower with POP vs. rapid inflation/deflation (10 vs. 18%, P < 0.0001). Stent deployment using POP led to reduced TVF compared to rapid I/D. These results recommend this method to improve long-term outcomes. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  1. The Effect of Cilostazol on the Angiographic Outcome of Drug-Eluting Coronary Stents Angiographic Analysis of the CILON-T (Influence of CILostazol-Based Triple Antiplatelet Therapy ON Ischemi Complication after Drug-Eluting StenT Implantation) Trial.

    PubMed

    Suh, Jung-Won; Lee, Seung-Pyo; Park, KyungWoo; Kang, Hyun-Jae; Koo, Bon-Kwon; Cho, Young-Seok; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju; Rha, Seung-Woon; Bae, Jang-Ho; Kwon, Taek-Geun; Bae, Jang-Whan; Cho, Myeong-Chan; Kim, Hyo-Soo

    2017-12-12

    It is not clear if anti-restonotic effect of cilostazol is consistent for different types of drug-eluting stents (DES).The purpose of this study was to compare the anti-proliferative effect of cilostazol between DAT and TAT with consideration of confounding influences of DES type.Nine hundred and fifteen patients were randomized to either dual antiplatelet therapy (DAT; aspirin and clopidogrel) or triple antiplatelet therapy (TAT; aspirin, clopidogrel, and cilostazol) in the previous CILON-T trial. After excluding 70 patients who received both or neither stents, we analyzed 845 patients who received exclusively PES or ZES, and compared in-stent late loss at 6 months between both antiplatelet regimens (DAT versus TAT).Baseline angiographic and clinical characteristics were similar between the DAT (656 lesions in 425 patients) and the TAT group (600 lesions in 420 patients). The 6-month follow-up angiography was completed in 745 patients (88.2%). Quantitative coronary angiography showed that TAT significantly reduced in-stent late loss (DAT 0.62 ± 0.62 mm versus TAT 0.54 ± 0.49 mm, P = 0.015). Stent type, diabetes or lesion length did not interact with difference of late loss. However, reduction of late loss by cilostazol did not lead to a significant reduction in the rate of target lesion revascularization (TLR) (DAT 7.8% versus TAT 6.9%, P = 0.69) due to a nonlinear relationship found between late loss and TLR.The TAT group showed less in-stent late loss as compared to the DAT group. This was consistently observed regardless of DES type, lesion length, or diabetic status. However, reduction of late loss by cilostazol did not lead to a significant reduction in TLR.

  2. Randomised comparison of drug-eluting versus bare-metal stenting in patients with non-ST elevation myocardial infarction

    PubMed Central

    Remkes, Wouter S; Badings, Erik A; Hermanides, Renicus S; Rasoul, Saman; Dambrink, Jan-Henk E; Koopmans, Petra C; The, Salem HK; Ottervanger, Jan Paul; Gosselink, A T Marcel; Hoorntje, Jan CA; Suryapranata, Harry; van 't Hof, Arnoud WJ

    2016-01-01

    Objective The superiority of drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ST elevation myocardial infarction (STEMI) is well studied; however, randomised data in patients with non-ST elevation myocardial infarction (NSTEMI) are lacking. The objective of this study was to investigate whether stenting with everolimus-eluting stents (EES) safely reduces restenosis in patients with NSTEMI as compared to BMS. Methods ELISA-3 patients were asked to participate in the angiographic substudy and were randomised to DE (Xience V) or BM (Vision) stenting (ELISA-3 group). The primary end point was minimal luminal diameter (MLD) at 9-month follow-up angiography. In addition, 296 patients with NSTEMI who were excluded or did not want to participate in the ELISA-3 trial (RELI group) were randomised to DE or BM stenting and underwent clinical follow-up only (major adverse cardiac events (MACE), stent thrombosis (ST)). A pooled analysis was performed to assess an effect on clinical outcome. Results 178 of 540 ELISA-3 patients participated in the angiographic substudy. MLD at 9 months angiography was 2.37±0.63 mm (DES) versus 1.84±0.62 mm (BMS), p<0.001. Binary restenosis occurred in 1.9% in the DES group versus 16.7% in the BMS group (RR 0.11, 95% CI 0.02 to 0.84, p=0.007). In the pooled analysis, the incidence of MACE, target vessel revascularisation and ST at 2 years follow-up in the DES versus BMS group was 12.5% versus 16.0% (p=0.28), 4.0% versus 10.4% (p=0.009) and 1.3% versus 3.0% (p=0.34), respectively. Conclusions In patients with NSTEMI, use of EES is safe and decreases both angiographic and clinical restenosis as compared to BMS http://www.isrctn.com/search?q=39230163. Trial registration number 39230163; Post-results. PMID:27933192

  3. Stenting and medical therapy for atherosclerotic renal-artery stenosis.

    PubMed

    Cooper, Christopher J; Murphy, Timothy P; Cutlip, Donald E; Jamerson, Kenneth; Henrich, William; Reid, Diane M; Cohen, David J; Matsumoto, Alan H; Steffes, Michael; Jaff, Michael R; Prince, Martin R; Lewis, Eldrin F; Tuttle, Katherine R; Shapiro, Joseph I; Rundback, John H; Massaro, Joseph M; D'Agostino, Ralph B; Dworkin, Lance D

    2014-01-02

    Atherosclerotic renal-artery stenosis is a common problem in the elderly. Despite two randomized trials that did not show a benefit of renal-artery stenting with respect to kidney function, the usefulness of stenting for the prevention of major adverse renal and cardiovascular events is uncertain. We randomly assigned 947 participants who had atherosclerotic renal-artery stenosis and either systolic hypertension while taking two or more antihypertensive drugs or chronic kidney disease to medical therapy plus renal-artery stenting or medical therapy alone. Participants were followed for the occurrence of adverse cardiovascular and renal events (a composite end point of death from cardiovascular or renal causes, myocardial infarction, stroke, hospitalization for congestive heart failure, progressive renal insufficiency, or the need for renal-replacement therapy). Over a median follow-up period of 43 months (interquartile range, 31 to 55), the rate of the primary composite end point did not differ significantly between participants who underwent stenting in addition to receiving medical therapy and those who received medical therapy alone (35.1% and 35.8%, respectively; hazard ratio with stenting, 0.94; 95% confidence interval [CI], 0.76 to 1.17; P=0.58). There were also no significant differences between the treatment groups in the rates of the individual components of the primary end point or in all-cause mortality. During follow-up, there was a consistent modest difference in systolic blood pressure favoring the stent group (-2.3 mm Hg; 95% CI, -4.4 to -0.2; P=0.03). Renal-artery stenting did not confer a significant benefit with respect to the prevention of clinical events when added to comprehensive, multifactorial medical therapy in people with atherosclerotic renal-artery stenosis and hypertension or chronic kidney disease. (Funded by the National Heart, Lung and Blood Institute and others; ClinicalTrials.gov number, NCT00081731.).

  4. Randomized multicentre trial comparing external and internal pancreatic stenting during pancreaticoduodenectomy.

    PubMed

    Jang, J-Y; Chang, Y R; Kim, S-W; Choi, S H; Park, S J; Lee, S E; Lim, C-S; Kang, M J; Lee, H; Heo, J S

    2016-05-01

    There is no consensus on the best method of preventing postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD). This multicentre, parallel group, randomized equivalence trial investigated the effect of two ways of pancreatic stenting after PD on the rate of POPF. Patients undergoing elective PD or pylorus-preserving PD with duct-to-mucosa pancreaticojejunostomy were enrolled from four tertiary referral hospitals. Randomization was stratified according to surgeon with a 1 : 1 allocation ratio to avoid any related technical factors. The primary endpoint was clinically relevant POPF rate. Secondary endpoints were nutritional index, remnant pancreatic volume, long-term complications and quality of life 2 years after PD. A total of 328 patients were randomized to the external (164 patients) or internal (164) stent group between August 2010 and January 2014. The rates of clinically relevant POPF were 24·4 per cent in the external and 18·9 per cent in the internal stent group (risk difference 5·5 per cent). As the 90 per cent confidence interval (-2·0 to 13·0 per cent) did not fall within the predefined equivalence limits (-10 to 10 per cent), the clinically relevant POPF rates in the two groups were not equivalent. Similar results were observed for patients with soft pancreatic texture and high fistula risk score. Other postoperative outcomes were comparable between the two groups. Five stent-related complications occurred in the external stent group. Multivariable analysis revealed that soft pancreatic texture, non-pancreatic disease and high body mass index (23·3 kg/m 2 or above) predicted clinically relevant POPF. External stenting after PD was associated with a higher rate of clinically relevant POPF than internal stenting. Registration number: NCT01023594 (https://www.clinicaltrials.gov). © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.

  5. Randomized trial in malignant biliary obstruction: Plastic vs partially covered metal stents

    PubMed Central

    Moses, Peter L; AlNaamani, Khalid M; Barkun, Alan N; Gordon, Stuart R; Mitty, Roger D; Branch, M Stanley; Kowalski, Thomas E; Martel, Myriam; Adam, Viviane

    2013-01-01

    AIM: To compare efficacy and complications of partially covered self-expandable metal stent (pcSEMS) to plastic stent (PS) in patients treated for malignant, infrahilar biliary obstruction. METHODS: Multicenter prospective randomized clinical trial with treatment allocation to a pcWallstent® (SEMS) or a 10 French PS. Palliative patients aged ≥ 18, for infrahilar malignant biliary obstruction and a Karnofsky performance scale index > 60% from 6 participating North American university centers. Primary endpoint was time to stent failure, with secondary outcomes of death, adverse events, Karnofsky performance score and short-form-36 scale administered on a three-monthly basis for up to 2 years. Survival analyses were performed for stent failure and death, with Cox proportional hazards regression models to determine significant predictive characteristics. RESULTS: Eighty-five patients were accrued over 37 mo, 42 were randomized to the SEMS group and 83 patients were available for analyses. Time to stent failure was 385.3 ± 52.5 d in the SEMS and 153.3 ± 19.8 d in the PS group, P = 0.006. Time to death did not differ between groups (192.3 ± 23.4 d for SEMS vs 211.5 ± 28.0 d for PS, P = 0.70). The only significant predictor was treatment allocation, relating to the time to stent failure (P = 0.01). Amongst other measured outcomes, only cholangitis differed, being more common in the PS group (4.9% vs 24.5%, P = 0.029). The small number of patients in follow-up limits longitudinal assessments of performance and quality of life. From an initially planned 120 patients, only 85 patients were recruited. CONCLUSION: Partially covered SEMS result in a longer duration till stent failure without increased complication rates, yet without accompanying measurable benefits in survival, performance, or quality of life. PMID:24379581

  6. Randomized comparison of deliverability and in-hospital complications in implantation of BxSonic(R), Express(R), and Flexmaster(R) coronary stents.

    PubMed

    Thuesen, Leif; Galløe, Anders; Thayssen, Per; Rasmussen, Klaus; Kelbæk, Henning; Lassen, Jens Flensted; Hansen, Peter Riis; Pedersen, Knud Erik; Ravkilde, Jan; Helquist, Steffen; Abildgaard, Ulrik; Andersen, Henning Rud; Bøtker, Hans Erik; Kristensen, Steen Dalby; Hjort, Jacob; Krusell, Lars Romer

    2005-11-01

    To compare deliverability and in-hospital complications in implantation of BxSonic(R), Express(R), and Flexmaster(R) coronary stents in a randomized multicenter trial in five Danish interventional centres. Patients with planned stenting of at least one stenotic lesion in a native coronary artery were included in the study. There were 494 (664) patients (treated lesions) in the BxSonic(R), 499 (657) in the Express(R) and 500 (658) in the Flexmaster(R) groups. The groups were well matched with regard to age, sex, diabetes, smoking, hypercholesterolemia, hypertension, indication for PCI and coronary artery lesion complexity. The study stents were implanted with or without predilatation according to ordinary -clinical practice.Rates of successful stent implantation and in-hospital stent thrombosis, re-intervention, non-fatal myocardial infarction or death. The BxSonic(R), Express(R) and Flexmaster(R) stents were successfully implanted in 92,2%, 89,3% and 91,6% of all lesions (ns). There were no in-hospital deaths and the rates of in-hospital complications were similar in the three stent groups. We found similar deliverability and in-hospital complication rates of the BxSonic(R), Express(R) and Flexmaster(R) stents.

  7. A new fully covered metal stent with anti-migration features for the treatment of malignant dysphagia.

    PubMed

    Walter, Daisy; van den Berg, Maarten W; van Hooft, Jeanin E; Boot, Henk; Scheffer, Robert C H; Vleggaar, Frank P; Siersema, Peter D

    2014-12-01

    A new esophageal stent with two anti-migration features was developed to minimize migration. The aim of this study was to evaluate the clinical efficacy and safety of this stent in patients with malignant dysphagia. A total of 40 patients with dysphagia due to a malignant obstruction of the esophagus were prospectively enrolled in this cohort study. Stent placement was technically successful in 39 patients (98 %). The median dysphagia-free time after stent placement was 220 days (95 % confidence interval 94 - 345 days). Nine patients (23 %) experienced recurrent dysphagia due to tissue overgrowth (n = 2), stent fracture (n = 1), and partial (n = 5) or complete (n = 1) stent migration. A total of 16 serious adverse events occurred in 14 patients (36 %), with hemorrhage (n = 3) and severe nausea or vomiting (n = 3) being the most common causes. This new stent design was effective for the palliation of malignant dysphagia and had a low rate of recurrent dysphagia. However, despite the anti-migration features, stent migration was still a major cause of recurrent dysphagia. Furthermore, treatment was associated with a high adverse event rate. Dutch Trial Registration (NTR 3313). © Georg Thieme Verlag KG Stuttgart · New York.

  8. Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents

    PubMed Central

    Akinapelli, Abhilash; Chen, Jack P.; Roy, Kristine; Donnelly, Joseph; Dawkins, Keith; Huibregtse, Barbara; Hou, Dongming

    2017-01-01

    Drug-eluting stents (DES) have been shown to significantly reduce clinical and angiograph-ic restenosis compared to bare metal stents (BMS). The polymer coatings on DES elute antiproliferative drugs to inhibit intimal proliferation and prevent restenosis after stent implantation. Permanent poly-mers which do not degrade in vivo may increase the likelihood of stent-related delayed arterial healing or polymer hypersensitivity. In turn, these limitations may contribute to an increased risk of late clinical events. Intuitively, a polymer which degrades after completion of drug release, leaving an inert metal scaffold in place, may improve arterial healing by removing a chronic source of inflammation, neoath-erosclerosis, and/or late thrombosis. In this way, a biodegradable polymer may reduce late ischemic events. Additionally, improved healing after stent implantation could reduce the requirement for long-term dual antiplatelet therapy and the associated risk of bleeding and cost. This review will focus on bioabsorbable polymer-coated DES currently being evaluated in clinical trials.

  9. Monitoring the Wall Mechanics During Stent Deployment in a Vessel

    PubMed Central

    Steinert, Brian D.; Zhao, Shijia; Gu, Linxia

    2012-01-01

    Clinical trials have reported different restenosis rates for various stent designs1. It is speculated that stent-induced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis2-7. This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface8,9. As a mesh stent is deployed into a latex vessel with a random contrasting pattern sprayed or drawn on its outer surface, the surface strain is recorded at every instant of the deformation. The calculated strain distributions can then be used to understand the local lesion response, validate the computational models, and formulate hypotheses for further in vivo study. PMID:22588353

  10. Single Versus Double Ureteral Stent Placement After Laser Endoureterotomy for the Management of Benign Ureteral Strictures: A Randomized Clinical Trial.

    PubMed

    Ibrahim, Hamdy M; Mohyelden, Khaled; Abdel-Bary, Ahmed; Al-Kandari, Ahmed M

    2015-10-01

    Endoureterotomy is a viable option for treating patients with benign ureteral stricture. We compared the efficacy and safety of double versus single ureteral stent placement after laser endoureterotomy. This study included 55 patients with benign ureteral strictures; all patients underwent retrograde laser endoureterotomy. Patients were randomized either to single or double ureteral stents. Single stents were placed in 27 ureters while double stents were placed in 28 ureters. The stent diameter used was 7 F, and stents were indwelling for 8 weeks. Imaging was performed 1 month after stent removal and repeated regularly every 3 months. Clinical characteristics, operative results, and functional outcomes were compared for strictures managed in both groups. Success was evaluated both subjectively and objectively. Fifty-five patients with a mean age of 46 (16-75) years had benign ureteral strictures; the mean stricture length was 1.92 (1-3) cm. The mean follow-up was 25.7 (9-42) months. The overall success rate was 67.3% (37 patients) with no radiologic evidence of obstruction, 6 (10.9%) patients showed symptomatic improvement while 12 (21.8%) patients underwent surgical reconstruction. Success was significantly higher for ureteral strictures (>1.5 cm) managed with double stent placement (82.4%), compared with single stent placement (38.9%) with a P value of 0.009. Double stent placement of the ureter after laser endoureterotomy achieved a higher success rate compared with single stent placement in cases of benign ureteral strictures. Although ureteral strictures (≤1.5 cm) achieved better outcome after laser endoureterotomy, strictures (>1.5 cm) favored better with double stent versus single stent placement.

  11. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution

    PubMed Central

    Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    2017-01-01

    IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P < .001). Given the prespecified noninferiority margin of −15%, the null hypothesis that cSEMS is less effective than plastic stents was rejected. The mean number of ERCPs to achieve resolution was lower for cSEMS (2.14) vs plastic (3.24; mean difference, 1.10; 95% CI, 0.74 to 1.46; P < .001). CONCLUSIONS AND RELEVANCE Among patients with benign biliary strictures and a bile duct diameter 6 mm or more in whom the covered metallic stent would not overlap the cystic duct, cSEMS were not inferior to multiple plastic stents after 12 months in achieving stricture resolution. Metallic stents should be considered an appropriate option in patients such as these. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01221311 PMID:27002446

  12. Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahlhelm, Frank, E-mail: frah1@gmx.de; Kaufmann, Ralf, E-mail: ralf.kaufmann@vascomed.d; Ahlhelm, Dirk, E-mail: ahlhelmd@gmx.de

    We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular interventionmore » as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.« less

  13. Establishing an endovascular carotid stent program.

    PubMed

    Raabe, Rod; Chong, Brian

    2004-12-01

    FDA approval of carotid stent and distal protection devices has transformed carotid artery stenting (CAS) from an investigational procedure to a practical application. Recent approval by the Center for Medicare Services (CMS) has ensured that CAS will be a part of everyday practice throughout the country. To establish a competitive endovascular carotid stent program, one needs to develop an effective strategy. The key to success is substance and service. A high-quality clinical program with excellent communication between the patient and referring physician is essential. You must first get access to the patient by establishing a clinical practice. As a radiologist, you have the advantage of gaining access by identifying appropriate patients through noninvasive vascular labs, CTA, and MRA. An algorithm-driven evaluation and treatment protocol with good pre- and postoperative care, along with a quality assurance program, will ensure that your carotid stent program has substance and delivers optimal service. With good planning, you will have a firm clinical foundation for treatment of carotid artery stenosis in your community. Putting all of the ingredients together will ensure a successful carotid endovascular program.

  14. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.

    PubMed

    Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma

    2015-07-01

    The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.

  15. Validation of an image registration and segmentation method to measure stent graft motion on ECG-gated CT using a physical dynamic stent graft model

    NASA Astrophysics Data System (ADS)

    Koenrades, Maaike A.; Struijs, Ella M.; Klein, Almar; Kuipers, Henny; Geelkerken, Robert H.; Slump, Cornelis H.

    2017-03-01

    The application of endovascular aortic aneurysm repair has expanded over the last decade. However, the long-term performance of stent grafts, in particular durable fixation and sealing to the aortic wall, remains the main concern of this treatment. The sealing and fixation are challenged at every heartbeat due to downward and radial pulsatile forces. Yet knowledge on cardiac-induced dynamics of implanted stent grafts is sparse, as it is not measured in routine clinical follow-up. Such knowledge is particularly relevant to perform fatigue tests, to predict failure in the individual patient and to improve stent graft designs. Using a physical dynamic stent graft model in an anthropomorphic phantom, we have evaluated the performance of our previously proposed segmentation and registration algorithm to detect periodic motion of stent grafts on ECG-gated (3D+t) CT data. Abdominal aortic motion profiles were simulated in two series of Gaussian based patterns with different amplitudes and frequencies. Experiments were performed on a 64-slice CT scanner with a helical scan protocol and retrospective gating. Motion patterns as estimated by our algorithm were compared to motion patterns obtained from optical camera recordings of the physical stent graft model in motion. Absolute errors of the patterns' amplitude were smaller than 0.28 mm. Even the motion pattern with an amplitude of 0.23 mm was measured, although the amplitude of motion was overestimated by the algorithm with 43%. We conclude that the algorithm performs well for measurement of stent graft motion in the mm and sub-mm range. This ultimately is expected to aid in patient-specific risk assessment and improving stent graft designs.

  16. Patient-tailored Drug-eluting Stent Choice - A Solution for Patients with Diabetes: Proceedings of Two Satellite Symposia Held at EuroPCR in May 2015 in Paris.

    PubMed

    Mountfort, Katrina; Mehran, Roxana; Colombo, Antonio; Stella, Pieter; Romaguera, Rafael; Sardella, Gennaro

    2015-09-01

    Although second-generation drug-eluting stents (DES) have improved outcomes in percutaneous coronary interventions (PCIs), important unmet needs remain. Two symposia at EuroPCR 2015 focused on two challenging scenarios. First, patients with diabetes mellitus (DM) have generally inferior outcomes following PCI. The Cre8™ stent (manufactured by CID Spa, member of Alvimedica Group) has shown unique efficacy in subpopulations of patients with DM during clinical trials. A live case in a patient with diabetes illustrated the challenges of complex multivessel disease. Second, optimising stent selection towards devices that have demonstrated complete and early endothelialisation offers the potential to reduce the duration of dual antiplatelet therapy. The Cre8™ DES features a polymer-free platform and has been associated with low rates of in-stent thrombosis.

  17. Carotid artery stenting vs. carotid endarterectomy in the management of carotid artery stenosis: Lessons learned from randomized controlled trials

    PubMed Central

    Salem, Mohamed M.; Alturki, Abdulrahman Y.; Fusco, Matthew R.; Thomas, Ajith J.; Carter, Bob S.; Chen, Clark C.; Kasper, Ekkehard M.

    2018-01-01

    Background: Carotid artery stenosis, both symptomatic and asymptomatic, has been well studied with several multicenter randomized trials. The superiority of carotid endarterectomy (CEA) to medical therapy alone in both symptomatic and asymptomatic carotid artery stenosis has been well established in previous trials in the 1990s. The consequent era of endovascular carotid artery stenting (CAS) has offered another option for treating carotid artery stenosis. A series of randomized trials have now been conducted to compare CEA and CAS in the treatment of carotid artery disease. The large number of similar trials has created some confusion due to inconsistent results. Here, the authors review the trials that compare CEA and CAS in the management of carotid artery stenosis. Methods: The PubMed database was searched systematically for randomized controlled trials published in English that compared CEA and CAS. Only human studies on adult patients were assessed. The references of identified articles were reviewed for additional manuscripts to be included if inclusion criteria were met. The following terms were used during search: carotid stenosis, endarterectomy, stenting. Retrospective or single-center studies were excluded from the review. Results: Thirteen reports of seven large-scale prospective multicenter studies, comparing both interventions for symptomatic or asymptomatic extracranial carotid artery stenosis, were identified. Conclusions: While the superiority of intervention to medical management for symptomatic patients has been well established in the literatures, careful selection of asymptomatic patients for intervention should be undertaken and only be pursued after institution of appropriate medical therapy until further reports on trials comparing medical therapy to intervention in this patient group are available. PMID:29740506

  18. Carotid artery stenting: current and emerging options

    PubMed Central

    Morr, Simon; Lin, Ning; Siddiqui, Adnan H

    2014-01-01

    Carotid artery stenting technologies are rapidly evolving. Options for endovascular surgeons and interventionists who treat occlusive carotid disease continue to expand. We here present an update and overview of carotid stenting devices. Evidence supporting carotid stenting includes randomized controlled trials that compare endovascular stenting to open surgical endarterectomy. Carotid technologies addressed include the carotid stents themselves as well as adjunct neuroprotective devices. Aspects of stent technology include bare-metal versus covered stents, stent tapering, and free-cell area. Drug-eluting and cutting balloon indications are described. Embolization protection options and new direct carotid access strategies are reviewed. Adjunct technologies, such as intravascular ultrasound imaging and risk stratification algorithms, are discussed. Bare-metal and covered stents provide unique advantages and disadvantages. Stent tapering may allow for a more fitted contour to the caliber decrement between the common carotid and internal carotid arteries but also introduces new technical challenges. Studies regarding free-cell area are conflicting with respect to benefits and associated risk; clinical relevance of associated adverse effects associated with either type is unclear. Embolization protection strategies include distal filter protection and flow reversal. Though flow reversal was initially met with some skepticism, it has gained wider acceptance and may provide the advantage of not crossing the carotid lesion before protection is established. New direct carotid access techniques address difficult anatomy and incorporate sophisticated flow-reversal embolization protection techniques. Carotid stenting is a new and exciting field with rapidly advancing technologies. Embolization protection, low-risk deployment, and lesion assessment and stratification are active areas of research. Ample room remains for further innovations and developments. PMID:25349483

  19. Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial

    PubMed Central

    McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.

    2014-01-01

    Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID:20644013

  20. Long term outcomes of new generation drug eluting stents versus coronary artery bypass grafting for multivessel and/or left main coronary artery disease. A Bayesian network meta-analysis of randomized controlled trials.

    PubMed

    Mina, George S; Watti, Hussam; Soliman, Demiana; Shewale, Anand; Atkins, Jessica; Reddy, Pratap; Dominic, Paari

    2018-01-05

    Most data guiding revascularization of multivessel disease (MVD) and/or left main disease (LMD) favor coronary artery bypass grafting (CABG) over percutaneous coronary intervention (PCI). However, those data are based on trials comparing CABG to bare metal stents (BMS) or old generation drug eluting stents (OG-DES). Hence, it is essential to outcomes of CABG to those of new generation drug eluting stents (NG-DES). We searched PUBMED and Cochrane database for trials evaluating revascularization of MVD and/or LMD with CABG and/or PCI. A Bayesian network meta-analysis was performed to calculate odds ratios (OR) and 95% credible intervals (CrI). Primary outcome was major adverse cardiovascular events (MACE) at 3-5 years. Secondary outcomes were mortality, cerebrovascular accidents (CVA), myocardial infarction (MI) and repeat revascularization. We included 10 trials with a total of 9287 patients. CABG was associated with lower MACE when compared to BMS or OG-DES. However, MACE was not significantly different between CABG and NG-DES (OR 0.79, CrI 0.45-1.40). Moreover, there were no significant differences between CABG and NG-DES in mortality (OR 0.78, CrI 0.45-1.37), CVA (OR 0.93 CrI 0.35-2.2) or MI (OR 0.6, CrI 0.17-2.0). On the other hand, CABG was associated with lower repeat revascularization (OR 0.55, CrI 0.36-0.84). Our study suggests that NG-DES is an acceptable alternative to CABG in patients with MVD and/or LMD. However, repeat revascularization remains to be lower with CABG than with PCI. Copyright © 2018. Published by Elsevier Inc.

  1. Carotid artery stenting in high surgical risk patients using the FiberNet embolic protection system: the EPIC trial results.

    PubMed

    Myla, Subbarao; Bacharach, J Michael; Ansel, Gary M; Dippel, Eric J; McCormick, Daniel J; Popma, Jeffrey J

    2010-05-01

    The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single-arm trial evaluated the 30-day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Embolic protection filters available for use during CAS include fixed and over-the-wire systems that rely on embolic material capture within a "basket" structure. The FiberNet Embolic Protection System (EPS), which features a very low crossing profile, consists of a three-dimensional fiber-based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30-day follow-up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30-day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30-day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). Copyright 2010 Wiley-Liss, Inc.

  2. Perspectives on the management of antiplatelet therapy in patients with coronary artery disease requiring cardiac and noncardiac surgery.

    PubMed

    Franchi, Francesco; Rollini, Fabiana; Angiolillo, Dominick J

    2014-11-01

    To provide an updated overview on the management of antiplatelet therapy in patients with coronary stents undergoing cardiac and noncardiac surgery. Surgical procedures are frequently performed in patients with coronary stents and are associated with an increased risk of ischemic and bleeding complications in the perioperative period. Given the lack of well-designed prospective randomized trials, guidelines recommendations are currently derived from observational studies and expert consensus. Defining the optimal balance between the risk of thrombotic events following discontinuation of antiplatelet therapy and the risk of hemorrhagic complications of having a surgical procedure while on antiplatelet therapy is pivotal. Elective surgery should be postponed for at least 4 weeks after bare metal stent implantation and 6-12 months after drug-eluting stent. If this is not possible, aspirin should be continued in the perioperative period, although the management of P2Y₁₂ inhibitors should be individualized according to the individual patient and type of surgery. In the absence of well-defined recommendations deriving from prospective randomized clinical trials, the perioperative management of antiplatelet therapy should be based on the balance between the specific thrombotic and hemorrhagic risks that characterize each patient and each surgical procedure.

  3. Comparison of the SYNERGY with the PROMUS (XIENCE V) and bare metal and polymer-only Element control stents in porcine coronary arteries.

    PubMed

    Wilson, Gregory J; Huibregtse, Barbara A; Pennington, Douglas E; Dawkins, Keith D

    2012-06-20

    This study evaluated vascular compatibility of the novel platinum chromium alloy Element stent platform delivering abluminal everolimus from a poly-lactide-co-glycolide bioabsorbable polymer (SYNERGY stent), currently undergoing clinical trial, compared with the PROMUS (XIENCE V) and bare metal and polymer-only Element stents. Stents (n=161) were implanted one per coronary artery in 72 swine at a stent-to-artery ratio of 1.1:1. Similar numbers of each device group were explanted at each of 30, 90, 180, and 360 days (except no PROMUS (XIENCE V) stent at 360 days) for pathological analysis. There was no stent thrombosis, myocardial infarction, or strut fractures in any group. Vascular response was similar between the SYNERGY and PROMUS (XIENCE V) stents, with no thrombi and complete endothelialisation on both scanning electron microscopy and histology at 30, 90 and 180 days. There were no significant differences for the morphologic parameters of luminal thrombus, endothelial cell coverage, strut tissue coverage, inflammation, internal elastic lamina (IEL) disruption, external elastic lamina (EEL) disruption and medial smooth muscle cell loss across device groups or between time points, but there was mild but greater (p<0.0001) para-strut fibrin at 30 days for both drug-eluting stents (DES) compared with the bare and polymer-only controls; this difference completely dissipated by 90 days. Inflammation was predominantly minimal to mild for all device types. No morphometric parameters, including intimal thickness, stent profile-based area stenosis, and EEL area were significantly different when comparing the SYNERGY stent with the bare metal Element and polymer-only Element control stents at 90, 180 and 360 days. In this non-injured porcine coronary artery model, the bioabsorbable polymer SYNERGY stent demonstrated vascular compatibility equivalent to the PROMUS (XIENCE V) stent and to the bare metal and polymer-only Element stents.

  4. Feasibility and safety of placement of a newly designed, fully covered self-expandable metal stent for refractory benign pancreatic ductal strictures: a pilot study (with video).

    PubMed

    Park, Do Hyun; Kim, Myung-Hwan; Moon, Sung-Hoon; Lee, Sang Soo; Seo, Dong-Wan; Lee, Sung-Koo

    2008-12-01

    Painful chronic pancreatitis with main pancreatic ductal strictures is usually managed with endotherapy with a plastic stent. To date, the role of placement of metallic stents, especially uncovered ones in benign pancreatic ductal stricture, has been unsatisfactory as a result of stent dysfunction related to mucosal hyperplasia. We explored the feasibility and safety of temporary placement of a newly designed, fully covered self-expandable metal stent (FCSEMS) in painful chronic pancreatitis and refractory benign pancreatic ductal strictures. A prospective pilot and feasibility study. A tertiary academic center. Thirteen patients with chronic painful pancreatitis of alcoholic (8) or idiopathic (5) etiology. ERCP with temporary FCSEMS placement (2 months). Endoscopic removal of FCSEMSs was performed with a snare or rat-tooth forceps. End points were feasibility, safety, and morbidity. Successful FCSEMS placement was performed in all enrolled patients. After immediate placement of FCSEMS, 2 patients had mild acute pancreatitis related mainly to the stricture dilation procedure (Soehendra stent retriever or balloon dilation). Complications associated with stent placement included 5 migrations (39%, 1 proximal and 4 distal) and 2 incidents of cholestatic liver dysfunction associated with the compression of the bile duct orifice by expansion of FCSEMSs. In 1 patient with proximal migration, the stent was repositioned by an inflated retrieval balloon. Additional endoscopic biliary sphincterotomy with or without biliary stenting was performed in 2 patients with cholestatic liver dysfunction. There was no occurrence of pancreatic sepsis among any patients. FCSEMSs were removed from 9 of 9 patients without stent migration (100% [9/9] as per protocol, and 69% [9/13] as intention to treat, respectively). Improvement or resolution of the pancreatic ductal strictures was confirmed in all 13 patients on follow-up ERCP (2 months after stent placement), regardless of stent migration. Small patient populations without long-term follow-up. Two-month placement of FCSEMSs in patients with refractory benign pancreatic ductal strictures may be feasible and relatively safe. However, stent migration was not uncommon. A further investigation with ideal stent design may therefore be needed before recommending FCSEMSs as a therapeutic option for refractory benign pancreatic ductal strictures.

  5. A systematic review and meta-analysis of randomized trials and prospective studies comparing covered and bare self-expandable metal stents for the treatment of malignant obstruction in the digestive tract.

    PubMed

    Yang, Zhiping; Wu, Qiong; Wang, Fang; Ye, Xiaofei; Qi, Xingshun; Fan, Daiming

    2013-01-01

    Self-expandable metal stents (SEMS) are widely used for the palliative treatment of malignant gastrointestinal obstruction. Our aim was to evaluate the evidence comparing covered and bare SEMS in the digestive tract using meta-analytical techniques. A literature search was performed using PubMed, Cochrane Library, and Embase databases for comparative studies assessing the two types of stents. The primary outcomes of interest were stent patency and patient survival; second outcomes included technical success, clinical success, tumor ingrowth, tumor overgrowth, and stent migration. A random-effects model was conducted. Pooled analysis was done separately based on the different segments of the digestive tract. Eleven studies (8 randomized controlled trials and 3 prospective cohort studies) including a total of 1376 patients were identified. Covered SEMS were equivalent to bare SEMS in terms of technical success, clinical success, stent patency (gastroduodenal obstruction: HR =0.87, 95% CI 0.53-1.42; colorectal obstruction: HR =0.89, 95% CI 0.18-4.45; biliary obstruction: HR =0.73, 95% CI 0.41-1.32) and survival rates (esophageal obstruction: HR =1.80, 95% CI 0.73-4.44; gastroduodenal obstruction: HR =0.83, 95% CI 0.55-1.26; biliary obstruction: HR =0.99, 95% CI 0.77-1.28), although bare stents were more prone to tumor ingrowth (esophageal obstruction: RR =0.10, 95% CI 0.01-0.77; gastroduodenal obstruction: RR =0.12, 95% CI 0.03-0.55; colorectal obstruction: RR =0.21, 95% CI 0.06-0.70; biliary obstruction: RR =0.21, 95% CI 0.06-0.69), whereas covered stents had the higher risk of stent migration (gastroduodenal obstruction: RR =5.01, 95% CI 1.53-16.43; colorectal obstruction: RR =11.70, 95% CI 2.84-48.27; biliary obstruction: RR =8.11, 95% CI 1.47-44.76) and tumor overgrowth (biliary obstruction: RR =2.03, 95% CI 1.08-3.78). Both covered and bare SEMS are comparable in efficacy for the palliative treatment of malignant obstruction in the digestive tract. Each type of the stents has its own merit and demerit relatively.

  6. Efficacy of a Multiplex Paclitaxel Emission Stent Using a Pluronic® Mixture Membrane versus a Covered Metal Stent in Malignant Biliary Obstruction: A Prospective Randomized Comparative Study.

    PubMed

    Jang, Sung Ill; Lee, Se Joon; Jeong, Seok; Lee, Don Haeng; Kim, Myung-Hwan; Yoon, Hong Jin; Lee, Dong Ki

    2017-07-15

    A drug-eluting stent for unresectable malignant biliary obstruction was developed to increase stent patency by preventing tumor ingrowth. The safety and efficacy of a new generation of metallic stents covered with a paclitaxel-incorporated membrane using a Pluronic ® mixture (MSCPM-II) were compared prospectively with those of covered metal stents (CMSs) in patients with malignant biliary obstructions. This study was initially designed as a prospective randomized trial but was closed early because of a high incidence of early occlusion. Therefore, the data were analyzed using the intent-to-treat method. A total of 72 patients with unresectable distal malignant biliary obstructions were prospectively enrolled. The two groups did not differ significantly in basic characteristics and mean follow-up period (MSCPM-II 194 days vs CMS 277 days, p=0.063). Stent occlusion occurred in 14 patients (35%) who received MSCPM-II and in seven patients (21.9%) who received CMSs. Stent patency and survival time did not significantly differ between the two groups (p=0.355 and p=0.570). The complications were mild and resolved by conservative management in both groups. There were no significant differences in stent patency or patient survival in MSCPM-II and CMS patients with malignant biliary obstructions.

  7. Predictors of acute and persisting ischemic brain lesions in patients randomized to carotid stenting or endarterectomy.

    PubMed

    Rostamzadeh, Ayda; Zumbrunn, Thomas; Jongen, Lisa M; Nederkoorn, Paul J; Macdonald, Sumaira; Lyrer, Philippe A; Kappelle, L Jaap; Mali, Willem P Th M; Brown, Martin M; van der Worp, H Bart; Engelter, Stefan T; Bonati, Leo H

    2014-02-01

    We investigated predictors for acute and persisting periprocedural ischemic brain lesions among patients with symptomatic carotid stenosis randomized to stenting or endarterectomy in the International Carotid Stenting Study. We assessed acute lesions on diffusion-weighted imaging 1 to 3 days after treatment in 124 stenting and 107 endarterectomy patients and lesions persisting on fluid-attenuated inversion recovery after 1 month in 86 and 75 patients, respectively. Stenting patients had more acute (relative risk, 8.8; 95% confidence interval, 4.4-17.5; P<0.001) and persisting lesions (relative risk, 4.2; 95% confidence interval, 1.6-11.1; P=0.005) than endarterectomy patients. Acute lesion count was associated with age (by trend), male sex, and stroke as the qualifying event in stenting; high systolic blood pressure in endarterectomy; and white matter disease in both groups. The rate of conversion from acute to persisting lesions was lower in the stenting group (relative risk, 0.4; 95% confidence interval, 0.2-0.8; P=0.007), and was only predicted by acute lesion volume. Stenting caused more acute and persisting ischemic brain lesions than endarterectomy. However, the rate of conversion from acute to persisting lesions was lower in the stenting group, most likely attributable to lower acute lesion volumes. Clinical Trial Registration -URL: www.isrctn.org. Unique identifier: ISRCTN25337470.

  8. Targeted stent use in clinical practice based on evidence from the Basel Stent Cost Effectiveness Trial (BASKET).

    PubMed

    Brunner-La Rocca, Hans-Peter; Kaiser, Christoph; Pfisterer, Matthias

    2007-03-01

    It is unknown which patients benefit most from drug-eluting stents (DES) against bare-metal stents (BMS) in a long-term clinical outcome. To address this question, data from 826 consecutive patients with angioplasty, randomized 2:1 to DES vs. BMS, with an 18-month follow-up for cardiac death/myocardial infarction (MI) and non-MI-related target-vessel revascularization (TVR) were analysed for interactions between stent type and patient/vessel characteristics predicting events. Rates of 18-month TVRs were lower with DES vs. BMS use (7.5 vs. 11.6%, P = 0.05), but similar for both stents regarding cardiac death/MI (DES, 8.4%; BMS, 7.5%; P = 0.70). Significant interactions between stent type and two multivariable event predictors were identified: small stents (<3.0 mm) and bypass graft stenting. In these patient groups together (n = 268, 32%), DES reduced non-MI-related TVR (HR = 0.44; P = 0.02) and cardiac death/MI (HR = 0.44; P = 0.04), whereas in the other 558 patients (68%) TVR rate was similar (HR = 0.75; P = 0.38) and cardiac death/MI rate increased after DES (HR = 2.07; P = 0.05). Patients with angioplasty of small vessels or bypass grafts seem to benefit from DES use, in long-term outcome, in contrast to patients with large native vessel stenting where there might even be late harm. Still, this hypothesis needs to be tested prospectively.

  9. Quantitative multi-modality imaging analysis of a bioabsorbable poly-L-lactic acid stent design in the acute phase: a comparison between 2- and 3D-QCA, QCU and QMSCT-CA.

    PubMed

    Bruining, Nico; Tanimoto, Shuzou; Otsuka, Masato; Weustink, Annick; Ligthart, Jurgen; de Winter, Sebastiaan; van Mieghem, Carlos; Nieman, Koen; de Feyter, Pim J; van Domburg, Ron T; Serruys, Patrick W

    2008-08-01

    To investigate if three-dimensional (3D) based quantitative techniques are comparable to each other and to explore possible differences with respect to the reference method of 2D-QCA in the acute phase and to study whether non-invasive MSCT could potentially be applied to quantify luminal dimensions of a stented coronary segment with a novel bioabsorable drug-eluting stent made of poly-l-lactic-acid (PLLA). Quantitative imaging data derived from 16 patients enrolled at our institution in a first-in-man trial (ABSORB) receiving a biodegradable stent and who were imaged with standard coronary angiography and intravascular ultrasound were compared. Shortly, after stenting the patients also underwent a MSCT procedure. Standard 2D-QCA showed significant smaller stent lengths (p < 0.01). Although, the absolute measured stent diameters and areas by 2D-QCA tend to be smaller, the differences failed to be statistically different when compared to the 3D based quantitative modalities. Measurements made by non-invasive QMSCT-CA of implanted PLLA stents appeared to be comparable to the other 3D modalities without significant differences. Three-dimensional based quantitative analyses showed similar results quantifying luminal dimensions as compared to 2D-QCA during an evaluation of a new bioabsorbable coronary stent design in the acute phase. Furthermore, in biodegradable stents made of PLLA, non-invasive QMSCT-CA can be used to quantify luminal dimensions.

  10. Role of Animal Models in Coronary Stenting.

    PubMed

    Iqbal, Javaid; Chamberlain, Janet; Francis, Sheila E; Gunn, Julian

    2016-02-01

    Coronary angioplasty initially employed balloon dilatation only. This technique revolutionized the treatment of coronary artery disease, although outcomes were compromised by acute vessel closure, late constrictive remodeling, and restenosis due to neointimal proliferation. These processes were studied in animal models, which contributed to understanding the biology of endovascular arterial injury. Coronary stents overcome acute recoil, with improvements in the design and metallurgy since then, leading to the development of drug-eluting stents and bioresorbable scaffolds. These devices now undergo computer modeling and benchtop and animal testing before evaluation in clinical trials. Animal models, including rabbit, sheep, dog and pig are available, all with individual benefits and limitations. In smaller mammals, such as mouse and rabbit, the target for stenting is generally the aorta; whereas in larger animals, such as the pig, it is generally the coronary artery. The pig coronary stenting model is a gold-standard for evaluating safety; but insights into biomechanical properties, the biology of stenting, and efficacy in controlling neointimal proliferation can also be gained. Intra-coronary imaging modalities such as intravascular ultrasound and optical coherence tomography allow precise serial evaluation in vivo, and recent developments in genetically modified animal models of atherosclerosis provide realistic test beds for future stents and scaffolds.

  11. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    PubMed Central

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and fistulae is promising. PMID:25685270

  12. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    PubMed

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and fistulae is promising.

  13. Percutaneous intraductal radiofrequency ablation for treatment of biliary stent occlusion: A preliminary result.

    PubMed

    Xia, Ning; Gong, Ju; Lu, Jian; Chen, Zhi-Jin; Zhang, Li-Yun; Wang, Zhong-Min

    2017-03-14

    To assess the feasibility and effectiveness of a novel application of percutaneous intraductal radiofrequency (RF) for the treatment of biliary stent obstruction. We specifically report a retrospective study presenting the results of percutaneous intraductal RF in patients with biliary stent occlusion. A total of 43 cases involving biliary stent obstruction were treated by placing an EndoHPB catheter and percutaneous intraductal RF was performed to clean stents. The stent patency was evaluated by cholangiography and follow-up by contrast enhanced computed tomography or ultrasound after the removal of the drainage catheter. Following the procedures, of the 43 patients, 40 survived and 3 died with a median survival of 80.5 (range: 30-243) d. One patient was lost to follow-up. One patient had the stent patent at the time of last follow-up. Two patients with stent blockage at 35 d and 44 d after procedure underwent percutaneous transhepatic drain insertion only. The levels of bilirubin before and after the procedure were 128 ± 65 μmol/L and 63 ± 29 μmol/L, respectively. There were no related complications (haemorrhage, bile duct perforation, bile leak or pancreatitis) and all patients' stent patency was confirmed by cholangiography after the procedure, with a median patency time of 107 (range: 12-180) d. This preliminary clinical study demonstrated that percutaneous intraductal RF is safe and effective for the treatment of biliary stent obstruction, increasing the duration of stent patency, although randomized controlled trials are needed to confirm the effectiveness of this approach.

  14. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    PubMed

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  15. Percutaneous intraductal radiofrequency ablation for treatment of biliary stent occlusion: A preliminary result

    PubMed Central

    Xia, Ning; Gong, Ju; Lu, Jian; Chen, Zhi-Jin; Zhang, Li-Yun; Wang, Zhong-Min

    2017-01-01

    AIM To assess the feasibility and effectiveness of a novel application of percutaneous intraductal radiofrequency (RF) for the treatment of biliary stent obstruction. METHODS We specifically report a retrospective study presenting the results of percutaneous intraductal RF in patients with biliary stent occlusion. A total of 43 cases involving biliary stent obstruction were treated by placing an EndoHPB catheter and percutaneous intraductal RF was performed to clean stents. The stent patency was evaluated by cholangiography and follow-up by contrast enhanced computed tomography or ultrasound after the removal of the drainage catheter. RESULTS Following the procedures, of the 43 patients, 40 survived and 3 died with a median survival of 80.5 (range: 30-243) d. One patient was lost to follow-up. One patient had the stent patent at the time of last follow-up. Two patients with stent blockage at 35 d and 44 d after procedure underwent percutaneous transhepatic drain insertion only. The levels of bilirubin before and after the procedure were 128 ± 65 μmol/L and 63 ± 29 μmol/L, respectively. There were no related complications (haemorrhage, bile duct perforation, bile leak or pancreatitis) and all patients’ stent patency was confirmed by cholangiography after the procedure, with a median patency time of 107 (range: 12-180) d. CONCLUSION This preliminary clinical study demonstrated that percutaneous intraductal RF is safe and effective for the treatment of biliary stent obstruction, increasing the duration of stent patency, although randomized controlled trials are needed to confirm the effectiveness of this approach. PMID:28348491

  16. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.

    PubMed

    Sabaté, Manel; Räber, Lorenz; Heg, Dik; Brugaletta, Salvatore; Kelbaek, Henning; Cequier, Angel; Ostojic, Miodrag; Iñiguez, Andrés; Tüller, David; Serra, Antonio; Baumbach, Andreas; von Birgelen, Clemens; Hernandez-Antolin, Rosana; Roffi, Marco; Mainar, Vicente; Valgimigli, Marco; Serruys, Patrick W; Jüni, Peter; Windecker, Stephan

    2014-01-01

    This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis

    PubMed Central

    Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    Aim To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. Methods We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. Results The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19–4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05–10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57–1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94–1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56–0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12–0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03–3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54–34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36–4.50; p = 0.003, I2 = 0%). Conclusions Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary obstruction due to their removability. PMID:26859673

  18. Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type.

    PubMed

    Camenzind, Edoardo; Boersma, Eric; Wijns, William; Mauri, Laura; Rademaker-Havinga, Tessa; Ordoubadi, Farzin Fath; Suttorp, Maarten J; Al Kurdi, Mohammad; Steg, Ph Gabriel

    2014-08-01

    To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  19. To kiss or not to kiss? Impact of final kissing-balloon inflation on early and long-term results of percutaneous coronary intervention for bifurcation lesions.

    PubMed

    Biondi-Zoccai, Giuseppe; Sheiban, Imad; De Servi, Stefano; Tamburino, Corrado; Sangiorgi, Giuseppe; Romagnoli, Enrico

    2014-11-01

    Final kissing-balloon inflation is often recommended for percutaneous coronary intervention (PCI) of bifurcation lesions. However, randomized trials focusing on kissing inflation have not confirmed its beneficial impact. We compared outcomes of kissing inflation for PCI of bifurcation lesions, explicitly stratifying results according to stenting strategy. Patients undergoing bifurcation PCI were retrospectively enrolled. Subjects receiving final kissing inflation were compared with those not undergoing kissing inflation, after stratification for a single-stent technique. The primary end point was the long-term rate of major adverse cardiac events (MACE, i.e., death, myocardial infarction, or target lesion revascularization (TLR)). A total of 4314 patients were included: 1176 (27.3 %) treated with a single stent and kissing inflation, 1637 (37.9 %) with a single stent but no kissing, 1072 (24.8 %) with two stents and kissing, and 429 (9.9 %) with two stents but no kissing. At unadjusted analyses kissing was associated with fewer short-term MACE and deaths in the two-stent group, and with fewer long-term MACE, cardiac deaths, and side-branch TLR in the two-stent group (all P < 0.05). Conversely, kissing appeared detrimental after single stenting. However, after multivariable analyses, kissing no longer significantly affected the risk of adverse events, with the exception of the risk of side-branch TLR, which was lower in those receiving two stents and final kissing inflation (hazard ratio = 0.52, 95 % confidence interval 0.30–0.90, P = 0.020). Kissing inflation can be avoided in bifurcation lesions uneventfully treated with single-stent PCI. However, final kissing-balloon inflation appears beneficial in reducing the risk of side-branch repeat revascularization after using a two-stent strategy.

  20. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    PubMed

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Randomized comparison of percutaneous coronary intervention with coronary artery bypass grafting in diabetic patients. 1-year results of the CARDia (Coronary Artery Revascularization in Diabetes) trial.

    PubMed

    Kapur, Akhil; Hall, Roger J; Malik, Iqbal S; Qureshi, Ayesha C; Butts, Jeremy; de Belder, Mark; Baumbach, Andreas; Angelini, Gianni; de Belder, Adam; Oldroyd, Keith G; Flather, Marcus; Roughton, Michael; Nihoyannopoulos, Petros; Bagger, Jens Peder; Morgan, Kenneth; Beatt, Kevin J

    2010-02-02

    The purpose of this study was to compare the safety and efficacy of percutaneous coronary intervention (PCI) with stenting against coronary artery bypass grafting (CABG) in patients with diabetes and symptomatic multivessel coronary artery disease. CABG is the established method of revascularization in patients with diabetes and multivessel coronary disease, but with advances in PCI, there is uncertainty whether CABG remains the preferred method of revascularization. The primary outcome was a composite of all-cause mortality, myocardial infarction (MI), and stroke, and the main secondary outcome included the addition of repeat revascularization to the primary outcome events. A total of 510 diabetic patients with multivessel or complex single-vessel coronary disease from 24 centers were randomized to PCI plus stenting (and routine abciximab) or CABG. The primary comparison used a noninferiority method with the upper boundary of the 95% confidence interval (CI) not to exceed 1.3 to declare PCI noninferior. Bare-metal stents were used initially, but a switch to Cypher (sirolimus drug-eluting) stents (Cordis, Johnson & Johnson, Bridgewater, New Jersey) was made when these became available. At 1 year of follow-up, the composite rate of death, MI, and stroke was 10.5% in the CABG group and 13.0% in the PCI group (hazard ratio [HR]: 1.25, 95% CI: 0.75 to 2.09; p=0.39), all-cause mortality rates were 3.2% and 3.2%, and the rates of death, MI, stroke, or repeat revascularization were 11.3% and 19.3% (HR: 1.77, 95% CI: 1.11 to 2.82; p=0.02), respectively. When the patients who underwent CABG were compared with the subset of patients who received drug-eluting stents (69% of patients), the primary outcome rates were 12.4% and 11.6% (HR: 0.93, 95% CI: 0.51 to 1.71; p=0.82), respectively. The CARDia (Coronary Artery Revascularization in Diabetes) trial is the first randomized trial of coronary revascularization in diabetic patients, but the 1-year results did not show that PCI is noninferior to CABG. However, the CARDia trial did show that multivessel PCI is feasible in patients with diabetes, but longer-term follow-up and data from other trials will be needed to provide a more precise comparison of the efficacy of these 2 revascularization strategies. (The Coronary Artery Revascularisation in Diabetes trial; ISRCTN19872154). Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Antithrombotic therapy in anticoagulated patients with atrial fibrillation presenting with acute coronary syndromes and/or undergoing percutaneous coronary intervention/stenting.

    PubMed

    Wrigley, Benjamin J; Tapp, Luke D; Shantsila, Eduard; Lip, Gregory Yh

    2010-07-01

    The management of antithrombotic therapy in atrial fibrillation patients presenting with acute coronary syndrome and/or undergoing percutaneous coronary inter vention/stenting cannot be done according to a regimented common protocol, and stroke and bleeding risk stratification schema should be employed to individualize treatment options. A delicate balance is needed between the prevention of thromboembolism, against recurrent cardiac ischemia or stent thrombosis, and bleeding risk. New guidance from a consensus document of the European Society of Cardiology Working Group on Thrombosis, endorsed by the European Heart Rhythm Association and the European Association of Percutaneous Cardiovascular Interventions on the management of Antithrombotic Therapy in Atrial Fibrillation Patients Presenting with Acute Coronary Syndrome and/or Undergoing Percutaneous Coronary Intervention/Stenting has sought to clarify some of the major issues and problems surrounding this practice, and will allow clinicians to make much more informed decisions when faced with treating such patients.

  3. Prospective trial of biodegradable stents for refractory benign esophageal strictures after curative treatment of esophageal cancer.

    PubMed

    Yano, Tomonori; Yoda, Yusuke; Nomura, Shogo; Toyosaki, Kayo; Hasegawa, Hiromi; Ono, Hiroyuki; Tanaka, Masaki; Morimoto, Hiroyuki; Horimatsu, Takahiro; Nonaka, Satoru; Kaneko, Kazuhiro; Sato, Akihiro

    2017-09-01

    Biodegradable stents are reportedly effective for refractory benign esophageal strictures; however, little is known about their use in patients with refractory stricture after endoscopic submucosal dissection (ESD) or chemoradiotherapy (CRT) for esophageal cancer. This study aimed to evaluate the effectiveness of biodegradable stents for these patients. Patients with refractory benign esophageal stricture with a dysphagia score (DS) of 2 or worse and for whom the passage of a standard size endoscope was not possible were eligible. The primary endpoint was the proportion of those who improved their DSs (% DS improved) at 12 weeks after stent placement, and the secondary endpoints were the proportion of those who improved their DSs at 24 weeks, dysphagia-free survival (DFS), and adverse events. Eighteen patients (men:women, 15:3; median age, 72 years; range, 53-80) were enrolled. Twelve patients improved their DS at 12 weeks (% DS improved, 66.7%; 90% CI, 44.6%-84.4%). Also, 8 of 11 patients (72.7%) after esophagectomy, 4 of 6 patients (66.7%) after ESD, and 3 of 4 patients (75%) after CRT improved at 12 weeks. Three patients who were treated with esophagectomy maintained their DS improvement at 24 weeks (% DS improved, 16.7%; 95% CI, 3.6%-41.4%). The median DFS was 14.1 weeks (95% CI, 13.0-19.0). One patient who had ESD and CRT developed an esophagobronchial fistula 3 months after stent placement. Biodegradable stents are effective and tolerable for refractory benign esophageal strictures after treatment for esophageal cancer; however, long-term efficacy was limited, especially after ESD or CRT. (Clinical trial registration number: UMIN000008054.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. [Acetylsalicylic acid desensitization in the new era of percutaneous coronary intervention].

    PubMed

    Fuertes Ferre, Georgina; Ferrer Gracia, Maria Cruz; Calvo Cebollero, Isabel

    2015-09-21

    Dual antiplatelet therapy is essential in patients undergoing percutaneous coronary intervention with stent implantation. Hypersensitivity to acetylsalicylic acid (ASA) limits treatment options. Desensitization to ASA has classically been studied in patients with respiratory tract disease. Over the last years, many protocols have been described about ASA desensitization in patients with ischemic heart disease, including acute coronary syndrome and the need for coronary stent implantation. It is important to know the efficacy and safety of ASA desensitization in these patients. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  5. Effect of terazosin on lower urinary tract symptoms and pain due to double-J stent: a double-blind placebo-controlled randomized clinical trial.

    PubMed

    Mokhtari, Gholamreza; Shakiba, Maryam; Ghodsi, Sara; Farzan, Alireza; Heidari Nejad, Sayeh; Esmaeili, Samaneh

    2011-01-01

    We evaluated the effect of terazosin in the improvement of lower urinary tract symptoms and flank pain in patients with internal ureteral stents. In this double-blind randomized clinical trial, 73 patients with unilateral ureteral stone and hydroureteronephrosis who underwent insertion of an internal ureteral stent after transureteral lithotripsy (TUL) were randomized into two groups. 37 patients received terazosin 2 mg (once nightly) for 4 weeks and 36 patients received placebo for the same time duration. After 4 weeks, all patients were asked about the incidence of frequency, nocturia and urgency by an International Prostate Symptom Score (IPSS) questionnaire, flank pain and pain during urination by a visual analog scale (VAS) score, and hematuria. The mean VAS score was 2.21 in the terazosin group compared with 4.93 in the control group (p < 0.001). Nearly all the patients in the placebo group reported flank pain during urination but this was only reported in 54.5% of the patients in the terazosin group (p < 0.001). All criteria measured by the IPSS in the terazosin group were significantly lower than those in the placebo group (p = 0.0001). Administration of terazosin for patients with an internal ureteral stent relieved some stent-related symptoms such as flank pain, pain during voiding, frequency, nocturia and urgency, but had no effect on hematuria. Copyright © 2011 S. Karger AG, Basel.

  6. Polymer-Free Drug-Coated Coronary Stents Are Cost-Effective in Patients at High Bleeding Risk: Economic Evaluation of the LEADERS FREE Trial.

    PubMed

    Filipovic-Pierucci, Antoine; Durand-Zaleski, Isabelle; Butel, Thibault; Greene, Samantha; Hovasse, Thomas; Iñiguez, Andres; Nazzaro, Marco Stefano; Oldroyd, Keith G; Talwar, Suneel; Richardt, Gert; Windhovel, Ute; Urban, Philip; Morice, Marie-Claude

    2018-02-20

    In patients at high risk of bleeding who undergo PCI the biolimus A9 polymer-free drug coated stent (DCS) has superior efficacy and safety compared to a bare metal stent (BMS). We estimated the cost effectiveness of DCS vs. BMS. The Leaders FREE-based economic evaluation estimated service use and quality of life data collected prospectively. The entire trial population was analysed using cost-weights from England, France, Germany, Italy, Scotland and Spain. Country-specific QALYs were derived from EQ-5D scores. We estimated cost per event averted and per QALY gained. DCS use resulted in -0.095 cardiac deaths, target vessel MI, stent thrombosis and revascularization per patient (0.152 vs. 0.237;p<0.001). One-year QALYs were non-significantly higher in the DCS group. Total costs for the index admission were similar between groups. One-year costs using cost-weights from each of the 6 countries, including the additional €300 per DCS stent, ranged from €4,664-8,593 for DCS and €4,845-9,742 for BMS and were lower in the DCS group (England:€-428, France:€-137, Germany:€-33, Italy:€-522, Scotland:€-298, Spain:€-854). The probability that DCS dominated BMS was >50% in all countries. At a threshold of €10,000 per event averted DCS had a 98% probability of being cost-effective in all 6 countries.

  7. Rotational atherectomy before paclitaxel-eluting stent implantation in complex calcified coronary lesions: Two-year clinical outcome of the randomized ROTAXUS trial.

    PubMed

    de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-03-01

    In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.

  8. Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial

    PubMed Central

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-01-01

    OBJECTIVES: Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS: A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS: At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS: WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer. PMID:26372507

  9. True coronary bifurcation lesions: meta-analysis and review of literature.

    PubMed

    Athappan, Ganesh; Ponniah, Thirumalaikolundiusubramanian; Jeyaseelan, Lakshmanan

    2010-02-01

    Percutaneous intervention of true coronary bifurcation lesions is challenging. Based on the results of randomized trials and registry data, the approach of stenting of main vessel only with balloon dilatation of the side branch has become the default approach for false bifurcation lesions except when a complication occurs or in cases of suboptimal result. However, the optimal stenting strategy for true coronary bifurcation lesions - to stent or not to stent the side branch - is still a matter of debate. The purpose of this study was, therefore, to compare the clinical and angiographic outcomes of the double stent technique (stenting of the main branch and side branch) over the single stent technique (stenting of main vessel only with balloon dilatation of the side branch) for treatment of true coronary bifurcation lesions, with drug-eluting stents (DES). Comparative studies published between January 2000 and February 2009 of the double stent technique vs. single stent technique with DES for true coronary bifurcations were identified using an electronic search and reviewed using a random effects model. The primary endpoints of our study were side-branch and main-branch restenoses, all-cause mortality, myocardial infarction (MI) and target lesion revascularization (TLR) at longest available follow-up. The secondary endpoints of our analysis were postprocedural minimal luminal diameter (MLD) of the side branch and main branch, follow-up MLD of side branch and main branch and stent thrombosis. Heterogeneity was assessed and sensitivity analysis was performed to test the robustness of the overall summary odds ratios (ORs). Five studies comprising 1145 patients (616 single stent and 529 double stent) were included in the analysis. Three studies were randomized comparisons between the two techniques for true coronary bifurcation lesions. Incomplete reporting of data in the primary studies was common. The lengths of clinical and angiographic follow-up ranged between 6 and 12 months and 6 and 7 months, respectively. Postprocedural MLD of the side branch was significantly smaller in the single stent group [standardized mean difference (SMD) -0.71, 95% CI -0.88 to -0.54, P < 0.000, I2 = 0%]. The odds of side-branch restenosis (OR 1.11, 95% CI 0.47-2.67, P = 0.81, I2 = 76%), main-branch restenois (OR 0.88, 95% CI 0.56-1.39, P = 0.58, I = 0%), all-cause mortality (OR 0.52, 95% CI 0.11-2.45, P = 0.41, I2 = 0%), MI (OR 0.92, 95% CI 0.34-2.54, P = 0.87, I = 49%) and TLR (OR 0.87, 95% CI 0.46-1.65, P = 0.68, I2 = 0%) were similar between the two groups. Postprocedural MLD of the main branch [standardized mean difference (SMD) -0.08, 95% CI -0.42 to -0.26, P < 0.65, I2 = 67%], follow-up MLD of side branch (SMD -0.19, 95% CI -0.40 to 0.01, P < 0.31, I2 = 15%) and main branch MLD (SMD 0.17, 95% CI -0.18 to 0.542, P < 0.35, I2 = 65%) were also similar between the two groups. In patients undergoing percutaneous coronary intervention (PCI) for true coronary bifurcations, there is no added advantage of stenting both branches as compared with a conventional one-stent strategy. The results, however, need to be interpreted considering the poor study methods and/or poor quality of reporting in publications. We propose to move forward and consider the conduct of more systematic, well-designed and scientific trials to investigate the treatment of true coronary bifurcation lesions.

  10. Dedicated bifurcation stents

    PubMed Central

    Pillai, Ajith Ananthakrishna; Jayaraman, Balachander

    2012-01-01

    Bifurcation percutaneous coronary intervention (PCI) is still a difficult call for the interventionist despite advancements in the instrumentation, technical skill and the imaging modalities. With major cardiac events relate to the side-branch (SB) compromise, the concept and practice of dedicated bifurcation stents seems exciting. Several designs of such dedicated stents are currently undergoing trials. This novel concept and pristine technology offers new hope notwithstanding the fact that we need to go a long way in widespread acceptance and practice of these gadgets. Some of these designs even though looks enterprising, the mere complex delivering technique and the demanding knowledge of the exact coronary anatomy makes their routine use challenging. PMID:22572498

  11. Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.

    PubMed

    Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui

    2016-09-01

    Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept "bio-adaption" between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed.

  12. Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review

    PubMed Central

    Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui

    2016-01-01

    Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept “bio-adaption” between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed. PMID:27698548

  13. Airway stabilization with silicone stents for treating adult tracheobronchomalacia: a prospective observational study.

    PubMed

    Ernst, Armin; Majid, Adnan; Feller-Kopman, David; Guerrero, Jorge; Boiselle, Phillip; Loring, Stephen H; O'Donnell, Carl; Decamp, Malcolm; Herth, Felix J F; Gangadharan, Sidhu; Ashiku, Simon

    2007-08-01

    It is postulated that in patients with severe tracheobronchomalacia (TBM), airway stabilization with stents may relieve symptoms. To evaluate the effect of silicone stents (tracheal, mainstem bronchus, or both) on symptoms, quality of life, lung function, and exercise capacity in these patients. A prospective observational study in which baseline measurements were compared to those obtained 10 to 14 days after stent placement. Of 75 referred patients, 58 had severe disease and underwent therapeutic rigid bronchoscopy with stent placement. Mean age was 69 years (range, 39 to 91 years), 34 were men, 33 had COPD, and 13 had asthma. Almost all patients (n = 57) had dyspnea as a sole symptom or in combination with cough and recurrent infections; four patients required mechanical ventilation for respiratory failure. In 45 of 58 patients, there was reported symptomatic improvement; quality of life scores improved in 19 of 27 patients (p = 0.002); dyspnea scores improved in 22 of 24 patients (p = 0.001); functional status scores improved in 18 of 26 patients (p = 0.002); and mean exercise capacity improved from baseline, although not significantly. The 49 complications included mainly 21 partial stent obstructions, 14 infections, and 10 stent migrations. Most patients with concomitant COPD also improved on most measures. In the short term, airway stabilization with silicone stents in patients with severe TBM can improve respiratory symptoms, quality of life, and functional status. Coexisting COPD is not an absolute contraindication to a stenting trial in this population. Stenting is associated with a high number of short-term and long-term but generally reversible complications.

  14. Drug eluting balloons for de novo coronary lesions – a systematic review and meta-analysis

    PubMed Central

    2013-01-01

    Background The role of drug-eluting balloons (DEB) is unclear. Increasing evidence has shown a benefit for the treatment of in-stent restenosis. Its effect on de novo coronary lesions is more controversial. Several smaller randomized trials found conflicting results. Methods This is a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the effect of local Paclitaxel delivery/drug eluting balloons (DEB) (+/− bare metal stent) compared to current standard therapy (stenting) to treat de novo coronary lesions. Data sources for RCT were identified through a literature search from 2005 through 28 December 2012. The main endpoints of interest were target lesion revascularization (TLR), major adverse cardiac events (MACE), binary in-segment restenosis, stent thrombosis (ST), myocardial infarction (MI), late lumen loss (LLL) and mortality. A random effects model was used to calculate the pooled relative risks (RR) with 95% confidence intervals. Results Eight studies (11 subgroups) and a total of 1,706 patients were included in this analysis. Follow-up duration ranged from 6 to 12 months. Overall, DEB showed similar results to the comparator treatment. The relative risk (RR) for MACE was 0.95 (0.64 to 1.39); P = 0.776, for mortality it was 0.79 (0.30 to 2.11), P = 0.644, for stent thrombosis it was 1.45 (0.42 to 5.01), P = 0.560, for MI it was 1.26 (0.49 to 3.21), P = 0.629, for TLR it was 1.09 (0.71 to 1.68); P = 0.700 and for binary in-stent restenosis it was 0.96 (0.48 to 1.93), P = 0.918. Compared to bare metal stents (BMS), DEB showed a lower LLL (− 0.26 mm (−0.51 to 0.01)) and a trend towards a lower MACE risk (RR 0.66 (0.43 to 1.02)). Conclusion Overall, drug-eluting balloons (+/− bare metal stent) are not superior to current standard therapies (BMS or drug eluting stent (DES)) in treating de novo coronary lesions. However, the performance of DEB seems to lie in between DES and BMS with a trend towards superiority over BMS alone. Therefore, DEB may be considered in patients with contraindications for DES. The heterogeneity between the included studies is a limitation of this meta-analysis; different drug-eluting balloons have been used. PMID:23657123

  15. Intraoperative and postoperative feasibility and safety of total tubeless, tubeless, small-bore tube, and standard percutaneous nephrolithotomy: a systematic review and network meta-analysis of 16 randomized controlled trials.

    PubMed

    Lee, Joo Yong; Jeh, Seong Uk; Kim, Man Deuk; Kang, Dong Hyuk; Kwon, Jong Kyou; Ham, Won Sik; Choi, Young Deuk; Cho, Kang Su

    2017-06-27

    Percutaneous nephrolithotomy (PCNL) is performed to treat relatively large renal stones. Recent publications indicate that tubeless and total tubeless (stentless) PCNL is safe in selected patients. We performed a systematic review and network meta-analysis to evaluate the feasibility and safety of different PCNL procedures, including total tubeless, tubeless with stent, small-bore tube, and large-bore tube PCNLs. PubMed, Cochrane Central Register of Controlled Trials, and EMBASE™ databases were searched to identify randomized controlled trials published before December 30, 2013. One researcher examined all titles and abstracts found by the searches. Two investigators independently evaluated the full-text articles to determine whether those met the inclusion criteria. Qualities of included studies were rated with Cochrane's risk-of-bias assessment tool. Sixteen studies were included in the final syntheses including pairwise and network meta-analyses. Operation time, pain scores, and transfusion rates were not significantly different between PCNL procedures. Network meta-analyses demonstrated that for hemoglobin changes, total tubeless PCNL may be superior to standard PCNL (mean difference [MD] 0.65, 95% CI 0.14-1.13) and tubeless PCNLs with stent (MD -1.14, 95% CI -1.65--0.62), and small-bore PCNL may be superior to tubeless PCNL with stent (MD 1.30, 95% CI 0.27-2.26). Network meta-analyses also showed that for length of hospital stay, total tubeless (MD 1.33, 95% CI 0.23-2.43) and tubeless PCNLs with stent (MD 0.99, 95% CI 0.19-1.79) may be superior to standard PCNL. In rank probability tests, small-bore tube and total tubeless PCNLs were superior for operation time, pain scores, and hemoglobin changes. For hemoglobin changes, total tubeless and small-bore PCNLs may be superior to other methods. For hospital stay, total tubeless and tubeless PCNLs with stent may be superior to other procedures.

  16. Comparison of Short- and Long-Term Cardiac Mortality in Early Versus Late Stent Thrombosis (from Pooled PROTECT Trials).

    PubMed

    Secemsky, Eric A; Matteau, Alexis; Yeh, Robert W; Steg, Philippe Gabriel; Camenzind, Edoardo; Wijns, William; McFadden, Eugene; Mauri, Laura

    2015-06-15

    Studies have indicated varying mortality risks with timing of stent thrombosis (ST), but few have been adequately powered with prospective late follow-up. PROTECT randomized 8,709 subjects to either Endeavor zotarolimus-eluting or Cypher sirolimus-eluting stents. PROTECT Continued Access enrolled 1,018 patients treated with Endeavor zotarolimus-eluting stents. Subjects completed at least 4 and 3 years of follow-up, respectively. ARC-defined definite and probable ST events were stratified by time from index procedure: early (≤30 days), late (>30 and ≤360 days), and very late (>360 days). Rates of death and myocardial infarction were analyzed by ST timing. Median follow-up was 4.1 years. There were 184 ST events (1.9%): 61 early, 27 late, and 96 very late. Patient and procedural characteristics were similar between timing groups. There was no difference in dual-antiplatelet therapy use at discharge (97%) or 1 year (84%). Cardiac death in patients with ST at 4 years occurred in 32.1% compared with 2.5% in patients without ST (p <0.001). Combined rates of cardiac death and myocardial infarction did not differ according to ST timing, yet early ST was more commonly associated with cardiac death at 4 years than later ST (50.8% for early vs 18.5% for late vs 24.0% for very late; p <0.001). The relation between ST timing and outcomes did not differ between stent types. In conclusion, in prospective data, cardiac death was more common after early ST than later ST. Although ST remains infrequent, continued efforts to determine how to reduce ST, particularly within the first 30 days, are warranted. (The PROTECT trial is registered with ClinicalTrials.gov, number NCT00476957.). Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    PubMed

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  18. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    PubMed

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  19. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography

    PubMed Central

    Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870

  20. Drug-eluting stent thrombosis: results from the multicenter Spanish registry ESTROFA (Estudio ESpañol sobre TROmbosis de stents FArmacoactivos).

    PubMed

    de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa

    2008-03-11

    This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.

  1. Effectiveness and safety of drug-eluting stents in Ontario.

    PubMed

    Tu, Jack V; Bowen, James; Chiu, Maria; Ko, Dennis T; Austin, Peter C; He, Yaohua; Hopkins, Robert; Tarride, Jean-Eric; Blackhouse, Gord; Lazzam, Charles; Cohen, Eric A; Goeree, Ron

    2007-10-04

    The placement of drug-eluting stents decreases the frequency of repeat revascularization procedures in patients undergoing percutaneous coronary intervention (PCI) in randomized clinical trials. However, there is uncertainty about the effectiveness of drug-eluting stents, and increasing concern about their safety, in routine clinical practice. From the Cardiac Care Network of Ontario's population-based clinical registry of all patients undergoing PCI in Ontario, Canada, we identified a well-balanced cohort of 3751 pairs of patients, matched on the basis of propensity score, who received either bare-metal stents alone or drug-eluting stents alone during an index PCI procedure between December 1, 2003, and March 31, 2005. The primary outcomes of the study were the rates of target-vessel revascularization, myocardial infarction, and death. The 2-year rate of target-vessel revascularization was significantly lower among patients who received drug-eluting stents than among those who received bare-metal stents (7.4% vs. 10.7%, P<0.001). Drug-eluting stents were associated with significant reductions in the rate of target-vessel revascularization among patients with two or three risk factors for restenosis (i.e., presence of diabetes, small vessels [<3 mm in diameter], and long lesions [> or =20 mm]) but not among lower-risk patients. The 3-year mortality rate was significantly higher in the bare-metal-stent group than in the drug-eluting-stent group (7.8% vs. 5.5%, P<0.001), whereas the 2-year rate of myocardial infarction was similar in the two groups (5.2% and 5.7%, respectively; P=0.95). Drug-eluting stents are effective in reducing the need for target-vessel revascularization in patients at highest risk for restenosis, without a significantly increased rate of death or myocardial infarction. Copyright 2007 Massachusetts Medical Society.

  2. Comparison of the influence of plastic and fully covered metal biliary stents on the accuracy of EUS-FNA for the diagnosis of pancreatic cancer.

    PubMed

    Siddiqui, Ali A; Fein, Michael; Kowalski, Thomas E; Loren, David E; Eloubeidi, Mohamad A

    2012-09-01

    Prior studies have reported that the presence of prior biliary stent may interfere with EUS visualization of pancreatic tumors. We aimed to compare the influence of the biliary plastic and fully covered self-expanding metal stents (CSEMS) on the accuracy of EUS-FNA cytology in patients with solid pancreatic masses. We conducted a retrospective study evaluating 677 patients with solid pancreatic head/uncinate lesions and a previous biliary stent in whom EUS-FNA was performed. The patients were stratified into two groups: (1) those with a plastic stents and (2) those with CSEMS. Performance characteristics of EUS-FNA including the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were compared between the two groups. The frequency of obtaining an adequate cytology by EUS-FNA was similar in both the CSEMS group and the plastic stent group (97 vs. 97.1 % respectively; p = 1.0). The sensitivity, specificity, and accuracy of EUS-FNA was not significantly different between patients with CSEMS and plastic stents (96.8, 100, 100 % and 97.3, 98, 99.8 %, respectively). The negative predictive value for EUS-FNA was lower in the CSEMS group compared to the plastic stent group (66.6 vs. 78.1 % respectively; p = 0.42). There was one false-positive cytology in the plastic stent group compared to none in the CSEMS group. In a retrospective cohort trial, EUS-FNA was found to be highly accurate and safe in diagnosing patients with suspected pancreatic cancer, even in the presence of a plastic or metallic biliary stent. The presence of a stent did not contribute to a higher false-positive cytology rate.

  3. A randomized controlled trial of a middle meatal silastic stent for reducing adhesions and middle turbinate lateralization following endoscopic sinus surgery.

    PubMed

    Chan, Chun L; Elmiyeh, Behrad; Woods, Charmaine; Ullah, Shahid; Gunawardena, Indunil; Carney, A Simon; Ooi, Eng H

    2015-06-01

    Endoscopic sinus surgery (ESS) is indicated for patients with recalcitrant chronic rhinosinusitis symptoms. However, surgical revision can be required because of adhesion formation and middle turbinate lateralization. We investigate the efficacy of a middle meatal silastic stent in reducing these complications after ESS. Thirty-six patients were randomized to receive a silastic stent in the middle meatus unilaterally after ESS. The surgeon was blinded to the side receiving the stent until completion of the ESS. The contralateral side, with no stent, was the control side. Patients completed a 7-day, postoperative, visual analog scale symptom diary and were blinded to the stent side until its removal at the first postoperative visit. Patients were followed up after 2, 8, and 24 weeks. Endoscopic video of the sinus cavities were recorded at all visits and 2 blinded, independent ear/nose/throat (ENT) surgeons assessed the videos using a modified Lund-Kennedy scoring system. Thirty-five of 36 patients completed 6-months' follow-up. Middle turbinate lateralization was observed in 13 sides without a stent vs 1 side with a stent. There was a significant reduction in adhesions at weeks 2 and 8 (p < 0.001) and crusting (p < 0.01) in the stent side compared to control. Video scores at 6 months after surgery for stent and control sides remained unchanged from the 8-week visit. There was no difference between sides for symptom scores, edema, or nasal discharge. Middle meatal silastic stents are well tolerated by patients and effective in reducing middle turbinate lateralization, adhesions, and crusting postoperatively in ESS. © 2015 ARS-AAOA, LLC.

  4. Carotid Disease Management: Surgery, Stenting, or Medication.

    PubMed

    Khandelwal, Priyank; Chaturvedi, Seemant

    2015-09-01

    Internal carotid artery stenosis accounts for about 7-10 % of ischemic strokes. Conventional risk factors such as aging, hypertension, diabetes mellitus, and smoking increase the risk for carotid atherosclerosis. All patients with carotid stenosis should receive aggressive medical therapy. Carotid revascularization with either endarterectomy or stenting can benefit select patients with severe stenosis. New clinical trials will examine the contemporary role of carotid revascularization relative to optimal medical therapy.

  5. Comparative Analysis of Sequential Proximal Optimizing Technique Versus Kissing Balloon Inflation Technique in Provisional Bifurcation Stenting: Fractal Coronary Bifurcation Bench Test.

    PubMed

    Finet, Gérard; Derimay, François; Motreff, Pascal; Guerin, Patrice; Pilet, Paul; Ohayon, Jacques; Darremont, Olivier; Rioufol, Gilles

    2015-08-24

    This study used a fractal bifurcation bench model to compare 6 optimization sequences for coronary bifurcation provisional stenting, including 1 novel sequence without kissing balloon inflation (KBI), comprising initial proximal optimizing technique (POT) + side-branch inflation (SBI) + final POT, called "re-POT." In provisional bifurcation stenting, KBI fails to improve the rate of major adverse cardiac events. Proximal geometric deformation increases the rate of in-stent restenosis and target lesion revascularization. A bifurcation bench model was used to compare KBI alone, KBI after POT, KBI with asymmetric inflation pressure after POT, and 2 sequences without KBI: initial POT plus SBI, and initial POT plus SBI with final POT (called "re-POT"). For each protocol, 5 stents were tested using 2 different drug-eluting stent designs: that is, a total of 60 tests. Compared with the classic KBI-only sequence and those associating POT with modified KBI, the re-POT sequence gave significantly (p < 0.05) better geometric results: it reduced SB ostium stent-strut obstruction from 23.2 ± 6.0% to 5.6 ± 8.3%, provided perfect proximal stent apposition with almost perfect circularity (ellipticity index reduced from 1.23 ± 0.02 to 1.04 ± 0.01), reduced proximal area overstretch from 24.2 ± 7.6% to 8.0 ± 0.4%, and reduced global strut malapposition from 40 ± 6.2% to 2.6 ± 1.4%. In comparison with 5 other techniques, the re-POT sequence significantly optimized the final result of provisional coronary bifurcation stenting, maintaining circular geometry while significantly reducing SB ostium strut obstruction and global strut malapposition. These experimental findings confirm that provisional stenting may be optimized more effectively without KBI using re-POT. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Costs and cost-effectiveness of carotid stenting versus endarterectomy for patients at standard surgical risk: results from the Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST).

    PubMed

    Vilain, Katherine R; Magnuson, Elizabeth A; Li, Haiyan; Clark, Wayne M; Begg, Richard J; Sam, Albert D; Sternbergh, W Charles; Weaver, Fred A; Gray, William A; Voeks, Jenifer H; Brott, Thomas G; Cohen, David J

    2012-09-01

    The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) demonstrated similar rates of the primary composite end point between carotid artery stenting (CAS) and carotid endarterectomy (CEA), although the risk of stroke was higher with CAS, and the risk of myocardial infarction was higher with CEA. Given the large number of patients who are candidates for these procedures, an understanding of their relative cost and cost-effectiveness may have important implications for health care policy and treatment guidelines. We performed a formal economic evaluation alongside the CREST trial. Costs were estimated from all trial participants over the first year of follow-up using a combination of resource use data and hospital billing data. Patient-level health use scores were obtained using data from the SF-36. We then used a Markov disease-simulation model calibrated to the CREST results to project 10-year costs and quality-adjusted life expectancy for the 2 treatment groups. Although initial procedural costs were $1025/patient higher with CAS, postprocedure costs and physician costs were lower such that total costs for the index hospitalization were similar for the CAS and CEA groups ($15 055 versus $14 816; mean difference, $239/patient; 95% CI for difference, -$297 to $775). Neither follow-up costs after discharge nor total 1-year costs differed significantly. For the CREST population, model-based projections over a 10-year time horizon demonstrated that CAS would result in a mean incremental cost of $524/patient and a reduction in quality-adjusted life expectancy of 0.008 years compared with CEA. Probabilistic sensitivity analysis demonstrated that CEA was economically attractive at an incremental cost-effectiveness threshold of $50 000/quality-adjusted life-year gained in 54% of samples, whereas CAS was economically attractive in 46%. Despite slightly lower in-trial costs and lower rates of stroke with CEA compared with CAS, projected 10-year outcomes from this controlled clinical trial demonstrate only trivial differences in overall healthcare costs and quality-adjusted life expectancy between the 2 strategies. If the CREST results can be replicated in clinical practice, these findings suggest that factors other than cost-effectiveness should be considered when deciding between treatment options for carotid artery stenosis in patients at standard risk for surgical complications. Clinical Trial Registration- URL: http://clinicaltrials.gov. Unique Identifier: NCT00004732.

  7. EXCEL Clinical Trial

    ClinicalTrials.gov

    2018-03-01

    Chronic Coronary Occlusion; Unprotected Left Main Coronary Artery Disease; Stent Thrombosis; Vascular Disease; Myocardial Ischemia; Coronary Artery Stenosis; Coronary Disease; Coronary Artery Disease; Coronary Restenosis

  8. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    PubMed

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  9. Restenosis and risk of stroke after stenting or endarterectomy for symptomatic carotid stenosis in the International Carotid Stenting Study (ICSS): secondary analysis of a randomised trial.

    PubMed

    Bonati, Leo H; Gregson, John; Dobson, Joanna; McCabe, Dominick J H; Nederkoorn, Paul J; van der Worp, H Bart; de Borst, Gert J; Richards, Toby; Cleveland, Trevor; Müller, Mandy D; Wolff, Thomas; Engelter, Stefan T; Lyrer, Philippe A; Brown, Martin M

    2018-05-31

    The risk of stroke associated with carotid artery restenosis after stenting or endarterectomy is unclear. We aimed to compare the long-term risk of restenosis after these treatments and to investigate if restenosis causes stroke in a secondary analysis of the International Carotid Stenting Study (ICSS). ICSS is a parallel-group randomised trial at 50 tertiary care centres in Europe, Australia, New Zealand, and Canada. Patients aged 40 years or older with symptomatic carotid stenosis measuring 50% or more were randomly assigned either stenting or endarterectomy in a 1:1 ratio. Randomisation was computer-generated and done centrally, with allocation by telephone or fax, stratified by centre, and with minimisation for sex, age, side of stenosis, and occlusion of the contralateral carotid artery. Patients were followed up both clinically and with carotid duplex ultrasound at baseline, 30 days after treatment, 6 months after randomisation, then annually for up to 10 years. We included patients whose assigned treatment was completed and who had at least one ultrasound examination after treatment. Restenosis was defined as any narrowing of the treated artery measuring 50% or more (at least moderate) or 70% or more (severe), or occlusion of the artery. The degree of restenosis based on ultrasound velocities and clinical outcome events were adjudicated centrally; assessors were masked to treatment assignment. Restenosis was analysed using interval-censored models and its association with later ipsilateral stroke using Cox regression. This trial is registered with the ISRCTN registry, number ISRCTN25337470. This report presents a secondary analysis, and follow-up is complete. Between May, 2001, and October, 2008, 1713 patients were enrolled and randomly allocated treatment (855 were assigned stenting and 858 endarterectomy), of whom 1530 individuals were followed up with ultrasound (737 assigned stenting and 793 endarterectomy) for a median of 4·0 years (IQR 2·3-5·0). At least moderate restenosis (≥50%) occurred in 274 patients after stenting (cumulative 5-year risk 40·7%) and in 217 after endarterectomy (29·6%; unadjusted hazard ratio [HR] 1·43, 95% CI 1·21-1·72; p<0·0001). Patients with at least moderate restenosis (≥50%) had a higher risk of ipsilateral stroke than did individuals without restenosis in the overall patient population (HR 3·18, 95% CI 1·52-6·67; p=0·002) and in the endarterectomy group alone (5·75, 1·80-18·33; p=0·003), but no significant increase in stroke risk after restenosis was recorded in the stenting group (2·03, 0·77-5·37; p=0·154; p=0·10 for interaction with treatment). No difference was noted in the risk of severe restenosis (≥70%) or subsequent stroke between the two treatment groups. At least moderate (≥50%) restenosis occurred more frequently after stenting than after endarterectomy and increased the risk for ipsilateral stroke in the overall population. Whether the restenosis-mediated risk of stroke differs between stenting and endarterectomy requires further research. Medical Research Council, the Stroke Association, Sanofi-Synthélabo, and the European Union. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access Article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  10. Tube focal spot size and power capability impact image quality in the evaluation of intracoronary stents

    NASA Astrophysics Data System (ADS)

    Cesmeli, Erdogan; Berry, Joel L.; Carr, J. J.

    2005-04-01

    Proliferation of coronary stent deployment for treatment of coronary heart disease (CHD) creates a need for imaging-based follow-up examinations to assess patency. Technological improvements in multi-detector computer tomography (MDCT) make it a potential non-invasive alternative to coronary catheterization for evaluation of stent patency; however, image quality with MDCT varies based on the size and composition of the stent. We studied the role of tube focal spot size and power in the optimization of image quality in a stationary phantom. A standard uniform physical phantom with a tubular insert was used where coronary stents (4 mm in diameter) were deployed in a tube filled with contrast to simulate a typical imaging condition observed in clinical practice. We utilized different commercially available stents and scanned them with different tube voltage and current settings (LightSpeed Pro16, GE Healthcare Technologies, Waukesha, WI, USA). The scanner used different focal spot size depending on the power load and thus allowed us to assess the combined effect of the focal spot size and the power. A radiologist evaluated the resulting images in terms of image quality and artifacts. For all stents, we found that the small focal spot size yielded better image quality and reduced artifacts. In general, higher power capability for the given focal spot size improved the signal-to-noise ratio in the images allowing improved assessment. Our preliminary study in a non-moving phantom suggests that a CT scanner that can deliver the same power on a small focal spot size is better suited to have an optimized scan protocol for reliable stent assessment.

  11. Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

    PubMed

    Kang, Si-Hyuck; Park, Kyung Woo; Kang, Do-Yoon; Lim, Woo-Hyun; Park, Kyung Taek; Han, Jung-Kyu; Kang, Hyun-Jae; Koo, Bon-Kwon; Oh, Byung-Hee; Park, Young-Bae; Kandzari, David E; Cohen, David J; Hwang, Seung-Sik; Kim, Hyo-Soo

    2014-05-01

    The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. Study stents included BMS, paclitaxel-eluting (PES), sirolimus-eluting (SES), endeavor zotarolimus-eluting (ZES-E), cobalt-chromium everolimus-eluting (CoCr-EES), platinium-chromium everolimus-eluting (PtCr-EES), resolute zotarolimus-eluting (ZES-R), and BP biolimus-eluting stents (BP-BES). After a systematic electronic search, 113 trials with 90 584 patients were selected. The principal endpoint was definite or probable stent thrombosis (ST) defined according to the Academic Research Consortium within 1 year. Biodegradable polymer-biolimus-eluting stents [OR, 0.56; 95% credible interval (CrI), 0.33-0.90], SES (OR, 0.53; 95% CrI, 0.38-0.73), CoCr-EES (OR, 0.34; 95% CrI, 0.23-0.52), and PtCr-EES (OR, 0.31; 95% CrI, 0.10-0.90) were all superior to BMS in terms of definite or probable ST within 1 year. Cobalt-chromium everolimus-eluting stents demonstrated the lowest risk of ST of all stents at all times after stent implantation. Biodegradable polymer-biolimus-eluting stents was associated with a higher risk of definite or probable ST than CoCr-EES (OR, 1.72; 95% CrI, 1.04-2.98). All DES reduced the need for repeat revascularization, and all but PES reduced the risk of myocardial infarction compared with BMS. All DESs but PES and ZES-E were superior to BMS in terms of ST within 1 year. Cobalt-chromium everolimus-eluting stents was safer than any DES even including BP-BES. Our results suggest that not only the biodegradability of polymer, but the optimal combination of stent alloy, design, strut thickness, polymer, and drug all combined determine the safety of DES.

  12. Neuropsychological outcome after percutaneous coronary intervention or coronary artery bypass grafting: results from the Stent or Surgery (SoS) Trial.

    PubMed

    Währborg, Peter; Booth, Jean E; Clayton, Tim; Nugara, Fiona; Pepper, John; Weintraub, William S; Sigwart, Ulrich; Stables, Rod H

    2004-11-30

    Coronary artery bypass surgery (CABG) has been associated with a range of neurological and neuropsychological complications from stroke to cognitive problems such as memory and problem solving disturbance. However, little is known about the impact of percutaneous coronary intervention (PCI) on neuropsychological outcome. In the Stent or Surgery Trial (SoS), 988 patients were randomized in equal proportions between PCI supported by stent implantation and CABG. As a substudy of this trial, we undertook an evaluation of neurological and neuropsychological outcomes after intervention. A clinical examination and neuropsychological assessment consisting of 5 tests (Digit Span Forwards and Backwards, Visual Reproduction, Bourdon, and Block Design) were performed at baseline and 6 and 12 months after the procedure. A total of 145 patients were included in the substudy analysis: 77 in the PCI group and 68 in the CABG group. One patient in the PCI arm had a stroke. There was no significant difference between treatment groups at 6 and 12 months for any of the 5 tests. The mean change from baseline was also similar in both groups. We were not able to demonstrate an important and significant difference in neuropsychological outcome in patients treated with different revascularization strategies. This important finding needs to be examined in further research.

  13. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    PubMed

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study to demonstrate superiority of ELA + PTA versus PTA alone for treating femoropopliteal ISR. (Randomized Study of Laser and Balloon Angioplasty Versus Balloon Angioplasty to Treat Peripheral In-stent Restenosis [EXCITE ISR]; NCT01330628). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Rationale and design of a multidisciplinary national real-world registry on carotid stenting: the Italian Registry for Carotid Stenting (RISC).

    PubMed

    Biasi, Giorgio M; Deleo, Gaetano; Froio, Alberto; Cremonesi, Alberto; Inglese, Luigi; Lavitrano, Marialuisa; Setacci, Carlo

    2006-04-01

    The Registro Italiano per lo Stenting Carotideo (RISC, Italian Registry for Carotid Stenting) has been organized by Italian specialists from different disciplines directly involved in the prevention of stroke due to carotid plaques through stenting of carotid lesions. The Registry has been endorsed by the national societies of 4 different specialties: vascular surgery, interventional cardiology, radiology, and neuroradiology. Each society contributed in the planning stage. The basis for the registry is to collect data on carotid stenting procedures performed by different specialists with different techniques in a "real-world" setting without the limitations of a randomized clinical trial. The Registry was funded to enroll at least 1200 patients over a minimum period of 36 months. The results will be analyzed using the intention-to-treat principle and are anticipated in late 2006. Primary endpoints of the registry are the 30-day combined death and stroke rate and the occurrence of restenosis and ipsilateral neurological deficit at 12 and 24 months. Considerable attention has been paid to the registry's quality control program to ensure scientific validation. An online database facilitates the collection of data with speed and accuracy.

  15. Meta-analysis of long-term clinical outcomes of everolimus-eluting stents.

    PubMed

    Toyota, Toshiaki; Shiomi, Hiroki; Morimoto, Takeshi; Kimura, Takeshi

    2015-07-15

    The superiority of everolimus-eluting stents (EES) over sirolimus-eluting stents (SES) for long-term clinical outcomes has not been yet firmly established. We conducted a systematic review and a meta-analysis of randomized controlled trials (RCTs) comparing EES directly with SES using the longest available follow-up data. We searched PubMed, the Cochrane database, and ClinicalTrials.gov for RCTs comparing outcomes between EES and SES and identified 13,434 randomly assigned patients from 14 RCTs. EES was associated with significantly lower risks than SES for definite stent thrombosis (ST), definite/probable ST, target-lesion revascularization (TLR), and major adverse cardiac events (MACE). The risks for all-cause death and myocardial infarction were similar between EES and SES. By the stratified analysis according to the timing after stent implantation, the favorable trend of EES relative to SES for ST, TLR, and MACE was consistently observed both within and beyond 1 year. The lower risk of EES relative to SES for MACE beyond 1 year was statistically significant (pooled odds ratio 0.77, 95% confidence interval 0.61 to 0.96, p = 0.02). In conclusion, the current meta-analysis of 14 RCTs directly comparing EES with SES suggested that EES provided improvement in both safety and efficacy; EES compared with SES was associated with significantly lower risk for definite ST, definite/probable ST, TLR, and MACE. The direction and magnitude of the effect beyond 1 year were comparable with those observed within 1 year. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Feasibility of placing a modified fully covered self-expandable metal stent above the papilla to minimize stent-induced bile duct injury in patients with refractory benign biliary strictures (with videos).

    PubMed

    Moon, Jong Ho; Choi, Hyun Jong; Koo, Hyun Cheol; Han, Seung Hyo; Lee, Tae Hoon; Cho, Young Deok; Park, Sang-Heum; Kim, Sun-Joo

    2012-05-01

    Endoscopic placement of fully covered self-expandable metal stents (FCSEMS) has been attempted to manage benign biliary strictures, but currently available FCSEMSs may be associated with unintended complications, including de novo strictures, in patients with normal life expectancy. To evaluate the feasibility of an intraductally placed modified FCSEMS to minimize stent-induced bile duct injury in patients with benign biliary strictures. Prospective observational clinical feasibility study. Tertiary-care academic center. This study involved 21 patients with symptomatic benign biliary strictures in whom conventional endoscopic management failed. Strictured segments were 15 mm above the ampulla of Vater. The modified FCSEMS has convex margins, a lasso, and an anti-migrating waist on the central portion. Stents were placed entirely above the papilla and removed after 3 to 5 months. Success, complications, removability, midterm outcome. FCSEMSs were successfully placed inside the bile duct in all patients. No episodes of pancreatitis, cholangitis, or sepsis were noted during the stenting period. Stent migration occurred in 4 patients (19.0%), but 3 were asymptomatic during follow-up. All stents were removed successfully with rat-tooth forceps without complications. Post-stenting cholangiograms showed improvement of strictures in 20 of 21 patients, without de novo focal stricture. The clinical success rate was 95.2%, with one recurrent stricture. The small number and lack of comparison with other types of FCSEMSs. Temporary intraductal placement of a newly modified FCSEMS effectively improved strictures and prevented potential stent-induced complications in patients with benign biliary strictures. Controlled large-scale trials are needed to confirm the long-term efficacy. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Dilation or biodegradable stent placement for recurrent benign esophageal strictures: a randomized controlled trial.

    PubMed

    Walter, Daisy; van den Berg, Maarten W; Hirdes, Meike M; Vleggaar, Frank P; Repici, Alessandro; Deprez, Pierre H; Viedma, Bartolomé L; Lovat, Laurence B; Weusten, Bas L; Bisschops, Raf; Haidry, Rehan; Ferrara, Elisa; Sanborn, Keith J; O'Leary, Erin E; van Hooft, Jeanin E; Siersema, Peter D

    2018-06-08

     Dilation is the standard of care for recurrent benign esophageal strictures (BES). Biodegradable stents may prolong the effect of dilation and reduce recurrences. Efficacy and safety of dilation and biodegradable stent placement early in the treatment algorithm of recurrent BES were compared.  This multicenter, randomized study enrolled patients with BES treated with previous dilations to ≥ 16 mm. The primary end point was number of repeat endoscopic dilations for recurrent stricture within 3 and 6 months. Secondary outcomes through 12 months included safety, time to first dilation for recurrent stricture, dysphagia, and level of activity.  At 3 months, the biodegradable stent group (n = 32) underwent significantly fewer endoscopic dilations for recurrent stricture compared with the dilation group (n = 34; P  < 0.001). By 6 months, the groups were similar. The number of patients experiencing adverse events was similar between the groups. Two patients in the biodegradable stent group died after developing tracheoesophageal fistulas at 95 and 96 days post-placement; no deaths were attributed to the stent. Median time to first dilation of recurrent stricture for the biodegradable stent group was significantly longer (106 vs. 41.5 days; P  = 0.003). Dysphagia scores improved for both groups. Patients in the biodegradable stent group had a significantly higher level of activity through 12 months ( P  < 0.001).  Biodegradable stent placement is associated with temporary reduction in number of repeat dilations and prolonged time to recurrent dysphagia compared with dilation. Additional studies are needed to better define the exact role of biodegradable stent placement to treat recurrent BES. © Georg Thieme Verlag KG Stuttgart · New York.

  18. A preliminary report on the effects of paclitaxel-impregnated stents on sheep nasal mucosa.

    PubMed

    Herrmann, Brian W; Citardi, Martin J; Vogler, George; Gardner, Laura; Smith, Greg; Javer, Amin R; Burt, Helen M; Jackson, John; Kuhn, Frederick A

    2004-01-01

    Traditional frontal sinus stents serve only as mechanical devices. It has been proposed that stents also may serve as drug-delivery systems for the topical application of drugs that minimize postoperative scarring. Paclitaxel (Taxol), which has recognized antiscarring effects, may be incorporated via a polymeric formulation into standard rubber stents. The impact of topically applied paclitaxel on the morphology of the nasal mucosa is unknown. An adult sheep model was used for this study. A modified rubber T-tube stent (incorporating paclitaxel at varying dosages) was secured to each side of the septum in four animals (eight sides). An unmodified T-tube was placed on each side of one animal, a T-tube with the drug carrier (but no paclitaxel) was placed on each side of the second animal, and T-tubes with varying paclitaxel were placed on each side of the final two animals. After 4 weeks, animals were killed and the nasal mucosa was harvested. The nasal mucosa was sectioned and stained with hematoxylin and eosin. A pathologist then assessed the nasal mucosa for vascular congestion, glandular atrophy, chronic inflammation, mucosal metaplasia, and mucosal ulceration. No consistent histopathological differences were noted in the specimens. All specimens showed varying degrees of vascular congestion, glandular atrophy, chronic inflammation, and mucosal metaplasia; the paclitaxel-impregnated stents were not consistently associated with more severe mucosal injury. Finally, mucosal ulceration was noted to be very rare in all specimens. This preliminary report describes the impact of paclitaxel-impregnated stents on sheep nasal mucosa, which tolerated these stents very well. Because paclitaxel minimizes scarring reactions at very low concentrations, paclitaxel-impregnated stents may prove useful in clinical situations in which frontal sinus stenting is deemed necessary. Additional investigations with animal models, as well as clinical trials, may be warranted.

  19. A prospective study of external stenting of saphenous vein grafts to the right coronary artery: the VEST II study.

    PubMed

    Taggart, David P; Amin, Sanaz; Djordjevic, Jasmina; Oikonomou, Evangelos K; Thomas, Sheena; Kampoli, Anna-Maria; Sabharwal, Nikant; Antoniades, Charalambos; Krasopoulos, George

    2017-05-01

    External stents significantly reduce intimal hyperplasia and improve lumen uniformity and flow pattern in saphenous vein grafts (SVG) 1 year after coronary artery bypass grafting. However, recent studies have shown that at 1 year there is a lower patency of externally stented SVG to the right coronary artery (RCA) (55-60%) when compared to the left sided coronary arteries (85-90%). In the current study, we investigated whether avoidance of both fixation of the external stent to the anastomoses and the use of metal clips to ligate SVG side branches would improve the early patency of externally stented SVG to the RCA. Thirty patients received a SVG to the right territory supported with an external stent. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG patency assessed by computed tomography angiography (CTA) at 3-6 months. Graft failure was defined as > 50% stenosis. Twenty-nine patients (96.6%) completed the follow up period and CT angiography data was available for a total of 43 SVGs, (29 supported and 14 unsupported SVGs) and 47 arterial grafts. Patency of stented SVGs was 86.2% (25/29 on CTA). All non-stented SVGs to the left territory were patent. Patency rates of the left internal mammary arteries and right internal mammary arteries grafts were 96.6% and 83.3%, respectively. Avoidance of both metallic clips to ligate side branches and of fixation of venous external support trial (VEST) stents to the anastomoses mark a significant improvement in patency of stented SVG to the right coronary territory. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. The Management of Superior Mesenteric Artery Aneurysm: Experience with 16 Cases in a Single Center.

    PubMed

    Zilun, Li; Henghui, Yin; Yang, Zhao; Mian, Wang; Guangqi, Chang; Shenming, Wang

    2017-07-01

    Superior mesenteric artery aneurysm (SMAA) represents a rare but potentially fatal condition. This study aimed to present the individual management protocol of SMAA in our center and to discuss a potential preliminary treatment algorithm. SMAA patients treated in our center between January 2007 and December 2014 were retrospectively reviewed on January 2015. Sixteen patients with SMAA were identified, including 1 female and 15 males, with a mean age of 48.9 ± 12.9 years. Three patients (3/16, 18.8%) were treated by multiple overlapping bare stents and one (1/16, 6.3%) initially by a single bare stent. Two cases (2/16, 12.5%) were treated by a covered stent implantation, but one of those suffered from SMAA rupture 7 days later, whereas the other had inner-stent thrombosis one month after discharge and died from multiple organ-dysfunction syndrome. Nine patients (9/16, 56.2%) received conservative therapy, one of who received multiple overlapping bare stents implantations for persistent abdominal pain. One patient underwent open surgery. There were 2 major complications, with no death during hospitalization and 1 death during follow-up. SMAA treatment needs to be individually prescribed, based on clinical manifestation, anatomy, and etiology. Multiple overlapping bare stents are safe and effective in selective patients with SMAA, and covered stents should be used with caution to avoid covering proximal branches; open surgery should be reserved for patients with suspected intestinal necrosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration.

    PubMed

    Moon, Sung-Hoon; Kim, Myung-Hwan; Park, Do Hyun; Song, Tae Joon; Eum, Junbum; Lee, Sang Soo; Seo, Dong Wan; Lee, Sung Koo

    2010-07-01

    Fully covered self-expandable metal stent (FCSEMS) placement has recently been tried in the management of refractory pancreatic-duct strictures associated with advanced chronic pancreatitis. The major limitation of FCSEMSs was frequent migration. To assess the safety, migration rate, and removability of modified FCSEMSs with antimigration features used for the treatment of benign pancreatic-duct strictures. Prospective study. Tertiary academic center. Thirty-two patients with chronic painful pancreatitis and dominant ductal stricture. Transpapillary endoscopic placement of FCSEMSs in the pancreatic duct with removal after 3 months. Technical and functional success and adverse events associated with the placement of metal stents. FCSEMSs were successfully placed in all patients through the major (n = 27) or minor (n = 5) duodenal papilla. All patients achieved pain relief from stent placement. There was no occurrence of stent-induced pancreatitis or pancreatic sepsis. No stent migrated, and all stents were easily removed. Follow-up ERCP 3 months after stent placement showed resolution of duct strictures in all patients. Pancreatograms obtained at FCSEMS removal displayed de novo focal pancreatic duct strictures in 5 patients, but all were asymptomatic. No long-term follow-up. Temporary 3-month placement of FCSEMSs was effective in resolving pancreatic-duct strictures in chronic pancreatitis, with an acceptable morbidity profile. Modified FCSEMSs can prevent stent migration, but may be associated with de novo duct strictures. Further trials are needed to assess long-term safety and efficacy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. Orbital Atherectomy for Treating De Novo Severely Calcified Coronary Narrowing (1-Year Results from the Pivotal ORBIT II Trial).

    PubMed

    Généreux, Philippe; Lee, Arthur C; Kim, Christopher Y; Lee, Michael; Shlofmitz, Richard; Moses, Jeffrey W; Stone, Gregg W; Chambers, Jeff W

    2015-06-15

    Percutaneous coronary intervention of severely calcified lesions has historically been associated with major adverse cardiac event (MACE) rates as high as 30%. In the ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial, treatment of de novo severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) resulted in low rates of procedural and 30-day adverse ischemic events. The long-term results from this trial have not been reported. We sought to determine the 1-year outcomes after orbital atherectomy of severely calcified coronary lesions. ORBIT II was a single-arm trial enrolling 443 subjects at 49 US sites with severely calcified lesions usually excluded from randomized trials. OAS utilizes a centrifugal differential sanding mechanism of action for plaque modification prior to stent implantation. After OAS drug-eluting stents were implanted in 88.2% of the patients. The primary safety end point was 30-day MACE, the composite of cardiac death, myocardial infarction, or target vessel revascularization [TVR]. The present analysis reports the 1-year follow-up results from ORBIT II. One-year data were available in 433 of 443 patients (97.7%), with median follow-up time of 16.7 months. The 1-year MACE rate was 16.4%, including cardiac death (3.0%), myocardial infarction (9.7%), and target vessel revascularization (5.9%). The 1-year target lesion revascularization rate was 4.7%, and stent thrombosis occurred in 1 patient (0.2%). Independent predictors of 1-year MACE and target vessel revascularization were diameter stenosis at baseline and the use of bare-metal stents. In patients with severely calcified lesions who underwent percutaneous coronary intervention, the use of OAS was associated with low rates of 1-year adverse ischemic events compared with historical controls. This finding has important clinical implications for the selection of optimum treatment strategies for patients with severely calcified lesions. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Metallic stents in the management of ureteric strictures

    PubMed Central

    Kulkarni, Ravi

    2014-01-01

    Management of ureteric strictures is a challenging task. Subtle presentation, silent progression and complex aetiology may delay diagnosis. A wide range of available treatment options combined with the lack of adequate randomised trials has led to the introduction of personal bias in the management of this difficult group of patients. Metallic ureteric stents offer an alternative to the conventional treatment modalities. A review of the currently available metallic stents and their role in the long-term management of ureteric strictures is presented. Materials used in the manufacture of indwelling urological devices are evolving all the time. Improved endo-urological techniques combined with new devices made from better compounds will continue to improve patient experience. PMID:24497686

  4. Indications and applications of arterial stents for stroke prevention in atherosclerotic intracranial stenosis.

    PubMed

    Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L

    2010-01-01

    Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.

  5. Bioresorbable Scaffolds: Current Evidences in the Treatment of Coronary Artery Disease

    PubMed Central

    2016-01-01

    Percutaneous coronary revascularization strategies have gradually progressed over a period of last few decades. The advent of newer generation drug-eluting stents has significantly improved the outcomes of Percutaneous Coronary Intervention (PCI) by substantially reducing in-stent restenosis and stent thrombosis. However, vascular inflammation, restenosis, thrombosis, and neoatherosclerosis due to the permanent presence of a metallic foreign body within the artery limit their usage in complex Coronary Artery Disease (CAD). Bioresorbable Scaffolds (BRS) represent a novel approach in coronary stent technology. Complete resorption of the scaffold liberates the treated vessel from its cage and restores pulsatility, cyclical strain, physiological shear stress, and mechanotransduction. In this review article, we describe the advances in this rapidly evolving technology, present the evidence from the pre-clinical and clinical evaluation of these devices, and provide an overview of the ongoing clinical trials that were designed to examine the effectiveness of BRS in the clinical setting. PMID:27891384

  6. Superficial Femoral Artery Intervention by Single Transpedal Arterial Access.

    PubMed

    Amoroso, Nicholas S; Shah, Sooraj; Liou, Michael; Ratcliffe, Justin; Lala, Moinakhtar; Diwan, Ravi; Huang, Yili; Rosero, Hugo; Coppola, John; Bertrand, Olivier F; Kwan, Tak W

    2015-11-01

    Atherosclerotic disease of the superficial femoral artery (SFA) is frequently seen and can be treated with percutaneous interventions, traditionally via femoral artery access. There are limited reports of transpedal artery access for peripheral artery interventions, but none to date describing routine primary transpedal artery approach for SFA stenting. In this preliminary study, we report 4 patients who underwent successful endovascular SFA stenting using a single transpedal artery access via a new ultra-low profile 6 Fr sheath (Glidesheath Slender; Terumo Corporation). All patients underwent successful SFA stenting without complication. Procedure time varied from 51 to 72 minutes. The mean contrast amount used was 56 mL; mean fluoroscopy time was 21 minutes; mean radiation dose was 91 mGy. At 1-month follow-up, duplex ultrasonography showed that all pedal arteries had remained patent. Transpedal artery approach as a primary approach to SFA stenting appears feasible and safe. Comparative trials with standard percutaneous femoral approach are warranted.

  7. Bioresorbable scaffolds in the treatment of coronary artery disease

    PubMed Central

    Zhang, Yaojun; Bourantas, Christos V; Farooq, Vasim; Muramatsu, Takashi; Diletti, Roberto; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Serruys, Patrick W

    2013-01-01

    Drug-eluting stents have reduced the risk of in-stent restenosis and have broadened the application in percutaneous coronary intervention in coronary artery disease. However, the concept of using a permanent metallic endovascular device to restore the patency of a stenotic artery has inherited pitfalls, namely the presence of a foreign body within the artery causing vascular inflammation, late complications such as restenosis and stent thrombosis, and impeding the restoration of the physiologic function of the stented segment. Bioresorbable scaffolds (BRS) were introduced to potentially overcome these limitations, as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage. Currently, several BRSs are available, undergoing evaluation either in clinical trials or in preclinical settings. The aim of this review is to present the new developments in BRS technology, describe the mechanisms involved in the resorption process, and discuss the potential future prospects of this innovative therapy. PMID:23662091

  8. A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results.

    PubMed

    Liu, Hai-bo; Xu, Bo; Qiao, Shu-bin; Yang, Yue-jin; Ma, Wei-hua; Qin, Xue-wen; Yao, Min; Wu, Yong-jian; Yuan, Jin-qing; Chen, Jue; You, Shi-jie; Dai, Jun; Xia, Ran; Li, Jian-jun; Chen, Ji-lin; Gao, Run-lin

    2007-04-05

    Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n = 93, Firebird group) or Excel stents (n = 97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups. Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P > 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 +/- 0.21) mm versus (0.14 +/- 0.20) mm (P = 0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nam, Hyeong Soo; Kim, Chang-Soo; Yoo, Hongki, E-mail: kjwmm@korea.ac.kr, E-mail: hyoo@hanyang.ac.kr

    Purpose: Intravascular optical coherence tomography (IV-OCT) is a high-resolution imaging method used to visualize the microstructure of arterial walls in vivo. IV-OCT enables the clinician to clearly observe and accurately measure stent apposition and neointimal coverage of coronary stents, which are associated with side effects such as in-stent thrombosis. In this study, the authors present an algorithm for quantifying stent apposition and neointimal coverage by automatically detecting lumen contours and stent struts in IV-OCT images. Methods: The algorithm utilizes OCT intensity images and their first and second gradient images along the axial direction to detect lumen contours and stent strutmore » candidates. These stent strut candidates are classified into true and false stent struts based on their features, using an artificial neural network with one hidden layer and ten nodes. After segmentation, either the protrusion distance (PD) or neointimal thickness (NT) for each strut is measured automatically. In randomly selected image sets covering a large variety of clinical scenarios, the results of the algorithm were compared to those of manual segmentation by IV-OCT readers. Results: Stent strut detection showed a 96.5% positive predictive value and a 92.9% true positive rate. In addition, case-by-case validation also showed comparable accuracy for most cases. High correlation coefficients (R > 0.99) were observed for PD and NT between the algorithmic and the manual results, showing little bias (0.20 and 0.46 μm, respectively) and a narrow range of limits of agreement (36 and 54 μm, respectively). In addition, the algorithm worked well in various clinical scenarios and even in cases with a low level of stent malapposition and neointimal coverage. Conclusions: The presented automatic algorithm enables robust and fast detection of lumen contours and stent struts and provides quantitative measurements of PD and NT. In addition, the algorithm was validated using various clinical cases to demonstrate its reliability. Therefore, this technique can be effectively utilized for clinical trials on stent-related side effects, including in-stent thrombosis and in-stent restenosis.« less

  10. Comparison of in-hospital and long-term outcomes between a Cypher stent and a Taxus stent in Chinese diabetic patients with coronary artery disease.

    PubMed

    Yang, Yue-jin; Xu, Bo; Kang, Sheng; Pei, Wei-dong; Chen, Ji-lin; Qiao, Shu-bin; Qin, Xue-wen; Yao, Min; Chen, Jue; Wu, Yong-jian; Liu, Hai-Bo; You, Shi-Jie; Li, Jian-Jun; Dai, Jun; Gao, Run-Lin

    2007-11-05

    The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conducted to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent (Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI) in Chinese patients with diabetes. One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63 patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at 6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC). The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI), target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P > 0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%, P = 0.524), re-MI (0 vs 2.0%, P = 0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P = 0.299) and very late thrombosis (0 vs 3.0%, P = 0.295) between 1-year and 3-year follow-up. The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in the small population of Chinese diabetic patients during long-term follow-up.

  11. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: 5 years follow-up from the randomized DEDICATION trial (Drug Elution and Distal Protection in Acute Myocardial Infarction).

    PubMed

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne; Thuesen, Leif; Lassen, Jens Flensted; Clemmensen, Peter; Kløvgaard, Lene; Engstrøm, Thomas; Bøtker, Hans E; Saunamäki, Kari; Krusell, Lars R; Jørgensen, Erik; Tilsted, Hans-Henrik; Christiansen, Evald H; Ravkilde, Jan; Køber, Lars; Kofoed, Klaus Fuglsang; Terkelsen, Christian J; Helqvist, Steffen

    2013-06-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) trial evaluated the outcome after DES compared with BMS implantation in patients with STEMI undergoing primary percutaneous coronary intervention. Patients with a high-grade stenosis/occlusion of a native coronary artery presenting with symptoms <12 h and ST-segment elevation were enrolled after giving informed consent. Patients were randomly assigned to receive a DES or a BMS in the infarct-related lesion. Patients were followed for at least 5 years, and clinical endpoints were evaluated from population registries and hospital charts. The main endpoint was the occurrence of the first major adverse cardiac event (MACE), defined as cardiac death, nonfatal recurrent myocardial infarction, and target lesion revascularization. Complete clinical status was available in 623 patients (99.5%) at 5 years follow-up. The combined MACE rate was insignificantly lower in the DES group (16.9% vs. 23%), mainly driven by a lower need of repeat revascularization (p = 0.07). Whereas the number of deaths from all causes tended to be higher in the DES group (16.3% vs. 12.1%, p = 0.17), cardiac mortality was significantly higher (7.7% vs. 3.2%, p = 0.02). The 5-year stent thrombosis rates were generally low and similar between the DES and the BMS groups. No cardiac deaths occurring within 1 month could be clearly ascribed to stent thrombosis, whereas stent thrombosis was involved in 78% of later-occurring deaths. The 5-year MACE rate was insignificantly different, but the cardiac mortality was higher after DES versus BMS implantation in patients with STEMI. Stent thrombosis was the main cause of late cardiac deaths. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Costs and Cost-Effectiveness of Carotid Stenting versus Endarterectomy for Patients at Standard Surgical Risk: Results from the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST)

    PubMed Central

    Vilain, Katherine R.; Magnuson, Elizabeth A.; Li, Haiyan; Clark, Wayne M.; Begg, Richard J.; Sam, Albert D.; Sternbergh, W. Charles; Weaver, Fred A.; Gray, William A.; Voeks, Jenifer H.; Brott, Thomas G.; Cohen, David J.

    2012-01-01

    Background The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) demonstrated similar rates of the primary composite endpoint between carotid artery stenting (CAS) and carotid endarterectomy (CEA), although the risk of stroke was higher with CAS, and the risk of myocardial infarction (MI) was higher with CEA. Given the large number of patients who are candidates for these procedures, an understanding of their relative cost and cost-effectiveness may have important implications for healthcare policy and treatment guidelines. Methods We performed a formal economic evaluation alongside the CREST trial. Costs were estimated from all trial participants over the first year of follow-up using a combination of resource use data and hospital billing data. Patient-level health utility scores were obtained using data from the SF-36. We then used a Markov disease-simulation model calibrated to the CREST results to project 10-year costs and quality-adjusted life expectancy for the 2 treatment groups. Results Although initial procedural costs were $1025/patient higher with CAS, post-procedure costs and physician costs were lower, such that total costs for the index hospitalization were similar for the CAS and CEA groups ($15,055 versus $14,816; mean difference $239/patient, 95% CI for difference, −$297 to $775). Neither follow-up costs after discharge nor total 1-year costs differed significantly. For the CREST population, model-based projections over a 10-year time horizon demonstrated that CAS would result in a mean incremental cost of $524/patient and a reduction in quality-adjusted life expectancy of 0.008 years compared with CEA. Probabilistic sensitivity analysis demonstrated that CEA was economically attractive at an incremental cost-effectiveness threshold of $50,000/quality-adjusted life-year gained in 54% of samples, whereas CAS was economically attractive in 46%. Conclusions Despite slightly lower in-trial costs and lower rates of stroke with CEA compared with CAS, projected 10-year outcomes from this controlled clinical trial demonstrate only trivial differences in overall healthcare costs and quality-adjusted life expectancy between the 2 strategies. If the CREST results can be replicated in clinical practice, these findings suggest that factors other than cost-effectiveness should be considered when deciding between treatment options for carotid artery stenosis in patients at standard risk for surgical complications. PMID:22821614

  13. Self-Expanding Versus Balloon-Expandable Stents for Iliac Artery Occlusive Disease: The Randomized ICE Trial.

    PubMed

    Krankenberg, Hans; Zeller, Thomas; Ingwersen, Maja; Schmalstieg, Josefin; Gissler, Hans Martin; Nikol, Sigrid; Baumgartner, Iris; Diehm, Nicolas; Nickling, Estell; Müller-Hülsbeck, Stefan; Schmiedel, Rainer; Torsello, Giovanni; Hochholzer, Willibald; Stelzner, Christian; Brechtel, Klaus; Ito, Wulf; Kickuth, Ralph; Blessing, Erwin; Thieme, Marcus; Nakonieczny, Jaroslaw; Nolte, Thomas; Gareis, Ragnar; Boden, Harald; Sixt, Sebastian

    2017-08-28

    Atherosclerosis of iliac arteries is widespread. As inflow vessels, they are of great clinical significance and increasingly being treated by endovascular means. Most commonly, stents are implanted. So far, due to a lack of comparative data, no guideline recommendations on the preferable stent type, balloon-expandable stent (BE) or self-expanding stent (SE), have been issued. In this randomized, multicenter study, patients with moderate to severe claudication from common or external iliac artery occlusive disease were assigned 1:1 to either BE or SE. The primary endpoint was binary restenosis at 12 months as determined by duplex ultrasound. Key secondary endpoints were walking impairment, freedom from target lesion revascularization (TLR), hemodynamic success, target limb amputation, and all-cause death. Six hundred sixty patients with 660 lesions were enrolled at 18 German and Swiss sites over a period of 34 months; 24.8% of the patients had diabetes and 57.4% were current smokers. The common iliac artery was affected in 58.9%. One hundred nine (16.5%) lesions were totally occluded and 25.6% heavily calcified. Twelve-month incidence of restenosis was 6.1% after SE implantation and 14.9% after BE implantation (p = 0.006). Kaplan-Meier estimate of freedom from TLR was 97.2% and 93.6%, respectively (p = 0.042). There was no between-group difference in walking impairment, hemodynamic success, amputation rate, all-cause death, or periprocedural complications. The treatment of iliac artery occlusive disease with SE as compared with BE resulted in a lower 12-month restenosis rate and a significantly reduced TLR rate. No safety concerns arose in both groups. (Iliac, Common and External [ICE] Artery Stent Trial; NCT01305174). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Long-term clinical follow-up of the multicentre, randomized study to test immunosuppressive therapy with oral prednisone for the prevention of restenosis after percutaneous coronary interventions: Cortisone plus BMS or DES veRsus BMS alone to EliminAte Restenosis (CEREA-DES).

    PubMed

    Ribichini, Flavio; Tomai, Fabrizio; Pesarini, Gabriele; Zivelonghi, Carlo; Rognoni, Andrea; De Luca, Giuseppe; Boccuzzi, Giacomo; Presbitero, Patrizia; Ferrero, Valeria; Ghini, Anna S; Marino, Paolo; Vassanelli, Corrado

    2013-06-01

    To analyse the clinical outcome at 4 years in patients with coronary artery disease treated with bare metal stents (BMS) vs. BMS and oral prednisone, or drug-eluting stents (DES), all assuming similar adjunctive medical treatment. Five Italian hospitals enrolled 375 non-diabetic, ischaemic patients without contraindications to dual anti-platelet treatment or corticosteroid therapy in a randomized controlled study. The primary endpoint was the event-free survival of cardiovascular death, myocardial infarction, and recurrence of ischaemia needing repeated target vessel revascularization at 1 year, and this was significantly lower in the BMS group (80.8%) compared with the prednisone (88.0%) and DES group (88.8%, P = 0.04 and 0.006, respectively). The long-term analysis of the primary endpoint was a pre-specified aim of the trial, and was performed at 1447 days (median, IQ range = 1210-1641). Patients receiving BMS alone had significantly lower event-free survival (75.3%) compared with 84.1% in the prednisone group (HR: 0.447; 95% CI: 0.25-0.80, P = 0.007) and 80.6% in DES patients (HR: 0.519; 95% CI: 0.29-0.93, P = 0.03). Prednisone-treated patients did not develop new treatment-related clinical problems. Drug-eluting stents patients suffered more very late stent thrombosis as a cause of spontaneous myocardial infarction. The need for target vessel revascularization remained lower in the prednisone and DES groups (13.6 and 15.2%, respectively), compared with BMS (23.2%). The clinical benefits of prednisone compared with BMS only persisted almost unchanged at 4 years. Drug-eluting stents performed better than BMS at long-term, although the advantages observed at 1 year were in part attenuated because of the occurrence of very late stent thrombosis and late revascularizations. Clinical Trial NCT 00369356.

  15. Analysis of simulated angiographic procedures. Part 2: extracting efficiency data from audio and video recordings.

    PubMed

    Duncan, James R; Kline, Benjamin; Glaiberman, Craig B

    2007-04-01

    To create and test methods of extracting efficiency data from recordings of simulated renal stent procedures. Task analysis was performed and used to design a standardized testing protocol. Five experienced angiographers then performed 16 renal stent simulations using the Simbionix AngioMentor angiographic simulator. Audio and video recordings of these simulations were captured from multiple vantage points. The recordings were synchronized and compiled. A series of efficiency metrics (procedure time, contrast volume, and tool use) were then extracted from the recordings. The intraobserver and interobserver variability of these individual metrics was also assessed. The metrics were converted to costs and aggregated to determine the fixed and variable costs of a procedure segment or the entire procedure. Task analysis and pilot testing led to a standardized testing protocol suitable for performance assessment. Task analysis also identified seven checkpoints that divided the renal stent simulations into six segments. Efficiency metrics for these different segments were extracted from the recordings and showed excellent intra- and interobserver correlations. Analysis of the individual and aggregated efficiency metrics demonstrated large differences between segments as well as between different angiographers. These differences persisted when efficiency was expressed as either total or variable costs. Task analysis facilitated both protocol development and data analysis. Efficiency metrics were readily extracted from recordings of simulated procedures. Aggregating the metrics and dividing the procedure into segments revealed potential insights that could be easily overlooked because the simulator currently does not attempt to aggregate the metrics and only provides data derived from the entire procedure. The data indicate that analysis of simulated angiographic procedures will be a powerful method of assessing performance in interventional radiology.

  16. Prospective Evaluation of Two iStent® Trabecular Stents, One iStent Supra® Suprachoroidal Stent, and Postoperative Prostaglandin in Refractory Glaucoma: 4-year Outcomes.

    PubMed

    Myers, Jonathan S; Masood, Imran; Hornbeak, Dana M; Belda, Jose I; Auffarth, Gerd; Jünemann, Anselm; Giamporcaro, Jane Ellen; Martinez-de-la-Casa, Jose M; Ahmed, Iqbal Ike K; Voskanyan, Lilit; Katz, L Jay

    2018-03-01

    This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1-3 glaucoma medications. Subjects received two iStent ® trabecular micro-bypass stents, one iStent Supra ® suprachoroidal stent, and postoperative travoprost. Postoperative IOP was measured with medication and annually following medication washouts. Performance was measured by the proportion of eyes with ≥ 20% IOP reduction on one medication (the protocol-specified prostaglandin) versus preoperative medicated IOP (primary outcome); and the proportion of eyes with postoperative IOP ≤ 15 and ≤ 18 mmHg on one medication (secondary outcome). Additional clinical and safety data included medications, visual field, pachymetry, gonioscopy, adverse events, visual acuity, and slit-lamp and fundus examinations. Preoperatively, mean medicated IOP was 22.0 ± 3.1 mmHg on 1.2 ± 0.4 medications, and mean unmedicated IOP was 26.4 ± 2.4 mmHg. Postoperatively, among eyes without later cataract surgery, mean medicated IOP at all visits through 48 months was ≤ 13.7 mmHg (≥ 37% reduction), and annual unmedicated IOP was ≤ 18.4 mmHg (reductions of ≥ 30% vs. preoperative unmedicated IOP and ≥ 16% vs. preoperative medicated IOP). At all postoperative visits among eyes without additional surgery or medication, ≥ 91% of eyes had ≥ 20% IOP reduction on one medication versus preoperative medicated IOP. At month 48, 97 and 98% of eyes achieved IOP ≤ 15 and ≤ 18 mmHg, respectively, on one medication. Six eyes required additional medication, no eyes required additional glaucoma surgery, and safety measurements were favorable throughout follow-up. IOP control was achieved safely with two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin. This microinvasive, ab interno approach introduces a possible new treatment option for refractory disease. NCT01456390. Glaukos Corporation.

  17. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    PubMed

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels <3 mm in diameter. We analyzed the impact of stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; P<.001). The benefit of a DES compared to a BMS regarding ISR was consistent among the subgroups of stent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels <3.0 mm and lesions >15 mm length. © 2016 John Wiley & Sons Ltd.

  18. The PARAGON stent study: a randomized trial of a new martensitic nitinol stent versus the Palmaz-Schatz stent for treatment of complex native coronary arterial lesions.

    PubMed

    Holmes, D R; Lansky, A; Kuntz, R; Bell, M R; Buchbinder, M; Fortuna, R; O'Shaughnessy, C D; Popma, J

    2000-11-15

    A new martensitic nitinol stent with improved flexibility and radiopacity was tested to evaluate whether these differences improve initial or long-term outcome. Patients who underwent percutaneous revascularization of a discrete native coronary lesion were randomly assigned to the new stent (PARAGON, n = 349) or to the first-generation Palmaz-Schatz (PS) stent (n = 339). The primary end point was target vessel failure at 6 months (a composite of cardiac or noncardiac death, any infarction in the distribution of the treated vessel, or clinically indicated target vessel revascularization). Secondary end points were, among others, device and procedural success and angiographic restenosis. Mean age was 62 years; diabetes was present in 21% of patients, prior bypass surgery in 6%, and recent infarction in 22% (p = NS for comparison between the 2 randomized arms). The PARAGON stent group had smaller reference vessels (2.97 vs 3.05 mm, p = 0.05), more prior restenosis (8.0% vs 4.5%, p = 0.07), and a longer average stent length (21.3 vs 19.4 mm, p < 0.05). Device success was significantly higher in the PARAGON arm (99.1% vs 94.3%, p < 0.05). Death and infarction at 6-month follow-up were infrequent in both groups. There was no significant difference in death (2.0% vs 1.2%, p = 0.546), but a higher rate of infarction for the PARAGON cohort (9.2% vs 4.7%, p = 0.025). Although target vessel failure (20.3% vs 12.4%, p = 0.005) and target lesion revascularization (12.0% vs 5.9%, p = 0.005) were higher in the PARAGON group, there was no significant difference in 6-month follow-up in in-stent minimal lumen diameter or in the rate of binary angiographic restenosis. Both PARAGON and PS stents are safe and associated with infrequent adverse events. The PARAGON stent can be delivered more frequently than the first-generation PS stent. Although there was no significant difference in in-stent minimal lumen diameter or the frequency of angiographic restenosis, clinical restenosis was more frequent in the PARAGON group.

  19. A new era of prospective real-world safety evaluation primary report of XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System condition-of-approval post-market study).

    PubMed

    Krucoff, Mitchell W; Rutledge, David R; Gruberg, Luis; Jonnavithula, Lalitha; Katopodis, John N; Lombardi, William; Mao, Vivian W; Sharma, Samin K; Simonton, Charles A; Tamboli, Hoshedar P; Wang, Jin; Wilburn, Olivia; Zhao, Weiying; Sudhir, Krishnankutty; Hermiller, James B

    2011-12-01

    The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System Condition-of-Approval Post-Market study) sought to: 1) evaluate the safety of everolimus-eluting coronary stent systems (EECSS) in a contemporary cohort of real-world subjects; and 2) prospectively test the quality of event reporting with analysis of matched patients from the randomized SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions) trial. Randomized trials have demonstrated the safety and efficacy of EECSS in selected "standard-risk" patients. The XIENCE V USA trial was a prospective, multicenter, single-arm study in unselected patients. The primary endpoint was Academic Research Consortium (ARC)-defined definite and probable stent thrombosis (ST); the co-primary endpoint was the composite of cardiac death and myocardial infarction at 1 year. Secondary analyses included: 1) stratification by standard-risk and extended-risk cohorts; and 2) late ST after dual antiplatelet therapy interruption. Of 5,054 participants (1,875 standard-risk; 3,179 extended-risk), 4,958 (98.1%) reached 1-year follow-up. The rate of ARC-defined definite and probable ST was 0.84% (95% confidence interval [CI]: 0.60% to 1.14%) in the overall population and 0.33% (95% CI: 0.12% to 10.72%) and 1.14% (95% CI: 0.80% to 11.58%) in the standard-risk and extended-risk cohorts, respectively. No late ST was observed after dual antiplatelet therapy interruption in either cohort after 6 months. The composite rate of cardiac death and ARC-defined myocardial infarction was 6.5% (95% CI: 5.79% to 17.17%) in the overall population, 3.8% (95% CI: 2.98% to 14.78%) in the standard-risk cohort, and 8.0% (95% CI: 7.09% to 19.02%) in the extended-risk cohort. This study comprehensively reports ST rates for EECSS in a contemporary real-world population. The absence of ST after dual antiplatelet therapy interruption beyond 6 months in standard-risk and high-risk patients is notable. Consistent safety outcomes between matched standard-risk cohorts from the XIENCE V USA study and the SPIRIT IV randomized trial suggest that this study affords a reliable benchmark for understanding the safety of EECSS in the context of real-world clinical practice. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Three-year results of the VIBRANT trial of VIABAHN endoprosthesis versus bare nitinol stent implantation for complex superficial femoral artery occlusive disease.

    PubMed

    Geraghty, Patrick J; Mewissen, Mark W; Jaff, Michael R; Ansel, Gary M

    2013-08-01

    The predominant mode of bare nitinol stent failure is diffuse in-stent restenosis, and failure rates correlate to the length and complexity of the treated lesion. Addition of an expanded polytetrafluoroethylene lining to a nitinol stent frame, as found in the VIABAHN endoprosthesis, mitigates the ingrowth of intimal hyperplasia. We compared the long-term outcomes of complex superficial femoral artery disease intervention using the VIABAHN endoprosthesis to those obtained with bare nitinol stent implantation. One hundred forty-eight patients with symptomatic complex superficial femoral artery disease (TransAtlantic Inter-Society Consensus I class C and D lesions, accompanied by intermittent claudication or ischemic rest pain) were randomized to endovascular intervention using either bare nitinol stent implantation (76 patients) or nonheparin-bonded VIABAHN endoprosthesis deployment (72 patients). Patency, limb hemodynamics, and quality of life were evaluated at 1, 6, 12, 24, and 36 months following intervention. The average treated lesion measured 18 ± 8 cm in length, and 58.8% of lesions displayed segmental or complete occlusion. At 3 years, primary patency rates (defined by peak systolic velocity ratio ≤ 2.0 and no target lesion revascularization) did not significantly differ between patients treated with the VIABAHN stent graft and those who received a bare nitinol stent (24.2% vs 25.9%; P = .392). Stent fractures were significantly more common in bare nitinol stents (50.0%) than in the VIABAHN endoprostheses (2.6%). Primary-assisted patency rates were higher in those receiving bare nitinol stents than the VIABAHN stent graft (88.8% vs 69.8%; P = .04), although secondary patency rates did not differ between bare nitinol stent and stent graft recipients (89.3% vs 79.5%; P = .304). There were no instances of procedure-related mortality or amputation. The hemodynamic improvement and quality measures improved equally in both groups. The long-term outcomes of complex superficial femoral artery disease intervention using the VIABAHN endograft and bare nitinol stents are similar. Although primary patency rates are low in both study arms, excellent primary-assisted and secondary patency rates were achieved, with sustained augmentation of limb perfusion and quality-of-life measures. Patency rates diminish most rapidly in the first year after device implantation. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  1. Percutaneous Intraductal Radiofrequency Ablation for Extrahepatic Distal Cholangiocarcinoma: A Method for Prolonging Stent Patency and Achieving Better Functional Status and Quality of Life

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Tian-tian, E-mail: matthewwu1979@hotmail.com; Li, Wei-min, E-mail: weimin-li-surgery@126.com; Li, Hu-cheng, E-mail: hucheng-li-surgery@126.com

    PurposeThe clinical efficacy of intraductal radiofrequency ablation (RFA) with Habib™ EndoHPB catheter, a newly developed intervention for malignant extrahepatic biliary obstruction, remains uncertain. The aim of this study was to investigate the clinical efficacy of intraductal RFA.MethodsData from 71 patients with extrahepatic distal cholangiocarcinoma were retrospectively analyzed. The study patients were divided into RFA and control groups. The RFA group had undergone percutaneous transhepatic intraductal RFA with a Habib™ EndoHPB catheter, followed by placement of covered or uncovered biliary self-expandable metallic stents (SEMs) whereas the control group had undergone percutaneous transhepatic covered or uncovered SEMs placement. Procedure-related complications, stent patency,more » patient survival, and postoperative serum bilirubin concentrations were compared between the two groups. The Functional Assessment of Cancer Therapy-Hepatobiliary (FACT-Hep) questionnaire was administered to evaluate functional status, improvement in clinical manifestations, and quality of life.ResultsThe RFA group had a longer median stent patency than the control group (p = 0.001 for uncovered SEMs placement). Higher functional well-being, hepatobiliary-specific cancer subscale, Trial Outcome Index, and total FACT-Hep scores were observed during post-procedure follow-up in the RFA group. However, median survival did not differ significantly between the two groups (p > 0.05).ConclusionsProlongation of stent patency and better functional status and quality of life, which are all important clinical endpoints, were observed in patients treated with intraductal RFA. Prospective randomized controlled clinical trials are necessary to further investigate the clinical efficacy and long-term benefits of intraductal RFA.« less

  2. Third generation drug eluting stent (DES) with biodegradable polymer in diabetic patients: 5 years follow-up.

    PubMed

    Wiemer, Marcus; Stoikovic, Sinisa; Samol, Alexander; Dimitriadis, Zisis; Ruiz-Nodar, Juan M; Birkemeyer, Ralf; Monsegu, Jacques; Finet, Gérard; Hildick-Smith, David; Tresukosol, Damras; Novo, Enrique Garcia; Koolen, Jacques J; Barbato, Emanuele; Danzi, Gian Battista

    2017-02-10

    To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years. After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients. In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM). Five years follow-up has been completed in this study. At 5 years, 89.3% of the patients were available for follow-up. The reported target lesion failure (TLF) rates at 5 years were 12.39% in DM group and 7.34% in non-DM group; (p < 0.0001). In the DM group, the TLF rate in patients with IDDM was significantly higher than in the non-IDDM subgroup (17.84 vs. 10.67%; p < 0.01). The rate of ST at 5 years was not different among diabetic versus non-diabetic patients or IDDM versus NIDDM. Only 10 (<0.4%) very late stent thrombotic events beyond 12 months occurred. The Nobori DES performed well in patients with DM. As expected patients with DM, particularly those with IDDM, had worse outcomes. However, the very low rate of very late stent thrombosis in IDDM patients might have significant clinical value in the treatment of these patients. Clinical trial registration ISRCTN81649913; http://www.controlled-trials.com/isrctn/search.html?srch=81649913&sort=3&dir=desc&max=10.

  3. The effect of completeness of revascularization on event-free survival at one year in the ARTS trial.

    PubMed

    van den Brand, Marcel J B M; Rensing, Benno J W M; Morel, Marie-angèle M; Foley, David P; de Valk, Vincent; Breeman, Arno; Suryapranata, Harry; Haalebos, Maximiliaan M P; Wijns, William; Wellens, Francis; Balcon, Rafael; Magee, Patrick; Ribeiro, Expedito; Buffolo, Enio; Unger, Felix; Serruys, Patrick W

    2002-02-20

    We sought to assess the relationship between completeness of revascularization and adverse events at one year in the ARTS (Arterial Revascularization Therapies Study) trial. There is uncertainty to what extent degree of completeness of revascularization, using up-to-date techniques, influences medium-term outcome. After consensus between surgeon and cardiologist regarding the potential for equivalence in the completeness of revascularization, 1,205 patients with multivessel disease were randomly assigned to either bypass surgery or stent implantation. All baseline and procedural angiograms and surgical case-record forms were centrally assessed for completeness of revascularization. Of 1,205 patients randomized, 1,172 underwent the assigned treatment. Complete data for review were available in 1,143 patients (97.5%). Complete revascularization was achieved in 84.1% of the surgically treated patients and 70.5% of the angioplasty patients (p < 0.001). After one year, the stented angioplasty patients with incomplete revascularization showed a significantly lower event-free survival than stented patients with complete revascularization (i.e., freedom from death, myocardial infarction, cerebrovascular accident and repeat revascularization) (69.4% vs. 76.6%; p < 0.05). This difference was due to a higher incidence of subsequent bypass procedures (10.0% vs. 2.0%; p < 0.05). Conversely, at one year, bypass surgery patients with incomplete revascularization showed only a marginally lower event-free survival rate than those with complete revascularization (87.8% vs. 89.9%). Complete revascularization was more frequently accomplished by bypass surgery than by stent implantation. One year after bypass, there was no significant difference in event-free survival between surgically treated patients with complete revascularization and those with incomplete revascularization, but patients randomized to stenting with incomplete revascularization had a greater need for subsequent bypass surgery.

  4. Stent thrombosis and restenosis: what have we learned and where are we going? The Andreas Grüntzig Lecture ESC 2014

    PubMed Central

    Byrne, Robert A.; Joner, Michael; Kastrati, Adnan

    2015-01-01

    Modern-day stenting procedures leverage advances in pharmacotherapy and device innovation. Patients treated with contemporary antiplatelet agents, peri-procedural antithrombin therapy and new-generation drug-eluting stents (DES) have excellent outcomes over the short to medium term. Indeed, coupled with the reducing costs of these devices in most countries there remain very few indications where patients should be denied treatment with standard-of-care DES therapy. The two major causes of stent failure are stent thrombosis (ST) and in-stent restenosis (ISR). The incidence of both has reduced considerably in recent years. Current clinical registries and randomized trials with broad inclusion criteria show rates of ST at or <1% after 1 year and ∼0.2–0.4% per year thereafter; rates of clinical ISR are 5% respectively. Angiographic surveillance studies in large cohorts show rates of angiographic ISR of ∼10% with new-generation DES. The advent of high-resolution intracoronary imaging has shown that in many cases of late stent failure neoatherosclerotic change within the stented segment represents a final common pathway for both thrombotic and restenotic events. In future, a better understanding of the pathogenesis of this process may translate into improved late outcomes. Moreover, the predominance of non-stent-related disease as a cause of subsequent myocardial infarction during follow-up highlights the importance of lifestyle and pharmacological interventions targeted at modification of the underlying disease process. Finally, although recent developments focus on strategies which circumvent the need for chronically indwelling stents—such as drug-coated balloons or fully bioresorbable stents—more data are needed before the wider use of these therapies can be advocated. PMID:26417060

  5. A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent: The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet).

    PubMed

    Schofer, Joachim; Musiałek, Piotr; Bijuklic, Klaudija; Kolvenbach, Ralf; Trystula, Mariusz; Siudak, Zbigniew; Sievert, Horst

    2015-08-17

    This study sought to evaluate the feasibility of the CGuard Carotid Embolic Protective Stent system-a novel thin strut nitinol stent combined with a polyethylene terephthalate mesh covering designed to prevent embolic events from the target lesion in the treatment of carotid artery lesions in consecutive patients suitable for carotid artery stenting. The risk of cerebral embolization persists throughout the carotid artery stenting procedure and remains during the stent healing period. A total of 30 consecutive patients (age 71.6 ± 7.6 years, 63% male) meeting the conventional carotid artery stenting inclusion criteria were enrolled in 4 centers in Germany and Poland. The primary combined endpoint was the procedure success of the CGuard system and the number and volume of new lesions on the ipsilateral side assessed by diffusion-weighted magnetic resonance imaging at 48 h post-procedure and at 30 days. The secondary endpoint was 30-day major adverse cardiac or cerebrovascular events (death, stroke, or myocardial infarction). Protection devices were used in all procedures. Procedure success was 100%, with 0% procedural complications. The 30-day major adverse cardiac or cerebrovascular events rate was 0%. New ipsilateral ischemic lesions at 48 h occurred in 37.0% of patients and the average lesion volume was 0.039 ± 0.08 cm(3). The 30-day diffusion-weighted magnetic resonance imaging showed complete resolution of all but 1 periprocedural lesion and only 1 new minor (0.116 cm(3)) lesion in relation to the 48-h scan. The use of the CGuard system in patients undergoing carotid artery stenting is feasible. In addition, the benefit of using CGuard may extend throughout the stent healing period. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Endoscopic ultrasound-guided placement of plastic vs. biflanged metal stents for therapy of walled-off necrosis: a retrospective single-center series.

    PubMed

    Mukai, Shuntaro; Itoi, Takao; Baron, Todd H; Sofuni, Atsushi; Itokawa, Fumihide; Kurihara, Toshio; Tsuchiya, Takayoshi; Ishii, Kentaro; Tsuji, Shujiro; Ikeuchi, Nobuhito; Tanaka, Reina; Umeda, Junko; Tonozuka, Ryosuke; Honjo, Mitsuyoshi; Gotoda, Takuji; Moriyasu, Fuminori; Yasuda, Ichiro

    2015-01-01

    Recently, a novel fully covered and biflanged metal stent (BFMS)dedicated to the drainage of walled-off necrosis(WON) was developed. The aim of this study was to retrospectively evaluate the safety, efficacy, and cost performance of drainage of WON using the novel BFMS compared with a traditional plastic stent. A total of 70 patients with symptomatic WON were treated under endoscopic ultrasound (EUS) guidance. Initial drainage was conducted using the single gateway technique with placement of one or more plastic stents or a single BFMS.If drainage was unsuccessful,direct endoscopic necrosectomy (DEN)was performed. There were no statistically significant differences in rates of technical success, clinical success,and adverse events between plastics stents and BFMS, despite the size of WON in the BFMS group being significantly larger than that in the plastic stent group (105.6 vs. 77.1 mm; P=0.003).The mean procedure times for the first EUS-guided drainage and for re-intervention were significantly shorter in the BFMS group than in the plastic stent group (28.8±7.1 vs. 42.6±14.2, respectively,for drainage, P<0.001; and 34.9±8.5 vs.41.8±7.6, respectively, for re-intervention, P<0.001). There was no statistically significant difference in the total cost between plastic stent and BFMS use in the treatment of WON ($5352vs. $6274; P=0.25). Plastic stents and BFMS were safe and effective for the treatment of WON. In particular,BFMS placement appeared to be preferable for initial EUS-guided drainage and additional reintervention(e.g. DEN) as it reduced the procedure time. Prospective randomized controlled trials are warranted.

  7. In-hospital management and outcome of patients on warfarin undergoing coronary stent implantation: results of the multicenter, prospective WARfarin and coronary STENTing (WAR-STENT) registry.

    PubMed

    Rubboli, Andrea; Sciahbasi, Alessandro; Briguori, Carlo; Saia, Francesco; Palmieri, Cataldo; Moroni, Luigi Andrea; Calabrò, Paolo; Leone, Antonio Maria; Franco, Nicoletta; Valgimigli, Marco; Varani, Elisabetta; Santi, Michela; Pasqualini, Paola; Capecchi, Alessandro; Piccalò, Giacomo; Margheri, Massimo; di Pasquale, Giuseppe; Galvani, Marcello; Bolognese, Leonardo; Gonzini, Lucio; Maggioni, Aldo Pietro

    2013-04-01

    The in-hospital management of patients on warfarin undergoing coronary stent implantation (PCI-S) is variable, and the in-hospital outcome incompletely defined. To determine the adherence to the current recommendations, and the incidence of adverse events, we carried out the prospective, multicenter, observational WARfarin and coronary STENTing (WAR-STENT) registry (ClinicalTrials.gov identifier NCT00722319). All consecutive patients on warfarin undergoing PCI-S at 37 Italian centers were enrolled and followed for 12 months. Outcome measures were: major adverse cardiovascular events (MACE), including cardiovascular death, non-fatal myocardial infarction, need for urgent revascularization, stroke, and venous thromboembolism, and major and minor bleeding. In this paper, we report the in-hospital findings. Out of the 411 patients enrolled, 92% were at non-low (ie, moderate or high) thromboembolic risk. The radial approach and bare-metal stents were used in 61% and 60% of cases, respectively. Drug-eluting stents were essentially reserved to patients with diabetes, which in turn, significantly predicted the implantation of drug-eluting stents (odds ratio [OR], 2.02; 95% confidence interval [CI], 1.29-3.17; P=.002). The in-hospital MACE and major bleeding rates were 2.7% and 2.1%, respectively. At discharge, triple therapy (TT) of warfarin, aspirin, and clopidogrel was prescribed to 76% of patients. Prescription of TT was significantly more frequent in the non-low thromboembolic risk group. Non-low thromboembolic risk, in turn, was a significant predictor of TT prescription (OR, 11.2; 95% CI, 4.83-26.3; P<.0001). In conclusion, real-world warfarin patients undergoing PCI-S are largely managed according to the current recommendations. As a consequence, the risk of in-hospital MACE and major bleedings appears limited and acceptable.

  8. Usage patterns and 1-year outcomes with the TAXUS Liberté stent: results of the TAXUS OLYMPIA registry.

    PubMed

    Ahmed, Waqar H; Mendiz, Oscar A; Thomas, Martyn R

    2011-06-01

    The TAXUS OLYMPIA registry is a prospective, global, post-approval program designed to collect clinical outcome data through 1 year from patients receiving the TAXUS Liberté paclitaxel-eluting stent in routine interventional cardiology practice. The thin-strut TAXUS Liberté stent has been studied in ongoing clinical trials with specific inclusion/exclusion criteria. Between September 2005 and April 2007, a total of 21,954 patients from 365 sites in 57 countries eligible to receive a TAXUS Liberté stent were enrolled in the TAXUS OLYMPIA registry. Baseline characteristics and procedure patterns were collected and clinical follow-up is available for 1 year. The primary endpoint was the composite cardiac event (cardiac death, MI, and reintervention of the target vessel) rate related to the TAXUS Liberté stent at 1 year. All cardiac events were monitored and all endpoints were independently adjudicated. Complex patients and lesions were prevalent, including: 27% medically-treated diabetes, 58% ACC/AHA type B2/C lesions, 32% multiple stenting, 13% long lesions (>28 mm), and 10% small vessels (<2.5 mm). At 1 year, the composite cardiac event rate was 4.4%, including 1.4% cardiac death, 1.0% MI, and 3.2% TVR. Stent thrombosis (ST, angiographically confirmed) occurred in 0.8% of patients, with 0.4% ST occurring >30 days postprocedure. The composite cardiac event rate related to the TAXUS Liberté stent was 3.8% at 1 year. Low 1-year cardiac event rates were reported with TAXUS Liberté in a broad spectrum of patients, thereby confirming the technical and clinical performance of this stent in a "real-world" setting. Copyright © 2010 Wiley-Liss, Inc.

  9. Durability of the balloon-expandable covered versus bare-metal stents in the Covered versus Balloon Expandable Stent Trial (COBEST) for the treatment of aortoiliac occlusive disease.

    PubMed

    Mwipatayi, Bibombe P; Sharma, Surabhi; Daneshmand, Ali; Thomas, Shannon D; Vijayan, Vikram; Altaf, Nishath; Garbowski, Marek; Jackson, Mark

    2016-07-01

    The Covered vs Balloon Expandable Stent Trial (COBEST) is the first multicenter trial to investigate the patency of covered stents (CSs) and bare-metal stents (BMSs) in the treatment of aortoiliac arterial disease. The short-term results demonstrated that CSs were superior to BMSs in maintaining patency for TransAtlantic Inter-Society Consensus (TASC) C and D lesions at 18 months and were equivalent to BMSs for TASC B lesions. The current study was conducted to determine if the initial patency advantage of CSs over BMSs was sustained at the 5-year follow-up. A retrospective post hoc analysis of COBEST was performed. Originally, 125 patients with 168 iliac arteries were prospectively enrolled and randomly assigned to receive a CS or BMS. In this study, 77 of the 125 patients (61.6%; 119 limbs) were assessed at 60 months for the primary and secondary end points, with particular attention paid to the outcomes stratified according to TASC lesion severity. The primary end point was the rate of binary stenosis or freedom from stent occlusion of the treated area, as determined by ultrasound imaging or quantitative visual angiography. The 5-year results of the COBEST showed that the CS had a significantly higher patency rate than the BMS at 18, 24, 48, and 60 months (95.1%, 82.1%, 79.9%, 74.7% for CS vs 73.9%, 70.9%, 63% and 62.5% for BMS; log-rank test, P = .01). On multivariate analysis, the type of stent used (hazard ratio [HR], 2.797; 95% confidence interval [CI], 1.471-5.318; P = .002) and the Rutherford classification (HR, 2.019; 95% CI, 1.278-3.191; P = .026) significantly affected the adjusted primary patency. On subgroup analysis, the CS showed significantly higher patency and a survival benefit compared with the BMS in TASC C and D lesions (HR, 8.639; 95% CI, 54.253-75.753; P = .003). Moreover, fewer patients received target limb revascularization in the CS group than in the BMS group (odds ratio, 2.32; 95% CI, 1.47-3.36; P = .02); however, there was no statistically significant difference in the rate of amputations between the groups. The 5-year results of the COBEST demonstrated that the CS has an enduring patency advantage over the BMS in both the short and long terms. Furthermore, the CS showed acceptable patency rates for the treatment of more severe TASC C and D lesions, and patients who received a CS required fewer revascularization procedures. However, the choice of stent did not affect the rate of major limb amputations. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. The NICE recommendation for drug-coated balloons and its global impact.

    PubMed

    Eccleshall, Simon; Waliszewski, M

    2015-06-01

    The clinical efficacy and safety of drug-coated balloon (DCB) angioplasty in patients with coronary in-stent restenosis (ISR) has been demonstrated. The objective of this article is to provide comparative cost efficacy data for DCB angioplasty in various countries based on the original methodology of the Medical Technologies Evaluation Programme (MTEP) at the National Institute for Health and Clinical Excellence (NICE) in 2010. Published and unpublished Health Technology Assessment (HTA) reports were evaluated for comparison in selected countries. Furthermore, a systematic review of economic evaluations of DCB angioplasty versus standard treatments (uncoated balloon angioplasty or drug-eluting stent implantations) was conducted. National cost efficacy data were evaluated using Markov state transition models which were adapted to fit each country's device and procedure related costs. The clinical input for adverse events was defined with two relevant trials for in-stent restenosis of bare metal stents (BMS-ISR) and of drug-eluting stents (DES-ISR). In the UK, Germany, Switzerland, South Africa, Japan and Brazil, DCB angioplasty is cost-effective when compared with drug-eluting stents to treat either BMS-ISR or DES-ISR. DCB angioplasty ought to be the preferred treatment option for patients with BMS-ISR and DES-ISR from the payers' point of view. © The Author(s), 2015.

  11. A break-even price calculation for the use of sirolimus-eluting stents in angioplasty.

    PubMed

    Galanaud, Jean-Philippe; Delavennat, Juliette; Durand-Zaleski, Isabelle

    2003-03-01

    One of the major complications of angioplasty is the early occurrence of restenosis requiring a repeat procedure. When bare-metal stents are used, clinical restenosis results in a repeat procedure in 10% to 15% of cases. Based on the results of an international, randomized clinical trial, the use of sirolimus-eluting stents reduces this risk. The aims of this study were to calculate the theoretical break-even price for sirolimus-eluting stents in France, the Netherlands, and the United States, and to determine the additional health care cost per patient. The break-even price was calculated by adding the savings resulting from a 15% decrease in the rate of clinical restenosis to the price of bare-metal stents. Costs were computed from the viewpoint of the health care system, exclusive of other societal costs. The break-even prices were 1291 Euro to 1489 Euro in France, 2028 Euro in the Netherlands, and 2708 Euroin the United States (1.00 Euro = 1.00 US dollar in purchasing power parity). These results indicate that the commercial price of sirolimuseluting stents will increase hospital spending for patients undergoing angioplasty by 17% to 55% per patient. This additional cost to the health care system should be discussed in view of possible productivity savings and improved quality of life for patients.

  12. Cost-efficacy in interventional cardiology; results from the EPISTENT study. Evaluation of Platelet IIb/IIIa Inhibitor For Stenting Trial.

    PubMed

    Zwart-van Rijkom, J E; van Hout, B A

    2001-08-01

    The EPISTENT study has demonstrated that the combined use of abciximab and stenting as an adjunct to PTCA leads to increased event-free survival compared to either using abciximab or stenting alone. However, this combined strategy may be costly and the additional costs have to be weighted against the additional effects. The 6-months efficacy data from the EPISTENT study are combined with Dutch estimates of unit costs. Adding a stent to a procedure with abciximab further decreases the number of revascularizations at an extra cost of Euros 12,000 (95% upper limit (u.l.) Euros 31,000) per additional major adverse cardiac event-free survivor. Adding abciximab to a stenting procedure decreases the incidence of myocardial infarctions at an extra cost of Euros 13,000 (95% u.l. Euros 27,000) per additional myocardial infarction-free survivor. In the subgroup of diabetics, adding abciximab improves revascularization rates as well, resulting in a cost-efficacy rate of Euros 2000 (95% u.l. Euros 25,000) per additional MACE-free survivor, with uncertainty regions indicating potential costs savings. The combination of stenting and abciximab costs about Euros 13,000 to avoid one event after PTCA. In diabetic patients the strategy may be cost-saving. Copyright 2001 The European Society of Cardiology.

  13. [Mechanical thrombectomy in acute ischemic stroke. What is the position after the latest study results?].

    PubMed

    Hacke, W; Diener, H-C

    2015-06-01

    Mechanical devices for the recanalization of vessel occlusions in severe acute ischemic stroke have been developed for more than a decade. Several devices have been approved for clinical use on the basis of uncontrolled case series. Many neurologists have asked for randomized clinical trials comparing the new devices with standard treatment, e.g. thrombolytic therapy within a 4.5 h time window. The first 3 investigator initiated randomized trials published in 2013 failed to show superiority of mechanical thrombectomy over standard treatment. In the aftermath of these negative results several new trials with changes in design (e.g. shorter time window and only proximal vessel occlusions) and the use of modern devices with proven higher recanalization rates, so called stent retrievers, have been launched. In October 2014 the first of these new trials was presented and showed a clear superiority of thrombectomy. Based on this result interim analyses of five other studies were performed and most were prematurely terminated because of overwhelming efficacy. Only one trial testing another type of recanalization device failed to reach a statistically significant result. Currently five studies have already been published and two more studies have been presented at scientific conferences. This article provides an overview of the study protocols and the results of the individual studies, their common features and the characteristics of patients who benefit from this treatment. Finally, the consequences that these results may have for the treatment of patients with severe stroke caused by proximal vessel occlusion are discussed.

  14. Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction: A randomized controlled trial.

    PubMed

    Yang, Min Jae; Kim, Jin Hong; Yoo, Byung Moo; Hwang, Jae Chul; Yoo, Jun Hwan; Lee, Ki Seong; Kang, Joon Koo; Kim, Soon Sun; Lim, Sun Gyo; Shin, Sung Jae; Cheong, Jae Youn; Lee, Kee Myung; Lee, Kwang Jae; Cho, Sung Won

    2015-01-01

    Covered self-expandable metal stents (SEMSs) are increasingly used as alternatives to uncovered SEMSs for the palliation of inoperable malignant distal biliary obstruction to counteract tumor ingrowth. We aimed to compare the outcomes of partially covered and uncovered SEMSs with identical mesh structures and anti-migration properties, such as low axial force and flared ends. One hundred and three patients who were diagnosed with inoperable malignant distal biliary obstruction between January 2006 and August 2013 were randomly assigned to either the partially covered (n = 51) or uncovered (n = 52) SEMS group. There were no significant differences in the cumulative stent patency, overall patient survival, stent dysfunction-free survival and overall adverse events, including pancreatitis and cholecystitis, between the two groups. Compared to the uncovered group, stent migration (5.9% vs. 0%, p = 0.118) and tumor overgrowth (7.8% vs. 1.9%, p = 0.205) were non-significantly more frequent in the partially covered group, whereas tumor ingrowth showed a significantly higher incidence in the uncovered group (5.9% vs. 19.2%, p = 0.041). Stent migration in the partially covered group occurred only in patients with short stenosis of the utmost distal bile duct (two in ampullary cancer, one in bile duct cancer), and did not occur in any patients with pancreatic cancer. For the palliation of malignant distal biliary obstruction, endoscopic placement of partially covered SEMSs with anti-migration designs and identical mesh structures to uncovered SEMSs failed to prolong cumulative stent patency or reduce stent migration.

  15. Is pre-shock wave lithotripsy stenting necessary for ureteral stones with moderate or severe hydronephrosis?

    PubMed

    El-Assmy, Ahmed; El-Nahas, Ahmed R; Sheir, Khaled Z

    2006-11-01

    We performed a prospective, randomized clinical trial to evaluate the outcome of ureteral stents for solitary ureteral stones 2 cm or less in moderately or severely obstructed systems using shock wave lithotripsy. Between 2001 and 2004, 186 patients who met study criteria were randomized into 2 groups. Group 1 received a pre-shock wave lithotripsy 6Fr Double-J stent and group 2 had no stent. Patients were treated with a Dornier MFL 5000 lithotripter. Results were compared in terms of clearance rates, number of shock waves and sessions, irritative voiding symptoms, incidence of complications and secondary interventions. Failure was defined as the need for additional procedure(s) for stone extraction. Overall 164 patients (88.2%) became stone-free after shock wave lithotripsy. Complete stone fragmentation was achieved after 1 to 3 and more than 3 session in 108 (58.1%), 30 (16.1%), 13 (7%) and 14 patients (7.5%), respectively. Ureteral stent insertion did not affect the stone-free rate, which was 84.9% and 91.4% in groups 1 and 2, respectively (p = 0.25). There was no statistical difference in the re-treatment rate, flank pain or temperature in the 2 groups. However, all patients in the stented group significantly complained of side effects attributable to the stent, including dysuria, suprapubic pain, hematuria, pyuria and positive urinary culture. Pretreatment stenting provides no advantage over in situ shock wave lithotripsy for significantly obstructing ureteral calculi. Shock wave lithotripsy is reasonable initial therapy for ureteral stones 2 cm or less that cause moderate or severe hydronephrosis.

  16. Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing Study.

    PubMed

    Chiastra, Claudio; Grundeken, Maik J; Collet, Carlos; Wu, Wei; Wykrzykowska, Joanna J; Pennati, Giancarlo; Dubini, Gabriele; Migliavacca, Francesco

    2018-05-17

    The treatment of coronary bifurcations is challenging for interventional cardiologists. The Tryton stent (Tryton Medical, Inc., USA) is one of the few devices specifically designed for coronary bifurcations that underwent large clinical trials. Although the manufacturer provides specific recommendations to position the stent in the bifurcation side branch (SB) according to four radio-opaque markers under angiographic guidance, wrong device positioning may accidentally occur. In this study, the virtual bench testing approach was used to investigate the impact of wrong positioning of the Tryton stent in coronary bifurcations in terms of geometrical and biomechanical criteria. A finite element model of the left anterior descending/first diagonal coronary bifurcation was created with a 45° distal angle and realistic lumen diameters. A validated model of the Tryton stent mounted on stepped delivery balloon was used. All steps of the Tryton deployment sequence were simulated. Three Tryton positions, namely 'proximal', 'recommended', and 'distal' positions, obtained by progressively implanting the stent more distally in the SB, were compared. The 'recommended' case exhibited the lowest ostial area stenosis (44.8 vs. 74.3% ('proximal') and 51.5% ('distal')), the highest diameter at the SB ostium (2.81 vs. 2.70 mm ('proximal') and 2.54 mm ('distal')), low stent malapposition (9.9 vs. 16.3% ('proximal') and 8.5% ('distal')), and the lowest peak wall stress (0.37 vs. 2.20 MPa ('proximal') and 0.71 MPa ('distal')). In conclusion, the study shows that a 'recommended' Tryton stent positioning may be required for optimal clinical results.

  17. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruffino, Maria Antonella, E-mail: mruffino@cittadellasalute.to.it; Faletti, Riccardo; Bergamasco, Laura

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateralmore » ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.« less

  18. Influence of Preoperative Risk Factors on Outcome After Carotid Endarterectomy

    PubMed Central

    Sternbergh, W. Charles; Money, Samuel R.

    2003-01-01

    As supported by level 1 multicenter randomized trial data, carotid endarterectomy (CEA) has a very low risk of perioperative morbidity and excellent durability, and provides significant long-term reductions of the risk of stroke. At Ochsner, our 1.1% risk of major stroke or death after CEA (n=366) is a demonstration of the safety of this procedure in experienced hands. This treatment modality continues to be the gold standard for most patients with carotid artery occlusive disease. Almost half of these patients treated with CEA were considered “high-risk” as defined by ineligibility for past or present randomized carotid trials. Importantly, these “high-risk” patients had outcomes that were not statistically different from “low-risk” trial-eligible patients. Thus, evidence-based decision-making does not support the routine use of investigational carotid stenting in “high-risk” trial-ineligible patients. However, carotid stenting is clearly a valuable alternative for selected patients. Our challenge is to precisely define which patients will most benefit from medical, surgical, or catheter-based therapy for carotid artery occlusive disease. PMID:22470252

  19. Review and publication of protocol submissions to Trials - what have we learned in 10 years?

    PubMed

    Li, Tianjing; Boutron, Isabelle; Al-Shahi Salman, Rustam; Cobo, Erik; Flemyng, Ella; Grimshaw, Jeremy M; Altman, Douglas G

    2016-12-16

    Trials has 10 years of experience in providing open access publication of protocols for randomised controlled trials. In this editorial, the senior editors and editors-in-chief of Trials discuss editorial issues regarding managing trial protocol submissions, including the content and format of the protocol, timing of submission, approaches to tracking protocol amendments, and the purpose of peer reviewing a protocol submission. With the clarification and guidance provided, we hope we can make the process of publishing trial protocols more efficient and useful to trial investigators and readers.

  20. Preoperative biliary drainage by plastic or self-expandable metal stents in patients with periampullary tumors: results of a randomized clinical study

    PubMed Central

    Olsson, Greger; Frozanpor, Farshad; Lundell, Lars; Enochsson, Lars; Ansorge, Christoph; Del Chiaro, Marco; Reuterwall-Hansson, Marcus; Shetye, Alysha; Arnelo, Urban

    2017-01-01

    Background and study aims  Preoperative biliary drainage in patients with periampullary tumors and jaundice has been popularized to improve the quality of life and minimize the risks associated with subsequent radical surgery. The aim of this study was to investigate the possible superiority of self-expandable metal stents (SEMS) over plastic stents, by comparing the amount of bacteria in intraoperatively collected bile and using this variable as a proxy for the efficacy of the respective biliary drainage modalities. Patients and methods  In this randomized clinical trial, 92 patients with obstructive jaundice were enrolled; 45 were allocated to the plastic stent group and 47 to the SEMS group. The primary outcome was the extent and magnitude of biliary bacterial growth at the time of surgical exploration. Secondary outcomes were: macroscopic grading of inflammation of the stented bile ducts, occurrence of adverse events after stenting, stent dysfunction, recognized surgical complexities, and incidence of postoperative complications. Results  The patients were well matched regarding clinical and disease-specific characteristics. At surgery, there were no group differences in the bacterial amount and composition of the bile cultures or the perceived difficulty of surgical dissection. During the preoperative biliary drainage period, more instances of stent dysfunction requiring stent replacement were recorded in the plastic stent group (19 % vs. 0 %; P  = 0.03). Postoperative complications in patients who underwent curative surgery were more common in patients with plastic stents (72 % vs. 52 %), among which clinically significant leakage from the pancreatic anastomoses seemed to predominate (12 % vs. 3.7 %); however, none of these differences in postoperative adverse events reached statistical significance. Conclusion  This randomized clinical study was unable to demonstrate any superiority of SEMS in the efficacy of preoperative bile drainage, as assessed by the amount of bacteria in the intraoperatively collected bile. However, some data in favor of SEMS were observed among the clinical secondary outcomes variables (preoperative stent exchange rates) without increases in local inflammatory reactions. PMID:28879225

  1. SPIRIT 2013 Statement: defining standard protocol items for clinical trials.

    PubMed

    Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krle A-Jerić, Karmela; Hrobjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Dore, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David

    2015-12-01

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.

  2. SPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials

    PubMed Central

    Chan, An-Wen; Tetzlaff, Jennifer M.; Altman, Douglas G.; Laupacis, Andreas; Gøtzsche, Peter C.; Krleža-Jerić, Karmela; Hróbjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A.; Doré, Caroline J.; Parulekar, Wendy R.; Summerskill, William S.M.; Groves, Trish; Schulz, Kenneth F.; Sox, Harold C.; Rockhold, Frank W.; Rennie, Drummond; Moher, David

    2016-01-01

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders. PMID:23295957

  3. SPIRIT 2013 statement: defining standard protocol items for clinical trials.

    PubMed

    Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krleža-Jerić, Karmela; Hróbjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Doré, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David

    2013-02-05

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol.The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.

  4. Long-term Outcome of Short Metallic Stents for Lobar Airway Stenosis.

    PubMed

    Fruchter, Oren; Abed El Raouf, Bayya; Rosengarten, Dror; Kramer, Mordechai R

    2017-07-01

    Whereas stents are considered an excellent treatment for proximal central major airway stenosis, the value of stenting for distal lobar airway stenosis is still controversial. Our aim was to explore the short-term and long-term outcome of metallic stents placed for benign and malignant lobar airway stenosis. Between July 2007 and July 2014, 14 patients underwent small airway stent insertion. The clinical follow-up included serial semiannual physical examinations, pulmonary function tests, imaging, and bronchoscopy. The etiologies for airway stenosis were: early post-lung transplantation bronchial stenosis (N=5), sarcoidosis (N=1), amyloidosis (N=1), anthracofibrosis (N=1), right middle lobe syndrome due to external lymph node compression (N=1), lung cancer (N=4), and stenosis of the left upper lobe of unknown etiology (N=1). Stents were placed in the right upper lobe bronchus (N=2), right middle lobe bronchus (N=6), left upper lobe bronchus (N=4), linguar bronchus (N=1), and left lower lobe bronchus (N=1). The median follow-up period ranged from 2 to 72 months (median 18 mo). Immediate relief of symptoms was achieved in the vast majority of patients (13/14, 92%). Out of 10 patients with benign etiology for stenosis, 9 (90%) experienced sustained and progressive improvement in pulmonary function tests and clinical condition. We describe our positive experience with small stents for lobar airway stenosis; further prospective trials are required to evaluate the value of this novel modality of treatment.

  5. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    PubMed

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length < 1 cm: 21 Cristallo Ideale (Invatec, Roncadelle, Italy); straight vessel, lesion length > 1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  6. Results of a randomized clinical trial of external beam radiation to prevent restenosis after superficial femoral artery stenting.

    PubMed

    Therasse, Eric; Donath, David; Elkouri, Stéphane; Lespérance, Jacques; Giroux, Marie-France; Oliva, Vincent L; Guertin, Marie-Claude; Bouchard, Louis; Perreault, Pierre; Gilbert, Patrick; Soulez, Gilles

    2016-06-01

    The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Circulating endothelial progenitor cells are inversely correlated with in-stent restenosis in patients with non-ST-segment elevation acute coronary syndromes treated with EPC-capture stents (JACK-EPC trial).

    PubMed

    Wojakowski, W; Pyrlik, A; Król, M; Buszman, P; Ochała, A; Milewski, K; Smolka, G; Kawecki, D; Rudnik, A; Pawłowski, T; Jadczyk, T; Wyderka, R; Cybulski, W; Dworowy, S; Tendera, M

    2013-06-01

    Aim of the study was to evaluate the association between circulating endothelial progenitor cells (EPCs) and angiographic outcomes after implantation of GenousTM stent in patients with non-ST-segment elevation acute coronary syndromes (ACS) (NSTE-ACS) undergoing urgent percutaneous coronary intervention (PCI). Sixty patients treated with EPC-capture stent (N.=30) or bare metal stents (BMS) (N.=30) receiving 80 mg atorvastatin and dual antiplatelet therapy (DAT) for 12 months. Restenosis was assessed after 6 months by quantitative coronary angiography (QCA) and major acute coronary events (MACE) evaluated after 6 and 12 months. de novo lesion >70% in native vessel, diameter 2.5-4 mm, lesion length <30 mm. diabetes, previous revascularization, significant left main stenosis, chronic total occlusions (CTO) and multivessel disease. Majority of patients in EPC-capture stent and BMS groups presented with NSTEMI (73.3% and 70%, respectively). Mean stent length was 20.1±8 and 19.9±10 mm, diameter 3±0.97 and 3.1±0.88 mm in respective groups. The binary restenosis was significantly lower in GenousTM (13 vs. 26.6%, P=0.04). Risk of MACE after 6 and 12 months were comparable in both groups. There was no stent thrombosis. Numbers of circulating EPCs were significantly approximately 2-fold higher during the ACS than after 6 months. Mobilization of EPCs during acute ischemia was significantly lower in patients who developed restenosis after 6 months (3 vs. 4.5 cells/μL, P=0.002) and it was negatively correlated with late-loss after 6 months (R=-0.42; P<0.03). Use of GenousTM stents in NSTE-ACS is associated with lower restenosis rate than BMS at 6 months. There was no ST through 1 year. The number of circulating EPCs is inversely correlated with in-stent late loss (LL).

  8. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients—Can This Concept Work Out? A Single Center Experience Focusing on Stent Design

    PubMed Central

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-01-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length < 1 cm: 21 Cristallo Ideale (Invatec, Roncadelle, Italy); straight vessel, lesion length > 1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58–87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1–59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up. PMID:25484558

  9. Video networking of cardiac catheterization laboratories.

    PubMed

    Tobis, J; Aharonian, V; Mansukhani, P; Kasaoka, S; Jhandyala, R; Son, R; Browning, R; Youngblood, L; Thompson, M

    1999-02-01

    The purpose of this study was to assess the feasibility and accuracy of a video telecommunication network to transmit coronary images to provide on-line interaction between personnel in a cardiac catheterization laboratory and a remote core laboratory. A telecommunication system was installed in the cardiac catheterization laboratory at Kaiser Hospital, Los Angeles, and the core laboratory at the University of California, Irvine, approximately 40 miles away. Cineangiograms, live fluoroscopy, intravascular ultrasound studies and images of the catheterization laboratory were transmitted in real time over a dedicated T1 line at 768 kilobytes/second at 15 frames/second. These cases were performed during a clinical study of angiographic guidance versus intravascular ultrasound (IVUS) guidance of stent deployment. During the cases the core laboratory performed quantitative analysis of the angiograms and ultrasound images. Selected images were then annotated and transmitted back to the catheterization laboratory to facilitate discussion during the procedure. A successful communication hookup was obtained in 39 (98%) of 40 cases. Measurements of angiographic parameters were very close between the original cinefilm and the transmitted images. Quantitative analysis of the ultrasound images showed no significant difference in any of the diameter or cross-sectional area measurements between the original ultrasound tape and the transmitted images. The telecommunication link during the interventional procedures had a significant impact in 23 (58%) of 40 cases affecting the area to be treated, the size of the inflation balloon, recognition of stent underdeployment, or the existence of disease in other areas that was not noted on the original studies. Current video telecommunication systems provide high-quality images on-line with accurate representation of cineangiograms and intravascular ultrasound images. This system had a significant impact on 58% of the cases in this small clinical trial. Telecommunication networks between hospitals and a central core laboratory may facilitate physician training and improve technical skills and judgement during interventional procedures. This project has implications for how multicenter clinical trials could be operated through telecommunication networks to ensure conformity with the protocol.

  10. Drug‐coated balloons for de novo lesions in small coronary arteries: rationale and design of BASKET‐SMALL 2

    PubMed Central

    Gilgen, Nicole; Farah, Ahmed; Scheller, Bruno; Ohlow, Marc‐Alexander; Mangner, Norman; Weilenmann, Daniel; Wöhrle, Jochen; Jamshidi, Peiman; Leibundgut, Gregor; Möbius‐Winkler, Sven; Zweiker, Robert; Krackhardt, Florian; Butter, Christian; Bruch, Leonhard; Kaiser, Christoph; Hoffmann, Andreas; Rickenbacher, Peter; Mueller, Christian; Stephan, Frank‐Peter; Coslovsky, Michael

    2018-01-01

    The treatment of coronary small vessel disease (SVD) remains an unresolved issue. Drug‐eluting stents (DES) have limited efficacy due to increased rates of instent‐restenosis, mainly caused by late lumen loss. Drug‐coated balloons (DCB) are a promising technique because native vessels remain structurally unchanged. Basel Stent Kosten‐Effektivitäts Trial: Drug‐Coated Balloons vs. Drug‐Eluting Stents in Small Vessel Interventions (BASKET‐SMALL 2) is a multicenter, randomized, controlled, noninferiority trial of DCB vs DES in native SVD for clinical endpoints. Seven hundred fifty‐eight patients with de novo lesions in vessels <3 mm in diameter and an indication for percutaneous coronary intervention such as stable angina pectoris, silent ischemia, or acute coronary syndromes are randomized 1:1 to angioplasty with DCB vs implantation of a DES after successful initial balloon angioplasty. The primary endpoint is the combination of cardiac death, nonfatal myocardial infarction, and target‐vessel revascularization up to 1 year. Secondary endpoints include stent thrombosis, Bleeding Academic Research Consortium (BARC) type 3 to 5 bleeding, and long‐term outcome up to 3 years. Based on clinical endpoints after 1 year, we plan to assess the noninferiority of DCB compared to DES in patients undergoing primary percutaneous coronary intervention for SVD. Results will be available in the second half of 2018. This study will compare DCB and DES regarding long‐term safety and efficacy for the treatment of SVD in a large all‐comer population. PMID:29527709

  11. Comparing Mobile Health Strategies to Improve Medication Adherence for Veterans With Coronary Heart Disease (Mobile4Meds): Protocol for a Mixed-Methods Study.

    PubMed

    Park, Linda G; Collins, Eileen G; Shim, Janet K; Whooley, Mary A

    2017-07-18

    Adherence to antiplatelet medications is critical to prevent life threatening complications (ie, stent thrombosis) after percutaneous coronary interventions (PCIs), yet rates of nonadherence range from 21-57% by 12 months. Mobile interventions delivered via text messaging or mobile apps represent a practical and inexpensive strategy to promote behavior change and enhance medication adherence. The Mobile4Meds study seeks to determine whether text messaging or a mobile app, compared with an educational website control provided to all Veterans, can improve adherence to antiplatelet therapy among patients following acute coronary syndrome (ACS) or PCI. The three aims of the study are to: (1) determine preferences for content and frequency of text messaging to promote medication adherence through focus groups; (2) identify the most patient-centered app that promotes adherence, through a content analysis of all commercially available apps for medication adherence and focus groups centered on usability; and (3) compare adherence to antiplatelet medications in Veterans after ACS/PCI via a randomized clinical trial (RCT). We will utilize a mixed-methods design that uses focus groups to achieve the first and second aims (N=32). Patients will be followed for 12 months after being randomly assigned to one of three arms: (1) customized text messaging, (2) mobile app, or (3) website-control groups (N=225). Medication adherence will be measured with electronic monitoring devices, pharmacy records, and self-reports. Enrollment for the focus groups is currently in progress. We expect to enroll patients for the RCT in the beginning of 2018. Determining the efficacy of mobile technology using a Veteran-designed protocol to promote medication adherence will have a significant impact on Veteran health and public health, particularly for individuals with chronic diseases that require strict medication adherence. ClinicalTrials.gov NCT03022669. ©Linda G Park, Eileen G Collins, Janet K Shim, Mary A Whooley. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 18.07.2017.

  12. Minimally invasive glaucoma surgery as primary stand-alone surgery for glaucoma.

    PubMed

    Kerr, Nathan M; Wang, Jing; Barton, Keith

    2017-05-01

    Recently, many new devices and procedures have been developed to lower intraocular pressure in a less invasive and purportedly safer manner than traditional glaucoma surgery. These new devices might encourage an earlier transition to surgery and reduce the long-term commitment to topical glaucoma medications with their associated compliance and intolerance issues. Although often seen as an adjunct to cataract surgery, a growing body of evidence suggests that primary minimally invasive glaucoma surgery may be a viable initial treatment option. New studies have shown that primary ab interno trabeculectomy (Trabectome, NeoMedix Inc., Tustin, CA, USA), trabecular micro-bypass stent insertion (iStent and iStent Inject, Glaukos Corporation, Laguna Hills, CA, USA), canalicular scaffolding (Hydrus, Invantis Inc., Irvine CA, USA), the ab interno gel Implant (XEN, Allergan, Dublin, Ireland) or supraciliary stenting (CyPass Micro-Stent, Alcon, Fort Worth, TX, USA) may lower the lowering intraocular pressure and/or topical medication burden in phakic or pseudophakic patients with glaucoma. This effect seems to last at least 12 months but reliable cost-effectiveness and quality of life indicators have not yet been established by investigator-initiated randomized trials of sufficient size and duration. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  13. [Effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation].

    PubMed

    Ge, Qihang; Wan, Chunyou; Liu, Yabei; Ji, Xu; Ma, Jihai; Cao, Haikun; Yong, Wei; Liu, Zhao; Zhang, Ningning

    2017-08-01

    To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation. The data of 45 cases with tibial and fibular open fractures treated by Taylor space stent fixation who meet the selection criteria between January 2015 and June 2016 were retrospectively analysed. The patients were divided into trial group (23 cases) and control group (22 cases) according to whether the axial stress stimulation was performed after operation. There was no significant difference in gender, age, affected side, cause of injury, type of fracture, and interval time from injury to operation between 2 groups ( P >0.05). The axial stress stimulation was performed in trial group after operation. The axial load sharing ratio was tested, and when the value was less than 10%, the external fixator was removed. The fracture healing time, full weight-bearing time, and external fixator removal time were recorded and compared. After 6 months of external fixator removal, the function of the limb was assessed by Johner-Wruhs criteria for evaluation of final effectiveness of treatment of tibial shaft fractures. There were 2 and 3 cases of needle foreign body reaction in trial group and control group, respectively, and healed after symptomatic anti allergic treatment. All the patients were followed up 8-12 months with an average of 10 months. All the fractures reached clinical healing, no complication such as delayed union, nonunion, or osteomyelitis occurred. The fracture healing time, full weight-bearing time, and external fixator removal time in trial group were significantly shorter than those in control group ( P <0.05). After 6 months of external fixator removal, the function of the limb was excellent in 13 cases, good in 6 cases, fair in 3 cases, and poor in 1 case in trial group, with an excellent and good rate of 82.6%; and was excellent in 5 cases, good in 10 cases, fair in 4 cases, and poor in 3 cases in control group, with an excellent and good rate of 68.2%, showing significant difference between 2 groups ( Z =-2.146, P =0.032). The axial stress stimulation of Taylor space stent fixation can promote the healing of tibial and fibular open fractures and promote local bone formation at fracture site.

  14. Long-term outcomes in patients with rheumatologic disorders undergoing percutaneous coronary intervention: a BAsel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination (BASKET-PROVE) sub-study.

    PubMed

    Nochioka, Kotaro; Biering-Sørensen, Tor; Hansen, Kim Wadt; Sørensen, Rikke; Pedersen, Sune; Jørgensen, Peter Godsk; Iversen, Allan; Shimokawa, Hiroaki; Jeger, Raban; Kaiser, Christoph; Pfisterer, Matthias; Galatius, Søren

    2017-12-01

    Rheumatologic disorders are characterised by inflammation and an increased risk of coronary artery disease (CAD). However, the association between rheumatologic disorders and long-term prognosis in CAD patients undergoing percutaneous coronary intervention (PCI) is unknown. Thus, we aimed to examine the association between rheumatologic disorders and long-term prognosis in CAD patients undergoing PCI. A post-hoc analysis was performed in 4605 patients (age: 63.3 ± 11.0 years; male: 76.6%) with ST-segment elevation myocardial infarction (STEMI; n = 1396), non-STEMI ( n = 1541), and stable CAD ( n = 1668) from the all-comer stent trials, the BAsel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination (BASKET-PROVE) I and II trials. We evaluated the association between rheumatologic disorders and 2-year major adverse cardiac events (MACEs; cardiac death, nonfatal myocardial infarction (MI), and target vessel revascularisation (TVR)) by Cox regression analysis. Patients with rheumatologic disorders ( n = 197) were older, more often female, had a higher prevalence of renal disease, multi-vessel coronary disease, and bifurcation lesions, and had longer total stent lengths. During the 2-year follow-up, the MACE rate was 8.6% in the total cohort. After adjustment for potential confounders, rheumatologic disorders were associated with MACEs in the total cohort (adjusted hazard ratio: 1.55; 95% confidence interval (CI): 1.04-2.31) driven by the STEMI subgroup (adjusted hazard ratio: 2.38; 95% CI: 1.26-4.51). In all patients, rheumatologic disorders were associated with all-cause death (adjusted hazard ratio: 2.05; 95% CI: 1.14-3.70), cardiac death (adjusted hazard ratio: 2.63; 95% CI: 1.27-5.43), and non-fatal MI (adjusted hazard ratio: 2.64; 95% CI: 1.36-5.13), but not with TVR (adjusted hazard ratio: 0.81; 95% CI: 0.41-1.58). The presence of rheumatologic disorders appears to be independently associated with worse outcome in CAD patients undergoing PCI. This calls for further studies and focus on this high-risk group of patients following PCI.

  15. Medical therapy is best for atherosclerotic renal artery stenosis: Arguments for.

    PubMed

    Annigeri, R A

    2012-01-01

    Atherosclerotic renal artery stenosis (ARAS) is a common condition that causes hypertension and reduction in the glomerular filtration rate and is an independent risk factor for death. Despite high technical success, the clinical benefit of renal artery (RA) angioplasty with stenting in ARAS remains doubtful. The published randomized clinical trials provide no support for the notion that renal angioplasty with stenting significantly improves blood pressure, preserves renal function, or reduces episodes of congestive heart failure in patients with ARAS. RA stenting is associated with procedure-related morbidity and mortality. Agents to block the renin-angiotensin-aldosterone system improve outcome and should be a part of a multifaceted medical regimen in ARAS. Medical therapy effectively controls atherosclerotic renovascular disease at all levels of vasculature and hence is the best therapy for ARAS.

  16. Overview of evidence on emergency carotid stenting in patients with acute ischemic stroke due to tandem occlusions: a systematic review and meta-analysis.

    PubMed

    Coelho, Andreia; Lobo, Miguel; Gouveia, Ricardo; Silveira, Diogo; Campos, Jacinta; Augusto, Rita; Coelho, Nuno; Canedo, Alexandra

    2018-01-23

    Endovascular intracranial thrombectomy (IT) has established itself as the standard of care in treating large-vessel anterior circulation acute ischemic stroke (AIS). However, internal carotid artery (ICA) stenosis/occlusion hampers distal access and controversy about simultaneous emergency ICA stenting ensues. The purpose of this review was to evaluate the safety of emergency ICA stenting in combination with IT for AIS with tandem occlusions. To our knowledge this is the first meta-analysis to evaluate emergency ICA stenting in tandem occlusions, combining results from studies with a control group. A systematic review and meta-analysis was conducted according to the recommendations of the Preferred Reporting Items for Systematic reviews and Meta- Analyses (PRISMA) statement. A total of 649 potentially relevant articles were initially selected. After reviewing at title or abstract level, 87 articles were read in full and 23 were included. These studies recruited 1000 patients, 220 submitted to IT with no emergency ICA stenting and 780 to IT and emergency ICA stenting. Successful revascularization (Thrombolysis in cerebral infarction scale - TICI≥2b) was achieved in 48.6-100%. Good outcome (modified Rankin scale - mRS≤2) ranged from 18.2-100%. Symptomatic intracranial haemorrhage (sICH) ranged from 0-45.7% (overall n=168; 17.2%). Mortality at 90 days ranged from 0-45.4% (overall n=114; 11.7%). Time to recanalization was significantly longer in the stenting group with an overall mean difference of 1.76 (95% Confidence Interval: 1.59-1.93). In this meta-analysis time to recanalization was significantly longer in the emergency ICA stenting group. There was no benefit from emergency stenting in parameters such as successful revascularization (TICI≥2b), clinical outcome (mRS≤2) or 90-day mortality. Data on sICH were scarce. Emergency ICA stenting appears to increase time to revascularization and increase the risk of complications with no demonstrated clinical benefit. Furthermore, no prospective, randomized controlled trials demonstrating relative efficacy and safety of concomitant ICA stenting have been published to date. Additional studies must be undertaken to define the role of angioplasty and stenting of the extracranial carotid arteries in the early management of acute stroke in tandem occlusions. Until then, we recommend that ICA stenting concommintant to thrombectomy in acute stroke patients should be avoided.

  17. Economic modeling of new stent platforms to evaluate cost effectiveness: analysis of the TAXUS Liberté versus TAXUS express stents.

    PubMed

    Turco, Mark A; Kansal, Anuraag R; Stern, Sean; Amorosi, Stacey L; Underwood, Paul L; Lissovoy, Greg D E; Dawkins, Keith D

    2012-08-01

    With the changing health care environment, cost effectiveness is an important adjunct to clinical investigation when assessing new medical devices. This study presents an economic model to evaluate cost effectiveness of coronary stents. Markov modeling was developed comparing total costs (Medicare payer perspective) between TAXUS Liberté and TAXUS Express based on 3-year clinical outcomes from the TAXUS ATLAS Small Vessel and Long Lesion trials. The TAXUS Liberté 2.25-mm stent provided cost savings relative to TAXUS Express from a payer perspective ($17,605 vs. $20,281), driven by reduced target vessel revascularization (0.16 events/patient vs. 0.33 events/patient). In probabilistic sensitivity analyses, TAXUS Liberté was less costly with fewer major adverse cardiac events in over 99% of parameter sets. The TAXUS Liberté Long (38 mm) stent was cost neutral relative to TAXUS Express from a payer perspective ($18,545 vs. $18,551) with fewer myocardial infarctions and cardiac deaths. Accounting for angiography-driven revascularizations, TAXUS Liberté 2.25 mm still provided cost savings relative to TAXUS Express ($16,822 vs. $19,139), although TAXUS Liberté Long was more expensive than TAXUS Express ($17,886 vs. $17,652). From a hospital perspective, TAXUS Liberté Long provided cost savings up to a price premium of $671/stent, driven by fewer stents employed per patient. This analysis confirms the utility of economic modeling in assessing new stent platforms. TAXUS Liberté 2.25 mm is economically dominant relative to TAXUS Express when treating small vessels. TAXUS Liberté Long is cost neutral to modestly more costly than TAXUS Express 2.25 mm from a payer perspective. ©2012, Wiley Periodicals, Inc.

  18. Biological effect of microengineered grooved stents on strut healing: a randomised OCT-based comparative study in humans

    PubMed Central

    Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F

    2017-01-01

    Objective To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. Background In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). Methods A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. Results At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75–95.52) compared with the MSG group (74.21%, 58.85–86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. Conclusions MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. Classifications BMS, OCT, clinical trials. PMID:28674616

  19. Biological effect of microengineered grooved stents on strut healing: a randomised OCT-based comparative study in humans.

    PubMed

    Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F

    2017-01-01

    To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75-95.52) compared with the MSG group (74.21%, 58.85-86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. BMS, OCT, clinical trials.

  20. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    PubMed

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  1. When is carotid angioplasty and stenting the cost-effective alternative for revascularization of symptomatic carotid stenosis? A Canadian health system perspective.

    PubMed

    Almekhlafi, M A; Hill, M D; Wiebe, S; Goyal, M; Yavin, D; Wong, J H; Clement, F M

    2014-02-01

    Carotid revascularization procedures can be complicated by stroke. Additional disability adds to the already high costs of the procedure. To weigh the cost and benefit, we estimated the cost-utility of carotid angioplasty and stenting compared with carotid endarterectomy among patients with symptomatic carotid stenosis, with special emphasis on scenario analyses that would yield carotid angioplasty and stenting as the cost-effective alternative relative to carotid endarterectomy. A cost-utility analysis from the perspective of the health system payer was performed by using a Markov analytic model. Clinical estimates were based on a meta-analysis. The procedural costs were derived from a microcosting data base. The costs for hospitalization and rehabilitation of patients with stroke were based on a Canadian multicenter study. Utilities were based on a randomized controlled trial. In the base case analysis, carotid angioplasty and stenting were more expensive (incremental cost of $6107) and had a lower utility (-0.12 quality-adjusted life years) than carotid endarterectomy. The results are sensitive to changes in the risk of clinical events and the relative risk of death and stroke. Carotid angioplasty and stenting were more economically attractive among high-risk surgical patients. For carotid angioplasty and stenting to become the preferred option, their costs would need to fall from more than $7300 to $4350 or less and the risks of the periprocedural and annual minor strokes would have to be equivalent to that of carotid endarterectomy. In the base case analysis, carotid angioplasty and stenting were associated with higher costs and lower utility compared with carotid endarterectomy for patients with symptomatic carotid stenosis. Carotid angioplasty and stenting were cost-effective for patients with high surgical risk.

  2. Comparison of Immediate With Delayed Stenting Using the Minimalist Immediate Mechanical Intervention Approach in Acute ST-Segment-Elevation Myocardial Infarction: The MIMI Study.

    PubMed

    Belle, Loic; Motreff, Pascal; Mangin, Lionel; Rangé, Grégoire; Marcaggi, Xavier; Marie, Antoine; Ferrier, Nadine; Dubreuil, Olivier; Zemour, Gilles; Souteyrand, Géraud; Caussin, Christophe; Amabile, Nicolas; Isaaz, Karl; Dauphin, Raphael; Koning, René; Robin, Christophe; Faurie, Benjamin; Bonello, Laurent; Champin, Stanislas; Delhaye, Cédric; Cuilleret, François; Mewton, Nathan; Genty, Céline; Viallon, Magalie; Bosson, Jean Luc; Croisille, Pierre

    2016-03-01

    Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24-48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention. In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment-elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29-46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4-6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P=0.051), which became significant after adjustment for the area at risk (P=0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment-elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01360242. © 2016 American Heart Association, Inc.

  3. Placement of a covered polyester stent prevents complications from a colorectal anastomotic leak and supports healing: randomized controlled trial in a large animal model.

    PubMed

    Tsereteli, Zurab; Sporn, Emanuel; Geiger, Timothy M; Cleveland, Dava; Frazier, Shellaine; Rawlings, Arthur; Bachman, Sharon L; Miedema, Brent W; Thaler, Klaus

    2008-11-01

    Anastomotic leaks after colorectal operation continue to be a significant cause of morbidity. A covered endoluminal stent could seal a leak and eliminate the need for diversion. The aim of this study was to test the efficacy of a temporary covered stent to prevent leak related complications. Sixteen adult pigs (80-120 lbs) underwent open transection of the rectosigmoid followed by anastomosis with a circular stapler. Eight animals (study group) underwent endoscopic placement of a 21-mm covered polyester stent. Eight control group animals were left without stents. In all animals, a 2-cm leak was created along the anterior portion of the anastomosis. The animals were killed after 2 weeks and evaluated for abdominal infection, fistulae, and adhesions. The anastomosis was excised and the following parameters were assessed by a pathologist blinded to treatment: mucosal interruption (mm), inflammatory response, collagen type I and III, granulation, and fibrosis (grade 0-4). Stents were spontaneously expelled between postoperative days 6 and 9. At necropsy, none of the animals in the study group had leak related complications, whereas in the control group, 5 (63%) developed intraabdominal infection (4 abscesses, 1 fistula) at the anastomosis (P = .002). Dense adhesions to the anastomosis were found in 7 (88%) control animals. On histology, anastomotic sites in the study group had significantly less mucosal interruption and granulation. Two pigs in the study group died on postoperative day 7, one due to evisceration and one from bladder necrosis. The mortality result is not different from controls (P = .47), both events seem to be unrelated to stent placement. Temporary placement of a covered polyester stent across a colorectal anastomosis prevents leak-related complications and supports the healing of anastomotic leaks.

  4. Radioactive self-expanding stents for palliative management of unresectable esophageal cancer: a systematic review and meta-analysis.

    PubMed

    Chen, Hong-Lin; Shen, Wang-Qin; Liu, Kun

    2017-05-01

    Stent insertion is a feasible and safe palliative management for advanced unresectable esophageal cancer. The aim of this study is to assess the efficacy of radioactive stent for unresectable esophageal cancer compared with conventional stent. Systematic searches of the PubMed and Web of science are dated from their beginning to January 25, 2016. Studies that compared radioactive stent with conventional stent for unresectable esophageal cancer were included. The outcomes were postimplantation survival, relief of dysphagia, and complications related to stent implant. Six studies with 539 patients were included. All of them used stent equipped with radioactive iodine beads as a radioactive stent. The pooled weighted mean difference for median survival was 2.734 months (95% CI 1.710-3.775; Z = 5.21, P = 0.000) between two groups. The 1,3,6 month survival rates were higher in radioactive stents than conventional stent, with the pooled ORs 3.216 (95% CI 1.293-7.999; Z = 2.51, P = 0.012), 3.095 (95% CI 1.908-5.020; Z = 4.58, P = 0.000), and 7.503 (95% CI 2.206- 25.516; Z = 3.23, P = 0.001, respectively). The pooled hazard ratio was 0.464 (95% CI 0.328-0.655; Z = 4.35, P = 0.000) between two groups. For relief of dysphagia, two stents all have good relief of the dysphagia effect, but radioactive stent showed a better effect at 3, 6 months follow-up after implantation. For complications related to stent implant, no significant differences were found between two stents in terms of severe chest pain (30.0% vs. 35.7%, OR 0.765, 95% CI 0.490-1.196), gastroesophageal reflux (18.6% vs. 16.1%, OR 1.188, 95% CI 0.453-3.115), fever (12.1% vs. 12.1%, OR 1.014, 95% CI 0.332-3.097), bleeding (16.7% vs. 14.2%, OR 1.201, 95% CI 0.645-2.236), perforation or fistula (6.1% vs. 9.0%, OR 0.658, 95% CI 0.291-1.486), pneumonia (10.7% vs. 14.1%, OR 0.724, 95% CI 0.343-1.526), stent migration (7.0% vs. 10.2%, OR 0.651, 95% CI 0.220-1.924), and restenosis (24.2% vs. 20.6%, OR 1.228, 95% CI 0.674-2.239). Radioactive stent insertion had potential benefits for palliative management for patients with unresectable esophageal cancer. This method prolonged survival and dysphagia relief period without more complications. However, this conclusion should be confirmed by more trials. © International Society for Diseases of the Esophagus 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Novel temperature-controlled RFA probe for treatment of blocked metal biliary stents in patients with pancreaticobiliary cancers: initial experience.

    PubMed

    Nayar, Manu K; Oppong, Kofi W; Bekkali, Noor L H; Leeds, John S

    2018-05-01

     Radiofrequency ablation (RFA) is used to treat blocked biliary stents in patients with pancreaticobiliary (PB) tumors with varying results. We report our experience with a novel temperature-controlled probe for treatment of blocked metal stents.  Patients with histologically proven PB cancers and a blocked biliary stents were treated using ELRATM electrode (Taewoong Medical) under fluoroscopic guidance. Demographics, clinical outcome, stricture diameter improvements, complications and mortality at 30 days were prospectively recorded.  Nine procedures were performed on seven patients (4 male, 3 female); mean age 65.33 (range 56 - 82 years). Mean stricture diameter prior to RFA was 1.13 mm (SD ± 0.54) and 4.42 mm (SD ± 1.54) following RFA ( P  < 0.0001). Five of seven patients (71 %) required additional stents to ensure optimal drainage. There were no procedure-related complications. Mean follow-up was 193.55 days (range 31 - 540) and three of nine patients (33 %) died due to terminal cancer. These are the first reported data on use of a temperature-controlled RFA catheter in humans to treat blocked metal biliary stents. The device is safe but further randomized trials are required to establish the efficacy and survival benefits of this probe.

  6. Management of acute cholangitis as a result of occlusion from a self-expandable metallic stent in patients with malignant distal and hilar biliary obstructions.

    PubMed

    Shiomi, Hideyuki; Matsumoto, Kazuya; Isayama, Hiroyuki

    2017-04-01

    Acute cholangitis as a result of common bile duct stones can be managed; however, cholangitis caused by occlusion with a biliary self-expandable metallic stent (SEMS) in patients with an unresectable malignant biliary obstruction has not been fully discussed. The acute cholangitis clinical guidelines (Tokyo Guidelines 2013) recommend following the same procedure as that used for cholangitis; however, the patient's condition, including performance status, tumor extension or staging, and prognosis must be considered. Most physicians manage cholangitis from a SEMS occlusion using a two-step procedure. They insert endoscopic drainage with a plastic stent or insert a nasobiliary drainage tube, which does not exacerbate sepsis. Addition or replacement of a biliary SEMS is required in many cases depending on the cause of the occlusion. Tumor ingrowth through the stent mesh is common in uncovered SEMS and requires placement of another stent in an in-stent method. However, covered SEMS tends to be occluded by sludge, so it must be replaced because of the bacterial biofilm that forms on the covering membrane. The location of the biliary stricture (hilar or distal) should also be considered. Strategies for managing cholangitis as a result of occlusion by a biliary SEMS remain controversial, so prospective clinical trials are needed. © 2017 The Authors. Digestive Endoscopy © 2017 Japan Gastroenterological Endoscopy Society.

  7. Bicanalicular Silicone Stents in Endonasal Dacryocystorhinostomy: Results of a Randomized Clinical Trial.

    PubMed

    Fayers, Tessa; Dolman, Peter J

    2016-10-01

    To assess whether the use of silicone lacrimal stents affects the long-term success of endonasal dacryocystorhinostomy (EN-DCR). Prospective, randomized, controlled, interventional trial. The subjects were adult patients older than 16 years undergoing primary EN-DCR for nasolacrimal duct obstruction who gave fully informed consent and who had no lid malpositions or canalicular pathology. In cases with bilateral surgery, only the right eyes were studied. Participants were randomized to receive stents (control group) or not (study group). Standardized nonendoscopic EN-DCR was performed by the senior author in all cases. When the ostium was completed, the randomization code was revealed as to whether a lacrimal stent was placed or not. Follow-up assessments were made at 3, 6, 9, and 12 months. Stents were removed at 3 months. The primary end point was symptoms of epiphora at 12 months, reported to the surgical booking clerk as (a) resolved, (b) significantly improved, (c) partially improved, or (d) no change or worse. The secondary end point was anatomic patency based on nasolacrimal syringing and categorized as (a) fully patent, minimal, or no reflux; (b) >50% patent but some reflux; (c) some patency but >50% reflux; or (d) nonpatent, 100% reflux. Complete success was defined as having resolved or significantly improved symptoms of watering and minimal or no reflux on nasolacrimal syringing. Partial success was defined as symptoms partially improved with a combination of patency and reflux on syringing. Failure was categorized as no change or worse symptoms of watering and 50% to 100% reflux on syringing. A total of 300 patients completed 12 months of follow-up. A total of 152 patients received tubes, and 148 patients did not. Overall success both subjectively and objectively was 94.7% in the stented group and 87.8% in the nonstented group (P = 0.034, Pearson chi-square 1-tailed test). The most common complications of stents included canalicular cheese-wiring and tube prolapse in approximately 4% each. There is a statistically significantly higher success rate in EN-DCR surgery with tubes compared with no tubes. The failure rate in this study was more than twice as high when tubes were not used (12.2% vs. 5.3%). Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. New stent design for use in small coronary arteries during percutaneous coronary intervention

    PubMed Central

    Granada, Juan F; Huibregtse, Barbara A; Dawkins, Keith D

    2010-01-01

    Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel), and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches), intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001), instent binary restenosis (13.0% versus 38.1%, P < 0.001), and target lesion revascularization (5.8% versus 17.6%, P < 0.001) at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03) and instent binary restenosis (13.0% versus 25.9%, P = 0.02) when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS Liberté Atom compared with the TAXUS Express Atom at nine months (5.8% versus 13.7%, P = 0.02) was sustained through three years (10.0% versus 22.1%, P = 0.008) with similar, stable safety outcomes between the groups. In conclusion, these data confirm the safety and favorable performance of the TAXUS Liberté Atom stent in the treatment of small coronary vessels. PMID:22915922

  9. A comparative study of short- and medium-term outcomes comparing emergent surgery and stenting as a bridge to surgery in patients with acute malignant colonic obstruction.

    PubMed

    Kavanagh, Dara O; Nolan, Blathnaid; Judge, Ciaran; Hyland, John M P; Mulcahy, Hugh E; O'Connell, P Ronan; Winter, Des C; Doherty, Glen A

    2013-04-01

    The use of self-expanding metal stents as a bridge to surgery in the setting of malignant colorectal obstruction has been advocated as an acceptable alternative to emergency surgery. However, concerns about the safety of stenting have been raised following recent randomized studies. The aim of the current study was to compare outcomes. This was an observational, comparative study. This study was conducted at a tertiary referral center and university teaching hospital. Patients with malignant colonic obstruction (n = 49) treated by either emergency surgery (n = 26) or with stent placement (n = 23) as a bridge to surgery were identified and followed. Short-term outcomes including stoma rates and postoperative morbidity and medium-term oncological outcomes were compared based on an "intention-to-treat" analysis. Patients in both groups were well matched on clinicopathological parameters. Technical and clinical successful stent deployment was achieved in 91% and 83%. This did not adversely impact cancer-specific and overall survival (log rank = nonsignificant). No difference was observed in stoma rates, primary anastomosis rates, perioperative mortality rates, or reoperation rates between the 2 groups. Significantly fewer patients underwent total colectomy in the stent group in comparison with the emergency surgery group (1/23 vs 6/26: p = 0.027). There was no difference in postoperative morbidity (59% vs 66%: p = 0.09). There was a significant reduction in readmission rates in the stent group (5/26 vs 0/23: p = 0.038). The small sample size of this study could lead to type II error. In addition, the study was nonrandomized and demonstrated a limited length of follow-up. Despite a high rate of technical and clinical success in selected patients with colonic obstruction, stenting has no impact on stoma rates. Despite concerns about the rate of stent-associated perforation, stenting does not adversely impact disease progression or survival. Future comparative trials are essential to better define the role of stenting in this setting and to ensure that we are not using costly technology to create an elective operative situation without concomitant patient benefits.

  10. Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).

    PubMed

    Lee, Joo Myung; Park, Kyung Woo; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon-Kwon; Bae, Jang-Whan; Woo, Sung-Il; Park, Jin Sik; Jin, Dong-Kyu; Jeon, Dong Woon; Oh, Seok Kyu; Park, Jong-Seon; Kim, Doo-Il; Hyon, Min Su; Jeon, Hui-Kyung; Lim, Do-Sun; Kim, Myeong-Gon; Rha, Seung-Woon; Her, Sung-Ho; Hwang, Jin-Yong; Kim, Sanghyun; Choi, Young Jin; Kang, Jin Ho; Moon, Keon-Woong; Jang, Yangsoo; Kim, Hyo-Soo

    2014-11-01

    Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p <0.001) and off-label indication (adjusted HR 1.782, 95% CI 1.169 to 2.718, p = 0.007) were the strongest predictors of target lesion failure at 3 years. In conclusion, both stents showed comparable safety and efficacy at 3-year follow-up in this robust real-world registry with unrestricted use of EES and ZES-R. Overall incidences of target lesion failure and definite stent thrombosis, including very late stent thrombosis, were low, even in the patients with off-label indications, suggesting excellent long-term safety and sustained efficacy of both types of second-generation drug-eluting stents. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Comparison between publicly accessible publications, registries, and protocols of phase III trials indicated persistence of selective outcome reporting.

    PubMed

    Zhang, Sheng; Liang, Fei; Li, Wenfeng

    2017-11-01

    The decision to make protocols of phase III randomized controlled trials (RCTs) publicly accessible by leading journals was a landmark event in clinical trial reporting. Here, we compared primary outcomes defined in protocols with those in publications describing the trials and in trial registration. We identified phase III RCTs published between January 1, 2012, and June 30, 2015, in The New England Journal of Medicine, The Lancet, The Journal of the American Medical Association, and The BMJ with available protocols. Consistency in primary outcomes between protocols and registries (articles) was evaluated. We identified 299 phase III RCTs with available protocols in this analysis. Out of them, 25 trials (8.4%) had some discrepancy for primary outcomes between publications and protocols. Types of discrepancies included protocol-defined primary outcome reported as nonprimary outcome in publication (11 trials, 3.7%), protocol-defined primary outcome omitted in publication (10 trials, 3.3%), new primary outcome introduced in publication (8 trials, 2.7%), protocol-defined nonprimary outcome reported as primary outcome in publication (4 trials, 1.3%), and different timing of assessment of primary outcome (4 trials, 1.3%). Out of trials with discrepancies in primary outcome, 15 trials (60.0%) had discrepancies that favored statistically significant results. Registration could be seen as a valid surrogate of protocol in 237 of 299 trials (79.3%) with regard to primary outcome. Despite unrestricted public access to protocols, selective outcome reporting persists in a small fraction of phase III RCTs. Only studies from four leading journals were included, which may cause selection bias and limit the generalizability of this finding. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. A prospective group sequential study evaluating a new type of fully covered self-expandable metal stent for the treatment of benign biliary strictures (with video).

    PubMed

    Poley, Jan-Werner; Cahen, Djuna L; Metselaar, Herold J; van Buuren, Henk R; Kazemier, Geert; van Eijck, Casper H J; Haringsma, Jelle; Kuipers, Ernst J; Bruno, Marco J

    2012-04-01

    Fully-covered self expandable metal stents (fcSEMSs) are an alternative to progressive plastic stenting for the treatment of benign biliary strictures (BBS) with the prospect of a higher treatment efficacy and the need for fewer ERCPs, thereby reducing the burden for patients and possibly costs. Key to this novel treatment is safe stent removal. To investigate the feasibility and safety of stent removal of a fcSEMS with a proximal retrieval lasso: a long wire thread integrated in the proximal ends of the wire mesh that hangs freely in the stent lumen. Pulling it enables gradual removal of the stent inside-out. A secondary aim was success of stricture resolution. Non-randomized, prospective follow-up study with 3 sequential cohorts of 8 patients with BBS. Academic tertiary referral center. Eligible patients had strictures either postsurgical (post-cholecystectomy (LCx) or liver transplantation (OLT)), due to chronic pancreatitis (CP), or papillary stenosis (PF). Strictures had to be located at least 2 cm below the liver hilum. All patients had one plastic stent in situ across the stricture and had not undergone previous treatment with either multiple plastic stents or fcSEMS. The first cohort of patients underwent stent placement for 2 months, followed by 3 months if the stricture had not resolved. The second and third cohort started with 3 months and 4 months, respectively, both followed by another 4 months if indicated. Treatment success was defined by stricture resolution at cholangiography, the ability to pass an inflated extraction balloon and clinical follow-up (at least 6 months). safety of stent removal. Secondary outcomes were complications and successful stricture resolution. A total of 23 patients (11 female; 20-67 yrs) were eligible for final analysis. One patient developed a malignant neuroendocrine tumor in the setting of CP. Strictures were caused by CP (13), OLT (6), LCx (3) and PF (1). In total 39 fcSEMS were placed and removed. Removals were easy and without complications. Transient pain after insertion was common (13 of 23/56%) but was easily managed by analgesics in all patients. Other complications were cholecystitis (1), cholangitis due to stent migration (1, stent replaced) or stent clogging (2, managed endoscopically) and worsening of CP (2). In these patients, the fcSEMS was removed and replaced after pancreatic sphincterotomy and PD stent placement. Median follow-up was 15 months (range 11-25). Overall treatment success was 61% (14/23); in the CP group 46%, in the remaining patients 80% (p = 0.11). Patients with stricture resolution after removal of the first stent (n = 7; success 6/7) showed a trent towards a more sustained treatment success than patients who needed a 2nd stent placement (n = 16; success 8/16); p = 0.12). Small number of patients with regard to secondary outcomes. Removal of a new type of fcSEMS with a proximal retrieval lasso in patients with BBS proved easy and uncomplicated. Treatment success for CP strictures was higher compared to what is known from results of progressive plastic stenting protocols. For other indications treatment success was comparable to progressive plastic stenting, but with the prospect of fewer ERCP procedures. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. Endoscopic findings following retroperitoneal pancreas transplantation.

    PubMed

    Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M

    2017-07-01

    An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. The Effects of Intra-Aortic Balloon Pumps on Mortality in Patients Undergoing High-Risk Coronary Revascularization: A Meta-Analysis of Randomized Controlled Trials of Coronary Artery Bypass Grafting and Stenting Era

    PubMed Central

    Wan, You-Dong; Sun, Tong-Wen; Kan, Quan-Cheng; Guan, Fang-Xia; Liu, Zi-Qi; Zhang, Shu-Guang

    2016-01-01

    Background Intra-aortic balloon pumps (IABP) have generally been used for patients undergoing high-risk mechanical coronary revascularization. However, there is still insufficient evidence to determine whether they can improve outcomes in reperfusion therapy patients, mainly by percutaneous coronary intervention (PCI) with stenting or coronary artery bypass graft (CABG). This study was designed to determine the difference between high-risk mechanical coronary revascularization with and without IABPs on mortality, by performing a meta-analysis on randomized controlled trials of the current era. Methods Pubmed and Embase databases were searched from inception to May 2015. Unpublished data were obtained from the investigators. Randomized clinical trials of IABP and non-IABP in high-risk coronary revascularization procedures (PCI or CABG) were included. In the case of PCI procedures, stents should be used in more than 80% of patients. Numbers of events at the short-term and long-term follow-up were extracted. Results A total of 12 randomized trials enrolling 2155 patients were included. IABPs did not significantly decrease short-term mortality (relative risk (RR) 0.66; 95% CI, 0.42–1.01), or long-term mortality (RR 0.79; 95% CI, 0.47–1.35), with low heterogeneity across the studies. The findings remained stable in patients with acute myocardial infarction with or without cardiogenic shock. But in high-risk CABG patients, IABP was associated with reduced mortality (71 events in 846 patients; RR 0.40; 95%CI 0.25–0.67). Conclusion In patients undergoing high-risk coronary revascularization, IABP did not significantly decrease mortality. But high-risk CABG patients may be benefit from IABP. Rigorous criteria should be applied to the use of IABPs. PMID:26784578

  15. Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions: an in vitro comparison study.

    PubMed

    Gitsioudis, Gitsios; Fortner, Philipp; Stuber, Matthias; Missiou, Anna; Andre, Florian; Müller, Oliver J; Katus, Hugo A; Korosoglou, Grigorios

    2016-11-01

    To compare the value of inversion recovery with on-resonant water suppression (IRON) to conventional T1-weighted (T1w) MRA and computed tomography angiography (CTA) for visualization of peripheral nitinol stents. We visualized 14 different peripheral nitinol stents in vitro both using Gadolinium (Gd) and ultrasmall superparamagnetic iron nanoparticles (USPIOs) for conventional T1w and IRON-MRA using clinical grade 1.5T MR scanner and iodinated contrast material for CTA using a 256-slice CT scanner. Parameter assessment included signal- and contrast-to-noise ratio (S/CNR), relative in-stent signal and artificial lumen narrowing. X-ray angiography served as gold standard for diameter assessment. Gd-enhanced IRON-MRA exhibited highest in-stent SNR and CNR values compared to conventional T1w MRA (IRON (Gd/USPIO): SNR = 30 ± 3/21 ± 2, CNR = 23 ± 2/14 ± 1; T1w: SNR = 16 ± 1/14 ± 2, CNR = 12 ± 1/10 ± 1, all p < 0.05). Furthermore, IRON-MRA achieved highest relative in-stent signal both using Gd and USPIO (IRON (Gd/USPIO): 121 ± 8 %/103 ± 6 %; T1w: 73 ± 2 %/66 ± 4 %; CTA: 84 ± 6 %, all p < 0.05). However, artificial lumen narrowing appeared similar in all imaging protocols (IRON (Gd/USPIO): 21 ± 3 %/21 ± 2 %; T1w: 16 ± 4 %/17 ± 3 %; CTA: 19 ± 2 %, all p = NS). Finally, IRON-MRA provided improvement of the in-stent lumen visualization with an 'open-close-open' design, which revealed a complete in-stent signal loss in T1w MRA. IRON-MRA improves in-stent visualization in vitro compared to conventional T1w MRA and CTA. In light of the in vitro results with Gd-enhanced IRON-MRA, the clinical implementation of such an approach appears promising.

  16. JetStream Rotational and Aspiration Atherectomy in Treating In-Stent Restenosis of the Femoropopliteal Arteries: Results of the JETSTREAM-ISR Feasibility Study.

    PubMed

    Shammas, Nicolas W; Shammas, Gail A; Banerjee, Subhash; Popma, Jeffrey J; Mohammad, Atif; Jerin, Michael

    2016-04-01

    To evaluate the outcomes and stent-device interaction of the JetStream atherectomy device in the treatment of in-stent restenosis (ISR) of the femoropopliteal segment. The JetStream XC atherectomy device, a rotational cutter with aspiration capacity, was evaluated in a prospective cohort of 29 patients (mean age 69.9 ± 11.7 years; 11 men) with femoropopliteal ISR in 32 limbs (ClinicalTrials.gov identifier NCT01722877). Lesion length was 17.4 ± 13.1 cm. The primary effectiveness outcome was acute success (≤ 30% residual narrowing with no serious adverse events). The primary safety endpoint was major adverse events. Secondary endpoints included clinically driven target lesion revascularization (TLR) at 6 months and 1 year and loss of stent integrity as assessed by an angiographic core laboratory. Treated length was 19.5 ± 12.9 cm. Acute success was obtained in 29/32 (91%) limbs. Acute device success (<50% residual narrowing after atherectomy alone) was 76% (22/29). Adjunctive balloon angioplasty was performed in all cases at a mean pressure of 11.6 ± 3.3 atm. Embolic filter protection was used in 16 (50%) of 32 limbs. Macrodebris was noted in 2 (12%) of 16 filters. Distal embolization requiring treatment occurred in 3/32 (9.4%) limbs (2 with no filter). Other non-procedure-related adverse events were 1 (3%) death (nonvascular) and 1 (3%) case of major bleeding. There were no new stent fractures or deformities (n=24) postatherectomy. Follow-up was completed on 27 patients (29 limbs) at 6 and 12 months. TLR at these time points occurred in 4/29 (14%) and 12/29 (41%) patients. Patency (duplex-derived peak systolic velocity ratio <2.4) was 72% at 6 months. JetStream atherectomy using the XC device has favorable acute results in treating femoropopliteal ISR with high procedure success, no device-stent interaction, and favorably low TLR rates. A multicenter trial is needed to confirm these results. © The Author(s) 2016.

  17. Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease.

    PubMed

    Ellis, Stephen G; Kereiakes, Dean J; Metzger, D Christopher; Caputo, Ronald P; Rizik, David G; Teirstein, Paul S; Litt, Marc R; Kini, Annapoorna; Kabour, Ameer; Marx, Steven O; Popma, Jeffrey J; McGreevy, Robert; Zhang, Zhen; Simonton, Charles; Stone, Gregg W

    2015-11-12

    In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).

  18. Incidence of urinary extravasation and rate of ureteral stenting after high-grade renal trauma in adults: a meta-analysis

    PubMed Central

    Anderson, Ross E.; Fiander, Michelle; McFarland, Mary M.; Stoddard, Gregory J.; Hotaling, James M.; Myers, Jeremy B.

    2018-01-01

    Background Collecting system injury and urinary extravasation is an important yet understudied aspect of renal trauma. We aimed to examine the incidence of urinary extravasation and also the rates of ureteral stenting after high-grade renal trauma (HGRT) in adults. Methods A search strategy was developed to search Ovid Medline, Embase, CINAHL, and Cochrane Library. Two reviewers screened titles and abstracts, followed by full-text review of the relevant publications. Studies were included if they indicated the number of patients with HGRT [the American Association for the Surgery of Trauma (AAST) grades III–IV or equivalents] and number of patients with urinary extravasation. A descriptive meta-analysis of binary proportions was performed with random-effects model to calculate the incidence of urinary extravasation and rates of ureteral stenting. Results After screening, 24 and 20 studies were included for calculating urinary extravasation and stenting rates, respectively. Most studies involved blunt injury and were retrospective single-center case series. Incidence of urinary extravasation was 29% (95% CI: 17–42%) after HGRT (grade III–V), and 51% (95% CI: 38–64%) when only grade IV–V injuries were combined. Overall, 29% (95% CI: 22–36%) of patients with urinary extravasation underwent ureteral stenting. Conclusions Approximately 30% of patients with HGRT are diagnosed with urinary extravasation and 29% of those with urinary extravasation undergo ureteral stenting. Understanding the rate of urinary extravasation and interventions is the first step in creating a prospective trial designed to demonstrate when ureteral stenting and aggressive management of urinary extravasation is needed. PMID:29928614

  19. Incidence of urinary extravasation and rate of ureteral stenting after high-grade renal trauma in adults: a meta-analysis.

    PubMed

    Keihani, Sorena; Anderson, Ross E; Fiander, Michelle; McFarland, Mary M; Stoddard, Gregory J; Hotaling, James M; Myers, Jeremy B

    2018-05-01

    Collecting system injury and urinary extravasation is an important yet understudied aspect of renal trauma. We aimed to examine the incidence of urinary extravasation and also the rates of ureteral stenting after high-grade renal trauma (HGRT) in adults. A search strategy was developed to search Ovid Medline, Embase, CINAHL, and Cochrane Library. Two reviewers screened titles and abstracts, followed by full-text review of the relevant publications. Studies were included if they indicated the number of patients with HGRT [the American Association for the Surgery of Trauma (AAST) grades III-IV or equivalents] and number of patients with urinary extravasation. A descriptive meta-analysis of binary proportions was performed with random-effects model to calculate the incidence of urinary extravasation and rates of ureteral stenting. After screening, 24 and 20 studies were included for calculating urinary extravasation and stenting rates, respectively. Most studies involved blunt injury and were retrospective single-center case series. Incidence of urinary extravasation was 29% (95% CI: 17-42%) after HGRT (grade III-V), and 51% (95% CI: 38-64%) when only grade IV-V injuries were combined. Overall, 29% (95% CI: 22-36%) of patients with urinary extravasation underwent ureteral stenting. Approximately 30% of patients with HGRT are diagnosed with urinary extravasation and 29% of those with urinary extravasation undergo ureteral stenting. Understanding the rate of urinary extravasation and interventions is the first step in creating a prospective trial designed to demonstrate when ureteral stenting and aggressive management of urinary extravasation is needed.

  20. Partially covered self-expandable metal stents versus polyethylene stents for malignant biliary obstruction: A cost-effectiveness analysis

    PubMed Central

    Barkun, Alan N; Adam, Viviane; Martel, Myriam; AlNaamani, Khalid; Moses, Peter L

    2015-01-01

    BACKGROUND/OBJECTIVE: Partially covered self-expandable metal stents (SEMS) and polyethylene stents (PES) are both commonly used in the palliation of malignant biliary obstruction. Although SEMS are significantly more expensive, they are more efficacious than PES. Accordingly, a cost-effectiveness analysis was performed. METHODS: A cost-effectiveness analysis compared the approach of initial placement of PES versus SEMS for the study population. Patients with malignant biliary obstruction underwent an endoscopic retrograde cholangiopancreatography to insert the initial stent. If the insertion failed, a percutaneous transhepatic cholangiogram was performed. If stent occlusion occurred, a PES was inserted at repeat endoscopic retrograde cholangiopancreatography, either in an outpatient setting or after admission to hospital if cholangitis was present. A third-party payer perspective was adopted. Effectiveness was expressed as the likelihood of no occlusion over the one-year adopted time horizon. Probabilities were based on a contemporary randomized clinical trial, and costs were issued from national references. Deterministic and probabilistic sensitivity analyses were performed. RESULTS: A PES-first strategy was both more expensive and less efficacious than an SEMS-first approach. The mean per-patient costs were US$6,701 for initial SEMS and US$20,671 for initial PES, which were associated with effectiveness probabilities of 65.6% and 13.9%, respectively. Sensitivity analyses confirmed the robustness of these results. CONCLUSION: At the time of initial endoscopic drainage for patients with malignant biliary obstruction undergoing palliative stenting, an initial SEMS insertion approach was both more effective and less costly than a PES-first strategy. PMID:26125107

  1. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    PubMed

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  2. Multicenter trial evaluating the use of covered self-expanding metal stents in benign biliary strictures: time to revisit our therapeutic options?

    PubMed

    Kahaleh, Michel; Brijbassie, Alan; Sethi, Amrita; Degaetani, Marisa; Poneros, John M; Loren, David E; Kowalski, Thomas E; Sejpal, Divyesh V; Patel, Sandeep; Rosenkranz, Laura; McNamara, Kevin N; Raijman, Isaac; Talreja, Jayant P; Gaidhane, Monica; Sauer, Bryan G; Stevens, Peter D

    2013-09-01

    Covered self-expanding metal stents are being used more frequently in benign biliary strictures (BBS). We report the results of a multicenter study with fully covered self-expanding metal stent (FCSEMS) placement for the management of BBS. : To prospectively evaluate the efficacy and safety of FCSEMS in the management of BBS. Patients with BBS from 6 tertiary care centers who received FCSEMS with flared ends between April 2009 and October 2010 were included in this retrospective study.Efficacy was measured after removal of FCSEMS by evaluating stricture resolution on the basis of symptom resolution, imaging, laboratory studies, and/or choledochoscopy at removal. Safety profile was evaluated by assessing postprocedural complications. A total of 133 patients (78, 58.6% males) with a mean age of 59.2±14.8 years with BBS received stents. Of the 133 stents placed, 97 (72.9%) were removed after a mean stent duration of 95.5±48.7 days. Stricture resolution after FCSEMS removal was as follows: postsurgical, 11/12 (91.6%); gallstone-related disease, 16/19 (84.2%); chronic pancreatitis, 26/31 (80.7%); other etiology, 4/5 (80.0%); and anastomotic strictures, 19/31(61.2%). Ninety-four patients were included in the logistic regression analyses. Patients who had indwelling stents for >90 days were 4.3 times more likely to have resolved strictures [odds ratio, 4.3 (95% confidence interval, 1.24-15.09)] and patients with nonmigrated stents were 5.4 times more likely to have resolved strictures [odds ratio, 5.4 (95% confidence interval, 1.001-29.29)]. FCSEMS for BBS had an acceptable rate of stricture resolution for postsurgical strictures, gallstone-related strictures, and those due to chronic pancreatitis. Predictors for stricture resolution include longer indwell time and absence of migration. Further study is warranted to assess long-term efficacy in a prospective manner with longer than 3-month time of stent indwelling time.

  3. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.

    PubMed

    Poerner, Tudor C; Otto, Sylvia; Gassdorf, Johannes; Nitsche, Kristina; Janiak, Florian; Scheller, Bruno; Goebel, Björn; Jung, Christian; Figulla, Hans R

    2014-12-01

    In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64±9.65% in BMS+DEB versus 4.93±9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7±7.8 versus 11.0±5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8±11.9 versus 16.9±10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5±13.8% versus 36.8±15.6%; P=0.409) was found. Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up. http://www.clinicaltrials.gov. Unique identifier: NCT01056744. © 2014 American Heart Association, Inc.

  4. The predictive value of haemodynamic parameters for outcome of deep venous reconstructions in patients with chronic deep vein obstruction - A systematic review.

    PubMed

    Kurstjens, Rlm; de Wolf, Maf; Kleijnen, J; de Graaf, R; Wittens, Cha

    2017-09-01

    Objective The aim of this study was to investigate the predictive value of haemodynamic parameters on success of stenting or bypass surgery in patients with non-thrombotic or post-thrombotic deep venous obstruction. Methods EMBASE, MEDLINE and trial registries were searched up to 5 February 2016. Studies needed to investigate stenting or bypass surgery in patients with post-thrombotic obstruction or stenting for non-thrombotic iliac vein compression. Haemodynamic data needed to be available with prognostic analysis for success of treatment. Two authors, independently, selected studies and extracted data with risk bias assessment using the Quality in Prognosis Studies tool. Results Two studies using stenting and two using bypass surgery were included. Three investigated plethysmography, though results varied and confounding was not properly taken into account. Dorsal foot vein pressure and venous refill times appeared to be of influence in one study, though confounding by deep vein incompetence was likely. Another investigated femoral-central pressure gradients without finding statistical significance, though sample size was small without details on statistical methodology. Reduced femoral inflow was found to be a predictor for stent stenosis or occlusion in one study, though patients also received additional surgery to improve stent inflow. Data on prediction of haemodynamic parameters for stenting of non-thrombotic iliac vein compression were not available. Conclusions Data on the predictive value of haemodynamic parameters for success of treatment in deep venous obstructive disease are scant and of poor quality. Plethysmography does not seem to be of value in predicting outcome of stenting or bypass surgery in post-thrombotic disease. The relevance of pressure-related parameters is unclear. Reduced flow into the common femoral vein seems to be predictive for in-stent stenosis or occlusion. Further research into the predictive effect of haemodynamic parameters is warranted and the possibility of developing new techniques that evaluate various haemodynamic aspects should be explored.

  5. Relationship between risk factor control and vascular events in the SAMMPRIS trial

    PubMed Central

    Nizam, Azhar; Lynn, Michael J.; Egan, Brent M.; Le, Ngoc-Anh; Lopes-Virella, Maria F.; Hermayer, Kathie L.; Harrell, Jamie; Derdeyn, Colin P.; Fiorella, David; Janis, L. Scott; Lane, Bethany; Montgomery, Jean; Chimowitz, Marc I.

    2017-01-01

    Objective: The Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis (SAMMPRIS) study is the first stroke prevention trial to include protocol-driven intensive management of multiple risk factors. In this prespecified analysis, we aimed to investigate the relationship between risk factor control during follow-up and outcome of patients in the medical arm of SAMMPRIS. Methods: Data from SAMMPRIS participants in the medical arm (n = 227) were analyzed. Risk factors were recorded at baseline, 30 days, 4 months, and then every 4 months for a mean follow-up of 32 months. For each patient, values for all risk factor measures were averaged and dichotomized as in or out of target. Results: Participants who were out of target for systolic blood pressure and physical activity, as well as those with higher mean low-density lipoprotein cholesterol and non–high-density lipoprotein, were more likely to have a recurrent vascular event (stroke, myocardial infarction, or vascular death) at 3 years compared to those who had good risk factor control. In the multivariable analysis, greater physical activity decreased the likelihood of a recurrent stroke, myocardial infarction, or vascular death (odds ratio 0.6, confidence interval 0.4–0.8). Conclusions: Raised blood pressure, cholesterol, and physical inactivity should be aggressively treated in patients with intracranial atherosclerosis to prevent future vascular events. Physical activity, which has not received attention in stroke prevention trials, was the strongest predictor of a good outcome in the medical arm in SAMMPRIS. ClinicalTrials.gov identifier: NCT00576693. PMID:28003500

  6. Evaluation of the safety and efficacy of an edoxaban-based antithrombotic regimen in patients with atrial fibrillation following successful percutaneous coronary intervention (PCI) with stent placement: Rationale and design of the ENTRUST-AF PCI trial.

    PubMed

    Vranckx, Pascal; Lewalter, Thorsten; Valgimigli, Marco; Tijssen, Jan G; Reimitz, Paul-Egbert; Eckardt, Lars; Lanz, Hans-Joachim; Zierhut, Wolfgang; Smolnik, Rüdiger; Goette, Andreas

    2018-02-01

    The optimal antithrombotic treatment after percutaneous coronary intervention (PCI) with stenting in patients with atrial fibrillation (AF) is unknown. In the ENGAGE AF-TIMI 48 trial, edoxaban was noninferior to a vitamin K antagonist (VKA) with respect to the prevention of stroke or systemic embolism and was associated with significantly lower rates of bleeding and cardiovascular death in patients with nonvalvular AF. The effects of edoxaban in combination with single- or dual-antiplatelet therapy in the setting of PCI are unexplored. The ENTRUST-AF PCI trial is a multinational, multicenter, randomized, open-label phase 3b trial with blinded end point evaluation involving 1,500 patients on oral anticoagulation for AF. Patients are randomized between 4 hours and 5 days after successful PCI to either an edoxaban-based strategy (experimental arm; 60 mg [or 30 mg according to dose reduction criteria] once daily plus a P2Y 12 antagonist [default clopidogrel, 75 mg once daily] for 12 months) or a VKA-based strategy (control arm; VKA plus a P2Y 12 antagonist [as above] plus acetylsalicylic acid [100 mg once daily] for 30 days to 12 months). The primary safety end point is the incidence of International Society on Thrombosis and Haemostasis-defined major or clinically relevant nonmajor bleeding. The main efficacy end point is the composite of cardiovascular death, stroke, systemic embolic events, spontaneous myocardial infarction, and definite stent thrombosis. The ENTRUST-AF PCI trial tests the hypothesis that an edoxaban-based antithrombotic strategy reduces the risk of bleeding complications after PCI compared with VKA plus conventional dual-antiplatelet therapy in patients with AF in need of oral anticoagulation. The relative risk of ischemic events between groups will be compared. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. The role of advanced reconstruction algorithms in cardiac CT

    PubMed Central

    Halliburton, Sandra S.; Tanabe, Yuki; Partovi, Sasan

    2017-01-01

    Non-linear iterative reconstruction (IR) algorithms have been increasingly incorporated into clinical cardiac CT protocols at institutions around the world. Multiple IR algorithms are available commercially from various vendors. IR algorithms decrease image noise and are primarily used to enable lower radiation dose protocols. IR can also be used to improve image quality for imaging of obese patients, coronary atherosclerotic plaques, coronary stents, and myocardial perfusion. In this article, we will review the various applications of IR algorithms in cardiac imaging and evaluate how they have changed practice. PMID:29255694

  8. Paclitaxel-Eluting Balloon Versus Standard Balloon Angioplasty in In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Artery: 1-Year Results of the PACUBA Trial.

    PubMed

    Kinstner, Christian M; Lammer, Johannes; Willfort-Ehringer, Andrea; Matzek, Wolfgang; Gschwandtner, Michael; Javor, Domagoj; Funovics, Martin; Schoder, Maria; Koppensteiner, Renate; Loewe, Christian; Ristl, Robin; Wolf, Florian

    2016-07-11

    The hypothesis that paclitaxel-eluting balloon angioplasty provides higher 1-year patency rates in femoropopliteal artery in-stent restenosis compared with standard percutaneous transluminal angioplasty (PTA) was tested. Several trials have demonstrated that paclitaxel-eluting balloon angioplasty reduces late luminal loss in comparison with PTA. In a prospective, randomized, single-blind, dual-center study, 74 patients with symptomatic peripheral artery disease due to in-stent restenosis were treated with either paclitaxel-based drug-eluting balloon (DEB) angioplasty (n = 35) or standard PTA (n = 39). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. The mean lesion length was 17.3 ± 11.3 cm in the DEB group and 18.4 ± 8.8 cm in the PTA group. A single major complication (bleeding) was observed once (1.4%). The mean ankle-brachial index before endovascular treatment was 0.65 ± 0.16 in both groups and 0.79 ± 0.2 versus 0.84 ± 0.3 (p = 0.70, Student t test) in the DEB versus PTA group at 12 months. The 12-month primary patency rates were 40.7% (95% confidence interval [CI]: 0.26 to 0.64) versus 13.4% (95% CI: 0.05 to 0.36) (log-rank p = 0.02) in the DEB versus PTA group. The odds ratio for PTA over DEB angioplasty for experiencing an event was estimated at 2.8 (95% CI: 1.2 to 6.6). Freedom from clinically driven target lesion revascularization was 49.0% (95% CI: 0.32 to 0.75) versus 22.1% (95% CI: 0.10 to 0.48) (log-rank p = 0.11) in the DEB versus PTA group. Clinical improvement by ≥1 Rutherford-Becker category was 68.8% versus 54.5% (p = 0.87) in the DEB versus PTA group at 12 months. When treating peripheral artery disease in patients with in-stent restenosis in the femoropopliteal artery, paclitaxel-eluting balloon angioplasty provides significantly higher patency rates than standard PTA. (Paclitaxel Balloon Versus Standard Balloon in In-Stent Restenoses of the Superficial Femoral Artery [PACUBA I Trial] [PACUBA 1]; NCT01247402). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Real‐World Multicenter Registry of Patients with Severe Coronary Artery Calcification Undergoing Orbital Atherectomy

    PubMed Central

    Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard

    2016-01-01

    Objectives We evaluated the safety and efficacy of orbital atherectomy in real‐world patients with severe coronary artery calcification (CAC). Background The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. Methods This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. Results The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30‐day all‐cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no‐reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. Conclusion In the largest real‐world study of patients who underwent orbital atherectomy, including high‐risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short‐term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. PMID:27358246

  10. Drug-coated balloons for de novo lesions in small coronary arteries: rationale and design of BASKET-SMALL 2.

    PubMed

    Gilgen, Nicole; Farah, Ahmed; Scheller, Bruno; Ohlow, Marc-Alexander; Mangner, Norman; Weilenmann, Daniel; Wöhrle, Jochen; Jamshidi, Peiman; Leibundgut, Gregor; Möbius-Winkler, Sven; Zweiker, Robert; Krackhardt, Florian; Butter, Christian; Bruch, Leonhard; Kaiser, Christoph; Hoffmann, Andreas; Rickenbacher, Peter; Mueller, Christian; Stephan, Frank-Peter; Coslovsky, Michael; Jeger, Raban

    2018-05-01

    The treatment of coronary small vessel disease (SVD) remains an unresolved issue. Drug-eluting stents (DES) have limited efficacy due to increased rates of instent-restenosis, mainly caused by late lumen loss. Drug-coated balloons (DCB) are a promising technique because native vessels remain structurally unchanged. Basel Stent Kosten-Effektivitäts Trial: Drug-Coated Balloons vs. Drug-Eluting Stents in Small Vessel Interventions (BASKET-SMALL 2) is a multicenter, randomized, controlled, noninferiority trial of DCB vs DES in native SVD for clinical endpoints. Seven hundred fifty-eight patients with de novo lesions in vessels <3 mm in diameter and an indication for percutaneous coronary intervention such as stable angina pectoris, silent ischemia, or acute coronary syndromes are randomized 1:1 to angioplasty with DCB vs implantation of a DES after successful initial balloon angioplasty. The primary endpoint is the combination of cardiac death, nonfatal myocardial infarction, and target-vessel revascularization up to 1 year. Secondary endpoints include stent thrombosis, Bleeding Academic Research Consortium (BARC) type 3 to 5 bleeding, and long-term outcome up to 3 years. Based on clinical endpoints after 1 year, we plan to assess the noninferiority of DCB compared to DES in patients undergoing primary percutaneous coronary intervention for SVD. Results will be available in the second half of 2018. This study will compare DCB and DES regarding long-term safety and efficacy for the treatment of SVD in a large all-comer population. © 2018 The Authors. Clinical Cardiology published by Wiley Periodicals, Inc.

  11. Stenting Prior to Cystectomy is an Independent Risk Factor for Upper Urinary Tract Recurrence.

    PubMed

    Kiss, Bernhard; Furrer, Marc A; Wuethrich, Patrick Y; Burkhard, Fiona C; Thalmann, George N; Roth, Beat

    2017-12-01

    Patients with bladder cancer who present with hydronephrosis may require drainage of the affected kidney before receiving further cancer treatment. Drainage can be done by retrograde stenting or percutaneously. However, retrograde stenting carries the risk of tumor cell spillage to the upper urinary tract. The aim of this study was to evaluate whether patients with bladder cancer are at higher risk for upper urinary tract recurrence if retrograde stenting has been performed prior to radical cystectomy. We retrospectively analyzed the records of 1,005 consecutive patients with bladder cancer who underwent radical cystectomy at our department between January 2000 and June 2016. Negative intraoperative ureteral margins were mandatory for study inclusion. Patients received regular followup according to our institutional protocol, including imaging of the upper urinary tract and urine cytology. Preoperative drainage of the upper urinary tract was performed in 114 of the 1,005 patients (11%), including in 53 (46%) by Double-J® stenting and in 61 (54%) by percutaneous nephrostomy. Recurrence developed in the upper urinary tract in 31 patients (3%) at a median of 17 months after cystectomy, including 7 of 53 (13%) in the Double-J group, 0% in the nephrostomy group and 24 of 891 (3%) in the no drainage group. Multivariate regression analysis revealed a higher risk of upper urinary tract recurrence if patients underwent Double-J stenting (HR 4.54, 95% CI 1.43-14.38, p = 0.01) and preoperative intravesical instillations (HR 2.94, 95% CI 1.40-6.16, p = 0.004). Patients who undergo Double-J stenting prior to radical cystectomy are at higher risk for upper urinary tract recurrence. If preoperative upper urinary tract drainage is required, percutaneous drainage might be recommended. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients.

    PubMed

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G; Goldberg, Paul; Casellas, Juan A; Roncero, Oscar; Grund, Karl E; Alvarez, Alberto; García-Cano, Jesús; Vázquez-Astray, Enrique; Jiménez-Pérez, Javier

    2011-10-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery. To document performance, safety, and effectiveness of colorectal stents used per local standards of practice in patients with malignant large-bowel obstruction to avoid palliative stoma surgery in incurable patients (PAL) and facilitate bowel decompression as a bridge to surgery for curable patients (BTS). Prospective clinical cohort study. Two global registries with 39 academic and community centers. This study involved 447 patients with malignant colonic obstruction who received stents (255 PAL, 182 BTS, 10 no indication specified). Colorectal through-the-scope SEMS placement. The primary endpoint was clinical success at 30 days, defined as the patient's ability to maintain bowel function without adverse events related to the procedure or stent. Secondary endpoints were procedural success, defined as successful stent placement in the correct position, symptoms of persistent or recurrent colonic obstruction, and complications. The procedural success rate was 94.8% (439/463), and the clinical success rates were 90.5% (313/346) as assessed on a per protocol basis and 71.6% (313/437) as assessed on an intent-to-treat basis. Complications included 15 (3.9%) perforations, 3 resulting in death, 7 (1.8%) migrations, 7 (1.8%) cases of pain, and 2 (0.5%) cases of bleeding. No control group. No primary endpoint analysis data for 25% of patients. This largest multicenter, prospective study of colonic SEMS placement demonstrates that colonic SEMSs are safe and highly effective for the short-term treatment of malignant colorectal obstruction, allowing most curable patients to have 1-step resection without stoma and providing most incurable patients minimally invasive palliation instead of surgery. The risk of complications, including perforation, was low. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in all-comers population. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry).

    PubMed

    Godino, Cosmo; Beneduce, Alessandro; Ferrante, Giuseppe; Ielasi, Alfonso; Pivato, Andrea Carlo; Chiarito, Mauro; Cappelletti, Alberto; Perfetti, Giulia; Magni, Valeria; Prati, Eugenio; Falcone, Stefania; Pierri, Adele; De Martini, Stefano; Montorfano, Matteo; Parisi, Rosario; Rutigliano, David; Locuratolo, Nicola; Anzuini, Angelo; Tespilli, Maurizio; Margonato, Alberto; Benassi, Alberto; Briguori, Carlo; Fabbiocchi, Franco; Reimers, Bernhard; Bartorelli, Antonio; Colombo, Antonio

    2018-06-01

    This study was designed to confirm in a large population of unselected patients the promising results of Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) already shown in previous trial. ULISSE is an observational, multicenter, national registry evaluating all patients undergoing PCI with the Ultimaster® BP-SES. Incidence of 1-year TLF (cardiac death or target vessel MI or clinically indicated TLR) was the primary endpoint. Pre-specified subgroup analysis was performed for diabetic patients and for those with lesion longer than 25 mm, bifurcation and CTO lesions. 1660 patients were enrolled in 9 Italian cardiology centers, 82% were males, mean age of 68 ± 10 years, and 29% were diabetics. Overall 2422 lesions were treated, 65% type B2/C lesions, 7% CTOs, 17% bifurcations and 38% long lesions. The incidence of 1-year TLF was 5%, with 3.2% of clinically indicated TLR. TLF occurred in 8% of the patients with diabetes mellitus, and 7% in bifurcation, 6.7% in CTO and 6.2% in long lesions. Definite overall ST was 0.9%, and 1.2% in patients treated for type B2/C lesions. Multivariate logistic regression analysis identified stenting on unprotected LMT (OR = 4.80), stenting on ISR lesion (OR = 3.19) and need for rotational atherectomy (OR = 6.24) as the strongest independent predictors of TLF. The results of this national all-comers registry show that the Ultimaster® BP-SES real-world performance was comparable with that observed in the clinical trial, with low rate of primary endpoint and TLR. Long term follow-up will be necessary to prove the theoretical advantage of the BP-SES over time. Copyright © 2017. Published by Elsevier B.V.

  14. Reporting on blinding in trial protocols and corresponding publications was often inadequate but rarely contradictory.

    PubMed

    Hróbjartsson, Asbjørn; Pildal, Julie; Chan, An-Wen; Haahr, Mette T; Altman, Douglas G; Gøtzsche, Peter C

    2009-09-01

    To compare the reporting on blinding in protocols and articles describing randomized controlled trials. We studied 73 protocols of trials approved by the scientific/ethical committees for Copenhagen and Frederiksberg, 1994 and 1995, and their corresponding publications. Three out of 73 trials (4%) reported blinding in the protocol that contradicted that in the publication (e.g., "open" vs. "double blind"). The proportion of "double-blind" trials with a clear description of the blinding of participants increased from 11 out of 58 (19%) when based on publications alone to 39 (67%) when adding the information in the protocol. The similar proportions for the blinding of health care providers were 2 (3%) and 22 (38%); and for the blinding of data collectors, they were 8 (14%) and 14 (24%). In 52 of 58 publications (90%), it was unclear whether all patients, health care providers, and data collectors had been blinded. In 4 of the 52 trials (7%), the protocols clarified that all three key trial persons had been blinded. The reporting on blinding in both trial protocols and publications is often inadequate. We suggest developing international guidelines for the reporting of trial protocols and public access to protocols.

  15. First Report of the Resolute Onyx 2.0-mm Zotarolimus-Eluting Stent for the Treatment of Coronary Lesions With Very Small Reference Vessel Diameter.

    PubMed

    Price, Matthew J; Saito, Shigeru; Shlofmitz, Richard A; Spriggs, Douglas J; Attubato, Michael; McLaurin, Brent; Popma Almonacid, Alexandra; Brar, Sandeep; Liu, Minglei; Moe, Elizabeth; Mehran, Roxana

    2017-07-24

    The aim of this study was to explore the safety and efficacy of a dedicated drug-eluting stent for the treatment of coronary lesions with very small reference vessel diameter (RVD). Smaller RVD is associated with increased risk for restenosis and target lesion failure (TLF) after stent implantation. This was a prospective, single-arm, multicenter trial of the Resolute Onyx 2.0-mm zotarolimus-eluting stent. The primary endpoint was 12-month TLF, which was compared with a pre-specified performance goal. Subjects with stable or unstable angina or ischemia, target lesions ≤27 mm in length, and RVD ≥2.0 and <2.25 mm were eligible for enrollment. A subset of subjects underwent follow-up angiography at 13 months post-procedure. A total of 101 subjects with 104 lesions were enrolled. The mean age was 67.3 ± 9.6 years, 47% of subjects had diabetes, the mean lesion length was 12.6 ± 6.3 mm, and the mean RVD was 1.91 ± 0.26 mm. The rate of TLF at 12 months was 5.0%, fulfilling the pre-specified performance goal of 19% (p < 0.001). The rates of target lesion revascularization and target vessel myocardial infarction were 2.0% and 3.0%, respectively. There were no episodes of stent thrombosis. In-stent late lumen loss was 0.26 ± 0.48 mm, and the rate of binary restenosis was 12.0%. In this first report of a drug-eluting stent with a dedicated size to treat lesions with RVD <2.25 mm, the Resolute Onyx 2.0-mm zotarolimus-eluting stent was associated with a low rate of TLF and late lumen loss, without a signal for stent thrombosis. This novel-sized drug-eluting stent appears to be a feasible option for the treatment of coronary lesions in extremely small vessels. (Medtronic Resolute Onyx 2.0 mm Clinical Study; NCT02412501). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Statistical controversies in clinical research: comparison of primary outcomes in protocols, public clinical-trial registries and publications: the example of oncology trials.

    PubMed

    Perlmutter, A S; Tran, V-T; Dechartres, A; Ravaud, P

    2017-04-01

    Protocols are often unavailable to peer-reviewers and readers. To detect outcome reporting bias (ORB), readers usually have to resort to publicly available descriptions of study design such as public clinical trial registries. We compared primary outcomes in protocols, ClinicalTrials.gov and publications of oncology trials and evaluated the use of ClinicalTrials.gov as compared with protocols in detecting discrepancies between planned and published outcomes. We searched for phase III oncology trials registered in ClinicalTrials.gov and published in the Journal of Clinical Oncology and New England Journal of Medicine between January 2014 and June 2015. We extracted primary outcomes reported in the protocol, ClinicalTrials.gov and the publication. First, we assessed the quality of primary outcome descriptions by using a published framework. Second, we evaluated modifications of primary outcomes between each source. Finally, we evaluated the agreement, specificity and sensitivity of detecting modifications between planned and published outcomes by using protocols or ClinicalTrials.gov. We included 65 trials, with 81 primary outcomes common among the 3 sources. The proportion of primary outcomes reporting all items from the framework was 73%, 22%, and 75% for protocols, ClinicalTrials.gov and publications, respectively. Eight (12%) trials presented a discrepancy between primary outcomes reported in the protocol and in the publication. Twelve (18.5%) trials presented a discrepancy between primary outcomes registered at ClinicalTrials.gov and in publications. We found a moderate agreement in detecting discrepant reporting of outcomes by using protocols or ClinicalTrials.gov [κ = 0.53, 95% confidence interval (0.25-0.81)]. Using ClinicalTrials.gov to detect discrepant reporting of outcomes showed high specificity (89.5%) but lacked sensitivity (75%) as compared with use of protocols. In oncology trials, primary outcome descriptions in ClinicalTrials.gov are often of low quality and may not reflect what is in the protocol, thus limiting the detection of modifications between planned and published outcomes. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. A novel animal model for hyperdynamic airway collapse.

    PubMed

    Tsukada, Hisashi; O'Donnell, Carl R; Garland, Robert; Herth, Felix; Decamp, Malcolm; Ernst, Armin

    2010-12-01

    Tracheobronchomalacia (TBM) is increasingly recognized as a condition associated with significant pulmonary morbidity. However, treatment is invasive and complex, and because there is no appropriate animal model, novel diagnostic and treatment strategies are difficult to evaluate. We endeavored to develop a reliable airway model to simulate hyperdynamic airway collapse in humans. Seven 20-kg male sheep were enrolled in this study. Tracheomalacia was created by submucosal resection of > 50% of the circumference of 10 consecutive cervical tracheal cartilage rings through a midline cervical incision. A silicone stent was placed in the trachea to prevent airway collapse during recovery. Tracheal collapsibility was assessed at protocol-specific time points by bronchoscopy and multidetector CT imaging while temporarily removing the stent. Esophageal pressure and flow data were collected to assess flow limitation during spontaneous breathing. All animals tolerated the surgical procedure well and were stented without complications. One sheep died at 2 weeks because of respiratory failure related to stent migration. In all sheep, near-total forced inspiratory airway collapse was observed up to 3 months postprocedure. Esophageal manometry demonstrated flow limitation associated with large negative pleural pressure swings during rapid spontaneous inhalation. Hyperdynamic airway collapse can reliably be induced with this technique. It may serve as a model for evaluation of novel diagnostic and therapeutic strategies for TBM.

  18. The cost-effectiveness of beta-radiation therapy for treatment of in-stent restenosis: an analysis at 290-day follow-up.

    PubMed

    Beusterien, Kathleen M; Plante, Kathryn M; Waksman, Ron; Raizner, Albert E; Annis, Marijke; Goss, Thomas F

    2002-01-01

    We studied the cost-effectiveness of percutaneous coronary intervention (PCI) plus beta-radiation (Radiotherapy) vs. PCI alone for treating in-stent restenosis. We analyzed medical resource data collected at US sites during the Intimal Hyperplasia Inhibition with beta In-stent Trial (INHIBIT) to compare the incremental costs between Radiotherapy and PCI alone for each repeat target lesion revascularization (TLR) avoided. Costs were assigned for cardiac-related medical services using the Medicare payer perspective. Radiotherapy increased initial inpatient costs by US$3360 (P<.001). In the Radiotherapy and PCI alone groups, the mean per-patient rates for TLR were 0.13 vs. 0.30 (P=.001), and mean per-patient total costs were US$19,286 vs. US$18,349 (P<.001), respectively. The incremental cost of Radiotherapy relative to PCI alone was US$5512 per TLR avoided, which compares favorably to the observed mean per-patient cost of treating restenosis (US$16,852). beta-radiation is a cost-effective adjunct to PCI in treating patients with in-stent restenosis.

  19. Relationship between risk factor control and vascular events in the SAMMPRIS trial.

    PubMed

    Turan, Tanya N; Nizam, Azhar; Lynn, Michael J; Egan, Brent M; Le, Ngoc-Anh; Lopes-Virella, Maria F; Hermayer, Kathie L; Harrell, Jamie; Derdeyn, Colin P; Fiorella, David; Janis, L Scott; Lane, Bethany; Montgomery, Jean; Chimowitz, Marc I

    2017-01-24

    The Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis (SAMMPRIS) study is the first stroke prevention trial to include protocol-driven intensive management of multiple risk factors. In this prespecified analysis, we aimed to investigate the relationship between risk factor control during follow-up and outcome of patients in the medical arm of SAMMPRIS. Data from SAMMPRIS participants in the medical arm (n = 227) were analyzed. Risk factors were recorded at baseline, 30 days, 4 months, and then every 4 months for a mean follow-up of 32 months. For each patient, values for all risk factor measures were averaged and dichotomized as in or out of target. Participants who were out of target for systolic blood pressure and physical activity, as well as those with higher mean low-density lipoprotein cholesterol and non-high-density lipoprotein, were more likely to have a recurrent vascular event (stroke, myocardial infarction, or vascular death) at 3 years compared to those who had good risk factor control. In the multivariable analysis, greater physical activity decreased the likelihood of a recurrent stroke, myocardial infarction, or vascular death (odds ratio 0.6, confidence interval 0.4-0.8). Raised blood pressure, cholesterol, and physical inactivity should be aggressively treated in patients with intracranial atherosclerosis to prevent future vascular events. Physical activity, which has not received attention in stroke prevention trials, was the strongest predictor of a good outcome in the medical arm in SAMMPRIS. NCT00576693. © 2016 American Academy of Neurology.

  20. Carotid Artery Stenting – Strategies to Improve Procedural Performance and Reduce the Learning Curve

    PubMed Central

    Van Herzeele, Isabelle

    2013-01-01

    Carotid artery stenting (CAS) remains an appealing intervention to reduce the stroke risk because of its minimal invasive nature. Nevertheless, landmark randomised controlled trials have not been able to resolve the controversies surrounding this complex procedure as the peri-operative stroke risk in a non-selected patient population still seems to be higher after CAS in comparison to carotid endarterectomy. What is more, these trials have highlighted that patient outcome after CAS is influenced by patient- and operator-dependant factors. The CAS procedure exhibits a definitive learning curve resulting in higher complication rates if the procedure is performed by inexperienced interventionists or in low-volume centres. This article will outline strategies to improve the performance of physicians carrying out the CAS procedure by means of proficiency-based training, credentialing, virtual reality rehearsal and optimal patient selection. PMID:29588751

  1. [Treatment of asymptomatic carotid artery stenosis: improvement of evidence with new SPACE-2 design necessary].

    PubMed

    Reiff, T; Amiri, H; Ringleb, P A; Jansen, O; Hacke, W; Eckstein, H H; Fraedrich, G; Mudra, H; Mansmann, U

    2013-12-01

    Asymptomatic carotid artery stenosis may be treated with carotid endarterectomy (CEA), carotid artery stenting (CAS) or with best medical treatment (BMT) only. Definitive and evidence-based treatment recommendations for one of these options are currently not possible. Studies showing an advantage of CEA over BMT alone do not meet current standards from a pharmacological point of view. On the other hand, more recent data point to a further stroke risk reduction using BMT according to current standards. Studies on carotid artery stenting as a third alternative treatment are partially insufficient, especially when comparing CAS with BMT. Initiated in 2009, the randomized, controlled, multicenter SPACE-2 trial is intended to answer the question about the best treatment option of asymptomatic carotid artery stenosis; however, to increase recruitment rates as a condition for the successful completion of this important study, the trial design had to be modified.

  2. Safety and Efficacy of Solitaire Stent Thrombectomy: Individual Patient Data Meta-Analysis of Randomized Trials.

    PubMed

    Campbell, Bruce C V; Hill, Michael D; Rubiera, Marta; Menon, Bijoy K; Demchuk, Andrew; Donnan, Geoffrey A; Roy, Daniel; Thornton, John; Dorado, Laura; Bonafe, Alain; Levy, Elad I; Diener, Hans-Christoph; Hernández-Pérez, María; Pereira, Vitor Mendes; Blasco, Jordi; Quesada, Helena; Rempel, Jeremy; Jahan, Reza; Davis, Stephen M; Stouch, Bruce C; Mitchell, Peter J; Jovin, Tudor G; Saver, Jeffrey L; Goyal, Mayank

    2016-03-01

    Recent positive randomized trials of endovascular therapy for ischemic stroke used predominantly stent retrievers. We pooled data to investigate the efficacy and safety of stent thrombectomy using the Solitaire device in anterior circulation ischemic stroke. Patient-level data were pooled from trials in which the Solitaire was the only or the predominant device used in a prespecified meta-analysis (SEER Collaboration): Solitaire FR With the Intention for Thrombectomy as Primary Endovascular Treatment (SWIFT PRIME), Endovascular Treatment for Small Core and Anterior Circulation Proximal Occlusion With Emphasis on Minimizing CT to Recanalization Times (ESCAPE), Extending the Time for Thrombolysis in Emergency Neurological Deficits-Intra-Arterial (EXTEND-IA), and Randomized Trial of Revascularization With Solitaire FR Device Versus Best Medical Therapy in the Treatment of Acute Stroke Due to Anterior Circulation Large Vessel Occlusion Presenting Within Eight Hours of Symptom Onset (REVASCAT). The primary outcome was ordinal analysis of modified Rankin Score at 90 days. The primary analysis included all patients in the 4 trials with 2 sensitivity analyses: (1) excluding patients in whom Solitaire was not the first device used and (2) including the 3 Solitaire-only trials (excluding ESCAPE). Secondary outcomes included functional independence (modified Rankin Score 0-2), symptomatic intracerebral hemorrhage, and mortality. The primary analysis included 787 patients: 401 randomized to endovascular thrombectomy and 386 to standard care, and 82.6% received intravenous thrombolysis. The common odds ratio for modified Rankin Score improvement was 2.7 (2.0-3.5) with no heterogeneity in effect by age, sex, baseline stroke severity, extent of computed tomography changes, site of occlusion, or pretreatment with alteplase. The number needed to treat to reduce disability was 2.5 and for an extra patient to achieve independent outcome was 4.25 (3.29-5.99). Successful revascularization occurred in 77% treated with Solitaire device. The rate of symptomatic intracerebral hemorrhage and overall mortality did not differ between treatment groups. Solitaire thrombectomy for large vessel ischemic stroke was safe and highly effective with substantially reduced disability. Benefits were consistent in all prespecified subgroups. © 2016 The Authors.

  3. Techniques in cerebral protection.

    PubMed

    Fanelli, Fabrizio; Bezzi, Mario; Boatta, Emanuele; Passariello, Roberto

    2006-10-01

    Carotid angioplasty and stenting is a valid alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis. During the stenting process, however, distal embolization can occur with neurological consequences. To avoid this, cerebral protection devices have been introduced. Three principal types of protection system have been developed: distal balloon occlusion, distal filters and proximal protection with or without reversal of flow. As protection devices became the focus of interest by manufactures and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy to reduce the rate of distal embolization.

  4. Apollo stent for symptomatic atherosclerotic intracranial stenosis: study results.

    PubMed

    Jiang, W-J; Xu, X-T; Jin, M; Du, B; Dong, K-H; Dai, J-P

    2007-05-01

    A recent trial shows an 8.3 per 100-patient-years' ischemic stroke rate in the territory of the intracranial stenotic artery, despite aspirin treatment. Our aim was to prospectively study the feasibility and outcome of a new intracranial balloon-expandable Apollo stent for symptomatic atherosclerotic intracranial stenosis (SAIS). Forty-six patients (41 men and 5 women; median, 54 years of age) with forty-eight >or=50% SAISs were enrolled. Procedural feasibility was evaluated by stent success (residual stenosis or=24 months), which varied from 1 month to 30.7 months (median, 23.9 months). After 30 days, 1 patient (2.2%, 1/46) developed minor stroke in the target-lesion artery territory at 6.7 months. Primary end point rate was 4.3 per 100 patient years. Angiographic follow-up was performed in 25 patients. Seven restenoses (28%, 7/25) were detected, 1 of which was symptomatic. Angioplasty with the Apollo stent for symptomatic atherosclerotic intracranial stenosis is feasible. Severe tortuosity is an independent predictor of stent failure. Our clinical outcome seems to compare favorably with results of aspirin therapy, but the restenotic rate was high.

  5. Comparing the effectiveness and safety between triple antiplatelet therapy and dual antiplatelet therapy in type 2 diabetes mellitus patients after coronary stents implantation: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Bundhun, Pravesh Kumar; Qin, Tao; Chen, Meng-Hua

    2015-10-09

    Since antiplatelet therapy in type 2 diabetes mellitus (T2DM) patients is very important after intracoronary stenting, and because the most commonly used therapies have been the dual antiplatelet therapy (DAPT) consisting of aspirin and clopidogrel and the triple antiplatelet therapy (TAPT) consisting of aspirin, clopidogrel and cilostazol, we aim to compare the effectiveness and safety between triple antiplatelet therapy and dual antiplatelet therapy in T2DM patients. Systematic literature search was done from the databases of PubMed, Cochrane, Embase, China National Knowledge Infrastructure (CNKI) and WanFang. Randomized controlled trials (RCTs) comparing the effectiveness and safety between triple therapy and dual therapy in T2DM patients after coronary stents placement were included. Endpoints included major adverse cardiac effects (MACEs), target lesion revascularization (TLR), target vessel revascularization (TVR), death, stent thrombosis, bleeding and adverse drug reactions during a 9-12 months period, as well as platelet activities. Four studies including 1005 patients reporting the adverse clinical outcomes and six studies including 519 patients reporting the platelet activities, with a total of 1524 patients have been analyzed in this meta-analysis. The pooling analysis shows that TAPT has significantly decreased the occurrence of MACEs (RR: 0.55; 95 % CI: 0.36-0.86, P = 0.009), TLR (RR 0.41; 95 % CI: 0.21-0.80, P = 0.008), TVR (RR 0.55; 95 % CI: 0.34-0.88, P = 0.01) and the overall incidence of Death/ Myocardial Infarction (MI)/TVR (RR 0.54; 95 % CI: 0.31-0.94, P = 0.03) during this 9 to 12 months follow up period after stents implantation. Stent thrombosis was almost similar in both groups. Bleeding seemed to favor DAPT but the result was not statistically significant. Platelet aggregation, platelet reactivity index (PRI) and platelet reactivity unit (PRU) were also reduced with Weight Mean Difference (WMD) of (-13.80; 95 % CI: -17.03 to -10.56, P < 0.00001), (-22.87; 95 % CI: -23.66 to -22.07, P < 0.00001) and (-44.17; 95 % CI: -58.56 to -29.77, P < 0.00001) respectively. Since MACEs have been significantly decreased in the triple group, TAPT appears to be more effective than DAPT in T2DM patients after intracoronary stenting. No significant difference in stent thrombosis and bleeding risks between these 2 groups shows TAPT to be almost as safe as DAPT in these diabetic patients.

  6. Post-trial period surveillance for randomised controlled cardiovascular studies: submitted protocols, consent forms and the role of the ethics board.

    PubMed

    Zia, Mohammad I; Heslegrave, Ronald; Newton, Gary E

    2011-12-01

    The post-trial period is the time period after the end of study drug administration. It is unclear whether post-trial arrangements for patient surveillance are routinely included in study protocols and consents, and whether research ethics boards (REB) consider the post-trial period. The objective was to determine whether trial protocols and consent forms reviewed by the REB describe procedures for post-trial period surveillance. An observational study of protocols of randomised trials of chronic therapies for cardiac conditions, approved by the REB of two academic institutions affiliated with the University of Toronto in Canada (University Health Network and Mount Sinai Hospital) from 1995 to 2007. Plans for patient surveillance in the post-trial period described in the protocol or in the consent form before and after REB approval were recorded. 42 studies were identified including 18 heart failure and 15 coronary artery disease trials. Only four studies planned a clinical visit after trial termination, and an additional three planned a telephone contact after trial completion. Five trials submitted consent forms to the REB with a discussion of the post-trial period. The majority of protocols and consent forms did not discuss plans for post-trial period surveillance. The post-trial period and the REB approval process could be improved by systematic follow-up being described in the protocol and consent form. The small number of trial protocols evaluated in the study may impair the degree to which the results can be generalised.

  7. SPIRIT 2013 explanation and elaboration: guidance for protocols of clinical trials

    PubMed Central

    Tetzlaff, Jennifer M; Gøtzsche, Peter C; Altman, Douglas G; Mann, Howard; Berlin, Jesse A; Dickersin, Kay; Hróbjartsson, Asbjørn; Schulz, Kenneth F; Parulekar, Wendy R; Krleža-Jerić, Karmela; Laupacis, Andreas; Moher, David

    2013-01-01

    High quality protocols facilitate proper conduct, reporting, and external review of clinical trials. However, the completeness of trial protocols is often inadequate. To help improve the content and quality of protocols, an international group of stakeholders developed the SPIRIT 2013 Statement (Standard Protocol Items: Recommendations for Interventional Trials). The SPIRIT Statement provides guidance in the form of a checklist of recommended items to include in a clinical trial protocol. This SPIRIT 2013 Explanation and Elaboration paper provides important information to promote full understanding of the checklist recommendations. For each checklist item, we provide a rationale and detailed description; a model example from an actual protocol; and relevant references supporting its importance. We strongly recommend that this explanatory paper be used in conjunction with the SPIRIT Statement. A website of resources is also available (www.spirit-statement.org). The SPIRIT 2013 Explanation and Elaboration paper, together with the Statement, should help with the drafting of trial protocols. Complete documentation of key trial elements can facilitate transparency and protocol review for the benefit of all stakeholders. PMID:23303884

  8. SPIRIT 2013 explanation and elaboration: guidance for protocols of clinical trials.

    PubMed

    Chan, An-Wen; Tetzlaff, Jennifer M; Gøtzsche, Peter C; Altman, Douglas G; Mann, Howard; Berlin, Jesse A; Dickersin, Kay; Hróbjartsson, Asbjørn; Schulz, Kenneth F; Parulekar, Wendy R; Krleza-Jeric, Karmela; Laupacis, Andreas; Moher, David

    2013-01-08

    High quality protocols facilitate proper conduct, reporting, and external review of clinical trials. However, the completeness of trial protocols is often inadequate. To help improve the content and quality of protocols, an international group of stakeholders developed the SPIRIT 2013 Statement (Standard Protocol Items: Recommendations for Interventional Trials). The SPIRIT Statement provides guidance in the form of a checklist of recommended items to include in a clinical trial protocol. This SPIRIT 2013 Explanation and Elaboration paper provides important information to promote full understanding of the checklist recommendations. For each checklist item, we provide a rationale and detailed description; a model example from an actual protocol; and relevant references supporting its importance. We strongly recommend that this explanatory paper be used in conjunction with the SPIRIT Statement. A website of resources is also available (www.spirit-statement.org). The SPIRIT 2013 Explanation and Elaboration paper, together with the Statement, should help with the drafting of trial protocols. Complete documentation of key trial elements can facilitate transparency and protocol review for the benefit of all stakeholders.

  9. Design and rationale for a randomised comparison of everolimus-eluting stents and coronary artery bypass graft surgery in selected patients with left main coronary artery disease: the EXCEL trial.

    PubMed

    Kappetein, Arie Pieter; Serruys, Patrick W; Sabik, Joseph F; Leon, Martin B; Taggart, David P; Morice, Marie-Claude; Gersh, Bernard J; Pocock, Stuart J; Cohen, David J; Wallentin, Lars; Ben-Yehuda, Ori; van Es, Gerrit-Anne; Simonton, Charles A; Stone, Gregg W

    2016-09-18

    Coronary artery bypass graft (CABG) surgery is the standard of care for revascularisation of patients with left main coronary artery disease (LMCAD). Recent studies have suggested that percutaneous coronary intervention (PCI) with drug-eluting stents (DES) may provide comparable outcomes in selected patients with LMCAD without extensive CAD. We therefore designed a trial to investigate whether PCI with XIENCE cobalt-chromium everolimus-eluting stents (CoCr-EES) would result in non-inferior or superior clinical outcomes to CABG in selected patients with LMCAD. The Evaluation of XIENCE versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial is a prospective, open-label, multicentre, international study of 1,900 randomised subjects. Patients with significant LMCAD with a SYNTAX score ≤32 and local Heart Team consensus that the subject is appropriate for revascularisation by both PCI and CABG are consented and randomised 1:1 to undergo PCI using CoCr-EES or CABG. All patients undergo follow-up for five years. The primary endpoint is the three-year composite rate of death, stroke or myocardial infarction, assessed at a median follow-up of at least three years (with at least two-year follow-up in all patients), powered for sequential non-inferiority and superiority testing. The EXCEL study will define the contemporary roles of CABG and PCI using XIENCE CoCr-EES in patients with LMCAD disease with low and intermediate SYNTAX scores.

  10. Causes of Death Following PCI Versus CABG in Complex CAD: 5-Year Follow-Up of SYNTAX.

    PubMed

    Milojevic, Milan; Head, Stuart J; Parasca, Catalina A; Serruys, Patrick W; Mohr, Friedrich W; Morice, Marie-Claude; Mack, Michael J; Ståhle, Elisabeth; Feldman, Ted E; Dawkins, Keith D; Colombo, Antonio; Kappetein, A Pieter; Holmes, David R

    2016-01-05

    There are no data available on specific causes of death from randomized trials that have compared coronary artery bypass grafting (CABG) with percutaneous coronary intervention (PCI). The purpose of this study was to investigate specific causes of death, and its predictors, after revascularization for complex coronary disease in patients. An independent Clinical Events Committee consisting of expert physicians who were blinded to the study treatment subclassified causes of death as cardiovascular (cardiac and vascular), noncardiovascular, or undetermined according to the trial protocol. Cardiac deaths were classified as sudden cardiac, related to myocardial infarction (MI), and other cardiac deaths. In the randomized cohort, there were 97 deaths after CABG and 123 deaths after PCI during a 5-year follow-up. After CABG, 49.4% of deaths were cardiovascular, with the greatest cause being heart failure, arrhythmia, or other causes (24.6%), whereas after PCI, the majority of deaths were cardiovascular (67.5%) and as a result of MI (29.3%). The cumulative incidence rates of all-cause death were not significantly different between CABG and PCI (11.4% vs. 13.9%, respectively; p = 0.10), whereas there were significant differences in terms of cardiovascular (5.8% vs. 9.6%, respectively; p = 0.008) and cardiac death (5.3% vs. 9.0%, respectively; p = 0.003), which were caused primarily by a reduction in MI-related death with CABG compared with PCI (0.4% vs. 4.1%, respectively; p <0.0001). Treatment with PCI versus CABG was an independent predictor of cardiac death (hazard ratio: 1.55; 95% confidence interval: 1.09 to 2.33; p = 0.045). The difference in MI-related death was seen largely in patients with diabetes, 3-vessel disease, or high SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries) trial scores. During a 5-year follow-up, CABG in comparison with PCI was associated with a significantly reduced rate of MI-related death, which was the leading cause of death after PCI. Treatments following PCI should target reducing post-revascularization spontaneous MI. Furthermore, secondary preventive medication remains essential in reducing events post-revascularization. (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX]; NCT00114972). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials.

    PubMed

    Bundhun, Pravesh Kumar; Yanamala, Chandra Mouli; Huang, Wei-Qiang

    2017-03-16

    Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 - 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 - 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 - 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 - 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 - 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 - 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 - 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 - 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 - 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 - 1.82; P = 0.78 respectively. At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late definite or probable ST. However, further trials are recommended to assess the effects of these second-generation DES during the long-term.

  12. Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.

    PubMed

    Lee, Seung-Yul; Kim, Jung-Sun; Yoon, Hyuck-Jun; Hur, Seung-Ho; Lee, Sang-Gon; Kim, Jin Won; Hong, Young Joon; Kim, Ki-Seok; Choi, So-Yeon; Shin, Dong-Ho; Nam, Chung-Mo; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2018-02-09

    This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80). OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with favorable early strut coverage (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of The Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus-eluting Stents Versus Biolimus A9-eluting Stents [DETECT-OCT]; NCT01752894). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Assessing the detection, reporting and investigation of adverse events in clinical trial protocols implemented in Cameroon: a documentary review of clinical trial protocols.

    PubMed

    Ebile, Akoh Walter; Ateudjieu, Jerome; Yakum, Martin Ndinakie; Djuidje, Marceline Ngounoue; Watcho, Pierre

    2015-09-29

    International guidelines recommend ethical and scientific quality standards for managing and reporting adverse events occurring during clinical trials to competent research ethics committees and regulatory authorities. The purpose of this study was to determine whether clinical trial protocols in Cameroon are developed in line with national requirements and international guidelines as far as detecting, reporting and investigating of adverse events is concerned. It was a documentary review of all approved clinical trial protocols that were submitted at the Cameroon National Ethics Committee for evaluation from 1997 through 2012. Data were extracted using a preconceived and validated grid. Protocol review process targeted the title, abstract, objectives, methodology, resources, and the chapter on safety. In total, 106 (4.9 %) clinical trial protocols were identified from 2173 protocols seen in the archive and 104 (4.8 %) included for review. Seventy six (73.1 %) trials did not include the surveillance of adverse events as part of their objective. A total of 91 (87.5 %) protocols did not budget for adverse event surveillance, 76 (73.1 %) did not have a data safety management board (DSMB), 11(10.6 %) included insurance for participants, 47 (45.2 %) did not include a case definition for serious adverse events, 33 (31.7 %) described procedures to detect adverse events, 33 (31.7 %) described procedure for reporting and 22 (21.2 %) described procedure for investigating adverse events. Most clinical trial protocols in Cameroon are developed to focus on benefits and pay little attention to harms. The development of national guidelines can improve the surveillance of adverse events in clinical trial research conducted in Cameroon. Adverse events surveillance tools and a budget are critical for an adequate planning for adverse event surveillance when developing trial protocols. Clinical trial protocols submitted in the Cameroon National Ethics Committee do not adequately plan to assess adverse events in clinical trial protocols. In order to improve on the safety of participants and marketed drug, there is a need to develop national guidelines for clinical trials by the government, and to improve evaluation procedures and monitoring of ongoing trials by the ethics committee.

  14. The full metallic double-pigtail ureteral stent: Review of the clinical outcome and current status

    PubMed Central

    Kallidonis, Panagiotis S.; Georgiopoulos, Ioannis S.; Kyriazis, Iason D.; Kontogiannis, Stavros; Al-Aown, Abdulrahman M.; Liatsikos, Evangelos N.

    2015-01-01

    The full metallic double-J ureteral stent (MS) was introduced as a method for providing long-term drainage in malignant ureteral obstruction. Experimental evaluation of the MS revealed that its mechanical features allow efficient drainage in difficult cases, which could not be managed by the insertion of a standard polymeric double-J stent. Clinical experience with the MS showed controversial results. Careful patient selection results in efficient long-term management of malignant ureteral obstruction. The use of the MS should also be considered in selected benign cases. Major complications are uncommon and the minor complications should not hinder its use. Experience in pediatric patients is limited and warrants additional study. The cost-effectiveness of the MS seems to be appropriate for long-term treatment. Further investigation with comparative clinical trials would document the outcome more extensively and establish the indications as well as the selection criteria for the MS. PMID:25624569

  15. Carotid Artery Stenting, Endarterectomy, or Medical Treatment Alone: The Debate Is Not Over

    PubMed Central

    Kassaian, Seyed Ebrahim; Goodarzynejad, Hamidreza

    2011-01-01

    The management of carotid artery stenosis reduces the risk of stroke and its related deaths. Management options include risk factor modification and medical therapy, carotid endarterectomy (CEA), and carotid artery stenting (CAS). Although several randomized controlled trials (RCTs), mostly conducted in late-1980s and mid-1990s, have proved CEA to be effective in the prevention of ipsilateral ischemic events in selected patients with carotid artery stenosis, aggressive risk factor modification and medical therapy with recently introduced antiplatelet agents, statins, and more effective antihypertensive medications may have reduced compelling indications for immediate surgery in asymptomatic populations. Also recently, due to improvements in percutaneous techniques and carotid stents, CAS has received wide attention as a potential alternative to CEA. Herein, we review the recent data on the management options of carotid artery stenosis and seek to identify the most appropriate treatment strategy in selected patients with carotid artery stenosis. PMID:23074598

  16. Randomised comparison of drug-eluting versus bare-metal stenting in patients with non-ST elevation myocardial infarction.

    PubMed

    Remkes, Wouter S; Badings, Erik A; Hermanides, Renicus S; Rasoul, Saman; Dambrink, Jan-Henk E; Koopmans, Petra C; The, Salem Hk; Ottervanger, Jan Paul; Gosselink, A T Marcel; Hoorntje, Jan Ca; Suryapranata, Harry; van 't Hof, Arnoud Wj

    2016-01-01

    The superiority of drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ST elevation myocardial infarction (STEMI) is well studied; however, randomised data in patients with non-ST elevation myocardial infarction (NSTEMI) are lacking. The objective of this study was to investigate whether stenting with everolimus-eluting stents (EES) safely reduces restenosis in patients with NSTEMI as compared to BMS. ELISA-3 patients were asked to participate in the angiographic substudy and were randomised to DE (Xience V) or BM (Vision) stenting (ELISA-3 group). The primary end point was minimal luminal diameter (MLD) at 9-month follow-up angiography. In addition, 296 patients with NSTEMI who were excluded or did not want to participate in the ELISA-3 trial (RELI group) were randomised to DE or BM stenting and underwent clinical follow-up only (major adverse cardiac events (MACE), stent thrombosis (ST)). A pooled analysis was performed to assess an effect on clinical outcome. 178 of 540 ELISA-3 patients participated in the angiographic substudy. MLD at 9 months angiography was 2.37±0.63 mm (DES) versus 1.84±0.62 mm (BMS), p<0.001. Binary restenosis occurred in 1.9% in the DES group versus 16.7% in the BMS group (RR 0.11, 95% CI 0.02 to 0.84, p=0.007). In the pooled analysis, the incidence of MACE, target vessel revascularisation and ST at 2 years follow-up in the DES versus BMS group was 12.5% versus 16.0% (p=0.28), 4.0% versus 10.4% (p=0.009) and 1.3% versus 3.0% (p=0.34), respectively. In patients with NSTEMI, use of EES is safe and decreases both angiographic and clinical restenosis as compared to BMS http://www.isrctn.com/search?q=39230163. 39230163; Post-results.

  17. Low-profile stent placement with the monorail technique for treatment of renal artery stenosis: midterm results of a prospective trial.

    PubMed

    Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas

    2005-07-01

    To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.

  18. Fifty shades of gradients: does the pressure gradient in venous sinus stenting for idiopathic intracranial hypertension matter? A systematic review.

    PubMed

    McDougall, Cameron M; Ban, Vin Shen; Beecher, Jeffrey; Pride, Lee; Welch, Babu G

    2018-03-02

    OBJECTIVE The role of venous sinus stenting (VSS) for idiopathic intracranial hypertension (IIH) is not well understood. The aim of this systematic review is to attempt to identify subsets of patients with IIH who will benefit from VSS based on the pressure gradients of their venous sinus stenosis. METHODS MEDLINE/PubMed was searched for studies reporting venous pressure gradients across the stenotic segment of the venous sinus, pre- and post-stent pressure gradients, and clinical outcomes after VSS. Findings are reported according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. RESULTS From 32 eligible studies, a total of 186 patients were included in the analysis. Patients who had favorable outcomes had higher mean pressure gradients (22.8 ± 11.5 mm Hg vs 17.4 ± 8.0 mm Hg, p = 0.033) and higher changes in pressure gradients after stent placement (19.4 ± 10.0 mm Hg vs 12.0 ± 6.0 mm Hg, p = 0.006) compared with those with unfavorable outcomes. The post-stent pressure gradients between the 2 groups were not significantly different (2.8 ± 4.0 mm Hg vs 2.7 ± 2.0 mm Hg, p = 0.934). In a multivariate stepwise logistic regression controlling for age, sex, body mass index, CSF opening pressure, pre-stent pressure gradient, and post-stent pressure gradient, the change in pressure gradient with stent placement was found to be an independent predictor of favorable outcome (p = 0.028). Using a pressure gradient of 21 as a cutoff, 81/86 (94.2%) of patients with a gradient > 21 achieved favorable outcomes, compared with 82/100 (82.0%) of patients with a gradient ≤ 21 (p = 0.022). CONCLUSIONS There appears to be a relationship between the pressure gradient of venous sinus stenosis and the success of VSS in IIH. A randomized controlled trial would help elucidate this relationship and potentially guide patient selection.

  19. Reduced duration of dual antiplatelet therapy using an improved drug-eluting stent for percutaneous coronary intervention of the left main artery in a real-world, all-comer population: Rationale and study design of the prospective randomized multicenter IDEAL-LM trial.

    PubMed

    Lemmert, Miguel E; Oldroyd, Keith; Barragan, Paul; Lesiak, Maciej; Byrne, Robert A; Merkulov, Evgeny; Daemen, Joost; Onuma, Yoshinobu; Witberg, Karen; van Geuns, Robert-Jan

    2017-05-01

    Continuous improvements in stent technology make percutaneous coronary intervention (PCI) a potential alternative to surgery in selected patients with unprotected left main coronary artery (uLMCA) disease. The optimal duration of dual antiplatelet therapy (DAPT) in these patients remains undetermined, and in addition, new stent designs using a bioabsorbable polymer might allow shorter duration of DAPT. IDEAL-LM is a prospective, randomized, multicenter study that will enroll 818 patients undergoing uLMCA PCI. Patients will be randomized in a 1:1 fashion to intravascular ultrasound-guided PCI with the novel everolimus-eluting platinum-chromium Synergy stent with a biodegradable polymer (Boston Scientific, Natick, MA) followed by 4 months of DAPT or the everolimus-eluting cobalt-chromium Xience stent (Abbott Vascular, Santa Clara, CA) followed by 12 months of DAPT. The total follow-up period will be 5 years. A subset of 100 patients will undergo optical coherence tomography at 3 months. The primary end point will be major adverse cardiovascular events (composite of all-cause mortality, myocardial infarction, and ischemia-driven target vessel revascularization) at 2 years. Secondary end points will consist of the individual components of the primary end point, procedural success, a device-oriented composite end point, stent thrombosis as per Academic Research Consortium criteria, and bleeding as per Bleeding Academic Research Consortium criteria. IDEAL-LM is designed to assess the safety and efficacy of the novel Synergy stent followed by 4 months of DAPT vs the Xience stent followed by 12 months of DAPT in patients undergoing uLMCA PCI. The study will provide novel insights regarding optimal treatment strategy for patients undergoing PCI of uLMCA disease (www.clinicaltrials.gov, NCT 02303717). Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  20. Systematic Evaluation of the Patient-Reported Outcome (PRO) Content of Clinical Trial Protocols

    PubMed Central

    Kyte, Derek; Duffy, Helen; Fletcher, Benjamin; Gheorghe, Adrian; Mercieca-Bebber, Rebecca; King, Madeleine; Draper, Heather; Ives, Jonathan; Brundage, Michael; Blazeby, Jane; Calvert, Melanie

    2014-01-01

    Background Qualitative evidence suggests patient-reported outcome (PRO) information is frequently absent from clinical trial protocols, potentially leading to inconsistent PRO data collection and risking bias. Direct evidence regarding PRO trial protocol content is lacking. The aim of this study was to systematically evaluate the PRO-specific content of UK National Institute for Health Research (NIHR) Health Technology Assessment (HTA) programme trial protocols. Methods and Findings We conducted an electronic search of the NIHR HTA programme database (inception to August 2013) for protocols describing a randomised controlled trial including a primary/secondary PRO. Two investigators independently reviewed the content of each protocol, using a specially constructed PRO-specific protocol checklist, alongside the ‘Standard Protocol Items: Recommendations for Interventional Trials’ (SPIRIT) checklist. Disagreements were resolved through discussion with a third investigator. 75 trial protocols were included in the analysis. Protocols included a mean of 32/51 (63%) SPIRIT recommendations (range 16–41, SD 5.62) and 11/33 (33%) PRO-specific items (range 4–18, SD 3.56). Over half (61%) of the PRO items were incomplete. Protocols containing a primary PRO included slightly more PRO checklist items (mean 14/33 (43%)). PRO protocol content was not associated with general protocol completeness; thus, protocols judged as relatively ‘complete’ using SPIRIT were still likely to have omitted a large proportion of PRO checklist items. Conclusions The PRO components of HTA clinical trial protocols require improvement. Information on the PRO rationale/hypothesis, data collection methods, training and management was often absent. This low compliance is unsurprising; evidence shows existing PRO guidance for protocol developers remains difficult to access and lacks consistency. Study findings suggest there are a number of PRO protocol checklist items that are not fully addressed by the current SPIRIT statement. We therefore advocate the development of consensus-based supplementary guidelines, aimed at improving the completeness and quality of PRO content in clinical trial protocols. PMID:25333349

  1. Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Zhongmin, E-mail: wzm0722@hotmail.co; Chen Kemin, E-mail: ckm0722@hotmail.co; Gong Ju

    Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival timemore » between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.« less

  2. Hybrid coronary revascularization in the era of drug-eluting stents.

    PubMed

    Murphy, Gavin J; Bryan, Alan J; Angelini, Gianni D

    2004-11-01

    Left internal mammary artery to left anterior descending coronary artery bypass grafting integrated with percutaneous coronary angioplasty (hybrid procedure) offers multivessel revascularization with minimal morbidity in high-risk patients. This is caused in part by the avoidance of cardiopulmonary bypass-related morbidity and manipulation of the aorta coupled with minimally invasive techniques. Hybrid revascularization is currently reserved for particularly high-risk patients or those with favorable anatomic variants however, largely because of the emergence of off-pump coronary artery bypass grafting, which permits more complete multivessel revascularization, with low morbidity in high-risk groups. The wider introduction of hybrid revascularization is limited chiefly by the high number of repeat interventions compared with off-pump coronary artery bypass grafting, which occurs because of the target vessel failure rate of percutaneous coronary intervention. Other demerits are the costs and logistic problems associated with performing two procedures with differing periprocedural management protocols. Recently, drug-eluting stents have reduced the need for repeat intervention after percutaneous coronary intervention, and this has raised the possibility that the results of hybrid revascularization may now equal or even better those of off-pump coronary artery bypass grafting. Although undoubtedly effective at reducing in-stent restenosis, drug-eluting stents will not address the issues of incomplete revascularization or the logistic problems associated with hybrid. Uncertainty regarding the long-term effectiveness of drug-eluting stents in many patients, as well as their high cost when compared with those of off-pump coronary artery bypass grafting surgery, also militates against the wider introduction of hybrid revascularization.

  3. Real-World Multicenter Registry of Patients with Severe Coronary Artery Calcification Undergoing Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard

    2016-08-01

    We evaluated the safety and efficacy of orbital atherectomy in real-world patients with severe coronary artery calcification (CAC). The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30-day all-cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no-reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. In the largest real-world study of patients who underwent orbital atherectomy, including high-risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short-term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. © 2016 The Authors. Journal of Interventional Cardiology Published by Wiley Periodicals, Inc.

  4. Randomized comparison of cost-saving and effectiveness of oral rapamycin plus bare-metal stents with drug-eluting stents: three-year outcome from the randomized oral rapamycin in Argentina (ORAR) III trial.

    PubMed

    Rodriguez, Alfredo E; Rodriguez-Granillo, Alfredo M; Antoniucci, David; Mieres, Juan; Fernandez-Pereira, Carlos; Rodriguez-Granillo, Gaston A; Santaera, Omar; Rubilar, Bibiana; Palacios, Igor F; Serruys, Patrick W

    2012-09-01

    The Oral Rapamycin in ARgentina (ORAR) III trial is a randomized study comparing a strategy of oral rapamycin (OR) plus bare-metal stent (BMS) versus a strategy of drug-eluting stents (DES) in patients with de novo coronary lesions. The purpose of this study was to assess the 3 years cost-effectiveness outcome of each strategy. OR after BMS has been associated with reduction of target vessel revascularization (TVR) although its value in long-term efficacy in comparison with DES is unknown. In three hospitals in Buenos Aires, Argentina, 200 patients were randomized to OR plus BMS (n = 100) or DES (n = 100). Primary objectives were costs and effectiveness. Cost analysis included in-hospital and follow-up costs. Safety was defined as the composite of death, myocardial infarction (MI), and stroke. Efficacy was defined as TVR. Baseline characteristics between groups were similar. The 3-year follow-up rate was 99%. Cardiac mortality was 2% and 5% in OR group and DES group, respectively (P = 0.44). The composite of death, MI and stroke rate was 11% in OR group and 20% in DES group (P = 0.078). TVR rate was 14.5% in OR group and 17.6% in DES group (P = 0.50), respectively. Three year cumulative costs were significantly lower in the OR arm as compared to the DES arm (P = 0.0001) and DES strategy did not result cost-effective according to the non-inferiority test. At 3 years follow-up, there were no differences in effectiveness between the two strategies, and DES strategy was not more cost-effective as compared to OR plus BMS. Copyright © 2011 Wiley Periodicals, Inc.

  5. [Stents in dialysis vascular access--do they promise improved high quality prolonged access use].

    PubMed

    Klein, Osnat; Plotkin, Eleonora; Gritun, Igal; Verner, Myriam; Lehmann, J M; Rathaus, Mauro; Bernheim, Jacques

    2008-02-01

    The life expectancy of dialysis patients depends, to a large extent, on blood access which provides uninterrupted and efficient treatment. Dialysis access created by a direct anastomosis between artery and vein usually allows normal dialysis for many years. Blood access by a bridge graft between artery and vein functions for a much shorter time and occludes chiefly because of endothelial hyperplasia at the graft vein anastomosis. This type of fistula is created when the veins of the patient are small. During the last few years the dialysis population is increasingly composed of adult and elderly patients suffering from diabetes mellitus, hypertension, dyslipidemias and atheromatous vascular disease so that a relatively large proportion of dialysis accesses are created using a bridge graft. Since we currently do not have the knowledge of how to arrest or delay the processes which lead to access occlusion, attempts are made to implement prophylactic strategies, find stenoses and dilate them before the access fails. Up to date, controlled trials have not succeeded in proving that this method prolongs access use. These trials did not describe the use of stents following dilatation. Between July 2002 and May 2005, 238 angiographies were performed on blood accesses including 179 angioplasties of stenoses. In sixteen patients a stent was deployed during the angioplasty. In ten patients dialysis was performed using the same access up to the end of the study period, an average of 43 months from the creation of the access. Three patients died with a functioning access and in three the access occluded during the period of followup. This study shows that the use of stents following angioplasty of dialysis access stenoses can improve the duration of use of accesses created through grafts.

  6. Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.

    PubMed

    McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E

    2011-12-01

    Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (P<0.001), whereas TPV compression (P=0.01) and apposition to the anterior chest wall (P=0.02) were associated with shorter freedom from MSF. Freedom from RVOT reintervention was 86±4% at 27 months. Among patients with a MSF, freedom from RVOT reintervention after MSF diagnosis was 49±10% at 2 years. Factors associated with reintervention were similar to those for MSF. MSF was common after TPV implant in this multicenter experience and was more likely in patients with severely obstructed RVOT conduits and when the TPV was directly behind the anterior chest wall and/or clearly compressed. A TPV implant site protected by a prestent or bioprosthetic valve was associated with lower risk of MSF and reintervention.

  7. Optical Coherence Tomography Substudy of A Prospective Multicenter Randomized Post-Market Trial to Assess the Safety and Effectiveness of the Firehawk™ Rapamycin Target Eluting Cobalt Chromium Coronary Stent System for the Treatment of Atherosclerotic Lesions: TARGET All Comers.

    PubMed

    Baumbach, Andreas; Lansky, Alexandra J; Onuma, Yoshi; Asano, Taku; Johnson, Thomas; Anderson, Richard; Kiemeneij, Ferdinand; Zheng, Ming; Van Royen, Niels; Slagboom, Ton; Vlachojannis, Georg; Xu, Bo; Serruys, Patrick; Wijns, William

    2018-06-12

    Durable polymer drug-eluting stents (DP DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this Optical Coherence Tomography (OCT) sub-study was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (FIREHAWK®) (BP DES) versus the DP DES (XIENCE) at 90 days in an all comers patient population. The TARGET All Comers study is a prospective multicenter randomised post-market trial of 1656 patients randomised 1:1 to FIREHAWK or XIENCE at 21 centers in 10 European countries. The TARGET OCT sub-study enrolled 36 consecutive patients with 52 lesions at 6 centers proficient in OCT. Follow-up OCT was performed at 3 months or prior to revascularisation when occurring before the 3-month window. The substudy was designed for non-inferiority of the primary endpoint of neointimal thickness. At follow-up, the mean neointimal thickness by OCT (52 lesions, Firehawk, n=24; Xience, n=28), was not significantly different between groups (Firehawk 75.5μm vs Xience V 82.3 μm) meeting the primary endpoint of non-inferiority (Pnoninferiority<0.001). The percentage of stent strut coverage was high in both groups (strut level: 99.9% ± 0.3 vs 100% ± 0.1, p=0.26), and the proportion of malapposed struts (1.0±1.6% vs. 1.2±2.0%, p=0.51) was low in both groups. Based on OCT, the FIREHAWK BP DES has a similar healing response 3 months after implantation compared to the DP DES, with near complete strut coverage, moderate neointima formation and minimal strut malapposition.

  8. Detailed Analysis of Peri-Procedural Strokes in Patients Undergoing Intracranial Stenting in SAMMPRIS

    PubMed Central

    Fiorella, David; Derdeyn, Colin P; Lynn, Michael J; Barnwell, Stanley L; Hoh, Brian L.; Levy, Elad I.; Harrigan, Mark R.; Klucznik, Richard P.; McDougall, Cameron G.; Pride, G. Lee; Zaidat, Osama O.; Lutsep, Helmi L.; Waters, Michael F.; Hourihane, J. Maurice; Alexandrov, Andrei V.; Chiu, David; Clark, Joni M.; Johnson, Mark D.; Torbey, Michel T.; Rumboldt, Zoran; Cloft, Harry J.; Turan, Tanya N.; Lane, Bethany F.; Janis, L. Scott; Chimowitz, Marc I.

    2012-01-01

    Background and Purpose Enrollment in the SAMMPRIS trial was halted due to the high risk of stroke or death within 30 days of enrollment in the percutaneous transluminal angioplasty and stenting (PTAS) arm relative to the medical arm. This analysis focuses on the patient and procedural factors that may have been associated with peri-procedural cerebrovascular events in the trial. Methods Bivariate and multivariate analyses were performed to evaluate whether patient and procedural variables were associated with cerebral ischemic or hemorrhagic events occurring within 30 days of enrollment (termed peri-procedural) in the PTAS arm. Results Of 224 patients randomized to PTAS, 213 underwent angioplasty alone (n=5) or with stenting (n=208). Of these, 13 had hemorrhagic strokes (7 parenchymal, 6 subarachnoid), 19 had ischemic stroke, and 2 had cerebral infarcts with temporary signs (CITS) within the peri-procedural period. Ischemic events were categorized as perforator occlusions (13), embolic (4), mixed perforator and embolic (2), and delayed stent occlusion (2). Multivariate analyses showed that higher percent stenosis, lower modified Rankin score, and clopidogrel load associated with an activated clotting time above the target range were associated (p ≤ 0.05) with hemorrhagic stroke. Non-smoking, basilar artery stenosis, diabetes, and older age were associated (p ≤ 0.05) with ischemic events. Conclusions Peri-procedural strokes in SAMMPRIS had multiple causes with the most common being perforator occlusion. Although risk factors for peri-procedural strokes could be identified, excluding patients with these features from undergoing PTAS to lower the procedural risk would limit PTAS to a small subset of patients. Moreover, given the small number of events, the present data should be used for hypothesis generation rather than to guide patient selection in clinical practice. PMID:22984008

  9. The benefit of silicone stents in primary endonasal dacryocystorhinostomy: a systematic review and meta-analysis.

    PubMed

    Sarode, D; Bari, D A; Cain, A C; Syed, M I; Williams, A T

    2017-04-01

    To critically evaluate the evidence comparing success rates of endonasal dacryocystorhinostomy (EN-DCR) with and without silicone tubing and to thus determine whether silicone intubation is beneficial in primary EN-DCR. Systematic review and meta-analysis. A literature search was performed on AMED, EMBASE, HMIC, MEDLINE, PsycINFO, BNI, CINAHL, HEALTH BUSINESS ELITE, CENTRAL and Cochrane Ear, Nose and Throat disorders groups trials register using a combination of various MeSH. The date of last search was January 2016. This review was limited to randomised controlled trials (RCTs) in English language. Risk of bias was assessed using the Cochrane Collaboration's risk of bias tool. Chi-square and I 2 statistics were calculated to determine the presence and extent of statistical heterogeneity. Study selection, data extraction and risk of bias scoring were performed independently by two authors in concordance with the PRISMA statement. Five RCTs (447 primary EN-DCR procedures in 426 patients) were included for analysis. Moderate interstudy statistical heterogeneity was demonstrated (Chi 2 = 6.18; d.f. = 4; I 2 = 35%). Bicanalicular silicone stents were used in 229 and not used in 218 procedures. The overall success rate of EN-DCR was 92.8% (415/447). The success rate of EN-DCR was 93.4% (214/229) with silicone tubing and 92.2% (201/218) without silicone tubing. Meta-analysis using a random-effects model showed no statistically significant difference in outcomes between the two groups (P = 0.63; RR = 0.79; 95% CI = 0.3-2.06). Our review and meta-analysis did not demonstrate an additional advantage of silicone stenting. A high-quality well-powered prospective multicentre RCT is needed to further clarify on the benefit of silicone stents. © 2016 John Wiley & Sons Ltd.

  10. Comparison of orbital atherectomy plus balloon angioplasty vs. balloon angioplasty alone in patients with critical limb ischemia: results of the CALCIUM 360 randomized pilot trial.

    PubMed

    Shammas, Nicolas W; Lam, Russell; Mustapha, Jihad; Ellichman, Jonathan; Aggarwala, Gaurav; Rivera, Ernesto; Niazi, Khusrow; Balar, Nilesh

    2012-08-01

    To evaluate the role of orbital atherectomy in calcified infrapopliteal arteries in patients with critical limb ischemia compared to balloon angioplasty (BA) alone. A randomized multicenter study was undertaken to evaluate short and 1-year outcomes in 50 patients (32 men; mean age 71 years, range 40-90) with confirmed calcified lesions using 1∶1 randomization to the Diamondback 360° Orbital Atherectomy System followed by BA vs. BA alone. All patients had severe (≥50% stenosis) peripheral artery disease (Rutherford classification 4-6) in the popliteal, tibial, and/or peroneal arteries. The primary endpoint was defined as restoration of a normal lumen (residual stenosis ≤30%) with no bailout stenting or dissection types C through F. Scheduled follow-up visits were conducted according to a common protocol at 1, 6, and 12 months. Procedural success was 93.1% (27/29 lesions) for atherectomy + BA patients and 82.4% (28/34 lesions) for BA alone (p = 0.27). Bailout stenting was needed in 2 (6.9%) of the 29 atherectomy + BA lesions and in 5 (14.3%) of the 35 BA-treated lesions (p = 0.44). At 1 year, there were no amputations in either group related to the index procedure. Estimates for freedom from target vessel revascularization and all-cause mortality were 93.3% and 100% in the atherectomy + BA group vs. 80.0% (p = 0.14) and 68.4% (p = 0.01) in the BA group, respectively. Proportional hazard models evaluating survival time vs. status of residual stenosis determined a hazard ratio for major adverse events of 5.6 for patients with an acute post-procedure residual stenosis >30% (p = 0.01). Debulking with orbital atherectomy appeared to increase the chance of reaching a desirable angioplasty result, with less acute need for bailout stenting and a higher procedure success. A negative association between procedure success and risk of serious adverse outcomes should encourage larger confirmatory studies.

  11. Intra-operative cone beam computed tomography can help avoid reinterventions and reduce CT follow up after infrarenal EVAR.

    PubMed

    Törnqvist, P; Dias, N; Sonesson, B; Kristmundsson, T; Resch, T

    2015-04-01

    Re-interventions after endovascular abdominal aortic aneurysm repair (EVAR) are common and therefore a strict imaging follow up protocol is required. The purpose of this study was to evaluate whether cone beam computed tomography (CBCT) can detect intra-operative complications and to compare this with angiography and the 1 month CT follow up (computed tomography angiography [CTA]). Fifty-one patients (44 men) were enrolled in a prospective trial. Patients underwent completion angiography and CBCT during infrarenal EVAR. Contrast was used except when pre-operative renal insufficiency was present or if the maximum contrast dose threshold was reached. CBCT reconstruction included the top of the stent graft to the iliac bifurcation. Endoleaks, kinks, or compressions were recorded. CBCT was technically successful in all patients. Twelve endoleaks were detected on completion digital subtraction angiography (CA). CBCT detected 4/5 type 1 endoleaks, but only one type 2 endoleak. CTA identified eight type 2 endoleaks and one residual type I endoleak. Two cases of stent compression were seen on CA. CBCT revealed five stent compressions and one kink, which resulted in four intra-operative adjunctive manoeuvres. CTA identified all cases of kinks or compressions that were left untreated. Two of them were corrected later. No additional kinks/compressions were found on CTA. Groin closure consisted of 78 fascia sutures, nine cut downs, and 11 percutaneous sutures. Seven femoral artery pseudoaneurysms (<1 cm) were detected on CTA, but no intervention was needed. CA is better than CBCT in detecting and categorizing endoleaks but CBCT (with or without contrast) is better than CA for detection of kinks or stentgraft compression. CTA plus CBCT identified all significant complications noted on the 1 month follow up CTA. The use of intra-operative CA and CBCT could replace early CTA after standard EVAR thus reducing overall radiation and contrast use. Technical development might further improve the resolution and usefulness of CBCT. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Subgroup analyses in randomised controlled trials: cohort study on trial protocols and journal publications.

    PubMed

    Kasenda, Benjamin; Schandelmaier, Stefan; Sun, Xin; von Elm, Erik; You, John; Blümle, Anette; Tomonaga, Yuki; Saccilotto, Ramon; Amstutz, Alain; Bengough, Theresa; Meerpohl, Joerg J; Stegert, Mihaela; Olu, Kelechi K; Tikkinen, Kari A O; Neumann, Ignacio; Carrasco-Labra, Alonso; Faulhaber, Markus; Mulla, Sohail M; Mertz, Dominik; Akl, Elie A; Bassler, Dirk; Busse, Jason W; Ferreira-González, Ignacio; Lamontagne, Francois; Nordmann, Alain; Gloy, Viktoria; Raatz, Heike; Moja, Lorenzo; Rosenthal, Rachel; Ebrahim, Shanil; Vandvik, Per O; Johnston, Bradley C; Walter, Martin A; Burnand, Bernard; Schwenkglenks, Matthias; Hemkens, Lars G; Bucher, Heiner C; Guyatt, Gordon H; Briel, Matthias

    2014-07-16

    To investigate the planning of subgroup analyses in protocols of randomised controlled trials and the agreement with corresponding full journal publications. Cohort of protocols of randomised controlled trial and subsequent full journal publications. Six research ethics committees in Switzerland, Germany, and Canada. 894 protocols of randomised controlled trial involving patients approved by participating research ethics committees between 2000 and 2003 and 515 subsequent full journal publications. Of 894 protocols of randomised controlled trials, 252 (28.2%) included one or more planned subgroup analyses. Of those, 17 (6.7%) provided a clear hypothesis for at least one subgroup analysis, 10 (4.0%) anticipated the direction of a subgroup effect, and 87 (34.5%) planned a statistical test for interaction. Industry sponsored trials more often planned subgroup analyses compared with investigator sponsored trials (195/551 (35.4%) v 57/343 (16.6%), P<0.001). Of 515 identified journal publications, 246 (47.8%) reported at least one subgroup analysis. In 81 (32.9%) of the 246 publications reporting subgroup analyses, authors stated that subgroup analyses were prespecified, but this was not supported by 28 (34.6%) corresponding protocols. In 86 publications, authors claimed a subgroup effect, but only 36 (41.9%) corresponding protocols reported a planned subgroup analysis. Subgroup analyses are insufficiently described in the protocols of randomised controlled trials submitted to research ethics committees, and investigators rarely specify the anticipated direction of subgroup effects. More than one third of statements in publications of randomised controlled trials about subgroup prespecification had no documentation in the corresponding protocols. Definitive judgments regarding credibility of claimed subgroup effects are not possible without access to protocols and analysis plans of randomised controlled trials. © The DISCO study group 2014.

  13. Design considerations and quantitative assessment for the development of percutaneous mitral valve stent.

    PubMed

    Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt

    2014-07-01

    Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral regurgitation, by virtue of their key features as well as effective crimping. These models will be fabricated and put to all the aforementioned tests before being taken for animal trials. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. One swallow does not a summer make but many swallows do: accumulating clinical evidence for nearly-eliminated peri-procedural and 30-day complications with mesh-covered stents transforms the carotid revascularisation field

    PubMed Central

    Hopkins, L. Nelson; Siddiqui, Adnan H.

    2017-01-01

    Atherosclerotic carotid artery stenosis (CS) continues to be a common cause of acute ischaemic stroke. Optimised medical therapy (OMT), the first-line treatment modality in CS, may reduce or delay – but it does not abolish – CS-related strokes. As per current AHA/ASA and ESC/ESVS/ESO guidelines, carotid artery stenting (CAS) is a less-invasive alternative to carotid endarterectomy (CEA) for CS revascularisation in primary and secondary stroke prevention. Ten-year follow-up from the CREST trial in patients with symptomatic and asymptomatic CS confirmed equipoise of CAS and CEA in the primary endpoint. Nevertheless CAS – using a widely open-cell, first-generation stent and first-generation (distal/filter) neuroprotection – has been criticised for its relative excess of (mostly minor) strokes by 30 days, a significant proportion of which were post-procedural. Atherosclerotic plaque protrusion through conventional carotid stent struts, confirmed on intravascular imaging, has been implicated as a leading mechanism of the relative excess of strokes with CAS vs. CEA, including delayed strokes with CAS. Different designs of mesh-covered carotid stents have been developed to prevent plaque prolapse. Several multi-centre/multi-specialty clinical studies with CGurad MicroNet-Covered Embolic Prevention Stent System (EPS) and RoadSaver/Casper were recently published and included routine DW-MRI cerebral imaging peri-procedurally and at 30 days (CGuard EPS). Data from more than 550 patients in mesh-covered carotid stent clinical studies to-date show an overall 30-day complication rate of ~1% with near-elimination of post-procedural events. While more (and long-term) evidence is still anticipated, these results – taken together with optimised intra-procedural neuroprotection in CAS (increased use of proximal systems including trans-carotid dynamic flow reversal) and the positive 12-month mesh-covered stent data reports in 2017 – are transforming the carotid revascularisation field today. Establishing effective algorithms to identify the asymptomatic subjects at stroke risk despite OMT, and large-scale studies with mesh-covered stents including long-term clinical and duplex ultrasound outcomes, are the next major goals. PMID:28798779

  15. Comparison of ADM and Connective Tissue Graft as the Membrane in Class II Furcation Defect Regeneration: A Randomized Clinical Trial

    PubMed Central

    Esfahanian, Vahid; Farhad, Shirin; Sadighi Shamami, Mehrnaz

    2014-01-01

    Background and aims. Furcally-involved teeth present unique challenges to the success of periodontal therapy and influence treatment outcomes. This study aimed to assess to compare use of ADM and connective tissue membrane in class II furcation defect regeneration. Materials and methods. 10 patient with 2 bilaterally class II furcation defects in first and/or second maxilla or man-dibular molar without interproximal furcation involvement, were selected. Four weeks after initial phase of treatment, before and thorough the surgery pocket depth (PD), clinical attachment level to stent (CAL-S), free gingival margin to stent(FGM-S) , crestal bone to stent (Crest-S), horizontal defect depth to stent (HDD-S) and vertical defect depth to stent (VDD-S) and crestal bone to defect depth measured from stent margin. Thereafter, one side randomly treated using connective tissue and DFDBA (study group) and opposite side received ADM and DFDBA (control group). After 6 months, soft and hard tissue parameters measured again in re-entry. Results. Both groups presented improvements after therapies (P & 0.05). No inter-group differences were seen in PD re-duction (P = 0.275), CAL gain (P = 0.156), free gingival margin (P = 0.146), crest of the bone (P = 0.248), reduction in horizontal defects depth (P = 0.139) and reduction in vertical defects depth (P = 0.149). Conclusion. Both treatments modalities have potential of regeneration without any adverse effect on healing process. Connective tissue grafts did not have significant higher bone fill compared to that of ADM. PMID:25093054

  16. Endoscopic Stenting as Bridge to Surgery versus Emergency Resection for Left-Sided Malignant Colorectal Obstruction: An Updated Meta-Analysis

    PubMed Central

    Ceresoli, Marco; Fugazzola, Paola; Ansaloni, Luca

    2017-01-01

    Introduction Emergency resection represents the traditional treatment for left-sided malignant obstruction. However, the placement of self-expanding metallic stents and delayed surgery has been proposed as an alternative approach. The aim of the current meta-analysis was to review the available evidence, with particular interest for the short-term outcomes, including a recent multicentre RCT. Methods We considered randomized controlled trials comparing stenting as a bridge to surgery and emergency surgery for the management of left-sided malignant large bowel obstruction, performing a systematic review in MEDLINE, PubMed database, and the Cochrane libraries. Results We initially identified a total of 2543 studies. After the elimination of duplicates and the screening of titles and abstracts, seven studies, for a total of 448 patients, were considered. The current meta-analysis revealed no difference in the mortality rate between the stent group and the emergency surgery group; the postoperative complication rate (37.84% versus 54.87%, P = 0.02), the stoma rate (28.8% versus 46.02%, P < 0.0001), and the incidence of wound infection (8.11% versus 15.49%, P = 0.01) were reduced after stent as a bridge to surgery. Conclusion Colonic stenting as a bridge to surgery appears to be a safe approach to malignant large bowel obstruction. Possible advantages of this treatment can be identified in a reduced incidence of postoperative complications and a lower stoma rate. Further RCTs considering long-term outcomes and cost-effectiveness analysis are needed. PMID:28761765

  17. Management of pancreatic fluid collections: A comprehensive review of the literature

    PubMed Central

    Tyberg, Amy; Karia, Kunal; Gabr, Moamen; Desai, Amit; Doshi, Rushabh; Gaidhane, Monica; Sharaiha, Reem Z; Kahaleh, Michel

    2016-01-01

    Pancreatic fluid collections (PFCs) are a frequent complication of pancreatitis. It is important to classify PFCs to guide management. The revised Atlanta criteria classifies PFCs as acute or chronic, with chronic fluid collections subdivided into pseudocysts and walled-off pancreatic necrosis (WOPN). Establishing adequate nutritional support is an essential step in the management of PFCs. Early attempts at oral feeding can be trialed in patients with mild pancreatitis. Enteral feeding should be implemented in patients with moderate to severe pancreatitis. Jejunal feeding remains the preferred route of enteral nutrition. Symptomatic PFCs require drainage; options include surgical, percutaneous, or endoscopic approaches. With the advent of newer and more advanced endoscopic tools and expertise, and an associated reduction in health care costs, minimally invasive endoscopic drainage has become the preferable approach. An endoscopic ultrasonography-guided approach using a seldinger technique is the preferred endoscopic approach. Both plastic stents and metal stents are efficacious and safe; however, metal stents may offer an advantage, especially in infected pseudocysts and in WOPN. Direct endoscopic necrosectomy is often required in WOPN. Lumen apposing metal stents that allow for direct endoscopic necrosectomy and debridement through the stent lumen are preferred in these patients. Endoscopic retrograde cholangio pancreatography with pancreatic duct (PD) exploration should be performed concurrent to PFC drainage. PD disruption is associated with an increased severity of pancreatitis, an increased risk of recurrent attacks of pancreatitis and long-term complications, and a decreased rate of PFC resolution after drainage. Any pancreatic ductal disruption should be bridged with endoscopic stenting. PMID:26900288

  18. Evaluation of Quality of Life Following Placement of Self-Expanding Plastic Stents as a Bridge to Surgery in Patients Receiving Neoadjuvant Therapy for Esophageal Cancer

    PubMed Central

    Cannon, Robert M.; Brown, Russell E.; Ellis, Susan F.; Williams, Sharon; Scoggins, C.R.; Abbas, Abbas E.

    2014-01-01

    Purpose. To determine whether self-expanding plastic stent (SEPS) placement significantly improves quality of life and maintains optimal nutrition while allowing full-dose neoadjuvant therapy (NAT) in patients with esophageal cancer. Patients and Methods. A prospective, dual-institution, single-arm, phase II (http://ClinicalTrials.gov: NCT00727376) evaluation of esophageal cancer patients undergoing NAT prior to resection. All patients had a self-expanding polymer stent placed prior to NAT. The European Organisation for Research and Treatment of Cancer QLQ-C30 and QLQ-OG25, Functional Assessment of Cancer Therapy–Anorexia, and Functional Assessment of Cancer Therapy–General surveys were administered prior to stenting, within 1 week post-stent placement, and at the completion of neoadjuvant therapy. Results. Fifty-two patients were enrolled; 3 (5.8%) had stent migrations requiring replacement. There were no instances of esophageal erosion or perforation. All patients received some form of neoadjuvant therapy. Thirty-six (69%) received chemoradiation; 34 (93%) of these patients received the planned dose of chemotherapy, and 27 (75%) received the full planned dose of radiotherapy. There were 16 (31%) patients receiving chemotherapy alone; 12 (74%) of patients in the chemotherapy-alone group completed the planned dose of therapy. Conclusion. Placement of SEPS appears to provide significant improvement in quality of life related to dysphagia and eating restriction in patients with esophageal cancer undergoing neoadjuvant therapy. Consideration of SEPS instead of percutaneous feeding tube should be initiated as a first line in dysphagia palliation and NAT nutritional support. PMID:24567281

  19. The 10-year Trend of Periprocedural Complication Following Carotid Artery Stenting; Single Center Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Jeong-Ho; Kang, Jihoon; Yeo, Min-Ju

    PurposeCarotid endarterectomy and stenting are used to treat carotid stenosis, with the volume of carotid artery procedures increasing over the past decade. We investigated the 10-year trend of periprocedural complications with an increasing procedure volume of carotid stenting at a single tertiary hospital.MethodsWe collected 416 consecutive cases (384 patients) of carotid artery stenting performed for either symptomatic (231 cases, 55.5 %) or asymptomatic (185 cases, 44.5 %) internal carotid artery stenosis at a single center. Periprocedural complication was defined as any stroke, myocardial infarction, or death. Procedure-related outcome included any dissection, hemodynamic event, or periprocedural complication.ResultsThe mean age was 68.8 years (82.8 % males;more » range of 20–89 years); 23.9 % were older than 75 years. Before the procedure, 99.3 and 56.0 % of patients received antiplatelet and lipid-lowering medication, respectively. The overall periprocedural complication rate was 3.6 % (1.6 and 5.2 % in the asymptomatic and symptomatic group, respectively). The composite outcome of any stroke or death was 3.4 %. Periprocedural complication and procedure-related outcome showed a decremental trend with increasing procedure volume, and this trend remained after adjusting for confounders.ConclusionsOur study suggests that carotid stenting at an experienced center might reduce the periprocedural complications. Our periprocedural complication rate of carotid artery stenting may be comparable to, or somewhat lower than, that reported in other clinical trials.« less

  20. Endoscopic dacryocystorhinostomy with silicone, polypropylene, and T-tube stents; randomized controlled trial of efficacy and safety.

    PubMed

    Okuyucu, Semsettin; Gorur, Hatice; Oksuz, Huseyin; Akoglu, Ertap

    2015-01-01

    To compare the efficacy and safety of endoscopic dacryocystorhinostomy (En-DCR) with different stent materials for lacrimal sac intubation in primary nasolacrimal ductal obstructions. Randomized controlled study with three parallel groups. Level of evidence is 1b. A total of 91 patients (five bilateral) with primary nasolacrimal duct obstruction (NLDO) at a tertiary referral center scheduled for En-DCR were to allocated into three stent groups with a sealed envelope and were randomized into three treatments: silicone, Prolene (polypropylene), and otologic T-tube. Ophthalmology and otolaryngology clinics evaluated the patients preoperatively and postoperatively with endoscopes, lacrimal system syringing, and dacryocystography. The success of the stents was evaluated 12 months after surgery with symptom relief and ostial patency. Complications were also noted. The overall success rate of the En-DCR in the stent groups was 78.1% (75/96); specifically, 87.5% (28/32) with silicone, 84.4% (27/32) with Prolene, and 62.5% (20/32) with T-tube. The efficacy of the procedures with the T-tube was significantly lower than that of the Prolene and silicone (p = .031, χ(2) test). There were no significant differences between the silicone and Prolene (p = .718, χ(2) test). Prolene was found to be related with orbital complications. Spontaneous loss is a particular complication of otologic T-tube and highly portends to failure. The results of our study suggest that efficacy, defined as anatomic and functional success, is equally high for silicone and Prolene stents and lower for otologic T-tube in En-DCR.

  1. The citation of relevant systematic reviews and randomised trials in published reports of trial protocols.

    PubMed

    Pandis, Nikolaos; Fleming, Padhraig S; Koletsi, Despina; Hopewell, Sally

    2016-12-07

    It is important that planned randomised trials are justified and placed in the context of the available evidence. The SPIRIT guidelines for reporting clinical trial protocols recommend that a recent and relevant systematic review should be included. The aim of this study was to assess the use of the existing evidence in order to justify trial conduct. Protocols of randomised trials published over a 1-month period (December 2015) indexed in PubMed were obtained. Data on trial characteristics relating to location, design, funding, conflict of interest and type of evidence included for trial justification was extracted in duplicate and independently by two investigators. The frequency of citation of previous research including relevant systematic reviews and randomised trials was assessed. Overall, 101 protocols for RCTs were identified. Most proposed trials were parallel-group (n = 74; 73.3%). Reference to an earlier systematic review with additional randomised trials was found in 9.9% (n = 10) of protocols and without additional trials in 30.7% (n = 31), while reference was made to randomised trials in isolation in 21.8% (n = 22). Explicit justification for the proposed randomised trial on the basis of being the first to address the research question was made in 17.8% (n = 18) of protocols. A randomised controlled trial was not cited in 10.9% (95% CI: 5.6, 18.7) (n = 11), while in 8.9% (95% CI: 4.2, 16.2) (n = 9) of the protocols a systematic review was cited but did not inform trial design. A relatively high percentage of protocols of randomised trials involves prior citation of randomised trials, systematic reviews or both. However, improvements are required to ensure that it is explicit that clinical trials are justified and shaped by contemporary best evidence.

  2. Evidence-Based Carotid Interventions for Stroke Prevention: State-of-the-art Review

    PubMed Central

    Morris, Dylan R.; Ayabe, Kengo; Inoue, Takashi; Sakai, Nobuyuki; Bulbulia, Richard; Halliday, Alison

    2017-01-01

    Carotid artery stenosis is responsible for between 10–20% of all ischaemic strokes. Interventions, such as carotid end-arterectomy and carotid stenting, effectively reduce the risk of stroke in selected individuals. This review describes the history of carotid interventions, and summarises reliable evidence on the safety and efficacy of these interventions gained from large randomised clinical trials. Early trials comparing carotid endarterectomy to medical therapy alone in symptomatic patients, and asymptomatic patients, demonstrated that endarterectomy halved the risk of stroke and perioperative death in these two unique populations. The absolute risk reduction was smaller in the asymptomatic carotid trials, consistent with their lower absolute stroke risk. More recent trials in symptomatic patients, suggest that carotid stenting has similar long term durability to carotid endarterectomy, but possibly has higher procedural hazards dominated by non-disabling strokes. The Asymptomatic Carotid Surgery Trial-2, along with individual patient data meta-analysis of all asymptomatic trials, will provide reliable evidence for the choice of intervention in asymptomatic patients in whom a decision has been made for carotid revascularisation. Given improvements in effective cardiovascular medical therapy, in particular lipid-lowering medications, there is renewed uncertainty as to whether carotid interventions still provide meaningful net reductions in stroke risk in asymptomatic populations. Four large trials in Europe and the US are currently underway, and are expected to report longterm results in the next decade. It is essential that surgeons, interventionalists, and physicians continue to randomise large numbers of patients from around the world to clarify current uncertainty around the management of asymptomatic carotid stenosis. PMID:28260723

  3. Long-term forecasting and comparison of mortality in the Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial: prospective validation of the SYNTAX Score II.

    PubMed

    Campos, Carlos M; van Klaveren, David; Farooq, Vasim; Simonton, Charles A; Kappetein, Arie-Pieter; Sabik, Joseph F; Steyerberg, Ewout W; Stone, Gregg W; Serruys, Patrick W

    2015-05-21

    To prospectively validate the SYNTAX Score II and forecast the outcomes of the randomized Evaluation of the Xience Everolimus-Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) Trial. Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization is a prospective, randomized multicenter trial designed to establish the efficacy and safety of percutaneous coronary intervention (PCI) with the everolimus-eluting stent compared with coronary artery bypass graft (CABG) surgery in subjects with unprotected left-main coronary artery (ULMCA) disease and low-intermediate anatomical SYNTAX scores (<33). After completion of patient recruitment in EXCEL, the SYNTAX Score II was prospectively applied to predict 4-year mortality in the CABG and PCI arms. The 95% prediction intervals (PIs) for mortality were computed using simulation with bootstrap resampling (10 000 times). For the entire study cohort, the 4-year predicted mortalities were 8.5 and 10.5% in the PCI and CABG arms, respectively [odds ratios (OR) 0.79; 95% PI 0.43-1.50). In subjects with low (≤22) anatomical SYNTAX scores, the predicted OR was 0.69 (95% PI 0.34-1.45); in intermediate anatomical SYNTAX scores (23-32), the predicted OR was 0.93 (95% PI 0.53-1.62). Based on 4-year mortality predictions in EXCEL, clinical characteristics shifted long-term mortality predictions either in favour of PCI (older age, male gender and COPD) or CABG (younger age, lower creatinine clearance, female gender, reduced left ventricular ejection fraction). The SYNTAX Score II indicates at least an equipoise for long-term mortality between CABG and PCI in subjects with ULMCA disease up to an intermediate anatomical complexity. Both anatomical and clinical characteristics had a clear impact on long-term mortality predictions and decision making between CABG and PCI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Clinical results of carotid artery stenting versus carotid endarterectomy

    PubMed Central

    Akinci, Tuba; Derle, Eda; Kibaroğlu, Seda; Harman, Ali; Kural, Feride; Cınar, Pınar; Kilinc, Munire; Akay, Hakki T.; Can, Ufuk; Benli, Ulku S.

    2016-01-01

    Objective: To review our results of carotid artery stenting (CAS) and carotid endarterectomy (CEA). Methods: We evaluated the medical records of patients undergoing carotid artery revascularization procedure, between 2001 and 2013 in Baskent University Hospital, Ankara, Turkey. Carotid artery stenting or CEA procedures were performed in patients with asymptomatic carotid stenosis (≥70%) or symptomatic stenosis (≥50%). Demographic data, procedural details, and clinical outcomes were recorded. Primary outcome measures were in 30-day stroke/transient ischemic attacks (TIA)/amaurosis fugax or death. Secondary outcome measures were nerve injury, bleeding complications, length of stay in hospital, stroke, restenosis (ICA patency), and all-cause death during long-term follow-up. Results: One hundred ninety-four CEA and 115 CAS procedures were performed for symptomatic and/or asymptomatic carotid artery stenosis. There is no significant differences 30-day mortality and neurologic morbidity between CAS (13%) and CEA procedures (7.7%). Length of stay in hospital were significantly longer in CEA group (p=0.001). In the post-procedural follow up, only in symptomatic patients, restenosis rate was higher in the CEA group (p=.045). The other endpoints did not differ significantly. Conclusions: Endovascular stent treatment of carotid artery atherosclerotic disease is an alternative for vascular surgery, especially for patients that are high risk for standard CEA. The increasing experience, development of cerebral protection systems and new treatment protocols increases CAS feasibility. PMID:27744460

  5. Stenting for symptomatic intracranial vertebrobasilar artery stenosis: 30-day results in a high-volume stroke center.

    PubMed

    Liu, Lian; Zhao, Xiaojing; Mo, Dapeng; Ma, Ning; Gao, Feng; Miao, Zhongrong

    2016-04-01

    Symptomatic intracranial vertebrobasilar artery stenosis (IVBS) carries a high annual risk of recurrent stroke. Endovascular therapy was a promising technique but recent trials suggest it may carry a risk of periprocedual complications especially in inexperienced hands. This prospective study was to evaluate the safety of endovascular therapy for severe symptomatic IVBS in a high volume stroke centre. Patients with symptomatic IVBS caused by 70-99% stenosis despite medical treatment of at least one antiplatelet agent and statin were enrolled. The patients were treated either with balloon-mounted stent or balloon pre-dilation plus self-expanding stent as determined by the operators following a guideline. The primary outcome was 30-day stroke, transient ischemic attack (TIA) and death after stenting. The secondary outcome was successful stent deployment. The baseline characteristics and outcomes of patients with basilar artery (BA) lesions and patients with vertebral artery V4 segment lesions (BA group vs V4 group) were compared. And the outcome of different Mori type lesions was also compared. From September 2013 to September 2014, 105 patients with stroke or TIA due to intracranial IVBS were screened and 97 patients were treated by stenting, including 52 patients with BA stenosis and 45 patients with V4 stenosis. The rate of 30-day stroke, TIA and death was 7.1%. All the three strokes happened in the BA group and were perforator strokes. The successful stent deployment rate was 100%. General anesthesia was more preferred in the BA group than in the V4 groups (96.2% vs 75.6%, p=0.005). The Apollo stent was used more for Mori A lesions (30.5% vs 7.9%, p=0.011) and had lower degree of residual stenosis (8.6% vs 12.6%, p=0.014) than Wingspan stent. Mori C lesions were more likely to have higher degree of residual stenosis than Mori A lesion (15.3% vs 7.4%, p=0.005). The short-term safety of endovascular stenting for patients with severe symptomatic IVBS in a high volume stroke centre was acceptable. Mori A lesions may have lower residual stenosis rate than the Mori C type lesions. Copyright © 2016. Published by Elsevier B.V.

  6. Preoperative biliary drainage using a fully covered self-expandable metallic stent for pancreatic head cancer: A prospective feasibility study.

    PubMed

    Togawa, Osamu; Isayama, Hiroyuki; Kawakami, Hiroshi; Nakai, Yousuke; Mohri, Dai; Hamada, Tsuyoshi; Kogure, Hirofumi; Kawakubo, Kazumichi; Sakamoto, Naoya; Koike, Kazuhiko; Kita, Hiroto

    2018-01-01

    The role of endoscopic preoperative biliary drainage (PBD) for pancreatic head cancer is controversial because of the high incidence of stent occlusion before surgery. This study was performed to evaluate the feasibility and safety of PBD using a fully covered self-expandable metallic stent (FCSEMS). This multicenter prospective study involved 26 patients treated for pancreatic head cancer with distal bile duct obstruction from April 2011 to March 2013. An FCSEMS was endoscopically placed in 24 patients. Among these, 7 patients were diagnosed with unresectable cancer, and 17 underwent surgery at a median of 18 days after FCSEMS placement. The main outcome measure was preoperative and postoperative adverse events. Two adverse events (cholecystitis and insufficient resolution of jaundice) occurred between FCSEMS placement and surgery (12%). Postoperative adverse events occurred in eight patients (47%). The cumulative incidence of stent-related adverse events 4 and 8 weeks after FCSEMS placement among the 24 patients who underwent this procedure were 19%. PBD using an FCSEMS is feasible in patients with resectable pancreatic head cancer. Placement of an FCSEMS can be an alternative PBD technique when surgery without delay is impossible. A larger randomized controlled trial is warranted.

  7. Effectiveness of Positioning Stents in Radiation-Induced Xerostomia in Patients with Tongue Carcinoma: A Randomized Controlled Trial.

    PubMed

    Mall, Priyanka; Chand, Pooran; Singh, Balendra Pratap; Rao, Jitendra; Siddarth, Ramashanker; Srivastava, Kirti

    2016-01-01

    The aim of this study was to perform an objective and subjective evaluation of the efficacy of positioning stents in radiation-induced xerostomia in patients with tongue carcinoma. A total of 30 patients with tongue carcinoma and undergoing conventional radiotherapy were randomly assigned to control (n = 15) and study (n = 15) groups, without and with a positioning stent, respectively. Assessment of salivary output reduction was done before and after radiotherapy, at 3- and 6-month intervals, by measurement of unstimulated and stimulated salivary flow rates (objective evaluation). Xerostomia (subjective evaluation) was noted using six items from the Quality of Life Head and Neck Module (QLQ-H&N35) as proposed by the European Organization for Research and Treatment of Cancer. The significance level was set at .05. Mean unstimulated and stimulated salivary flow rates at 3- and 6-month intervals revealed significantly (P < .05) higher scores for the study group as compared with the control group. The mean quality of life scores in the study group were significantly (P < .05) lower compared with the control group. The use of a positioning stent minimized radiation-induced xerostomia and its symptoms.

  8. Study design of the influence of SErotonin inhibition on patients with RENAl impairment or diabetes undergoing drug-eluting stent implantation (SERENADE) study: A multicenter, open-label, prospective, randomized study.

    PubMed

    Lee, Seung-Ah; Suh, Jung-Won; Park, Jin Joo; Yoon, Chang-Hwan; Cho, Young-Suk; Youn, Tae-Jin; Chae, In-Ho; Kim, Hyo-Soo; Kim, Sang-Hyun; Choi, Dong-Ju

    2015-07-01

    The rates of stent failure after percutaneous coronary intervention have decreased since the introduction of the drug-eluting stent (DES). However, chronic kidney disease (CKD) and diabetes mellitus (DM) remain strong clinical predictors of poor prognosis despite DES implantation. Sarpogrelate, a selective serotonin (5-hydroxytryptamine (HT)2a [5-HT2A]) receptor antagonist, has antiproliferative effects, reducing neointimal hyperplasia and smooth muscle cell proliferation, as well as potent antiplatelet action, inhibiting 5-HT-induced platelet aggregation. However, efficacy and safety data for sarpogrelate in patients with CKD or DM are limited. We aim to determine whether sarpogrelate has beneficial effects in patients with CDK or DM treated with DES implantation. The SERENADE trial is a multicenter, open-label, prospective, randomized study that will test the superiority of triple anti-platelet therapy (TAT; aspirin, clopidogrel, and sarpogrelate) to conventional dual antiplatelet therapy (DAT; aspirin and clopidogrel) in preventing late lumen loss 9 months after the index procedure in patients with CKD or DM. A total of 220 patients diagnosed with coronary artery disease with DM or CKD will be randomized to the TAT or DAT groups (1:1 ratio) after DES implantation. The primary endpoint is late lumen loss at 9 months assessed by quantitative coronary angiography. Secondary efficacy endpoints are composites of major adverse cardiovascular events including cardiac death, nonfatal myocardial infarction, and target lesion revascularization. Secondary safety endpoints are major bleeding events and hepatic or renal impairment. The SERENADE trial will provide insight on the efficacy of adjunctive therapy with sarpogrelate after DES implantation for patients with high-risk profiles such as CKD or DM. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov NCT02294643). Copyright © 2015. Published by Elsevier Inc.

  9. Clinical and angiographic risk factors for stroke and death within 30 days after carotid endarterectomy and stent-protected angioplasty: a subanalysis of the SPACE study.

    PubMed

    Stingele, Robert; Berger, Jürgen; Alfke, Karsten; Eckstein, Hans-Henning; Fraedrich, Gustav; Allenberg, Jens; Hartmann, Marius; Ringleb, Peter A; Fiehler, Jens; Bruckmann, H; Hennerici, M; Jansen, O; Klein, G; Kunze, A; Marx, P; Niederkorn, K; Schmiedt, W; Solymosi, L; Zeumer, H; Hacke, W

    2008-03-01

    Carotid endarterectomy (CEA) and carotid artery stenting (CAS) are used to prevent ischaemic stroke in patients with stenosis of the internal carotid artery. Better knowledge of risk factors could improve assignment of patients to these procedures and reduce overall risk. We aimed to assess the risk of stroke or death associated with CEA and CAS in patients with different risk factors. We analysed data from 1196 patients randomised to CAS or CEA in the Stent-Protected Angioplasty versus Carotid Endarterectomy in Symptomatic Patients (SPACE) trial. The primary outcome event was death or ipsilateral stroke (ischaemic or haemorrhagic) with symptoms that lasted more than 24 h between randomisation and 30 days after therapy. Six predefined variables were assessed as potential risk factors for this outcome: age, sex, type of qualifying event, side of intervention, degree of stenosis, and presence of high-grade contralateral stenosis or occlusion. The SPACE trial is registered at Current Controlled Trials, with the international standard randomised controlled trial number ISRCTN57874028. Risk of ipsilateral stroke or death increased significantly with age in the CAS group (p=0.001) but not in the CEA group (p=0.534). Classification and regression tree analysis showed that the age that gave the greatest separation between high-risk and low-risk populations who had CAS was 68 years: the rate of primary outcome events was 2.7% (8/293) in patients who were 68 years old or younger and 10.8% (34/314) in older patients. Other variables did not differ between the CEA and CAS groups. Of the predefined covariates, only age was significantly associated with the risk of stroke and death. The lower risk after CAS versus CEA in patients up to 68 years of age was not detectable in older patients. This finding should be interpreted with caution because of the drawbacks of post-hoc analyses.

  10. Prognostic value of "routine" cardiac stress imaging 5 years after percutaneous coronary intervention: the prospective long-term observational BASKET (Basel Stent Kosteneffektivitäts Trial) LATE IMAGING study.

    PubMed

    Zellweger, Michael J; Fahrni, Gregor; Ritter, Myriam; Jeger, Raban V; Wild, Damian; Buser, Peter; Kaiser, Christoph; Osswald, Stefan; Pfisterer, Matthias E

    2014-06-01

    This study sought to evaluate the prognostic value of routine stress myocardial perfusion scintigraphy (MPS) 5 years after percutaneous coronary intervention (PCI). Current appropriate use criteria define routine cardiac stress imaging <2 years after PCI as inappropriate and >2 years as uncertain in asymptomatic patients. All 339 of 683 BASKET (Basel Stent Kosteneffektivitäts Trial) 5-year survivors (55%) consenting to undergo protocol-mandated MPS and subsequent evaluation irrespective of symptoms were followed for major adverse cardiac events (MACE) (cardiac death, myocardial infarction [MI], or revascularization). For MPS, summed perfusion scores were calculated and perfusion defects were related to treated-vessel or remote myocardial areas. Patients were 72 ± 10 years of age, 18% were female, and 90% were free of angina. MPS findings were abnormal in 205 of 339 patients (60%) with complete follow-up. During 3.7 ± 0.3 years, there were 7 cardiac deaths, 18 MIs, and 47 revascularizations, resulting in a MACE rate of 4.4% and a cardiac mortality rate of 0.6% per year. Patients with abnormal MPS findings had higher hazard ratios (HR) for MACE (HR: 1.95; 95% confidence interval [CI]: 1.06 to 3.59; p = 0.032), and cardiac death/MI (HR: 2.50; 95% CI: 0.93 to 6.69; p = 0.066) than patients with normal MPS finding. MACE rates were similar in patients with symptomatic and silent ischemia (p = 0.61) but higher than in patients with normal MPS findings (p < 0.05 for both comparisons). MACE rates were independently predicted by remote ischemia but not by treated-vessel ischemia or scar. Abnormal MPS findings 5 years after PCI are frequent irrespective of symptoms. The predictive power of abnormal MPS lies more in the detection of persistent or progressing coronary artery disease in remote vessel areas than in the diagnosis of late intervention-related problems in treated vessels. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Superficial femoral artery TASC D Registry: twelve-month effectiveness analysis of the Pulsar-18 SE nitinol stent in patients with critical limb ischemia.

    PubMed

    Lichtenberg, M; Stahlhoff, W; Boese, D

    2013-08-01

    Single center observational study analyzing the primary patency rate and freedom from target lesions revascularization rate of the Pulsar-18 nitinol stent after recanalization of long superficial femoral artery (SFA) occlusions (TASC D) in 22 patients with critical limb ischemia (CLI). Between 1/2011 and 7/2011, 22 consecutive patients (9 male, 13 female) with chronic total occlusions (CTO) of the femoro-popliteal arteries presenting with CLI (17 patients with Rutherford 4 score, and 5 patients with Rutherford 5 score) were enrolled and successfully recanalized using the Pulsar-18 self-expanding (SE) nitinol stent (BIOTRONIK AG, Buelach, Switzerland). Primary patency at 12 months was defined as no binary restenosis (>50%) on Duplex ultrasound (PSVR<2.5) and respectively no target lesion revascularization performed within 12 months. The average lesion length of the treated femoro-popliteal segment was 315 mm. Performing spot stenting average stent length in all patients was 245 mm (minimal 215 mm, maximal 315 mm). Technical success, with establishing an antegrade straight line flow to the foot through a reopened SFA, was achieved in all 22 patients. Subintimal and intraluminal recanalization techniques were used. Two patients with Rutherford 5 score had a minor amputation shortly after the recanalization procedure. All other patients had a complete wound healing of their lesions during a 6 month follow-up. After 12 month follow-up the primary patency rate of the Pulsar-18 SE nitinol stent was 77% with a per protocol restenosis in 5 of 22 patients. Seventeen patients showed a walking capacity on treadmill test >300 meters (Rutherford II). Two patients with a documented restenosis were Rutherford, these patients were treated conservatively. Three patients with restenosis and a Rutherford III score were scheduled for an endovascular target lesion revascularization leading to a freedom from target lesion revascularization rate of 86%. Endovascular intervention of long SFA occlusions using subintimal or intraluminal recanalization technique with implantation of the Pulsar-18 SE nitinol stent in CLI patients is safe and clinically effective with a primary patency rate after 12 months of 77% and a freedom from target lesion revascularization rate of 86%.

  12. The Robinson Protocol: a treadmill anaerobic performance test.

    PubMed

    Robinson, Ellyn M; Graham, Louise B; Headley, Samuel A

    2004-08-01

    The current investigation was designed to further examine the reliability of the Robinson protocol, which is a run-to-exhaustion treadmill test. Robinson (10) originally examined this protocol with 5 subjects. The significance of the initial exploratory study was the impetus for expanding the study to examine the reliability of the protocol with a larger sample. Fifteen male subjects participated in 3 trial runs on the treadmill. The first trial was a modified McConnell (7) test to determine the aerobic capacity of each subject. The second and third trials were identical Robinson protocols (10). The first trial run mean, in seconds (262.04 +/- 74.50), was not significantly different from the second trial run mean (257.30 +/- 72.65), p = 0.526 (2 tailed). As expected, trial 1 and trial 2 were highly correlated (intraclass) (r = 0.927, p < 0.001). These results provide additional support for the hypothesis that the Robinson protocol with a greater subject pool is a reliable protocol that can be used in research studies interested in examining various physiological interventions or anaerobic training.

  13. Safety and Efficacy of Solitaire Stent Thrombectomy

    PubMed Central

    Campbell, Bruce C.V.; Hill, Michael D.; Rubiera, Marta; Menon, Bijoy K.; Demchuk, Andrew; Donnan, Geoffrey A.; Roy, Daniel; Thornton, John; Dorado, Laura; Bonafe, Alain; Levy, Elad I.; Diener, Hans-Christoph; Hernández-Pérez, María; Pereira, Vitor Mendes; Blasco, Jordi; Quesada, Helena; Rempel, Jeremy; Jahan, Reza; Davis, Stephen M.; Stouch, Bruce C.; Mitchell, Peter J.; Jovin, Tudor G.; Saver, Jeffrey L.

    2016-01-01

    Background and Purpose— Recent positive randomized trials of endovascular therapy for ischemic stroke used predominantly stent retrievers. We pooled data to investigate the efficacy and safety of stent thrombectomy using the Solitaire device in anterior circulation ischemic stroke. Methods— Patient-level data were pooled from trials in which the Solitaire was the only or the predominant device used in a prespecified meta-analysis (SEER Collaboration): Solitaire FR With the Intention for Thrombectomy as Primary Endovascular Treatment (SWIFT PRIME), Endovascular Treatment for Small Core and Anterior Circulation Proximal Occlusion With Emphasis on Minimizing CT to Recanalization Times (ESCAPE), Extending the Time for Thrombolysis in Emergency Neurological Deficits—Intra-Arterial (EXTEND-IA), and Randomized Trial of Revascularization With Solitaire FR Device Versus Best Medical Therapy in the Treatment of Acute Stroke Due to Anterior Circulation Large Vessel Occlusion Presenting Within Eight Hours of Symptom Onset (REVASCAT). The primary outcome was ordinal analysis of modified Rankin Score at 90 days. The primary analysis included all patients in the 4 trials with 2 sensitivity analyses: (1) excluding patients in whom Solitaire was not the first device used and (2) including the 3 Solitaire-only trials (excluding ESCAPE). Secondary outcomes included functional independence (modified Rankin Score 0–2), symptomatic intracerebral hemorrhage, and mortality. Results— The primary analysis included 787 patients: 401 randomized to endovascular thrombectomy and 386 to standard care, and 82.6% received intravenous thrombolysis. The common odds ratio for modified Rankin Score improvement was 2.7 (2.0–3.5) with no heterogeneity in effect by age, sex, baseline stroke severity, extent of computed tomography changes, site of occlusion, or pretreatment with alteplase. The number needed to treat to reduce disability was 2.5 and for an extra patient to achieve independent outcome was 4.25 (3.29–5.99). Successful revascularization occurred in 77% treated with Solitaire device. The rate of symptomatic intracerebral hemorrhage and overall mortality did not differ between treatment groups. Conclusions— Solitaire thrombectomy for large vessel ischemic stroke was safe and highly effective with substantially reduced disability. Benefits were consistent in all prespecified subgroups. PMID:26888532

  14. A New Fully Covered Self-Expandable Metal Stent for the Treatment of Postsurgical Benign Biliary Strictures.

    PubMed

    Wu, Jun; Zhou, Dong-Xun; Wang, Tian-Tian; Gao, Dao-Jian; Hu, Bing

    2017-09-01

    Endotherapy with plastic stent (PS) placement is the main modality for treating benign biliary strictures (BBSs). Fully covered self-expandable metal stents (FCSEMSs) are being increasingly used for BBS management, with high stricture resolution. However, traditional metal tents are associated with high migration, causing treatment failure. We investigated the efficacy and safety of a new FCSEMS for postsurgical BBS treatment and compared these parameters between the FCSEMS and PS treatment through retrospective analysis. The primary outcome measurements included stricture resolution, stricture recurrence, and complications. In total, 69 patients were included, of whom 32 underwent FCSEMS treatment and 37 underwent PS treatment. The technical success rate and the number of endoscopic retrograde cholangiopancreatography procedures were similar between the groups. The median stenting duration was 5.2 months (range 1.5-15.3) in the FCSEMS group and 10.7 months (range 2.5-22.6) in the PS group (P < 0.01). The stents removal rate was 96.9% in the FCSEMS group and 94.6% in the PS group. The stricture resolution rate based on intention-to-treat analysis was 83.8% in the PS group and 84.4% (27/32) in the FCSEMS group (P = 0.947), whereas the rates from per-protocol analysis were 88.6% (31/35) and 87.1% (27/31), respectively (P = 0.574). Early and late complications were similar between the groups. The median follow-up time was 43 months (range 13-71). The stricture recurrence rate was 11.1% (3/27) in the FCSEMS group and 16.1% (5/31) in the PS group (P = 0.435). The new FCSEMS and the PS approach showed similar efficacy and safety in postsurgical BBS treatment. However, the FCSEMS required fewer procedural steps and shorter stenting time, making it an effective alternative modality.

  15. Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section.

    PubMed

    Bulusu, Kartik V; Plesniak, Michael W

    2016-07-19

    The arterial network in the human vasculature comprises of ubiquitously present blood vessels with complex geometries (branches, curvatures and tortuosity). Secondary flow structures are vortical flow patterns that occur in curved arteries due to the combined action of centrifugal forces, adverse pressure gradients and inflow characteristics. Such flow morphologies are greatly affected by pulsatility and multiple harmonics of physiological inflow conditions and vary greatly in size-strength-shape characteristics compared to non-physiological (steady and oscillatory) flows (1 - 7). Secondary flow structures may ultimately influence the wall shear stress and exposure time of blood-borne particles toward progression of atherosclerosis, restenosis, sensitization of platelets and thrombosis (4 - 6, 8 - 13). Therefore, the ability to detect and characterize these structures under laboratory-controlled conditions is precursor to further clinical investigations. A common surgical treatment to atherosclerosis is stent implantation, to open up stenosed arteries for unobstructed blood flow. But the concomitant flow perturbations due to stent installations result in multi-scale secondary flow morphologies (4 - 6). Progressively higher order complexities such as asymmetry and loss in coherence can be induced by ensuing stent failures vis-à-vis those under unperturbed flows (5). These stent failures have been classified as "Types I-to-IV" based on failure considerations and clinical severity (14). This study presents a protocol for the experimental investigation of the complex secondary flow structures due to complete transverse stent fracture and linear displacement of fractured parts ("Type IV") in a curved artery model. The experimental method involves the implementation of particle image velocimetry (2C-2D PIV) techniques with an archetypal carotid artery inflow waveform, a refractive index matched blood-analog working fluid for phase-averaged measurements (15 - 18). Quantitative identification of secondary flow structures was achieved using concepts of flow physics, critical point theory and a novel wavelet transform algorithm applied to experimental PIV data (5, 6, 19 - 26).

  16. Protecting intellectual property associated with Canadian academic clinical trials - approaches and impact

    PubMed Central

    2012-01-01

    Intellectual property is associated with the creative work needed to design clinical trials. Two approaches have developed to protect the intellectual property associated with multicentre trial protocols prior to site initiation. The ‘open access’ approach involves publishing the protocol, permitting easy access to the complete protocol. The main advantages of the open access approach are that the protocol is freely available to all stakeholders, permitting them to discuss the protocol widely with colleagues, assess the quality and rigour of the protocol, determine the feasibility of conducting the trial at their centre, and after trial completion, to evaluate the reported findings based on a full understanding of the protocol. The main potential disadvantage of this approach is the potential for plagiarism; however if that occurred, it should be easy to identify because of the open access to the original trial protocol, as well as ensure that appropriate sanctions are used to deal with plagiarism. The ‘restricted access’ approach involves the use of non-disclosure agreements, legal documents that must be signed between the trial lead centre and collaborative sites. Potential sites must guarantee they will not disclose any details of the study before they are permitted to access the protocol. The main advantages of the restricted access approach are for the lead institution and nominated principal investigator, who protect their intellectual property associated with the trial. The main disadvantages are that ownership of the protocol and intellectual property is assigned to the lead institution; defining who ‘needs to know’ about the study protocol is difficult; and the use of non-disclosure agreements involves review by lawyers and institutional representatives at each site before access is permitted to the protocol, significantly delaying study implementation and adding substantial indirect costs to research institutes. This extra step may discourage sites from joining a trial. It is possible that the restricted access approach may contribute to the failure of well-designed trials without any significant benefit in protecting intellectual property. Funding agencies should formalize rules around open versus restricted access to the study protocol just as they have around open access to results. PMID:23270486

  17. Protecting intellectual property associated with Canadian academic clinical trials--approaches and impact.

    PubMed

    Ross, Sue; Magee, Laura; Walker, Mark; Wood, Stephen

    2012-12-27

    Intellectual property is associated with the creative work needed to design clinical trials. Two approaches have developed to protect the intellectual property associated with multicentre trial protocols prior to site initiation. The 'open access' approach involves publishing the protocol, permitting easy access to the complete protocol. The main advantages of the open access approach are that the protocol is freely available to all stakeholders, permitting them to discuss the protocol widely with colleagues, assess the quality and rigour of the protocol, determine the feasibility of conducting the trial at their centre, and after trial completion, to evaluate the reported findings based on a full understanding of the protocol. The main potential disadvantage of this approach is the potential for plagiarism; however if that occurred, it should be easy to identify because of the open access to the original trial protocol, as well as ensure that appropriate sanctions are used to deal with plagiarism. The 'restricted access' approach involves the use of non-disclosure agreements, legal documents that must be signed between the trial lead centre and collaborative sites. Potential sites must guarantee they will not disclose any details of the study before they are permitted to access the protocol. The main advantages of the restricted access approach are for the lead institution and nominated principal investigator, who protect their intellectual property associated with the trial. The main disadvantages are that ownership of the protocol and intellectual property is assigned to the lead institution; defining who 'needs to know' about the study protocol is difficult; and the use of non-disclosure agreements involves review by lawyers and institutional representatives at each site before access is permitted to the protocol, significantly delaying study implementation and adding substantial indirect costs to research institutes. This extra step may discourage sites from joining a trial. It is possible that the restricted access approach may contribute to the failure of well-designed trials without any significant benefit in protecting intellectual property. Funding agencies should formalize rules around open versus restricted access to the study protocol just as they have around open access to results.

  18. Meditations on secondary revascularisation in the aftermath of the SYNTAX trial.

    PubMed

    Garg, Scot; Serruys, Patrick W

    2009-05-01

    Many patients will experience a return of symptoms after their initial revascularisation procedure necessitating secondary revascularisation (SR). The options for this second procedure are inherently influenced by the primary method adopted for revascularisation. Patients with single vessel disease are most suited to percutaneous coronary intervention (PCI) for both primary and secondary revascularisation. The arrival of drug eluting stents, and evidence from trials of highly select populations has threatened the place of coronary artery bypass grafting (CABG) as the preferred method of revascularisation in those with multivessel disease. At present, and without robust evidence, PCI is increasingly being used to treat highly complex lesions, such that many question whether CABG is still has a role in primary revascularisation. The consequence for SR is that currently it is increasingly likely to be in response to in-stent restenosis, whereby previously it was performed in those with prior CABG. The recent SYNTAX trial has reaffirmed the position of CABG in the treatment of those with complex coronary disease. Consequently we believe that matters have turned a full circle, and expect that SR in the future is most likely to be in form of PCI on patients 8-15 years post primary CABG.

  19. Electronic Clinical Trial Protocol Distribution via the World-Wide Web

    PubMed Central

    Afrin, Lawrence B.; Kuppuswamy, Valarmathi; Slater, Barbara; Stuart, Robert K.

    1997-01-01

    Clinical trials today typically are inefficient, paper-based operations. Poor community physician awareness of available trials and difficult referral mechanisms also contribute to poor accrual. The Physicians Research Network (PRN) web was developed for more efficient trial protocol distribution and eligibility inquiries. The Medical University of South Carolina's Hollings Cancer Center trials program and two community oncology practices served as a testbed. In 581 man-hours over 18 months, 147 protocols were loaded into PRN. The trials program eliminated all protocol hardcopies except the masters, reduced photocopier use 59%, and saved 1.0 full-time equivalents (FTE), but 1.0 FTE was needed to manage PRN. There were no known security breaches, downtime, or content-related problems. Therefore, PRN is a paperless, user-preferred, reliable, secure method for distributing protocols and reducing distribution errors and delays because only a single copy of each protocol is maintained. Furthermore, PRN is being extended to serve other aspects of trial operations. PMID:8988471

  20. Complications at the Proximal Landing Zone of Endovascular Stent Grafts Deployed in Surgically Replaced Ascending Aorta.

    PubMed

    Kotha, Vamshi K; Herget, Eric J; Appoo, Jehangir J

    2016-11-01

    The ascending aorta, with its hostile angulations and forces, is the next frontier in the evolution of endovascular surgery. Type II hybrid arch repair, involving surgical replacement of the ascending aorta, arch debranching, and stent graft deployment in the ascending aortic graft, offers an opportunity to study the behavior of an endovascular prosthesis in the ascending aorta. We report complications seen at the proximal landing zone after type II hybrid arch repair. A dedicated imaging protocol was used to monitor 20 consecutive patients who underwent type II hybrid arch repair at a single center from June 2009 to July 2014. Mean age was 66 years (range, 47 to 82 years). Mean imaging follow-up was 34 months (range, 12 to 64 months). There was 1 operative death (5%). Bird beaking (>5 mm of nonapposition) of the stent graft at the proximal landing zone occurred in 12 patients, and >20 mm of bird beaking occurred in 7 patients. Proximal landing zone complications occurred in 4 patients (20%), comprising 2 type Ia endoleaks, 1 graft migration, and 1 graft infolding detected on postoperative days 4, 11, 5, and 755, respectively. Three patients underwent endovascular reintervention for proximal landing zone complications. There were no late deaths. Thoracic aortic stent grafts may be prone to proximal landing zone complications when deployed in the ascending aorta. Bird beaking is common when endografts are deployed in the Dacron (DuPont, Wilmington, DE) ascending aorta. Angulation issues will likely need to be overcome by stent graft refinement to enable future closed chest approaches to the ascending aorta. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. [External biliary fistulas selectively managed by endoscopic retrograde cholangiography with sphincterotomy and/or stent placement].

    PubMed

    Săftoiu, A; Gheonea, D I; Surlin, V; Ciurea, M E; Georgescu, A; Andrei, E; Blendea, A; Georgescu, C C; Georgescu, I; Ciurea, T

    2006-01-01

    External bile duct fistulas are inherent postoperative complications that usually appear after biliary tract surgery, traumatic bile duct injuries and liver surgery for hepatic hydatid disease or liver transplant. The management is highly individualized, while the success and long-term results of endoscopic and surgical techniques are conflicting. The study included 32 cases with external bile duct fistulas managed by endoscopic retrograde cholangiography (ERC) with sphincterotomy and/or stent placement, including "rendez-vous" procedures in 2 cases. The causes of the external fistula were represented by cholecystectomy with/without retained common bile duct stones or strictures (22 cases), cholecystectomy and drainage of a subphrenic abscess caused by severe acute pancreatitis (1 case) and surgical interventions for hepatic hydatid disease (9 cases). Due to the prospective protocol of the study we were able to apply an individualized endoscopic treatment: sphincterotomy with proper relief of the bile duct obstruction (stone extraction) or sphincterotomy with large-size (10 Fr) stent placement for large-sized bile duct defects. The results consisted in closure of the fistula in 3.5 +/- 1.7 days for the subgroup of patients with sphincterotomy alone. Among the patients with stent insertion, fistulas healed slower in 14 +/- 3.5 days. There were no complications after endoscopic treatment; however the stent could not be passed in one patient that required subsequent surgery. In conclusion, endoscopic intervention is the treatment of choice for small external biliary fistulas complicating biliary tract surgery or liver surgery for hepatic hydatid disease. When the fistula is large, the placement of a 10 Fr endoprosthesis becomes necessary, while failure of endoscopic treatment leads to surgery with hepatico-jejunal anastomosis.

  2. Improvements in Clinical Trials Information Will Improve the Reproductive Health and Fertility of Cancer Patients.

    PubMed

    Dauti, Angela; Gerstl, Brigitte; Chong, Serena; Chisholm, Orin; Anazodo, Antoinette

    2017-06-01

    There are a number of barriers that result in cancer patients not being referred for oncofertility care, which include knowledge about reproductive risks of antineoplastic agents. Without this information, clinicians do not always make recommendations for oncofertility care. The objective of this study was to describe the level of reproductive information and recommendations that clinicians have available in clinical trial protocols regarding oncofertility management and follow-up, and the information that patients may receive in clinical trials patient information sheets or consent forms. A literature review of the 71 antineoplastic drugs included in the 68 clinical trial protocols showed that 68% of the antineoplastic drugs had gonadotoxic animal data, 32% had gonadotoxic human data, 83% had teratogenic animal data, and 32% had teratogenic human data. When the clinical trial protocols were reviewed, only 22% of the protocols reported the teratogenic risks and 32% of the protocols reported the gonadotoxic risk. Only 56% of phase 3 protocols had gonadotoxic information and 13% of phase 3 protocols had teratogenic information. Nine percent of the protocols provided fertility preservation recommendations and 4% provided reproductive information in the follow-up and survivorship period. Twenty-six percent had a section in the clinical trials protocol, which identified oncofertility information easily. When gonadotoxic and teratogenic effects of treatment were known, they were not consistently included in the clinical trial protocols and the lack of data for new drugs was not reported. Very few protocols gave recommendations for oncofertility management and follow-up following the completion of cancer treatment. The research team proposes a number of recommendations that should be required for clinicians and pharmaceutical companies developing new trials.

  3. Percutaneous intraductal radiofrequency ablation in the management of unresectable Bismuth types III and IV hilar cholangiocarcinoma.

    PubMed

    Wang, Yu; Cui, Wei; Fan, Wenzhe; Zhang, Yingqiang; Yao, Wang; Huang, Kunbo; Li, Jiaping

    2016-08-16

    To assess the feasibility and safety of percutaneous intraductal radiofrequency ablation (RFA) for unresectable Bismuth types III and IV hilar cholangiocarcinoma. Percutaneous intraductal RFA combined with metal stent placement was successful in all patients without any technical problems; the technical success rate was 100%. Chemotherapy was administered to two patients. After treatment, serum direct bilirubin levels were notably decreased. Six patients died during the follow-up period. Median stent patency from the time of the first RFA and survival from the time of diagnosis were 100 days (95% confidence interval (CI), 85-115 days) and 5.3 months (95% CI, 2.5-8.1 months), respectively. No acute pancreatitis, bile duct bleeding and perforation, bile leakage, or other severe complications occurred. Four cases of procedure-related cholangitis, three cases of postoperative abdominal pain, and five cases of asymptomatic transient increase in serum amylase were observed. One patient who presented with stent blockage 252 days' post-procedure underwent repeat ablation. Between September 2013 and May 2015, nine patients with unresectable Bismuth types III and IV hilar cholangiocarcinoma who were treated with percutaneous intraductal RFA combined with metal stent placement after the percutaneous transhepatic cholangial drainage were included in the retrospective analysis. Procedure-related complications, stent patency, and survival after treatment were investigated. Percutaneous intraductal RFA combined with metal stent placement is a technically safe and feasible therapeutic option for the palliative treatment of unresectable Bismuth types III and IV hilar cholangiocarcinoma. Its long-term efficacy and safety is promising, but needs further study via randomized and prospective trials that include a greater number of patients.

  4. Comparison of cost-effectiveness of oral rapamycin plus bare-metal stents versus first generation of drug-eluting stents (from the Randomized Oral Rapamycin in Argentina [ORAR] 3 trial).

    PubMed

    Rodriguez, Alfredo E; Palacios, Igor; Rodriguez-Granillo, Alfredo M; Mieres, Juan R; Tarragona, Sonia; Fernandez-Pereira, Carlos; Solorzano, Leonardo; Pauletto, Ricardo; Serruys, Patrick W; Antoniucci, David

    2014-03-01

    The aim of this study was to compare 5-year cost-effectiveness and clinical outcomes of patients with oral rapamycin (OR) plus bare-metal stent versus the drug-eluting stent (DES) strategy. During 2006 to 2007, a total of 200 patients were randomized to OR (n = 100) and DES (n = 100). Primary end point was to compare costs of initial procedure and cost-effectiveness of both revascularization strategies. Safety was evaluated by the composite of death, myocardial infarction, and cerebrovascular accident. Efficacy was assessed by target vessel and target lesion revascularizations. The 2 groups had similar baseline demographic, clinical, and angiographic characteristics. In the DES group, paclitaxel-, zotarolimus-, and sirolimus-eluting stents were used. Five-year clinical follow-up was accomplished in 99% patients. The DES group had significantly higher procedural (p <0.001), discharge to first-year (p = 0.02), and 1- to 5-year costs (p <0.001) compared with the OR group. At 5 years, the composite end point of death, myocardial infarction, and cerebrovascular accident (12% in the OR group vs 25% in the DES group, p = 0.01) was significantly less in the OR group. Target vessel revascularization (14.5% in the OR group vs 21% in the DES group, p = 0.16) and target lesion revascularization (10% in the OR group vs 17.6% in the DES group, p = 0.05) were not significantly different. In conclusion, a strategy of OR plus bare-metal stent was cost saving than a first-generation DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Reduction of atherothrombotic burden before stent deployment in non-ST elevation acute coronary syndromes: Reduction of myocardial necrosis achieved with nose-dive manual thrombus aspiration (REMNANT) trial. A volumetric intravascular ultrasound study.

    PubMed

    Zimarino, Marco; Angeramo, Francesca; Prasad, Abhiram; Ruggieri, Benedetta; Malatesta, Sara; Prati, Francesco; Buttitta, Fiamma; De Caterina, Raffaele

    2016-11-01

    To test whether thrombus aspiration (TA) reduces the atherosclerotic burden in culprit lesions and "facilitate" percutaneous coronary intervention with stent (S-PCI) among patients with non-ST elevation acute coronary syndromes (NSTE-ACS). Evidence on the effects of TA adjunctive to S-PCI in NSTE-ACS is limited and controversial. TA was defined "aggressive" when using 7F devices or a catheter/artery ratio >0.6, "conservative" with 6F, and a catheter/artery ratio ≤0.6. Angiography and intravascular ultrasound (IVUS) were performed at baseline, after TA and after stent deployment. TA was accomplished in 61/76 patients (80%) with NSTE-ACS. The aspirated material was red thrombus in 23% and plaque fragments in 49% of cases. Compared with baseline, TA was associated with an 82% increase in minimal lumen diameter and a 15% reduction in diameter stenosis (P < 0.001 for both). After TA, IVUS documented a 24 and 16% increase in minimal lumen area and lumen volume, respectively (P < 0.001 for both), a 7% decrease in area stenosis through an 11% reduction of plaque + media volume (P < 0.001). When compared with "conservative", an "aggressive" TA was associated with a more pronounced reduction in percent area stenosis (P < 0.05) and an increase in percent stent expansion (P < 0.001). The plaque + media volume reduction after TA was correlated with stent expansion (r = 0.261, P = 0.046). Manual TA reduces atherothrombotic burden in culprit lesions of NSTE-ACS patients before S-PCI and, when deep plaque removal is obtained, TA optimizes subsequent stent expansion. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  6. Early outcomes with a single-sided access endovascular stent.

    PubMed

    Hofmann, Michael; Pecoraro, Felice; Planer, David; Pfammatter, Thomas; Puippe, Gilbert; Bettex, Dominique; Veith, Frank J; Lachat, Mario; Chaykovska, Lyubov

    2018-03-27

    The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events (MAEs) including all-cause mortality, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, bowel ischemia, and procedural blood loss ≥1000 mL. Performance end points included successful delivery and deployment of the device, freedom from aneurysm growth ≥5 mm, type I or type III endoleak, stent graft occlusion, conversion to open surgery, rupture, and stent graft migration. In the FIM study, one conversion to open surgery with >1000 mL of blood loss was registered perioperatively. In the pivotal study, no perioperative MAE was registered. Overall, at 1-year follow-up, two deaths and one aneurysm growth unrelated to endoleak were registered. The results of both the FIM and pivotal studies demonstrated that 39 of 40 procedures were successful for delivery and deployment of the Horizon stent graft. No MAE was registered during the follow-up. The primary safety and performance end points were met in both studies. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Stent thrombosis with bioabsorbable polymer drug-eluting stents: insights from the Food and Drug Administration database.

    PubMed

    Khan, Abdur R; Tripathi, Avnish; Farid, Talha A; Abaid, Bilal; Bhatt, Deepak L; Resar, Jon R; Flaherty, Michael P

    2017-11-01

    SYNERGY, a bioabsorbable polymer-based, everolimus-eluting stent (BP-DES), recently received regulatory approval in the USA for use in percutaneous coronary interventions. Yet, information on the safety of BP-DES in routine clinical practice is limited. Our aim was to compare the safety of the recently approved BP-DES with current durable polymer drug-eluting stents (DP-DES) by analyzing adverse events, namely, stent thrombosis (ST), reported to the Manufacturer and User Facility Device Experience (MAUDE) database. The MAUDE database requires nationwide mandatory notification for adverse events on devices approved for clinical use. This database was searched for adverse events reported between 1 October 2015 and 25 December 2016, encountered after the placement of either BP-DES or DP-DES. Only those adverse events were included where the exposure period to the stents was comparable after the index procedure. Of all the adverse events reported, the event of interest was ST. A total of 951 adverse events were reported. ST occurred in 48/951 of all events, 31/309 and 17/642 when BP-DES or DP-DES were used, respectively (P=0.00001). Of the 31 ST events with BP-DES, 68% (21/31) occurred within less than or equal to 24 h of the index procedure and 52% (16/31) occurred within less than or equal to 2 h. Our results raise the possibility of an increased risk of ST, particularly early ST (within 24 h), with the recently approved BP-DES. However, because of the inherent limitations of reporting within the MAUDE database, these data merely highlight a potential need for additional surveillance and randomized trials to assess further the safety of the bioabsorbable platform.

  8. Renal angioplasty and stenting: is it still indicated after ASTRAL and STAR studies?

    PubMed

    Henry, M; Benjelloun, A; Henry, I; Polydorou, A; Hugel, M

    2010-10-01

    A renal artery stenosis (RAS) is common among patients with atherosclerosis, up to a third of patients undergoing cardiac catheterization. Fibromuscular dysplasia is the next cause of RAS, commonly found in young women. Atherosclerosis RAS generally progresses overtime and is often associated with loss of renal mass and worsening renal function (RF). Percutaneous renal artery stent placement is the preferred method of revascularization for hemodynamically significant RAS according to ACC and AHA guidelines. Several randomized trials have shown the superiority of endovascular procedures to medical therapy alone. However, two studies ASTRAL and STAR studies were recently published and did not find any difference between renal stenting and medical therapy. But these studies have a lot of limitations and flaws as we will discuss (poor indications, poor results, numerous complications, failures, poor technique, inexperienced operators, ecc.). Despite these questionable studies, renal stenting keeps indications in patients with: uncontrolled hypertension; ischemic nephropathy; cardiac disturbance syndrome (e.g. "flash" pulmonary edema, uncontrolled heart failure or uncontrolled angina pectoris); solitary kidney. To improve the clinical response rates, a better selection of the patients and lesions is mandatory with: good non-invasive or invasive imaging; physiologic lesion assessment using transluminal pressure gradients; measurements of biomarkers (e.g., BNP); fractional flow reserve study. A problem remains after renal angioplasty stenting, the deterioration of the RF in 20-30% of the patients. Atheroembolism seems to play an important role and is probably the main cause of this R.F deterioration. The use of protection devices alone or in combination with IIb IIa inhibitors has been proposed and seems promising as shown in different recent reports. Renal angioplasty and stenting is still indicated but we need: a better patient and lesion selection; improvements in techniques and maybe the use of protection devices to reduce the risk of RF deterioration after renal stenting.

  9. Cost-effectiveness of percutaneous coronary intervention with cobalt-chromium everolimus eluting stents versus bare metal stents: Results from a patient level meta-analysis of randomized trials.

    PubMed

    Ferko, Nicole; Ferrante, Giuseppe; Hasegawa, James T; Schikorr, Tanya; Soleas, Ireena M; Hernandez, John B; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Valgimigli, Marco

    2017-05-01

    Second-generation drug eluting stents (DES) may reduce costs and improve clinical outcomes compared to first-generation DES with improved cost-effectiveness when compared to bare metal stents (BMS). We aimed to conduct an economic evaluation of a cobalt-chromium everolimus eluting stent (Co-Cr EES) compared with BMS in percutaneous coronary intervention (PCI). To conduct a cost-effectiveness analysis (CEA) of a cobalt-chromium everolimus eluting stent (Co-Cr EES) versus BMS in PCI. A Markov state transition model with a 2-year time horizon was applied from a US Medicare setting with patients undergoing PCI with Co-Cr EES or BMS. Baseline characteristics, treatment effects, and safety measures were taken from a patient level meta-analysis of 5 RCTs (n = 4,896). The base-case analysis evaluated stent-related outcomes; a secondary analysis considered the broader set of outcomes reported in the meta-analysis. The base-case and secondary analyses reported an additional 0.018 and 0.013 quality-adjusted life years (QALYs) and cost savings of $236 and $288, respectively with Co-Cr EES versus BMS. Results were robust to sensitivity analyses and were most sensitive to the price of clopidogrel. In the probabilistic sensitivity analysis, Co-Cr EES was associated with a greater than 99% chance of being cost saving or cost effective (at a cost per QALY threshold of $50,000) versus BMS. Using data from a recent patient level meta-analysis and contemporary cost data, this analysis found that PCI with Co-Cr EES is more effective and less costly than PCI with BMS. © 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc. © 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  10. A prospective multicenter study on self-expandable metallic stents as a bridge to surgery for malignant colorectal obstruction in Japan: efficacy and safety in 312 patients.

    PubMed

    Saito, Shuji; Yoshida, Shuntaro; Isayama, Hiroyuki; Matsuzawa, Takeaki; Kuwai, Toshio; Maetani, Iruru; Shimada, Mamoru; Yamada, Tomonori; Tomita, Masafumi; Koizumi, Koichi; Hirata, Nobuto; Kanazawa, Hideki; Enomoto, Toshiyuki; Sekido, Hitoshi; Saida, Yoshihisa

    2016-09-01

    Endoscopic stenting with a self-expandable metallic stent (SEMS) is a widely accepted procedure for malignant colonic obstruction. The Colonic Stent Safe Procedure Research Group conducted the present prospective feasibility study. Our objectives were to estimate the safety and feasibility of SEMS placement as a bridge to surgery (BTS) for malignant colorectal obstruction. We conducted a prospective, observational, single-arm, multicenter clinical trial from March 2012 to October 2013. Each patient was treated with an uncovered WallFlex enteral colonic stent. Patients were followed up until discharge after surgery. A total of 518 consecutive patients were enrolled in this study. The cohort intended for BTS consisted of 312 patients (61 %), and the stent could be released in 305 patients. Technical and clinical success rates were 98 and 92 %, respectively. Elective surgery was performed in 297 patients, and emergency surgery was performed in eight patients for the treatment of complications. The overall preoperative complication rate was 7.2 %. Major complications, including perforation, occurred in 1.6 %, persistent colonic obstruction occurred in 1.0 %, and stent migration occurred in 1.3 % patients. The median time from SEMS to surgery was 16 days. Silent perforations were observed in 1.3 %. Open and laparoscopic surgery was performed in 121 and 184 patients, respectively. The tumor could be resected in 297 patients. The primary anastomosis rate was 92 %. The rate of anastomotic leakage was 4 %, and the overall stoma creation rate was 10 %. The median duration of hospitalization following surgery was 12 days. Overall postoperative morbidity and mortality rates were 16 and 0.7 %, respectively. This largest, multicenter, prospective study demonstrates the feasibility of SEMS placement as a BTS for malignant colorectal obstruction. SEMS serves as a safe and effective BTS with acceptable stoma creation and complication rates in patients with acute malignant colonic obstruction.

  11. Onset and extent of platelet inhibition by clopidogrel loading in patients undergoing elective coronary stenting: the Plavix Reduction Of New Thrombus Occurrence (PRONTO) trial.

    PubMed

    Gurbel, Paul A; Cummings, Charles C; Bell, Christopher R; Alford, Amanda B; Meister, Andrew F; Serebruany, Victor L

    2003-02-01

    Despite the common practice of clopidogrel loading for coronary stenting, the time dependence and degree of platelet inhibition after this therapy are not well defined. We sought to establish an optimal clopidogrel dosing regimen for sustained platelet inhibition in stented patients. Platelets were assessed by conventional aggregation with 5 micromol/L adenosine diphosphate (ADP), 1 microg/mL collagen (COLL), and 750 micromol/L arachidonic acid; whole blood aggregation by 1 microg/mL collagen (WBA); shear-induced closure time (CT); contractile force (CF); and expression of 9 surface receptors by flow cytometry in 100 patients undergoing elective stent placement without glycoprotein (GP) IIb/IIIa receptor antagonists. Blood was obtained at baseline and serially over 5 days poststenting after different clopidogrel loading regimens: 300 mg 24 hours before (Group A), 12 hours before (Group B), 3 to 6 hours before (Group C), and 75 mg at the time of intervention (Group D). Before stenting, ADP, COLL, CT, and WBA were reduced by clopidogrel loading (P <.05). CF was not affected by clopidogrel. Before stenting, GP IIb/IIIa expression increased in groups A through C (P <.05), whereas PECAM-1 and CD107a were reduced (P <.05). At 2 hours and 2 days poststenting, platelets, in general, exhibited an increase in activity that was most inhibited by clopidogrel loading. Clopidogrel inhibited GP Ib, platelet/endothelial cell adhesion molecule-1, CD 107a, CD 151, and GP IIb/IIIa expression at day 5 poststenting. A 300 mg clopidogrel load given 3 to 24 hours before stenting inhibits platelets at the time of the procedure and reduces poststent activity more than a 75 mg dose given at the time of the procedure. The inhibition of adhesive molecule expression may also contribute an antithrombotic effect. Poststent activation of platelets may warrant higher periprocedural dosing.

  12. Results From the VISIBILITY Iliac Study: Primary and Cohort Outcomes at 9 Months.

    PubMed

    Rundback, John H; Peeters, Patrick; George, Jon C; Jaff, Michael R; Faries, Peter L

    2017-06-01

    To evaluate the safety and effectiveness of primary stenting of the common (CIA) or external iliac artery (EIA) using the Visi-Pro Balloon-Expandable Peripheral Stent System for treatment of stenotic, restenotic, or occluded lesions. Between 2011 and 2012, 75 patients (mean age 64.2±8.9 years; 46 men) with Rutherford category 2-4 ischemia and atherosclerotic lesions ≤10 cm in length underwent iliac artery stenting at 17 centers in the United States and Europe. The primary outcome of the study was the major adverse event (MAE) rate at 9 months postprocedure [composite of periprocedural death, in-hospital myocardial infarction, clinically driven target lesion revascularization (CD-TLR), and amputation of the treated limb]. Secondary outcomes included 30-day MAE rate, 9-month primary patency, changes in ankle-brachial index (ABI) and the Walking Impairment Questionnaire at 30 days and 9 months postprocedure, device success, and clinically driven target vessel revascularization (CD-TVR) at 30 days and 9 months. Outcomes in specific patient cohorts (ie, gender, stent location, calcification severity, and lesion grade) were analyzed. Eighty-one stents were implanted in 61 CIA and 15 EIA lesions (41 with moderate/severe calcification). The mean lesion treated length was 29.3±13.9 mm. All devices were successfully deployed. MAE occurred in 3 (4.0%) of 75 subjects at 9 months. Primary patency and freedom from CD-TVR at 9 months were both 95.8%. ABI improved from 0.67±0.14 at baseline to 0.94±0.14 and 0.96±0.16 at 30 days and 9-month follow-up, respectively (p<0.001 for both). There were no differences with respect to any of the analyzed patient characteristics, including gender. Nine-month results of the VISIBILITY Iliac stent study ( ClinicalTrials.gov identifier NCT01402700) demonstrated safety and effectiveness for the treatment of atherosclerotic CIA and EIA lesions with the Visi-Pro stent across all treated cohorts.

  13. Development of a manualized protocol of massage therapy for clinical trials in osteoarthritis.

    PubMed

    Ali, Ather; Kahn, Janet; Rosenberger, Lisa; Perlman, Adam I

    2012-10-04

    Clinical trial design of manual therapies may be especially challenging as techniques are often individualized and practitioner-dependent. This paper describes our methods in creating a standardized Swedish massage protocol tailored to subjects with osteoarthritis of the knee while respectful of the individualized nature of massage therapy, as well as implementation of this protocol in two randomized clinical trials. The manualization process involved a collaborative process between methodologic and clinical experts, with the explicit goals of creating a reproducible semi-structured protocol for massage therapy, while allowing some latitude for therapists' clinical judgment and maintaining consistency with a prior pilot study. The manualized protocol addressed identical specified body regions with distinct 30- and 60-min protocols, using standard Swedish strokes. Each protocol specifies the time allocated to each body region. The manualized 30- and 60-min protocols were implemented in a dual-site 24-week randomized dose-finding trial in patients with osteoarthritis of the knee, and is currently being implemented in a three-site 52-week efficacy trial of manualized Swedish massage therapy. In the dose-finding study, therapists adhered to the protocols and significant treatment effects were demonstrated. The massage protocol was manualized, using standard techniques, and made flexible for individual practitioner and subject needs. The protocol has been applied in two randomized clinical trials. This manualized Swedish massage protocol has real-world utility and can be readily utilized both in the research and clinical settings. Clinicaltrials.gov NCT00970008 (18 August 2009).

  14. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention.

    PubMed

    Baschet, Louise; Bourguignon, Sandrine; Marque, Sébastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117 762 patient-years with 76 randomised trials. The main effectiveness criterion was major cardiac event-free survival. Effectiveness and costs were modelled over a 5-year horizon using a three-state Markov model. Incremental cost-effectiveness ratios and a cost-effectiveness acceptability curve were calculated for a range of thresholds for willingness to pay per year without major cardiac event gain. Deterministic and probabilistic sensitivity analyses were performed. Base case results demonstrated that DES are dominant over BMS, with an increase in event-free survival and a cost-reduction of €184, primarily due to a diminution of second revascularisations, and an absence of myocardial infarction and stent thrombosis. These results are robust for uncertainty on one-way deterministic and probabilistic sensitivity analyses. Using a cost-effectiveness threshold of €7000 per major cardiac event-free year gained, DES has a >95% probability of being cost-effective versus BMS. Following DES price decrease, new-generation DES development and taking into account recent meta-analyses results, the DES can now be considered cost-effective regardless of selective indication in France, according to European recommendations.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Köklü, Erkan, E-mail: drerkankoklu@gmail.com; Arslan, Şakir; Yüksel, İsa Öner

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after themore » procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication.« less

  16. Comparison of inter-trial recovery times for the determination of critical power and W' in cycling.

    PubMed

    Karsten, Bettina; Hopker, James; Jobson, Simon A; Baker, Jonathan; Petrigna, Luca; Klose, Andreas; Beedie, Christopher

    2017-07-01

    Critical Power (CP) and W' are often determined using multi-day testing protocols. To investigate this cumbersome testing method, the purpose of this study was to compare the differences between the conventional use of a 24-h inter-trial recovery time with those of 3 h and 30 min for the determination of CP and W'. 9 moderately trained cyclists performed an incremental test to exhaustion to establish the power output associated with the maximum oxygen uptake (p[Formula: see text] max ), and 3 protocols requiring time-to-exhaustion trials at a constant work-rate performed at 80%, 100% and 105% of p[Formula: see text] max. Design: Protocol A utilised 24-h inter-trial recovery (CP 24 /W' 24 ), protocol B utilised 3-h inter-trial recovery (CP 3 /W' 3 ), and protocol C used 30-min inter-trial recovery period (CP 0.5 /W' 0.5 ). CP and W' were calculated using the inverse time (1/t) versus power (P) relation (P = W'(1/t) + CP). 95% Limits of Agreement between protocol A and B were -9 to 15 W; -7.4 to 7.8 kJ (CP/W') and between protocol A and protocol C they were -27 to 22 W; -7.2 to 15.1 kJ (CP/W'). Compared to criterion protocol A, the average prediction error of protocol B was 2.5% (CP) and 25.6% (W'), whilst for protocol C it was 3.7% (CP) and 32.9% (W'). 3-h and 30-min inter-trial recovery time protocols provide valid methods of determining CP but not W' in cycling.

  17. How to manage hypertension with atherosclerotic renal artery stenosis?

    PubMed

    Ricco, Jean-Baptiste; Belmonte, Romain; Illuminati, Guilio; Barral, Xavier; Schneider, Fabrice; Chavent, Bertrand

    2017-04-01

    The management of atherosclerotic renal artery stenosis (ARAS) in patients with hypertension has been the topic of great controversy. Major contemporary clinical trials such as the Cardiovascular Outcomes for Renal Artery lesions (CORAL) and Angioplasty and Stenting for Renal Atherosclerotic lesions (ASTRAL) have failed to show significant benefit of revascularization over medical management in controlling blood pressure and preserving renal function. We present here the implications and limitations of these trials and formulate recommendations for management of ARAS.

  18. Point of care platelet activity measurement in primary PCI [PINPOINT-PPCI]: a protocol paper.

    PubMed

    Johnson, Thomas W; Marsden, Debbie; Mumford, Andrew; Pike, Katie; Mundell, Stuart; Butler, Mark; Strange, Julian W; Bowles, Ruth; Rogers, Chris; Baumbach, Andreas; Reeves, Barnaby C

    2014-04-04

    Optimal treatment of acute ST-elevation myocardial infarction (STEMI) involves rapid diagnosis, and transfer to a cardiac centre capable of percutaneous coronary intervention (PCI) for immediate mechanical revascularisation. Successful treatment requires rapid return of perfusion to the myocardium achieved by thromboaspiration, passivation of the culprit lesion with stent scaffolding and systemic inhibition of thrombosis and platelet activation. A delicate balance exists between thrombosis and bleeding and consequently anti-thrombotic and antiplatelet treatment regimens continue to evolve. The desire to achieve reperfusion as soon as possible, in the setting of high platelet reactivity, requires potent and fast-acting anti-thrombotic/anti-platelet therapies. The associated bleeding risk may be minimised by use of short-acting anti-thrombotic intravenous agents. However, effective oral platelet inhibition is required to prevent recurrent thrombosis. The interaction between baseline platelet reactivity, timing of revascularisation and effective inhibition of thrombosis is yet to be formally investigated. We present a protocol for a prospective observational study in patients presenting with acute STEMI treated with primary PCI (PPCI) and receiving bolus/infusion bivalirudin and prasugrel therapy. The objective of this study is to describe variation in platelet reactivity, as measured by the multiplate platelet function analyser, at presentation, the end of the PPCI procedure and 1, 2, & 24 hours post-procedure. We intend to assess the prevalence of high residual platelet reactivity within 24 hours of PPCI in acute STEMI patients receiving prasugrel and bivalirudin. Additionally, we will investigate the association between high platelet reactivity before and after PPCI and the door-to-procedure completion time.This is a single centre study with a target sample size of 108 participants. The baseline platelet reactivity on presentation with a STEMI may impact on the effect of acute anti-thrombotic and anti-platelet therapy and expose patients to a heightened risk of bleeding or ongoing thrombosis. This study will define the baseline variation in platelet reactivity in a population of patients experiencing acute STEMI and assess the pharmacodynamic response to combined treatment with bivalirudin and prasugrel. The data obtained from this trial will be hypothesis generating for future trials testing alternative pharmacotherapies in the acute phase of treatment for STEMI. This study has approval from Wiltshire research ethics committee (10/H0106/87) and is registered with current controlled trials (http://www.controlled-trials.com/ISRCTN82257414).

  19. 2-Year Outcomes of High Bleeding Risk Patients After Polymer-Free Drug-Coated Stents.

    PubMed

    Garot, Philippe; Morice, Marie-Claude; Tresukosol, Damras; Pocock, Stuart J; Meredith, Ian T; Abizaid, Alexandre; Carrié, Didier; Naber, Christoph; Iñiguez, Andres; Talwar, Suneel; Menown, Ian B A; Christiansen, Evald H; Gregson, John; Copt, Samuel; Hovasse, Thomas; Lurz, Philipp; Maillard, Luc; Krackhardt, Florian; Ong, Paul; Byrne, Jonathan; Redwood, Simon; Windhövel, Ute; Greene, Samantha; Stoll, Hans-Peter; Urban, Philip

    2017-01-17

    A 1-year follow-up, polymer-free metallic stent coated with biolimus-A9 followed by 1-month dual antiplatelet therapy is safer and more effective than a bare-metal stent (BMS) for patients with high risk of bleeding. This study analyzed 2-year outcomes to determine whether these benefits are maintained. In a prospective, multicenter, double-blind trial, we randomized 2,466 high bleeding risk patients to receive a drug-coated stent (DCS) or a BMS followed by 1-month dual antiplatelet therapy. The primary safety endpoint was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy endpoint was clinically driven target lesion revascularization. At 2 years, the primary safety endpoint had occurred in 147 DCS and 180 BMS patients (15.3%) (hazard ratio: 0.80; 95% confidence interval: 0.64 to 0.99; p = 0.039). Clinically driven target lesion revascularization occurred for 77 DCS and 136 BMS patients (12.0%) (hazard ratio: 0.54; 95% confidence interval: 0.41 to 0.72; p < 0.0001). Major bleeding occurred in 8.9% of DCS and 9.2% of BMS patients (p = 0.95), and a coronary thrombotic event (myocardial infarction and/or stent thrombosis) occurred in 8.2% of DCS and 10.6% of BMS patients (p = 0.045). One-year mortality was 27.1% for a major bleed and 26.3% for a thrombotic event. At 2 years, multivariate correlates of major bleeding were age >75 years, anemia, raised plasma creatinine, and planned long-term anticoagulation. Correlates of the primary safety endpoint were age, anemia, congestive heart failure, multivessel disease, number of stents implanted, and use of a BMS rather than a DCS. Safety and efficacy benefits of DCS over BMS were maintained for 2 years in high bleeding risk patients. Rates of major bleeding and coronary thrombotic events were no different and were associated with a substantial and comparable mortality risk. (A Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug Coated Stent Versus the Gazelle Bare Metal Stent in Patients With High Risk of Bleeding [LEADERS FREE]; NCT01623180). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Treatment algorithms and protocolized care.

    PubMed

    Morris, Alan H

    2003-06-01

    Excess information in complex ICU environments exceeds human decision-making limits and likely contributes to unnecessary variation in clinical care, increasing the likelihood of clinical errors. I reviewed recent critical care clinical trials searching for information about the impact of protocol use on clinically pertinent outcomes. Several recently published clinical trials illustrate the importance of distinguishing efficacy and effectiveness trials. One of these trials illustrates the danger of conducting effectiveness trials before the efficacy of an intervention is established. The trials also illustrate the importance of distinguishing guidelines and inadequately explicit protocols from adequately explicit protocols. Only adequately explicit protocols contain enough detail to lead different clinicians to the same decision when faced with the same clinical scenario. Differences between guidelines and protocols are important. Guidelines lack detail and provide general guidance that requires clinicians to fill in many gaps. Computerized or paper-based protocols are detailed and, when used for complex clinical ICU problems, can generate patient-specific, evidence-based therapy instructions that can be carried out by different clinicians with almost no interclinician variability. Individualization of patient therapy can be preserved by these protocols when they are driven by individual patient data. Explicit decision-support tools (eg, guidelines and protocols) have favorable effects on clinician and patient outcomes and can reduce the variation in clinical practice. Guidelines and protocols that aid ICU decision makers should be more widely distributed.

Top