Sample records for stents interim analysis

  1. Antireflux Versus Conventional Plastic Stent in Malignant Biliary Obstruction: A Prospective Randomized Study.

    PubMed

    Vihervaara, Hanna; Grönroos, Juha M; Hurme, Saija; Gullichsen, Risto; Salminen, Paulina

    2017-01-01

    Endoscopic stents are used to relieve obstructive jaundice. The purpose of this prospective randomized study was to compare the patency of antireflux and conventional plastic biliary stent in relieving distal malignant biliary obstruction. All jaundiced patients admitted to hospital with suspected unresectable malignant distal biliary stricture between October 2009 and September 2010 were evaluated for the study. Eligible patients were randomized either to antireflux or conventional plastic stent arms. The primary endpoint was stent patency and the follow-up was continued either until the stent was occluded or until 6 months after the stent placement. At an interim analysis, antireflux stents (ARSs; n = 6) had a significantly shorter median patency of 34 (8-49) days compared with the conventional stent (n = 7) patency of 167 (38-214) days (P = .0003). Based on these results, the study was terminated due to ethical concerns. According to these results, the use of this ARS is not recommended.

  2. One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.

    PubMed

    Mehta, Ashwin B; Chandra, Praveen; Dalal, Jamshed; Shetty, Prabhakar; Desai, Devang; Chocklingam, K; Prajapati, Jayesh; Kumar, Pramod; Magarkar, Vilas; Vasawada, Apurva; Goyal, B K; Kumar, Viveka; Rao, V Suryaprakash; Babu, Ramesh; Parikh, Pritesh; Kaul, Upendra; Patil, Aruna; Mhetre, Tushar; Rangnekar, Hrishikesh

    2013-01-01

    The e-BioMatrix is a post marketing multicenter registry with an objective to evaluate the 2 year clinical safety and efficacy outcomes in patients treated with BioMatrix™ - Biolimus A9™ (BA9™) drug eluting stents (DES). Drug-eluting stents still have late-stage disadvantages that might be attributable to the permanent polymer. BioMatrix a new generation DES containing anti-proliferative drug Biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia. This interim analysis consists of a total of 1189 patients with 1418 lesions treated with BioMatrix stent who entered this multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, and 12 months with an extended follow-up of 2 years. Recommended antiplatelet regimen included clopidogrel and aspirin for 12 months. The mean age was 57.6 ± 10.9 years, 81.8% were males, comorbidity index was 1.20 ± 1.33, 68% presented with acute coronary syndrome, 49% had hypertension and 40.8% had diabetes mellitus. One-year clinical follow-up was completed in 987 patients at the time of interim analysis. The incidence of MACE is 0.45 for 1544 person-year follow-up. There were only 03 cases of ST (01 late ST) reported during this time. This registry demonstrates excellent one-year clinical safety and efficacy of BioMatrix stents. The 1-year result shows that BioMatrix stent may be a suitable alternative as compared to contemporary DESs which are currently available in the market for simple as well complex disease. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  3. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    PubMed

    Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L; Bonati, Leo H; van der Worp, H Bart; de Borst, Gert J; Lo, T Hauw; Gaines, Peter; Dorman, Paul J; Macdonald, Sumaira; Lyrer, Philippe A; Hendriks, Johanna M; McCollum, Charles; Nederkoorn, Paul J; Brown, Martin M

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4.0%) events of disabling stroke or death in the stenting group compared with 27 (3.2%) events in the endarterectomy group (hazard ratio [HR] 1.28, 95% CI 0.77-2.11). The incidence of stroke, death, or procedural myocardial infarction was 8.5% in the stenting group compared with 5.2% in the endarterectomy group (72 vs 44 events; HR 1.69, 1.16-2.45, p=0.006). Risks of any stroke (65 vs 35 events; HR 1.92, 1.27-2.89) and all-cause death (19 vs seven events; HR 2.76, 1.16-6.56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0.0197). Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery. Medical Research Council, the Stroke Association, Sanofi-Synthélabo, European Union. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. Early Removal of Double-J Stents Decreases Urinary Tract Infections in Living Donor Renal Transplantation: A Prospective, Randomized Clinical Trial.

    PubMed

    Liu, S; Luo, G; Sun, B; Lu, J; Zu, Q; Yang, S; Zhang, X; Dong, J

    2017-03-01

    The optimal timing for stent removal after renal transplantation remains controversial. This article describes an interim analysis of a randomized, prospective, double-blind trial aimed at detecting differences in urological complications between early ureteral stent removal at 1 week and routine ureteral stent removal at 4 weeks. Between October 2010 and March 2015, 103 patients who underwent living donor renal transplantation at a single center were pre-operatively randomly assigned to the early ureteral stent removal (at 1 week) group or the routine ureteral stent removal (at 4 weeks) group. Urinary symptoms, auxiliary examination results, and obstruction events were recorded during 3 months of follow-up. A cost analysis of both the hospitalization and postoperative periods was discussed. In total, 52 patients in the 1-week stent group and 51 patients in the 4-week stent group were analyzed. No serious adverse events were reported. Three episodes of urinary tract infections (UTIs) occurred in the 1-week stent group, and 18 such episodes were recorded in the 4-week stent group (5.8% vs 29.4%; P = .002). After adjusting for age, sex, ischemia time, renal artery number, body mass index, multiple arteries, and associated medical illness, regression analysis indicated that only stent duration was associated with UTI (OR, 8.791; 95% CI, 1.984-38.943; P = .004). The results of our study demonstrate that ureteral stent removal at 1 week reduces the risk of UTIs compared with routine removal at 4 weeks. Similar effects of ureteral stent removal on complication rates are observed for these two removal times. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    PubMed Central

    2010-01-01

    Summary Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. Findings The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4·0%) events of disabling stroke or death in the stenting group compared with 27 (3·2%) events in the endarterectomy group (hazard ratio [HR] 1·28, 95% CI 0·77–2·11). The incidence of stroke, death, or procedural myocardial infarction was 8·5% in the stenting group compared with 5·2% in the endarterectomy group (72 vs 44 events; HR 1·69, 1·16–2·45, p=0·006). Risks of any stroke (65 vs 35 events; HR 1·92, 1·27–2·89) and all-cause death (19 vs seven events; HR 2·76, 1·16–6·56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0·0197). Interpretation Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery. Funding Medical Research Council, the Stroke Association, Sanofi-Synthélabo, European Union. PMID:20189239

  6. Wing-shaped plastic stents vs. self-expandable metal stents for palliative drainage of malignant distal biliary obstruction: a randomized multicenter study.

    PubMed

    Schmidt, Arthur; Riecken, Bettina; Rische, Susanne; Klinger, Christoph; Jakobs, Ralf; Bechtler, Matthias; Kähler, Georg; Dormann, Arno; Caca, Karel

    2015-05-01

    Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS.  Stent failure occurred in 10/16 patients (62.5 %) in the winged-stent group vs. 4/18 patients (22.2 %) in the SEMS group (P = 0.034). The median time to stent failure was 51 days (range 2 - 92 days) for the winged stent and 80 days (range 28 - 266 days) for the SEMS (P = 0.002). Early stent failure (< 8 weeks after placement) occurred in 8 patients (50 %) vs. 2 patients (11.1 %), respectively (P = 0.022). After obtaining the results from this interim analysis, the study was discontinued because of safety concerns. The frequency of stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction. Study registration ClinicalTrials.gov (NCT01063634). © Georg Thieme Verlag KG Stuttgart · New York.

  7. A prospective, randomized study of the patency period of the plastic antireflux biliary stent: an interim analysis.

    PubMed

    Leong, Quan Wai; Shen, Mira L; Au, Kim W; Luo, Derek; Lau, James Y; Wu, Justin C; Chan, Francis K; Sung, Joseph J

    2016-02-01

    There is as yet no ideal design of a plastic biliary stent with the longest patency period. To study the safety and effective patency period of a new plastic antireflux biliary stent in the clinical setting. We conducted a prospective, randomized trial to compare the patency of 2 similar plastic biliary stents, one of which has an antiduodenobiliary reflux property. The study was conducted at 2 separate tertiary centers in 2 countries. Patients with inoperable distal malignant biliary obstruction were recruited. One of the 2 types of plastic stents under study was randomly chosen and inserted in the common bile duct of the study subjects. The subjects were followed until the end of study or occlusion occurrence. Our primary endpoint was the time to stent occlusion in days, with stent-related adverse events and all-cause mortality the secondary endpoints. A total of 16 subjects were recruited for the study; 7 were allocated to group A (ordinary Tannenbaum stent) and 9 to group B (antireflux biliary stent). Five of 7 subjects (71%) in group B had stent occlusion within 8 days, and the primary end point was reached in all 7 subjects within 30 days, whereas the primary endpoint was not reached within 30 days in any of the subjects in group A. Our data showed a significantly shorter stent patency period in group B compared with group A (P < .003). Small sample size. Routine use of antireflux plastic biliary stents in the palliative management of malignant biliary obstructions cannot be recommended at present. (Clinical trial registration number: NCT01142921.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  8. Effects of clopidogrel, prasugrel and ticagrelor on endothelial function, inflammatory and oxidative stress parameters and platelet function in patients undergoing coronary artery stenting for an acute coronary syndrome. A randomised, prospective, controlled study

    PubMed Central

    Schnorbus, Boris; Daiber, Andreas; Jurk, Kerstin; Warnke, Silke; König, Jochem; Krahn, Ulrike; Lackner, Karl; Munzel, Thomas; Gori, Tommaso

    2014-01-01

    Introduction Particularly in the setting of acute coronary syndromes, the interplay between vascular and platelet function has been postulated to have direct clinical implications. The present trial is designed to test the effect of clopidogrel, prasugrel and ticagrelor on multiple parameters of vascular function, platelet aggregation, oxidative and inflammatory stress before and up to 4 weeks after coronary artery stenting. Methods and analysis The study is designed as a three-arm, parallel design, randomised, investigator-blinded study. Patients with unstable angina or non-ST elevation myocardial infarction undergoing coronary intervention with a drug-eluting stent will be randomised to receive 600 mg clopidogrel, 60 mg prasugrel or 180 mg ticagrelor followed by oral therapy with the same drug. The primary endpoint of the trial is the impact of antiplatelet treatments on endothelial function as assessed by flow-mediated dilation at 1 day, 1 week and 1 month in patients who have undergone stenting. Secondary endpoints include the impact of study medications on parameters of macrovascular and microvascular function, platelet reactivity, oxidative and inflammatory stress. The study recruitment is currently ongoing and, after an interim analysis which was performed at 50% of the initially planned population, it is planned to continue until July 2015. Ethics and dissemination The protocol was approved by the local ethics committee. The trial will provide important pathophysiological insight on the relationship between platelet aggregation and endothelial function, two parameters that have been shown to influence patients’ prognosis. Trial registration number ClinicalTrials.gov Identifier: NCT01700322; EudraCT-Nr.: 2011-005305-73. Current V.1.3, from 24 February 2014. PMID:24801283

  9. Clinical outcomes with Biolimus (A9)™ eluting stent, 'BioMatrix' in diabetic patients--interim results from multicenter post market surveillance registry in India.

    PubMed

    Seth, Ashok; Hiremath, Shirish; Dani, Sameer; Kapoor, Sunil; Jain, R K; Abhaichand, Rajpal; Trivedi, Shailendra; Kaul, Upendra; Patil, Aruna; Khemnar, Bhushan; Rangnekar, Hrishikesh

    2013-01-01

    The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them. 334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months. The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients. In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  10. Clinical outcomes with Biolimus (A9)™ eluting stent, ‘BioMatrix’ in diabetic patients – interim results from multicenter post market surveillance registry in India

    PubMed Central

    Seth, Ashok; Hiremath, Shirish; Dani, Sameer; Kapoor, Sunil; Jain, R.K.; Abhaichand, Rajpal; Trivedi, Shailendra; Kaul, Upendra; Patil, Aruna; Khemnar, Bhushan; Rangnekar, Hrishikesh

    2013-01-01

    Objective The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. Background Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them. Methods 334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months. Results The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients. Conclusion In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients. PMID:24206882

  11. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    PubMed

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study to demonstrate superiority of ELA + PTA versus PTA alone for treating femoropopliteal ISR. (Randomized Study of Laser and Balloon Angioplasty Versus Balloon Angioplasty to Treat Peripheral In-stent Restenosis [EXCITE ISR]; NCT01330628). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    PubMed

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  13. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

    PubMed Central

    Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick

    2013-01-01

    Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased mortality compared with cobalt chromium everolimus eluting stents (1.52, 1.02 to 2.22). Overall, among all stent types, the newer generation durable polymer drug eluting stents (zotarolimus eluting stent-Resolute, cobalt chromium everolimus eluting stents, and platinum chromium everolimus eluting stents) were the most efficacious (lowest target vessel revascularization rate) stents, and cobalt chromium everolimus eluting stents were the safest with significant reductions in definite stent thrombosis (rate ratio 0.35, 0.21 to 0.53), myocardial infarction (0.65, 0.55 to 0.75), and death (0.72, 0.58 to 0.90) compared with bare metal stents. Conclusions Biodegradable polymer drug eluting stents are superior to first generation durable polymer drug eluting stents but not to newer generation durable polymer stents in reducing target vessel revascularization. Newer generation durable polymer stents, and especially cobalt chromium everolimus eluting stents, have the best combination of efficacy and safety. The utility of biodegradable polymer stents in the context of excellent clinical outcomes with newer generation durable polymer stents needs to be proven. PMID:24212107

  14. Automatic stent strut detection in intravascular OCT images using image processing and classification technique

    NASA Astrophysics Data System (ADS)

    Lu, Hong; Gargesha, Madhusudhana; Wang, Zhao; Chamie, Daniel; Attizani, Guilherme F.; Kanaya, Tomoaki; Ray, Soumya; Costa, Marco A.; Rollins, Andrew M.; Bezerra, Hiram G.; Wilson, David L.

    2013-02-01

    Intravascular OCT (iOCT) is an imaging modality with ideal resolution and contrast to provide accurate in vivo assessments of tissue healing following stent implantation. Our Cardiovascular Imaging Core Laboratory has served >20 international stent clinical trials with >2000 stents analyzed. Each stent requires 6-16hrs of manual analysis time and we are developing highly automated software to reduce this extreme effort. Using classification technique, physically meaningful image features, forward feature selection to limit overtraining, and leave-one-stent-out cross validation, we detected stent struts. To determine tissue coverage areas, we estimated stent "contours" by fitting detected struts and interpolation points from linearly interpolated tissue depths to a periodic cubic spline. Tissue coverage area was obtained by subtracting lumen area from the stent area. Detection was compared against manual analysis of 40 pullbacks. We obtained recall = 90+/-3% and precision = 89+/-6%. When taking struts deemed not bright enough for manual analysis into consideration, precision improved to 94+/-6%. This approached inter-observer variability (recall = 93%, precision = 96%). Differences in stent and tissue coverage areas are 0.12 +/- 0.41 mm2 and 0.09 +/- 0.42 mm2, respectively. We are developing software which will enable visualization, review, and editing of automated results, so as to provide a comprehensive stent analysis package. This should enable better and cheaper stent clinical trials, so that manufacturers can optimize the myriad of parameters (drug, coverage, bioresorbable versus metal, etc.) for stent design.

  15. An ovine in vivo framework for tracheobronchial stent analysis.

    PubMed

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Shea, Mary B; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2017-10-01

    Tracheobronchial stents are most commonly used to restore patency to airways stenosed by tumour growth. Currently all tracheobronchial stents are associated with complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. The present work develops a computational framework to evaluate tracheobronchial stent designs in vivo. Pressurised computed tomography is used to create a biomechanical lung model which takes into account the in vivo stress state, global lung deformation and local loading from pressure variation. Stent interaction with the airway is then evaluated for a number of loading conditions including normal breathing, coughing and ventilation. Results of the analysis indicate that three of the major complications associated with tracheobronchial stents can potentially be analysed with this framework, which can be readily applied to the human case. Airway deformation caused by lung motion is shown to have a significant effect on stent mechanical performance, including implications for stent migration, granulation formation and stent fracture.

  16. Finite Element Analysis of the Implantation Process of Overlapping Stents

    PubMed Central

    Xu, Jiang; Yang, Jie; Sohrabi, Salman; Zhou, Yihua; Liu, Yaling

    2017-01-01

    Overlapping stents are widely used in vascular stent surgeries. However, the rate of stent fractures (SF) and in-stent restenosis (ISR) after using overlapping stents is higher than that of single stent implantations. Published studies investigating the nature of overlapping stents rely primarily on medical images, which can only reveal the effect of the surgery without providing insights into how stent overlap influences the implantation process. In this paper, a finite element analysis of the overlapping stent implantation process was performed to study the interaction between overlapping stents. Four different cases, based on three typical stent overlap modes and two classical balloons, were investigated. The results showed that overlapping contact patterns among struts were edge-to-edge, edge-to-surface, and noncontact. These were mainly induced by the nonuniform deformation of the stent in the radial direction and stent tubular structures. Meanwhile, the results also revealed that the contact pressure was concentrated in the edge of overlapping struts. During the stent overlap process, the contact pattern was primarily edge-to-edge contact at the beginning and edge-to-surface contact as the contact pressure increased. The interactions between overlapping stents suggest that the failure of overlapping stents frequently occurs along stent edges, which agrees with the previous experimental research regarding the safety of overlapping stents. This paper also provides a fundamental understanding of the mechanical properties of overlapping stents. PMID:28690712

  17. Double versus single stenting for coronary bifurcation lesions: a meta-analysis.

    PubMed

    Katritsis, Demosthenes G; Siontis, George C M; Ioannidis, John P A

    2009-10-01

    Several trials have addressed whether bifurcation lesions require stenting of both the main vessel and side branch, but uncertainty remains on the benefits of such double versus single stenting of the main vessel only. We have conducted a meta-analysis of randomized trials including patients with coronary bifurcation lesions who were randomly selected to undergo percutaneous coronary intervention by either double or single stenting. Six studies (n=1642 patients) were eligible. There was increased risk of myocardial infarction with double stenting (risk ratio, 1.78; P=0.001 by fixed effects; risk ratio, 1.49 with Bayesian meta-analysis). The summary point estimate suggested also an increased risk of stent thrombosis with double stenting, but the difference was not nominally significant given the sparse data (risk ratio, 1.85; P=0.19). No obvious difference was seen for death (risk ratio, 0.81; P=0.66) and target lesion revascularization (risk ratio, 1.09; P=0.67). Stenting of both the main vessel and side branch in bifurcation lesions may increase myocardial infarction and stent thrombosis risk compared with stenting of the main vessel only.

  18. Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

    PubMed Central

    Kumar, Sunil; Fusaro, Mario; Amoroso, Nicholas; Kirtane, Ajay J; Byrne, Robert A; Williams, David O; Slater, James; Cutlip, Donald E; Feit, Frederick

    2012-01-01

    Objectives To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. Design Mixed treatment comparison meta-analysis. Data sources and study selection PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. Primary outcomes Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). Results From 42 trials with 22 844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents∼sirolimus eluting stents>paclitaxel eluting stents∼zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of “any” stent thrombosis. Conclusions Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such that the everolimus eluting stent was the most efficacious and safe. PMID:22885395

  19. Computational design analysis for deployment of cardiovascular stents

    NASA Astrophysics Data System (ADS)

    Tammareddi, Sriram; Sun, Guangyong; Li, Qing

    2010-06-01

    Cardiovascular disease has become a major global healthcare problem. As one of the relatively new medical devices, stents offer a minimally-invasive surgical strategy to improve the quality of life for numerous cardiovascular disease patients. One of the key associative issues has been to understand the effect of stent structures on its deployment behaviour. This paper aims to develop a computational model for exploring the biomechanical responses to the change in stent geometrical parameters, namely the strut thickness and cross-link width of the Palmaz-Schatz stent. Explicit 3D dynamic finite element analysis was carried out to explore the sensitivity of these geometrical parameters on deployment performance, such as dog-boning, fore-shortening, and stent deformation over the load cycle. It has been found that an increase in stent thickness causes a sizeable rise in the load required to deform the stent to its target diameter, whilst reducing maximum dog-boning in the stent. An increase in the cross-link width showed that no change in the load is required to deform the stent to its target diameter, and there is no apparent correlation with dog-boning but an increased fore-shortening with increasing cross-link width. The computational modelling and analysis presented herein proves an effective way to refine or optimise the design of stent structures.

  20. Treatment of central venous in-stent restenosis with repeat stent deployment in hemodialysis patients.

    PubMed

    Ronald, James; Davis, Bradley; Guevara, Carlos J; Pabon-Ramos, Waleska M; Smith, Tony P; Kim, Charles Y

    2017-05-15

    To report patency rates for stent deployment for treatment of in-stent stenosis of the central veins of the chest in hemodialysis patients. A retrospective analysis was performed on 29 patients who underwent 35 secondary percutaneous transluminal stent (PTS) deployments for in-stent stenosis within the central veins that were refractory to angioplasty and ipsilateral to a functioning hemodialysis access (in-stent PTS group). For comparison, patency data were acquired for 47 patients who underwent 78 successful percutaneous transluminal angioplasty (PTA) procedures for in-stent stenosis (in-stent PTA group) and 55 patients who underwent 55 stent deployments within native central vein stenosis refractory to angioplasty (native vein PTS group). The 3-, 6-, and 12-month primary lesion patency for the in-stent PTS group was 73%, 57%, and 32%, respectively. The 3-, 6-, and 12-month primary patency for the in-stent PTA group was 70%, 38%, and 17% and for the native vein PTS group was 78%, 57%, and 26%, which were similar to the in-stent PTS group (p = 0.20 and 0.41, respectively). The 3-, 6-, and 12-month secondary access patency was 91%, 73%, and 65% for the in-stent PTS group. Sub-analysis of the in-stent PTS group revealed no difference in primary (p = 0.93) or secondary patency rates (p = 0.27) of bare metal stents (n = 23) compared with stent grafts (n = 12). Stent deployment for central vein in-stent stenosis refractory to angioplasty was associated with reasonable patency rates, which were similar to in-stent PTA and native vein PTS.

  1. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    PubMed

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P < .001) was a risk factor for adverse events during stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. Surveillance and medical therapy following endovascular treatment of chronic cerebrospinal venous insufficiency.

    PubMed

    Forbes, Thomas L; Harris, Jeremy R; Kribs, Stewart W

    2012-06-01

    The debate regarding the possible link between chronic cerebrospinal venous insufficiency and multiple sclerosis (MS) is continuously becoming more and more contentious due to the current lack of level 1 evidence from randomized trials. Regardless of this continued uncertainty surrounding the safety and efficacy of this therapy, MS patients from Canada, and other jurisdictions, are traveling abroad to receive central venous angioplasty and, unfortunately, some also receive venous stents. They often return home with few instructions regarding follow-up or medical therapy. In response we propose some interim, practical recommendations for post-procedural surveillance and medical therapy, until further information is available.

  3. Repeated unit cell (RUC) approach for pure bending analysis of coronary stents.

    PubMed

    Ju, Feng; Xia, Zihui; Zhou, Chuwei

    2008-08-01

    Flexibility is one of the key properties of coronary stents. The objective of this paper is to characterize the bending behaviour of stents through finite element analysis with repeated unit cell (RUC) models. General periodic boundary conditions for the RUC under the pure bending condition are formulated. It is found that the proposed RUC approach can provide accurate numerical results of bending behaviour of stents with much less computational costs. Bending stiffness, post-yield bending behaviour and the relationship between moment and bending curvature are investigated for Palmaz-Schatz stents and stents with the V- and S-shaped links. It is found that the effect of link geometry on the bending behaviour of stent is significant. The behaviour of stents subjected to cyclic bending is also investigated.

  4. Meta-Analysis of Stenting versus Non-Stenting for the Treatment of Ureteral Stones

    PubMed Central

    Wang, Hai; Man, Libo; Li, Guizhong; Huang, Guanglin; Liu, Ning; Wang, Jianwei

    2017-01-01

    Background and aim Ureteroscopic lithotripsy (URL) and extracorporeal shock wave lithotripsy (ESWL) are two widely used methods for the treatment of ureteral stones. The need for ureteral stenting during these procedures is controversial. In this meta-analysis, we evaluated the benefits and disadvantages of ureteral stents for the treatment of ureteral stones. Methods Databases including PubMed, Embase and Cochrane library were selected for systematic review of randomized controlled trials (RCTs) comparing outcomes with or without stenting during URL and ESWL. Meta-analysis was performed using RevMan 5.3 and STATA 13.0 software. Results We identified 22 RCTs comparing stenting and non-stenting. The stented group was associated with longer operation time (WMD: 4.93; 95% CI: 2.07 to 7.84; p < 0.001), lower stone-free rate (OR: 0.55; 95% CI: 0.34 to 0.89; p = 0.01). In terms of complications, the incidence of hematuria (OR: 3.68; 95% CI: 1.86 to 7.29; p < 0.001), irritative urinary symptoms (OR: 4.40; 95% CI: 2.19 to 9.10; p < 0.001), urinary infection (OR: 2.23; 95% CI: 1.57 to 3.19; p < 0.001), and dysuria (OR: 3.90; 95% CI: 2.51 to 6.07; p < 0.001) were significantly higher in the stented group. No significant differences in visual analogue score (VAS), stricture formation, fever, or hospital stay were found between stenting and non-stenting groups. The risk of unplanned readmissions (OR: 0.63; 95% CI: 0.41 to 0.97; p = 0.04) was higher in the non-stented group. Conclusions Our analysis showed that stenting failed to improve the stone-free rate, and instead, it resulted in additional complications. However, ureteral stents are valuable in preventing unplanned re-hospitalization. Additional randomized controlled trials are still required to corroborate our findings. PMID:28068364

  5. A novel sax-stent method in treatment of ascending aorta and aortic arch aneurysms evaluated by finite element simulations.

    PubMed

    Arokiaraj, M C; De Beule, M; De Santis, G

    2017-02-01

    A novel stent method to simplify treatment of proximal ascending aorta and aortic arch aneurysms was developed and investigated by finite element analysis. Therapy of ascending aortic and aortic arch aneurysms is difficult and challenging and is associated with various complications. A 55mm wide×120mm long stent was designed without the stent graft and the stent was deployed by an endovascular method in a virtual patient-specific aneurysm model. The stress-strain analysis and deployment characteristics were performed in a finite element analysis using the Abaqus software. The stent, when embedded in the aortic wall, significantly reduced aortic wall stresses, while preserving the side coronary ostia and side branches in the aortic arch. When tissue growth was modeled computationally over the stent struts the wall stresses in aorta was reduced. This effect became more pronounced when increasing the thickness of the tissue growth. There were no abnormal stresses in the aorta, coronary ostium and at the origin of aortic branches. The stent reduced aneurysm expansion cause by hypertensive condition from 2mm without stenting to 1.3mm after stenting and embedding. In summary, we uncovered a simple treatment method using a bare nitinol stent without stent graft in the treatment of the proximal aorta and aortic arch aneurysms, which could eventually replace the complex treatment methods for this disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Quantitative optical coherence tomography analysis for late in-stent restenotic lesions.

    PubMed

    Fu, Qiang; Suzuki, Nobuaki; Kozuma, Ken; Miyagawa, Mutsuki; Nomura, Takahiro; Kawashima, Hideyuki; Shiratori, Yoshitaka; Ishikawa, Shuichi; Kyono, Hiroyuki; Isshiki, Takaaki

    2015-01-01

    Coronary optical coherence tomography (OCT) has the potential to identify in-stent neoatherosclerosis, which is a possible risk factor for late acute coronary events after drug-eluting stent implantation. The purpose of this study was to investigate differences between mid-term and late in-stent restenosis after stent implantation by quantitative and semiautomated tissue property analysis using OCT. In total, 1063 OCT image frames of 16 lesions in 15 patients were analyzed. This included 346 frames of 6 lesions in late in-stent restenosis, which was defined as restenosis that was not detected at 6 to 12 months but ≥ 12 months after follow-up coronary angiography. Signal attenuation was circumferentially analyzed using a dedicated semiautomated software. Attenuation was assessed along 200 lines delineated radially for analysis of the in-stent restenotic lesions (between the lumen and stent contours). All lines were anchored by the image wire to avoid artifacts resulting from wire location. Stronger signal attenuation at the frame level (2.46 ± 0.78 versus 1.47 ± 0.32, P < 0.001) and higher maximum signal intensity at the lesion level (9.19 ± 0.19 versus 8.84 ± 0.32, P = 0.018) were observed in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions. OCT demonstrated stronger signal attenuation and higher maximum signal intensity in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions, indicating the possibility of neoatherosclerosis.

  7. Auxetic coronary stent endoprosthesis: fabrication and structural analysis.

    PubMed

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar; Mir, Mariam; Minhas, Muhammad Asim; Shahid, Wakeel

    2015-07-04

    Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. The auxetic design was obtained via laser cutting, and surface treatment was performed with acid pickling and electropolishing, followed by an annealing process. In vitro mechanical analysis was performed to analyze the mechanical performance of the auxetic coronary stent. Scanning electronic microscopy (SEM) was used to determine the effects of fabrication processes on the topography of the auxetic stent. The elastic recoil (3.3%) of the in vitro mechanical analysis showed that the auxetic stent design effectively maintained the luminal patency of the coronary artery. Also, the auxetic coronary stent showed no foreshortening, therefore it avoids the problem of stent migration, by expanding in both the radial and longitudinal directions. By virtue of its synclastic behavior, the auxetic stent bulges outward when it is radially expanded through an inflated balloon.

  8. Impact of carotid stent cell design on vessel scaffolding: a case study comparing experimental investigation and numerical simulations.

    PubMed

    Conti, Michele; Van Loo, Denis; Auricchio, Ferdinando; De Beule, Matthieu; De Santis, Gianluca; Verhegghe, Benedict; Pirrelli, Stefano; Odero, Attilio

    2011-06-01

    To quantitatively evaluate the impact of carotid stent cell design on vessel scaffolding by using patient-specific finite element analysis of carotid artery stenting (CAS). The study was organized in 2 parts: (1) validation of a patient-specific finite element analysis of CAS and (2) evaluation of vessel scaffolding. Micro-computed tomography (CT) images of an open-cell stent deployed in a patient-specific silicone mock artery were compared with the corresponding finite element analysis results. This simulation was repeated for the closed-cell counterpart. In the second part, the stent strut distribution, as reflected by the inter-strut angles, was evaluated for both cell types in different vessel cross sections as a measure of scaffolding. The results of the patient-specific finite element analysis of CAS matched well with experimental stent deployment both qualitatively and quantitatively, demonstrating the reliability of the numerical approach. The measured inter-strut angles suggested that the closed-cell design provided superior vessel scaffolding compared to the open-cell counterpart. However, the full strut interconnection of the closed-cell design reduced the stent's ability to accommodate to the irregular eccentric profile of the vessel cross section, leading to a gap between the stent surface and the vessel wall. Even though this study was limited to a single stent design and one vascular anatomy, the study confirmed the capability of dedicated computer simulations to predict differences in scaffolding by open- and closed-cell carotid artery stents. These simulations have the potential to be used in the design of novel carotid stents or for procedure planning.

  9. Numerical investigations of the mechanical properties of braided vascular stents.

    PubMed

    Fu, Wenyu; Xia, Qixiao; Yan, Ruobing; Qiao, Aike

    2018-01-01

    Braided stents, such as Pipeline Embolization Device (PED; ev3 Neurovascular, Irvine, CA, USA), are commonly used to treat cerebral aneurysms. However, little information is available on the compression and bending characteristics of such stents. This paper investigates how geometrical parameters of braided stents influence their radial compression and bending characteristics. Six groups of braided stent models with different braiding angles, numbers of wires and wire diameters are constructed. Parametric analyses of these models are conducted using Abaqus/Explicit software. The numerical results of a finite element analysis are validated by comparison with data of theoretical analysis. The results show that the radial stiffness is not uniform along the longitudinal direction of the stent. When the braiding angle increases from 30° to 75°, the minimum radial deformation decreases from 0.85 mm to 0.0325 mm (at a pressure of 500 Pa, for 24 braided wires). When the wire diameter increases from 0.026 mm to 0.052 mm, the minimum radial deformation decreases from 0.65 mm to 0.055 mm (at a pressure of 500 Pa and a braiding angle of 60°, for 24 braided wires). Frictions don't affect stent diameter and its axial length when braided stent is crimping, but the friction must be considered when it is related to the radial pressure required for compression the braided stent. Compared with commonly used intracranial stents, a braided stent with geometrical parameters close to PED stent has a smaller radial stiffness but a considerably greater longitudinal flexibility. The results of this analysis of braided stents can help in the design and selection of flow diverter stents for clinical treatment of cerebral aneurysms.

  10. Structural analysis of two different stent configurations.

    PubMed

    Simão, M; Ferreira, J M; Mora-Rodriguez, J; Ramos, H M

    2017-06-01

    Two different stent configurations (i.e. the well known Palmaz-Schatz (PS) and a new stent configuration) are mechanically investigated. A finite element model was used to study the two geometries under combining loads and a computational fluid dynamic model based on fluid structure interaction was developed investigating the plaque and the artery wall reactions in a stented arterial segment. These models determine the stress and displacement fields of the two stents under internal pressure conditions. Results suggested that stent designs cause alterations in vascular anatomy that adversely affect arterial stress distributions within the wall, which have impact in the vessel responses such as the restenosis. The hemodynamic analysis shows the use of new stent geometry suggests better biofluid mechanical response such as the deformation and the progressive amount of plaque growth.

  11. Systematic review and meta-analysis of metal versus plastic stents for preoperative biliary drainage in resectable periampullary or pancreatic head tumors.

    PubMed

    Crippa, S; Cirocchi, R; Partelli, S; Petrone, M C; Muffatti, F; Renzi, C; Falconi, M; Arcidiacono, P G

    2016-09-01

    Preoperative biliary drainage (PBD) with stenting increases complications compared with surgery without PBD. Metallic stents are considered superior to plastic stents when considering stent-related complications. Aim of the present systematic review and meta-analysis is to compare the rate of endoscopic re-intervention before surgery and postoperative outcomes of metal versus plastic stents in patients with resectable periampullary or pancreatic head neoplasms. We conducted a bibliographic research using the National Library of Medicine's PubMed database, including both randomized controlled trials (RCTs) and non-RCTs. Quantitative synthesis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Statistical heterogeneity was assessed using the I(2) tests. One RCT and four non-RCTs were selected, including 704 patients. Of these, 202 patients (29.5%) were treated with metal stents and 502 (70.5%) with plastic stents. The majority of patients (86.4%) had pancreatic cancer. The rate of endoscopic re-intervention after preoperative biliary drainage was significantly lower in the metal stent (3.4%) than in the plastic stent (14.8%) group (p < 0.0001). The rate of postoperative pancreatic fistula was significantly lower in the meta stent group as well (5.1% versus 11.8%, p = 0.04). The rate of post-operative surgical complications and of - post-operative mortality did not differ between the two groups. Although the present systematic review and meta-analysis demonstrates that metal stent are more effective than plastic stents for PBD in patients with resectable periampullary tumors, randomized controlled trials are needed in order to confirm these data with a higher level of evidence. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. [Tracheobronchial stents: a retrospective analysis of indications, results and in particular complications].

    PubMed

    Tonn, H; Mall, W; Schneider, K-D; Schönhofer, B

    2008-10-01

    Tracheobronchial stents are inserted mainly in cases of malignant and benign airway stenosis. Further indications are esophago-tracheal fistulas, mediastinal fistulas and tracheomalacia. A retrospective analysis was conducted on patients' records, information provided by the general practitioners and relatives of the patients from July 1993 to December 2006 in the Department of Pneumology of the Heidehaus Hospital Hannover (since 6/05 Department of Pneumology and Internal Intensive Care Medicine, Oststadt-Heidehaus Hospital). During the observation period of 13 years a total of 269 stents (177 permanent, 92 temporary) were implanted in 207 patients (1.3 stents per patient). The vast majority of patients (173/207) suffered from an underlying malignancy. About half of the stents were deployed in the trachea. The median length of placement was 116 days in patients with malignancies and 313 days in patients with benign diseases. In about 40 % of the patients notable complications were observed which were directly or indirectly associated with the stents. These findings show the importance of a critical indication for stent implantation. In benign diseases a stent can remain for years inside the tracheobronchial system, if it is well tolerated in the beginning. In malignant diseases the result depends decisively on the stage of the tumour: has the stent been implanted before any other tumour therapy is started or is it an end-stage tumor with no other therapeutic option? In general, complications of stents occur quite frequently. The analysis of stent data leads to some aspects for the prevention of stent-related complications. There should be a strict indication and appropriate choice of stent material. Nevertheless, there remains an ethical dilemma in patients with end-stage disease as to whether to implant a stent or to do nothing against the tumor, because the benefit immediately after stent insertion vanishes with progression of the tumour, so causing extra complications.

  13. Time Sequence Evaluation of Biliary Stent Occlusion by Dissection Analysis of Retrieved Stents.

    PubMed

    Kwon, Chang-Il; Gromski, Mark A; Sherman, Stuart; Easler, Jeffrey J; El Hajj, Ihab I; Watkins, James; Fogel, Evan L; McHenry, Lee; Lehman, Glen A

    2016-08-01

    Multiple factors can affect the occlusion of plastic stents. Previous data demonstrate that side holes may induce more biofilm formation probably via microturbulence and bile flow disturbances that could lead to occlusion. These results, however, have not been replicated in subsequent clinical studies with different methods. The objective of this study is to evaluate the physical characteristics of plastic stent occlusion over time. This is a plastic stent sequential analysis study. Biliary stents removed via ERCP from February 24, 2015, to June 2, 2015, were included. One hundred and forty-eight retrieved straight-type plastic stents were longitudinally cut by a custom-made cutting device. These dissected stents were then evaluated in detail with regard to the location of stent occlusion and the stent patency period. Location of stent occlusive debris was the primary outcome in this study. Biofilm formations and occlusions by debris were sequentially but separately tallied. Biofilm formations were initially seen around the side hole areas within 30 days and spread to the entire stent by 60 days. Then, occlusion process by debris was mainly initiated by 80 days and progressed to full occlusion by median of 90 days. Although some occlusions were also observed around the side hole areas within 30 days, affected areas were more widely observed after biofilm formation. This study is the first to attempt to describe the distribution of stent occlusions over time. These observations may help guide future stent development.

  14. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    PubMed

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  15. Scanning Electron Microscopic Features of Nasolacrimal Silastic Stents Retained for Prolong Durations Following Dacryocystorhinostomy.

    PubMed

    Ali, Mohammad Javed; Baig, Farhana; Lakshman, Mekala; Naik, Milind N

    2016-01-01

    The aims of this study were to examine the scanning electron microscopic features of silastic nasolacrimal duct stents retained for long durations following a dacryocystorhinostomy. A prospective interventional study was performed on stents retrieved from patients who were lost to follow up after a dacryocystorhinostomy with Crawford stent insertion. Long duration was defined as stents retrieved at a minimum of 1 year following a dacryocystorhinostomy. None of the patients had any evidence of postoperative infection. After removal, the stent segments were subjected to biofilm and physical deposit analysis using standard protocols of scanning electron microscopy. These stent segments were compared against sterile stents which acted as controls. A total of 7 stents were studied. Five were consecutive patient samples, and 2 were sterile stents. All the 5 stents were retrieved from patients who were lost to follow up for a minimum of 12 months following surgery. The mean duration of intubation at retrieval was 21 months. All the stents demonstrated evidence of biofilm formation and physical deposits. However, as the duration of retention increased, the deposits and biofilms were noted to be progressively denser, multilayered and extensive. Certain areas demonstrated thick biofilm integration with the deposits. Polymicrobial communities were noted within the exopolysaccharide matrix. This is the first study to exclusively report on scanning electron microscopic features of lacrimal stents retained for long durations. Further studies on physical elements within the deposits and protein analysis would provide more insights into stent-tissue interactions.

  16. [Proposed model of vascular trauma by mean of mechanical characterization of endovascular prostheses (stents) based on structural analysis by FEA].

    PubMed

    Bustamante, John; Uribe, Pablo; Sosa, Mauricio; Valencia, Raúl

    2016-01-01

    The accumulated evidence on angioplasty techniques with stents has raised a controversy about the factors that influence the final vascular response. Indeed, several studies have shown there might be re-stenosis between 30% to 40% about 6 months after placement, relating to the design of the device as one of the main causes. This paper proposes the functional characterization of endovascular stents, analyzing its mechanical influence in the vascular system and predicting implicit traumatic factors in the vessel. A structural analysis was made for several computational models of endovascular stents using Finite Element Analysis in order to predict the mechanical behavior and the vascular trauma. In this way, the stents were considered as tubular devices composed of multiple links under radial pressure loads, reflecting stress concentration effects. The analysis allowed to visualize how the geometry of stents is adjusted under several load conditions, in order to obtain the response of "solid-solid" interaction between the stent and the arterial wall. Thus, an analysis was performed in order to calculate stress, and a conceptual model that explains its mechanical impact on the stent-vessel interaction, was raised, to infer on the functionality from the design of the devices. The proposed conceptual model allows to determine the relationship between the conditions of mechanical interaction of the stents, and warns about the effects in what would be the operation of the device on the vascular environment. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  17. Metallic ureteral stents in malignant ureteral obstruction: short-term results and radiological features predicting stent failure in patients with non-urological malignancies.

    PubMed

    Chow, Po-Ming; Hsu, Jui-Shan; Wang, Shuo-Meng; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liu, Kao-Lang

    2014-06-01

    To provide short-term result of the metallic ureteral stent in patients with malignant ureteral obstruction and identify radiological findings predicting stent failure. The records of all patients with non-urological malignant diseases who have received metallic ureteral stents from July 2009 to March 2012 for ureteral obstruction were reviewed. Stent failure was detected by clinical symptoms and imaging studies. Survival analysis was used to estimate patency rates and factors predicting stent failure. A total of 74 patients with 130 attempts of stent insertion were included. A total of 113 (86.9 %) stents were inserted successfully and 103 (91.2 %) achieved primary patency. After excluding cases without sufficient imaging data, 94 stents were included in the survival analysis. The median functional duration of the 94 stents was 6.2 months (range 3-476 days). Obstruction in abdominal ureter (p = 0.0279) and lymphatic metastasis around ureter (p = 0.0398) were risk factors for stent failure. The median functional durations of the stents for abdominal and pelvic obstructions were 4.5 months (range 3-263 days) and 6.5 months (range 4-476 days), respectively. The median durations of the stents with and without lymphatic metastasis were 5.3 months (range 4-398 days) and 7.8 months (range 31-476 days), respectively. Metallic ureteral stents are effective and safe in relieving ureteral obstructions resulting from non-urological malignancies, and abdominal ureteral obstruction and lymphatic metastasis around ureter were associated with shorter functional duration.

  18. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis

    PubMed Central

    Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-01-01

    Objectives To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. PMID:25378023

  19. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    PubMed

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  20. Role of Esophageal Metal Stents Placement and Combination Therapy in Inoperable Esophageal Carcinoma: A Systematic Review and Meta-analysis.

    PubMed

    Lai, Andrew; Lipka, Seth; Kumar, Ambuj; Sethi, Sajiv; Bromberg, David; Li, Nanxing; Shen, Huafeng; Stefaniwsky, Lilia; Brady, Patrick

    2018-04-01

    More than 50% of patients with esophageal cancer already have inoperable disease at the time of diagnosis. Controversy surrounds the outcomes of patients with advanced esophageal cancer who receive palliative care by either stent alone or stent plus an additional modality. We set out to perform a systematic review and meta-analysis of studies assessing the use of metal stents as treatment options for symptomatic improvement, survival, and adverse events. We searched Embase, MEDLINE, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception until January 14, 2016, as well as other databases for randomized controlled trials (RCTs) comparing esophageal stent versus either esophageal stent plus brachytherapy, radiotherapy, or chemotherapy. For quality assurance purposes throughout the systematic review, multiple independent extractions were performed, and the process was executed as per the standards of the Cochrane collaboration. Primary outcomes were mean change in dysphagia score, overall survival, and quality of life. Secondary outcomes were adverse events including fever, severe pain, aspiration, fistula, stent migration, perforation, and restenosis. Eight RCTs enrolling 732 patients were included with three distinct comparisons: stents combination therapy vs stents alone (5 studies, n = 417), stents alone versus brachytherapy alone (2 studies, n = 274), and stents + brachytherapy vs brachytherapy alone (1 study, n = 41). Stents combination therapy was defined as stents plus radiotherapy, chemotherapy, or both. Mean change in dysphagia scores favored stents combination therapy versus stents alone, and the effect was seen in patients surviving longer than 3 months. Stents combination therapy was also associated with a more favorable overall survival. The risks of stent migration, aspiration pneumonia, and restenosis were lower in the stents combination group compared to stents alone, while the risks of severe pain, hemorrhage, and fistula formation were higher. Changes in dysphagia scores and overall survival did not differ significantly in the brachytherapy-alone vs stents-alone comparison. The risk of fistula formation and hemorrhage were higher in the stents-alone group, while the risk of perforation was lower, compared to brachytherapy alone. Quality of life improvements were seen in all treatment groups, but were not pooled in analysis due to differing methods of measurement. While there appears to be no immediate short-term differences, those who live longer than 3 months experience a significant improvement in dysphagia score using a stents combination therapy approach vs stents alone. The combination therapy significantly improves the overall survival as well as showed improvements in quality of life scores. Larger randomized controlled trials are needed to assess improvements in dysphagia score, overall survival, quality of life, and adverse events.

  1. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José-Ramón; Masotti, Mónica; Zueco, Javier; Melgares, Rafael; Mainar, Vicente; Moreno, Raul; Domínguez, Antonio; Sanchís, Juan; Bethencourt, Armando; Moreu, José; Cequier, Angel; Martí, Vicens; Otaegui, Imanol; Bastante, Teresa; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Cárdenas, Alberto; Fernández, Cristina

    2016-07-01

    Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22±0.5 versus 2.38±0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03±0.7 versus 2.36±0.6 mm, P<0.001) and diameter stenosis (23±22 versus 13±17%, P<0.001) were poorer in patients with DES-ISR. Results were consistent in the in-segment and in-lesion analyses. On multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR. Finally, at 1-year clinical follow-up (100% of patients), mortality (2.6 versus 0%, P<0.01) and need for target vessel revascularization (8 versus 2%, P=0.03) were higher in the DES-ISR group. This patient-level pooled analysis of the RIBS IV and RIBS V randomized clinical trials suggests that EES provide favorable outcomes in patients with ISR. However, the results of EES are less satisfactory in patients with DES-ISR than in those with bare-metal stent ISR. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01239953 and NCT01239940. © 2016 American Heart Association, Inc.

  2. Food impaction after expandable metal stent placement: experience in 1,360 patients with esophageal and upper gastrointestinal tract obstruction.

    PubMed

    Song, Min; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Jung, Hwoon-Yong; Kim, Jong-Hoon; Kim, Sung-Bae

    2011-09-01

    To retrospectively evaluate the incidence, predictive factors, and interventional management of food impaction after expandable metallic stent placement in patients with obstruction of the esophagus or upper gastrointestinal tract caused by benign or malignant disease. Between March 1993 and March 2010, 1,360 patients (1,029 men, 331 women; age range, 21-89 y; mean age, 61 y) underwent fluoroscopically guided stent placement for dysphagia caused by esophageal or gastrointestinal tract strictures. Five types of covered expandable metal stents were used, including four types of esophageal stents (types A-D) and one type of gastroduodenal stent (type E), with types A, B, C, D, and E stents used in 180, 60, 90, 432, and 598 patients, respectively. Multivariate analysis was performed to evaluate factors predictive of food impaction. Food impaction occurred in 41 of 1,360 patients (3.0%). The food impaction rates for types A, B, C, D, and E stents were 0.6%, 1.7%, 1.1%, 3.2%, and 4.0%, respectively. Multivariate analysis showed that stent length was an independent predictor of food impaction (odds ratio, 0.839; P = .012). Of the 41 patients with food impaction, 23 underwent endoscopic management, 12 underwent fluoroscopically guided management, and six did not require management because impacted food spontaneously passed through the stent. The overall food impaction rate was 3.0%, with multiple logistic regression analysis showing that shorter stent length was the only significant predictor of food impaction. Food impaction can be managed by endoscopic or fluoroscopically guided removal or placement of a second stent. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  3. A systematic review of the reporting of Data Monitoring Committees' roles, interim analysis and early termination in pediatric clinical trials

    PubMed Central

    2009-01-01

    Background Decisions about interim analysis and early stopping of clinical trials, as based on recommendations of Data Monitoring Committees (DMCs), have far reaching consequences for the scientific validity and clinical impact of a trial. Our aim was to evaluate the frequency and quality of the reporting on DMC composition and roles, interim analysis and early termination in pediatric trials. Methods We conducted a systematic review of randomized controlled clinical trials published from 2005 to 2007 in a sample of four general and four pediatric journals. We used full-text databases to identify trials which reported on DMCs, interim analysis or early termination, and included children or adolescents. Information was extracted on general trial characteristics, risk of bias, and a set of parameters regarding DMC composition and roles, interim analysis and early termination. Results 110 of the 648 pediatric trials in this sample (17%) reported on DMC or interim analysis or early stopping, and were included; 68 from general and 42 from pediatric journals. The presence of DMCs was reported in 89 of the 110 included trials (81%); 62 papers, including 46 of the 89 that reported on DMCs (52%), also presented information about interim analysis. No paper adequately reported all DMC parameters, and nine (15%) reported all interim analysis details. Of 32 trials which terminated early, 22 (69%) did not report predefined stopping guidelines and 15 (47%) did not provide information on statistical monitoring methods. Conclusions Reporting on DMC composition and roles, on interim analysis results and on early termination of pediatric trials is incomplete and heterogeneous. We propose a minimal set of reporting parameters that will allow the reader to assess the validity of trial results. PMID:20003383

  4. Spontaneous passage of ureteral stones in patients with indwelling ureteral stents.

    PubMed

    Baumgarten, Lee; Desai, Anuj; Shipman, Scott; Eun, Daniel D; Pontari, Michel A; Mydlo, Jack H; Reese, Adam C

    2017-10-01

    To determine rates of spontaneous ureteral stone passage in patients with indwelling ureteral stents, and to identify factors associated with the spontaneous passage of stones while a ureteral stent is in place. From our institutional database, we identified patients who underwent ureteroscopic procedures for stone disease between January 1, 2013 and March 1, 2015. We compared the rates of spontaneous stone passage between patients who had previously undergone ureteral stent placement and those who had not. In patients with indwelling stents, multivariate logistic regression was performed to identify factors associated with spontaneous stone passage. A total of 194 patients met inclusion criteria. Spontaneous stone passage rates were similar in the stented (17/119, 14%) and non-stented (15/75, 20%) groups (p = 0.30). In bivariate analysis of stented patients, smaller stone size (p < 0.001) and distal stone location (p = 0.01) were significantly associated with spontaneous stone passage. Multivariate logistic regression analysis of stented patients showed that only small stone size was significantly associated with the likelihood of stone passage (p = 0.01), whereas stent duration, stone location, and stone laterality were not. A small, but clinically significant percentage of ureteral stones pass spontaneously with a ureteral stent in place. Small stone size is associated with an increased likelihood of spontaneous passage in patients with indwelling stents. These findings may help to identify patients who can potentially avoid additional surgical procedures for definitive stone removal after ureteral stent placement.

  5. Cost-effectiveness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitäts Trial (BASKET): an 18-month analysis.

    PubMed

    Brunner-La Rocca, Hans Peter; Kaiser, Christoph; Bernheim, Alain; Zellweger, Michael J; Jeger, Raban; Buser, Peter T; Osswald, Stefan; Pfisterer, Matthias

    2007-11-03

    Our aim was to determine whether drug-eluting stents are good value for money in long-term, everyday practice. We did an 18-month cost-effectiveness analysis of the Basel Stent KostenEffektivitäts Trial (BASKET), which randomised 826 patients 2:1 to drug-eluting stents (n=545) or to bare-metal stents (281). We used non-parametric bootstrap techniques to determine incremental cost-effectiveness ratios (ICERs) of drug-eluting versus bare-metal stents, to compare low-risk (> or =3.0 mm stents in native vessels; n=558, 68%) and high-risk patients (<3.0 mm stents/bypass graft stenting; n=268, 32%), and to do sensitivity analyses by altering costs and event rates in the whole study sample and in predefined subgroups. Quality-adjusted life-years (QALYs) were assessed by EQ-5D questionnaire (available in 703/826 patients). Overall costs were higher for patients with drug-eluting stents than in those with bare-metal stents (11,808 euros [SD 400] per patient with drug-eluting stents and 10,450 euros [592] per patient with bare-metal stents, mean difference 1358 euros [717], p<0.0001), due to higher stent costs. We calculated an ICER of 64,732 euros to prevent one major adverse cardiac event, and of 40,467 euros per QALY gained. Stent costs, number of events, and QALYs affected ICERs most, but unrealistic alterations would have been required to achieve acceptable cost-effectiveness. In low-risk patients, the probability of drug-eluting stents achieving an arbitrary ICER of 10,000 euros or less to prevent one major adverse cardiac event was 0.016; by contrast, it was 0.874 in high-risk patients. If used in all patients, drug-eluting stents are not good value for money, even if prices were substantially reduced. Drug-eluting stents are cost effective in patients needing small vessel or bypass graft stenting, but not in those who require large native vessel stenting.

  6. Provisional vs. two-stent technique for unprotected left main coronary artery disease after ten years follow up: A propensity matched analysis.

    PubMed

    D'Ascenzo, Fabrizio; Iannaccone, Mario; Giordana, Francesca; Chieffo, Alaide; Connor, Stephen O; Napp, L Christian; Chandran, SujaySubash; de la Torre Hernández, José María; Chen, Shao-Liang; Varbella, Ferdinando; Omedè, Pierluigi; Taha, Salma; Meliga, Emanuele; Kawamoto, Hiroyoshi; Montefusco, Antonio; Chong, Mervyn; Garot, Philippe; Sin, Lin; Gasparetto, Valeria; Abdirashid, Mohamed; Cerrato, Enrico; Biondi-Zoccai, Giuseppe; Gaita, Fiorenzo; Escaned, Javier; Hiddick Smith, David; Lefèvre, Thierry; Colombo, Antonio; Sheiban, Imad; Moretti, Claudio

    2016-05-15

    There is uncertainty on which stenting approach confers the best long-term outlook for unprotected left main (ULM) bifurcation disease. This is a non-randomized, retrospective study including all consecutive patients with 50% stenosis of the left main involving at least 1 of the arteries stemming from the left main treated with drug-eluting stents (DES) in 9 European centers between 2002 and 2004. Patients were divided into two groups: those treated with provisional stentings vs. those treated with two stent strategy. The outcomes of interest were 10-year rates of target lesion revascularization (TLR), major adverse cardiac events (MACE), and their components (cardiovascular death, myocardial infarction [MI], or repeat revascularization), along with stent thrombosis (ST). A total of 285 patients were included, 178 (62.5%) in the provisional stenting group and 87 (37.5%) in the two stent group. After 10 years, no differences in TLR were found at unadjusted analysis (19% vs 25%, p>0.05) nor after propensity score matching (25% vs 28%, p>0.05). Similar rates of MACE (60% vs 66%, p>0.05), death (34% vs 43%, p>0.05), MI (9% vs 14%, p>0.05) and ST were also disclosed at propensity-based analysis. Even after 10 year follow-up, patients treated with provisional stenting on left main showed comparable rates of target lesion revascularization compared to two stent strategy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Treatment of benign and malignant tracheobronchial obstruction with metal wire stents: experience with a balloon-expandable and a self-expandable stent type.

    PubMed

    Rieger, Johannes; Hautmann, Hubert; Linsenmaier, Ulrich; Weber, Cristoph; Treitl, Markus; Huber, Rudolf Maria; Pfeifer, Klaus-Jürgen

    2004-01-01

    Over the last few years various types of metal wire stents have been increasingly employed in the treatment of both malignant and benign tracheobronchial obstruction. To date, however, few studies have investigated the in vivo properties of different stent types. We implanted 26 balloon-expandable tantalum Strecker stents (18 patients) and 18 self-expandable Wallstents (16 patients) into the tracheobronchial system of 30 patients with combined stenting in 4 patients. Mean age was 51 years (range: 0.5-79 years). Malignant disease was present in 23 patients, benign disease in seven patients. Both patients and individual stents were monitored clinically and radiographically. The probability of stents remaining within the tracheobronchial system, and of their remaining undislocated and uncompressed was calculated using Kaplan-Meier analysis for both stent types. Average stent follow-up time was 112 days until explantation and 115 days until patients' death or discharge. Kaplan-Meier analysis revealed a higher probability for the Wallstent to remain within the tracheobronchial system. Dislocation and compression occurred more rarely. Explantation, however, if desired, was more difficult compared to the Strecker stent. The Wallstent also led to the formation of granulation tissue, especially at the proximal stent end, frequently requiring reintervention. Both stent types proved to be effective therapeutic options in the management of obstructive tracheobronchial disease. The mechanical properties of the Strecker stent seem to be less favorable compared to the Wallstent but removal is easy. For benign disease, however, the Wallstent reveals limitations due to significant side effects.

  8. Biomechanical analysis on stent materials used as cardiovascular implants

    NASA Astrophysics Data System (ADS)

    Kumar, Vasantha; Ramesha, C. M.; Sajjan, Sudheer S.

    2018-04-01

    Atherosclerosis is the most common cause of death in the world, accounting for 48% of all deaths in the world. Atherosclerosis, also known as coronary artery disease occurs when excess cholesterol attaches itself to the walls of blood vessels. Coronary stent implantation is one of the most important procedures to treating coronary artery disease such atherosclerosis. Due to its efficiency, flexibility and simplicity, the use of coronary stents procedures has increased rapidly. In order to have better output of stent implantation, it is needed to study and analyze the biomechanical behavior of this device before manufacturing and put into use. Biomaterials are commonly used for medical application in cardiovascular stent implantation. A biomaterial is a non-viable material used as medical implant, so it is intended to interact with biological system. In this paper, an explicit dynamic analysis is used for analyzing the biomechanical behavior of cardiovascular stent by using finite element analysis tool, ABAQUS 6.10. Results showed that a best suitable biomaterial for cardiovascular stent implants, which exhibits an outstanding biocompatibility and biomechanical characteristics will be aimed at which will be quite useful to the human beings worldwide.

  9. Self-expanding Y stents in the treatment of central airway stenosis: a retrospective analysis.

    PubMed

    Gompelmann, Daniela; Eberhardt, Ralf; Schuhmann, Maren; Heussel, Claus P; Herth, Felix J F

    2013-10-01

    Central airway obstruction (CAO) is a life-threatening situation. Stent insertion re-establishes patency of the central airways. Self-expanding metallic Y stents have been available since 2005, widening the spectrum of interventional bronchoscopic techniques. Retrospective analysis of all patients treated for CAO with a self-expanding metallic Y stent at the Thoraxklinik Heidelberg between May 2005 and January 2009. A total of 43 patients aged 26-81 had a metallic Y stent inserted endoscopically for the treatment of CAO; 39 of these patients (90.7%) had CAO due to malignant disease, four patients (9.3%) due to benign disease. In all 43 patients, the Y stent was deployed without any complications. A longitudinal follow up was possible in 32 of the 43 patients. The stents remained in situ for an average of 107.1 days (range 1-640 days). In 29 patients with malignant CAO the stenosis was successfully overcome with a Y stent; 11 of these patients died within 6 weeks following stent insertion. On follow up the remaining 18 patients showed immediate improvement of dyspnoea. Eight out of the 18 patients (44.4%) tolerated the stent without problems, two (11.1%) required further stenting, six (33.3%) had complications such as increased secretions, cough, dyspnoea or granulation tissue formation. The stent was removed in one patient (5.6%) due to increased secretions, and in another (5.6%) as the stent was no longer required due to successful tumour-specific therapy. Placement of Y stents in symptomatic CAO allows for quick relief of symptoms. Severe complications are rare. Stent removal is possible after successful treatment of the primary tumour. However, the prognostic indicator for survival is the underlying malignancy.

  10. Investigation of adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents in the iliac vein: insights into developing a better iliac vein stent.

    PubMed

    Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-06-01

    We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.

  11. [The Predictive Factors of Stent Failure in the Treatment of Malignant Extrinsc Ureteral Obstruction Using Internal Ureteral Stents].

    PubMed

    Matsuura, Hiroshi; Arase, Shigeki; Hori, Yasuhide; Tochigi, Hiromi

    2017-12-01

    In this study, we retrospectively reviewed the experiences at our single institute in the treatment of malignant extrinsic ureteral obstruction (MUO) using ureteral stents to investigate the clinical outcomes and the predictive factors of stent failure. In 52 ureters of 38 patients who had radiologically significant hydronephrosis due to MUO, internal ureteral stents (The BARD(R) INLAY(TM) ureteral stent set) were inserted. The median follow-up interval after the initial stent insertion was 124.5 days (4-1,120). Stent failure occurred in 8 ureters (15.4%) of the 7 patients. The median interval from the first stent insertion to stent failure was 88 days (1-468). A Cox regression multivariate analysis showed that the significant predictors of stent failure were bladder invasion. Based on the possibility of stent failure, the adaptation of the internal ureteral stent placement should be considered especially in a patient with MUO combined with bladder invasion.

  12. Carotid artery stenting in the SPACE and EVA-3S trials: analysis and update.

    PubMed

    Mansour, M Ashraf

    2008-03-01

    Carotid artery stenting is an alternative to carotid endarterectomy. Although the stroke and mortality rates after stenting are low, it is yet to be proved that stenting is superior or equal to endarterectomy in low-risk symptomatic and asymptomatic patients. A summary of the results of 2 recent trials comparing carotid stenting with carotid endarterectomy, SPACE, and EVA-3S, is presented herein. Both trials failed to prove noninferiority of carotid stenting compared with carotid endarterectomy.

  13. Cost utility analysis of endoscopic biliary stent in unresectable hilar cholangiocarcinoma: decision analytic modeling approach.

    PubMed

    Sangchan, Apichat; Chaiyakunapruk, Nathorn; Supakankunti, Siripen; Pugkhem, Ake; Mairiang, Pisaln

    2014-01-01

    Endoscopic biliary drainage using metal and plastic stent in unresectable hilar cholangiocarcinoma (HCA) is widely used but little is known about their cost-effectiveness. This study evaluated the cost-utility of endoscopic metal and plastic stent drainage in unresectable complex, Bismuth type II-IV, HCA patients. Decision analytic model, Markov model, was used to evaluate cost and quality-adjusted life year (QALY) of endoscopic biliary drainage in unresectable HCA. Costs of treatment and utilities of each Markov state were retrieved from hospital charges and unresectable HCA patients from tertiary care hospital in Thailand, respectively. Transition probabilities were derived from international literature. Base case analyses and sensitivity analyses were performed. Under the base-case analysis, metal stent is more effective but more expensive than plastic stent. An incremental cost per additional QALY gained is 192,650 baht (US$ 6,318). From probabilistic sensitivity analysis, at the willingness to pay threshold of one and three times GDP per capita or 158,000 baht (US$ 5,182) and 474,000 baht (US$ 15,546), the probability of metal stent being cost-effective is 26.4% and 99.8%, respectively. Based on the WHO recommendation regarding the cost-effectiveness threshold criteria, endoscopic metal stent drainage is cost-effective compared to plastic stent in unresectable complex HCA.

  14. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.

    PubMed

    Inoue, Tadahisa; Naitoh, Itaru; Okumura, Fumihiro; Ozeki, Takanori; Anbe, Kaiki; Iwasaki, Hiroyasu; Nishie, Hirotada; Mizushima, Takashi; Sano, Hitoshi; Nakazawa, Takahiro; Yoneda, Masashi; Joh, Takashi

    2016-11-01

    Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent. © 2016 Japan Gastroenterological Endoscopy Society.

  15. Mechanical Interaction of an Expanding Coiled Stent with a Plaque-Containing Arterial Wall: A Finite Element Analysis.

    PubMed

    Welch, Tré R; Eberhart, Robert C; Banerjee, Subhash; Chuong, Cheng-Jen

    2016-03-01

    Wall injury is observed during stent expansion within atherosclerotic arteries, related in part to stimulation of the inflammatory process. Wall stress and strain induced by stent expansion can be closely examined by finite element analysis (FEA), thus shedding light on procedure-induced sources of inflammation. The purpose of this work was to use FEA to examine the interaction of a coiled polymer stent with a plaque-containing arterial wall during stent expansion. An asymmetric fibrotic plaque-containing arterial wall model was created from intravascular ultrasound (IVUS) images of a diseased artery. A 3D model for a coil stent at unexpanded state was generated in SolidWorks. They were imported into ANSYS for FEA of combined stent expansion and fibrotic plaque-distortion. We simulated the stent expansion in the plaqued lumen by increasing balloon pressure from 0 to 12 atm in 1 atm step. At increasing pressure, we examined how the expanding stent exerts forces on the fibrotic plaque and vascular wall components, and how the latter collectively resist and balance the expansive forces from the stent. Results show the expanding coiled stent creates high stresses within the plaque and the surrounding fibrotic capsule. Lower stresses were observed in adjacent medial and adventitial layers. High principal strains were observed in plaque and fibrotic capsule. The results suggest fibrotic capsule rupture might occur at localized regions. The FEA/IVUS method can be adapted for routine examination of the effects of the expansion of selected furled stents against IVUS-reconstructed diseased vessels, to improve stent deployment practices.

  16. Direct Primary or Secondary Percutaneous Ureteral Stenting: What Is the Most Compliant Option in Patients with Malignant Ureteral Obstructions?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrafiello, Gianpaolo, E-mail: gcarraf@tin.it; Lagana, Domenico; Lumia, Domenico

    2007-09-15

    The objective of this study was to analyze three ureteral stenting techniques in patients with malignant ureteral obstructions, considering the indications, techniques, procedural costs, and complications. In the period between June 2003 and June 2006, 45 patients with bilateral malignant ureteral obstructions were evaluated (24 males, 21 females; average age, 68.3; range, 42-87). All of the patients were treated with ureteral stenting: 30 (mild strictures) with direct stenting (insertion of the stent without predilation), 30 (moderate/severe strictures) with primary stenting (insertion of the stent after predilation in a one-stage procedure), and 30 (mild/moderate/severe strictures with infection) with secondary stenting (insertionmore » of the stent after predilation and 2-3 days after nephrostomy). The incidence of complications and procedural costs were compared by a statistical analysis. The primary technical success rate was 98.89%. We did not observe any major complications. The minor complication rate was 11.1%. The incidence of complications for the various techniques was not statistically significantly. The statistical analysis of costs demonstrated that the average cost of secondary stenting ( Euro 637; SD, Euro 115) was significantly higher than that of procedures which involved direct or primary stenting ( Euro 560; SD, Euro 108). We conclude that one-step stenting (direct or primary) is a valid option to secondary stenting in correctly selected patients, owing to the fact that when the procedure is performed by expert interventional radiologists there are high technical success rates, low complication rates, and a reduction in costs.« less

  17. Percutaneous stent placement for the treatment of malignant biliary obstruction: nitinol versus elgiloy stents.

    PubMed

    Zurstrassen, Charles Edouard; Bitencourt, Almir Galvão Vieira; Guimaraes, Marcos Duarte; Cavalcante, Aline Cristine Barbosa Santos; Tyng, Chiang Jeng; Amoedo, Mauricio Kauark; Matsushita Junior, João Paulo Kawaoka; Szklaruk, Janio; Marchiori, Edson; Chojniak, Rubens

    2017-01-01

    This study aimed to compare two self-expanding stents, a nitinol stent and an elgiloy stent, both placed percutaneously, in terms of their efficacy in palliating inoperable malignant biliary obstruction. We retrospectively investigated 99 patients with unresectable malignant biliary obstruction treated with percutaneous placement of a self-expanding metallic stent at our institution between May 2007 and January 2010. Serum bilirubin and liver enzyme levels were measured before and 30 days after stenting. For all procedures using elgiloy or nitinol stents, stent occlusion and patient survival rates were calculated using Kaplan-Meyer analysis. All of the patients showed clinical improvement after stent placement, with no difference between the two groups. In both groups, the occlusion-free survival rate was 67% at 30 days, 37% at 90 days, 25% at 180 days, and 10% at 360 days, with no significant difference in relation to the type of stent. The two stents evaluated showed comparable efficacy for the percutaneous treatment of unresectable biliary malignancy, with good clinical results.

  18. A retrospective analysis of early and late outcome of biodegradable stent placement in the management of refractory anastomotic colorectal strictures.

    PubMed

    Repici, A; Pagano, N; Rando, G; Carlino, A; Vitetta, E; Ferrara, E; Strangio, G; Zullo, A; Hassan, C

    2013-07-01

    Benign colorectal strictures are treated conventionally by endoscopic dilation. Experience using SEMS for benign colonic strictures is limited, and outcomes to date have been disappointing. Refractory colorectal strictures remain challenging to be treated with surgery. Polydioxanone-based stent are biodegradable (BD) stent CE approved for esophageal strictures. This study was designed to investigate retrospectively the safety and the efficacy of these stents for the management of strictures refractory to multiple sessions of dilation. Patients with postsurgical benign strictures located within 20 cm from anal verge, refractory to mechanical or pneumatic dilation (at least 3 sessions) were included in this analysis. Clinical success was defined as the absence of occlusive symptoms and the ability to pass through the stricture with a regular size colonoscope. All patients were predilated before stent placement. Stents were released under fluoroscopic control. All patients were under stool softeners for 3 months. Follow-up was scheduled with endoscopic and fluoroscopic controls within 90 days from stent deployment and afterwards by telephone interview and/or ambulatory consultation. Eleven patients (7 males, mean age 62.3 ± 8.5 years) were included. Technical success was achieved in all the patients. Stent migration was observed in four patients within the first 2 weeks after stent placement. Stent migration was followed by recurrence of stricture and obstructive symptoms in all the cases. Among the seven patients who completed the process of stent biodegradation, five of them had complete resolution of the stricture and relief of symptoms. Two of 11 patients required surgical treatment during the follow-up period (mean 19.8 (range 42-15) months). The overall success rate of the BD stent was 45 %. This retrospective analysis of a limited number of patients demonstrated that nondedicated esophageal BD stents are associated with high risk of migration and clinical success in less than 50 % of patients. Dedicated stents with large diameter and antimigration findings could potentially improve the outcome of patients with refractory benign colorectal strictures.

  19. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    PubMed

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare-metal stents at 2-year follow-up. In randomised studies completed to date, CoCr-EES has the lowest rate of stent thrombosis within 2 years of implantation. The finding that CoCr-EES also reduced stent thrombosis compared with bare-metal stents, if confirmed in future randomised trials, represents a paradigm shift. The Cardiovascular Research Foundation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Risk factors for covered metallic stent migration in patients with distal malignant biliary obstruction due to pancreatic cancer.

    PubMed

    Nakai, Yousuke; Isayama, Hiroyuki; Kogure, Hirofumi; Hamada, Tsuyoshi; Togawa, Osamu; Ito, Yukiko; Matsubara, Saburo; Arizumi, Toshihiko; Yagioka, Hiroshi; Mizuno, Suguru; Sasaki, Takashi; Yamamoto, Natsuyo; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-09-01

    Covered metallic stents (CMSs) were developed to overcome tumor ingrowth in uncovered metallic stents (UMSs) for malignant biliary obstruction, but superiority of CMSs over UMSs is still controversial due to the high migration rate in CMS. Therefore, we conducted this retrospective analysis to clarify risk factors for stent migration, including mechanical properties of CMSs. Patients with unresectable pancreatic cancer, receiving CMS for distal malignant biliary obstruction in five tertiary care centers, were retrospectively studied. Univariate and multivariate analyses to identify prognostic factors for early (< 6 months) stent migration were performed using a proportional hazards model with death or stent occlusion without stent migration as a competing risk. Two mechanical properties were included in the analysis: axial force, the recovery force that leads to a CMS straightening, and radial force (RF), the expansion force against the stricture. Among 290 patients who received CMS placement for distal malignant biliary obstruction, stent migration rate was 15.2%. CMS migrated early (< 6 months) in 10.0% and distally in 11.7%, respectively. In the multivariate analysis, significant risk factors for early stent migration were chemotherapy (subdistribution hazard ratios [SHR] 4.46, P = 0.01), CMS with low RF (SHR 2.23, P = 0.03), and duodenal invasion (SHR 2.25, P = 0.02). CMS with low RF, chemotherapy, and duodenal invasion were associated with CMS migration from our study. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  1. Análisis Costo Efectividad del Stent Farmacológico V/S Stent no Farmacológico en Cardiopatía Isquémica en Chile.

    PubMed

    De la Puente, Catherine; Vallejos, Carlos; Velásquez, Mónica; Soto, David; Orellana, Juan

    2012-12-01

    To evaluate and compare the costs and effectiveness of two alternative stent, drug eluting stent (SF) and bare metal stent (SNF). Cost-utility analysis based on a Markov model using data from a cohort study of Hospital Las Higueras of Talcahuano, Chile. The effectiveness measure was the rate of restenosis and the time of restenosis. The effectiveness outcomes are expressed in quality-adjusted life years (QALY) gained. Costs are expressed in national currency 2011. The evaluation perspective was from the public heath budget. We model a cohort from age 63 to 80 years, life expectancy in Chile. Apply discount rate of 0, 3% and 6% for results and costs. Sensitivity analysis is performed according to the ranges of variability in costs, the utility values of the variables and transition between states. No differences in restenosis rates between the two stents, although there were differences in the time of restenosis. The incremental cost effectiveness ratio (ICER) no discount rate was CH$ 235.749 per QALY gained when using drug-eluting stent, the value below the equivalent of 1 Gross Domestic Product (PIB) per capita for 2011 in Chile. The drug-eluting stent (SF) is cost effective compared to bare metal stent (SNF). The ICER is not affected by the sensitivity analysis (variability of cost, utility ranges used, probability of restenosis). Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  2. [Finite Element Analysis of Intravascular Stent Based on ANSYS Software].

    PubMed

    Shi, Gengqiang; Song, Xiaobing

    2015-10-01

    This paper adopted UG8.0 to bulid the stent and blood vessel models. The models were then imported into the finite element analysis software ANSYS. The simulation results of ANSYS software showed that after endothelial stent implantation, the velocity of the blood was slow and the fluctuation of velocity was small, which meant the flow was relatively stable. When blood flowed through the endothelial stent, the pressure gradually became smaller, and the range of the pressure was not wide. The endothelial shear stress basically unchanged. In general, it can be concluded that the endothelial stents have little impact on the flow of blood and can fully realize its function.

  3. Overview of evidence on emergency carotid stenting in patients with acute ischemic stroke due to tandem occlusions: a systematic review and meta-analysis.

    PubMed

    Coelho, Andreia; Lobo, Miguel; Gouveia, Ricardo; Silveira, Diogo; Campos, Jacinta; Augusto, Rita; Coelho, Nuno; Canedo, Alexandra

    2018-01-23

    Endovascular intracranial thrombectomy (IT) has established itself as the standard of care in treating large-vessel anterior circulation acute ischemic stroke (AIS). However, internal carotid artery (ICA) stenosis/occlusion hampers distal access and controversy about simultaneous emergency ICA stenting ensues. The purpose of this review was to evaluate the safety of emergency ICA stenting in combination with IT for AIS with tandem occlusions. To our knowledge this is the first meta-analysis to evaluate emergency ICA stenting in tandem occlusions, combining results from studies with a control group. A systematic review and meta-analysis was conducted according to the recommendations of the Preferred Reporting Items for Systematic reviews and Meta- Analyses (PRISMA) statement. A total of 649 potentially relevant articles were initially selected. After reviewing at title or abstract level, 87 articles were read in full and 23 were included. These studies recruited 1000 patients, 220 submitted to IT with no emergency ICA stenting and 780 to IT and emergency ICA stenting. Successful revascularization (Thrombolysis in cerebral infarction scale - TICI≥2b) was achieved in 48.6-100%. Good outcome (modified Rankin scale - mRS≤2) ranged from 18.2-100%. Symptomatic intracranial haemorrhage (sICH) ranged from 0-45.7% (overall n=168; 17.2%). Mortality at 90 days ranged from 0-45.4% (overall n=114; 11.7%). Time to recanalization was significantly longer in the stenting group with an overall mean difference of 1.76 (95% Confidence Interval: 1.59-1.93). In this meta-analysis time to recanalization was significantly longer in the emergency ICA stenting group. There was no benefit from emergency stenting in parameters such as successful revascularization (TICI≥2b), clinical outcome (mRS≤2) or 90-day mortality. Data on sICH were scarce. Emergency ICA stenting appears to increase time to revascularization and increase the risk of complications with no demonstrated clinical benefit. Furthermore, no prospective, randomized controlled trials demonstrating relative efficacy and safety of concomitant ICA stenting have been published to date. Additional studies must be undertaken to define the role of angioplasty and stenting of the extracranial carotid arteries in the early management of acute stroke in tandem occlusions. Until then, we recommend that ICA stenting concommintant to thrombectomy in acute stroke patients should be avoided.

  4. Paclitaxel Drug-Eluting Stents in Peripheral Arterial Disease: A Health Technology Assessment

    PubMed Central

    2015-01-01

    Background Peripheral arterial disease is a condition in which atherosclerotic plaques partially or completely block blood flow to the legs. Although percutaneous transluminal angioplasty and metallic stenting have high immediate success rates in treating peripheral arterial disease, long-term patency and restenosis rates in long and complex lesions remain unsatisfactory. Objective The objective of this analysis was to evaluate the clinical effectiveness, safety, cost-effectiveness and budget impact of Zilver paclitaxel self-expanding drug-eluting stents for the treatment of de novo or restenotic lesions in above-the-knee peripheral arterial disease. Data Sources Literature searches were performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews. For the economic review, a search filter was applied to limit search results to economics-related literature. Data sources for the budget impact analysis included expert opinion, published literature, and Ontario administrative data. Review Methods Systematic reviews, meta-analyses, randomized controlled trials, and observational studies were included in the clinical effectiveness review, and full economic evaluations were included in the economic literature review. Studies were included if they examined the effect of Zilver paclitaxel drug-eluting stents in de novo or restenotic lesions in above-the-knee arteries. For the budget impact analysis, 3 scenarios were constructed based on different assumptions. Results One randomized controlled trial reported a significantly higher patency rate with Zilver paclitaxel drug-eluting stents for lesions ≤ 14 cm than with angioplasty or bare metal stents. One observational study showed no difference in patency rates between Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. Zilver paclitaxel drug-eluting stents were associated with a significantly higher event-free survival rate than angioplasty, but the event-free survival rate was similar for Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. No economic evaluations compared Zilver paclitaxel drug-eluting stents with bare metal stents or angioplasty for peripheral arterial disease. A budget impact analysis showed that the cost savings associated with funding of Zilver paclitaxel drug-eluting stents would be $470,000 to $640,000 per year, assuming that the use of the Zilver paclitaxel drug-eluting stent was associated with a lower risk of subsequent revascularization. Conclusions Based on evidence of low to moderate quality, Zilver paclitaxel drug-eluting stents were associated with a higher patency rate than angioplasty or bare metal stents, and with fewer adverse events than angioplasty. The effectiveness and safety of Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons were similar. PMID:26719778

  5. Newly designed plastic stent for endoscopic placement above the sphincter of Oddi in patients with malignant hilar biliary obstruction.

    PubMed

    Ishiwatari, Hirotoshi; Hayashi, Tsuyoshi; Ono, Michihiro; Sato, Tsutomu; Kato, Junji

    2013-05-01

    Plastic stent (PS) occlusion occurs as a result of bacterial adherence to the stent's inner wall. To retain the bacteriological barrier, placing a PS above the sphincter of Oddi ('inside stent') has been investigated. We designed a new PS (inside stent with thread [IT] stent) with attachable nylon thread for use as an inside stent and for easy retrieval. The present study evaluated the IT stent's technical feasibility and efficacy for malignant hilar biliary obstruction. A total of 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent placement of IT stents from August 2007 to February 2011. IT stents were placed across the strictures without sphincterotomy to achieve bilateral drainage. The overall technical success rate of the IT stent was 100% for one session. Multiple IT stents were inserted in 25 cases(two stents in 15 patients, three stents in 10 patients). No stent-related early complications occurred. The functional success rate was 92% (24/26). The rate of reintervention because of stent malfunction was 50% (13/26). In all 16 patients who underwent stent removal, IT stents were easily retrieved using the nylon thread. According to Kaplan-Meier analysis, the median stent patency period was 136 days. IT stents for endoscopic placement above the sphincter of Oddi can be used safely and effectively for malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  6. SU-E-T-115: Dose Perturbation Study of Self-Expandable Metal and Polyester Esophageal Stents in Proton Therapy Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S; Li, Z; Jalaj, S

    2014-06-01

    Purpose: This work investigates dose perturbations due to Self-expandable metal and polyester esophageal stents undergoing proton radiotherapy for esophageal cancer. Methods: Five commercially available esophageal stents made of nitinol (Evolution, Wallflex and Ultraflex), stainless steel (Z-Stent) and polyester (Polyflex) were tested. Radiochromic film (GafChromic EBT3 film, Ashland, Covington, KY) wrapped around a stent and a 12cc syringe was irradiated with 2CGE (Cobalt Gray Equivalent) of proton beam in a custom fabricated acrylic phantom. An air-hollow syringe simulates the esophagus. Results: The Z-stent created the largest dose perturbations ranges from -14.5% to 6.1% due to the steel composition. The WallFlex, Evolutionmore » and Ultraflex stents produced the dose perturbation ranges of (−9.2%∼8.6%), (−6.8%∼5.7%) and (−6.2%∼6.2%), respectively. The PolyFlex stent contains the radiopaque tungsten markers located top, middle and bottom portions. When the focal cold spots induced by the markers were excluded in the analysis, the dose perturbation range was changed from (−11.6%∼6.4%) to (−0.6%∼5.0%). Conclusion: The magnitude of dose perturbation is related to material of a metallic stent. The non-metallic stent such as PolyFlex shows relatively lower dose perturbation than metallic stents except a radiopaque marker region. Overall Evolution and Ultraflex stent appear to be less dose perturbations. The largest dose perturbations (cold spots) were located at both edges of stents in distal area for the single proton beam irradiation study. The analysis of more than two proton beam which is more typical clinical beam arrangement would be necessary to minimize the doe perturbation effect in proton ratiotherapy.« less

  7. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    PubMed

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels <3.0 mm (n=209) and type B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, p<0.001; long lesions 0.13+/-0.26 mm versus 0.43+/-0.46 mm, p=0.070; small vessels 0.17+/-0.28 mm versus 0.37+/-0.39 mm, p<0.001; B2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, p<0.001. The everolimus-eluting stent remained superior in terms of in-stent late loss in a variety of higher risk populations for restenosis compared to the paclitaxel-eluting stent. These analyses were consistent with the in-stent late loss results of the overall SPIRIT II trial population.

  8. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    PubMed

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Predictors of early stent occlusion among plastic biliary stents.

    PubMed

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  10. Early double J stent removal in renal transplant patients to prevent urinary tract infection - systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Yahav, Dafna; Green, Hefziba; Eliakim-Raz, Noa; Mor, Eytan; Husain, Shahid

    2018-04-01

    Ureteral stents are routinely used in renal transplant and are associated with reduced urological complications but increased urinary tract infections (UTIs). There is no agreement on the preferred time to removal of stents after transplantation. We performed a systematic review and meta-analysis of all randomized controlled trials (RCTs) comparing stent duration of <14 days vs > =14 days. Electronic databases were searched to identify RCTs that compared early vs late stent removal. Primary outcome was urinary tract infections. Secondary outcomes included various urological complications. No significant difference in UTI rates was demonstrated between short and long stent duration (relative risk (RR) 0.85, 95% confidence interval (CI) 0.44-1.64), with significant heterogeneity (I 2  = 86%). Sensitivity analysis evaluating studies with low risk of bias for allocation concealment demonstrated statistically significant lower rates of UTI with short stent duration (RR 0.48, 95% CI 0.32-0.71) with no heterogeneity. No significant difference was demonstrated for the outcome of major urological complications (RR 0.72, 95% CI 0.50-1.05), without heterogeneity. Ureteral stenosis rates were significantly lower in the short duration arm (RR 0.42, 95% CI 0.18-0.98). Early removal of ureteral stents after renal transplant may be associated with reduced rates of UTI and ureteral stenosis. Additional RCTs are needed.

  11. Biodegradable nasal stents (MgF2 -coated Mg-2 wt %Nd alloy)-A long-term in vivo study.

    PubMed

    Durisin, Martin; Reifenrath, Janin; Weber, Constantin M; Eifler, Rainer; Maier, Hans J; Lenarz, Thomas; Seitz, Jan-Marten

    2017-02-01

    Despite innovative surgical techniques and use of current frontal sinus stents from different materials, the problem of treatment failure with consecutive reoperation remains present. The aim of our study is to investigate biocompatibility, degradation kinetics, and functionality of a newly developed fluoride-coated magnesium-based nasal stent. A minipig anatomy of frontal sinus adapted design and an external surgical approach were developed and established. The functionality of the stents was evaluated endoscopically. The stent-tissue blocks were analysed after 90 and 180 days using microcomputed tomography (µ-CT), histology, scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). Functional evaluation revealed an unobstructed stent lumen in all cases. Histological analysis showed moderate mucosal hyperplasia with a mild, nonspecific inflammatory response, and nonosteoconductive effect. Rejection reactions or necrosis did not occur. The volumetric analysis of the stents showed 51% volume loss after 180 days. The EDS analysis did not detect any neodymium (Nd) in the mucosa or bone. The Mg-2 wt % Nd stents are a promising option when treating the narrow passages following paranasal sinus surgery. In particular, its good biocompatibility and good functionality facilitate the re-epithelization of these constricted passages. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 350-365, 2017. © 2015 Wiley Periodicals, Inc.

  12. Outcomes of Patients Treated with the Everolimus- versus the Paclitaxel-Eluting Stents in a Consecutive Cohort of Patients at a Tertiary Medical Center.

    PubMed

    Shammas, Nicolas W; Shammas, Gail A; Nader, Elie; Jerin, Michael; Mrad, Luay; Ehrecke, Nicholas; Shammas, Waheeb J; Voelliger, Cara M; Hafez, Alexander; Kelly, Ryan; Reynolds, Emily

    2013-09-01

    In this study, we compare the outcomes of the paclitaxel-eluting stent (PES) versus the everolimus-eluting stent (EES) treated patients at a tertiary medical center and up to 2 years follow-up. Unselected consecutive patients were retrospectively recruited following stenting with PES (159 patients) or EES (189 patients). The primary endpoint of the study was target lesion failure (TLF), defined as the combined endpoint of cardiac death, nonfatal myocardial infarction (MI), or target lesion revascularization (TLR). Secondary endpoints included target vessel revascularization (TVR), TLR, target vessel failure (TVF), acute stent thrombosis (ST), total death, cardiac death, and nonfatal MI. Patients treated with the PES stent had less congestive heart failure and restenotic lesions, but a higher prevalence of longer lesions, nonleft main bifurcations, required more stents per patient (4.3 ± 2.8 vs. 2.9 ± 2.1). TLF occurred in 32.3% PES versus 21.5% EES (p = 0.027). The secondary unadjusted endpoints for PES versus EES, respectively, were TVF 38.6 versus 30.7% (p = 0.140), TVR 35.7 versus 26.5% (p = 0.079), definite and probable ST 1.2 versus 0.0%, nonfatal MI 4.5 versus 4.2%, and mortality 9.6 versus 4.0%. Logistic regression analysis showed that the numbers of stents per patient (p = 0.001), age (p = 0.01), and renal failure (p = 0.045) were independent predictors of TLF. Using univariate analysis, EES had lower TLF than PES in a cohort of unselected patients undergoing percutaneous coronary intervention at 2 years follow-up. Multivariate analysis showed that the numbers of stents per patient, age, and renal failure, but not stent type, were predictors of TLF.

  13. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    PubMed

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  14. Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy

    NASA Astrophysics Data System (ADS)

    Wang, Han-Wei; Simianu, Vlad; Locker, Mattew J.; Cheng, Ji-Xin; Sturek, Michael

    2011-02-01

    We demonstrate for the first time the applicability of multimodal nonlinear optical (NLO) microscopy to the interrogation of stented coronary arteries under different diet and stent deployment conditions. Bare metal stents and Taxus drug-eluting stents (DES) were placed in coronary arteries of Ossabaw pigs of control and atherogenic diet groups. Multimodal NLO imaging was performed to inspect changes in arterial structures and compositions after stenting. Sum frequency generation, one of the multimodalities, was used for the quantitative analysis of collagen content in the peristent and in-stent artery segments of both pig groups. Atherogenic diet increased lipid and collagen in peristent segments. In-stent segments showed decreased collagen expression in neointima compared to media. Deployment of DES in atheromatous arteries inhibited collagen expression in the arterial media.

  15. Radiotherapy Dose Perturbation of Esophageal Stents Examined in an Experimental Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atwood, Todd F.; Hsu, Annie; Ogara, Maydeen M.

    2012-04-01

    Purpose: To investigate the radiotherapy dose perturbations caused by esophageal stents in patients undergoing external beam treatments for esophageal cancer. Methods and Materials: Four esophageal stents were examined (three metallic stents: WallFlex, Ultraflex, and Alveolus; one nonmetallic stent with limited radiopaque markers for visualization: Polyflex). All experiments were performed in a liquid water phantom with a custom acrylic stent holder. Radiochromic film was used to measure the dose distributions adjacent to the stents at locations proximal and distal to the radiation source. The stents were placed in an air-filled cavity to simulate the esophagus. Treatment plans were created and deliveredmore » for photon energies of 6 and 15 MV, and data analysis was performed on uniform regions of interest, according to the size and geometric placement of the films, to quantify the dose perturbations. Results: The three metallic stents produced the largest dose perturbations with distinct patterns of 'hot' spots (increased dose) measured proximal to the radiation source (up to 15.4%) and both 'cold' (decreased dose) and hot spots measured distal to the radiation source (range, -6.1%-5.8%). The polymeric Polyflex stent produced similar dose perturbations when the radiopaque markers were examined (range, -7.6%-15.4%). However, when the radiopaque markers were excluded from the analysis, the Polyflex stent produced significantly smaller dose perturbations, with maximum hot spots of 7.3% and cold spots of -3.2%. Conclusions: The dose perturbations caused by esophageal stents during the treatment of esophageal cancer using external beam radiotherapy should be understood. These perturbations will result in hot and cold spots in the esophageal mucosa, with varying magnitudes depending on the stent. The nonmetallic Polyflex stent appears to be the most suitable for patients undergoing radiotherapy, but further studies are necessary to determine the clinical significance of the dose perturbations.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun Zhonghua, E-mail: z.sun@curtin.edu.a; Chaichana, Thanapong

    The purpose of the study was to investigate the hemodynamic effect of stent struts (wires) on renal arteries in patients with abdominal aortic aneurysms (AAAs) treated with suprarenal stent-grafts. Two sample patients with AAA undergoing multislice CT angiography pre- and postsuprarenal fixation of stent-grafts were selected for inclusion in the study. Eight juxtarenal models focusing on the renal arteries were generated from the multislice CT datasets. Four types of configurations of stent wires crossing the renal artery ostium were simulated in the segmented aorta models: a single wire crossing centrally, a single wire crossing peripherally, a V-shaped wire crossing centrally,more » and multiple wires crossing peripherally. The blood flow pattern, flow velocity, wall pressure, and wall shear stress at the renal arteries pre- and post-stent-grafting were analyzed and compared using a two-way fluid structure interaction analysis. The stent wire thickness was simulated with a diameter of 0.4, 1.0, and 2.0 mm, and hemodynamic analysis was performed at different cardiac cycles. The interference of stent wires with renal blood flow was mainly determined by the thickness of stent wires and the type of configuration of stent wires crossing the renal ostium. The flow velocity was reduced by 20-30% in most of the situations when the stent wire thickness increased to 1.0 and 2.0 mm. Of the four types of configuration, the single wire crossing centrally resulted in the highest reduction of flow velocity, ranging from 21% to 28.9% among three different wire thicknesses. Wall shear stress was also dependent on the wire thickness, which decreased significantly when the wire thickness reached 1.0 and 2.0 mm. In conclusion, our preliminary study showed that the hemodynamic effect of suprarenal stent wires in patients with AAA treated with suprarenal stent-grafts was determined by the thickness of suprarenal stent wires. Research findings in our study are useful for follow-up of patients treated with suprarenal stent-grafts to ensure long-term safety of the suprarenal fixation.« less

  17. Radiotherapy dose perturbation of esophageal stents examined in an experimental model.

    PubMed

    Atwood, Todd F; Hsu, Annie; Ogara, Maydeen M; Luba, Daniel G; Tamler, Bradley J; Disario, James A; Maxim, Peter G

    2012-04-01

    To investigate the radiotherapy dose perturbations caused by esophageal stents in patients undergoing external beam treatments for esophageal cancer. Four esophageal stents were examined (three metallic stents: WallFlex, Ultraflex, and Alveolus; one nonmetallic stent with limited radiopaque markers for visualization: Polyflex). All experiments were performed in a liquid water phantom with a custom acrylic stent holder. Radiochromic film was used to measure the dose distributions adjacent to the stents at locations proximal and distal to the radiation source. The stents were placed in an air-filled cavity to simulate the esophagus. Treatment plans were created and delivered for photon energies of 6 and 15 MV, and data analysis was performed on uniform regions of interest, according to the size and geometric placement of the films, to quantify the dose perturbations. The three metallic stents produced the largest dose perturbations with distinct patterns of "hot" spots (increased dose) measured proximal to the radiation source (up to 15.4%) and both "cold" (decreased dose) and hot spots measured distal to the radiation source (range, -6.1%-5.8%). The polymeric Polyflex stent produced similar dose perturbations when the radiopaque markers were examined (range, -7.6%-15.4%). However, when the radiopaque markers were excluded from the analysis, the Polyflex stent produced significantly smaller dose perturbations, with maximum hot spots of 7.3% and cold spots of -3.2%. The dose perturbations caused by esophageal stents during the treatment of esophageal cancer using external beam radiotherapy should be understood. These perturbations will result in hot and cold spots in the esophageal mucosa, with varying magnitudes depending on the stent. The nonmetallic Polyflex stent appears to be the most suitable for patients undergoing radiotherapy, but further studies are necessary to determine the clinical significance of the dose perturbations. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Outcomes with the paclitaxel-eluting stent in patients with acute coronary syndromes: analysis from the TAXUS-IV trial.

    PubMed

    Moses, Jeffrey W; Mehran, Roxana; Nikolsky, Eugenia; Lasala, John M; Corey, Woodrow; Albin, Glenn; Hirsch, Cary; Leon, Martin B; Russell, Mary E; Ellis, Stephen G; Stone, Gregg W

    2005-04-19

    We sought to investigate the outcomes of paclitaxel-eluting stent implantation in patients with unstable angina or non-ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention (PCI). Whether the paclitaxel-eluting stent is safe and effective in patients with acute coronary syndromes (ACS) is unknown. In the TAXUS-IV trial, 1,314 patients with stable or unstable ischemic syndromes undergoing PCI were randomized to treatment with either the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). The results were stratified by the acuity of the presenting clinical syndrome. Acute coronary syndromes were present in 450 patients (34.2%), 237 of whom were assigned to paclitaxel-eluting stents and 213 to bare-metal stents. The baseline and procedural characteristics were well matched between the groups. Clinical outcomes at 30 days were similar with both stents. At one-year follow-up, patients with ACS assigned to the paclitaxel-eluting stent compared to the control stent had strikingly lower rates of target lesion revascularization (TLR) (3.9% vs. 16.0%, p < 0.0001) and major adverse cardiac events (11.1 vs. 21.7%, p = 0.002). By multivariate analysis, ACS was an independent predictor of in-stent restenosis in the cohort treated with bare-metal stents (hazard ratio [HR] = 2.03 [95% confidence interval (CI) 1.05 to 3.92], p = 0.035), while among patients randomized to the paclitaxel-eluting stents, ACS was an independent predictor of freedom from restenosis (HR = 0.27 [95% CI 0.08 to 0.97], p = 0.04). The use of the paclitaxel-eluting TAXUS stent was safe in patients with unstable ischemic syndromes, and was associated with marked reduction of ischemia-driven TLR and adverse cardiac events at one year.

  19. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    PubMed

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  20. Impact of lesion morphology and associated procedures for left main coronary stenting on angiographic outcome after intervention: sub-analysis of Heart Research Group of Kanazawa, HERZ, Study.

    PubMed

    Kawashiri, Masa-aki; Sakata, Kenji; Uchiyama, Katsuharru; Konno, Tetsuo; Namura, Masanobu; Mizuno, Sumio; Tatami, Ryozo; Kanaya, Honin; Nitta, Yutaka; Michishita, Ichiro; Hirase, Hiroaki; Ueda, Kosei; Aoyama, Takashi; Okeie, Kazuyasu; Haraki, Tatsuo; Mori, Kiyoo; Araki, Tsutomu; Minamoto, Masaharu; Oiwake, Hisanori; Ino, Hidekazu; Hayashi, Kenshi; Yamagishi, Masakazu

    2014-04-01

    Whether the lesion morphology and associated interventional procedures for the left main coronary artery disease (LMCA) could affect clinical outcome is still controversial. Therefore, we examined the impact of lesion morphology and associated procedures on clinical and angiographic outcomes of stenting for the LMCA. Among 7,660 patients with coronary intervention registered, we analyzed early angiographic results of 228 patients (179 men, mean age 69.4 years) concerned with LMCA lesions. In 121 out of 228 patients having long-term angiographic results, we examined the occurrence of major adverse coronary events (MACE) particularly in terms of the presence of acute coronary syndrome (ACS), the kind of stents, bear metal or drug eluting, the lesion morphology and associated procedures. Early angiographic success rate of LMCA stenting was 100 %, and clinical success rate was 94.3 %. During follow-up period for 3 years, MACE was observed in 17 patients. Under these conditions, multiple stenting (p < 0.01) and complicated procedures such as such as Y-stent, T-stent and crush stent (p < 0.01) were listed as risks for MACE, although there was no statistical difference in kinds of stent. Multivariate analysis demonstrated the significant disadvantage of complicated procedures using the bear metal stent on the occurrence of MACE (p < 0.01). These results demonstrate that the complicated procedures have great impact on clinical and angiographic outcomes after stenting for LMCA lesions, and suggest the simple procedure with a single stent for LMCA lesions in the present cohort. Whether the presence of ACS can affect the prognosis should further be sought.

  1. iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis.

    PubMed

    Malvankar-Mehta, Monali S; Chen, Yufeng Nancy; Iordanous, Yiannis; Wang, Wan Wendy; Costella, John; Hutnik, Cindy M L

    2015-01-01

    Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of topical glaucoma medications occurred at 18-months after one iStent implant, 1.45 bottles per patient at 6-months after two iStents, and one bottle of medication per patient was reduced at 6-months following placement of three iStents implants. Meta-analysis results showed a significant reduction in the IOP after one iStent (SMD = -1.68, 95% CI: [-2.7, -0.61]), two iStents (SMD = -1.88, 95% CI: [-2.2, -1.56]), and three iStents (SMD = -2, 95% CI: [-2.62, -1.38]) implantation. Results showed a significant drop in the topical glaucoma medications after one iStent (SMD = -2.11, CI: [-3.95, -0.27]), two iStent (SMD = -1.88, CI: [-2.20, -1.56]), and three iStents (SMD = -2.00, CI: [-2.62, -1.38]) implantation. The maximum reduction in IOP occurred at 12-months (SMD = -2.21, CI: [-2.53, -1.88]) and a significant reduction in post-operative topical glaucoma medications occurred even after 18-months of iStent implantation (SMD = -0.71, CI: [-1.15, -0.26]). iStent implantation as a solo procedure without concurrent cataract extraction does lower IOP, and reduces the dependency on glaucoma medications. This effect seems to last at least 18 months.

  2. Direct stenting versus balloon predilation: Jury is still out.

    PubMed

    Belardi, Jorge A; Albertal, Mariano

    2017-08-01

    Compared to balloon predilation, direct stenting (DS) shortens procedural time and reduces radiation and contrast exposure. A meta-analysis that included 7 studies comparing these 2 strategies revealed lower adverse event rate with DS. Studies included in the present meta-analysis were mostly observational and utilized first generation drug-eluting stent. Patient and lesion selection may explain these positive results. © 2017 Wiley Periodicals, Inc.

  3. Computational Analysis on Stent Geometries in Carotid Artery: A Review

    NASA Astrophysics Data System (ADS)

    Paisal, Muhammad Sufyan Amir; Taib, Ishkrizat; Ismail, Al Emran

    2017-01-01

    This paper reviews the work done by previous researchers in order to gather the information for the current study which about the computational analysis on stent geometry in carotid artery. The implantation of stent in carotid artery has become popular treatment for arterial diseases of hypertension such as stenosis, thrombosis, atherosclerosis and embolization, in reducing the rate of mortality and morbidity. For the stenting of an artery, the previous researchers did many type of mathematical models in which, the physiological variables of artery is analogized to electrical variables. Thus, the computational fluid dynamics (CFD) of artery could be done, which this method is also did by previous researchers. It lead to the current study in finding the hemodynamic characteristics due to artery stenting such as wall shear stress (WSS) and wall shear stress gradient (WSSG). Another objective of this study is to evaluate the nowadays stent configuration for full optimization in reducing the arterial side effect such as restenosis rate after a few weeks of stenting. The evaluation of stent is based on the decrease of strut-strut intersection, decrease of strut width and increase of the strut-strut spacing. The existing configuration of stents are actually good enough in widening the narrowed arterial wall but the disease such as thrombosis still occurs in early and late stage after the stent implantation. Thus, the outcome of this study is the prediction for the reduction of restenosis rate and the WSS distribution is predicted to be able in classifying which stent configuration is the best.

  4. Behaviour of two typical stents towards a new stent evolution.

    PubMed

    Simão, M; Ferreira, J M; Mora-Rodriguez, J; Fragata, J; Ramos, H M

    2017-06-01

    This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interaction are used to assess the haemodynamic impact of two types of coronary stents implantation: (1) type 1-based on a strut-link stent geometry and (2) type 2-a continuous helical stent. Using data from a recent clinical stenosis, flow disturbances and consequent shear stress alterations introduced by the stent treatment are investigated. A relationship between stenosis and the induced flow fields for the two types of stent designs is analysed as well as the correlation between haemodynamics and vessel wall biomechanical factors during the initiation and development of stenosis formation in the coronary artery. Both stents exhibit a good performance in reducing the obstruction artery. However, stent type 1 presents higher radial deformation than the type 2. This deformation can be seen as a limitation with a long-term clinical impact.

  5. Internal or External Stenting of the Ureterovesical Anastomosis in Renal Transplantation.

    PubMed

    Fockens, M Matthijs; Alberts, Victor P; Bemelman, Frederike J; Laguna Pes, M Pilar; Idu, Mirza M

    2016-01-01

    Stenting of the ureterovesical anastomosis reduces the incidence of urological complications (UCs) after renal transplantation, but there are multiple stenting techniques, and there is no consensus regarding which technique is preferred. The aim of this study was to compare an internal versus an external stenting technique on the incidence of UCs. This is a retrospective analysis of 419 deceased donor renal transplantations performed between January 2008 and December 2013. Until 2011, 183 patients received an external stent through the ureterovesical anastomosis placed by suprapubic bladder puncture (SP stent). From 2011, 236 recipients received an internal double-J (JJ) stent. The rate of UC was 3.8% in JJ stents, compared to 9.3% in SP stents (p = 0.021). No difference in surgical ureter revision rate was observed between the groups (2.1 vs. 5.5%; p = 0.068). Urinary tract infection (UTI) rate and graft function were comparable between both groups. Internal JJ stenting significantly decreased the incidence of UC compared to an external SP stent. There was no difference in surgical ureter revision rate, UTI or graft function. © 2015 S. Karger AG, Basel.

  6. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries.

    PubMed

    Takimura, Celso K; Galon, Micheli Z; Gutierrez, Paulo S; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A

    2015-04-01

    Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies.

  7. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.

    PubMed

    Kogure, Hirofumi; Isayama, Hiroyuki; Nakai, Yousuke; Tsujino, Takeshi; Matsubara, Saburo; Yashima, Yoko; Ito, Yukiko; Hamada, Tsuyoshi; Takahara, Naminatsu; Miyabayashi, Koji; Mizuno, Suguru; Mohri, Dai; Kawakubo, Kazumichi; Sasaki, Takashi; Yamamoto, Natsuyo; Hirano, Kenji; Sasahira, Naoki; Tada, Minoru; Koike, Kazuhiko

    2014-01-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement in a stent-in-stent method for malignant hilar biliary obstruction is technically challenging. Technical difficulties in the initial placement and reinterventions for stent occlusion are disadvantages inherent to this stent-in-stent method. We previously reported the feasibility of Niti-S large cell D-type biliary stents (LCD). This multicenter prospective consecutive study evaluated the efficacy of bilateral SEMS placement using modified LCD with large and uniform cells, a slimmer delivery system and high radial force. From July 2010 to June 2011, 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent endoscopic bilateral placement of modified LCD in a stent-in-stent method at three tertiary hospitals. Ten patients had gallbladder cancer, eight had cholangiocarcinoma, four had lymph node metastasis, two had intrahepatic cholangiocarcinoma, and two had liver metastasis. Single-session and final technical success rate was 96% and 100%, respectively. Functional success rate was 89%. Stent occlusion occurred in 11 patients (42%) because of sludge (n = 7) or tumor ingrowth (n = 4). Endoscopic bilateral reintervention was technically easy and successful: six patients had stent clearance by balloon sweeping and five had plastic stent placement. According to Kaplan-Meier analysis, median survival and stent patency were 220 days and 157 days, respectively. Modified LCD achieved a high technical success rate both in the initial stent-in-stent placement and in bilateral reinterventions in patients with malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  8. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemes, Balazs, E-mail: nembal@freemail.hu; Lukacs, Levente; Balazs, Gyoergy

    2009-05-15

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic andmore » computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.« less

  9. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    PubMed Central

    2012-01-01

    Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS) and plastic stents (PS).We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS), functional success (FS), early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III). Results The initial stent insertion was successful in 450 (93.8%) patients. TS was achieved in 204 (88.3%) patients treated with PS and in 246 (98.8%) patients palliated with SEMS (p < 0.001). In the intention-to-treat (ITT) analysis, the FS in patients treated with SEMS (97.9%) was significantly higher than in patients treated with PS (84.8%) (p < 0.001). Late complications occurred in 115 (56.4%) patients treated with PS and 60 (24.4%) patients treated with SEMS (p < 0.001). The median duration of stent patency in weeks (w) were as follows: 20 w in patients palliated with PS and 27 w in patients treated with SEMS (p < 0.0001). In Group 2, the median duration of PS patency was 17 w and 18 w for unilateral and bilateral placement, respectively (p = 0.0004); the median duration of SEMS patency was 24 w and 29 w for unilateral and bilateral placement, respectively (p < 0.0001). Multivariate analysis using the Poisson regression showed that SEMS placement (B = 0.48; P < 0.01) and bilateral deployment (B = 0.24; P < 0.01) were the only independent prognostic factors associated with stent patency. Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients. PMID:22873816

  10. Cost-effectiveness of percutaneous coronary intervention with cobalt-chromium everolimus eluting stents versus bare metal stents: Results from a patient level meta-analysis of randomized trials.

    PubMed

    Ferko, Nicole; Ferrante, Giuseppe; Hasegawa, James T; Schikorr, Tanya; Soleas, Ireena M; Hernandez, John B; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Valgimigli, Marco

    2017-05-01

    Second-generation drug eluting stents (DES) may reduce costs and improve clinical outcomes compared to first-generation DES with improved cost-effectiveness when compared to bare metal stents (BMS). We aimed to conduct an economic evaluation of a cobalt-chromium everolimus eluting stent (Co-Cr EES) compared with BMS in percutaneous coronary intervention (PCI). To conduct a cost-effectiveness analysis (CEA) of a cobalt-chromium everolimus eluting stent (Co-Cr EES) versus BMS in PCI. A Markov state transition model with a 2-year time horizon was applied from a US Medicare setting with patients undergoing PCI with Co-Cr EES or BMS. Baseline characteristics, treatment effects, and safety measures were taken from a patient level meta-analysis of 5 RCTs (n = 4,896). The base-case analysis evaluated stent-related outcomes; a secondary analysis considered the broader set of outcomes reported in the meta-analysis. The base-case and secondary analyses reported an additional 0.018 and 0.013 quality-adjusted life years (QALYs) and cost savings of $236 and $288, respectively with Co-Cr EES versus BMS. Results were robust to sensitivity analyses and were most sensitive to the price of clopidogrel. In the probabilistic sensitivity analysis, Co-Cr EES was associated with a greater than 99% chance of being cost saving or cost effective (at a cost per QALY threshold of $50,000) versus BMS. Using data from a recent patient level meta-analysis and contemporary cost data, this analysis found that PCI with Co-Cr EES is more effective and less costly than PCI with BMS. © 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc. © 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  11. Biological effect of microengineered grooved stents on strut healing: a randomised OCT-based comparative study in humans

    PubMed Central

    Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F

    2017-01-01

    Objective To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. Background In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). Methods A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. Results At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75–95.52) compared with the MSG group (74.21%, 58.85–86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. Conclusions MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. Classifications BMS, OCT, clinical trials. PMID:28674616

  12. Biological effect of microengineered grooved stents on strut healing: a randomised OCT-based comparative study in humans.

    PubMed

    Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F

    2017-01-01

    To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75-95.52) compared with the MSG group (74.21%, 58.85-86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. BMS, OCT, clinical trials.

  13. When is carotid angioplasty and stenting the cost-effective alternative for revascularization of symptomatic carotid stenosis? A Canadian health system perspective.

    PubMed

    Almekhlafi, M A; Hill, M D; Wiebe, S; Goyal, M; Yavin, D; Wong, J H; Clement, F M

    2014-02-01

    Carotid revascularization procedures can be complicated by stroke. Additional disability adds to the already high costs of the procedure. To weigh the cost and benefit, we estimated the cost-utility of carotid angioplasty and stenting compared with carotid endarterectomy among patients with symptomatic carotid stenosis, with special emphasis on scenario analyses that would yield carotid angioplasty and stenting as the cost-effective alternative relative to carotid endarterectomy. A cost-utility analysis from the perspective of the health system payer was performed by using a Markov analytic model. Clinical estimates were based on a meta-analysis. The procedural costs were derived from a microcosting data base. The costs for hospitalization and rehabilitation of patients with stroke were based on a Canadian multicenter study. Utilities were based on a randomized controlled trial. In the base case analysis, carotid angioplasty and stenting were more expensive (incremental cost of $6107) and had a lower utility (-0.12 quality-adjusted life years) than carotid endarterectomy. The results are sensitive to changes in the risk of clinical events and the relative risk of death and stroke. Carotid angioplasty and stenting were more economically attractive among high-risk surgical patients. For carotid angioplasty and stenting to become the preferred option, their costs would need to fall from more than $7300 to $4350 or less and the risks of the periprocedural and annual minor strokes would have to be equivalent to that of carotid endarterectomy. In the base case analysis, carotid angioplasty and stenting were associated with higher costs and lower utility compared with carotid endarterectomy for patients with symptomatic carotid stenosis. Carotid angioplasty and stenting were cost-effective for patients with high surgical risk.

  14. Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

    PubMed

    Kang, Si-Hyuck; Park, Kyung Woo; Kang, Do-Yoon; Lim, Woo-Hyun; Park, Kyung Taek; Han, Jung-Kyu; Kang, Hyun-Jae; Koo, Bon-Kwon; Oh, Byung-Hee; Park, Young-Bae; Kandzari, David E; Cohen, David J; Hwang, Seung-Sik; Kim, Hyo-Soo

    2014-05-01

    The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. Study stents included BMS, paclitaxel-eluting (PES), sirolimus-eluting (SES), endeavor zotarolimus-eluting (ZES-E), cobalt-chromium everolimus-eluting (CoCr-EES), platinium-chromium everolimus-eluting (PtCr-EES), resolute zotarolimus-eluting (ZES-R), and BP biolimus-eluting stents (BP-BES). After a systematic electronic search, 113 trials with 90 584 patients were selected. The principal endpoint was definite or probable stent thrombosis (ST) defined according to the Academic Research Consortium within 1 year. Biodegradable polymer-biolimus-eluting stents [OR, 0.56; 95% credible interval (CrI), 0.33-0.90], SES (OR, 0.53; 95% CrI, 0.38-0.73), CoCr-EES (OR, 0.34; 95% CrI, 0.23-0.52), and PtCr-EES (OR, 0.31; 95% CrI, 0.10-0.90) were all superior to BMS in terms of definite or probable ST within 1 year. Cobalt-chromium everolimus-eluting stents demonstrated the lowest risk of ST of all stents at all times after stent implantation. Biodegradable polymer-biolimus-eluting stents was associated with a higher risk of definite or probable ST than CoCr-EES (OR, 1.72; 95% CrI, 1.04-2.98). All DES reduced the need for repeat revascularization, and all but PES reduced the risk of myocardial infarction compared with BMS. All DESs but PES and ZES-E were superior to BMS in terms of ST within 1 year. Cobalt-chromium everolimus-eluting stents was safer than any DES even including BP-BES. Our results suggest that not only the biodegradability of polymer, but the optimal combination of stent alloy, design, strut thickness, polymer, and drug all combined determine the safety of DES.

  15. [Stent-assisted recanalization of femoropopliteal arterial occlusive disease. Influence of stent design on patency rates].

    PubMed

    Treitl, M; Reiser, M F; Treitl, K M

    2016-03-01

    Despite enormous technical progress the results of endovascular treatment of the femoropopliteal vasculature are unsatisfactory and its role is still controversially discussed. In the past decade numerous new stent designs have come onto the market but it is unclear whether they have benefits with respect to patency rates. Comparison of published data on patency rates and target lesion revascularization rates after use of different stent designs in the femoropopliteal vasculature. Analysis of 25 published studies and registries from 2006 to 2015 for classical open-cell stents, interwoven stents and partially or fully covered stents. The published data are heterogeneous and comparative studies for different stent designs are completely missing. Over the past decade the patency rates after femoropopliteal stenting could be improved. According to available data stenting of short lesions < 5 cm does not show any benefit compared to isolated balloon angioplasty. Primary stenting is now recommended for intermediate and longer lesions > 6.4 cm. Due to the heterogeneity of published data a clear benefit for a specific stent design is not obvious; however, data for interwoven stents are promising and show a tendency towards improved patency, at least for certain lesions. Randomized controlled comparative trials are needed to confirm this result.

  16. A cost analysis of stenting in uncomplicated semirigid ureteroscopic stone removal.

    PubMed

    Seklehner, Stephan; Sievert, Karl-Dietrich; Lee, Richard; Engelhardt, Paul F; Riedl, Claus; Kunit, Thomas

    2017-05-01

    To evaluate the outcome and the costs of stenting in uncomplicated semirigid ureteroscopic stone removal. A decision tree model was created to evaluate the economic impact of routine stenting versus non-stenting strategies in uncomplicated ureteroscopy (URS). Probabilities of complications were extracted from twelve randomized controlled trials. Stone removal costs, costs for complication management, and total costs were calculated using Treeage Pro (TreeAge Pro Healthcare version 2015, Software, Inc, Williamstown Massachusetts, USA). Stone removal costs were higher in stented URS (€1512.25 vs. €1681.21, respectively). Complication management costs were higher in non-stented procedures. Both for complications treated conservatively (€189.43 vs. €109.67) and surgically (€49.26 vs. €24.83). When stone removal costs, costs for stent removal, and costs for complication management were considered, uncomplicated URS with stent placement yielded an overall cost per patient of €1889.15 compared to €1750.94 without stent placement. The incremental costs of stented URS were €138.25 per procedure. Semirigid URS with stent placement leads to higher direct procedural costs. Costs for managing URS-related complications are higher in non-stented procedures. Overall, a standard strategy of deferring routine stenting uncomplicated ureteroscopic stone removal is more cost efficient.

  17. Management of occluded self-expanding biliary metal stents in malignant biliary disease.

    PubMed

    Nennstiel, Simon; Tschurtschenthaler, Isolde; Neu, Bruno; Algül, Hana; Bajbouj, Monther; Schmid, Roland M; von Delius, Stefan; Weber, Andreas

    2018-02-01

    Occlusion of self-expanding metal stents (SEMS) in malignant biliary obstruction occurs in up to 40% of patients. This study aimed to compare the different techniques to resolve stent occlusion in our collective of patients. Patients with malignant biliary obstruction and occlusion of biliary metal stent at a tertiary referral endoscopic center were retrospectively identified between April 1, 1994 and May 31, 2014. The clinical records were further analyzed regarding the characteristics of patients, malignant strictures, SEMS, management strategies, stent patency, subsequent interventions, survival time and case charges. A total of 108 patients with biliary metal stent occlusion were identified. Seventy-nine of these patients were eligible for further analysis. Favored management was plastic stent insertion in 73.4% patients. Second SEMS were inserted in 12.7% patients. Percutaneous transhepatic biliary drainage and mechanical cleansing were conducted in a minority of patients. Further analysis showed no statistically significant difference in median overall secondary stent patency (88 vs. 143 days, P = 0.069), median survival time (95 vs. 192 days, P = 0.116), median subsequent intervention rate (53.4% vs. 40.0%, P = 0.501) and median case charge (€5145 vs. €3473, P = 0.803) for the treatment with a second metal stent insertion compared to plastic stent insertion. In patients with survival time of more than three months, significantly more patients treated with plastic stents needed re-interventions than patients treated with second SEMS (93.3% vs. 57.1%, P = 0.037). In malignant biliary strictures, both plastic and metal stent insertions are feasible strategies for the treatment of occluded SEMS. Our data suggest that in palliative biliary stenting, patients especially those with longer expected survival might benefit from second SEMS insertion. Careful patient selection is important to ensure a proper decision for either management strategy. Copyright © 2018 First Affiliated Hospital, Zhejiang University School of Medicine in China. Published by Elsevier B.V. All rights reserved.

  18. The effect of vessel material properties and pulsatile wall motion on the fixation of a proximal stent of an endovascular graft.

    PubMed

    Corbett, T J; Molony, D S; Callanan, A; McGloughlin, T M

    2011-01-01

    Migration is a serious failure mechanism associated with endovascular abdominal aortic aneurysm (AAA) repair (EVAR). The effect of vessel material properties and pulsatile wall motion on stent fixation has not been previously investigated. A proximal stent from a commercially available stent graft was implanted into the proximal neck of silicone rubber abdominal aortic aneurysm models of varying proximal neck stiffness (β=25.39 and 20.44). The stent was then dislodged by placing distal force on the stent struts. The peak force to completely dislodge the stent was measured using a loadcell. Dislodgment was performed at ambient pressure with no flow (NF) and during pulsatile flow (PF) at pressures of 120/80 mmHg and 140/100 mmHg to determine if pulsatile wall motions affected the dislodgement force. An imaging analysis was performed at ambient pressure and at pressures of 120 mmHg and 140 mmHg to investigate diameter changes on the model due to the radial force of the stent and internal pressurisation. Stent displacement forces were ~50% higher in the stiffer model (7.16-8.4 N) than in the more compliant model (3.67-4.21 N). The mean displacement force was significantly reduced by 10.95-12.83% from the case of NF to the case of PF at 120/80 mmHg. A further increase in pressure to 140/120 mmHg had no significant effect on the displacement force. The imaging analysis showed that the diameter in the region of the stent was 0.37 mm greater in the less stiff model at all the pressures which could reduce the fixation of the stent. The results suggest that the fixation of passively fixated aortic stents could be comprised in more compliant walls and that pulsatile motions of the wall can reduce the maximum stent fixation. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    PubMed

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    PubMed

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  1. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study

    PubMed Central

    Ionita, Ciprian N.; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M.; Hoffmann, K R.; Bednarek, D. R.; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage. PMID:19763252

  2. Development of asymmetric stent for treatment of eccentric plaque.

    PubMed

    Syaifudin, Achmad; Takeda, Ryo; Sasaki, Katsuhiko

    2018-01-01

    The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat eccentric plaque using structural transient dynamic analysis in ANSYS. A non-symmetric structural geometry of stent is generated to obtain reasonable stress distribution safe for the arterial layer surrounding the stent. To derive the novel structural geometry, a Sinusoidal stent type is modified by varying struts length and width, adding bridges, and varying curvature width of struts. An end ring of stent struts was also modified to eliminate dogboning phenomenon and to reduce the Ectropion angle. Two balloon types were used to deploy the stent, an ordinary cylindrical and offset balloon. Positive modification results were used to construct the final non-symmetric stent design, called an Asymmetric stent. Analyses of the deformation characteristics, changes in surface roughness and induced stresses within intact arterial layer were subsequently examined. Interaction between the stent and vessel wall was implemented by means of changes in surface roughness and stress distribution analyses. The Palmaz and the Sinusoidal stent were used for a comparative study. This study indicated that the Asymmetric stent types reduced the central radial recoiling and the dogboning phenomenon. In terms of changes in surface roughness and induced stresses, the Asymmetric stent has a comparable effect with that of the Sinusoidal stent. In addition, it could enhance the distribution of surface roughening as expanded by an offset balloon.

  3. Computational Study of Axial Fatigue for Peripheral Nitinol Stents

    NASA Astrophysics Data System (ADS)

    Meoli, Alessio; Dordoni, Elena; Petrini, Lorenza; Migliavacca, Francesco; Dubini, Gabriele; Pennati, Giancarlo

    2014-07-01

    Despite their success as primary treatment for vascular diseases, Nitinol peripheral stents are still affected by complications related to fatigue failure. Hip and knee movements during daily activities produce large and cyclic deformations of the superficial femoral artery, that concomitant to the effects of pulsatile blood pressure, may cause fatigue failure in the stent. Fatigue failure typically occurs in cases of very extended lesions, which often require the use of two or more overlapping stents. In this study, finite element models were used to study the fatigue behavior of Nitinol stents when subjected to cyclic axial compression in different conditions. A specific commercial Nitinol stent was chosen for the analysis and subjected to cyclic axial compression typical of the femoral vascular region. Three different configurations were investigated: stent alone, stent deployed in a tube, and two overlapping stents deployed in a tube. Results confirm that stent oversizing has an influence in determining both the mean and amplitude strains induced in the stent and plays an important role in determining the fatigue response of Nitinol stents. In case of overlapping stents, numerical results suggest higher amplitude strains concentrate in the region close to the overlapping portion where the abrupt change in stiffness causes higher cyclic compression. These findings help to explain the high incidence of stent fractures observed in various clinical trials located close to the overlapping portion.

  4. The Need For Dedicated Bifurcation Stents: A Critical Analysis

    PubMed Central

    Lesiak, Maciej

    2016-01-01

    There is growing evidence that optimally performed two-stent techniques may provide similar or better results compared with the simple techniques for bifurcation lesions, with an observed trend towards improvements in clinical and/or angiographic outcomes with a two-stent strategy. Yet, provisional stenting remains the treatment of choice. Here, the author discusses the evidence – and controversies – concerning when and how to use complex techniques. PMID:29588719

  5. In vitro simulator with numerical stress analysis for evaluation of stent-assisted coiling embolization in cerebral aneurysm treatments.

    PubMed

    Shi, Chaoyang; Kojima, Masahiro; Tercero, Carlos; Najdovski, Zoran; Ikeda, Seiichi; Fukuda, Toshio; Arai, Fumihito; Negoro, Makoto

    2014-12-01

    There are several complications associated with Stent-assisted Coil Embolization (SACE) in cerebral aneurysm treatments, due to damaging operations by surgeons and undesirable mechanical properties of stents. Therefore, it is necessary to develop an in vitro simulator that provides both training and research for evaluating the mechanical properties of stents. A new in vitro simulator for three-dimensional digital subtraction angiography was constructed, followed by aneurysm models fabricated with new materials. Next, this platform was used to provide training and to conduct photoelastic stress analysis to evaluate the SACE technique. The average interaction stress increasingly varied for the two different stents. Improvements for the Maximum-Likelihood Expectation-Maximization method were developed to reconstruct cross-sections with both thickness and stress information. The technique presented can improve a surgeon's skills and quantify the performance of stents to improve mechanical design and classification. This method can contribute to three-dimensional stress and volume variation evaluation and assess a surgeon's skills. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Intensive oral antiplatelet therapy for reduction of ischaemic events including stent thrombosis in patients with acute coronary syndromes treated with percutaneous coronary intervention and stenting in the TRITON-TIMI 38 trial: a subanalysis of a randomised trial.

    PubMed

    Wiviott, Stephen D; Braunwald, Eugene; McCabe, Carolyn H; Horvath, Ivan; Keltai, Matyas; Herrman, Jean-Paul R; Van de Werf, Frans; Downey, William E; Scirica, Benjamin M; Murphy, Sabina A; Antman, Elliott M

    2008-04-19

    Intracoronary stenting can improve procedural success and reduce restenosis compared with balloon angioplasty in patients with acute coronary syndromes, but can also increase the rate of thrombotic complications including stent thrombosis. The TRITON-TIMI 38 trial has shown that prasugrel-a novel, potent thienopyridine-can reduce ischaemic events compared with standard clopidogrel therapy. We assessed the rate, outcomes, and prevention of ischaemic events in patients treated with prasugrel or clopidogrel with stents in the TRITON-TIMI 38 study. Patients with moderate-risk to high-risk acute coronary syndromes were included in our analysis if they had received at least one coronary stent at the time of the index procedure following randomisation in TRITON-TIMI 38, and were further subdivided by type of stent received. Patients were randomly assigned in a 1 to 1 fashion to receive a loading dose of study drug (prasugrel 60 mg or clopidogrel 300 mg) as soon as possible after randomisation, followed by daily maintenance therapy (prasugrel 10 mg or clopidogrel 75 mg). All patients were to receive aspirin therapy. Treatment was to be continued for a minimum of 6 months and a maximum of 15 months. Randomisation was not stratified by stents used or stent type. The primary endpoint was the composite of cardiovascular death, non-fatal myocardial infarction, or non-fatal stroke. Stent thrombosis was assessed using Academic Research Consortium definitions, and analysis was by intention to treat. TRITON-TIMI 38 is registered with ClinicalTrials.gov, number NCT00097591. 12,844 patients received at least one coronary stent; 5743 received only drug-eluting stents, and 6461 received only bare-metal stents. Prasugrel compared with clopidogrel reduced the primary endpoint (9.7 vs 11.9%, HR 0.81, p=0.0001) in the stented cohort, in patients with only drug-eluting stents (9.0 vs 11.1%, HR 0.82, p=0.019), and in patients with only bare-metal stents (10.0 vs 12.2%, HR 0.80, p=0.003). Stent thrombosis was associated with death or myocardial infarction in 89% (186/210) of patients. Stent thrombosis was reduced with prasugrel overall (1.13 vs 2.35%, HR 0.48, p<0.0001), in patients with drug-eluting stents only (0.84 vs 2.31%, HR 0.36, p<0.0001), and in those with bare-metal stents only (1.27 vs 2.41%, HR 0.52, p=0.0009). Intensive antiplatelet therapy with prasugrel resulted in fewer ischaemic outcomes including stent thrombosis than with standard clopidogrel. These findings were statistically robust irrespective of stent type, and the data affirm the importance of intensive platelet inhibition in patients with intracoronary stents.

  7. Evaluation on Compressive Characteristics of Medical Stents Applied by Mesh Structures

    NASA Astrophysics Data System (ADS)

    Hirayama, Kazuki; He, Jianmei

    2017-11-01

    There are concerns about strength reduction and fatigue fracture due to stress concentration in currently used medical stents. To address these problems, meshed stents applied by mesh structures were interested for achieving long life and high strength perfromance of medical stents. The purpose of this study is to design basic mesh shapes to obatin three dimensional (3D) meshed stent models for mechanical property evaluation. The influence of introduced design variables on compressive characteristics of meshed stent models are evaluated through finite element analysis using ANSYS Workbench code. From the analytical results, the compressive stiffness are changed periodically with compressive directions, average results need to be introduced as the mean value of compressive stiffness of meshed stents. Secondly, compressive flexibility of meshed stents can be improved by increasing the angle proportional to the arm length of the mesh basic shape. By increasing the number of basic mesh shapes arranged in stent’s circumferential direction, compressive rigidity of meshed stent tends to be increased. Finaly reducing the mesh line width is found effective to improve compressive flexibility of meshed stents.

  8. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries

    PubMed Central

    Galon, Micheli Z.; Gutierrez, Paulo S.; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A.

    2015-01-01

    Background Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). Methods In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. Results According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. Conclusions The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies. PMID:25984451

  9. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    PubMed

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm 2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  10. Effect of mobile phone reminder messages on adherence of stent removal or exchange in patients with benign pancreaticobiliary diseases: a prospectively randomized, controlled study.

    PubMed

    Gu, Yong; Wang, Limei; Zhao, Lina; Liu, Zhiguo; Luo, Hui; Tao, Qin; Zhang, Rongchun; He, Shuixiang; Wang, Xiangping; Huang, Rui; Zhang, Linhui; Pan, Yanglin; Guo, Xuegang

    2016-08-26

    Plastic and covered metal stents need to be removed or exchanged within appropriate time in case of undesirable complications. However, it is not uncommon that patients do not follow the recommendation for further stent management after Endoscopic Retrograde Cholangiopancreatography (ERCP). The effect of short message service (SMS) intervention monthly on the stent removal/exchange adherence in patients after ERCP is unknown at this time. A prospective, randomized controlled study was conducted. After receiving regular instructions, patients were randomly assigned to receive SMS reminding monthly (SMS group) for stent removal/exchange or not (control group). The primary outcome was stent removal/exchange adherence within appropriate time (4 months for plastic stent or 7 months for covered stent). Multivariate analysis was performed to assess factors associated with stent removal/exchange adherence within appropriate time. Intention-to-treat analysis was used. A total of 48 patients were randomized, 23 to the SMS group and 25 to the control. Adherence to stent removal/exchange was reported in 78.2 % (18/23) of patients receiving the SMS intervention compared with 40 % (10/25) in the control group (RR 1.98, 95 % CI 1.16-3.31; p = 0 · 010). Among patients with plastic stent insertion, the median interval time from stent implantation to stent removal/exchange were 90 days in the SMS group and 136 days in the control respectively (HR 0.36, 95 % CI 0.16-0.84, p = 0.018). No difference was found between the two groups regarding late-stage stent-related complications. The rate of recurrent abdominal pain tended to be lower in SMS group without significant difference (8.7 vs 28 %, p = 0.144). Multivariate logistic regression analyses revealed that SMS reminding was the only factor associated with adherence of stent removal/exchange (OR 6.73, 95 % CI 1.64-27.54, p = 0.008). This first effectiveness trial demonstrated that SMS reminding monthly could significantly increase the patient adherence to stent removal/exchange after ERCP. The study was respectively registered on July 10 in 2016 at ClinicalTrials.gov ( NCT02831127 ).

  11. Peripheral Stent Thrombosis Leading to Acute Limb Ischemia and Major Amputation: Incidence and Risk Factors in the Aortoiliac and Femoropopliteal Arteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Al-Lamki, Said A. M.; Parthipun, Aneeta

    PurposeTo report the real-world incidence and risk factors of stent thrombosis in the aortoiliac and femoropopliteal arteries in case of bare nitinol stent (BNS) or covered nitinol stent (CNS) placement from a single-centre retrospective audit.Materials and MethodsMedical records of consecutive patients treated with peripheral stent placement for claudication or critical limb ischemia were audited for definite stent thrombosis defined as imaging confirmed stent thrombosis that presented as acute limb-threatening ischemia. Cases were stratified between aortoiliac and femoropopliteal anatomy. Cox regression analysis was employed to adjust for baseline clinical and procedural confounders and identify predictors of stent thrombosis and major limbmore » loss.Results256 patients (n = 277 limbs) were analysed over a 5-year period (2009–2014) including 117 aortoiliac stents (34 CNS; 12.8 ± 5.0 cm and 83 BNS; 7.8 ± 4.0 cm) and 160 femoropopliteal ones (60 CNS; 21.1 ± 11.0 cm and 100 BNS; 17.5 ± 11.9 cm). Median follow-up was 1 year. Overall stent thrombosis rate was 6.1% (17/277) after a median of 43 days (range 2–192 days) and affected almost exclusively the femoropopliteal segment (12/60 in the CNS cohort vs. 4/100 in the BNS; p = 0.001). Annualized stent thrombosis rates (per 100 person-years) were 12.5% in case of CNS and 1.4% in case of BNS (HR 6.3, 95% CI 2.4–17.9; p = 0.0002). Corresponding major amputations rates were 8.7 and 2.5%, respectively (HR 4.5, 95% CI 2.7–27.9; p = 0.0006). On multivariable analysis, critical leg ischemia and CNS placement were the only predictors of stent thrombosis. Diabetes, critical leg ischemia, femoropopliteal anatomy, long stents and CNS were independent predictors of major amputations.ConclusionsPlacement of long femoropopliteal covered nitinol stents is associated with an increased incidence of acute stent thrombosis and ensuing major amputation. Risks are significantly lower in the aortoiliac vessels and with use of bare nitinol stents.« less

  12. New-generation stents compared with coronary bypass surgery for unprotected left main disease: A word of caution.

    PubMed

    Benedetto, Umberto; Taggart, David P; Sousa-Uva, Miguel; Biondi-Zoccai, Giuseppe; Di Franco, Antonino; Ohmes, Lucas B; Rahouma, Mohamed; Kamel, Mohamed; Caputo, Massimo; Girardi, Leonard N; Angelini, Gianni D; Gaudino, Mario

    2018-05-01

    With the advent of bare metal stents and drug-eluting stents, percutaneous coronary intervention has emerged as an alternative to coronary artery bypass grafting surgery for unprotected left main disease. However, whether the evolution of stents technology has translated into better results after percutaneous coronary intervention remains unclear. We aimed to compare coronary artery bypass grafting with stents of different generations for left main disease by performing a Bayesian network meta-analysis of available randomized controlled trials. All randomized controlled trials with at least 1 arm randomized to percutaneous coronary intervention with stents or coronary artery bypass grafting for left main disease were included. Bare metal stents and drug-eluting stents of first- and second-generation were compared with coronary artery bypass grafting. Poisson methods and Bayesian framework were used to compute the head-to-head incidence rate ratio and 95% credible intervals. Primary end points were the composite of death/myocardial infarction/stroke and repeat revascularization. Nine randomized controlled trials were included in the final analysis. Six trials compared percutaneous coronary intervention with coronary artery bypass grafting (n = 4654), and 3 trials compared different types of stents (n = 1360). Follow-up ranged from 6 months to 5 years. Second-generation drug-eluting stents (incidence rate ratio, 1.3; 95% credible interval, 1.1-1.6), but not bare metal stents (incidence rate ratio, 0.63; 95% credible interval, 0.27-1.4), and first-generation drug-eluting stents (incidence rate ratio, 0.85; 95% credible interval, 0.65-1.1) were associated with a significantly increased risk of death/myocardial infarction/stroke when compared with coronary artery bypass grafting. When compared with coronary artery bypass grafting, the highest risk of repeat revascularization was observed for bare metal stents (hazard ratio, 5.1; 95% confidence interval, 2.1-14), whereas first-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) and second-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) were comparable. The introduction of new-generation drug-eluting stents did not translate into better outcomes for percutaneous coronary intervention when compared with coronary artery bypass grafting. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of symptoms and patients' comfort for JJ-ureteral stents with and without antireflux-membrane valve.

    PubMed

    Ecke, Thorsten H; Bartel, Peter; Hallmann, Steffen; Ruttloff, Jürgen

    2010-01-01

    To evaluate safety and patients' comfort by using the ureteral stent symptom questionnaire. Ureteral stents are used to provide upper urinary-tract drainage. A total of 133 JJ-ureteral stents with and without antireflux-membrane valve as consecutive referrals for therapy of hydronephrosis have been inserted. Four weeks after insertion of the ureteral stent, the patients were asked about pain while urination, flank pain due to reflux, and the comparison with former stents. Ultrasound of the kidney for hydronephrosis grade and creatinine value as follow-up have been documented. Statistical analysis included chi(2) test after Pearson correlation computed and performed by SPSS software. We found a high correlation between the JJ-ureteral stent used and the detection of a hydronephrosis (P = .004). More patients who had a JJ-ureteral stent without valve complained of flank pain (P <.0005) and pain in the bladder (P <.0005). Patients who had a ureteral stent before were asked to compare new stents with the former ones. No patients with a JJ-ureteral stent with valve found this one to be worse than what they had before. JJ-stent related symptoms are a major problem for these patients. New stent designs and materials will be developed in the future to reduce stent-related morbidity and improve patient comfort. JJ-ureteral stents with an antireflux-membrane valve have a lower complication rate and provide a higher patient comfort compared with stents without valve. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.

  14. Impact of loop-tail ureteral stents on ureteral stent-related symptoms immediately after ureteroscopic lithotripsy: Comparison with pigtail ureteral stents

    PubMed Central

    Inoue, Takaaki; Muguruma, Kouei; Murota, Takashi; Kinoshita, Hidefumi; Matsuda, Tadashi

    2017-01-01

    Purpose To evaluate urination-related quality of life (QoL) in patients with an indwelling ureteral stent immediately after ureteroscopic lithotripsy (URSL) for upper urinary calculi. We compared the effects of loop-tail and pigtail ureteral stents on urination-related QoL. Materials and Methods Of 135 patients who underwent URSL between May 2014 and March 2015 at our hospital, we retrospectively analyzed the records of 70 patients (42 men, 28 women; median age, 63 years) in whom the stent tail was positioned inside the bladder without crossing the midline and who completed the core lower urinary tract symptoms score (CLSS) questionnaire pre- and postoperatively. Results There were significant differences in incomplete emptying (p=0.048) and bladder pain (p=0.041) between patients with loop-tail versus pigtail ureteral stents after URSL. In the multivariate analysis, stent type had a stronger association with incomplete emptying (p=0.022) and bladder pain (p=0.018) than age, sex, body mass index, stent side, operation time, diameter of ureteral access sheath, and stent type. Conclusions Patients with loop-tail ureteral stents had better urination-related QoL in the immediate post-URSL stage than patients with pigtail stents. PMID:29124244

  15. Fabrication of balloon-expandable self-lock drug-eluting polycaprolactone stents using micro-injection molding and spray coating techniques.

    PubMed

    Liu, Shih-Jung; Chiang, Fu-Jun; Hsiao, Chao-Ying; Kau, Yi-Chuan; Liu, Kuo-Sheng

    2010-10-01

    The purpose of this report was to develop novel balloon-expandable self-lock drug-eluting poly(ε-caprolactone) stents. To fabricate the biodegradable stents, polycaprolactone (PCL) components were first fabricated by a lab-scale micro-injection molded machine. They were then assembled and hot-spot welded into mesh-like stents of 3 and 5 mm in diameters. A special geometry of the components was designed to self-lock the assembled stents and to resist the external pressure of the blood vessels after being expanded by balloons. Characterization of the biodegradable PCL stents was carried out. PCL stents exhibited comparable mechanical property to that of metallic stents. No significant collapse pressure reduction and weight loss of the stents were observed after being submerged in PBS for 12 weeks. In addition, the developed stent was coated with paclitaxel by a spray coating technique and the release characteristic of the drug was determined by an in vitro elution method. The high-performance liquid chromatography analysis showed that the biodegradable stents could release a high concentration of paclitaxel for more than 60 days. By adopting the novel techniques, we will be able to fabricate biodegradable drug-eluting PCL stents of different sizes for various cardiovascular applications.

  16. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.

    PubMed

    Kandzari, David E; Mauri, Laura; Koolen, Jacques J; Massaro, Joseph M; Doros, Gheorghe; Garcia-Garcia, Hector M; Bennett, Johan; Roguin, Ariel; Gharib, Elie G; Cutlip, Donald E; Waksman, Ron

    2017-10-21

    The development of coronary drug-eluting stents has included use of new metal alloys, changes in stent architecture, and use of bioresorbable polymers. Whether these advancements improve clinical safety and efficacy has not been shown in previous randomised trials. We aimed to examine the clinical outcomes of a bioresorbable polymer sirolimus-eluting stent compared with a durable polymer everolimus-eluting stent in a broad patient population undergoing percutaneous coronary intervention. BIOFLOW V was an international, randomised trial done in patients undergoing elective and urgent percutaneous coronary intervention in 90 hospitals in 13 countries (Australia, Belgium, Canada, Denmark, Germany, Hungary, Israel, the Netherlands, New Zealand, South Korea, Spain, Switzerland, and the USA). Eligible patients were those aged 18 years or older with ischaemic heart disease undergoing planned stent implantation in de-novo, native coronary lesions. Patients were randomly assigned (2:1) to either an ultrathin strut (60 μm) bioresorbable polymer sirolimus-eluting stent or to a durable polymer everolimus-eluting stent. Randomisation was via a central web-based data capture system (mixed blocks of 3 and 6), and stratified by study site. The primary endpoint was 12-month target lesion failure. The primary non-inferiority comparison combined these data from two additional randomised trials of bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent with Bayesian methods. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02389946. Between May 8, 2015, and March 31, 2016, 4772 patients were recruited into the study. 1334 patients met inclusion criteria and were randomly assigned to treatment with bioresorbable polymer sirolimus-eluting stents (n=884) or durable polymer everolimus-eluting stents (n=450). 52 (6%) of 883 patients in the bioresorbable polymer sirolimus-eluting stent group and 41 (10%) of 427 patients in the durable polymer everolimus-eluting stent group met the 12-month primary endpoint of target lesion failure (95% CI -6·84 to -0·29, p=0·0399), with differences in target vessel myocardial infarction (39 [5%] of 831 patients vs 35 [8%] of 424 patients, p=0·0155). The posterior probability that the bioresorbable polymer sirolimus-eluting stent is non-inferior to the durable polymer everolimus-eluting stent was 100% (Bayesian analysis, difference in target lesion failure frequency -2·6% [95% credible interval -5·5 to 0·1], non-inferiority margin 3·85%, n=2208). The outperformance of the ultrathin, bioresorbable polymer sirolimus-eluting stent over the durable polymer everolimus-eluting stent in a complex patient population undergoing percutaneous coronary intervention suggests a new direction in improving next generation drug-eluting stent technology. BIOTRONIK. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. True coronary bifurcation lesions: meta-analysis and review of literature.

    PubMed

    Athappan, Ganesh; Ponniah, Thirumalaikolundiusubramanian; Jeyaseelan, Lakshmanan

    2010-02-01

    Percutaneous intervention of true coronary bifurcation lesions is challenging. Based on the results of randomized trials and registry data, the approach of stenting of main vessel only with balloon dilatation of the side branch has become the default approach for false bifurcation lesions except when a complication occurs or in cases of suboptimal result. However, the optimal stenting strategy for true coronary bifurcation lesions - to stent or not to stent the side branch - is still a matter of debate. The purpose of this study was, therefore, to compare the clinical and angiographic outcomes of the double stent technique (stenting of the main branch and side branch) over the single stent technique (stenting of main vessel only with balloon dilatation of the side branch) for treatment of true coronary bifurcation lesions, with drug-eluting stents (DES). Comparative studies published between January 2000 and February 2009 of the double stent technique vs. single stent technique with DES for true coronary bifurcations were identified using an electronic search and reviewed using a random effects model. The primary endpoints of our study were side-branch and main-branch restenoses, all-cause mortality, myocardial infarction (MI) and target lesion revascularization (TLR) at longest available follow-up. The secondary endpoints of our analysis were postprocedural minimal luminal diameter (MLD) of the side branch and main branch, follow-up MLD of side branch and main branch and stent thrombosis. Heterogeneity was assessed and sensitivity analysis was performed to test the robustness of the overall summary odds ratios (ORs). Five studies comprising 1145 patients (616 single stent and 529 double stent) were included in the analysis. Three studies were randomized comparisons between the two techniques for true coronary bifurcation lesions. Incomplete reporting of data in the primary studies was common. The lengths of clinical and angiographic follow-up ranged between 6 and 12 months and 6 and 7 months, respectively. Postprocedural MLD of the side branch was significantly smaller in the single stent group [standardized mean difference (SMD) -0.71, 95% CI -0.88 to -0.54, P < 0.000, I2 = 0%]. The odds of side-branch restenosis (OR 1.11, 95% CI 0.47-2.67, P = 0.81, I2 = 76%), main-branch restenois (OR 0.88, 95% CI 0.56-1.39, P = 0.58, I = 0%), all-cause mortality (OR 0.52, 95% CI 0.11-2.45, P = 0.41, I2 = 0%), MI (OR 0.92, 95% CI 0.34-2.54, P = 0.87, I = 49%) and TLR (OR 0.87, 95% CI 0.46-1.65, P = 0.68, I2 = 0%) were similar between the two groups. Postprocedural MLD of the main branch [standardized mean difference (SMD) -0.08, 95% CI -0.42 to -0.26, P < 0.65, I2 = 67%], follow-up MLD of side branch (SMD -0.19, 95% CI -0.40 to 0.01, P < 0.31, I2 = 15%) and main branch MLD (SMD 0.17, 95% CI -0.18 to 0.542, P < 0.35, I2 = 65%) were also similar between the two groups. In patients undergoing percutaneous coronary intervention (PCI) for true coronary bifurcations, there is no added advantage of stenting both branches as compared with a conventional one-stent strategy. The results, however, need to be interpreted considering the poor study methods and/or poor quality of reporting in publications. We propose to move forward and consider the conduct of more systematic, well-designed and scientific trials to investigate the treatment of true coronary bifurcation lesions.

  18. In Situ Fracture of Stents Implanted for Relief of Pulmonary Arterial Stenosis in Patients with Congenitally Malformed Hearts

    PubMed Central

    McElhinney, Doff B.; Bergersen, Lisa; Marshall, Audrey C.

    2014-01-01

    Background One of the most common uses of stents in patients with congenitally malformed hearts is treatment of pulmonary arterial stenosis. Although there are reports of fractured pulmonary arterial stents, little is known about the risk factors for, and implications of, such fractures. Methods We reviewed angiograms to identify fractures in stents previously inserted to relieve stenoses in pulmonary arteries from 1990 through 2001 in patients who also underwent follow-up catheterization at least 3 years after placement of the stent. We undertook matched cohort analysis, matching a ratio of 2 fractured to 1 unfractured stent. Results Overall, 166 stents meeting the criterions of our study had been placed in 120 patients. We identified fractures in 35 stents (21%) in 29 patients. All fractured stents were in the central pulmonary arteries, 24 (69%) in the central part of the right pulmonary artery, and all were complete axial fractures, or complex fractures along at least 2 planes. Stent-related factors associated with increased risk of fracture identified by multivariable logistic regression included placement in close apposition to the ascending aorta (p = 0.001), and a larger expanded diameter (p = 0.002). There was obstruction across 28 of 35 fractured stents, which was severe in 11. We re-stented 21 of the fractured stents, and recurrent fracture was later diagnosed in 3 of these. A fragment of the fractured stent embolized distally in 2 patients, without clinically important effects. Conclusions In situ fracture of pulmonary arterial stents is relatively common, and in most cases is related to compression by the aorta. There is usually recurrent obstruction across the fractured stent, but fractured stents rarely embolize, and are not associated with other significant complications. PMID:18559137

  19. Comparison of intraluminal radiofrequency ablation and stents vs. stents alone in the management of malignant biliary obstruction.

    PubMed

    Cui, Wei; Wang, Yu; Fan, Wenzhe; Lu, Mingjian; Zhang, Yingqiang; Yao, Wang; Li, Jiaping

    2017-11-01

    To retrospectively evaluate the added benefit of adding intraluminal radiofrequency ablation (RFA) to biliary metal stent placement for patients with malignant biliary obstruction (MBO). From November 2013 to December 2015, 89 patients with MBO who had undergone percutaneous intraluminal RFA and stent placement (RFA-stent group, n = 50) or stent placement only (stent group, n = 39) were included. Outcomes were compared according to the type of tumour: cholangiocarcinoma or non-cholangiocarcinoma. Primary and secondary stent patency (PSP, SSP) were significantly higher for the RFA-stent group than the stent group (PSP: 7.0 months vs. 5.0 months, p = 0.006; SSP: 10.0 months vs. 5.6 months, p < 0.001), with overall survival being comparable (5.0 months vs. 4.7 months, p = 0.068). In subgroup analysis, RFA-stent showed significant PSP benefits compared to stent alone in patients with cholangiocarcinoma (7.4 months vs. 4.3 months; p = 0.009), but with comparable outcomes in patients with non-cholangiocarcinoma (6.3 months vs. 5.2 months; p = 0.266). The SSP was improved in both subgroups (cholangiocarcinoma, 12.6 months vs. 5.0 months, p < 0.001; non-cholangiocarcinoma, 10.3 months vs. 5.5 months, p = 0.013). Technical success and clinical success were not significantly different between the two groups. The rate of complication was higher for the RFA-stent group, but tolerable when compared to the stent group. Although survival was comparable between the groups, RFA-stent confers therapeutic benefits to patients with MBO in terms of stent patency compared to stent placement alone, especially in those with cholangiocarcinoma.

  20. The BioStent: novel concept for a viable stent structure.

    PubMed

    Weinandy, Stefan; Rongen, Lisanne; Schreiber, Fabian; Cornelissen, Christian; Flanagan, Thomas Cormac; Mahnken, Andreas; Gries, Thomas; Schmitz-Rode, Thomas; Jockenhoevel, Stefan

    2012-09-01

    Percutaneous stenting of occluded peripheral vessels is a well-established technique in clinical practice. Unfortunately, the patency rates of small-caliber vessels after stenting remain unsatisfactory. The aim of the BioStent concept is to overcome in-stent restenosis by excluding the diseased vessel segment entirely from the blood stream, in addition to providing an intact endothelial cell layer. The concept combines the principles of vascular tissue engineering with a self-expanding stent: casting of the stent within a cellularized fibrin gel structure, followed by bioreactor conditioning, allows complete integration of the stent within engineered tissue. Small-caliber BioStents (Ø=6 mm; n=4) were produced by casting a nitinol stent within a thin fibrin/vascular smooth muscle cell (vSMC) mixture, followed by luminal endothelial cell seeding, and conditioning of the BioStent within a bioreactor system. The potential remodeling of the fibrin component into tissue was analyzed using routine histological methods. Scanning electron microscopy was used to assess the luminal endothelial cell coverage following the conditioning phase and crimping of the stent. The BioStent was shown to be noncytotoxic, with no significant effect on cell proliferation. Gross and microscopic analysis revealed complete integration of the nitinol component within a viable tissue structure. Hematoxylin and eosin staining revealed a homogenous distribution of vSMCs throughout the thickness of the BioStent, while a smooth, confluent luminal endothelial cell lining was evident and not significantly affected by the crimping/release process. The BioStent concept is a platform technology offering a novel opportunity to generate a viable, self-expanding stent structure with a functional endothelial cell lining. This platform technology can be transferred to different applications depending on the luminal cell lining required.

  1. Experimental Evaluation of a New Tubular Coronary Stent (V-Flexª).

    PubMed

    Shun; Wang; Zhou; Verbeken; Ping; Szilard; Yanming; Jianhua; De Scheerder IK

    1998-11-01

    The safety, efficacy, angiographic and histological effects of a new 316 L, SS seamless stainless steel tubular stent (V-Flexª, Global Therapeutics, Broomfield, Colorado) was evaluated in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 16 pigs. Eight pigs were angiographically controlled after 6 weeks and then sacrificed for morphometric analysis. All stented coronary vessels were widely patent at this moment and morphometric analysis showed only a mild fibromuscular neointimal hyperplasia resulting in a neointimal hyperplasia of 1.15 +/- 0.38 mm2. The remaining 8 pigs were controlled and sacrificed at 12 weeks. At that time, all stented vessels were patent and neointimal hyperplasia was 1.22 +/- 0.34 mm2. Comparison with the Palmaz-Schatzª coronary stent (Cordis, Miami, Florida) in a porcine peripheral artery model demonstrated significantly less neointimal hyperplasia at 6 weeks (1.11 +/- 0.73 vs. 2.40 +/- 0.36, p = 0.001) and at 12 weeks (1.53 +/- 0.42 vs. 2.47 +/- 0.63, p = 0.003) for the V-Flex stent. In conclusion, V-Flex coronary stent implantation in a porcine coronary and peripheral arteries results in a high procedural success rate without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six and 12 week histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia. Comparison with the Palmaz-Schatz coronary stent in a peripheral artery model showed significantly less neointimal hyperplasia in the V-Flex stent.

  2. Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction.

    PubMed

    Cho, Jae Hee; Jeon, Tae Joo; Park, Jeong Youp; Kim, Hee Man; Kim, Yoon Jae; Park, Seung Woo; Chung, Jae Bock; Song, Si Young; Bang, Seungmin

    2011-02-01

    The self-expandable metallic stent (SEMS) has been widely used for unresectable malignant biliary obstruction but eventually becomes occluded by tumor ingrowth/overgrowth and sludge. Therefore, we aimed to determine the therapeutic effectiveness of secondary stents and to find differences according to various combinations of the first and second stents for the management of occluded SEMSs in patients with malignant distal biliary obstruction. Between 1999 and November 2008, 77 patients with malignant biliary obstruction underwent secondary biliary stent placement as "stent-in-stent" at three university hospitals in Korea (40 covered, 26 uncovered, and 11 plastic stents). The membrane of the covered SEMS was regarded as the barrier against tumor ingrowth. We categorized the patients into three groups based on whether the covered SEMS was either the first or the second stent: membrane-SEMS (18 covered-covered; 9 covered-uncovered; 22 uncovered-covered SEMS), bare-SEMS (17 uncovered-uncovered SEMS), and plastic stent (3 covered-plastic; 8 uncovered-plastic). The median patency of second stents was 138, 109, and 88 days (covered, uncovered, and plastic stents). The second covered SEMSs had a significantly longer patency than plastic stents (p=0.047). In a multivariate analysis including membrane-SEMS, bare-SEMS, and plastic stent groups, the bare-SEMS had a worse cumulative stent patency (HR=2.04, CI=1.08-3.86) and survival time (HR=2.37, CI=1.25-4.49) than the membrane-SEMS. Patients with ampulla of Vater cancer had better stent patency (HR=0.27, CI=0.08-0.98) and survival (HR=0.17, CI=0.04-0.77) than those with other pancreatobiliary malignancies. In addition, antitumor treatment prolonged survival time (HR=0.50, CI=0.26-0.99). The placement of additional biliary stents using the "stent-in-stent" method is an effective treatment for an occluded metallic primary stent. In addition, double biliary SEMS placement using at least one covered SEMS (in the primary and/or secondary procedure) might provide longer cumulative stent patency and survival than using uncovered SEMSs in both procedures.

  3. The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent.

    PubMed

    Yu, Yi; Zhou, Yujie; Ma, Qian; Jia, Shuo; Wu, Sijing; Sun, Yan; Liu, Xiaoli; Zhao, Yingxin; Liu, Yuyang; Shi, Dongmei

    2017-01-15

    This study sought to explore the efficacy of the conical stent implantation in the coronary artery by comparing the effects of cylindrical and conical stents on wall shear stress (WSS) and velocity of flow and fractional flow reserve (FFR). The traditional cylindrical stent currently used in the percutaneous coronary intervention (PCI) has a consistent diameter, which does not match the physiological change of the coronary artery. On the contrary, as a new patent, the conical stent with tapering lumen is consistent with the physiological change of vascular diameter. However, the effect of the conical stent implantation on the coronary hemodynamics remains unclear. The coronary artery, artery stenosis and two stent models were established by Solidworks software. All models were imported into the computational fluid dynamics (CFD) software ANSYS ICEM-CFD to establish the fluid model. After the boundary conditions were set, CFD analysis was proceeded to compare the effects of two stent implantation on the change of WSS, velocity of flow and FFR. Hemodynamic indexes including FFR, blood flow velocity distribution (BVD) and WSS were improved by either the cylindrical or the conical stent implantation. However, after the conical stent implantation, the change of FFR seemed to be slower and more homogenous; the blood flow velocity was more appropriate without any obvious blood stagnation and direction changes; the WSS after the conical stent implantation was uniform from the proximal to distal side of the stent. Compared with the cylindrical stent, the conical stent implantation in the coronary artery can make the changes of vascular hemodynamic more closer to the physiological condition, which can reduce the incidence of intra-stent restenosis and thrombosis, thus making it more suitable for PCI therapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    PubMed

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as scientific data suggesting a lack of effectiveness, the authors argue that prophylactic intraoperative ureteral stenting should not be used in gynecologic surgery to decrease operative ureteric injury.

  5. Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty

    PubMed Central

    Pham, Thuy; Deherrera, Milton; Sun, Wei

    2013-01-01

    Recent clinical studies of the percutaneous transvenous mitral annuloplasty (PTMA) devices have shown a short-term reduction of mitral regurgitation (MR) after implantation. However, adverse events associated with the devices such as compression and perforation of vessel branches, device migration and fracture were reported. In this study, a finite element analysis was performed to investigate the biomechanical interaction between the proximal anchor stent of a PTMA device and the coronary sinus (CS) vessel in three steps including i) the stent release and contact with the CS wall, ii) the axial pull at the stent connector and iii) the pressure inflation of the vessel wall. To investigate the impact of the material properties of tissues and stents on the interactive responses, the CS vessel was modeled with human and porcine material properties, and the proximal stent was modeled with two different Nitinol materials with one being stiffer than the other. The results indicated that the vessel wall stresses and contact forces imposed by the stents were much higher in human than porcine models. However, the mechanical differences induced by the two stent types were relatively small. The softer stent exhibited a better fatigue safety factor when deployed in the human model than in the porcine model. These results underscored the importance of the CS tissue mechanical properties. Higher vessel wall stress and stent radial force were obtained in human model than those in porcine model, which also brought up questions as to the validity of using porcine model to assess device mechanical function. The quantification of these biomechanical interactions can offer scientific insight into the development and optimization of PTMA device design. PMID:23405942

  6. Wire-Interwoven Nitinol Stent Outcome in the Superficial Femoral and Proximal Popliteal Arteries: Twelve-Month Results of the SUPERB Trial.

    PubMed

    Garcia, Lawrence; Jaff, Michael R; Metzger, Christopher; Sedillo, Gino; Pershad, Ashish; Zidar, Frank; Patlola, Raghotham; Wilkins, Robert G; Espinoza, Andrey; Iskander, Ayman; Khammar, George S; Khatib, Yazan; Beasley, Robert; Makam, Satyaprakash; Kovach, Richard; Kamat, Suraj; Leon, Luis R; Eaves, William Britton; Popma, Jeffrey J; Mauri, Laura; Donohoe, Dennis; Base, Carol C; Rosenfield, Kenneth

    2015-05-01

    Stent-based therapy in the superficial femoral and popliteal arteries in patients with peripheral artery disease is compromised by restenosis and risk of stent fracture or distortion. A novel self-expanding nitinol stent was developed that incorporates an interwoven-wire design (Supera stent, IDEV Technologies, Inc, Webster, TX) to confer greater radial strength, flexibility, and fracture resistance. This prospective, multicenter, investigational device exemption, single-arm trial enrolled 264 patients with symptomatic peripheral artery disease undergoing percutaneous treatment of de novo or restenotic lesions of the superficial femoral or proximal popliteal (femoropopliteal) artery. Freedom from death, target lesion revascularization, or any amputation of the index limb at 30 days (+ 7 days) postprocedure was achieved in 99.2% (258/260) of patients (P < 0.001). Primary patency at 12 months (360 ± 30 days) was achieved in 78.9% (180/228) of the population (P < 0.001). Primary patency by Kaplan-Meier analysis at 12 months (360 days) was 86.3%. No stent fracture was observed by independent core laboratory analysis in the 243 stents (228 patients) evaluated at 12 months. Clinical assessment at 12 months demonstrated improvement by at least 1 Rutherford-Becker category in 88.7% of patients. The SUPERB Trial, an investigational device exemption study using an interwoven nitinol wire stent in the femoropopliteal artery, achieved the efficacy and safety performance goals predesignated by the Food and Drug Administration. On the basis of the high primary patency rate, absence of stent fracture, and significant improvements in functional and quality-of-life measures, the Supera stent provides safe and effective treatment of femoropopliteal lesions in symptomatic patients with peripheral artery disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00933270. © 2015 American Heart Association, Inc.

  7. Cost-utility analysis of stenting versus endarterectomy in the International Carotid Stenting Study.

    PubMed

    Morris, Stephen; Patel, Nishma V; Dobson, Joanna; Featherstone, Roland L; Richards, Toby; Luengo-Fernandez, Ramon; Rothwell, Peter M; Brown, Martin M

    2016-06-01

    The International Carotid Stenting Study was a multicenter randomized trial in which patients with symptomatic carotid artery stenosis were randomly allocated to treatment by carotid stenting or endarterectomy. Economic evidence comparing these treatments is limited and inconsistent. We compared the cost-effectiveness of stenting versus endarterectomy using International Carotid Stenting Study data. We performed a cost-utility analysis estimating mean costs and quality-adjusted life years per patient for both treatments over a five-year time horizon based on resource use data and utility values collected in the trial. Costs of managing stroke events were estimated using individual patient data from a UK population-based study (Oxford Vascular Study). Mean costs per patient (95% CI) were US$10,477 ($9669 to $11,285) in the stenting group (N = 853) and $9669 ($8835 to $10,504) in the endarterectomy group (N = 857). There were no differences in mean quality-adjusted life years per patient (3.247 (3.160 to 3.333) and 3.228 (3.150 to 3.306), respectively). There were no differences in adjusted costs between groups (mean incremental costs for stenting versus endarterectomy $736 (95% CI -$353 to $1826)) or adjusted outcomes (mean quality-adjusted life years gained -0.010 (95% CI -0.117 to 0.097)). The incremental net monetary benefit for stenting versus endarterectomy was not significantly different from zero at the maximum willingness to pay for a quality-adjusted life year commonly used in the UK. Sensitivity analyses showed little uncertainty in these findings. Economic considerations should not affect whether patients with symptomatic carotid stenosis undergo stenting or endarterectomy. © 2016 World Stroke Organization.

  8. Impact of Clinical Trial Results on the Temporal Trends of Carotid Endarterectomy and Stenting From 2002 to 2014

    PubMed Central

    Hussain, Mohamad A.; Mamdani, Muhammad; Tu, Jack V.; Saposnik, Gustavo; Khoushhal, Zeyad; Aljabri, Badr; Verma, Subdoh

    2016-01-01

    Background and Purpose— Randomized trials provide conflicting data for the efficacy of carotid-artery stenting compared with endarterectomy. The purpose of this study was to examine the impact of conflicting clinical trial publications on the utilization rates of carotid revascularization procedures. Methods— We conducted a population-level time-series analysis of all individuals who underwent carotid endarterectomy and stenting in Ontario, Canada (2002–2014). The primary analysis examined temporal changes in the rates of carotid revascularization procedures after publications of major randomized trials. Secondary analyses examined changes in overall and age, sex, carotid-artery symptom, and operator specialty–specific procedure rates. Results— A total of 16 772 patients were studied (14 394 endarterectomy [86%]; 2378 stenting [14%]). The overall rate of carotid revascularization decreased from 6.0 procedures per 100 000 individuals ≥40 years old in April 2002 to 4.3 procedures in the first quarter of 2014 (29% decrease; P<0.001). The rate of endarterectomy decreased by 36% (P<0.001), whereas the rate of carotid-artery stenting increased by 72% (P=0.006). We observed a marked increase (P=0.01) in stenting after publication of the SAPPHIRE trial (Stenting and Angioplasty With Protection in Patients at High Risk for Endarterectomy) in 2004, whereas stenting remained relatively unchanged after subsequent randomized trials published in 2006 (P=0.11) and 2010 (P=0.34). In contrast, endarterectomy decreased after trials published in 2006 (P=0.04) and 2010 (P=0.005). Conclusions— Although the overall rates of carotid revascularization and endarterectomy have fallen since 2002, the rate of carotid-artery stenting has risen since the publication of stenting-favorable SAPPHIRE trial. Subsequent conflicting randomized trials were associated with a decreasing rate of carotid endarterectomy. PMID:27834754

  9. Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis.

    PubMed

    Han, Xinwei; Al-Tariq, Quazi; Zhao, Yanle; Li, Lei; Cheng, Zhe; Wang, Huaqi; Liu, Chao; Jiao, Dechao; Wu, Gang

    2017-08-01

    To address the limitations of silicone stents, we designed a hinged self-expandable covered metallic stent. The aim of this study was to evaluate the safety and efficacy of the customized stents in clinical applications. This was a retrospective analysis. Under conscious sedation and local anesthesia, the stents were implanted or removed by interventional radiologists, with fluoroscopic guidance. Of 24 patients with benign main bronchial stenosis, stents were successfully placed in 21 (87.5%). The low-pressure balloon before dilation failed in 1 case (4.17%) of left main bronchial cicatricial stenosis. In 2 other cases (8.33%), stent placement was abandoned. Stents were successfully removed between 29 and 103 days after the procedure. After stent removal, the follow-up lasted for at least 12 months. Restenosis occurred only in 1 case (4.55%) owing to bronchial collapse 3 days after stent removal. Dyspnea occurred in another case (4.55%) at 2 months after retrieval; recurrence was confirmed using bronchoscopy, leading to a left pneumonectomy. The described procedure is safe and easy to be performed and avoids the use of intubation, bronchoscopy, and general anesthesia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

    PubMed Central

    Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado

    2015-01-01

    Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a low number of events. Trials had heterogeneity regarding investigation periods, baseline characteristics, and endpoint reporting, with a lack of information at long term follow-up. Direct and indirect evidence was also inconsistent for the comparison between drug eluting stents and drug coated balloons. What this study adds Compared with other currently available interventional treatments for coronary in-stent restenosis, drug coated balloons and drug eluting stents are associated with superior clinical and angiographic outcomes, with a similar comparative efficacy. Funding, competing interests, data sharing This study received no external funding. The authors declare no competing interests. No additional data available. PMID:26537292

  11. Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

    PubMed

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2014-01-01

    We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.

  12. [The application of Y-shaped self-expandable covered metal stents in the thoracostomach-airway fistula: a single center, 11 years experience].

    PubMed

    Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming

    2015-08-01

    To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.

  13. Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahlhelm, Frank, E-mail: frah1@gmx.de; Kaufmann, Ralf, E-mail: ralf.kaufmann@vascomed.d; Ahlhelm, Dirk, E-mail: ahlhelmd@gmx.de

    We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular interventionmore » as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.« less

  14. Risk factors for lower urinary tract infection and bacterial stent colonization in patients with a double J ureteral stent.

    PubMed

    Akay, Ali Ferruh; Aflay, Uğur; Gedik, Abdullah; Sahin, Hayrettin; Bircan, Mehmet Kamuran

    2007-01-01

    We investigated the potential risk factors for lower urinary tract infection and bacterial stent colonization in patients with double-J stents. A total of 195 double-J stents from 190 patients (95 men and 95 women, mean age 40.22 years) were examined. In all patients, prophylactic antimicrobial therapy was administered at the time of stenting. The stents and urine samples were removed aseptically and the proximal and distal tip segments of the stents were obtained. Three culture specimens were obtained from each stent segment and urine sample. Chi-square tests, odds ratio, and relative risk were used for the statistical analysis. Bacterial colonies were found in 24% (47 of 190) of the urine samples, 31% (61 of 195) of the proximal stent segments, and 34% (67 of 195) of the distal stent segments. Of the pathogens identified, Escherichia coli (34 of 47) was the most common. Diabetes mellitus (P < 0.01), chronic renal failure (P < 0.001), and pregnancy (P < 0.01) were found to be risk factors for lower urinary tract infection in patients with stents. An increased stent colonization rate was associated with implantation time, age, and female sex, but these were not statistically significant for lower urinary tract infection Diabetes mellitus, chronic renal failure, and pregnancy are associated with a higher risk of lower urinary tract infection. Therefore, patients in these categories should be monitored carefully for infectious complications.

  15. Patency of the Internal Iliac Artery after Placement of Common and External Iliac Artery Stents.

    PubMed

    Vinogradova, Margie; Lee, Hye Joon; Armstrong, Ehrin J; Laird, John; Humphries, Misty D

    2017-01-01

    Treatment of severe aortoiliac occlusive disease (AIOD) frequently requires long-segment stenting of the common and external iliac arteries (CIA and EIA, respectively). This study aims to analyze the patency of the internal iliac artery (IIA) after placement of a CIA and EIA stents across the orifice. A retrospective analysis of all patients who underwent de novo ipsilateral stent placement in the CIA and EIA between 2006 and 2013 was performed. Kaplan-Meier analysis was used to analyze patency of the IIA, and Cox proportional hazard models were used to identify characteristics associated with occlusion. We identified 77 patients and 93 limbs where ipsilateral CIA and EIA stents were placed. Preintervention angiographic review found 52 cases of a patent ipsilateral IIA where stents were placed across the origin of the IIA in 31 cases and staggered across the orifice in 20 limbs. Kaplan-Meier analysis demonstrated a 37% patency in limbs where the stent covered the IIA orifice compared to 78% patency in uncovered arteries (P = 0.04). New-onset buttock claudication developed in 4 patients, 2 with patent IIAs and 2 with occluded. New-onset impotence also developed in 3 patients with occluded IIA and 5 patients with patent IIAs. Placement of stents across the origin of the IIA may not result in immediate occlusion, but long-term patency of covered IIAs is decreased compared to uncovered IIAs. This study is limited by a small sample size, but when treating AIOD, coverage of the internal iliac origin should be avoided to maintain patency of the pelvic circulation. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Use of drug-eluting stents versus bare-metal stents in Korea: a cost-minimization analysis using population data.

    PubMed

    Suh, Hae Sun; Song, Hyun Jin; Jang, Eun Jin; Kim, Jung-Sun; Choi, Donghoon; Lee, Sang Moo

    2013-07-01

    The goal of this study was to perform an economic analysis of a primary stenting with drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients with acute myocardial infarction (AMI) admitted through an emergency room (ER) visit in Korea using population-based data. We employed a cost-minimization method using a decision analytic model with a two-year time period. Model probabilities and costs were obtained from a published systematic review and population-based data from which a retrospective database analysis of the national reimbursement database of Health Insurance Review and Assessment covering 2006 through 2010 was performed. Uncertainty was evaluated using one-way sensitivity analyses and probabilistic sensitivity analyses. Among 513 979 cases with AMI during 2007 and 2008, 24 742 cases underwent stenting procedures and 20 320 patients admitted through an ER visit with primary stenting were identified in the base model. The transition probabilities of DES-to-DES, DES-to-BMS, DES-to-coronary artery bypass graft, and DES-to-balloon were 59.7%, 0.6%, 4.3%, and 35.3%, respectively, among these patients. The average two-year costs of DES and BMS in 2011 Korean won were 11 065 528 won/person and 9 647 647 won/person, respectively. DES resulted in higher costs than BMS by 1 417 882 won/person. The model was highly sensitive to the probability and costs of having no revascularization. Primary stenting with BMS for AMI with an ER visit was shown to be a cost-saving procedure compared with DES in Korea. Caution is needed when applying this finding to patients with a higher level of severity in health status.

  17. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with criticalmore » limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.« less

  18. Large Bariatric-Specific Stents and Over-the-Scope Clips in the Management of Post-Bariatric Surgery Leaks.

    PubMed

    Shehab, Hany; Abdallah, Emad; Gawdat, Khaled; Elattar, Inas

    2018-01-01

    Endoscopic stents are successful in the management of surgical leaks; however, stent migration remains a significant problem. In this study, we present our approach depending on a large bariatrics-specific stent (Mega stent) and over-the-scope clips in the management of post-bariatric surgery leaks. A retrospective analysis of all patients with post-bariatric surgery leaks treated at our institution using an approach reliant on Mega stents and over-the-scope clips was conducted. Potential factors associated with procedure success and occurrence of complications were also evaluated. A total of 81 stents were inserted in 62 patients with post-bariatric surgery leaks, 46 sleeve gastrectomies (73%) and 16 Roux-en-Y gastric bypass (27%). Over-the-scope clips were applied in 29 patients (46%). Leak closure was achieved in 51 patients (82%). Median number of procedures per patient was 3 (range 2-8). Complications included the following: stent migration (11/62, 18%), intolerance necessitating premature removal (7/62, 11%), esophageal stricture (8/62, 13%), bleeding (4/62, 6%), perforation (4/62, 6%). One stent-induced mortality was encountered (bleeding). The presence of open surgery (vs laparoscopic) was significantly associated with the occurrence of stent-induced complications (p 0.002). The approach combining Mega stents and over-the-scope clips is highly effective in the management of post-bariatric surgery leaks and is associated with a low rate of stent migration and a low number of procedures and stents per patient. Mega stents, however, should be used with great caution due to the significant morbidity associated with their use.

  19. Stent Design Affects Femoropopliteal Artery Deformation.

    PubMed

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  20. Optimization of stent implantation using a high pressure inflation protocol.

    PubMed

    Vallurupalli, Srikanth; Bahia, Amit; Ruiz-Rodriguez, Ernesto; Ahmed, Zubair; Hakeem, Abdul; Uretsky, Barry F

    2016-01-01

    High-pressure inflation is the universal standard for stent deployment but a specific protocol for its use is lacking. We developed a standardized "pressure optimization protocol" (POP) using time to inflation pressure stability as an endpoint for determining the required duration of stent inflation. The primary study purpose was to determine the stent inflation time (IT) in a large patient cohort using the standardized inflation protocol, to correlate various patient and lesion characteristics with IT, and ascertain in an in vitro study the time for pressure accommodation within an inflation system. Six hundred fifteen stent implants in 435 patients were studied. Multivariate analysis was performed to determine predictors of longer ITs. In an in vitro study, various stents and balloons were inflated in air to determine the pressure accommodation time of the inflation system. The mean stent IT was 104 ± 41 sec (range 30-380 sec). Stent length was the only predictor of prolonged stent inflation. The "accommodation time" in vitro of the stent inflation system itself was 33 ± 24 sec. The protocol was safe requiring premature inflation termination in <3% of stent implants. No serious adverse events occurred. Achieving stable inflation pressure requires on average over 100 sec and may require several minutes in individual cases. Stent length increases IT. These results suggest that the widespread practice of rapid inflation/deflation may not be sufficient to fully expand the stent and that the use of a pressure stability protocol will allow for safe, predictable, and more complete stent deployment. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  1. Protection or nonprotection in carotid stent angioplasty: the influence of interventional techniques on outcome data from the SPACE Trial.

    PubMed

    Jansen, Olav; Fiehler, Jens; Hartmann, Marius; Brückmann, Hartmut

    2009-03-01

    The use of protection devices (PDs) and stents with different cell designs in carotid artery stenting (CAS) is a subject of controversy, and no data on their benefit are available from independently controlled multi-center studies. We analyzed data from the prospective randomized SPACE trial, which included 563 patients randomized to CAS and treated per protocol. A total of 145 patients were treated with a PD and 418 without. Of the patients, 436 were treated with an open cell stent and 127 with a closed cell stent. Use of PDs and choice of device was chosen at the individual discretion of the interventionalist. The outcome event (OE) of the analysis (ipsilateral stroke or ipsilateral stroke death within 30 days) was reached in 26/418 patients (6.2%, 95% CI: 4.1 to 9.0%) in the nonprotection [corrected] group and in 12/145 (8.3%, 95% CI: 4.3 to 14.0%) patients in the protection [corrected] group (P=0.40). The OE rate was significantly lower in patients treated with a closed cell stent (5.6% [95% CI: 3.7 to 8.2%]) than in those treated with an open cell stent.(11.0%, 95% CI: 6.2 to 17.8%; P=0.029). Predilatation showed a tendency to but no significant reduction of OE rate. Overall, 49% of all OEs occurred directly periinterventionally, 10% during the navigation procedure and 41% postinterventionally, including 10% of hyperperfusion syndromes. Time point of the event was not influenced by the use of a PD. This secondary analysis of data from the SPACE trial does not support the need for a PD in CAS. Stent design seems to have an impact on the OE rate. Our analysis demonstrates that the choice of the interventional material may have an impact on the periprocedural complication rate in CAS and that the development of more specific stent systems for the treatment of carotid stenosis may reduce the complication rate significantly.

  2. Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the Pipeline device.

    PubMed

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-07-02

    The aim of this study was to quantify the effect of the new Low-profile Visualized Intraluminal Support (LVIS®D) device and the difference of fluid diverting effect compared with the Pipeline device and the Enterprise stent using computational fluid dynamics (CFD). In this research, we simulated three aneurysms constructed from 3D digital subtraction angiography (DSA). The Enterprise, LVIS and the Pipeline device were virtually conformed to fit into the vessel lumen and placed across the aneurysm orifice. Computational fluid dynamics analysis was performed to compare the hemodynamic differences such as WSS, Velocity and Pressure among these stents. Control referred to the unstented model, the percentage of hemodynamic changes were all compared to Control. A single LVIS stent caused more wall shear stress reduction than double Enterprise stents (39.96 vs. 30.51 %) and velocity (23.13 vs. 18.64 %). Significant reduction in wall shear stress (63.88 %) and velocity (46.05 %) was observed in the double-LVIS stents. A single Pipeline showed less reduction in WSS (51.08 %) and velocity (37.87 %) compared with double-LVIS stent. The double-Pipeline stents resulted in the most reduction in WSS (72.37 %) and velocity (54.26 %). Moreover, the pressure increased with minuscule extent after stenting, compared with the unstented model. This is the first study analyzing flow modifications associated with LVIS stents. We found that the LVIS stent has certain hemodynamic effects on cerebral aneurysms: a single LVIS stent caused more flow reductions than the double-Enterprise stent but less than a Pipeline device. Nevertheless, the double-LVIS stent resulted in a better flow diverting effect than a Pipeline device.

  3. Ureteric stent dwelling time: a risk factor for post-ureteroscopy sepsis.

    PubMed

    Nevo, Amihay; Mano, Roy; Baniel, Jack; Lifshitz, David A

    2017-07-01

    To evaluate the association between stent dwelling time and sepsis after ureteroscopy, and identify risk factors for sepsis in this setting. The prospectively collected database of a single institution was queried for all patients who underwent ureteroscopy for stone extraction between 2010 and 2016. Demographic, clinical, preoperative and operative data were collected. The primary study endpoint was sepsis within 48 h of ureteroscopy. Logistic regressions were performed to identify predictors of post-ureteroscopy sepsis in the ureteroscopy cohort and specifically in patients with prior stent insertion. Between October 2010 and April 2016, 1 256 patients underwent ureteroscopy for stone extraction. Risk factors for sepsis included prior stent placement, female gender and Charlson comorbidity index. A total of 601 patients had a ureteric stent inserted before the operation and were included in the study cohort, in which the median age was 56 years, 90 patients were women (30%), and 97 patients were treated for positive preoperative urine cultures (16.1%). Postoperative sepsis, <48 h after surgery, occurred in eight (1.2%) non-stented patients and in 28 patients (4.7%) with prior stent insertion. Sepsis rates after stent dwelling times of 1, 2, 3 and >3 months were 1, 4.9, 5.5 and 9.2%, respectively. On multivariate analysis, stent dwelling time, stent insertion because of sepsis, and female gender were significantly associated with post-ureteroscopy sepsis in patients with prior stent placement. Patients who undergo ureteroscopy after ureteric stent insertion have a higher risk of postoperative sepsis. Prolonged stent dwelling time, sepsis as an indication for stent insertion, and female gender are independent risk factors. Stent placement should be considered cautiously, and if inserted, ureteroscopy should be performed within 1 month. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  4. Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma.

    PubMed

    Chung, Kwang Hyun; Lee, Sang Hyub; Park, Jin Myung; Lee, Jae Min; Ahn, Dong-Won; Ryu, Ji Kon; Kim, Yong-Tae

    2015-06-01

    The patency of self-expandable metallic stents (SEMS) is known to be better than plastic stents in the palliation of malignant biliary obstruction. However, data are scarce for obstructive jaundice caused by hepatocellular carcinoma (HCC). This study aimed to compare SEMSs and plastic stents for the palliation of obstructive jaundice in unresectable HCC. A total of 96 patients who underwent endoscopic retrograde biliary drainage with SEMSs or plastic stents were included in this retrospective analysis. The rate of successful biliary drainage, adverse events, stent patency duration, and patient survival were compared between the SEMS (n = 36) and plastic stent (n = 60) groups. The rate of successful biliary drainage was similar between the SEMS and plastic stent groups (25/36 [69.4 %] vs. 39/60 [65.0 %]; P = 0.655). Adverse events occurred in 6 patients (16.7 %) in the SEMS group and 13 patients (21.7 %) in the plastic stent group (P = 0.552). The median patency duration was also similar between the two groups (60 vs. 68 days; P = 0.396). The median patient survival was longer in the plastic stent group than in the SEMS group (123 vs. 48 days; P = 0.005). SEMSs were not superior to plastic stents for the palliation of malignant biliary obstruction in HCC with regard to successful drainage, stent patency, and adverse events. Patient survival was better in the plastic stent group. Given the lower cost, plastic stents could be a favorable option for malignant biliary obstruction caused by HCC. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Effects of plaque lengths on stent surface roughness.

    PubMed

    Syaifudin, Achmad; Takeda, Ryo; Sasaki, Katsuhiko

    2015-01-01

    The physical properties of the stent surface influence the effectiveness of vascular disease treatment after stent deployment. During the expanding process, the stent acquires high-level deformation that could alter either its microstructure or the magnitude of surface roughness. This paper constructed a finite element simulation to observe the changes in surface roughness during the stenting process. Structural transient dynamic analysis was performed using ANSYS, to identify the deformation after the stent is placed in a blood vessel. Two types of bare metal stents are studied: a Palmaz type and a Sinusoidal type. The relationship between plaque length and the changes in surface roughness was investigated by utilizing three different length of plaque; plaque length longer than the stent, shorter than the stent and the same length as the stent. In order to reduce computational time, 3D cyclical and translational symmetry was implemented into the FE model. The material models used was defined as a multilinear isotropic for stent and hyperelastic for the balloon, plaque and vessel wall. The correlation between the plastic deformation and the changes in surface roughness was obtained by intermittent pure tensile test using specimen whose chemical composition was similar to that of actual stent material. As the plastic strain is achieved from FE simulation, the surface roughness can be assessed thoroughly. The study found that the plaque size relative to stent length significantly influenced the critical changes in surface roughness. It was found that the length of stent which is equal to the plaque length was preferable due to the fact that it generated only moderate change in surface roughness. This effect was less influential to the Sinusoidal stent.

  6. Neurovascular stent artifacts in 3D-TOF and 3D-PCMRI: Influence of stent design on flow measurement.

    PubMed

    Bouillot, Pierre; Brina, Olivier; Delattre, Bénédicte M A; Ouared, Rafik; Pellaton, Alain; Yilmaz, Hasan; Machi, Paolo; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes; Vargas, Maria Isabel

    2018-06-12

    The morphological and hemodynamic evaluations of neurovascular diseases treated with stents would benefit from noninvasive imaging techniques such as 3D time-of-flight MRI (3D-TOF) and 3D phase contrast MRI (3D-PCMRI). For this purpose, a comprehensive evaluation of the stent artifacts and their impact on the flow measurement is critical. The artifacts of a representative sample of neurovascular stents were evaluated in vitro with 3D-TOF and 3D-PCMRI sequences. The dependency of the artifacts with respect to the orientation was analyzed for each stent design as well as the impact on the flow measurement accuracy. Furthermore, the 3D-PCMRI data of four patients carrying intracranial aneurysms treated with flow diverter stents were analyzed as illustrative examples. The stent artifacts were mainly confined to the stent lumen therefore indicating the leading role of shielding effect. The influence of the stent design and its orientation with respect to the transmitting MR coils were highlighted. The artifacts impacted the 3D-PCMRI velocities mainly in the low magnitude domains, which were discarded from the analysis ensuring reliable near-stent velocities. The feasibility of in-stent flow measurements was confirmed in vivo on two patients who showed strong correlation between flow and geometric features. In two other patients, the consistency of out-of-stent velocities was verified qualitatively through intra-aneurysmal streamlines except when susceptibility artifacts occurred. The present results motivate the conception of low inductance or nonconductive stent design. Furthermore, the feasibility of near-stent 3D-PCMRI measurements opens the door to clinical applications like the post-treatment follow-up of stenoses or intracranial aneurysms. © 2018 International Society for Magnetic Resonance in Medicine.

  7. Comparative Study of Esophageal Stent and Feeding Gastrostomy/Jejunostomy for Tracheoesophageal Fistula Caused by Esophageal Squamous Cell Carcinoma

    PubMed Central

    Chiu, Yi-Chun; Lu, Hung-I; Huang, Cheng-Hua; Rau, Kun-Ming; Liu, Chien-Ting

    2012-01-01

    Background A malignant tracheoesophageal/bronchoesophageal fistula (TEF) is a life-threatening complication of esophageal squamous cell carcinoma. A feeding gastrostomy/jejunostomy had been the most common treatment method for patients with TEF before the era of stenting. The aim of this retrospective study is to compare the prognosis of esophageal squamous cell carcinoma patients with TEF treated with an esophageal metallic stent to those treated with a feeding gastrostomy/jejunostomy. Methods We retrospectively reviewed a total of 1011 patients with esophageal squamous cell carcinoma between 1996 and 2011 at Kaohsiung Chang Gung Memorial Hospital, and 86 patients with TEF (8.5%) were identified. The overall survival and other clinical data were compared between 30 patients treated with an esophageal metallic stent and 35 patients treated with a feeding gastrostomy/jejunostomy. Results Among the 65 patients receiving either an esophageal metallic stent or a feeding gastrostomy/jejunostomy, univariate analysis showed that treatment modality with an esophageal metallic stent (P = 0.007) and radiotherapy treatment after fistula diagnosis (P = 0.04) were predictive of superior overall survival. In the multivariate comparison, treatment modality with an esophageal metallic stent (P = 0.026, odds ratio: 1.859) represented the independent predictive factor of superior overall survival. There were no significant differences between groups in mean decrease in serum albumin or mean body weight loss. Compared to the feeding gastrostomy/jejunostomy group, a significantly higher proportion of patients in the stenting group (53% versus 14%, P = 0.001) were able to receive chemotherapy within 30 days after fistula diagnosis, indicating better infection control in the stenting group. Conclusions Compared with a feeding gastrostomy/jejunostomy, an esophageal metallic stent significantly improves overall survival in patients with malignant TEF in our retrospective analysis. Esophageal metallic stent placement may be considered the first-line of treatment for patients with malignant TEF. PMID:22912737

  8. Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics

    PubMed Central

    Bernardini, Annarita; Larrabide, Ignacio; Morales, Hernán G.; Pennati, Giancarlo; Petrini, Lorenza; Cito, Salvatore; Frangi, Alejandro F.

    2011-01-01

    Cerebral aneurysms are abnormal focal dilatations of artery walls. The interest in virtual tools to help clinicians to value the effectiveness of different procedures for cerebral aneurysm treatment is constantly growing. This study is focused on the analysis of the influence of different stent deployment approaches on intra-aneurysmal haemodynamics using computational fluid dynamics (CFD). A self-expanding stent was deployed in an idealized aneurysmatic cerebral vessel in two initial positions. Different cases characterized by a progression of simplifications on stent modelling (geometry and material) and vessel material properties were set up, using finite element and fast virtual stenting methods. Then, CFD analysis was performed for untreated and stented vessels. Haemodynamic parameters were analysed qualitatively and quantitatively, comparing the cases and the two initial positions. All the cases predicted a reduction of average wall shear stress and average velocity of almost 50 per cent after stent deployment for both initial positions. Results highlighted that, although some differences in calculated parameters existed across the cases based on the modelling simplifications, all the approaches described the most important effects on intra-aneurysmal haemodynamics. Hence, simpler and faster modelling approaches could be included in clinical workflow and, despite the adopted simplifications, support clinicians in the treatment planning. PMID:22670204

  9. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    PubMed

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p < 0.001). G2-DES were associated with a similar risk of stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p < 0.001), but not with G2-DES compared with BMS (OR: 1.01; 95% CI: 0.32 to 3.25; p = 0.98). In a large cohort of unselected patients undergoing coronary stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Aspirin Use Is Associated With Reduced Risk of Occlusion of Metallic Biliary Stents.

    PubMed

    Jang, Sunguk; Stevens, Tyler; Parsi, Mansour A; Lopez, Rocio; Vargo, John J

    2017-03-01

    Biliary self-expandable metallic stents (SEMSs) are widely used to treat malignant and benign conditions of bile duct. Despite their lower rate of occlusion and longer patency than plastic stents, SEMSs still have significant rates of occlusion. We aimed to identify factors associated with occlusion of biliary SEMS. We performed a retrospective study of consecutive patients who underwent endoscopic retrograde cholangiopancreatography with biliary SEMS placement at the Cleveland Clinic Foundation from March 2011 to April 2016. We collected clinical, endoscopic, radiographic, and surgical data from medical records and performed multivariable analysis to identify factors associated with SEMS patency. Subjects that received minimal daily dose of 81 mg at the time of stent placement until the end of follow-up were assigned to the aspirin exposure group (n = 157) and compared with subjects with no aspirin exposure (n = 436). Patients were followed for a median 81 days. The primary outcome was hazard ratio for SEMS occlusion requiring an interventional maneuver for biliary drainage. We analyzed data from patients receiving a total of 593 biliary SEMS for treatment of malignant and benign conditions of bile duct. Stent occlusion was observed in 126 cases. Multivariable analysis showed that daily use of aspirin (81 mg or more) was associated with 51% lower risk of stent occlusion than in patients without daily use of aspirin (hazard ratio, 0.49; 95% confidence interval, 0.32-0.75). Furthermore, SEMSs had a longer duration of stent patency in patients in the aspirin exposure group (434.4 days) versus the no aspirin exposure group (339.9 days) (P < .001). Stricture location limited to distal bile duct (in comparison with strictures involving proximal extrahepatic duct) was associated with lower risk of stent occlusion (hazard ratio, 0.39; 95% CI, 0.22-0.71). In an analysis of a large cohort of subjects with metallic biliary stent placement for malignant and benign conditions of bile duct, we associated daily use of aspirin (81 mg or more) with lower risk of SEMS occlusion and longer stent patency duration. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  11. Quantifying the bias in the estimated treatment effect in randomized trials having interim analyses and a rule for early stopping for futility.

    PubMed

    Walter, S D; Han, H; Briel, M; Guyatt, G H

    2017-04-30

    In this paper, we consider the potential bias in the estimated treatment effect obtained from clinical trials, the protocols of which include the possibility of interim analyses and an early termination of the study for reasons of futility. In particular, by considering the conditional power at an interim analysis, we derive analytic expressions for various parameters of interest: (i) the underestimation or overestimation of the treatment effect in studies that stop for futility; (ii) the impact of the interim analyses on the estimation of treatment effect in studies that are completed, i.e. that do not stop for futility; (iii) the overall estimation bias in the estimated treatment effect in a single study with such a stopping rule; and (iv) the probability of stopping at an interim analysis. We evaluate these general expressions numerically for typical trial scenarios. Results show that the parameters of interest depend on a number of factors, including the true underlying treatment effect, the difference that the trial is designed to detect, the study power, the number of planned interim analyses and what assumption is made about future data to be observed after an interim analysis. Because the probability of stopping early is small for many practical situations, the overall bias is often small, but a more serious issue is the potential for substantial underestimation of the treatment effect in studies that actually stop for futility. We also consider these ideas using data from an illustrative trial that did stop for futility at an interim analysis. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Intravascular Ultrasound to Guide Percutaneous Coronary Interventions

    PubMed Central

    2006-01-01

    Executive Summary Objective The objective of this health technology policy assessment was to determine the effectiveness and cost-effectiveness of using intravascular ultrasound (IVUS) as an adjunctive imaging tool to coronary angiography for guiding percutaneous coronary interventions. Background Intravascular Ultrasound Intravascular ultrasound is a procedure that uses high frequency sound waves to acquire 3-dimensional images from the lumen of a blood vessel. The equipment for performing IVUS consists of a percutaneous transducer catheter and a console for reconstructing images. IVUS has been used to study the structure of the arterial wall and nature of atherosclerotic plaques, and obtain measurements of the vessel lumen. Its role in guiding stent placement is also being investigated. IVUS is presently not an insured health service in Ontario. Clinical Need Coronary artery disease accounts for approximately 55% of cardiovascular deaths, the leading cause of death in Canada. In Ontario, the annual mortality rate due to ischemic heart disease was 141.8 per 100,000 population between 1995 and 1997. Percutaneous coronary intervention (PCI), a less invasive approach to treating coronary artery disease, is used more frequently than coronary bypass surgery in Ontario. The number of percutaneous coronary intervention procedures funded by the Ontario Ministry of Health and Long-term Care is expected to increase from approximately 17, 780 in 2004/2005 to 22,355 in 2006/2007 (an increase of 26%), with about 95% requiring the placement of one or more stents. Restenosis following percutaneous coronary interventions involving bare metal stents occurs in 15% to 30% of the cases, mainly because of smooth muscle proliferation and migration, and production of extracellular matrix. In-stent restenosis has been linked to suboptimal stent expansion and inadequate lesion coverage, while stent thrombosis has been attributed to incomplete stent-to-vessel wall apposition. Since coronary angiography (the imaging tool used to guide stent placement) has been shown to be inaccurate in assessing optimal stent placement, and IVUS can provide better views of the vessel lumen, the clinical utility of IVUS as an imaging tool adjunctive to coronary angiography in coronary intervention procedures has been explored in clinical studies. Method A systematic review was conducted to answer the following questions: What are the procedure-related complications associated with IVUS? Does IVUS used in conjunction with angiography to guide percutaneous interventions improve patient outcomes compared to angiographic guidance without IVUS? Who would benefit most in terms of clinical outcomes from the use of IVUS adjunctive to coronary angiography in guiding PCIs? What is the effectiveness of IVUS guidance in the context of drug-eluting stents? What is the cost-effectiveness ratio and budget impact of adjunctive IVUS in PCIs in Ontario? A systematic search of databases OVID MEDLINE, EMBASE, MEDLINE In-Process & Other Non-Indexed Citations, The Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) database for the period beginning in May 2001 until the day of the search, November 4, 2005 yielded 2 systematic reviews, 1 meta-analysis, 6 randomized controlled trials, and 2 non-randomized studies on left main coronary arteries. The quality of the studies ranged from moderate to high. These reports were combined with reports from a previous systematic review for analysis. In addition to qualitative synthesis, pooled analyses of data from randomized controlled studies using a random effect model in the Cochrane Review Manager 4.2 software were conducted when possible. Findings of Literature Review & Analysis Safety Intravascular ultrasound appears to be a safe tool when used in coronary interventions. Periprocedural complications associated with the use of IVUS in coronary interventions ranged from 0.5% in the largest study to 4%. Coronary rupture was reported in 1 study (1/54). Other complications included prolonged spasms of the artery after stenting, dissection, and femoral aneurysm. Effectiveness Based on pooled analyses of data from randomized controlled studies, the use of intravascular ultrasound adjunctive to coronary intervention in percutaneous coronary interventions using bare metal stents yielded the following findings: For lesions predominantly at low risk of restenosis: There were no significant differences in preintervention angiographic minimal lumen diameter between the IVUS-guided and angiography-guided groups. IVUS guidance resulted in a significantly larger mean postintervention angiographic minimal lumen diameter (weighted mean difference of 0.11 mm, P = .0003) compared to angiographic guidance alone. The benefit in angiographic minimal lumen diameter from IVUS guidance was not maintained at 6-month follow-up, when no significant difference in angiographic minimal lumen diameter could be detected between the two arms (weighted mean difference 0.08, P = .13). There were no statistically significant differences in angiographic binary restenosis rates between IVUS-guidance and no IVUS guidance (Odds ratio [OR] 0.87 in favour of IVUS, 95% Confidence Interval [CI] [0.64–1.18], P = 0.37). IVUS guidance resulted in a reduction in the odds of target lesion revascularization (repeat percutaneous coronary intervention or coronary bypass graft) compared to angiographic guidance alone. The reduction was statistically significant at a follow-up period of 6 months to 1 year, and at a follow-up period of 18 month to 2 years (OR 0.52 in favour of IVUS, 95% CI [0.33–0.81], P = .004). Total revascularization rate (either target lesion or target vessel revascularization) was significantly lower for IVUS-guided patients at 18 months to 2.5 years after intervention (OR 0.43 in favour of IVUS, 95% CI [0.29–0.63], p < .0001). There were no statistically significant differences in the odds of death (OR 1.36 in favour of no IVUS, P =0.65) or myocardial infarction (OR 0.95 in favour of IVUS, P = 0.93) between IVUS-guidance and angiographic guidance alone at up to 2.5 years of follow-up The odds of having a major cardiac event (defined as death, myocardial infarction, and target lesion or target vessel revascularization) were significantly lower for patients with IVUS guidance compared to angiographic guidance alone during follow-up periods of up to 2.5 years (OR 0.53, 95% CI [0.36–0.78], P = 0.001). Since there were no significant reductions in the odds of death or myocardial infarction, the reduction in the odds of combined events reflected mainly the reduction in revascularization rates. For lesions at High Risk of Restenosis: There is evidence from one small, randomized controlled trial (n=150) that IVUS-guided percutaneous coronary intervention in long de novo lesions (>20 mm) of native coronary arteries resulted in statistically significant larger minimal lumen Diameter, and statistically significant lower 6-month angiographic binary restenosis rate. Target vessel revascularization rate and the rate of combined events were also significantly reduced at 12 months. A small subgroup analysis of a randomized controlled trial reported no benefit in clinical or angiographic outcomes for IVUS-guided percutaneous coronary interventions in patients with diabetes compared to those guided by angiography. However, due to the nature and size of the analysis, no firm conclusions could be reached. Based on 2 small, prospective, non-randomized controlled studies, IVUS guidance in percutaneous coronary interventions of left main coronary lesions using bare metal stents or drug-eluting stents did not result in any benefits in angiographic or clinical outcomes. These findings need to be confirmed. Interventions Using Drug-Eluting Stents There is presently no evidence on whether the addition of IVUS guidance during the implantation of drug-eluting stents would reduce incomplete stent apposition, or improve the angiographic or clinical outcomes of patients. Ontario-Based Economic Analysis Cost-effectiveness analysis showed that PCIs using IVUS guidance would likely be less costly and more effective than PCIs without IVUS guidance. The upfront cost of adjunctive use of IVUS in PCIs ranged from $1.56 million at 6% uptake to $13.04 million at 50% uptake. Taking into consideration cost avoidance from reduction in revascularization associated with the use of IVUS, a net saving of $0.63 million to $5.2 million is expected. However, since it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS can be generalized to clinical settings in Ontario, further analysis on the budget impact and cost-effectiveness need to be conducted once Ontario-specific revascularization rates are verified. Factors to be Considered in the Ontario Context Applicability of Findings to Ontario The interim analysis of an Ontario field evaluation that compared drug-eluting stents to bare metal stents showed that the revascularization rates in low-risk patients with bare metal stents were much lower in Ontario compared to rates reported in randomized controlled trials (7.2% vs >17 %). Even though IVUS is presently not routinely used in the stenting of low-risk patients in Ontario, the revascularization rates in these patients in Ontario were shown to be lower than those reported for the IVUS groups reported in published studies. Based on this information and previous findings from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rates from IVUS guidance can be generalized to Ontario. In light of the above findings, it is advisable to validate the reported benefits of IVUS guidance in percutaneous coronary interventions involving bare metal stents in the Ontario context. Licensing Status As of January 16, 2006, Health Canada has licensed 10 intravascular ultrasound imaging systems/catheters for transluminal intervention procedures, most as class 4 medical devices. Current Funding IVUS is presently not an insured procedure under the Ontario Health Insurance Plan and there are no professional fees for this procedure. All costs related to the use of IVUS are covered within hospitals’ global budgets. A single use IVUS catheter costs approximately $900CDN and the procedure adds approximately 20 minutes to 30 minutes to a percutaneous coronary intervention procedure. Diffusion According to an expert consultant, current use of IVUS in coronary interventions in Ontario is probably limited to high-risk cases such as interventions in long lesions, small vessels, and bifurcated lesions for which images from coronary angiography are indeterminate. It was estimated that IVUS is being used in about 6% of all percutaneous coronary interventions at a large Ontario cardiac centre. Expert Opinion IVUS greatly enhances the cardiac interventionists’ ability to visualize and assess high-risk lesions such as long lesions, narrow lesions, and bifurcated lesions that may have indeterminate angiographic images. Information from IVUS in these cases facilitates the choice of the most appropriate approach for the intervention. Conclusion The use of adjunctive IVUS in PCIs using bare metal stents in lesions predominantly at low risk for restenosis had no significant impact on survival, myocardial infarction, or angiographic restenosis rates up to 2.5 years after intervention. The use of IVUS adjunctive to coronary angiography in percutaneous coronary interventions using bare metal stents in lesions predominantly at low risk for restenosis significantly reduced the target lesion and target vessel revascularization at a follow-up period of 18 months to 2.5 years. One small study suggests that adjunctive IVUS in PCIs using bare metal stents in long lesions (>20 mm) significantly improved the 6-month angiographic restenosis rate and one-year target lesion revascularization rate. These results need to be confirmed with large randomized controlled trials. Based on information from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS in the placement of bare metal stents can be generalized to clinical settings in Ontario. There is presently insufficient evidence available to determine the impact of adjunctive IVUS in percutaneous interventions in high-risk lesions (other than long lesions) or in PCIs using drug-eluting stents. PMID:23074482

  13. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis.

    PubMed

    Li, Jinjin; Li, Tong; Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19-4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05-10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57-1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94-1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56-0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12-0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03-3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54-34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36-4.50; p = 0.003, I2 = 0%). Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary obstruction due to their removability.

  14. Assessment of In-Stent Restenosis Using 64-MDCT: Analysis of the CORE-64 Multicenter International Trial

    PubMed Central

    Wykrzykowska, Joanna J.; Arbab-Zadeh, Armin; Godoy, Gustavo; Miller, Julie M.; Lin, Shezhang; Vavere, Andrea; Paul, Narinder; Niinuma, Hiroyuki; Hoe, John; Brinker, Jeffrey; Khosa, Faisal; Sarwar, Sheryar; Lima, Joao; Clouse, Melvin E.

    2012-01-01

    OBJECTIVE Evaluations of stents by MDCT from studies performed at single centers have yielded variable results with a high proportion of unassessable stents. The purpose of this study was to evaluate the accuracy of 64-MDCT angiography (MDCTA) in identifying in-stent restenosis in a multicenter trial. MATERIALS AND METHODS The Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography Using 64 Detectors (CORE-64) Multicenter Trial and Registry evaluated the accuracy of 64-MDCTA in assessing 405 patients referred for coronary angiography. A total of 75 stents in 52 patients were assessed: 48 of 75 stents (64%) in 36 of 52 patients (69%) could be evaluated. The prevalence of in-stent restenosis by quantitative coronary angiography (QCA) in this subgroup was 23% (17/75). Eighty percent of the stents were ≤ 3.0 mm in diameter. RESULTS The overall sensitivity, specificity, positive predictive value, and negative predictive value to detect 50% in-stent stenosis visually using MDCT compared with QCA was 33.3%, 91.7%, 57.1%, and 80.5%, respectively, with an overall accuracy of 77.1% for the 48 assessable stents. The ability to evaluate stents on MDCTA varied by stent type: Thick-strut stents such as Bx Velocity were assessable in 50% of the cases; Cypher, 62.5% of the cases; and thinner-strut stents such as Taxus, 75% of the cases. We performed quantitative assessment of in-stent contrast attenuation in Hounsfield units and correlated that value with the quantitative percentage of stenosis by QCA. The correlation coefficient between the average attenuation decrease and ≥ 50% stenosis by QCA was 0.25 (p = 0.073). Quantitative assessment failed to improve the accuracy of MDCT over qualitative assessment. CONCLUSION The results of our study showed that 64-MDCT has poor ability to detect in-stent restenosis in small-diameter stents. Evaluability and negative predictive value were better in large-diameter stents. Thus, 64-MDCT may be appropriate for stent assessment in only selected patients. PMID:20028909

  15. Pancreatic stent insertion after an unintentional guidewire cannulation of the pancreatic duct during ERCP.

    PubMed

    García-Cano, Jesús; Viñuelas Chicano, Miriam; Del Moral Martínez, María; Muñiz Muñoz, Marta; Murillo Matamoros, Claudio; Suárez Matías, Miguel; Valiente González, Laura; Martínez Pérez, Teresa; Martínez Fernández, Raquel; Gómez Ruiz, Carmen Julia; Pérez García, José Ignacio; Morillas Ariño, Julia

    2018-04-24

    the guidewire (GW) may enter the pancreatic duct during common bile duct (CBD) cannulation attempts in endoscopic retrograde cholangiopancreatography (ERCP). After GW passage into the pancreas, the most effective maneuver for CBD cannulation and pancreatitis prevention has not been determined. to study CBD cannulation and post-ERCP pancreatitis rates when a pancreatic stent is inserted after an unintentional GW cannulation of the pancreatic duct. a retrospective analysis of patients undergoing ERCP for biliary drainage that were included prospectively into a database. After unintentional GW cannulation of the pancreatic duct, a straight 5-Fr and 4-cm long plastic stent was inserted. The stents had no internal flaps to facilitate expulsion. CBD cannulation attempts were made above the stent. A pancreatic sphincterotomy was performed in patients older than 60 years before stent insertion. a total of 46 pancreatic stents were inserted during 154 ERCP (29.8%) procedures. In the stent group, CBD cannulation was accomplished in 44/46 (95.6%) subjects. A total of 21/46 (45.6%) pancreatic sphincterotomies were performed. Only 1/46 (2.17%) mild pancreatitis cases were observed and most stents were spontaneously expelled. in this study, the CBD was eventually reached with the insertion of a plastic pancreatic stent after an unintentional GW passage into the pancreatic duct while attempting a CBD cannulation. No adverse events were observed following pancreatic stent insertion.

  16. Design Investigation on Applicable Mesh Structures for Medical Stent Applications

    NASA Astrophysics Data System (ADS)

    Asano, Shoji; He, Jianmei

    2017-11-01

    In recent years, utilization of medical stents is one of effective treatments for stenosis and occlusion occurring in a living body’s lumen indispensable for maintenance of human life such as superficial femoral artery (SFA) occlusion. However, there are concerns about the occurrence of fatigue fractures caused by stress concentrations, neointimal hyperplasia and the like due to the shape structure and the manufacturing method in the conventional stents, and a stent having high strength and high flexibility is required. Therefore, in this research, applicable mesh structures for medical stents based on the design concepts of high strength, high flexibility are interested to solve various problem of conventional stent. According to the shape and dimensions of SFA occlusion therapy stent and indwelling delivery catheter, shape design of the meshed stent are performed using 3-dimensional CAD software Solid Works first. Then analytical examination on storage characteristics and compression characteristics of such mesh structure applied stent models were carried out through finite element analysis software ANSYS Workbench. Meshed stent models with higher strength and higher flexibility with integral molding are investigated analytically. It was found that the storage characteristics and compression characteristics of meshed stent modles are highly dependent on the basic mesh shapes with same surface void ratio. Trade-off relationship between flexibility and storage characteristics is found exited, it is required to provide appropriate curvatures during basic mesh shape design.

  17. A decade of using intraluminal tracheal/bronchial stents in the management of tracheomalacia and/or bronchomalacia: is it better than aortopexy?

    PubMed

    Valerie, Evans P; Durrant, Audrey C; Forte, Vito; Wales, Paul; Chait, Peter; Kim, Peter C W

    2005-06-01

    We compared the efficacy and clinical outcomes of aortopexy versus tracheal stents in the management of tracheomalacia. A retrospective analysis of 25 consecutive patients undergoing aortopexy (n = 11; 8 boys, 3 girls) or tracheal stents (n = 14; 9 boys, 5 girls) between 1993 and 2003 was performed. Both treatment groups, aortopexy versus stents, were comparable in their mean age of diagnosis, timing of intervention, surgical indications ("dying spell" or failed extubation), and previous underlying conditions. The operative time (190 vs 72 minutes) and blood loss (26 vs 0 mL) were significantly greater in aortopexy group (P < .01). There were no perioperative deaths in either group. Interestingly, 4 of 11 patients in the aortopexy group developed pericardial effusion (P < .01). With stents in place for a mean of 15 (range 2-41) months, 3 of 8 patients with stent removal had significant granulation tissue requiring further dilatation. No death was observed in aortopexy group, whereas 1 stent-related death and 1 cardiac arrest requiring median sternotomy occurred during stent removal in 44 and 32 months' follow-up, respectively. Both aortopexy and tracheal stents are effective treatment modalities in the management of tracheomalacia. However, although aortopexy is associated with early perioperative complications, tracheal stents are associated with higher failure rate and more severe stent-related morbidity and mortality.

  18. Numerical analysis of the effect of side holes of a double J stent on flow rate and pattern.

    PubMed

    Kim, Kyung-Wuk; Choi, Young Ho; Lee, Seung Bae; Baba, Yasutaka; Kim, Hyoung-Ho; Suh, Sang-Ho

    2015-01-01

    A double J stent has been used widely these days for patients with a ureteral stenosis or with renal stones and lithotripsy. The stent has multiple side holes in the shaft, which supply detours for urine flow. Even though medical companies produce various forms of double J stents that have different numbers and positions of side holes in the stent, the function of side holes in fluid dynamics has not been studied well. Here, the flow rate and pattern around the side holes of a double J stent were evaluated in curved models of a stented ureter based on the human anatomy and straight models for comparison. The total flow rate was higher in the stent with a greater number of side holes. The inflow and outflow to the stent through the side holes in the curved ureter was more active than in the straight ureter, which means the flow through side holes exists even in the ureter without ureteral stenosis or occlusion and even in the straight ureter. When the diameter of the ureter changed, the in-stent flow rate in the ureter did not change and the extraluminal flow rate was higher in the ureter with a greater diameter.

  19. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation.

    PubMed

    Martin, David M; Murphy, Eoin A; Boyle, Fergal J

    2014-08-01

    In many computational fluid dynamics (CFD) studies of stented vessel haemodynamics, the geometry of the stented vessel is described using non-deformed (NDF) geometrical models. These NDF models neglect complex physical features, such as stent and vessel deformation, which may have a major impact on the haemodynamic environment in stented coronary arteries. In this study, CFD analyses were carried out to simulate pulsatile flow conditions in both NDF and realistically-deformed (RDF) models of three stented coronary arteries. While the NDF models were completely idealised, the RDF models were obtained from nonlinear structural analyses and accounted for both stent and vessel deformation. Following the completion of the CFD analyses, major differences were observed in the time-averaged wall shear stress (TAWSS), time-averaged wall shear stress gradient (TAWSSG) and oscillatory shear index (OSI) distributions predicted on the luminal surface of the artery for the NDF and RDF models. Specifically, the inclusion of stent and vessel deformation in the CFD analyses resulted in a 32%, 30% and 31% increase in the area-weighted mean TAWSS, a 3%, 7% and 16% increase in the area-weighted mean TAWSSG and a 21%, 13% and 21% decrease in the area-weighted mean OSI for Stents A, B and C, respectively. These results suggest that stent and vessel deformation are likely to have a major impact on the haemodynamic environment in stented coronary arteries. In light of this observation, it is recommended that these features are considered in future CFD studies of stented vessel haemodynamics. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. A new approach to improve the local compressive properties of PPDO self-expandable stent.

    PubMed

    Zhao, Fan; Xue, Wen; Wang, Fujun; Yu, Chenglong; Xu, Haiyan; Hao, Yi; Wang, Lu

    2017-04-01

    The radial performance of bioabsorbable polymeric intravascular stents is extremely important in assessing the efficiency of these devices in expanding narrow lumen, reducing stent recoil, and recovering to their original states after suffering from pulsating pressure. However, these stents remain inferior to metallic stents. Several thermal treatment conditions (60°C, 80°C, and 100°C for 1h) were investigated to improve the characteristics of poly(p-dioxanone) (PPDO) self-expandable stents. The local compressive force, stiffness, and viscoelasticity of these stents were also evaluated. Wide-angle X-ray diffraction and different scanning calorimetry measurements were performed to evaluate the recrystalline and thermodynamic changes of molecular chains. The declining conformer entropy of PPDO monofilaments was examined via energy analysis. The untreated stents had compressive modules of 514.80±70.59mN/mm, which was much higher than those of 80°C and 100°C treated stents (332.35±66.08mN/mm and 394.31±64.71mN/mm, respectively). Nevertheless, 100°C annealing stents had less stress relaxation and prior elastic recovery rate of 82.32±3.43mN and 92.55±1.61%, respectively, showing a much better shape stability than untreated stents (139.51±16.67mN and 86.18±3.57%, respectively). These findings present important clinical implications in the stent manufacturing process and warrant further study to develop new bioabsorbable stents with outstanding clinical efficacy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Retrograde pyelography predicts retrograde ureteral stenting failure and reduces unnecessary stenting trials in patients with advanced non-urological malignant ureteral obstruction

    PubMed Central

    Kim, Sung Han; Park, Boram; Joo, Jungnam; Joung, Jae Young; Seo, Ho Kyung; Chung, Jinsoo; Lee, Kang Hyun

    2017-01-01

    Objective To evaluate predictive factors for retrograde ureteral stent failure in patients with non-urological malignant ureteral obstruction. Materials and methods Between 2005 and 2014, medical records of 284 malignant ureteral obstruction patients with 712 retrograde ureteral stent trials including 63 (22.2%) having bilateral malignant ureteral obstruction were retrospectively reviewed. Retrograde ureteral stent failure was defined as the inability to place ureteral stents by cystoscopy, recurrent stent obstruction within one month, or non-relief of azotemia within one week from the prior retrograde ureteral stent. The clinicopathological parameters and first retrograde pyelographic findings were analyzed to investigate the predictive factors for retrograde ureteral stent failure and conversion to percutaneous nephrostomy in multivariate analysis with a statistical significance of p < 0.05. Results Retrograde ureteral stent failure was detected in 14.1% of patients. The mean number of retrograde ureteral stent placements and indwelling duration of the ureteral stents were 2.5 ± 2.6 times and 8.6 ± 4.0 months, respectively. Multivariate analyses identified several specific RGP findings as significant predictive factors for retrograde ureteral stent failure (p < 0.05). The significant retrograde pyelographic findings included grade 4 hydronephrosis (hazard ratio 4.10, 95% confidence interval 1.39–12.09), irreversible ureteral kinking (hazard ratio 2.72, confidence interval 1.03–7.18), presence of bladder invasion (hazard ratio 4.78, confidence interval 1.81–12.63), and multiple lesions of ureteral stricture (hazard ratio 3.46, confidence interval 1.35–8.83) (p < 0.05). Conclusion Retrograde pyelography might prevent unnecessary and ineffective retrograde ureteral stent trials in patients with advanced non-urological malignant ureteral obstruction. PMID:28931043

  2. Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses

    PubMed Central

    Paprottka, Karolin J.; Paprottka, Philipp M.; Reiser, Maximilian F.; Waggershauser, Tobias

    2015-01-01

    PURPOSE Clinical cases of stent-fractures show that corrosion behavior might play a role in these fractures. Implanted in vivo, especially in combination with other implanted foreign materials, these metallic products are exposed to special conditions, which can cause a process of corrosion. Here, we aimed to test the corrosion potential of stents made of different materials in an in vitro setting. METHODS A total of 28 peripheral stents of different materials (nitinol, cobalt-chromium-nickel, tantalum, V4A) and surface treatments (electropolish, mechanical polish, no polish) were tested in vitro. Corrosion was accelerated by applying a constant voltage of 3.5 V and amperage of 1.16 mA in 0.9% NaCl. RESULTS Nitinol stents showed the lowest susceptibility to corrosion and the longest period without damage. The Memotherm II® (BARD Angiomed®) was the only stent that showed neither macroscopic nor microscopic damages. The worst performing material was cobalt-chromium-nickel, which showed corrosion damages about ten times earlier compared to nitinol. Considering the reasons for termination of the test, nitinol stents primarily showed length deficits, while V4A and tantalum stents showed fractures. Cobalt-chromium-nickel stents had multiple fractures or a complete lysis in equal proportions. When placed in direct contact, nitinol stents showed best corrosion resistance, regardless of what material they were combined with. In terms of polishing treatments, electropolished stents performed the best, mechanical-polished stents and those without polishing treatment followed. CONCLUSION The analysis of corrosion behavior may be useful to select the right stent fulfilling the individual needs of the patient within a large number of different stents. PMID:26268301

  3. Feasibility of using bulk metallic glass for self-expandable stent applications.

    PubMed

    Praveen Kumar, Gideon; Jafary-Zadeh, Mehdi; Tavakoli, Rouhollah; Cui, Fangsen

    2017-10-01

    Self-expandable stents are widely used to restore blood flow in a diseased artery segment by keeping the artery open after angioplasty. Despite the prevalent use of conventional crystalline metallic alloys, for example, nitinol, to construct self-expandable stents, new biomaterials such as bulk metallic glasses (BMGs) are being actively pursued to improve stent performance. Here, we conducted a series of analyses including finite element analysis and molecular dynamics simulations to investigate the feasibility of using a prototypical Zr-based BMG for self-expandable stent applications. We model stent crimping of several designs for different percutaneous applications. Our results indicate that BMG-based stents with diamond-shaped crowns suffer from severe localization of plastic deformation and abrupt failure during crimping. As a possible solution, we further illustrate that such abrupt failure could be avoided in BMG-based stents without diamond shape crowns. This work would open a new horizon for a quest toward exploiting superior mechanical and functional properties of metallic glasses to design future stents. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1874-1882, 2017. © 2016 Wiley Periodicals, Inc.

  4. French experience of silicone tracheobronchial stenting in children.

    PubMed

    Fayon, Michael; Donato, Lionel; de Blic, Jacques; Labbé, André; Becmeur, François; Mely, Laurent; Dutau, Hervé

    2005-01-01

    Silicone stents were inserted into the trachea or left main-stem bronchus in 14 children aged 2-69 months (median, 7 months). Indications were as follows: tracheomalacia or airway kinking (7 cases), vascular compression (5 cases), and surgically corrected congenital tracheal stenoses (2 cases). The best results were obtained in tracheomalacia. Overall, 6 cases out of 14 (43%) were considered successful, with a stent placement duration of 3-15 months (median, 7 months). Two cases were considered a technical success, although they were clinical failures. Five cases were considered failures primarily due to stent migration. A retrospective analysis of failures suggests that most of these could have been avoided by the use of larger stents. One patient died of stent obstruction. No wall erosion was observed, and the development of granulation tissue was infrequent. Endoscopic removal of the prostheses was uneventful. The biocompatibility of silicone stents appears to be better than what is reported for metal ones, although the stability of the former is less satisfactory. The present study shows the feasibility of silicone stent placement in infants. These stents should be considered as a possible therapeutic option in certain types of childhood airway disorders, although further studies are required.

  5. Mechanical modeling of self-expandable stent fabricated using braiding technology.

    PubMed

    Kim, Ju Hyun; Kang, Tae Jin; Yu, Woong-Ryeol

    2008-11-14

    The mechanical behavior of a stent is one of the important factors involved in ensuring its opening within arterial conduits. This study aimed to develop a mechanical model for designing self-expandable stents fabricated using braiding technology. For this purpose, a finite element model was constructed by developing a preprocessing program for the three-dimensional geometrical modeling of the braiding structure inside stents, and validated for various stents with different braiding structures. The constituent wires (Nitinol) in the braided stents were assumed to be superelastic material and their mechanical behavior was incorporated into the finite element software through a user material subroutine (VUMAT in ABAQUS) employing a one-dimensional superelastic model. For the verification of the model, several braided stents were manufactured using an automated braiding machine and characterized focusing on their compressive behavior. It was observed that the braided stents showed a hysteresis between their loading and unloading behavior when a compressive load was applied to the braided tube. Through the finite element analysis, it was concluded that the current mechanical model can appropriately predict the mechanical behavior of braided stents including such hysteretic behavior, and that the hysteresis was caused by the slippage between the constituent wires and their superelastic property.

  6. Partially covered self-expandable metal stents versus polyethylene stents for malignant biliary obstruction: A cost-effectiveness analysis

    PubMed Central

    Barkun, Alan N; Adam, Viviane; Martel, Myriam; AlNaamani, Khalid; Moses, Peter L

    2015-01-01

    BACKGROUND/OBJECTIVE: Partially covered self-expandable metal stents (SEMS) and polyethylene stents (PES) are both commonly used in the palliation of malignant biliary obstruction. Although SEMS are significantly more expensive, they are more efficacious than PES. Accordingly, a cost-effectiveness analysis was performed. METHODS: A cost-effectiveness analysis compared the approach of initial placement of PES versus SEMS for the study population. Patients with malignant biliary obstruction underwent an endoscopic retrograde cholangiopancreatography to insert the initial stent. If the insertion failed, a percutaneous transhepatic cholangiogram was performed. If stent occlusion occurred, a PES was inserted at repeat endoscopic retrograde cholangiopancreatography, either in an outpatient setting or after admission to hospital if cholangitis was present. A third-party payer perspective was adopted. Effectiveness was expressed as the likelihood of no occlusion over the one-year adopted time horizon. Probabilities were based on a contemporary randomized clinical trial, and costs were issued from national references. Deterministic and probabilistic sensitivity analyses were performed. RESULTS: A PES-first strategy was both more expensive and less efficacious than an SEMS-first approach. The mean per-patient costs were US$6,701 for initial SEMS and US$20,671 for initial PES, which were associated with effectiveness probabilities of 65.6% and 13.9%, respectively. Sensitivity analyses confirmed the robustness of these results. CONCLUSION: At the time of initial endoscopic drainage for patients with malignant biliary obstruction undergoing palliative stenting, an initial SEMS insertion approach was both more effective and less costly than a PES-first strategy. PMID:26125107

  7. Comparison of the SYNERGY with the PROMUS (XIENCE V) and bare metal and polymer-only Element control stents in porcine coronary arteries.

    PubMed

    Wilson, Gregory J; Huibregtse, Barbara A; Pennington, Douglas E; Dawkins, Keith D

    2012-06-20

    This study evaluated vascular compatibility of the novel platinum chromium alloy Element stent platform delivering abluminal everolimus from a poly-lactide-co-glycolide bioabsorbable polymer (SYNERGY stent), currently undergoing clinical trial, compared with the PROMUS (XIENCE V) and bare metal and polymer-only Element stents. Stents (n=161) were implanted one per coronary artery in 72 swine at a stent-to-artery ratio of 1.1:1. Similar numbers of each device group were explanted at each of 30, 90, 180, and 360 days (except no PROMUS (XIENCE V) stent at 360 days) for pathological analysis. There was no stent thrombosis, myocardial infarction, or strut fractures in any group. Vascular response was similar between the SYNERGY and PROMUS (XIENCE V) stents, with no thrombi and complete endothelialisation on both scanning electron microscopy and histology at 30, 90 and 180 days. There were no significant differences for the morphologic parameters of luminal thrombus, endothelial cell coverage, strut tissue coverage, inflammation, internal elastic lamina (IEL) disruption, external elastic lamina (EEL) disruption and medial smooth muscle cell loss across device groups or between time points, but there was mild but greater (p<0.0001) para-strut fibrin at 30 days for both drug-eluting stents (DES) compared with the bare and polymer-only controls; this difference completely dissipated by 90 days. Inflammation was predominantly minimal to mild for all device types. No morphometric parameters, including intimal thickness, stent profile-based area stenosis, and EEL area were significantly different when comparing the SYNERGY stent with the bare metal Element and polymer-only Element control stents at 90, 180 and 360 days. In this non-injured porcine coronary artery model, the bioabsorbable polymer SYNERGY stent demonstrated vascular compatibility equivalent to the PROMUS (XIENCE V) stent and to the bare metal and polymer-only Element stents.

  8. Heating of cardiovascular stents in intense radiofrequency magnetic fields.

    PubMed

    Foster, K R; Goldberg, R; Bonsignore, C

    1999-01-01

    We consider the heating of a metal stent in an alternating magnetic field from an induction heating furnace. An approximate theoretical analysis is conducted to estimate the magnetic field strength needed to produce substantial temperature increases. Experiments of stent heating in industrial furnaces are reported, which confirm the model. The results show that magnetic fields inside inductance furnaces are capable of significantly heating stents. However, the fields fall off very quickly with distance and in most locations outside the heating coil, field levels are far too small to produce significant heating. The ANSI/IEEE C95.1-1992 limits for human exposure to alternating magnetic fields provide adequate protection against potential excessive heating of the stents.

  9. FFR-guided multivessel stenting reduces urgent revascularization compared with infarct-related artery only stenting in ST-elevation myocardial infarction: A meta-analysis of randomized controlled trials.

    PubMed

    Gupta, Ankur; Bajaj, Navkaranbir S; Arora, Pankaj; Arora, Garima; Qamar, Arman; Bhatt, Deepak L

    2018-02-01

    Randomized controlled trials (RCTs) have shown fractional flow reserve-guided (FFR) multivessel stenting to be superior to infarct-related artery (IRA) only stenting in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. This effect was mainly driven by a reduction in overall repeat revascularization. However, the ability to assess the effect of this strategy on urgent revascularization or reinfarction was underpowered in individual trials. We searched Pubmed, EMBASE, Cochrane CENTRAL, and Web of Science for RCTs of FFR-guided multivessel stenting versus IRA-only stenting in STEMI with multivessel disease. The outcomes of interest were death, reinfarction, urgent, and non-urgent repeat revascularization. Risk ratios (RR) were pooled using the DerSimonian and Laird random-effects model. After review of 786 citations, 2 RCTs were included. The pooled results demonstrated a significant reduction in the composite of death, reinfarction, or revascularization in the FFR-guided multivessel stenting group versus IRA-only stenting group (RR [95%, Confidence Interval]: 0.49 [0.33-0.72], p<0.001). This risk reduction was driven mainly by a reduction in repeat revascularization, both urgent (0.41 [0.24-0.71], p=0.002) and non-urgent revascularization (0.31 [0.19-0.50], p<0.001). Pooled RR for reinfarction was lower in the FFR-guided strategy, but was not statistically significant (0.71[0.39-1.31], p=0.28). This systematic review and meta-analysis suggests that a strategy of FFR-guided multivessel stenting in STEMI patients reduces not only overall repeat revascularization but also urgent revascularization. The effect on reinfarction needs to be evaluated in larger trials. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  10. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature.

    PubMed

    van Halsema, Emo E; Rauws, Erik A J; Fockens, Paul; van Hooft, Jeanin E

    2015-11-21

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher's exact test. A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P < 0.001) and stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P < 0.001). The overall perforation rate was 1.2%. Bleeding was reported in 4.1% of patients, including major bleeding in 0.8%. The median stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO.

  11. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com; Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr; Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payermore » perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.« less

  12. 78 FR 20503 - Energy Conservation Program: Availability of the Interim Technical Support Document for High...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-05

    ... Conservation Program: Availability of the Interim Technical Support Document for High-Intensity Discharge Lamps... high-intensity discharge (HID) lamps energy conservation standards in the Federal Register. This... interim analysis for high- intensity discharge lamps energy conservation standards. The notice provided...

  13. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    PubMed

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P < .01 for all). For stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P < .01 for all). There were no significant differences between stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.

  14. Biliary Endoprosthesis: A Prospective Analysis of Bacterial Colonization and Risk Factors for Sludge Formation

    PubMed Central

    Schneider, Jochen; Hapfelmeier, Alexander; Fremd, Julia; Schenk, Philipp; Obermeier, Andreas; Burgkart, Rainer; Forkl, Stefanie; Feihl, Susanne; Wantia, Nina; Neu, Bruno; Bajbouj, Monther; von Delius, Stefan; Schmid, Roland M.; Algül, Hana; Weber, Andreas

    2014-01-01

    Bacterial colonization of biliary stents is one of the driving forces behind sludge formation which may result in stent occlusion. Major focus of the study was to analyze the spectrum and number of microorganisms in relation to the indwelling time of stents and the risk factors for sludge formation. 343 stents were sonicated to optimize the bacterial release from the biofilm and identified by matrix-associated laser desorption/ionization-time of flight mass spectrometer (MALDI-TOF). 2283 bacteria were analyzed in total. The most prevalent microorganisms were Enterococcus species (spp.) (504;22%), followed by Klebsiella spp. (218;10%) and Candida spp. (188;8%). Colonization of the stents mainly began with aerobic gram-positive bacteria (43/49;88%) and Candida spp. (25/49;51%), whereas stents with an indwelling time>60 days(d) showed an almost equal colonization rate by aerobic gram-negative (176/184;96%) and aerobic gram-positive bacteria (183/184;99%) and a high proportion of anaerobes (127/184;69%). Compared to stents without sludge, more Clostridium spp. [(P = 0.02; Odds Ratio (OR): 2.4; 95% confidence interval (95%CI): (1.1–4.9)]) and Staphylococcus spp. [(P = 0.03; OR (95%CI): 4.3 (1.1–16.5)] were cultured from stents with sludge. Multivariate analysis revealed a significant relationship between the number of microorganisms [P<0.01; OR (95%CI): 1.3(1.1–1.5)], the indwelling time [P<0.01; 1–15 d vs. 20–59 d: OR (95%CI): 5.6(1.4–22), 1–15 d vs. 60–3087 d: OR (95% CI): 9.5(2.5–35.7)], the presence of sideholes [P<0.01; OR (95%CI): 3.5(1.6–7.9)] and the occurrence of sludge. Stent occlusion was found in 70/343(20%) stents. In 35% of cases, stent occlusion resulted in a cholangitis or cholestasis. In conclusion, microbial colonization of the stents changed with the indwelling time. Sludge was associated with an altered spectrum and an increasing number of microorganisms, a long indwelling time and the presence of sideholes. Interestingly, stent occlusion did not necessarily lead to a symptomatic biliary obstruction. PMID:25314593

  15. Endoscopic stenting versus surgical colostomy for the management of malignant colonic obstruction: comparison of hospital costs and clinical outcomes.

    PubMed

    Varadarajulu, Shyam; Roy, Ann; Lopes, Tercio; Drelichman, Ernesto R; Kim, Micheline

    2011-07-01

    Although stent placement is increasingly performed, colostomy still is considered the gold standard for emergent relief of malignant colonic obstruction (MCO). This study aimed to compare hospital costs and clinical outcomes between patients undergoing colostomy and those undergoing stenting for the management of MCO. A retrospective claims analysis of the Medicare Provider Analysis and Review (MedPAR) data set was conducted to identify inpatient hospitalizations for colostomy or stent placement for the treatment of colon cancer (2007-2008). The outcomes evaluated using MedPAR compared the total length of hospital stay (LOS) and the costs associated with both techniques. Because MedPAR is a claims data set that does not provide outcomes at a patient level, a single-institution retrospective case-control study was conducted in which each stent placement patient was matched with two colostomy patients during the same period. Outcome measures (institutional data) were used to compare rates of treatment success, postprocedure LOS, and reinterventions between the two cohorts. The MedPAR data evaluated 778 stent placements and 5,868 colostomy hospitalizations. There were no differences in gender, age distribution, or comorbidity between the two groups. Compared with colostomy, the median LOS (8 vs. 12 days; p<0.0001) and the median cost ($15,071 vs. $24,695; p<0.001) per claim were significantly less for stent placement. Stent placement was more commonly performed at urban versus rural hospitals (84% vs. 16%; p<0.0001), teaching versus nonteaching hospitals (56% vs. 44%; p=0.0058) and larger versus smaller institutions (mean bed capacity, 331 vs. 227; p<0.0001). The institution data included 12 patients who underwent stent placement and 24 who underwent colostomy. Although both methods were technically successful, the median postprocedure LOS (2.17 vs. 10.58 days; p=0.0004) and the rate of readmissions for complications (0% vs. 25%; p=0.01) were significantly lower for stent placement. Although the technical and clinical outcomes for colostomy and stent placement appear comparable, stent placement is less costly and associated with shorter LOS and fewer complications. Dissemination of stent placement beyond large teaching hospitals located in urban areas as a treatment for MCO is important given its implications for patient care and resource use.

  16. The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting.

    PubMed

    Zheng, Dai; Mingyue, Zhu; Wei, Shi; Min, Li; Wanhong, Chen; Qiliang, Dai; Yongjun, Jiang; Xinfeng, Liu

    2018-02-01

    In-stent restenosis (ISR) remains a challenge for vertebrobasilar artery stenting (VBAS). We aimed to investigate the incidence and risk factors of ISR. This was a retrospective study. From July 28, 2005, to July 30, 2015, patients who received VBAS with an angiographic follow-up time of 6 to 12 months after surgery were enrolled. The clinical and angiographic issues were recorded and analyzed. In total, 283 patients with 335 stents were incorporated into the study. Vertebral ostial lesions accounted for 73.4% (246/335) of the lesions. During the follow-up period, 58 patients with 60 stents experienced ISR (>50%). Stepwise logistic regression analysis showed that the degree of residual stenosis, stent diameter, and alcohol consumption were independent predictors of ISR. Our study demonstrated the incidence and risk factors of ISR after VBAS. This retrospective study with the largest cohort to date provided insight into the occurrence of ISR after VBAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Percutaneous Intraductal Radiofrequency Ablation Combined with Biliary Stent Placement for Nonresectable Malignant Biliary Obstruction Improves Stent Patency but not Survival.

    PubMed

    Wang, Jianfeng; Zhao, Lizhen; Zhou, Chuanguo; Gao, Kun; Huang, Qiang; Wei, Baojie; Gao, Jun

    2016-04-01

    Although radiofrequency (RF) ablation has been accepted as a curative treatment modality for solid organ tumors, intraductal RF ablation for malignant biliary obstruction has not been widely described. The aim of this study was to evaluate the feasibility, safety, and efficacy (in terms of stent patency and survival) of intraductal RF ablation combined with biliary stent placement for nonresectable malignant biliary obstruction. A search of the nonresectable malignant extrahepatic biliary obstruction database (179 patients) identified 18 consecutive patients who were treated with biliary intraluminal RF ablation during percutaneous transhepatic cholangiodrainage and inner stent placement (RF ablation group) and 18 patients who underwent inner stent placement without biliary intraluminal RF ablation (control group). The patients were matched for tumor type, location of obstruction, tumor stage, and Child-Pugh class status. Primary endpoints included safety, stent patency time, and survival rates. The secondary endpoint was effectiveness of the technique. The RF ablation and control groups were closely matched in terms of age, diagnosis, presence of metastases, presence of locally advanced tumor, American Society of Anesthesiologists (ASA) grade, and chemotherapy regimen (all P > 0.05). The technical success rate for both groups was 100%. The median time of stent patency in the RF ablation and control groups were 5.8 (2.8-11.5) months and 4.5 (2.4-8.0) months, respectively (Kaplan-Meier analysis: P = 0.03). The median survival times in the RF ablation and control groups were 6.1 (4.8-15.2) months and 5.8 (4.2-16.5) months, with no significant difference according to Kaplan-Meier analysis (P = 0.45). In univariate and multivariate analyses, poorer overall survival was associated with advanced age and presence of metastases (P < 0.05). Intraductal RF ablation combined with biliary stent placement for nonresectable malignant biliary obstruction is safe and feasible and effectively increases stent patency time. However, it does not improve patient survival.

  18. Detailed analysis of periprocedural strokes in patients undergoing intracranial stenting in Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis (SAMMPRIS).

    PubMed

    Fiorella, David; Derdeyn, Colin P; Lynn, Michael J; Barnwell, Stanley L; Hoh, Brian L; Levy, Elad I; Harrigan, Mark R; Klucznik, Richard P; McDougall, Cameron G; Pride, G Lee; Zaidat, Osama O; Lutsep, Helmi L; Waters, Michael F; Hourihane, J Maurice; Alexandrov, Andrei V; Chiu, David; Clark, Joni M; Johnson, Mark D; Torbey, Michel T; Rumboldt, Zoran; Cloft, Harry J; Turan, Tanya N; Lane, Bethany F; Janis, L Scott; Chimowitz, Marc I

    2012-10-01

    Enrollment in the Stenting and Aggressive Medical Management for Preventing Recurrent stroke in Intracranial Stenosis (SAMMPRIS) trial was halted due to the high risk of stroke or death within 30 days of enrollment in the percutaneous transluminal angioplasty and stenting arm relative to the medical arm. This analysis focuses on the patient and procedural factors that may have been associated with periprocedural cerebrovascular events in the trial. Bivariate and multivariate analyses were performed to evaluate whether patient and procedural variables were associated with cerebral ischemic or hemorrhagic events occurring within 30 days of enrollment (termed periprocedural) in the percutaneous transluminal angioplasty and stenting arm. Of 224 patients randomized to percutaneous transluminal angioplasty and stenting, 213 underwent angioplasty alone (n=5) or with stenting (n=208). Of these, 13 had hemorrhagic strokes (7 parenchymal, 6 subarachnoid), 19 had ischemic stroke, and 2 had cerebral infarcts with temporary signs within the periprocedural period. Ischemic events were categorized as perforator occlusions (13), embolic (4), mixed perforator and embolic (2), and delayed stent occlusion (2). Multivariate analyses showed that higher percent stenosis, lower modified Rankin score, and clopidogrel load associated with an activated clotting time above the target range were associated (P ≤ 0.05) with hemorrhagic stroke. Nonsmoking, basilar artery stenosis, diabetes, and older age were associated (P ≤ 0.05) with ischemic events. Periprocedural strokes in SAMMPRIS had multiple causes with the most common being perforator occlusion. Although risk factors for periprocedural strokes could be identified, excluding patients with these features from undergoing percutaneous transluminal angioplasty and stenting to lower the procedural risk would limit percutaneous transluminal angioplasty and stenting to a small subset of patients. Moreover, given the small number of events, the present data should be used for hypothesis generation rather than to guide patient selection in clinical practice. Clinical Trial Registration Information- URL: http://clinicaltrials.gov. Unique Identifier: NCT00576693.

  19. Multivariate analysis applied to the study of spatial distributions found in drug-eluting stent coatings by confocal Raman microscopy.

    PubMed

    Balss, Karin M; Long, Frederick H; Veselov, Vladimir; Orana, Argjenta; Akerman-Revis, Eugena; Papandreou, George; Maryanoff, Cynthia A

    2008-07-01

    Multivariate data analysis was applied to confocal Raman measurements on stents coated with the polymers and drug used in the CYPHER Sirolimus-eluting Coronary Stents. Partial least-squares (PLS) regression was used to establish three independent calibration curves for the coating constituents: sirolimus, poly(n-butyl methacrylate) [PBMA], and poly(ethylene-co-vinyl acetate) [PEVA]. The PLS calibrations were based on average spectra generated from each spatial location profiled. The PLS models were tested on six unknown stent samples to assess accuracy and precision. The wt % difference between PLS predictions and laboratory assay values for sirolimus was less than 1 wt % for the composite of the six unknowns, while the polymer models were estimated to be less than 0.5 wt % difference for the combined samples. The linearity and specificity of the three PLS models were also demonstrated with the three PLS models. In contrast to earlier univariate models, the PLS models achieved mass balance with better accuracy. This analysis was extended to evaluate the spatial distribution of the three constituents. Quantitative bitmap images of drug-eluting stent coatings are presented for the first time to assess the local distribution of components.

  20. Clinical outcome of endoscopic covered metal stenting for resolution of benign biliary stricture: Systematic review and meta-analysis.

    PubMed

    Zheng, Xiao; Wu, Jun; Sun, Bo; Wu, Ye-Chen; Bo, Zhi-Yuan; Wan, Wei; Gao, Dao-Jian; Hu, Bing

    2017-03-01

    Management of benign biliary stricture is challenging. Endoscopic therapy has evolved as the first-line treatment for various benign biliary strictures. However, covered self-expandable metal stents (CSEMS) have not been approved by the United States Food and Drug Administration for the treatment of benign biliary stricture. With this goal, we conducted the present systemic review and meta-analysis to evaluate the efficacy and safety of endoscopic stenting with CSEMS in the treatment of benign biliary stricture. Systematic review and meta-analysis by searching PubMed, MEDLINE and Embase databases. In total, 37 studies (1677 patients) fulfilled the inclusion criteria. Pooled stricture resolutions were achieved in 83% of cases. Median stent dwelling time was 4.4 months, with median endoscopic retrograde cholangiopancreatography sessions of 2.0. Stricture recurrence at 4-year follow up was 11% (95% CI, 8-14%). Pooled complication rate was 23% (95% CI, 20-26%). Placement of CSEMS is effective in the treatment of benign biliary stricture with relatively short stenting duration and low long-term stricture recurrence rate. However, more prospectively randomized studies are required to confirm the results. © 2016 Japan Gastroenterological Endoscopy Society.

  1. Risk factors for and causes and treatment of recurrence of inferior vena cava type of Budd-Chiari syndrome after stenting in China: A retrospective analysis of a large cohort.

    PubMed

    Li, Wen-Dong; Yu, Hui-Ying; Qian, Ai-Min; Rong, Jian-Jie; Zhang, Ye-Qing; Li, Xiao-Qiang

    2017-03-01

    To explore the risk factors for recurrence of inferior vena cava (IVC)-type Budd-Chiari syndrome (BCS) after stenting and evaluate the feasibility and primary outcomes of endovascular therapies for recurrent BCS. A retrospective analysis of 219 patients was performed to identify risk factors for recurrence. The images of the recurrent patients during follow-up duration and interventional surgery were also reviewed to find the possible reasons of recurrence. The outcome of endovascular therapies for recurrent BCS was evaluated by Kaplan-Meier analysis. Among the 219 patients, 172 patients with primary IVC-type BCS underwent stenting and 28 patients experienced recurrence. Multivariate analysis identified age, Child-Pugh score, MELD and total bilirubin as independent recurrent indicators. Possible causes of recurrence include thrombosis in the stent, re-obstruction in or above the stent, and stent-related hepatic vein obstruction. Twenty-five patients with recurrent BCS underwent endovascular therapies with a few complications and achieved a high level of short- and mid-term patency. Age, total bilirubin and severity of liver function are the main risk factors for BCS recurrence. These risks might contribute to thrombosis or subsequent fibrous obstruction. Endovascular therapies are effective and safe management options that yield positive outcomes for recurrent BCS. • Risk factors for recurrent Budd-Chiari syndrome were identified by multivariate analysis. • Causes of recurrent Budd-Chiari syndrome were investigated by assessing radiological images. • There is a correlation between risk factors and causes of recurrence. • Endovascular therapies for recurrent Budd-Chiari syndrome are effective and safe.

  2. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    PubMed

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  3. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology

    PubMed Central

    Dohatcu, A.; Ionita, C. N.; Paciorek, A.; Bednarek, D. R.; Hoffmann, K. R.; Rudin, S.

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification. PMID:18958295

  4. After urgent drainage of an obstructed kidney by internal ureteric stenting; is ureteroscopic stone extraction always needed?

    PubMed Central

    Taha, Diaa-Eldin; Elshal, Ahmed M.; Zahran, Mohamed H.; Harraz, Ahmed M.; El-Nahas, Ahmed R.; Shokeir, Ahmed A.

    2015-01-01

    Objectives To assess the probability of spontaneous stone passage and its predictors after drainage of obstructed kidney by JJ stent, as insertion of an internal ureteric stent is often used for renal drainage in cases of calcular ureteric obstruction. Patients and methods Between January 2011 and June 2013, patients for whom emergent drainage by ureteric stents were identified. The patients’ demographics, presentation, and stone characteristics were reviewed. The primary endpoint for this study was stone-free status at the time of stent removal, where all patients underwent non-contrast spiral computed tomography (NCCT) before stent removal. Ureteroscopic stone extraction was performed for CT detectable ureteric stones at the time of stent removal. Potential factors affecting the need for ureteroscopic stone extraction at the time of stent removal were assessed using univariate and multivariate statistical analyses. Results Emergent ureteric stents were undertaken in 196 patients (112 males, 84 females) with a mean (SD) age of 53.7 (16.2) years, for renal obstruction drainage. At the time of stent removal, 83 patients (42.3%) were stone free; with the remaining 113 patients (57.7%) undergoing ureteroscopic stone extraction. On multivariate analysis, stone width [odds ratio (OR) 15.849, 95% confidence interval (CI) 2.83; P = 0.002) and radio-opaque stones (OR 12.035, 95% CI 4.65; P < 0.001) were independent predictors of the need for ureteroscopic stone extraction at the time of stent removal. Conclusion Spontaneous ureteric stone passage is possible after emergent drainage of an obstructed kidney by ureteric stenting. Stone opacity, larger stone width, and positive preoperative urine culture are associated with a greater probability of requiring ureteroscopic stone extraction after emergent drainage by ureteric stenting. PMID:26609444

  5. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    PubMed

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p < 0.0001). The Strecker Tantalum stent (85.9 ± 1.95 cm/sec, p < 0.0001) generated the highest BV values. CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images.

    PubMed

    Gabriele, Alex; Marco, Valeria; Gatto, Laura; Paoletti, Giulia; Di Vito, Luca; Castriota, Fausto; Romagnoli, Enrico; Ricciardi, Andrea; Prati, Francesco

    2014-10-01

    The optical coherence tomography (OCT) evaluation of the stent anatomy requires the inspection of sequential cross section (CS). However stent coils cannot be appreciated in the conventional format as the OCT CS simply display stent struts, that are poorly representative of the stent architecture. The aim of the present study was to validate a new software (Carpet View), which unfolds the stented segment, reconstructing it as an open structure and displaying the stent meshwork. 21 patients were studied with frequency domain OCT after the deployment of different stents: seven bio-absorbable scaffolds (Dream), seven bare metal stent (Vision/Multilink8), seven drug eluting stent (Cre8). Conventional CS reconstructions were post-processed with the Carpet View software and analyzed by the same reader twice (intra-observer variability) and by two different readers (inter-observer variability). A small average difference in the number of all struts was obtained with the two methods (conventional vs carpet view reconstruction). Using the carpet view, high intra-observer and inter-observer correlations were found for the number of struts obtained in each coil. The Pearson correlation values were 0.98 (p = 0.0001) and 0.96 (p = 0.0001) respectively. The same number of coils was found when analyses were repeated by the same reader or by a different reader whilst mild differences in the count of stent junctions were reported. The Carpet View can be used to address the stent geometry with high reproducibility. This approach enables the matching of the same stent portion during serial time points and promises to improve the stent assessment.

  7. Percutaneous unilateral biliary metallic stent placement in patients with malignant obstruction of the biliary hila and contralateral portal vein steno-occlusion.

    PubMed

    Son, Rak Chae; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi-Young

    2015-01-01

    To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents.

  8. Percutaneous Unilateral Biliary Metallic Stent Placement in Patients with Malignant Obstruction of the Biliary Hila and Contralateral Portal Vein Steno-Occlusion

    PubMed Central

    Son, Rak Chae; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi-Young

    2015-01-01

    Objective To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Materials and Methods Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. Results A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Conclusion Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents. PMID:25995688

  9. Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms.

    PubMed

    Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua

    2018-01-01

    To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.

  10. Prospective analysis of a complete retrograde ureteroscopic technique with holmium laser stent cutting for management of encrusted ureteral stents.

    PubMed

    Thomas, Alexandre; Cloutier, Jonathan; Villa, Luca; Letendre, Julien; Ploumidis, Achilles; Traxer, Olivier

    2017-03-14

    To propose and evaluate a new endoscopic technique using only a retrograde ureteroscopic approach for the removal of heavily encrusted ureteral stents. Data from 51 consecutive patients with encrusted and retained ureteral stents were prospectively collected. Description of the successive steps of surgery is detailed. The Holmium-YAG laser properties offer the opportunity for fragmentation of stent-attached encrustation and the ability to cut the stent itself. Reducing the length of the stent is critical to creating space in the ureter and to allow free access for ureteroscopes or ureteral access sheath placement. The primary outcome of this study was the feasibility and the safety of this retrograde intra-renal approach. Some factors of encrustation and outcomes are also discussed in comparison with lithotripsy, percutaneous, laparoscopic, open surgery or a combination of these techniques. The removal of the encrusted stent was possible with only this retrograde technique in 98% of patients. The transection of the encrusted stent with the Holmium-YAG laser was useful in 71% of the patients. Mean operative time was 110 minutes and mean hospital stay was 2.33 days. Postoperative complications were mainly non-obstructive pyelonephritis (10%). The most significant predictor of this life threatened complication was the presence of struvite stones with the encrusted stent (p=0,018). Contrariwise, operative time, BMI, gender and encrustation rate were not associated with postoperative pyelonephritis. Cystine stone disease or pregnancy both led to faster stent encrustation. Retrograde ureteroscopic surgery is efficient and safe for removing retained stents and associated stone burdens. The Holmium-YAG laser is essential to perform the encrustation removal and sectioning of the stent.

  11. Durability of Silicone Airway Stents in the Management of Benign Central Airway Obstruction.

    PubMed

    Karush, Justin M; Seder, Christopher W; Raman, Anish; Chmielewski, Gary W; Liptay, Michael J; Warren, William H; Arndt, Andrew T

    2017-10-01

    The literature is devoid of a comprehensive analysis of silicone airway stenting for benign central airway obstruction (BCAO). With the largest series in the literature to date, we aim to demonstrate the safety profile, pattern of re-intervention, and duration of silicone airway stents. An institutional database was used to identify patients with BCAO who underwent rigid bronchoscopy with dilation and silicone stent placement between 2002 and 2015 at Rush University Medical Center. During the study period, 243 stents were utilized in 63 patients with BCAO. Pure tracheal stenosis was encountered in 71% (45/63), pure tracheomalacia in 11% (7/63), and a hybrid of both in 17% (11/63). Median freedom from re-intervention was 104 (IQR 167) days. Most common indications for re-intervention include mucus accumulation (60%; 131/220), migration (28%; 62/220), and intubation (8%; 18/220). The most common diameters of stent placed were 12 mm (94/220) and 14 mm (96/220). The most common lengths utilized were 30 mm (60/220) and 40 mm (77/220). Duration was not effected by stent size when placed for discrete stenosis. However, 14 mm stents outperformed 12 mm when tracheomalacia was present (157 vs. 37 days; p = 0.005). Patients with a hybrid stenosis fared better when longer stents were used (60 mm stents outlasted 40 mm stents 173 vs. 56 days; p = 0.05). Rigid bronchoscopy with silicone airway stenting is a safe and effective option for the management of benign central airway obstruction. Our results highlight several strategies to improve stent duration.

  12. Impact of the Distance from the Stent Edge to the Residual Plaque on Edge Restenosis following Everolimus-Eluting Stent Implantation

    PubMed Central

    Myojo, Masahiro; Sawaki, Daigo; Iwata, Hiroshi; Kiyosue, Arihiro; Higashikuni, Yasutomi; Tanaka, Tomofumi; Fujita, Daishi; Ando, Jiro; Fujita, Hideo; Hirata, Yasunobu; Komuro, Issei

    2015-01-01

    Objectives This study aimed to assess the relation between stent edge restenosis (SER) and the distance from the stent edge to the residual plaque using quantitative intravascular ultrasound. Background Although percutaneous coronary intervention with drug-eluting stents has improved SER rates, determining an appropriate stent edge landing zone can be challenging in cases of diffuse plaque lesions. It is known that edge vascular response can occur within 2 mm from the edge of a bare metal stent, but the distance to the adjacent plaque has not been evaluated for drug-eluting stents. Methods A total of 97 proximal residual plaque lesions (plaque burden [PB] >40%) treated with everolimus-eluting stents were retrospectively evaluated to determine the distance from the stent edge to the residual plaque. Results The SER group had significantly higher PB (59.1 ± 6.1% vs. 51.9 ± 9.1% for non-SER; P = 0.04). Higher PB was associated with SER, with the cutoff value of 54.74% determined using receiver operating characteristic (ROC) curve analysis. At this cutoff value of PB, the distance from the stent edge to the lesion was significantly associated with SER (odds ratio = 2.05, P = 0.035). The corresponding area under the ROC curve was 0.725, and the cutoff distance value for predicting SER was 1.0 mm. Conclusion An interval less than 1 mm from the proximal stent edge to the nearest point with the determined PB cutoff value of 54.74% was significantly associated with SER in patients with residual plaque lesions. PMID:25775115

  13. Causes of failure with Szabo technique - an analysis of nine cases.

    PubMed

    Jain, Rajendra Kumar; Padmanabhan, T N C; Chitnis, Nishad

    2013-01-01

    The objective of this case series is to identify and define causes of failure of Szabo technique in rapid-exchange monorail system for ostial lesions. From March 2009 to March 2011, 42 patients with an ostial lesion were treated percutaneously at our institution using Szabo technique in a monorail stent system. All patients received unfractionated heparin during intervention. Loading dose of clopidogrel, followed by clopidogrel and aspirin was administered. In 57% of patients, drug-eluting stents were used and in 42.8% patients bare metal stents. The stent was advanced over both wires, the target wire and the anchor wire. The anchor wire, which was passed through the proximal trailing strut of the stent helps to achieve precise stenting. The procedure was considered to be successful if stent was placed precisely covering the lesion and without stent loss or anchor wire prolapsing. Of the total 42 patients, the procedure was successful in 33, while failed in 9. Majority of failures were due to wire entanglement, which was fixed successfully in 3 cases by removing and reinserting the anchor wire. Out of other three failures, in one stent dislodgment occurred, stent could not cross the lesion in one and in another anchor wire got looped and prolapsed into target vessel. This case series shows that the Szabo technique, in spite of some difficulties like wire entanglement, stent dislodgement and resistance during stent advancement, is a simple and feasible method for treating variety of ostial lesions precisely compared to conventional angioplasty. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  14. Causes of failure with Szabo technique – An analysis of nine cases

    PubMed Central

    Jain, Rajendra Kumar; Padmanabhan, T.N.C.; Chitnis, Nishad

    2013-01-01

    Objective The objective of this case series is to identify and define causes of failure of Szabo technique in rapid-exchange monorail system for ostial lesions. Methods and results From March 2009 to March 2011, 42 patients with an ostial lesion were treated percutaneously at our institution using Szabo technique in a monorail stent system. All patients received unfractionated heparin during intervention. Loading dose of clopidogrel, followed by clopidogrel and aspirin was administered. In 57% of patients, drug-eluting stents were used and in 42.8% patients bare metal stents. The stent was advanced over both wires, the target wire and the anchor wire. The anchor wire, which was passed through the proximal trailing strut of the stent helps to achieve precise stenting. The procedure was considered to be successful if stent was placed precisely covering the lesion and without stent loss or anchor wire prolapsing. Of the total 42 patients, the procedure was successful in 33, while failed in 9. Majority of failures were due to wire entanglement, which was fixed successfully in 3 cases by removing and reinserting the anchor wire. Out of other three failures, in one stent dislodgment occurred, stent could not cross the lesion in one and in another anchor wire got looped and prolapsed into target vessel. Conclusion This case series shows that the Szabo technique, in spite of some difficulties like wire entanglement, stent dislodgement and resistance during stent advancement, is a simple and feasible method for treating variety of ostial lesions precisely compared to conventional angioplasty. PMID:23809379

  15. Efficacy of a Dexamethasone-Eluting Nitinol Stent on the Inhibition of Pseudointimal Hyperplasia in a Transjugular Intrahepatic Portosystemic Shunt: An Experimental Study in a Swine Model

    PubMed Central

    Seo, Tae-Seok; Park, Young-Koo; Song, Ho-Young; Park, Sang Joon; Yuk, Sun-Hong

    2005-01-01

    Objective We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Materials and Methods Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. Results One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. Conclusion The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension. PMID:16374082

  16. Impact of the distance from the stent edge to the residual plaque on edge restenosis following everolimus-eluting stent implantation.

    PubMed

    Takahashi, Masao; Miyazaki, Susumu; Myojo, Masahiro; Sawaki, Daigo; Iwata, Hiroshi; Kiyosue, Arihiro; Higashikuni, Yasutomi; Tanaka, Tomofumi; Fujita, Daishi; Ando, Jiro; Fujita, Hideo; Hirata, Yasunobu; Komuro, Issei

    2015-01-01

    This study aimed to assess the relation between stent edge restenosis (SER) and the distance from the stent edge to the residual plaque using quantitative intravascular ultrasound. Although percutaneous coronary intervention with drug-eluting stents has improved SER rates, determining an appropriate stent edge landing zone can be challenging in cases of diffuse plaque lesions. It is known that edge vascular response can occur within 2 mm from the edge of a bare metal stent, but the distance to the adjacent plaque has not been evaluated for drug-eluting stents. A total of 97 proximal residual plaque lesions (plaque burden [PB] >40%) treated with everolimus-eluting stents were retrospectively evaluated to determine the distance from the stent edge to the residual plaque. The SER group had significantly higher PB (59.1 ± 6.1% vs. 51.9 ± 9.1% for non-SER; P = 0.04). Higher PB was associated with SER, with the cutoff value of 54.74% determined using receiver operating characteristic (ROC) curve analysis. At this cutoff value of PB, the distance from the stent edge to the lesion was significantly associated with SER (odds ratio = 2.05, P = 0.035). The corresponding area under the ROC curve was 0.725, and the cutoff distance value for predicting SER was 1.0 mm. An interval less than 1 mm from the proximal stent edge to the nearest point with the determined PB cutoff value of 54.74% was significantly associated with SER in patients with residual plaque lesions.

  17. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    PubMed Central

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and fistulae is promising. PMID:25685270

  18. Prevalence, Features, and Prognostic Importance of Edge Dissection After Drug-Eluting Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy.

    PubMed

    Kobayashi, Nobuaki; Mintz, Gary S; Witzenbichler, Bernhard; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko

    2016-07-01

    Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patients undergoing drug-eluting stent implantation. In this prospective substudy, 2062 patients (2433 lesions) were evaluated with intravascular ultrasound to characterize the morphological features and clinical outcomes of stent edge dissection after percutaneous coronary intervention. The prevalence of post-percutaneous coronary intervention stent edge dissection was 6.6% per lesion (161 of 2433). Calcified plaque at the proximal stent edge (relative risk [RR]=1.72; P=0.04) and proximal stent edge expansion (RR=1.18; P=0.004) were predictors for proximal dissection; attenuated plaque at the distal stent edge (RR=3.52; P=0.004), distal reference plaque burden (RR=1.56; P<0.0001), and distal edge stent expansion (RR=1.11; P=0.02) were predictors for distal dissection. At 1-year follow-up, target lesion revascularization was more common in lesions with versus without dissection (5.2% versus 2.7%; P=0.04). Multivariable analysis indicated that residual dissection was associated with target lesion revascularization at 1-year follow-up (RR=2.67; P=0.02). Among lesions with dissection, smaller effective lumen area increased the risk of target lesion revascularization at 1-year follow-up (cutoff value of 5.1 mm(2); P=0.05). Greater stent expansion and the presence of large, calcified, and/or attenuated plaques were independent predictors of stent edge dissection. Residual stent edge dissection, especially with a smaller effective lumen area, was associated with target lesion revascularization during 1-year follow-up after drug-eluting stent implantation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2016 American Heart Association, Inc.

  19. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    PubMed

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and fistulae is promising.

  20. Temporary placement of metallic stent could lead to long-term benefits for benign tracheobronchial stenosis.

    PubMed

    Zhou, Guo-Wu; Huang, Hai-Dong; Sun, Qin-Ying; Xiong, Ye; Li, Qiang; Dong, Yu-Chao; Zhang, Wei

    2015-12-01

    The permanent placement of metallic stent for benign tracheobronchial stenosis (BTS) was controversial. This study was conducted to evaluate the long-term outcomes of temporary placement of metallic stent for BTS. The BTS patients who received temporary placement of retrievable self-expanded metallic stents were included between 2008 and 2011. Pre-stenting and follow-up respiratory status was analyzed. And symptom recurrence-free survival (SRFS) was assessed. A total of 49 stents were successfully temporarily placed in 40 consecutive BTS patients whose etiologies included endobronchial tuberculosis (EBTB) (n=22), post-tracheostomy stenosis (n=10), post-intubation stenosis (n=6) and post radiotherapy stricture (n=2). All stents were removed integrally after a median 18 days' stenting period, without major complications. During the median 27 months follow-up period after stent removal, a total of 22 patients were free of recurrence. And the overall 3-year SRFS rate was 52.0%. According to the etiology, the 3-year SRFS rates were 59.1% and 42.9% in the patients with EBTB and non-EBTB, respectively. Compared with pre-stenting, the follow-up internal diameter of stricture, Hugh-Jones scale, 6-minute walk test (6MWT) and percentage of forced expiratory volume in one second (FEV1%) were significantly improved. Multivariate analysis suggested that granulation tissue growth and tracheobronchial malacia might be independent factors of poor prognosis. Temporary placement of retrievable metallic stent may be an alternative treatment for BTS patients.

  1. Initial study of sediment antagonism and characteristics of silver nanoparticle-coated biliary stents in an experimental animal model.

    PubMed

    Tian, Yigeng; Xia, Mingfeng; Zhang, Shuai; Fu, Zhen; Wen, Qingbin; Liu, Feng; Xu, Zongzhen; Li, Tao; Tian, Hu

    2016-01-01

    Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs) and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice. AgNP-coated Teflon biliary stents were prepared by chemical oxidation-reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD); animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA), and the composition of sediment was assayed by Fourier-transform infrared (FTIR) spectroscopy. Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5-6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR spectroscopy identified stent sediment components including bilirubin, cholesterol, bile acid, protein, calcium, and other substances. AgNP-coated biliary stents resisted sediment accumulation in this canine model of obstructive jaundice caused by ligation of the CBD.

  2. Initial study of sediment antagonism and characteristics of silver nanoparticle-coated biliary stents in an experimental animal model

    PubMed Central

    Tian, Yigeng; Xia, Mingfeng; Zhang, Shuai; Fu, Zhen; Wen, Qingbin; Liu, Feng; Xu, Zongzhen; Li, Tao; Tian, Hu

    2016-01-01

    Objective Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs) and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice. Methods AgNP-coated Teflon biliary stents were prepared by chemical oxidation–reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD); animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA), and the composition of sediment was assayed by Fourier-transform infrared (FTIR) spectroscopy. Results Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5–6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR spectroscopy identified stent sediment components including bilirubin, cholesterol, bile acid, protein, calcium, and other substances. Conclusion AgNP-coated biliary stents resisted sediment accumulation in this canine model of obstructive jaundice caused by ligation of the CBD. PMID:27217749

  3. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo.

    PubMed

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Van Alstine, William; Binkert, Christoph A; Klausen, Kasper

    2017-01-01

    This study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo. A diamond-shaped stent-base was cut from a sequential biaxially strained poly(L-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively. In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks. A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  4. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Løvdal, Alexandra Liv Vest, E-mail: alvlo@nanotech.dtu.dk; Calve, Sarah; Yang, Shuo

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed anmore » elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.« less

  5. Biofilms and Physical Deposits on Nasolacrimal Silastic Stents Following Dacryocystorhinostomy: Is There a Difference Between Ocular and Nasal Segments?

    PubMed

    Ali, Mohammad Javed; Baig, Farhana; Lakshman, Mekala; Naik, Milind N

    2015-01-01

    The aims of this study were to examine the presence of biofilms and physical deposits on ocular and nasal segments of silastic nasolacrimal duct stents inserted after dacryocystorhinostomy and to document any differences. A prospective interventional study was performed on a series of patients undergoing dacryocystorhinostomy with Crawford stent insertion. All the patient samples were retrieved 4 weeks after an endoscopic dacryocystorhinostomy. None of the patients had any evidence of postoperative infection. The ocular and nasal segments were separated during retrieval. After removal, the stent segments were subjected to biofilm and physical deposit analysis using standard protocols of scanning electron microscopy. These stent segments were compared against sterile stents which acted as controls. A total of 11 stents were studied. Nine were consecutive patient samples and 2 were sterile stents. The ocular and nasal segments of all the stents demonstrated evidence of biofilm formation and physical deposits. However, the deposits and biofilms were thicker and extensive in the ocular segment, although more focal in nature. In contrast, the nasal segments showed thinner biofilms and sparser deposits but were more diffuse in nature. The presence of different-sized organisms within the exopolysaccharide matrix and in between the deposits suggests the existence of polymicrobial communities. This is the first study to report the differences between ocular and nasal segments of lacrimal stents. These differences could propel further studies on stent biomechanics and their interactions with ocular and nasal tissues, following a dacryocystorhinostomy.

  6. Drug eluting balloons for de novo coronary lesions – a systematic review and meta-analysis

    PubMed Central

    2013-01-01

    Background The role of drug-eluting balloons (DEB) is unclear. Increasing evidence has shown a benefit for the treatment of in-stent restenosis. Its effect on de novo coronary lesions is more controversial. Several smaller randomized trials found conflicting results. Methods This is a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the effect of local Paclitaxel delivery/drug eluting balloons (DEB) (+/− bare metal stent) compared to current standard therapy (stenting) to treat de novo coronary lesions. Data sources for RCT were identified through a literature search from 2005 through 28 December 2012. The main endpoints of interest were target lesion revascularization (TLR), major adverse cardiac events (MACE), binary in-segment restenosis, stent thrombosis (ST), myocardial infarction (MI), late lumen loss (LLL) and mortality. A random effects model was used to calculate the pooled relative risks (RR) with 95% confidence intervals. Results Eight studies (11 subgroups) and a total of 1,706 patients were included in this analysis. Follow-up duration ranged from 6 to 12 months. Overall, DEB showed similar results to the comparator treatment. The relative risk (RR) for MACE was 0.95 (0.64 to 1.39); P = 0.776, for mortality it was 0.79 (0.30 to 2.11), P = 0.644, for stent thrombosis it was 1.45 (0.42 to 5.01), P = 0.560, for MI it was 1.26 (0.49 to 3.21), P = 0.629, for TLR it was 1.09 (0.71 to 1.68); P = 0.700 and for binary in-stent restenosis it was 0.96 (0.48 to 1.93), P = 0.918. Compared to bare metal stents (BMS), DEB showed a lower LLL (− 0.26 mm (−0.51 to 0.01)) and a trend towards a lower MACE risk (RR 0.66 (0.43 to 1.02)). Conclusion Overall, drug-eluting balloons (+/− bare metal stent) are not superior to current standard therapies (BMS or drug eluting stent (DES)) in treating de novo coronary lesions. However, the performance of DEB seems to lie in between DES and BMS with a trend towards superiority over BMS alone. Therefore, DEB may be considered in patients with contraindications for DES. The heterogeneity between the included studies is a limitation of this meta-analysis; different drug-eluting balloons have been used. PMID:23657123

  7. Endoscopic Stenting as Bridge to Surgery versus Emergency Resection for Left-Sided Malignant Colorectal Obstruction: An Updated Meta-Analysis

    PubMed Central

    Ceresoli, Marco; Fugazzola, Paola; Ansaloni, Luca

    2017-01-01

    Introduction Emergency resection represents the traditional treatment for left-sided malignant obstruction. However, the placement of self-expanding metallic stents and delayed surgery has been proposed as an alternative approach. The aim of the current meta-analysis was to review the available evidence, with particular interest for the short-term outcomes, including a recent multicentre RCT. Methods We considered randomized controlled trials comparing stenting as a bridge to surgery and emergency surgery for the management of left-sided malignant large bowel obstruction, performing a systematic review in MEDLINE, PubMed database, and the Cochrane libraries. Results We initially identified a total of 2543 studies. After the elimination of duplicates and the screening of titles and abstracts, seven studies, for a total of 448 patients, were considered. The current meta-analysis revealed no difference in the mortality rate between the stent group and the emergency surgery group; the postoperative complication rate (37.84% versus 54.87%, P = 0.02), the stoma rate (28.8% versus 46.02%, P < 0.0001), and the incidence of wound infection (8.11% versus 15.49%, P = 0.01) were reduced after stent as a bridge to surgery. Conclusion Colonic stenting as a bridge to surgery appears to be a safe approach to malignant large bowel obstruction. Possible advantages of this treatment can be identified in a reduced incidence of postoperative complications and a lower stoma rate. Further RCTs considering long-term outcomes and cost-effectiveness analysis are needed. PMID:28761765

  8. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    PubMed

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  9. Evolution of the degradation mechanism of pure zinc stent in the one-year study of rabbit abdominal aorta model.

    PubMed

    Yang, Hongtao; Wang, Cong; Liu, Chaoqiang; Chen, Houwen; Wu, Yifan; Han, Jintao; Jia, Zichang; Lin, Wenjiao; Zhang, Deyuan; Li, Wenting; Yuan, Wei; Guo, Hui; Li, Huafang; Yang, Guangxin; Kong, Deling; Zhu, Donghui; Takashima, Kazuki; Ruan, Liqun; Nie, Jianfeng; Li, Xuan; Zheng, Yufeng

    2017-11-01

    In the present study, pure zinc stents were implanted into the abdominal aorta of rabbits for 12 months. Multiscale analysis including micro-CT, scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM) and histological stainings was performed to reveal the fundamental degradation mechanism of the pure zinc stent and its biocompatibility. The pure zinc stent was able to maintain mechanical integrity for 6 months and degraded 41.75 ± 29.72% of stent volume after 12 months implantation. No severe inflammation, platelet aggregation, thrombosis formation or obvious intimal hyperplasia was observed at all time points after implantation. The degradation of the zinc stent played a beneficial role in the artery remodeling and healing process. The evolution of the degradation mechanism of pure zinc stents with time was revealed as follows: Before endothelialization, dynamic blood flow dominated the degradation of pure zinc stent, creating a uniform corrosion mode; After endothelialization, the degradation of pure zinc stent depended on the diffusion of water molecules, hydrophilic solutes and ions which led to localized corrosion. Zinc phosphate generated in blood flow transformed into zinc oxide and small amounts of calcium phosphate during the conversion of degradation microenvironment. The favorable physiological degradation behavior makes zinc a promising candidate for future stent applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Use of ureteral stent in extracorporeal shock wave lithotripsy for upper urinary calculi: a systematic review and meta-analysis.

    PubMed

    Shen, Pengfei; Jiang, Min; Yang, Jie; Li, Xiong; Li, Yutao; Wei, Wuran; Dai, Yi; Zeng, Hao; Wang, Jia

    2011-10-01

    This systematic review was performed to assess the necessity and complications of stenting before extracorporeal shock wave lithotripsy in the management of upper urinary stones. A systematic research of PubMed®, EMBASE® and the Cochrane Library was performed to identify all randomized controlled trials. The comparisons were about the outcomes and complications of extracorporeal shock wave lithotripsy in the management of upper urinary stones with or without Double-J stenting before extracorporeal shock wave lithotripsy, including stone-free rate, Steinstrasse, lower urinary tract symptoms, hematuria, fever, urinary tract infection, pain and analgesia, auxiliary treatment, and nausea and vomiting. We used the Cochrane Collaboration's Review Manager (RevMan) 5.0.2 software for statistical analysis. Eight randomized controlled trials were included in analysis that reported 876 patients in total, divided into the stented group of 453 and the stentless group of 423. All studies recorded the stone-free rate and the results of the meta-analysis showed no difference between the groups (RR 0.97, 95% CI 0.91-1.03, p = 0.27). The total incidence of Steinstrasse in the stented group was similar to that of the stentless group with the exception of 1 study. However, the incidence of lower urinary tract symptoms was significantly higher in the stented group than in the stentless group (RR 4.10, 95% CI 2.21-7.61, p <0.00001). Significant differences could not be found in hematuria, fever, urinary tract infection, pain and analgesia, auxiliary treatment, or nausea and vomiting between the groups. The systematic review suggested significant advantages of stenting before extracorporeal shock wave lithotripsy compared to in situ extracorporeal shock wave lithotripsy in terms of Steinstrasse. However, stenting did not benefit stone-free rate and auxiliary treatment after extracorporeal shock wave lithotripsy, and it induced more lower urinary tract symptoms. More high quality, randomized controlled trials are needed to address this issue. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. CT Evaluation of Small-Diameter Coronary Artery Stents: Effect of an Integrated Circuit Detector with Iterative Reconstruction.

    PubMed

    Geyer, Lucas L; Glenn, G Russell; De Cecco, Carlo Nicola; Van Horn, Mark; Canstein, Christian; Silverman, Justin R; Krazinski, Aleksander W; Kemper, Jenny M; Bucher, Andreas; Ebersberger, Ullrich; Costello, Philip; Bamberg, Fabian; Schoepf, U Joseph

    2015-09-01

    To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.

  12. Impact of biliary stent-related events in patients diagnosed with advanced pancreatobiliary tumours receiving palliative chemotherapy.

    PubMed

    Lamarca, Angela; Rigby, Christina; McNamara, Mairéad G; Hubner, Richard A; Valle, Juan W

    2016-07-14

    To determine the impact (morbidity/mortality) of biliary stent-related events (SRE) (cholangitis or stent obstruction) in chemotherapy-treated pancreatico-biliary patients. All consecutive patients with advanced pancreatobiliary cancer and a biliary stent in-situ prior to starting palliative chemotherapy were identified retrospectively from local electronic case-note records (Jan 13 to Jan 15). The primary end-point was SRE rate and the time-to-SRE (defined as time from first stenting before chemotherapy to date of SRE). Progression-free survival and overall survival were measured from the time of starting chemotherapy. Kaplan-Meier, Cox and Fine-Gray regression (univariate and multivariable) analyses were employed, as appropriate. For the analysis of time-to-SRE, death was considered as a competing event. Ninety-six out of 693 screened patients were eligible; 89% had a metal stent (the remainder were plastic). The median time of follow-up was 9.6 mo (range 2.2 to 26.4). Forty-one patients (43%) developed a SRE during follow-up [cholangitis (39%), stent obstruction (29%), both (32%)]. There were no significant differences in baseline characteristics between the SRE group and no-SRE groups. Recorded SRE-consequences were: none (37%), chemotherapy delay (24%), discontinuation (17%) and death (22%). The median time-to-SRE was 4.4 mo (95%CI: 3.6-5.5). Patients with severe comorbidities (P < 0.001) and patients with ≥ 2 baseline stents/biliary procedures [HR = 2.3 (95%CI: 1.2-4.44), P = 0.010] had a shorter time-to-SRE on multivariable analysis. Stage was an independent prognostic factor for overall survival (P = 0.029) in the multivariable analysis adjusted for primary tumour site, performance status and development of SRE (SRE group vs no-SRE group). SREs are common and impact on patient's morbidity. Our results highlight the need for prospective studies exploring the role of prophylactic strategies to prevent/delay SREs.

  13. Impact of biliary stent-related events in patients diagnosed with advanced pancreatobiliary tumours receiving palliative chemotherapy

    PubMed Central

    Lamarca, Angela; Rigby, Christina; McNamara, Mairéad G; Hubner, Richard A; Valle, Juan W

    2016-01-01

    AIM: To determine the impact (morbidity/mortality) of biliary stent-related events (SRE) (cholangitis or stent obstruction) in chemotherapy-treated pancreatico-biliary patients. METHODS: All consecutive patients with advanced pancreatobiliary cancer and a biliary stent in-situ prior to starting palliative chemotherapy were identified retrospectively from local electronic case-note records (Jan 13 to Jan 15). The primary end-point was SRE rate and the time-to-SRE (defined as time from first stenting before chemotherapy to date of SRE). Progression-free survival and overall survival were measured from the time of starting chemotherapy. Kaplan-Meier, Cox and Fine-Gray regression (univariate and multivariable) analyses were employed, as appropriate. For the analysis of time-to-SRE, death was considered as a competing event. RESULTS: Ninety-six out of 693 screened patients were eligible; 89% had a metal stent (the remainder were plastic). The median time of follow-up was 9.6 mo (range 2.2 to 26.4). Forty-one patients (43%) developed a SRE during follow-up [cholangitis (39%), stent obstruction (29%), both (32%)]. There were no significant differences in baseline characteristics between the SRE group and no-SRE groups. Recorded SRE-consequences were: none (37%), chemotherapy delay (24%), discontinuation (17%) and death (22%). The median time-to-SRE was 4.4 mo (95%CI: 3.6-5.5). Patients with severe comorbidities (P < 0.001) and patients with ≥ 2 baseline stents/biliary procedures [HR = 2.3 (95%CI: 1.2-4.44), P = 0.010] had a shorter time-to-SRE on multivariable analysis. Stage was an independent prognostic factor for overall survival (P = 0.029) in the multivariable analysis adjusted for primary tumour site, performance status and development of SRE (SRE group vs no-SRE group). CONCLUSION: SREs are common and impact on patient’s morbidity. Our results highlight the need for prospective studies exploring the role of prophylactic strategies to prevent/delay SREs. PMID:27468198

  14. In vivo imaging of superficial femoral artery (SFA) stents for deformation analysis

    NASA Astrophysics Data System (ADS)

    Ganguly, A.; Schneider, A.; Keck, B.; Bennett, N. R.; Fahrig, R.

    2008-03-01

    A high-resolution (198 μm) C-arm CT imaging system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) was optimized for imaging superficial femoral artery (SFA) stents in humans. The SFA is susceptible to the development of atherosclerotic lesions. These are typically treated with angioplasty and stent deployment. However, these stents can have a fracture rate as high as 35%. Fracture is usually accompanied by restenosis and reocclusion. The exact cause of breakage is unknown and is hypothesized to result from deforming forces due to hip and knee flexion. Imaging was performed with the leg placed in both straight and bent positions. Projection images obtained during 20 s scans with ~200° of rotation of the C-arm were back-projected to obtain 3D volumes. Using a semi-automatic software algorithm developed in-house, the stent centerlines were found and ellipses were fitted to the slice normals. Image quality was adequate for calculations in 11/13 subjects. Bending the leg was found to shorten the stents in 10/11 cases with the maximum change being 9% (12 mm in a 133 mm stent), and extend the stent in one case by 1.6%. The maximum eccentricity change was 36% with a bend angle of 72° in a case where the stent extended behind the knee.

  15. Design and fabrication of novel polymeric biodegradable stents for small caliber blood vessels by computer-aided wet-spinning.

    PubMed

    Puppi, D; Pirosa, A; Lupi, G; Erba, P A; Giachi, G; Chiellini, F

    2017-06-07

    Biodegradable stents have emerged as one of the most promising approaches in obstructive cardiovascular disease treatment due to their potential in providing mechanical support while it is needed and then leaving behind only the healed natural vessel. The aim of this study was to develop polymeric biodegradable stents for application in small caliber blood vessels. Poly[(R)-3-hydroxybutyrate-co-(R)-3-hydroxyhexanoate] (PHBHHx), a renewable microbial aliphatic polyester, and poly(ε-caprolactone), a synthetic polyester approved by the US Food and Drug Administration for different biomedical applications, were investigated as suitable polymers for stent development. A novel manufacturing approach based on computer-aided wet-spinning of a polymeric solution was developed to fabricate polymeric stents. By tuning the fabrication parameters, it was possible to develop stents with different morphological characteristics (e.g. pore size and wall thickness). Thermal analysis results suggested that material processing did not cause changes in the molecular structure of the polymers. PHBHHx stents demonstrated great radial elasticity while PCL stents showed higher axial and radial mechanical strength. The developed stents resulted able to sustain proliferation of human umbilical vein endothelial cells within two weeks of in vitro culture and they showed excellent results in terms of thromboresistivity when in contact with human blood.

  16. Iliac artery stenting in patients with poor distal runoff: Influence of concomitant infrainguinal arterial reconstruction.

    PubMed

    Timaran, Carlos H; Ohki, Takao; Gargiulo, Nicholas J; Veith, Frank J; Stevens, Scott L; Freeman, Michael B; Goldman, Mitchell H

    2003-09-01

    Inadequate infrainguinal runoff is considered an important risk factor for iliac stent failure. However, the influence of concomitant infrainguinal arterial reconstruction (CIAR) on iliac stent patency is unknown. This study evaluated the influence of CIAR on outcome of iliac angioplasty and stenting (IAS) in patients with poor distal runoff. Over 5 years (1996 to 2001), 68 IAS procedures (78 stents) were performed in 62 patients with poor distal runoff (angiographic runoff score >or=5). The SVS/AAVS reporting standards were followed to define outcome variables and risk factors. Data were analyzed with both univariate analysis (Kaplan-Meier method [K-M]) and regression analysis (Cox proportional hazards model). Indications for iliac artery stenting were disabling claudication (59%) and limb salvage (41%). Of the 68 procedures, IAS with CIAR was performed in 31 patients (46%), and IAS alone was performed in 37 patients (54%). Patients undergoing IAS with CIAR were older (P =.03) and had more extensive and multifocal iliac artery occlusive disease, with more TASC (TransAtlantic Inter-Society Consensus) type C lesions (P =.03), compared with patients undergoing IAS alone. No other significant differences in risk factors were noted. Runoff scores between patients undergoing IAS with CIAR and those undergoing IAS alone were not significantly different (median runoff scores, 6 [range, 5-8] and 7 [range, 5-9], respectively; P =.77). Primary stent patency rate at 1, 3, and 5 years was 87%, 54%, and 42%, respectively, for patients undergoing IAS with CIAR, and was 76%, 66%, and 55%, respectively, for patients undergoing IAS. Univariate analysis revealed that primary stent patency rate was not significantly different between the 2 groups (K-M, log-rank test, P =.81). Primary graft patency rate for CIAR was 81%, 52%, and 46% at 1, 3, and 5 years, respectively. Performing CIAR did not affect primary iliac stent patency (relative risk, 1.1; 95% confidence interval, 0.49-2.47; P =.81). Overall, there was a trend toward improved limb salvage in patients undergoing IAS with CIAR, compared with those undergoing IAS alone (K-M, log rank test, P =.07). In patients undergoing IAS with poor distal runoff, CIAR does not improve iliac artery stent patency. Infrainguinal bypass procedures should therefore be reserved for patients who do not demonstrate clinical improvement and possibly for those with limb-threatening ischemia.

  17. Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials).

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; Masotti, Mónica; López-Minguez, José R; Iñiguez, Andrés; Zueco, Javier; Velazquez, Maite; Cequier, Angel; Lázaro-García, Rosa; Martí, Vicens; Moris, César; Urbano-Carrillo, Cristobal; Bastante, Teresa; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-02-15

    Treatment of patients with in-stent restenosis (ISR) remains a challenge. This study sought to compare the efficacy of everolimus-eluting stents (EESs) and drug-eluting balloons (DEBs) with paclitaxel in patients with ISR. A pooled analysis of the Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS IV) and Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS V) randomized trials was performed using patient-level data. In both trials, EESs were compared with DEBs in patients with ISR (RIBS V included 189 patients with bare-metal ISR; RIBS IV included 309 patients with drug-eluting ISR). Inclusion and exclusion criteria were identical in both trials. A total of 249 patients were allocated to EES and 249 to DEB. Clinical follow-up at 1 year was obtained in all (100%) patients and late angiography (median 249 days) in 91% of eligible patients. Compared with patients treated with DEBs, patients treated with EESs obtained better short-term results (postprocedural minimal lumen diameter 2.28 ± 0.5 vs 2.12 ± 0.4 mm, p <0.0001). At follow-up, patients treated with EESs had larger in-segment minimal lumen diameter (primary end point 2.16 ± 0.7 vs 1.88 ± 0.6 mm, p <0.0001; absolute mean difference 0.28 mm; 95% confidence interval [CI] 0.16 to 0.40) and net lumen gain (1.33 ± 0.6 vs 1.00 ± 0.7 mm, p <0.0001) and had lower %diameter stenosis (19 ± 21% vs 28 ± 22%, p <0.0001) and binary restenosis rate (8.7% vs 15.7%, p = 0.02). Consistent results were observed in the in-lesion analysis. No interactions were found between the underlying stent type and treatment effects. At 1-year clinical follow-up, the composite of cardiac death, myocardial infarction, and target vessel revascularization was significantly reduced in the EES arm (8.8% vs 14.5%, p = 0.03; hazard ratio 0.59, 95% CI 0.31 to 0.94) mainly driven by a lower need for target vessel revascularization (6% vs 12.4%, p = 0.01, hazard ratio 0.46, 95% CI 0.25 to 0.86). This pooled analysis of the RIBS IV and RIBS V randomized trials demonstrates the superiority of EES over DEB in the treatment of patients with ISR. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis

    PubMed Central

    Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    Aim To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. Methods We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. Results The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19–4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05–10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57–1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94–1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56–0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12–0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03–3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54–34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36–4.50; p = 0.003, I2 = 0%). Conclusions Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary obstruction due to their removability. PMID:26859673

  19. Self-Expanding Metal Stents for the Treatment of Post-Surgical Esophageal Leaks: A Tertiary Referral Center Experience.

    PubMed

    Anderloni, Andrea; Genco, Chiara; Massidda, Marco; Di Leo, Milena; Fumagalli, Uberto Romario; Rosati, Riccardo; Correale, Loredana; Maselli, Roberta; Ferrara, Elisa Chiara; Jovani, Manol; Repici, Alessandro

    2018-06-05

    The study aimed to evaluate the effectiveness and safety of self-expanding metal stents (SEMS) in the management of post-surgical esophageal leaks. Retrospective data of consecutive patients with a post-surgical esophageal leak treated by means of a metal stent between January 2008 and December 2014 at the Humanitas Research Hospital (Milan, Italy) were extracted from a prospectively maintained register of SEMS used for benign indications, such as post-surgical benign esophageal strictures and/or leaks. The primary outcome of the study was to assess the rate of successful leak closure and to identify the variables associated with its achievement. As a secondary outcome, we evaluated the overall safety of SEMS placement and the efficacy and safety for different types of SEMS in this specific setting of patients. Leak resolution was documented with endoscopic and/or imaging studies. In the case of leak persistence, further attempts of esophageal stenting were carried out at the discretion of both endoscopists and surgeons. A total of 49 patients were included in the study (men 41 of 49, 83.7%, mean age 62.4 ± 11.9). One patient was excluded from analysis, because of death 1 day after stent insertion due to worsening of pre-existing mediastinitis. A total number of 82 stents were placed (mean number of stents per patient: 1.7) in 49 patients: 35 patients (71.4%) received a partially covered SEMS (PCSEMS) as the first stent positioned, while the remaining 14 (28.6%) received a fully covered SEMS (FCSEMS); but 1 patient (2%) died following stent insertion; therefore, data regarding therapeutic success were available for 48 patients. Stents were left in place for a mean period of 21.9 ± 15.2 days. Leak closure after the first stent placement was achieved in 22 of 48 (45.8%) patients. Of the 26 patients with failure of index stent placement, 18 patients underwent further stenting attempts (69.2%), and secondary closure of leak was achieved in 7 (38.9%) of these 18 patients. Thus, the overall success rate was 60.5% (29 of 48). On the basis of stent type, the success rate was 57.1% (8 of 14) for FCSEMS and 64.7% (22 of 34) for PCSEMS. Logistic regression analysis did not find any significant association between successful leak closure and analyzed variables. Overall mortality was 13.0%. Complication rate was 38.8% (19 of 49 patients). The use of SEMS is an effective and safe option for post-surgical esophageal leaks, with no evidence of any significant influence of stent type on outcome. © 2018 S. Karger AG, Basel.

  20. Evaluation and analysis of Seasat-A scanning multichannel Microwave Radiometer (SMMR) Antenna Pattern Correction (APC) algorithm

    NASA Technical Reports Server (NTRS)

    Kitzis, J. L.; Kitzis, S. N.

    1979-01-01

    The brightness temperature data produced by the SMMR final Antenna Pattern Correction (APC) algorithm is discussed. The algorithm consisted of: (1) a direct comparison of the outputs of the final and interim APC algorithms; and (2) an analysis of a possible relationship between observed cross track gradients in the interim brightness temperatures and the asymmetry in the antenna temperature data. Results indicate a bias between the brightness temperature produced by the final and interim APC algorithm.

  1. Diagnostic accuracy of dual-source computed tomography angiography for the detection of coronary in-stent restenosis: A systematic review and meta-analysis.

    PubMed

    Liu, Wen-Jun; Li, Gui-Zhen; Liu, Hai-Feng; Lei, Jun-Qiang

    2018-04-01

    We sought to perform a meta-analysis to comprehensively evaluate the diagnostic accuracy of dual-source computed tomography angiography (DSCTA) in detecting coronary in-stent restenosis (CISR) when compared to invasive coronary angiography. The stent-based research studies in which DSCTA was used as diagnostic tool for CISR, as recent as of October 2017, from several reputed scientific libraries (PubMed, Embase, Scopus, The Cochrane Library, and Web of Science) were evaluated. Study inclusion, data extraction, and risk bias assessment were conducted by two researchers independently. Pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under summary receiver operator characteristics (SROC) curve (AUC) were calculated to assess the diagnostic value. In addition, heterogeneity and subgroup analysis were also carried out. A total of 13 studies with a total of 894 patients and 1384 assessable stents were included. The pooled results of DSCTA diagnosing CISR were as follows: SEN 0.92 (95% confidence interval [CI] 0.87-0.96), SPE 0.91 (95% CI 0.87-0.94), PLR 9.83 (95% CI 6.93-13.94), NLR 0.09 (95% CI 0.05-0.15), DOR 114.73 (95% CI 64.12-205.28), and AUC 0.97 (95% CI 0.95-0.98), respectively. The subgroup analysis result suggested that DSTCA performed significantly better in CISR detection when the stent diameter was ≥3 mm compared with the stent diameter <3 mm: (0.98 [0.97-0.99] vs 0.82 [0.79-0.86]) with P < .05. This study revealed that DSCTA has excellent diagnostic performance for detecting CISR and may serve as an alternative for further patient evaluation with CISR, especially for stent diameter ≥3 mm. © 2018 Wiley Periodicals, Inc.

  2. TOKYO criteria 2014 for transpapillary biliary stenting.

    PubMed

    Isayama, Hiroyuki; Hamada, Tsuyoshi; Yasuda, Ichiro; Itoi, Takao; Ryozawa, Shomei; Nakai, Yousuke; Kogure, Hirofumi; Koike, Kazuhiko

    2015-01-01

    It is difficult to carry out meta-analyses or to compare the results of different studies of biliary stents because there is no uniform evaluation method. Therefore, a standardized reporting system is required. We propose a new standardized system for reporting on biliary stents, the 'TOKYO criteria 2014', based on a consensus among Japanese pancreatobiliary endoscopists. Instead of stent occlusion, we use recurrent biliary obstruction, which includes occlusion and migration. The time to recurrent biliary obstruction was estimated using Kaplan-Meier analysis with the log-rank test. We can evaluate both plastic and self-expandable metallic stents (uncovered and covered). We also propose specification of the cause of recurrent biliary obstruction, identification of complications other than recurrent biliary obstruction, indication of severity, measures of technical and clinical success, and a standard for clinical care. Most importantly, the TOKYO criteria 2014 allow comparison of biliary stent quality across studies. Because blocked stents can be drained not only using transpapillary techniques but also by an endoscopic ultrasonography-guided transmural procedure, we should devise an evaluation method that includes transmural stenting in the near future. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  3. Drug-eluting stents and glycoprotein IIb/IIIa inhibitors in vessels at low anatomic risk: a retrospective analysis of previously published data from the Basel Stent Kosten Effektivitäts Trial.

    PubMed

    Jeger, Raban V; Brunner-La Rocca, Hans Peter; Hunziker, Patrick R; Tsakiris, Dimitrios A; Kaiser, Christoph A; Pfisterer, Matthias E

    2009-12-01

    Drug-eluting stents (DESs) are associated with late stent thromboses, but the exact mechanism of action is unknown. The goal of this article was to assess the clinical interaction of glycoprotein IIb/IIIa inhibitors (GPIs) with different stent and vessel types in unselected patients undergoing percutaneous coronary intervention (PCI). This was a predefined retrospective analysis of the randomized controlled Basel Stent Kosten Effektivitats Trial (BASKET), which compared DES with bare-metal stents (BMSs) in patients undergoing PCI. Patients were compared for major adverse clinical events in relation to GPI use (abciximab and tirofiban) after 18 months. In a subgroup analysis prespecified in the study protocol, specific regard was given to angiographic groups at different risk levels for late events (high-risk vessels [ie, small vessels with a diameter <3.0 mm and saphenous vein grafts], and low-risk vessels [ie, large native vessels > or =3.0 mm]). Baseline differences between patients with or without GPI use were identified and incorporated into a multivariable Cox proportional hazards regression analysis if different at a <0.05 level. A total of 826 patients (650 males, 176 females) were enrolled in BASKET; 301 (36%) received GPI therapy. Of these 301 patients, 255 (85%) received abciximab and 46 (15%) received tirofiban. After 18 months, the rate of cardiac death and nonfatal myocardial infarction was higher in patients with GPI use than in those without GPI use (35/301 [12%] vs 32/525 [6%]; P = 0.005). In patients undergoing PCI in anatomically low-risk vessels and receiving GPI therapy, there was a higher rate of cardiac death and nonfatal myocardial infarction at 18 months with a DES versus a BMS (22/151 [15%] vs 3/66 [5%]; P = 0.033). In patients undergoing PCI in anatomically low-risk vessels and without GPI therapy, there was no significant difference for cardiac death and nonfatal myocardial infarction (DES vs BMS, 11/207 [5%] vs 6/134 [4%]). In the multivariable analysis, GPI use (hazard ratio = 2.93; 95% CI, 1.53-5.63; P = 0.001) and age (hazard ratio = 1.034 per year increase; 95% CI, 1.008-1.062; P = 0.012) remained the only significant independent predictors of outcome. Interaction of stent type and GPI use was significant (P = 0.006). This retrospective analysis of the BASKET data found that GPIs and DESs used in patients with large native vessels may have an adverse interaction in terms of late stent thromboses. However, large prospective studies are needed to confirm these findings. Copyright 2009 Excerpta Medica Inc. All rights reserved.

  4. Relationship between stent characteristics and treatment outcomes in endoscopic transmural drainage of uncomplicated pancreatic pseudocysts.

    PubMed

    Bang, Ji Young; Wilcox, C Mel; Trevino, Jessica M; Ramesh, Jayapal; Hasan, Muhammad; Hawes, Robert H; Varadarajulu, Shyam

    2014-10-01

    Transmural stents are placed at endoscopy to drain pancreatic fluid collections. This study evaluated the relationship between stent placement and treatment outcomes in patients undergoing endoscopic transmural drainage of uncomplicated pancreatic pseudocysts. This is a retrospective study of all patients who underwent endoscopic drainage of uncomplicated pancreatic pseudocysts over a 10-year period. After dilating the transmural tracts in the range of 8-15 mm, single or multiple, 7 or 10Fr double-pigtail plastic stents were deployed. The main outcome measure was to evaluate the relationship between stent characteristics and the number of endoscopic interventions required to achieve resolution of the pancreatic pseudocyst (treatment success). Of 122 patients, 45 (36.9%) had 10Fr stents of which 30 patients (66.7%) had more than one stent; the remaining 77 (63.1%) patients had 7Fr stents of which 56 (72.7%) had more than one stent. The overall treatment success was 94.3%. Treatment was successful in 102 patients (83.6%) with one intervention; 13 patients (10.7%) required re-intervention for successful drainage and 7 patients (5.7%) failed endoscopic treatment. There was no significant difference in the number of interventions required for treatment success between patients with 7 or 10Fr stents (one intervention required in 87.7 vs. 90.5%, respectively; p = 0.766) and between patients with 1 or >1 stent (one intervention required in 88.9 vs. 88.6%, respectively; p = 0.999). On multiple logistic regression analysis, the stent size (OR 1.54; 95% CI 0.23-10.4) and number (OR 1.15; 95% CI 0.25-5.25) were not associated with the number of interventions required for treatment success when adjusted for pseudocyst size, location, drainage modality, the presence or absence of pancreatic duct stent and luminal compression. There appears to be no relationship between the number of interventions required for treatment success and stent characteristics in patients undergoing endoscopic transmural drainage of uncomplicated pancreatic pseudocysts.

  5. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    PubMed Central

    Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho

    2007-01-01

    Objective We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Materials and Methods Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50-80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2-81 weeks). Results Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. Conclusion The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates. PMID:17923784

  6. Factors affecting primary patency of stenting for TransAtlantic Inter-Society (TASC II) type B, C, and D iliac occlusive disease.

    PubMed

    Kavaliauskienė, Zana; Benetis, Rimantas; Inčiūra, Donatas; Aleksynas, Nerijus; Kaupas, Rytis Stasys; Antuševas, Aleksandras

    2014-01-01

    The purpose of our study was to evaluate 1- and 2-year results and the influence of risk factors on the outcome in the patients undergoing iliac artery stenting for TASC II type B, C, and D iliac lesions. In this prospective nonrandomized study conducted between April 15, 2011, and April 15, 2013, 316 patients underwent angiography with a diagnosis of aortoiliac atherosclerotic disease. Of these, 62 iliac endovascular procedures (87 stents) were performed in 54 patients. The indications for revascularization were disabling claudication (Rutherford 2, 5.9%; Rutherford 3, 35.2%), rest pain (Rutherford 4, 22.2%), and gangrene (Rutherford 5, 16.7%). The overall complication rate was 9.2%. The cumulative primary stent patency at 1 and 2 years was 83.0%±5.2% and 79.9%±5.8%, respectively. Early stent thrombosis in ≤30 days was detected in two patients (3.7%). The primary patency rates for the stents ≤61mm at 12 and 24 months were 90.6%±4.5% and 86.6%±5.8%, respectively; those for the stents >61mm were 67.7%±10.9% and 60.2%±12.0%, respectively (P=0.016). The multivariate Cox regression analysis enabled the localization of a stent in both the CIA and the EIA (hazard ratio [HR], 3.3; 95% confidence interval [CI], 1.1-9.5; P=0.021) and poor runoff (HR, 3.2; 95%, CI 1.0-10.0; P=0.047) as independent predictors of decreased stent primary patency. The localization of a stent in both iliac (CIA and EIA) arteries and poor runoff significantly reduce the primary stent patency. Patients with stents >61mm have a higher risk of stent thrombosis or in-stent restenosis development. Copyright © 2014 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  7. Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial

    PubMed Central

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-01-01

    OBJECTIVES: Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS: A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS: At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS: WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer. PMID:26372507

  8. Automatic segmentation of the wire frame of stent grafts from CT data.

    PubMed

    Klein, Almar; van der Vliet, J Adam; Oostveen, Luuk J; Hoogeveen, Yvonne; Kool, Leo J Schultze; Renema, W Klaas Jan; Slump, Cornelis H

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion characteristics of stent grafts will be beneficial for designing future devices. In addition, analysis of stent graft movement in individual patients in vivo can be valuable for predicting stent graft failure in these patients. To be able to gather information on stent graft motion in a quick and robust fashion, we propose an automatic method to segment stent grafts from CT data, consisting of three steps: the detection of seed points, finding the connections between these points to produce a graph, and graph processing to obtain the final geometric model in the form of an undirected graph. Using annotated reference data, the method was optimized and its accuracy was evaluated. The experiments were performed using data containing the AneuRx and Zenith stent grafts. The algorithm is robust for noise and small variations in the used parameter values, does not require much memory according to modern standards, and is fast enough to be used in a clinical setting (65 and 30s for the two stent types, respectively). Further, it is shown that the resulting graphs have a 95% (AneuRx) and 92% (Zenith) correspondence with the annotated data. The geometric model produced by the algorithm allows incorporation of high level information and material properties. This enables us to study the in vivo motions and forces that act on the frame of the stent. We believe that such studies will provide new insights into the behavior of the stent graft in vivo, enables the detection and prediction of stent failure in individual patients, and can help in designing better stent grafts in the future. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. In vitro comparison of intracranial stent visibility using various concentrations of gadolinium contrast agent under 1.5 T and 3 T MR angiography.

    PubMed

    Chiang, Chen-Hua; Tseng, Ying-Chi; Chen, Ai-Chi; Huang, Yen-Lin; Chen, David Yen-Ting; Chen, Chi-Jen; Lin, Yen-Kuang; Hsu, Hui-Ling

    2017-04-01

    MR angiography (MRA) is an increasingly used evaluation method following intracranial stenting. However, the various artifacts created by the stent limit this technique. The purpose of this study was to investigate the effects of various concentrations of gadolinium contrast agent on the visibility and signal characteristics of two stents using the a contrast enhanced MRA technique. Two intracranial stents (Enterprise and Helistent) were placed in polyvinyl chloride tubes as vascular phantoms. They were filled with six different doses of gadolinium contrast agent (1.0, 2.0, 4.0, 6.0, 8.0, and 10.0 mmol/L dimeglumine gadopentetate, respectively) and imaged using 3 T and 1.5 T MR systems. Relative in-stent signal (RIS) was calculated and artificial luminal narrowing (ALN) was obtained using pixel by pixel analysis. The Enterprise stent, performed in both 1.5 T and 3 T MR systems, showed mean RIS values much less than those for the Helistent for all different doses of gadolinium solution. Increased gadolinium concentration resulted in a gradual reduction in RIS values in the Enterprise group. Also, ALN in the Enterprise group showed no or little change with various gadolinium doses. The Enterprise stent demonstrated good luminal visibility regardless of gadolinium concentration. The relative in-stent signals were more predictable in the Enterprise stent with various doses of gadolinium. Therefore, the Enterprise stent has been shown to provide better in-stent visibility compared with the Helistent using various gadolinium doses. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Impact of stent length on clinical outcomes of first-generation and new-generation drug-eluting stents.

    PubMed

    Konishi, Hirokazu; Miyauchi, Katsumi; Dohi, Tomotaka; Tsuboi, Shuta; Ogita, Manabu; Naito, Ryo; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Daida, Hiroyuki

    2016-04-01

    The aim of this study is to compare first- and new-generation drug-eluting stents (DESs) which are implanted in long lesion. Stent length is known to be a predictor of adverse events after percutaneous coronary intervention (PCI), even with the first-generation DESs. The introduction of new-generation DESs has reduced the rates of adverse clinical events. However, the impact of stent length on long-term clinical outcomes is not well known. A total of 1181 consecutive patients who underwent PCI using either a first-generation DES (n = 885) or a new-generation DES (n = 296) between 2004 and 2011 were investigated. In each of the stent groups, the patients were divided into two groups by stent length (>32 and ≤32 mm) and compared. During the follow-up period, the incidence of major adverse cardiac events (MACEs) was significantly higher for patients with long stents implanted than with short stents (P < 0.01; log-rank test) in the first-generation DES group. However, there was no difference in the incidence of MACEs between the long- and short-stent groups in the new-generation DES group (P = 0.24; log-rank test). On multivariate Cox regression analysis, stent length was not associated with adverse events in the new-generation DES groups [hazard ratio (HR) 0.87; 95 % confidence interval (95 % CI) 0.71-1.04; P = 0.14]. Implanted stent length was significantly associated with a higher risk of MACEs in patients who received first-generation DESs, but not in patients who received the new-generation DESs.

  11. Pathological mechanisms of left main stent failure.

    PubMed

    Mori, Hiroyoshi; Torii, Sho; Harari, Emanuel; Jinnouchi, Hiroyuki; Brauman, Ryan; Smith, Samantha; Kutys, Robert; Fowler, David; Romero, Maria; Virmani, Renu; Finn, Aloke V

    2018-07-15

    Despite the increasing use of left main (LM) percutaneous coronary intervention (LM-PCI), there have been no pathological studies devoted to understanding the causes of LM stent failure. We aimed to systematically determine the pathological mechanisms of LM stent failure. From the CVPath Stent registry, a total of 46 lesions were identified to have LM-PCI. Pathologic stent failure (PSF) was defined as stent thrombosis, restenosis and in-stent chronic total occlusion (CTO). Failed and patent LM stented lesions were pathologically assessed to determine predictors of PSF. Malapposition and uncovered struts were numerically greater in the LM ostium, body, and bifurcation while neointimal thickness was relatively greater in bifurcation and proximal circumflex. In this study cohort, half of the lesions (n = 23) showed PSF. Stent thrombosis (ST, n = 18) was the major mode of PSF followed by in-stent CTO (n = 4) and restenosis (n = 1). Failed lesions showed significantly greater prevalence of malapposition >20% of struts/section (65% vs. 13%, P < 0.01), stent struts crossing an ostial side branch >30% of the circumference (48% vs. 13%, P < 0.01) and uncovered struts >30% (57% vs. 18%, P = 0.03). In multivariate analysis, the prevalence of malapposition >20% was the strongest risk factor for PSF (Odds ratio 8.0, 95% confidence interval 1.8-45.4, P < 0.01) followed by struts crossing an ostial side branch >30% (Odds ratio 4.2, 95% confidence interval 0.8-24.7, P = 0.09). Our data demonstrate the main pathological predictors for LM stent failure are malapposition and struts crossing an ostial side branch and suggest that imaging-guided PCI may be important. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type.

    PubMed

    Camenzind, Edoardo; Boersma, Eric; Wijns, William; Mauri, Laura; Rademaker-Havinga, Tessa; Ordoubadi, Farzin Fath; Suttorp, Maarten J; Al Kurdi, Mohammad; Steg, Ph Gabriel

    2014-08-01

    To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  13. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents.

    PubMed

    Teichgräber, Ulf K; de Bucourt, Maximilian

    2012-01-01

    OJECTIVES: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Extraction Strings for Ureteric Stents: Is There an Increased Risk for Urinary Tract Infections?

    PubMed

    Fröhlich, Maryna; Fehr, Jan; Sulser, Tullio; Eberli, Daniel; Mortezavi, Ashkan

    To evaluate urinary tract infections associated with placement of ureteric stents, we performed a retrospective study and compared rates between patients with and patients without an extraction string attached to the ureteric stent. Indwelling ureteric stents are routinely removed by cystoscopy. If an extraction string has been connected to the stent at the time of placement, however, the removal can be performed without an invasive procedure. Concerns exist regarding the risk for an unintentional dislocation, increased stent-related discomfort, or an increase of the post-operative urinary tract infection rate. All elective transurethral ureteric stent placements performed between November 2011 and December 2012 in our department were included for this investigation. Urinary tract infection was defined according to the Centers for Disease Control and Prevention (CDC)/National Healthcare Safety Network (NHSN) surveillance definition of health-care-associated infections. Patients with an existing urinary tract infection at the time of admission were excluded from the analysis. A total of 342 patients receiving ureteric stents were evaluated regarding post-operative urinary tract infections. Of these patients, 127 (37.1%) had an extraction string and 215 (62.9%) a stent without a string. The total urinary tract infection rate was 6.4% with no significant difference between the two groups (7.9% vs. 5.6%, p = 0.49). In the present study, we did not observe an increased rate of post-operative urinary tract infections in patients with an extraction string attached to the ureteral stent. Extraction string is a good option for patients to avoid cystoscopic stent removal.

  15. Clinical effect of pancreaticojejunostomy with a long-internal stent during pancreaticoduodenectomy in patients with a main pancreatic duct of small diameter.

    PubMed

    Yamamoto, Tomohisa; Satoi, Sohei; Yanagimoto, Hiroaki; Hirooka, Satoshi; Yamaki, So; Ryota, Hironori; Kotsuka, Masaya; Matsui, Yoichi; Kon, Masanori

    2017-06-01

    Post-operative pancreatic fistula (POPF) is one of the most common causes of death following pancreaticoduodenectomy (PD). The aim of this study was to evaluate the clinical effect of a long-internal stent on the development of POPF in patients with a main pancreatic duct diameter of 3 mm or less. Patients (N = 108) with a main pancreatic duct (≤3 mm) who underwent PD were included in this single-institution historical control study. Between January 2012 and December 2013, 54 patients had undergone PJ with a long-internal stent across the duct-to-mucosa anastomosis (long-stent group), and between February 2009 and December 2011, 54 patients had undergone PJ without a stent (control). There was no significant difference between groups (long-stent vs control) in the incidence of POPF (70% vs. 56%, p = 0.110) and grade B/C POPF (26% vs. 26%, p = 1.000). Univariate analysis identified body mass index, extent of blood loss and soft pancreatic parenchyma as risk factors related to POPF. Multivariate analysis identified extent of blood loss and soft pancreatic parenchyma as significant risk factors. Placement of a long-internal stent during PJ did not reduce POPF after PD in patients with a main pancreatic duct of small diameter. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  16. iStent with Phacoemulsification versus Phacoemulsification Alone for Patients with Glaucoma and Cataract: A Meta-Analysis

    PubMed Central

    Malvankar-Mehta, Monali S.; Iordanous, Yiannis; Chen, Yufeng Nancy; Wang, Wan Wendy; Patel, Sangita Shantilal; Costella, John; Hutnik, Cindy M. L.

    2015-01-01

    Background Minimally invasive glaucoma surgeries (MIGS) have attracted significant attention, as they have been reported to lower intra-ocular pressure (IOP) and have an excellent safety profile. The iStent is an example of a minimally invasive glaucoma device that has received particular attention due to its early and wide spread utilization. There is a growing body of evidence supporting its use at the time of phacoemulsification to help lower IOP. However, it is still not clear how much of the IOP lowering effect can be attributed to the iStent, the crystalline lens extraction or both when inserted concurrently at the time of phacoemulsification. This has been an important issue in understanding its potential role in the glaucoma management paradigm. Purpose To conduct a systematic review and meta-analysis comparing the IOP lowering effect of iStent insertion at the time of phacoemulsification versus phacoemulsification alone for patients with glaucoma and cataracts. Methods A systematic review was conducted utilizing various databases. Studies examining the IOP lowering effect of iStent insertion in combination with phacoemulsification, as well as studies examining the IOP lowering effect of phacoemulsification alone were included. Thirty-seven studies, reporting on 2495 patients, met the inclusion criteria. The percentage reduction in IOP (IOPR%) and mean reduction in topical glaucoma medications after surgery were determined. The standardized mean difference (SMD) was computed as a measure of the treatment effect for continuous outcomes taking into account heterogeneity. Fixed-effect and random-effect models were applied. Results A 4% IOP reduction (IOPR%) from baseline occurred following phacoemulsification as a solo procedure compared to 9% following an iStent implant with phacoemulsification, and 27% following 2 iStents implants with phacoemulsification. Compared with cataract extraction alone, iStent with phacoemulsification resulted in significant reduction in the post-operative IOP (IOPR%) (SMD = -0.46, 95% CI: [-0.87, -0.06]). A weighted mean reduction in the number of glaucoma medications per patient was 1.01 following phacoemulsification alone compared to 1.33 after one iStent implant with phacoemulsification, and 1.1 after 2 iStent implants with phacoemulsification. Compared to cataract extraction alone, iStent with cataract extraction showed a significant decrease in the number of glaucoma medications (SMD = -0.65, 95% CI: [-1.18, -0.12]). Funnel plots suggested the absence of publication bias. Conclusion Both iStent implantation with concurrent phacoemulsification and phacoemulsification alone result in a significant decrease in IOP and topical glaucoma medications. In terms of both reductions, iStent with phacoemulsification significantly outperforms phacoemulsification alone. PMID:26147908

  17. Quantitative multi-modality imaging analysis of a bioabsorbable poly-L-lactic acid stent design in the acute phase: a comparison between 2- and 3D-QCA, QCU and QMSCT-CA.

    PubMed

    Bruining, Nico; Tanimoto, Shuzou; Otsuka, Masato; Weustink, Annick; Ligthart, Jurgen; de Winter, Sebastiaan; van Mieghem, Carlos; Nieman, Koen; de Feyter, Pim J; van Domburg, Ron T; Serruys, Patrick W

    2008-08-01

    To investigate if three-dimensional (3D) based quantitative techniques are comparable to each other and to explore possible differences with respect to the reference method of 2D-QCA in the acute phase and to study whether non-invasive MSCT could potentially be applied to quantify luminal dimensions of a stented coronary segment with a novel bioabsorable drug-eluting stent made of poly-l-lactic-acid (PLLA). Quantitative imaging data derived from 16 patients enrolled at our institution in a first-in-man trial (ABSORB) receiving a biodegradable stent and who were imaged with standard coronary angiography and intravascular ultrasound were compared. Shortly, after stenting the patients also underwent a MSCT procedure. Standard 2D-QCA showed significant smaller stent lengths (p < 0.01). Although, the absolute measured stent diameters and areas by 2D-QCA tend to be smaller, the differences failed to be statistically different when compared to the 3D based quantitative modalities. Measurements made by non-invasive QMSCT-CA of implanted PLLA stents appeared to be comparable to the other 3D modalities without significant differences. Three-dimensional based quantitative analyses showed similar results quantifying luminal dimensions as compared to 2D-QCA during an evaluation of a new bioabsorbable coronary stent design in the acute phase. Furthermore, in biodegradable stents made of PLLA, non-invasive QMSCT-CA can be used to quantify luminal dimensions.

  18. Economic modeling of new stent platforms to evaluate cost effectiveness: analysis of the TAXUS Liberté versus TAXUS express stents.

    PubMed

    Turco, Mark A; Kansal, Anuraag R; Stern, Sean; Amorosi, Stacey L; Underwood, Paul L; Lissovoy, Greg D E; Dawkins, Keith D

    2012-08-01

    With the changing health care environment, cost effectiveness is an important adjunct to clinical investigation when assessing new medical devices. This study presents an economic model to evaluate cost effectiveness of coronary stents. Markov modeling was developed comparing total costs (Medicare payer perspective) between TAXUS Liberté and TAXUS Express based on 3-year clinical outcomes from the TAXUS ATLAS Small Vessel and Long Lesion trials. The TAXUS Liberté 2.25-mm stent provided cost savings relative to TAXUS Express from a payer perspective ($17,605 vs. $20,281), driven by reduced target vessel revascularization (0.16 events/patient vs. 0.33 events/patient). In probabilistic sensitivity analyses, TAXUS Liberté was less costly with fewer major adverse cardiac events in over 99% of parameter sets. The TAXUS Liberté Long (38 mm) stent was cost neutral relative to TAXUS Express from a payer perspective ($18,545 vs. $18,551) with fewer myocardial infarctions and cardiac deaths. Accounting for angiography-driven revascularizations, TAXUS Liberté 2.25 mm still provided cost savings relative to TAXUS Express ($16,822 vs. $19,139), although TAXUS Liberté Long was more expensive than TAXUS Express ($17,886 vs. $17,652). From a hospital perspective, TAXUS Liberté Long provided cost savings up to a price premium of $671/stent, driven by fewer stents employed per patient. This analysis confirms the utility of economic modeling in assessing new stent platforms. TAXUS Liberté 2.25 mm is economically dominant relative to TAXUS Express when treating small vessels. TAXUS Liberté Long is cost neutral to modestly more costly than TAXUS Express 2.25 mm from a payer perspective. ©2012, Wiley Periodicals, Inc.

  19. Endoscopic Drainage of >50% of Liver in Malignant Hilar Biliary Obstruction Using Metallic or Fenestrated Plastic Stents

    PubMed Central

    Kerdsirichairat, Tossapol; Arain, Mustafa A; Attam, Rajeev; Glessing, Brooke; Bakman, Yan; Amateau, Stuart K; Freeman, Martin L

    2017-01-01

    Objectives: Endoscopic drainage of complex hilar tumors has generally resulted in poor outcomes. Drainage of >50% of liver volume has been proposed as optimal, but not evaluated using long multifenestrated plastic stents (MFPS) or self-expanding metal stents (SEMS). We evaluated outcomes of endoscopic drainage of malignant hilar strictures using optimal strategy and stents, and determined factors associated with stent patency, survival, and complications. Methods: Cross-sectional study was conducted at an academic center over 5 years. MFPS (10 French or 8.5 French) or open-cell SEMS were used for palliation of unresectable malignant hilar strictures, with imaging-targeted drainage of as many sectors as needed to drain >50% of viable liver volume. Risk factors were evaluated using regression analysis. The cumulative risk was assessed using Kaplan–Meier analysis. Results: 77 patients with malignant hilar biliary strictures (median Bismuth IV) underwent targeted stenting (41 MFPS and 36 SEMS). Comparing MFPS vs. SEMS, technical success (95.1 vs. 97.2%, P=0.64), clinical success (75.6 vs. 83.3%, P=0.40), frequency of multiple stents (23/41 vs. 25/36, P=0.19), survival and adverse events were similar, but stent patency was significantly shorter (P<0.0001). Factors associated with survival were Karnofsky score and serum bilirubin level at presentation. Outcomes were independent of Bismuth class with acceptable results in Bismuth III and IV. Conclusions: Endoscopic biliary drainage with MFPS or open-cell SEMS targeting >50% of viable liver resulted in effective palliation in patients with complex malignant hilar biliary strictures. Patency was shorter in the MFPS group, but similar survival and complications were found when comparing MFPS and SEMS group. PMID:28858292

  20. Endoscopic Drainage of >50% of Liver in Malignant Hilar Biliary Obstruction Using Metallic or Fenestrated Plastic Stents.

    PubMed

    Kerdsirichairat, Tossapol; Arain, Mustafa A; Attam, Rajeev; Glessing, Brooke; Bakman, Yan; Amateau, Stuart K; Freeman, Martin L

    2017-08-31

    Endoscopic drainage of complex hilar tumors has generally resulted in poor outcomes. Drainage of >50% of liver volume has been proposed as optimal, but not evaluated using long multifenestrated plastic stents (MFPS) or self-expanding metal stents (SEMS). We evaluated outcomes of endoscopic drainage of malignant hilar strictures using optimal strategy and stents, and determined factors associated with stent patency, survival, and complications. Cross-sectional study was conducted at an academic center over 5 years. MFPS (10 French or 8.5 French) or open-cell SEMS were used for palliation of unresectable malignant hilar strictures, with imaging-targeted drainage of as many sectors as needed to drain >50% of viable liver volume. Risk factors were evaluated using regression analysis. The cumulative risk was assessed using Kaplan-Meier analysis. 77 patients with malignant hilar biliary strictures (median Bismuth IV) underwent targeted stenting (41 MFPS and 36 SEMS). Comparing MFPS vs. SEMS, technical success (95.1 vs. 97.2%, P=0.64), clinical success (75.6 vs. 83.3%, P=0.40), frequency of multiple stents (23/41 vs. 25/36, P=0.19), survival and adverse events were similar, but stent patency was significantly shorter (P<0.0001). Factors associated with survival were Karnofsky score and serum bilirubin level at presentation. Outcomes were independent of Bismuth class with acceptable results in Bismuth III and IV. Endoscopic biliary drainage with MFPS or open-cell SEMS targeting >50% of viable liver resulted in effective palliation in patients with complex malignant hilar biliary strictures. Patency was shorter in the MFPS group, but similar survival and complications were found when comparing MFPS and SEMS group.

  1. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    PubMed

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  2. Ureteral stenting can be a negative predictor for successful outcome following shock wave lithotripsy in patients with ureteral stones.

    PubMed

    Kang, Dong Hyuk; Cho, Kang Su; Ham, Won Sik; Chung, Doo Yong; Kwon, Jong Kyou; Choi, Young Deuk; Lee, Joo Yong

    2016-11-01

    To evaluate ureteral stenting as a negative predictive factor influencing ureteral stone clearance and to estimate the probability of one-session success in shock wave lithotripsy (SWL) patients with a ureteral stone. We retrospectively reviewed the medical records of 1,651 patients who underwent their first SWL. Among these patients, 680 had a ureteral stone measuring 4-20 mm and were thus eligible for our study. The 57 patients who underwent ureteral stenting during SWL were identified. Maximal stone length (MSL), mean stone density (MSD), skin-to-stone distance (SSD), and stone heterogeneity index (SHI) were determined by pre-SWL noncontrast computed tomography. After propensity score matching, 399 patients were extracted from the total patient cohort. There were no significant differences between stenting and stentless groups after matching, except for a higher one-session success rate in the stentless group (78.6% vs. 49.1%, p=0.026). In multivariate analysis, shorter MSL, lower MSD, higher SHI, and absence of a stent were positive predictors for one-session success in patients who underwent SWL. Using cutoff values of MSL and MSD obtained from receiver operator curve analysis, in patients with a lower MSD (≤784 HU), the success rate was lower in those with a stent (61.1%) than in those without (83.5%) (p=0.001). However, in patients with a higher MSL (>10 mm), the success rate was lower in those with a stent (23.6%) than in those without (52.2%) (p=0.002). Ureteral stenting during SWL was a negative predictor of one-session success in patients with a ureteral stone.

  3. Angiographic patterns of restenosis with 2nd generation drug-eluting stent: comparative analysis from a 10-year single-center experience .

    PubMed

    Lee, Sahmin; Yoon, Chang-Hwan; Oh, Il-Young; Suh, Jung-Won; Cho, Young-Seok; Cho, Goo-Yeong; Chae, In-Ho; Choi, Dong-Ju; Youn, Tae-Jin

    2015-01-01

    The angiographic features of restenosis contain prognostic information. However, restenosis patterns of the new generation drug-eluting stents (DES), everolimus-(EES) and resolute zotarolimus-eluting stent (ZES) have not been described.A total of 210 consecutive patients with DES restenosis were enrolled from 2003 to 2012. We analyzed 217 restenotic lesions after DES implantation, and compared the morphologic characteristics of the 2nd generation DES restenosis to those of restenosis with 2 first generation DES, sirolimus-(SES) and paclitaxel-eluting stent (PES).Baseline characteristics were comparable between the different stent groups. The incidence of focal restenosis was significantly lower for PES than the other stents (49.5% versus 87.0%, 76.2%, and 82.1% for PES versus SES, EES, and ZES, respectively, P < 0.001). When considering the pattern of restenosis solely within the stent margins, a further clear distinction between PES and other stents was observed (40.0% versus 92.9%, 88.9%, and 81.2% in PES versus SES, EES, and ZES, respectively, P < 0.001). There were no significant differences in restenosis patterns among SES, EES, and ZES. In multivariate analysis, PES implantation, hypertension, and age were associated with non-focal type of restenosis after DES implantation. After the introduction of EES and ZES into routine clinical practice in 2008, focal restenosis significantly increased from 63.9% to 76.7% and diffuse restenosis significantly decreased from 26.4% to 11.0% (P = 0.045).Focal restenosis was the most common pattern of restenosis in the new generation DES and the incidence of diffuse restenosis significantly decreased with the introduction of the 2nd generation DES.

  4. 75 FR 12217 - Notice of Availability for Comments Regarding the Planned Environmental Assessment Interim Report...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-15

    ... public comments for a planned Environmental Assessment. The Corps is directed to conduct a study of.... The study is structured as a series of interim reports. Interim Report IIIa, limited to the impacts of.... Comments are requested to assist in determining the level of analysis and impacts to be considered for...

  5. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    PubMed Central

    van Halsema, Emo E; Rauws, Erik AJ; Fockens, Paul; van Hooft, Jeanin E

    2015-01-01

    AIM: To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). METHODS: A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher’s exact test. RESULTS: A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P < 0.001) and stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P < 0.001). The overall perforation rate was 1.2%. Bleeding was reported in 4.1% of patients, including major bleeding in 0.8%. The median stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. CONCLUSION: The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO. PMID:26604654

  6. Progressive Occlusion of Small Saccular Aneurysms Incompletely Occluded After Stent-Assisted Coil Embolization : Analysis of Related Factors and Long-Term Outcomes.

    PubMed

    Lim, Jeong Wook; Lee, Jeongjun; Cho, Young Dae

    2017-08-08

    Incompletely occluded aneurysms after coil embolization are subject to recanalization but occasionally progress to a totally occluded state. Deployed stents may actually promote thrombosis of coiled aneurysms. We evaluated outcomes of small aneurysms (<10 mm) wherein saccular filling with contrast medium was evident after stent-assisted coiling, assessing factors implicated in subsequent progressive occlusion. Between September 2012 and June 2016, a total of 463 intracranial aneurysms were treated by stent-assisted coil embolization. Of these, 132 small saccular aneurysms displayed saccular filling with contrast medium in the immediate aftermath of coiling. Progressive thrombosis was defined as complete aneurysmal occlusion at the 6‑month follow-up point. Rates of progressive occlusion and factors predisposing to this were analyzed via binary logistic regression. In 101 (76.5%) of the 132 intracranial aneurysms, complete occlusion was observed in follow-up imaging studies at 6 months. Binary logistic regression analysis indicated that progressive occlusion was linked to smaller neck diameter (odds ratio [OR] = 1.533; p = 0.003), hyperlipidemia (OR = 3.329; p = 0.036) and stent type (p = 0.031). The LVIS stent is especially susceptible to progressive thrombosis, more so than Neuroform (OR = 0.098; p = 0.008) or Enterprise (OR = 0.317; p = 0.098) stents. In 57 instances of progressive thrombosis, followed for ≥12 months (mean 25.0 ± 10.7 months), 56 (98.2%) were stable, with minor recanalization noted once (1.8%) and no major recanalization. Aneurysms associated with smaller diameter necks, hyperlipidemic states and LVIS stent deployment may be inclined to possible thrombosis, if occlusion immediately after stent-assisted coil embolization is incomplete. In such instances, excellent long-term durability is anticipated.

  7. Quantification of thrombus formation in malapposed coronary stents deployed in vitro through imaging analysis.

    PubMed

    Brown, Jonathan; O'Brien, Caroline C; Lopes, Augusto C; Kolandaivelu, Kumaran; Edelman, Elazer R

    2018-04-11

    Stent thrombosis is a major complication of coronary stent and scaffold intervention. While often unanticipated and lethal, its incidence is low making mechanistic examination difficult through clinical investigation alone. Thus, throughout the technological advancement of these devices, experimental models have been indispensable in furthering our understanding of device safety and efficacy. As we refine model systems to gain deeper insight into adverse events, it is equally important that we continue to refine our measurement methods. We used digital signal processing in an established flow loop model to investigate local flow effects due to geometric stent features and ultimately its relationship to thrombus formation. A new metric of clot distribution on each microCT slice termed normalized clot ratio was defined to quantify this distribution. Three under expanded coronary bare-metal stents were run in a flow loop model to induce clotting. Samples were then scanned in a MicroCT machine and digital signal processing methods applied to analyze geometric stent conformation and spatial clot formation. Results indicated that geometric stent features play a significant role in clotting patterns, specifically at a frequency of 0.6225 Hz corresponding to a geometric distance of 1.606 mm. The magnitude-squared coherence between geometric features and clot distribution was greater than 0.4 in all samples. In stents with poor wall apposition, ranging from 0.27 mm to 0.64 mm maximum malapposition (model of real-world heterogeneity), clots were found to have formed in between stent struts rather than directly adjacent to struts. This early work shows how the combination of tools in the areas of image processing and signal analysis can advance the resolution at which we are able to define thrombotic mechanisms in in vitro models, and ultimately, gain further insight into clinical performance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Configuration affects parallel stent grafting results.

    PubMed

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31.25% of retrograde stents having any complication. Parallel stent grafting offers an off-the-shelf option to treat a variety of aortic diseases. There is an increased risk of parallel stent and overall EVAR compromise with <10% main body oversizing. Thirty-day mortality is increased when more than one parallel stent is placed. Antegrade configurations are preferred to any retrograde configuration, with optimal oversizing >20%. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Stenting or not prior to extracorporeal shockwave lithotripsy for ureteral stones? Results of a prospective randomized study.

    PubMed

    Sfoungaristos, Stavros; Polimeros, Nikolaos; Kavouras, Adamantios; Perimenis, Petros

    2012-06-01

    To determine the need for pre-treatment stenting in patients undergoing extracorporeal shockwave lithotripsy (ESWL) for ureteral stones sized 4-10 mm. A prospective randomized study was conducted between September 2009 and March 2011. Included 156 patients randomized in stented and non-stented groups and underwent a maximum of 3 ESWL sessions. Radiographic follow-up was used to assess the stone fragmentation and clearance. Results were compared in terms of stone-free rates, post-treatment morbidity and complications. Overall efficacy was 76.9%. Stone-free rates were statistically significantly lower (P = 0.026) in the stented group (68.6%) compared to the non-stented ones (83.7%). Furthermore, stenting was significantly correlated with post-treatment lower urinary tract symptoms (P ≤ 0.001), need for more ESWL sessions (P = 0.019) and possibility for operation due to ESWL failure (P = 0.026). A multivariate analysis was conducted to identify the parameters which may predict complete stone removal after ESWL. Stone size (P = 0.026), stone location (P = 0.011) and stenting (P = 0.007) were the most significant factors. ESWL is an efficient and safe treatment for 4- to 10-mm ureteral stones. Pre-treatment stenting is limiting stone-free rates and is significantly influencing post-ESWL morbidity and quality of life in a negative manner, while it contributes minimally to the prophylaxis of complications.

  10. Advances in helical stent design and fabrication thermal treatment and structural interaction studies of the simulated plaque-laden artery

    NASA Astrophysics Data System (ADS)

    Welch, Tre Raymond

    Advancements in processing biomaterials have lead to the development of bioresorbable PLLA drug-loaded stents with different geometric configurations. To further advance the technology, systematic studies have been carried out. This dissertation consists of five specific aims: (1) To characterize the effects of thermal annealing on the mechanical characteristics of PLLA helical stent, (2) To characterize the mechanical characteristics of a PLLA double helix stent, (3) To characterize the physical and chemical properties of PLLA films impregnated with niacin and curcumin, (4) To characterize the mechanical interaction of expanded stent and vascular wall with both model simulation and experimental studies using PDMS phantom arteries, (5) To simulate the stent-plaque-artery interactions using computer models. Results and their significances in bioresorbable PLLA drug-loaded stents technology as well as clinical prospects will be presented. For Aim1, thermal annealing is shown to improve mechanical characteristics of the helical stent, including pressure-diameter response curves, incremental stiffness, and collapse pressure. Differential scanning calorimetric analysis of stent fiber reveals that thermal annealing contribute to increased percent crystallinity, thus enhanced mechanical characteristics of the stent. For Aim 2, the new double helix design was shown to leads to improved mechanical characteristics of stent, including pressure-diameter response curves, incremental stiffness, and collapse pressure. Further, it was found to lead to an increased percent crystallinity and reduced degradation rate. For Aim 3, the changes in mechanical properties, crystallinity in PLLA polymer loaded with curcumin, or niacin, or both from that of control are clearly delineated. Results from Aim 4 shed lights on the mechanical disturbance in the vicinity of deployed stent and vascular wall as well as the abnormal shear stresses on the vascular endothelium. Their implications in triggering thrombi formation are discussed. Results from Aim 5 provided insights on the stent-plaque-artery mechanical interaction and how the altered mechanical environment after stent deployment could affect vascular remodeling and factors lead to re-stenosis. The significances of this work in advancing the bioresorbable PLLA drug-loaded stents technology as well as its clinical prospects are presented.

  11. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    PubMed Central

    van Hamersvelt, R. W.; Budde, R. P. J.; de Jong, P. A.; Schilham, A. M. R.; Bos, C.; Breur, J. M. P. J.; Leiner, T.

    2017-01-01

    Background Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. Purpose To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. Material and methods Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100%) in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis. Results Median stent lumen visibility was 88 (IQR 86–90)% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78–84%) stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07–0.05] mm) and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 –-2.41] mm). Conclusion Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study. PMID:28141852

  12. Complications of stent placement in patients with esophageal cancer: A systematic review and network meta-analysis

    PubMed Central

    Doosti-Irani, Amin; Mansournia, Mohammad Ali; Rahimi-Foroushani, Abbas; Haddad, Peiman

    2017-01-01

    Background Palliative treatments and stents are necessary for relieving dysphagia in patients with esophageal cancer. The aim of this study was to simultaneously compare available treatments in terms of complications. Methods Web of Science, Medline, Scopus, Cochrane Library and Embase were searched. Statistical heterogeneity was assessed using the Chi2 test and was quantified by I2. The results of this study were summarized in terms of Risk Ratio (RR). The random effects model was used to report the results. The rank probability for each treatment was calculated using the p-score. Results Out of 17855 references, 24 RCTs reported complications including treatment related death (TRD), bleeding, stent migration, aspiration, severe pain and fistula formation. In the ranking of treatments, thermal ablative therapy (p-score = 0.82), covered Evolution® stent (p-score = 0.70), brachytherapy (p-score = 0.72) and antireflux stent (p-score = 0.74) were better treatments in the network of TRD. Thermal ablative therapy (p-score = 0.86), the conventional stent (p-score = 0.62), covered Evolution® stent (p-score = 0.96) and brachytherapy (p-score = 0.82) were better treatments in the network of bleeding complications. Covered Evolution® (p-score = 0.78), uncovered (p-score = 0.88) and irradiation stents (p-score = 0.65) were better treatments in network of stent migration complications. In the network of severe pain, Conventional self-expandable nitinol alloy covered stent (p-score = 0.73), polyflex (p-score = 0.79), latex prosthesis (p-score = 0.96) and brachytherapy (p-score = 0.65) were better treatments. Conclusion According to our results, thermal ablative therapy, covered Evolution® stents, brachytherapy, and antireflux stents are associated with a lower risk of TRD. Moreover, thermal ablative therapy, conventional, covered Evolution® and brachytherapy had lower risks of bleeding. Overall, fewer complications were associated with covered Evolution® stent and brachytherapy. PMID:28968416

  13. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    PubMed

    den Harder, A M; Suchá, D; van Hamersvelt, R W; Budde, R P J; de Jong, P A; Schilham, A M R; Bos, C; Breur, J M P J; Leiner, T

    2017-01-01

    Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100%) in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis. Median stent lumen visibility was 88 (IQR 86-90)% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84%) stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm) and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm). Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  14. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

    PubMed

    Kim, Jung-Sun; Ha, Jinyong; Kim, Byeong-Keuk; Shin, Dong-Ho; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2014-06-01

    This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. Tracking the fate of interested regions of struts at different time points has not been investigated. Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus- (n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared. The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001). The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of Dyslipidemia and Hypertension and the Types of Implanted Drug-Eluting Stents; NCT01502904). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. [Effects of control-releasing arsenic trioxide-eluting stent on intimal smooth muscle cells and type III collagen in canine coronary artery post-stent model].

    PubMed

    Zhao, Jun-Li; Sun, Bao-Gui; Wen, Qin-Zhu

    2010-06-01

    To study the safety and efficacy of control-releasing arsenic trioxide (As2O3)-eluting stent on intimal smooth muscle cells (SMC) and type III collagen (CIII) in canine coronary artery post-stent model. Twenty-four experimental canines were equally divided into 4 groups, the three tested groups were deployed by stents with different dosage of As2O3 (1.6 microg/mm2, 2.4 microg/mm2 and 3.2 microg/mm2 in low, median and high dose groups, respectively) and coated with polybutyl methacrylate/nano silica and poly-lactide-coglycolide in mild oversizing (stent/vessel ratio of 1.3:1) in left anterior descending (LAD) or circumflex coronary arteries (LCX), while the control group only by simple coated stent without As2O3. The effect was assessed 4 weeks after stent implantation in terms of vascular histomorphology, and changes of SMC and C III expressions were detected using immunohistochemical analysis. Subintimal hemorrhage, medial/adventitial necrosis, thrombosis and inflammatory cell infiltration were not found and integral endothelium could be seen under screening electron microscopy in all groups. Positive expression of SMC and CIII in the tested groups, especial in the high dose As2O3 group, was more weaker than that in control group. Histo-morphological analysis showed that the neo-genetic intimal area and vascular stenosis were lower, but the mean luminal diameter was larger in the three tested groups than that in the control group (P < 0.01). Comparisons of various indices between tested groups treated by different doses of As2O3 showed that the difference between high/median dose vs. low dose was significant (P < 0.01), but that between high dose vs. median dose was insignificant (P > 0.05). Control-releasing As2O3-eluting stent shows a reliable and safe effect in preventing and treating post-stent restenosis by its dose-dependent inhibition on expressions of SMC and CIII to suppress the neo-genesis of intimal hyperplasia.

  17. Short-term outcome after stenting versus endarterectomy for symptomatic carotid stenosis: a preplanned meta-analysis of individual patient data.

    PubMed

    Bonati, Leo H; Dobson, Joanna; Algra, Ale; Branchereau, Alain; Chatellier, Gilles; Fraedrich, Gustav; Mali, Willem P; Zeumer, Hermann; Brown, Martin M; Mas, Jean-Louis; Ringleb, Peter A

    2010-09-25

    Results from randomised controlled trials have shown a higher short-term risk of stroke associated with carotid stenting than with carotid endarterectomy for the treatment of symptomatic carotid stenosis. However, these trials were underpowered for investigation of whether carotid artery stenting might be a safe alternative to endarterectomy in specific patient subgroups. We therefore did a preplanned meta-analysis of individual patient data from three randomised controlled trials. Data from all 3433 patients with symptomatic carotid stenosis who were randomly assigned and analysed in the Endarterectomy versus Angioplasty in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S) trial, the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) trial, and the International Carotid Stenting Study (ICSS) were pooled and analysed with fixed-effect binomial regression models adjusted for source trial. The primary outcome event was any stroke or death. The intention-to-treat (ITT) analysis included all patients and outcome events occurring between randomisation and 120 days thereafter. The per-protocol (PP) analysis was restricted to patients receiving the allocated treatment and events occurring within 30 days after treatment. In the first 120 days after randomisation (ITT analysis), any stroke or death occurred significantly more often in the carotid stenting group (153 [8·9%] of 1725) than in the carotid endarterectomy group (99 [5·8%] of 1708, risk ratio [RR] 1·53, [95% CI 1·20-1·95], p=0·0006; absolute risk difference 3·2 [1·4-4·9]). Of all subgroup variables assessed, only age significantly modified the treatment effect: in patients younger than 70 years (median age), the estimated 120-day risk of stroke or death was 50 (5·8%) of 869 patients in the carotid stenting group and 48 (5·7%) of 843 in the carotid endarterectomy group (RR 1·00 [0·68-1·47]); in patients 70 years or older, the estimated risk with carotid stenting was twice that with carotid endarterectomy (103 [12·0%] of 856 vs 51 [5·9%] of 865, 2·04 [1·48-2·82], interaction p=0·0053, p=0·0014 for trend). In the PP analysis, risk estimates of stroke or death within 30 days of treatment among patients younger than 70 years were 43 (5·1%) of 851 patients in the stenting group and 37 (4·5%) of 821 in the endarterectomy group (1·11 [0·73-1·71]); in patients 70 years or older, the estimates were 87 (10·5%) of 828 patients and 36 (4·4%) of 824, respectively (2·41 [1·65-3·51]; categorical interaction p=0·0078, trend interaction p=0·0013]. Stenting for symptomatic carotid stenosis should be avoided in older patients (age ≥70 years), but might be as safe as endarterectomy in younger patients. The Stroke Association. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. 76 FR 14568 - Federal Acquisition Regulation; Use of Commercial Services Item Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-16

    ...-AL44 Federal Acquisition Regulation; Use of Commercial Services Item Authority AGENCIES: Department of... interim rule amending the Federal Acquisition Regulation (FAR) to implement section 868 of the Duncan... interim rule. II. Discussion/Analysis The analysis of public comments by the Defense Acquisition...

  19. Tracheal Wall Thickening Is Associated with the Granulation Tissue Formation Around Silicone Stents in Patients with Post-Tuberculosis Tracheal Stenosis

    PubMed Central

    Eom, Jung Seop; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung

    2013-01-01

    Purpose Tracheal restenosis due to excessive granulation tissue around a silicone stent requires repeated bronchoscopic interventions in patients with post-tuberculosis tracheal stenosis (PTTS). The current study was conducted to identify the risk factors for granulation tissue formation after silicone stenting in PTTS patients. Materials and Methods A retrospective study was conducted between January 1998 and December 2010. Forty-two PTTS patients with silicone stenting were selected. Clinical and radiological variables were retrospectively collected and analyzed. Results Tracheal restenosis due to granulation tissue formation were found in 20 patients (47.6%), and repeated bronchoscopic interventions were conducted. In multivariate analysis, tracheal wall thickness, measured on axial computed tomography scan, was independently associated with granulation tissue formation after silicone stenting. Furthermore, the degree of tracheal wall thickness was well correlated with the degree of granulation tissue formation. Conclusion Tracheal wall thickening was associated with granulation tissue formation around silicone stents in patients with post-tuberculosis tracheal stenosis. PMID:23709431

  20. Tracheal wall thickening is associated with the granulation tissue formation around silicone stents in patients with post-tuberculosis tracheal stenosis.

    PubMed

    Eom, Jung Seop; Kim, Hojoong; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung

    2013-07-01

    Tracheal restenosis due to excessive granulation tissue around a silicone stent requires repeated bronchoscopic interventions in patients with post-tuberculosis tracheal stenosis (PTTS). The current study was conducted to identify the risk factors for granulation tissue formation after silicone stenting in PTTS patients. A retrospective study was conducted between January 1998 and December 2010. Forty-two PTTS patients with silicone stenting were selected. Clinical and radiological variables were retrospectively collected and analyzed. Tracheal restenosis due to granulation tissue formation were found in 20 patients (47.6%), and repeated bronchoscopic interventions were conducted. In multivariate analysis, tracheal wall thickness, measured on axial computed tomography scan, was independently associated with granulation tissue formation after silicone stenting. Furthermore, the degree of tracheal wall thickness was well correlated with the degree of granulation tissue formation. Tracheal wall thickening was associated with granulation tissue formation around silicone stents in patients with post-tuberculosis tracheal stenosis.

  1. Single brand, fully-covered, self-expandable metal stent for the treatment of benign biliary disease: when should stents be removed?

    PubMed

    Mangiavillano, Benedetto; Khashab, Mouen A; Eusebi, Leonardo H; Tarantino, Ilaria; Bianchetti, Mario; Semeraro, Rossella; Pellicano, Rinaldo; Traina, Mario; Repici, Alessandro

    2018-05-31

    The two most relevant endoscopic treatable benign biliary diseases (BBD) are benign biliary strictures (BBSs) and biliary leaks (BLs), often associated with high morbidity. The most common endoscopic treatment for biliary strictures involves placement of multiple plastic stents (PSs), with or without balloon dilation, followed by planned exchange of the stents. Thus, there continues to be high interest in pursuing alternative endoscopic approaches that may achieve better results with fewer interventions. In this setting, the use of a fully-covered, self-expandable metal stent (FCSEMS) is an attractive alternative to single or multiple PSs for the treatment of BBDs. A single metal stent can remain in place for a longer period of time before removal; however, the maximum time the stent can be remain in place is still not well defined. The aim of this review is to determine the removal time of the TaeWoong® FCSEMS, placed for BBD. According to our data analysis, considering the absence of loss of the covering of the FCSEMS and of any adverse events during and after stent removal, leaving the TaeWoong medical FCSEMS in situ for an 8 months' period seems to be acceptable for benign biliary diseases. Further studies need to evaluate their removability at 1 year.

  2. Numerical analysis of urine flow through the side holes of a double J stent in a ureteral stenosis.

    PubMed

    Kim, Hyoung-Ho; Choi, Young Ho; Lee, Seung Bae; Baba, Yasutaka; Kim, Kyung-Wuk; Suh, Sang-Ho

    2017-07-20

    Ureteral stenosis presents with a narrowing in the ureter, due to an intrinsic or extrinsic ureteral disease, such as ureter cancer or retroperitoneal fibrosis. The placement of a double J stent in the upper urinary system is one of the most common treatments of ureteral stenosis, along with the insertion of a percutaneous nephrostomy tube into the renal pelvis. The effect that the side holes in a double J stent have on urine flow has been evaluated in a few studies using straight ureter models. In this study, urine flow through a double J stent's side holes was analyzed in curved ureter models, which were based on human anatomy. In ureteral stenosis, especially in severe ureteral stenosis, a stent with side holes had a positive effect on the luminal and total flow rates, compared with the rates for a stent without side holes. The more side holes a stent has, the greater the luminal and total flow rates. However, the angular positions of the side holes did not affect flow rate. In conclusion, the side holes in a double J stent had a positive effect on ureteral stenosis, and the effect became greater as the ureteral stenosis became more severe.

  3. Computational hemodynamics of an implanted coronary stent based on three-dimensional cine angiography reconstruction.

    PubMed

    Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C

    2005-01-01

    Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.

  4. Long term follow-up of bifurcation aneurysms treated with braided stent assisted coiling and complex T- and Y- stent constructs.

    PubMed

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew; Wenderoth, Jason D

    2018-06-01

    Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Bare-metal stents across the Vater's ampulla is a safe method for patients with lower bile duct obstruction

    PubMed Central

    Mao, Xiao-Nan; Lu, Zai-Ming; Wen, Feng; Liang, Hong-Yuan; Guo, Qi-Yong

    2017-01-01

    Abstract This study explored the effect of the implant position of stents across the Vater's ampulla on treatment outcomes in patients with lower bile duct obstruction. In the retrospective study, 41 patients with malignant obstruction of the lower bile duct and obstructive jaundice received percutaneous transhepatic biliary placement of bare-metal stents. Basic demographic data on patients, such as sex, age, and primary diseases, and follow-up data, including postoperative complications and jaundice-free survival, were recorded. The follow-up data on patients with an involved ampulla, patients with an uninvolved ampulla, patients with a stent across the ampulla, and patients with a stent at a site other than the ampulla were compared. Furthermore, prognostic factors for jaundice- free survival were investigated using Cox proportional hazards regression analysis. Among the 41 patients, 38 patients experienced subsiding of jaundice, whereas 3 cases had unsuccessful stent patency. Whether or not the ampulla was involved did not influence the incidence rates of postoperative complications and the jaundice-free survival time. Notably, when stents were placed across the ampulla, the jaundice-free survival time was significantly longer than when stents were placed at sites other than across the ampulla (P < .05). Furthermore, placement of the stent across the ampulla or at other sites was an independent prognostic factor (hazard ratio = 0.154, 95% confidence interval 0.042–0.560, P = .005) for jaundice-free survival of patients. The current study revealed that the implant position of a stent across the ampulla resulted in maintenance of stent patency and prolongation of the jaundice-free survival time. PMID:29137005

  6. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    PubMed

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  7. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    PubMed

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  8. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography

    PubMed Central

    Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870

  9. Computed tomography coronary stent imaging with iterative reconstruction: a trade-off study between medium kernel and sharp kernel.

    PubMed

    Zhou, Qijing; Jiang, Biao; Dong, Fei; Huang, Peiyu; Liu, Hongtao; Zhang, Minming

    2014-01-01

    To evaluate the improvement of iterative reconstruction in image space (IRIS) technique in computed tomographic (CT) coronary stent imaging with sharp kernel, and to make a trade-off analysis. Fifty-six patients with 105 stents were examined by 128-slice dual-source CT coronary angiography (CTCA). Images were reconstructed using standard filtered back projection (FBP) and IRIS with both medium kernel and sharp kernel applied. Image noise and the stent diameter were investigated. Image noise was measured both in background vessel and in-stent lumen as objective image evaluation. Image noise score and stent score were performed as subjective image evaluation. The CTCA images reconstructed with IRIS were associated with significant noise reduction compared to that of CTCA images reconstructed using FBP technique in both of background vessel and in-stent lumen (the background noise decreased by approximately 25.4% ± 8.2% in medium kernel (P

  10. Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses.

    PubMed

    Chiastra, Claudio; Wu, Wei; Dickerhoff, Benjamin; Aleiou, Ali; Dubini, Gabriele; Otake, Hiromasa; Migliavacca, Francesco; LaDisa, John F

    2016-07-26

    The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual's anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis. Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and composition were estimated from OCT and assigned to models, and structural simulations were performed in Abaqus. Artery geometries after virtual stent expansion of Xience Prime or Nobori stents created in SolidWorks were compared to post-operative geometry from OCT and CT before being extracted and used for CFD simulations in SimVascular. Inflow boundary conditions based on body surface area, and downstream vascular resistances and capacitances were applied at branches to mimic physiology. Artery geometries obtained after virtual expansion were in good agreement with those reconstructed from patient images. Quantitative comparison of the distance between reconstructed and post-stent geometries revealed a maximum difference in area of 20.4%. Adverse indices of wall shear stress were more pronounced for thicker Nobori stents in both patients. These findings verify structural analyses of stent expansion, introduce a workflow to combine software packages for solid and fluid mechanics analysis, and underscore important stent design features from prior idealized studies. The proposed approach may ultimately be useful in determining an optimal choice of stent and position for each patient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    PubMed

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  12. Stage of hilar cholangiocarcinoma predicts recurrence of biliary obstruction in patients with metal stents.

    PubMed

    Siddiqui, Ali; Shahid, Haroon; Sarkar, Avik; Cox, Kristen; Kowalski, Thomas E; Loren, David E; Sharma, Ashish; Laing, Patrick; Birch, Madeline; Adler, Douglas G

    2013-09-01

    Most patients with hilar cholangiocarcinomas present with unresectable tumors, so only palliative biliary drainage with self-expanding metal stents (SEMS) is possible. Stents eventually cease to function because of tumor overgrowth and/or other causes, so it is important to identify factors that affect stent patency and failure. We examined the patency of endoscopically placed SEMS in patients with hilar cholangiocarcinoma and factors associated with patency. We performed a retrospective study of 120 consecutive patients (mean age, 67 ± 14.6 years; 74 male) who presented with obstructive jaundice from hilar cholangiocarcinoma and underwent bilateral SEMS from September 2006 through April 2012 at 2 US tertiary medical centers. We collected data on patient demographics and survival, success of stent placement and function, and immediate adverse events. The primary outcome was duration of stent patency (time from insertion to failure). Thirty-eight patients had stage 1 hilar cholangiocarcinomas, 45 had stage 2, 12 had stage 3, and 25 had stage 4. The median length of the hilar stricture was 9 mm (range, 8-50 mm). The stent was successfully passaged across the stricture in all patients and was functional in 115; its median length was 8 mm (range, 8-10 mm), and diameter was 80 mm (range, 60-100 mm). Fourteen patients had immediate adverse events, including perforation (n = 2), bleeding (n = 2), pancreatitis (n = 9), and cholangitis (n = 1). Median survival was 17 weeks (range, 1-211 weeks), and 50 patients had stent occlusion. On Kaplan-Meier analysis, the median time from stent placement to occlusion was 17 weeks (range, 1-104 weeks). More patients with stage 3 or 4 tumors (64%) had SEMS occlusion than patients with stage 1 or 2 tumors (28%) in univariate analysis (P = .017). In multivariate analysis, only cancer stage was independently and significantly associated with patency (P = .006; hazard ratio, 2.77); age, sex, length of stricture, and SEMS diameter and length were not. The cumulative patency of bilateral SEMS for hilar cholangiocarcinoma significantly decreases as tumor stage increases. Age, sex, length of stricture, and SEMS diameter and length are not associated with SEMS patency. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  13. Comparison of nitinol urethral stent infections with indwelling catheter-associated urinary-tract infections.

    PubMed

    Egilmez, Tulga; Aridogan, I Atilla; Yachia, Daniel; Hassin, David

    2006-04-01

    To determine the efficacy of intraurethral metal stents in preventing or eradicating urinary-tract infections (UTI) during the management of bladder outlet obstruction (BOO) by comparing the frequency and nature of the infections with indwelling-catheter-associated UTI. The SAS relative-risk test was used to compare the risks of UTI in 76 patients with temporary urethral stents, 60 patients with BOO who had never been catheterized nor stented, and 34 patients with a permanent indwelling urethral catheter (PIUC). Infection was assessed 1 month after placement of the devices. Scanning electron microscopy (SEM) of the proximal and distal pieces of the stents removed from five patients with and five patients without UTI was carried out in a search for predisposing changes on the surfaces. After insertion of the catheter, UTI developed in 79.4% of the patients who originally had sterile urine. However, after insertion of the stent, UTI developed in only 40.9% of the patients with sterile urine. In 21 (44.6%) of the catheterized patients who had infected urine, UTI was eradicated after stent insertion. The SEM analysis of the stents showed that a thick organic layer had formed only on the infected devices but with no sign of erosion. Urinary infection is a significant problem in patients with PIUC but is significantly less frequent and less severe in patients with urethral stents. This advantage of stents over the conventional urethral catheter, in addition to their obvious convenience for the patient, make them good alternatives to reduce the risk of UTI.

  14. Palliation of Malignant Biliary and Duodenal Obstruction with Combined Metallic Stenting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akinci, Devrim, E-mail: akincid@hotmail.com; Akhan, Okan; Ozkan, Fuat

    2007-11-15

    Purpose. The purpose of this study is to evaluate the efficacy of palliation of malignant biliary and duodenal obstruction with combined metallic stenting under fluoroscopy guidance. Materials and Methods. A retrospective analysis of 9 patients (6 men and 3 women) who underwent biliary and duodenal stenting was performed. The mean age of patients was 61 years (range: 42-80 years). The causes of obstruction were pancreatic carcinoma in 7 patients, cholangiocellular carcinoma in one, and duodenal carcinoma in the other. Biliary and duodenal stents were placed simultaneously in 4 patients. In other 5 patients dudodenal stents were placed after biliary stentingmore » when the duodenal obstruction symptoms have developed. In two patients duodenal stents were advanced via transgastric approach. Results. Technical success rate was 100 %. After percutaneous biliary drainage and stenting bilirubin levels decreased to normal levels in 6 patients and in remaining 3 patients mean reduction of 71% in bilirubin levels was achieved. Tumoral ingrowth occurred in one patient and percutaneous biliary restenting was performed 90 days after the initial procedure. Of the 9 patients, 6 patients were able to tolerate solid diet, whereas 2 patients could tolerate liquid diet and one patient did not show any improvement. Mean survival periods were 111 and 73 days after biliary and duodenal stenting, respectively. Conclusion. Combined biliary and duodenal stent placement which can be performed under fluoroscopic guidance without assistance of endoscopy is feasible and an effective method of palliation of malignant biliary and duodenal obstructions. If transoral and endoscopic approaches fail, percutaneous gastrostomy route allows duodenal stenting.« less

  15. Semi-Automatic Electronic Stent Register: a novel approach to preventing ureteric stents lost to follow up.

    PubMed

    Macneil, James W H; Michail, Peter; Patel, Manish I; Ashbourne, Julie; Bariol, Simon V; Ende, David A; Hossack, Tania A; Lau, Howard; Wang, Audrey C; Brooks, Andrew J

    2017-10-01

    Ureteric stents are indispensable tools in modern urology; however, the risk of them not being followed-up once inserted poses medical and medico-legal risks. Stent registers are a common solution to mitigate this risk; however, manual registers are logistically challenging, especially for busy units. Western Sydney Local Health District developed a novel Semi-Automatic Electronic Stent Register (SAESR) utilizing billing information to track stent insertions. To determine the utility of this system, an audit was conducted comparing the 6 months before the introduction of the register to the first 6 months of the register. In the first 6 months of the register, 457 stents were inserted. At the time of writing, two of these are severely delayed for removal, representing a rate of 0.4%. In the 6 months immediately preceding the introduction of the register, 497 stents were inserted, and six were either missed completely or severely delayed in their removal, representing a rate of 1.2%. A non-inferiority analysis found this to be no worse than the results achieved before the introduction of the register. The SAESR allowed us to improve upon our better than expected rate of stents lost to follow up or severely delayed. We demonstrated non-inferiority in the rate of lost or severely delayed stents, and a number of other advantages including savings in personnel costs. The semi-automatic register represents an effective way of reducing the risk associated with a common urological procedure. We believe that this methodology could be implemented elsewhere. © 2017 Royal Australasian College of Surgeons.

  16. Incidence of urinary extravasation and rate of ureteral stenting after high-grade renal trauma in adults: a meta-analysis

    PubMed Central

    Anderson, Ross E.; Fiander, Michelle; McFarland, Mary M.; Stoddard, Gregory J.; Hotaling, James M.; Myers, Jeremy B.

    2018-01-01

    Background Collecting system injury and urinary extravasation is an important yet understudied aspect of renal trauma. We aimed to examine the incidence of urinary extravasation and also the rates of ureteral stenting after high-grade renal trauma (HGRT) in adults. Methods A search strategy was developed to search Ovid Medline, Embase, CINAHL, and Cochrane Library. Two reviewers screened titles and abstracts, followed by full-text review of the relevant publications. Studies were included if they indicated the number of patients with HGRT [the American Association for the Surgery of Trauma (AAST) grades III–IV or equivalents] and number of patients with urinary extravasation. A descriptive meta-analysis of binary proportions was performed with random-effects model to calculate the incidence of urinary extravasation and rates of ureteral stenting. Results After screening, 24 and 20 studies were included for calculating urinary extravasation and stenting rates, respectively. Most studies involved blunt injury and were retrospective single-center case series. Incidence of urinary extravasation was 29% (95% CI: 17–42%) after HGRT (grade III–V), and 51% (95% CI: 38–64%) when only grade IV–V injuries were combined. Overall, 29% (95% CI: 22–36%) of patients with urinary extravasation underwent ureteral stenting. Conclusions Approximately 30% of patients with HGRT are diagnosed with urinary extravasation and 29% of those with urinary extravasation undergo ureteral stenting. Understanding the rate of urinary extravasation and interventions is the first step in creating a prospective trial designed to demonstrate when ureteral stenting and aggressive management of urinary extravasation is needed. PMID:29928614

  17. Incidence of urinary extravasation and rate of ureteral stenting after high-grade renal trauma in adults: a meta-analysis.

    PubMed

    Keihani, Sorena; Anderson, Ross E; Fiander, Michelle; McFarland, Mary M; Stoddard, Gregory J; Hotaling, James M; Myers, Jeremy B

    2018-05-01

    Collecting system injury and urinary extravasation is an important yet understudied aspect of renal trauma. We aimed to examine the incidence of urinary extravasation and also the rates of ureteral stenting after high-grade renal trauma (HGRT) in adults. A search strategy was developed to search Ovid Medline, Embase, CINAHL, and Cochrane Library. Two reviewers screened titles and abstracts, followed by full-text review of the relevant publications. Studies were included if they indicated the number of patients with HGRT [the American Association for the Surgery of Trauma (AAST) grades III-IV or equivalents] and number of patients with urinary extravasation. A descriptive meta-analysis of binary proportions was performed with random-effects model to calculate the incidence of urinary extravasation and rates of ureteral stenting. After screening, 24 and 20 studies were included for calculating urinary extravasation and stenting rates, respectively. Most studies involved blunt injury and were retrospective single-center case series. Incidence of urinary extravasation was 29% (95% CI: 17-42%) after HGRT (grade III-V), and 51% (95% CI: 38-64%) when only grade IV-V injuries were combined. Overall, 29% (95% CI: 22-36%) of patients with urinary extravasation underwent ureteral stenting. Approximately 30% of patients with HGRT are diagnosed with urinary extravasation and 29% of those with urinary extravasation undergo ureteral stenting. Understanding the rate of urinary extravasation and interventions is the first step in creating a prospective trial designed to demonstrate when ureteral stenting and aggressive management of urinary extravasation is needed.

  18. Interim Terrain Data (ITD) and Vector Product Interim Terrain Data (VITD) user's guide

    DOT National Transportation Integrated Search

    1996-09-01

    This guide is intended to be a convenient reference for users of these types of terrain analysis data. ITD is a digitized version of the standard 1:50,000-scale tactical terrain analysis data base (TTADB) product produced by the Defense Mapping Agenc...

  19. Endoscopic bilio-duodenal bypass: outcomes of primary and revision efficacy of combined metallic stents in malignant duodenal and biliary obstructions.

    PubMed

    Canena, Jorge; Coimbra, João; Carvalho, Diana; Rodrigues, Catarina; Silva, Mário; Costa, Mariana; Horta, David; Mateus Dias, António; Seves, Isabel; Ramos, Gonçalo; Ricardo, Leonel; Coutinho, António Pereira; Romão, Carlos; Veiga, Pedro Mota

    2014-11-01

    Self-expandable metal stents (SEMSs) can be used for palliation of combined malignant biliary and duodenal obstructions. However, the results of the concomitant stent placement for the duration of the patients' lives, as well as the need for and efficacy of endoscopic revision, are unclear. This study evaluated the clinical effectiveness of SEMS placement for combined biliary and duodenal obstructions throughout the patients' lives and the need for endoscopic revision. This study is a retrospective multicenter study of 50 consecutive patients who underwent simultaneous or sequential SEMS placement for malignant biliary and duodenal obstructions. The data were collected to analyze the sustained relief of obstructive symptoms until the patients' death and the efficacy of endoscopic revision, as well as stent patency, adverse events, survival and prognostic factors for stent patency. Technical and immediate clinical success was achieved in all of the patients. Duodenal stricture occurred before the papilla in 35 patients (70 %), involved the papilla in 11 patients (22 %) and was observed distal to the papilla in four patients (8 %). Initial biliary stenting was performed endoscopically in 42 patients (84 %) and percutaneously in eight patients. After combined stenting, 30 patients (60 %) required no additional intervention until the time of their death. The remaining 20 patients were successfully treated using endoscopic stent reinsertion: nine patients needed biliary revision, three patients needed duodenal restenting and eight patients needed both biliary and duodenal reinsertion. The median duodenal stent patency and median biliary stent patency were 34 and 27 weeks, respectively. The median survival after combined stent placement was 18 weeks. A Cox multivariate analysis showed that duodenal stent obstruction after combined stenting was a risk factor for biliary stent obstruction (hazard ratio 6.85; 95 % confidence interval 1.43-198.98; P = 0.025). Endoscopic bilio-duodenal bypass is clinically effective, and the majority of the patients need no additional intervention until their death. Endoscopic revision is feasible and has a high success rate.

  20. Risk Factors of Subacute Thrombosis After Intracranial Stenting for Symptomatic Intracranial Arterial Stenosis.

    PubMed

    Sun, Xuan; Tong, Xu; Lo, Wai Ting; Mo, Dapeng; Gao, Feng; Ma, Ning; Wang, Bo; Miao, Zhongrong

    2017-03-01

    We aimed to explore the risk factors of subacute thrombosis (SAT) after intracranial stenting for patients with symptomatic intracranial arterial stenosis. From January to December 2013, all symptomatic intracranial arterial stenosis patients who underwent intracranial stenting in Beijing Tiantan Hospital were prospectively registered into this study. Baseline clinical features and operative data were compared in patients who developed SAT with those who did not. Binary logistic regression model was used to determine the risk factors associated with SAT. Of the 221 patients enrolled, 9 (4.1%) cases had SAT 2 to 8 days after stenting. Binary logistic analysis showed that SAT was related with tandem stenting (odds ratio [OR], 11.278; 95% confidence interval [CI], 2.422-52.519) and antiplatelet resistance (aspirin resistance: OR, 6.267; 95% CI, 1.574-24.952; clopidogrel resistance: OR, 15.526; 95% CI, 3.105-77.626; aspirin and clopidogrel resistance: OR, 12.246; 95% CI, 2.932-51.147; and aspirin or clopidogrel resistance: OR, 11.340; 95% CI, 2.282-56.344). Tandem stenting and antiplatelet resistance might contribute to the development of SAT after intracranial stenting in patients with symptomatic intracranial arterial stenosis. © 2017 American Heart Association, Inc.

  1. In-situ investigation of stress conditions during expansion of bare metal stents and PLLA-coated stents using the XRD sin(2)ψ-technique.

    PubMed

    Kowalski, Wolfgang; Dammer, Markus; Bakczewitz, Frank; Schmitz, Klaus-Peter; Grabow, Niels; Kessler, Olaf

    2015-09-01

    Drug eluting stents (DES) consist of platform, coating and drug. The platform often is a balloon-expandable bare metal stent made of the CoCr alloy L-605 or stainless steel 316 L. The function of the coating, typically a permanent polymer, is to hold and release the drug, which should improve therapeutic outcome. Before implantation, DES are compressed (crimped) to allow implantation in the human body. During implantation, DES are expanded by balloon inflation. Crimping, as well as expansion, causes high stresses and high strains locally in the DES struts, as well as in the polymer coating. These stresses and strains are important design criteria of DES. Usually, they are calculated numerically by finite element analysis (FEA), but experimental results for validation are hardly available. In this work, the X-ray diffraction (XRD) sin(2)ψ-technique is applied to in-situ determination of stress conditions of bare metal L-605 stents, and Poly-(L-lactide) (PLLA) coated stents. This provides a realistic characterization of the near-surface stress state and a validation option of the numerical FEA. XRD-results from terminal stent struts of the bare metal stent show an increasing compressive load stress in tangential direction with increasing stent expansion. These findings correlate with numerical FEA results. The PLLA-coating also bears increasing compressive load stress during expansion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: a randomized prospective study.

    PubMed

    Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon

    2014-07-01

    A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    PubMed Central

    2012-01-01

    Background Refractory benign esophageal strictures (RBESs) have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs), biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs), for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10), biodegradable stents (n = 10) or FCSEMSs (12 weeks, n = 10). Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60%) in the SEPS group, 2 (20%) in the biodegradable group and 3 (30%) in the FCSEMS group (P = 0.16). A total of 8/30 patients (26.6%) were dysphagia-free after the end of follow-up: 1 (10%) in the SEPS group, 3 (30%) in the biodegradable group and 4 (40%) in the FCSEMS group (P = 0.27). More reinterventions were required in the SEPS group (n = 24) than in the biodegradable group (n = 13) or the FCSEMS group (n = 13) (P = 0.24). Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011). Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence. PMID:22691296

  4. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    PubMed

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p < 0.001) and stent use for palliation (78.6% vs 56.3%; p < 0.001). Multivariate analysis indicated obstruction attributed to extracolonic malignancy and covered stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http://links.lww.com/DCR/A417.

  5. Fully-covered metal stents with endoscopic suturing vs. partially-covered metal stents for benign upper gastrointestinal diseases: a comparative study

    PubMed Central

    Ngamruengphong, Saowanee; Sharaiha, Reem; Sethi, Amrita; Siddiqui, Ali; DiMaio, Christopher J.; Gonzalez, Susana; Rogart, Jason; Jagroop, Sophia; Widmer, Jessica; Im, Jennifer; Hasan, Raza Abbas; Laique, Sobia; Gonda, Tamas; Poneros, John; Desai, Amit; Wong, Katherine; Villgran, Vipin; Brewer Gutierrez, Olaya; Bukhari, Majidah; Chen, Yen-I; Hernaez, Ruben; Hanada, Yuri; Sanaei, Omid; Agarwal, Amol; Kalloo, Anthony N.; Kumbhari, Vivek; Singh, Vikesh; Khashab, Mouen A.

    2018-01-01

    Background and study aims  Self-expandable metallic stents (SEMS) have been increasingly used in benign conditions (e. g. strictures, fistulas, leaks, and perforations). Fully covered SEMS (FSEMS) were introduced to avoid undesirable consequences of partially covered SEMS (PSEMS), but come with higher risk of stent migration. Endoscopic suturing (ES) for stent fixation has been shown to reduce migration of FSEMS. Our aim was to compare the outcomes of FSEMS with ES (FS/ES) versus PSEMS in patients with benign upper gastrointestinal conditions. Patients and methods  We retrospectively identified all patients who underwent stent placement for benign gastrointestinal conditions at seven US tertiary-care centers. Patients were divided into two groups: FSEMS with ES (FS/ES group) and PSEMS (PSEMS group). Clinical outcomes between the two groups were compared. Results  A total of 74 (FS/ES 46, PSEMS 28) patients were included. On multivariable analysis, there was no significant difference in rate of stent migration between FS/ES (43 %) and PSEMS (15 %) (adjusted odds ratio 0.56; 95 % CI 0.15 – 2.00). Clinical success was similar [68 % vs. 64 %; P  = 0.81]. Rate of adverse events (AEs) was higher in PSEMS group [13 (46 %) vs. 10 (21 %); P  = 0.03). Difficult stent removal was higher in the PSEMS group (n = 5;17 %) vs. 0 % in the FS/ES group; P  = 0.005. Conclusions  The proportion of stent migration of FS/ES and PSEMS are similar. Rates of other stent-related AEs were higher in the PSEMS group. PSEMS was associated with tissue ingrowth or overgrowth leading to difficult stent removal, and secondary stricture formation. Thus, FSEMS with ES for stent fixation may be the preferred modality over PSEMS for the treatment of benign upper gastrointestinal conditions. PMID:29404384

  6. Factors associated with post-ERCP pancreatitis and the effect of pancreatic duct stenting in a pediatric population.

    PubMed

    Troendle, David M; Abraham, Omana; Huang, Rong; Barth, Bradley A

    2015-01-01

    Risk factors for the development of post-ERCP pancreatitis (PEP) have not been identified in the pediatric population. It remains unclear what constitutes appropriate prophylaxis in this patient population. To assess the prevalence and severity of PEP in the pediatric population and identify factors associated with developing PEP and to evaluate the effect of prophylactic pancreatic duct stenting in high-risk patients. Retrospective analysis of an ERCP database at a single large pediatric center. Academic center. A total of 432 ERCPs performed on 313 patients younger than 19 years of age from January 2004 to October 2013. ERCP for any indication. Rates and severity of PEP, preprocedural and procedural risk factors for the development of PEP, and the effect of pancreatic stents on preventing PEP in high-risk patients. PEP occurred after 47 procedures (prevalence, 10.9%). Thirty-four cases were mild, 9 were moderate, and 4 were severe. There was no mortality. On multiple logistic analysis, pancreatic duct injection (P<.0001; odds ratio 30.8; 95% confidence interval [CI], 9.1-103.9) and pancreatic sphincterotomy (P<.01; OR 3.8; 95% CI, 1.6-9.8) were positively associated with PEP. A history of chronic pancreatitis was negatively associated with PEP (P<.05; OR 0.37; 95% CI, 0.15-0.93). On subset analysis, placing a prophylactic pancreatic stent was associated with significantly increased rates of PEP in patients with pancreatic duct injection compared with those who had no attempt at stent placement (P<.01). Two patients with severe pancreatitis had prophylactic pancreatic stents in place. Retrospective investigation. In the pediatric population, pancreatic duct injection and pancreatic sphincterotomy are associated with significantly increased rates of PEP, whereas a history of chronic pancreatitis is negatively associated. Prophylactic pancreatic stenting is associated with higher rates of PEP in high-risk patients and does not eliminate severe PEP. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.

    PubMed

    LaDisa, John F; Olson, Lars E; Douglas, Hettrick A; Warltier, David C; Kersten, Judy R; Pagel, Paul S

    2006-06-16

    The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation. In the current investigation, we tested the hypothesis that acute changes in stent-induced regional geometry influence distributions of WSS using 3D coronary artery CFD models implanted with stents that either conformed to or caused straightening of the primary curvature of the left anterior descending coronary artery. WSS obtained at several intervals during the cardiac cycle, time averaged WSS, and WSS gradients were calculated using conventional techniques. Implantation of a stent that causes straightening, rather than conforms to the natural curvature of the artery causes a reduction in the radius of curvature and subsequent increase in the Dean number within the stented region. This straightening leads to modest skewing of the velocity profile at the inlet and outlet of the stented region where alterations in indices of WSS are most pronounced. For example, time-averaged WSS in the proximal portion of the stent ranged from 8.91 to 11.7 dynes/cm2 along the pericardial luminal surface and 4.26 to 4.88 dynes/cm2 along the myocardial luminal surface of curved coronary arteries as compared to 8.31 dynes/cm2 observed throughout the stented region of a straight vessel implanted with an equivalent stent. The current results predicting large spatial and temporal variations in WSS at specific locations in curved arterial 3D CFD simulations are consistent with clinically observed sites of restenosis. If the findings of this idealized study translate to the clinical situation, the regional geometry established immediately after stent implantation may predispose portions of the stented vessel to a higher risk of neointimal hyperplasia and subsequent restenosis.

  8. External adjustment sensitivity analysis for unmeasured confounding: an application to coronary stent outcomes, Pennsylvania 2004-2008.

    PubMed

    Huesch, Marco D

    2013-06-01

    Assessing the real-world comparative effectiveness of common interventions is challenged by unmeasured confounding. To determine whether the mortality benefit shown for drug-eluting stents (DES) over bare metal stents (BMS) in observational studies persists after controls for/tests for confounding. Retrospective observational study involving 38,019 patients, 65 years or older admitted for an index percutaneous coronary intervention receiving DES or BMS in Pennsylvania in 2004-2005 followed up for death through 3 years. Analysis was at the patient level. Mortality was analyzed with Cox proportional hazards models allowing for stratification by disease severity or DES use propensity, accounting for clustering of patients. Instrumental variables analysis used lagged physician stent usage to proxy for the focal stent type decision. A method originating in work by Cornfield and others in 1954 and popularized by Greenland in 1996 was used to assess robustness to confounding. DES was associated with a significantly lower adjusted risk of death at 3 years in Cox and in instrumented analyses. An implausibly strong hypothetical unobserved confounder would be required to fully explain these results. Confounding by indication can bias observational studies. No strong evidence of such selection biases was found in the reduced risk of death among elderly patients receiving DES instead of BMS in a Pennsylvanian state-wide population. © Health Research and Educational Trust.

  9. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A; Quiles, Katherine G; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2018-01-01

    The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis.

  10. A Zr-based bulk metallic glass for future stent applications: Materials properties, finite element modeling, and in vitro human vascular cell response.

    PubMed

    Huang, Lu; Pu, Chao; Fisher, Richard K; Mountain, Deidra J H; Gao, Yanfei; Liaw, Peter K; Zhang, Wei; He, Wei

    2015-10-01

    Despite the prevalent use of crystalline alloys in current vascular stent technology, new biomaterials are being actively sought after to improve stent performance. In this study, we demonstrated the potential of a Zr-Al-Fe-Cu bulk metallic glass (BMG) to serve as a candidate stent material. The mechanical properties of the Zr-based BMG, determined under both static and cyclic loadings, were characterized by high strength, which would allow for the design of thinner stent struts to improve stent biocompatibility. Finite element analysis further complemented the experimental results and revealed that a stent made of the Zr-based BMG was more compliant with the beats of a blood vessel, compared with medical 316L stainless steel. The Zr-based BMG was found to be corrosion resistant in a simulated body environment, owing to the presence of a highly stable ZrO2-rich surface passive film. Application-specific biocompatibility studies were conducted using human aortic endothelial cells and smooth muscle cells. The Zr-Al-Fe-Cu BMG was found to support stronger adhesion and faster coverage of endothelial cells and slower growth of smooth muscle cells than 316L stainless steel. These results suggest that the Zr-based BMG could promote re-endothelialization and potentially lower the risk of restenosis, which are critical to improve vascular stent implantation integration. In general, findings in this study raised the curtain for the potential application of BMGs as future candidates for stent applications. Vascular stents are medical devices typically used to restore the lumen of narrowed or clogged blood vessel. Despite the clinical success of metallic materials in stent-assisted angioplasty, post-surgery complications persist due to the mechanical failures, corrosion, and in-stent restenosis of current stents. To overcome these hurdles, strategies including new designs and surface functionalization have been exercised. In addition, the development of new materials with higher performance and biocompatibility can intrinsically reduce stent failure rates. The present study demonstrates the advantages of a novel material, named bulk metallic glass (BMG), over the benchmarked 316L stainless steel through experimental methods and computational simulations. It raises the curtain of new research endeavors on BMGs as competitive alternatives for stent applications. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Pupil Inquiry Behavior Analysis and Change Activity. Interim Project Report.

    ERIC Educational Resources Information Center

    Manion, Raymond C.

    This interim report discusses progress toward three major goals of the Pupil Inquiry Behavior Analysis and Change Activity: increased pupil inquiry, changed teacher behavior to facilitate pupil inquiry, and the development of a 32-week course of instruction to provide for these behavioral changes. Data currently available deals with the emotional…

  12. Analysis of trends and prospects regarding stents for human blood vessels.

    PubMed

    Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo

    2018-01-01

    The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used to supplement and complement the primary research. Interviews were conducted with physicians and surgeons from the key hospitals and senior sale/marketing managers from stent product suppliers in South Korea. The global stent market is estimated at US $ 7.98 billion in 2016 and is expected to grow at a Compound Annual Growth Rate (CAGR) of 3.8% over the next 5 years. As of 2016, the global market for vascular stents is estimated at $ 7.22 billion, with coronary artery stents accounting for 67.3% of the vascular stent market. Among the coronary artery stents, BRS is notably expected to grow at an annual average rate of 8.8% by 2020, but the global adoption rate of BRS remains low at present. In the Korean market, stents for blood vessels account for most of the market, and the market size of stents for blood vessels in Korea was estimated to be 145 billion won as of 2016. In comparison to the sales growth rate of other medical devices, the future stent technology market is judged to be higher in growth potential.

  13. Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation

    PubMed Central

    Lee, Tae Hoon; Jang, Bong Seok; Jung, Min Kyo; Pack, Chan Gi; Choi, Jun-Ho; Park, Do Hyun

    2016-01-01

    To reduce tissue or tumor ingrowth, covered self-expandable metal stents (SEMSs) have been developed. The effectiveness of covered SEMSs may be attenuated by sludge or stone formation or by stent clogging due to the formation of biofilm on the covering membrane. In this study, we tested the hypothesis that a silicone membrane containing silver particles (Ag-P) would prevent sludge and biofilm formation on the covered SEMS. In vitro, the Ag-P-integrated silicone polymer-covered membrane exhibited sustained antibacterial activity, and there was no definite release of silver ions from the Ag-P-integrated silicone polymer membrane at any time point. Using a porcine stent model, in vivo analysis demonstrated that the Ag-P-integrated silicone polymer-covered SEMS reduced the thickness of the biofilm and the quantity of sludge formed, compared with a conventional silicone-covered SEMS. In vivo, the release of silver ions from an Ag-P-integrated silicone polymer-covered SEMS was not detected in porcine serum. The Ag-P-integrated silicone polymer-covered SEMS also resulted in significantly less stent-related bile duct and subepithelium tissue inflammation than a conventional silicone polymer-covered SEMS. Therefore, the Ag-P-integrated silicone polymer-covered SEMS reduced sludge and biofilm formation and stent-induced pathological changes in tissue. This novel SEMS may prolong the stent patency in clinical application. PMID:27739486

  14. Complications and outcomes of JJ stenting of the ureter in urological practice: A single-centre experience☆

    PubMed Central

    Al-Marhoon, Mohammed S.; Shareef, Omar; Venkiteswaran, Krishna P.

    2012-01-01

    Objective To determine the factors affecting the development of complications and the outcomes of JJ stenting. Patients and methods The study included 220 patients (133 males and 87 females, mean age 39.5 years, SD 15.4) who had self-retaining JJ ureteric stents placed while in the authors’ institution. Univariate and multivariate analyses were used to identify the significant variables affecting the development of complications and outcome of stenting (condition ‘improved’ or ‘not improved’). Results Using a modified Clavien classification, there were grade I, II, IIIa, IIIb complications in 67 (30.4%), 39 (17.7%), two (0.9%) and 23 (10.5%) patients, respectively, and none of grades IVa, IVb and V. Loin pain (10.9%) and urinary tract infection (10.9%) were the most common complications, followed by dysuria (7.7%). There were significant complications requiring treatment in 29% of patients, and 71.4% of patients improved after stenting. On multivariate analysis the significant independent factor affecting the complication rate was the stent length (P = 0.016), and the significant independent factor affecting the ‘improved’ outcome was age (P = 0.014). Conclusion Longer stents are associated with increased complication rates, and the older the patient the more likely they are to have a poor outcome after stenting. Future prospective multicentre studies with more patients are needed to confirm the present conclusions. PMID:26558052

  15. Complications and outcomes of JJ stenting of the ureter in urological practice: A single-centre experience.

    PubMed

    Al-Marhoon, Mohammed S; Shareef, Omar; Venkiteswaran, Krishna P

    2012-12-01

    To determine the factors affecting the development of complications and the outcomes of JJ stenting. The study included 220 patients (133 males and 87 females, mean age 39.5 years, SD 15.4) who had self-retaining JJ ureteric stents placed while in the authors' institution. Univariate and multivariate analyses were used to identify the significant variables affecting the development of complications and outcome of stenting (condition 'improved' or 'not improved'). Using a modified Clavien classification, there were grade I, II, IIIa, IIIb complications in 67 (30.4%), 39 (17.7%), two (0.9%) and 23 (10.5%) patients, respectively, and none of grades IVa, IVb and V. Loin pain (10.9%) and urinary tract infection (10.9%) were the most common complications, followed by dysuria (7.7%). There were significant complications requiring treatment in 29% of patients, and 71.4% of patients improved after stenting. On multivariate analysis the significant independent factor affecting the complication rate was the stent length (P = 0.016), and the significant independent factor affecting the 'improved' outcome was age (P = 0.014). Longer stents are associated with increased complication rates, and the older the patient the more likely they are to have a poor outcome after stenting. Future prospective multicentre studies with more patients are needed to confirm the present conclusions.

  16. Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation.

    PubMed

    Lee, Tae Hoon; Jang, Bong Seok; Jung, Min Kyo; Pack, Chan Gi; Choi, Jun-Ho; Park, Do Hyun

    2016-10-14

    To reduce tissue or tumor ingrowth, covered self-expandable metal stents (SEMSs) have been developed. The effectiveness of covered SEMSs may be attenuated by sludge or stone formation or by stent clogging due to the formation of biofilm on the covering membrane. In this study, we tested the hypothesis that a silicone membrane containing silver particles (Ag-P) would prevent sludge and biofilm formation on the covered SEMS. In vitro, the Ag-P-integrated silicone polymer-covered membrane exhibited sustained antibacterial activity, and there was no definite release of silver ions from the Ag-P-integrated silicone polymer membrane at any time point. Using a porcine stent model, in vivo analysis demonstrated that the Ag-P-integrated silicone polymer-covered SEMS reduced the thickness of the biofilm and the quantity of sludge formed, compared with a conventional silicone-covered SEMS. In vivo, the release of silver ions from an Ag-P-integrated silicone polymer-covered SEMS was not detected in porcine serum. The Ag-P-integrated silicone polymer-covered SEMS also resulted in significantly less stent-related bile duct and subepithelium tissue inflammation than a conventional silicone polymer-covered SEMS. Therefore, the Ag-P-integrated silicone polymer-covered SEMS reduced sludge and biofilm formation and stent-induced pathological changes in tissue. This novel SEMS may prolong the stent patency in clinical application.

  17. Biofilm Quantification on Nasolacrimal Silastic Stents After Dacryocystorhinostomy.

    PubMed

    Murphy, Jae; Ali, Mohammed Javed; Psaltis, Alkis James

    2015-01-01

    Biofilms are now recognized as potential factors in the pathogenesis of chronic inflammatory and infective diseases. The aim of this study was to examine the presence of biofilms and quantify their biomass on silastic nasolacrimal duct stents inserted after dacryocystorhinostomy (DCR). A prospective study was performed on a series of patients undergoing DCR with O'Donoghue stent insertion. After removal, the stents were subjected to biofilm analysis using standard protocols of confocal laser scanning microscopy (CLSM) and scanning electron microscopy. These stents were compared against negative controls and positive in vitro ones established using Staphylococcus aureus strain ATCC 25923. Biofilm quantification was performed using the COMSTAT2 software and the total biofilm biomass was calculated. A total of nine consecutive patient samples were included in this prospective study. None of the patients had any evidence of postoperative infection. All the stents demonstrated evidence of biofilm formation using both imaging modalities. The presence of various different sized organisms within a common exopolysaccharide matrix on CLSM suggested the existence of polymicrobial communities. The mean biomass of patient samples was 0.9385 μm³/μm² (range: 0.3901-1.9511 μm³/μm²). This is the first study to report the quantification of biomass on lacrimal stents. The presence of biofilms on lacrimal stents after DCR is a common finding but this need not necessarily translate to postoperative clinical infection.

  18. Publishing interim results of randomised clinical trials in peer-reviewed journals.

    PubMed

    Counsell, Nicholas; Biri, Despina; Fraczek, Joanna; Hackshaw, Allan

    2017-02-01

    Interim analyses of randomised controlled trials are sometimes published before the final results are available. In several cases, the treatment effects were noticeably different after patient recruitment and follow-up completed. We therefore conducted a literature review of peer-reviewed journals to compare the reported treatment effects between interim and final publications and to examine the magnitude of the difference. We performed an electronic search of MEDLINE from 1990 to 2014 (keywords: 'clinical trial' OR 'clinical study' AND 'random*' AND 'interim' OR 'preliminary'), and we manually identified the corresponding final publication. Where the electronic search produced a final report in which the abstract cited interim results, we found the interim publication. We also manually searched every randomised controlled trial in eight journals, covering a range of impact factors and general medical and specialist publications (1996-2014). All paired articles were checked to ensure that the same comparison between interventions was available in both. In all, 63 studies are included in our review, and the same quantitative comparison was available in 58 of these. The final treatment effects were smaller than the interim ones in 39 (67%) trials and the same size or larger in 19 (33%). There was a marked reduction, defined as a ≥20% decrease in the size of the treatment effect from interim to final analysis, in 11 (19%) trials compared to a marked increase in 3 (5%), p = 0.057. The magnitude of percentage change was larger in trials where commercial support was reported, and increased as the proportion of final events at the interim report decreased in trials where commercial support was reported (interaction p = 0.023). There was no evidence of a difference between trials that stopped recruitment at the interim analysis where this was reported as being pre-specified versus those that were not pre-specified (interaction p = 0.87). Published interim trial results were more likely to be associated with larger treatment effects than those based on the final report. Publishing interim results should be discouraged, in order to have reliable estimates of treatment effects for clinical decision-making, regulatory authority reviews and health economic analyses. Our work should be expanded to include conference publications and manual searches of additional journal publications.

  19. Fully covered self-expanding metal stents for refractory anastomotic colorectal strictures.

    PubMed

    Caruso, Angelo; Conigliaro, Rita; Manta, Raffaele; Manno, Mauro; Bertani, Helga; Barbera, Carmelo; Mirante, Vincenzo Giorgio; Frazzoni, Marzio

    2015-05-01

    Some patients with benign colorectal obstruction do not respond to endoscopic balloon dilation. Fully covered self-expandable metal stents (FCSEMSs) have several potential advantages over non-covered stents, including a higher likelihood of retrieval owing to limited local tissue reaction. However, the efficacy and safety of FCSEMSs in benign colorectal strictures have not yet been established. Retrospective analysis of prospectively collected data concerning patients with post-surgical benign symptomatic anastomotic colorectal strictures, refractory to endoscopic dilation and in whom FCSEMSs had been placed at our center. Technical success was defined as successful stent placement and deployment at the stricture site. Early clinical success was defined as symptom relief persisting at least for 3 days. Follow-up was based on monthly clinical evaluation and quarterly endoscopic assessment. Endoscopic stent removal was planned on the basis of clinical or endoscopic assessment. Prolonged clinical success was defined as persistent symptom relief during follow-up. Technical and early clinical success were obtained in 16 of 16 (100%) patients. The median follow-up was 21 months. Prolonged clinical success was achieved in 9/16 (56%) cases. There was no major complication, including perforation and bleeding. Stent migration occurred in 3 (19%) cases, in two of them associated with clinical failure. The median stent diameter was significantly higher in patients with successful than in those with unsuccessful clinical outcome (26 vs. 20 mm, P = 0.006). The clinical success rate was 1/6 (17%) in patients who received a 20-22 mm stent and 8/10 (80%) in those who received a 24-26 mm stent, respectively (P = 0.035). FCSEMSs can represent effective and safe treatment for refractory anastomotic colorectal strictures. Large diameter stents are warranted for better results.

  20. The Use of Biodegradable Stents in Malignant Oesophageal Strictures for the Treatment of Dysphagia Before Neoadjuvant Treatment or Radical Radiotherapy: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Burke, Chris; Spiliopoulos, Stavros

    PurposeTo evaluate the clinical results of the use of biodegradable oesophageal stents in malignant strictures.MethodsEleven patients were included in this prospective analysis in which a woven polydioxanone biodegradable oesophageal stent was used. The inclusion criterion was that the patient underwent neoadjuvant treatment or radical radiotherapy after the stent insertion. Primary end points were dysphagia score at discharge, stent patency, and complication rate. Secondary end points were overall survival and surgical outcome of surgery.ResultsThere was a 100 % procedure technical success rate. Early complications occurred in three patients resulting in failure to restore oral nutrition. In the remaining eight patients, dysphagiamore » was significantly improved at discharge. Mean stent patency rate in this group was 71.5 days. Stent dysfunction occurred in five of eight patients (62.5 %); in two of five patients this was due to local inflammatory reaction, and in three of five patients it was due to tumour growth after a mean time of 97.8 days, and a new metallic stent was consequently placed in four of five patients. One patient was successfully treated with esophagectomy. At the end of follow-up (mean time 102.1 days), three of eight stents were patent. The overall patient survival rate was 81.8 %.ConclusionAlthough short-term dysphagia scores improved, biodegradable stents do not appear to offer a clear beneficial effect in most cases of malignant strictures, particularly due to a local inflammatory reaction that may be induced. Technical improvement of the device and delineation of the patient group that would benefit from its use is necessary if further studies are to be conducted in the future.« less

  1. Outcome of self-expandable metallic stent deployment in patients with malignant gastroduodenal outlet obstruction and Niti-S and WallFlex comparison: a multicenter retrospective clinical study.

    PubMed

    Kato, Hironari; Kawamoto, Hirofumi; Matsumoto, Kazuya; Moriyama, Ichiro; Kamada, Hideki; Tsutsumi, Koichiro; Goto, Daisuke; Fukuba, Nobuhiko; Kato, Kiyohito; Sonoyama, Hiroki; Isomoto, Hajime; Okada, Hiroyuki

    2016-08-01

    Several studies report on the outcomes of self-expandable metallic stents (SEMSs) deployment for malignant gastric outlet obstruction (GOO). However, data was mostly based on the analysis of single-center studies including only a small number of patients. This study aimed to evaluate clinical outcomes after the deployment of SEMS in patients with malignant GOO and to compare the clinical outcomes of two metallic stents with different designs. Altogether 125 consecutive patients from five institutions were included. Clinical outcomes were evaluated according to technical success, clinical success, stent patency period, survival period and complications. A comparison of clinical outcomes between Niti-S pyloric/duodenal and WallFlex duodenal stents was also undertaken. Rates for clinical and technical success were 100% and 92.0%, respectively. The median stent patency and survival periods were 72.0 days (range 3-775 days) and 75.0 days (range 3-775 days), respectively. The rate of overall adverse events was 28.8%. The rate of stent dysfunction was 16.8%, and that of adverse events, except stent dysfunction was 12.0%. Massive bleeding occurred in two patients as a late complication. The clinical success rate for Niti-S stent was significantly higher than that for WallFlex stent (96.2% vs 84.8%, P = 0.023). We successfully deployed a SEMS in malignant GOO. The selection of a SEMS with a lower axial force may be important for patients to resume the oral food intake. Additionally, consideration must be given to the appropriate management of fatal bleeding as a late complication. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  2. Long-term (>3 Years) outcome and predictors of clinical events after insertion of sirolimus-eluting stent in one or more native coronary arteries (from the Israeli arm of the e-Cypher registry).

    PubMed

    Planer, David; Beyar, Rafael; Almagor, Yaron; Banai, Shmuel; Guetta, Victor; Miller, Hilton; Kornowski, Ran; Brandes, Simcha; Krakover, Ricardo; Solomon, Mivi; Lotan, Chaim

    2008-04-01

    The aim of this study was to evaluate long-term (3.4 years) outcomes and predictors of clinical events in patients treated with sirolimus-eluting stents in the Israeli arm of the e-Cypher registry. From July 2002 to October 2003, 488 patients from 8 medical centers in Israel were enrolled in the e-Cypher registry. Nineteen patients with interventions in venous grafts were excluded from the final analysis. Long-term follow-up was completed for 98% of the remaining patients. There were 29 cases (6.3%) of death (3.9% cardiac and 2.4% noncardiac deaths). According to the broad academic research consortium definition of stent thrombosis, there were 19 cases (4%) of stent thrombosis (incidence density 0.9 cases/100 patient-years). There were 46 cases (9.9%) of target lesion revascularization and 76 cases (16.3%) of major adverse cardiac events (combination of death, myocardial infarction, and target lesion revascularization). Independent predictors of stent thrombosis were renal failure (hazard ratio 9.6, 95% confidence interval 1.9 to 47), stent length (hazard ratio 1.1, 95% confidence interval 1 to 1.2), and the off-label use of sirolimus-eluting stents (hazard ratio 5.3, 95% confidence interval 1.2 to 24). In conclusion, during >3 years of follow-up, stent thrombosis, major adverse cardiac events, and target lesion revascularization continued at constant rates over time. Clinical parameters such as renal failure and procedural parameters such as off-label use and stent length were independent predictors of stent thrombosis.

  3. Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study.

    PubMed

    Berg, Philipp; Iosif, Christina; Ponsonnard, Sebastien; Yardin, Catherine; Janiga, Gábor; Mounayer, Charbel

    2016-01-04

    Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of different treatment scenarios, over- and undersized stent deployments were realized experimentally and computationally. Two Pipeline Embolization Devices were placed in the right common carotid artery of large white swine, crossing the right ascending pharyngeal artery. DSA and PC-MRI measurements were acquired pre- and post-stenting and after three months. To evaluate the stent strut endothelialization and the corresponding ostium patency, the swine were sacrificed and scanning electron microscopy measurements were carried out. A more detailed analysis of the near-stent hemodynamics was enabled by a realistic virtual stenting in combination with highly resolved Computational Fluid Dynamics simulations using case-specific boundary conditions. The oversizing resulted in an elongated stent deployment with more open stent pores, while for the undersized case a shorter deployment with more condensed pores was present. In consequence, the side branch of the first case remained patent after three months and the latter almost fully occluded. The virtual investigation confirmed the experimental findings by identifying differences between the individual velocities as well as stent shear stresses at the distal part of the ostia. The choice of flow-diverting device and the subsequent deployment strategy strongly influences the patency of jailed side branches. Therefore, careful treatment planning is required, to guarantee sufficient blood supply in the brain territories supplied those branches. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Sirolimus-eluting Biodegradable Poly-l-Lactic Acid Stent to Suppress Granulation Tissue Formation in the Rat Urethra.

    PubMed

    Kim, Kun Yung; Park, Jung-Hoon; Kim, Do Hoon; Tsauo, Jiaywei; Kim, Min Tae; Son, Woo-Chan; Kang, Sung-Gwon; Kim, Dong-Hyun; Song, Ho-Young

    2018-01-01

    Purpose To investigate the use of sirolimus-eluting biodegradable stents (SEBSs) to suppress granulation tissue formation after stent placement in a rat urethral model. Materials and Methods All experiments were approved by the animal research committee. A total of 36 male Sprague-Dawley rats were randomized into three equal groups after biodegradable stent placement. Group A received control biodegradable stents. Groups B and C received stents coated with 90 µg/cm 2 and 450 µg/cm 2 sirolimus, respectively. Six rats in each group were sacrificed after 4 weeks; the remaining rats were sacrificed after 12 weeks. The therapeutic effectiveness of SEBSs was assessed by comparing the results of retrograde urethrography and histologic examination. Analysis of variance with post hoc comparisons was used to evaluate statistical differences. Results SEBS placement was technically successful in all rats. Urethrographic and histologic examinations revealed significantly less granulation tissue formation at both time points in the rats receiving SEBSs (groups B and C) compared with those that received control stents (group A) (P < .05 for all). There were no significant differences in urethrographic and histologic findings between groups B and C (P > .05 for all). However, the mean number of epithelial layers in group B was higher than that in group C at 4 weeks after stent placement (P < .001). Apoptosis increased in group C compared with groups A and B (P < .05 for all). Conclusion The use of SEBSs suppressed granulation tissue formation secondary to stent placement in a rat urethral model; local therapy with SEBSs may be used to decrease stent-related granulation tissue formation. © RSNA, 2017.

  5. Clinical outcome after intrahepatic venous stent placement for malignant inferior vena cava syndrome.

    PubMed

    Brountzos, Elias N; Binkert, Christoph A; Panagiotou, Irene E; Petersen, Bryan D; Timmermans, Hans; Lakin, Paul C

    2004-01-01

    We evaluated the clinical outcome of malignant inferior vena cava (IVC) syndrome after intrahepatic IVC stent placement by retrospective analysis of 50 consecutive patients (25 men, 25 women, age 32-83 years) with malignant IVC syndrome who were treated with intrahepatic stent placement. Gianturco-Rosch-Z (GRZ) stents (n = 45), and Wallstents (n = 5) were inserted. Clinical outcome was assessed from patients' records using a score based on leg swelling, scrotal/vulvar edema, ascites and anasarca before and after stent placement, as well as at last follow-up visit before death. Clinical follow-up was supplemented by duplex sonography in 36 patients. Inferior venocavography was performed in 5 patients prior to re- intervention. Follow-up time ranged from 1 to 932 days (mean 62 days). Mean pressure gradient in the IVC was reduced from 14 +/- 4.1 mmHg before to 2.9 +/- 3.2 mmHg after stent placement (p < 0.001). Four patients had stent occlusion, 2 of whom were successfully re-stented. Primary and secondary patency was 59% and 100%, respectively at 540 days. Immediate clinical data were available in 44 patients: 38 improved; 6 did not respond. Last follow-up visit data were available in 36 patients: 24 showed persistent symptom relief till death. All symptom scores were significantly improved after stent placement (p < 0.001) and with the exception of ascites, remained significantly improved (p < 0.05) until the last follow-up. Increased serum bilirubin was a common characteristic of clinical failures and recurrences. Intrahepatic IVC stent placement resulted in significant symptomatic relief in patients with malignant IVC syndrome. Palliation was effective even in patients with a very short life expectancy.

  6. Epidemiology and Resistance Patterns of Bacterial and Fungal Colonization of Biliary Plastic Stents: A Prospective Cohort Study

    PubMed Central

    Lübbert, Christoph; Wendt, Karolin; Feisthammel, Jürgen; Moter, Annette; Lippmann, Norman; Busch, Thilo; Mössner, Joachim; Hoffmeister, Albrecht; Rodloff, Arne C.

    2016-01-01

    Background Plastic stents used for the treatment of biliary obstruction will become occluded over time due to microbial colonization and formation of biofilms. Treatment of stent-associated cholangitis is often not effective because of inappropriate use of antimicrobial agents or antimicrobial resistance. We aimed to assess the current bacterial and fungal etiology of stent-associated biofilms, with particular emphasis on antimicrobial resistance. Methods Patients with biliary strictures requiring endoscopic stent placement were prospectively enrolled. After the retrieval of stents, biofilms were disrupted by sonication, microorganisms were cultured, and isolates were identified by matrix-associated laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and/or biochemical typing. Finally, minimum inhibitory concentrations (MICs) were determined for various antimicrobial agents. Selected stents were further analyzed by fluorescence in situ hybridization (FISH). Results Among 120 patients (62.5% males, median age 64 years) with biliary strictures (35% malignant, 65% benign), 113 double pigtail polyurethane and 100 straight polyethylene stents were analyzed after a median indwelling time of 63 days (range, 1–1274 days). The stent occlusion rate was 11.5% and 13%, respectively, being associated with a significantly increased risk of cholangitis (38.5% vs. 9.1%, P<0.001). Ninety-five different bacterial and 13 fungal species were detected; polymicrobial colonization predominated (95.8% vs. 4.2%, P<0.001). Enterococci (79.3%), Enterobacteriaceae (73.7%), and Candida spp. (55.9%) were the leading pathogens. Candida species were more frequent in patients previously receiving prolonged antibiotic therapy (63% vs. 46.7%, P = 0.023). Vancomycin-resistant enterococci accounted for 13.7%, extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae with co-resistance to ciprofloxacin accounted for 13.9%, and azole-resistant Candida spp. accounted for 32.9% of the respective isolates. Conclusions Enterococci and Candida species play an important role in the microbial colonization of biliary stents. Therefore, empirical antimicrobial treatment of stent-associated cholangitis should be guided toward enterococci, Enterobacteriaceae, streptococci, anaerobes, and Candida. To determine causative pathogens, an accurate microbiological analysis of the extracted stent(s) may be helpful. PMID:27171497

  7. Epidemiology and Resistance Patterns of Bacterial and Fungal Colonization of Biliary Plastic Stents: A Prospective Cohort Study.

    PubMed

    Lübbert, Christoph; Wendt, Karolin; Feisthammel, Jürgen; Moter, Annette; Lippmann, Norman; Busch, Thilo; Mössner, Joachim; Hoffmeister, Albrecht; Rodloff, Arne C

    2016-01-01

    Plastic stents used for the treatment of biliary obstruction will become occluded over time due to microbial colonization and formation of biofilms. Treatment of stent-associated cholangitis is often not effective because of inappropriate use of antimicrobial agents or antimicrobial resistance. We aimed to assess the current bacterial and fungal etiology of stent-associated biofilms, with particular emphasis on antimicrobial resistance. Patients with biliary strictures requiring endoscopic stent placement were prospectively enrolled. After the retrieval of stents, biofilms were disrupted by sonication, microorganisms were cultured, and isolates were identified by matrix-associated laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and/or biochemical typing. Finally, minimum inhibitory concentrations (MICs) were determined for various antimicrobial agents. Selected stents were further analyzed by fluorescence in situ hybridization (FISH). Among 120 patients (62.5% males, median age 64 years) with biliary strictures (35% malignant, 65% benign), 113 double pigtail polyurethane and 100 straight polyethylene stents were analyzed after a median indwelling time of 63 days (range, 1-1274 days). The stent occlusion rate was 11.5% and 13%, respectively, being associated with a significantly increased risk of cholangitis (38.5% vs. 9.1%, P<0.001). Ninety-five different bacterial and 13 fungal species were detected; polymicrobial colonization predominated (95.8% vs. 4.2%, P<0.001). Enterococci (79.3%), Enterobacteriaceae (73.7%), and Candida spp. (55.9%) were the leading pathogens. Candida species were more frequent in patients previously receiving prolonged antibiotic therapy (63% vs. 46.7%, P = 0.023). Vancomycin-resistant enterococci accounted for 13.7%, extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae with co-resistance to ciprofloxacin accounted for 13.9%, and azole-resistant Candida spp. accounted for 32.9% of the respective isolates. Enterococci and Candida species play an important role in the microbial colonization of biliary stents. Therefore, empirical antimicrobial treatment of stent-associated cholangitis should be guided toward enterococci, Enterobacteriaceae, streptococci, anaerobes, and Candida. To determine causative pathogens, an accurate microbiological analysis of the extracted stent(s) may be helpful.

  8. Subintimal Recanalization of Occluded Stents: The Substent Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diamantopoulos, Athanasios, E-mail: adiamant@upatras.gr; Katsanos, Konstantinos; Spiliopoulos, Stavros

    2013-08-01

    PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end pointsmore » included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan-Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 {+-} 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 {+-} 90.78 mm. The mean occluded stented segment length was 90.21 {+-} 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year's follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few alternatives.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVRmore » > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.« less

  10. Randomised comparison of drug-eluting versus bare-metal stenting in patients with non-ST elevation myocardial infarction.

    PubMed

    Remkes, Wouter S; Badings, Erik A; Hermanides, Renicus S; Rasoul, Saman; Dambrink, Jan-Henk E; Koopmans, Petra C; The, Salem Hk; Ottervanger, Jan Paul; Gosselink, A T Marcel; Hoorntje, Jan Ca; Suryapranata, Harry; van 't Hof, Arnoud Wj

    2016-01-01

    The superiority of drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ST elevation myocardial infarction (STEMI) is well studied; however, randomised data in patients with non-ST elevation myocardial infarction (NSTEMI) are lacking. The objective of this study was to investigate whether stenting with everolimus-eluting stents (EES) safely reduces restenosis in patients with NSTEMI as compared to BMS. ELISA-3 patients were asked to participate in the angiographic substudy and were randomised to DE (Xience V) or BM (Vision) stenting (ELISA-3 group). The primary end point was minimal luminal diameter (MLD) at 9-month follow-up angiography. In addition, 296 patients with NSTEMI who were excluded or did not want to participate in the ELISA-3 trial (RELI group) were randomised to DE or BM stenting and underwent clinical follow-up only (major adverse cardiac events (MACE), stent thrombosis (ST)). A pooled analysis was performed to assess an effect on clinical outcome. 178 of 540 ELISA-3 patients participated in the angiographic substudy. MLD at 9 months angiography was 2.37±0.63 mm (DES) versus 1.84±0.62 mm (BMS), p<0.001. Binary restenosis occurred in 1.9% in the DES group versus 16.7% in the BMS group (RR 0.11, 95% CI 0.02 to 0.84, p=0.007). In the pooled analysis, the incidence of MACE, target vessel revascularisation and ST at 2 years follow-up in the DES versus BMS group was 12.5% versus 16.0% (p=0.28), 4.0% versus 10.4% (p=0.009) and 1.3% versus 3.0% (p=0.34), respectively. In patients with NSTEMI, use of EES is safe and decreases both angiographic and clinical restenosis as compared to BMS http://www.isrctn.com/search?q=39230163. 39230163; Post-results.

  11. Randomised comparison of drug-eluting versus bare-metal stenting in patients with non-ST elevation myocardial infarction

    PubMed Central

    Remkes, Wouter S; Badings, Erik A; Hermanides, Renicus S; Rasoul, Saman; Dambrink, Jan-Henk E; Koopmans, Petra C; The, Salem HK; Ottervanger, Jan Paul; Gosselink, A T Marcel; Hoorntje, Jan CA; Suryapranata, Harry; van 't Hof, Arnoud WJ

    2016-01-01

    Objective The superiority of drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ST elevation myocardial infarction (STEMI) is well studied; however, randomised data in patients with non-ST elevation myocardial infarction (NSTEMI) are lacking. The objective of this study was to investigate whether stenting with everolimus-eluting stents (EES) safely reduces restenosis in patients with NSTEMI as compared to BMS. Methods ELISA-3 patients were asked to participate in the angiographic substudy and were randomised to DE (Xience V) or BM (Vision) stenting (ELISA-3 group). The primary end point was minimal luminal diameter (MLD) at 9-month follow-up angiography. In addition, 296 patients with NSTEMI who were excluded or did not want to participate in the ELISA-3 trial (RELI group) were randomised to DE or BM stenting and underwent clinical follow-up only (major adverse cardiac events (MACE), stent thrombosis (ST)). A pooled analysis was performed to assess an effect on clinical outcome. Results 178 of 540 ELISA-3 patients participated in the angiographic substudy. MLD at 9 months angiography was 2.37±0.63 mm (DES) versus 1.84±0.62 mm (BMS), p<0.001. Binary restenosis occurred in 1.9% in the DES group versus 16.7% in the BMS group (RR 0.11, 95% CI 0.02 to 0.84, p=0.007). In the pooled analysis, the incidence of MACE, target vessel revascularisation and ST at 2 years follow-up in the DES versus BMS group was 12.5% versus 16.0% (p=0.28), 4.0% versus 10.4% (p=0.009) and 1.3% versus 3.0% (p=0.34), respectively. Conclusions In patients with NSTEMI, use of EES is safe and decreases both angiographic and clinical restenosis as compared to BMS http://www.isrctn.com/search?q=39230163. Trial registration number 39230163; Post-results. PMID:27933192

  12. Cost-Effectiveness Analysis of Infrapopliteal Drug-Eluting Stents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Karnabatidis, Dimitris; Diamantopoulos, Athanasios

    2013-02-15

    IntroductionThere are no cost-utility data about below-the-knee placement of drug-eluting stents. The authors determined the cost-effectiveness of infrapopliteal drug-eluting stents for critical limb ischemia (CLI) treatment. The event-free individual survival outcomes defined by the absence of any major events, including death, major amputation, and target limb repeat procedures, were reconstructed on the basis of two published infrapopliteal series. The first included spot Bail-out use of Sirolimus-eluting stents versus bare metal stents after suboptimal balloon angioplasty (Bail-out SES).The second was full-lesion Primary Everolimus-eluting stenting versus plain balloon angioplasty and bail-out bare metal stenting as necessary (primary EES). The number-needed-to-treat (NNT) tomore » avoid one major event and incremental cost-effectiveness ratios (ICERs) were calculated for a 3-year postprocedural period for both strategies. Overall event-free survival was significantly improved in both strategies (hazard ratio (HR) [confidence interval (CI)]: 0.68 [0.41-1.12] in Bail-out SES and HR [CI]: 0.53 [0.29-0.99] in Primary EES). Event-free survival gain per patient was 0.89 (range, 0.11-3.0) years in Bail-out SES with an NNT of 4.6 (CI: 2.5-25.6) and a corresponding ICER of 6,518 Euro-Sign (range 1,685-10,112 Euro-Sign ). Survival gain was 0.91 (range 0.25-3.0) years in Primary EES with an NNT of 2.7 (CI: 1.7-5.8) and an ICER of 11,581 Euro-Sign (range, 4,945-21,428 Euro-Sign ) per event-free life-year gained. Two-way sensitivity analysis showed that stented lesion length >10 cm and/or DES list price >1000 Euro-Sign were associated with the least economically favorable scenario in both strategies. Both strategies of bail-out SES and primary EES placement in the infrapopliteal arteries for CLI treatment exhibit single-digit NNT and relatively low corresponding ICERs.« less

  13. Design considerations and quantitative assessment for the development of percutaneous mitral valve stent.

    PubMed

    Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt

    2014-07-01

    Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral regurgitation, by virtue of their key features as well as effective crimping. These models will be fabricated and put to all the aforementioned tests before being taken for animal trials. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. In-stent stenosis after stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases.

    PubMed

    Chalouhi, Nohra; Drueding, Ross; Starke, Robert M; Jabbour, Pascal; Dumont, Aaron S; Gonzalez, L Fernando; Rosenwasser, Robert; Tjoumakaris, Stavropoula

    2013-03-01

    Neuroform and Enterprise are widely used self-expanding stents designed to treat wide-necked intracranial aneurysms. To assess the incidence, clinical significance, predictors, and outcomes of in-stent stenosis (ISS). Angiographic studies and hospital records were retrospectively reviewed for 435 patients treated between 2005 and 2011 in our institution. A multivariable regression analysis was conducted to determine the predictors of ISS. The Neuroform stent was used in 264 patients (60.7%) and the Enterprise in 171 patients (39.3%). A total of 11 patients (2.5%) demonstrated some degree of ISS during the follow-up period at a mean time point of 4.2 months (range, 2-12 months). The stenosis was mild (< 50%) in 8 patients (1.8%), moderate (50-75%) in 2 patients (0.5%), and severe (> 75%) in 1 patient (0.2%). No patients were symptomatic or required further intervention. There was complete ISS resolution in 2 patients, partial resolution in 2 patients, and no change in 5 patients on follow-up angiography. Patients developing ISS were significantly younger than those without ISS (40.3 vs. 54.9 years; P < .001). ISS rates were 2.7% with the Neuroform and 2.3% with the Enterprise stent (P = .6). In multivariable analysis, younger patient age (odds ratio = 0.92; P = .008), carotid ophthalmic aneurysm location (odds ratio = 7.7; P =0.01), and carotid terminus aneurysm location (odds ratio = 8.1; P = .009) were strong independent predictors of ISS. The type of stent was not a predictive factor. Neuroform and Enterprise ISS is an uncommon, often transient, and clinically benign complication. Younger patients and those harboring anterior circulation aneurysms located at ophthalmic and carotid terminus locations are more likely to develop ISS.

  15. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials.

    PubMed

    Kheiri, Babikir; Osman, Mohammed; Abdalla, Ahmed; Ahmed, Sahar; Bachuwa, Ghassan; Hassan, Mustafa

    2018-05-11

    The use of drug-eluting stents (DES) vs bare-metal stents (BMS) in saphenous vein graft (SVG) lesions remains controversial. We conducted a meta-analysis of all randomized clinical trials comparing the outcomes of DES with BMS in SVG percutaneous coronary interventions. A search of PubMed, Embase, the Cochrane Register of Controlled Trials, and Clinicaltrials.gov was performed for all randomized clinical trials. We evaluated the short- and long-term clinical outcomes of the following: all-cause mortality, major adverse cardiovascular events (MACE), definite/probable stent thrombosis, target lesion revascularization (TLR), and target-vessel revascularization (TVR). From a total of 1582 patients in 6 randomized clinical trials, 797 had DES and 785 had BMS. Patients with DES had lower short-term MACE, TLR, and TVR in comparison with BMS (odds ratio [OR]: 0.56, 95% confidence interval [CI]: 0.35-0.91, P = 0.02; OR: 0.43, 95% CI: 0.19-0.99, P = 0.05; and OR: 0.45, 95% CI: 0.22-0.95, P = 0.04, respectively). However, there were no different outcomes for all-cause mortality (P = 0.63) or stent thrombosis (P = 0.21). With long-term follow-up, there were no significant reductions of MACE (P = 0.20), TLR (P = 0.57), TVR (P = 0.07), all-cause mortality (P = 0.29), and stent thrombosis (P = 0.76). The use of DES in SVG lesions was associated with lower short-term MACE, TLR, and TVR in comparison with BMS. However, there were no significant differences with long-term follow-up. © 2018 Wiley Periodicals, Inc.

  16. Endoscopic biliary stenting in irretrievable common bile duct stones: stent exchange or expectant management-tertiary-centre experience and systematic review.

    PubMed

    Mohammed, Noor; Pinder, Matthew; Harris, Keith; Everett, Simon M

    2016-07-01

    Conventional endoscopic duct clearance may not be possible in up to 10%-15% of common bile duct stones (CBDS). Sphincterotomy and biliary drainage by endoprosthesis have for many years been the mainstay of management in irretrievable stones. Recent years have seen the advent of sphincteroplasty or cholangioscopically-guided electrohydraulic lithotripsy (EHL) permitting duct clearance in majority of cases. However, when bile duct clearance is not possible, options include long-term stenting followed by elective stent exchange (ESE) 6-12 monthly or permanent stent insertion (PSI) in selected cases, but it is not clear which management strategy among ESE and PSI is preferable. A retrospective review of all patients in Leeds Teaching Hospitals NHS Trust who underwent plastic stent insertion for biliary access for difficult CBDS from January 2006 to December 2011 was undertaken. Adult patients with irretrievable CBDS who had plastic stent insertions throughout the follow-up period were included. Patients who underwent PSI and ESE annually were retrospectively reviewed to determine the long-term outcomes. A detailed systematic review was also performed, examining the outcomes of CBDS managed with stents. During the study period, 674 patients underwent 1769 biliary-stent-related procedures; of which, 246 patients met our inclusion criteria. 201 patients had subsequent duct clearance. 45 patients were, therefore, included in the final analysis, 28 of whom underwent annual ESEs and 17 PSIs. Patients in the PSI group had higher American Society of Anesthesiologists (ASA) scores compared with the ESE group. In the PSI group, 9/17 patients presented acutely with blocked stents, 5 of whom presented within 12 months. 2/9 patients were severely ill and died within a fortnight following the repeat endoscopic retrograde cholangiopancreatography (ERCP). In the ESE group, 4/28 patients had duct clearance in subsequent ERCPs, 1/28 patient presented with a blocked stent, and no biliary-related deaths were observed. The mean numbers of ERCPs performed were 0.52 and 1.95 in the PSI and ESE groups, respectively. Over 50% of patients treated with long-term stenting re-presented acutely with stent blockage, though many of these were before 12 months, meaning planned stent exchange would not have affected the outcome. Duct clearance using all possible modalities is the preferred option, but where not possible, management with biliary stenting either with elective exchange or permanent stenting remains a possibility for carefully selected patients, though maybe best suited to those with limited life expectancy.

  17. Predictors for adverse outcome after iliac angioplasty and stenting for limb-threatening ischemia.

    PubMed

    Timaran, Carlos H; Stevens, Scott L; Freeman, Michael B; Goldman, Mitchell H

    2002-09-01

    The role of iliac artery angioplasty and stenting (IAS) for the treatment of limb-threatening ischemia is not defined. IAS has been used primarily for patients with disabling claudication. Because poorer results have been shown in patients with critical ischemia after iliac artery angioplasty, the purpose of this study was to estimate the influence of risk factors on the outcome of iliac angioplasty and stent placement in patients with limb-threatening ischemia. During a 5-year period (from 1996 to 2001), 85 iliac angioplasty and stent placement procedures (107 stents) were performed in 31 women and 43 men with limb-threatening ischemia. Patients with claudication were specifically excluded. The criteria prepared by the Ad Hoc Committee on Reporting Standards (Society for Vascular Surgery/International Society for Cardiovascular Surgery) were followed to define the variables. The TransAtlantic InterSociety Consensus classification was used to characterize the type of iliac lesions. Both univariate (Kaplan-Meier [KM]) and multivariate analyses (Cox proportional hazards model) were used to determine the association between variables, cumulative patency, limb salvage, and survival. Indications for iliac angioplasty with stenting were ischemic rest pain (56%) and tissue loss (44%). Primary stenting was performed in 36 patients (42%). Stents were placed selectively after iliac angioplasty mainly for residual stenosis or pressure gradient (43%). Overall, primary stent patency rate was 90% at 1 year, 74% at 3 years, and 69% at 5 years. Primary stent patency rate was significantly reduced in women compared with men (KM, log-rank test, P <.001). Primary patency rates at 1, 3, and 5 years were 79%, 57%, and 38% for women and 92%, 88%, and 88% for men. Primary stent patency rate also was significantly reduced in patients with renal insufficiency (creatinine level, >1.6 mg/dL; KM, log-rank test, P <.001). Cox regression analysis identified female gender (relative risk, 5.1; 95% CI, 1.8 to 7.9; P =.002) and renal insufficiency (relative risk, 6.6; 95% CI, 1.6 to 14.2; P =.01) as independent predictors of decreased primary stent patency. No independent predictors for limb salvage and survival were identified. Women undergoing iliac angioplasty and stenting for limb-threatening ischemia have significantly reduced primary stent patency rates and may need additional procedures to obtain satisfactory clinical improvement and limb salvage. Patients with renal insufficiency and critical ischemia also have reduced primary stent patency rates after IAS. Limb salvage, as shown in this study, is not affected by previous iliac stent failure.

  18. A systematic review and meta-analysis of randomized trials and prospective studies comparing covered and bare self-expandable metal stents for the treatment of malignant obstruction in the digestive tract.

    PubMed

    Yang, Zhiping; Wu, Qiong; Wang, Fang; Ye, Xiaofei; Qi, Xingshun; Fan, Daiming

    2013-01-01

    Self-expandable metal stents (SEMS) are widely used for the palliative treatment of malignant gastrointestinal obstruction. Our aim was to evaluate the evidence comparing covered and bare SEMS in the digestive tract using meta-analytical techniques. A literature search was performed using PubMed, Cochrane Library, and Embase databases for comparative studies assessing the two types of stents. The primary outcomes of interest were stent patency and patient survival; second outcomes included technical success, clinical success, tumor ingrowth, tumor overgrowth, and stent migration. A random-effects model was conducted. Pooled analysis was done separately based on the different segments of the digestive tract. Eleven studies (8 randomized controlled trials and 3 prospective cohort studies) including a total of 1376 patients were identified. Covered SEMS were equivalent to bare SEMS in terms of technical success, clinical success, stent patency (gastroduodenal obstruction: HR =0.87, 95% CI 0.53-1.42; colorectal obstruction: HR =0.89, 95% CI 0.18-4.45; biliary obstruction: HR =0.73, 95% CI 0.41-1.32) and survival rates (esophageal obstruction: HR =1.80, 95% CI 0.73-4.44; gastroduodenal obstruction: HR =0.83, 95% CI 0.55-1.26; biliary obstruction: HR =0.99, 95% CI 0.77-1.28), although bare stents were more prone to tumor ingrowth (esophageal obstruction: RR =0.10, 95% CI 0.01-0.77; gastroduodenal obstruction: RR =0.12, 95% CI 0.03-0.55; colorectal obstruction: RR =0.21, 95% CI 0.06-0.70; biliary obstruction: RR =0.21, 95% CI 0.06-0.69), whereas covered stents had the higher risk of stent migration (gastroduodenal obstruction: RR =5.01, 95% CI 1.53-16.43; colorectal obstruction: RR =11.70, 95% CI 2.84-48.27; biliary obstruction: RR =8.11, 95% CI 1.47-44.76) and tumor overgrowth (biliary obstruction: RR =2.03, 95% CI 1.08-3.78). Both covered and bare SEMS are comparable in efficacy for the palliative treatment of malignant obstruction in the digestive tract. Each type of the stents has its own merit and demerit relatively.

  19. Prognostic value of interim FDG-PET in R-CHOP-treated diffuse large B-cell lymphoma: Systematic review and meta-analysis.

    PubMed

    Adams, Hugo J A; Kwee, Thomas C

    2016-10-01

    This study aimed to systematically review and meta-analyze the prognostic value of interim (18)F-fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET) in diffuse large B-cell lymphoma (DLBCL) patients treated with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisolone (R-CHOP). MEDLINE and EMBASE were systematically searched for suitable studies. Included studies were methodologically appraised, and results were summarized both descriptively and meta-analytically. Nine studies, comprising a total of 996 R-CHOP-treated DLBCL patients, were included. Overall, studies were of moderate methodological quality. The area under the summary receiver operating curve (AUC) of interim FDG-PET in predicting treatment failure and death were 0.651 and 0.817, respectively. There was no heterogeneity in diagnostic odds ratios across available studies (I(2)=0.0%). At multivariable analysis, 2 studies reported interim FDG-PET to have independent prognostic value in addition to the International Prognostic Index (IPI) in predicting treatment failure, whereas 3 studies reported that this was not the case. One study reported interim FDG-PET to have independent prognostic value in addition to the IPI in predicting death, whereas 2 studies reported that this was not the case. In conclusion, interim FDG-PET in R-CHOP-treated DLBCL has some correlation with outcome, but its prognostic value is homogeneously suboptimal across studies and it has not consistently proven to surpass the prognostic potential of the IPI. Moreover, there is a lack of studies that compared interim FDG-PET to the recently developed and superior National Comprehensive Cancer Network-IPI. Therefore, at present there is no scientific base to support the clinical use of interim FDG-PET in R-CHOP-treated DLBCL. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Meta-analysis of long-term clinical outcomes of everolimus-eluting stents.

    PubMed

    Toyota, Toshiaki; Shiomi, Hiroki; Morimoto, Takeshi; Kimura, Takeshi

    2015-07-15

    The superiority of everolimus-eluting stents (EES) over sirolimus-eluting stents (SES) for long-term clinical outcomes has not been yet firmly established. We conducted a systematic review and a meta-analysis of randomized controlled trials (RCTs) comparing EES directly with SES using the longest available follow-up data. We searched PubMed, the Cochrane database, and ClinicalTrials.gov for RCTs comparing outcomes between EES and SES and identified 13,434 randomly assigned patients from 14 RCTs. EES was associated with significantly lower risks than SES for definite stent thrombosis (ST), definite/probable ST, target-lesion revascularization (TLR), and major adverse cardiac events (MACE). The risks for all-cause death and myocardial infarction were similar between EES and SES. By the stratified analysis according to the timing after stent implantation, the favorable trend of EES relative to SES for ST, TLR, and MACE was consistently observed both within and beyond 1 year. The lower risk of EES relative to SES for MACE beyond 1 year was statistically significant (pooled odds ratio 0.77, 95% confidence interval 0.61 to 0.96, p = 0.02). In conclusion, the current meta-analysis of 14 RCTs directly comparing EES with SES suggested that EES provided improvement in both safety and efficacy; EES compared with SES was associated with significantly lower risk for definite ST, definite/probable ST, TLR, and MACE. The direction and magnitude of the effect beyond 1 year were comparable with those observed within 1 year. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    PubMed

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses

    NASA Astrophysics Data System (ADS)

    Hoi, Yiemeng; Ionita, Ciprian N.; Tranquebar, Rekha V.; Hoffmann, Kenneth R.; Woodward, Scott H.; Taulbee, Dale B.; Meng, Hui; Rudin, Stephen

    2006-03-01

    An asymmetric stent with low porosity patch across the intracranial aneurysm neck and high porosity elsewhere is designed to modify the flow to result in thrombogenesis and occlusion of the aneurysm and yet to reduce the possibility of also occluding adjacent perforator vessels. The purposes of this study are to evaluate the flow field induced by an asymmetric stent using both numerical and digital subtraction angiography (DSA) methods and to quantify the flow dynamics of an asymmetric stent in an in vivo aneurysm model. We created a vein-pouch aneurysm model on the canine carotid artery. An asymmetric stent was implanted at the aneurysm, with 25% porosity across the aneurysm neck and 80% porosity elsewhere. The aneurysm geometry, before and after stent implantation, was acquired using cone beam CT and reconstructed for computational fluid dynamics (CFD) analysis. Both steady-state and pulsatile flow conditions using the measured waveforms from the aneurysm model were studied. To reduce computational costs, we modeled the asymmetric stent effect by specifying a pressure drop over the layer across the aneurysm orifice where the low porosity patch was located. From the CFD results, we found the asymmetric stent reduced the inflow into the aneurysm by 51%, and appeared to create a stasis-like environment which favors thrombus formation. The DSA sequences also showed substantial flow reduction into the aneurysm. Asymmetric stents may be a viable image guided intervention for treating intracranial aneurysms with desired flow modification features.

  3. Air cholangiography in endoscopic bilateral stent-in-stent placement of metallic stents for malignant hilar biliary obstruction.

    PubMed

    Lee, Jae Min; Lee, Sang Hyub; Jang, Dong Kee; Chung, Kwang Hyun; Park, Jin Myung; Paik, Woo Hyun; Lee, Jun Kyu; Ryu, Ji Kon; Kim, Yong-Tae

    2016-03-01

    Although endoscopic bilateral stent-in-stent (SIS) placement of self-expandable metallic stents (SEMS) is one of the major palliative treatments for unresectable malignant hilar biliary obstruction, post-endoscopic retrograde cholangiopancreatography (ERCP) cholangitis can occur frequently due to inadequate drainage, especially after contrast injection into the biliary tree. The aim of this study is to evaluate the efficacy and safety of air cholangiography-assisted stenting. This study included 47 patients with malignant hilar biliary obstruction who underwent endoscopic bilateral SEMS placement using the SIS technique. They were divided into two groups, air (n = 23) or iodine contrast (n = 24) cholangiography. We retrospectively compared comprehensive clinical and laboratory data of both groups. There were no significant differences found between the two groups with respect to technical success (87% versus 87.5%, air versus contrast group, respectively), functional success (95% versus 95.2%), 30-day mortality (8.3% versus 8.7%) and stent patency. Post-ERCP adverse events occurred in 5 (21.7%) of the patients in the air group and 8 (33.3%) of the patients in the contrast group. Among these, the rate of cholangitis was significantly lower in the air group (4.8% versus 29.2%, p = 0.048). In multivariate analysis, air cholangiography, technical success and a shorter procedure time were significantly associated with a lower incidence of post-ERCP cholangitis. Air cholangiography-assisted stenting can be a safe and effective method for endoscopic bilateral SIS placement of SEMS in patients with malignant hilar biliary obstruction.

  4. Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).

    PubMed

    Lee, Joo Myung; Park, Kyung Woo; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon-Kwon; Bae, Jang-Whan; Woo, Sung-Il; Park, Jin Sik; Jin, Dong-Kyu; Jeon, Dong Woon; Oh, Seok Kyu; Park, Jong-Seon; Kim, Doo-Il; Hyon, Min Su; Jeon, Hui-Kyung; Lim, Do-Sun; Kim, Myeong-Gon; Rha, Seung-Woon; Her, Sung-Ho; Hwang, Jin-Yong; Kim, Sanghyun; Choi, Young Jin; Kang, Jin Ho; Moon, Keon-Woong; Jang, Yangsoo; Kim, Hyo-Soo

    2014-11-01

    Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p <0.001) and off-label indication (adjusted HR 1.782, 95% CI 1.169 to 2.718, p = 0.007) were the strongest predictors of target lesion failure at 3 years. In conclusion, both stents showed comparable safety and efficacy at 3-year follow-up in this robust real-world registry with unrestricted use of EES and ZES-R. Overall incidences of target lesion failure and definite stent thrombosis, including very late stent thrombosis, were low, even in the patients with off-label indications, suggesting excellent long-term safety and sustained efficacy of both types of second-generation drug-eluting stents. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Lower urinary tract infection and bacterial colonization in patient with double J ureteral stent.

    PubMed

    Joshi, R; Singh, D R; Sharma, S

    2011-10-01

    The aim of this study is to investigate the bacteriology of urinary tract infection associated with indwelling DJ stent. A total of 60 patients were included and 14 lost during follow up. Study period was for 6 months carried out in the department of surgery, Kathmandu Medical College. Prophylactic antibiotic was given at the time of intervention. Mid stream urine samples for routine and culture were sent before intervention. Urine samples during DJ removal and DJ tip cultures were also sent. All patients were "stented" during the various open and endourolgical procedures. Patients were clinically followed for a period till the DJ was removed. Statistical Package for Scientific Study (SPSS) 11, Chi square Test was used for statistical analysis. A total of 46 cases were included. Mean age in years was 35.70 (10-78 years). Male were 22 and female 24. Eleven patients (23.91%) had stent placed less than 30 days and 35 patients (76.08%) had it for equal or more than 30 days. DJ indwelling time was in between 12-86 days. Bacterial colonies were found in 28.3% (13 of 46) of the urine samples and 30.4% (14 of 46) from the tip of the DJ stent segment. Of the pathogens identified, E. coli was found to be the most common. An increased stent colonization rate was associated with implantation time, female sex. On urine culture 70.21% had no growth, 14.89% E. coli, 4.25% Klebsiella, Actinobacter, 2.12% E. coli/kleb, multiple org, psuedomonas. Ten patients (21.7%) had positive urine culture before stent insertion. Thirteen patients (28.3%) were shown to have positive urine culture on stent removal. Fourteen patients (30.4%) had positive DJ stent culture. Positive urine culture and positive DJ tip cultures had strong correlation. Longer duration of placement of stent showed stent colonization. The commonest pathogen was E. coli.

  6. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    PubMed

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels <3 mm in diameter. We analyzed the impact of stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; P<.001). The benefit of a DES compared to a BMS regarding ISR was consistent among the subgroups of stent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels <3.0 mm and lesions >15 mm length. © 2016 John Wiley & Sons Ltd.

  7. Integrity(®) bare-metal coronary stent-induced platelet and endothelial cell activation results in a higher risk of restenosis compared to Xience(®) everolimus-eluting stents in stable angina patients.

    PubMed

    Szük, Tibor; Fejes, Zsolt; Debreceni, Ildikó Beke; Kerényi, Adrienne; Édes, István; Kappelmayer, János; Nagy, Béla

    2016-07-01

    Drug-eluting stenting (DES) has become a reliable tool for coronary stenting; however, its direct effects on platelet and endothelium function differ from those of bare-metal stenting (BMS). This study involved a periprocedural analysis of various biomarkers of cellular activation after elective DES (Xience(®), Abbott Vascular, Santa Clara, CA, USA) or BMS (Integrity(®), Medtronic, Minneapolis, MI, USA). Forty-nine stable angina patients were recruited: 28 underwent BMS, and 21 received everolimus-eluting stents. Samples were collected (i) prior to stenting, (ii) at 24 hours after procedure, and (iii) after 1 month of dual antiplatelet therapy. Platelet activation was analyzed by surface P-selectin positivity in parallel with plasma levels of soluble P-selectin, CD40L and platelet-derived growth factor (PDGF). Endothelial cell (EC) activation was detected by measuring markers of early (von Willebrand factor) and delayed response (VCAM-1, ICAM-1, E-selectin). Patients were followed for 6 months for the occurrence of restenosis or stent thrombosis. Increased platelet activation was sustained regardless of stent type or antiplatelet medication. Concentrations of most EC markers were more elevated after BMS than after DES. No stent thrombosis was seen, but six BMS subjects displayed restenosis with significantly higher sCD40L (779 [397-899] vs. 381 [229-498] pg/mL; p = 0.032) and sICAM-1 (222 [181-272] vs. 162 [153-223] ng/mL; p = 0.046) levels than in those without complication, while DES patients exhibited significantly decreased PDGF (572 [428-626] vs. 244 [228-311] pg/mL; p = 0.004) after 1 month. Nonresponsiveness to antiplatelet drugs did not influence these changes. In conclusion, the degree of platelet and EC activation suggests that Xience(®) DES may be regarded a safer coronary intervention than Integrity(®) BMS, with a lower risk of in-stent restenosis.

  8. Stent Thrombosis in Drug-Eluting or Bare-Metal Stents in Patients Receiving Dual Antiplatelet Therapy.

    PubMed

    Kereiakes, Dean J; Yeh, Robert W; Massaro, Joseph M; Driscoll-Shempp, Priscilla; Cutlip, Donald E; Steg, P Gabriel; Gershlick, Anthony H; Darius, Harald; Meredith, Ian T; Ormiston, John; Tanguay, Jean-François; Windecker, Stephan; Garratt, Kirk N; Kandzari, David E; Lee, David P; Simon, Daniel I; Iancu, Adrian Corneliu; Trebacz, Jaroslaw; Mauri, Laura

    2015-10-01

    This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p < 0.001). DES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound.

    PubMed

    Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J

    2006-08-15

    Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.

  10. Self-expandable metallic stent as a bridge to elective surgery versus emergency surgery for acute malignant colorectal obstruction.

    PubMed

    Li, Zhi-Xiong; Wu, Xiao-Hua; Wu, Hai-yan; Chang, Wen-Ju; Chang, Xiu-juan; Yi, Tuo; Shi, Qiang; Chen, Jing-Wen; Feng, Qing-Yang; Zhu, De-Xiang; Wei, Ye; Zhong, Yun-Shi; Xu, Jian-Min

    2016-03-01

    The efficacy and safety of self-expandable metallic stents (SEMSs) as a bridge for patients with acute malignant colorectal obstructions (AMCOs) are still controversial. We conducted this study to evaluate the outcomes of patients with AMCOs treated by different strategies. From January 2010 to March 2014, a total of 171 patients with AMCOs from Zhongshan Hospital were retrospectively enrolled in this study. One hundred twenty patients successfully received stent placement followed by one-stage laparoscopic or open resection in the stent group, and 51 patients received emergency operations in the emergency group. The operation duration and postoperative hospital stay were significantly shorter in the stent group (114.51 ± 28.65 vs. 160.39 ± 58.94 min, P < 0.001; 8.00 ± 3.97 vs. 12.59 ± 9.07 days, P = 0.001). The stent group also had significantly reduced intraoperative blood loss and the incidence of postoperative complications compared with the emergency group (61.00 ± 43.70 vs. 121.18 ± 85.90 ml, P < 0.001; 16.7 vs. 37.3%, P = 0.003). Kaplan-Meier survival curves showed that the median survival time in the stent group was significantly longer than that in the emergency group (53 vs. 41 months, P = 0.034). In subgroup analysis of stent group, the stent laparoscopy group had significantly decreased postoperative complications (P = 0.025), and similar long-term survival (P = 0.81). Stent placement as a bridge to surgery is a safe and feasible procedure and provides significant advantages in terms of short-term outcomes and favorable prognoses for patients with AMCOs. Laparoscopic surgery could be considered as an optimal treatment after stent placement.

  11. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    PubMed Central

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  12. Interim analysis: A rational approach of decision making in clinical trial.

    PubMed

    Kumar, Amal; Chakraborty, Bhaswat S

    2016-01-01

    Interim analysis of especially sizeable trials keeps the decision process free of conflict of interest while considering cost, resources, and meaningfulness of the project. Whenever necessary, such interim analysis can also call for potential termination or appropriate modification in sample size, study design, and even an early declaration of success. Given the extraordinary size and complexity today, this rational approach helps to analyze and predict the outcomes of a clinical trial that incorporate what is learned during the course of a study or a clinical development program. Such approach can also fill the gap by directing the resources toward relevant and optimized clinical trials between unmet medical needs and interventions being tested currently rather than fulfilling only business and profit goals.

  13. Can the optimal type of stent be predicted based on clinical risk factors? A subgroup analysis of the randomized BASKET-PROVE trial.

    PubMed

    Vassalli, Giuseppe; Klersy, Catherine; De Servi, Stefano; Galatius, Soeren; Erne, Paul; Eberli, Franz; Rickli, Hans; Hornig, Burkhard; Bertel, Osmund; Bonetti, Piero; Moccetti, Tiziano; Kaiser, Christoph; Pfisterer, Matthias; Pedrazzini, Giovanni

    2016-03-01

    The randomized BASKET-PROVE study showed no significant differences between sirolimus-eluting stents (SES), everolimus-eluting stents (EES), and bare-metal stents (BMS) with respect to the primary end point, rates of death from cardiac causes, or myocardial infarction (MI) at 2 years of follow-up, in patients requiring stenting of a large coronary artery. Clinical risk factors may affect clinical outcomes after percutaneous coronary interventions. We present a retrospective analysis of the BASKET-PROVE data addressing the question as to whether the optimal type of stent can be predicted based on a cumulative clinical risk score. A total of 2,314 patients (mean age 66 years) who underwent coronary angioplasty and implantation of ≥1 stents that were ≥3.0 mm in diameter were randomly assigned to receive SES, EES, or BMS. A cumulative clinical risk score was derived using a Cox model that included age, gender, cardiovascular risk factors (hypercholesterolemia, hypertension, family history of cardiovascular disease, diabetes, smoking), presence of ≥2 comorbidities (stroke, peripheral artery disease, chronic kidney disease, chronic rheumatic disease), a history of MI or coronary revascularization, and clinical presentation (stable angina, unstable angina, ST-segment elevation MI). An aggregate drug-eluting stent (DES) group (n = 1,549) comprising 775 patients receiving SES and 774 patients receiving EES was compared to 765 patients receiving BMS. Rates of death from cardiac causes or nonfatal MI at 2 years of follow-up were significantly increased in patients who were in the high tertile of risk stratification for the clinical risk score compared to those who were in the aggregate low-mid tertiles. In patients with a high clinical risk score, rates of death from cardiac causes or nonfatal MI were lower in patients receiving DES (2.4 per 100 person-years, 95% CI 1.6-3.6) compared with BMS (5.5 per 100 person-years, 95% CI 3.7-8.2, hazard ratio 0.45, 95% CI 0.26-0.80, P = .007). However, they were not significantly different between receivers of DES and BMS in patients in the low-mid risk tertiles. This exploratory analysis suggests that, in patients who require stenting of a large coronary artery, use of a clinical risk score may identify those patients for whom DES use may confer a clinical advantage over BMS, beyond lower restenosis rates. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. CT-based texture analysis potentially provides prognostic information complementary to interim fdg-pet for patients with hodgkin's and aggressive non-hodgkin's lymphomas.

    PubMed

    Ganeshan, B; Miles, K A; Babikir, S; Shortman, R; Afaq, A; Ardeshna, K M; Groves, A M; Kayani, I

    2017-03-01

    The purpose of this study was to investigate the ability of computed tomography texture analysis (CTTA) to provide additional prognostic information in patients with Hodgkin's lymphoma (HL) and high-grade non-Hodgkin's lymphoma (NHL). This retrospective, pilot-study approved by the IRB comprised 45 lymphoma patients undergoing routine 18F-FDG-PET-CT. Progression-free survival (PFS) was determined from clinical follow-up (mean-duration: 40 months; range: 10-62 months). Non-contrast-enhanced low-dose CT images were submitted to CTTA comprising image filtration to highlight features of different sizes followed by histogram-analysis using kurtosis. Prognostic value of CTTA was compared to PET FDG-uptake value, tumour-stage, tumour-bulk, lymphoma-type, treatment-regime, and interim FDG-PET (iPET) status using Kaplan-Meier analysis. Cox regression analysis determined the independence of significantly prognostic imaging and clinical features. A total of 27 patients had aggressive NHL and 18 had HL. Mean PFS was 48.5 months. There was no significant difference in pre-treatment CTTA between the lymphoma sub-types. Kaplan-Meier analysis found pre-treatment CTTA (medium feature scale, p=0.010) and iPET status (p<0.001) to be significant predictors of PFS. Cox analysis revealed that an interaction between pre-treatment CTTA and iPET status was the only independent predictor of PFS (HR: 25.5, 95% CI: 5.4-120, p<0.001). Specifically, pre-treatment CTTA risk stratified patients with negative iPET. CTTA can potentially provide prognostic information complementary to iPET for patients with HL and aggressive NHL. • CT texture-analysis (CTTA) provides prognostic information complementary to interim FDG-PET in Lymphoma. • Pre-treatment CTTA and interim PET status were significant predictors of progression-free survival. • Patients with negative interim PET could be further stratified by pre-treatment CTTA. • Provide precision surveillance where additional imaging reserved for patients at greatest recurrence-risk. • Assists in risk-adapted treatment strategy based on interim PET and CTTA.

  15. Radioactive self-expanding stents for palliative management of unresectable esophageal cancer: a systematic review and meta-analysis.

    PubMed

    Chen, Hong-Lin; Shen, Wang-Qin; Liu, Kun

    2017-05-01

    Stent insertion is a feasible and safe palliative management for advanced unresectable esophageal cancer. The aim of this study is to assess the efficacy of radioactive stent for unresectable esophageal cancer compared with conventional stent. Systematic searches of the PubMed and Web of science are dated from their beginning to January 25, 2016. Studies that compared radioactive stent with conventional stent for unresectable esophageal cancer were included. The outcomes were postimplantation survival, relief of dysphagia, and complications related to stent implant. Six studies with 539 patients were included. All of them used stent equipped with radioactive iodine beads as a radioactive stent. The pooled weighted mean difference for median survival was 2.734 months (95% CI 1.710-3.775; Z = 5.21, P = 0.000) between two groups. The 1,3,6 month survival rates were higher in radioactive stents than conventional stent, with the pooled ORs 3.216 (95% CI 1.293-7.999; Z = 2.51, P = 0.012), 3.095 (95% CI 1.908-5.020; Z = 4.58, P = 0.000), and 7.503 (95% CI 2.206- 25.516; Z = 3.23, P = 0.001, respectively). The pooled hazard ratio was 0.464 (95% CI 0.328-0.655; Z = 4.35, P = 0.000) between two groups. For relief of dysphagia, two stents all have good relief of the dysphagia effect, but radioactive stent showed a better effect at 3, 6 months follow-up after implantation. For complications related to stent implant, no significant differences were found between two stents in terms of severe chest pain (30.0% vs. 35.7%, OR 0.765, 95% CI 0.490-1.196), gastroesophageal reflux (18.6% vs. 16.1%, OR 1.188, 95% CI 0.453-3.115), fever (12.1% vs. 12.1%, OR 1.014, 95% CI 0.332-3.097), bleeding (16.7% vs. 14.2%, OR 1.201, 95% CI 0.645-2.236), perforation or fistula (6.1% vs. 9.0%, OR 0.658, 95% CI 0.291-1.486), pneumonia (10.7% vs. 14.1%, OR 0.724, 95% CI 0.343-1.526), stent migration (7.0% vs. 10.2%, OR 0.651, 95% CI 0.220-1.924), and restenosis (24.2% vs. 20.6%, OR 1.228, 95% CI 0.674-2.239). Radioactive stent insertion had potential benefits for palliative management for patients with unresectable esophageal cancer. This method prolonged survival and dysphagia relief period without more complications. However, this conclusion should be confirmed by more trials. © International Society for Diseases of the Esophagus 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention.

    PubMed

    Baschet, Louise; Bourguignon, Sandrine; Marque, Sébastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117 762 patient-years with 76 randomised trials. The main effectiveness criterion was major cardiac event-free survival. Effectiveness and costs were modelled over a 5-year horizon using a three-state Markov model. Incremental cost-effectiveness ratios and a cost-effectiveness acceptability curve were calculated for a range of thresholds for willingness to pay per year without major cardiac event gain. Deterministic and probabilistic sensitivity analyses were performed. Base case results demonstrated that DES are dominant over BMS, with an increase in event-free survival and a cost-reduction of €184, primarily due to a diminution of second revascularisations, and an absence of myocardial infarction and stent thrombosis. These results are robust for uncertainty on one-way deterministic and probabilistic sensitivity analyses. Using a cost-effectiveness threshold of €7000 per major cardiac event-free year gained, DES has a >95% probability of being cost-effective versus BMS. Following DES price decrease, new-generation DES development and taking into account recent meta-analyses results, the DES can now be considered cost-effective regardless of selective indication in France, according to European recommendations.

  17. Reduction of In-Stent Restenosis Risk on Nickel-Free Stainless Steel by Regulating Cell Apoptosis and Cell Cycle

    PubMed Central

    Li, Liming; Pan, Shuang; Zhou, Xiaohang; Meng, Xin; Han, Xiaoxi; Ren, Yibin; Yang, Ke; Guan, Yifu

    2013-01-01

    High nitrogen nickel-free austenitic stainless steel (HNNF SS) is one of the biomaterials developed recently for circumventing the in-stent restenosis (ISR) in coronary stent applications. To understand the ISR-resistance mechanism, we have conducted a comparative study of cellular and molecular responses of human umbilical vein endothelial cells (HUVECs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel) which is the stent material used currently. CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profile of HUVECs exposed to HNNF SS and 316L SS, respectively. Flow cytometry analysis revealed that 316L SS could activate the cellular apoptosis more efficiently and initiate an earlier entry into the S-phase of cell cycle than HNNF SS. At the molecular level, qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were overexpressed on 316L SS. Further examination indicated that nickel released from 316L SS triggered the cell apoptosis via Fas-Caspase8-Caspase3 exogenous pathway. These molecular mechanisms of HUVECs present a good model for elucidating the observed cellular responses. The findings in this study furnish valuable information for understanding the mechanism of ISR-resistance on the cellular and molecular basis as well as for developing new biomedical materials for stent applications. PMID:23638002

  18. Automatic quantitative analysis of in-stent restenosis using FD-OCT in vivo intra-arterial imaging.

    PubMed

    Mandelias, Kostas; Tsantis, Stavros; Spiliopoulos, Stavros; Katsakiori, Paraskevi F; Karnabatidis, Dimitris; Nikiforidis, George C; Kagadis, George C

    2013-06-01

    A new segmentation technique is implemented for automatic lumen area extraction and stent strut detection in intravascular optical coherence tomography (OCT) images for the purpose of quantitative analysis of in-stent restenosis (ISR). In addition, a user-friendly graphical user interface (GUI) is developed based on the employed algorithm toward clinical use. Four clinical datasets of frequency-domain OCT scans of the human femoral artery were analyzed. First, a segmentation method based on fuzzy C means (FCM) clustering and wavelet transform (WT) was applied toward inner luminal contour extraction. Subsequently, stent strut positions were detected by utilizing metrics derived from the local maxima of the wavelet transform into the FCM membership function. The inner lumen contour and the position of stent strut were extracted with high precision. Compared to manual segmentation by an expert physician, the automatic lumen contour delineation had an average overlap value of 0.917 ± 0.065 for all OCT images included in the study. The strut detection procedure achieved an overall accuracy of 93.80% and successfully identified 9.57 ± 0.5 struts for every OCT image. Processing time was confined to approximately 2.5 s per OCT frame. A new fast and robust automatic segmentation technique combining FCM and WT for lumen border extraction and strut detection in intravascular OCT images was designed and implemented. The proposed algorithm integrated in a GUI represents a step forward toward the employment of automated quantitative analysis of ISR in clinical practice.

  19. A recoil resilient lumen support, design, fabrication and mechanical evaluation

    NASA Astrophysics Data System (ADS)

    Mehdizadeh, Arash; Ali, Mohamed Sultan Mohamed; Takahata, Kenichi; Al-Sarawi, Said; Abbott, Derek

    2013-06-01

    Stents are artificial implants that provide scaffolding to a cavity inside the body. This paper presents a new luminal device for reducing the mechanical failure of stents due to recoil, which is one of the most important issues in stenting. This device, which we call a recoil-resilient ring (RRR), is utilized standalone or potentially integrated with existing stents to address the problem of recoil. The proposed structure aims to minimize the need for high-pressure overexpansion that can induce intra-luminal trauma and excess growth of vascular tissue causing later restenosis. The RRR is an overlapped open ring with asymmetrical sawtooth structures that are intermeshed. These teeth can slide on top of each other, while the ring is radially expanded, but interlock step-by-step so as to keep the final expanded state against compressional forces that normally cause recoil. The RRRs thus deliver balloon expandability and, when integrated with a stent, bring both radial rigidity and longitudinal flexibility to the stent. The design of the RRR is investigated through finite element analysis (FEA), and then the devices are fabricated using micro-electro-discharge machining of 200-µm-thick Nitinol sheet. The standalone RRR is balloon expandable in vitro by 5-7 Atm in pressure, which is well within the recommended in vivo pressure ranges for stenting procedures. FEA compression tests indicate 13× less reduction of the cross-sectional area of the RRR compared with a typical stainless steel stent. These results also show perfect elastic recovery of the RRR after removal of the pressure compared to the remaining plastic deformations of the stainless steel stent. On the other hand, experimental loading tests show that the fabricated RRRs have 2.8× radial stiffness compared to a two-column section of a commercial stent while exhibiting comparable elastic recovery. Furthermore, testing of in vitro expansion in a mock artery tube shows around 2.9% recoil, approximately 5-11× smaller than the recoil reported for commercial stents. These experimental results demonstrate the effectiveness of the device design for the targeted luminal support and stenting applications.

  20. Impact of biliary stents on EUS-guided FNA of pancreatic mass lesions

    PubMed Central

    Ranney, Nathaniel; Phadnis, Milind; Trevino, Jessica; Ramesh, Jayapal; Wilcox, C. Mel; Varadarajulu, Shyam

    2014-01-01

    Background Few studies have evaluated the impact of biliary stents on EUS-guided FNA. Aim To compare diagnostic yield of EUS-FNA in patients with or without biliary stents. Design Retrospective study. Setting Tertiary referral center. Patients Patients with obstructive jaundice secondary to solid pancreatic mass lesions who underwent EUS-FNA over 5 years. Main Outcome Measures The primary objective was to compare the diagnostic accuracy of EUS-FNA in patients with or without biliary stents and between patients with plastic stents or self-expandable metal stents (SEMSs). Secondary objectives were to assess the technical difficulty of EUS-FNA by comparing the number of passes required to establish diagnosis and to identify predictors of a false-negative diagnosis. Results Of 214 patients who underwent EUS-FNA, 150 (70%) had biliary stents and 64 (30%) had no stents in place. Of 150 patients with biliary stents, 105 (70%) were plastic and 45 (30%) were SEMSs. At EUS-FNA, the diagnosis was pancreatic cancer in 155 (72%), chronic pancreatitis in 17 (8%), other cancer in 31 (14%), and indeterminate in 11 (5%). There was no difference in rates of diagnostic accuracy between patients with or without stents (93.7% vs 95.3%; P = .73) and between plastic or SEMSs (95.2% vs 95.5%, P = .99), respectively. Median number of passes to diagnosis was not significantly different between patients with or without stents (2 [interquartile ratio range (IQR) = 1–3] vs 2 [IQR = 1–4]; P = .066) and between plastic or SEMS (2.5 [IQR = 1–4] vs 2 [IQR = 1–4], P = .69), respectively. On univariate analysis, EUS-FNA results were false-negative in patients with large pancreatic masses (>3 cm vs <3 cm, 9.35% vs 0.93%, P = .005) that required more FNA passes (<2 vs >2 passes, 0% vs 11.8%, P < .0001). Limitations Retrospective study. Conclusions The presence or absence of a biliary stent, whether plastic or metal, does not have an impact on the diagnostic yield or technical difficulty of EUS-FNA. PMID:22726468

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Cheng-Hung; Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan; Jhong, Guan-Heng

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force followingmore » stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.« less

  2. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    PubMed

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Bethany H. T., E-mail: bmiller@doctors.org.uk; Griffiths, Ewen A., E-mail: Eagriffiths@doctors.org.uk; Pursnani, Kishore G., E-mail: Kish.Pursnani@lthtr.nhs.uk

    2013-12-15

    IntroductionSelf-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients' case notes. Univariate survival analysis was performed. Results: Between December 2000 andmore » January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39-89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1-624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.« less

  4. Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature.

    PubMed

    King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J

    2015-12-01

    The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (p<0.001), ICH (p=0.001), mortality among all patients (p=0.03), and recanalization (p=0.02) were more commonly reported in NEU treated aneurysms. The ENT system was also associated with higher reported complete occlusion at follow-up (p<0.001). This literature review represents the largest and most robust comparison of stent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.

    PubMed

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.

  6. Evaluation of the Effects of Temporary Covered Nitinol Stent Placement in the Prostatic Urethra: Short-Term Study in the Canine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crisostomo, Veronica; Song, Ho Young; Maynar, Manuel

    Purpose. To evaluate the effect of temporary stent placement on the canine prostatic urethra. Methods. Retrievable PTFE-covered nitinol stents were placed in the prostatic urethras of 8 beagle dogs under fluoroscopic guidance. Retrograde urethrography was obtained before and after stenting. Retrograde urethrography and endoscopy were performed 1 and 2 months after deployment. The endoscopic degree of hyperplasia was rated on a scale of 0 to 4 (0 absence, 4 = occlusion). On day 60, stents were removed and urethrography was performed immediately before euthanasia. Pathologic analysis was performed to determine the degree of glandular atrophy, periurethral fibrosis, and urethral dilation.more » Results. Stent deployment was technically successful in 7 animals, and failed in 1 dog due to a narrow urethral lumen. Complete migration was seen in 2 animals at 1 month, and an additional stent was deployed. On day 30, endoscopy showed slight hyperplasia (grade 1) in 3 animals. On day 60, moderate hyperplasia (grade 2) was evidenced in 4 cases. No impairment of urinary flow was seen during follow-up. Retrieval was technically easy to perform, and was successful in all dogs. The major histologic findings were chronic inflammatory cell infiltrates; prostate glandular atrophy, with a mean value of 1.86 (SD 0.90); periurethral fibrosis, with a mean ratio of 29.37 (SD 10.41); and dilatation of the prostatic urethra, with a mean ratio of 6.75 (SD 3.22). Conclusion. Temporary prostatic stent placement in dogs is safe and feasible, causing marked enlargement of the prostatic urethral lumen. Retrievable covered stents may therefore be an option for bladder outlet obstruction management in men.« less

  7. Endoscopic removal of malfunctioning biliary self-expandable metallic stents.

    PubMed

    Familiari, Pietro; Bulajic, Milutin; Mutignani, Massimiliano; Lee, Linda S; Spera, Gianluca; Spada, Cristiano; Tringali, Andrea; Costamagna, Guido

    2005-12-01

    Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal.

  8. Evaluation of Angiographic and Technical Aspects of Carotid Stenting with Diffusion-Weighted Magnetic Resonance Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blasel, Stella, E-mail: Stella.Blasel@kgu.de; Hattingen, Elke; Berkefeld, Joachim

    2009-07-15

    The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe ({>=}60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions,more » with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-{mu}m vs. 110-120-{mu}m pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.« less

  9. Endoscopic guided single self-linking silicone stent in pediatric external dacryocystorhinostomy.

    PubMed

    Ali, Mohammad Javed; Gupta, Himika; Naik, Milind N; Honavar, Santosh G

    2013-09-01

    To study the efficacy of a new technique of single self-linking silicone stent exclusively in pediatric external dacryocystorhinostomy (DCR) and to report the new use and advantages of endoscopic guidance for the same. Prospective interventional case series, including 11 eyes of ten patients with nasolacrimal duct obstruction. Data collected included demographic data, clinical presentation, laterality, status of lids and puncta, syringing findings, probing interpretations, types and duration of intubation. Consecutive pediatric patients with post-saccal obstruction who underwent an external dacryocystorhinostomy were included. Exclusion criteria included patients who had undergone a DCR in the past by any route via external, endonasal or transcanalicular. Primary outcome measures were stent retention and ease of stent removal. Secondary outcome measures were anatomic patency of the passage and resolution of symptoms. There were three male and seven female patients. Mean age was 9.4 years (range 6-15). A total of 11 procedures were carried out. Following placement of self-linked stents, the removal was done at a mean duration of 13.2 weeks (range:12-16 weeks). None of the patients had a stent prolapse during this period. All stents were removed in the outpatient without the use of general anesthesia with minimal endoscopic guidance. A minimum follow-up of three months following removal was considered for final analysis. Follow-up ranged from three months to six months after tube removal. The anatomical and functional success rate was 91%. There was one anatomical failure three months following tube removal and the remaining patients were free of symptoms at the last follow-up. Self-linking stents are a useful modality in pediatric patients not only to prevent stent prolapse but also to allow easy removal with minimum discomfort. Endoscopic guidance is a useful addition to this technique.

  10. Combining clinical and angiographic variables for estimating risk of target lesion revascularization after drug eluting stent placement.

    PubMed

    Stolker, Joshua M; Cohen, David J; Kennedy, Kevin F; Pencina, Michael J; Arnold, Suzanne V; Kleiman, Neal S; Spertus, John A

    Drug-eluting stents (DES) reduce restenosis but require prolonged antiplatelet therapy, when compared with bare metal stents. Ideally, the patient should be involved in this risk:benefit assessment prior to selecting DES, to maximize the benefits and cost-effectiveness of care, and to improve medication adherence. However, accurate estimation of restenosis risk may require angiographic factors identified at cardiac catheterization. In a large PCI registry, we used logistic regression to identify clinical and angiographic predictors of clinically-driven target lesion revascularization (TLR) over the first year after stent placement. Discrimination c-statistic and integrated discrimination improvement (IDI) were used to calculate the incremental utility of angiographic variables when added to clinical predictors. Of 8501 PCI patients, TLR occurred in 4.5%. After adjusting for DES use, clinical TLR predictors were younger age, female sex, diabetes, prior PCI, and prior bypass surgery (model c-statistic 0.630). Angiographic predictors were vein graft PCI, in-stent restenosis lesion, longer stent length, and smaller stent diameter (c-statistic 0.650). After adding angiographic factors to the clinical model, c-statistic improved to 0.680 and the average separation in TLR risk among patients with and without TLR improved by 1% (IDI=0.010, 95% CI 0.009-0.014), primarily driven by those experiencing TLR (from 5.9% to 6.9% absolute risk). Among unselected PCI patients, the incidence of clinically-indicated TLR is <5% at 1-year, and standard clinical variables only moderately discriminate who will and will not experience TLR. Angiographic variables significantly improve TLR risk assessment, suggesting that stent selection may be best performed after coronary anatomy has been delineated. Although several recent studies have challenged traditional expectations regarding the duration of dual antiplatelet therapy, current guidelines recommend at least 6 to 12months of treatment after implantation of a drug eluting stent, with a shorter course for bare metal stents. Stent selection ideally should involve input from the patient receiving these stents, but multiple studies have suggested that angiographic factors - obtained after the patient has received sedation during the diagnostic catheterization - are important predictors of repeat revascularization. In this analysis from a large registry of patients receiving coronary stents, angiographic characteristics were found to significantly improve risk assessment for target lesion revascularization, when added to clinical variables alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.

    PubMed

    Liu, Yanhui; Zhu, Guoqing; Yang, Huazhe; Wang, Conger; Zhang, Peihua; Han, Guangting

    2018-01-01

    This paper presents a study of the bending flexibility of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body. To investigate the relationship between the bending load and structure parameter (monofilament diameter and braid-pin number), biodegradable polydioxanone biliary stents derived from braiding method were covered with membrane prepared via electrospinning method, and nine FCBPBSs were then obtained for bending test to evaluate the bending flexibility. In addition, by the finite element method, nine numerical models based on actual biliary stent were established and the bending load was calculated through the finite element method. Results demonstrate that the simulation and experimental results are in good agreement with each other, indicating that the simulation results can be provided a useful reference to the investigation of biliary stents. Furthermore, the stress distribution on FCBPBSs was studied, and the plastic dissipation analysis and plastic strain of FCBPBSs were obtained via the bending simulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. [Carotid Stenting in France after the EVA 3S and SPACE publications].

    PubMed

    Beyssen, B; Rousseau, H; Bracard, S; Sapoval, M; Gaux, J-C

    2007-01-01

    Angioplasty of stenoses of the carotid bifurcation is a revascularization procedure that is used successfully in many patients. With more than 10 years of experience now, the feasibility of carotid stenting has been demonstrated. Its distribution is highly variable depending on the country, with a mean penetration rate in Europe of 15% of the number of carotid revascularizations. However, the complication rate is highly variable from one series to another and depends on the type of patient treated and the operator's learning curve. The results of the first two randomized studies comparing endarterectomy and carotid stenting, EVA 3S in France and SPACE in Germany, have just been published. The conclusions of these studies only relate to symptomatic patients, who make up a small proportion of revascularized patients. At 30 days, the French study concluded that surgery was better, and the German study showed no advantage to stenting. The analysis of these results compared to other publications should make it possible to best define the current indications for carotid stenting.

  13. Age modifies the relative risk of stenting versus endarterectomy for symptomatic carotid stenosis--a pooled analysis of EVA-3S, SPACE and ICSS.

    PubMed

    Bonati, L H; Fraedrich, G

    2011-02-01

    Recent randomised controlled trials comparing carotid artery stenting (CAS) with endarterectomy (CEA) for the treatment of symptomatic carotid stenosis were not powered to investigate differences in risks in specific patient subgroups. We therefore performed a pooled analysis of individual patient data from the Symptomatic Severe Carotid Stenosis trial (EVA-3S), the Stent-Protected Angioplasty versus Carotid Endarterectomy trial (SPACE), and the International Carotid Stenting Study (ICSS). Individual data from all 3433 patients randomised and analysed in these trials were pooled and analysed with fixed-effect binomial regression models adjusted for source trial. The primary outcome event was any stroke or death. In the first 120 days after randomisation (ITT analysis), the primary outcome event occurred in 153/1725 patients in the CAS group (8.9%) compared with 99/1708 patients in the CEA group (5.8%, risk ratio [RR] 1.53, 95% confidence interval [CI] 1.20-1.95, p = 0.0006; absolute risk difference 3.2, 95% CI 1.4-4.9). Age was the only subgroup variable which significantly modified the treatment effect: in patients <70 years old (the median age), the 120-day stroke or death risk was 5.8% in CAS and 5.7% in CEA (RR 1.00, 0.68-1.47); in patients 70 years or older, there was an estimated two-fold increase in risk with CAS over CEA (12.0% vs. 5.9%, RR 2.04, 1.48-2.82, interaction p = 0.0053). Endarterectomy was safer in the short-term than stenting, because of an increased risk of stroke associated with stenting in patients over the age of 70 years. Stenting should be avoided in older patients, but may be as safe as endarterectomy in younger patients. Determination of the efficacy and ultimate balance between the two procedures requires further data on long-term stroke recurrence. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Nanomedicine for the reduction of the thrombogenicity of stent coatings

    PubMed Central

    Karagkiozaki, Varvara C; Logothetidis, Stergios D; Kassavetis, Spyridon N; Giannoglou, George D

    2010-01-01

    The treatment of patients with drug-eluting stents (DES) continues to evolve with the current emergence of DES technology that offers a combination of pharmacological and mechanical approaches to prevent arterial restenosis. However, despite the promising short-term and mid-term outcomes of DES, there are valid concerns about adverse clinical effects of late stent thrombosis. In this study, we present an example of how nanomedicine can offer solutions for improving stent coating manufacturing, by producing nanomaterials with tailored and controllable properties. The study is based on the exploitation of human platelets response towards carbon-based nanocoatings via atomic force microscope (AFM). AFM can facilitate the comprehensive analysis of platelets behavior onto stent nanocoatings and enable the study of thrombogenicity. Platelet-rich plasma from healthy donors was used for the real-time study of biointerfacial interactions. The carbon nanomaterials were developed by rf magnetron sputtering technique under controllable deposition conditions to provide favorable surface nanotopography. It was shown that by altering the surface topography of nanocoatings, the activation of platelets can be affected, while the carbon nanocoatings having higher surface roughness were found to be less thrombogenic in terms of platelets adhesion. This is an actual solution for improving the stent coating fabrication. PMID:20463940

  15. Effects of antibacterial nanostructured composite films on vascular stents: hemodynamic behaviors, microstructural characteristics, and biomechanical properties.

    PubMed

    Cheng, Han-Yi; Hsiao, Wen-Tien; Lin, Li-Hsiang; Hsu, Ya-Ju; Sinrang, Andi Wardihan; Ou, Keng-Liang

    2015-01-01

    The purpose of this research was to investigate stresses resulting from different thicknesses and compositions of hydrogenated Cu-incorporated diamond-like carbon (a-C:H/Cu) films at the interface between vascular stent and the artery using three-dimensional reversed finite element models (FEMs). Blood flow velocity variation in vessels with plaques was examined by angiography, and the a-C:H/Cu films were characterized by transmission electron microscopy to analyze surface morphology. FEMs were constructed using a computer-aided reverse design system, and the effects of antibacterial nanostructured composite films in the stress field were investigated. The maximum stress in the vascular stent occurred at the intersections of net-like structures. Data analysis indicated that the stress decreased by 15% in vascular stents with antibacterial nanostructured composite films compared to the control group, and the stress decreased with increasing film thickness. The present results confirmed that antibacterial nanostructured composite films improve the biomechanical properties of vascular stents and release abnormal stress to prevent restenosis. The results of the present study offer the clinical benefit of inducing superior biomechanical behavior in vascular stents. © 2014 Wiley Periodicals, Inc.

  16. Accounting for interim safety monitoring of an adverse event upon termination of a clinical trial.

    PubMed

    Dallas, Michael J

    2008-01-01

    Upon termination of a clinical trial that uses interim evaluations to determine whether the trial can be stopped, a proper statistical analysis must account for the interim evaluations. For example, in a group-sequential design where the efficacy of a treatment regimen is evaluated at interim stages, and the opportunity to stop the trial based on positive efficacy findings exists, the terminal p-value, point estimate, and confidence limits of the outcome of interest must be adjusted to eliminate bias. While it is standard practice to adjust terminal statistical analyses due to opportunities to stop for "positive" findings, adjusting due to opportunities to stop for "negative" findings is also important. Stopping rules for negative findings are particularly useful when monitoring a specific rare serious adverse event in trials designed to show safety with respect to the event. In these settings, establishing conservative stopping rules are appropriate, and therefore accounting for the interim monitoring can have a substantial effect on the final results. Here I present a method to account for interim safety monitoring and illustrate its usefulness. The method is demonstrated to have advantages over methodology that does not account for interim monitoring.

  17. A Meta-Analysis of the Effect of Preoperative Biliary Stenting on Patients With Obstructive Jaundice

    PubMed Central

    Sun, Chengyi; Yan, Guirong; Li, Zhiming; Tzeng, Chi-Meng

    2014-01-01

    Abstract The goal of this study was to systematically review the effects of biliary stenting on postoperative morbidity and mortality of patients with obstructive jaundice. PubMed, Embase, Cochrane Library, and other relevant databases were searched by computer and manually for published and unpublished studies on the impact of preoperative biliary drainage on patients with obstructive jaundice from 2000 to the present day. Two investigators independently selected the studies according to the inclusion and exclusion criteria, extracted the data, and assessed the quality of the selected studies. Meta-analysis was performed to compare postoperative morbidity and mortality of patients between the drainage and nondrainage groups. Compared with the nondrainage group, the overall mortality, overall morbidity, infectious morbidity, incidence of wound infection, intra-abdominal abscess, pancreatic fistulas, bile leak, and delayed gastric emptying in the drainage group were not significantly different. Compared with the nondrainage group, the drainage group had a drainage time of <4 weeks with an increased overall morbidity by 7% to 23%; however, the overall morbidity of the drainage group with a drainage time >4 weeks was not significantly different. Compared with the nondrainage group, the overall mortality of the drainage group using metal stents and plastic stents as internal drainage devices was reduced by 0.5% to 6%, whereas that of the drainage group using plastic stent devices was not significantly different. In summary, preoperative drainage should be applied selectively. The drainage time should be >4 weeks, and metal stents should be used for internal drainage. PMID:25474436

  18. Cost-effectiveness analysis of biodegradable polymer versus durable polymer drug-eluting stents incorporating real-world evidence.

    PubMed

    Teng, Monica; Zhao, Ying Jiao; Khoo, Ai Leng; Ananthakrishna, Rajiv; Yeo, Tiong Cheng; Lim, Boon Peng; Chan, Mark Y; Loh, Joshua P

    2018-06-05

    Compared with second-generation durable polymer drug-eluting stents (DP-DES), the cost-effectiveness of biodegradable polymer drug-eluting stents (BP-DES) remains unclear in the real-world setting. We assessed the cost-effectiveness of BP-DES in patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We developed a decision-analytic model to compare the cost-effectiveness of BP-DES to DP-DES over one year and five years from healthcare payer perspective. Relative treatment effects during the first year post-PCI were obtained from a real-world population analysis while clinical event risks in the subsequent four years were derived from a meta-analysis of published studies. At one year, based on the clinical data analysis of 497 propensity-score matched pairs of patients, BP-DES were associated with an incremental cost-effectiveness ratio (ICER) of USD20,503 per quality-adjusted life-year (QALY) gained. At five years, BP-DES yielded an ICER of USD4,062 per QALY gained. At the willingness-to-pay threshold of USD50,400 (one gross domestic product per capita in Singapore in 2015), BP-DES were cost-effective. Sensitivity analysis showed that the cost of stents had a significant impact on the cost-effectiveness of BP-DES. Threshold analysis demonstrated that if the cost difference between BP-DES and DP-DES exceeded USD493, BP-DES would not be cost-effective in patients with one-year of follow-up. BP-DES were cost-effective compared with DP-DES in patients with coronary artery disease at one year and five years after PCI. It is worth noting that the cost of stents had a significant impact on the findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Surface modification of endovascular stents with rosuvastatin and heparin-loaded biodegradable nanofibers by electrospinning.

    PubMed

    Janjic, Milka; Pappa, Foteini; Karagkiozaki, Varvara; Gitas, Christakis; Ktenidis, Kiriakos; Logothetidis, Stergios

    2017-01-01

    This study describes the development of drug-loaded nanofibrous scaffolds as a nanocoating for endovascular stents for the local and sustained delivery of rosuvastatin (Ros) and heparin (Hep) to injured artery walls after endovascular procedures via the electrospinning process. The proposed hybrid covered stents can promote re-endothelialization; improve endothelial function; reduce inflammatory reaction; inhibit neointimal hyperplasia of the injured artery wall, due to well-known pleiotropic actions of Ros; and prevent adverse events such as in-stent restenosis (ISR) and stent thrombosis (ST), through the antithrombotic action of Hep. Biodegradable nanofibers were prepared by dissolving cellulose acetate (AC) and Ros in N , N -dimethylacetamide (DMAc) and acetone-based solvents. The polymeric solution was electrospun (e-spun) into drug-loaded AC nanofibers onto three different commercially available stents (Co-Cr stent, Ni-Ti stent, and stainless steel stent), resulting in nonwoven matrices of submicron-sized fibers. Accordingly, Hep solution was further used for fibrous coating onto the engineered Ros-loaded stent. The functional encapsulation of Ros and Hep drugs into polymeric scaffolds further underwent physicochemical analysis. Morphological characterization took place via scanning electron microscopy (SEM) and atomic force microscopy (AFM) analyses, while scaffolds' wettability properties were obtained by contact angle (CA) measurements. The morphology of the drug-loaded AC nanofibers was smooth, with an average diameter of 200-800 nm, and after CA measurement, we concluded to the superhydrophobic nature of the engineered scaffolds. In vitro release rates of the pharmaceutical drugs were determined using a high-performance liquid chromatography assay, which showed that after the initial burst, drug release was controlled slowly by the degradation of the polymeric materials. These results imply that AC nanofibers encapsulated with Ros and Hep drugs have great potential in the development of endovascular grafts with anti-thrombogenic properties that can accelerate the re-endothelialization, reduce the neointimal hyperplasia and inflammatory reaction, and improve the endothelial function.

  20. Optimal radial force and size for palliation in gastroesophageal adenocarcinoma: a comparative analysis of current stent technology.

    PubMed

    Mbah, Nsehniitooh; Philips, Prejesh; Voor, Michael J; Martin, Robert C G

    2017-12-01

    The optimal use of esophageal stents for malignant and benign esophageal strictures continues to be plagued with variability in pain tolerance, migration rates, and reflux-related symptoms. The aim of this study was to evaluate the differences in radial force exhibited by a variety of esophageal stents with respect to the patient's esophageal stricture. Radial force testing was performed on eight stents manufactured by four different companies using a hydraulic press and a 5000 N force gage. Radial force was measured using three different tests: transverse compression, circumferential compression, and a three-point bending test. Esophageal stricture composition and diameters were measured to assess maximum diameter, length, and proximal esophageal diameter among 15 patients prior to stenting. There was a statistically significant difference in mean radial force for transverse compression tests at the middle (range 4.25-0.66 newtons/millimeter N/mm) and at the flange (range 3.32-0.48 N/mm). There were also statistical differences in mean radial force for circumferential test (ranged from 1.19 to 10.50 N/mm, p < 0.001) and the three-point bending test (range 0.08-0.28 N/mm, p < 0.001). In an evaluation of esophageal stricture diameters and lengths, the smallest median diameter of the stricture was 10 mm (range 5-16 mm) and the median proximal diameter normal esophagus was 25 mm (range 22-33 mm), which is currently outside of the range of stent diameters. Tested stents demonstrated significant differences in radial force, which provides further clarification of stent pain and intolerance in certain patients, with either benign or malignant disease. Similarly, current stent diameters do not successfully exclude the proximal esophagus, which can lead to obstructive-type symptoms. Awareness of radial force, esophageal stricture composition, and proximal esophageal diameter must be known and understood for optimal stent tolerance.

  1. Distal Embolization After Stenting of the Vertebral Artery: Diffusion-Weighted Magnetic Resonance Imaging Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canyigit, Murat; Arat, Anil; Cil, Barbaros E.

    2007-04-15

    Purpose. We retrospectively evaluated our experience with stenting of the vertebral artery in an effort to determine the risk of distal embolization associated with the procedure. Methods. Between June 2000 and May 2005, 35 patients with 38 stenting procedures for atherosclerotic disease of the vertebral origin in our institution were identified. The average age of the patients was 60.3 years (range 32-76 years). Sixteen of these patients (with 18 stents) had MR imaging of the brain with diffusion-weighted imaging and an apparent diffusion coefficient map within 2 days before and after procedure. Results. On seven of the 16 postprocedural diffusion-weightedmore » MR images, a total of 57 new hyperintensities were visible. All these lesions were focal in nature. One patient demonstrated a new diffusion-weighted imaging abnormality in the anterior circulation without MR evidence of posterior circulation ischemia. Six of 16 patients had a total of 25 new lesions in the vertebrobasilar circulation in postprocedural diffusion-weighted MR images. One patient in this group was excluded from the final analysis because the procedure was complicated by basilar rupture during tandem stent deployment in the basilar artery. Hence, new diffusion-weighted imaging abnormalities were noted in the vertebrobasilar territory in 5 of 15 patients after 17 stenting procedures, giving a 29% rate of diffusion-weighted imaging abnormalities per procedure. No patient with bilateral stenting had new diffusion-weighted imaging abnormalities. Conclusion. Stenting of stenoses of the vertebral artery origin may be associated with a significant risk of asymptomatic distal embolization. Angiography, placement of the guiding catheter, inflation of the stent balloon, and crossing the lesion with guidewires or balloon catheters may potentially cause distal embolization. Further studies to evaluate measures to increase the safety of vertebral artery stenting, such as the use of distal protection devices or short-term postprocedural anticoagulation, should be considered for patients with clear indications for this procedure.« less

  2. Stent placement vs. balloon angioplasty for popliteal artery treatment: two-year results of a prospective, multicenter, randomized trial.

    PubMed

    Rastan, Aljoscha; Krankenberg, Hans; Baumgartner, Iris; Blessing, Erwin; Müller-Hülsbeck, Stefan; Pilger, Ernst; Scheinert, Dierk; Lammer, Johannes; Beschorner, Ulrich; Noory, Elias; Neumann, Franz-Josef; Zeller, Thomas

    2015-02-01

    To investigate the 2-year technical and clinical results of primary nitinol stent placement in comparison with percutaneous transluminal angioplasty (PTA) in the treatment of de novo lesions of the popliteal artery. The ETAP study (Endovascular Treatment of Atherosclerotic Popliteal Artery Lesions: balloon angioplasty vs. primary stenting; www.ClinicalTrials.gov identifier NCT00712309) is a prospective, randomized trial that enrolled 246 patients (158 men; mean age 72 years) who were randomly assigned to receive a nitinol stent (n=119) or PTA (n=127) for lesions averaging 42.3 mm in length. The results of the primary study endpoint were published. Secondary outcome measures and endpoints included primary patency (freedom from duplex-detected target lesion restenosis), target lesion revascularization (TLR), secondary patency, changes in ankle-brachial index and Rutherford class, and event-free survival (freedom from target limb amputation, TLR, myocardial infarction, and death). In total, 183 patients (89 stent and 94 PTA) were available for the 2-year analysis. The primary patency rate was significantly higher in the stent group (64.2%) than in the PTA group (31.3%, p=0.0001). TLR rates were 22.4% and 59.5%, respectively (p=0.0001). When provisional stent placement in the PTA arm was not considered as TLR and loss in patency, the differences prevailed between the study groups but were not significant (64.2% vs. 56.1% for primary patency, respectively; p=0.44). A significant improvement in ABI and Rutherford category was observed at 2 years in both groups. In treatment of obstructive popliteal artery lesions, provisional stenting reveals equivalent patency in comparison to primary stenting. However, the 2-year results of this trial suggest the possibility of a shift toward higher patency rates in favor of primary stenting. © The Author(s) 2015.

  3. Comparative Analysis of Sequential Proximal Optimizing Technique Versus Kissing Balloon Inflation Technique in Provisional Bifurcation Stenting: Fractal Coronary Bifurcation Bench Test.

    PubMed

    Finet, Gérard; Derimay, François; Motreff, Pascal; Guerin, Patrice; Pilet, Paul; Ohayon, Jacques; Darremont, Olivier; Rioufol, Gilles

    2015-08-24

    This study used a fractal bifurcation bench model to compare 6 optimization sequences for coronary bifurcation provisional stenting, including 1 novel sequence without kissing balloon inflation (KBI), comprising initial proximal optimizing technique (POT) + side-branch inflation (SBI) + final POT, called "re-POT." In provisional bifurcation stenting, KBI fails to improve the rate of major adverse cardiac events. Proximal geometric deformation increases the rate of in-stent restenosis and target lesion revascularization. A bifurcation bench model was used to compare KBI alone, KBI after POT, KBI with asymmetric inflation pressure after POT, and 2 sequences without KBI: initial POT plus SBI, and initial POT plus SBI with final POT (called "re-POT"). For each protocol, 5 stents were tested using 2 different drug-eluting stent designs: that is, a total of 60 tests. Compared with the classic KBI-only sequence and those associating POT with modified KBI, the re-POT sequence gave significantly (p < 0.05) better geometric results: it reduced SB ostium stent-strut obstruction from 23.2 ± 6.0% to 5.6 ± 8.3%, provided perfect proximal stent apposition with almost perfect circularity (ellipticity index reduced from 1.23 ± 0.02 to 1.04 ± 0.01), reduced proximal area overstretch from 24.2 ± 7.6% to 8.0 ± 0.4%, and reduced global strut malapposition from 40 ± 6.2% to 2.6 ± 1.4%. In comparison with 5 other techniques, the re-POT sequence significantly optimized the final result of provisional coronary bifurcation stenting, maintaining circular geometry while significantly reducing SB ostium strut obstruction and global strut malapposition. These experimental findings confirm that provisional stenting may be optimized more effectively without KBI using re-POT. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Results of celiac trunk stenting during fenestrated or branched aortic endografting.

    PubMed

    Wattez, Hélène; Martin-Gonzalez, Teresa; Lopez, Benjamin; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Sobocinski, Jonathan; Haulon, Stéphan

    2016-12-01

    Endovascular repair of aortic aneurysms involving the visceral segment of the aorta often requires placement of a covered bridging stent in the celiac axis (CA). The median arcuate ligament (MAL) is a fibrous arch that unites the diaphragmatic crura on either side of the aortic hiatus. The ligament may compress and distort the celiac artery and result in difficult cannulation, or stenosis and occlusion of the vessel. This study evaluated the influence of the MAL compression on the technical success and the patency of the celiac artery after branched and fenestrated endovascular aortic repair. We retrospectively analyzed a cohort of consecutive patients treated electively for complex aneurysms with branched and fenestrated endovascular aortic repair between January 2007 and April 2014. All data were collected prospectively. Analysis of preoperative computed tomography angiography on a three-dimensional workstation determined the presence of MAL compression. Patency of the CA bridging stent was assessed during follow-up by computed tomography angiography and duplex ultrasound evaluation. Statistical analysis was performed to compare the outcomes of patients with MAL (MAL+) and without MAL (MAL-) compression. Of 315 patients treated for aortic disease involving the visceral segment during the study period, 113 had endografts designed with a branch (n = 57) or fenestration (n = 56) for the CA. In 45 patients (39.8%), asymptomatic compression of the CA by the MAL was depicted (MAL+). Complex endovascular techniques were required in this group to access the CA in 16 (14.2%) patients (vs none in the MAL- group; P = .003), which lead to a failed bridging stent implantation in seven patients (6.2%). Increased operative time and dose area product were observed in the MAL+ group, but this did not reach statistical significance. In the MAL+ group, no thrombosis of the CA bridging stents were observed during follow-up; an external compression of the CA bridging stent was depicted in six patients but without hemodynamic effect on duplex ultrasound imaging. In the MAL- group, one CA bridging stent occlusion occurred owing to an embolus from a cardiac source. MAL compression is associated with good celiac trunk bridging stent patency during follow-up, but with a higher rate of technical difficulties and failed bridging stent implantation during the procedure. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Classification and outcomes of extended arch repair for acute Type A aortic dissection: a systematic review and meta-analysis.

    PubMed

    Smith, Holly N; Boodhwani, Munir; Ouzounian, Maral; Saczkowski, Richard; Gregory, Alexander J; Herget, Eric J; Appoo, Jehangir J

    2017-03-01

    Distal extent of repair in patients undergoing surgery for acute Type A aortic dissection (ATAAD) is controversial. Emerging hybrid techniques involving open and endovascular surgery have been reported in small numbers by select individual centres. A systematic review and meta-analysis was performed to investigate the outcomes following extended arch repair for ATAAD. A classification system is proposed of the different techniques to facilitate discussion and further investigation. Using Ovid MEDLINE, 38 studies were identified reporting outcomes for 2140 patients. Studies were categorized into four groups on the basis of extent of surgical aortic resection and the method of descending thoracic aortic stent graft deployment; during circulatory arrest (frozen stented elephant trunk) or with normothermic perfusion and use of fluoroscopy (warm stent graft): (I) surgical total arch replacement, (II) total arch and frozen stented elephant trunk, (III) hemiarch and frozen stented elephant trunk and (IV) total arch and warm stent graft. Perioperative event rates were obtained for each of the four groups and the entire cohort using pooled summary estimates. Linearized rates of late mortality and reoperation were calculated. Overall pooled hospital mortality for extended arch techniques was 8.6% (95% CI 7.2-10.0). Pooled data categorized by surgical technique resulted in hospital mortality of 11.9% for total arch, 8.6% total arch and frozen stented elephant trunk, 6.3% hemiarch and frozen stented elephant trunk and 5.5% total arch and 'warm stent graft'. Overall incidence of stroke for the entire cohort was 5.7% (95% CI 3.6-8.2). Rate of spinal cord ischaemia was 2.0% (95% CI 1.2-3.0). Pooled linearized rate of late mortality was 1.66%/pt-yr (95% CI 1.34-2.07) with linearized rate of re-operation of 1.62%/pt-yr (95% CI 1.24-2.05). Perioperative results of extended arch procedures are encouraging. Further follow-up is required to see if long-term complications are reduced with these emerging techniques. The proposed classification system will facilitate future comparison of short- and long-term results of different techniques of extended arch repair for ATAAD. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Primary stenting for TASC C and D femoropopliteal lesions: one-year results from a multicentric trial on 203 patients.

    PubMed

    Brouillet, Julie; Deloose, Koen; Goueffic, Yann; Poirier, Mathieu; Midy, Dominique; Caradu, Caroline; Ducasse, Eric

    2018-06-01

    Recent advances in endovascular techniques have made it a seductive choice in the management of TASC C and D lesions. Currently, this tendency remains controversial, despite high success rates. The aim of the study was to regroup and harmonize the results of three surgical teams in 5 centers in order to obtain the largest series ever published on TASC C and D femoro-popliteal lesions primary stenting. Two hundred and three patients and 209 lower limbs were included from March 2008 to October 2013. Each patient underwent primary stenting for TASC C or D femoro-popliteal lesions. Mean age was 70±10; 71.4% were male with a 39.8% rate of coronary heart disease, 20.1% of renal insufficiency and 35.9% of diabetes; 57,4% suffered from claudication and 42.6% from critical limb ischemia (CLI); 61.8% of the 144 limbs analyzed for run-off presented with 3 patent infra-popliteal arteries. Four hundred and three stents were implanted in the 209 limbs included. Median stented length was 252 mm. Associated procedures were performed in 35 patients (17.0%) including 4.3% minor amputations. The 30-day mortality rate was 1.4% (3 patients). Major complications occurred in 19 patients (9.3%) including 7 patients (3.4%) presented with early in-stent thrombosis. Median follow-up duration was 12 months (range 9.5-17.2 months). The 12-month mortality rate was 11.8% (24 patients). The 3, 6 and 12 months primary patency rates according to Kaplan Meier estimates were 98.1±0.9, 85.2±2.5 and 67.0±3.3% respectively. Secondary patency rates were 96.1±1.9, 89.3±3.0 and 75.7±4.2% respectively. A subgroup analysis reported significantly higher patency rates for TASC C lesions compared to TASC D lesions (82.1% vs. 44% respectively, P=0.009). The 12-month in-stent thrombosis and restenosis rates were 19.6% and 13.9% respectively. A subgroup analysis showed higher rates of in-stent restenosis for TASC D lesions compared to TASC C lesions (35% vs. 10% respectively, P=0.005). The stent fracture rate was equal to 10.2% (30 stents). Occurrence of in-stent thrombosis and restenosis were associated with 3 and 5 cases of stent fracture (type II to IV) respectively. Freedom from TLR was 70.5%. Rutherford class decreased from 3.7 to 0.9 (3.52±1.06 to 0.75±1.24) (P<0.0001). At 12 months 61.3% were asymptomatic, 33.3% suffered from claudication (21.3% Rutherford 1) and 5.4% suffered from CLI. Healing rates were 63.9% with a limb salvage rate of 95.5% and a major amputation rate of 3.8%. This is the largest series of TASC C and D femoro-popliteal lesions primary stenting to our knowledge. The results are encouraging with acceptable primary patency and clinical improvement at 12 months. Results from mid- to long-term follow-up are awaited.

  7. Comparative Computed Flow Dynamic Analysis of Different Optimization Techniques in Left Main Either Provisional or Culotte Stenting.

    PubMed

    Rigatelli, Gianluca; Dell'Avvocata, Fabio; Zuin, Marco; Giatti, Sara; Duong, Khanh; Pham, Trung; Tuan, Nguyen Si; Vassiliev, Dobrin; Daggubati, Ramesh; Nguyen, Thach

    2017-12-01

    Provisional and culotte are the most commonly used techniques in left main (LM) stenting. The impact of different post-dilation techniques on fluid dynamic of LM bifurcation has not been yet investigated. The aim of this study is to evaluate, by means of computational fluid dynamic analysis (CFD), the impact of different post-dilation techniques including proximal optimization technique (POT), kissing balloon (KB), POT-Side-POT and POT-KB-POT, 2-steps Kissing (2SK) and Snuggle Kissing balloon (SKB) on flow dynamic profile after LM provisional or culotte stenting. We considered an LM-LCA-LCX bifurcation reconstructed after reviewing 100 consecutive patients (mean age 71.4 ± 9.3 years, 49 males) with LM distal disease. The diameters of LAD and LCX were modelled according to the Finnet's law as following: LM 4.5 mm, LAD 3.5 mm, LCX 2.75 mm, with bifurcation angle set up at 55°. Xience third-generation stent (Abbot Inc., USA) was reconstructed and virtually implanted in provisional/cross-over and culotte fashion. POT, KB, POT-side-POT, POT-KB-POT, 2SK and SKB were virtually applied and analyzed in terms of the wall shear stress (WSS). Analyzing the provisional stenting, the 2SK and KB techniques had a statistically significant lower impact on the WSS at the carina, while POT seemed to obtain a neutral effect. In the wall opposite to the carina, the more physiological profile has been obtained by KB and POT with higher WSS value and smaller surface area of the lower WSS. In culotte stenting, at the carina, POT-KB-POT and 2SK had a very physiological profile; while at the wall opposite to the carina, 2SK and POT-KB-POT decreased significantly the surface area of the lower WSS compared to the other techniques. From the fluid dynamic point of view in LM provisional stenting, POT, 2SK and KB showed a similar beneficial impact on the bifurcation rheology, while in LM culotte stenting, POT-KB-POT and 2SK performed slightly better than the other techniques, probably reflecting a better strut apposition.

  8. The insertion of self expanding metal stents with flexible bronchoscopy under sedation for malignant tracheobronchial stenosis: a single-center retrospective analysis.

    PubMed

    McGrath, Emmet E; Warriner, David; Anderson, Paul

    2012-02-01

    To describe a 10-year experience of inserting Ultraflex™ self-expanding metal stents (SEMS) under sedation using flexible bronchoscopy for the treatment of malignant tracheobronchial stenosis in a tertiary referral centre. Medical notes were retrospectively reviewed for all patients who underwent SEMS insertion between 1999 and 2009. A data analysis of 68 patients who had Ultraflex™ SEMS inserted under sedation was completed. Thirty three males and 35 females with a mean age of 67.9 years (range 35-94) presented with features including dyspnea/respiratory distress (39 patients), stridor (16 patients) and hemoptysis/dyspnea (13 patients). Etiology of stenosis included lung cancer (46 patients) esophageal cancer (14 patients) and other malignancies (8 patients). Mean dose of midazolam administered was 5mg (range 0-10mg). The trachea was the most common site of stent insertion followed by the right and left main bronchus, respectively. Adjuvant laser therapy was applied at some stage in 31% of all cases, and chemotherapy and/or radiotherapy was administered to at least 64% of patients with malignant disease. Hemoptysis and stent migration were the most frequent complications (5 and 4 patients, respectively). The mean survival time of stented non-small cell lung cancer (NSCLC) patients was 214 days (range 5-1233) and that of esophageal malignancy was 70 days (range 12-249). Mean pack-year history of individuals with lung cancer requiring stent insertion was 37 (range 2-100). Ultraflex stents offer a safe and effective therapy for patients who are inoperable or unresectable that otherwise would have no alternative therapy. It has an immediate beneficial effect upon patients, not only through symptom relief but, in some, through prolongation of life. Survival data is no worse than other studies using different varieties of stents and insertion techniques indicating its longer-term efficacy. Moreover, this report highlights the feasibility of performing this procedure successfully in a respiratory unit, without the need for general anesthesia. Copyright © 2011 SEPAR. Published by Elsevier Espana. All rights reserved.

  9. Does stent strut design impact clinical outcomes: comparative safety and efficacy of Endeavor Resolute versus Resolute Integrity zotarolimus-eluting stents.

    PubMed

    Di Santo, Pietro; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Harnett, David T; Singh, Kuljit; Moreland, Robert; Chong, Aun-Yeong; Dick, Alexander; Labinaz, Marino; Froeschl, Michael; Froeschl, Michael; Le May, Michael R; So, Derek Y; Hibbert, Benjamin

    2015-10-07

    Percutaneous coronary intervention is the most commonly performed method of revascularizing obstructive coronary artery disease. The impact of stent strut design on clinical outcomes remains unclear. The Endeavour Resolute (ER-ZES) and the Resolute Integrity (RI-ZES) zotarolimus-eluting stents utilize identical polymers and anti-proliferative agents, differing only in their respective strut design. This study assessed the comparative safety and efficacy of these two stents in unrestricted contemporary real-world practice. A total of 542 patients were identified, corresponding to 340 ER-ZES and 480 RI-ZES. The primary endpoint was major adverse cardiac events (MACE) defined by a composite of death, nonfatal myocardial infarction and stroke. Secondary endpoints included post-procedural length of stay, in-stent restenosis, target lesion revascularization, target vessel revascularization, coronary artery bypass grafting and stent thrombosis. MACE occurred in 3.2% of the ER-ZES cohort and 5.0% of the RI-ZES cohort (p= 0.43). Adjusted analysis utilizing propensity score-adjusted odds ratio for MACE, was 1.37 (95% CI 0.46-4.07, p=0.57). The mortality rate (0.9% ER-ZES vs. 1.9% RI-ZES, p=0.59), non-fatal MI (2.3% ER-ZES vs. 3.1% RI-ZES, p=0.75) and stroke (0.0% ER-ZES vs. 0.3% RI-ZES, p=0.85) were not different. Additionally, there was no difference in any of secondary outcomes. The clinical performance and safety of both ER-ZES and RI-ZES were not statistically different, despite differences in stent strut design.

  10. Pancreatic stents for the prevention of post-endoscopic retrograde cholangiopancreatography pancreatitis should be inserted up to the pancreatic body or tail.

    PubMed

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Sato, Yuki; Irie, Hiroki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Hikichi, Takuto; Ohira, Hiromasa

    2018-06-14

    To investigate the location to which a pancreatic stent should be inserted to prevent post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP). Over a ten-year period at our hospital, 296 patients underwent their first ERCP procedure and had a pancreatic stent inserted; this study included 147 patients who had ERCP performed primarily for biliary investigation and had a pancreatic stent inserted to prevent PEP. We divided these patients into two groups: 131 patients with a stent inserted into the pancreatic head (head group) and 16 patients with a stent inserted up to the pancreatic body or tail (body/tail group). Patient characteristics and ERCP factors were compared between the groups. Pancreatic amylase isoenzyme (p-AMY) levels in the head group were significantly higher than those in the body/tail group [138.5 (7.0-2086) vs 78.5 (5.0-1266.5), P = 0.03] [median (range)]. No cases of PEP were detected in the body/tail group [head group, 12 (9.2%)]. Of the risk factors for post-ERCP hyperamylasemia (≥ p-AMY median, 131 IU/L), procedure time ≥ 60 min [odds ratio (OR) 2.65, 95%CI: 1.17-6.02, P = 0.02) and stent insertion into the pancreatic head (OR 3.80, 95%CI: 1.12-12.9, P = 0.03) were identified as independent risk factors by multivariate analysis. Stent insertion up to the pancreatic body or tail reduces the risk of post-ERCP hyperamylasemia and may reduce the risk of PEP.

  11. Determining clinical benefits of drug-eluting coronary stents according to the population risk profile: a meta-regression from 31 randomized trials.

    PubMed

    Moreno, Raul; Martin-Reyes, Roberto; Jimenez-Valero, Santiago; Sanchez-Recalde, Angel; Galeote, Guillermo; Calvo, Luis; Plaza, Ignacio; Lopez-Sendon, Jose-Luis

    2011-04-01

    The use of drug-eluting stents (DES) in unfavourable patients has been associated with higher rates of clinical complications and stent thrombosis, and because of that concerns about the use of DES in high-risk settings have been raised. This study sought to demonstrate that the clinical benefit of DES increases as the risk profile of the patients increases. A meta-regression analysis from 31 randomized trials that compared DES and bare-metal stents, including overall 12,035 patients, was performed. The relationship between the clinical benefit of using DES (number of patients to treat [NNT] to prevent one episode of target lesion revascularization [TLR]), and the risk profile of the population (rate of TLR in patients allocated to bare-metal stents) in each trial was evaluated. The clinical benefit of DES increased as the risk profile of each study population increased: NNT for TLR=31.1-1.2 (TLR for bare-metal stents); p<0.001. The use of DES was safe regardless of the risk profile of each study population, since the effect of DES in mortality, myocardial infarction, and stent thrombosis, was not adversely affected by the risk profile of each study population (95% confidence interval for β value 0.09 to 0.11, -0.12 to 0.19, and -0.03 to-0.15 for mortality, myocardial infarction, and stent thrombosis, respectively). The clinical benefit of DES increases as the risk profile of the patients increases, without affecting safety. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  12. Drug-eluting versus bare-metal coronary stents: where are we now?

    PubMed

    Amoroso, Nicholas S; Bangalore, Sripal

    2012-11-01

    Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).

  13. A comparative study of short- and medium-term outcomes comparing emergent surgery and stenting as a bridge to surgery in patients with acute malignant colonic obstruction.

    PubMed

    Kavanagh, Dara O; Nolan, Blathnaid; Judge, Ciaran; Hyland, John M P; Mulcahy, Hugh E; O'Connell, P Ronan; Winter, Des C; Doherty, Glen A

    2013-04-01

    The use of self-expanding metal stents as a bridge to surgery in the setting of malignant colorectal obstruction has been advocated as an acceptable alternative to emergency surgery. However, concerns about the safety of stenting have been raised following recent randomized studies. The aim of the current study was to compare outcomes. This was an observational, comparative study. This study was conducted at a tertiary referral center and university teaching hospital. Patients with malignant colonic obstruction (n = 49) treated by either emergency surgery (n = 26) or with stent placement (n = 23) as a bridge to surgery were identified and followed. Short-term outcomes including stoma rates and postoperative morbidity and medium-term oncological outcomes were compared based on an "intention-to-treat" analysis. Patients in both groups were well matched on clinicopathological parameters. Technical and clinical successful stent deployment was achieved in 91% and 83%. This did not adversely impact cancer-specific and overall survival (log rank = nonsignificant). No difference was observed in stoma rates, primary anastomosis rates, perioperative mortality rates, or reoperation rates between the 2 groups. Significantly fewer patients underwent total colectomy in the stent group in comparison with the emergency surgery group (1/23 vs 6/26: p = 0.027). There was no difference in postoperative morbidity (59% vs 66%: p = 0.09). There was a significant reduction in readmission rates in the stent group (5/26 vs 0/23: p = 0.038). The small sample size of this study could lead to type II error. In addition, the study was nonrandomized and demonstrated a limited length of follow-up. Despite a high rate of technical and clinical success in selected patients with colonic obstruction, stenting has no impact on stoma rates. Despite concerns about the rate of stent-associated perforation, stenting does not adversely impact disease progression or survival. Future comparative trials are essential to better define the role of stenting in this setting and to ensure that we are not using costly technology to create an elective operative situation without concomitant patient benefits.

  14. Factors Associated with Increased Rates of Post-procedural Stroke or Death following Carotid Artery Stent Placement: A Systematic Review.

    PubMed Central

    Khan, Muhib; Qureshi, Adnan I

    2014-01-01

    Background and Purpose We provide an assessment of clinical, angiographic, and procedure related risk factors associated with stroke and/or death in patients undergoing carotid artery stent placement which will assist in patient stratification and identification of high-stent risk patients. Methods A comprehensive search of Medline from January 1st 1996 to December 31st 2011 was performed with key words “carotid artery stenosis”, “ carotid artery stenting”, “carotid artery stent placement”, “death” , ” mortality”, “stroke”, “outcome”, “clinical predictors”, “angiographic predictors”, was performed in various combinations. We independently abstracted data and assessed the quality of the studies. This analysis led to the selection of 71 articles for review. Results Clinical factors including age≥80 years, symptomatic status, procedure within 2 weeks of symptoms, chronic renal failure, diabetes mellitus, and hemispheric TIA were associated with stroke (ischemic or hemorrhagic) and death within 1 month after carotid artery stent placement. Angiographic factors including left carotid artery intervention, stenosis > 90%, ulcerated and calcified plaques, lesion length > 10mm, thrombus at the site, ostial involvement, predilation without EPD, ICA-CCA angulation > 60%, aortic arch type III, and aortic arch calcification were also associated with 1 month stroke and/or death. Intra-procedural platelet GP IIb/IIIa inhibitors, protamine use, multiple stents, predilatation prior to stent placement were associated with stroke (ischemic or hemorrhagic) and death after carotid artery stent placement. Intraprocedural use of embolic protection devices and stent design (open versus closed cell design) did not demonstrate a consistent relationship with 1 month stroke and/or death. Procedural statin use, and operator and center experience of more than 50 procedures per year were protective for 1 month stroke and/or death. Conclusions Our review identified risk factors for stroke, death, and MI within 1 month in patients undergoing carotid artery stent placement. Such information will result in better patient selection for carotid artery stent placement particularly in those who are also candidates for carotid endarterectomy. PMID:24920983

  15. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    PubMed Central

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. Conclusion Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment. PMID:24958153

  16. Development of prognostic model for predicting survival after retrograde placement of ureteral stent in advanced gastrointestinal cancer patients and its evaluation by decision curve analysis.

    PubMed

    Kawano, Shingo; Komai, Yoshinobu; Ishioka, Junichiro; Sakai, Yasuyuki; Fuse, Nozomu; Ito, Masaaki; Kihara, Kazunori; Saito, Norio

    2016-10-01

    The aim of this study was to determine risk factors for survival after retrograde placement of ureteral stents and develop a prognostic model for advanced gastrointestinal tract (GIT: esophagus, stomach, colon and rectum) cancer patients. We examined the clinical records of 122 patients who underwent retrograde placement of a ureteral stent against malignant extrinsic ureteral obstruction. A prediction model for survival after stenting was developed. We compared its clinical usefulness with our previous model based on the results from nephrostomy cases by decision curve analysis. Median follow-up period was 201 days (8-1490) and 97 deaths occurred. The 1-year survival rate in this cohort was 29%. Based on multivariate analysis, primary site of colon origin, absence of retroperitoneal lymph node metastasis and serum albumin >3g/dL were significantly associated with a prolonged survival time. To develop a prognostic model, we divided the patients into 3 risk groups of favorable: 0-1 factors (N.=53), intermediate: 2 risk factors (N.=54), and poor: 3 risk factors (N.=15). There were significant differences in the survival profiles of these 3 risk groups (P<0.0001). Decision curve analyses revealed that the current model has a superior net benefit than our previous model for most of the examined probabilities. We have developed a novel prognostic model for GIT cancer patients who were treated with retrograde placement of a ureteral stent. The current model should help urologists and medical oncologists to predict survival in cases of malignant extrinsic ureteral obstruction.

  17. A New Fully Covered Self-Expandable Metal Stent for the Treatment of Postsurgical Benign Biliary Strictures.

    PubMed

    Wu, Jun; Zhou, Dong-Xun; Wang, Tian-Tian; Gao, Dao-Jian; Hu, Bing

    2017-09-01

    Endotherapy with plastic stent (PS) placement is the main modality for treating benign biliary strictures (BBSs). Fully covered self-expandable metal stents (FCSEMSs) are being increasingly used for BBS management, with high stricture resolution. However, traditional metal tents are associated with high migration, causing treatment failure. We investigated the efficacy and safety of a new FCSEMS for postsurgical BBS treatment and compared these parameters between the FCSEMS and PS treatment through retrospective analysis. The primary outcome measurements included stricture resolution, stricture recurrence, and complications. In total, 69 patients were included, of whom 32 underwent FCSEMS treatment and 37 underwent PS treatment. The technical success rate and the number of endoscopic retrograde cholangiopancreatography procedures were similar between the groups. The median stenting duration was 5.2 months (range 1.5-15.3) in the FCSEMS group and 10.7 months (range 2.5-22.6) in the PS group (P < 0.01). The stents removal rate was 96.9% in the FCSEMS group and 94.6% in the PS group. The stricture resolution rate based on intention-to-treat analysis was 83.8% in the PS group and 84.4% (27/32) in the FCSEMS group (P = 0.947), whereas the rates from per-protocol analysis were 88.6% (31/35) and 87.1% (27/31), respectively (P = 0.574). Early and late complications were similar between the groups. The median follow-up time was 43 months (range 13-71). The stricture recurrence rate was 11.1% (3/27) in the FCSEMS group and 16.1% (5/31) in the PS group (P = 0.435). The new FCSEMS and the PS approach showed similar efficacy and safety in postsurgical BBS treatment. However, the FCSEMS required fewer procedural steps and shorter stenting time, making it an effective alternative modality.

  18. Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms.

    PubMed

    Kono, K; Terada, T

    2013-10-01

    SACE is performed for complex aneurysms. There are several configurations of stent placement for bifurcation aneurysms. We investigated hemodynamics among 8 different configurations of stent placement, which may relate to the recanalization rate. We created a silicone block model of a patient-specific asymmetric bifurcation aneurysm. Enterprise closed-cell stents were deployed in the model as various configurations. 3D images of these stents were obtained by micro-CT. We performed CFD simulations for a no-stent model and 8 stent models: a single stent from a proximal vessel to a right or left distal vessel, a horizontal stent, a kissing-Y stent with a uniformly narrowed structure, a nonoverlapping-Y stent, a virtual-Y stent with no narrowed structure (fusion of 2 single stents), and 2 different crossing-Y stents with a focally narrowed structure. Hemodynamic parameters were evaluated. Cycle-averaged velocity and WSS in the aneurysm were reduced because of stent placement in the following order: single stent (19% reduction in cycle-averaged velocity) < nonoverlapping-Y stent (29%) < virtual-Y stent (32%) < horizontal stent (39%) < kissing-Y stent (48%) < crossing-Y stent (54%). Kissing- and crossing-Y stents redirected impingement flow into the distal vessels because of lowered porosity of stents due to narrowed structures. Among 8 different configurations of stent placement, kissing- and crossing-Y stents showed the strongest reduction in flow velocity in the aneurysm because of lowered porosity of stents and redirection of impingement flow. This may be a desirable reconstruction of flow hemodynamics and may decrease recanalization rates in SACE.

  19. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    PubMed

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Intravascular Ultrasound and Angiographic Predictors of In-Stent Restenosis of Chronic Total Occlusion Lesions.

    PubMed

    Kang, Jeehoon; Cho, Young-Seok; Kim, Seong-Wook; Park, Jin Joo; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju

    2015-01-01

    Despite the benefits of successful percutaneous coronary interventions (PCIs) for chronic total occlusion (CTO) lesions, PCIs of CTO lesions still carry a high rate of adverse events, including in-stent restenosis (ISR). Because previous reports have not specifically investigated the intravascular ultrasound (IVUS) predictors of ISR in CTO lesions, we focused on these predictors. We included 126 patients who underwent successful PCIs, using drug-eluting stents, and post-PCI IVUS of CTO lesions. Patient and lesion characteristics were analyzed to elucidate the ISR predictors. In each lesion, an average of 1.7 ± 0.7 (mean length, 46.4 ± 20.3 mm) stents were used. At 9 months follow-up, 14 (11%) patients demonstrated ISR, and 8 (6.3%) underwent target lesion revascularization. Multivariate logistic regression analysis showed that the independent predictors of ISR were the post-PCI minimal luminal diameter (MLD) and the stent expansion ratio (SER; minimal stent cross-sectional area (CSA) over the nominal CSA of the implanted stent), measured using quantitative coronary angiography (QCA) and IVUS, respectively. A receiver operating characteristic analysis indicated that the best post-PCI MLD and SER cut-off values for predicting ISR were 2.4 mm (area under the curve [AUC], 0.762; 95% confidence interval (CI), 0.639-0.885) and 70% (AUC, 0.714; 95% CI, 0.577-0.852), respectively. Lesions with post-PCI MLD and SER values less than these threshold values were at a higher risk of ISR, with an odds ratio of 23.3 (95% CI, 2.74-198.08), compared with lesions having larger MLD and SER values. Thus, the potential predictors of ISR, after PCI of CTO lesions, are the post-PCI MLD and SER values. The ISR rate was highest in lesions with a post-PCI MLD ≤2.4 mm and an SER ≤70%.

  1. A novel high nitrogen nickel-free coronary stents system: evaluation in a porcine model.

    PubMed

    Zhang, Bin; Chen, Ming; Zheng, Bo; Wang, Xin Gang; Wang, Xi Ting; Fan, Yuan Yuan; Huo, Yong

    2014-04-01

    To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Three types of stents were randomly implanted in different coronary arteries of the same pig: 316 L stainless steel BMS (316 L-BMS) (n=12), novel high nitrogen nickel-free stents Grid A (NF-A-BMS) (n=12) and novel high nitrogen nickel-free stents Grid B (NF-B-BMS) (n=12). In total, eighteen animals underwent successful random placement of 36 oversized stents in the coronary arteries. Coronary angiography was performed after 36 d of stents implantation. Nine animals were respectively sacrificed after 14 d and 36 d for histomorphologic analysis. Quantitative coronary angiography (QCA) showed similar luminal loss (LL) in the three groups: (0.21 ± 0.17) mm for 316 L-BMS, (0.16 ± 0.12) mm for NF-A-BMS, (0.24 ± 0.15) mm for NF-B-BMS (P>0.05). Histomorphomeric analysis after 15 d and 36 d revealed that there was also no significant difference among the three groups in neointimal area (NA) with similar injury scores respectively. High magnification histomorphologic examination showed similar inflammation scores in the three groups, but NF-A-BMS group had poorer endothelialization scores compared with NF-B-BMS group, 2.00 ± 0.63 vs. 2.83 ± 0.41 (P=0.015) at 15 d, which also could be proved by the scanning electron microscope. However, the difference could not been observed at 36 d. The novel NF-BMS showed similar safety as 316 L-BMS during the short-term study. NF-B-BMS had better endothelialization than NF-A-BMS and this may owe to the specific strut units. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  2. Analysis of emboli during carotid stenting with distal protection device.

    PubMed

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p < 0.001). During stenting and angioplasty with the protection device, 7,395 emboli with 42% solids were detected (p < 0.001). Finally injection of contrast after the procedure, with the protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  3. Validation of the Spanish version of Ureteral Stent Symptom Questionnaire: prevalence of symptoms in a tertiary care center in Mexico.

    PubMed

    Olvera-Posada, Daniel; Suárez-Santos, Myrna; Castillejos-Molina, Ricardo; Gabilondo-Navarro, Fernando; Méndez-Probst, Carlos Enrique

    2014-03-01

    To develop and to validate the Spanish version of the Ureteral Stent Symptom Questionnaire (USSQ). Describe the prevalence of symptoms associated with the presence of ureteral stent in a Spanish-speaking population. We developed and delivered the Spanish USSQ version to patients who underwent ureteral stent placement after endourological procedures. We determined the internal consistency and the instrument's sensitivity to change. Results of the patients were compared with a control group of healthy individuals. We analyzed the prevalence of symptoms in the six domains of the questionnaire and the overall quality of life. We compared the means of the results by gender to find significant differences in associated symptoms. We obtained good internal consistency values of the instrument. Significant differences were obtained after sensitivity to change analysis in the scores of all domains except sexual performance. The correlation between the domains of urinary symptoms, pain, and general health was high. The analysis of specific symptoms showed important affection in all domains, being more significant in urinary symptoms and pain. The ureteral catheter also affected the daily life and work performance. There were no significant differences when comparing the symptoms by gender or age. Spanish version of the USSQ is appropriate for assessing the symptoms associated with ureteral stent in the Spanish-speaking population. The ureteral catheter significantly affects the various aspects of life in this population.

  4. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    PubMed

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.

  5. A prospective group sequential study evaluating a new type of fully covered self-expandable metal stent for the treatment of benign biliary strictures (with video).

    PubMed

    Poley, Jan-Werner; Cahen, Djuna L; Metselaar, Herold J; van Buuren, Henk R; Kazemier, Geert; van Eijck, Casper H J; Haringsma, Jelle; Kuipers, Ernst J; Bruno, Marco J

    2012-04-01

    Fully-covered self expandable metal stents (fcSEMSs) are an alternative to progressive plastic stenting for the treatment of benign biliary strictures (BBS) with the prospect of a higher treatment efficacy and the need for fewer ERCPs, thereby reducing the burden for patients and possibly costs. Key to this novel treatment is safe stent removal. To investigate the feasibility and safety of stent removal of a fcSEMS with a proximal retrieval lasso: a long wire thread integrated in the proximal ends of the wire mesh that hangs freely in the stent lumen. Pulling it enables gradual removal of the stent inside-out. A secondary aim was success of stricture resolution. Non-randomized, prospective follow-up study with 3 sequential cohorts of 8 patients with BBS. Academic tertiary referral center. Eligible patients had strictures either postsurgical (post-cholecystectomy (LCx) or liver transplantation (OLT)), due to chronic pancreatitis (CP), or papillary stenosis (PF). Strictures had to be located at least 2 cm below the liver hilum. All patients had one plastic stent in situ across the stricture and had not undergone previous treatment with either multiple plastic stents or fcSEMS. The first cohort of patients underwent stent placement for 2 months, followed by 3 months if the stricture had not resolved. The second and third cohort started with 3 months and 4 months, respectively, both followed by another 4 months if indicated. Treatment success was defined by stricture resolution at cholangiography, the ability to pass an inflated extraction balloon and clinical follow-up (at least 6 months). safety of stent removal. Secondary outcomes were complications and successful stricture resolution. A total of 23 patients (11 female; 20-67 yrs) were eligible for final analysis. One patient developed a malignant neuroendocrine tumor in the setting of CP. Strictures were caused by CP (13), OLT (6), LCx (3) and PF (1). In total 39 fcSEMS were placed and removed. Removals were easy and without complications. Transient pain after insertion was common (13 of 23/56%) but was easily managed by analgesics in all patients. Other complications were cholecystitis (1), cholangitis due to stent migration (1, stent replaced) or stent clogging (2, managed endoscopically) and worsening of CP (2). In these patients, the fcSEMS was removed and replaced after pancreatic sphincterotomy and PD stent placement. Median follow-up was 15 months (range 11-25). Overall treatment success was 61% (14/23); in the CP group 46%, in the remaining patients 80% (p = 0.11). Patients with stricture resolution after removal of the first stent (n = 7; success 6/7) showed a trent towards a more sustained treatment success than patients who needed a 2nd stent placement (n = 16; success 8/16); p = 0.12). Small number of patients with regard to secondary outcomes. Removal of a new type of fcSEMS with a proximal retrieval lasso in patients with BBS proved easy and uncomplicated. Treatment success for CP strictures was higher compared to what is known from results of progressive plastic stenting protocols. For other indications treatment success was comparable to progressive plastic stenting, but with the prospect of fewer ERCP procedures. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  6. Analysis of Transportation Options for Commercial Spent Fuel in the U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalinina, Elena; Busch, Ingrid Karin

    The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S.more » Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage The U.S. Department of Energy (DOE) is laying the groundwork for implementing interim storage and associated transportation of spent nuclear fuel (SNF) highand associated transportation of spent nuclear fuel (SNF) and high and associated transportation of spent nuclear fuel (SNF) highand associated transportation of spent nuclear fuel (SNF) and high and associated transportation of spent nuclear fuel (SNF) highand associated transportation of spent nuclear fuel (SNF) and highand associated transportation of spent nuclear fuel (SNF) and high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) highand associated transportation of spent nuclear fuel (SNF) and high and associated transportation of spent nuclear fuel (SNF) high and associated transportation of spent nuclear fuel (SNF) highand associated transportation of spent nuclear fuel (SNF)...« less

  7. Comparative geometric analysis of renal artery anatomy before and after fenestrated or snorkel/chimney endovascular aneurysm repair.

    PubMed

    Ullery, Brant W; Suh, Ga-Young; Lee, Jason T; Liu, Brian; Stineman, Robert; Dalman, Ronald L; Cheng, Christopher P

    2016-04-01

    The durability of stent grafts may be related to how procedures and devices alter native anatomy. We aimed to quantify and compare renal artery geometry before and after fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). Forty patients (75 ± 6 years) underwent computed tomographic angiography before and after F-EVAR (n = 21) or Sn-EVAR (n = 19), with a total of 72 renal artery stents. Renal artery geometry was quantified using three-dimensional model-based centerline extraction. The stented length was computed from the vessel origin to the stent end. The branch angle was computed relative to the orthogonal configuration with respect to the aorta. The end-stent angle was computed relative to the distal native renal artery. Peak curvature was defined as the inverse of the radius of the circumscribed circle at the highest curvature within the proximal portion from the origin to the stent end and the distal portion from the stent end to the first renal artery bifurcation. Sn-renals had greater stented length compared to F-renals (P < .05). From the pre- to the postoperative period, the origins of the Sn-left renal artery and right renal artery (RRA) angled increasingly downward by 21 ± 19° and 13 ± 17°, respectively (P < .005). The F-left renal artery and RRA angled upward by 25 ± 15° and 14 ± 15°, respectively (P < .005). From the pre- to the postoperative period, the end-stent angle of the Sn-RRA increased by 17 ± 12° (P < .00001), with greater magnitude change compared to the F-RRA (P < .0005). Peak curvature increased in distal Sn-RRAs by .02 ± .03 mm(-1) (P < .05). Acute renal failure occurred in 12.5% of patients, although none required dialysis following either F- and Sn-EVAR. Renal stent patency was 97.2% at mean follow-up of 13.7 months. Three type IA endoleaks were identified, prompting one secondary procedure, with the remainder resolving at 6-month follow-up. One renal artery reintervention was performed due to a compressed left renal stent in an asymptomatic patient. Stented renal arteries were angled more inferiorly after Sn-EVAR and more superiorly after F-EVAR due to stent configuration. Sn-EVAR induced significantly greater angle change at the stent end and curvature change distal to the stent compared to F-EVAR, although no difference in patency was noted in this small series with relatively short follow-up. Sn-RRAs exhibited greater end-stent angle change from the pre- to the postoperative period as compared to the F-RRA. These differences may exert differential effects on long-term renal artery patency, integrity, and renal function following complex EVAR for juxta- or pararenal abdominal aortic aneurysms. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. Prospective Multicenter Study on the Challenges Inherent to Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.

    PubMed

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng

    2018-06-22

    Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

  9. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    PubMed

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  10. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    PubMed

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  11. Edge Stenosis After Covered Stenting for Long Superficial Femoral Artery Occlusive Disease: Risk Factor Analysis and Prevention With Drug-Coated Balloon Angioplasty.

    PubMed

    Lin, Ting-Chao; Huang, Chun-Yang; Chen, Po-Lin; Lee, Chiu-Yang; Shih, Chun-Che; Chen, I-Ming

    2018-06-01

    To report a retrospective analysis of risk factors for edge restenosis after Viabahn stent-graft treatment of superficial femoral artery (SFA) occlusive disease and determine any protective effect of drug-coated balloons (DCBs) used at the time of stent-graft implantation. Between October 2011 and July 2016, 110 patients (mean age 73.3±7.6 years; 78 men) were treated with the Viabahn stent-graft for long SFA occlusions. Thirty-eight (34.5%) patients had DCB reinforcement at the distal edge of the stent-graft. For analysis, the population was divided into groups of no edge stenosis patients (n=88; mean lesion length 22.4±4.2 cm) and edge stenosis patients (n=22; mean lesion length 23.5±5.7 cm). The clinical outcomes, ankle-brachial indices, computed tomography angiography findings, and patency were compared at a minimum of 12 months. Logistic regression analysis was employed to determine risk factors for edge stenosis; the results are presented as the odds ratio (OR) and 95% confidence interval. No differences in clinical or procedural characteristics were identified except the higher incidence of diabetes (p=0.008) and greater need for retrograde access (p=0.033) in the edge stenosis group. DCB reinforcement reduced the incidence of edge stenosis (p=0.021) and target lesion revascularization (TLR; p=0.010) and resulted in a significantly higher 1-year primary patency rate (92.1% vs 76.4%, p=0.042). However, multivariate analysis revealed only poor distal runoff (OR 0.31, 95% CI 0.11 to 0.83, p=0.020) as a predictor of edge stenosis. The risk of edge stenosis after Viabahn implantation was higher in patients with poor distal runoff. DCB reinforcement over the distal edge reduced edge stenosis, decreased 1-year TLR, and improved 1-year primary patency.

  12. Evaluation of a fully covered self-expanding metal stent with flared ends in malignant biliary obstruction: a multicenter study.

    PubMed

    Kahaleh, Michel; Talreja, Jayant P; Loren, David E; Kowalski, Thomas E; Poneros, John M; Degaetani, Marisa; Raijman, Isaac; Sejpal, Divyesh V; Patel, Sandeep; Rosenkranz, Lauren; McNamara, Kevin N; Brijbassie, Alan; Wang, Andrew Y; Gaidhane, Monica; Sethi, Amrita; Stevens, Peter D

    2013-01-01

    Limited data are available regarding fully covered metal stents in the management of malignant distal biliary strictures. The aim of this study was to evaluate the safety of a fully covered self-expanding metal stent (FCSEMS) with flared ends, in treating malignant biliary strictures. We report our long-term retrospective analysis from 6 centers. A total of 260 patients (142 males, median age 68 y) underwent endoscopic retrograde cholangiopancreatography with placement of FCSEMS (WallFlex; Boston Scientific, Natick, MA) for the palliation of obstructive jaundice in the setting of pancreatic adenocarcinoma (169), metastatic disease (36), cholangiocarcinoma (23), ampullary cancer (19), or other (13). Patients were evaluated clinically in follow-up and biochemical tests of liver function were obtained. Data were recorded for the following variables: patient survival, duration of stent patency, the need for subsequent biliary intervention, and complications. A total of 266 FCSEMS were placed in 260 patients. There was a median survival of 100 days (range, 7 to 531 d). There was a mean follow-up of 134±118 days (range, 4 to 519 d). Biliary decompression was successful in 252 patients (97%). At the end of the study period, 121 were alive with a patent stent, 65 patients died with a patent stent, 40 patients were successfully bridged to surgery, 8 patients had their patent stent removed and had no need for further stenting, and 18 patients were lost to follow-up. Five patients who had a successfully placed FCSEMS were considered a failure due to the following reason: migration (2), cholangitis (1), stent occlusion (1), and removal for management of proximal biliary obstruction (1). Two additional patients experienced migration that did not require FCSEMS removal or replacement. Stent replacement was required in 10 patients, of whom 6 had a second FCSEMS placed. The remaining 4 were in the failure group and underwent replacement with either uncovered stents or plastic stents. Other complications, managed conservatively, included pain (2), postendoscopic retrograde cholangiopancreatography pancreatitis (4), fever (1), retroperitoneal perforation (1), and postsphincterotomy bleeding (1). The mean patency duration was 328 days (SE 19.04). The patency percentage was 83% at 3 months, 63% at 6 months, and 48.5% at 12 months. In the management of malignant distal biliary strictures, the fully covered WallFlex stent has acceptable patency and complication rates. Further long-term prospective data are required to confirm this observation.

  13. Mechanical Characteristics of Composite Knitted Stents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokuda, Takanori, E-mail: tkdtknr@gmail.com; Shomura, Yuzo; Tanigawa, Noboru

    2009-09-15

    We used metal wires and fibers to fabricate a composite knitted stent and then compare the mechanical characteristics of this stent with those of a pure metallic stent of the same construction in order to develop a stent that offers a comparable degree of expandability as metallic stents but can be used for highly curved lesions that cannot be treated using metallic stents. We fabricated two types of composite knitted stent (N-Z stents), using nitinol wire with a diameter of 0.12 mm and polypara-phenylene-benzobisoxazole (PBO) multifilament fiber (Zyron AS; Toyobo, Osaka, Japan). Stents were knitted into a cylindrical shape usingmore » the same textile pattern as a Strecker stent. Two loop lengths (L) of nitinol wire were used in the N-Z stents: L = 1.84 mm (N-Z stent L = 1.84) and L = 2.08 mm (N-Z stent L = 2.08). For the sake of comparison, we fabricated a metallic stent of nitinol using the same textile pattern (N-N stent L = 1.92). We applied a radial compression force diametrically to each stent and applied a bending force diametrically at the free end of a stent with one end fixed in order to evaluate the relationship between stent elasticity and load values. In addition, we macroscopically evaluated the generation of kinks when the stent was bent 180{sup o}. The radial compressive force when the stent diameter was reduced by 53% was 6.44 N in the case of N-Z stent L = 1.84, 6.14 N in the case of N-Z stent L = 2.08, and 4.96 N in the case of N-N stent L = 1.92 mm. The composite stent had a radial compressive force higher than that of a metallic stent. The restoring force to longitudinal direction at a 90{sup o} bending angle was 0.005 N for N-Z stent L = 1.84, 0.003 N for N-Z stent L = 2.08, and 0.034 N for N-N stent L = 1.92. The restoring force of the composite stent was significantly lower. Finally, the composite stent generated no definitive kinks at a bending angle of 180{sup o}, regardless of loop length. However, the N-N stent clearly produced kinks, causing blockage of the inner cavity. In conclusion, the use of a metal and fiber composite in the construction of a knitted stent ensures an expansion performance comparable to that of metallic stents, while providing better kink resistance.« less

  14. Clinical predictors of mortality following rotational atherectomy and stent implantation in high‐risk patients: A single center experience

    PubMed Central

    Édes, István F.; Ruzsa, Zoltán; Szabó, György; Nardai, Sándor; Becker, Dávid; Benke, Kálmán; Szilveszter, Bálint

    2015-01-01

    Objectives Our aim was to assess the procedural success and determine the clinical predictors of postprocedure mortality, following rotational atherectomy (RA) and stenting in high‐risk patients. Background RA is mainly used to facilitate stenting in complex lesions. Outcomes involving RA and stenting have been investigated, yet high‐risk patients have not been adequately described. Methods Data of 218 consecutive patients who underwent RA were evaluated in a prospective register. Primary endpoints were the angiographic success and long‐term mortality. Secondary endpoints were procedural success, consumption of the angioplasty equipment, and periprocedural major adverse cardiac events. The impact of the relevant angiographic and clinical characteristics on long‐term mortality was analyzed using uni‐ and multivariate Cox regression analysis. Results Mean age of the patients was 70 ± 8.2 years, diabetes was present in 44%, and chronic renal failure in 29%. Prior myocardial infarction and three‐vessel disease amounted to 42.2% and 32.6%, respectively. Altogether, 52.8% of patients underwent RA after a failed, non‐RA intervention attempt, and 30.7% of cases presented as acute coronary syndromes. Angiographic success was 100%, and all patients received stents after RA. Periprocedural major adverse cardiac events occurred in five (2.3%) patients. Postprocedural death was investigated, with a mean follow‐up of 36 months. Mortality amounted to 37.2%. Multivariate analysis revealed that left ventricular ejection fraction < 50%, glomerular filtration rate < 60 ml/min, cardiogenic shock, and diabetes were the only independent mortality predictors. Conclusions We have found that RA and stenting is feasible and viable in an elderly high‐risk population, with exceptional procedural success and acceptable long‐term results. © 2015 Wiley Periodicals, Inc. PMID:26032270

  15. Does the use of ureteral stents with extraction strings increase urinary infection rates?

    PubMed

    Freifeld, Yuval; Goldin, Demitry; Khalili, Luai; Friedman, Boris; Boyarsky, Leonid; Klein, Ilan; Gazy, Faris; Stein, Avi; Dekel, Yoram

    2017-05-01

    To assess the effect of ureteral stents with extraction string on the rate of postoperative UTI after ureteroscopies. Retrospective analysis of patient records who underwent ureteroscopy from January 2011 to August 2014 was performed. Patients were grouped into three groups according to postoperative stent status: non-stented or ureteral catheter for up to 24 h (NS), ureteral stent without extraction string (US) and ureteral stent with an extraction string (US-E). There were 144, 133 and 282 cases in the NS, US and US-E groups, respectively. Overall infection rate was 4.7%; NS-2.1%, US-3.0% and US-E-6.7% (p = 0.057). Four percentage of men and 6.6% of women had postoperative UTI (p = 0.22). Within the group of men infection rates were 0, 2.4 and 6.4% for the NS, US and US-E groups, respectively (p = 0.01). For women, UTI rates were 7.5, 4.0 and 8.5% in the NS, US and US-E groups, respectively (p = 0.6). Infection rates were 20 and 3.9% (p = 0.001) for patients with extraction strings for >8 and <8 days. In multivariate analysis the presence of an extraction string was found to be a risk factor for infection OR 7.7 (1.01-58.9, 95% CI, p = 0.049) along with renal stone location OR 5.09 (2.1-12.05, 95% CI, p < 0.001). No statistically significant difference was found between overall infections rates for patients with and without extraction strings, and such difference was found within the male group, suggesting extraction strings in men may increase the risk of infection.

  16. Cost-effectiveness analysis of stent type in endoscopic treatment of gastric leak after laparoscopic sleeve gastrectomy.

    PubMed

    Cosse, C; Rebibo, L; Brazier, F; Hakim, S; Delcenserie, R; Regimbeau, J M

    2018-04-01

    Gastric leak is the most feared surgical postoperative complication after sleeve gastrectomy. An endoscopic procedure is usually required to treat the leak. No data are available on the cost-effectiveness of different stent types in this procedure. Between April 2005 and July 2016, patients with a confirmed gastric leak undergoing endoscopic treatment using a covered stent (CS) or double-pigtail stent (DPS) were included. The primary objective of the study was to assess overall costs of the stent types after primary sleeve gastrectomy. Secondary objectives were the cost-effectiveness of each stent type expressed as an incremental cost-effectiveness ratio (ICER); the incremental net benefit; the probability of efficiency, defined as the probability of being cost-effective at a threshold of €30 000, and identification of the key drivers of ICER derived from a multivariable analysis. One hundred and twelve patients were enrolled. The overall mean costs of gastric leak were €22 470; the mean(s.d.) cost was €24 916(12 212) in the CS arm and €20 024(3352) in the DPS arm (P = 0·018). DPS was more cost-effective than CS (ICER €4743 per endoscopic procedure avoided), with an incremental net benefit of €25 257 and a 27 per cent probability of efficiency. Key drivers of the ICER were the inpatient ward after diagnosis of gastric leak (surgery versus internal medicine), type of institution (private versus public) and duration of hospital stay per endoscopic procedure. DPS for the treatment of gastric leak is more cost-effective than CS and should be proposed as the standard regimen whenever possible. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  17. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    PubMed

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  18. External Ventricular Drain and Hemorrhage in Aneurysmal Subarachnoid Hemorrhage Patients on Dual Antiplatelet Therapy: A Retrospective Cohort Study.

    PubMed

    Hudson, Joseph S; Prout, Benjamin S; Nagahama, Yasunori; Nakagawa, Daichi; Guerrero, Waldo R; Zanaty, Mario; Chalouhi, Nohra; Jabbour, Pascal; Dandapat, Sudeepta; Allan, Lauren; Ortega-Gutierrez, Santiago; Samaniego, Edgar A; Hasan, David

    2018-04-11

    Stenting and flow diversion for aneurysmal sub arachnoid hemorrhage (aSAH) require the use of dual antiplatelet therapy (DAPT). To investigate whether DAPT is associated with hemorrhagic complication following placement of external ventricular drains (EVD) in patients with aSAH. Rates of radiographically identified hemorrhage associated with EVD placement were compared between patients who received DAPT for stenting or flow diversion, and patients who underwent microsurgical clipping or coiling and did not receive DAPT by way of a backward stepwise multivariate analysis. Four hundred forty-three patients were admitted for aSAH management. Two hundred ninety-eight patients required placement of an EVD. One hundred twenty patients (40%) were treated with stent-assisted coiling or flow diversion and required DAPT, while 178 patients (60%) were treated with coiling without stents or microsurgical clipping and did not receive DAPT. Forty-two (14%) cases of new hemorrhage along the EVD catheter were identified radiographically. Thirty-two of these hemorrhages occurred in patients on DAPT, while 10 occurred in patients without DAPT. After multivariate analysis, DAPT was significantly associated with radiographic hemorrhage [odds ratio: 4.92, 95% confidence interval: 2.45-9.91, P = .0001]. We did not observe an increased proportion of symptomatic hemorrhage in patients receiving DAPT (10 of 32 [31%]) vs those without (5 of 10 [50%]; P = .4508). Patients with aSAH who receive stent-assisted coiling or flow diversion are at higher risk for radiographic hemorrhage associated with EVD placement. The timing between EVD placement and DAPT initiation does not appear to be of clinical significance. Stenting and flow diversion remain viable options for aSAH patients.

  19. Treatment of esophageal anastomotic leakage with self-expanding metal stents: analysis of risk factors for treatment failure

    PubMed Central

    Persson, Saga; Rouvelas, Ioannis; Kumagai, Koshi; Song, Huan; Lindblad, Mats; Lundell, Lars; Nilsson, Magnus; Tsai, Jon A.

    2016-01-01

    Background and study aim: The endoscopic placement of self-expandable metallic esophageal stents (SEMS) has become the preferred primary treatment for esophageal anastomotic leakage in many institutions. The aim of this study was to investigate possible risk factors for failure of SEMS-based therapy in patients with esophageal anastomotic leakage. Patients and methods: Beginning in 2003, all patients with an esophageal leak were initially approached and assessed for temporary closure with a SEMS. Until 2014, all patients at the Karolinska University Hospital with a leak from an esophagogastric or esophagojejunal anastomosis were identified. Data regarding the characteristics of the patients and leaks and the treatment outcomes were compiled. Failure of the SEMS treatment strategy was defined as death due to the leak or a major change in management strategy. The risk factors for treatment failure were analyzed with simple and multivariable logistic regression statistics. Results: A total of 447 patients with an esophagogastric or esophagojejunal anastomosis were identified. Of these patients, 80 (18 %) had an anastomotic leak, of whom 46 (58 %) received a stent as first-line treatment. In 29 of these 46 patients, the leak healed without any major change in treatment strategy. Continuous leakage after the application of a stent, decreased physical performance preoperatively, and concomitant esophagotracheal fistula were identified as independent risk factors for failure with multivariable logistic regression analysis. Conclusion: Stent treatment for esophageal anastomotic leakage is successful in the majority of cases. Continuous leakage after initial stent insertion, decreased physical performance preoperatively, and the development of an esophagotracheal fistula decrease the probability of successful treatment. PMID:27092321

  20. One year clinical outcomes in patients with insulin-treated diabetes mellitus and non-insulin-treated diabetes mellitus compared to non-diabetics after deployment of the bio-engineered COMBO stent.

    PubMed

    Kalkman, Deborah N; Woudstra, Pier; den Heijer, Peter; Menown, Ian B A; Erglis, Andrejs; Suryapranata, Harry; Arkenbout, Karin E; Iñiguez, Andrés; van 't Hof, Arnoud W J; Muller, Philippe; Tijssen, Jan G; de Winter, Robbert J

    2017-01-01

    The COMBO stent is a novel sirolimus-eluting stent with a luminal anti-CD34+ antibody layer to promote vessel healing. No data is currently available on clinical outcomes after treatment with this novel bio-engineered device in diabetic patients. We evaluate clinical outcomes at twelve months after COMBO stent placement in patients without diabetes mellitus (non-DM), patients with non-insulin-treated diabetes mellitus (nITDM) and patients with insulin-treated diabetes mellitus (ITDM). This study is a pre-specified subgroup analysis of the 1000 patient all-comers REMEDEE Registry. The primary endpoint is target lesion failure (TLF), which is a combined endpoint consisting of cardiac death, target vessel-myocardial infarction (tv-MI) and target lesion revascularization (TLR) at twelve months follow-up. Kaplan Meier method is used with log rank to compare outcomes between groups. This subgroup analysis includes 807 non-DM, 117 nITDM and 67 ITDM. Kaplan-Meier estimates for TLF at twelve months are 4.4% in non-DM, 6.8% in nITDM and 20.3% in ITDM, p<0.001 (non-DM vs nITDM p=0.244, non-DM vs ITDM p<0.001). This study gives the first insight into the impact of insulin-treated diabetes mellitus on clinical outcome of patients treated with the novel COMBO stent. At one year after COMBO stent placement significantly higher rates of target lesion failure are seen in patients with ITDM compared to patients with nITDM and patients without DM. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Efficacy and safety of a biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in treating de novo coronary artery disease: A pooled analysis of the CREDIT II and CREDIT III trials.

    PubMed

    Wang, Geng; Wang, Heyang; Xu, Bo; Yang, Yuejin; Yang, Zhiming; Li, Hui; Zhang, Zheng; Wang, Haichang; Yang, Lixia; Han, Yaling

    2017-03-01

    The safety and efficacy of the second-generation biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in daily clinical practice remains unknown. Additionally, to meet the China Food and Drug Administration requirements, we conducted an objective performance criterion study from the CREDIT II and CREDIT III trials. CREDIT II was a randomized trial comparing the EXCEL2 versus EXCEL stent in patients with up to 2 de novo coronary lesions. CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCEL2 in broad types of de novo coronary artery lesions. This pooled analysis included patients in the CREDIT III and EXCEL2 arm of the CREDIT II trial. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinical indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. A total of 833 patients were included, consisting of 625 in the CREDIT III trial and 208 in the EXCEL2 arm of the CREDIT II trial. Twelve-month TLF occurred in 6.1% patients, cardiac death in 0.4%, TV-MI in 5%, and CI-TLR in 1.1%. Additionally, 64 (7.7%) PoCE and 3 probable late stent thromboses (0.4%) were recorded. EXCEL2 stent met the objective performance criterion on efficacy and safety with a low level of 12-month TLF as well as stent thrombosis when treating patients with de novo coronary lesions. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Stented ureterovesical anastomosis in renal transplantation: does it influence the rate of urinary tract infections?

    PubMed

    Mathe, Zoltan; Treckmann, J W; Heuer, M; Zeiger, A; Sauerland, S; Witzke, O; Paul, A

    2010-01-01

    Our objective was to evaluate the impact of routine use of double-J stents on the incidence of urinary tract infection after renal transplantation. We conducted a retrospective-comparative single-centre study in 310 consecutive adult deceased donor kidney recipients transplanted from 2002 to 2006. Patients were divided in two groups, with or without urinary stent implantation. To evaluate the predictive factors for UTI, donor and recipients pre- and post-transplantation data were analysed. Early urological complications and renal function within 12 months of transplantation were included as well. A total of 157 patients were enrolled to a stent (ST) and 153 patients to a no-stent (NST) group. The rate of urinary tract infection at three months was similar between the two groups (43.3% ST vs. 40.1% NST, p = 0.65). Of the identified pathogens Enterococcus and Escherichia coli were the most common species. In multivariate analysis neither age nor immunosuppressive agents, BMI or diabetes seemed to have influence on the rate of UTI. When compared to males, females had a significantly higher risk for UTI (54.0% vs. 33.5%). Prophylactic stenting of the ureterovesical anastomosis does not increase the risk of urinary tract infection in the early postoperative period.

  3. Stented ureterovesical anastomosis in renal transplantation: does it influence the rate of urinary tract infections?

    PubMed Central

    2010-01-01

    Objective Our objective was to evaluate the impact of routine use of double-J stents on the incidence of urinary tract infection after renal transplantation. Methods We conducted a retrospective-comparative single-centre study in 310 consecutive adult deceased donor kidney recipients transplanted from 2002 to 2006. Patients were divided in two groups, with or without urinary stent implantation. To evaluate the predictive factors for UTI, donor and recipients pre- and post-transplantation data were analysed. Early urological complications and renal function within 12 months of transplantation were included as well. Results A total of 157 patients were enrolled to a stent (ST) and 153 patients to a no-stent (NST) group. The rate of urinary tract infection at three months was similar between the two groups (43.3% ST vs. 40.1% NST, p = 0.65). Of the identified pathogens Enterococcus and Escherichia coli were the most common species. In multivariate analysis neither age nor immunosuppressive agents, BMI or diabetes seemed to have influence on the rate of UTI. When compared to males, females had a significantly higher risk for UTI (54.0% vs. 33.5%). Conclusion Prophylactic stenting of the ureterovesical anastomosis does not increase the risk of urinary tract infection in the early postoperative period. PMID:20696641

  4. Fatigue Assessment of Nickel-Titanium Peripheral Stents: Comparison of Multi-Axial Fatigue Models

    NASA Astrophysics Data System (ADS)

    Allegretti, Dario; Berti, Francesca; Migliavacca, Francesco; Pennati, Giancarlo; Petrini, Lorenza

    2018-03-01

    Peripheral Nickel-Titanium (NiTi) stents exploit super-elasticity to treat femoropopliteal artery atherosclerosis. The stent is subject to cyclic loads, which may lead to fatigue fracture and treatment failure. The complexity of the loading conditions and device geometry, coupled with the nonlinear material behavior, may induce multi-axial and non-proportional deformation. Finite element analysis can assess the fatigue risk, by comparing the device state of stress with the material fatigue limit. The most suitable fatigue model is not fully understood for NiTi devices, due to its complex thermo-mechanical behavior. This paper assesses the fatigue behavior of NiTi stents through computational models and experimental validation. Four different strain-based models are considered: the von Mises criterion and three critical plane models (Fatemi-Socie, Brown-Miller, and Smith-Watson-Topper models). Two stents, made of the same material with different cell geometries are manufactured, and their fatigue behavior is experimentally characterized. The comparison between experimental and numerical results highlights an overestimation of the failure risk by the von Mises criterion. On the contrary, the selected critical plane models, even if based on different damage mechanisms, give a better fatigue life estimation. Further investigations on crack propagation mechanisms of NiTi stents are required to properly select the most reliable fatigue model.

  5. Chemoembolization and stenting combined with iodine-125 seed strands for the treatment of hepatocellular carcinoma with inferior vena cava obstruction

    PubMed Central

    LI, WENHUI; DAI, ZHENYU; YAO, LIZHENG; LUO, JIANJUN; YAN, ZHIPING

    2015-01-01

    The aim of the present study was to investigate the efficacy and safety of stenting combined with radioactive iodine-125 seed strands following chemoembolization for the treatment of patients with hepatocellular carcinoma and inferior vena cava (IVC) obstruction. A retrospective analysis was conducted of 52 hepatocellular carcinoma patients with IVC obstruction. All patients received chemoembolization of tumor-supplying arteries and IVC stents, and 18 patients additionally received iodine-125 seed strands, which were fixed to the stents. Improvement of IVC obstruction and the tumor response rates were compared between the two groups with a median follow-up time of 2.5 months. In both groups the stents were successfully deployed. At the 2-month post-procedural follow-up, the mean diameter of the IVC obstruction site, the mean pressure difference between the distal IVC obstructive segment and the right atrium as well as the obstruction scoring did not differ significantly between the two groups. By contrast, the tumor response rate of the iodine-125 seed strand group was 94.4%, whereas for the group without iodine-125 seed strands it was 35.3% (P<0.001). The combination of stent and iodine-125 seed strands was effective and safe for the treatment of hepatocellular carcinoma with IVC obstruction. PMID:26622424

  6. Bile Flow Phantom Model and Animal Bile Duct Dilation Model for Evaluating Biliary Plastic Stents with Advanced Hydrophilic Coating

    PubMed Central

    Kwon, Chang-Il; Kim, Gwangil; Jeong, Seok; Lee, Won Seop; Lee, Don Haeng; Ko, Kwang Hyun; Hong, Sung Pyo; Hahm, Ki Baik

    2016-01-01

    Background/Aims The efforts to improve biliary plastic stents (PSs) for decreasing biofilm formation and overcome short patency time have been continued. The aim of this study is to evaluate the effect of advanced hydrophilic coating for patency and biodurability of PS. Methods Using an in vitro bile flow phantom model, we compared patency between prototype PS with hydrophilic coating (PS+HC) and prototype PS without hydrophilic coating (PS−HC). We performed an analysis of the degree of luminal narrowing by microscopic examination. Using an in vivo swine bile duct dilation model made by endoscopic papillary closure and stent insertion, we evaluated biodurability of hydrophilic coating. Results In the phantom model, PS+HC showed less biofilm formation and luminal narrowing than PS−HC at 8 weeks (p<0.05). A total of 31 stents were inserted into the dilated bile duct of seven swine models, and 24 stents were successfully retrieved 8 weeks later. There was no statistical difference of stent patency between the polyethylene PS+HC and the polyurethane PS+HC. The biodurability of hydrophilic coating was sustained up to 8 weeks, when assessing the coating layer by scanning electron microscopy examination. Conclusions Advanced hydrophilic coating technology may extend the patency of PS compared to uncoated PS. PMID:27021507

  7. Fatigue Assessment of Nickel-Titanium Peripheral Stents: Comparison of Multi-Axial Fatigue Models

    NASA Astrophysics Data System (ADS)

    Allegretti, Dario; Berti, Francesca; Migliavacca, Francesco; Pennati, Giancarlo; Petrini, Lorenza

    2018-02-01

    Peripheral Nickel-Titanium (NiTi) stents exploit super-elasticity to treat femoropopliteal artery atherosclerosis. The stent is subject to cyclic loads, which may lead to fatigue fracture and treatment failure. The complexity of the loading conditions and device geometry, coupled with the nonlinear material behavior, may induce multi-axial and non-proportional deformation. Finite element analysis can assess the fatigue risk, by comparing the device state of stress with the material fatigue limit. The most suitable fatigue model is not fully understood for NiTi devices, due to its complex thermo-mechanical behavior. This paper assesses the fatigue behavior of NiTi stents through computational models and experimental validation. Four different strain-based models are considered: the von Mises criterion and three critical plane models (Fatemi-Socie, Brown-Miller, and Smith-Watson-Topper models). Two stents, made of the same material with different cell geometries are manufactured, and their fatigue behavior is experimentally characterized. The comparison between experimental and numerical results highlights an overestimation of the failure risk by the von Mises criterion. On the contrary, the selected critical plane models, even if based on different damage mechanisms, give a better fatigue life estimation. Further investigations on crack propagation mechanisms of NiTi stents are required to properly select the most reliable fatigue model.

  8. Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    PubMed

    Benard, Nicolas; Perrault, Robert; Coisne, Damien

    2006-08-01

    In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution of wall shear stress (WSS) exerted by the fluid on the internal vessel surface. Our numerical model is based on a full 3D stent mesh. Rigid wall and stationary inflow conditions are applied. Newtonian behavior, non-newtonian model based on Carreau-Yasuda relation and a characteristic newtonian value defined with flow representative parameters are introduced in this research. Non-newtonian flow generates an alteration of near wall viscosity norms compared to newtonian. Maximal WSS values are located in the center part of stent pattern structure and minimal values are focused on the proximal stent wire surface. A flow rate increase emphasizes fluid perturbations, and generates a WSS rise except for interstrut area. Nevertheless, a local quantitative analysis discloses an underestimation of WSS for modelisation using a newtonian blood flow, with clinical consequence of overestimate restenosis risk area. Characteristic viscosity introduction appears to present a useful option compared to rheological modelisation based on experimental data, with computer time gain and relevant results for quantitative and qualitative WSS determination.

  9. The use of retrievable fully covered self-expanding metal stent in refractory postoperative restenosis of benign esophageal stricture in children.

    PubMed

    Zhang, Jie; Ren, Lixin; Huo, Jirong; Zhu, Zhiyuan; Liu, Deliang

    2013-11-01

    This study analyzes the efficacy and safety of a retrievable, fully covered self-expanding metal stent (cSEMS) in the treatment of refractory benign esophageal restenosis in children. This is a retrospective analysis of the application of a newly designed cSEMS in treating refractory benign postoperative restenosis in five children with ages ranging from 16 months to 8 years. Efficacy and safety were evaluated during the follow-up period. cSEMS with or without an antireflux valve at the distal end were successfully placed and removed in five children. These five patients were followed up for 4-12 months after stent removal. Among the five patients, ulcerative stricture was observed in two patients because of reflux esophagitis, while three patients showed no signs of stricture recurrence. Stent migration was observed in three patients, two of which required the stent to be reset. The narrow esophagus was successfully expended to a diameter of 12-13 mm. Besides the observation of mild granulation tissue growth in one case, no severe complications were observed during surgery and after stent placement. Our study suggests that a retrievable, fully covered SEMS is safe and partially effective for treating refractory benign postoperative esophageal restenosis in children during short-term observation. © 2013.

  10. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    PubMed

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  11. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less

  12. Bench-top Comparison of Physical Properties of 4 Commercially-Available Self-Expanding Intracranial Stents

    PubMed Central

    Cho, Su-hee; Jo, Won-il; Jo, Ye-eun; Yang, Ku Hyun; Park, Jung Cheol

    2017-01-01

    Purpose To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. Materials and Methods Four different types of stents that are currently being used for cerebral aneurysm embolization were prepared (two stents per type). Two were laser-cut stents (Neuroform and Enterprise) and two were braided from a single nitinol wire (LEO and LVIS stents). All were subjected to quantitative measurements of stent size, pore density, metal coverage, the force needed to load, push, and deploy the stent, radial force on deployment, surface roughness, and corrosion resistance. Results Compared to their nominal diameters, all stents had greater diameters after deployment. The length generally decreased after deployment. This was particularly marked in the braided stents. The braided stents also had higher pore densities than the laser-cut stents. Metal coverage was highest in the LEO stent (14%) and lowest in the Enterprise stent (5%). The LIVS stent had the highest microcatheter loading force (81.5 gf). The LEO stent had the highest passage force (55.0 gf) and deployment force (78.9 gf). The LVIS and LEO stents had the highest perpendicular (37.1 gf) and circumferential (178.4 gf) radial forces, respectively. The Enterprise stent had the roughest stent wire, followed by the LVIS, LEO, and Neuroform stents. Conclusion The four neurovascular stent types differed in terms of morphological and physical characteristics. An understanding of this diversity may help to decide which stent is most suitable for specific clinical situations. PMID:28316867

  13. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    PubMed Central

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  14. Chemical etching of nitinol stents.

    PubMed

    Katona, Bálint; Bognár, Eszter; Berta, Balázs; Nagy, Péter; Hirschberg, Kristóf

    2013-01-01

    At present the main cause of death originates from cardiovascular diseases. Primarily the most frequent cause is vessel closing thus resulting in tissue damage. The stent can help to avoid this. It expands the narrowed vessel section and allows free blood flow. The good surface quality of stents is important. It also must have adequate mechanical characteristics or else it can be damaged which can easily lead to the fracture of the implant. Thus, we have to consider the importance of the surface treatment of these implants. In our experiments the appropriate design was cut from a 1.041 mm inner diameter and 0.100 mm wall thickness nitinol tube by using Nd:YAG laser device. Then, the stent was subjected to chemical etching. By doing so, the burr created during the laser cutting process can be removed and the surface quality refined. In our research, we changed the time of chemical etching and monitored the effects of this parameter. The differently etched stents were subjected to microscopic analysis, mass measurement and in vivo environment tests. The etching times that gave suitable surface and mechanical features were identified.

  15. Restenosis and risk of stroke after stenting or endarterectomy for symptomatic carotid stenosis in the International Carotid Stenting Study (ICSS): secondary analysis of a randomised trial.

    PubMed

    Bonati, Leo H; Gregson, John; Dobson, Joanna; McCabe, Dominick J H; Nederkoorn, Paul J; van der Worp, H Bart; de Borst, Gert J; Richards, Toby; Cleveland, Trevor; Müller, Mandy D; Wolff, Thomas; Engelter, Stefan T; Lyrer, Philippe A; Brown, Martin M

    2018-05-31

    The risk of stroke associated with carotid artery restenosis after stenting or endarterectomy is unclear. We aimed to compare the long-term risk of restenosis after these treatments and to investigate if restenosis causes stroke in a secondary analysis of the International Carotid Stenting Study (ICSS). ICSS is a parallel-group randomised trial at 50 tertiary care centres in Europe, Australia, New Zealand, and Canada. Patients aged 40 years or older with symptomatic carotid stenosis measuring 50% or more were randomly assigned either stenting or endarterectomy in a 1:1 ratio. Randomisation was computer-generated and done centrally, with allocation by telephone or fax, stratified by centre, and with minimisation for sex, age, side of stenosis, and occlusion of the contralateral carotid artery. Patients were followed up both clinically and with carotid duplex ultrasound at baseline, 30 days after treatment, 6 months after randomisation, then annually for up to 10 years. We included patients whose assigned treatment was completed and who had at least one ultrasound examination after treatment. Restenosis was defined as any narrowing of the treated artery measuring 50% or more (at least moderate) or 70% or more (severe), or occlusion of the artery. The degree of restenosis based on ultrasound velocities and clinical outcome events were adjudicated centrally; assessors were masked to treatment assignment. Restenosis was analysed using interval-censored models and its association with later ipsilateral stroke using Cox regression. This trial is registered with the ISRCTN registry, number ISRCTN25337470. This report presents a secondary analysis, and follow-up is complete. Between May, 2001, and October, 2008, 1713 patients were enrolled and randomly allocated treatment (855 were assigned stenting and 858 endarterectomy), of whom 1530 individuals were followed up with ultrasound (737 assigned stenting and 793 endarterectomy) for a median of 4·0 years (IQR 2·3-5·0). At least moderate restenosis (≥50%) occurred in 274 patients after stenting (cumulative 5-year risk 40·7%) and in 217 after endarterectomy (29·6%; unadjusted hazard ratio [HR] 1·43, 95% CI 1·21-1·72; p<0·0001). Patients with at least moderate restenosis (≥50%) had a higher risk of ipsilateral stroke than did individuals without restenosis in the overall patient population (HR 3·18, 95% CI 1·52-6·67; p=0·002) and in the endarterectomy group alone (5·75, 1·80-18·33; p=0·003), but no significant increase in stroke risk after restenosis was recorded in the stenting group (2·03, 0·77-5·37; p=0·154; p=0·10 for interaction with treatment). No difference was noted in the risk of severe restenosis (≥70%) or subsequent stroke between the two treatment groups. At least moderate (≥50%) restenosis occurred more frequently after stenting than after endarterectomy and increased the risk for ipsilateral stroke in the overall population. Whether the restenosis-mediated risk of stroke differs between stenting and endarterectomy requires further research. Medical Research Council, the Stroke Association, Sanofi-Synthélabo, and the European Union. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access Article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  16. Malignant Ureteral Obstruction: Functional Duration of Metallic versus Polymeric Ureteral Stents

    PubMed Central

    Chow, Po-Ming; Chiang, I-Ni; Chen, Chia-Yen; Huang, Kuo-How; Hsu, Jui-Shan; Wang, Shuo-Meng; Lee, Yuan-Ju; Yu, Hong-Jeng; Pu, Yeong-Shiau; Huang, Chao-Yuan

    2015-01-01

    Background Ureteral obstruction caused by extrinsic compression is often associated with intra-abdominal cancers. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. Novel designs of ureteral stents made of different materials have been invented to achieve better drainage. In this study, we described the functional outcomes of a Resonance metallic ureteral stent (Cook Medical, Bloomington, Indiana, USA) in patients with malignant ureteral obstruction and compare the functional duration of Resonance stents with regular polymeric stents in the same cohort. Methods Cancer patients who received polymeric stents and subsequent Resonance stents for ureteral obstruction between July 2009 and November 2012 were included in a chart review. Stent failure was detected by clinical symptoms, imaging studies, and renal function tests. The functional durations of each stent were calculated, and possible factors affecting stent patency were investigated. Results A total of 50 stents were successfully inserted into 50 ureteral units in 42 patients with malignant ureteral obstruction. There were 7 antegrade stents and 43 retrograde stents. There were no major complications. Stent-related symptoms were similar in both kinds of stents. After polymeric stents were replaced with Resonance metallic stents, hydronephrosis subsided or remained stable in 90% (45/50) of the ureteral units. Serum creatinine decreased or remained stable in 90% (38/42) of these patients. The Resonance stent exhibited a mean increase in functional duration of 4 months compared with the polymeric stents (p<0.0001), and 50% (25/50) of the Resonance stents exhibited a significant increase in functional duration (more than 3 months). Pre-operative serum creatinine < 2 was associated with a substantial increase in stent duration. Conclusions Resonance stents are effective and safe in relieving malignant ureteral obstructions after polymeric stents failure. Resonance stents can provide a longer functional duration than polymeric stents and should be offered as an option for internal drainage. PMID:26267140

  17. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    PubMed

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P < .001) to predict >or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  18. Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis.

    PubMed

    Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K

    2016-06-01

    Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with coronary artery disease: three-year follow-up of the COMPARE II (Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent) trial.

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Puricel, Serban; Slagboom, Ton; Goy, Jean-Jacques; den Heijer, Peter; van der Ent, Martin

    2015-07-01

    The aim of this analysis was to compare the long-term safety and efficacy of the biodegradable polymer biolimus-eluting stent (BES) with that of the durable polymer everolimus-eluting stent (EES). The COMPARE II study was a prospective, randomised, multicentre, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BES or EES. The pre-specified endpoint at three years was major adverse cardiac events (MACE), a composite of cardiac death, non-fatal myocardial infarction (MI), or target vessel revascularisation (TVR). Moreover, the combined endpoint all-cause death or MI was analysed as a safety, and TVR as an efficacy measure. Three-year follow-up was available in 2,683 patients (99.1%). At three years, MACE occurred in 213 patients (11.9%) in the BES group and in 101 patients (11.1 %) in the EES group (p=0.57). The rate of the combined safety endpoint all-cause death or MI was 9.3% in the BES group vs. 8.4% (p=0.52), while the efficacy measure TVR was 7.6% in BES vs. 6.5% (p=0.27). Interestingly, definite stent thrombosis rates did not differ between groups (1.2% for BES vs. 0.8%, p=0.33). At three-year follow-up, MACE as well as safety and efficacy measures including stent thrombosis were not statistically different between the biodegradable polymer-coated BES and the durable polymer-coated EES. ClinicalTrials.gov Identifier: NCT01233453.

  20. Technical and Clinical Outcomes Following Colonic Stenting: A Seven-Year Analysis of 268 Procedures.

    PubMed

    Little, M W; Oakley, T; Briggs, J H; Sutcliffe, J A; Allouni, A K; Makris, G; Bratby, M J; Tapping, C R; Patel, R; Wigham, A; Anthony, S; Phillips-Hughes, J; Uberoi, R

    2016-10-01

    To assess the factors contributing to the technical and clinical success of colorectal stenting for large bowel obstruction. 268 cases of colonic stenting for large bowel obstruction were performed in 249 patients of mean age of 72 years (28-98) between 2006 and 2013. The majority of strictures were due to malignant disease, 244/268 (91 %). Diverticular strictures accounted for 24/268 (9 %). Overall technical success rate was 81 % (217/268), with a clinical success rate of 65 % (174/268). Duration of symptoms ranged from 0 to 180 days (mean 8 days). Technical success rate was seen to decrease with increasing symptom duration. For symptom duration of less than 1 week, technical success was 85.4 % (181/212) versus 69.6 % (39/56) for those with symptoms of greater than a week (p < 0.05). Clinical success rates fell from 71.3 % (107/150) to 59.3 % (70/118) (p < 0.05) when attempting to stent lesions of greater than 5 cm. There was also a significant reduction in clinical success when stenting lesions on a bend rather than a straight segment of colon 75.7 % (109/144) versus 59.7 % (74/124) (p < 0.05). A total of 20 (7.46 %) perforations were identified during the study. Stent migration occurred in 6.6 % of cases. In-stent stenosis occurred in 3.3 %. The overall 30-day all cause mortality rate was 9 %. Lesion size, location and duration of obstructive symptoms are statistically significant determinants of patient outcome. These factors could be used to advise patient selection for colonic stenting or direct progression to surgical intervention.

  1. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    PubMed

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  2. Distribution of angiographic measures of restenosis after drug-eluting stent implantation.

    PubMed

    Byrne, R A; Eberle, S; Kastrati, A; Dibra, A; Ndrepepa, G; Iijima, R; Mehilli, J; Schömig, A

    2009-10-01

    A bimodal distribution of measures of restenosis has been demonstrated at 6-8 months after bare metal stent implantation. Drug-eluting stent (DES) treatment has attenuated the impact of certain factors (eg, diabetes) on restenosis but its effect on the distribution of indices of restenosis is not known. To perform a detailed analysis of the metrics of restenosis indices after DES implantation. Design, settings, Prospective observational study of patients undergoing DES implantation (Cypher, sirolimus-eluting stent; or Taxus, paclitaxel-eluting stent) at two German centres, with repeat angiography scheduled at 6-8 months after coronary stenting. In-stent late luminal loss (LLL) and in-segment percentage diameter stenosis (%DS) as determined by quantitative coronary angiography at recatheterisation. Paired cineangiograms were available for 2057 patients. Overall mean (SD) LLL was 0.31 (0.50) mm; mean (SD) %DS was 30.3 (15.7)%. Distribution of both LLL and %DS differed significantly from normal (Kolmogorov-Smirnov test; p<0.001 for each). For both parameters a mixed distribution model better described the data (likelihood ratio test with 3df; p<0.001 for each). This consisted of two normally distributed subpopulations with means (SD) of 0.10 (0.25) mm and 0.69 (0.60) mm for LLL, and means (SD) of 22.2 (8.6)% and 40.1 (16.6)% for %DS. The results were consistent across subgroups of DES type, "on-label" versus "off-label" indication, and presence or absence of diabetes. LLL and %DS at follow-up angiography after DES implantation have a complex mixed distribution that may be accurately represented by a bimodal distribution model. The introduction of DES treatment has not resulted in elimination of a variable propensity to restenosis among subpopulations of patients with stented lesions.

  3. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    PubMed

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to mitigate the increased risk of stent thrombosis associated with ACS. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions [SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT III]; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT IV]; NCT00307047; A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice: the COMPARE Trial [COMPARE]; NCT01016041). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    PubMed Central

    Guan, Ying; Wang, Lu; Lin, Jing; King, Martin W.

    2016-01-01

    Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft. PMID:28773781

  5. Cost Sensitivity Analysis for Consolidated Interim Storage of Spent Fuel: Evaluating the Effect of Economic Environment Parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cumberland, Riley M.; Williams, Kent Alan; Jarrell, Joshua J.

    This report evaluates how the economic environment (i.e., discount rate, inflation rate, escalation rate) can impact previously estimated differences in lifecycle costs between an integrated waste management system with an interim storage facility (ISF) and a similar system without an ISF.

  6. 78 FR 48503 - Proposed Revision to Missiles Generated by Extreme Winds

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ...-0800, ``Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR..., ``Design-Basis Hurricane and Hurricane Missiles for Nuclear Power Plants,'' and Interim Staff Guidance DC... and Hurricane Missiles for Nuclear Power Plants'' (ADAMS, Accession No. ML110940300), and Interim...

  7. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    PubMed

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  8. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    PubMed

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P < 0.05) at 1.5 and 3 T. Maximum visible stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  9. Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials.

    PubMed

    Bundhun, Pravesh Kumar; Yanamala, Chandra Mouli; Huang, Wei-Qiang

    2017-03-16

    Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 - 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 - 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 - 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 - 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 - 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 - 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 - 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 - 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 - 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 - 1.82; P = 0.78 respectively. At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late definite or probable ST. However, further trials are recommended to assess the effects of these second-generation DES during the long-term.

  10. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.

    PubMed

    Poerner, Tudor C; Otto, Sylvia; Gassdorf, Johannes; Nitsche, Kristina; Janiak, Florian; Scheller, Bruno; Goebel, Björn; Jung, Christian; Figulla, Hans R

    2014-12-01

    In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64±9.65% in BMS+DEB versus 4.93±9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7±7.8 versus 11.0±5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8±11.9 versus 16.9±10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5±13.8% versus 36.8±15.6%; P=0.409) was found. Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up. http://www.clinicaltrials.gov. Unique identifier: NCT01056744. © 2014 American Heart Association, Inc.

  11. Intraductal Transanastomotic Stenting in Duct-to-Duct Biliary Reconstruction after Living-Donor Liver Transplantation: A Randomized Trial.

    PubMed

    Santosh Kumar, K Y; Mathew, Johns Shaji; Balakrishnan, Dinesh; Bharathan, Viju Kumar; Thankamony Amma, Binoj Sivasankara Pillai; Gopalakrishnan, Unnikrishnan; Narayana Menon, Ramachandran; Dhar, Puneet; Vayoth, Sudheer Othiyil; Sudhindran, Surendran

    2017-12-01

    Biliary complications continue to be the "Achilles heel" of living-donor liver transplantation (LDLT). The use of biliary stents in LDLT to reduce biliary complications is a controversial issue. We performed a randomized trial to study the impact of intraductal biliary stents on postoperative biliary complications after LDLT. Of the 94 LDLTs that were performed during a period of 16 months, ABO-incompatible transplants, left lobe grafts, 3 or more bile ducts on the graft, and those requiring bilioenteric drainage were excluded. Eligible patients were randomized to either a study arm (intraductal stent, n = 31) or a control arm (no stent, n = 33) by block randomization. Stratification was done, based on the number of ducts on the graft requiring anastomosis, into single (n = 20) or 2 ducts (n = 44). Ureteric stents of 3F to 5F placed across the biliary anastomosis and exiting into the duodenum for later endoscopic removal at 3 months were used. The primary end point was postoperative bile leak. Bile leak occurred in 15 of 64 (23.4%), the incidence was higher in the stented group compared with the control group (35.5% vs 12.1%; p = 0.03). Multiplicity of bile ducts and stenting were identified as risk factors for bile leak on multivariate analysis (p = 0.031 and p = 0.032). During a median follow-up of 2 years, biliary stricture developed in 9 patients (14.1%). Postoperative bile leak is a significant risk factor for the development of biliary stricture (p = 0.003). Intraductal transanastomotic biliary stenting and multiplicity of graft ducts were identified as independent risk factors for the development of postoperative biliary complications. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  12. The predictive value of haemodynamic parameters for outcome of deep venous reconstructions in patients with chronic deep vein obstruction - A systematic review.

    PubMed

    Kurstjens, Rlm; de Wolf, Maf; Kleijnen, J; de Graaf, R; Wittens, Cha

    2017-09-01

    Objective The aim of this study was to investigate the predictive value of haemodynamic parameters on success of stenting or bypass surgery in patients with non-thrombotic or post-thrombotic deep venous obstruction. Methods EMBASE, MEDLINE and trial registries were searched up to 5 February 2016. Studies needed to investigate stenting or bypass surgery in patients with post-thrombotic obstruction or stenting for non-thrombotic iliac vein compression. Haemodynamic data needed to be available with prognostic analysis for success of treatment. Two authors, independently, selected studies and extracted data with risk bias assessment using the Quality in Prognosis Studies tool. Results Two studies using stenting and two using bypass surgery were included. Three investigated plethysmography, though results varied and confounding was not properly taken into account. Dorsal foot vein pressure and venous refill times appeared to be of influence in one study, though confounding by deep vein incompetence was likely. Another investigated femoral-central pressure gradients without finding statistical significance, though sample size was small without details on statistical methodology. Reduced femoral inflow was found to be a predictor for stent stenosis or occlusion in one study, though patients also received additional surgery to improve stent inflow. Data on prediction of haemodynamic parameters for stenting of non-thrombotic iliac vein compression were not available. Conclusions Data on the predictive value of haemodynamic parameters for success of treatment in deep venous obstructive disease are scant and of poor quality. Plethysmography does not seem to be of value in predicting outcome of stenting or bypass surgery in post-thrombotic disease. The relevance of pressure-related parameters is unclear. Reduced flow into the common femoral vein seems to be predictive for in-stent stenosis or occlusion. Further research into the predictive effect of haemodynamic parameters is warranted and the possibility of developing new techniques that evaluate various haemodynamic aspects should be explored.

  13. Stent placement for benign colonic stenosis: case report, review of the literature, and animal pilot data.

    PubMed

    Geiger, Timothy M; Miedema, Brent W; Tsereteli, Zurab; Sporn, Emanuel; Thaler, Klaus

    2008-10-01

    Permanent metal stent placement for malignant intestinal obstruction has been proven to be efficient. Temporary stents for benign conditions of the colon and rectum are less studied. This is a case study, review of the literature, and observation from an animal model on placement of stents in the colorectum for benign disease. A 55-year-old man presented with recurrent obstructions from a benign stricture of the distal sigmoid colon. After failed balloon dilations, a polyester coated stent was placed. The purpose of the stent was to improve symptoms and avoid surgery. The stent was expelled after 5 days. We conducted a literature review of stents placed for benign colorectal strictures and an animal study to evaluate stent migration. In the literature, there were 53 reports of uncovered metal stents, four covered metal stents, and six polyester stents. Patency rates were 71%, and migration rate was 43%. Migration occurred earlier with polyester stents (mean=8 days) versus covered (32 days) or uncovered metal stents (112 days). Severe complications were seen in 23% of patients. Four 45-kg pigs underwent rectosigmoid transection with a 21-mm anastomosis and endoscopic placement of a Polyflex stent. Two stents were secured with suture. Stents without fixation were expelled within 24 h of surgery. Stents with fixation were expelled between postoperative days 2 and 14. Stents for the treatment of benign colorectal strictures are safe, with comparable patency rates between stent types. Metal stents can cause severe complications. In a pig model, covered polyester stents tend to migrate early even with fixation. Further investigation needs to focus on new stent designs and/or better fixation.

  14. Long-term outcomes and risk factors of biliary stent dysfunction after endoscopic double stenting for malignant biliary and duodenal obstructions.

    PubMed

    Matsumoto, Kazuyuki; Kato, Hironari; Tsutsumi, Koichiro; Mizukawa, Sho; Yabe, Syuntaro; Seki, Hiroyuki; Akimoto, Yutaka; Uchida, Daisuke; Tomoda, Takeshi; Yamamoto, Naoki; Horiguchi, Shigeru; Kuwaki, Kenji; Okada, Hiroyuki

    2017-07-01

    Few reports describe the endoscopic double-stenting procedure for malignant biliary and duodenal obstructions. We evaluated the clinical outcomes from double stenting, and analyzed the risk factors for biliary stent dysfunction following double stenting. Eighty-one patients who underwent endoscopic double stenting for malignant biliary and duodenal obstructions were retrospectively analyzed. We determined the stent dysfunction rate and the biliary stent dysfunction risk factors, and analyzed the endoscopic reintervention results. Overall survival time and survival time following double stenting were 365 (38-1673) days and 73 (20-954) days, respectively. After double stenting, the 3-month and 6-month duodenal stent dysfunction rates were 14% and 41%, respectively. Reintervention technical success rate was 100% (10/10), and mean gastric outlet obstruction scoring system scores improved from 0.7 to 2.4 points (P < 0.001). The 3-month and 6-month biliary stent dysfunction rates were 26% and 41%, respectively. The reintervention technical and clinical success rates were 95% (20/21) and 81% (17/21), respectively. Risk factors for biliary stent dysfunction following double stenting were events associated with duodenal stent dysfunction (odds ratio [OR], 11.1; 95% confidence interval [CI], 2.09-87.4; P = 0.0044) and the biliary stent end's location (OR, 6.93; 95% CI, 1.37-40.2; P = 0.0019). Some patients had stent dysfunction irrespective of the survival period after double stenting. Endoscopic reintervention was technically feasible and clinically effective even after double stenting. Duodenal stent dysfunction and biliary stent end's location were risk factors for biliary stent dysfunction. © 2017 Japan Gastroenterological Endoscopy Society.

  15. Application of a temporal reasoning framework tool in analysis of medical device adverse events.

    PubMed

    Clark, Kimberly K; Sharma, Deepak K; Chute, Christopher G; Tao, Cui

    2011-01-01

    The Clinical Narrative Temporal Relation Ontology (CNTRO)1 project offers a semantic-web based reasoning framework, which represents temporal events and relationships within clinical narrative texts, and infer new knowledge over them. In this paper, the CNTRO reasoning framework is applied to temporal analysis of medical device adverse event files. One specific adverse event was used as a test case: late stent thrombosis. Adverse event narratives were obtained from the Food and Drug Administration's (FDA) Manufacturing and User Facility Device Experience (MAUDE) database2. 15 adverse event files in which late stent thrombosis was confirmed were randomly selected across multiple drug eluting stent devices. From these files, 81 events and 72 temporal relations were annotated. 73 temporal questions were generated, of which 65 were correctly answered by the CNTRO system. This results in an overall accuracy of 89%. This system should be pursued further to continue assessing its potential benefits in temporal analysis of medical device adverse events.

  16. Characterization of compression behaviors of fully covered biodegradable polydioxanone biliary stent for human body: A numerical approach by finite element model.

    PubMed

    Liu, Yanhui; Zhang, Peihua

    2016-09-01

    This paper presents a study of the compression behaviors of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body by finite element method. To investigate the relationship between the compression force and structure parameter (monofilament diameter and braid-pin number), nine numerical models based on actual biliary stent were established, the simulation and experimental results are in good agreement with each other when calculating the compression force derived from both experiment and simulation results, indicating that the simulation results can be provided a useful reference to the investigation of biliary stents. The stress distribution on FCBPBSs was studied to optimize the structure of FCBPBSs. In addition, the plastic dissipation analysis and plastic strain of FCBPBSs were obtained via the compression simulation, revealing the structure parameter effect on the tolerance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    PubMed

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Outcomes of Stent Placement for Chronic Occlusion of a Filter-bearing Inferior Vena Cava in Patients with Severe Post-thrombotic Syndrome.

    PubMed

    Ye, K; Lu, X; Li, W; Yin, M; Liu, X; Qin, J; Liu, G; Jiang, M

    2016-12-01

    To evaluate the technical aspects and short-term clinical results of stent placement for chronic occlusion of a filter-bearing inferior vena cava (IVC) in patients with severe post-thrombotic syndrome (PTS). A retrospective analysis of 24 patients with severe PTS associated with occlusion of a filter-bearing IVC treated by stent placement was conducted at a single institution from January 2010 to December 2014. Patient-reported quality of life and limb Villalta scores were evaluated before and after treatment by questionnaire and clinical examination, respectively. Stent patency was evaluated by duplex Doppler ultrasound, venography, or venous computed tomographic (CT) angiography. All patients tolerated the procedure well. Nineteen patients with filter-bearing IVC and bilateral iliofemoral occlusions were treated with "double-barrel" stents, two were treated with fenestrated stents, and the remaining three patients were treated by unilateral stent placement of the iliofemoral vein and filter-bearing IVC. Quality of life and Villalta scores were significantly improved (p < .001) after the procedure. The 1-year, and 2-year cumulative primary and secondary stent patency rates were 67% and 91%, and 45% and 77%, respectively. During a median follow-up period of 27 months (range 3-55 months), the cumulative rates of complete relief of pain (visual analog scale >5) and swelling (grade 3) were 77% (13 of 17 limbs at risk) and 75% (24 of 32 limbs at risk), respectively. There were 23 limbs with active ulcers and the cumulative rate of ulcer healing at 2 years was 73%. There were no cases of clinical bleeding, symptomatic pulmonary embolism, or mortality. Recanalization of an occluded IVC filter and stent placement through the filter is a feasible and safe method for management of PTS associated with filter-bearing IVC occlusions, with acceptable short-term stent patency and clinical results. However, close follow-up after procedure is necessary because of a relatively high re-occlusion rate. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Long-Term Outcomes of Stenting the Proximal Left Anterior Descending Artery in the PROTECT Trial.

    PubMed

    Roguin, Ariel; Camenzind, Edoardo; Kerner, Arthur; Beyar, Rafael; Boersma, Eric; Mauri, Laura; Steg, Ph Gabriel; Wijns, William

    2017-03-27

    This study sought to compare the outcomes of patients undergoing drug-eluting stent implantation according to lesion location within or outside the proximal left anterior descending (LAD) artery. Proximal LAD artery involvement is considered uniquely in revascularization guidelines. The impact of LAD lesion location on long-term outcomes after revascularization is poorly understood in context of current percutaneous coronary intervention and medical therapy. Among 8,709 patients enrolled in PROTECT (Patient Related Outcomes with Endeavor Versus Cypher Stenting Trial), a multicenter percutaneous coronary intervention trial, we compared the outcomes of 2,534 patients (29.1%) (3,871 lesions [31.5%]) with stents implanted in the proximal LAD to 6,172 patients (70.9%) (8,419 lesions [68.5%]) with stents implanted outside the proximal LAD. At the 4-year follow-up, death rates were the same (5.8% vs. 5.8%; p > 0.999), but more myocardial infarctions occurred in the proximal LAD group (6.2% vs. 4.9%; p = 0.015). The rate of clinically driven target vessel failure (TVF) (14.8% vs. 13.5%; p = 0.109), major adverse cardiac event(s) (MACE) (15.0% vs. 13.7%; hazard ratio: 1.1; 95% confidence interval: 0.97 to 1.31; p = 0.139), and stent thrombosis (2.1% vs. 2.0%; p = 0.800) were similar. Drug-eluting stent type had no interaction with MACE or TVF. In multivariate analysis, the proximal LAD was a predictor of myocardial infarction (p = 0.038) but not of TVF (p = 0.149) or MACE (p = 0.069). In this study of contemporary percutaneous coronary intervention, proximal LAD location was associated with higher rates of myocardial infarction during the long-term follow-up, but there were no differences in stent thrombosis, death, TVF, or overall MACE. This finding may suggest that, in the drug-eluting stent era, proximal LAD no longer confers a different prognosis than other lesion sites. (Randomized Study Comparing Endeavor With Cypher Stents [PROTECT]; NCT00476957). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. A phase II flexible screening design allowing for interim analysis and comparison with historical control.

    PubMed

    Wu, Wenting; Bot, Brian; Hu, Yan; Geyer, Susan M; Sargent, Daniel J

    2013-07-01

    Sargent and Goldberg [1] proposed a randomized phase II flexible screening design (SG design) which took multiple characteristics of candidate regimens into consideration in selecting a regimen for further phase III testing. In this paper, we extend the SG design by including provisions for an interim analysis and/or a comparison to a historical control. By including a comparison with a historical control, a modified SG design not only identifies a more promising treatment but also assures that the regimen has a clinically meaningful level of efficacy as compared to a historical control. By including an interim analysis, a modified SG design could reduce the number of patients exposed to inferior treatment regimens. When compared to the original SG design, the modified designs increase the sample size moderately, but expand the utility of the flexible screening design substantially. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Retreatment of recanalized aneurysms after Y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature.

    PubMed

    Kono, Kenichi; Shintani, Aki; Terada, Tomoaki

    2014-01-01

    It is necessary to consider possibility of recanalization and retreatment after coil embolization for cerebral aneurysms. There is concern that retreatment for recanalized aneurysms after Y-stent-assisted coil embolization may be difficult because of double stents, especially in Y-stents with double closed-cell stents owing to narrowed structures. However, no detailed reports of retreatment after Y-stent have been reported. Between July 2010 and June 2013, we treated four aneurysms with Y-stent-assisted coil embolization using Enterprise closed-cell stents. Recanalization occurred in one case (25%), and retreatment was performed. We easily navigated a microcatheter into the target portions of the aneurysm through the Y-stent and occluded the aneurysm with coils. Additionally, by systematically searching in PubMed, we found 105 cases of Y-stent-assisted coil embolization using Enterprise stents or Neuroform stents with more than 6 months of follow-up. Among them, retreatment was performed in 10 cases (9.5%). There were no significant differences in retreatment rates among different stent combinations (P=0.91; Fisher's exact test). In conclusion, navigation of a microcatheter into the aneurysm through the Y-stent with double Enterprise stents was feasible, and retreatment rates after Y-stent-assisted coiling may not depend on stent combinations.

  2. [Numerical simulation of the effect of virtual stent release pose on the expansion results].

    PubMed

    Li, Jing; Peng, Kun; Cui, Xinyang; Fu, Wenyu; Qiao, Aike

    2018-04-01

    The current finite element analysis of vascular stent expansion does not take into account the effect of the stent release pose on the expansion results. In this study, stent and vessel model were established by Pro/E. Five kinds of finite element assembly models were constructed by ABAQUS, including 0 degree without eccentricity model, 3 degree without eccentricity model, 5 degree without eccentricity model, 0 degree axial eccentricity model and 0 degree radial eccentricity model. These models were divided into two groups of experiments for numerical simulation with respect to angle and eccentricity. The mechanical parameters such as foreshortening rate, radial recoil rate and dog boning rate were calculated. The influence of angle and eccentricity on the numerical simulation was obtained by comparative analysis. Calculation results showed that the residual stenosis rates were 38.3%, 38.4%, 38.4%, 35.7% and 38.2% respectively for the 5 models. The results indicate that the pose has less effect on the numerical simulation results so that it can be neglected when the accuracy of the result is not highly required, and the basic model as 0 degree without eccentricity model is feasible for numerical simulation.

  3. In vitro experiments of vessel wall apposition between the Enterprise and Enterprise 2 stents for treatment of cerebral aneurysms.

    PubMed

    Kono, Kenichi; Terada, Tomoaki

    2016-02-01

    A closed-cell stent called Enterprise has been used for stent-assisted coil embolization of cerebral aneurysms. The Enterprise stent tends to cause kinks and vessel wall malposition in curved vessels and may cause thromboembolic complications. We evaluated vessel wall apposition of a new closed-cell stent, Enterprise 2, compared with a previous Enterprise stent, using curved vascular silicone models. The Enterprise or Enterprise 2 stent was deployed in curved vascular models with various radii of approximately 5 to 10 mm. Stent deployment was performed 25 times in each stent. A push-pull technique was used to minimize incomplete wall apposition. To evaluate conformity of stents, gaps between a stent and a vessel wall were measured. The gap ratio (gap / a wall diameter) was 15 % ± 17 % (mean ± standard deviation) and 41 % ± 15 % with the Enterprise 2 stent and the Enterprise stent, respectively. Taking gap ratios and radii of vessel curvature into consideration, the Enterprise 2 stent had significantly better wall apposition than the Enterprise stent (p = 0.005). In the same radius of vessel curvature, the Enterprise 2 stent had approximately half of the gap compared with the Enterprise stent. There were no significant differences in vessel straightening effects between the two stents. The Enterprise 2 stent has better wall apposition in curved vessels than the Enterprise stent. The gap between a vessel wall and the Enterprise 2 stent is approximately half that of the Enterprise stent. However, gaps and kinks are still present in curved vessels with a small radius. Caution should be taken for kinks and malposition in acutely curved vessels, such as the siphon of the internal carotid artery.

  4. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilhelm, K.E., E-mail: wilhelm@uni-bonn.de; Grabolle, B.; Urbach, H.

    2006-10-15

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted withoutmore » major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency.« less

  5. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    PubMed

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  6. Clinical verification of a theory for predicting side branch stenosis after main vessel stenting in coronary bifurcation lesions.

    PubMed

    Vassilev, Dobrin; Gil, Robert

    2008-12-01

    To verify in a clinical scenario a theory for predicting side branch (SB) stenosis after main vessel stent implantation in coronary bifurcation lesions. Many unresolved issues remain regarding SB compromise when the parent vessel is stented. Bifurcation lesions (all Medina types) were subjected to angiographic analysis to determine the angle, defined as alpha, between the axes of the parent vessel and the SB. Using the prediction that the percent diameter stenosis (%DS) is equal to the cosine of angle alpha and relating it to a formula to determine the minimal lumen diameter (MLD) led to the following equation: MLD = ds x (1 -cos alpha); ds refers to the diameter of the SB. The predicted and observed SB stenosis values following angiography were compared. Fifty-two patients with 57 lesions were included in the analysis. Patient demographics and characteristics were similar to those in previous studies. There was a high coefficient of determination between the predicted and observed values of %DS (r(2)= 0.82, P < 0.001) and MLD (r(2)= 0.86, P < 0.001). We determined a cutoff value of 70% for predicted %DS for SB closure. When using multivariate regression analysis, the only predictor of SB ostial stenosis after stenting was alpha angle, whereas the predictors of MLD included the angle alpha and the RVD of the SB. Our analysis shows that the most powerful independent predictor of SB compromise is a new variable angle alpha.

  7. Re-use of pilot data and interim analysis of pivotal data in MRMC studies: a simulation study

    NASA Astrophysics Data System (ADS)

    Chen, Weijie; Samuelson, Frank; Sahiner, Berkman; Petrick, Nicholas

    2017-03-01

    Novel medical imaging devices are often evaluated with multi-reader multi-case (MRMC) studies in which radiologists read images of patient cases for a specified clinical task (e.g., cancer detection). A pilot study is often used to measure the effect size and variance parameters that are necessary for sizing a pivotal study (including sizing readers, non-diseased and diseased cases). Due to the practical difficulty of collecting patient cases or recruiting clinical readers, some investigators attempt to include the pilot data as part of their pivotal study. In other situations, some investigators attempt to perform an interim analysis of their pivotal study data based upon which the sample sizes may be re-estimated. Re-use of the pilot data or interim analyses of the pivotal data may inflate the type I error of the pivotal study. In this work, we use the Roe and Metz model to simulate MRMC data under the null hypothesis (i.e., two devices have equal diagnostic performance) and investigate the type I error rate for several practical designs involving re-use of pilot data or interim analysis of pivotal data. Our preliminary simulation results indicate that, under the simulation conditions we investigated, the inflation of type I error is none or only marginal for some design strategies (e.g., re-use of patient data without re-using readers, and size re-estimation without using the effect-size estimated in the interim analysis). Upon further verifications, these are potentially useful design methods in that they may help make a study less burdensome and have a better chance to succeed without substantial loss of the statistical rigor.

  8. Correction of Stent Distortion and Overhanging Stent Struts during Left Main Bifurcation Stenting by Selective Distal Stent Cell Re-Wiring: A Novel Guidewire Approach

    PubMed Central

    Sabbah, Mahmoud; Kadota, Kazushige; Fuku, Yasushi; Mitsudo, Kazuaki

    2015-01-01

    Stent malapposition and overhanging stent struts in front of the side branch (SB) ostium are not uncommon following bifurcation stenting that might lead to stent thrombosis. We herein present 2 cases, in which optical frequency domain imaging and intravascular ultrasound effectively revealed stent malapposition and overhanging struts inside the ostium of the SB following left main coronary artery stenting. Therefore, we introduced a novel technique for rectification of these incidental findings by selective SB re-wiring through the most distal stent cell with the adjunctive help of a double lumen microcatheter. PMID:27122906

  9. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    PubMed Central

    Kwon, Chang-Il; Lehman, Glen A.

    2016-01-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  10. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    PubMed

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  11. Conditional power and predictive power based on right censored data with supplementary auxiliary information.

    PubMed

    Sun, Libo; Wan, Ying

    2018-04-22

    Conditional power and predictive power provide estimates of the probability of success at the end of the trial based on the information from the interim analysis. The observed value of the time to event endpoint at the interim analysis could be biased for the true treatment effect due to early censoring, leading to a biased estimate of conditional power and predictive power. In such cases, the estimates and inference for this right censored primary endpoint are enhanced by incorporating a fully observed auxiliary variable. We assume a bivariate normal distribution of the transformed primary variable and a correlated auxiliary variable. Simulation studies are conducted that not only shows enhanced conditional power and predictive power but also can provide the framework for a more efficient futility interim analysis in terms of an improved accuracy in estimator, a smaller inflation in type II error and an optimal timing for such analysis. We also illustrated the new approach by a real clinical trial example. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Peri-strut low-intensity areas in optical coherence tomography correlate with peri-strut inflammation and neointimal proliferation: an in-vivo correlation study in the familial hypercholesterolemic coronary swine model of in-stent restenosis.

    PubMed

    Tellez, Armando; Afari, Maxwell E; Buszman, Piotr P; Seifert, Paul; Cheng, Yanping; Milewski, Krzysztof; McGregor, Jennifer C; Garza, Javier A; Roberts, Mary B; Yi, Geng Hua; Kaluza, Greg L; Granada, Juan F

    2014-11-01

    Peri-strut low-intensity area (PLI) is a common imaging finding during the evaluation of in-stent neointima using optical coherence tomography (OCT). We aimed to determine the biological significance of PLI by comparing in-vivo OCT images with the corresponding histological sections obtained from the familial hypercholesterolemic swine model of coronary stenosis. A total of 26 coronary vessels of nine familial hypercholesterolemic swine were injured with 30% balloon overstretch and then immediately followed by everolimus eluting or bare metal stent placement at 20% overstretch. At 30 days, all stented vessels were subjected to in-vivo OCT analysis and were harvested for histological evaluation. For OCT analysis, stent cross-sections (three per stent) were categorized into presence (PLI+) or absence (PLI-) of PLI. In histology, inflammation and fibrin deposition were scored semiquantitatively from 0 (none) to 3 (severe). PLI was found in 64.9% of stent sections. Peri-strut inflammation was more frequently observed in OCT sections PLI (+) compared with PLI (-) (56.0 vs. 7.4%, P=0.01). In contrast, peri-strut fibrin deposits was similar in both groups (PLI+=58.0% vs. PLI-=59.3%, P=0.94). Histological neointimal thickness was significantly higher in PLI (+) sections (mean±SE: 0.68±0.06 vs. 0.34±0.02 mm; P<0.01), yielding a higher percent area stenosis compared with PLI (-) (mean±SE: 59.0±4.4 vs. 34.1±2.2%, P<0.01). The PLI diagnostic sensitivity and specificity for inflammation were 80 and 76.1%, respectively (>56% PLI, area under the curve=0.86, P<0.01), whereas for fibrin deposition, the sensitivity and specificity were 42.2 and 76.1%, respectively (area under the curve=0.56, P=NS). Area under the receiver operating characteristic curve was significantly higher for identifying inflammation than fibrin (0.86 vs. 0.56, P<0.01). The severity of PLI correlated with the neointimal thickness when assessed by OCT (R=0.79, P<0.001). The presence of PLI in OCT correlates with neointimal thickness and appears to have a diagnostic value in the recognition of peri-strut inflammation, therefore possibly serving as a surrogate for in-vivo assessment of stent efficacy.

  13. Comparative Computed Flow Dynamic Analysis of Different Optimization Techniques in Left Main Either Provisional or Culotte Stenting

    PubMed Central

    Dell’Avvocata, Fabio; Zuin, Marco; Giatti, Sara; Duong, Khanh; Pham, Trung; Tuan, Nguyen Si; Vassiliev, Dobrin; Daggubati, Ramesh; Nguyen, Thach

    2017-01-01

    Abstract Background and Objectives Provisional and culotte are the most commonly used techniques in left main (LM) stenting. The impact of different post-dilation techniques on fluid dynamic of LM bifurcation has not been yet investigated. The aim of this study is to evaluate, by means of computational fluid dynamic analysis (CFD), the impact of different post-dilation techniques including proximal optimization technique (POT), kissing balloon (KB), POT-Side-POT and POT–KB-POT, 2-steps Kissing (2SK) and Snuggle Kissing balloon (SKB) on flow dynamic profile after LM provisional or culotte stenting. Methods We considered an LM-LCA-LCX bifurcation reconstructed after reviewing 100 consecutive patients (mean age 71.4 ± 9.3 years, 49 males) with LM distal disease. The diameters of LAD and LCX were modelled according to the Finnet’s law as following: LM 4.5 mm, LAD 3.5 mm, LCX 2.75 mm, with bifurcation angle set up at 55°. Xience third-generation stent (Abbot Inc., USA) was reconstructed and virtually implanted in provisional/cross-over and culotte fashion. POT, KB, POT-side-POT, POT-KB-POT, 2SK and SKB were virtually applied and analyzed in terms of the wall shear stress (WSS). Results Analyzing the provisional stenting, the 2SK and KB techniques had a statistically significant lower impact on the WSS at the carina, while POT seemed to obtain a neutral effect. In the wall opposite to the carina, the more physiological profile has been obtained by KB and POT with higher WSS value and smaller surface area of the lower WSS. In culotte stenting, at the carina, POT-KB-POT and 2SK had a very physiological profile; while at the wall opposite to the carina, 2SK and POT–KB-POT decreased significantly the surface area of the lower WSS compared to the other techniques. Conclusion From the fluid dynamic point of view in LM provisional stenting, POT, 2SK and KB showed a similar beneficial impact on the bifurcation rheology, while in LM culotte stenting, POT-KB-POT and 2SK performed slightly better than the other techniques, probably reflecting a better strut apposition. PMID:29340277

  14. Endoscopic management of malignant biliary obstruction by means of covered metallic stents: primary stent placement vs. re-intervention.

    PubMed

    Kida, M; Miyazawa, S; Iwai, T; Ikeda, H; Takezawa, M; Kikuchi, H; Watanabe, M; Imaizumi, H; Koizumi, W

    2011-12-01

    Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Occlusion of covered metallic stents now occurs in about half of all patients with malignant biliary strictures. The removal of metallic stents followed by placement of a second stent has been attempted, but outcomes remain controversial. The aim of the current study was to evaluate the effectiveness and safety of the primary placement and secondary placement (re-intervention) of covered metallic stents and to assess the feasibility and safety of stent removal. The study included 186 patients with unresectable malignant biliary strictures who underwent primary stent placement between October 2001 and March 2010.  Covered biliary self-expandable metal stents (SEMSs) were removed in 39 of these patients, and 36 underwent re-intervention. The patency times, occlusion rates of the first stent and re-intervention, success rates of stent removal, and complications were investigated. Covered SEMSs were placed in 186 patients. The median patency time of the first stent was 352 days. Stent occlusion occurred in 48.9 % of the patients and was mainly caused by debris or food residue (37 %), dislocation (19 %), and migration with hyperplasia (19 %). Stent removal was attempted in 50 patients and was successful without complication in 39 (78 %). Most of the patients in whom stent removal was unsuccessful had migration with hyperplasia. The median patency time of the second stent was 263 days. The stent patency time did not significantly differ between the first and the second stent. Covered SEMSs could be safely removed at the time of stent occlusion. Patency rates were similar for initial stent placement and re-intervention. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Comparison of Flow Characteristics of Novel Three-Dimensional Printed Ureteral Stents Versus Standard Ureteral Stents in a Porcine Model.

    PubMed

    Del Junco, Michael; Yoon, Renai; Okhunov, Zhamshid; Abedi, Garen; Hwang, Christina; Dolan, Benjamin; Landman, Jaime

    2015-09-01

    We compared the flow characteristics of novel three-dimensional (3D) printed ureteral stents with four conventional double-pigtail stents in an ex vivo porcine model. In six ex vivo porcine urinary systems with kidneys and ureters intact, we deployed a 5F occlusion catheter in an interpolar calix. We tested each system with antegrade irrigation with a 0.9% saline bag placed 35 cm above the renal pelvis. We evaluated four standard stents (6F Universa® Soft, 7F Percuflex,™ 7/10F Applied Endopyelotomy, 8.5F Filiform Double Pigtail) and compared them with a 9F 3D printed prototype stent. For each stent, we measured the total, extraluminal, and intraluminal flow rates. The mean total flow rates for 3D printed stents were significantly higher than the 6F, 7F, and 7/10F stents (P<0.05). No significant difference was seen in the total flow rate for the 3D printed stent and the 8.5F stent. The mean extraluminal flow rates for the 3D stents were similar to those of 7F stents, but significantly lower than 6F stents (P<0.001) and 8.5F stents (P<0.05) and higher than 7/10F stents (P<0.001). The mean intraluminal flow rates for the 3D printed stents were significantly higher than the 6F, 7F, 7/10F, and 8.5F stents (P<0.05). In this pilot study, 3D printed stents manifested a mean total flow rate comparable to the flow rates of contemporary stents. Continued advances in technology and material may permit functionally feasible 3D printed ureteral stents.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Grenacher, L.; Stampfl, U.

    The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 {mu}m). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury,more » vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 {mu}m. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 {mu}m and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.« less

  17. Silver-nanoparticle-coated biliary stent inhibits bacterial adhesion in bacterial cholangitis in swine.

    PubMed

    Wen, Wei; Ma, Li-Mei; He, Wei; Tang, Xiao-Wei; Zhang, Yin; Wang, Xiang; Liu, Li; Fan, Zhi-Ning

    2016-02-01

    One of the major limitations of biliary stents is the stent occlusion, which is closely related to the over-growth of bacteria. This study aimed to evaluate the feasibility of a novel silver-nanoparticle-coated polyurethane (Ag/PU) stent in bacterial cholangitis model in swine. Ag/PU was designed by coating silver nanoparticles on polyurethane (PU) stent. Twenty-four healthy pigs with bacterial cholangitis using Ag/PU and PU stents were randomly divided into an Ag/PU stent group (n=12) and a PU stent group (n=12), respectively. The stents were inserted by standard endoscopic retrograde cholangiopancreatography. Laboratory assay was performed for white blood cell (WBC) count, alanine aminotransferase (ALT), interleukin-1beta (IL-1beta), tumor necrosis factor-alpha (TNF-alpha) at baseline time, 8 hours, 1, 2, 3, and 7 days after stent placements. The segment of bile duct containing the stent was examined histologically ex vivo. Implanted biliary stents were examined by a scan electron microscope. The amount of silver release was also measured in vitro. The number of inflammatory cells and level of ALT, IL-1beta and TNF-alpha were significantly lower in the Ag/PU stent group than in the PU stent group. Hyperplasia of the mucosa was more severe in the PU stent group than in the Ag/PU stent group. In contrast to the biofilm of bacteria on the PU stent, fewer bacteria adhered to the Ag/PU stent. PU biliary stents modified with silver nanoparticles are able to alleviate the inflammation of pigs with bacterial cholangitis. Silver-nanoparticle-coated stents are resistant to bacterial adhesion.

  18. Carotid artery stents on CT angiography: in vitro comparison of different stent designs and sizes using 16-, 64- and 320-row CT scanners.

    PubMed

    Lettau, Michael; Kotter, Elmar; Bendszus, Martin; Hähnel, Stefan

    2014-10-01

    CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  19. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    PubMed

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  20. Meta-analysis and meta-regression analysis of outcomes of carotid endarterectomy and stenting in the elderly.

    PubMed

    Antoniou, George A; Georgiadis, George S; Georgakarakos, Efstratios I; Antoniou, Stavros A; Bessias, Nikos; Smyth, John Vincent; Murray, David; Lazarides, Miltos K

    2013-12-01

    Uncertainty exists about the influence of advanced age on the outcomes of carotid revascularization. To undertake a comprehensive review of the literature and conduct an analysis of the outcomes of carotid interventions in the elderly. A systematic literature review was conducted to identify articles comparing early outcomes of carotid endarterectomy (CEA) or carotid stenting (CAS) in elderly and young patients. Combined overall effect sizes were calculated using fixed or random effects models. Meta-regression models were formed to explore potential heterogeneity as a result of changes in practice over time. RESULTS Our analysis comprised 44 studies reporting data on 512,685 CEA and 75,201 CAS procedures. Carotid stenting was associated with increased incidence of stroke in elderly patients compared with their young counterparts (odds ratio [OR], 1.56; 95% CI, 1.40-1.75), whereas CEA had equivalent cerebrovascular outcomes in old and young age groups (OR, 0.94; 95% CI, 0.88-0.99). Carotid stenting had similar peri-interventional mortality risks in old and young patients (OR, 0.86; 95% CI, 0.72-1.03), whereas CEA was associated with heightened mortality in elderly patients (OR, 1.62; 95% CI, 1.47-1.77). The incidence of myocardial infarction was increased in patients of advanced age in both CEA and CAS (OR, 1.64; 95% CI, 1.57-1.72 and OR, 1.30; 95% CI, 1.16-1.45, respectively). Meta-regression analyses revealed a significant effect of publication date on peri-interventional stroke (P = .003) and mortality (P < .001) in CAS. Age should be considered when planning a carotid intervention. Carotid stenting has an increased risk of adverse cerebrovascular events in elderly patients but mortality equivalent to younger patients. Carotid endarterectomy is associated with similar neurologic outcomes in elderly and young patients, at the expense of increased mortality.

  1. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    PubMed

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p < 0.05) at 12 months. This randomized trial in symptomatic patients with peripheral arterial disease who underwent endovascular treatment for long femoropopliteal lesions demonstrated significant clinical and patency benefits for heparin-bonded covered stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare nitinol stent in the treatment of TASC B, C and D lesions in superficial femoral artery occlusive disease; ISRCTN48164244). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    PubMed

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P < 0.01). The radial force of the thoracic stents was greater than that of all three endovascular stents (P < 0.01). Differences in radial force depend on types of stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  3. Stent selection for both biliary and pancreatic strictures caused by chronic pancreatitis: multiple plastic stents or metallic stents?

    PubMed

    Gupta, Rajesh; Reddy, D Nageshwar

    2011-09-01

    Endoscopic stenting is an effective treatment option in the management of both benign biliary strictures and pancreatic ductal strictures. Plastic stents and self-expandable metal stents have been used with variable success for the management of both benign biliary strictures and pancreatic ductal strictures caused by chronic pancreatitis. Fully covered self-expandable metal stents of improved design represent a major technological advance which has added to the endoscopic armamentarium. Both multiple plastic stents and covered self-expandable metal stents have shown promising results. However, data to support the use of self-expandable metal stents over multiple plastic stents or vice versa are still lacking.

  4. Biodegradable stent or balloon dilatation for benign oesophageal stricture: pilot randomised controlled trial.

    PubMed

    Dhar, Anjan; Close, Helen; Viswanath, Yirupaiahgari K; Rees, Colin J; Hancock, Helen C; Dwarakanath, A Deepak; Maier, Rebecca H; Wilson, Douglas; Mason, James M

    2014-12-28

    To undertake a randomised pilot study comparing biodegradable stents and endoscopic dilatation in patients with strictures. This British multi-site study recruited seventeen symptomatic adult patients with refractory strictures. Patients were randomised using a multicentre, blinded assessor design, comparing a biodegradable stent (BS) with endoscopic dilatation (ED). The primary endpoint was the average dysphagia score during the first 6 mo. Secondary endpoints included repeat endoscopic procedures, quality of life, and adverse events. Secondary analysis included follow-up to 12 mo. Sensitivity analyses explored alternative estimation methods for dysphagia and multiple imputation of missing values. Nonparametric tests were used. Although both groups improved, the average dysphagia scores for patients receiving stents were higher after 6 mo: BS-ED 1.17 (95%CI: 0.63-1.78) P = 0.029. The finding was robust under different estimation methods. Use of additional endoscopic procedures and quality of life (QALY) estimates were similar for BS and ED patients at 6 and 12 mo. Concomitant use of gastrointestinal prescribed medication was greater in the stent group (BS 5.1, ED 2.0 prescriptions; P < 0.001), as were related adverse events (BS 1.4, ED 0.0 events; P = 0.024). Groups were comparable at baseline and findings were statistically significant but numbers were small due to under-recruitment. The oesophageal tract has somatic sensitivity and the process of the stent dissolving, possibly unevenly, might promote discomfort or reflux. Stenting was associated with greater dysphagia, co-medication and adverse events. Rigorously conducted and adequately powered trials are needed before widespread adoption of this technology.

  5. Effects of specific alpha-1A/1D blocker on lower urinary tract symptoms due to double-J stent: a prospectively randomized study.

    PubMed

    Wang, Chung-Jing; Huang, Shi-Wei; Chang, Chien-Hsing

    2009-06-01

    The aim of our study was to evaluate the effect of tamsulosin in improving symptoms in patients with indwelling double-J ureteral stents. This prospective study lasted from April 2006 to March 2008. All the patients with symptomatic lower ureteral stones with <15 mm diameter were enrolled, and were prospectively randomized (random numbers table) into two groups. A total of 154 patients, with insertion of a double-J ureteral stent after ureteroscopic stone removal. In group 1, 75 patients were enrolled and received placebo for 2 weeks. Group 2 included 79 patients who received 0.4 mg of tamsulosin, once daily for 2 weeks. All patients completed the validated ureteral stent symptom questionnaire (USSQ) and quality of life of international prostate symptom scale (IPSS) for evaluating the symptoms of double-J stents and quality of life after double-J stent insertion and removal, respectively. The analysis of the questionnaire at W1 revealed a significant difference in the main score index of urinary symptoms, body pain and general health between groups 1 and 2. When comparing W1 evaluation with that of W4 after double-J removal, both groups showed significant worsening of urinary symptoms, body pain, general health and work performance, except sexual performance. The mean score of quality of life in IPSS was 4.21 in group 1 and 1.6 in group 2. Tamsulosin can improve a subset of stent-related urinary symptoms and quality of life effectively and may be applied in routine clinical practice.

  6. Cross-cultural application of the Korean version of Ureteral Stent Symptoms Questionnaire.

    PubMed

    Park, Jinsung; Shin, Dong Wook; You, Changhee; Chung, Kyung Jin; Han, Deok Hyun; Joshi, Hrishi B; Park, Hyung Keun

    2012-11-01

    We validated the Korean version of the Ureteral Stent Symptoms Questionnaire (USSQ) in patients with an indwelling ureteral stent. Linguistic validation of the original USSQ was performed through a standard process including translation, back translation, and pilot study. A total of 65 patients who underwent ureteroscopic surgery were asked to complete the Korean USSQ as well as EuroQOL (male and female), the International Prostate Symptom Score (male), and Urogenital Distress Inventory-6 (female). Patients were evaluated at weeks 1 and 2 after stent placement and at week 4 after removal. Sixty-four healthy subjects without a ureteral stent were also asked to complete the Korean USSQ once. The psychometric properties of the questionnaire were analyzed. Internal consistencies (Cronbach α coefficients: 0.73-0.83) and test-retest reliability (Spearman correlation coefficient: ≥0.6) were satisfactory for urinary symptom, body pain, general health, and work performance domains. Most USSQ domains showed moderate correlations with each other. Convergent validity determined by correlation between other instruments and corresponding USSQ domain was satisfactory. Sensitivity to change and discriminant validity were also good in most domains (P<0.01). Only a small proportion of the study population had an active sexual life, with the stent in situ, limiting its analysis. The Korean version of the USSQ is a reliable and valid instrument that can be self-administered by Korean patients with a ureteral stent in the clinical and research settings. Further clinical studies in the Korean settings would be useful to provide robust data on sensitivity to change.

  7. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    PubMed

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  8. Comparison of the 9-month intra-stent conditions and 2-year clinical outcomes after Resolute zotarolimus-eluting stent implantation between 3-month and standard dual antiplatelet therapy.

    PubMed

    Fujimoto, Wataru; Sawada, Takahiro; Toba, Takayoshi; Takahashi, Yu; Miyata, Taishi; Oishi, Shogo; Osue, Tsuyoshi; Onishi, Tetsuari; Takaya, Tomofumi; Shimane, Akira; Taniguchi, Yasuyo; Kawai, Hiroya; Yasaka, Yoshinori

    2018-07-01

    The use of short-duration dual antiplatelet therapy (DAPT) remains controversial. To investigate efficacy and safety of short-duration DAPT, we performed a detailed comparison of intra-stent conditions by optical coherence tomography (OCT) after second-generation drug-eluting stent implantation with short-term and standard DAPT. Eighty-two consecutive patients with stable angina pectoris who received Resolute zotarolimus-eluting stents (R-ZESs; Medtronic Cardiovascular, Santa Rosa, CA, USA) were enrolled. Patients were assigned to 3-month (3M group: 41 patients) and standard (standard group: 41 patients) DAPT. In the 3M group, clopidogrel was discontinued 3 months after stent implantation. In the standard group, DAPT was maintained until follow-up OCT. At 9 months, neointimal proliferation was significantly larger in the 3M group, but there were no significant between-group differences in the proportion of uncovered and malapposed strut. The prevalence of abnormal intra-stent tissue (AIT) at 9 months was equivalent between groups. A multiple regression analysis revealed malapposition at 9 months as the strongest independent predictor of AIT at 9 months, and the prevalence of AIT was not associated with DAPT duration. Over 2 years, cardiac events were equal between groups; however, major bleeding was higher tendency in the standard group than in the 3M group. This OCT study indicated that reducing DAPT's duration may provide acceptable arterial healing in patients with implanted R-ZESs. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Intralacrimal migration of Masterka® stents.

    PubMed

    Fayet, B; Racy, E; Katowitz, W R; Katowitz, J A; Ruban, J-M; Brémond-Gignac, D

    2018-03-01

    Tearing and conjunctivitis in children are commonly due to lacrimal drainage system obstruction. Congenital nasolacrimal obstruction is a common pathology treated by probing with or without silicone stent insertion, depending upon the age of the child. The silicone stent is self-retaining and placed for at least one month. Masterka ® is a recent version of Monoka ® , which may lead to the same surgical complications, such as intralacrimal migration. The medical records of two patients surgically treated with the Masterka ® probe for nasolacrimal duct obstruction, who developed intralacrimal migration of the stent, were retrospectively reviewed and analyzed. A 41-month-old child and an 18-month-old child presented with disappearance of the silicone tube after 7 days and 2 years respectively. In the first case, the tube migrated completely within the lacrimal system and became externalized through the nose at 2 years, while in the second case, the Masterka ® was retrieved through a canalicular approach. In both cases, infants had no further tearing. The frequency self-retaining stent disappearance is estimated at 15%. Among these cases, intralacrimal migration is only reported in 0.5% of cases. To prevent intralacrimal migration, the surgical technique must follow a certain number of rules. Management, based on residual epiphora, is discussed. Prevention of intralacrimal migration of self-retaining stents involves a rigorous analysis of the relationship between the meatus and the fixation head at the time of placement. After lacrimal intubation, scheduled monitoring is necessary to screen for stent disappearance. Management is based on clinical findings, anterior rhinoscopy and even exploratory canaliculotomy. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  10. Inhibition of plaque neovascularization and intimal hyperplasia by specific targeting vascular endothelial growth factor with bevacizumab-eluting stent: an experimental study.

    PubMed

    Stefanadis, Christodoulos; Toutouzas, Konstantinos; Stefanadi, Elli; Lazaris, Andreas; Patsouris, Efstratios; Kipshidze, Nicholas

    2007-12-01

    Neovascularization is associated with destabilization of atheromatic plaques. Increased expression of vascular endothelial growth factor (VEGF) is important in the process of neovascularization. We assessed the effect of bevacizumab, a monoclonal antibody specific for VEGF, on neovascularization. We used 12 New Zealand rabbits under atherogenic diet for 3 weeks. We immersed a phosphorycholine coated stent into a solution of 4 ml bevacizumab according to previous studies. Twelve eluting stents and 12 non-eluting stents were implanted in the middle segment of the rabbit's iliac arteries. Follow-up angiography was performed at 4 weeks and tissues were obtained for histological analysis. The procedure of stent loading with bevacizumab and stent implantation was successful. There was no difference in angiographic measurements before, after implantation and at follow-up between the two groups. mean neointimal thickness (0.09+/-0.02 versus 0.12+/-0.02 mm, p<0.01), and mean neointimal area (1.08+/-0.09 versus 1.20+/-0.12 mm(2), p<0.01) were less in the bevacizumab treated segments. bevacizumab-treated arterial segments demonstrated significantly decreased microvessel density compared with the control group (1.69+/-0.06 CI: 1.65-1.73 versus 15.68+/-0.56 CI: 15.32-16.04 vessels per mm(2), p<0.001) and vegf expression was decreased in the media and adventitia of bevacizumab group. Endothelialization, inflammation and injury scores were similar between the two groups. These results suggest that bevacizumab-eluting stent implantation in rabbit iliac arteries is safe, and inhibits neovascularization without affecting the endothelialization.

  11. Biodegradable stent or balloon dilatation for benign oesophageal stricture: Pilot randomised controlled trial

    PubMed Central

    Dhar, Anjan; Close, Helen; Viswanath, Yirupaiahgari K; Rees, Colin J; Hancock, Helen C; Dwarakanath, A Deepak; Maier, Rebecca H; Wilson, Douglas; Mason, James M

    2014-01-01

    AIM: To undertake a randomised pilot study comparing biodegradable stents and endoscopic dilatation in patients with strictures. METHODS: This British multi-site study recruited seventeen symptomatic adult patients with refractory strictures. Patients were randomised using a multicentre, blinded assessor design, comparing a biodegradable stent (BS) with endoscopic dilatation (ED). The primary endpoint was the average dysphagia score during the first 6 mo. Secondary endpoints included repeat endoscopic procedures, quality of life, and adverse events. Secondary analysis included follow-up to 12 mo. Sensitivity analyses explored alternative estimation methods for dysphagia and multiple imputation of missing values. Nonparametric tests were used. RESULTS: Although both groups improved, the average dysphagia scores for patients receiving stents were higher after 6 mo: BS-ED 1.17 (95%CI: 0.63-1.78) P = 0.029. The finding was robust under different estimation methods. Use of additional endoscopic procedures and quality of life (QALY) estimates were similar for BS and ED patients at 6 and 12 mo. Concomitant use of gastrointestinal prescribed medication was greater in the stent group (BS 5.1, ED 2.0 prescriptions; P < 0.001), as were related adverse events (BS 1.4, ED 0.0 events; P = 0.024). Groups were comparable at baseline and findings were statistically significant but numbers were small due to under-recruitment. The oesophageal tract has somatic sensitivity and the process of the stent dissolving, possibly unevenly, might promote discomfort or reflux. CONCLUSION: Stenting was associated with greater dysphagia, co-medication and adverse events. Rigorously conducted and adequately powered trials are needed before widespread adoption of this technology. PMID:25561787

  12. The carina angle-new geometrical parameter associated with periprocedural side branch compromise and the long-term results in coronary bifurcation lesions with main vessel stenting only.

    PubMed

    Gil, Robert J; Vassilev, Dobrin; Formuszewicz, Radoslaw; Rusicka-Piekarz, Teresa; Doganov, Alexander

    2009-12-01

    The two main problems unresolved in coronary bifurcation stenting are periprocedural side branch compromise and higher restenosis at long term. The purpose of this study is to reveal the link between periprocedural side branch compromise and long-term results after main vessel stenting only in coronary bifurcations. Eighty-four patients formed the study population. The inclusion criteria were good-quality angiograms, with maximal between-branch angle opening, no overlap, permitting accurate angiographic analysis. Carina angle (alpha)-the distal angle between main vessel (MV) before bifurcation and side branch (SB)-was measured pre- and poststenting. Clinical follow-up 9-12 months was obtained with coronary angiography if needed. The patient population was high-risk with 33% diabetics and 84% two- and three-vessel disease. Ninety-five stents were implanted in 92 lesions, with three T-stenting cases. Drug-eluting stents were implanted in 54%. Kissing-balloon (KBI) or sequential inflation was performed in 35%. SB functional closure occurred in 17.4%, with independent predictors alpha < 40 degrees and diameter ratio MB/SB >1.22. After 12+/-4 months there were five myocardial infarctions (6%) and 13 (15%) target lesion revascularization procedures. Independent predictors of major cardiovascular events were carina angle <40 degrees , MB lesion length >8 mm, negative change of between-branch angle, DES usage, and KBI. Smaller carina angle with straightening of MV-main branch from stent implantation in coronary bifurcations predicted higher SB compromise, restenosis, and MACE rates during follow-up of 1 year.

  13. The use of JJ stent in the management of deep endometriosis lesion, affecting or potentially affecting the ureter: a review of our practice.

    PubMed

    Weingertner, A S; Rodriguez, B; Ziane, A; Gibon, E; Thoma, V; Osario, F; Haddad, C; Wattiez, A

    2008-08-01

    With the increasing number of operative laparoscopies performed for the treatment of deep pelvic endometriosis, technical difficulties and risk of complications inevitably increase. We report our experience using JJ stents, in women treated for deep pelvic endometriosis, with regard to prevention and management of ureteral lesions. Descriptive retrospective analysis between March 2004 and March 2007. Department of Obstetrics and Gynaecology, University Hospital, Strasbourg, France. Cases of women who underwent laparoscopic surgery for severe endometriosis and who needed a JJ stent in their management were recorded. Laparoscopic surgery was performed at the Department of Obstetrics and Gynaecology at CMCO-SIHCUS and Hautepierre Hospitals, Strasbourg, which are referral centres in the treatment of deep endometriosis. To evaluate the contribution of JJ stent in the prevention and management of ureteral lesions from endometriotic origin and/or iatrogenic origin in women treated for deep pelvic endometriosis. A total of 145 women had surgery for deep pelvic endometriosis. Seventeen (11.7%) women had a JJ ureteral stent inserted. In 82.4% of women, the stent was inserted pre- or peroperatively. We noted three ureteral complications, of which only one needed management by laparotomy. Except in extreme cases, management of ureteral endometriosis should be performed laparoscopically. Ureteral lesions whether iatrogenic, or secondary to endometriotic disease, can be treated by cystoscopy, JJ stent and laparoscopy. The combination of these three elements is the optimal management and is unlikely to cause subsequent complications. Laparotomy and its associated morbidity should be avoided.

  14. Prediction of advanced endovascular stent graft rotation and its associated morbidity and mortality.

    PubMed

    Crawford, Sean A; Sanford, Ryan M; Doyle, Matthew G; Wheatcroft, Mark; Amon, Cristina H; Forbes, Thomas L

    2018-01-29

    Advanced endovascular aneurysm repair (EVAR) with fenestrated and branched stent grafts is increasingly being used to repair complex aortic aneurysms; however, these devices can rotate unpredictably during deployment, leading to device misalignment. The objectives of this study were to quantify the short-term clinical outcomes in patients with intraoperative stent graft rotation and to identify quantitative anatomic markers of the arterial geometry that can predict stent graft rotation preoperatively. A prospective study evaluating all patients undergoing advanced EVAR was conducted at two university-affiliated hospitals between November 2015 and December 2016. Stent graft rotation (defined as ≥10 degrees) was measured on intraoperative fluoroscopic video of the deployment sequence. Standard preoperative computed tomography angiography imaging was used to calculate the geometric properties of the arterial anatomy. Any in-hospital and 30-day complications were prospectively documented, and a composite outcome of any end-organ ischemia or death was used as the primary end point. Thirty-nine patients undergoing advanced EVAR were enrolled in the study with a mean age of 75 years (interquartile range [IQR], 71-80 years) and a mean aneurysm diameter of 64 mm (IQR, 59-65 mm). The incidence of stent graft rotation was 37% (n = 14), with a mean rotation of 25 degrees (IQR, 21-28 degrees). A nominal logistic regression model identified iliac artery torsion, volume of iliac artery calcification, and stent graft length as the primary predictive factors. The total net torsion and the total volume of calcific plaque were higher in patients with stent graft rotation, 8.9 ± 0.8 mm -1 vs 4.1 ± 0.5 mm -1 (P < .0001) and 1054 ± 144 mm 3 vs 525 ± 83 mm 3 (P < .01), respectively. The length of the implanted stent grafts was also higher in patients with intraoperative rotation, 172 ± 9 mm vs 156 ± 8 mm (P < .01). The composite outcome of any end-organ ischemia or death was also substantially higher in patients with stent graft rotation (36% vs 0%; P = .004). In addition, patients with stent graft rotation had significantly higher combined rates of type Ib and type III endoleaks (43% vs 8%; P = .03). Patients with intraoperative stent graft rotation have a significantly higher rate of severe postoperative complications, and this is strongly associated with higher levels of iliac artery torsion, calcification, and stent graft length. These findings suggest that preoperative quantitative analysis of iliac artery torsion and calcification may improve risk stratification of patients before advanced EVAR. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Drug eluting stents and modern stent technologies for in-stent restenosis.

    PubMed

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  16. Simulated training in colonoscopic stenting of colonic strictures: validation of a cadaver model.

    PubMed

    Iordache, F; Bucobo, J C; Devlin, D; You, K; Bergamaschi, R

    2015-07-01

    There are currently no available simulation models for training in colonoscopic stent deployment. The aim of this study was to validate a cadaver model for simulation training in colonoscopy with stent deployment for colonic strictures. This was a prospective study enrolling surgeons at a single institution. Participants performed colonoscopic stenting on a cadaver model. Their performance was assessed by two independent observers. Measurements were performed for quantitative analysis (time to identify stenosis, time for deployment, accuracy) and a weighted score was devised for assessment. The Mann-Whitney U-test and Student's t-test were used for nonparametric and parametric data, respectively. Cohen's kappa coefficient was used for reliability. Twenty participants performed a colonoscopy with deployment of a self-expandable metallic stent in two cadavers (groups A and B) with 20 strictures overall. The median time was 206 s. The model was able to differentiate between experts and novices (P = 0. 013). The results showed a good consensus estimate of reliability, with kappa = 0.571 (P < 0.0001). The cadaver model described in this study has content, construct and concurrent validity for simulation training in colonoscopic deployment of self-expandable stents for colonic strictures. Further studies are needed to evaluate the predictive validity of this model in terms of skill transfer to clinical practice. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  17. Conditional estimation using prior information in 2-stage group sequential designs assuming asymptotic normality when the trial terminated early.

    PubMed

    Shimura, Masashi; Maruo, Kazushi; Gosho, Masahiko

    2018-04-23

    Two-stage designs are widely used to determine whether a clinical trial should be terminated early. In such trials, a maximum likelihood estimate is often adopted to describe the difference in efficacy between the experimental and reference treatments; however, this method is known to display conditional bias. To reduce such bias, a conditional mean-adjusted estimator (CMAE) has been proposed, although the remaining bias may be nonnegligible when a trial is stopped for efficacy at the interim analysis. We propose a new estimator for adjusting the conditional bias of the treatment effect by extending the idea of the CMAE. This estimator is calculated by weighting the maximum likelihood estimate obtained at the interim analysis and the effect size prespecified when calculating the sample size. We evaluate the performance of the proposed estimator through analytical and simulation studies in various settings in which a trial is stopped for efficacy or futility at the interim analysis. We find that the conditional bias of the proposed estimator is smaller than that of the CMAE when the information time at the interim analysis is small. In addition, the mean-squared error of the proposed estimator is also smaller than that of the CMAE. In conclusion, we recommend the use of the proposed estimator for trials that are terminated early for efficacy or futility. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Fatigue and In Vivo Validation of a Peritoneum-Lined Self-Expanding Nitinol Stent-Graft

    PubMed Central

    Bastijanic, Jennifer M.; Etscheidt, Jordan; Sattiraju, Mallika; Bonsignore, Craig; Kopchok, George; White, Rodney; Sarac, Timur P.

    2014-01-01

    Purpose To assess the fatigue and in vivo performance of a new stent-graft incorporating bovine peritoneum lining that is designed for application in peripheral vascular occlusive disease. Methods Bovine peritoneum-lined stent-grafts were subjected to accelerated in vitro pulsatile fatigue and axial/torsional fatigue testing designed to simulate 10 years of physiological strain on the devices. At specified times the devices were evaluated for stent fracture, suture failure, or tissue tearing. Seven dogs underwent bilateral common iliac artery (CIA) balloon angioplasty injury with unilateral placement of the peritoneum-lined stent-graft. Angiography and intravascular ultrasound were performed prior to treatment, after treatment, and prior to sacrifice at 30 days. Vessels were perfusion fixed and histologically evaluated at 5 regions: above stent, proximal stent, mid stent, distal stent, and below stent. Results No evidence of stent, suture, or tissue failure was present during or after pulsatile and axial/torsional fatigue testing. At 30±0.3 days after implantation, all vessels were patent. The average lumen area at explantation across stented vessels was 25.45 mm2. Lumen areas tended to be reduced above (23.57 mm2) and below (24.17 mm2) the stent. Lumen areas were consistent across stented regions at explantation (proximal stent 27.80 mm2, mid stent 25.88 mm2, and distal stent 25.81 mm2). The mean neointimal area in peritoneum-lined stents was 2.02±1.52 mm2, with a neointima:media ratio of 1.03±0.50. These values were significantly lower in the above and below stent areas than in the stented regions, but there was no difference in either measure within the proximal, mid, or distal stent. Conclusion The custom-designed peritoneum-lined stent-graft is promising for clinical peripheral applications due to its ability to resist relevant long-term physiological stresses and outstanding short-term patency rates in canine implantations. PMID:25290804

  19. Evaluation of ERA-interim and MERRA Cloudiness in the Southern Oceans

    NASA Technical Reports Server (NTRS)

    Naud, Catherine M.; Booth, James F.; Del Genio, Anthony D.

    2014-01-01

    The Southern Ocean cloud cover modeled by the Interim ECMWF Re-Analysis (ERA-Interim) and Modern- Era Retrospective Analysis for Research and Applications (MERRA) reanalyses are compared against Moderate Resolution Imaging Spectroradiometer (MODIS) and Multiangle Imaging Spectroradiometer (MISR) observations. ERA-Interim monthly mean cloud amounts match the observations within 5%, while MERRA significantly underestimates the cloud amount. For a compositing analysis of clouds in warm season extratropical cyclones, both reanalyses show a low bias in cloud cover. They display a larger bias to the west of the cyclones in the region of subsidence behind the cold fronts. This low bias is larger for MERRA than for ERA-Interim. Both MODIS and MISR retrievals indicate that the clouds in this sector are at a low altitude, often composed of liquid, and of a broken nature. The combined CloudSat-Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) cloud profiles confirm these passive observations, but they also reveal that low-level clouds in other parts of the cyclones are also not properly represented in the reanalyses. The two reanalyses are in fairly good agreement for the dynamic and thermodynamic characteristics of the cyclones, suggesting that the cloud, convection, or boundary layer schemes are the problem instead. An examination of the lower-tropospheric stability distribution in the cyclones from both reanalyses suggests that the parameterization of shallow cumulus clouds may contribute in a large part to the problem. However, the differences in the cloud schemes and in particular in the precipitation processes, which may also contribute, cannot be excluded.

  20. Outcomes of the single-stent versus kissing-stents technique in asymmetric complex aortoiliac bifurcation lesions.

    PubMed

    Suh, Yongsung; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo

    2015-07-01

    This study investigated the outcomes of single-stent vs kissing-stents techniques in asymmetric complex aortoiliac bifurcation (ACAB) lesions. We retrospectively investigated 80 consecutive patients (69 males, 66.6 ± 8.7 years) treated with a single stent and 30 patients (26 males, 67.1 ± 7.7 years) treated with kissing stents for ACAB between January 2005 and December 2012 from a single-center cohort. A ACAB lesion was defined as a symptomatic unilateral common iliac artery stenosis (>50%) combined with intermediate stenosis (30%-50%) in the contralateral common iliac artery ostium. The primary end point was the primary patency of the ACAB. The baseline clinical characteristics did not differ significantly between the single-stent and the kissing-stents group. Technical success was achieved in all patients. The single-stent group required fewer stents (1.3 ± 0.5 vs 2.3 ± 0.8; P < .001) and less bilateral femoral access (55% vs 100%; P < .001). Two patients in the single-stent group (3%) required bailout kissing stents because of plaque shift to the contralateral side. The major complication rates were 8% in single-stent vs 13% in the kissing-stent group, which was similar (P = .399). At 3 years, the single-stent and kissing-stents group had similar rates of primary patency (89% vs 87%; P = .916) and target lesion revascularization-free survival (93% vs 87%; P = .462). The single-stent technique in ACAB was safe and showed midterm outcomes comparable with those of kissing stents. Considering the benefits, such as fewer stents, less bilateral femoral access, and the availability of contralateral access for future intervention, the single-stent technique may be an advantageous treatment option in ACAB. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Spectral Imaging for Intracranial Stents and Stent Lumen.

    PubMed

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P < .05) and showed the highest mean grading score (2.94 ± 0.94; P < .05) and contrast/noise ratio of in-stent lumen (160.03 ±37.79; P < .05) among all the modes. Iodine (water) images can help reduce stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  2. Percutaneous biliary covered stent insertion in patients with malignant duodenobiliary obstruction.

    PubMed

    Lee, Eunsol; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki; Shin, Ji Hoon; Kim, Jin Hyoung; Ko, Heung Kyu; Song, Ho-Young

    2015-02-01

    Although the use of polytetrafluoroethylene (PTFE)-covered biliary stents has proven to be feasible for the treatment of benign and malignant biliary disease, less is known regarding the outcomes of percutaneous placement of a covered stent in patients with malignant duodenobiliary obstruction. To investigate the technical and clinical efficacy of the percutaneous placement of a PTFE-covered biliary stent in patients with malignant duodenobiliary obstruction. From April 2007 to September 2012, the medical records of 45 consecutive patients with malignant duodenobiliary obstruction were retrospectively reviewed. All percutaneous biliary stent deployment was performed using PTFE-covered stents, whereas duodenal stent insertion was performed either fluoroscopically or endoscopically using covered or uncovered stents. Biliary stent deployment was technically successful in all patients. None of the stents migrated after deployment. Procedure-related minor complications, including self-limiting hemobilia, occurred in three (7%) patients. Successful internal drainage was achieved in 39 (87%) of the 45 patients. The median survival time after biliary stent placement was 62 days (95% confidence interval, 8-116 days), and the cumulative stent patency rates at 1, 3, 6, and 12 months were 96%, 92%, 75%, and 38%, respectively. The causes of biliary stent dysfunction included stent occlusion caused by a subsequently inserted duodenal stent (n = 7), food impaction (n = 3), and sludge incrustation (n = 1). One patient developed acute cholecystitis 131 days after biliary stent placement and underwent percutaneous transhepatic gallbladder drainage. Percutaneous insertion of a PTFE-covered stent is a safe and effective method for palliative treatment of patients with malignant duodenobiliary obstruction. If possible, subsequent biliary stent insertion is preferable in order to prevent possible biliary stent dysfunction caused by subsequent insertion of a duodenal stent. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Plastic biliary stent patency in patients with locally advanced pancreatic adenocarcinoma receiving downstaging chemotherapy.

    PubMed

    Ge, Phillip S; Hamerski, Christopher M; Watson, Rabindra R; Komanduri, Srinadh; Cinnor, Birtukan B; Bidari, Kiran; Klapman, Jason B; Lin, Cui L; Shah, Janak N; Wani, Sachin; Donahue, Timothy R; Muthusamy, V Raman

    2015-02-01

    Plastic stents in patients with biliary obstruction caused by pancreatic adenocarcinoma are typically exchanged at 3-month intervals. Plastic stents may have reduced durability in patients receiving chemotherapy. To determine the duration of plastic biliary stent patency in patients undergoing chemotherapy for pancreatic adenocarcinoma. Retrospective, multicenter cohort study. Three tertiary academic referral centers. A total of 173 patients receiving downstaging chemotherapy for locally advanced or borderline resectable pancreatic adenocarcinoma from 1996 to 2013. Placement of 10F or larger plastic biliary stents. Primary outcome was overall duration of stent patency. Secondary outcomes included the incidence of premature stent exchange (because of cholangitis or jaundice) and hospitalization rates. A total of 233 plastic stents were placed, and the overall median duration of stent patency was 53 days (interquartile range [IQR] 25-99 days). Eighty-seven stents were removed at the time of surgical resection, and 63 stents were exchanged routinely per protocol. The remaining 83 stent exchanges were performed for worsening liver function test results, jaundice, or cholangitis, representing a 35.6% rate of premature stent exchange. The median stent patency duration in the premature stent exchange group was 49 days (IQR 25-91 days) with a 44.6% hospitalization rate. The overall rate of cholangitis was 15.0% of stent exchanges, occurring a median of 56 days after stent placement (IQR 26-89 days). Retrospective study. Plastic biliary stents placed during chemotherapy/chemoradiation for pancreatic adenocarcinoma have a shorter-than-expected patency duration, and a substantial number of patients will require premature stent exchange. Consideration should be given to shortening the interval for plastic biliary stent exchange. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomised controlled trials.

    PubMed

    Cassese, Salvatore; Byrne, Robert A; Ndrepepa, Gjin; Kufner, Sebastian; Wiebe, Jens; Repp, Janika; Schunkert, Heribert; Fusaro, Massimiliano; Kimura, Takeshi; Kastrati, Adnan

    2016-02-06

    Bioresorbable coronary stents might improve outcomes of patients treated with percutaneous coronary interventions. The everolimus-eluting bioresorbable vascular scaffold is the most studied of these stent platforms; however, its performance versus everolimus-eluting metallic stents remains poorly defined. We aimed to assess the efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents in patients with ischaemic heart disease treated with percutaneous revascularisation. We searched Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL), scientific sessions abstracts, and relevant websites for randomised trials investigating everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents published or posted between Nov 30, 2006, and Oct 12, 2015. The primary efficacy outcome was target lesion revascularisation and the primary safety outcome was definite or probable stent (scaffold) thrombosis. Secondary outcomes were target lesion failure (the composite of cardiac death, target-vessel myocardial infarction, or ischaemia-driven target lesion revascularisation), myocardial infarction, death, and in-device late lumen loss. We derived odds ratios (ORs) and weighted mean differences with 95% CIs, and calculated the risk estimates for the main outcomes according to a random-effects model. This study is registered with PROSPERO, number CRD42015026374. We included six trials, comprising data for 3738 patients randomised to receive percutaneous coronary intervention with either an everolimus-eluting bioresorbable vascular scaffold (n=2337) or an everolimus-eluting metallic stent (n=1401). Median follow-up was 12 months (IQR 9-12). Patients treated with bioresorbable vascular scaffolds had a similar risk of target lesion revascularisation (OR 0.97 [95% CI 0.66-1.43]; p=0.87), target lesion failure (1.20 [0.90-1.60]; p=0.21), myocardial infarction (1.36 [0.98-1.89]; p=0.06), and death (0.95 [0.45-2.00]; p=0.89) as those treated with metallic stents. Patients treated with a bioresorbable vascular scaffold had a higher risk of definite or probable stent thrombosis than those treated with a metallic stent (OR 1.99 [95% CI 1.00-3.98]; p=0.05), with the highest risk between 1 and 30 days after implantation (3.11 [1.24-7.82]; p=0.02). Lesions treated with a bioresorbable vascular scaffold had greater in-device late lumen loss than those treated with a metallic stent (weighted mean difference 0.08 [95% CI 0.05-0.12]; p<0.0001). Compared with everolimus-eluting metallic stents, everolimus-eluting bioresorbable vascular scaffolds had similar rates of repeat revascularisation at 1 year of follow-up, despite inferior mid-term angiographic performance. However, patients treated with a bioresorbable vascular scaffold had an increased risk of subacute stent thrombosis. Studies with extended follow-up in a larger number of patients are needed to fully assess the long-term advantages of everolimus-eluting bioresorbable vascular scaffolds. None. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    PubMed

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  6. Development and evaluation of a centralised computerised registry for ureteric stents: completing the audit cycle.

    PubMed

    Davis, N F; Murray, G; O'Connor, T; Browne, C; MacCraith, E; Galvin, D; Mulvin, D; Quinlan, D; Lennon, G

    2017-11-01

    A forgotten ureteric stent may result in severe renal impairment leading to nephrectomy. To compare the effectiveness of a centralised computerised registry for monitoring ureteric stent activity with a previously established theatre stent logbook system. This prospective audit was performed in two 9-monthly intervals. During the first interval, insertion/removal of a ureteric stent was documented in a specific theatre stent logbook. In the second interval, an electronic centralised computerised registry was developed to document insertion/removal of a ureteric stent onto an accessible hospital server. A computerised traffic-light system was also developed to identify patients with an indwelling stent for >3 months. The primary outcome variable was the number of prolonged indwelling ureteric stents in both groups. During the first time interval, 188 ureteric stents were inserted and 182 (96%) were removed or changed. Six (4%) patients underwent insertion of a ureteric stent for a prolonged period of time (>6 months). This subgroup required complex endourological intervention for stent removal due to encrustation. During the second time interval, 157 ureteric stents were inserted and all patients had their stent removed or changed within 6 months. No patients in this group were lost to follow-up. This study demonstrates that a centralised computerised ureteric stent registry is superior to a conventional logbook for monitoring ureteric stent activity. We propose the introduction a centralised nationalised ureteric stent registry for eliminating the potential for prolonged or forgotten ureteric stents.

  7. Cost analysis of iliac stenting performed in the operating room and the catheterization lab: A case-control study.

    PubMed

    Kim, Sooyeon; Kramer, Sage P; Dugan, Adam J; Minion, David J; Gurley, John C; Davenport, Daniel L; Ferraris, Victor A; Saha, Sibu P

    2016-12-01

    Iliac arterial stenting is performed both in the operating room (OR) and the catheterization lab (CL). To date, no analysis has compared resource utilization between these locations. Consecutive patients (n = 105) treated at a single center were retrospectively analyzed. Patients included adults with chronic, symptomatic iliac artery stenosis with a minimum Rutherford classification (RC) of 3, treated with stents. Exclusion criteria were prior stenting, acute ischemia, or major concomitant procedures. Immediate and two-year outcomes were observed. Patient demographics, perioperative details, physician billings, and hospital costs were recorded. Multivariable regression was used to adjust costs by patient and perioperative cost drivers. Fifty-one procedures (49%) were performed in the OR and 54 (51%) in the CL. Mean age was 57, and 44% were female. Severe cases were more often performed in the OR (RC ≥ 4; 42% vs. 11%, P < 0.001) and were associated with increased total costs (P < 0.01). OR procedures more often utilized additional stents (stents ≥ 2; 61% vs. 46%, P = 0.214), thrombolysis (12% vs. 0%, P = 0.011), cut-down approach (8% vs. 0%, P = 0.052), and general anesthesia (80% vs. 0%, P < 0.001): these were all associated with increased costs (P < 0.05). After multivariable regression, location was not a predictor of procedure room or total costs but was associated with increased professional fees. Same-stay (5%) and post-discharge reintervention (33%) did not vary by location. The OR was associated with increased length of stay, more ICU admissions, and increased total costs. However, OR patients had more severe disease and therefore often required more aggressive intervention. After controlling for these differences, procedure venue per se was not associated with increased costs, but OR cases incurred increased professional fees due to dual-provider charges. Given the similar clinical results between venues, it seems reasonable to perform most stenting in the CL or utilize conscious sedation in the OR. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  8. Self-Expandable Metal Stents for Persisting Esophageal Variceal Bleeding after Band Ligation or Injection-Therapy: A Retrospective Study.

    PubMed

    Müller, Martin; Seufferlein, Thomas; Perkhofer, Lukas; Wagner, Martin; Kleger, Alexander

    2015-01-01

    Despite a pronounced reduction of lethality rates due to upper gastrointestinal bleeding, esophageal variceal bleeding remains a challenge for the endoscopist and still accounts for a mortality rate of up to 40% within the first 6 weeks. A relevant proportion of patients with esophageal variceal bleeding remains refractory to standard therapy, thus making a call for additional tools to achieve hemostasis. Self-expandable metal stents (SEMS) incorporate such a tool. We evaluated a total number of 582 patients admitted to our endoscopy unit with the diagnosis "gastrointestinal bleeding" according to our documentation software between 2011 and 2014. 82 patients suffered from esophageal variceal bleeding, out of which 11 cases were refractory to standard therapy leading to SEMS application. Patients with esophageal malignancy, fistula, or stricture and a non-esophageal variceal bleeding source were excluded from the analysis. A retrospective analysis reporting a series of clinically relevant parameters in combination with bleeding control rates and adverse events was performed. The initial bleeding control rate after SEMS application was 100%. Despite this success, we observed a 27% mortality rate within the first 42 days. All of these patients died due to non-directly hemorrhage-associated reasons. The majority of patients exhibited an extensive demand of medical care with prolonged hospital stay. Common complications were hepatic decompensation, pulmonary infection and decline of renal function. Interestingly, we found in 7 out of 11 patients (63.6%) stent dislocation at time of control endoscopy 24 h after hemostasis or at time of stent removal. The presence of hiatal hernia did not affect obviously stent dislocation rates. Refractory patients had significantly longer hospitalization times compared to non-refractory patients. Self-expandable metal stents for esophageal variceal bleeding seem to be safe and efficient after failed standard therapy. Stent migration appeared to be a common incident that did not lead to reactivation of bleeding in any of our patients. SEMS should be considered a reasonable treatment option for refractory esophageal variceal bleeding after treatment failure of ligature and sclerotherapy and non-availability of or contraindication for other measures (e.g. TIPS).

  9. Comparative assessment of three drug eluting stents with different platforms but with the same biodegradable polymer and the drug based on quantitative coronary angiography and optical coherence tomography at 12-month follow-up.

    PubMed

    Gil, Robert J; Bil, Jacek; Legutko, Jacek; Pawłowski, Tomasz; Gil, Katarzyna E; Dudek, Dariusz; Costa, Ricardo A

    2018-03-01

    The aim of this study was to compare neointima proliferation in three drug-eluting stents (DES) produced by the same company (Balton, Poland) which are covered with a biodegradable polymer and elute sirolimus (concentration: 1.0 and 1.2 µg/mm 2 ), but have different stent platforms and strut thickness: stainless steel Prolim ® (115 µm) and BiOSS LIM ® (120 µm) and cobalt-chromium Alex ® (70 µm). We analyzed data of patients with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 12 months from BiOSS LIM Registry, Prolim Registry and Alex OCT clinical trial. There were 56 patients enrolled, in whom 29 Prolim ® stents were deployed, in 11-BiOSS LIM ® and in 16-Alex stents. The late lumen loss was the smallest in Prolim ® subgroup (0.26 ± 0.17 mm) and did not differ from Alex ® subgroup (0.28 ± 0.47 mm). This parameter was significantly bigger in BiOSS ® subgroup (0.38 ± 0.19 mm; p < 0.05). In OCT analysis there was no statistically significant difference between Prolim ® and Alex ® subgroups in terms of mean neointima burden (24.6 ± 8.6 vs. 19.27 ± 8.11%) and neointima volume (28.16 ± 15.10 vs. 24.51 ± 17.64 mm 3 ). In BiOSS ® group mean neointima burden (30.9 ± 6.2%) and mean neointima volume (44.9 ± 4.9 mm 3 ) were significantly larger. The morphological analysis revealed that in most cases in all groups the neointima was homogenous with plaque presence only around stent struts. In the QCA and OCT analysis regular DES (Prolim ® and Alex ® ) obtained similar results, whereas more pronounced response from the vessel wall was found in the BiOSS ® subgroup.

  10. Comparing the effectiveness and safety between triple antiplatelet therapy and dual antiplatelet therapy in type 2 diabetes mellitus patients after coronary stents implantation: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Bundhun, Pravesh Kumar; Qin, Tao; Chen, Meng-Hua

    2015-10-09

    Since antiplatelet therapy in type 2 diabetes mellitus (T2DM) patients is very important after intracoronary stenting, and because the most commonly used therapies have been the dual antiplatelet therapy (DAPT) consisting of aspirin and clopidogrel and the triple antiplatelet therapy (TAPT) consisting of aspirin, clopidogrel and cilostazol, we aim to compare the effectiveness and safety between triple antiplatelet therapy and dual antiplatelet therapy in T2DM patients. Systematic literature search was done from the databases of PubMed, Cochrane, Embase, China National Knowledge Infrastructure (CNKI) and WanFang. Randomized controlled trials (RCTs) comparing the effectiveness and safety between triple therapy and dual therapy in T2DM patients after coronary stents placement were included. Endpoints included major adverse cardiac effects (MACEs), target lesion revascularization (TLR), target vessel revascularization (TVR), death, stent thrombosis, bleeding and adverse drug reactions during a 9-12 months period, as well as platelet activities. Four studies including 1005 patients reporting the adverse clinical outcomes and six studies including 519 patients reporting the platelet activities, with a total of 1524 patients have been analyzed in this meta-analysis. The pooling analysis shows that TAPT has significantly decreased the occurrence of MACEs (RR: 0.55; 95 % CI: 0.36-0.86, P = 0.009), TLR (RR 0.41; 95 % CI: 0.21-0.80, P = 0.008), TVR (RR 0.55; 95 % CI: 0.34-0.88, P = 0.01) and the overall incidence of Death/ Myocardial Infarction (MI)/TVR (RR 0.54; 95 % CI: 0.31-0.94, P = 0.03) during this 9 to 12 months follow up period after stents implantation. Stent thrombosis was almost similar in both groups. Bleeding seemed to favor DAPT but the result was not statistically significant. Platelet aggregation, platelet reactivity index (PRI) and platelet reactivity unit (PRU) were also reduced with Weight Mean Difference (WMD) of (-13.80; 95 % CI: -17.03 to -10.56, P < 0.00001), (-22.87; 95 % CI: -23.66 to -22.07, P < 0.00001) and (-44.17; 95 % CI: -58.56 to -29.77, P < 0.00001) respectively. Since MACEs have been significantly decreased in the triple group, TAPT appears to be more effective than DAPT in T2DM patients after intracoronary stenting. No significant difference in stent thrombosis and bleeding risks between these 2 groups shows TAPT to be almost as safe as DAPT in these diabetic patients.

  11. Different predictive values of interim 18F-FDG PET/CT in germinal center like and non-germinal center like diffuse large B-cell lymphoma.

    PubMed

    Kim, Jihyun; Lee, Jeong-Ok; Paik, Jin Ho; Lee, Won Woo; Kim, Sang Eun; Song, Yoo Sung

    2017-01-01

    Diffuse large B-cell lymphoma (DLBCL) is a pathologically heterogeneous disease with different prognoses according to its molecular profiles. Despite the broad usage of 18 F-fluoro-2-dexoxy-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT), previous studies that have investigated the value of interim 18 F-FDG PET/CT in DLBCL have given the controversial results. The purpose of this study was to evaluate the prognostic value of interim 18 F-FDG PET/CT in DLBCL according to germinal center B cell-like (GCB) and non-GCB molecular profiling. We enrolled 118 newly diagnosed DLBCL patients treated with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisolone (R-CHOP). Interim 18 F-FDG PET/CT scans performed after 2 or 3 cycles of R-CHOP treatment were evaluated based on the Lugano response criteria. Patients were grouped as GCB or non-GCB molecular subtypes according to immunohistochemistry results of CD10, BCL6, and MUM1, based on Hans' algorithm. In total 118 DLBCL patients, 35 % were classified as GCB, and 65 % were classified as non-GCB. Interim PET/CT was negative in 70 %, and positive in 30 %. During the median follow-up period of 23 months, the positive interim 18 F-FDG PET/CT group showed significantly inferior progression free survival (PFS) compared to the negative interim 18 F-FDG PET/CT group (P = 0.0004) in entire patients. A subgroup analysis according to molecular profiling demonstrated significant difference of PFS between the positive and negative interim 18 F-FDG PET groups in GCB subtype of DLBCL (P = 0.0001), but there was no significant difference of PFS between the positive and negative interim 18 F-FDG PET groups in non-GCB subtype of DLBCL. Interim 18 F-FDG PET/CT scanning had a significant predictive value for disease progression in patients with the GCB subtype of DLBCL treated with R-CHOP, but not in those with the non-GCB subtype. Therefore, molecular profiles of DLBCL should be considered for interim 18 F-FDG PET/CT practice.

  12. Bacteriology of urinary tract infection associated with indwelling J ureteral stents.

    PubMed

    Kehinde, Elijah O; Rotimi, Vincent O; Al-Hunayan, Adel; Abdul-Halim, Hamdy; Boland, Fareeda; Al-Awadi, Khaleel A

    2004-11-01

    To investigate the microorganisms responsible for urinary tract infection (UTI) and stent colonization in patients with indwelling J ureteral stents and to compare the antimicrobial susceptibility pattern of the isolates from urine and J stents in order to establish the etiologic agents of bacteriuria and colonized stents in such patients and provide baseline data on an antibiotic policy for the urology unit. Midstream urine from 250 patients requiring J stent insertion was investigated microbiologically prior to stent insertion and on the day of stent removal. After stent removal, 3 to 5 cm of the tip located in the bladder was also sent for culture. Patients' bio-data and underlying diseases were documented. Those with no known systemic diseases ("normal patients") were also studied as controls. Of the 250 patients studied, 152 (61%) were normal, while 27 (11%), 53 (21%), and 18 (7%) had diabetes mellitus (DM), chronic renal failure (CRF), and diabetic nephropathy (DN), respectively. The mean duration of stent retention was 27 days. All microbial isolates were tested for their susceptibility to a panel of 10 antibiotics. Twelve patients (5%) before stent insertion and 42 patients (17%; P < 0.001) on the day of stent removal had positive urine cultures. One hundred four stents (42%) were culture positive. Of the 104 patients with positive stent cultures, in 62 patients (60%), urine culture was sterile. The commonest isolates were Escherichia coli, Enterococcus spp., Staphylococcus spp., Pseudomonas, and Candida spp. On the day of stent removal, urine culture was positive in 28% of the normal patients compared with 57% (P = 0.11), 78% (P < 0.001), and 62% (P < 0.001) of patients with CRF, DM, and DN, respectively. Stent isolates were more resistant to antibiotics than the organism isolated before stent insertion. An indwelling J ureteral stent carries a significant risk of bacteriuria and stent colonization. The sensitivity of urine culture to stent colonization is low, and therefore, a negative culture does not rule out a colonized stent. Bacteria cultured from urine after stent insertion and from the stents are more resistant to antibiotics than are those cultured from urine before stent insertion. Norfloxacin or ciprofloxacin is recommended as prophylaxis prior to stent insertion, and an aminoglycoside can be added to treat symptomatic patients with severe infections.

  13. Endoscopic Biliary Stenting Versus Percutaneous Transhepatic Biliary Stenting in Advanced Malignant Biliary Obstruction: Cost-effectiveness Analysis.

    PubMed

    Sun, Xin Rong; Tang, Cheng Wu; Lu, Wen Ming; Xu, Yong Qiang; Feng, Wen Ming; Bao, Yin; Zheng, Yin Yuan

    2014-05-01

    This study aims to compare the clinical outcomes and costs between endoscopic biliary stenting (EBS) and percutaneous transhepatic biliary stenting (PTBS). We randomly assigned 112 patients with unresectable malignant biliary obstruction 2006 and 2011 to receive EBS or PTBS with self-expandable metal stent (SEMS) as palliative treatment. PTBS was successfully performed in 55 patients who formed the PTBS group (failed in 2 patients). EBS was successfully performed in 52 patients who formed the EBS group (failed in 3 patients). The effectiveness of biliary drainage, hospital stay, complications, cost, survival time and mortality were compared. Patients in PTBS group had shorter hospital stay and lower initial and overall expense than the BBS group (P < 0.05). There was no significant difference in effectiveness of biliary drainage (P = 0.9357) or survival time between two groups (P = 0.6733). Early complications occurred in PTBS group was significantly lower than in EBS group (3/55 vs 11/52, P = 0.0343). Late complications in the EBS group did not differ significantly from PTBS group (7/55 vs 9/52, P = 0.6922). The survival curves in the two groups showed no significant difference (P = 0.5294). Conclusions: 3.

  14. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

    PubMed Central

    Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A

    2003-01-01

    Objectives: To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Methods: Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). Results: No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Conclusion: Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants. PMID:12748224

  15. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

    PubMed

    Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A

    2003-06-01

    To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants.

  16. The forgotten ureteric JJ stent and its prevention: a prospective audit of the value of a ureteric stent logbook.

    PubMed

    Thomas, A Z; Casey, R G; Grainger, R; McDermott, T; Flynn, R; Thornhill, J A

    2007-01-01

    Temporary ureteric stent insertion is an integral part of modern endo-urological practice. Delayed stent removal or forgotten stents are associated with increased patient morbidity and complications which are often difficult to manage. We prospectively audited our ureteric stent insertion and removal logbook system to determine the value and effectiveness of our stent follow-up. Over a 1-year period, 210 ureteric stents were inserted in our urological unit. Of these, 47 (22.4%) patients were unaccounted as having their stents removed within the stent logbooks. One patient was lost to follow-up and re-presented with stent encrustation 10 months later. Our results in this audit suggest that our system of ureteric stent follow-up is not effective. We have now introduced a new system that we feel is a safer and a satisfactory alternative to the stent logbooks. This includes a patient education leaflet and removal date scheduling prior to discharge from hospital.

  17. Genous™ endothelial progenitor cell capturing stent vs. the Taxus Liberté stent in patients with de novo coronary lesions with a high-risk of coronary restenosis: a randomized, single-centre, pilot study

    PubMed Central

    Beijk, Marcel A.M.; Klomp, Margo; Verouden, Niels J.W.; van Geloven, Nan; Koch, Karel T.; Henriques, José P.S.; Baan, Jan; Vis, Marije M.; Scheunhage, Esther; Piek, Jan J.; Tijssen, Jan G.P.; de Winter, Robbert J.

    2010-01-01

    Aims The purpose of this study was to evaluate the GenousTM endothelial progenitor cell capturing stent vs. the Taxus Liberté paclitaxel-eluting stent in patients with de novo coronary lesions with a high-risk of coronary restenosis. Methods and results We randomly assigned 193 patients with lesions carrying a high risk of restenosis to have the Genous stent or the Taxus stent implanted. Lesions were considered high risk of restenosis if one of the following applied: chronic total occlusion, lesion length >23 mm, vessel diameter <2.8 mm, or any lesion in a diabetic patient. At 1-year, the rate of the primary end point, target vessel failure (TVF), was 17.3% in the Genous stent group when compared with 10.5% in the Taxus stent group [risk difference (RD) 6.8%, 95% CI −3.1 to 16.7%], a difference predominantly due to a higher incidence of repeat revascularization in patients treated with the Genous stent. In contrast, no stent thrombosis was observed in the Genous stent group compared to 4 stent thromboses in the Taxus stent group (RD −4.2%; 95% CI −10.3 to 0.3%). Repeat angiography between 6 and 12 months in a subgroup of patients showed a significantly higher late loss in the Genous stent compared with the Taxus stent (1.14 ± 0.64 and 0.55 ± 0.61 mm). Conclusion In patients with lesions carrying a high risk of restenosis, the Genous stent resulted in a non-significant higher rate of TVF compared with the Taxus stent mainly due to more repeat revascularizations in the Genous stent group. There were four stent thromboses with Taxus stent, none with the Genous stent. PMID:19933225

  18. Usefulness of Corsair microcatheter to cross stent struts in bifurcation lesions.

    PubMed

    Fujimoto, Yoshihide; Iwata, Yo; Yamamoto, Masashi; Kobayashi, Yoshio

    2014-01-01

    Side branch compromise after stenting in bifurcation lesions is a matter of concern. It may happen that even low-profile balloon catheters do not cross stent struts after rewiring. The Corsair catheter is a hybrid catheter that has features of a microcatheter and a support catheter. The present study evaluated usefulness of the Corsair catheter to facilitate advancing a low-profile balloon catheter through stent struts in bifurcation lesions. After rewiring, low-profile balloon catheters failed to cross stent struts of 29 bifurcation lesions. The Corsair microcatheter successfully crossed stent struts in all lesions except one (97 %) where a stent was implanted to treat in-stent restenosis (stent-in-stent). Low-profile balloon catheters were able to advance into the side branch of all bifurcation lesions where the Corsair microcatheter crossed stent struts. In conclusion, the Corsair microcatheter may be utilized if low-profile balloon catheters are unable to cross stent struts in bifurcation lesions.

  19. Status update and interim results from the asymptomatic carotid surgery trial-2 (ACST-2).

    PubMed

    Halliday, Alison; Bulbulia, Richard; Gray, William; Naughten, Ally; den Hartog, Anne; Delmestri, Antonella; Wallis, Carol; le Conte, Stephanie; Macdonald, Sumaira

    2013-11-01

    ACST-2 is currently the largest trial ever conducted to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in patients with severe asymptomatic carotid stenosis requiring revascularization. Patients are entered into ACST-2 when revascularization is felt to be clearly indicated, when CEA and CAS are both possible, but where there is substantial uncertainty as to which is most appropriate. Trial surgeons and interventionalists are expected to use their usual techniques and CE-approved devices. We report baseline characteristics and blinded combined interim results for 30-day mortality and major morbidity for 986 patients in the ongoing trial up to September 2012. A total of 986 patients (687 men, 299 women), mean age 68.7 years (SD ± 8.1) were randomized equally to CEA or CAS. Most (96%) had ipsilateral stenosis of 70-99% (median 80%) with contralateral stenoses of 50-99% in 30% and contralateral occlusion in 8%. Patients were on appropriate medical treatment. For 691 patients undergoing intervention with at least 1-month follow-up and Rankin scoring at 6 months for any stroke, the overall serious cardiovascular event rate of periprocedural (within 30 days) disabling stroke, fatal myocardial infarction, and death at 30 days was 1.0%. Early ACST-2 results suggest contemporary carotid intervention for asymptomatic stenosis has a low risk of serious morbidity and mortality, on par with other recent trials. The trial continues to recruit, to monitor periprocedural events and all types of stroke, aiming to randomize up to 5,000 patients to determine any differential outcomes between interventions. ISRCTN21144362. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Removable esophageal stents have poor efficacy for the treatment of refractory benign esophageal strictures (RBES).

    PubMed

    Dan, D T; Gannavarapu, B; Lee, J G; Chang, K; Muthusamy, V R

    2014-08-01

    With the recent availability of removable esophageal stents, endoscopic stenting has been utilized to treat refractory benign esophageal strictures (RBES). The objective of this study was to review the feasibility and effectiveness of removable esophageal stents to treat RBES. Patients who received removable esophageal stents for the treatment of RBES at the institution between 2004-2010 using its stent implantation logs and endoscopic database were retrospectively identified. Patient demographics, stricture etiology and location, stent and procedure characteristics, and clinical outcomes were obtained. Twenty-five patients with a mean age of 70 (72% male) underwent initial stent placement; 24 were successful. Overall clinical success was achieved in five of the 19 patients (26%) ultimately undergoing stent removal. RBES etiologies included anastomotic (13), radiation (5), peptic (3), chemotherapy (1), scleroderma (1), and unknown (2). Alimaxx-E (Merit-Endotek, South Jordan, UT, USA) stents were placed in 20 patients and Polyflex (Boston Scientific, Natick, MA, USA) stents were used in five patients. Immediate complications included failed deployment (1) and chest pain (7). Five patients died prior to stent removal. Stent migration was found in 53% (10/19) of patients who underwent stent removal: nine required additional therapy and one had symptom resolution. Out of the nine patients without stent migration, five required additional therapy and four had symptom resolution. Although placement of removable esophageal stents for RBES is technically feasible, it is frequently complicated by stent migration and chest pain. In addition, few patients achieved long-term stricture resolution after initial stenting. In this study, most patients ultimately required repeated stenting and/or dilations to maintain relief of dysphagia. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

Top