Step-off, vertical electromagnetic responses of a deep resistivity layer buried in marine sediments
NASA Astrophysics Data System (ADS)
Jang, Hangilro; Jang, Hannuree; Lee, Ki Ha; Kim, Hee Joon
2013-04-01
A frequency-domain, marine controlled-source electromagnetic (CSEM) method has been applied successfully in deep water areas for detecting hydrocarbon (HC) reservoirs. However, a typical technique with horizontal transmitters and receivers requires large source-receiver separations with respect to the target depth. A time-domain EM system with vertical transmitters and receivers can be an alternative because vertical electric fields are sensitive to deep resistive layers. In this paper, a time-domain modelling code, with multiple source and receiver dipoles that are finite in length, has been written to investigate transient EM problems. With the use of this code, we calculate step-off responses for one-dimensional HC reservoir models. Although the vertical electric field has much smaller amplitude of signal than the horizontal field, vertical currents resulting from a vertical transmitter are sensitive to resistive layers. The modelling shows a significant difference between step-off responses of HC- and water-filled reservoirs, and the contrast can be recognized at late times at relatively short offsets. A maximum contrast occurs at more than 4 s, being delayed with the depth of the HC layer.
Spring 2016 @NWTC Newsletter | Wind | NREL
Proves Wind Can Provide Ancillary Grid Fault Response One Step Closer to the Marketplace for State-of-the dynamometer. Photo by Malone Media. One Step Closer to the Marketplace for State-of-the-Art Wind Turbine power converter. More A meteorological tower in the background, one wind turbine in the front, and one
One-Step Device Converts Water, Sunlight Into Fuel of the Future
great promise that through further research the technology can bring down the cost of using water and One-Step Device Converts Water, Sunlight Into Fuel of the Future For more information contact the world's most abundant resources, water and sunlight, to directly generate hydrogen, a non
Online Quadrat Study - Site Index
Study Project - Prairie Advocates Project ) Background Information - Data Collection and Entry - Data Data Entry Data Summaries and Graphs Quadrat Study Poster for your classroom. Directions for Looking at by Prairie Study Prairie Experts For Non-Fermilab Prairie researchers: Complete step-by-step
Encke-Beta Predictor for Orion Burn Targeting and Guidance
NASA Technical Reports Server (NTRS)
Robinson, Shane; Scarritt, Sara; Goodman, John L.
2016-01-01
The state vector prediction algorithm selected for Orion on-board targeting and guidance is known as the Encke-Beta method. Encke-Beta uses a universal anomaly (beta) as the independent variable, valid for circular, elliptical, parabolic, and hyperbolic orbits. The variable, related to the change in eccentric anomaly, results in integration steps that cover smaller arcs of the trajectory at or near perigee, when velocity is higher. Some burns in the EM-1 and EM-2 mission plans are much longer than burns executed with the Apollo and Space Shuttle vehicles. Burn length, as well as hyperbolic trajectories, has driven the use of the Encke-Beta numerical predictor by the predictor/corrector guidance algorithm in place of legacy analytic thrust and gravity integrals.
Blue steps Blue steps Indoor Environment Department Advice for Safeguarding Buildings Against Chemical building operators. It contains our current advice for dealing with a biological or chemical release in a protecting buildings and occupants from chemical or biological attack. Click on the title bar, above, for
Publications - GMC 426 | Alaska Division of Geological & Geophysical
DGGS GMC 426 Publication Details Title: 40Ar/39Ar step heat analyses of core from the N. Kalikpik Test Layer, P.W., 2014, 40Ar/39Ar step heat analyses of core from the N. Kalikpik Test Well #1: Alaska
Alshahrani, Mohammed S
2017-01-01
To assess the effect of the mode of transportation of trauma patients (emergency medical service [EMS] vs. non-EMS) on their final clinical outcome in terms of mortality and length of hospital stay. A retrospective study included all patients who were involved in motor vehicle crashes, and who were transferred immediately to an emergency department of a trauma care center from December 2008 to December 2012. Patients were classified into two groups: those brought through EMS and those brought by non-EMS (private transport). Information on demographic characteristics including age and gender was recorded and medical data such as blood pressure, pulse, oxygen saturation, temperature, initial Glasgow Coma Score (GCS), saturation, temperature, initial Glasgow Coma Score (GCS), injury severity score (ISS), and final outcome (discharged or expired) were obtained. Descriptive statistics, mean and standard deviation (SD) were computed for continuous variables and statistical significance was tested by t -test or Mann-Whitney U-test. Categorical variables were described by frequency distribution and percentages; Chi-square or Fisher's exact test as appropriate were employed to test for statistical significance. Logistics regression was performed with mortality as dependent variable and mode of transport and all demographic and prehospital variables as independent variables. A general linear model analysis was performed to test whether the mode of transport was significant to length of hospital stay in EMS and non-EMS clients. Out of 308 patients identified during the study period, 232 were transported through EMS and 76 through non-EMS. The two groups were similar with regard to mortality and length of stay. The crude mortality rate was 30.6% (95% confidence interval [CI]: 24.64-36.53) in the EMS group and 28.9% (95% CI: 18.44-38.76) in the non-EMS group ( p = 0.785). The average length of hospital stay was 9 days (interquartile range [IQR] = 8, 95% CI: 7.3-10.1) for the EMS group and 8 days (IQR = 9.5, 95% CI: 6.7-10.9) for the non-EMS group ( p = 0.803). Multivariate analysis showed that of the study variables, only the injury severity score (ISS) and Glasgow coma score (GCS) were significant to mortality ( p < 0.01), and GCS was more significant to the length of hospital stay ( p < 0.01). There was no significant difference between the EMS and non-EMS groups as they relate to mortality and length of stay in hospital. However, the mortality and length of hospital stay was statistically significant to ISS and GCS.
listed on the NRHP as a nationally significant historic property; (c) Hagerman Fossil Beds National Programmatic Agreement Sets New Standard for the BLM The Gateway West Transmission Line is an interstate and Boise, Idaho. With a length of approximately 1,000 miles, the 300 foot-wide right-of-way may involve
Berkeley Lab - Materials Sciences Division
Synthesis Condensed Matter and Materials Physics Scattering and Instrumentation Science Centers Center for materials and phenomena at multiple time and length scales. Through our core programs and research centers Berkeley Lab Berkeley Lab A-Z Index Phone Book Jobs Search DOE Search MSD Go MSD - Materials
Facts About Derechos - Very Damaging Windstorms
or bowed shape. The bow-shaped storms are called bow echoes.  Bow echoes typically arise when thunderstorms (typically from 40 miles to 250 miles in length) that may at times take the shape of a single bow yield vastly different outcomes --- that is, a derecho or no derecho --- depending upon how the
ACHP | Defense Department Compliance with NHPA
NHPA: Section 202(a)(6) Evaluation Report Defense Department Compliance with the National Historic )(6) Evaluation Report is a preliminary step in helping the Department of Defense marshall its Search skip specific nav links Home arrow Publications arrow Intro: Defense Department Compliance with
Current Students International Faculty and Staff Continuing Education Alumni Popular Now Photos and Amherst Rising Researchers 2018 Stepping Up to the Challenge UMass Amherst undergraduate students tackle American play UMass students train service dogs UMass students train service dogs Diggity Dogs UMass
Computing Visitors who do not need a HEP linux account Visitors with laptops can use wireless network HEP linux account Step 1: Click Here for New Account Application After submitting the application, you
Concentrating Solar Power Projects - Borges Termosolar | Concentrating
CSP plant is hybridized with two biomass units (2 x 22 MW thermal) that supply the required thermal avoiding daily start-up's and shut downs) and therefore, making possible a better use of the thermal block Manufacturer (Model): Siemens (UVAC 2010) HCE Type (Length): Evacuated (4 m) Heat-Transfer Fluid Type: Thermal
Preserve America: Questions and Answers
preservation efforts and highlight appropriate heritage tourism destinations; and an electronic newsletter , it also directs Federal agencies to take steps to support local preservation and heritage tourism . Tourism is a major national industry, and heritage tourism is fast becoming a significant part of local
Concentrating Solar Power Projects - Kimberlina Solar Thermal Power Plant |
MW Gross: 5.0 MW Status: Currently Non-Operational Start Year: 2008 Do you have more information , corrections, or comments? Background Technology: Linear Fresnel reflector Status: Currently Non-Operational Manufacturer: Ausra Receiver Manufacturer : Ausra Receiver Type: Non-evacuated Receiver Length: 385 m Heat
Structural Research Facilities | Wind | NREL
enable the characterization and validation of wind turbine blades and components. A photo of a wind operating loads experienced by blades during field operation and accelerated fatigue lifetime loading can be are capable of validating blades and components smaller than 1 meter (m) to more than 50 m in length
Pace Speaks Across America - February 21 2007 - U.S. Department of Defense
Washington State, Oregon, Alaska and Florida. Pace Discusses Force Levels, Military Challenges WASHINGTON Iraq, force levels or tour lengths, Marine Gen. Peter Pace is eager to answer frankly and completely
our reports. To order b&w hard copies of 2011 PEER Reports and beyond: PEER no longer keeps copies . Reports are individually priced based on the length of the report. If you are interested in a color hard copy of any reports, contact Replica Digital Ink by email. To order b&w hard copies of PEER Reports
Concentrating Solar Power Basics | NREL
concentrating solar power systems uses the sun as a heat source. The three main types of concentrating solar toward the sun, focusing sunlight on tubes (or receivers) that run the length of the mirrors. The mirrors to allow the mirrors greater mobility in tracking the sun. A dish/engine system uses a mirrored
length in single grains and the effect of grain boundaries in CdTe, and the effects of defects on the diffraction of CdTe thin films: Effects of CdCl2 treatment, J. Vac. Sci. Technol. A 26, 1068 (2008). H.R
Partnering: An Engine for Innovation - Continuum Magazine | NREL
$10 million, five-year agreement at NREL's annual Industry Growth Forum, taking the next step in a positioned than ever before to help move big ideas to market. Industry Growth Forum Cultivates Clean Energy Entrepreneurship Industry Growth Forum Cultivates Clean Energy Entrepreneurship NREL's Industry Growth Forum brings
Climate Action Planning Process | Climate Neutral Research Campuses | NREL
Action Planning Process Climate Action Planning Process For research campuses, NREL has developed a five-step process to develop and implement climate action plans: Determine baseline energy consumption Analyze technology options Prepare a plan and set priorities Implement the climate action plan Measure and
6 News Releases Access news stories about the laboratory and renewable energy and energy efficiency Facility Slashes Energy Use by 66 Percent - (10/3/96) Agreement Moves Nevada Solar Plant Step Closer to Converter Wins National Award - (7/25/96) Solar Energy to Help Heat Major Commercial Facility - (6/21/96
Community - (5/4/98) High School Students Compete in Solar-Powered Bike Race - (4/23/98) New Battery Testing Facility Could Boost Future of Electric Vehicles - (4/21/98) NREL Publications Win Awards - (4/17/98) Local Students Celebrate Earth Day at NREL - (4/17/98) One-Step Device Converts Water, Sunlight Into Fuel of the
Hiller, Katherine; Franzen, Doug; Heitz, Corey; Emery, Matthew; Poznanski, Stacy
2015-11-01
There is great variation in the knowledge base of Emergency Medicine (EM) interns in July. The first objective knowledge assessment during residency does not occur until eight months later, in February, when the American Board of EM (ABEM) administers the in-training examination (ITE). In 2013, the National Board of Medical Examiners (NBME) released the EM Advanced Clinical Examination (EM-ACE), an assessment intended for fourth-year medical students. Administration of the EM-ACE to interns at the start of residency may provide an earlier opportunity to assess the new EM residents' knowledge base. The primary objective of this study was to determine the correlation of the NBME EM-ACE, given early in residency, with the EM ITE. Secondary objectives included determination of the correlation of the United States Medical Licensing Examination (USMLE) Step 1 or 2 scores with early intern EM-ACE and ITE scores and the effect, if any, of clinical EM experience on examination correlation. This was a multi-institutional, observational study. Entering EM interns at six residencies took the EM-ACE in July 2013 and the ABEM ITE in February 2014. We collected scores for the EM-ACE and ITE, age, gender, weeks of clinical EM experience in residency prior to the ITE, and USMLE Step 1 and 2 scores. Pearson's correlation and linear regression were performed. Sixty-two interns took the EM-ACE and the ITE. The Pearson's correlation coefficient between the ITE and the EM-ACE was 0.62. R-squared was 0.5 (adjusted 0.4). The coefficient of determination was 0.41 (95% CI [0.3-0.8]). For every increase of one in the scaled EM-ACE score, we observed a 0.4% increase in the EM in-training score. In a linear regression model using all available variables (EM-ACE, gender, age, clinical exposure to EM, and USMLE Step 1 and Step 2 scores), only the EM-ACE score was significantly associated with the ITE (p<0.05). We observed significant colinearity among the EM-ACE, ITE and USMLE scores. Gender, age and number of weeks of EM prior to the ITE had no effect on the relationship between EM-ACE and the ITE. Given early during intern year, the EM-ACE score showed positive correlation with ITE. Clinical EM experience prior to the in-training exam did not affect the correlation.
Hiller, Katherine; Franzen, Doug; Heitz, Corey; Emery, Matthew; Poznanski, Stacy
2015-01-01
Introduction There is great variation in the knowledge base of Emergency Medicine (EM) interns in July. The first objective knowledge assessment during residency does not occur until eight months later, in February, when the American Board of EM (ABEM) administers the in-training examination (ITE). In 2013, the National Board of Medical Examiners (NBME) released the EM Advanced Clinical Examination (EM-ACE), an assessment intended for fourth-year medical students. Administration of the EM-ACE to interns at the start of residency may provide an earlier opportunity to assess the new EM residents’ knowledge base. The primary objective of this study was to determine the correlation of the NBME EM-ACE, given early in residency, with the EM ITE. Secondary objectives included determination of the correlation of the United States Medical Licensing Examination (USMLE) Step 1 or 2 scores with early intern EM-ACE and ITE scores and the effect, if any, of clinical EM experience on examination correlation. Methods This was a multi-institutional, observational study. Entering EM interns at six residencies took the EM-ACE in July 2013 and the ABEM ITE in February 2014. We collected scores for the EM-ACE and ITE, age, gender, weeks of clinical EM experience in residency prior to the ITE, and USMLE Step 1 and 2 scores. Pearson’s correlation and linear regression were performed. Results Sixty-two interns took the EM-ACE and the ITE. The Pearson’s correlation coefficient between the ITE and the EM-ACE was 0.62. R-squared was 0.5 (adjusted 0.4). The coefficient of determination was 0.41 (95% CI [0.3–0.8]). For every increase of one in the scaled EM-ACE score, we observed a 0.4% increase in the EM in-training score. In a linear regression model using all available variables (EM-ACE, gender, age, clinical exposure to EM, and USMLE Step 1 and Step 2 scores), only the EM-ACE score was significantly associated with the ITE (p<0.05). We observed significant colinearity among the EM-ACE, ITE and USMLE scores. Gender, age and number of weeks of EM prior to the ITE had no effect on the relationship between EM-ACE and the ITE. Conclusion Given early during intern year, the EM-ACE score showed positive correlation with ITE. Clinical EM experience prior to the in-training exam did not affect the correlation. PMID:26594299
addition to the above steps, DOE considered environmental factors in selecting a contractor for the contractor selection process. The environmental synopsis has been incorporated into the EISs. e-mail icon E
DECISION MAKING, DESIGN, AND OPERATIONS Occupant surveys are an invaluable source of information for design features are or are not working, and helps to prioritize the steps needed to improve occupant Assess how new technologies and design strategies impact occupants. document INFORM Improve operations
University of Maryland MRSEC - Education: Professional Development for
"stepped" (we call this type of surface a vicinal surface). Modern scanned-probe microscopes International Educational Education Pre-College Programs Homeschool Programs Undergraduate & Graduate Facilities Logos MRSEC Templates Opportunities Search Home » Education » Teacher Programs Professional
How to Use This Website | USDA Plant Hardiness Zone Map
, regional or national plant hardiness zone maps in three different resolutions using the following steps. To default printing menu option or button. Viewing the Map - Open Full Map Button c. Save Full Map Button can copy the e-mail address and paste it into a different e-mail client (e.g., Google Gmail, Yahoo
One Step Closer to the Marketplace for State-of-the-Art Wind Turbine
engineer and project lead Jonathan Keller, the technology is meeting design projections and working as drivetrain design. The Energy Department funded more than half of the project's $3 million design, build, and test budget. The industry partners supplied expertise, hardware design, development and fabrication
DefenseLink.mil - Special Report - Wounded Care
: Question 21 Walter Reed Strives to Remove Stigma from Mental Health Care Military Works to Eliminate Perceived Mental Health Treatment Stigma Leaders Should Step Up, Receive Mental Health Care if Needed DoD a new telephone hotline and e-mail address to contact for help. Story Military Health System
Understanding Processes and Timelines for Distributed Photovoltaic
data from more than 30,000 PV systems across 87 utilities in 16 states to better understand how solar photovoltaic (PV) interconnection process time frames in the United States. This study includes an analysis of Analysis Metrics" that shows the four steps involved in the utility interconnection process for solar
NREL, Sandia Team to Improve Hydrogen Fueling Infrastructure | News | NREL
hydrogen fuel cell vehicle owners have a positive fueling experience as fuel cell electric vehicles are to pave the way toward more widespread deployment of hydrogen fuel cell electric vehicles. The goals out what's working and what needs improvement is a key next step for fuel cell vehicle deployment
NREL Scientists Demonstrate Remarkable Stability in Perovskite Solar Cells
environmentally stable, high-efficiency perovskite solar cell, bringing the emerging technology a step closer to needed to make the devices durable enough for long-term use. NREL's unencapsulated solar cell-a cell used Unencapsulated Perovskite Solar Cells for >1000 Hours of Operational Stability." "A solar cell in
Labs21 Approach to Climate Neutral Campuses | Climate Neutral Research
Campuses | NREL Labs21 Approach to Climate Neutral Campuses Labs21 Approach to Climate Neutral included a whole-building approach to energy efficiency in laboratory buildings. This website takes that approach a step further in carrying out campus-wide energy- and carbon-reduction strategies. The
CXRO - The Center for X-ray Optics
advanced experimental systems to address national needs, support research in material, life, and provides a stepping stone for realizing stable and highly scalable (10 nm and below) non-volatile memory
Agreement Moves Nevada Solar Plant Step Closer to Reality
Secretary Christine Ervin, CSTRR President Rose McKinney-James and NREL Director Dr. Charles Gay today new partnership, NREL will make available its facilities to test renewable energy technologies, help other renewable technologies. NREL will support the efforts of DOE's Federal Energy Management Program
personnel decisions be made free of discrimination on the basis of race, color, religion, sex, national to take appropriate steps to ensure that all employment decisions are free from discrimination. It Rehabilitation Act programs, which include periodic agency self-assessments and the removal of barriers to free
Net-Zero Building Technologies Create Substantial Energy Savings -
-by-step information for decision making around net-zero energy building technologies. The past three improved insulation, windows, and heating and cooling systems. Despite these strides, energy use by energy building methodologies and technologies during a tour of the RSF's rooftop PV system. Photo by
Board on Science, Technology, and Economic Policy (STEP)
and Medicine Board on Science, Technology, and Economic Policy Board on Science, Technology, and Economic Policy Policy and Global Affairs Home About Us Projects Events Reports by Topic Contact Us -led job growth and economic dynamism to smaller communities across the State of Indiana. Indiana's
ACHP GUIDANCE ON PROGRAM COMMENTS AS A PROGRAM ALTERNATIVE
usual case-by-case basis. Format of this Guidance The following table identifies the steps in the adequate monitoring of issued program comments. Following the table, the ACHP has developed a series of following subject line: "RE: ACHP Program Comment Guidance." Return to Top
career at NREL in 1995 by conducting scanning tunneling microscope (STM) studies of the atomic structure revealed a new strain-induced step structure and contributed to the development of world-record-efficiency NREL's Computational Materials Science team, probing the atomic structure of dislocations in III-V
Breakthroughs Move Researchers One Step Closer to $35 Billion Fuel Savings
representative blendstocks from five chemical families with the greatest promise for reducing energy consumption (Co-Optima) initiative. This national research effort is providing industry with the scientific consumption, improve air quality, and lower drivers' costs. Two new studies reveal how fundamental research
Alternative Fuels Data Center: Oregon Leads the Charge for Plug-In Electric
Governor's Alternative Fuel Vehicle Infrastructure Working Group. This group focused on PEVs for several spending of approximately $8 billion on gasoline and diesel, of which 90% of the non-tax dollars leave the equivalent size) with a maximum of two inspections. Step 4: Install Installing EVSE If the existing
Fermilab | Tritium at Fermilab | Ferry Creek Results
newsletter Ferry Creek Results chart This chart (click chart for larger version) shows the levels of tritium following the detection of low levels of tritium in Indian Creek in November 2005. The levels of tritium in . Fermilab continues to monitor the ponds and creeks on its site and take steps to keep the levels of tritium
NREL Science Central to Success of New Biofuels Projects: DuPont-NREL
without adversely affecting the next step in the process." Long Hours, True Collaboration Meanwhile processes. "This was a true collaboration," said NREL microbiologist Mary Ann Franden, who
Lorelle Mansfield, Ph.D. | NREL
)Se2 (CIGS) thin films for photovoltaic applications. In particular, she is developing rapid two-step content, and band gap grading. While at NREL, she has also deposited CIGS on novel substrates using low
Influence of step length and landing pattern on patellofemoral joint kinetics during running.
Willson, J D; Ratcliff, O M; Meardon, S A; Willy, R W
2015-12-01
Elevated patellofemoral joint kinetics during running may contribute to patellofemoral joint symptoms. The purpose of this study was to test for independent effects of foot strike pattern and step length on patellofemoral joint kinetics while running. Effects were tested relative to individual steps and also taking into account the number of steps required to run a kilometer with each step length. Patellofemoral joint reaction force and stress were estimated in 20 participants running at their preferred speed. Participants ran using a forefoot strike and rearfoot strike pattern during three different step length conditions: preferred step length, long (+10%) step length, and short (-10%) step length. Patellofemoral kinetics was estimated using a biomechanical model of the patellofemoral joint that accounted for cocontraction of the knee flexors and extensors. We observed independent effects of foot strike pattern and step length. Patellofemoral joint kinetics per step was 10-13% less during forefoot strike conditions and 15-20% less with a shortened step length. Patellofemoral joint kinetics per kilometer decreased 12-13% using a forefoot strike pattern and 9-12% with a shortened step length. To the extent that patellofemoral joint kinetics contribute to symptoms among runners, these running modifications may be advisable for runners with patellofemoral pain. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NREL: News - Energy Secretary Abraham Welcomes College Students Who will
is a team competition among universities to design and build the most energy-efficient solar-powered Decathlon, a team must blend aesthetics and modern conveniences with maximum energy production and National Mall marks a significant step forward in innovative residential design, and advanced, energy
NREL: U.S. Life Cycle Inventory Database - Life Cycle Assessments
evaluates the environmental impacts of products, processes, and services. Its quality depends on the life assessment of both goals and potential impacts. From this point, the next data interpretation step evaluates ? The environmental impacts of the shirts occurred during four phases: Production (cotton growing
Report to Congress on Historic Post Offices The public is invited to submit comments to the Advisory Council on Historic Preservation (ACHP) in order to inform its report to Congress on the United State Appropriations Act of 2014 to develop this report on appropriate steps to ensure that the United States Postal
Defense.gov Special Report: Feds Feed Families
Department of Defense Submit Search Feds Feed Families: DOD Delivers - Supporting our Fellow Americans - Food Feed Families Food Drive campaign is now under way. Department of Defense employees nationwide will step up to meet this challenge by gathering 1.5 million pounds of food for families in need this summer
Alternative Fuels Data Center: Lee's Summit R-7 School District Delivers
was the next step. In 2010, the district purchased four all-electric Smith Newton delivery trucks with -based Smith Electric Vehicles educated local fleet operators about the capabilities of its all-electric conventional trucks do, maintenance expenses were drastically reduced. With close proximity to Smith Electric
Subtasks affecting step-length asymmetry in post-stroke hemiparetic walking.
Kim, Woo-Sub
2016-10-01
This study was performed to investigate whether components from trunk progression (TP) and step length were related to step length asymmetry in walking in patients with hemiparesis. Gait analysis was performed for participants with hemiparesis and healthy controls. The distance between the pelvis and foot in the anterior-posterior axis was calculated at initial-contact. Step length was partitioned into anterior foot placement (AFP) and posterior foot placement (PFP). TP was partitioned into anterior trunk progression (ATP) and posterior trunk progression (PTP). The TP pattern and step length pattern were defined to represent intra-TP and intra-step spatial balance, respectively. Of 29 participants with hemiparesis, nine participants showed longer paretic step length, eight participants showed symmetric step length, and 12 participants showed shorter paretic step length. For the hemiparesis group, linear regression analysis showed that ATP asymmetry, AFP asymmetry, and TP patterns had significant predictability regarding step length asymmetry. Prolonged paretic ATP and shortened paretic AFP was the predominant pattern in the hemiparesis group, even in participants with symmetric step length. However, some participants showed same direction of ATP and AFP asymmetry. These findings indicate the following: (1) ATP asymmetries should be observed to determine individual characteristics of step length asymmetry, and (2) TP patterns can provide complementary information for non-paretic limb compensation. Copyright © 2016 Elsevier B.V. All rights reserved.
DefenseLink.mil - Special Report - 35 Years of Volunteer Forces - July 1,
force, when many in the military were convinced the system would fail. Yet after the volunteer military volunteer service Our nation is fortunate that so many talented and patriotic young people have stepped Photo of Gen. George W. Casey Jr. When Gen. George W. Casey Jr. became chief of staff of the Army in
topHeader GSFC NASA SwRI Denver Museum of Nature and Science sub header Home Science and the ready to go back to the Moon? NASA took the first step in that direction in 2009 with the launch of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Don, S; Cormack, R; Viswanathan, A
Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The systemmore » consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.« less
Compliant walking appears metabolically advantageous at extreme step lengths.
Kim, Jaehoon; Bertram, John E A
2018-05-19
Humans alter gait in response to unusual gait circumstances to accomplish the task of walking. For instance, subjects spontaneously increase leg compliance at a step length threshold as step length increases. Here we test the hypothesis that this transition occurs based on the level of energy expenditure, where compliant walking becomes less energetically demanding at long step lengths. To map and compare the metabolic cost of normal and compliant walking as step length increases. 10 healthy individuals walked on a treadmill using progressively increasing step lengths (100%, 120%, 140% and 160% of preferred step length), in both normal and compliant leg walking as energy expenditure was recorded via indirect calorimetry. Leg compliance was controlled by lowering the center-of-mass trajectory during stance, forcing the leg to flex and extend as the body moved over the foot contact. For normal step lengths, compliant leg walking was more costly than normal walking gait, but compliant leg walking energetic cost did not increase as rapidly for longer step lengths. This led to an intersection between normal and compliant walking cost curves at 114% relative step length (regression analysis; r 2 = 0.92 for normal walking; r 2 = 0.65 for compliant walking). Compliant leg walking is less energetically demanding at longer step lengths where a spontaneous shift to compliant walking has been observed, suggesting the human motor control system is sensitive to energetic requirements and will employ alternate movement patterns if advantageous strategies are available. The transition could be attributed to the interplay between (i) leg work controlling body travel during single stance and (ii) leg work to control energy loss in the step-to-step transition. Compliant leg walking requires more stance leg work at normal step lengths, but involves less energy loss at the step-to-step transition for very long steps. Copyright © 2018 Elsevier B.V. All rights reserved.
Dave Moore: Taking Roundabout Path to Perovskite Fast Track | News | NREL
energy of academia is awesome and contagious. It keeps you young to hang around young people and keep learning." Although he'd had a checkered high school academic career prior to stepping on the college ," Moore said. "That's where I first learned about the energy crisis." And that's when he
NAM - Eta to NMM conversion 20060613
North American Mesoscale (NAM) time slot. Currently the the Eta forecast model is used for the NAM, but Eta and its output will be available at the same time. There will be some minor addition of products MB per file (time step). - The following fields will be added: - omega @ 10, 20, & 30 mb - height
NREL's CelA Catalyzes Plant Cell Walls Faster | News | NREL
12, 2015 Close-up photo of a scientist in safety glasses examining small items in plastic containers because high temperatures mean faster action. Also, because it can operate above the boiling point of alcohol, the alcohol is separated naturally, saving a costly step in the conversion process-and the high
Research Team Engineers a Better Plastic-Degrading Enzyme | News | NREL
polyethylene terephthalate, or PET. While working to solve the crystal structure of PETase-a recently determine its structure to aid in protein engineering, but we ended up going a step further and accidentally discovery that PETase can also degrade polyethylene furandicarboxylate, or PEF, a bio-based substitute for
Alternative Fuels Data Center: Vehicle Search
Compare (up to 5) About The Data Refine Your Search Fuel/Technology White plus All Fuels Biodiesel (B20 - LNG Hybrid Class/Type White plus All Classes/Types Sedan/Wagon Truck SUV Van Step Van Vocational/Cab -Duty White plus All Manufacturers Acura Audi BMW BYD Motors Buick Cadillac Chevrolet Chrysler Dodge
Defense.gov - Special Report - Toby Keith's USO Tour
FOB hopping around central Afghanistan. When you are put together with a group of people 24 hours a at an all time high. Not since my early trips to Iraq, have we been escorted in by gunships as often surprised to find when we stepped off the plane that the landscape was almost the same as the one we had
Setting Up Git Software Tool on Linux | High-Performance Computing | NREL
system. Before you can get started using the github.nrel.gov git repos, you'll have to do some basic shell (SSH) keys created on those systems. If this is the case, for more information, see using the git Steps - Using a Remote Git Repository Now you have all the basic configuration for using git with a
ACHP | The United Nations Declaration on the Rights of Indigenous Peoples
March 1, 2013, the ACHP took a bold step to adopt a plan to support the U.N. Declaration. One of the commitments in the plan is to inform the historic preservation community about the Declaration. Therefore, we announcing ACHP plan to support the Declaration ACHP Plan to Support the U.N. Declaration on the Rights of
Maximum step length: relationships to age and knee and hip extensor capacities.
Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B
2007-07-01
Maximum Step Length may be used to identify older adults at increased risk for falls. Since leg muscle weakness is a risk factor for falls, we tested the hypotheses that maximum knee and hip extension speed, strength, and power capacities would significantly correlate with Maximum Step Length and also that the "step out and back" Maximum Step Length [Medell, J.L., Alexander, N.B., 2000. A clinical measure of maximal and rapid stepping in older women. J. Gerontol. A Biol. Sci. Med. Sci. 55, M429-M433.] would also correlate with the Maximum Step Length of its two sub-tasks: stepping "out only" and stepping "back only". These sub-tasks will be referred to as versions of Maximum Step Length. Unimpaired younger (N=11, age=24[3]years) and older (N=10, age=73[5]years) women performed the above three versions of Maximum Step Length. Knee and hip extension speed, strength, and power capacities were determined on a separate day and regressed on Maximum Step Length and age group. Version and practice effects were quantified and subjective impressions of test difficulty recorded. Hypotheses were tested using linear regressions, analysis of variance, and Fisher's exact test. Maximum Step Length explained 6-22% additional variance in knee and hip extension speed, strength, and power capacities after controlling for age group. Within- and between-block and test-retest correlation values were high (>0.9) for all test versions. Shorter Maximum Step Lengths are associated with reduced knee and hip extension speed, strength, and power capacities after controlling for age. A single out-and-back step of maximal length is a feasible, rapid screening measure that may provide insight into underlying functional impairment, regardless of age.
World-Record Solar Cell a Step Closer to Cheap Solar Energy
envelope of solar-cell efficiency, we can begin to visualize the day when energy from the sun will be in efficiency translates into lower costs for harnessing energy from the sun. The cell's excellent
NREL and CSEM Jointly Set New Efficiency Record with Dual-Junction Solar
converting non-concentrated (1-sun) sunlight into electricity using a dual-junction III-V/Si solar cell. The 29.8 percent one-sun efficiency," which details the steps taken to break the previous record. His
Energy Systems Integration News | Energy Systems Integration Facility |
facility. "We try to scope out some technical work that is based on the fundamental problem that technical or market problem that they're trying to solve, and then we'll scope out work with them based on that visit. "The second step is to begin to break that scope of work into what I call three
Paint it Black: One-Step Etch Cuts Solar Cell Costs - Continuum Magazine
quicker, cheaper way to produce large volumes of high-performance PV devices. Cost is a major obstacle for propel PV toward cost-competitiveness. A New Approach to Antireflection Any light reflected from a solar etching large pyramids into the cell surface, add considerable cost to a solar cell-and they succeed only
Peregrine Transition from CentOS6 to CentOS7 | High-Performance Computing |
). Users should consider them primarily as examples, which they can copy and modify for their own use with HPC environments. This can permit one-step access to pre-existing complex software stacks, or /projects. This is not a highly suggested mechanism, but might serve for one-time needs. In the unlikely
ACHP | Working Together to Build a More Inclusive Preservation Program
LaRue, history educator, Washington Court House, Ohio Paul LaRue Paul LaRue retired in 2014 after 30 about their own history and that of their community and getting actively involved in historic history; which gave my students the opportunity to step out of the classroom and into the community to
Making a Computer Model of the Most Complex System Ever Built - Continuum
Eastern Interconnection, all as a function of time. All told, that's about 1,000 gigabytes of data the modeling software steps forward in time, those decisions affect how the grid operates under Interconnection at five-minute intervals for one year would have required more than 400 days of computing time
NREL's Newest Partnership Tool Increases Flexibility - Continuum Magazine
, five-year agreement at NREL's annual Industry Growth Forum, taking the next step in a growing energy investment forum. As such, it is the ideal venue to highlight a novel $10 million, five-year will focus on five to 10 companies, ranging from Tier I to III stages, and make awards of $50,000 to
Linking pedestrian flow characteristics with stepping locomotion
NASA Astrophysics Data System (ADS)
Wang, Jiayue; Boltes, Maik; Seyfried, Armin; Zhang, Jun; Ziemer, Verena; Weng, Wenguo
2018-06-01
While properties of human traffic flow are described by speed, density and flow, the locomotion of pedestrian is based on steps. To relate characteristics of human locomotor system with properties of human traffic flow, this paper aims to connect gait characteristics like step length, step frequency, swaying amplitude and synchronization with speed and density and thus to build a ground for advanced pedestrian models. For this aim, observational and experimental study on the single-file movement of pedestrians at different densities is conducted. Methods to measure step length, step frequency, swaying amplitude and step synchronization are proposed by means of trajectories of the head. Mathematical models for the relations of step length or frequency and speed are evaluated. The problem how step length and step duration are influenced by factors like body height and density is investigated. It is shown that the effect of body height on step length and step duration changes with density. Furthermore, two different types of step in-phase synchronization between two successive pedestrians are observed and the influence of step synchronization on step length is examined.
Trends in NRMP Data from 2007-2014 for U.S. Seniors Matching into Emergency Medicine.
Manthey, David E; Hartman, Nicholas D; Newmyer, Aileen; Gunalda, Jonah C; Hiestand, Brian C; Askew, Kim L; Lefebvre, Cedric
2017-01-01
Since 1978, the National Residency Matching Program (NRMP) has published data demonstrating characteristics of applicants who have matched into their preferred specialty in the NRMP main residency match. These data have been published approximately every two years. There is limited information about trends within these published data for students matching into emergency medicine (EM). Our objective was to investigate and describe trends in NRMP data to include the following: the ratio of applicants to available EM positions; United State Medical Licensing Examination (USMLE) Step 1 and Step 2 scores (compared to the national means); number of programs ranked; and Alpha Omega Alpha Honor Medical Society (AOA) membership among U.S. seniors matching into EM. This was a retrospective observational review of NRMP data published between 2007 and 2016. We analyzed the data using analysis of variance (ANOVA) or Kruskal-Wallis testing, and Fischer's exact or chi-squared testing, as appropriate to determine statistical significance. The ratio of applicants to available EM positions remained essentially stable from 2007 to 2014 but did increase slightly in 2016. We observed a net upward trend in overall Step 1 and Step 2 scores for EM applicants. However, this did not outpace the national trend increase in Step 1 and 2 scores overall. There was an increase in the mean number of programs ranked by EM applicants over the years studied from 7.8 (SD4.2) to 9.2 (SD5.0, p<0.001), driven predominantly by the cohort of U.S. students successful in the match. Among time intervals, there was a difference in the number of EM applicants with AOA membership (p=0.043) due to a drop in the number of AOA students in 2011. No sustained statistical trend in AOA membership was identified over the seven-year period studied. NRMP data demonstrate trends among EM applicants that are similar to national trends in other specialties for USMLE board scores, and a modest increase in number of programs ranked. AOA membership was largely stable. EM does not appear to have become more competitive relative to other specialties or previous years in these categories.
Effects of step length and step frequency on lower-limb muscle function in human gait.
Lim, Yoong Ping; Lin, Yi-Chung; Pandy, Marcus G
2017-05-24
The aim of this study was to quantify the effects of step length and step frequency on lower-limb muscle function in walking. Three-dimensional gait data were used in conjunction with musculoskeletal modeling techniques to evaluate muscle function over a range of walking speeds using prescribed combinations of step length and step frequency. The body was modeled as a 10-segment, 21-degree-of-freedom skeleton actuated by 54 muscle-tendon units. Lower-limb muscle forces were calculated using inverse dynamics and static optimization. We found that five muscles - GMAX, GMED, VAS, GAS, and SOL - dominated vertical support and forward progression independent of changes made to either step length or step frequency, and that, overall, changes in step length had a greater influence on lower-limb joint motion, net joint moments and muscle function than step frequency. Peak forces developed by the uniarticular hip and knee extensors, as well as the normalized fiber lengths at which these muscles developed their peak forces, correlated more closely with changes in step length than step frequency. Increasing step length resulted in larger contributions from the hip and knee extensors and smaller contributions from gravitational forces (limb posture) to vertical support. These results provide insight into why older people with weak hip and knee extensors walk more slowly by reducing step length rather than step frequency and also help to identify the key muscle groups that ought to be targeted in exercise programs designed to improve gait biomechanics in older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.
Schulz, Brian W.; Jongprasithporn, Manutchanok; Hart-Hughes, Stephanie J.; Bulat, Tatjana
2017-01-01
Background Maximum step length is a brief clinical test involving stepping out and back as far as possible with the arms folded across the chest. This test has been shown to predict fall risk, but the biomechanics of this test are not fully understood. Knee and hip kinetics (moments and powers) are greater for longer steps and for younger subjects, but younger subjects also step farther. Methods To separate effects of step length, age, and fall history on joint kinetics; 14 healthy younger, 14 older non-fallers, and 11 older fallers (27(5), 72(5), 75(6) years respectively) all stepped to the same relative target distances of 20-80% of their height. Knee and hip kinetics and knee co-contraction were calculated. Findings Hip and knee kinetics and knee co-contraction all increased with step length, but older non-fallers and fallers utilized greater stepping hip and less stepping knee extensor kinetics. Fallers had greater stepping knee co-contraction than non-fallers. Stance knee co-contraction of non-fallers was similar to young for shorter steps and similar to fallers for longer steps. Interpretation Age had minimal effects and fall history had no effects on joint kinetics of steps to similar distances. Effects of age and fall history on knee co-contraction may contribute to age-related kinetic differences and shorter maximal step lengths of older non-fallers and fallers, but step length correlated with every variable tested. Thus, declines in maximum step length could indicate declines in hip and knee extensor kinetics and impaired performance on similar tasks like recovering from a trip. PMID:23978310
Savin, Douglas N.; Morton, Susanne M.; Whitall, Jill
2013-01-01
Objectives Determine whether adaptation to a swing phase perturbation during gait transferred from treadmill to overground walking, the rate of overground deadaptation, and whether overground aftereffects improved step length asymmetry in persons with hemiparetic stroke and gait asymmetry. Methods Ten participants with stroke and hemiparesis and 10 controls walked overground on an instrumented gait mat, adapted gait to a swing phase perturbation on a treadmill, then walked overground on the gait mat again. Outcome measures, primary: overground step length symmetry, rates of treadmill step length symmetry adaptation and overground step length symmetry deadaptation; secondary: overground gait velocity, stride length, and stride cycle duration. Results Step length symmetry aftereffects generalized to overground walking and adapted at a similar rate on the treadmill in both groups. Aftereffects decayed at a slower rate overground in participants with stroke and temporarily improved overground step length asymmetry. Both groups’ overground gait velocity increased post adaptation due to increased stride length and decreased stride duration. Conclusions Stroke and hemiparesis do not impair generalization of step length symmetry changes from adapted treadmill to overground walking, but prolong overground aftereffects. Significance Motor adaptation during treadmill walking may be an effective treatment for improving overground gait asymmetries post-stroke. PMID:24286858
The effects of age and step length on joint kinematics and kinetics of large out-and-back steps.
Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B
2008-06-01
Maximum step length (MSL) is a clinical test that has been shown to correlate with age, various measures of fall risk, and knee and hip joint extension speed, strength, and power capacities, but little is known about the kinematics and kinetics of the large out-and-back step utilized. Body motions and ground reaction forces were recorded for 11 unimpaired younger and 10 older women while attaining maximum step length. Joint kinematics and kinetics were calculated using inverse dynamics. The effects of age group and step length on the biomechanics of these large out-and-back steps were determined. Maximum step length was 40% greater in the younger than in the older women (P<0.0001). Peak knee and hip, but not ankle, angle, velocity, moment, and power were generally greater for younger women and longer steps. After controlling for age group, step length generally explained significant additional variance in hip and torso kinematics and kinetics (incremental R2=0.09-0.37). The young reached their peak knee extension moment immediately after landing of the step out, while the old reached their peak knee extension moment just before the return step liftoff (P=0.03). Maximum step length is strongly associated with hip kinematics and kinetics. Delays in peak knee extension moment that appear to be unrelated to step length, may indicate a reduced ability of older women to rapidly apply force to the ground with the stepping leg and thus arrest the momentum of a fall.
The effects of age and step length on joint kinematics and kinetics of large out-and-back steps
Schulz, Brian W.; Ashton-Miller, James A.; Alexander, Neil B.
2008-01-01
Background Maximum Step Length is a clinical test that has been shown to correlate with age, various measures of fall risk, and knee and hip joint extension speed, strength, and power capacities, but little is known about the kinematics and kinetics of the large out-and-back step utilized. Methods Body motions and ground reaction forces were recorded for 11 unimpaired younger and 10 older women while attaining Maximum Step Length. Joint kinematics and kinetics were calculated using inverse dynamics. The effects of age group and step length on the biomechanics of these large out-and-back steps were determined. Findings Maximum Step Length was 40% greater in the younger than in the older women (p<0.0001). Peak knee and hip, but not ankle, angle, velocity, moment, and power were generally greater for younger women and longer steps. After controlling for age group, step length generally explained significant additional variance in hip and torso kinematics and kinetics (incremental R2=0.09–0.37). The young reached their peak knee extension moment immediately after landing of the step out, while the old reached their peak knee extension moment just before the return step lift off (p=0.03). Interpretation Maximum Step Length is strongly associated with hip kinematics and kinetics. Delays in peak knee extension moment that appear to be unrelated to step length, may indicate a reduced ability of older women to rapidly apply force to the ground with the stepping leg and thus arrest the momentum of a fall. PMID:18308435
The use of emergency manuals in perioperative crisis management: a cautious approach.
Szabo, Ashley; August, David A; Klainer, Suzanne; Miller, Andrew D; Kaye, Alan D; Raemer, Daniel B; Urman, Richard D
2015-01-01
When an unexpected perioperative crisis arises, simulation studies have suggested that the use of an emergency manual (EM) may offset the large cognitive load involved in crisis management, facilitating the efficient performance of key steps in treatment. However, little is known about how well EMs will translate into actual practice and what is required to use them optimally. While EMs are a promising tool in the management of perioperative critical events, more research is needed to define best practices and their limitations. In the interim, cautious use of these cognitive aids is recommended, especially when the diagnosis is not straightforward, falls "in between" sections of the EM, or falls outside of the EM itself. Further research should focus on the efficacy of EMs as measured by the percentage of critical steps correctly performed by their users in scenarios that do not closely mirror one of the listed EM scenarios from the beginning or as the situation evolves.
Meyers, Robert W; Oliver, Jon L; Hughes, Michael G; Lloyd, Rhodri S; Cronin, John B
2017-04-01
Meyers, RW, Oliver, JL, Hughes, MG, Lloyd, RS, and Cronin, JB. Influence of age, maturity, and body size on the spatiotemporal determinants of maximal sprint speed in boys. J Strength Cond Res 31(4): 1009-1016, 2017-The aim of this study was to investigate the influence of age, maturity, and body size on the spatiotemporal determinants of maximal sprint speed in boys. Three-hundred and seventy-five boys (age: 13.0 ± 1.3 years) completed a 30-m sprint test, during which maximal speed, step length, step frequency, contact time, and flight time were recorded using an optical measurement system. Body mass, height, leg length, and a maturity offset represented somatic variables. Step frequency accounted for the highest proportion of variance in speed (∼58%) in the pre-peak height velocity (pre-PHV) group, whereas step length explained the majority of the variance in speed (∼54%) in the post-PHV group. In the pre-PHV group, mass was negatively related to speed, step length, step frequency, and contact time; however, measures of stature had a positive influence on speed and step length yet a negative influence on step frequency. Speed and step length were also negatively influence by mass in the post-PHV group, whereas leg length continued to positively influence step length. The results highlighted that pre-PHV boys may be deemed step frequency reliant, whereas those post-PHV boys may be marginally step length reliant. Furthermore, the negative influence of body mass, both pre-PHV and post-PHV, suggests that training to optimize sprint performance in youth should include methods such as plyometric and strength training, where a high neuromuscular focus and the development force production relative to body weight are key foci.
Liang, Bo Wei; Wu, Wen Hua; Meijer, Onno G; Lin, Jian Hua; Lv, Go Rong; Lin, Xiao Cong; Prins, Maarten R; Hu, Hai; van Dieën, Jaap H; Bruijn, Sjoerd M
2014-01-01
Transverse plane pelvis rotations during walking may be regarded as the "first determinant of gait". This would assume that pelvis rotations increase step length, and thereby reduce the vertical movements of the centre of mass-"the pelvic step". We analysed the pelvic step using 20 healthy young male subjects, walking on a treadmill at 1-5 km/h, with normal or big steps. Step length, pelvis rotation amplitude, leg-pelvis relative phase, and the contribution of pelvis rotation to step length were calculated. When speed increased in normal walking, pelvis rotation changed from more out-of-phase to in-phase with the upper leg. Consequently, the contribution of pelvis rotation to step length was negative at lower speeds, switching to positive at 3 km/h. With big steps, leg and pelvis were more in-phase, and the contribution of pelvis rotation to step length was always positive, and relatively large. Still, the overall contribution of pelvis rotations to step length was small, less than 3%. Regression analysis revealed that leg-pelvis relative phase predicted about 60% of the variance of this contribution. The results of the present study suggest that, during normal slow walking, pelvis rotations increase, rather than decrease, the vertical movements of the centre of mass. With large steps, this does not happen, because leg and pelvis are in-phase at all speeds. Finally, it has been suggested that patients with hip flexion limitation may use larger pelvis rotations to increase step length. This, however, may only work as long as the pelvis rotates in-phase with the leg. Copyright © 2013 Elsevier B.V. All rights reserved.
Step 2: Enter Baseline Energy Consumption Data | Climate Action Planning
Scope 1: Emissions (Direct Combustion) T CO2e = Tonnes of Carbon Dioxide Equivalent* Gas (T CO2e) Oil (T CO2e) Coal (T CO2e) Fleet (T CO2e) Total (T CO2e) *Metric tons of CO2 equivalent or 2.204 lbs of CO2
Step styles of pedestrians at different densities
NASA Astrophysics Data System (ADS)
Wang, Jiayue; Weng, Wenguo; Boltes, Maik; Zhang, Jun; Tordeux, Antoine; Ziemer, Verena
2018-02-01
Stepping locomotion is the basis of human movement. The investigation of stepping locomotion and its affecting factors is necessary for a more realistic knowledge of human movement, which is usually referred to as walking with equal step lengths for the right and left leg. To study pedestrians’ stepping locomotion, a set of single-file movement experiments involving 39 participants of the same age walking on a highly curved oval course is conducted. The microscopic characteristics of the pedestrians including 1D Voronoi density, speed, and step length are calculated based on a projected coordinate. The influence of the projection lines with different radii on the measurement of these quantities is investigated. The step lengths from the straight and curved parts are compared using the Kolmogorov-Smirnov test. During the experiments, six different step styles are observed and the proportions of different step styles change with the density. At low density, the main step style is the stable-large step style and the step lengths of one pedestrian are almost constant. At high density, some pedestrians adjust and decrease their step lengths. Some pedestrians take relatively smaller and larger steps alternately to adapt to limited space.
Estimating loop length from CryoEM images at medium resolutions.
McKnight, Andrew; Si, Dong; Al Nasr, Kamal; Chernikov, Andrey; Chrisochoides, Nikos; He, Jing
2013-01-01
De novo protein modeling approaches utilize 3-dimensional (3D) images derived from electron cryomicroscopy (CryoEM) experiments. The skeleton connecting two secondary structures such as α-helices represent the loop in the 3D image. The accuracy of the skeleton and of the detected secondary structures are critical in De novo modeling. It is important to measure the length along the skeleton accurately since the length can be used as a constraint in modeling the protein. We have developed a novel computational geometric approach to derive a simplified curve in order to estimate the loop length along the skeleton. The method was tested using fifty simulated density images of helix-loop-helix segments of atomic structures and eighteen experimentally derived density data from Electron Microscopy Data Bank (EMDB). The test using simulated density maps shows that it is possible to estimate within 0.5 Å of the expected length for 48 of the 50 cases. The experiments, involving eighteen experimentally derived CryoEM images, show that twelve cases have error within 2 Å. The tests using both simulated and experimentally derived images show that it is possible for our proposed method to estimate the loop length along the skeleton if the secondary structure elements, such as α-helices, can be detected accurately, and there is a continuous skeleton linking the α-helices.
Independent influence of gait speed and step length on stability and fall risk.
Espy, D D; Yang, F; Bhatt, T; Pai, Y-C
2010-07-01
With aging, individuals' gaits become slower and their steps shorter; both are thought to improve stability against balance threats. Recent studies have shown that shorter step lengths, which bring the center of mass (COM) closer to the leading foot, improve stability against slip-related falls. However, a slower gait, hence lower COM velocity, does the opposite. Due to the inherent coupling of step length and speed in spontaneous gait, the extent to which the benefit of shorter steps can offset the slower speed is unknown. The purpose of this study was to investigate, through decoupling, the independent effects of gait speed and step length on gait stability and the likelihood of slip-induced falls. Fifty-seven young adults walked at one of three target gait patterns, two of equal speed and two of equal step length; at a later trial, they encountered an unannounced slip. The results supported our hypotheses that faster gait as well as shorter steps each ameliorates fall risk when a slip is encountered. This appeared to be attributable to the maintenance of stability from slip initiation to liftoff of the recovery foot during the slip. Successful decoupling of gait speed from step length reveals for the first time that, although slow gait in itself leads to instability and falls (a one-standard-deviation decrease in gait speed increases the odds of fall by 4-fold), this effect is offset by the related decrease in step length (the same one-standard-deviation decrease in step length lowers fall risk by 6 times). Copyright © 2010 Elsevier B.V. All rights reserved.
Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D
2017-10-01
The purpose of this study was to examine the effects of step length and foot strike pattern along with their interaction on tibiofemoral joint (TFJ) and medial compartment TFJ kinetics during running. Nineteen participants ran with a rear foot strike pattern at their preferred speed using a short (-10%), preferred, and long (+10%) step length. These step length conditions were then repeated using a forefoot strike pattern. Regardless of foot strike pattern, a 10% shorter step length resulted in decreased peak contact force, force impulse per step, force impulse per kilometre, and average loading rate at the TFJ and medial compartment, while a 10% increased step length had the opposite effects (all P < 0.05). A forefoot strike pattern significantly lowered TFJ and medial compartment TFJ average loading rates compared with a rear foot strike pattern (both <0.05) but did not change TFJ or medial compartment peak force, force impulse per step, or force impulse per km. The combination of a shorter step length and forefoot strike pattern produced the greatest reduction in peak medial compartment contact force (P < 0.05). Knowledge of these running modification effects may be relevant to the management or prevention of TFJ injury or pathology among runners.
Jackson, Ryan N.; McCoy, Airlie J.; Terwilliger, Thomas C.; ...
2015-07-30
Structures of multi-subunit macromolecular machines are primarily determined by either electron microscopy (EM) or X-ray crystallography. In many cases, a structure for a complex can be obtained at low resolution (at a coarse level of detail) with EM and at higher resolution (with finer detail) by X-ray crystallography. The integration of these two structural techniques is becoming increasingly important for generating atomic models of macromolecular complexes. A low-resolution EM image can be a powerful tool for obtaining the "phase" information that is missing from an X-ray crystallography experiment, however integration of EM and X-ray diffraction data has been technically challenging.more » Here we show a step-by-step protocol that explains how low-resolution EM maps can be placed in the crystallographic unit cell by molecular replacement, and how initial phases computed from the placed EM density are extended to high resolution by averaging maps over non-crystallographic symmetry. As the resolution gap between EM and Xray crystallography continues to narrow, the use of EM maps to help with X-ray crystal structure determination, as described in this protocol, will become increasingly effective.« less
Zeil, Stephanie; Kovacs, Julio; Wriggers, Willy; He, Jing
2017-01-01
Three-dimensional density maps of biological specimens from cryo-electron microscopy (cryo-EM) can be interpreted in the form of atomic models that are modeled into the density, or they can be compared to known atomic structures. When the central axis of a helix is detectable in a cryo-EM density map, it is possible to quantify the agreement between this central axis and a central axis calculated from the atomic model or structure. We propose a novel arc-length association method to compare the two axes reliably. This method was applied to 79 helices in simulated density maps and six case studies using cryo-EM maps at 6.4-7.7 Å resolution. The arc-length association method is then compared to three existing measures that evaluate the separation of two helical axes: a two-way distance between point sets, the length difference between two axes, and the individual amino acid detection accuracy. The results show that our proposed method sensitively distinguishes lateral and longitudinal discrepancies between the two axes, which makes the method particularly suitable for the systematic investigation of cryo-EM map-model pairs.
Zeil, Stephanie; Kovacs, Julio; Wriggers, Willy
2017-01-01
Abstract Three-dimensional density maps of biological specimens from cryo-electron microscopy (cryo-EM) can be interpreted in the form of atomic models that are modeled into the density, or they can be compared to known atomic structures. When the central axis of a helix is detectable in a cryo-EM density map, it is possible to quantify the agreement between this central axis and a central axis calculated from the atomic model or structure. We propose a novel arc-length association method to compare the two axes reliably. This method was applied to 79 helices in simulated density maps and six case studies using cryo-EM maps at 6.4–7.7 Å resolution. The arc-length association method is then compared to three existing measures that evaluate the separation of two helical axes: a two-way distance between point sets, the length difference between two axes, and the individual amino acid detection accuracy. The results show that our proposed method sensitively distinguishes lateral and longitudinal discrepancies between the two axes, which makes the method particularly suitable for the systematic investigation of cryo-EM map–model pairs. PMID:27936925
Trends in National Emergency Medicine Conference Didactic Lectures Over a 6-Year Period.
Gottlieb, Michael; Riddell, Jeff; Njie, Abdoulie
2017-01-01
National conference didactic lectures have traditionally featured hour-long lecture-based presentations. However, there is evidence that longer lectures can lead to both decreased attention and retention of information. The authors sought to identify trends in lecture duration, lecture types, and number of speakers at four national emergency medicine (EM) conferences over a 6-year period. The authors performed a retrospective analysis of the length, number of speakers, and format of didactic lectures at four different national EM conferences over 6 years. The authors abstracted data from the national academic assemblies for the four largest not-for-profit EM organizations in the United States: American Academy of Emergency Medicine, American College of Emergency Physicians, Council of Emergency Medicine Residency Directors, and Society for Academic Emergency Medicine. There was a significant yearly decrease in the mean lecture lengths for three of the four conferences. There was an increase in the percentage of rapid fire sessions over the preceding 2 years with a corresponding decrease in the percentage of general educational sessions. There was no significant difference in the mean number of speakers per lecture. An analysis of 4210 didactic lecture sessions from the annual meetings of four national EM organizations over a 6-year period showed significant decreases in mean lecture length. These findings can help to guide EM continuing medical education conference planning and research.
Two Independent Contributions to Step Variability during Over-Ground Human Walking
Collins, Steven H.; Kuo, Arthur D.
2013-01-01
Human walking exhibits small variations in both step length and step width, some of which may be related to active balance control. Lateral balance is thought to require integrative sensorimotor control through adjustment of step width rather than length, contributing to greater variability in step width. Here we propose that step length variations are largely explained by the typical human preference for step length to increase with walking speed, which itself normally exhibits some slow and spontaneous fluctuation. In contrast, step width variations should have little relation to speed if they are produced more for lateral balance. As a test, we examined hundreds of overground walking steps by healthy young adults (N = 14, age < 40 yrs.). We found that slow fluctuations in self-selected walking speed (2.3% coefficient of variation) could explain most of the variance in step length (59%, P < 0.01). The residual variability not explained by speed was small (1.5% coefficient of variation), suggesting that step length is actually quite precise if not for the slow speed fluctuations. Step width varied over faster time scales and was independent of speed fluctuations, with variance 4.3 times greater than that for step length (P < 0.01) after accounting for the speed effect. That difference was further magnified by walking with eyes closed, which appears detrimental to control of lateral balance. Humans appear to modulate fore-aft foot placement in precise accordance with slow fluctuations in walking speed, whereas the variability of lateral foot placement appears more closely related to balance. Step variability is separable in both direction and time scale into balance- and speed-related components. The separation of factors not related to balance may reveal which aspects of walking are most critical for the nervous system to control. PMID:24015308
NASA Astrophysics Data System (ADS)
Zeng, Guang; Cao, Shuchao; Liu, Chi; Song, Weiguo
2018-06-01
It is important to study pedestrian stepping behavior and characteristics for facility design and pedestrian flow study due to pedestrians' bipedal movement. In this paper, data of steps are extracted based on trajectories of pedestrians from a single-file experiment. It is found that step length and step frequency will decrease 75% and 33%, respectively, when global density increases from 0.46 ped/m to 2.28 ped/m. With the increment of headway, they will first increase and then remain constant when the headway is beyond 1.16 m and 0.91 m, respectively. Step length and frequency under different headways can be described well by normal distributions. Meanwhile, relationships between step length and frequency under different headways exist. Step frequency decreases with the increment of step length. However, the decrease tendencies depend on headways as a whole. And there are two decrease tendencies: when the headway is between about 0.6 m and 1.0 m, the decrease rate of the step frequency will increase with the increment of step length; while it will decrease when the headway is beyond about 1.0 m and below about 0.6 m. A model is built based on the experiment results. In fundamental diagrams, the results of simulation agree well with those of experiment. The study can be helpful for understanding pedestrian stepping behavior and designing public facilities.
NASA Astrophysics Data System (ADS)
Aylor, Donald E.; Boehm, Matthew T.; Shields, Elson J.
2006-07-01
The extensive adoption of genetically modified crops has led to a need to understand better the dispersal of pollen in the atmosphere because of the potential for unwanted movement of genetic traits via pollen flow in the environment. The aerial dispersal of maize pollen was studied by comparing the results of a Lagrangian stochastic (LS) model with pollen concentration measurements made over cornfields using a combination of tower-based rotorod samplers and airborne radio-controlled remote-piloted vehicles (RPVs) outfitted with remotely operated pollen samplers. The comparison between model and measurements was conducted in two steps. In the first step, the LS model was used in combination with the rotorod samplers to estimate the pollen release rate Q for each sampling period. In the second step, a modeled value for the concentration Cmodel, corresponding to each RPV measured value Cmeasure, was calculated by simulating the RPV flight path through the LS model pollen plume corresponding to the atmospheric conditions, field geometry, wind direction, and source strength. The geometric mean and geometric standard deviation of the ratio Cmodel/Cmeasure over all of the sampling periods, except those determined to be upwind of the field, were 1.42 and 4.53, respectively, and the lognormal distribution corresponding to these values was found to fit closely the PDF of Cmodel/Cmeasure. Model output was sensitive to the turbulence parameters, with a factor-of-100 difference in the average value of Cmodel over the range of values encountered during the experiment. In comparison with this large potential variability, it is concluded that the average factor of 1.4 between Cmodel and Cmeasure found here indicates that the LS model is capable of accurately predicting, on average, concentrations over a range of atmospheric conditions.
Milner, Clare E; Meardon, Stacey A; Hawkins, Jillian L; Willson, John D
2018-04-28
Knee osteoarthritis is a major public health problem and adults with obesity are particularly at risk. One approach to alleviating this problem is to reduce the mechanical load at the joint during daily activity. Adjusting temporospatial parameters of walking could mitigate cumulative knee joint mechanical loads. The purpose of this study was to determine how adjustments to velocity and step length affects knee joint loading in healthy weight adults and adults with obesity. We collected three-dimensional gait analysis data on 10 adults with a normal body mass index and 10 adults with obesity during over ground walking in nine different conditions. In addition to preferred velocity and step length, we also conducted combinations of 15% increased and decreased velocity and step length. Peak tibiofemoral joint impulse and knee adduction angular impulse were reduced in the decreased step length conditions in both healthy weight adults (main effect) and those with obesity (interaction effect). Peak knee joint adduction moment was also reduced with decreased step length, and with decreased velocity in both groups. We conclude from these results that adopting shorter step lengths during daily activity and when walking for exercise can reduce mechanical stimuli associated with articular cartilage degenerative processes in adults with and without obesity. Thus, walking with reduced step length may benefit adults at risk for disability due to knee osteoarthritis. Adopting a shorter step length during daily walking activity may reduce knee joint loading and thus benefit those at risk for knee cartilage degeneration. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:XX-XX, 2018. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Steeplechase barriers affect women less than men.
Hunter, Iain; Bushnell, Tyler D
2006-01-01
Women began contesting the 3000 m steeplechase during the 1990's using barriers of different dimensions than men. Whenever a new event is introduced for women, consideration should be taken as to whether different technique or training methods should be utilized. This study investigated three aspects of hurdling technique: 1) Differences in the ratio of the landing step to the penultimate step between men and women around each non-water jump steeplechase barrier, 2) differences in step lengths between the four non-water jump barriers, and 3) changes in the step lengths around the barrier throughout the race. The step lengths around the 28 non-water jump barriers of the top seven men and women at the 2003 USA Track and Field Championships were measured using a two-dimensional analysis. A t-test determined any differences between men and women for the ratio of the landing to penultimate steps. A 2x4 repeated measures ANOVA tested for differences between the four non-water jump barriers. Linear regression tested for changes in step lengths throughout the race. Men exhibited a smaller ratio between the lengths of the landing to penultimate steps than women (0.73 ± 0.09 and 0.77 ± 0.10 for men and women respectively, p = 0.002). No step length differences were observed between the four barriers in the step lengths around each barrier (p = 0.192 and p = 0.105 for men and women respectively). Athletes gradually increased the total length of all steps around the barriers throughout the race (R(2) = 0.021, p = 0.048 and R(2) = 0.137, p < 0.001 for men and women respectively). The smaller ratio between landing to penultimate steps shows that the barriers affect women less than men. There may be a need to train men and women differently for the non-water jump barriers in the steeplechase or slightly alter racing strategy. Key PointsNon-water jump barriers disrupt the stride of men more than women.There is no difference between any of the four non-water jump barriers in the step lengths used around each barrier.Stride length gradually increases throughout a 3000m steeplechase race even if race pace is maintain.
Gait Coordination in Parkinson Disease: Effects of Step Length and Cadence Manipulations
Williams, April J.; Peterson, Daniel S.; Earhart, Gammon M.
2013-01-01
Background Gait impairments are well documented in those with PD. Prior studies suggest that gait impairments may be worse and ongoing in those with PD who demonstrate FOG compared to those with PD who do not. Purpose Our aim was to determine the effects of manipulating step length and cadence individually, and together, on gait coordination in those with PD who experience FOG, those with PD who do not experience FOG, healthy older adults, and healthy young adults. Methods Eleven participants with PD and FOG, 16 with PD and no FOG, 18 healthy older, and 19 healthy young adults walked across a GAITRite walkway under four conditions: Natural, Fast (+50% of preferred cadence), Small (−50% of preferred step length), and SmallFast (+50% cadence and −50% step length). Coordination (i.e. phase coordination index) was measured for each participant during each condition and analyzed using mixed model repeated measure ANOVAs. Results FOG was not elicited. Decreasing step length or decreasing step length and increasing cadence together affected coordination. Small steps combined with fast cadence resulted in poorer coordination in both groups with PD compared to healthy young adults and in those with PD and FOG compared to healthy older adults. Conclusions Coordination deficits can be identified in those with PD by having them walk with small steps combined with fast cadence. Short steps produced at high rate elicit worse coordination than short steps or fast steps alone. PMID:23333356
Meshkat, Nazanin; Teklu, Sisay; Hunchak, Cheryl
2018-04-06
To design and implement an emergency medicine (EM) postgraduate training curriculum to support the establishment of the first EM residency program at Addis Ababa University (AAU). In response to the Ethiopian Federal Ministry of Health mandate to develop EM services in Ethiopia, University of Toronto EM faculty were invited to develop and deliver EM content and expertise for the first EM postgraduate residency training program at AAU. The Toronto Addis Ababa Academic Collaboration-EM (TAAAC-EM) used five steps of a six-step approach to guide curriculum development and implementation: 1. Problem identification and general needs assessment, 2. Targeted needs assessment using indirect methods (interviews and site visits of the learners and learning environment), 3. Defining goals and objectives, 4. Choosing educational strategies and curriculum map development and 5. The needs assessment identified a learning environment with appropriate, though limited, resources for the implementation of an EM residency program. A lack of educational activities geared towards EM practice was identified, specifically of active learning techniques (ALTs) such as bedside teaching, simulation and procedural teaching. A curriculum map was devised to supplement the AAU EM residency program curriculum. The TAAAC-EM curriculum was divided into three distinct streams: clinical, clinical epidemiology and EM administration. The clinical sessions were divided into didactic and ALTs including practical/procedural and simulation sessions, and bedside teaching was given a strong emphasis. Implementation is currently in its seventh year, with continuous monitoring and revisions of the curriculum to meet evolving needs. We have outlined the design and implementation of the TAAAC-EM curriculum; an evaluation of this curriculum is currently underway. As EM spreads as a specialty throughout Africa and other resource-limited regions, this model can serve as a working guide for similar bi-institutional educational partnerships seeking to develop novel EM postgraduate training programs.
Stretching single atom contacts at multiple subatomic step-length.
Wei, Yi-Min; Liang, Jing-Hong; Chen, Zhao-Bin; Zhou, Xiao-Shun; Mao, Bing-Wei; Oviedo, Oscar A; Leiva, Ezequiel P M
2013-08-14
This work describes jump-to-contact STM-break junction experiments leading to novel statistical distribution of last-step length associated with conductance of a single atom contact. Last-step length histograms are observed with up to five for Fe and three for Cu peaks at integral multiples close to 0.075 nm, a subatomic distance. A model is proposed in terms of gliding from a fcc hollow-site to a hcp hollow-site of adjacent atomic planes at 1/3 regular layer spacing along with tip stretching to account for the multiple subatomic step-length behavior.
NASA Astrophysics Data System (ADS)
Zhao, Xu; Takaya, Satoshi; Muraoka, Mikio
2017-08-01
Recently, we detected length-dependent electromigration (EM) behavior in Sn-58Bi (SB) solder and revealed the existence of Bi back-flow, which retards EM-induced Bi segregation and is dependent on solder length. The cause of the back-flow is attributed to an oxide layer formed on the SB solder. At present, underfill (UF) material is commonly used in flip-chip packaging as filler between chip and substrate to surround solder bumps. In this study, we quantitatively investigated the effect of UF material as a passivation layer on EM in SB solder strips. EM tests on SB solder strips with length of 50 μm, 100 μm, and 150 μm were conducted simultaneously. Some samples were coated with commercial thermosetting epoxy UF material, which acted as a passivation layer on the Cu-SB-Cu interconnections. The value of the critical product for SB solder was estimated to be 38 A/cm to 43 A/cm at 353 K to 373 K without UF coating and 59 A/cm at 373 K with UF coating. The UF material acting as a passivation layer suppressed EM-induced Bi segregation and increased the threshold current density by 37% to 55%. However, at very high current density, this effect became very slight. In addition, Bi atoms can diffuse to the anode side through the Sn phase, hence addition of microelements to the Sn phase to form obstacles, such as intermetallic compounds, may retard Bi segregation in SB solder.
SU-F-J-152: Accuracy of Charge Particle Transport in Magnetic Fields Using EGSnrc
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mainegra-Hing, E; Bouchard, H; Tessier, F
Purpose: Determine accuracy of the current implementation of electron transport under magnetic fields in EGSnrc by means of single scattering (SS) and Fano convergence tests, and establish quantitatively the electron step size restriction required to achieve a desired level of accuracy for ionization chamber dosimetry. Methods: Condensed history (CH) dose calculations are compared to SS results for a PTW30013 ionization chamber irradiated in air by a 60Co photon beam. CH dose results for this chamber irradiated in a water phantom by a source of mono-energetic electrons are compared to the prediction of Fano’s theorem for step size restrictions EM ESTEPEmore » from 0.01 to 0.1 and strengths of 0.5 T, 1.0 T, and 1.5 T. Results: CH calculations in air for 60Co photons using an EM ESTEPE of 0.25 overestimate SS values by 6% for a 1.5 T field and by 1.5% for a 0.5 T field. Agreement improves with decreasing EM ESTEPE reducing this difference at 0.02 to 0.13% and 0.04% for 1.5 T and 0.5 T respectively. CH results converge with decreasing EM ESTEPE reaching an agreement of 0.2% at a value of EM ESTEPE of 0.01 for 100 keV electrons. SS results at 100 keV for 1.5 T show the same EM ESTEPE dependency as the CH results. Conclusion: Accurate transport of charged particles in magnetic fields is only possible if the step size is significantly restricted. An EM ESTEPE value of 0.02 is required to reproduce SS results at the 0.1% level for a calculation in air. The EM ESTEPE dependency of the SS results suggests SS is bypassed when simulating the transport of charged particles in magnetic fields. Fano test results for in water calculation suggest that only a 0.2% accuracy can be achieved with the current implementation.« less
Allet, Lara; Kim, Hogene; Ashton-Miller, James; De Mott, Trina; Richardson, James K
2014-01-01
Distal symmetric polyneuropathy increases fall risk due to inability to cope with perturbations. We aimed to 1) identify the frontal plane lower limb sensorimotor functions which are necessary for robustness to a discrete, underfoot perturbation during gait; and 2) determine whether changes in the post-perturbed step parameters could distinguish between fallers and non fallers. Forty-two subjects (16 healthy old and 26 with diabetic PN) participated. Frontal plane lower limb sensorimotor functions were determined using established laboratory-based techniques. The subjects' most extreme alterations in step width or step length in response to a perturbation were measured. In addition, falls and fall-related injuries were prospectively recorded. Ankle proprioceptive threshold (APrT; p=.025) and hip abduction rate of torque generation (RTG; p=.041) independently predicted extreme step length after medial perturbation, with precise APrT and greater hip RTG allowing maintenance of step length. Injured subjects demonstrated greater extreme step length changes after medial perturbation than non-injured subjects (percent change = 18.5 ± 9.2 vs. 11.3 ± 4.57; p = .01). The ability to rapidly generate frontal plane hip strength and/or precisely perceive motion at the ankle is needed to maintain a normal step length after perturbation, a parameter which distinguishes between subjects sustaining a fall-related injury and those who did not. © 2014.
Allet, L; Kim, H; Ashton-Miller, JA; De Mott, T; Richardson, JK
2013-01-01
Aims Distal symmetric polyneuropathy increases fall risk due to inability to cope with perturbations. We aimed to 1) identify the frontal plane lower limb sensorimotor functions which are necessary for robustness to a discrete, underfoot perturbation during gait; and 2) determine whether changes in the post-perturbed step parameters could distinguish between fallers and non fallers. Methods Forty-two subjects (16 healthy old and 26 with diabetic PN) participated. Frontal plane lower limb sensorimotor functions were determined using established laboratory-based techniques. The subjects' most extreme alterations in step width or step length in response to a perturbation were measured. In addition, falls and fall-related injuries were prospectively recorded. Results Ankle proprioceptive threshold (APrT; p=.025) and hip abduction rate of torque generation (RTG; p=.041) independently predicted extreme step length after medial perturbation, with precise APrT and greater hip RTG allowing maintenance of step length. Fallers demonstrated greater extreme step length changes after medial perturbation than non fallers (percent change = 16.41±8.42 vs 11.0±4.95; p=.06) Conclusions The ability to rapidly generate frontal plane hip strength and/or precisely perceive motion at the ankle is needed to maintain a normal step length after perturbation, a parameter, which distinguishes between fallers and non fallers. PMID:24183899
Optimization of the nanotwin-induced zigzag surface of copper by electromigration
NASA Astrophysics Data System (ADS)
Chen, Hsin-Ping; Huang, Chun-Wei; Wang, Chun-Wen; Wu, Wen-Wei; Liao, Chien-Neng; Chen, Lih-Juann; Tu, King-Ning
2016-01-01
By adding nanotwins to Cu, the surface electromigration (EM) slows down. The atomic mobility of the surface step-edges is retarded by the triple points where a twin meets a free surface to form a zigzag-type surface. We observed that EM can alter the zigzag surface structure to optimize the reduction of EM, according to Le Chatelier's principle. Statistically, the optimal alternation is to change an arbitrary (111)/(hkl) zigzag pair to a pair having a very low index (hkl) plane, especially the (200) plane. Using in situ ultrahigh vacuum and high-resolution transmission electron microscopy, we examined the effects of different zigzag surfaces on the rate of EM. The calculated rate of surface EM can be decreased by a factor of ten.By adding nanotwins to Cu, the surface electromigration (EM) slows down. The atomic mobility of the surface step-edges is retarded by the triple points where a twin meets a free surface to form a zigzag-type surface. We observed that EM can alter the zigzag surface structure to optimize the reduction of EM, according to Le Chatelier's principle. Statistically, the optimal alternation is to change an arbitrary (111)/(hkl) zigzag pair to a pair having a very low index (hkl) plane, especially the (200) plane. Using in situ ultrahigh vacuum and high-resolution transmission electron microscopy, we examined the effects of different zigzag surfaces on the rate of EM. The calculated rate of surface EM can be decreased by a factor of ten. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05418d
A Survey of Emergency Medicine Residents' Use of Educational Podcasts.
Riddell, Jeff; Swaminathan, Anand; Lee, Monica; Mohamed, Abdiwahab; Rogers, Rob; Rezaie, Salim R
2017-02-01
Emergency medicine (EM) educational podcasts have become increasingly popular. Residents spend a greater percentage of their time listening to podcasts than they do using other educational materials. Despite this popularity, research into podcasting in the EM context is sparse. We aimed to determine EM residents' consumption habits, optimal podcast preferences, and motivation for listening to EM podcasts. We created a survey and emailed it to EM residents at all levels of training at 12 residencies across the United States from September 2015 to June 2016. In addition to demographics, the 20-question voluntary survey asked questions exploring three domains: habits, attention, and motivation. We used descriptive statistics to analyze results. Of the 605 residents invited to participate, 356 (n= 60.3%) completed the survey. The vast majority listen to podcasts at least once a month (88.8%). Two podcasts were the most popular by a wide margin, with 77.8% and 62.1% regularly listening to Emergency Medicine: Reviews and Perspectives ( EM:RAP ) and the EMCrit Podcast , respectively; 84.6% reported the ideal length of a podcast was less than 30 minutes. Residents reported their motivation to listen to EM podcasts was to "Keep up with current literature" (88.5%) and "Learn EM core content" (70.2%). Of those responding, 72.2% said podcasts change their clinical practice either "somewhat" or "very much." The results of this survey study suggest most residents listen to podcasts at least once a month, prefer podcasts less than 30 minutes in length, have several motivations for choosing podcasts, and report that podcasts change their clinical practice.
Effects of protocol step length on biomechanical measures in swimming.
Barbosa, Tiago M; de Jesus, Kelly; Abraldes, J Arturo; Ribeiro, João; Figueiredo, Pedro; Vilas-Boas, João Paulo; Fernandes, Ricardo J
2015-03-01
The assessment of energetic and mechanical parameters in swimming often requires the use of an intermittent incremental protocol, whose step lengths are corner stones for the efficiency of the evaluation procedures. To analyze changes in swimming kinematics and interlimb coordination behavior in 3 variants, with different step lengths, of an intermittent incremental protocol. Twenty-two male swimmers performed n×di variants of an intermittent and incremental protocol (n≤7; d1=200 m, d2=300 m, and d3=400 m). Swimmers were videotaped in the sagittal plane for 2-dimensional kinematical analysis using a dual-media setup. Video images were digitized with a motion-capture system. Parameters that were assessed included the stroke kinematics, the segmental and anatomical landmark kinematics, and interlimb coordination. Movement efficiency was also estimated. There were no significant variations in any of the selected variables according to the step lengths. A high to very high relationship was observed between step lengths. The bias was much reduced and the 95%CI fairly tight. Since there were no meaningful differences between the 3 protocol variants, the 1 with shortest step length (ie, 200 m) should be adopted for logistical reasons.
Spatiotemporal Variables of Able-bodied and Amputee Sprinters in Men's 100-m Sprint.
Hobara, H; Kobayashi, Y; Mochimaru, M
2015-06-01
The difference in world records set by able-bodied sprinters and amputee sprinters in the men's 100-m sprint is still approximately 1 s (as of 28 March 2014). Theoretically, forward velocity in a 100-m sprint is the product of step frequency and step length. The goal of this study was to examine the hypothesis that differences in the sprint performance of able-bodied and amputee sprinters would be due to a shorter step length rather than lower step frequency. Men's elite-level 100-m races with a total of 36 able-bodied, 25 unilateral and 17 bilateral amputee sprinters were analyzed from the publicly available internet broadcasts of 11 races. For each run of each sprinter, the average forward velocity, step frequency and step length over the whole 100-m distance were analyzed. The average forward velocity of able-bodied sprinters was faster than that of the other 2 groups, but there was no significant difference in average step frequency among the 3 groups. However, the average step length of able-bodied sprinters was significantly longer than that of the other 2 groups. These results suggest that the differences in sprint performance between 2 groups would be due to a shorter step length rather than lower step frequency. © Georg Thieme Verlag KG Stuttgart · New York.
Simplifying Facility and Event Scheduling: Saving Time and Money.
ERIC Educational Resources Information Center
Raasch, Kevin
2003-01-01
Describes a product called the Event Management System (EMS), a computer software program to manage facility and event scheduling. Provides example of the school district and university uses of EMS. Describes steps in selecting a scheduling-management system. (PKP)
A User’s Guide to the ALiEM Emergency Medicine Match Advice Web Series
Gisondi, Michael A.; Fant, Abra; Shakeri, Nahzinine; Schnapp, Benjamin H.; Lin, Michelle
2017-01-01
ALiEM EM Match Advice is a web series hosted on the Academic Life in Emergency Medicine website. The intended audience includes senior medical students seeking a residency in emergency medicine (EM) and the faculty members who advise them. Each episode features a panel of three EM program directors who discuss a critical step in the residency application process. This article serves as a user’s guide to the series, including a timeline for viewing each episode, brief summaries of the panel discussions, and reflection questions for discussion between students and their faculty advisors. PMID:28611891
A User's Guide to the ALiEM Emergency Medicine Match Advice Web Series.
Gisondi, Michael A; Fant, Abra; Shakeri, Nahzinine; Schnapp, Benjamin H; Lin, Michelle
2017-06-01
ALiEM EM Match Advice is a web series hosted on the Academic Life in Emergency Medicine website. The intended audience includes senior medical students seeking a residency in emergency medicine (EM) and the faculty members who advise them. Each episode features a panel of three EM program directors who discuss a critical step in the residency application process. This article serves as a user's guide to the series, including a timeline for viewing each episode, brief summaries of the panel discussions, and reflection questions for discussion between students and their faculty advisors.
Kimoto, Minoru; Okada, Kyoji; Sakamoto, Hitoshi; Kondou, Takanori
2017-05-01
[Purpose] To improve walking efficiency could be useful for reducing fatigue and extending possible period of walking in children with cerebral palsy (CP). For this purpose, current study compared conventional parameters of gross motor performance, step length, and cadence in the evaluation of walking efficiency in children with CP. [Subjects and Methods] Thirty-one children with CP (21 boys, 10 girls; mean age, 12.3 ± 2.7 years) participated. Parameters of gross motor performance, including the maximum step length (MSL), maximum side step length, step number, lateral step up number, and single leg standing time, were measured in both dominant and non-dominant sides. Spatio-temporal parameters of walking, including speed, step length, and cadence, were calculated. Total heart beat index (THBI), a parameter of walking efficiency, was also calculated from heartbeats and walking distance in 10 minutes of walking. To analyze the relationships between these parameters and the THBI, the coefficients of determination were calculated using stepwise analysis. [Results] The MSL of the dominant side best accounted for the THBI (R 2 =0.759). [Conclusion] The MSL of the dominant side was the best explanatory parameter for walking efficiency in children with CP.
Callachan, Edward L.; Alsheikh-Ali, Alawi A.; Bruijns, Stevan; Wallis, Lee A.
2015-01-01
Introduction Physician perceptions about emergency medical services (EMS) are important determinants of improving pre-hospital care for cardiac emergencies. No data exist on physician attitudes towards EMS care of patients with ST-Elevation Myocardial Infarction (STEMI) in the Emirate of Abu Dhabi. Objectives To describe the perceptions towards EMS among physicians caring for patients with STEMI in Abu Dhabi. Methods We surveyed a convenience sample of physicians involved in the care of patients with STEMI (emergency medicine, cardiology, cardiothoracic surgery and intensive care) in four government facilities with 24/7 Primary PCI in the Emirate of Abu Dhabi. Surveys were distributed using dedicated email links, and used 5-point Likert scales to assess perceptions and attitudes to EMS. Results Of 106 physician respondents, most were male (82%), practicing in emergency medicine (47%) or cardiology (44%) and the majority (63%) had been in practice for >10 years. Less than half of the responders (42%) were “Somewhat Satisfied” (35%) or “Very Satisfied” (7%) with current EMS level of care for STEMI patients. Most respondents were “Very Likely” (67%) to advise a patient with a cardiac emergency to use EMS, but only 39% felt the same for themselves or their family. Most responders were supportive (i.e. “Strongly Agree”) of the following steps to improve EMS care: 12-lead ECG and telemetry to ED by EMS (69%), EMS triage of STEMI to PCI facilities (65%), and activation of PCI teams by EMS (58%). Only 19% were supportive of pre-hospital fibrinolytics by EMS. There were no significant differences in the responses among the specialties. Conclusions Most physicians involved in STEMI care in Abu Dhabi are very likely to advise patients to use EMS for a cardiac emergency, but less likely to do so for themselves or their families. Different specialties had concordant opinions regarding steps to improve pre-hospital EMS care for STEMI. PMID:26778900
DEVELOPMENT OF COMPUTATIONAL TOOLS FOR OPTIMAL IDENTIFICATION OF BIOLOGICAL NETWORKS
Following the theoretical analysis and computer simulations, the next step for the development of SNIP will be a proof-of-principle laboratory application. Specifically, we have obtained a synthetic transcriptional cascade (harbored in Escherichia coli...
A Pearson Random Walk with Steps of Uniform Orientation and Dirichlet Distributed Lengths
NASA Astrophysics Data System (ADS)
Le Caër, Gérard
2010-08-01
A constrained diffusive random walk of n steps in ℝ d and a random flight in ℝ d , which are equivalent, were investigated independently in recent papers (J. Stat. Phys. 127:813, 2007; J. Theor. Probab. 20:769, 2007, and J. Stat. Phys. 131:1039, 2008). The n steps of the walk are independent and identically distributed random vectors of exponential length and uniform orientation. Conditioned on the sum of their lengths being equal to a given value l, closed-form expressions for the distribution of the endpoint of the walk were obtained altogether for any n for d=1,2,4. Uniform distributions of the endpoint inside a ball of radius l were evidenced for a walk of three steps in 2D and of two steps in 4D. The previous walk is generalized by considering step lengths which have independent and identical gamma distributions with a shape parameter q>0. Given the total walk length being equal to 1, the step lengths have a Dirichlet distribution whose parameters are all equal to q. The walk and the flight above correspond to q=1. Simple analytical expressions are obtained for any d≥2 and n≥2 for the endpoint distributions of two families of walks whose q are integers or half-integers which depend solely on d. These endpoint distributions have a simple geometrical interpretation. Expressed for a two-step planar walk whose q=1, it means that the distribution of the endpoint on a disc of radius 1 is identical to the distribution of the projection on the disc of a point M uniformly distributed over the surface of the 3D unit sphere. Five additional walks, with a uniform distribution of the endpoint in the inside of a ball, are found from known finite integrals of products of powers and Bessel functions of the first kind. They include four different walks in ℝ3, two of two steps and two of three steps, and one walk of two steps in ℝ4. Pearson-Liouville random walks, obtained by distributing the total lengths of the previous Pearson-Dirichlet walks according to some specified probability law are finally discussed. Examples of unconstrained random walks, whose step lengths are gamma distributed, are more particularly considered.
Biomechanical influences on balance recovery by stepping.
Hsiao, E T; Robinovitch, S N
1999-10-01
Stepping represents a common means for balance recovery after a perturbation to upright posture. Yet little is known regarding the biomechanical factors which determine whether a step succeeds in preventing a fall. In the present study, we developed a simple pendulum-spring model of balance recovery by stepping, and used this to assess how step length and step contact time influence the effort (leg contact force) and feasibility of balance recovery by stepping. We then compared model predictions of step characteristics which minimize leg contact force to experimentally observed values over a range of perturbation strengths. At all perturbation levels, experimentally observed step execution times were higher than optimal, and step lengths were smaller than optimal. However, the predicted increase in leg contact force associated with these deviations was substantial only for large perturbations. Furthermore, increases in the strength of the perturbation caused subjects to take larger, quicker steps, which reduced their predicted leg contact force. We interpret these data to reflect young subjects' desire to minimize recovery effort, subject to neuromuscular constraints on step execution time and step length. Finally, our model predicts that successful balance recovery by stepping is governed by a coupling between step length, step execution time, and leg strength, so that the feasibility of balance recovery decreases unless declines in one capacity are offset by enhancements in the others. This suggests that one's risk for falls may be affected more by small but diffuse neuromuscular impairments than by larger impairment in a single motor capacity.
Scaling laws in decaying helical hydromagnetic turbulence
NASA Astrophysics Data System (ADS)
Christensson, M.; Hindmarsh, M.; Brandenburg, A.
2005-07-01
We study the evolution of growth and decay laws for the magnetic field coherence length ξ, energy E_M and magnetic helicity H in freely decaying 3D MHD turbulence. We show that with certain assumptions, self-similarity of the magnetic power spectrum alone implies that ξ σm t1/2. This in turn implies that magnetic helicity decays as Hσm t-2s, where s=(ξ_diff/ξH)2, in terms of ξ_diff, the diffusion length scale, and ξ_H, a length scale defined from the helicity power spectrum. The relative magnetic helicity remains constant, implying that the magnetic energy decays as E_M σm t-1/2-2s. The parameter s is inversely proportional to the magnetic Reynolds number Re_M, which is constant in the self-similar regime.
A Survey of Emergency Medicine Residents’ Use of Educational Podcasts
Riddell, Jeff; Swaminathan, Anand; Lee, Monica; Mohamed, Abdiwahab; Rogers, Rob; Rezaie, Salim R.
2017-01-01
Introduction Emergency medicine (EM) educational podcasts have become increasingly popular. Residents spend a greater percentage of their time listening to podcasts than they do using other educational materials. Despite this popularity, research into podcasting in the EM context is sparse. We aimed to determine EM residents’ consumption habits, optimal podcast preferences, and motivation for listening to EM podcasts. Methods We created a survey and emailed it to EM residents at all levels of training at 12 residencies across the United States from September 2015 to June 2016. In addition to demographics, the 20-question voluntary survey asked questions exploring three domains: habits, attention, and motivation. We used descriptive statistics to analyze results. Results Of the 605 residents invited to participate, 356 (n= 60.3%) completed the survey. The vast majority listen to podcasts at least once a month (88.8%). Two podcasts were the most popular by a wide margin, with 77.8% and 62.1% regularly listening to Emergency Medicine: Reviews and Perspectives (EM:RAP) and the EMCrit Podcast, respectively; 84.6% reported the ideal length of a podcast was less than 30 minutes. Residents reported their motivation to listen to EM podcasts was to “Keep up with current literature” (88.5%) and “Learn EM core content” (70.2%). Of those responding, 72.2% said podcasts change their clinical practice either “somewhat” or “very much.” Conclusion The results of this survey study suggest most residents listen to podcasts at least once a month, prefer podcasts less than 30 minutes in length, have several motivations for choosing podcasts, and report that podcasts change their clinical practice. PMID:28210357
Emergence of an optimal search strategy from a simple random walk
Sakiyama, Tomoko; Gunji, Yukio-Pegio
2013-01-01
In reports addressing animal foraging strategies, it has been stated that Lévy-like algorithms represent an optimal search strategy in an unknown environment, because of their super-diffusion properties and power-law-distributed step lengths. Here, starting with a simple random walk algorithm, which offers the agent a randomly determined direction at each time step with a fixed move length, we investigated how flexible exploration is achieved if an agent alters its randomly determined next step forward and the rule that controls its random movement based on its own directional moving experiences. We showed that our algorithm led to an effective food-searching performance compared with a simple random walk algorithm and exhibited super-diffusion properties, despite the uniform step lengths. Moreover, our algorithm exhibited a power-law distribution independent of uniform step lengths. PMID:23804445
Emergence of an optimal search strategy from a simple random walk.
Sakiyama, Tomoko; Gunji, Yukio-Pegio
2013-09-06
In reports addressing animal foraging strategies, it has been stated that Lévy-like algorithms represent an optimal search strategy in an unknown environment, because of their super-diffusion properties and power-law-distributed step lengths. Here, starting with a simple random walk algorithm, which offers the agent a randomly determined direction at each time step with a fixed move length, we investigated how flexible exploration is achieved if an agent alters its randomly determined next step forward and the rule that controls its random movement based on its own directional moving experiences. We showed that our algorithm led to an effective food-searching performance compared with a simple random walk algorithm and exhibited super-diffusion properties, despite the uniform step lengths. Moreover, our algorithm exhibited a power-law distribution independent of uniform step lengths.
Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D
2017-03-01
Anterior cruciate ligament reconstruction is associated with early onset knee osteoarthritis. Running is a typical activity following this surgery, but elevated knee joint contact forces are thought to contribute to osteoarthritis degenerative processes. It is therefore clinically relevant to identify interventions to reduce contact forces during running among individuals after anterior cruciate ligament reconstruction. The primary purpose of this study was to evaluate the effect of reducing step length during running on patellofemoral and tibiofemoral joint contact forces among people with a history of anterior cruciate ligament reconstruction. Inter limb knee joint contact force differences during running were also examined. 18 individuals at an average of 54.8months after unilateral anterior cruciate ligament reconstruction ran in 3 step length conditions (preferred, -5%, -10%). Bilateral patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, loading rate, impulse, and impulse per kilometer were evaluated between step length conditions and limbs using separate 2 factor analyses of variance. Reducing step length 5% decreased patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, impulse, and impulse per kilometer bilaterally. A 10% step length reduction further decreased peak forces and force impulses, but did not further reduce force impulses per kilometer. Tibiofemoral joint impulse, impulse per kilometer, and patellofemoral joint loading rate were lower in the previously injured limb compared to the contralateral limb. Running with a shorter step length is a feasible clinical intervention to reduce knee joint contact forces during running among people with a history of anterior cruciate ligament reconstruction. Copyright © 2017 Elsevier Ltd. All rights reserved.
Preamble to the Integrated Science Assessments (ISA)
The Preamble to the Integrated Science Assessments, or "Preamble", is an overview document outlining the basic steps and criteria used in developing the Integrated Science Assessments (ISA). Previously included as part of the ISA, it will now be referenced by each ISA as...
Robust w-Estimators for Cryo-EM Class Means
Huang, Chenxi; Tagare, Hemant D.
2016-01-01
A critical step in cryogenic electron microscopy (cryo-EM) image analysis is to calculate the average of all images aligned to a projection direction. This average, called the “class mean”, improves the signal-to-noise ratio in single particle reconstruction (SPR). The averaging step is often compromised because of outlier images of ice, contaminants, and particle fragments. Outlier detection and rejection in the majority of current cryo-EM methods is done using cross-correlation with a manually determined threshold. Empirical assessment shows that the performance of these methods is very sensitive to the threshold. This paper proposes an alternative: a “w-estimator” of the average image, which is robust to outliers and which does not use a threshold. Various properties of the estimator, such as consistency and influence function are investigated. An extension of the estimator to images with different contrast transfer functions (CTFs) is also provided. Experiments with simulated and real cryo-EM images show that the proposed estimator performs quite well in the presence of outliers. PMID:26841397
Robust w-Estimators for Cryo-EM Class Means.
Huang, Chenxi; Tagare, Hemant D
2016-02-01
A critical step in cryogenic electron microscopy (cryo-EM) image analysis is to calculate the average of all images aligned to a projection direction. This average, called the class mean, improves the signal-to-noise ratio in single-particle reconstruction. The averaging step is often compromised because of the outlier images of ice, contaminants, and particle fragments. Outlier detection and rejection in the majority of current cryo-EM methods are done using cross-correlation with a manually determined threshold. Empirical assessment shows that the performance of these methods is very sensitive to the threshold. This paper proposes an alternative: a w-estimator of the average image, which is robust to outliers and which does not use a threshold. Various properties of the estimator, such as consistency and influence function are investigated. An extension of the estimator to images with different contrast transfer functions is also provided. Experiments with simulated and real cryo-EM images show that the proposed estimator performs quite well in the presence of outliers.
Injuries to emergency medicine residents on EMS rotations.
Cone, D C; McNamara, R M
1998-01-01
To study the incidence and nature of injuries sustained by emergency medicine (EM) residents during EMS rotations, and steps taken at EM residency programs to increase resident safety during field activities. An eight-question survey form was mailed to all 114 U.S. EM residency directors, with a second mailing to nonresponders eight weeks after the initial mailing. A total of 105 surveys were returned (92%). Six surveys were from new programs whose residents have not yet rotated on EMS. These were excluded from further analysis, leaving 99 programs. Of these, 91 (92%) reported no injuries. One EM resident died in a helicopter crash in 1985. Seven other injury events were reported: 1) facial lacerations, rib fractures, and a shoulder injury in an ambulance accident; 2) an open finger fracture (crushed by a backboard); 3) contusions and a concussion when an ambulance was struck by a fire engine; 4) a groin pull sustained while entering a helicopter; 5) bilateral metatarsal fractures in a fall; 6) rib fractures, a pneumothorax, and a concussion in an ambulance accident; and 7) "minor injuries" sustained in a crash while responding to a scene in a program-owned response vehicle. Actions taken at residency programs to reduce the risk of injury include the use of ballistic vests (four programs), requiring helmets on flights (five programs), and changing flight experience from mandatory to optional (two programs). Ten programs (10%) reported using ground scene safety lectures, and nine programs (15% of those offering flights) reported various types of flight safety instruction. Sixty-nine programs (70%) reported no formal field safety training or other active steps to increase resident safety on EMS rotations. Injuries sustained by EM residents during EMS rotations are uncommon but nontrivial, with several serious injuries and one fatality reported. The majority of EM residency programs have no formal safety training programs for EMS rotations.
Variability in the Length and Frequency of Steps of Sighted and Visually Impaired Walkers
ERIC Educational Resources Information Center
Mason, Sarah J.; Legge, Gordon E.; Kallie, Christopher S.
2005-01-01
The variability of the length and frequency of steps was measured in sighted and visually impaired walkers at three different paces. The variability was low, especially at the preferred pace, and similar for both groups. A model incorporating step counts and step frequency provides good estimates of the distance traveled. Applications to…
Empirical scaling of the length of the longest increasing subsequences of random walks
NASA Astrophysics Data System (ADS)
Mendonça, J. Ricardo G.
2017-02-01
We provide Monte Carlo estimates of the scaling of the length L n of the longest increasing subsequences of n-step random walks for several different distributions of step lengths, short and heavy-tailed. Our simulations indicate that, barring possible logarithmic corrections, {{L}n}∼ {{n}θ} with the leading scaling exponent 0.60≲ θ ≲ 0.69 for the heavy-tailed distributions of step lengths examined, with values increasing as the distribution becomes more heavy-tailed, and θ ≃ 0.57 for distributions of finite variance, irrespective of the particular distribution. The results are consistent with existing rigorous bounds for θ, although in a somewhat surprising manner. For random walks with step lengths of finite variance, we conjecture that the correct asymptotic behavior of L n is given by \\sqrt{n}\\ln n , and also propose the form for the subleading asymptotics. The distribution of L n was found to follow a simple scaling form with scaling functions that vary with θ. Accordingly, when the step lengths are of finite variance they seem to be universal. The nature of this scaling remains unclear, since we lack a working model, microscopic or hydrodynamic, for the behavior of the length of the longest increasing subsequences of random walks.
ERIC Educational Resources Information Center
Rota, Viviana; Perucca, Laura; Simone, Anna; Tesio, Luigi
2011-01-01
In healthy adults, the step length/cadence ratio [walk ratio (WR) in mm/(steps/min) and normalized for height] is known to be constant around 6.5 mm/(step/min). It is a speed-independent index of the overall neuromotor gait control, in as much as it reflects energy expenditure, balance, between-step variability, and attentional demand. The speed…
Donelan, J Maxwell; Kram, Rodger; Kuo, Arthur D
2002-12-01
In the single stance phase of walking, center of mass motion resembles that of an inverted pendulum. Theoretically, mechanical work is not necessary for producing the pendular motion, but work is needed to redirect the center of mass velocity from one pendular arc to the next during the transition between steps. A collision model predicts a rate of negative work proportional to the fourth power of step length. Positive work is required to restore the energy lost, potentially exacting a proportional metabolic cost. We tested these predictions with humans (N=9) walking over a range of step lengths (0.4-1.1 m) while keeping step frequency fixed at 1.8 Hz. We measured individual limb external mechanical work using force plates, and metabolic rate using indirect calorimetry. As predicted, average negative and positive external mechanical work rates increased with the fourth power of step length (from 1 W to 38 W; r(2)=0.96). Metabolic rate also increased with the fourth power of step length (from 7 W to 379 W; r(2)=0.95), and linearly with mechanical work rate. Mechanical work for step-to-step transitions, rather than pendular motion itself, appears to be a major determinant of the metabolic cost of walking.
The PX-EM algorithm for fast stable fitting of Henderson's mixed model
Foulley, Jean-Louis; Van Dyk, David A
2000-01-01
This paper presents procedures for implementing the PX-EM algorithm of Liu, Rubin and Wu to compute REML estimates of variance covariance components in Henderson's linear mixed models. The class of models considered encompasses several correlated random factors having the same vector length e.g., as in random regression models for longitudinal data analysis and in sire-maternal grandsire models for genetic evaluation. Numerical examples are presented to illustrate the procedures. Much better results in terms of convergence characteristics (number of iterations and time required for convergence) are obtained for PX-EM relative to the basic EM algorithm in the random regression. PMID:14736399
Chen, Weile; Koide, Roger T.; Eissenstat, David M.
2017-04-26
Plants compete for nutrients using a range of strategies. We investigated nutrient foraging within nutrient hot-spots simultaneously available to plant species with diverse root traits. We hypothesized that there would be more root proliferation by thin-root species than by thick-root species, and that root proliferation by thin-root species would limit root proliferation by thick-root species. We conducted a root ingrowth experiment in a temperate forest in eastern USA where root systems of different tree species could interact. Tree species varied in the thickness of their absorptive roots, and were associated with either ectomycorrhizal (EM) or arbuscular mycorrhizal (AM) fungi. Thus,more » there were thin- and thick-root AM and thin- and thick-root EM plant functional groups. Half the ingrowth cores were amended with organic nutrients (dried green leaves). Relative root length abundance, the proportion of total root length in a given soil volume occupied by a particular plant functional group, was calculated for the original root population and ingrowth roots after 6 months. The shift in relative root length abundance from original to ingrowth roots was positive in thin-root species but negative in thick-root species (p < .001), especially in unamended patches (AM: +6% vs. -7%; EM: +8% vs. -9%). Being thin-rooted may thus allow a species to more rapidly recolonize soil after a disturbance, which may influence competition for nutrients. Moreover, we observed that nutrient additions amplified the shift in root length abundance of thin over thick roots in AM trees (+13% vs. -14%), but not in EM trees (+1% vs -3%). In contrast, phospholipid fatty acid biomarkers suggested that EM fungal hyphae strongly proliferated in nutrient hot-spots whereas AM fungal hyphae exhibited only modest proliferation. We found no evidence that when growing in the shared patch, the proliferation of thin roots inhibited the growth of thick roots. As a result, knowledge of root morphology and mycorrhizal type of co-existing tree species may improve prediction of patch exploitation and nutrient acquisition in heterogeneous soils.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Weile; Koide, Roger T.; Eissenstat, David M.
Plants compete for nutrients using a range of strategies. We investigated nutrient foraging within nutrient hot-spots simultaneously available to plant species with diverse root traits. We hypothesized that there would be more root proliferation by thin-root species than by thick-root species, and that root proliferation by thin-root species would limit root proliferation by thick-root species. We conducted a root ingrowth experiment in a temperate forest in eastern USA where root systems of different tree species could interact. Tree species varied in the thickness of their absorptive roots, and were associated with either ectomycorrhizal (EM) or arbuscular mycorrhizal (AM) fungi. Thus,more » there were thin- and thick-root AM and thin- and thick-root EM plant functional groups. Half the ingrowth cores were amended with organic nutrients (dried green leaves). Relative root length abundance, the proportion of total root length in a given soil volume occupied by a particular plant functional group, was calculated for the original root population and ingrowth roots after 6 months. The shift in relative root length abundance from original to ingrowth roots was positive in thin-root species but negative in thick-root species (p < .001), especially in unamended patches (AM: +6% vs. -7%; EM: +8% vs. -9%). Being thin-rooted may thus allow a species to more rapidly recolonize soil after a disturbance, which may influence competition for nutrients. Moreover, we observed that nutrient additions amplified the shift in root length abundance of thin over thick roots in AM trees (+13% vs. -14%), but not in EM trees (+1% vs -3%). In contrast, phospholipid fatty acid biomarkers suggested that EM fungal hyphae strongly proliferated in nutrient hot-spots whereas AM fungal hyphae exhibited only modest proliferation. We found no evidence that when growing in the shared patch, the proliferation of thin roots inhibited the growth of thick roots. As a result, knowledge of root morphology and mycorrhizal type of co-existing tree species may improve prediction of patch exploitation and nutrient acquisition in heterogeneous soils.« less
Gama, Gabriela L; Celestino, Melissa L; Barela, José A; Forrester, Larry; Whitall, Jill; Barela, Ana M
2017-04-01
To investigate the effects of gait training with body weight support (BWS) on a treadmill versus overground in individuals with chronic stroke. Randomized controlled trial. University research laboratory. Individuals (N=28) with chronic stroke (>6mo from the stroke event). Participants were randomly assigned to receive gait training with BWS on a treadmill (n=14) or overground (n=14) 3 times a week for 6 weeks. Gait speed measured using the 10-meter walk test, endurance measured using the 6-minute walk test, functional independence measured using the motor domain of the FIM, lower limb recovery measured using the lower extremity domain of the Fugl-Meyer assessment, step length, step length symmetry ratio, and single-limb support duration. Measurements were obtained at baseline, immediately after the training session, and 6 weeks after the training session. At 1 week after the last training session, both groups improved in all outcome measures except paretic step length and step length symmetry ratio, which were improved only in the overground group (P=.01 and P=.01, respectively). At 6 weeks after the last training session, all improvements remained and the treadmill group also improved paretic step length (P<.001) but not step length symmetry ratio (P>.05). Individuals with chronic stroke equally improve gait speed and other gait parameters after 18 sessions of BWS gait training on either a treadmill or overground. Only the overground group improved step length symmetry ratio, suggesting a role of integrating overground walking into BWS interventions poststroke. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Eftaxias, K.; Potirakis, S. M.
2013-10-01
Are there credible electromagnetic (EM) potential earthquake (EQ) precursors? This a question debated in the scientific community and there may be legitimate reasons for the critical views. The negative view concerning the existence of EM potential precursors is enhanced by features that accompany their observation which are considered as paradox ones, namely, these signals: (i) are not observed at the time of EQs occurrence and during the aftershock period, (ii) are not accompanied by large precursory strain changes, (iii) are not accompanied by simultaneous geodetic or seismological precursors and (iv) their traceability is considered problematic. In this work, the detected candidate EM potential precursors are studied through a shift in thinking towards the basic science findings relative to granular packings, micron-scale plastic flow, interface depinning, fracture size effects, concepts drawn from phase transitions, self-affine notion of fracture and faulting process, universal features of fracture surfaces, recent high quality laboratory studies, theoretical models and numerical simulations. We try to contribute to the establishment of strict criteria for the definition of an emerged EM anomaly as a possibly EQ-related one, and to the explanation of potential precursory EM features which have been considered as paradoxes. A three-stage model for EQ generation by means of pre-EQ fracture-induced EM emissions is proposed. The claim that the observed EM potential precursors may permit a real-time and step-by-step monitoring of the EQ generation is tested.
A general probabilistic model for group independent component analysis and its estimation methods
Guo, Ying
2012-01-01
SUMMARY Independent component analysis (ICA) has become an important tool for analyzing data from functional magnetic resonance imaging (fMRI) studies. ICA has been successfully applied to single-subject fMRI data. The extension of ICA to group inferences in neuroimaging studies, however, is challenging due to the unavailability of a pre-specified group design matrix and the uncertainty in between-subjects variability in fMRI data. We present a general probabilistic ICA (PICA) model that can accommodate varying group structures of multi-subject spatio-temporal processes. An advantage of the proposed model is that it can flexibly model various types of group structures in different underlying neural source signals and under different experimental conditions in fMRI studies. A maximum likelihood method is used for estimating this general group ICA model. We propose two EM algorithms to obtain the ML estimates. The first method is an exact EM algorithm which provides an exact E-step and an explicit noniterative M-step. The second method is an variational approximation EM algorithm which is computationally more efficient than the exact EM. In simulation studies, we first compare the performance of the proposed general group PICA model and the existing probabilistic group ICA approach. We then compare the two proposed EM algorithms and show the variational approximation EM achieves comparable accuracy to the exact EM with significantly less computation time. An fMRI data example is used to illustrate application of the proposed methods. PMID:21517789
The stepping behavior analysis of pedestrians from different age groups via a single-file experiment
NASA Astrophysics Data System (ADS)
Cao, Shuchao; Zhang, Jun; Song, Weiguo; Shi, Chang'an; Zhang, Ruifang
2018-03-01
The stepping behavior of pedestrians with different age compositions in single-file experiment is investigated in this paper. The relation between step length, step width and stepping time are analyzed by using the step measurement method based on the calculation of curvature of the trajectory. The relations of velocity-step width, velocity-step length and velocity-stepping time for different age groups are discussed and compared with previous studies. Finally effects of pedestrian gender and height on stepping laws and fundamental diagrams are analyzed. The study is helpful for understanding pedestrian dynamics of movement. Meanwhile, it offers experimental data to develop a microscopic model of pedestrian movement by considering stepping behavior.
Ramos, Rafael Jacques; Mottin, Cláudio Corá; Alves, Letícia Biscaino; Benzano, Daniela; Padoin, Alexandre Vontobel
There is no consensus on the ideal size of intestinal loops in gastric bypass of bariatric surgeries. To evaluate the metabolic outcome of patients submitted to gastric bypass with alimentary and biliopancreatic loops of different sizes. Was conducted a retrospective cohort study in diabetic obese patients (BMI≥35 kg/m2) with metabolic syndrome submitted to gastric bypass. The patients were divided into three groups according to the size of the intestinal loop: group 1, biliopancreatic limb 50 cm length and alimentary limb 100 cm length; group 2 , biliopancreatic limb 50 cm length and alimentary limb 150 cm length; and group 3, biliopancreatic limb 100 cm length and alimentary limb 150 cm length. The effect of gastric bypass with different sizes of intestinal loops in relation to the parameters that define metabolic syndrome was determined. Sixty-three patients were evaluated, and they had a mean age of 44.7±9.4 years. All were diabetics, with 62 (98.4%) being hypertensive and 51 (82.2%) dyslipidemic. The three groups were homogeneous in relation to the variables. In 24 months, there was a remission of systemic arterial hypertension in 65% of patients in group 1, 62.5% in group 2 and 68.4% in group 3. Remission of diabetes occurred in 85% of patients in group 1, 83% in group 2 and 84% in group 3. There was no statistical difference in %LEW between the groups, and waist measurements decreased in a homogeneous way in all groups. The size of loops also had no influence on the improvement in dyslipidemia. Variation in size of intestinal loops does not appear to influence improvement in metabolic syndrome in this group of patients. Não há consenso sobre o tamanho ideal das alças intestinais no bypass gástrico em Y-de-Roux em cirurgias bariátricas. Avaliar os desfechos metabólicos de pacientes submetidos ao bypass gástrico com alça intestinal alimentar e biliopancreática de tamanhos diferentes. Realizou-se coorte retrospectiva em pacientes obesos (IMC≥35 kg/m2) diabéticos com síndrome metabólica submetidos ao bypass gástrico em Y-de-Roux. Foram divididos em três grupos conforme a dimensão das alças intestinais: grupo 1, alça biliopancreática de 50 cm e alça alimentar de 100 cm; grupo 2, alça biliopancreática de 50 cm e alça alimentar de 150 cm e grupo 3, alça biliopancreática de 100 cm e alça alimentar de 150 cm. Foram avaliados os parâmetros que compõem a síndrome metabólica. Incluíram-se 63 pacientes, com média de idade de 44.7±9.4 anos. Todos eram diabéticos, 62 (98.4%) hipertensos e 51 (82.2%) dislipidêmicos. Os três grupos eram homogêneos em relação às variáveis estudadas. Em 24 meses houve remissão da hipertensão arterial sistêmica em 65% do grupo 1, 62.5% no grupo 2 e 68.4% no grupo 3. A remissão do diabete melito tipo 2 ocorreu em 85% dos pacientes do grupo 1, 83% no grupo 2, e 84% no grupo 3. Não houve diferença estatística na porcentagem de perda do excesso de peso entre os grupos e as medidas da cintura abdominal reduziram de forma homogênea em todos os grupos. A dimensão das alças também não influenciou na melhora da dislipidemia. A variação da dimensão das alças intestinais não influenciou na melhora da síndrome metabólica neste grupo de pacientes.
Saudi EMS Students' Perception of and Attitudes toward Their Preparedness for Disaster Management
ERIC Educational Resources Information Center
Alrazeeni, Daifallah
2015-01-01
Background: Disasters led not only to the loss of life and destruction of public infrastructures, but also resulted in consequent healthcare delivery concerns. Disaster preparedness is considered one of the key steps in emergency management. EMS students had very scanty knowledge, attitude and practices about disaster preparedness and mitigation.…
Improved method of step length estimation based on inverted pendulum model.
Zhao, Qi; Zhang, Boxue; Wang, Jingjing; Feng, Wenquan; Jia, Wenyan; Sun, Mingui
2017-04-01
Step length estimation is an important issue in areas such as gait analysis, sport training, or pedestrian localization. In this article, we estimate the step length of walking using a waist-worn wearable computer named eButton. Motion sensors within this device are used to record body movement from the trunk instead of extremities. Two signal-processing techniques are applied to our algorithm design. The direction cosine matrix transforms vertical acceleration from the device coordinates to the topocentric coordinates. The empirical mode decomposition is used to remove the zero- and first-order skew effects resulting from an integration process. Our experimental results show that our algorithm performs well in step length estimation. The effectiveness of the direction cosine matrix algorithm is improved from 1.69% to 3.56% while the walking speed increased.
NASA Technical Reports Server (NTRS)
Olson, Roland E; Land, Norman S
1949-01-01
Tests were made to fill partly the need for information on the effect of afterbody dimensions on the hydrodynamic stability of a flying boat in smooth water. The dimensions investigated were depth of step, angle of afterbody keel, and length of afterbody. An analysis of the data showed that as either the afterbody length or keel angle was increased an accompanying increase in depth of step was required in order to maintain adequate landing stability. The landing-tests results have been reduced to an empirical formula giving the minimum depth of step in terms of afterbody length and keel angle. This formula is compared with results from other tank tests, and the correlation is fairly good. The formula thus becomes of use in preliminary design.
Stimulated Brillouin scattering continuous wave phase conjugation in step-index fiber optics.
Massey, Steven M; Spring, Justin B; Russell, Timothy H
2008-07-21
Continuous wave (CW) stimulated Brillouin scattering (SBS) phase conjugation in step-index optical fibers was studied experimentally and modeled as a function of fiber length. A phase conjugate fidelity over 80% was measured from SBS in a 40 m fiber using a pinhole technique. Fidelity decreases with fiber length, and a fiber with a numerical aperture (NA) of 0.06 was found to generate good phase conjugation fidelity over longer lengths than a fiber with 0.13 NA. Modeling and experiment support previous work showing the maximum interaction length which yields a high fidelity phase conjugate beam is inversely proportional to the fiber NA(2), but find that fidelity remains high over much longer fiber lengths than previous models calculated. Conditions for SBS beam cleanup in step-index fibers are discussed.
Geochemical Diversity of the Mantle: 50 Years of Acronyms
NASA Astrophysics Data System (ADS)
Hart, S. R.
2014-12-01
50 years ago, Gast, Tilton and Hedge demonstrated that the oceanic mantle is isotopically heterogeneous. 28 years ago, Zindler and Hart formalized the concept of geochemical mantle components, with an attendant, to some, odious, acronym soup. Work on a marriage of mantle geochemistry and dynamics continues unabated. We know unequivocally that the mantle is chemically heterogeneous; we do not know the scale lengths of these heterogeneities. We know unequivocally that these heterogeneities have persisted for eons (Gy); we do not know where they were formed or where they are stored. Through the kind auspices of the Plume Model, we plausibly have access to the whole mantle. The most accessible and well understood mantle reservoir is the upper depleted MORB mantle (DMM). Classically, this mantle was depleted by extraction of oceanic and continental crust from a "chondritic" bulk silicate Earth. In this post-Boyet and Carlson world, the complementary enriched reservoir may instead be hidden in the deepest mantle. In this case, DMM will become an endangered acronym. Hofmann and White (1982) argued that radiogenic Pb mantle (HIMU) is re-cycled ocean crust, and this is a comfortably viable model. It does require some ad hoc chemical manipulations during subduction. Given 2 Gy of aggregate mantle strains, the mafic component in HIMU may be of small length scale (< 50 m), possibly subsumed into the dominant peridotitic lithology. This mantle species is globally widespread. Enriched mantles (EM1 and EM2) almost certainly reflect recycling of enriched continental material. This was splendidly verified by Jackson et al (2007), with 87Sr/86Sr in Samoan EM2 lavas up to 0.721. The lithology and length scale of EM1 and EM2 is unconstrained. EM1 is globally present; EM2 is confined to the SW Pacific hotspots. FOZO is a work in progress; many would like to see it become extinct! The trace element signatures of HIMU and FOZO mantles have been constrained using melting models; in both cases the spidergrams are "enriched" with peaks at Nb-Ta of 2x and 4x bulk silicate earth, respectively, but with quite different shapes. As is typical with OIB, the derived source compositions are incompatible with the isotopic signatures, requiring a fairly recent "enrichment" event (possibly auto-metasomatism).
Jones, Brian A; Hull, Melissa A; Potanos, Kristina M; Zurakowski, David; Fitzgibbons, Shimae C; Ching, Y Avery; Duggan, Christopher; Jaksic, Tom; Kim, Heung Bae
2016-01-01
Background The International Serial Transverse Enteroplasty (STEP) Data Registry is a voluntary online database created in 2004 to collect information on patients undergoing the STEP procedure. The aim of this study was to identify preoperative factors significantly associated with 1) transplantation or death, or 2) attainment of enteral autonomy following STEP. Study Design Data were collected from September 2004 to January 2010. Univariate and multivariate logistic regression analyses were applied to determine predictors of transplantation/death or enteral autonomy post-STEP. Time to reach full enteral nutrition was estimated using a Kaplan-Meier curve. Results Fourteen of the 111 patients in the Registry were excluded due to inadequate follow-up. Of the remaining 97 patients, 11 patients died, and 5 progressed to intestinal transplantation. On multivariate analysis, higher direct bilirubin and shorter pre-STEP bowel length were independently predictive of progression to transplantation or death (p = .05 and p < .001, respectively). Of the 78 patients who were ≥7 days of age and required parenteral nutrition (PN) at the time of STEP, 37 (47%) achieved enteral autonomy after the first STEP. Longer pre-STEP bowel length was also independently associated with enteral autonomy (p = .002). The median time to reach enteral autonomy based on Kaplan-Meier analysis was 21 months (95% CI: 12-30). Conclusions Overall mortality post-STEP was 11%. Pre-STEP risk factors for progressing to transplantation or death were higher direct bilirubin and shorter bowel length. Among patients who underwent STEP for short bowel syndrome, 47% attained full enteral nutrition post-STEP. Patients with longer pre-STEP bowel length were significantly more likely to achieve enteral autonomy. PMID:23357726
Predictors of a Top Performer During Emergency Medicine Residency.
Bhat, Rahul; Takenaka, Katrin; Levine, Brian; Goyal, Nikhil; Garg, Manish; Visconti, Annette; Oyama, Leslie; Castillo, Edward; Broder, Joshua; Omron, Rodney; Hayden, Stephen
2015-10-01
Emergency Medicine (EM) residency program directors and faculty spend significant time and effort creating a residency rank list. To date, however, there have been few studies to assist program directors in determining which pre-residency variables best predict performance during EM residency. To evaluate which pre-residency variables best correlated with an applicant's performance during residency. This was a retrospective multicenter sample of all residents in the three most recent graduating classes from nine participating EM residency programs. The outcome measure of top residency performance was defined as placement in the top third of a resident's graduating class based on performance on the final semi-annual evaluation. A total of 277 residents from nine institutions were evaluated. Eight of the predictors analyzed had a significant correlation with the outcome of resident performance. Applicants' grade during home and away EM rotations, designation as Alpha Omega Alpha (AOA), U.S. Medical Licensing Examination (USMLE) Step 1 score, interview scores, "global rating" and "competitiveness" on nonprogram leadership standardized letter of recommendation (SLOR), and having five or more publications or presentations showed a significant association with residency performance. We identified several predictors of top performers in EM residency: an honors grade for an EM rotation, USMLE Step 1 score, AOA designation, interview score, high SLOR rankings from nonprogram leadership, and completion of five or more presentations and publications. EM program directors may consider utilizing these variables during the match process to choose applicants who have the highest chance of top performance during residency. Copyright © 2015 Elsevier Inc. All rights reserved.
Schwein, Adeline; Kramer, Ben; Chinnadurai, Ponraj; Walker, Sean; O'Malley, Marcia; Lumsden, Alan; Bismuth, Jean
2017-02-01
One limitation of the use of robotic catheters is the lack of real-time three-dimensional (3D) localization and position updating: they are still navigated based on two-dimensional (2D) X-ray fluoroscopic projection images. Our goal was to evaluate whether incorporating an electromagnetic (EM) sensor on a robotic catheter tip could improve endovascular navigation. Six users were tasked to navigate using a robotic catheter with incorporated EM sensors in an aortic aneurysm phantom. All users cannulated two anatomic targets (left renal artery and posterior "gate") using four visualization modes: (1) standard fluoroscopy mode (control), (2) 2D fluoroscopy mode showing real-time virtual catheter orientation from EM tracking, (3) 3D model of the phantom with anteroposterior and endoluminal view, and (4) 3D model with anteroposterior and lateral view. Standard X-ray fluoroscopy was always available. Cannulation and fluoroscopy times were noted for every mode. 3D positions of the EM tip sensor were recorded at 4 Hz to establish kinematic metrics. The EM sensor-incorporated catheter navigated as expected according to all users. The success rate for cannulation was 100%. For the posterior gate target, mean cannulation times in minutes:seconds were 8:12, 4:19, 4:29, and 3:09, respectively, for modes 1, 2, 3 and 4 (P = .013), and mean fluoroscopy times were 274, 20, 29, and 2 seconds, respectively (P = .001). 3D path lengths, spectral arc length, root mean dimensionless jerk, and number of submovements were significantly improved when EM tracking was used (P < .05), showing higher quality of catheter movement with EM navigation. The EM tracked robotic catheter allowed better real-time 3D orientation, facilitating navigation, with a reduction in cannulation and fluoroscopy times and improvement of motion consistency and efficiency. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Land, Norman S
1945-01-01
A program of model tests has been completed at Langley tank no. 1 which will furnish a qualitative guide as to the relation of length of afterbody and depth of step. The model used for the tests was a l/12-size unpowered dynamic model of a hypothetical 160,000-pound airplane. The results showed that an increase in length of afterbody requires an accompanying increase in depth of step to maintain adequate landing stability. Changing the length of afterbody and depth of step in such a manner as to maintain a given landing stability will result in only small changes in take-off stability.
Romero-Brey, Inés; Bartenschlager, Ralf
2015-01-01
As obligate intracellular parasites, viruses need to hijack their cellular hosts and reprogram their machineries in order to replicate their genomes and produce new virions. For the direct visualization of the different steps of a viral life cycle (attachment, entry, replication, assembly and egress) electron microscopy (EM) methods are extremely helpful. While conventional EM has given important information about virus-host cell interactions, the development of three-dimensional EM (3D-EM) approaches provides unprecedented insights into how viruses remodel the intracellular architecture of the host cell. During the last years several 3D-EM methods have been developed. Here we will provide a description of the main approaches and examples of innovative applications. PMID:26633469
Romero-Brey, Inés; Bartenschlager, Ralf
2015-12-03
As obligate intracellular parasites, viruses need to hijack their cellular hosts and reprogram their machineries in order to replicate their genomes and produce new virions. For the direct visualization of the different steps of a viral life cycle (attachment, entry, replication, assembly and egress) electron microscopy (EM) methods are extremely helpful. While conventional EM has given important information about virus-host cell interactions, the development of three-dimensional EM (3D-EM) approaches provides unprecedented insights into how viruses remodel the intracellular architecture of the host cell. During the last years several 3D-EM methods have been developed. Here we will provide a description of the main approaches and examples of innovative applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maltman, K.
1994-08-01
By investigating the electromagnetic (EM) chiral series for the pseudoscalar mesons at next-to-leading order, it is shown that the [pi][sup 0] EM self-energy is [ital O]([alpha][sub EM][ital m][sub [ital u],][ital d]), and hence small. This observation completes the crucial step in an earlier argument, which employed previously the vanishing of the [pi][sup 0] EM self-energy in the chiral limit, and which demonstrates that the effects of not only one-photon-exchange- but also one-photon-loop graphs must be included in order to incorporate the effects of electromagnetism in hadronic systems.
The E-Step of the MGROUP EM Algorithm. Program Statistics Research Technical Report No. 93-37.
ERIC Educational Resources Information Center
Thomas, Neal
Mislevy (1984, 1985) introduced an EM algorithm for estimating the parameters of a latent distribution model that is used extensively by the National Assessment of Educational Progress. Second order asymptotic corrections are derived and applied along with more common first order asymptotic corrections to approximate the expectations required by…
Spatial parameters of walking gait and footedness.
Zverev, Y P
2006-01-01
The present study was undertaken to assess whether footedness has effects on selected spatial and angular parameters of able-bodied gait by evaluating footprints of young adults. A total of 112 males and 93 females were selected from among students and staff members of the University of Malawi using a simple random sampling method. Footedness of subjects was assessed by the Waterloo Footedness Questionnaire Revised. Gait at natural speed was recorded using the footprint method. The following spatial parameters of gait were derived from the inked footprint sequences of subjects: step and stride lengths, gait angle and base of gait. The anthropometric measurements taken were weight, height, leg and foot length, foot breadth, shoulder width, and hip and waist circumferences. The prevalence of right-, left- and mix-footedness in the whole sample of young Malawian adults was 81%, 8.3% and 10.7%, respectively. One-way analysis of variance did not reveal a statistically significant difference between footedness categories in the mean values of anthropometric measurements (p > 0.05 for all variables). Gender differences in step and stride length values were not statistically significant. Correction of these variables for stature did not change the trend. Males had significantly broader steps than females. Normalized values of base of gait had similar gender difference. The group means of step length and normalized step length of the right and left feet were similar, for males and females. There was a significant side difference in the gait angle in both gender groups of volunteers with higher mean values on the left side compared to the right one (t = 2.64, p < 0.05 for males, and t = 2.78, p < 0.05 for females). One-way analysis of variance did not demonstrate significant difference between footedness categories in the mean values of step length, gait angle, bilateral differences in step length and gait angle, stride length, gait base and normalized gait variables of male and female volunteers (p > 0.05 for all variables). The present study demonstrated that footedness does not affect spatial and angular parameters of walking gait.
Yang, XinChao; Li, MengHui; Liu, JianHua; Ji, YiHong; Li, XiangRui; Xu, LiXin; Yan, RuoFeng; Song, XiaoKai
2017-02-16
Eimeria maxima is one of the most prevalent Eimeria species causing avian coccidiosis, and results in huge economic loss to the global poultry industry. Current control strategies, such as anti-coccidial medication and live vaccines have been limited because of their drawbacks. The third generation anticoccidial vaccines including the recombinant vaccines as well as DNA vaccines have been suggested as a promising alternative strategy. To date, only a few protective antigens of E. maxima have been reported. Hence, there is an urgent need to identify novel protective antigens of E. maxima for the development of neotype anticoccidial vaccines. With the aim of identifying novel protective genes of E. maxima, a cDNA expression library of E. maxima sporozoites was constructed using Gateway technology. Subsequently, the cDNA expression library was divided into 15 sub-libraries for cDNA expression library immunization (cDELI) using parasite challenged model in chickens. Protective sub-libraries were selected for the next round of screening until individual protective clones were obtained, which were further sequenced and analyzed. Adopting the Gateway technology, a high-quality entry library was constructed, containing 9.2 × 10 6 clones with an average inserted fragments length of 1.63 kb. The expression library capacity was 2.32 × 10 7 colony-forming units (cfu) with an average inserted fragments length of 1.64 Kb. The expression library was screened using parasite challenged model in chickens. The screening yielded 6 immune protective genes including four novel protective genes of EmJS-1, EmRP, EmHP-1 and EmHP-2, and two known protective genes of EmSAG and EmCKRS. EmJS-1 is the selR domain-containing protein of E. maxima whose function is unknown. EmHP-1 and EmHP-2 are the hypothetical proteins of E. maxima. EmRP and EmSAG are rhomboid-like protein and surface antigen glycoproteins of E. maxima respectively, and involved in invasion of the parasite. Our results provide a cDNA expression library for further screening of T cell stimulating or inhibiting antigens of E. maxima. Moreover, our results provide six candidate protective antigens for developing new vaccines against E. maxima.
Visualizing the global secondary structure of a viral RNA genome with cryo-electron microscopy
Garmann, Rees F.; Gopal, Ajaykumar; Athavale, Shreyas S.; Knobler, Charles M.; Gelbart, William M.; Harvey, Stephen C.
2015-01-01
The lifecycle, and therefore the virulence, of single-stranded (ss)-RNA viruses is regulated not only by their particular protein gene products, but also by the secondary and tertiary structure of their genomes. The secondary structure of the entire genomic RNA of satellite tobacco mosaic virus (STMV) was recently determined by selective 2′-hydroxyl acylation analyzed by primer extension (SHAPE). The SHAPE analysis suggested a single highly extended secondary structure with much less branching than occurs in the ensemble of structures predicted by purely thermodynamic algorithms. Here we examine the solution-equilibrated STMV genome by direct visualization with cryo-electron microscopy (cryo-EM), using an RNA of similar length transcribed from the yeast genome as a control. The cryo-EM data reveal an ensemble of branching patterns that are collectively consistent with the SHAPE-derived secondary structure model. Thus, our results both elucidate the statistical nature of the secondary structure of large ss-RNAs and give visual support for modern RNA structure determination methods. Additionally, this work introduces cryo-EM as a means to distinguish between competing secondary structure models if the models differ significantly in terms of the number and/or length of branches. Furthermore, with the latest advances in cryo-EM technology, we suggest the possibility of developing methods that incorporate restraints from cryo-EM into the next generation of algorithms for the determination of RNA secondary and tertiary structures. PMID:25752599
Stepping strategies for regulating gait adaptability and stability.
Hak, Laura; Houdijk, Han; Steenbrink, Frans; Mert, Agali; van der Wurff, Peter; Beek, Peter J; van Dieën, Jaap H
2013-03-15
Besides a stable gait pattern, gait in daily life requires the capability to adapt this pattern in response to environmental conditions. The purpose of this study was to elucidate the anticipatory strategies used by able-bodied people to attain an adaptive gait pattern, and how these strategies interact with strategies used to maintain gait stability. Ten healthy subjects walked in a Computer Assisted Rehabilitation ENvironment (CAREN). To provoke an adaptive gait pattern, subjects had to hit virtual targets, with markers guided by their knees, while walking on a self-paced treadmill. The effects of walking with and without this task on walking speed, step length, step frequency, step width and the margins of stability (MoS) were assessed. Furthermore, these trials were performed with and without additional continuous ML platform translations. When an adaptive gait pattern was required, subjects decreased step length (p<0.01), tended to increase step width (p=0.074), and decreased walking speed while maintaining similar step frequency compared to unconstrained walking. These adaptations resulted in the preservation of equal MoS between trials, despite the disturbing influence of the gait adaptability task. When the gait adaptability task was combined with the balance perturbation subjects further decreased step length, as evidenced by a significant interaction between both manipulations (p=0.012). In conclusion, able-bodied people reduce step length and increase step width during walking conditions requiring a high level of both stability and adaptability. Although an increase in step frequency has previously been found to enhance stability, a faster movement, which would coincide with a higher step frequency, hampers accuracy and may consequently limit gait adaptability. Copyright © 2012 Elsevier Ltd. All rights reserved.
Clinical gait evaluation of patients with knee osteoarthritis.
Sun, Jun; Liu, Yancheng; Yan, Songhua; Cao, Guanglei; Wang, Shasha; Lester, D Kevin; Zhang, Kuan
2017-10-01
Knee osteoarthritis (KOA) is the most common osteoarthritis in lower limbs, and gait measurement is important to evaluate walking function of KOA patients before and after treatment. The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3) is a portable gait analysis system to evaluate gaits. This study is to evaluate the accuracy and reliability of IDEEA3 for gait measurement of KOA patients. Meanwhile, gait differences between KOA patients and healthy subjects are examined. Twelve healthy volunteers were recruited for measurement comparison of gait cycle (GC), cadence, step length, velocity and step counts between a motion analysis system and a high-speed camera (GoPro Hero3). Twenty-three KOA patients were recruited for measurement comparison of former five parameters between GoPro Hero3 and IDEEA3. Paired t-test, Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC) were used for data analysis. All p-values of paired t-tests for GC, cadence, step length and velocity were greater than 0.05 while all CCC and ICC results were above 0.95. The measurements of GC, cadence, step length, velocity and step counts by motion analysis system are highly consistent with the measurements by GoPro Hero3. The measurements of former parameters by GoPro Hero3 are not statistically different from the measurements by IDEEA3. IDEEA3 can be effectively used for the measurement of GC, cadence, step length, velocity and step counts in KOA patients. The KOA patients walk with longer GC, lower cadence, shorter step length and slower speed compared with healthy subjects in natural speed with flat shoes. Copyright © 2017 Elsevier B.V. All rights reserved.
Barone, V; Verdini, F; Burattini, L; Di Nardo, F; Fioretti, S
2016-03-01
A markerless low cost prototype has been developed for the determination of some spatio-temporal parameters of human gait: step-length, step-width and cadence have been considered. Only a smartphone and a high-definition webcam have been used. The signals obtained by the accelerometer embedded in the smartphone are used to recognize the heel strike events, while the feet positions are calculated through image processing of the webcam stream. Step length and width are computed during gait trials on a treadmill at various speeds (3, 4 and 5 km/h). Six subjects have been tested for a total of 504 steps. Results were compared with those obtained by a stereo-photogrammetric system (Elite, BTS Engineering). The maximum average errors were 3.7 cm (5.36%) for the right step length and 1.63 cm (15.16%) for the right step width at 5 km/h. The maximum average error for step duration was 0.02 s (1.69%) at 5 km/h for the right steps. The system is characterized by a very high level of automation that allows its use by non-expert users in non-structured environments. A low cost system able to automatically provide a reliable and repeatable evaluation of some gait events and parameters during treadmill walking, is relevant also from a clinical point of view because it allows the analysis of hundreds of steps and consequently an analysis of their variability. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
FragFit: a web-application for interactive modeling of protein segments into cryo-EM density maps.
Tiemann, Johanna K S; Rose, Alexander S; Ismer, Jochen; Darvish, Mitra D; Hilal, Tarek; Spahn, Christian M T; Hildebrand, Peter W
2018-05-21
Cryo-electron microscopy (cryo-EM) is a standard method to determine the three-dimensional structures of molecular complexes. However, easy to use tools for modeling of protein segments into cryo-EM maps are sparse. Here, we present the FragFit web-application, a web server for interactive modeling of segments of up to 35 amino acids length into cryo-EM density maps. The fragments are provided by a regularly updated database containing at the moment about 1 billion entries extracted from PDB structures and can be readily integrated into a protein structure. Fragments are selected based on geometric criteria, sequence similarity and fit into a given cryo-EM density map. Web-based molecular visualization with the NGL Viewer allows interactive selection of fragments. The FragFit web-application, accessible at http://proteinformatics.de/FragFit, is free and open to all users, without any login requirements.
Mechanisms for regulating step length while running towards and over an obstacle.
Larsen, Roxanne J; Jackson, William H; Schmitt, Daniel
2016-10-01
The ability to run across uneven terrain with continuous stable movement is critical to the safety and efficiency of a runner. Successful step-to-step stabilization while running may be mediated by minor adjustments to a few key parameters (e.g., leg stiffness, step length, foot strike pattern). However, it is not known to what degree runners in relatively natural settings (e.g., trails, paved road, curbs) use the same strategies across multiple steps. This study investigates how three readily measurable running parameters - step length, foot placement, and foot strike pattern - are adjusted in response to encountering a typical urban obstacle - a sidewalk curb. Thirteen subjects were video-recorded as they ran at self-selected slow and fast paces. Runners targeted a specific distance before the curb for foot placement, and lengthened their step over the curb (p<0.0001) regardless of where the step over the curb was initiated. These strategies of adaptive locomotion disrupt step cycles temporarily, and may increase locomotor cost and muscle loading, but in the end assure dynamic stability and minimize the risk of injury over the duration of a run. Copyright © 2016 Elsevier B.V. All rights reserved.
Underwater Electromagnetic Sensor Networks—Part I: Link Characterization †
Quintana-Díaz, Gara; Mena-Rodríguez, Pablo; Pérez-Álvarez, Iván; Jiménez, Eugenio; Dorta-Naranjo, Blas-Pablo; Zazo, Santiago; Pérez, Marina; Quevedo, Eduardo; Cardona, Laura; Hernández, J. Joaquín
2017-01-01
Underwater Wireless Sensor Networks (UWSNs) using electromagnetic (EM) technology in marine shallow waters are examined, not just for environmental monitoring but for further interesting applications. Particularly, the use of EM waves is reconsidered in shallow waters due to the benefits offered in this context, where acoustic and optical technologies have serious disadvantages. Sea water scenario is a harsh environment for radiocommunications, and there is no standard model for the underwater EM channel. The high conductivity of sea water, the effect of seabed and the surface make the behaviour of the channel hard to predict. This justifies the need of link characterization as the first step to approach the development of EM underwater sensor networks. To obtain a reliable link model, measurements and simulations are required. The measuring setup for this purpose is explained and described, as well as the procedures used. Several antennas have been designed and tested in low frequency bands. Agreement between attenuation measurements and simulations at different distances was analysed and made possible the validation of simulation setups and the design of different communications layers of the system. This leads to the second step of this work, where data and routing protocols for the sensor network are examined. PMID:28106843
Underwater Electromagnetic Sensor Networks-Part I: Link Characterization.
Quintana-Díaz, Gara; Mena-Rodríguez, Pablo; Pérez-Álvarez, Iván; Jiménez, Eugenio; Dorta-Naranjo, Blas-Pablo; Zazo, Santiago; Pérez, Marina; Quevedo, Eduardo; Cardona, Laura; Hernández, J Joaquín
2017-01-19
Underwater Wireless Sensor Networks (UWSNs) using electromagnetic (EM) technology in marine shallow waters are examined, not just for environmental monitoring but for further interesting applications. Particularly, the use of EM waves is reconsidered in shallow waters due to the benefits offered in this context, where acoustic and optical technologies have serious disadvantages. Sea water scenario is a harsh environment for radiocommunications, and there is no standard model for the underwater EM channel. The high conductivity of sea water, the effect of seabed and the surface make the behaviour of the channel hard to predict. This justifies the need of link characterization as the first step to approach the development of EM underwater sensor networks. To obtain a reliable link model, measurements and simulations are required. The measuring setup for this purpose is explained and described, as well as the procedures used. Several antennas have been designed and tested in low frequency bands. Agreement between attenuation measurements and simulations at different distances was analysed and made possible the validation of simulation setups and the design of different communications layers of the system. This leads to the second step of this work, where data and routing protocols for the sensor network are examined.
Regier, Michael D; Moodie, Erica E M
2016-05-01
We propose an extension of the EM algorithm that exploits the common assumption of unique parameterization, corrects for biases due to missing data and measurement error, converges for the specified model when standard implementation of the EM algorithm has a low probability of convergence, and reduces a potentially complex algorithm into a sequence of smaller, simpler, self-contained EM algorithms. We use the theory surrounding the EM algorithm to derive the theoretical results of our proposal, showing that an optimal solution over the parameter space is obtained. A simulation study is used to explore the finite sample properties of the proposed extension when there is missing data and measurement error. We observe that partitioning the EM algorithm into simpler steps may provide better bias reduction in the estimation of model parameters. The ability to breakdown a complicated problem in to a series of simpler, more accessible problems will permit a broader implementation of the EM algorithm, permit the use of software packages that now implement and/or automate the EM algorithm, and make the EM algorithm more accessible to a wider and more general audience.
NASA Astrophysics Data System (ADS)
Humphries, Nicolas E.
2015-09-01
The comprehensive review of Lévy patterns observed in the moves and pauses of a vast array of organisms by Reynolds [1] makes clear a need to attempt to unify phenomena to understand how organism movement may have evolved. However, I would contend that the research on Lévy 'movement patterns' we detect in time series of animal movements has to a large extent been misunderstood. The statistical techniques, such as Maximum Likelihood Estimation, used to detect these patterns look only at the statistical distribution of move step-lengths and not at the actual pattern, or structure, of the movement path. The path structure is lost altogether when move step-lengths are sorted prior to analysis. Likewise, the simulated movement paths, with step-lengths drawn from a truncated power law distribution in order to test characteristics of the path, such as foraging efficiency, in no way match the actual paths, or trajectories, of real animals. These statistical distributions are, therefore, null models of searching or foraging activity. What has proved surprising about these step-length distributions is the extent to which they improve the efficiency of random searches over simple Brownian motion. It has been shown unequivocally that a power law distribution of move step lengths is more efficient, in terms of prey items located per unit distance travelled, than any other distribution of move step-lengths so far tested (up to 3 times better than Brownian), and over a range of prey field densities spanning more than 4 orders of magnitude [2].
Fischer, Lisa M; Woo, Michael Y; Lee, A Curtis; Wiss, Ray; Socransky, Steve; Frank, Jason R
2015-01-01
Emergency medicine point-of-care ultrasonography (EM-PoCUS) is a core competency for residents in the Royal College of Physicians and Surgeons of Canada and College of Family Physicians of Canada emergency medicine (EM) training programs. Although EM-PoCUS fellowships are currently offered in Canada, there is little consensus regarding what training should be included in a Canadian EM-PoCUS fellowship curriculum or how this contrasts with the training received in an EM residency.Objectives To conduct a systematic needs assessment of major stakeholders to define the essential elements necessary for a Canadian EM-PoCUS fellowship training curriculum. We carried out a national survey of experts in EM-PoCUS, EM residency program directors, and EM residents. Respondents were asked to identify competencies deemed either nonessential to EM practice, essential for general EM practice, essential for advanced EM practice, or essential for EM-PoCUS fellowship trained (‘‘expert’’) practice. The response rate was 81% (351 of 435). PoCUS was deemed essential to general EM practice for basic cardiac, aortic, trauma, and procedural imaging. PoCUS was deemed essential to advanced EM practice in undifferentiated symptomatology, advanced chest pathologies, and advanced procedural applications. Expert-level PoCUS competencies were identified for administrative, pediatric, and advanced gynecologic applications. Eighty-seven percent of respondents indicated that there was a need for EM-PoCUS fellowships, with an ideal length of 6 months. This is the first needs assessment of major stakeholders in Canada to identify competencies for expert training in EM-PoCUS. The competencies should form the basis for EM-PoCUS fellowship programs in Canada.
NASA Astrophysics Data System (ADS)
Gatto, Riccardo
2017-12-01
This article considers the random walk over Rp, with p ≥ 2, where a given particle starts at the origin and moves stepwise with uniformly distributed step directions and step lengths following a common distribution. Step directions and step lengths are independent. The case where the number of steps of the particle is fixed and the more general case where it follows an independent continuous time inhomogeneous counting process are considered. Saddlepoint approximations to the distribution of the distance from the position of the particle to the origin are provided. Despite the p-dimensional nature of the random walk, the computations of the saddlepoint approximations are one-dimensional and thus simple. Explicit formulae are derived with dimension p = 3: for uniformly and exponentially distributed step lengths, for fixed and for Poisson distributed number of steps. In these situations, the high accuracy of the saddlepoint approximations is illustrated by numerical comparisons with Monte Carlo simulation. Contribution to the "Topical Issue: Continuous Time Random Walk Still Trendy: Fifty-year History, Current State and Outlook", edited by Ryszard Kutner and Jaume Masoliver.
What is the Prevalence and Success of Remediation of Emergency Medicine Residents?
Silverberg, Mark; Weizberg, Moshe; Murano, Tiffany; Smith, Jessica L.; Burkhardt, John C.; Santen, Sally A.
2015-01-01
Introduction The primary objective of this study was to determine the prevalence of remediation, competency domains for remediation, the length, and success rates of remediation in emergency medicine (EM). Methods We developed the survey in Surveymonkey™ with attention to content and response process validity. EM program directors responded how many residents had been placed on remediation in the last three years. Details regarding the remediation were collected including indication, length and success. We reported descriptive data and estimated a multinomial logistic regression model. Results We obtained 126/158 responses (79.7%). Ninety percent of programs had at least one resident on remediation in the last three years. The prevalence of remediation was 4.4%. Indications for remediation ranged from difficulties with one core competency to all six competencies (mean 1.9). The most common were medical knowledge (MK) (63.1% of residents), patient care (46.6%) and professionalism (31.5%). Mean length of remediation was eight months (range 1–36 months). Successful remediation was 59.9% of remediated residents; 31.3% reported ongoing remediation. In 8.7%, remediation was deemed “unsuccessful.” Training year at time of identification for remediation (post-graduate year [PGY] 1), longer time spent in remediation, and concerns with practice-based learning (PBLI) and professionalism were found to have statistically significant association with unsuccessful remediation. Conclusion Remediation in EM residencies is common, with the most common areas being MK and patient care. The majority of residents are successfully remediated. PGY level, length of time spent in remediation, and the remediation of the competencies of PBLI and professionalism were associated with unsuccessful remediation. PMID:26594275
Bilateral step length estimation using a single inertial measurement unit attached to the pelvis
2012-01-01
Background The estimation of the spatio-temporal gait parameters is of primary importance in both physical activity monitoring and clinical contexts. A method for estimating step length bilaterally, during level walking, using a single inertial measurement unit (IMU) attached to the pelvis is proposed. In contrast to previous studies, based either on a simplified representation of the human gait mechanics or on a general linear regressive model, the proposed method estimates the step length directly from the integration of the acceleration along the direction of progression. Methods The IMU was placed at pelvis level fixed to the subject's belt on the right side. The method was validated using measurements from a stereo-photogrammetric system as a gold standard on nine subjects walking ten laps along a closed loop track of about 25 m, varying their speed. For each loop, only the IMU data recorded in a 4 m long portion of the track included in the calibrated volume of the SP system, were used for the analysis. The method takes advantage of the cyclic nature of gait and it requires an accurate determination of the foot contact instances. A combination of a Kalman filter and of an optimally filtered direct and reverse integration applied to the IMU signals formed a single novel method (Kalman and Optimally filtered Step length Estimation - KOSE method). A correction of the IMU displacement due to the pelvic rotation occurring in gait was implemented to estimate the step length and the traversed distance. Results The step length was estimated for all subjects with less than 3% error. Traversed distance was assessed with less than 2% error. Conclusions The proposed method provided estimates of step length and traversed distance more accurate than any other method applied to measurements obtained from a single IMU that can be found in the literature. In healthy subjects, it is reasonable to expect that, errors in traversed distance estimation during daily monitoring activity would be of the same order of magnitude of those presented. PMID:22316235
Mechanical and energetic consequences of rolling foot shape in human walking
Adamczyk, Peter G.; Kuo, Arthur D.
2013-01-01
SUMMARY During human walking, the center of pressure under the foot progresses forward smoothly during each step, creating a wheel-like motion between the leg and the ground. This rolling motion might appear to aid walking economy, but the mechanisms that may lead to such a benefit are unclear, as the leg is not literally a wheel. We propose that there is indeed a benefit, but less from rolling than from smoother transitions between pendulum-like stance legs. The velocity of the body center of mass (COM) must be redirected in that transition, and a longer foot reduces the work required for the redirection. Here we develop a dynamic walking model that predicts different effects from altering foot length as opposed to foot radius, and test it by attaching rigid, arc-like foot bottoms to humans walking with fixed ankles. The model suggests that smooth rolling is relatively insensitive to arc radius, whereas work for the step-to-step transition decreases approximately quadratically with foot length. We measured the separate effects of arc-foot length and radius on COM velocity fluctuations, work performed by the legs and metabolic cost. Experimental data (N=8) show that foot length indeed has much greater effect on both the mechanical work of the step-to-step transition (23% variation, P=0.04) and the overall energetic cost of walking (6%, P=0.03) than foot radius (no significant effect, P>0.05). We found the minimum metabolic energy cost for an arc foot length of approximately 29% of leg length, roughly comparable to human foot length. Our results suggest that the foot's apparently wheel-like action derives less benefit from rolling per se than from reduced work to redirect the body COM. PMID:23580717
Mechanical and energetic consequences of rolling foot shape in human walking.
Adamczyk, Peter G; Kuo, Arthur D
2013-07-15
During human walking, the center of pressure under the foot progresses forward smoothly during each step, creating a wheel-like motion between the leg and the ground. This rolling motion might appear to aid walking economy, but the mechanisms that may lead to such a benefit are unclear, as the leg is not literally a wheel. We propose that there is indeed a benefit, but less from rolling than from smoother transitions between pendulum-like stance legs. The velocity of the body center of mass (COM) must be redirected in that transition, and a longer foot reduces the work required for the redirection. Here we develop a dynamic walking model that predicts different effects from altering foot length as opposed to foot radius, and test it by attaching rigid, arc-like foot bottoms to humans walking with fixed ankles. The model suggests that smooth rolling is relatively insensitive to arc radius, whereas work for the step-to-step transition decreases approximately quadratically with foot length. We measured the separate effects of arc-foot length and radius on COM velocity fluctuations, work performed by the legs and metabolic cost. Experimental data (N=8) show that foot length indeed has much greater effect on both the mechanical work of the step-to-step transition (23% variation, P=0.04) and the overall energetic cost of walking (6%, P=0.03) than foot radius (no significant effect, P>0.05). We found the minimum metabolic energy cost for an arc foot length of approximately 29% of leg length, roughly comparable to human foot length. Our results suggest that the foot's apparently wheel-like action derives less benefit from rolling per se than from reduced work to redirect the body COM.
NASA Astrophysics Data System (ADS)
Koziel, Slawomir; Bekasiewicz, Adrian
2018-02-01
In this article, a simple yet efficient and reliable technique for fully automated multi-objective design optimization of antenna structures using sequential domain patching (SDP) is discussed. The optimization procedure according to SDP is a two-step process: (i) obtaining the initial set of Pareto-optimal designs representing the best possible trade-offs between considered conflicting objectives, and (ii) Pareto set refinement for yielding the optimal designs at the high-fidelity electromagnetic (EM) simulation model level. For the sake of computational efficiency, the first step is realized at the level of a low-fidelity (coarse-discretization) EM model by sequential construction and relocation of small design space segments (patches) in order to create a path connecting the extreme Pareto front designs obtained beforehand. The second stage involves response correction techniques and local response surface approximation models constructed by reusing EM simulation data acquired in the first step. A major contribution of this work is an automated procedure for determining the patch dimensions. It allows for appropriate selection of the number of patches for each geometry variable so as to ensure reliability of the optimization process while maintaining its low cost. The importance of this procedure is demonstrated by comparing it with uniform patch dimensions.
Does EMS Perceived Anatomic Injury Predict Trauma Center Need?
Lerner, E. Brooke; Roberts, Jennifer; Guse, Clare E.; Shah, Manish N.; Swor, Robert; Cushman, Jeremy T.; Blatt, Alan; Jurkovich, Gregory J.; Brasel, Karen
2013-01-01
Objective Our objective was to determine the predictive value of the anatomic step of the 2011 Field Triage Decision Scheme for identifying trauma center need. Methods EMS providers caring for injured adults transported to regional trauma centers in 3 midsized communities were interviewed over two years. Patients were included, regardless of injury severity, if they were at least 18 years old and were transported by EMS with a mechanism of injury that was an assault, motor vehicle or motorcycle crash, fall, or pedestrian or bicyclist struck. The interview was conducted upon ED arrival and collected physiologic condition and anatomic injury data. Patients who met the physiologic criteria were excluded. Trauma center need was defined as non-orthopedic surgery within 24 hours, intensive care unit admission, or death prior to hospital discharge. Data were analyzed by calculating descriptive statistics including positive likelihood ratios (+LR) with 95% confidence intervals. Results 11,892 interviews were conducted. One was excluded because of missing outcome data and 1,274 were excluded because they met the physiologic step. EMS providers identified 1,167 cases that met the anatomic criteria, of which 307 (26%) needed the resources of a trauma center (38% sensitivity, 91% specificity, +LR 4.4; CI: 3.9 - 4.9). Criteria with a +LR ≥5 were flail chest (9.0; CI: 4.1 - 19.4), paralysis (6.8; CI: 4.2 - 11.2), two or more long bone fractures (6.3; CI: 4.5 - 8.9), and amputation (6.1; CI: 1.5 - 24.4). Criteria with a +LR >2 and <5 were penetrating injury (4.8; CI: 4.2 - 5.6), and skull fracture (4.8; CI: 3.0 - 7.7). Only pelvic fracture (1.9; CI: 1.3 - 2.9) had a +LR less than 2. Conclusions The anatomic step of the Field Triage Guidelines as determined by EMS providers is a reasonable tool for determining trauma center need. Use of EMS perceived pelvic fracture as an indicator for trauma center need should be re-evaluated. PMID:23627418
Elek, J; Prochazka, A; Hulliger, M; Vincent, S
1990-01-01
1. It has been claimed that stretch in the non-contractile (extramysial) portion of muscles is substantial, and may produce large discrepancies between the origin-to-insertion muscle length and the internal length variations 'seen' by muscle spindle endings. 2. In eight pentobarbitone-anaesthetized cats, we estimated stretch in the extramysial portion of medial gastrocnemius (MG) muscle with a method similar to the spindle null technique. 3. Length variations of MG previously monitored in a normal step cycle were reproduced with a computer-controlled length servo. The responses of test MG spindle endings were monitored in dorsal root filaments. Distributed stimulation of ventral root filaments, rate-modulated by the step-cycle EMG envelope, served to reproduce step-cycle forces. The filaments were selected so as to have no fusimotor action on the test spindle. 4. Spindle responses in active cycles were compared with those in passive cycles (stretch, but no distributed stimulation). In some cases concomitant tonic fusimotor stimulation was used to maintain spindle responsiveness throughout the cycle, both in active and passive trials. Generally, small discrepancies in spindle firing were seen. The passive trials were now repeated, with iterative adjustments of the length function, until the response matched the spindle firing profile in the active trial. The spindle 'saw' the same internal length change in the final passive trial as in the active trial. Any difference between the corresponding length profiles was attributed to extramysial displacement. 5. Extramysial displacement estimated in this was was maximal at short mean muscle lengths, reaching about 0.5 mm in a typical step cycle (force rising from 0 to 10 N). At longer mean muscle lengths where muscle force rose from say 2 to 12 N in the cycle, extramysial displacement was in the range 0.2-0.4 mm. 6. Except at very short lengths, the displacement was probably mainly tendinous. On this assumption, our results suggested that the stiffness of the MG tendinous compartment was force related, and about double that of cat soleus muscle at any given force. Calculations indicated that though the stretch was small, the MG tendon would store and release enough strain energy per cycle to contribute significantly to the E3 phase of the step cycle. The discrepancies in spindle firing were generally quite subtle, so we reject the claim that extramysial stretch poses a serious difficulty for inferences about fusimotion from chronic spindle afferent recordings. PMID:2148952
Lauzière, Séléna; Miéville, Carole; Betschart, Martina; Duclos, Cyril; Aissaoui, Rachid; Nadeau, Sylvie
2014-10-01
To assess plantarflexion moment and hip joint moment after-effects following walking on a split-belt treadmill in healthy individuals and individuals post-stroke. Cross-sectional study. Ten healthy individuals (mean age 57.6 years (standard deviation; SD 17.2)) and twenty individuals post-stroke (mean age 49.3 years (SD 13.2)). Participants walked on an instrumented split-belt treadmill under 3 gait periods: i) baseline (tied-belt); ii) adaptation (split-belt); and iii) post-adaptation (tied-belt). Participants post-stroke performed the protocol with the paretic and nonparetic leg on the faster belt when belts were split. Kinematic data were recorded with the Optotrak system and ground reaction forces were collected via the instrumented split-belt treadmill. In both groups, the fast plantarflexion moment was reduced and the slow plantarflexion moment was increased from mid-stance to toe-off in the post-adaptation period. Significant relationships were found between the plantarflexion moment and contralateral step length. Split-belt treadmills could be useful for restoring step length symmetry in individuals post-stroke who present with a longer paretic step length because the use of this type of intervention increases paretic plantarflexion moments. This intervention might be less recommended for individuals post-stroke with a shorter paretic step length because it reduces the paretic plantarflexion moment.
2011-03-01
following: disturbance of sensitive environments (including wildlife); dredging up potentially contaminated sediments; physical contact with UXO; damaging or...is discussed below. 2.1.1 EM61 System and Sensors The EM61 is a high-resolution time-domain electromagnetic metal detector that is capable of...the position of the tow boat and then try to extrapolate the position of the detector based on cable length and GPS heading. In most cases, the
Manson, William C; Ryan, James G; Ladner, Heidi; Gupta, Sanjey
2011-01-01
Introduction We compared the immediate cosmetic outcome of metallic foreign-body removal by emergency medicine (EM) residents with ultrasound guidance and conventional radiography. Methods This single-blinded, randomized, crossover study evaluated the ability of EM residents to remove metallic pins embedded in pigs' feet. Before the experiment, we embedded 1.5-cm metallic pins into numbered pigs' feet. We randomly assigned 14 EM residents to use either ultrasound or radiography to help remove the foreign body. Residents had minimal ultrasound experience. After a brief lecture, we provided residents with a scalpel, laceration kit, a bedside portable ultrasound machine, nipple markers, paper clips, a dedicated radiograph technician, and radiograph machine 20 feet away. After removal, 3 board-certified emergency physicians, who were blinded to the study group, evaluated the soft-tissue model by using a standardized form. They recorded incision length and cosmetic appearance on the Visual Analog Scale. Results In total, 28 foreign bodies were removed. No significant difference in the time of removal (P = 0.12), cosmetic appearance (P = 0.96), or incision length (P = 0.76) was found. Conclusion This study showed no difference between bedside ultrasound and radiography in assisting EM residents with metallic foreign-body removal from soft tissue. No significant difference was found in removal time or cosmetic outcome when comparing ultrasound with radiography. PMID:22224139
A kinematic analysis of the rapid step test in balance-impaired and unimpaired older women.
Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B
2007-04-01
Little is known about the kinematic and kinetic determinants that might explain age and balance-impairment alterations in the results of volitional stepping performance tests. Maximal unipedal stance time (UST) was used to distinguish "balance-impaired" old (BI, UST<10s, N=15, mean age=76 years) from unimpaired old (O, UST>30s, N=12, mean age=71 years) before they and healthy young females (Y, UST>30s, N=13, mean age=23 years) performed the rapid step test (RST). The RST evaluates the time required to take volitional front, side, and back steps of at least 80% maximum step length in response to verbal commands. Kinematic and kinetic data were recorded during the RST. The results indicate that the initiation phase of the step was the major source of age- and balance impairment-related delays. The delays in BI were primarily caused by increased postural adjustments prior to step initiation, as measured by center-of-pressure (COP) path length (p<0.003). The Step landing phase showed similar, but non-significant, temporal trends. Step length and peak center-of-mass (COM) deceleration during the Step-Out landing decreased in O by 18% (p=0.0002) and 24% (p=0.001), respectively, and a further 12% (p=0.04) and 18% (p=0.08) in BI. We conclude that the delay in BI step initiation was due to the increase in their postural adjustments prior to step initiation.
Efficient sequential and parallel algorithms for finding edit distance based motifs.
Pal, Soumitra; Xiao, Peng; Rajasekaran, Sanguthevar
2016-08-18
Motif search is an important step in extracting meaningful patterns from biological data. The general problem of motif search is intractable and there is a pressing need to develop efficient, exact and approximation algorithms to solve this problem. In this paper, we present several novel, exact, sequential and parallel algorithms for solving the (l,d) Edit-distance-based Motif Search (EMS) problem: given two integers l,d and n biological strings, find all strings of length l that appear in each input string with atmost d errors of types substitution, insertion and deletion. One popular technique to solve the problem is to explore for each input string the set of all possible l-mers that belong to the d-neighborhood of any substring of the input string and output those which are common for all input strings. We introduce a novel and provably efficient neighborhood exploration technique. We show that it is enough to consider the candidates in neighborhood which are at a distance exactly d. We compactly represent these candidate motifs using wildcard characters and efficiently explore them with very few repetitions. Our sequential algorithm uses a trie based data structure to efficiently store and sort the candidate motifs. Our parallel algorithm in a multi-core shared memory setting uses arrays for storing and a novel modification of radix-sort for sorting the candidate motifs. The algorithms for EMS are customarily evaluated on several challenging instances such as (8,1), (12,2), (16,3), (20,4), and so on. The best previously known algorithm, EMS1, is sequential and in estimated 3 days solves up to instance (16,3). Our sequential algorithms are more than 20 times faster on (16,3). On other hard instances such as (9,2), (11,3), (13,4), our algorithms are much faster. Our parallel algorithm has more than 600 % scaling performance while using 16 threads. Our algorithms have pushed up the state-of-the-art of EMS solvers and we believe that the techniques introduced in this paper are also applicable to other motif search problems such as Planted Motif Search (PMS) and Simple Motif Search (SMS).
Venkadesaperumal, Gopu; Amaresan, Natrajan; Kumar, Krishna
2014-01-01
Twenty four bacterial strains from four different regions of mud volcano and lime cave were isolated to estimate their diversity, plant growth promoting and biocontrol activities to use them as inoculant strains in the fields. An excellent antagonistic effect against four plant pathogens and plant growth promoting properties such as IAA production, HCN production, phosphate solubilization, siderophore production, starch hydrolysis and hydrolytic enzymes syntheses were identified in OM5 (Pantoea agglomerans) and EM9 (Exiguobacterium sp.) of 24 studied isolates. Seeds (Chili and tomato) inoculation with plant growth promoting strains resulted in increased percentage of seedling emergence, root length and plant weight. Results indicated that co-inoculation gave a more pronounced effects on seedling emergence, secondary root numbers, primary root length and stem length, while inoculation by alone isolate showed a lower effect. Our results suggest that the mixed inocula of OM5 and EM9 strains as biofertilizers could significantly increase the production of food crops in Andaman archipelago by means of sustainable and organic agricultural system. PMID:25763031
Venkadesaperumal, Gopu; Amaresan, Natrajan; Kumar, Krishna
2014-01-01
Twenty four bacterial strains from four different regions of mud volcano and lime cave were isolated to estimate their diversity, plant growth promoting and biocontrol activities to use them as inoculant strains in the fields. An excellent antagonistic effect against four plant pathogens and plant growth promoting properties such as IAA production, HCN production, phosphate solubilization, siderophore production, starch hydrolysis and hydrolytic enzymes syntheses were identified in OM5 (Pantoea agglomerans) and EM9 (Exiguobacterium sp.) of 24 studied isolates. Seeds (Chili and tomato) inoculation with plant growth promoting strains resulted in increased percentage of seedling emergence, root length and plant weight. Results indicated that co-inoculation gave a more pronounced effects on seedling emergence, secondary root numbers, primary root length and stem length, while inoculation by alone isolate showed a lower effect. Our results suggest that the mixed inocula of OM5 and EM9 strains as biofertilizers could significantly increase the production of food crops in Andaman archipelago by means of sustainable and organic agricultural system.
NASA Astrophysics Data System (ADS)
Rejiba, F.; Sagnard, F.; Schamper, C.
2011-07-01
Time domain reflectometry (TDR) is a proven, nondestructive method for the measurement of the permittivity and electrical conductivity of soils, using electromagnetic (EM) waves. Standard interpretation of TDR data leads to the estimation of the soil's equivalent electromagnetic properties since the wavelengths associated with the source signal are considerably greater than the microstructure of the soil. The aforementioned approximation tends to hide an important issue: the influence of the microstructure and phase configuration in the generation of a polarized electric field, which is complicated because of the presence of numerous length scales. In this paper, the influence of the microstructural distribution of each phase on the TDR signal has been studied. We propose a two-step EM modeling technique at a microscale range (?): first, we define an equivalent grain including a thin shell of free water, and second, we solve Maxwell's equations over the discretized, statistically distributed triphasic porous medium. Modeling of the TDR probe with the soil sample was performed using a three-dimensional finite difference time domain scheme. The effectiveness of this hybrid homogenization approach is tested on unsaturated Nemours sand with narrow granulometric fractions. The comparisons made between numerical and experimental results are promising, despite significant assumptions concerning (1) the TDR probe head and the coaxial cable and (2) the assumed effective medium theory homogenization associated with the electromagnetic processes arising locally between the liquid and solid phases at the grain scale.
ERIC Educational Resources Information Center
Buschauer, Robert
2014-01-01
In undergraduate E&M courses the magnetic field due to a finite length, current-carrying wire can be calculated using the Biot-Savart law. However, to the author's knowledge, no textbook presents the calculation of this field using the Ampere-Maxwell law: ?B [multiplied by] dl = µ[subscript 0] (I + e[subscript 0] dF/dt) [multiplied by] 1
Estimating physical activity in children: impact of pedometer wear time and metric.
Laurson, Kelly R; Welk, Gregory J; Eisenmann, Joey C
2015-01-01
The purpose of this study was to provide a practical demonstration of the impact of monitoring frame and metric when assessing pedometer-determined physical activity (PA) in youth. Children (N = 1111) were asked to wear pedometers over a 7-day period during which time worn and steps were recorded each day. Varying data-exclusion criteria were used to demonstrate changes in estimates of PA. Steps were expressed using several metrics and criteria, and construct validity was demonstrated via correlations with adiposity. Meaningful fluctuations in average steps per day and percentage meeting PA recommendations were apparent when different criteria were used. Children who wore the pedometer longer appeared more active, with each minute the pedometer was worn each day accounting for an approximate increase of 11 and 8 steps for boys and girls, respectively (P < .05). Using more restrictive exclusion criteria led to stronger correlations between indices of steps per day, steps per minute, steps per leg length, steps per minute per leg length, and obesity. Wear time has a meaningful impact on estimates of PA. This should be considered when determining exclusion criteria and making comparisons between studies. Results also suggest that incorporating wear time per day and leg length into the metric may increase validity of PA estimates.
Effects of gyrokinesis exercise on the gait pattern of female patients with chronic low back pain
Seo, Kook-Eun; Park, Tae-Jin
2016-01-01
[Purpose] The purpose of the present study was to use kinematic variables to identify the effects of 8/weeks’ performance of a gyrokinesis exercise on the gait pattern of females with chronic low back pain. [Subjects] The subjects of the present study were females in their late 20s to mid 30s who were chronic back pain patients. [Methods] A 3-D motion analysis system was used to measure the changes in their gait patterns between pre and post-gyrokintic exercise. The SPSS 21.0 statistics program was used to perform the paired t-test, to compare the gait patterns of pre-post-gyrokinesis exercise. [Results] In the gait analysis, pre-post-gyrokinesis exercise gait patterns showed statistically significant differences in right and left step length, stride length, right-left step widths, and stride speed. [Conclusion] Gait pattern analysis revealed increases in step length, stride length, and stride speed along with a decrease in step width after 8 weeks of gyrokinesis exercise, demonstrating it improved gait pattern. PMID:27065537
Trukhmanov, I M; Suslova, G A; Ponomarenko, G N
This paper is devoted to the characteristic of the informative value of the functional step test with the application of the heel cushions in the children for the purpose of differential diagnostics of anatomic and functional differences in the length of the lower extremities. A total of 85 schoolchildren with different length of the lower extremities have been examined. The comparative evaluation of the results of clinical and instrumental examinations was undertaken. The data obtained with the help of the functional step test give evidence of its very high sensitivity, specificity, and clinical significant as a tool for the examination of the children with different length of the low extremities. It is concluded that the test is one of the most informative predictors of the effectiveness of rehabilitation in the children with different length of the lower extremities.
Estimation for general birth-death processes
Crawford, Forrest W.; Minin, Vladimir N.; Suchard, Marc A.
2013-01-01
Birth-death processes (BDPs) are continuous-time Markov chains that track the number of “particles” in a system over time. While widely used in population biology, genetics and ecology, statistical inference of the instantaneous particle birth and death rates remains largely limited to restrictive linear BDPs in which per-particle birth and death rates are constant. Researchers often observe the number of particles at discrete times, necessitating data augmentation procedures such as expectation-maximization (EM) to find maximum likelihood estimates. For BDPs on finite state-spaces, there are powerful matrix methods for computing the conditional expectations needed for the E-step of the EM algorithm. For BDPs on infinite state-spaces, closed-form solutions for the E-step are available for some linear models, but most previous work has resorted to time-consuming simulation. Remarkably, we show that the E-step conditional expectations can be expressed as convolutions of computable transition probabilities for any general BDP with arbitrary rates. This important observation, along with a convenient continued fraction representation of the Laplace transforms of the transition probabilities, allows for novel and efficient computation of the conditional expectations for all BDPs, eliminating the need for truncation of the state-space or costly simulation. We use this insight to derive EM algorithms that yield maximum likelihood estimation for general BDPs characterized by various rate models, including generalized linear models. We show that our Laplace convolution technique outperforms competing methods when they are available and demonstrate a technique to accelerate EM algorithm convergence. We validate our approach using synthetic data and then apply our methods to cancer cell growth and estimation of mutation parameters in microsatellite evolution. PMID:25328261
Estimation for general birth-death processes.
Crawford, Forrest W; Minin, Vladimir N; Suchard, Marc A
2014-04-01
Birth-death processes (BDPs) are continuous-time Markov chains that track the number of "particles" in a system over time. While widely used in population biology, genetics and ecology, statistical inference of the instantaneous particle birth and death rates remains largely limited to restrictive linear BDPs in which per-particle birth and death rates are constant. Researchers often observe the number of particles at discrete times, necessitating data augmentation procedures such as expectation-maximization (EM) to find maximum likelihood estimates. For BDPs on finite state-spaces, there are powerful matrix methods for computing the conditional expectations needed for the E-step of the EM algorithm. For BDPs on infinite state-spaces, closed-form solutions for the E-step are available for some linear models, but most previous work has resorted to time-consuming simulation. Remarkably, we show that the E-step conditional expectations can be expressed as convolutions of computable transition probabilities for any general BDP with arbitrary rates. This important observation, along with a convenient continued fraction representation of the Laplace transforms of the transition probabilities, allows for novel and efficient computation of the conditional expectations for all BDPs, eliminating the need for truncation of the state-space or costly simulation. We use this insight to derive EM algorithms that yield maximum likelihood estimation for general BDPs characterized by various rate models, including generalized linear models. We show that our Laplace convolution technique outperforms competing methods when they are available and demonstrate a technique to accelerate EM algorithm convergence. We validate our approach using synthetic data and then apply our methods to cancer cell growth and estimation of mutation parameters in microsatellite evolution.
Predicting severe injury using vehicle telemetry data.
Ayoung-Chee, Patricia; Mack, Christopher D; Kaufman, Robert; Bulger, Eileen
2013-01-01
In 2010, the National Highway Traffic Safety Administration standardized collision data collected by event data recorders, which may help determine appropriate emergency medical service (EMS) response. Previous models (e.g., General Motors ) predict severe injury (Injury Severity Score [ISS] > 15) using occupant demographics and collision data. Occupant information is not automatically available, and 12% of calls from advanced automatic collision notification providers are unanswered. To better inform EMS triage, our goal was to create a predictive model only using vehicle collision data. Using the National Automotive Sampling System Crashworthiness Data System data set, we included front-seat occupants in late-model vehicles (2000 and later) in nonrollover and rollover crashes in years 2000 to 2010. Telematic (change in velocity, direction of force, seat belt use, vehicle type and curb weight, as well as multiple impact) and nontelematic variables (maximum intrusion, narrow impact, and passenger ejection) were included. Missing data were multiply imputed. The University of Washington model was tested to predict severe injury before application of guidelines (Step 0) and for occupants who did not meet Steps 1 and 2 criteria (Step 3) of the Centers for Disease Control and Prevention Field Triage Guidelines. A probability threshold of 20% was chosen in accordance with Centers for Disease Control and Prevention recommendations. There were 28,633 crashes, involving 33,956 vehicles and 52,033 occupants, of whom 9.9% had severe injury. At Step 0, the University of Washington model sensitivity was 40.0% and positive predictive value (PPV) was 20.7%. At Step 3, the sensitivity was 32.3 % and PPV was 10.1%. Model analysis excluding nontelematic variables decreased sensitivity and PPV. The sensitivity of the re-created General Motors model was 38.5% at Step 0 and 28.1% at Step 3. We designed a model using only vehicle collision data that was predictive of severe injury at collision notification and in the field and was comparable with an existing model. These models demonstrate the potential use of advanced automatic collision notification in planning EMS response. Prognostic study, level II.
Cai, Xi; Han, Guang; Song, Xin; Wang, Jinkuan
2017-11-01
single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc. single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc.
Thies, Sibylle B; Richardson, James K; Demott, Trina; Ashton-Miller, James A
2005-08-01
Patients with peripheral neuropathy (PN) report greater difficulty walking on irregular surfaces with low light (IL) than on flat surfaces with regular lighting (FR). We tested the primary hypothesis that older PN patients would demonstrate greater step width and step width variability under IL conditions than under FR conditions. Forty-two subjects (22 male, 20 female: mean +/- S.D.: 64.7 +/- 9.8 years) with PN underwent history, physical examination, and electrodiagnostic testing. Subjects were asked to walk 10 m at a comfortable speed while kinematic and force data were measured at 100 Hz using optoelectronic markers and foot switches. Ten trials were conducted under both IL and FR conditions. Step width, time, length, and speed were calculated with a MATLAB algorithm, with the standard deviation serving as the measure of variability. The results showed that under IL, as compared to FR, conditions subjects demonstrated greater step width (197.1 +/- 40.8 mm versus 180.5 +/- 32.4 mm; P < 0.001) and step width variability (40.4 +/- 9.0 mm versus 34.5 +/- 8.4 mm; P < 0.001), step time and its variability (P < 0.001 and P = 0.003, respectively), and step length variability (P < 0.001). Average step length and gait speed decreased under IL conditions (P < 0.001 for both). Step width variability and step time variability correlated best under IL conditions with a clinical measure of PN severity and fall history, respectively. We conclude that IL conditions cause PN patients to increase the variability of their step width and other gait parameters.
Gait parameter and event estimation using smartphones.
Pepa, Lucia; Verdini, Federica; Spalazzi, Luca
2017-09-01
The use of smartphones can greatly help for gait parameters estimation during daily living, but its accuracy needs a deeper evaluation against a gold standard. The objective of the paper is a step-by-step assessment of smartphone performance in heel strike, step count, step period, and step length estimation. The influence of smartphone placement and orientation on estimation performance is evaluated as well. This work relies on a smartphone app developed to acquire, process, and store inertial sensor data and rotation matrices about device position. Smartphone alignment was evaluated by expressing the acceleration vector in three reference frames. Two smartphone placements were tested. Three methods for heel strike detection were considered. On the basis of estimated heel strikes, step count is performed, step period is obtained, and the inverted pendulum model is applied for step length estimation. Pearson correlation coefficient, absolute and relative errors, ANOVA, and Bland-Altman limits of agreement were used to compare smartphone estimation with stereophotogrammetry on eleven healthy subjects. High correlations were found between smartphone and stereophotogrammetric measures: up to 0.93 for step count, to 0.99 for heel strike, 0.96 for step period, and 0.92 for step length. Error ranges are comparable to those in the literature. Smartphone placement did not affect the performance. The major influence of acceleration reference frames and heel strike detection method was found in step count. This study provides detailed information about expected accuracy when smartphone is used as a gait monitoring tool. The obtained results encourage real life applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Bezodis, Ian N; Kerwin, David G; Cooper, Stephen-Mark; Salo, Aki I T
2017-11-15
To understand how training periodization influences sprint performance and key step characteristics over an extended training period in an elite sprint training group. Four sprinters were studied during five months of training. Step velocities, step lengths and step frequencies were measured from video of the maximum velocity phase of training sprints. Bootstrapped mean values were calculated for each athlete for each session and 139 within-athlete, between-session comparisons were made with a repeated measures ANOVA. As training progressed, a link in the changes in velocity and step frequency was maintained. There were 71 between-session comparisons with a change in step velocity yielding at least a large effect size (>1.2), of which 73% had a correspondingly large change in step frequency in the same direction. Within-athlete mean session step length remained relatively constant throughout. Reductions in step velocity and frequency occurred during training phases of high volume lifting and running, with subsequent increases in step velocity and frequency happening during phases of low volume lifting and high intensity sprint work. The importance of step frequency over step length to the changes in performance within a training year was clearly evident for the sprinters studied. Understanding the magnitudes and timings of these changes in relation to the training program is important for coaches and athletes. The underpinning neuro-muscular mechanisms require further investigation, but are likely explained by an increase in force producing capability followed by an increase in the ability to produce that force rapidly.
The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners
Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda
2014-01-01
Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835
Hyodo, Masaki; Saito, Mayumi; Ushiba, Junichi; Tomita, Yutaka; Minami, Mihoko; Masakado, Yoshihisa
2012-07-01
Compensatory steps are essential for preventing falls following perturbations. This study aimed to explore age-related changes in compensatory steps to unilateral perturbations, specifically in terms of whether anticipatory postural adjustments (APAs) play a role in stabilizing lateral balance. Five young and five elderly male adults participated. The split-belt treadmill was used to provide bi- and unilateral perturbations, as forward or backward transitions, applied 10 times in random order. Backward steps evoked by unilateral forward perturbations were evaluated. We measured temporal characteristics, mediolateral (ML) center of mass (COM) motion, and ML step length of compensatory steps. Compensatory steps to unexpected perturbations showed delayed onset of foot-off (FO) and expanded lateral swing length in elderly compared to young subjects. Differences in COM motions and step width arose related to APAs. Elderly subjects showing APAs exhibited no significant differences in ML COM, ML COM velocity, or ML swing length compared to young subjects. However, elderly subjects without APAs showed significant changes toward instability in these parameters. The fact that APAs play a notable role, particularly in the elderly, in stability offers a new insight into preventing falls. However, APAs occurred in 29% of the steps of young and 35% of the steps of elderly subjects. If the occurrence of APAs in elderly people in response to compensatory steps was more frequent, fall risk would be reduced. Further studies, particularly into APA frequency, might contribute to improved intervention to prevent falls. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Han, Y.; Misra, S.
2018-04-01
Multi-frequency measurement of a dispersive electromagnetic (EM) property, such as electrical conductivity, dielectric permittivity, or magnetic permeability, is commonly analyzed for purposes of material characterization. Such an analysis requires inversion of the multi-frequency measurement based on a specific relaxation model, such as Cole-Cole model or Pelton's model. We develop a unified inversion scheme that can be coupled to various type of relaxation models to independently process multi-frequency measurement of varied EM properties for purposes of improved EM-based geomaterial characterization. The proposed inversion scheme is firstly tested in few synthetic cases in which different relaxation models are coupled into the inversion scheme and then applied to multi-frequency complex conductivity, complex resistivity, complex permittivity, and complex impedance measurements. The method estimates up to seven relaxation-model parameters exhibiting convergence and accuracy for random initializations of the relaxation-model parameters within up to 3-orders of magnitude variation around the true parameter values. The proposed inversion method implements a bounded Levenberg algorithm with tuning initial values of damping parameter and its iterative adjustment factor, which are fixed in all the cases shown in this paper and irrespective of the type of measured EM property and the type of relaxation model. Notably, jump-out step and jump-back-in step are implemented as automated methods in the inversion scheme to prevent the inversion from getting trapped around local minima and to honor physical bounds of model parameters. The proposed inversion scheme can be easily used to process various types of EM measurements without major changes to the inversion scheme.
The network construction of CSELF for earthquake monitoring and its preliminary observation
NASA Astrophysics Data System (ADS)
Tang, J.; Zhao, G.; Chen, X.; Bing, H.; Wang, L.; Zhan, Y.; Xiao, Q.; Dong, Z.
2017-12-01
The Electromagnetic (EM) anomaly in short-term earthquake precursory is most sensitive physical phenomena. Scientists believe that EM monitoring for earthquake is one of the most promising means of forecasting. However, existing ground-base EM observation confronted with increasing impact cultural noises, and the lack of a frequency range of higher than 1Hz observations. Control source of extremely low frequency (CSELF) EM is a kind of good prospective new approach. It not only has many advantages with high S/N ratio, large coverage area, probing depth ect., thereby facilitating the identification and capture anomaly signal, and it also can be used to study the electromagnetic field variation and to study the crustal medium changes of the electric structure.The first CSELF EM network for earthquake precursory monitoring with 30 observatories in China has been constructed. The observatories distribute in Beijing surrounding area and in the southern part of North-South Seismic Zone. GMS-07 system made by Metronix is equipped at each station. The observation mixed CSELF and nature source, that is, if during the control source is off transmitted, the nature source EM signal will be recorded. In genernal, there are 3 5 frequencies signals in the 0.1-300Hz frequency band will be transmit in every morning and evening in a fixed time (length 2 hours). Besides time, natural field to extend the frequency band (0.001 1000 Hz) will be observed by using 3 sample frequencies, 4096Hz sampling rate for HF, 256Hz for MF and 16Hz for LF. The low frequency band records continuously all-day and the high and medium frequency band use a slices record, the data records by cycling acquisition in every 10 minutes with length of about 4 to 8 seconds and 64 to 128 seconds , respectively. All the data is automatically processed by server installed in the observatory. The EDI file including EM field spectrums and MT responses and time series files will be sent the data center by internet. There shows observation data since the network set up. We get some EM field spectrum variations and the apparent resistivity changes of different frequencies with time on observatories. They show some regular and irregular changes. This study is supported by The ELF Engineering Project of China (15212Z0000001), National Natural Science Foundation of China (41674081) etc.
Select injury-related variables are affected by stride length and foot strike style during running.
Boyer, Elizabeth R; Derrick, Timothy R
2015-09-01
Some frontal plane and transverse plane variables have been associated with running injury, but it is not known if they differ with foot strike style or as stride length is shortened. To identify if step width, iliotibial band strain and strain rate, positive and negative free moment, pelvic drop, hip adduction, knee internal rotation, and rearfoot eversion differ between habitual rearfoot and habitual mid-/forefoot strikers when running with both a rearfoot strike (RFS) and a mid-/forefoot strike (FFS) at 3 stride lengths. Controlled laboratory study. A total of 42 healthy runners (21 habitual rearfoot, 21 habitual mid-/forefoot) ran overground at 3.35 m/s with both a RFS and a FFS at their preferred stride lengths and 5% and 10% shorter. Variables did not differ between habitual groups. Step width was 1.5 cm narrower for FFS, widening to 0.8 cm as stride length shortened. Iliotibial band strain and strain rate did not differ between foot strikes but decreased as stride length shortened (0.3% and 1.8%/s, respectively). Pelvic drop was reduced 0.7° for FFS compared with RFS, and both pelvic drop and hip adduction decreased as stride length shortened (0.8° and 1.5°, respectively). Peak knee internal rotation was not affected by foot strike or stride length. Peak rearfoot eversion was not different between foot strikes but decreased 0.6° as stride length shortened. Peak positive free moment (normalized to body weight [BW] and height [h]) was not affected by foot strike or stride length. Peak negative free moment was -0.0038 BW·m/h greater for FFS and decreased -0.0004 BW·m/h as stride length shortened. The small decreases in most variables as stride length shortened were likely associated with the concomitant wider step width. RFS had slightly greater pelvic drop, while FFS had slightly narrower step width and greater negative free moment. Shortening one's stride length may decrease or at least not increase propensity for running injuries based on the variables that we measured. One foot strike style does not appear universally better than the other; rather, different foot strike styles may predispose runners to different types of injuries. © 2015 The Author(s).
A New Family of Solvable Pearson-Dirichlet Random Walks
NASA Astrophysics Data System (ADS)
Le Caër, Gérard
2011-07-01
An n-step Pearson-Gamma random walk in ℝ d starts at the origin and consists of n independent steps with gamma distributed lengths and uniform orientations. The gamma distribution of each step length has a shape parameter q>0. Constrained random walks of n steps in ℝ d are obtained from the latter walks by imposing that the sum of the step lengths is equal to a fixed value. Simple closed-form expressions were obtained in particular for the distribution of the endpoint of such constrained walks for any d≥ d 0 and any n≥2 when q is either q = d/2 - 1 ( d 0=3) or q= d-1 ( d 0=2) (Le Caër in J. Stat. Phys. 140:728-751, 2010). When the total walk length is chosen, without loss of generality, to be equal to 1, then the constrained step lengths have a Dirichlet distribution whose parameters are all equal to q and the associated walk is thus named a Pearson-Dirichlet random walk. The density of the endpoint position of a n-step planar walk of this type ( n≥2), with q= d=2, was shown recently to be a weighted mixture of 1+ floor( n/2) endpoint densities of planar Pearson-Dirichlet walks with q=1 (Beghin and Orsingher in Stochastics 82:201-229, 2010). The previous result is generalized to any walk space dimension and any number of steps n≥2 when the parameter of the Pearson-Dirichlet random walk is q= d>1. We rely on the connection between an unconstrained random walk and a constrained one, which have both the same n and the same q= d, to obtain a closed-form expression of the endpoint density. The latter is a weighted mixture of 1+ floor( n/2) densities with simple forms, equivalently expressed as a product of a power and a Gauss hypergeometric function. The weights are products of factors which depends both on d and n and Bessel numbers independent of d.
Venter, Jan A; Prins, Herbert H T; Mashanova, Alla; Slotow, Rob
2017-01-01
Finding suitable forage patches in a heterogeneous landscape, where patches change dynamically both spatially and temporally could be challenging to large herbivores, especially if they have no a priori knowledge of the location of the patches. We tested whether three large grazing herbivores with a variety of different traits improve their efficiency when foraging at a heterogeneous habitat patch scale by using visual cues to gain a priori knowledge about potential higher value foraging patches. For each species (zebra ( Equus burchelli ), red hartebeest ( Alcelaphus buselaphus subspecies camaa ) and eland ( Tragelaphus oryx )), we used step lengths and directionality of movement to infer whether they were using visual cues to find suitable forage patches at a habitat patch scale. Step lengths were significantly longer for all species when moving to non-visible patches than to visible patches, but all movements showed little directionality. Of the three species, zebra movements were the most directional. Red hartebeest had the shortest step lengths and zebra the longest. We conclude that these large grazing herbivores may not exclusively use visual cues when foraging at a habitat patch scale, but would rather adapt their movement behaviour, mainly step length, to the heterogeneity of the specific landscape.
Smith, Cory M; Housh, Terry J; Hill, Ethan C; Keller, Josh L; Johnson, Glen O; Schmidt, Richard J
2018-06-01
The purposes of this study were to examine: 1) the potential muscle-specific differences in voluntary electromechanical delay (EMD) and relaxation electromechanical delay (R-EMD), and 2) the effects of intensity on EMD and R-EMD during step incremental isometric muscle actions from 10 to 100% maximal voluntary isometric contraction (MVIC). EMD and R-EMD measures were calculated from the simultaneous assessments of electromyography, mechanomyography, and force production from the vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) during step isometric muscle actions. There were no differences between the VL, VM, and RF for the voluntary EMD E-M (onsets of the electromyographic to mechanomyographic signals), EMD M-F (onsets the mechanomyographic to force production), or EMD E-F (onsets of the electromyographic signal to force production) as well as R-EMD E-M (cessation of electromyographic to mechanomyographic signal), R-EMD M-F (cessation of mechanomyographic signal to force cessation), or R-EMD E-F (cessation of electromyorgraphic signal to force cessation) at any intensity. There were decreases in all EMD and R-EMD measures with increases in intensity. The relative contributions from EMD E-M and EMD M-F to EMD E-F as well as R-EMD E-M and R-EMD M-F to R-EMD E-F remained similar across all intensities. The superficial muscles of the quadriceps femoris shared similar EMD and R-EMD measurements.
Sen. Bennet, Michael F. [D-CO
2014-05-22
Senate - 05/22/2014 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Fransen, Erik; Perkisas, Stany; Verhoeven, Veronique; Beauchet, Olivier; Remmen, Roy
2017-01-01
Background Gait characteristics measured at usual pace may allow profiling in patients with cognitive problems. The influence of age, gender, leg length, modified speed or dual tasking is unclear. Methods Cross-sectional analysis was performed on a data registry containing demographic, physical and spatial-temporal gait parameters recorded in five walking conditions with a GAITRite® electronic carpet in community-dwelling older persons with memory complaints. Four cognitive stages were studied: cognitively healthy individuals, mild cognitive impaired patients, mild dementia patients and advanced dementia patients. Results The association between spatial-temporal gait characteristics and cognitive stages was the most prominent: in the entire study population using gait speed, steps per meter (translation for mean step length), swing time variability, normalised gait speed (corrected for leg length) and normalised steps per meter at all five walking conditions; in the 50-to-70 years old participants applying step width at fast pace and steps per meter at usual pace; in the 70-to-80 years old persons using gait speed and normalised gait speed at usual pace, fast pace, animal walk and counting walk or steps per meter and normalised steps per meter at all five walking conditions; in over-80 years old participants using gait speed, normalised gait speed, steps per meter and normalised steps per meter at fast pace and animal dual-task walking. Multivariable logistic regression analysis adjusted for gender predicted in two compiled models the presence of dementia or cognitive impairment with acceptable accuracy in persons with memory complaints. Conclusion Gait parameters in multiple walking conditions adjusted for age, gender and leg length showed a significant association with cognitive impairment. This study suggested that multifactorial gait analysis could be more informative than using gait analysis with only one test or one variable. Using this type of gait analysis in clinical practice could facilitate screening for cognitive impairment. PMID:28570662
Sensorimotor and Cognitive Predictors of Impaired Gait Adaptability in Older People.
Caetano, Maria Joana D; Menant, Jasmine C; Schoene, Daniel; Pelicioni, Paulo H S; Sturnieks, Daina L; Lord, Stephen R
2017-09-01
The ability to adapt gait when negotiating unexpected hazards is crucial to maintain stability and avoid falling. This study investigated whether impaired gait adaptability in a task including obstacle and stepping targets is associated with cognitive and sensorimotor capacities in older adults. Fifty healthy older adults (74±7 years) were instructed to either (a) avoid an obstacle at usual step distance or (b) step onto a target at either a short or long step distance projected on a walkway two heel strikes ahead and then continue walking. Participants also completed cognitive and sensorimotor function assessments. Stroop test and reaction time performance significantly discriminated between participants who did and did not make stepping errors, and poorer Trail-Making test performance predicted shorter penultimate step length in the obstacle avoidance condition. Slower reaction time predicted poorer stepping accuracy; increased postural sway, weaker quadriceps strength, and poorer Stroop and Trail-Making test performances predicted increased number of steps taken to approach the target/obstacle and shorter step length; and increased postural sway and higher concern about falling predicted slower step velocity. Superior executive function, fast processing speed, and good muscle strength and balance were all associated with successful gait adaptability. Processing speed appears particularly important for precise foot placements; cognitive capacity for step length adjustments; and early and/or additional cognitive processing involving the inhibition of a stepping pattern for obstacle avoidance. This information may facilitate fall risk assessments and fall prevention strategies. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Who killed Rambhor?: The state of emergency medical services in India
Garg, Rajesh H
2012-01-01
In India, the healthcare delivery system starts up from the sub-center at the village level and reaches up to super specialty medical centers providing state of the art emergency medical services (EMS). These highest centers, located in big cities, are considered the last referral points for the patients from nearby cities and states. As the incidents of rail and road accidents have increased in recent years, the role of EMS becomes critical in saving precious lives. But when the facilities and management of these emergency centers succumbs before the patient, then the question arises regarding the adequate availability and quality of EMS. The death of an unknown common man, Rambhor, for want of EMS in three big hospitals in the national capital of India put a big question on the “health” of the emergency health services in India. The emergency services infrastructure seems inadequate and quality and timely provision of EMS to critical patients appears unsatisfactory. There is lack of emergency medicine (EM) specialists in India and also the postgraduation courses in EM have not gained foot in our medical education system. Creation of a Centralized Medical Emergency Body, implementation of management techniques, modification of medical curriculum, and fixing accountability are some of the few steps which are required to improve the EMS in India. PMID:22416155
Estimated Financing Amount Needed for Essential Medicines in China, 2014.
Xu, Wei; Xu, Zheng-Yuan; Cai, Gong-Jie; Kuo, Chiao-Yun; Li, Jing; Huang, Yi-Syuan
2016-03-20
At the present time, the government is considering to establish the independent financing system for essential medicines (EMs). However, it is still in the exploration phase. The objectives of this study were to calculate and estimate financing amount of EMs in China in 2014 and to provide data evidence for establishing financing mechanism of EMs. Two approaches were adopted in this study. First, we used a retrospective research to estimate the cost of EMs in China in 2014. We identified all the 520 drugs listed in the latest national EMs list (2012) and calculated the total sales amount of these drugs in 2014. The other approach included the steps that first selecting the 109 most common diseases in China, then identifying the EMs used to treat them, and finally estimating the total cost of these drugs. The results of the two methods, which showed the estimated financing amounts of EMs in China in 2014, were 17,776.44 million USD and 19,094.09 million USD, respectively. Comparing these two results, we concluded that the annual budget needed to provide for the EMs in China would be about 20 billion USD. Our study also indicated that the irrational drug use continued to plague the health system with intravenous fluids and antibiotics being the typical examples, as observed in other studies.
A theory of growing crystalline nanorods - Mode I
NASA Astrophysics Data System (ADS)
Du, Feng; Huang, Hanchen
2018-08-01
Nanorods grow in two possible modes during physical vapor deposition (PVD). In mode I, monolayer surface steps dictate the diameter of nanorods. In mode II, multiple-layer surface steps dictate the diameter, which is the smallest possible under physical vapor deposition [5,10]. This paper reports closed-form theories of terrace lengths and nanorod diameter during the growth in mode I, as a function of deposition conditions. The accompanying lattice kinetic Monte Carlo simulations verify these theories. This study reveals that (1) quasi-steady growth exists for each set of nanorod growth conditions, and (2) the characteristic length scales, including terrace lengths and nanorod diameter at the quasi-steady state, depend on the deposition conditions - deposition rate F, substrate temperature T, and incidence angle θ - only as a function of l2D/tan θ, with l2 D = 2(v2 D/Fcosθ) 1/3 as a diffusion-limited length scale and v2D as the atomic diffusion jump rate over monolayer surface steps.
Emotional influences on locomotor behavior.
Naugle, Kelly M; Joyner, Jessica; Hass, Chris J; Janelle, Christopher M
2010-12-01
Emotional responses to appetitive and aversive stimuli motivate approach and avoidance behaviors essential for survival. The purpose of the current study was to determine the impact of specific emotional stimuli on forward, approach-oriented locomotion. Steady state walking was assessed while participants walked toward pictures varying in emotional content (erotic, happy people, attack, mutilation, contamination, and neutral). Step length and step velocity were calculated for the first two steps following picture onset. Exposure to the mutilation and contamination pictures shortened the lengths of step one and step two compared to the erotic pictures. Additionally, step velocity was greater during exposure to the erotic pictures compared to (1) the contamination and mutilation pictures for step one and (2) all other picture categories for step two. These findings suggest that locomotion is facilitated when walking toward approach-oriented emotional stimuli but compromised when walking toward aversive emotional stimuli. The data extend our understanding of fundamental interactions among motivational orientations, emotional reactions, and resultant actions. Theoretical and practical implications are discussed. Copyright © 2010 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
von Davier, Matthias
2016-01-01
This report presents results on a parallel implementation of the expectation-maximization (EM) algorithm for multidimensional latent variable models. The developments presented here are based on code that parallelizes both the E step and the M step of the parallel-E parallel-M algorithm. Examples presented in this report include item response…
High S/N Ratio Slotted Step Piezoresistive Microcantilever Designs for Biosensors
Ansari, Mohd Zahid; Cho, Chongdu
2013-01-01
This study proposes new microcantilever designs in slotted step configuration to improve the S/N ratio of surface stress-based sensors used in physical, chemical, biochemical and biosensor applications. The cantilevers are made of silicon dioxide with a u-shaped silicon piezoresistor in p-doped. The cantilever step length and piezoresistor length is varied along with the operating voltage to characterise the surface stress sensitivity and thermal drifting sensitivity of the cantilevers when used as immunosensor. The numerical analysis is performed using ANSYS Multiphysics. Results show the surface stress sensitivity and the S/N ratio of the slotted step cantilevers is improved by more than 32% and 22%, respectively, over its monolithic counterparts. PMID:23535637
High S/N ratio slotted step piezoresistive microcantilever designs for biosensors.
Ansari, Mohd Zahid; Cho, Chongdu
2013-03-26
This study proposes new microcantilever designs in slotted step configuration to improve the S/N ratio of surface stress-based sensors used in physical, chemical, biochemical and biosensor applications. The cantilevers are made of silicon dioxide with a u-shaped silicon piezoresistor in p-doped. The cantilever step length and piezoresistor length is varied along with the operating voltage to characterise the surface stress sensitivity and thermal drifting sensitivity of the cantilevers when used as immunosensor. The numerical analysis is performed using ANSYS Multiphysics. Results show the surface stress sensitivity and the S/N ratio of the slotted step cantilevers is improved by more than 32% and 22%, respectively, over its monolithic counterparts.
Multi-Step Time Series Forecasting with an Ensemble of Varied Length Mixture Models.
Ouyang, Yicun; Yin, Hujun
2018-05-01
Many real-world problems require modeling and forecasting of time series, such as weather temperature, electricity demand, stock prices and foreign exchange (FX) rates. Often, the tasks involve predicting over a long-term period, e.g. several weeks or months. Most existing time series models are inheritably for one-step prediction, that is, predicting one time point ahead. Multi-step or long-term prediction is difficult and challenging due to the lack of information and uncertainty or error accumulation. The main existing approaches, iterative and independent, either use one-step model recursively or treat the multi-step task as an independent model. They generally perform poorly in practical applications. In this paper, as an extension of the self-organizing mixture autoregressive (AR) model, the varied length mixture (VLM) models are proposed to model and forecast time series over multi-steps. The key idea is to preserve the dependencies between the time points within the prediction horizon. Training data are segmented to various lengths corresponding to various forecasting horizons, and the VLM models are trained in a self-organizing fashion on these segments to capture these dependencies in its component AR models of various predicting horizons. The VLM models form a probabilistic mixture of these varied length models. A combination of short and long VLM models and an ensemble of them are proposed to further enhance the prediction performance. The effectiveness of the proposed methods and their marked improvements over the existing methods are demonstrated through a number of experiments on synthetic data, real-world FX rates and weather temperatures.
Lerner, E Brooke; Garrison, Herbert G; Nichol, Graham; Maio, Ronald F; Lookman, Hunaid A; Sheahan, William D; Franz, Timothy R; Austad, James D; Ginster, Aaron M; Spaite, Daniel W
2012-02-01
Calculating the cost of an emergency medical services (EMS) system using a standardized method is important for determining the value of EMS. This article describes the development of a methodology for calculating the cost of an EMS system to its community. This includes a tool for calculating the cost of EMS (the "cost workbook") and detailed directions for determining cost (the "cost guide"). The 12-step process that was developed is consistent with current theories of health economics, applicable to prehospital care, flexible enough to be used in varying sizes and types of EMS systems, and comprehensive enough to provide meaningful conclusions. It was developed by an expert panel (the EMS Cost Analysis Project [EMSCAP] investigator team) in an iterative process that included pilot testing the process in three diverse communities. The iterative process allowed ongoing modification of the toolkit during the development phase, based upon direct, practical, ongoing interaction with the EMS systems that were using the toolkit. The resulting methodology estimates EMS system costs within a user-defined community, allowing either the number of patients treated or the estimated number of lives saved by EMS to be assessed in light of the cost of those efforts. Much controversy exists about the cost of EMS and whether the resources spent for this purpose are justified. However, the existence of a validated toolkit that provides a standardized process will allow meaningful assessments and comparisons to be made and will supply objective information to inform EMS and community officials who are tasked with determining the utilization of scarce societal resources. © 2012 by the Society for Academic Emergency Medicine.
Electron Microscopy of Ebola Virus-Infected Cells.
Noda, Takeshi
2017-01-01
Ebola virus (EBOV) replicates in host cells, where both viral and cellular components show morphological changes during the process of viral replication from entry to budding. These steps in the replication cycle can be studied using electron microscopy (EM), including transmission electron microscopy (TEM) and scanning electron microscopy (SEM), which is one of the most useful methods for visualizing EBOV particles and EBOV-infected cells at the ultrastructural level. This chapter describes conventional methods for EM sample preparation of cultured cells infected with EBOV.
Verrel, Julius; Lövdén, Martin; Lindenberger, Ulman
2012-01-01
Stable walking depends on the coordination of multiple biomechanical degrees of freedom to ensure the dynamic maintenance of whole-body equilibrium as well as continuous forward progression. We investigated adult age-related differences in whole-body coordination underlying stabilization of center of mass (CoM) position and step pattern during locomotion. Sixteen younger (20-30 years) and 16 healthy older men (65-80 years) walked on a motorized treadmill at 80%, 100% and 120% of their self-selected preferred speed. Preferred speeds did not differ between the age groups. Motor-equivalent stabilization of step parameters (step length and width) and CoM position relative to the support (back and front foot) was examined using a generalized covariation analysis. Across age groups, covariation indices were highest for CoM position relative to the front foot, the measure most directly related to body equilibrium. Compared to younger adults, older adults showed lower covariation indices with respect to step length, extending previous findings of age-related differences in motor-equivalent coordination. In contrast, no reliable age differences were found regarding stabilization of step width or any of the CoM parameters. The observed pattern of results may reflect robust prioritization of balance over step pattern regularity, which may be adaptive in the face of age-associated sensorimotor losses and decline of coordinative capacities.
Kumar, Nitin; Conwell, Darwin L; Thompson, Christopher C
2014-11-01
Infected walled-off pancreatic necrosis (WOPN) is a complication of acute pancreatitis requiring intervention. Surgery is associated with considerable morbidity. Percutaneous catheter drainage (PCD), initial therapy in the step-up approach, minimizes complications. Direct endoscopic necrosectomy (DEN) has demonstrated safety and efficacy. We compared outcome and health care utilization of DEN versus step-up approach. This was a matched cohort study using a prospective registry. Twelve consecutive DEN patients were matched with 12 step-up approach patients. Outcomes were clinical resolution after primary therapeutic modality, new organ failure, mortality, endocrine or exocrine insufficiency, length of stay, and health care utilization. Clinical resolution in 11 of 12 patients after DEN versus 3 of 12 step-up approach patients after PCD (P < 0.01). Nine step-up approach patients required surgery; 7 of these experienced complications. Direct endoscopic necrosectomy resulted in less new antibiotic use, pulmonary failure, endocrine insufficiency, and shorter length of stay (P < 0.05). Health care utilization was lower after DEN by 5.2:1 (P < 0.01). Direct endoscopic necrosectomy may be superior to step-up approach for WOPN with suspected or established infection. Primary PCD generally delayed definitive therapy. Given the higher efficacy, shorter length of stay, and lower health care utilization, DEN could be the first-line therapy for WOPN, with primary PCD for inaccessible or immature collections.
Kim, Jeong-Soo; Kang, Sun-Young; Jeon, Hye-Seon
2015-01-01
The body-weight-support treadmill (BWST) is commonly used for gait rehabilitation, but other forms of BWST are in development, such as visual-deprivation BWST (VDBWST). In this study, we compare the effect of VDBWST training and conventional BWST training on spatiotemporal gait parameters for three individuals who had hemiparetic strokes. We used a single-subject experimental design, alternating multiple baselines across the individuals. We recruited three individuals with hemiparesis from stroke; two on the left side and one on the right. For the main outcome measures we assessed spatiotemporal gait parameters using GAITRite, including: gait velocity; cadence; step time of the affected side (STA); step time of the non-affected side (STN); step length of the affected side (SLA); step length of the non-affected side (SLN); step-time asymmetry (ST-asymmetry); and step-length asymmetry (SL-asymmetry). Gait velocity, cadence, SLA, and SLN increased from baseline after both interventions, but STA, ST-asymmetry, and SL-asymmetry decreased from the baseline after the interventions. The VDBWST was significantly more effective than the BWST for increasing gait velocity and cadence and for decreasing ST-asymmetry. VDBWST is more effective than BWST for improving gait performance during the rehabilitation for ground walking.
Zijlstra, Agnes; Zijlstra, Wiebren
2013-09-01
Inverted pendulum (IP) models of human walking allow for wearable motion-sensor based estimations of spatio-temporal gait parameters during unconstrained walking in daily-life conditions. At present it is unclear to what extent different IP based estimations yield different results, and reliability and validity have not been investigated in older persons without a specific medical condition. The aim of this study was to compare reliability and validity of four different IP based estimations of mean step length in independent-living older persons. Participants were assessed twice and walked at different speeds while wearing a tri-axial accelerometer at the lower back. For all step-length estimators, test-retest intra-class correlations approached or were above 0.90. Intra-class correlations with reference step length were above 0.92 with a mean error of 0.0 cm when (1) multiplying the estimated center-of-mass displacement during a step by an individual correction factor in a simple IP model, or (2) adding an individual constant for bipedal stance displacement to the estimated displacement during single stance in a 2-phase IP model. When applying generic corrections or constants in all subjects (i.e. multiplication by 1.25, or adding 75% of foot length), correlations were above 0.75 with a mean error of respectively 2.0 and 1.2 cm. Although the results indicate that an individual adjustment of the IP models provides better estimations of mean step length, the ease of a generic adjustment can be favored when merely evaluating intra-individual differences. Further studies should determine the validity of these IP based estimations for assessing gait in daily life. Copyright © 2013 Elsevier B.V. All rights reserved.
Approach to inguinal hernia in high-risk geriatric patients: Should it be elective or emergent?
Işıl, Rıza Gürhan; Yazıcı, Pınar; Demir, Uygar; Kaya, Cemal; Bostancı, Özgür; İdiz, Ufuk Oğuz; Işıl, Canan Tülay; Demircioğlu, Mahmut Kaan; Mihmanlı, Mehmet
2017-03-01
Elderly patients are more prone to have inguinal hernia due to weakened abdominal musculature. However, surgical repair of inguinal hernia (SRIH) may not be performed or may be delayed due to greater risk in presence of comorbidities. Present study is investigation of outcome of elective and emergency SRIH in geriatric patients. Records of total of 384 high-risk (American Society of Anesthesiology classification III-IV) patients aged >65 years who underwent SRIH between January 2010 and December 2014 were reviewed. Patients were divided into 2 groups according to procedure type: elective (Group EL) or emergency (Group EM). Demographic features and surgical and postoperative period data of 2 groups were recorded and compared. Demographic data were similar, but number of ASA IV patients was greater in Group EM. Frequency of intestinal resection was significantly greater in emergency surgery group (1% vs 21%; p<0.01). Length of hospital stay (1.3 days vs 7.9 days; p<0.01) and intensive care unit stay (0.17 days vs 4.04 days; p<0.01) were also greater in Group EM. Morbidity (1% vs 24%; p<0.01) and mortality (0.3% vs 11%; p<0.01) were also significantly higher in Group EM compared to elective SRIH group. Emergency inguinal hernia surgery is associated with significantly higher morbidity and mortality compared with elective SRIH in high-risk geriatric patients. Elective hernia repair in these patients should be considered to reduce risk of need for intestinal resection as well as length of hospital stay.
Merlin, Mark A; Wong, Matthew L; Pryor, Peter W; Rynn, Kevin; Marques-Baptista, Andreia; Perritt, Rachael; Stanescu, Catherine G; Fallon, Timothy
2009-01-01
The investigation seeks to determine the prevalence of methicillin-resistant Staphylococcus aureus (MRSA) on the stethoscopes of emergency medical services (EMS) providers. While stethoscopes are known fomites for MRSA, the prevalence of MRSA in the prehospital setting is not well documented in the literature. This was a prospective, observational cohort study of 50 stethoscopes provided by consecutive, consenting EMS providers at our academic emergency department (ED). Stethoscopes were swabbed with saline culture applicators and samples were cultured on a commercial MRSA test kit containing mannitol salt agar with oxacillin. After 72 hours of incubation at 37 degrees C, two emergency physicians and one microbiologist analyzed the plates independently. MRSA colonization was recorded as positive if all three reviewers agreed that colonization had occurred. Of 50 stethoscopes, 16 had MRSA colonization, and 16 (32%) EMS professionals had no recollection of when their stethoscopes had been cleaned last. Reported length of time since last cleaning was grouped into six categories: one to seven days, eight to 14 days, 15 to 30 days, 31 to 180 days, 181 days to 365 days, and unknown. The median time frame reported since the last cleaning was one to seven days. In the model, an increase from one time category to the next increased the odds of MRSA colonization by 1.86 (odds ratio = 1.86, p = 0.038). In this ED setting, MRSA was found on approximately one in three stethoscopes of EMS professionals. A longer length of time since the last stethoscope cleaning increased the odds of MRSA colonization.
Meteorology and the physical activity of the elderly: the Nakanojo Study
NASA Astrophysics Data System (ADS)
Togo, Fumiharu; Watanabe, Eiji; Park, Hyuntae; Shephard, Roy J.; Aoyagi, Yukitoshi
2005-11-01
Seasonal changes in ambient temperature and day length are thought to modify habitual physical activity. However, relationships between such environmental factors and the daily physical activity of older populations remain unclear. The present study thus examined associations between meteorological variables and the number of steps taken per day by elderly Japanese. Continuous pedometer counts over a 450-day period were collected from 41 healthy subjects (age 71±4 years), none of whom engaged in any specific occupational activity or exercise programs. An electronic physical activity monitor was attached to a belt worn on the left side of the body throughout the day. Daily values for mean ambient temperature, duration of bright sunshine, mean wind speed, mean relative humidity, and precipitation were obtained from local meteorological stations. The day length was calculated from times of sunrise and sunset. Based on the entire group of 41 subjects (ensemble average), a subject’s step count per day decreased exponentially with increasing precipitation (r2=0.19, P<0.05). On days when precipitation was <1 mm, the step count increased with the mean ambient temperature over the range of 2 to 17°C, but decreased over the range 17 29°C. The daily step count also tended to increase with day length, but the regression coefficient of determination attributable to step count and mean ambient temperature (r2=0.32, P<0.05) exceeded that linking the step count and day length (r2=0.13, P<0.05). The influence of other meteorological factors was small (r2≤0.03) and of little practical significance. On days when precipitation is <1 mm, physical activity is associated more strongly with ambient temperature than with day length, duration of bright sunshine, wind speed, or relative humidity. Our findings have practical implications for health promotion efforts designed to increase the physical activity of elderly people consistently in the face of seasonal variations in environmental conditions.
jInv: A Modular and Scalable Framework for Electromagnetic Inverse Problems
NASA Astrophysics Data System (ADS)
Belliveau, P. T.; Haber, E.
2016-12-01
Inversion is a key tool in the interpretation of geophysical electromagnetic (EM) data. Three-dimensional (3D) EM inversion is very computationally expensive and practical software for inverting large 3D EM surveys must be able to take advantage of high performance computing (HPC) resources. It has traditionally been difficult to achieve those goals in a high level dynamic programming environment that allows rapid development and testing of new algorithms, which is important in a research setting. With those goals in mind, we have developed jInv, a framework for PDE constrained parameter estimation problems. jInv provides optimization and regularization routines, a framework for user defined forward problems, and interfaces to several direct and iterative solvers for sparse linear systems. The forward modeling framework provides finite volume discretizations of differential operators on rectangular tensor product meshes and tetrahedral unstructured meshes that can be used to easily construct forward modeling and sensitivity routines for forward problems described by partial differential equations. jInv is written in the emerging programming language Julia. Julia is a dynamic language targeted at the computational science community with a focus on high performance and native support for parallel programming. We have developed frequency and time-domain EM forward modeling and sensitivity routines for jInv. We will illustrate its capabilities and performance with two synthetic time-domain EM inversion examples. First, in airborne surveys, which use many sources, we achieve distributed memory parallelism by decoupling the forward and inverse meshes and performing forward modeling for each source on small, locally refined meshes. Secondly, we invert grounded source time-domain data from a gradient array style induced polarization survey using a novel time-stepping technique that allows us to compute data from different time-steps in parallel. These examples both show that it is possible to invert large scale 3D time-domain EM datasets within a modular, extensible framework written in a high-level, easy to use programming language.
Bernhardt, Paul W.; Zhang, Daowen; Wang, Huixia Judy
2014-01-01
Joint modeling techniques have become a popular strategy for studying the association between a response and one or more longitudinal covariates. Motivated by the GenIMS study, where it is of interest to model the event of survival using censored longitudinal biomarkers, a joint model is proposed for describing the relationship between a binary outcome and multiple longitudinal covariates subject to detection limits. A fast, approximate EM algorithm is developed that reduces the dimension of integration in the E-step of the algorithm to one, regardless of the number of random effects in the joint model. Numerical studies demonstrate that the proposed approximate EM algorithm leads to satisfactory parameter and variance estimates in situations with and without censoring on the longitudinal covariates. The approximate EM algorithm is applied to analyze the GenIMS data set. PMID:25598564
Volunteer Firefighter and EMS Personnel Job Protection Act
Sen. Carper, Thomas R. [D-DE
2009-05-12
Senate - 05/12/2009 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Volunteer Firefighter and EMS Support Act of 2009
Sen. Sanders, Bernard [I-VT
2009-04-02
Senate - 04/02/2009 Read twice and referred to the Committee on Homeland Security and Governmental Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Asymmetry in Determinants of Running Speed During Curved Sprinting.
Ishimura, Kazuhiro; Sakurai, Shinji
2016-08-01
This study investigates the potential asymmetries between inside and outside legs in determinants of curved running speed. To test these asymmetries, a deterministic model of curved running speed was constructed based on components of step length and frequency, including the distances and times of different step phases, takeoff speed and angle, velocities in different directions, and relative height of the runner's center of gravity. Eighteen athletes sprinted 60 m on the curved path of a 400-m track; trials were recorded using a motion-capture system. The variables were calculated following the deterministic model. The average speeds were identical between the 2 sides; however, the step length and frequency were asymmetric. In straight sprinting, there is a trade-off relationship between the step length and frequency; however, such a trade-off relationship was not observed in each step of curved sprinting in this study. Asymmetric vertical velocity at takeoff resulted in an asymmetric flight distance and time. The runners changed the running direction significantly during the outside foot stance because of the asymmetric centripetal force. Moreover, the outside leg had a larger tangential force and shorter stance time. These asymmetries between legs indicated the outside leg plays an important role in curved sprinting.
Manikandan, A.; Biplab, Sarkar; David, Perianayagam A.; Holla, R.; Vivek, T. R.; Sujatha, N.
2011-01-01
For high dose rate (HDR) brachytherapy, independent treatment verification is needed to ensure that the treatment is performed as per prescription. This study demonstrates dosimetric quality assurance of the HDR brachytherapy using a commercially available two-dimensional ion chamber array called IMatriXX, which has a detector separation of 0.7619 cm. The reference isodose length, step size, and source dwell positional accuracy were verified. A total of 24 dwell positions, which were verified for positional accuracy gave a total error (systematic and random) of –0.45 mm, with a standard deviation of 1.01 mm and maximum error of 1.8 mm. Using a step size of 5 mm, reference isodose length (the length of 100% isodose line) was verified for single and multiple catheters of same and different source loadings. An error ≤1 mm was measured in 57% of tests analyzed. Step size verification for 2, 3, 4, and 5 cm was performed and 70% of the step size errors were below 1 mm, with maximum of 1.2 mm. The step size ≤1 cm could not be verified by the IMatriXX as it could not resolve the peaks in dose profile. PMID:21897562
Sanchez, Jason C; Toal, Sarah J; Wang, Zheng; Dugan, Regina E; Trogler, William C
2007-11-01
Detection of trace quantities of explosive residues plays a key role in military, civilian, and counter-terrorism applications. To advance explosives sensor technology, current methods will need to become cheaper and portable while maintaining sensitivity and selectivity. The detection of common explosives including trinitrotoluene (TNT), cyclotrimethylenetrinitramine, cyclotetramethylene-tetranitramine, pentaerythritol tetranitrate, 2,4,6-trinitrophenyl-N-methylnitramine, and trinitroglycerin may be carried out using a three-step process combining "turn-off" and "turn-on" fluorimetric sensing. This process first detects nitroaromatic explosives by their quenching of green luminescence of polymetalloles (lambda em approximately 400-510 nm). The second step places down a thin film of 2,3-diaminonaphthalene (DAN) while "erasing" the polymetallole luminescence. The final step completes the reaction of the nitramines and/or nitrate esters with DAN resulting in the formation of a blue luminescent traizole complex (lambda(em) = 450 nm) providing a "turn-on" response for nitramine and nitrate ester-based explosives. Detection limits as low as 2 ng are observed. Solid-state detection of production line explosives demonstrates the applicability of this method to real world situations. This method offers a sensitive and selective detection process for a diverse group of the most common high explosives used in military and terrorist applications today.
Chen, Shicheng; Soehnlen, Marty; Downes, Frances P; Walker, Edward D
2017-01-01
Elizabethkingia meningoseptica is an emerging, healthcare-associated pathogen causing a high mortality rate in immunocompromised patients. We report the draft genome sequence of E. meningoseptica Em3, isolated from sputum from a patient with multiple underlying diseases. The genome has a length of 4,037,922 bp, a GC-content 36.4%, and 3673 predicted protein-coding sequences. Average nucleotide identity analysis (>95%) assigned the bacterium to the species E. meningoseptica. Genome analysis showed presence of the curli formation and assembly operon and a gene encoding hemagglutinins, indicating ability to form biofilm. In vitro biofilm assays demonstrated that E. meningoseptica Em3 formed more biofilm than E. anophelis Ag1 and E. miricola Emi3, both lacking the curli operon. A gene encoding thiol-activated cholesterol-dependent cytolysin in E. meningoseptica Em3 (potentially involved in lysing host immune cells) was also absent in E. anophelis Ag1 and E. miricola Emi3. Strain Em3 showed α-hemolysin activity on blood agar medium, congruent with presence of hemolysin and cytolysin genes. Furthermore, presence of heme uptake and utilization genes demonstrated adaptations for bloodstream infections. Strain Em3 contained 12 genes conferring resistance to β-lactams, including β-lactamases class A, class B, and metallo-β-lactamases. Results of comparative genomic analysis here provide insights into the evolution of E. meningoseptica Em3 as a pathogen.
NASA Astrophysics Data System (ADS)
Ma, Wei; Lu, Liang; Xu, Xianbo; Sun, Liepeng; Zhang, Zhouli; Dou, Weiping; Li, Chenxing; Shi, Longbo; He, Yuan; Zhao, Hongwei
2017-03-01
An 81.25 MHz continuous wave (CW) radio frequency quadrupole (RFQ) accelerator has been designed for the Low Energy Accelerator Facility (LEAF) at the Institute of Modern Physics (IMP) of the Chinese Academy of Science (CAS). In the CW operating mode, the proposed RFQ design adopted the conventional four-vane structure. The main design goals are providing high shunt impendence with low power losses. In the electromagnetic (EM) design, the π-mode stabilizing loops (PISLs) were optimized to produce a good mode separation. The tuners were also designed and optimized to tune the frequency and field flatness of the operating mode. The vane undercuts were optimized to provide a flat field along the RFQ cavity. Additionally, a full length model with modulations was set up for the final EM simulations. Following the EM design, thermal analysis of the structure was carried out. In this paper, detailed EM design and thermal simulations of the LEAF-RFQ will be presented and discussed. Structure error analysis was also studied.
Kuipers, Jeroen; van Ham, Tjakko J; Kalicharan, Ruby D; Veenstra-Algra, Anneke; Sjollema, Klaas A; Dijk, Freark; Schnell, Ulrike; Giepmans, Ben N G
2015-04-01
Ultrastructural examination of cells and tissues by electron microscopy (EM) yields detailed information on subcellular structures. However, EM is typically restricted to small fields of view at high magnification; this makes quantifying events in multiple large-area sample sections extremely difficult. Even when combining light microscopy (LM) with EM (correlated LM and EM: CLEM) to find areas of interest, the labeling of molecules is still a challenge. We present a new genetically encoded probe for CLEM, named "FLIPPER", which facilitates quantitative analysis of ultrastructural features in cells. FLIPPER consists of a fluorescent protein (cyan, green, orange, or red) for LM visualization, fused to a peroxidase allowing visualization of targets at the EM level. The use of FLIPPER is straightforward and because the module is completely genetically encoded, cells can be optimally prepared for EM examination. We use FLIPPER to quantify cellular morphology at the EM level in cells expressing a normal and disease-causing point-mutant cell-surface protein called EpCAM (epithelial cell adhesion molecule). The mutant protein is retained in the endoplasmic reticulum (ER) and could therefore alter ER function and morphology. To reveal possible ER alterations, cells were co-transfected with color-coded full-length or mutant EpCAM and a FLIPPER targeted to the ER. CLEM examination of the mixed cell population allowed color-based cell identification, followed by an unbiased quantitative analysis of the ER ultrastructure by EM. Thus, FLIPPER combines bright fluorescent proteins optimized for live imaging with high sensitivity for EM labeling, thereby representing a promising tool for CLEM.
Pylorus preserving loop duodeno-enterostomy with sleeve gastrectomy - preliminary results
2014-01-01
Background Bariatric operations mostly combine a restrictive gastric component with a rerouting of the intestinal passage. The pylorus can thereby be alternatively preserved or excluded. With the aim of performing a “pylorus-preserving gastric bypass”, we present early results of a proximal postpyloric loop duodeno-jejunostomy associated with a sleeve gastrectomy (LSG) compared to results of a parallel, but distal LSG with a loop duodeno-ileostomy as a two-step procedure. Methods 16 patients underwent either a two-step LSG with a distal loop duodeno-ileostomy (DIOS) as revisional bariatric surgery or a combined single step operation with a proximal duodeno-jejunostomy (DJOS). Total small intestinal length was determined to account for inter-individual differences. Results Mean operative time for the second-step of the DIOS operation was 121 min and 147 min for the combined DJOS operation. The overall intestinal length was 750.8 cm (range 600-900 cm) with a bypassed limb length of 235.7 cm in DJOS patients. The mean length of the common channel in DIOS patients measured 245.6 cm. Overall excess weight loss (%EWL) of the two-step DIOS procedure came to 38.31% and 49.60%, DJOS patients experienced an %EWL of 19.75% and 46.53% at 1 and 6 months, resp. No complication related to the duodeno-enterostomy occurred. Conclusions Loop duodeno-enterosomies with sleeve gastrectomy can be safely performed and may open new alternatives in bariatric surgery with the possibility for inter-individual adaptation. PMID:24725654
Visual control of foot placement when walking over complex terrain.
Matthis, Jonathan S; Fajen, Brett R
2014-02-01
The aim of this study was to investigate the role of visual information in the control of walking over complex terrain with irregularly spaced obstacles. We developed an experimental paradigm to measure how far along the future path people need to see in order to maintain forward progress and avoid stepping on obstacles. Participants walked over an array of randomly distributed virtual obstacles that were projected onto the floor by an LCD projector while their movements were tracked by a full-body motion capture system. Walking behavior in a full-vision control condition was compared with behavior in a number of other visibility conditions in which obstacles did not appear until they fell within a window of visibility centered on the moving observer. Collisions with obstacles were more frequent and, for some participants, walking speed was slower when the visibility window constrained vision to less than two step lengths ahead. When window sizes were greater than two step lengths, the frequency of collisions and walking speed were weakly affected or unaffected. We conclude that visual information from at least two step lengths ahead is needed to guide foot placement when walking over complex terrain. When placed in the context of recent research on the biomechanics of walking, the findings suggest that two step lengths of visual information may be needed because it allows walkers to exploit the passive mechanical forces inherent to bipedal locomotion, thereby avoiding obstacles while maximizing energetic efficiency. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Performance of a visuomotor walking task in an augmented reality training setting.
Haarman, Juliet A M; Choi, Julia T; Buurke, Jaap H; Rietman, Johan S; Reenalda, Jasper
2017-12-01
Visual cues can be used to train walking patterns. Here, we studied the performance and learning capacities of healthy subjects executing a high-precision visuomotor walking task, in an augmented reality training set-up. A beamer was used to project visual stepping targets on the walking surface of an instrumented treadmill. Two speeds were used to manipulate task difficulty. All participants (n = 20) had to change their step length to hit visual stepping targets with a specific part of their foot, while walking on a treadmill over seven consecutive training blocks, each block composed of 100 stepping targets. Distance between stepping targets was varied between short, medium and long steps. Training blocks could either be composed of random stepping targets (no fixed sequence was present in the distance between the stepping targets) or sequenced stepping targets (repeating fixed sequence was present). Random training blocks were used to measure non-specific learning and sequenced training blocks were used to measure sequence-specific learning. Primary outcome measures were performance (% of correct hits), and learning effects (increase in performance over the training blocks: both sequence-specific and non-specific). Secondary outcome measures were the performance and stepping-error in relation to the step length (distance between stepping target). Subjects were able to score 76% and 54% at first try for lower speed (2.3 km/h) and higher speed (3.3 km/h) trials, respectively. Performance scores did not increase over the course of the trials, nor did the subjects show the ability to learn a sequenced walking task. Subjects were better able to hit targets while increasing their step length, compared to shortening it. In conclusion, augmented reality training by use of the current set-up was intuitive for the user. Suboptimal feedback presentation might have limited the learning effects of the subjects. Copyright © 2017 Elsevier B.V. All rights reserved.
Aggarwal, Praveen; Galwankar, Sagar; Kalra, Om Prakash; Bhalla, Ashish; Bhoi, Sanjeev; Sundarakumar, Sundarajan
2014-01-01
Emergency medicine services and training in Emergency Medicine (EM) has developed to a large extent in developed countries but its establishment is far from optimal in developing countries. In India, Medical Council of India (MCI) has taken great steps by notifying EM as a separate specialty and so far 20 medical colleges have already initiated 3-year training program in EM. However, there has been shortage of trained faculty, and ambiguity regarding curriculum, rotation policy, infrastructure, teachers’ eligibility qualifications and scheme of examination. Academic College of Emergency Experts in India (ACEE-India) has been a powerful advocate for developing Academic EM in India. The ACEE's Education Development Committee (EDC) was created to chalk out guidelines for staffing, infrastructure, resources, curriculum, and training which may be of help to the MCI and the National Board of Examinations (NBE) to set standards for starting 3-year training program in EM and develop the departments of EM as centers of quality education, research, and treatment across India. This paper has made an attempt to give recommendations so as to provide a uniform framework to the institutions, thus guiding them towards establishing an academic Department of EM for starting the 3-year training program in the specialty of EM. PMID:25114431
Aggarwal, Praveen; Galwankar, Sagar; Kalra, Om Prakash; Bhalla, Ashish; Bhoi, Sanjeev; Sundarakumar, Sundarajan
2014-07-01
Emergency medicine services and training in Emergency Medicine (EM) has developed to a large extent in developed countries but its establishment is far from optimal in developing countries. In India, Medical Council of India (MCI) has taken great steps by notifying EM as a separate specialty and so far 20 medical colleges have already initiated 3-year training program in EM. However, there has been shortage of trained faculty, and ambiguity regarding curriculum, rotation policy, infrastructure, teachers' eligibility qualifications and scheme of examination. Academic College of Emergency Experts in India (ACEE-India) has been a powerful advocate for developing Academic EM in India. The ACEE's Education Development Committee (EDC) was created to chalk out guidelines for staffing, infrastructure, resources, curriculum, and training which may be of help to the MCI and the National Board of Examinations (NBE) to set standards for starting 3-year training program in EM and develop the departments of EM as centers of quality education, research, and treatment across India. This paper has made an attempt to give recommendations so as to provide a uniform framework to the institutions, thus guiding them towards establishing an academic Department of EM for starting the 3-year training program in the specialty of EM.
Accidents of Electrical and Mechanical Works for Public Sector Projects in Hong Kong
Wong, Francis K. W.; Chan, Albert P. C.; Wong, Andy K. D.; Choi, Tracy N. Y.
2018-01-01
A study on electrical and mechanical (E&M) works-related accidents for public sector projects provided the opportunity to gain a better understanding of the causes of accidents by analyzing the circumstances of all E&M works accidents. The research aims to examine accidents of E&M works which happened in public sector projects. A total of 421 E&M works-related accidents in the “Public Works Programme Construction Site Safety and Environmental Statistics” (PCSES) system were extracted for analysis. Two-step cluster analysis was conducted to classify the E&M accidents into different groups. The results identified three E&M accidents groups: (1) electricians with over 15 years of experience were prone to ‘fall of person from height’; (2) electricians with zero to five years of experience were prone to ‘slip, trip or fall on same level’; (3) air-conditioning workers with zero to five years of experience were prone to multiple types of accidents. Practical measures were recommended for each specific cluster group to avoid recurrence of similar accidents. The accident analysis would be vital for industry practitioners to enhance the safety performance of public sector projects. This study contributes to filling the knowledge gap of how and why E&M accidents occur and promulgating preventive measures for E&M accidents which have been under researched. PMID:29534429
Estimated Financing Amount Needed for Essential Medicines in China, 2014
Xu, Wei; Xu, Zheng-Yuan; Cai, Gong-Jie; Kuo, Chiao-Yun; Li, Jing; Huang, Yi-Syuan
2016-01-01
Background: At the present time, the government is considering to establish the independent financing system for essential medicines (EMs). However, it is still in the exploration phase. The objectives of this study were to calculate and estimate financing amount of EMs in China in 2014 and to provide data evidence for establishing financing mechanism of EMs. Methods: Two approaches were adopted in this study. First, we used a retrospective research to estimate the cost of EMs in China in 2014. We identified all the 520 drugs listed in the latest national EMs list (2012) and calculated the total sales amount of these drugs in 2014. The other approach included the steps that first selecting the 109 most common diseases in China, then identifying the EMs used to treat them, and finally estimating the total cost of these drugs. Results: The results of the two methods, which showed the estimated financing amounts of EMs in China in 2014, were 17,776.44 million USD and 19,094.09 million USD, respectively. Conclusions: Comparing these two results, we concluded that the annual budget needed to provide for the EMs in China would be about 20 billion USD. Our study also indicated that the irrational drug use continued to plague the health system with intravenous fluids and antibiotics being the typical examples, as observed in other studies. PMID:26960376
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiller, Steven R.; Schwartz, Lisa C.
Demand-side energy efficiency (efficiency) represents a low-cost opportunity to reduce electricity consumption and demand and provide a wide range of non-energy benefits, including avoiding air pollution. Efficiency-related energy and non-energy impacts are determined and documented by implementing evaluation, measurement and verification (EM&V) systems. This technical brief describes efficiency EM&V coordination strategies that Western states can consider taking on together, outlines EM&V-related products that might be appropriate for multistate coordination, and identifies some implications of coordination. Coordinating efficiency EM&V activities can save both time and costs for state agencies and stakeholders engaged in efficiency activities and can be particularly beneficial formore » multiple states served by the same utility. First, the brief summarizes basic information on efficiency, its myriad potential benefits and EM&V for assessing those benefits. Second, the brief introduces the concept of multistate EM&V coordination in the context of assessing such benefits, including achievement of state and federal goals to reduce air pollutants.1 Next, the brief presents three coordination strategy options for efficiency EM&V: information clearinghouse/exchange, EM&V product development, and a regional energy efficiency tracking system platform. The brief then describes five regional EM&V products that could be developed on a multistate basis: EM&V reporting formats, database of consistent deemed electricity savings values, glossary of definitions and concepts, efficiency EM&V methodologies, and EM&V professional standards or accreditation processes. Finally, the brief discusses options for next steps that Western states can take to consider multistate coordination on efficiency EM&V. Appendices provide background information on efficiency and EM&V, as well as definitions and suggested resources on the covered topics. This brief is intended to inform state public utility commissions, boards for public and consumer-owned utilities, state energy offices and air agencies, and other organizations involved in discussions about the use of efficiency EM&V.« less
NASA Astrophysics Data System (ADS)
Bayewu, Olateju O.; Oloruntola, Moroof O.; Mosuro, Ganiyu O.; Laniyan, Temitope A.; Ariyo, Stephen O.; Fatoba, Julius O.
2017-12-01
The geophysical assessment of groundwater in Awa-Ilaporu, near Ago Iwoye southwestern Nigeria was carried out with the aim of delineating probable areas of high groundwater potential. The area falls within the Crystalline Basement Complex of southwestern Nigeria which is predominantly underlain by banded gneiss, granite gneiss and pegmatite. The geophysical investigation involves the very low frequency electromagnetic (VLF-EM) and Vertical Electrical Sounding (VES) methods. The VLF-EM survey was at 10 m interval along eight traverses ranging between 290 and 700 m in length using ABEM WADI VLF-EM unit. The VLF-EM survey was used to delineate areas with conductive/fractured zones. Twenty-three VES surveys were carried out with the use of Campus Ohmega resistivity meter at different location and at locations areas delineated as high conductive areas by VLF-EM survey. The result of VLF-EM survey along its traverse was used in delineating high conductive/fractured zones, it is, however, in agreement with the delineation of the VES survey. The VES results showed 3-4 geoelectric layers inferred as sandy topsoil, sandy clay, clayey and fractured/fresh basement. The combination of these two methods, therefore, helped in resolving the prospecting location for the groundwater yield in the study area.
Validation of Foot Placement Locations from Ankle Data of a Kinect v2 Sensor
Geerse, Daphne; Coolen, Bert; Kolijn, Detmar; Roerdink, Melvyn
2017-01-01
The Kinect v2 sensor may be a cheap and easy to use sensor to quantify gait in clinical settings, especially when applied in set-ups integrating multiple Kinect sensors to increase the measurement volume. Reliable estimates of foot placement locations are required to quantify spatial gait parameters. This study aimed to systematically evaluate the effects of distance from the sensor, side and step length on estimates of foot placement locations based on Kinect’s ankle body points. Subjects (n = 12) performed stepping trials at imposed foot placement locations distanced 2 m or 3 m from the Kinect sensor (distance), for left and right foot placement locations (side), and for five imposed step lengths. Body points’ time series of the lower extremities were recorded with a Kinect v2 sensor, placed frontoparallelly on the left side, and a gold-standard motion-registration system. Foot placement locations, step lengths, and stepping accuracies were compared between systems using repeated-measures ANOVAs, agreement statistics and two one-sided t-tests to test equivalence. For the right side at the 2 m distance from the sensor we found significant between-systems differences in foot placement locations and step lengths, and evidence for nonequivalence. This distance by side effect was likely caused by differences in body orientation relative to the Kinect sensor. It can be reduced by using Kinect’s higher-dimensional depth data to estimate foot placement locations directly from the foot’s point cloud and/or by using smaller inter-sensor distances in the case of a multi-Kinect v2 set-up to estimate foot placement locations at greater distances from the sensor. PMID:28994731
Validation of Foot Placement Locations from Ankle Data of a Kinect v2 Sensor.
Geerse, Daphne; Coolen, Bert; Kolijn, Detmar; Roerdink, Melvyn
2017-10-10
The Kinect v2 sensor may be a cheap and easy to use sensor to quantify gait in clinical settings, especially when applied in set-ups integrating multiple Kinect sensors to increase the measurement volume. Reliable estimates of foot placement locations are required to quantify spatial gait parameters. This study aimed to systematically evaluate the effects of distance from the sensor, side and step length on estimates of foot placement locations based on Kinect's ankle body points. Subjects (n = 12) performed stepping trials at imposed foot placement locations distanced 2 m or 3 m from the Kinect sensor (distance), for left and right foot placement locations (side), and for five imposed step lengths. Body points' time series of the lower extremities were recorded with a Kinect v2 sensor, placed frontoparallelly on the left side, and a gold-standard motion-registration system. Foot placement locations, step lengths, and stepping accuracies were compared between systems using repeated-measures ANOVAs, agreement statistics and two one-sided t -tests to test equivalence. For the right side at the 2 m distance from the sensor we found significant between-systems differences in foot placement locations and step lengths, and evidence for nonequivalence. This distance by side effect was likely caused by differences in body orientation relative to the Kinect sensor. It can be reduced by using Kinect's higher-dimensional depth data to estimate foot placement locations directly from the foot's point cloud and/or by using smaller inter-sensor distances in the case of a multi-Kinect v2 set-up to estimate foot placement locations at greater distances from the sensor.
Guide to Developing an Environmental Management System - Act
This page takes you though the basic steps (Plan, Do, Check, Act) of building an Environmental Management System (EMS) as they are outlined in the 2001 Second Edition of Environmental Management Systems: An Implementation Guide. Act section.
Guide to Developing an Environmental Management System - Plan
This page takes you though the basic steps (Plan, Do, Check, Act) of building an Environmental Management System (EMS) as they are outlined in the 2001 Second Edition of Environmental Management Systems: An Implementation Guide. Plan section.
Guide to Developing an Environmental Management System - Check
This page takes you though the basic steps (Plan, Do, Check, Act) of building an Environmental Management System (EMS) as they are outlined in the 2001 Second Edition of Environmental Management Systems: An Implementation Guide. Check section.
High-resolution Single Particle Analysis from Electron Cryo-microscopy Images Using SPHIRE
Moriya, Toshio; Saur, Michael; Stabrin, Markus; Merino, Felipe; Voicu, Horatiu; Huang, Zhong; Penczek, Pawel A.; Raunser, Stefan; Gatsogiannis, Christos
2017-01-01
SPHIRE (SPARX for High-Resolution Electron Microscopy) is a novel open-source, user-friendly software suite for the semi-automated processing of single particle electron cryo-microscopy (cryo-EM) data. The protocol presented here describes in detail how to obtain a near-atomic resolution structure starting from cryo-EM micrograph movies by guiding users through all steps of the single particle structure determination pipeline. These steps are controlled from the new SPHIRE graphical user interface and require minimum user intervention. Using this protocol, a 3.5 Å structure of TcdA1, a Tc toxin complex from Photorhabdus luminescens, was derived from only 9500 single particles. This streamlined approach will help novice users without extensive processing experience and a priori structural information, to obtain noise-free and unbiased atomic models of their purified macromolecular complexes in their native state. PMID:28570515
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Hyun-Seob; Goldberg, Noam; Mahajan, Ashutosh
Elementary (flux) modes (EMs) have served as a valuable tool for investigating structural and functional properties of metabolic networks. Identification of the full set of EMs in genome-scale networks remains challenging due to combinatorial explosion of EMs in complex networks. It is often, however, that only a small subset of relevant EMs needs to be known, for which optimization-based sequential computation is a useful alternative. Most of the currently available methods along this line are based on the iterative use of mixed integer linear programming (MILP), the effectiveness of which significantly deteriorates as the number of iterations builds up. Tomore » alleviate the computational burden associated with the MILP implementation, we here present a novel optimization algorithm termed alternate integer linear programming (AILP). Results: Our algorithm was designed to iteratively solve a pair of integer programming (IP) and linear programming (LP) to compute EMs in a sequential manner. In each step, the IP identifies a minimal subset of reactions, the deletion of which disables all previously identified EMs. Thus, a subsequent LP solution subject to this reaction deletion constraint becomes a distinct EM. In cases where no feasible LP solution is available, IP-derived reaction deletion sets represent minimal cut sets (MCSs). Despite the additional computation of MCSs, AILP achieved significant time reduction in computing EMs by orders of magnitude. The proposed AILP algorithm not only offers a computational advantage in the EM analysis of genome-scale networks, but also improves the understanding of the linkage between EMs and MCSs.« less
EM Diffusion for a Time-Domain Airborne EM System
NASA Astrophysics Data System (ADS)
Yin, C.; Qiu, C.; Liu, Y.; Cai, J.
2014-12-01
Visualization of EM diffusion for an airborne EM (AEM) system is important for understanding the transient procedure of EM diffusion. The current distribution and diffusion features also provide effective means to evaluate EM footprint, depth of exploration and further help AEM system design and data interpretation. Most previous studies on EM diffusion (or "smoke ring" effect) are based on the static presentation of EM field, where the dynamic features of EM diffusion were not visible. For visualizing the dynamic feature of EM diffusion, we first calculate in this paper the frequency-domain EM field by downward continuation of the EM field at the EM receiver to the deep earth. After that, we transform the results to time-domain via a Fourier transform. We take a homogeneous half-space and a two-layered earth induced by a step pulse to calculate the EM fields and display the EM diffusion in the earth as 3D animated vectors or time-varying contours. The "smoke ring" effect of EM diffusion, dominated by the resistivity distribution of the earth, is clearly observed. The numerical results for an HCP (vertical magnetic dipole) and a VCX (horizontal magnetic dipole) transmitting coil above a homogeneous half-space of 100 ohm-m are shown in Fig.1. We display as example only the distribution of EM field inside the earth for the diffusion time of 0.05ms. The detailed EM diffusion will be shown in our future presentation. From the numerical experiments for different models, we find that 1) the current for either an HCP or a VCX transmitting dipole propagates downward and outward with time, becoming wider and more diffuse, forming a "smoke ring"; 2) for a VCX transmitter, the underground current forms two ellipses, corresponding to the two polarities of the magnetic flux of a horizontal magnetic dipole, injecting into or ejected from the earth; 3) for a HCP transmitter, however, the underground current forms only one circle, corresponding to the polarity of the magnetic flux for a vertical magnetic dipole, injecting into the earth; 4) there exists no vertical current in an isotropic homogeneous half-space. The currents for both HCP and VCX transmitting dipole flow horizontally.
Serrao, Mariano; Ranavolo, Alberto; Conte, Carmela; Davassi, Chiara; Mari, Silvia; Fasano, Alfonso; Chini, Giorgia; Coppola, Gianluca; Draicchio, Francesco; Pierelli, Francesco
2015-11-01
The aim of this study was to investigate the effect of a rotigotine transdermal patch on stationary and non-stationary locomotion in de novo Parkinson disease (PD) patients in an open-label uncontrolled study. A 3-D gait analysis system was used to investigate four different locomotor tasks: steady-state linear walking, gait initiation, gait termination and 180°-turning. A series of gait variables were measured for each locomotor task. PD patients who received rotigotine treatment (4-8 mg) displayed: (1) increased step length, gait speed, cadence and arm oscillations, and reduced double support duration and step asymmetry during steady-state linear gait; (2) increased initial step length during gait initiation; (3) increased final step length and gait speed, and decreased stability index during gait termination; (4) decreased duration of turning and head-pelvis delays during 180°-turning. The main finding that emerges from the present study is that the dopamine agonist rotigotine can improve various aspects of gait in de novo PD patients.
Petrie, David; Chopra, Anil; Chochinov, Alecs; Artz, Jennifer D; Schull, Michael; Tallon, John; Jones, Gordon; MacPhee, Shannon; Ackerman, Margaret; Stiell, Ian G; Christenson, Jim
2016-04-05
1) To identify the strengths and challenges of governance structures in academic emergency medicine (EM), and 2) to make recommendations on principles and approaches that may guide improvements. Over the course of 9 months, eight established EM leaders met by teleconference, reviewed the literature, and discussed their findings and experiences to arrive at recommendations on governance in academic units of EM. The results and recommendations were presented at the annual Canadian Association of Emergency Physicians (CAEP) Academic Symposium, where attendees provided feedback. The updated recommendations were subsequently distributed to the CAEP Academic Section for further input, and the final recommendations were decided by consensus. The panel identified four governance areas of interest: 1) the elements of governance; 2) the relationships between emergency physicians and academic units of EM, and between the academic units of EM and faculty of medicine; 3) current status of governance in Canadian academic units of EM; and 4) essential elements of good governance. Six recommendations were developed around three themes, including 1) the importance of good governance; 2) the purposes of an academic unit of EM; and 3) essential elements for better governance for academic units of EM. Recommendations included identifying the importance of good governance, recognizing the need to adapt to the different models depending on the local environment; seeking full departmental status, provided it is mutually beneficial to EM and the faculty of medicine (and health authority); using a consultation service to learn from the experience of other academic units of EM; and establishing an annual forum for EM leaders. Although governance of academic EM is complex, there are ways to iteratively improve the mission of academic units of EM: providing exceptional patient care through research and education. Although there is no one-size-fits-all guide, there are practical recommended steps for academic units of EM to consider.
Newgard, Craig D; Kampp, Michael; Nelson, Maria; Holmes, James F; Zive, Dana; Rea, Thomas; Bulger, Eileen M; Liao, Michael; Sherck, John; Hsia, Renee Y; Wang, N Ewen; Fleischman, Ross J; Barton, Erik D; Daya, Mohamud; Heineman, John; Kuppermann, Nathan
2012-05-01
"Emergency medical services (EMS) provider judgment" was recently added as a field triage criterion to the national guidelines, yet its predictive value and real world application remain unclear. We examine the use and independent predictive value of EMS provider judgment in identifying seriously injured persons. We analyzed a population-based retrospective cohort, supplemented by qualitative analysis, of injured children and adults evaluated and transported by 47 EMS agencies to 94 hospitals in five regions across the Western United States from 2006 to 2008. We used logistic regression models to evaluate the independent predictive value of EMS provider judgment for Injury Severity Score ≥ 16. EMS narratives were analyzed using qualitative methods to assess and compare common themes for each step in the triage algorithm, plus EMS provider judgment. 213,869 injured patients were evaluated and transported by EMS over the 3-year period, of whom 41,191 (19.3%) met at least one of the field triage criteria. EMS provider judgment was the most commonly used triage criterion (40.0% of all triage-positive patients; sole criterion in 21.4%). After accounting for other triage criteria and confounders, the adjusted odds ratio of Injury Severity Score ≥ 16 for EMS provider judgment was 1.23 (95% confidence interval, 1.03-1.47), although there was variability in predictive value across sites. Patients meeting EMS provider judgment had concerning clinical presentations qualitatively similar to those meeting mechanistic and other special considerations criteria. Among this multisite cohort of trauma patients, EMS provider judgment was the most commonly used field trauma triage criterion, independently associated with serious injury, and useful in identifying high-risk patients missed by other criteria. However, there was variability in predictive value between sites.
Emergency medicine in the developing world: a Delphi study.
Hodkinson, Peter W; Wallis, Lee A
2010-07-01
Emergency medicine (EM) as a specialty has developed rapidly in the western world, but remains largely immature in developing nations. There is an urgent need for emergency services, but no clear guidelines are available on the priorities for establishing EM in the developing world. This study seeks to establish consensus on key areas of EM development in developing world settings, with respect to scope of EM, staffing needs, training requirements, and research priorities. A three-round Delphi study was conducted via e-mail. A panel was convened of 50 EM specialists or equivalent, with experience in or interest in EM in the developing world. In the first round, panelists provided free-text statements on scope, staffing, training, and research priorities for EM in the developing world. A five-point Likert scale was used to rate agreement with the statements in Rounds 2 and 3. Consensus statements are presented as a series of synopsis statements for each of the four major themes. A total of 168 of 208 statements (81%) had reached consensus at the end of the study. Key areas in which consensus was reached included EM being a specialist-driven service, with substantial role for nonphysicians. International training courses should be adapted to local needs. EM research in developing countries should be clinically driven and focus on local issues of importance. The scope and function of EM and relationships with other specialties are defined. Unambiguous principles are laid out for the development of the specialty in developing world environments. The next step required in this process is translation into practical guidelines for the development of EM in developing world settings where they may be used to drive policy, protocols, and research. 2010 by the Society for Academic Emergency Medicine
Professional Staff in Canadian University Libraries.
ERIC Educational Resources Information Center
Rothstein, Samuel
1986-01-01
Data from three Canadian university libraries on length of service, degree of mobility, and age of professional staff suggest that the combination of middle age, long service, and immobility results in severe deficiencies of motivation, morale, and creativity. Job rotation and job enlargement are suggested as solutions. (EM)
Rainer, Georg; Kuhnert, Regina; Unterholzer, Mara; Dresch, Philipp; Gruber, Andreas; Peintner, Ursula
2015-01-01
Ectomycorrhizae (EM) are important for the survival of seedlings and trees, but how they will react to global warming or changes in soil fertility is still in question. We tested the effect of soil temperature manipulation and nitrogen fertilization on EM communities in a high-altitude Pinus cembra afforestation. The trees had been inoculated in the 1960s in a nursery with a mixture of Suillus placidus, S. plorans and S. sibircus. Sampling was performed during the third year of temperature manipulation in June and October 2013. Root tips were counted, sorted into morphotypes, and sequenced. Fungal biomass was measured as ergosterol and hyphal length. The EM potential of the soil was assessed with internal transcribed spacers (ITS) clone libraries from in-growth mesh bags (MB). Temperature manipulation of ± 1 °C had no effect on the EM community. A total of 33 operational taxonomic units (OTUs) were identified, 20 from the roots, 13 from MB. The inoculated Suillus spp. colonized 82% of the root tips, thus demonstrating that the inoculation was sustainable. Nitrogen fertilization had no impact on the EM community, but promoted depletion in soil organic matter, and caused a reduction in soil fungal biomass. PMID:29376899
Towards a Passive Low-Cost In-Home Gait Assessment System for Older Adults
Wang, Fang; Stone, Erik; Skubic, Marjorie; Keller, James M.; Abbott, Carmen; Rantz, Marilyn
2013-01-01
In this paper, we propose a webcam-based system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed, step time and step length from a three-dimensional voxel reconstruction, which is built from two calibrated webcam views. The gait parameters are validated with a GAITRite mat and a Vicon motion capture system in the lab with 13 participants and 44 tests, and again with GAITRite for 8 older adults in senior housing. An excellent agreement with intra-class correlation coefficients of 0.99 and repeatability coefficients between 0.7% and 6.6% was found for walking speed, step time and step length given the limitation of frame rate and voxel resolution. The system was further tested with 10 seniors in a scripted scenario representing everyday activities in an unstructured environment. The system results demonstrate the capability of being used as a daily gait assessment tool for fall risk assessment and other medical applications. Furthermore, we found that residents displayed different gait patterns during their clinical GAITRite tests compared to the realistic scenario, namely a mean increase of 21% in walking speed, a mean decrease of 12% in step time, and a mean increase of 6% in step length. These findings provide support for continuous gait assessment in the home for capturing habitual gait. PMID:24235111
The Influence of Added Mass on Optimal Step Length in Running.
Reenalda, Jasper; Maas, Maurice T F; de Koning, Jos J
2016-10-01
To examine the influence of induced changes in the morphology of the leg by adding mass on the optimal step length (OSL) in experienced runners to get more insight into parameters that influence preferred step length (PSL) and OSL. Thirteen experienced male runners (mean age 26.9 ± 6.1 y, height 183.7 ± 7.1 cm, mass 71.8 ± 5.9 kg) ran on a treadmill in 3 different conditions: unloaded (UL), loaded with 2 kg mass at the ankles (MA), and loaded with 2 kg mass at the hips (MH) at 7 different step lengths (SLs). SL deviations were expressed as deviations in relative leg length (%LL) from the individual PSL: 0%LL, ±5%LL, ±10%LL, and ±15%LL. Trials lasted 8 min, and 8 min of rest was given between trials. Oxygen uptake (V̇O 2 ) was expressed as a fraction of V̇O 2 at PSL + 0%LL in the unloaded condition (%V̇O 2 ). The %SL with the lowest value of %V̇O 2 was considered the OSL for this group of participants. OSL at the UL condition was 6% shorter than PSL. The MA condition resulted in a 7%LL larger OSL than at UL and MH (P < .05). The mass distribution of the leg is a determinant of the OSL. As a consequence of the added mass to the ankles, OSL was 7%LL longer. Morphological characteristics of the leg might therefore play an important role in determining the runner's individual optimal SL.
Stepped chute training wall height requirements
USDA-ARS?s Scientific Manuscript database
Stepped chutes are commonly used for overtopping protection for embankment dams. Aerated flow is commonly associated with stepped chutes if the chute has sufficient length. The aeration and turbulence of the flow can create a significant amount of splash over the training wall if not appropriately...
NASA Astrophysics Data System (ADS)
Ishibashi, Takuya; Watanabe, Noriaki; Hirano, Nobuo; Okamoto, Atsushi; Tsuchiya, Noriyoshi
2015-01-01
The present study evaluates aperture distributions and fluid flow characteristics for variously sized laboratory-scale granite fractures under confining stress. As a significant result of the laboratory investigation, the contact area in fracture plane was found to be virtually independent of scale. By combining this characteristic with the self-affine fractal nature of fracture surfaces, a novel method for predicting fracture aperture distributions beyond laboratory scale is developed. Validity of this method is revealed through reproduction of the results of laboratory investigation and the maximum aperture-fracture length relations, which are reported in the literature, for natural fractures. The present study finally predicts conceivable scale dependencies of fluid flows through joints (fractures without shear displacement) and faults (fractures with shear displacement). Both joint and fault aperture distributions are characterized by a scale-independent contact area, a scale-dependent geometric mean, and a scale-independent geometric standard deviation of aperture. The contact areas for joints and faults are approximately 60% and 40%. Changes in the geometric means of joint and fault apertures (µm), em, joint and em, fault, with fracture length (m), l, are approximated by em, joint = 1 × 102 l0.1 and em, fault = 1 × 103 l0.7, whereas the geometric standard deviations of both joint and fault apertures are approximately 3. Fluid flows through both joints and faults are characterized by formations of preferential flow paths (i.e., channeling flows) with scale-independent flow areas of approximately 10%, whereas the joint and fault permeabilities (m2), kjoint and kfault, are scale dependent and are approximated as kjoint = 1 × 10-12 l0.2 and kfault = 1 × 10-8 l1.1.
Effect of walking speed on lower extremity joint loading in graded ramp walking.
Schwameder, Hermann; Lindenhofer, Elke; Müller, Erich
2005-07-01
Lower extremity joint loading during walking is strongly affected by the steepness of the slope and might cause pain and injuries in lower extremity joint structures. One feasible measure to reduce joint loading is the reduction of walking speed. Positive effects have been shown for level walking, but not for graded walking or hiking conditions. The aim of the study was to quantify the effect of walking speed (separated into the two components, step length and cadence) on the joint power of the hip, knee and ankle and to determine the knee joint forces in uphill and downhill walking. Ten participants walked up and down a ramp with step lengths of 0.46, 0.575 and 0.69 m and cadences of 80, 100 and 120 steps per minute. The ramp was equipped with a force platform and the locomotion was filmed with a 60 Hz video camera. Loading of the lower extremity joints was determined using inverse dynamics. A two-dimensional knee model was used to calculate forces in the knee structures during the stance phase. Walking speed affected lower extremity joint loading substantially and significantly. Change of step length caused much greater loading changes for all joints compared with change of cadence; the effects were more distinct in downhill than in uphill walking. The results indicate that lower extremity joint loading can be effectively controlled by varying step length and cadence during graded uphill and downhill walking. Hikers can avoid or reduce pain and injuries by reducing walking speed, particularly in downhill walking.
Menz, Hylton B; Lord, Stephen R; Fitzpatrick, Richard C
2007-02-01
Many falls in older people occur while walking, however the mechanisms responsible for gait instability are poorly understood. Therefore, the aim of this study was to develop a plausible model describing the relationships between impaired sensorimotor function, fear of falling and gait patterns in older people. Temporo-spatial gait parameters and acceleration patterns of the head and pelvis were obtained from 100 community-dwelling older people aged between 75 and 93 years while walking on an irregular walkway. A theoretical model was developed to explain the relationships between these variables, assuming that head stability is a primary output of the postural control system when walking. This model was then tested using structural equation modeling, a statistical technique which enables the testing of a set of regression equations simultaneously. The structural equation model indicated that: (i) reduced step length has a significant direct and indirect association with reduced head stability; (ii) impaired sensorimotor function is significantly associated with reduced head stability, but this effect is largely indirect, mediated by reduced step length, and; (iii) fear of falling is significantly associated with reduced step length, but has little direct influence on head stability. These findings provide useful insights into the possible mechanisms underlying gait characteristics and risk of falling in older people. Particularly important is the indication that fear-related step length shortening may be maladaptive.
Mutoh, Tomoko; Mutoh, Tatsushi; Takada, Makoto; Doumura, Misato; Ihara, Masayo; Taki, Yasuyuki; Tsubone, Hirokazu; Ihara, Masahiro
2016-01-01
[Purpose] This case series aims to evaluate the effects of hippotherapy on gait and balance ability of children and adolescents with cerebral palsy using quantitative parameters for physical activity. [Subjects and Methods] Three patients with gait disability as a sequela of cerebral palsy (one female and two males; age 5, 12, and 25 years old) were recruited. Participants received hippotherapy for 30 min once a week for 2 years. Gait parameters (step rate, step length, gait speed, mean acceleration, and horizontal/vertical displacement ratio) were measured using a portable motion recorder equipped with a tri-axial accelerometer attached to the waist before and after a 10-m walking test. [Results] There was a significant increase in step length between before and after a single hippotherapy session. Over the course of 2 year intervention, there was a significant increase in step rate, gait speed, step length, and mean acceleration and a significant improvement in horizontal/vertical displacement ratio. [Conclusion] The data suggest that quantitative parameters derived from a portable motion recorder can track both immediate and long-term changes in the walking ability of children and adolescents with cerebral palsy undergoing hippotherapy. PMID:27821971
Comparison of step-by-step kinematics of resisted, assisted and unloaded 20-m sprint runs.
van den Tillaar, Roland; Gamble, Paul
2018-03-26
This investigation examined step-by-step kinematics of sprint running acceleration. Using a randomised counterbalanced approach, 37 female team handball players (age 17.8 ± 1.6 years, body mass 69.6 ± 9.1 kg, height 1.74 ± 0.06 m) performed resisted, assisted and unloaded 20-m sprints within a single session. 20-m sprint times and step velocity, as well as step length, step frequency, contact and flight times of each step were evaluated for each condition with a laser gun and an infrared mat. Almost all measured parameters were altered for each step under the resisted and assisted sprint conditions (η 2 ≥ 0.28). The exception was step frequency, which did not differ between assisted and normal sprints. Contact time, flight time and step frequency at almost each step were different between 'fast' vs. 'slow' sub-groups (η 2 ≥ 0.22). Nevertheless overall both groups responded similarly to the respective sprint conditions. No significant differences in step length were observed between groups for the respective condition. It is possible that continued exposure to assisted sprinting might allow the female team-sports players studied to adapt their coordination to the 'over-speed' condition and increase step frequency. It is notable that step-by-step kinematics in these sprints were easy to obtain using relatively inexpensive equipment with possibilities of direct feedback.
Heinz, Dirk W
2013-12-03
Secretins are major constituents of bacterial type III secretion systems (T3SS). In this issue of Structure, Kowal and colleagues report on the cryo-EM structure of the native YscC secretin from Yersinia, revealing its internal symmetry and mode of length adaptation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Planning energy-efficient bipedal locomotion on patterned terrain
NASA Astrophysics Data System (ADS)
Zamani, Ali; Bhounsule, Pranav A.; Taha, Ahmad
2016-05-01
Energy-efficient bipedal walking is essential in realizing practical bipedal systems. However, current energy-efficient bipedal robots (e.g., passive-dynamics-inspired robots) are limited to walking at a single speed and step length. The objective of this work is to address this gap by developing a method of synthesizing energy-efficient bipedal locomotion on patterned terrain consisting of stepping stones using energy-efficient primitives. A model of Cornell Ranger (a passive-dynamics inspired robot) is utilized to illustrate our technique. First, an energy-optimal trajectory control problem for a single step is formulated and solved. The solution minimizes the Total Cost Of Transport (TCOT is defined as the energy used per unit weight per unit distance travelled) subject to various constraints such as actuator limits, foot scuffing, joint kinematic limits, ground reaction forces. The outcome of the optimization scheme is a table of TCOT values as a function of step length and step velocity. Next, we parameterize the terrain to identify the location of the stepping stones. Finally, the TCOT table is used in conjunction with the parameterized terrain to plan an energy-efficient stepping strategy.
Estimated splash and training wall height requirements for stepped chutes applied to embankment dams
USDA-ARS?s Scientific Manuscript database
Aging embankment dams are commonly plagued with insufficient spillway capacity. To provide increased spillway capacity, stepped chutes are frequently applied as an overtopping protection system for embankment dams. Stepped chutes with sufficient length develops aerated flow. The aeration and flow...
Ormeci, A; Emrence, Z; Baran, B; Gokturk, S; Soyer, O M; Evirgen, S; Akyuz, F; Karaca, C; Besisik, F; Kaymakoglu, S; Ustek, D; Demir, K
2016-03-01
Cytochrome P450 2C19 (CYP2C19) polymorphisms play an important role in the metabolism of proton pump inhibitors. Rabeprazole is primarily metabolized via non-enzymatic pathways. In this study, we determined whether rabeprazole- and pantoprazole-based eradication treatments were influenced by CYP2C19 polymorphisms. A total of 200 patients infected with Helicobacter pylori were treated with either 40 mg of pantoprazole or 20 mg of rabeprazole plus 500 mg of clarithromycin, 1000 mg of amoxicillin twice daily for 2 weeks. CYP2C19 genotype status was determined by Polymerase Chain Reaction (PCR)-restriction-fragment-length polymorphism. The genotypes of cytochrome P450 2C19 were classified as homozigote extensive metabolizer (HomEM), heterozigote metabolizer (HetEM) and poor metabolizer (PM). The CYP2C19 genotype of all patients, the effectiveness of the treatment, the effect of the genotypic polymorphism on the treatment were assessed. The frequencies of HotEM, HetEM, PM were 78%, 19.5% and 2.5%, respectively. 48% (n = 96) of the patients received treatment with rabeprazole and 52% (n = 104) with pantoprazole. The eradication rate was 64.7% for HomEM, 79.4% for HetEM, 100% for PM (p = 0.06). In HetEM, PM, are considered as a single group, the eradication rates were higher in patients with the HetEM and PM (HetEM+PM) genotypes than in those with the wild-type genotype (81.8 vs. 64.7% p = 0.031). Among the patients treated with rabeprazole, the eradication rates were significantly lower in those with the HomEM genotype than in those with the HetEM+PM genotypes (60% vs. 85.7% p = 0.023). The genotypic polymorphism is effective on the rate of eradication. Eradication treatment rate with rabeprazole is influenced by CYP2C19 genotype.
Patocka, Catherine; Turner, Joel; Wiseman, Jeffrey
2015-11-01
There is no evidence-based description of electrocardiogram (ECG) interpretation competencies for emergency medicine (EM) trainees. The first step in defining these competencies is to develop a prioritized list of adult ECG findings relevant to EM contexts. The purpose of this study was to categorize the importance of various adult ECG diagnoses and/or findings for the EM trainee. We developed a list of potentially important adult ECG diagnoses/findings and conducted a Delphi opinion-soliciting process. Participants used a 4-point Likert scale to rate the importance of each diagnosis for EM trainees. Consensus was defined as a minimum of 75% agreement at the second round or later. In the absence of consensus, stability was defined as a shift of 20% or less after successive rounds. A purposive sampling of 22 emergency physicians participated in the Delphi process, and 16 (72%) completed the process. Of those, 15 were from 11 different EM training programs across Canada and one was an expert in EM electrocardiography. Overall, 78 diagnoses reached consensus, 42 achieved stability and one diagnosis achieved neither consensus nor stability. Out of 121 potentially important adult ECG diagnoses, 53 (44%) were considered "must know" diagnoses, 61 (50%) "should know" diagnoses, and 7 (6%) "nice to know" diagnoses. We have categorized adult ECG diagnoses within an EM training context, knowledge of which may allow clinical EM teachers to establish educational priorities. This categorization will also facilitate the development of an educational framework to establish EM trainee competency in ECG interpretation.
Joint Prior Learning for Visual Sensor Network Noisy Image Super-Resolution
Yue, Bo; Wang, Shuang; Liang, Xuefeng; Jiao, Licheng; Xu, Caijin
2016-01-01
The visual sensor network (VSN), a new type of wireless sensor network composed of low-cost wireless camera nodes, is being applied for numerous complex visual analyses in wild environments, such as visual surveillance, object recognition, etc. However, the captured images/videos are often low resolution with noise. Such visual data cannot be directly delivered to the advanced visual analysis. In this paper, we propose a joint-prior image super-resolution (JPISR) method using expectation maximization (EM) algorithm to improve VSN image quality. Unlike conventional methods that only focus on upscaling images, JPISR alternatively solves upscaling mapping and denoising in the E-step and M-step. To meet the requirement of the M-step, we introduce a novel non-local group-sparsity image filtering method to learn the explicit prior and induce the geometric duality between images to learn the implicit prior. The EM algorithm inherently combines the explicit prior and implicit prior by joint learning. Moreover, JPISR does not rely on large external datasets for training, which is much more practical in a VSN. Extensive experiments show that JPISR outperforms five state-of-the-art methods in terms of both PSNR, SSIM and visual perception. PMID:26927114
Buckle, Tessa; van Willigen, Danny M; Spa, Silvia J; Hensbergen, Albertus W; van der Wal, Steffen; de Korne, Clarize M; Welling, Mick M; van der Poel, Henk G; Hardwick, James C H; van Leeuwen, Fijs W B
2018-02-15
Objectives: The potential of (receptor-mediated) fluorescence-based image-guided surgery tracers is generally linked to the near-infrared emission profile and good manufacturing production (GMP) availability of fluorescent dyes. Surprisingly, little is known about the critical interaction between the structural composition of the dye and the pharmacokinetics of the tracers. In this study, a bimodal/hybrid tracer design was used to systematically and quantitatively evaluate the influence of elongation of the polymethine chain in a fluorescent cyanine (Cy) dye on the imaging potential of a targeted (RGD-based) tracer. Methods: As model system, the integrin marker ανβ3 was targeted using c[RGDyK] vectors functionalized with a ( 111 In-)DTPA chelate and a fluorescent dye (Cy3-(SO3)Methyl-COOH (λem 580nm), Cy5-(SO3)Methyl-COOH (λem 680nm), or Cy7-(SO3)Methyl-COOH (λem 780nm)). Tracers were analyzed for differences in (photo-) physical properties, serum protein binding, chemical/optical stability and signal penetration through tissue. Receptor affinities (KD) were evaluated using saturation and competition experiments. In vivo biodistribution (SPECT imaging and percentage injected dose per gram of tissue (%ID/g)) was assessed in tumor-bearing mice and complimented with in- and ex vivo fluorescence images obtained using a clinical grade multispectral fluorescence laparoscope. Results: Two carbon-atom-step variations in the polymethine chain of the fluorescent Cy-dyes were shown to significantly influence the chemical and photophysical characteristics e.g. stability, brightness and tissue penetration of the hybrid RGD-tracers. Herein DTPA-Cy5-(SO3)Methyl-COOH-c[RGDyK] systematically outperformed its Cy3- and Cy7- derivatives. Radioactivity-based evaluation of in vivo tracer pharmacokinetics yielded the lowest non-specific uptake and highest tumor-to-background ratio (T/B) for DTPA-Cy5-(SO3)Methyl-COOH-c[RGDyK] (13.2 ± 1.7), with the Cy3- and Cy7- analogs trailing at a respective T/B of 5.7 ± 0.7 and 4.7 ± 0.7. Fluorescence-based assessment of the tumor visibility revealed a similar trend. Conclusion: These findings underline that variations in the polymethine chain lengths of Cy dyes have a profound influence on the photophysical properties, stability and in vivo targeting capabilities of fluorescent imaging tracers. In a direct comparison the intermediate length dye (Cy5) yielded a superior c[RGDyK] -tracer compared to the shorter (Cy3-) and longer (Cy7-) analogs. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Random sampling of elementary flux modes in large-scale metabolic networks.
Machado, Daniel; Soons, Zita; Patil, Kiran Raosaheb; Ferreira, Eugénio C; Rocha, Isabel
2012-09-15
The description of a metabolic network in terms of elementary (flux) modes (EMs) provides an important framework for metabolic pathway analysis. However, their application to large networks has been hampered by the combinatorial explosion in the number of modes. In this work, we develop a method for generating random samples of EMs without computing the whole set. Our algorithm is an adaptation of the canonical basis approach, where we add an additional filtering step which, at each iteration, selects a random subset of the new combinations of modes. In order to obtain an unbiased sample, all candidates are assigned the same probability of getting selected. This approach avoids the exponential growth of the number of modes during computation, thus generating a random sample of the complete set of EMs within reasonable time. We generated samples of different sizes for a metabolic network of Escherichia coli, and observed that they preserve several properties of the full EM set. It is also shown that EM sampling can be used for rational strain design. A well distributed sample, that is representative of the complete set of EMs, should be suitable to most EM-based methods for analysis and optimization of metabolic networks. Source code for a cross-platform implementation in Python is freely available at http://code.google.com/p/emsampler. dmachado@deb.uminho.pt Supplementary data are available at Bioinformatics online.
Guide to Developing an Environmental Management System - Do
This page takes you though the basic steps (Plan, Do, Check, Act) of building an Environmental Management System (EMS) as they are outlined in the 2001 Second Edition of Environmental Management Systems: An Implementation Guide. This is the Do section.
Time Management and the Woman Library Manager.
ERIC Educational Resources Information Center
Gothberg, Helen M.
1987-01-01
Discusses how women library managers can use efficient time management techniques to help them make the best of both career and home work environments. Nine basic steps to greater efficiency are presented, and external and internal time wasters are listed. (EM)
The effect of cane use on the compensatory step following posterior perturbations.
Hall, Courtney D; Jensen, Jody L
2004-08-01
The compensatory step is a critical component of the balance response and is impaired in older fallers. The purpose of this research was to examine whether utilization of a cane modified the compensatory step response following external posterior perturbations. Single subject withdrawal design was employed. Single subject statistical analysis--the standard deviation bandwidth-method--supplemented visual analysis of the data. Four older adults (range: 73-83 years) with balance impairment who habitually use a cane completed this study. Subjects received a series of sudden backward pulls that were large enough to elicit compensatory stepping. We examined the following variables both with and without cane use: timing of cane loading relative to step initiation and center of mass acceleration, stability margin, center of mass excursion and velocity, step length and width. No participant loaded the cane prior to initiation of the first compensatory step. There was no effect of cane use on the stability margin, nor was there an effect of cane use on center of mass excursion or velocity, or step length or width. These data suggest that cane use does not necessarily improve balance recovery following an external posterior perturbation when the individual is forced to rely on compensatory stepping. Instead these data suggest that the strongest factor in modifying step characteristics is experience with the perturbation.
Hansen, Andrew H; Meier, Margrit R; Sessoms, Pinata H; Childress, Dudley S
2006-12-01
The Shape&Roll prosthetic foot was used to examine the effect of roll-over shape arc length on the gait of 14 unilateral trans-tibial prosthesis users. Simple modifications to the prosthetic foot were used to alter the effective forefoot rocker length, leaving factors such as alignment, limb length, and heel and mid-foot characteristics unchanged. Shortening the roll-over shape arc length caused a significant reduction in the maximum external dorsiflexion moment on the prosthetic side at all walking speeds (p < 0.001 for main effect of arc length), due to a reduction in forefoot leverage (moment arm) about the ankle. Roll-over shape arc length significantly affected the initial loading on the sound limb at normal and fast speeds (p = 0.001 for the main effect of arc length), with participants experiencing larger first peaks of vertical ground reaction forces on their sound limbs when using the foot with the shortest effective forefoot rocker arc length. Additionally, the difference between step lengths on the sound and prosthetic limbs was larger with the shortest arc length condition, although this difference was not statistically significant (p = 0.06 for main effect). It appears that prosthesis users may experience a drop-off effect at the end of single limb stance on prosthetic feet with short roll-over shape arc lengths, leading to increased loading and/or a shortened step on the contralateral limb.
Nnodim, Joseph O; Strasburg, Debra; Nabozny, Martina; Nyquist, Linda; Galecki, Andrzej; Chen, Shu; Alexander, Neil B
2006-12-01
To compare the effect of two 10-week balance training programs, Combined Balance and Step Training (CBST) versus tai chi (TC), on balance and stepping measures. Prospective intervention trial. Local senior centers and congregate housing facilities. Aged 65 and older with at least mild impairment in the ability to perform unipedal stance and tandem walk. Participants were allocated to TC (n = 107, mean age 78) or CBST, an intervention focused on improving dynamic balance and stepping (n = 106, mean age 78). At baseline and 10 weeks, participants were tested in their static balance (Unipedal Stance and Tandem Stance (TS)), stepping (Maximum Step Length, Rapid Step Test), and Timed Up and Go (TUG). Performance improved more with CBST than TC, ranging from 5% to 10% for the stepping tests (Maximum Step Length and Rapid Step Test) and 9% for TUG. The improvement in TUG represented an improvement of more than 1 second. Greater improvements were also seen in static balance ability (in TS) with CBST than TC. Of the two training programs, in which variants of each program have been proven to reduce falls, CBST results in modest improvements in balance, stepping, and functional mobility versus TC over a 10-week period. Future research should include a prospective comparison of fall rates in response to these two balance training programs.
Monolithic Microfluidic Mixing-Spraying Devices for Time-Resolved Cryo-Electron Microscopy
Lu, Zonghuan; Shaikh, Tanvir R.; Barnard, David; Meng, Xing; Mohamed, Hisham; Yassin, Aymen; Mannella, Carmen A.; Agrawal, Rajendra K.; Lu, Toh-Ming
2009-01-01
The goal of time-resolved cryo-electron microscopy is to determine structural models for transient functional states of large macromolecular complexes such as ribosomes and viruses. The challenge of time-resolved cryo-electron microscopy is to rapidly mix reactants, and then, following a defined time interval, to rapidly deposit them as a thin film and freeze the sample to the vitreous state. Here we describe a methodology in which reaction components are mixed and allowed to react, and are then sprayed onto an EM grid as it is being plunged into cryogen. All steps are accomplished by a monolithic, microfabricated silicon device that incorporates a mixer, reaction channel, and pneumatic sprayer in a single chip. We have found that microdroplets produced by air atomization spread to sufficiently thin films on a millisecond time scale provided that the carbon supporting film is made suitably hydrophilic. The device incorporates two T-mixers flowing into a single channel of four butterfly-shaped mixing elements that ensure effective mixing, followed by a microfluidic reaction channel whose length can be varied to achieve the desired reaction time. The reaction channel is flanked by two ports connected to compressed humidified nitrogen gas (at 50 psi) to generate the spray. The monolithic mixer-sprayer is incorporated into a computer-controlled plunging apparatus. To test the mixing performance and the suitability of the device for preparation of biological macromolecules for cryo-EM, ribosomes and ferritin were mixed in the device and sprayed onto grids. Three-dimensional reconstructions of the ribosomes demonstrated retention of native structure, and 30S and 50S subunits were shown to be capable of reassociation into ribosomes after passage through the device. PMID:19683579
Shani, Guy; Shapiro, Amir; Oded, Goldstein; Dima, Kagan; Melzer, Itshak
2017-01-01
Rapid compensatory stepping plays an important role in preventing falls when balance is lost; however, these responses cannot be accurately quantified in the clinic. The Microsoft Kinect™ system provides real-time anatomical landmark position data in three dimensions (3D), which may bridge this gap. Compensatory stepping reactions were evoked in 8 young adults by a sudden platform horizontal motion on which the subject stood or walked on a treadmill. The movements were recorded with both a 3D-APAS motion capture and Microsoft Kinect™ systems. The outcome measures consisted of compensatory step times (milliseconds) and length (centimeters). The average values of two standing and walking trials for Microsoft Kinect™ and the 3D-APAS systems were compared using t -test, Pearson's correlation, Altman-bland plots, and the average difference of root mean square error (RMSE) of joint position. The Microsoft Kinect™ had high correlations for the compensatory step times ( r = 0.75-0.78, p = 0.04) during standing and moderate correlations for walking ( r = 0.53-0.63, p = 0.05). The step length, however had a very high correlations for both standing and walking ( r > 0.97, p = 0.01). The RMSE showed acceptable differences during the perturbation trials with smallest relative error in anterior-posterior direction (2-3%) and the highest in the vertical direction (11-13%). No systematic bias were evident in the Bland and Altman graphs. The Microsoft Kinect™ system provides comparable data to a video-based 3D motion analysis system when assessing step length and less accurate but still clinically acceptable for step times during balance recovery when balance is lost and fall is initiated.
Konik, Anita; Kuklewicz, Stanisław; Rosłoniec, Ewelina; Zając, Marcin; Spannbauer, Anna; Nowobilski, Roman; Mika, Piotr
2016-01-01
The purpose of the study was to evaluate selected temporal and spatial gait parameters in patients with intermittent claudication after completion of 12-week supervised treadmill walking training. The study included 36 patients (26 males and 10 females) aged: mean 64 (SD 7.7) with intermittent claudication. All patients were tested on treadmill (Gait Trainer, Biodex). Before the programme and after its completion, the following gait biomechanical parameters were tested: step length (cm), step cycle (cycle/s), leg support time (%), coefficient of step variation (%) as well as pain-free walking time (PFWT) and maximal walking time (MWT) were measured. Training was conducted in accordance with the current TASC II guidelines. After 12 weeks of training, patients showed significant change in gait biomechanics consisting in decreased frequency of step cycle (p < 0.05) and extended step length (p < 0.05). PFWT increased by 96% (p < 0.05). MWT increased by 100% (p < 0.05). After completing the training, patients' gait was more regular, which was expressed via statistically significant decrease of coefficient of variation (p < 0.05) for both legs. No statistically significant relation between the post-training improvement of PFWT and MWT and step length increase and decreased frequency of step cycle was observed (p > 0.05). Twelve-week treadmill walking training programme may lead to significant improvement of temporal and spatial gait parameters in patients with intermittent claudication. Twelve-week treadmill walking training programme may lead to significant improvement of pain-free walking time and maximum walking time in patients with intermittent claudication.
Balasubramanian, Chitralakshmi K.; Neptune, Richard R.; Kautz, Steven A.
2010-01-01
Background Foot placement during walking is closely linked to the body position, yet it is typically quantified relative to the other foot. The purpose of this study was to quantify foot placement patterns relative to body post-stroke and investigate its relationship to hemiparetic walking performance. Methods Thirty-nine participants with hemiparesis walked on a split-belt treadmill at their self-selected speeds and twenty healthy participants walked at matched slow speeds. Anterior-posterior and medial-lateral foot placements (foot center-of-mass) relative to body (pelvis center-of-mass) quantified stepping in body reference frame. Walking performance was quantified using step length asymmetry ratio, percent of paretic propulsion and paretic weight support. Findings Participants with hemiparesis placed their paretic foot further anterior than posterior during walking compared to controls walking at matched slow speeds (p < .05). Participants also placed their paretic foot further lateral relative to pelvis than non-paretic (p < .05). Anterior-posterior asymmetry correlated with step length asymmetry and percent paretic propulsion but some persons revealed differing asymmetry patterns in the translating reference frame. Lateral foot placement asymmetry correlated with paretic weight support (r = .596; p < .001), whereas step widths showed no relation to paretic weight support. Interpretation Post-stroke gait is asymmetric when quantifying foot placement in a body reference frame and this asymmetry related to the hemiparetic walking performance and explained motor control mechanisms beyond those explained by step lengths and step widths alone. We suggest that biomechanical analyses quantifying stepping performance in impaired populations should investigate foot placement in a body reference frame. PMID:20193972
Balasubramanian, Chitralakshmi K; Neptune, Richard R; Kautz, Steven A
2010-06-01
Foot placement during walking is closely linked to the body position, yet it is typically quantified relative to the other foot. The purpose of this study was to quantify foot placement patterns relative to body post-stroke and investigate its relationship to hemiparetic walking performance. Thirty-nine participants with hemiparesis walked on a split-belt treadmill at their self-selected speeds and 20 healthy participants walked at matched slow speeds. Anterior-posterior and medial-lateral foot placements (foot center-of-mass) relative to body (pelvis center-of-mass) quantified stepping in body reference frame. Walking performance was quantified using step length asymmetry ratio, percent of paretic propulsion and paretic weight support. Participants with hemiparesis placed their paretic foot further anterior than posterior during walking compared to controls walking at matched slow speeds (P<.05). Participants also placed their paretic foot further lateral relative to pelvis than non-paretic (P<.05). Anterior-posterior asymmetry correlated with step length asymmetry and percent paretic propulsion but some persons revealed differing asymmetry patterns in the translating reference frame. Lateral foot placement asymmetry correlated with paretic weight support (r=.596; P<.001), whereas step widths showed no relation to paretic weight support. Post-stroke gait is asymmetric when quantifying foot placement in a body reference frame and this asymmetry related to the hemiparetic walking performance and explained motor control mechanisms beyond those explained by step lengths and step widths alone. We suggest that biomechanical analyses quantifying stepping performance in impaired populations should investigate foot placement in a body reference frame. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Electron microscopy using the genetically encoded APEX2 tag in cultured mammalian cells
Martell, Jeffrey D; Deerinck, Thomas J; Lam, Stephanie S; Ellisman, Mark H; Ting, Alice Y
2018-01-01
Electron microscopy (EM) is the premiere technique for high-resolution imaging of cellular ultrastructure. Unambiguous identification of specific proteins or cellular compartments in electron micrographs, however, remains challenging because of difficulties in delivering electron-dense contrast agents to specific subcellular targets within intact cells. We recently reported enhanced ascorbate peroxidase 2 (APEX2) as a broadly applicable genetic tag that generates EM contrast on a specific protein or subcellular compartment of interest. This protocol provides guidelines for designing and validating APEX2 fusion constructs, along with detailed instructions for cell culture, transfection, fixation, heavy-metal staining, embedding in resin, and EM imaging. Although this protocol focuses on EM in cultured mammalian cells, APEX2 is applicable to many cell types and contexts, including intact tissues and organisms, and is useful for numerous applications beyond EM, including live-cell proteomic mapping. This protocol, which describes procedures for sample preparation from cell monolayers and cell pellets, can be completed in 10 d, including time for APEX2 fusion construct validation, cell growth, and solidification of embedding resins. Notably, the only additional steps required relative to a standard EM sample preparation are cell transfection and a 2- to 45-min staining period with 3,3′-diaminobenzidine (DAB) and hydrogen peroxide (H2O2). PMID:28796234
Rúa, Megan A; Lamit, Louis J; Gehring, Catherine; Antunes, Pedro M; Hoeksema, Jason D; Zabinski, Cathy; Karst, Justine; Burns, Cole; Woods, Michaela J
2018-02-01
Local adaptation, the differential success of genotypes in their native versus foreign environments, can influence ecological and evolutionary processes, yet its importance is difficult to estimate because it has not been widely studied, particularly in the context of interspecific interactions. Interactions between ectomycorrhizal (EM) fungi and their host plants could serve as model system for investigations of local adaptation because they are widespread and affect plant responses to both biotic and abiotic selection pressures. Furthermore, because EM fungi cycle nutrients and mediate energy flow into food webs, their local adaptation may be critical in sustaining ecological function. Despite their ecological importance and an extensive literature on their relationships with plants, the vast majority of experiments on EM symbioses fail to report critical information needed to assess local adaptation: the geographic origin of the plant, fungal inocula, and soil substrate used in the experiment. These omissions limit the utility of such studies and restrict our understanding of EM ecology and evolution. Here, we illustrate the potential importance of local adaptation in EM relationships and call for consistent reporting of the geographic origin of plant, soil, and fungi as an important step towards a better understanding of the ecology and evolution of EM symbioses.
Giant amplification in degenerate band edge slow-wave structures interacting with an electron beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Othman, Mohamed A. K.; Veysi, Mehdi; Capolino, Filippo
2016-03-15
We propose a new amplification regime based on a synchronous operation of four degenerate electromagnetic (EM) modes in a slow-wave structure and the electron beam, referred to as super synchronization. These four EM modes arise in a Fabry-Pérot cavity when degenerate band edge (DBE) condition is satisfied. The modes interact constructively with the electron beam resulting in superior amplification. In particular, much larger gains are achieved for smaller beam currents compared to conventional structures based on synchronization with only a single EM mode. We demonstrate giant gain scaling with respect to the length of the slow-wave structure compared to conventionalmore » Pierce type single mode traveling wave tube amplifiers. We construct a coupled transmission line model for a loaded waveguide slow-wave structure exhibiting a DBE, and investigate the phenomenon of giant gain via super synchronization using the Pierce model generalized to multimode interaction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sogin, H.H.; Goldstein, R.J.
1960-02-01
Experiments were performed on mass transfer by forced convection from naphthalene strips on a flat plate to an air stream at ordinary temperature and pressure. Turbulence was induced in the boundary layer by means of a wire strip. In all cases there was a hydrodynamic starting length upstream of the strips. The ratio of this inert length to the total length was varied from about 0.80 to 0.96. The flow was practically incompressible with Reynolds number, based on the total length, varying from 175,000 to 486,000. The Schmidt number was 2.5. The experimental results fell in proximity to the Sebanmore » step function factor when they were reduced after the massmomentum analysis of Deissler and Loeffler for a surface of uniform vapor pressure. When Karman's formulation of the mass- momentum analogy was assumed, the data fell between the values predicted by the Seban and by the Rubesin expression for the step function factor. The results were well correlated by the Colburn analogy in conjunction with the Rubesin step function factor. (auth)« less
Effects of age and step length on joint kinetics during stepping task.
Bieryla, Kathleen A; Buffinton, Christine
2015-07-16
Following a balance perturbation, a stepping response is commonly used to regain support, and the distance of the recovery step can vary. To date, no other studies have examined joint kinetics in young and old adults during increasing step distances, when participants are required to bring their rear foot forward. Therefore, the purpose of this study was to examine age-related differences in joint kinetics with increasing step distance. Twenty young and 20 old adults completed the study. Participants completed a step starting from double support, at an initial distance equal to the individual's average step length. The distance was increased by 10% body height until an unsuccessful attempt. A one-way, repeated measures ANOVA was used to determine the effects of age on joint kinetics during the maximum step distance. A two-way, repeated measures, mixed model ANOVA was used to determine the effects of age, step distance, and their interaction on joint kinetics during the first three step distances for all participants. Young adults completed a significantly longer step than old adults. During the maximum step, in general, kinetic measures were greater in the young than in the old. As step distance increased, all but one kinetic measure increased for both young and old adults. This study has shown the ability to discriminate between young and old adults, and could potentially be used in the future to distinguish between fallers and non-fallers. Copyright © 2015 Elsevier Ltd. All rights reserved.
Output power stability of a HCN laser using a stepping motor for the EAST interferometer system
NASA Astrophysics Data System (ADS)
Zhang, J. B.; Wei, X. C.; Liu, H. Q.; Shen, J. J.; Zeng, L.; Jie, Y. X.
2015-11-01
The HCN laser on EAST is a continuous wave glow discharge laser with 3.4 m cavity length and 120 mW power output at 337 μ m wavelength. Without a temperature-controlled system, the cavity length of the laser is very sensitive to the environmental temperature. An external power feedback control system is applied on the HCN laser to stabilize the laser output power. The feedback system is composed of a stepping motor, a PLC, a supervisory computer, and the corresponding control program. One step distance of the stepping motor is 1 μ m and the time response is 0.5 s. Based on the power feedback control system, a stable discharge for the HCN laser is obtained more than eight hours, which satisfies the EAST experiment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, L; Yin, F; Cai, J
Purpose: To develop a methodology of constructing physiological-based virtual thorax phantom based on hyperpolarized (HP) gas tagging MRI for evaluating deformable image registration (DIR). Methods: Three healthy subjects were imaged at both the end-of-inhalation (EOI) and the end-of-exhalation (EOE) phases using a high-resolution (2.5mm isovoxel) 3D proton MRI, as well as a hybrid MRI which combines HP gas tagging MRI and a low-resolution (4.5mm isovoxel) proton MRI. A sparse tagging displacement vector field (tDVF) was derived from the HP gas tagging MRI by tracking the displacement of tagging grids between EOI and EOE. Using the tDVF and the high-resolution MRmore » images, we determined the motion model of the entire thorax in the following two steps: 1) the DVF inside of lungs was estimated based on the sparse tDVF using a novel multi-step natural neighbor interpolation method; 2) the DVF outside of lungs was estimated from the DIR between the EOI and EOE images (Velocity AI). The derived motion model was then applied to the high-resolution EOI image to create a deformed EOE image, forming the virtual phantom where the motion model provides the ground truth of deformation. Five DIR methods were evaluated using the developed virtual phantom. Errors in DVF magnitude (Em) and angle (Ea) were determined and compared for each DIR method. Results: Among the five DIR methods, free form deformation produced DVF results that are most closely resembling the ground truth (Em=1.04mm, Ea=6.63°). The two DIR methods based on B-spline produced comparable results (Em=2.04mm, Ea=13.66°; and Em =2.62mm, Ea=17.67°), and the two optical-flow methods produced least accurate results (Em=7.8mm; Ea=53.04°; Em=4.45mm, Ea=31.02°). Conclusion: A methodology for constructing physiological-based virtual thorax phantom based on HP gas tagging MRI has been developed. Initial evaluation demonstrated its potential as an effective tool for robust evaluation of DIR in the lung.« less
Vector Graph Assisted Pedestrian Dead Reckoning Using an Unconstrained Smartphone
Qian, Jiuchao; Pei, Ling; Ma, Jiabin; Ying, Rendong; Liu, Peilin
2015-01-01
The paper presents a hybrid indoor positioning solution based on a pedestrian dead reckoning (PDR) approach using built-in sensors on a smartphone. To address the challenges of flexible and complex contexts of carrying a phone while walking, a robust step detection algorithm based on motion-awareness has been proposed. Given the fact that step length is influenced by different motion states, an adaptive step length estimation algorithm based on motion recognition is developed. Heading estimation is carried out by an attitude acquisition algorithm, which contains a two-phase filter to mitigate the distortion of magnetic anomalies. In order to estimate the heading for an unconstrained smartphone, principal component analysis (PCA) of acceleration is applied to determine the offset between the orientation of smartphone and the actual heading of a pedestrian. Moreover, a particle filter with vector graph assisted particle weighting is introduced to correct the deviation in step length and heading estimation. Extensive field tests, including four contexts of carrying a phone, have been conducted in an office building to verify the performance of the proposed algorithm. Test results show that the proposed algorithm can achieve sub-meter mean error in all contexts. PMID:25738763
Freedland, Robert L; Festa, Carmel; Sealy, Marita; McBean, Andrew; Elghazaly, Paul; Capan, Ariel; Brozycki, Lori; Nelson, Arthur J; Rothman, Jeffrey
2002-01-01
The purpose of this study was to examine the Functional Ambulation Performance Score (FAP; a quantitative gait measure) in persons with Parkinson's Disease (PD) using the auditory stimulation of a metronome (ASM). Participants (n = 16; 5F/11M; range 60--84 yrs.) had a primary diagnosis of PD and were all independent ambulators. Footfall data were collected while participants walked multiple times on an electronic walkway under the following conditions: 1) PRETEST: establishing baseline cadence, 2) ASM: metronome set to baseline cadence, 3) 10ASM: metronome set to 10% FAP scores increased between PRETEST and POSTTEST. PRE/POSTTEST comparisons also indicated decreases in cycle time and double support and increases in step length and step-extremity ratio (step length/leg length). The results confirm prior findings that auditory stimulation can be used to positively influence the gait of persons with PD and suggest beneficial effects of ASM as an adjunct to dopaminergic therapy to treat gait dysfunctions in PD.
Flexible mini gamma camera reconstructions of extended sources using step and shoot and list mode.
Gardiazabal, José; Matthies, Philipp; Vogel, Jakob; Frisch, Benjamin; Navab, Nassir; Ziegler, Sibylle; Lasser, Tobias
2016-12-01
Hand- and robot-guided mini gamma cameras have been introduced for the acquisition of single-photon emission computed tomography (SPECT) images. Less cumbersome than whole-body scanners, they allow for a fast acquisition of the radioactivity distribution, for example, to differentiate cancerous from hormonally hyperactive lesions inside the thyroid. This work compares acquisition protocols and reconstruction algorithms in an attempt to identify the most suitable approach for fast acquisition and efficient image reconstruction, suitable for localization of extended sources, such as lesions inside the thyroid. Our setup consists of a mini gamma camera with precise tracking information provided by a robotic arm, which also provides reproducible positioning for our experiments. Based on a realistic phantom of the thyroid including hot and cold nodules as well as background radioactivity, the authors compare "step and shoot" (SAS) and continuous data (CD) acquisition protocols in combination with two different statistical reconstruction methods: maximum-likelihood expectation-maximization (ML-EM) for time-integrated count values and list-mode expectation-maximization (LM-EM) for individually detected gamma rays. In addition, the authors simulate lower uptake values by statistically subsampling the experimental data in order to study the behavior of their approach without changing other aspects of the acquired data. All compared methods yield suitable results, resolving the hot nodules and the cold nodule from the background. However, the CD acquisition is twice as fast as the SAS acquisition, while yielding better coverage of the thyroid phantom, resulting in qualitatively more accurate reconstructions of the isthmus between the lobes. For CD acquisitions, the LM-EM reconstruction method is preferable, as it yields comparable image quality to ML-EM at significantly higher speeds, on average by an order of magnitude. This work identifies CD acquisition protocols combined with LM-EM reconstruction as a prime candidate for the wider introduction of SPECT imaging with flexible mini gamma cameras in the clinical practice.
Personal Equipment and Clothing Correction Factors for the Australian Army: A Pilot Survey
2014-11-01
Sitting M24 Fit Thigh Clearance M12 Clearance and Fit, DHM Knee Height, Sitting M13 Fit, DHM Popliteal Height M14 Fit, DHM Buttock-Knee Length...Measure Semi-Nude Definition Encumbered Definition EM28 Knee Height, Sitting Footrest surface to Suprapatella ( M13 ). Footrest surface to
Length and time for development of laminar flow in tubes following a step increase of volume flux
NASA Astrophysics Data System (ADS)
Chaudhury, Rafeed A.; Herrmann, Marcus; Frakes, David H.; Adrian, Ronald J.
2015-01-01
Laminar flows starting up from rest in round tubes are relevant to numerous industrial and biomedical applications. The two most common types are flows driven by an abruptly imposed constant pressure gradient or by an abruptly imposed constant volume flux. Analytical solutions are available for transient, fully developed flows, wherein streamwise development over the entrance length is absent (Szymanski in J de Mathématiques Pures et Appliquées 11:67-107, 1932; Andersson and Tiseth in Chem Eng Commun 112(1):121-133, 1992, respectively). They represent the transient responses of flows in tubes that are very long compared with the entrance length, a condition that is seldom satisfied in biomedical tube networks. This study establishes the entrance (development) length and development time of starting laminar flow in a round tube of finite length driven by a piston pump that produces a step change from zero flow to a constant volume flux for Reynolds numbers between 500 and 3,000. The flows are examined experimentally, using stereographic particle image velocimetry and computationally using computational fluid dynamics, and are then compared with the known analytical solutions for fully developed flow conditions in infinitely long tubes. Results show that step function volume flux start-up flows reach steady state and fully developed flow five times more quickly than those driven by a step function pressure gradient, a 500 % change when compared with existing estimates. Based on these results, we present new, simple guidelines for achieving experimental flows that are fully developed in space and time in realistic (finite) tube geometries. To a first approximation, the time to achieve steady spatially developing flow is nearly equal to the time needed to achieve steady, fully developed flow. Conversely, the entrance length needed to achieve fully developed transient flow is approximately equal to the length needed to achieve fully developed steady flow. Beyond this level of description, the numerical results reveal interaction between the effects of space and time development and nonlinear Reynolds number effects.
Maestas, Gabrielle; Hu, Jiyao; Trevino, Jessica; Chunduru, Pranathi; Kim, Seung-Jae; Lee, Hyunglae
2018-01-01
The use of visual feedback in gait rehabilitation has been suggested to promote recovery of locomotor function by incorporating interactive visual components. Our prior work demonstrated that visual feedback distortion of changes in step length symmetry entails an implicit or unconscious adaptive process in the subjects’ spatial gait patterns. We investigated whether the effect of the implicit visual feedback distortion would persist at three different walking speeds (slow, self-preferred and fast speeds) and how different walking speeds would affect the amount of adaption. In the visual feedback distortion paradigm, visual vertical bars portraying subjects’ step lengths were distorted so that subjects perceived their step lengths to be asymmetric during testing. Measuring the adjustments in step length during the experiment showed that healthy subjects made spontaneous modulations away from actual symmetry in response to the implicit visual distortion, no matter the walking speed. In all walking scenarios, the effects of implicit distortion became more significant at higher distortion levels. In addition, the amount of adaptation induced by the visual distortion was significantly greater during walking at preferred or slow speed than at the fast speed. These findings indicate that although a link exists between supraspinal function through visual system and human locomotion, sensory feedback control for locomotion is speed-dependent. Ultimately, our results support the concept that implicit visual feedback can act as a dominant form of feedback in gait modulation, regardless of speed. PMID:29632481
DeepPicker: A deep learning approach for fully automated particle picking in cryo-EM.
Wang, Feng; Gong, Huichao; Liu, Gaochao; Li, Meijing; Yan, Chuangye; Xia, Tian; Li, Xueming; Zeng, Jianyang
2016-09-01
Particle picking is a time-consuming step in single-particle analysis and often requires significant interventions from users, which has become a bottleneck for future automated electron cryo-microscopy (cryo-EM). Here we report a deep learning framework, called DeepPicker, to address this problem and fill the current gaps toward a fully automated cryo-EM pipeline. DeepPicker employs a novel cross-molecule training strategy to capture common features of particles from previously-analyzed micrographs, and thus does not require any human intervention during particle picking. Tests on the recently-published cryo-EM data of three complexes have demonstrated that our deep learning based scheme can successfully accomplish the human-level particle picking process and identify a sufficient number of particles that are comparable to those picked manually by human experts. These results indicate that DeepPicker can provide a practically useful tool to significantly reduce the time and manual effort spent in single-particle analysis and thus greatly facilitate high-resolution cryo-EM structure determination. DeepPicker is released as an open-source program, which can be downloaded from https://github.com/nejyeah/DeepPicker-python. Copyright © 2016 Elsevier Inc. All rights reserved.
Calibration of 3D ultrasound to an electromagnetic tracking system
NASA Astrophysics Data System (ADS)
Lang, Andrew; Parthasarathy, Vijay; Jain, Ameet
2011-03-01
The use of electromagnetic (EM) tracking is an important guidance tool that can be used to aid procedures requiring accurate localization such as needle injections or catheter guidance. Using EM tracking, the information from different modalities can be easily combined using pre-procedural calibration information. These calibrations are performed individually, per modality, allowing different imaging systems to be mixed and matched according to the procedure at hand. In this work, a framework for the calibration of a 3D transesophageal echocardiography probe to EM tracking is developed. The complete calibration framework includes three required steps: data acquisition, needle segmentation, and calibration. Ultrasound (US) images of an EM tracked needle must be acquired with the position of the needles in each volume subsequently extracted by segmentation. The calibration transformation is determined through a registration between the segmented points and the recorded EM needle positions. Additionally, the speed of sound is compensated for since calibration is performed in water that has a different speed then is assumed by the US machine. A statistical validation framework has also been developed to provide further information related to the accuracy and consistency of the calibration. Further validation of the calibration showed an accuracy of 1.39 mm.
Da Rocha, Emmanuel S; Kunzler, Marcos R; Bobbert, Maarten F; Duysens, Jacques; Carpes, Felipe P
2018-06-01
Walking is one of the preferred exercises among elderly, but could a prolonged walking increase gait variability, a risk factor for a fall in the elderly? Here we determine whether 30 min of treadmill walking increases coefficient of variation of gait in elderly. Because gait responses to exercise depend on fitness level, we included 15 sedentary and 15 active elderly. Sedentary participants preferred a lower gait speed and made smaller steps than the actives. Step length coefficient of variation decreased ~16.9% by the end of the exercise in both the groups. Stride length coefficient of variation decreased ~9% after 10 minutes of walking, and sedentary elderly showed a slightly larger step width coefficient of variation (~2%) at 10 min than active elderly. Active elderly showed higher walk ratio (step length/cadence) than sedentary in all times of walking, but the times did not differ in both the groups. In conclusion, treadmill gait kinematics differ between sedentary and active elderly, but changes over time are similar in sedentary and active elderly. As a practical implication, 30 min of walking might be a good strategy of exercise for elderly, independently of the fitness level, because it did not increase variability in step and stride kinematics, which is considered a risk of fall in this population.
2-D modelling and simulation of EM brake for liquid steel
NASA Astrophysics Data System (ADS)
Aslan, Necdet; Senturk, Kenan; Tessarotto, Massimo
2003-11-01
The problem of EM control of bottom tapping in steelmaking metallurgy is an old and well known challenge not only from the technological viewpoint but also, potentially, an interesting and still open theoretical problem, from the viewpoint of the investigation of the detailed MHD phenomena occurring in EM braking devices [1]. Purpose of the present work is the formulation of a 2-D MHD model for a DC EM braking device, which includes the consistent modelization of inductive EM fields produced by the conductive fluid, large scale turbulence, boundary conditions for the EM fields and thermal effects. The mathematical model has been implemented in a new 2-D MHD code developed for this purpose [2], based on the so-called fluctuation splitting and dual-time stepping methods, respectively, to advance in time the fluid fields and satisfy the relevant incompressibility-solenoidality conditions for the fluid mass velocity and the magnetic field. Main goal of the investigation is the analysis of the nonlinear phenomena occurring in the process of slowing down of a column of liquid steel under the action of the EM brake, and in particular the detailed description of the effects of large scale turbulence produced by the action of Lorentz force on the fluid, their influence on the magnitude of the inductive EM fields and the performance of the EM brake itself. REFERENCES [1] A.Codutti, A.Martinis, M.Pavlicevic, M.Tessarotto and D.Batic, Proc. 3rd International Symposium on EMP (Nagoya, Japan, April 2000), p.530 (2000). [2] N.Aslan, K.Senturk and M.Tessarotto, Efficient 2-D solver for incompressible magnefluids, communication at this Conference (2003).
Yang, Zhiwei; Gou, Lu; Chen, Shuyu; Li, Na; Zhang, Shengli; Zhang, Lei
2017-01-01
Membrane fusion is one of the most fundamental physiological processes in eukaryotes for triggering the fusion of lipid and content, as well as the neurotransmission. However, the architecture features of neurotransmitter release machinery and interdependent mechanism of synaptic membrane fusion have not been extensively studied. This review article expounds the neuronal membrane fusion processes, discusses the fundamental steps in all fusion reactions (membrane aggregation, membrane association, lipid rearrangement and lipid and content mixing) and the probable mechanism coupling to the delivery of neurotransmitters. Subsequently, this work summarizes the research on the fusion process in synaptic transmission, using electron microscopy (EM) and molecular simulation approaches. Finally, we propose the future outlook for more exciting applications of membrane fusion involved in synaptic transmission, with the aid of stochastic optical reconstruction microscopy (STORM), cryo-EM (cryo-EM), and molecular simulations. PMID:28638320
Viewing Angle Classification of Cryo-Electron Microscopy Images Using Eigenvectors
Singer, A.; Zhao, Z.; Shkolnisky, Y.; Hadani, R.
2012-01-01
The cryo-electron microscopy (cryo-EM) reconstruction problem is to find the three-dimensional structure of a macromolecule given noisy versions of its two-dimensional projection images at unknown random directions. We introduce a new algorithm for identifying noisy cryo-EM images of nearby viewing angles. This identification is an important first step in three-dimensional structure determination of macromolecules from cryo-EM, because once identified, these images can be rotationally aligned and averaged to produce “class averages” of better quality. The main advantage of our algorithm is its extreme robustness to noise. The algorithm is also very efficient in terms of running time and memory requirements, because it is based on the computation of the top few eigenvectors of a specially designed sparse Hermitian matrix. These advantages are demonstrated in numerous numerical experiments. PMID:22506089
Wang, Ling; Muralikrishnan, Bala; Rachakonda, Prem; Sawyer, Daniel
2017-01-01
Terrestrial laser scanners (TLS) are increasingly used in large-scale manufacturing and assembly where required measurement uncertainties are on the order of few tenths of a millimeter or smaller. In order to meet these stringent requirements, systematic errors within a TLS are compensated in-situ through self-calibration. In the Network method of self-calibration, numerous targets distributed in the work-volume are measured from multiple locations with the TLS to determine parameters of the TLS error model. In this paper, we propose two new self-calibration methods, the Two-face method and the Length-consistency method. The Length-consistency method is proposed as a more efficient way of realizing the Network method where the length between any pair of targets from multiple TLS positions are compared to determine TLS model parameters. The Two-face method is a two-step process. In the first step, many model parameters are determined directly from the difference between front-face and back-face measurements of targets distributed in the work volume. In the second step, all remaining model parameters are determined through the Length-consistency method. We compare the Two-face method, the Length-consistency method, and the Network method in terms of the uncertainties in the model parameters, and demonstrate the validity of our techniques using a calibrated scale bar and front-face back-face target measurements. The clear advantage of these self-calibration methods is that a reference instrument or calibrated artifacts are not required, thus significantly lowering the cost involved in the calibration process. PMID:28890607
Emergency medical service (EMS): A unique flight environment
NASA Technical Reports Server (NTRS)
Shively, R. Jay
1993-01-01
The EMS flight environment is unique in today's aviation. The pilots must respond quickly to emergency events and often fly to landing zones where they have never been before . The time from initially receiving a call to being airborne can be as little as two to three minutes. Often the EMS pilot is the only aviation professional on site, they have no operations people or other pilots to aid them in making decisons. Further, since they are often flying to accident scenes, not airports, there is often complete weather and condition information. Therefore, the initial decision that the pilot must make, accepting or declining a flight, can become very difficult. The accident rate of EMS helicopters has been relatively high over the past years. NASA-Ames research center has taken several steps in an attempt to aid EMS pilots in their decision making and situational awareness. A preflight risk assessment system (SAFE) was developed to aid pilots in their decision making, and was tested at an EMS service. The resutls of the study were promising and a second version incorporating the lessons learned is under development. A second line of research was the development of a low cost electronic chart display (ECD). This is a digital map display to help pilots maintain geographical orientation. Another thrust was undertaken in conjunction with the Aviation Safety Reporting System (ASRS). This involved publicizing the ASRS to EMS pilots and personnel, and calling each of the reporters back to gather additional information. This paper will discuss these efforts and how they may positively impact the safety of EMS operations.
Comparison of step-by-step kinematics in repeated 30m sprints in female soccer players.
van den Tillaar, Roland
2018-01-04
The aim of this study was to compare kinematics in repeated 30m sprints in female soccer players. Seventeen subjects performed seven 30m sprints every 30s in one session. Kinematics were measured with an infrared contact mat and laser gun, and running times with an electronic timing device. The main findings were that sprint times increased in the repeated sprint ability test. The main changes in kinematics during the repeated sprint ability test were increased contact time and decreased step frequency, while no change in step length was observed. The step velocity increased in almost each step until the 14, which occurred around 22m. After this, the velocity was stable until the last step, when it decreased. This increase in step velocity was mainly caused by the increased step length and decreased contact times. It was concluded that the fatigue induced in repeated 30m sprints in female soccer players resulted in decreased step frequency and increased contact time. Employing this approach in combination with a laser gun and infrared mat for 30m makes it very easy to analyse running kinematics in repeated sprints in training. This extra information gives the athlete, coach and sports scientist the opportunity to give more detailed feedback and help to target these changes in kinematics better to enhance repeated sprint performance.
An Analysis of EMS and ED Detection of Stroke.
Medoro, Ian; Cone, David C
2017-01-01
Studies have shown a reduction in time-to-CT and improved process measures when EMS personnel notify the ED of a "stroke alert" from the field. However, there are few data on the accuracy of these EMS stroke alerts. The goal of this study was to examine diagnostic test performance of EMS and ED stroke alerts and related process measures. The EMS and ED records of all stroke alerts in a large tertiary ED from August 2013-January 2014 were examined and data abstracted by one trained investigator, with data accuracy confirmed by a second investigator for 15% of cases. Stroke alerts called by EMS prior to ED arrival were compared to stroke alerts called by ED physicians and nurses (for walk-in patients, and patients transported by EMS without EMS stroke alerts). Means ± SD, medians, unpaired t-tests (for continuous data), and two-tailed Fisher's exact tests (for categorical data) were used. Of 260 consecutive stroke alerts, 129 were EMS stroke alerts, and 131 were ED stroke alerts (70 called by physicians, 61 by nurses). The mean NIH Stroke Scale was higher in the EMS group (8.1 ± 7.6 vs. 3.0 ± 5.0, p < 0.0001). The positive predictive value of EMS stroke alerts was 0.60 (78/129), alerts by ED nurses was 0.25 (15/61), and alerts by ED physicians was 0.31 (22/70). The PPV for EMS was better than for nurses or physicians (both p < 0.001), and more patients in the EMS group had final diagnoses of stroke (62/129 vs. 24/131, p < 0.001). The positive likelihood ratio was 1.53 for EMS personnel, 0.45 for physicians, and 0.77 for nurses. The mean time to order the CT (8.5 ± 7.1 min vs. 23.1 ± 18.2 min, p < 0.0001) and the mean ED length of stay (248 ± 116 min vs. 283 ± 128 min, p = 0.022) were shorter for the EMS stroke alert group. More EMS stroke alert patients received tPA (16/129 vs. 6/131, p = 0.027). EMS stroke alerts have better diagnostic test performance than stroke alerts by ED staff, likely due to higher NIH Stroke Scale scores (more obvious presentations) and are associated with better process measures. The fairly low PPV suggests room for improvement in prehospital stroke protocols.
Model Predictive Control-based gait pattern generation for wearable exoskeletons.
Wang, Letian; van Asseldonk, Edwin H F; van der Kooij, Herman
2011-01-01
This paper introduces a new method for controlling wearable exoskeletons that do not need predefined joint trajectories. Instead, it only needs basic gait descriptors such as step length, swing duration, and walking speed. End point Model Predictive Control (MPC) is used to generate the online joint trajectories based on these gait parameters. Real-time ability and control performance of the method during the swing phase of gait cycle is studied in this paper. Experiments are performed by helping a human subject swing his leg with different patterns in the LOPES gait trainer. Results show that the method is able to assist subjects to make steps with different step length and step duration without predefined joint trajectories and is fast enough for real-time implementation. Future study of the method will focus on controlling the exoskeletons in the entire gait cycle. © 2011 IEEE
An implementation of the look-ahead Lanczos algorithm for non-Hermitian matrices, part 1
NASA Technical Reports Server (NTRS)
Freund, Roland W.; Gutknecht, Martin H.; Nachtigal, Noel M.
1990-01-01
The nonsymmetric Lanczos method can be used to compute eigenvalues of large sparse non-Hermitian matrices or to solve large sparse non-Hermitian linear systems. However, the original Lanczos algorithm is susceptible to possible breakdowns and potential instabilities. We present an implementation of a look-ahead version of the Lanczos algorithm which overcomes these problems by skipping over those steps in which a breakdown or near-breakdown would occur in the standard process. The proposed algorithm can handle look-ahead steps of any length and is not restricted to steps of length 2, as earlier implementations are. Also, our implementation has the feature that it requires roughly the same number of inner products as the standard Lanczos process without look-ahead.
Controllable 3D architectures of aligned carbon nanotube arrays by multi-step processes
NASA Astrophysics Data System (ADS)
Huang, Shaoming
2003-06-01
An effective way to fabricate large area three-dimensional (3D) aligned CNTs pattern based on pyrolysis of iron(II) phthalocyanine (FePc) by two-step processes is reported. The controllable generation of different lengths and selective growth of the aligned CNT arrays on metal-patterned (e.g., Ag and Au) substrate are the bases for generating such 3D aligned CNTs architectures. By controlling experimental conditions 3D aligned CNT arrays with different lengths/densities and morphologies/structures as well as multi-layered architectures can be fabricated in large scale by multi-step pyrolysis of FePc. These 3D architectures could have interesting properties and be applied for developing novel nanotube-based devices.
Olenšek, Andrej; Zadravec, Matjaž; Matjačić, Zlatko
2016-06-11
The most common approach to studying dynamic balance during walking is by applying perturbations. Previous studies that investigated dynamic balance responses predominantly focused on applying perturbations in frontal plane while walking on treadmill. The goal of our work was to develop balance assessment robot (BAR) that can be used during overground walking and to assess normative balance responses to perturbations in transversal plane in a group of neurologically healthy individuals. BAR provides three passive degrees of freedom (DoF) and three actuated DoF in pelvis that are admittance-controlled in such a way that the natural movement of pelvis is not significantly affected. In this study BAR was used to assess normative balance responses in neurologically healthy individuals by applying linear perturbations in frontal and sagittal planes and angular perturbations in transversal plane of pelvis. One way repeated measure ANOVA was used to statistically evaluate the effect of selected perturbations on stepping responses. Standard deviations of assessed responses were similar in unperturbed and perturbed walking. Perturbations in frontal direction evoked substantial pelvis displacement and caused statistically significant effect on step length, step width and step time. Likewise, perturbations in sagittal plane also caused statistically significant effect on step length, step width and step time but with less explicit impact on pelvis movement in frontal plane. On the other hand, except from substantial pelvis rotation angular perturbations did not have substantial effect on pelvis movement in frontal and sagittal planes while statistically significant effect was noted only in step length and step width after perturbation in clockwise direction. Results indicate that the proposed device can repeatedly reproduce similar experimental conditions. Results also suggest that "stepping strategy" is the dominant strategy for coping with perturbations in frontal plane, perturbations in sagittal plane are to greater extent handled by "ankle strategy" while angular perturbations in transversal plane do not pose substantial challenge for balance. Results also show that specific perturbation in general elicits responses that extend also to other planes of movement that are not directly associated with plane of perturbation as well as to spatio temporal parameters of gait.
Asymmetry of short-term control of spatio-temporal gait parameters during treadmill walking
NASA Astrophysics Data System (ADS)
Kozlowska, Klaudia; Latka, Miroslaw; West, Bruce J.
2017-03-01
Optimization of energy cost determines average values of spatio-temporal gait parameters such as step duration, step length or step speed. However, during walking, humans need to adapt these parameters at every step to respond to exogenous and/or endogenic perturbations. While some neurological mechanisms that trigger these responses are known, our understanding of the fundamental principles governing step-by-step adaptation remains elusive. We determined the gait parameters of 20 healthy subjects with right-foot preference during treadmill walking at speeds of 1.1, 1.4 and 1.7 m/s. We found that when the value of the gait parameter was conspicuously greater (smaller) than the mean value, it was either followed immediately by a smaller (greater) value of the contralateral leg (interleg control), or the deviation from the mean value decreased during the next movement of ipsilateral leg (intraleg control). The selection of step duration and the selection of step length during such transient control events were performed in unique ways. We quantified the symmetry of short-term control of gait parameters and observed the significant dominance of the right leg in short-term control of all three parameters at higher speeds (1.4 and 1.7 m/s).
Domain ordering of strained 5 ML SrTiO3 films on Si(001)
NASA Astrophysics Data System (ADS)
Ryan, P.; Wermeille, D.; Kim, J. W.; Woicik, J. C.; Hellberg, C. S.; Li, H.
2007-05-01
High resolution x-ray diffraction data indicate ordered square shaped coherent domains, ˜1200Å in length, coexisting with longer, ˜9500Å correlated regions in highly strained 5 ML SrTiO3 films grown on Si(001). These long range film structures are due to the Si substrate terraces defined by the surface step morphology. The silicon surface "step pattern" is comprised of an "intrinsic" terrace length from strain relaxation and a longer "extrinsic" interstep distance due to the surface miscut.
Maximum Likelihood Estimation of Nonlinear Structural Equation Models.
ERIC Educational Resources Information Center
Lee, Sik-Yum; Zhu, Hong-Tu
2002-01-01
Developed an EM type algorithm for maximum likelihood estimation of a general nonlinear structural equation model in which the E-step is completed by a Metropolis-Hastings algorithm. Illustrated the methodology with results from a simulation study and two real examples using data from previous studies. (SLD)
Electromagnetic characterization of layered biaxial media is a critical step in the design of modern low observable (LO) coatings, and with the...the flexibility they provide for control over magnitude, phase, and polarization of the material systems response to interrogating electromagnetic (EM
Patel, Prakruti J; Bhatt, Tanvi
2016-10-01
We examined whether aging with and without a cerebral lesion such as stroke affects modulation of reactive balance response for recovery from increasing intensity of sudden slip-like stance perturbations. Ten young adults, older age-match adults and older chronic stroke survivors were exposed to three different levels of slip-like perturbations, level 1 (7.75m/s(2)), Level II (12.00m/s(2)) and level III (16.75m/s(2)) in stance. The center of mass (COM) state stability was computed as the shortest distance of the instantaneous COM position and velocity relative to base of support (BOS) from a theoretical threshold for backward loss of balance (BLOB). The COM position (XCOM/BOS) and velocity (ẊCOM/BOS) relative to BOS at compensatory step touchdown, compensatory step length and trunk angle at touchdown were also recorded. At liftoff, stability reduced with increasing perturbation intensity across all groups (main effect of intensity p<0.05). At touchdown, while the young group showed a linear improvement in stability with increasing perturbation intensity, such a trend was absent in other groups (intensity×group interaction, p<0.05). Between-group differences in stability at touchdown were thus observed at levels II and III. Further, greater stability at touchdown positively correlated with anterior XCOM/BOS however not with ẊCOM/BOS. Young adults maintained anterior XCOM/BOS by increasing compensatory step length and preventing greater trunk extension at higher perturbation intensities. The age-match group attempted to increase step length from intensity I to II to maintain stability however could not further increase step length at intensity III, resulting in lower stability on this level compared with the young group. Stroke group on the other hand was unable to modulate compensatory step length or control trunk extension at higher perturbation intensities resulting in reduced stability on levels II and III compared with the other groups. The findings reflect impaired modulation of recovery response with increasing intensity of sudden perturbations among stroke survivors compared with their healthy counter parts. Thus, aging superimposed with a cortical lesion could further impair reactive balance control, potentially contributing toward a higher fall risk in older stroke survivors. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-22
...-step method for determining the status of fish stocks in the Southeast Region. SEDAR is a three step... information on life history characteristics, catch statistics, discard estimates, length and age composition...
Cryo-EM image alignment based on nonuniform fast Fourier transform.
Yang, Zhengfan; Penczek, Pawel A
2008-08-01
In single particle analysis, two-dimensional (2-D) alignment is a fundamental step intended to put into register various particle projections of biological macromolecules collected at the electron microscope. The efficiency and quality of three-dimensional (3-D) structure reconstruction largely depends on the computational speed and alignment accuracy of this crucial step. In order to improve the performance of alignment, we introduce a new method that takes advantage of the highly accurate interpolation scheme based on the gridding method, a version of the nonuniform fast Fourier transform, and utilizes a multi-dimensional optimization algorithm for the refinement of the orientation parameters. Using simulated data, we demonstrate that by using less than half of the sample points and taking twice the runtime, our new 2-D alignment method achieves dramatically better alignment accuracy than that based on quadratic interpolation. We also apply our method to image to volume registration, the key step in the single particle EM structure refinement protocol. We find that in this case the accuracy of the method not only surpasses the accuracy of the commonly used real-space implementation, but results are achieved in much shorter time, making gridding-based alignment a perfect candidate for efficient structure determination in single particle analysis.
Cryo-EM Image Alignment Based on Nonuniform Fast Fourier Transform
Yang, Zhengfan; Penczek, Pawel A.
2008-01-01
In single particle analysis, two-dimensional (2-D) alignment is a fundamental step intended to put into register various particle projections of biological macromolecules collected at the electron microscope. The efficiency and quality of three-dimensional (3-D) structure reconstruction largely depends on the computational speed and alignment accuracy of this crucial step. In order to improve the performance of alignment, we introduce a new method that takes advantage of the highly accurate interpolation scheme based on the gridding method, a version of the nonuniform Fast Fourier Transform, and utilizes a multi-dimensional optimization algorithm for the refinement of the orientation parameters. Using simulated data, we demonstrate that by using less than half of the sample points and taking twice the runtime, our new 2-D alignment method achieves dramatically better alignment accuracy than that based on quadratic interpolation. We also apply our method to image to volume registration, the key step in the single particle EM structure refinement protocol. We find that in this case the accuracy of the method not only surpasses the accuracy of the commonly used real-space implementation, but results are achieved in much shorter time, making gridding-based alignment a perfect candidate for efficient structure determination in single particle analysis. PMID:18499351
Approximate, computationally efficient online learning in Bayesian spiking neurons.
Kuhlmann, Levin; Hauser-Raspe, Michael; Manton, Jonathan H; Grayden, David B; Tapson, Jonathan; van Schaik, André
2014-03-01
Bayesian spiking neurons (BSNs) provide a probabilistic interpretation of how neurons perform inference and learning. Online learning in BSNs typically involves parameter estimation based on maximum-likelihood expectation-maximization (ML-EM) which is computationally slow and limits the potential of studying networks of BSNs. An online learning algorithm, fast learning (FL), is presented that is more computationally efficient than the benchmark ML-EM for a fixed number of time steps as the number of inputs to a BSN increases (e.g., 16.5 times faster run times for 20 inputs). Although ML-EM appears to converge 2.0 to 3.6 times faster than FL, the computational cost of ML-EM means that ML-EM takes longer to simulate to convergence than FL. FL also provides reasonable convergence performance that is robust to initialization of parameter estimates that are far from the true parameter values. However, parameter estimation depends on the range of true parameter values. Nevertheless, for a physiologically meaningful range of parameter values, FL gives very good average estimation accuracy, despite its approximate nature. The FL algorithm therefore provides an efficient tool, complementary to ML-EM, for exploring BSN networks in more detail in order to better understand their biological relevance. Moreover, the simplicity of the FL algorithm means it can be easily implemented in neuromorphic VLSI such that one can take advantage of the energy-efficient spike coding of BSNs.
Borzooeian, Zahra; Taslim, Mohammad E; Ghasemi, Omid; Rezvani, Saina; Borzooeian, Giti; Nourbakhsh, Amirhasan
2018-01-01
Parametric separation of carbon nanotubes, especially based on their length is a challenge for a number of nano-tech researchers. We demonstrate a method to combine bio-conjugation, SDS-PAGE, and silver staining in order to separate carbon nanotubes on the basis of length. Egg-white lysozyme, conjugated covalently onto the single-walled carbon nanotubes surfaces using carbodiimide method. The proposed conjugation of a biomolecule onto the carbon nanotubes surfaces is a novel idea and a significant step forward for creating an indicator for length-based carbon nanotubes separation. The conjugation step was followed by SDS-PAGE and the nanotube fragments were precisely visualized using silver staining. This high precision, inexpensive, rapid and simple separation method obviates the need for centrifugation, additional chemical analyses, and expensive spectroscopic techniques such as Raman spectroscopy to visualize carbon nanotube bands. In this method, we measured the length of nanotubes using different image analysis techniques which is based on a simplified hydrodynamic model. The method has high precision and resolution and is effective in separating the nanotubes by length which would be a valuable quality control tool for the manufacture of carbon nanotubes of specific lengths in bulk quantities. To this end, we were also able to measure the carbon nanotubes of different length, produced from different sonication time intervals.
Tarantino, Mary E; Bilotti, Katharina; Huang, Ji; Delaney, Sarah
2015-08-21
Flap endonuclease 1 (FEN1) is a structure-specific nuclease responsible for removing 5'-flaps formed during Okazaki fragment maturation and long patch base excision repair. In this work, we use rapid quench flow techniques to examine the rates of 5'-flap removal on DNA substrates of varying length and sequence. Of particular interest are flaps containing trinucleotide repeats (TNR), which have been proposed to affect FEN1 activity and cause genetic instability. We report that FEN1 processes substrates containing flaps of 30 nucleotides or fewer at comparable single-turnover rates. However, for flaps longer than 30 nucleotides, FEN1 kinetically discriminates substrates based on flap length and flap sequence. In particular, FEN1 removes flaps containing TNR sequences at a rate slower than mixed sequence flaps of the same length. Furthermore, multiple-turnover kinetic analysis reveals that the rate-determining step of FEN1 switches as a function of flap length from product release to chemistry (or a step prior to chemistry). These results provide a kinetic perspective on the role of FEN1 in DNA replication and repair and contribute to our understanding of FEN1 in mediating genetic instability of TNR sequences. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
A new method for the adjustment of neochordal length: the adjustable slip knot technique.
Yano, Mitsuhiro; Sakaguchi, Syuuhei; Furukawa, Kohji; Nakamura, Eisaku
2015-08-01
The use of expanded polytetrafluoroethylene (ePTFE) sutures for the correction of mitral valve prolapse has become a standardized procedure. Adjustment of neochordal length is crucial to the efficacy of this technique. Various methods have been described for this purpose; however, the fine adjustment of neochordal length is technically challenging. We describe a simple and effective technique for the implantation of neochordae, which we have termed the 'adjustable slip knot technique'. The first step of this technique is reinforcement of the papillary muscle by a Teflon pledget with or without polytetrafluoroethylene (CV-4) loops. The second step is the formation of a neochordal loop by introducing an ePTFE suture between the affected mitral leaflet and the papillary muscle or ePTFE loops. The third step is the adjustment of the length of neochordae. The formation of a slip knot in one arm of the ePTFE suture is the pivot of this technique. The neochordal loop can be constricted by the application of tension to one arm of the suture. We applied this technique in 5 patients with satisfactory results. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Rui, Jing; Runge, M Brett; Spinner, Robert J; Yaszemski, Michael J; Windebank, Anthony J; Wang, Huan
2014-10-01
Video-assisted gait kinetics analysis has been a sensitive method to assess rat sciatic nerve function after injury and repair. However, in conduit repair of sciatic nerve defects, previously reported kinematic measurements failed to be a sensitive indicator because of the inferior recovery and inevitable joint contracture. This study aimed to explore the role of physiotherapy in mitigating joint contracture and to seek motion analysis indices that can sensitively reflect motor function. Data were collected from 26 rats that underwent sciatic nerve transection and conduit repair. Regular postoperative physiotherapy was applied. Parameters regarding step length, phase duration, and ankle angle were acquired and analyzed from video recording of gait kinetics preoperatively and at regular postoperative intervals. Stride length ratio (step length of uninjured foot/step length of injured foot), percent swing of the normal paw (percentage of the total stride duration when the uninjured paw is in the air), propulsion angle (toe-off angle subtracted by midstance angle), and clearance angle (ankle angle change from toe off to midswing) decreased postoperatively comparing with baseline values. The gradual recovery of these measurements had a strong correlation with the post-nerve repair time course. Ankle joint contracture persisted despite rigorous physiotherapy. Parameters acquired from a 2-dimensional motion analysis system, that is, stride length ratio, percent swing of the normal paw, propulsion angle, and clearance angle, could sensitively reflect nerve function impairment and recovery in the rat sciatic nerve conduit repair model despite the existence of joint contractures.
Liu, Zhiyi; Zhang, Luyao; Liu, Yanling; Gu, Yang; Sun, Tieliang
2017-11-01
We aimed to evaluate the efficiency and safety of one-step procedure combined endoscopic retrograde cholangiopancreatography (ERCP) and laparoscopic cholecystectomy (LC) for treatment of patients with cholecysto-choledocholithiasis. A prospective randomized study was performed on 63 consecutive cholecysto-choledocholithiasis patients during 2008 and 2011. The efficiency and safety of one-step procedure was assessed by comparing the two-step LC with ERCP + endoscopic sphincterotomy (EST). Outcomes including intraoperative features, postoperative features (length of stay and postoperative complications) were evaluated. One- or two-step procedure of LC with ERCP + EST was successfully performed in all patients, and common bile duct stones were completely removed. Statistical analyses showed that length of stay and pulmonary infection rate were significantly lower in the test group compared with that in the control group (P < 0.05), whereas no statistical difference in other outcomes was found between the two groups (all P > 0.05). The one-step procedure of LC with ERCP + EST is superior to the two-step procedure for treatment of patients with cholecysto-choledocholithiasis regarding to the reduced hospital stay and inhibited occurrence of pulmonary infections. Compared with two-step procedure, one-step procedure of LC with ERCP + EST may be a superior option for cholecysto-choledocholithiasis patients treatment regarding to hospital stay and pulmonary infections.
Rearfoot striking runners are more economical than midfoot strikers.
Ogueta-Alday, Ana; Rodríguez-Marroyo, José Antonio; García-López, Juan
2014-03-01
This study aimed to analyze the influence of foot strike pattern on running economy and biomechanical characteristics in subelite runners with a similar performance level. Twenty subelite long-distance runners participated and were divided into two groups according to their foot strike pattern: rearfoot (RF, n = 10) and midfoot (MF, n = 10) strikers. Anthropometric characteristics were measured (height, body mass, body mass index, skinfolds, circumferences, and lengths); physiological (VO2max, anaerobic threshold, and running economy) and biomechanical characteristics (contact and flight times, step rate, and step length) were registered during both incremental and submaximal tests on a treadmill. There were no significant intergroup differences in anthropometrics, VO2max, or anaerobic threshold measures. RF strikers were 5.4%, 9.3%, and 5.0% more economical than MF at submaximal speeds (11, 13, and 15 km·h respectively, although the difference was not significant at 15 km·h, P = 0.07). Step rate and step length were not different between groups, but RF showed longer contact time (P < 0.01) and shorter flight time (P < 0.01) than MF at all running speeds. The present study showed that habitually rearfoot striking runners are more economical than midfoot strikers. Foot strike pattern affected both contact and flight times, which may explain the differences in running economy.
Crenshaw, Jeremy R; Rosenblatt, Noah J; Hurt, Christopher P; Grabiner, Mark D
2012-01-03
This study evaluated the discriminant capability of stability measures, trunk kinematics, and step kinematics to classify successful and failed compensatory stepping responses. In addition, the shared variance between stability measures, step kinematics, and trunk kinematics is reported. The stability measures included the anteroposterior distance (d) between the body center of mass and the stepping limb toe, the margin of stability (MOS), as well as time-to-boundary considering velocity (TTB(v)), velocity and acceleration (TTB(a)), and MOS (TTB(MOS)). Kinematic measures included trunk flexion angle and angular velocity, step length, and the time after disturbance onset of recovery step completion. Fourteen young adults stood on a treadmill that delivered surface accelerations necessitating multiple forward compensatory steps. Thirteen subjects fell from an initial disturbance, but recovered from a second, identical disturbance. Trunk flexion velocity at completion of the first recovery step and trunk flexion angle at completion of the second step had the greatest overall classification of all measures (92.3%). TTB(v) and TTB(a) at completion of both steps had the greatest classification accuracy of all stability measures (80.8%). The length of the first recovery step (r ≤ 0.70) and trunk flexion angle at completion of the second recovery step (r ≤ -0.54) had the largest correlations with stability measures. Although TTB(v) and TTB(a) demonstrated somewhat smaller discriminant capabilities than trunk kinematics, the small correlations between these stability measures and trunk kinematics (|r| ≤ 0.52) suggest that they reflect two important, yet different, aspects of a compensatory stepping response. Copyright © 2011 Elsevier Ltd. All rights reserved.
de Kam, Digna; Roelofs, Jolanda M B; Geurts, Alexander C H; Weerdesteyn, Vivian
2018-01-01
To determine the predictive value of leg and trunk inclination angles at stepping-foot contact for the capacity to recover from a backward balance perturbation with a single step in people after stroke. Twenty-four chronic stroke survivors and 21 healthy controls were included in a cross-sectional study. We studied reactive stepping responses by subjecting participants to multidirectional stance perturbations at different intensities on a translating platform. In this paper we focus on backward perturbations. Participants were instructed to recover from the perturbations with maximally one step. A trial was classified as 'success' if balance was restored according to this instruction. We recorded full-body kinematics and computed: 1) body configuration parameters at first stepping-foot contact (leg and trunk inclination angles) and 2) spatiotemporal step parameters (step onset, step length, step duration and step velocity). We identified predictors of balance recovery capacity using a stepwise logistic regression. Perturbation intensity was also included as a predictor. The model with spatiotemporal parameters (perturbation intensity, step length and step duration) could correctly classify 85% of the trials as success or fail (Nagelkerke R2 = 0.61). In the body configuration model (Nagelkerke R2 = 0.71), perturbation intensity and leg and trunk angles correctly classified the outcome of 86% of the recovery attempts. The goodness of fit was significantly higher for the body configuration model compared to the model with spatiotemporal variables (p<0.01). Participant group and stepping leg (paretic or non-paretic) did not significantly improve the explained variance of the final body configuration model. Body configuration at stepping-foot contact is a valid and clinically feasible indicator of backward fall risk in stroke survivors, given its potential to be derived from a single sagittal screenshot.
Growth from Solutions: Kink dynamics, Stoichiometry, Face Kinetics and stability in turbulent flow
NASA Technical Reports Server (NTRS)
Chernov, A. A.; DeYoreo, J. J.; Rashkovich, L. N.; Vekilov, P. G.
2005-01-01
1. Kink dynamics. The first segment of a polygomized dislocation spiral step measured by AFM demonstrates up to 60% scattering in the critical length l*- the length when the segment starts to propagate. On orthorhombic lysozyme, this length is shorter than that the observed interkink distance. Step energy from the critical segment length based on the Gibbs-Thomson law (GTL), l* = 20(omega)alpha/(Delta)mu is several times larger than the energy from 2D nucleation rate. Here o is tine building block specific voiume, a is the step riser specific free energy, Delta(mu) is the crystallization driving force. These new data support our earlier assumption that the classical Frenkel, Burton -Cabrera-Frank concept of the abundant kink supply by fluctuations is not applicable for strongly polygonized steps. Step rate measurements on brushite confirms that statement. This is the1D nucleation of kinks that control step propagation. The GTL is valid only if l*
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-10-01
The US Department of Energy (DOE) Office of Environmental Management, formerly the Office of Environmental Restoration and Waste Management (EM), was established in November 1989 as the first step toward correcting contamination problems resulting from nearly 50 years of nuclear weapons production and fuel processing activities. EM consolidates several DOE organizations previously responsible for the handling, treatment, and disposition of radioactive and hazardous waste. Within EM, the Office of Technology Development (OTD/EM-50) is responsible for developing technologies to meet DOE`s goal for environmental restoration. OTD manages an aggressive national program of applied research, development, demonstration, testing, and evaluation (RDDT andmore » E) for environmental cleanup, waste management, and related technologies. The program is designed to resolve major technical issues, to rapidly advanced beyond current technologies for environmental restoration and waste management operations, and to expedite compliance with applicable environmental laws and regulations. This report summarizes Fiscal Year 1994 (FY94) programmatic information, accomplishments, and planned activities relevant to the individual activities within OTD`s RDDT and E.« less
NASA Technical Reports Server (NTRS)
Hom, K. W.
1994-01-01
The EM-ANIMATE program is a specialized visualization program that displays and animates the near-field and surface-current solutions obtained from an electromagnetics program, in particular, that from MOM3D (LAR-15074). The EM-ANIMATE program is windows based and contains a user-friendly, graphical interface for setting viewing options, case selection, file manipulation, etc. EM-ANIMATE displays the field and surface-current magnitude as smooth shaded color fields (color contours) ranging from a minimum contour value to a maximum contour value for the fields and surface currents. The program can display either the total electric field or the scattered electric field in either time-harmonic animation mode or in the root mean square (RMS) average mode. The default setting is initially set to the minimum and maximum values within the field and surface current data and can be optionally set by the user. The field and surface-current value are animated by calculating and viewing the solution at user selectable radian time increments between 0 and 2pi. The surface currents can also be displayed in either time-harmonic animation mode or in RMS average mode. In RMS mode, the color contours do not vary with time, but show the constant time averaged field and surface-current magnitude solution. The electric field and surface-current directions can be displayed as scaled vector arrows which have a length proportional to the magnitude at each field grid point or surface node point. These vector properties can be viewed separately or concurrently with the field or surface-current magnitudes. Animation speed is improved by turning off the display of the vector arrows. In RMS modes, the direction vectors are still displayed as varying with time since the time averaged direction vectors would be zero length vectors. Other surface properties can optionally be viewed. These include the surface grid, the resistance value assigned to each element of the grid, and the power dissipation of each element which has an assigned resistance value. The EM-ANIMATE program will accept up to 10 different surface current cases each consisting of up to 20,000 node points and 10,000 triangle definitions and will animate one of these cases. The capability is used to compare surface-current distribution due to various initial excitation directions or electric field orientations. The program can accept up to 50 planes of field data consisting of a grid of 100 by 100 field points. These planes of data are user selectable and can be viewed individually or concurrently. With these preset limits, the program requires 55 megabytes of core memory to run. These limits can be changed in the header files to accommodate the available core memory of an individual workstation. An estimate of memory required can be made as follows: approximate memory in bytes equals (number of nodes times number of surfaces times 14 variables times bytes per word, typically 4 bytes per floating point) plus (number of field planes times number of nodes per plane times 21 variables times bytes per word). This gives the approximate memory size required to store the field and surface-current data. The total memory size is approximately 400,000 bytes plus the data memory size. The animation calculations are performed in real time at any user set time step. For Silicon Graphics Workstations that have multiple processors, this program has been optimized to perform these calculations on multiple processors to increase animation rates. The optimized program uses the SGI PFA (Power FORTRAN Accelerator) library. On single processor machines, the parallelization directives are seen as comments to the program and will have no effect on compilation or execution. EM-ANIMATE is written in FORTRAN 77 for implementation on SGI IRIS workstations running IRIX 3.0 or later. A minimum of 55Mb of RAM is required for execution of this program; however, the code may be modified to accommodate the available memory of an individual workstation. For program execution, twenty-four bit, double-buffered color capability is suggested, but not required. Sample input and output files and a sample executable are provided on the distribution medium. Electronic documentation is provided in PostScript format and in the form of IRIX man pages. The standard distribution medium for EM-ANIMATE is a .25 inch streaming magnetic IRIX tape cartridge in UNIX tar format. EM-ANIMATE is also available as part of a bundled package, COS-10048 that includes MOM3D, an IRIS program that produces electromagnetic near field and surface current solutions. This program was developed in 1993.
Song, Hyun-Seob; Goldberg, Noam; Mahajan, Ashutosh; Ramkrishna, Doraiswami
2017-08-01
Elementary (flux) modes (EMs) have served as a valuable tool for investigating structural and functional properties of metabolic networks. Identification of the full set of EMs in genome-scale networks remains challenging due to combinatorial explosion of EMs in complex networks. It is often, however, that only a small subset of relevant EMs needs to be known, for which optimization-based sequential computation is a useful alternative. Most of the currently available methods along this line are based on the iterative use of mixed integer linear programming (MILP), the effectiveness of which significantly deteriorates as the number of iterations builds up. To alleviate the computational burden associated with the MILP implementation, we here present a novel optimization algorithm termed alternate integer linear programming (AILP). Our algorithm was designed to iteratively solve a pair of integer programming (IP) and linear programming (LP) to compute EMs in a sequential manner. In each step, the IP identifies a minimal subset of reactions, the deletion of which disables all previously identified EMs. Thus, a subsequent LP solution subject to this reaction deletion constraint becomes a distinct EM. In cases where no feasible LP solution is available, IP-derived reaction deletion sets represent minimal cut sets (MCSs). Despite the additional computation of MCSs, AILP achieved significant time reduction in computing EMs by orders of magnitude. The proposed AILP algorithm not only offers a computational advantage in the EM analysis of genome-scale networks, but also improves the understanding of the linkage between EMs and MCSs. The software is implemented in Matlab, and is provided as supplementary information . hyunseob.song@pnnl.gov. Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2017. This work is written by US Government employees and are in the public domain in the US.
Methodology for the development of a Canadian national EMS research agenda
2011-01-01
Background Many health care disciplines use evidence-based decision making to improve patient care and system performance. While the amount and quality of emergency medical services (EMS) research in Canada has increased over the past two decades, there has not been a unified national plan to enable research, ensure efficient use of research resources, guide funding decisions and build capacity in EMS research. Other countries have used research agendas to identify barriers and opportunities in EMS research and define national research priorities. The objective of this project is to develop a national EMS research agenda for Canada that will: 1) explore what barriers to EMS research currently exist, 2) identify current strengths and opportunities that may be of benefit to advancing EMS research, 3) make recommendations to overcome barriers and capitalize on opportunities, and 4) identify national EMS research priorities. Methods/Design Paramedics, educators, EMS managers, medical directors, researchers and other key stakeholders from across Canada will be purposefully recruited to participate in this mixed methods study, which consists of three phases: 1) qualitative interviews with a selection of the study participants, who will be asked about their experience and opinions about the four study objectives, 2) a facilitated roundtable discussion, in which all participants will explore and discuss the study objectives, and 3) an online Delphi consensus survey, in which all participants will be asked to score the importance of each topic discovered during the interviews and roundtable as they relate to the study objectives. Results will be analyzed to determine the level of consensus achieved for each topic. Discussion A mixed methods approach will be used to address the four study objectives. We anticipate that the keys to success will be: 1) ensuring a representative sample of EMS stakeholders, 2) fostering an open and collaborative roundtable discussion, and 3) adhering to a predefined approach to measure consensus on each topic. Steps have been taken in the methodology to address each of these a priori concerns. PMID:21961624
Lowry, Kristin A; Carrel, Andrew J; McIlrath, Jessica M; Smiley-Oyen, Ann L
2010-04-01
To determine if gait stability, as measured by harmonic ratios (HRs) derived from trunk accelerations, is improved during 3 amplitude-based cueing strategies (visual cues, lines on the floor 20% longer than preferred step length; verbal cues, experimenter saying "big step" every third; cognitive cues, participants think "big step") in people with Parkinson's disease. Gait analysis with a triaxial accelerometer. University research laboratory. A volunteer sample of persons with Parkinson's disease (N=7) (Hoehn and Yahr stages 2-3). Not applicable Gait stability was quantified by anterior-posterior (AP), vertical, and mediolateral (ML) HRs; higher ratios indicated improved gait stability. Spatiotemporal parameters assessed were walking speed, stride length, cadence, and the coefficient of variation for stride time. Of the amplitude-based cues, verbal and cognitive resulted in the largest improvements in the AP HR (P=.018) with a trend in the vertical HR as well as the largest improvements in both stride length and velocity. None of the cues positively affected stability in the ML direction. Descriptively, all participants increased speed and stride length, but only those in Hoehn and Yahr stage 2 (not Hoehn and Yahr stage 3) showed improvements in HRs. Cueing for "big steps" is effective for improving gait stability in the AP direction with modest improvements in the vertical direction, but it is not effective in the ML direction. These data support the use of trunk acceleration measures in assessing the efficacy of common therapeutic interventions. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Step length and individual anaerobic threshold assessment in swimming.
Fernandes, R J; Sousa, M; Machado, L; Vilas-Boas, J P
2011-12-01
Anaerobic threshold is widely used for diagnosis of swimming aerobic endurance but the precise incremental protocols step duration for its assessment is controversial. A physiological and biomechanical comparison between intermittent incremental protocols with different step lengths and a maximal lactate steady state (MLSS) test was conducted. 17 swimmers performed 7×200, 300 and 400 m (30 s and 24 h rest between steps and protocols) in front crawl until exhaustion and an MLSS test. The blood lactate concentration values ([La-]) at individual anaerobic threshold were 2.1±0.1, 2.2±0.2 and 1.8±0.1 mmol.l - 1 in the 200, 300 and 400 m protocols (with significant differences between 300 and 400 m tests), and 2.9±1.2 mmol.l - 1 at MLSS (higher than the incremental protocols); all these values are much lower than the traditional 4 mmol.l - 1 value. The velocities at individual anaerobic threshold obtained in incremental protocols were similar (and highly related) to the MLSS, being considerably lower than the velocity at 4 mmol.l - 1. Stroke rate increased and stroke length decreased throughout the different incremental protocols. It was concluded that it is valid to use intermittent incremental protocols of 200 and 300 m lengths to assess the swimming velocity corresponding to individual anaerobic threshold, the progressive protocols tend to underestimate the [La-] at anaerobic threshold assessed by the MLSS test, and swimmers increase velocity through stroke rate increases. © Georg Thieme Verlag KG Stuttgart · New York.
Education Scholarship and its Impact on Emergency Medicine Education.
Sherbino, Jonathan
2015-11-01
Emergency medicine (EM) education is becoming increasingly challenging as a result of changes to North American medical education and the growing complexity of EM practice. Education scholarship (ES) provides a process to develop solutions to these challenges. ES includes both research and innovation. ES is informed by theory, principles and best practices, is peer reviewed, and is disseminated and archived for others to use. Digital technologies have improved the discovery of work that informs ES, broadened the scope and timing of peer review, and provided new platforms for the dissemination and archiving of innovations. This editorial reviews key steps in raising an education innovation to the level of scholarship. It also discusses important areas for EM education scholars to address, which include the following: the delivery of competency-based medical education programs, the impact of social media on learning, and the redesign of continuing professional development.
Education Scholarship and its Impact on Emergency Medicine Education
Sherbino, Jonathan
2015-01-01
Emergency medicine (EM) education is becoming increasingly challenging as a result of changes to North American medical education and the growing complexity of EM practice. Education scholarship (ES) provides a process to develop solutions to these challenges. ES includes both research and innovation. ES is informed by theory, principles and best practices, is peer reviewed, and is disseminated and archived for others to use. Digital technologies have improved the discovery of work that informs ES, broadened the scope and timing of peer review, and provided new platforms for the dissemination and archiving of innovations. This editorial reviews key steps in raising an education innovation to the level of scholarship. It also discusses important areas for EM education scholars to address, which include the following: the delivery of competency-based medical education programs, the impact of social media on learning, and the redesign of continuing professional development. PMID:26594270
Clinical Gait Evaluation of Patients with Lumbar Spine Stenosis.
Sun, Jun; Liu, Yan-Cheng; Yan, Song-Hua; Wang, Sha-Sha; Lester, D Kevin; Zeng, Ji-Zhou; Miao, Jun; Zhang, Kuan
2018-02-01
The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients. Twelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high-speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t-test, intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plots were used for the data analysis. The ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P-values of paired t-tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001. The measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Dominici, Nadia; Daprati, Elena; Nico, Daniele; Cappellini, Germana; Ivanenko, Yuri P; Lacquaniti, Francesco
2009-03-01
When walking, step length provides critical information on traveled distance along the ongoing path [corrected] Little is known on the role that knowledge about body dimensions plays within this process. Here we directly addressed this question by evaluating whether changes in body proportions interfere with computation of traveled distance for targets located outside the reaching space. We studied locomotion and distance estimation in an achondroplastic child (ACH, 11 yr) before and after surgical elongation of the shank segments of both lower limbs and in healthy adults walking on stilts, designed to mimic shank-segment elongation. Kinematic analysis of gait revealed that dynamic coupling of the thigh, shank, and foot segments changed substantially as a result of elongation. Step length remained unvaried, in spite of the significant increase in total limb length ( approximately 1.5-fold). These relatively shorter strides resulted from smaller oscillations of the shank segment, as would be predicted by proportional increments in limb size and not by asymmetrical segmental increment as in the present case (length of thighs was not modified). Distance estimation was measured by walking with eyes closed toward a memorized target. Before surgery, the behavior of ACH was comparable to that of typically developing participants. In contrast, following shank elongation, the ACH walked significantly shorter distances when aiming at the same targets. Comparable changes in limb kinematics, stride length, and estimation of traveled distance were found in adults wearing on stilts, suggesting that path integration errors in both cases were related to alterations in the intersegmental coordination of the walking limbs. The results are consistent with a dynamic locomotor body schema used for controlling step length and path estimation, based on inherent relationships between gait parameters and body proportions.
Influence of gait speed on stability: recovery from anterior slips and compensatory stepping.
Bhatt, T; Wening, J D; Pai, Y-C
2005-02-01
Falls precipitated by slipping are a major health concern, with the majority of all slip-related falls occurring during gait. Recent evidence shows that a faster and/or more anteriorly positioned center of mass (COM) is more stable against backward balance loss, and that compensatory stepping is the key to recovering stability upon balance loss. The purposes of this paper were to determine whether walking speed affected gait stability for backward balance loss at slip onset and touchdown of compensatory stepping, and whether compensatory stepping response resembled the regular gait pattern. Forty-seven young subjects were slipped unexpectedly either at a self-selected fast, natural or slow speed. Speed-related differences in stability at slip onset and touchdown of the subsequent compensatory step were analyzed using the COM position-velocity state. The results indicate that gait speed highly correlated with stability against backward balance loss at slip onset. The low COM velocity of the slow group was not sufficiently compensated for by a more anteriorly positioned COM associated with a shorter step length at slip onset. At touchdown of the compensatory step, the speed-related differences in stability diminished, due to the continued advantage of anterior COM positioning from a short compensatory step retained by the slow group, coupled with an increase in COM velocity. Compensatory step length and relative COM position altered as a function of gait speed, indicating the motor program for gait regulation may play a role in modulating the compensatory step.
A two-step method for developing a control rod program for boiling water reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taner, M.S.; Levine, S.H.; Hsiao, M.Y.
1992-01-01
This paper reports on a two-step method that is established for the generation of a long-term control rod program for boiling water reactors (BWRs). The new method assumes a time-variant target power distribution in core depletion. In the new method, the BWR control rod programming is divided into two steps. In step 1, a sequence of optimal, exposure-dependent Haling power distribution profiles is generated, utilizing the spectral shift concept. In step 2, a set of exposure-dependent control rod patterns is developed by using the Haling profiles generated at step 1 as a target. The new method is implemented in amore » computer program named OCTOPUS. The optimization procedure of OCTOPUS is based on the method of approximation programming, in which the SIMULATE-E code is used to determine the nucleonics characteristics of the reactor core state. In a test in cycle length over a time-invariant, target Haling power distribution case because of a moderate application of spectral shift. No thermal limits of the core were violated. The gain in cycle length could be increased further by broadening the extent of the spetral shift.« less
Effects of wide step walking on swing phase hip muscle forces and spatio-temporal gait parameters.
Bajelan, Soheil; Nagano, Hanatsu; Sparrow, Tony; Begg, Rezaul K
2017-07-01
Human walking can be viewed essentially as a continuum of anterior balance loss followed by a step that re-stabilizes balance. To secure balance an extended base of support can be assistive but healthy young adults tend to walk with relatively narrower steps compared to vulnerable populations (e.g. older adults and patients). It was, therefore, hypothesized that wide step walking may enhance dynamic balance at the cost of disturbed optimum coupling of muscle functions, leading to additional muscle work and associated reduction of gait economy. Young healthy adults may select relatively narrow steps for a more efficient gait. The current study focused on the effects of wide step walking on hip abductor and adductor muscles and spatio-temporal gait parameters. To this end, lower body kinematic data and ground reaction forces were obtained using an Optotrak motion capture system and AMTI force plates, respectively, while AnyBody software was employed for muscle force simulation. A single step of four healthy young male adults was captured during preferred walking and wide step walking. Based on preferred walking data, two parallel lines were drawn on the walkway to indicate 50% larger step width and participants targeted the lines with their heels as they walked. In addition to step width that defined walking conditions, other spatio-temporal gait parameters including step length, double support time and single support time were obtained. Average hip muscle forces during swing were modeled. Results showed that in wide step walking step length increased, Gluteus Minimus muscles were more active while Gracilis and Adductor Longus revealed considerably reduced forces. In conclusion, greater use of abductors and loss of adductor forces were found in wide step walking. Further validation is needed in future studies involving older adults and other pathological populations.
Surface-bound phosphatase activity in living hyphae of ectomycorrhizal fungi of Nothofagus obliqua.
Alvarez, Maricel; Godoy, Roberto; Heyser, Wolfgang; Härtel, Steffen
2004-01-01
We determined the location and the activity of surface-bound phosphomonoesterase (SBP) of five ectomycorrhizal (EM) fungi of Nothofagus oblique. EM fungal mycelium of Paxillus involutus, Austropaxillus boletinoides, Descolea antartica, Cenococcum geophilum and Pisolithus tinctorius was grown in media with varying concentrations of dissolved phosphorus. SBP activity was detected at different pH values (3-7) under each growth regimen. SBP activity was assessed using a colorimetric method based on the hydrolysis of p-nitrophenyl phosphate (pNPP) to p-nitrophenol phosphate (pNP) + P. A new technique involving confocal laser-scanning microscopy (LSM) was used to locate and quantify SBP activity on the hyphal surface. EM fungi showed two fundamentally different patterns of SBP activity in relation to varying environmental conditions (P-concentrations and pH). In the cases of D. antartica, A. boletinoides and C. geophilum, changes in SBP activity were induced primarily by changes in the number of SBP-active centers on the hyphae. In the cases of P. tinctorius and P. involutus, the number of SBP-active centers per μm hyphal length changed much less than the intensity of the SBP-active centers on the hyphae. Our findings not only contribute to the discussion about the role of SBP-active centers in EM fungi but also introduce LSM as a valuable method for studying EM fungi.
El-Gohary, Mahmoud; Peterson, Daniel; Gera, Geetanjali; Horak, Fay B; Huisinga, Jessie M
2017-07-01
To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Cross-sectional study. University medical center balance disorder laboratory. Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
A Pilot Study of Gait Function in Farmworkers in Eastern North Carolina.
Nguyen, Ha T; Kritchevsky, Stephen B; Foxworth, Judy L; Quandt, Sara A; Summers, Phillip; Walker, Francis O; Arcury, Thomas A
2015-01-01
Farmworkers endure many job-related hazards, including fall-related work injuries. Gait analysis may be useful in identifying potential fallers. The goal of this pilot study was to explore differences in gait between farmworkers and non-farmworkers. The sample included 16 farmworkers and 24 non-farmworkers. Gait variables were collected using the portable GAITRite system, a 16-foot computerized walkway. Generalized linear regression models were used to examine group differences. All models were adjusted for two established confounders, age and body mass index. There were no significant differences in stride length, step length, double support time, and base of support; but farmworkers had greater irregularity of stride length (P = .01) and step length (P = .08). Farmworkers performed significantly worse on gait velocity (P = .003) and cadence (P < .001) relative to non-farmworkers. We found differences in gait function between farmworkers and non-farmworkers. These findings suggest that measuring gait with a portable walkway system is feasible and informative in farmworkers and may possibly be of use in assessing fall risk.
Directly Reconstructing Principal Components of Heterogeneous Particles from Cryo-EM Images
Tagare, Hemant D.; Kucukelbir, Alp; Sigworth, Fred J.; Wang, Hongwei; Rao, Murali
2015-01-01
Structural heterogeneity of particles can be investigated by their three-dimensional principal components. This paper addresses the question of whether, and with what algorithm, the three-dimensional principal components can be directly recovered from cryo-EM images. The first part of the paper extends the Fourier slice theorem to covariance functions showing that the three-dimensional covariance, and hence the principal components, of a heterogeneous particle can indeed be recovered from two-dimensional cryo-EM images. The second part of the paper proposes a practical algorithm for reconstructing the principal components directly from cryo-EM images without the intermediate step of calculating covariances. This algorithm is based on maximizing the (posterior) likelihood using the Expectation-Maximization algorithm. The last part of the paper applies this algorithm to simulated data and to two real cryo-EM data sets: a data set of the 70S ribosome with and without Elongation Factor-G (EF-G), and a data set of the inluenza virus RNA dependent RNA Polymerase (RdRP). The first principal component of the 70S ribosome data set reveals the expected conformational changes of the ribosome as the EF-G binds and unbinds. The first principal component of the RdRP data set reveals a conformational change in the two dimers of the RdRP. PMID:26049077
Loaiza, Vanessa M; Borovanska, Borislava M
2018-01-01
Much research has investigated the qualitative experience of retrieving events from episodic memory (EM). The present study investigated whether covert retrieval in WM increases the phenomenological characteristics that participants find memorable in EM using tasks that distract attention from the maintenance of memoranda (i.e., complex span; Experiment 1) relative to tasks that do not (i.e., short or long list lengths of simple span; Experiments 1 and 2). Participants rated the quality of the phonological, semantic, and temporal-contextual characteristics remembered during a delayed memory characteristics questionnaire (MCQ). Whereas an advantage of the complex over simple span items was observed for each characteristic (Experiment 1), no such difference was observed between short and long trials of simple span (Experiment 2). These results are consistent with the view that covert retrieval in WM promotes content-context bindings that are later accessible from EM for both objective performance and subjective details of the remembered information. Copyright © 2017 Elsevier Inc. All rights reserved.
Ouyang, Wenli; Cuddy, Monica M; Swanson, David B
2015-09-01
Prior to graduation, US medical students are required to complete clinical clerkship rotations, most commonly in the specialty areas of family medicine, internal medicine, obstetrics and gynecology (ob/gyn), pediatrics, psychiatry, and surgery. Within a school, the sequence in which students complete these clerkships varies. In addition, the length of these rotations varies, both within a school for different clerkships and between schools for the same clerkship. The present study investigated the effects of clerkship sequence and length on performance on the National Board of Medical Examiner's subject examination in internal medicine. The study sample included 16,091 students from 67 US Liaison Committee on Medical Education (LCME)-accredited medical schools who graduated in 2012 or 2013. Student-level measures included first-attempt internal medicine subject examination scores, first-attempt USMLE Step 1 scores, and five dichotomous variables capturing whether or not students completed rotations in family medicine, ob/gyn, pediatrics, psychiatry, and surgery prior to taking the internal medicine rotation. School-level measures included clerkship length and average Step 1 score. Multilevel models with students nested in schools were estimated with internal medicine subject examination scores as the dependent measure. Step 1 scores and the five dichotomous variables were treated as student-level predictors. Internal medicine clerkship length and average Step 1 score were used to predict school-to-school variation in average internal medicine subject examination scores. Completion of rotations in surgery, pediatrics and family medicine prior to taking the internal medicine examination significantly improved scores, with the largest benefit observed for surgery (coefficient = 1.58 points; p value < 0.01); completion of rotations in ob/gyn and psychiatry were unrelated to internal medicine subject examination performance. At the school level, longer internal medicine clerkships were associated with higher scores on the internal medicine examination (coefficient = 0.23 points/week; p value < 0.01). The order in which students complete clinical clerkships and the length of the internal medicine clerkship are associated with their internal medicine subject examination scores. Findings may have implications for curriculum re-design.
Investigation of a slot nanoantenna in optical frequency range
NASA Astrophysics Data System (ADS)
Dinesh kumar, V.; Asakawa, Kiyoshi
2009-11-01
Following the analogy of radio frequency slot antenna and its complementary dipole, we propose the implementation of a slot nanoantenna (SNA) in the optical frequency range. Using finite-difference time-domain (FDTD) method, we investigate the electromagnetic (EM) properties of a SNA formed in a thin gold film and compare the results with the properties of a gold dipole nanoantenna (DNA) of the same dimension as the slot. It is found that the response of the SNA is very similar to the DNA, like their counterparts in the radio frequency (RF) range. The SNA can enhance the near field intensity of incident field which strongly depends on its feedgap dimension. The resonance of the SNA is influenced by its slot length; for the increasing slot length, resonant frequency decreases whereas the sharpness of resonance increases. Besides, the resonance of the SNA is found sensitive to the thickness of metal film, when the latter is smaller than the skin depth. The effect of polarization of incident field on the EM response of the SNA was examined; the field enhancement is optimum when polarization is parallel to the feedgap. Finally, we calculate the radiation patterns of the DNA and SNA and compare them with those of the RF dipole antenna. The radiation pattern of the SNA is found to be independent of its slot length when excited at resonant frequency. To the best of our knowledge, this is the first study on a slot antenna in the optical frequency.
Fast and secure encryption-decryption method based on chaotic dynamics
Protopopescu, Vladimir A.; Santoro, Robert T.; Tolliver, Johnny S.
1995-01-01
A method and system for the secure encryption of information. The method comprises the steps of dividing a message of length L into its character components; generating m chaotic iterates from m independent chaotic maps; producing an "initial" value based upon the m chaotic iterates; transforming the "initial" value to create a pseudo-random integer; repeating the steps of generating, producing and transforming until a pseudo-random integer sequence of length L is created; and encrypting the message as ciphertext based upon the pseudo random integer sequence. A system for accomplishing the invention is also provided.
NASA Technical Reports Server (NTRS)
Barone, Michael R. (Inventor); Murdoch, Karen (Inventor); Scull, Timothy D. (Inventor); Fort, James H. (Inventor)
2009-01-01
A rotary phase separator system generally includes a step-shaped rotary drum separator (RDS) and a motor assembly. The aspect ratio of the stepped drum minimizes power for both the accumulating and pumping functions. The accumulator section of the RDS has a relatively small diameter to minimize power losses within an axial length to define significant volume for accumulation. The pumping section of the RDS has a larger diameter to increase pumping head but has a shorter axial length to minimize power losses. The motor assembly drives the RDS at a low speed for separating and accumulating and a higher speed for pumping.
Nonequilibrium transport in superconducting filaments
NASA Technical Reports Server (NTRS)
Arutyunov, K. YU.; Danilova, N. P.; Nikolaeva, A. A.
1995-01-01
The step-like current-voltage characteristics of highly homogeneous single-crystalline tin and indium thin filaments has been measured. The length of the samples L approximately 1 cm was much greater than the nonequilibrium quasiparticle relaxation length Lambda. It was found that the activation of a successive i-th voltage step occurs at current significantly greater than the one derived with the assumption that the phase slip centers are weakly interacting on a scale L much greater than Lambda. The observation of 'subharmonic' fine structure on the voltage-current characteristics of tin filaments confirms the hypothesis of the long-range phase slip centers interaction.
Stabilization of a three-dimensional limit cycle walking model through step-to-step ankle control.
Kim, Myunghee; Collins, Steven H
2013-06-01
Unilateral, below-knee amputation is associated with an increased risk of falls, which may be partially related to a loss of active ankle control. If ankle control can contribute significantly to maintaining balance, even in the presence of active foot placement, this might provide an opportunity to improve balance using robotic ankle-foot prostheses. We investigated ankle- and hip-based walking stabilization methods in a three-dimensional model of human gait that included ankle plantarflexion, ankle inversion-eversion, hip flexion-extension, and hip ad/abduction. We generated discrete feedback control laws (linear quadratic regulators) that altered nominal actuation parameters once per step. We used ankle push-off, lateral ankle stiffness and damping, fore-aft foot placement, lateral foot placement, or all of these as control inputs. We modeled environmental disturbances as random, bounded, unexpected changes in floor height, and defined balance performance as the maximum allowable disturbance value for which the model walked 500 steps without falling. Nominal walking motions were unstable, but were stabilized by all of the step-to-step control laws we tested. Surprisingly, step-by-step modulation of ankle push-off alone led to better balance performance (3.2% leg length) than lateral foot placement (1.2% leg length) for these control laws. These results suggest that appropriate control of robotic ankle-foot prosthesis push-off could make balancing during walking easier for individuals with amputation.
A novel trapezoid fin pattern applicable for air-cooled heat sink
NASA Astrophysics Data System (ADS)
Chen, Chien-Hung; Wang, Chi-Chuan
2015-11-01
The present study proposed a novel step or trapezoid surface design applicable to air-cooled heat sink under cross flow condition. A total of five heat sinks were made and tested, and the corresponding fin patterns are (a) plate fin; (b) step fin (step 1/3, 3 steps); (c) 2-step fin (step 1/2, 2 steps); (d) trapezoid fin (trap 1/3, cutting 1/3 length from the rear end) and (e) trapezoid fin (trap 1/2, cutting 1/2 length from the rear end). The design is based on the heat transfer augmentation via (1) longer perimeter of entrance region and (2) larger effective temperature difference at the rear part of the heat sink. From the test results, it is found that either step or trapezoid design can provide a higher heat transfer conductance and a lower pressure drop at a specified frontal velocity. The effective conductance of trap 1/3 design exceeds that of plate surface by approximately 38 % at a frontal velocity of 5 m s-1 while retains a lower pressure drop of 20 % with its surface area being reduced by 20.6 %. For comparisons exploiting the overall thermal resistance versus pumping power, the resultant thermal resistance of the proposed trapezoid design 1/3, still reveals a 10 % lower thermal resistance than the plate fin surface at a specified pumping power.
Age-related changes in the center of mass velocity control during walking.
Chong, Raymond K Y; Chastan, Nathalie; Welter, Marie-Laure; Do, Manh-Cuong
2009-07-10
During walking, the body center of mass oscillates along the vertical plane. Its displacement is highest at mid-swing and lowest at terminal swing during the transition to double support. Its vertical velocity (CoMv) has been observed to increase as the center of mass falls between mid- and late swing but is reduced just before double support. This suggests that braking of the center of mass is achieved with active neural control. We tested whether this active control deteriorates with aging (Experiment 1) and during a concurrent cognitive task (Experiment 2). At short steps of <0.4m, CoMv control was low and similar among all age groups. All groups braked the CoMv at longer steps of >0.4m but older subjects did so to a lesser extent. During the cognitive task, young subjects increased CoMv control (i.e. increase in CoMv braking) while maintaining step length and walking speed. Older subjects on the other hand, did not increase CoMv control but rather maintain it by reducing both step length and walking speed. These results suggest that active braking of the CoM during the transition to double support predominates in steps >0.4m. It could be a manifestation of the balance control system, since the braking occurs at late stance where body weight is being shifted to the contralateral side. The active braking mechanism also appears to require some attentional resource. In aging, reducing step length and speed are strategic to maintaining effective center of mass control during the transition to double support. However, the lesser degree of control in older adults indicates a true age-related deficit.
Naimi, Mohamed; Znari, Mohammed; Lovich, Jeffrey E.; Feddadi, Youssef; Baamrane, Moulay Abdeljalil Ait
2012-01-01
We examined the relationships of clutch size (CS) and egg size to female body size (straight-line carapace length, CL) in a population of the turtle Mauremys leprosa from a polluted segment of oued (river) Tensift in arid west-central Morocco. Twenty-eight adult females were collected in May–July, 2009 and all were gravid. Each was weighed, measured, humanely euthanized and then dissected. Oviductal shelled eggs were removed, weighed (egg mass, EM) and measured for length (EL) and width (EW). Clutch mass (CM) was the sum of EM for a clutch. Pelvic aperture width (PAW) was measured at the widest point between the ilia bones through which eggs must pass at oviposition. The smallest gravid female had a CL of 124.0 mm. Mean CS was relatively large (9.7±2.0 eggs, range: 3–13) and may reflect high productivity associated with polluted (eutrophic) waters. Regression analyses were conducted using log-transformed data. CM increased isometrically with maternal body size. CS, EW and EM were all significantly hypoallometric in their relationship with CL. EL did not change significantly with increases in CL. EW increased at a hypoallometric rate with increasing CL but was unconstrained by PAW since the widest egg was smaller than the narrowest PAW measurement when excluding the three smallest females. Smaller females may have EW constrained by PAW. As females increase in size they increase both clutch size and egg width in contradiction to predictions of optimal egg size theory.
Finley, James M.; Long, Andrew; Bastian, Amy J.; Torres-Oviedo, Gelsy
2014-01-01
Background Step length asymmetry (SLA) is a common hallmark of gait post-stroke. Though conventionally viewed as a spatial deficit, SLA can result from differences in where the feet are placed relative to the body (spatial strategy), the timing between foot-strikes (step time strategy), or the velocity of the body relative to the feet (step velocity strategy). Objective The goal of this study was to characterize the relative contributions of each of these strategies to SLA. Methods We developed an analytical model that parses SLA into independent step position, step time, and step velocity contributions. This model was validated by reproducing SLA values for twenty-five healthy participants when their natural symmetric gait was perturbed on a split-belt treadmill moving at either a 2:1 or 3:1 belt-speed ratio. We then applied the validated model to quantify step position, step time, and step velocity contributions to SLA in fifteen stroke survivors while walking at their self-selected speed. Results SLA was predicted precisely by summing the derived contributions, regardless of the belt-speed ratio. Although the contributions to SLA varied considerably across our sample of stroke survivors, the step position contribution tended to oppose the other two – possibly as an attempt to minimize the overall SLA. Conclusions Our results suggest that changes in where the feet are placed or changes in interlimb timing could be used as compensatory strategies to reduce overall SLA in stroke survivors. These results may allow clinicians and researchers to identify patient-specific gait abnormalities and personalize their therapeutic approaches accordingly. PMID:25589580
Effective robotic assistive pattern of treadmill training for spinal cord injury in a rat model
Zhao, Bo-Lun; Li, Wen-Tao; Zhou, Xiao-Hua; Wu, Su-Qian; Cao, Hong-Shi; Bao, Zhu-Ren; An, Li-Bin
2018-01-01
The purpose of the present study was to establish an effective robotic assistive stepping pattern of body-weight-supported treadmill training based on a rat spinal cord injury (SCI) model and assess the effect by comparing this with another frequently used assistive stepping pattern. The recorded stepping patterns of both hind limbs of trained intact rats were edited to establish a 30-sec playback normal rat stepping pattern (NRSP). Step features (step length, step height, step number and swing duration), BBB scores, latencies, and amplitudes of the transcranial electrical motor-evoked potentials (tceMEPs) and neurofilament 200 (NF200) expression in the spinal cord lesion area during and after 3 weeks of body-weight-supported treadmill training (BWSTT) were compared in rats with spinal contusion receiving NRSP assistance (NRSPA) and those that received manual assistance (MA). Hind limb stepping performance among rats receiving NRSPA during BWSTT was greater than that among rats receiving MA in terms of longer step length, taller step height, and longer swing duration. Furthermore a higher BBB score was also indicated. The rats in the NRSPA group achieved superior results in the tceMEPs assessment and greater NF200 expression in the spinal cord lesion area compared with the rats in the MA group. These findings suggest NRSPA was an effective assistive pattern of treadmill training compared with MA based on the rat SCI model and this approach could be used as a new platform for animal experiments for better understanding the mechanisms of SCI rehabilitation. PMID:29545846
NASA Astrophysics Data System (ADS)
Patra, Swayamshree; Chowdhury, Debashish
2018-01-01
We introduce a multispecies exclusion model where length-conserving probabilistic fusion and fission of the hard rods are allowed. Although all rods enter the system with the same initial length ℓ =1 , their length can keep changing, because of fusion and fission, as they move in a step-by-step manner towards the exit. Two neighboring hard rods of lengths ℓ1 and ℓ2 can fuse into a single rod of longer length ℓ =ℓ1+ℓ2 provided ℓ ≤N . Similarly, length-conserving fission of a rod of length ℓ'≤N results in two shorter daughter rods. Based on the extremum current hypothesis, we plot the phase diagram of the model under open boundary conditions utilizing the results derived for the same model under periodic boundary condition using mean-field approximation. The density profile and the flux profile of rods are in excellent agreement with computer simulations. Although the fusion and fission of the rods are motivated by similar phenomena observed in intraflagellar transport (IFT) in eukaryotic flagella, this exclusion model is too simple to account for the quantitative experimental data for any specific organism. Nevertheless, the concepts of "flux profile" and "transition zone" that emerge from the interplay of fusion and fission in this model are likely to have important implications for IFT and for other similar transport phenomena in long cell protrusions.
By counteracting gravity, triceps surae sets both kinematics and kinetics of gait
Honeine, Jean‐Louis; Schieppati, Marco; Gagey, Oliver; Do, Manh‐Cuong
2014-01-01
Abstract In the single‐stance phase of gait, gravity acting on the center of mass (CoM) causes a disequilibrium torque, which generates propulsive force. Triceps surae activity resists gravity by restraining forward tibial rotation thereby tuning CoM momentum. We hypothesized that time and amplitude modulation of triceps surae activity determines the kinematics (step length and cadence) and kinetics of gait. Nineteen young subjects participated in two experiments. In the gait initiation (GI) protocol, subjects deliberately initiated walking at different velocities for the same step length. In the balance‐recovery (BR) protocol, subjects executed steps of different length after being unexpectedly released from an inclined posture. Ground reaction force was recorded by a large force platform and electromyography of soleus, gastrocnemius medialis and lateralis, and tibialis anterior muscles was collected by wireless surface electrodes. In both protocols, the duration of triceps activity was highly correlated with single‐stance duration (GI, R2 = 0.68; BR, R2 = 0.91). In turn, step length was highly correlated with single‐stance duration (BR, R2 = 0.70). Control of CoM momentum was obtained by decelerating the CoM fall via modulation of amplitude of triceps activity. By modulation of triceps activity, the central nervous system (CNS) varied the position of CoM with respect to the center of pressure (CoP). The CoM‐CoP gap in the sagittal plane was determinant for setting the disequilibrium torque and thus walking velocity. Thus, by controlling the gap, CNS‐modified walking velocity (GI, R2 = 0.86; BR, R2 = 0.92). This study is the first to highlight that by merely counteracting gravity, triceps activity sets the kinematics and kinetics of gait. It also provides evidence that the surge in triceps activity during fast walking is due to the increased requirement of braking the fall of CoM in late stance in order to perform a smoother step‐to‐step transition. PMID:24744898
Visualization of Circuit Card EM Fields.
1998-03-31
0.010 - Photoimageable (Min.): 0.005 «Located at 7845 -J Airpark Road; Gaithersburg, Maryland 20879. 301-977-0303, http://www.capitalelectro.com...rlabelC«’); tit-. Ch .3SO; print -dep« fig_conn.h36.ep«; fignre; X differential node rel.diff_vec-0; h_vec«0.6:0.2:6.0; len_h«length(h_ve_); for i
USDA-ARS?s Scientific Manuscript database
The length of cotton fiber is an important agronomic trait characteristic that directly affects the quality of yarn and fabric. Cotton fiber mutants have been useful tools to study the molecular processes of fiber development. In this work we describe a chemically-induced short fiber mutant Ligon-li...
The EMS system and disaster planning: some observations.
Holloway, R D; Steliga, J F; Ryan, C T
1978-02-01
Disaster planning, one of the 15 essential components of the Emergency Medical Service System Act of 1973, should be the culmination of the establishment of other components. Regions have gone to varying lengths to describe disaster plans but how realistic the plans are is questionable. New York has planned for multiple casualty incidents (MCI) to care for victims of fires, explosions, structural collapses and major transportation incidents. The irrational emotional response in mass disasters conflicts with the rational disaster plans written by health planners. Drills of disaster plans are not realistic. One solution is to designate the next serious incident, such as a fire or traffic accident, a major MCI. The ability to handle an MCI is probably the best measure of an EMS system's effectiveness.
Frequency-velocity mismatch: a fundamental abnormality in parkinsonian gait.
Cho, Catherine; Kunin, Mikhail; Kudo, Koji; Osaki, Yasuhiro; Olanow, C Warren; Cohen, Bernard; Raphan, Theodore
2010-03-01
Gait dysfunction and falling are major sources of disability for patients with advanced Parkinson's disease (PD). It is presently thought that the fundamental defect is an inability to generate normal stride length. Our data suggest, however, that the basic problem in PD gait is an impaired ability to match step frequency to walking velocity. In this study, foot movements of PD and normal subjects were monitored with an OPTOTRAK motion-detection system while they walked on a treadmill at different velocities. PD subjects were also paced with auditory stimuli at different frequencies. PD gait was characterized by step frequencies that were faster and stride lengths that were shorter than those of normal controls. At low walking velocities, PD stepping had a reduced or absent terminal toe lift, which truncated swing phases, producing shortened steps. Auditory pacing was not able to normalize step frequency at these lower velocities. Peak forward toe velocities increased with walking velocity and PD subjects could initiate appropriate foot dynamics during initial phases of the swing. They could not control the foot appropriately in terminal phases, however. Increased treadmill velocity, which matched the natural PD step frequency, generated a second toe lift, normalizing step size. Levodopa increased the bandwidth of step frequencies, but was not as effective as increases in walking velocity in normalizing gait. We postulate that the inability to control step frequency and adjust swing phase dynamics to slower walking velocities are major causes for the gait impairment in PD.
Frequency-Velocity Mismatch: A Fundamental Abnormality in Parkinsonian Gait
Kunin, Mikhail; Kudo, Koji; Osaki, Yasuhiro; Olanow, C. Warren; Cohen, Bernard; Raphan, Theodore
2010-01-01
Gait dysfunction and falling are major sources of disability for patients with advanced Parkinson's disease (PD). It is presently thought that the fundamental defect is an inability to generate normal stride length. Our data suggest, however, that the basic problem in PD gait is an impaired ability to match step frequency to walking velocity. In this study, foot movements of PD and normal subjects were monitored with an OPTOTRAK motion-detection system while they walked on a treadmill at different velocities. PD subjects were also paced with auditory stimuli at different frequencies. PD gait was characterized by step frequencies that were faster and stride lengths that were shorter than those of normal controls. At low walking velocities, PD stepping had a reduced or absent terminal toe lift, which truncated swing phases, producing shortened steps. Auditory pacing was not able to normalize step frequency at these lower velocities. Peak forward toe velocities increased with walking velocity and PD subjects could initiate appropriate foot dynamics during initial phases of the swing. They could not control the foot appropriately in terminal phases, however. Increased treadmill velocity, which matched the natural PD step frequency, generated a second toe lift, normalizing step size. Levodopa increased the bandwidth of step frequencies, but was not as effective as increases in walking velocity in normalizing gait. We postulate that the inability to control step frequency and adjust swing phase dynamics to slower walking velocities are major causes for the gait impairment in PD. PMID:20042701
Changes in step-width during dual-task walking predicts falls.
Nordin, E; Moe-Nilssen, R; Ramnemark, A; Lundin-Olsson, L
2010-05-01
The aim was to evaluate whether gait pattern changes between single- and dual-task conditions were associated with risk of falling in older people. Dual-task cost (DTC) of 230 community living, physically independent people, 75 years or older, was determined with an electronic walkway. Participants were followed up each month for 1 year to record falls. Mean and variability measures of gait characteristics for 5 dual-task conditions were compared to single-task walking for each participant. Almost half (48%) of the participants fell at least once during follow-up. Risk of falling increased in individuals where DTC for performing a subtraction task demonstrated change in mean step-width compared to single-task walking. Risk of falling decreased in individuals where DTC for carrying a cup and saucer demonstrated change compared to single-task walking in mean step-width, mean step-time, and step-length variability. Degree of change in gait characteristics related to a change in risk of falling differed between measures. Prognostic guidance for fall risk was found for the above DTCs in mean step-width with a negative likelihood ratio of 0.5 and a positive likelihood ratio of 2.3, respectively. Findings suggest that changes in step-width, step-time, and step-length with dual tasking may be related to future risk of falling. Depending on the nature of the second task, DTC may indicate either an increased risk of falling, or a protective strategy to avoid falling. Copyright 2010. Published by Elsevier B.V.
Gait dynamics in Pisa syndrome and Camptocormia: The role of stride length and hip kinematics.
Tramonti, C; Di Martino, S; Unti, E; Frosini, D; Bonuccelli, U; Rossi, B; Ceravolo, R; Chisari, C
2017-09-01
This is an observational cross-sectional study evaluating gait dynamics in patients with Parkinson's Disease (PD) and severe postural deformities, PD without axial deviations and healthy subjects. Ten PS individuals with Pisa syndrome (PS) and nine subjects with Camptocormia (CC) performed 3-D Gait Analysis and were evaluated with walking and balance scales. Correlations with clinical and functional scales were investigated. Spatio-temporal and kinematic data were compared to ten PD subjects without postural deformities (PP) and ten healthy matched individuals (CG). Data obtained showed decreased walking velocity, stride and step length in PP, PS and CC groups compared to controls. The correlation analysis showed that stride and step length were associated with reduced functional abilities and disease severity in PS and CC groups. Kinematic data revealed marked reduction in range of movements (ROMs) at all lower-extremity joints in PS group. While, in CC group the main differences were pronounced in hip and knee joints. PS and CC groups presented a more pronounced reduction in hip articular excursion compared to PP subjects, revealing an increased hip flexion pattern during gait cycle. Moreover, the increased hip and knee flexion pattern adversely affected functional performance during walking tests. Results obtained provide evidence that step length, along with stride length, can be proposed as simple and clear indicators of disease severity and reduced functional abilities. The reduction of ROMs at hip joint represented an important mechanism contributing to decreased walking velocity, balance impairment and reduced gait performance in PD patients with postural deformities. Copyright © 2017 Elsevier B.V. All rights reserved.
The semantic distance task: Quantifying semantic distance with semantic network path length.
Kenett, Yoed N; Levi, Effi; Anaki, David; Faust, Miriam
2017-09-01
Semantic distance is a determining factor in cognitive processes, such as semantic priming, operating upon semantic memory. The main computational approach to compute semantic distance is through latent semantic analysis (LSA). However, objections have been raised against this approach, mainly in its failure at predicting semantic priming. We propose a novel approach to computing semantic distance, based on network science methodology. Path length in a semantic network represents the amount of steps needed to traverse from 1 word in the network to the other. We examine whether path length can be used as a measure of semantic distance, by investigating how path length affect performance in a semantic relatedness judgment task and recall from memory. Our results show a differential effect on performance: Up to 4 steps separating between word-pairs, participants exhibit an increase in reaction time (RT) and decrease in the percentage of word-pairs judged as related. From 4 steps onward, participants exhibit a significant decrease in RT and the word-pairs are dominantly judged as unrelated. Furthermore, we show that as path length between word-pairs increases, success in free- and cued-recall decreases. Finally, we demonstrate how our measure outperforms computational methods measuring semantic distance (LSA and positive pointwise mutual information) in predicting participants RT and subjective judgments of semantic strength. Thus, we provide a computational alternative to computing semantic distance. Furthermore, this approach addresses key issues in cognitive theory, namely the breadth of the spreading activation process and the effect of semantic distance on memory retrieval. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Bouillon, Lucinda E; Wilhelm, Jacqueline; Eisel, Patricia; Wiesner, Jessica; Rachow, Megan; Hatteberg, Lindsay
2012-12-01
Researchers have observed differences in muscle activity patterns between males and females during functional exercises. The research methods employed have used various step heights and lunge distances to assess functional exercise making gender comparisons difficult. The purpose of this study was to examine core and lower extremity muscle activity between genders during single-limb exercises using adjusted distances and step heights based on a percentage of the participant's height. Twenty men and 20 women who were recreationally active and healthy participated in the study. Two-dimensional video and surface electromyography (SEMG) were used to assess performance during three exercise maneuvers (step down, forward lunge, and side-step lunge). Eight muscles were assessed using SEMG (rectus abdominus, external oblique, erector spinae, rectus femoris, tensor fascia latae, gluteus medius, gluteus maximus, biceps femoris). Maximal voluntary isometric contractions (MVIC) were used for each muscle and expressed as %MVIC to normalize SEMG to account for body mass differences. Exercises were randomized and distances were normalized to the participant's lower limb length. Descriptive statistics, mixed-model ANOVA, and ICCs with 95% confidence intervals were calculated. Males were taller, heavier, and had longer leg length when compared to the females. No differences in %MVIC activity were found between genders by task across the eight muscles. For both males and females, the step down task resulted in higher %MVIC for gluteus maximus compared to lunge, (p=0.002). Step down exercise produced higher %MVIC for gluteus medius than lunge (p=0.002) and side step (p=0.006). ICC(3,3) ranged from moderate to high (0.74 to 0.97) for the three tasks. Muscle activation among the eight muscles was similar between females and males during the lunge, side-step, and step down tasks, with distances adjusted to leg length. Both males and females elicited higher muscle activity for gluteus maximus and gluteus medius as compared to the trunk, hip flexors, or hamstring muscles. However these values were well below the recruitment levels necessary for strengthening in both genders. 4.
Wilhelm, Jacqueline; Eisel, Patricia; Wiesner, Jessica; Rachow, Megan; Hatteberg, Lindsay
2012-01-01
Purpose/Background: Researchers have observed differences in muscle activity patterns between males and females during functional exercises. The research methods employed have used various step heights and lunge distances to assess functional exercise making gender comparisons difficult. The purpose of this study was to examine core and lower extremity muscle activity between genders during single‐limb exercises using adjusted distances and step heights based on a percentage of the participant's height. Methods: Twenty men and 20 women who were recreationally active and healthy participated in the study. Two‐dimensional video and surface electromyography (SEMG) were used to assess performance during three exercise maneuvers (step down, forward lunge, and side‐step lunge). Eight muscles were assessed using SEMG (rectus abdominus, external oblique, erector spinae, rectus femoris, tensor fascia latae, gluteus medius, gluteus maximus, biceps femoris). Maximal voluntary isometric contractions (MVIC) were used for each muscle and expressed as %MVIC to normalize SEMG to account for body mass differences. Exercises were randomized and distances were normalized to the participant's lower limb length. Descriptive statistics, mixed‐model ANOVA, and ICCs with 95% confidence intervals were calculated. Results: Males were taller, heavier, and had longer leg length when compared to the females. No differences in %MVIC activity were found between genders by task across the eight muscles. For both males and females, the step down task resulted in higher %MVIC for gluteus maximus compared to lunge, (p=0.002). Step down exercise produced higher %MVIC for gluteus medius than lunge (p=0.002) and side step (p=0.006). ICC3,3 ranged from moderate to high (0.74 to 0.97) for the three tasks. Conclusions: Muscle activation among the eight muscles was similar between females and males during the lunge, side‐step, and step down tasks, with distances adjusted to leg length. Both males and females elicited higher muscle activity for gluteus maximus and gluteus medius as compared to the trunk, hip flexors, or hamstring muscles. However these values were well below the recruitment levels necessary for strengthening in both genders. Level of evidence: 4 PMID:23316423
NASA Technical Reports Server (NTRS)
Jovic, Srba; Kutler, Paul F. (Technical Monitor)
1994-01-01
Experimental results for a two-dimensional separated turbulent boundary layer behind a backward facing step for five different Reynolds numbers are reported. Results are presented in the form of tables, graphs and a floppy disk for an easy access of the data. Reynolds number based on the step height was varied by changing the reference velocity upstream of the step, U(sub o), and the step height, h. Hot-wire measurement techniques were used to measure three Reynolds stresses and four triple-velocity correlations. In addition, surface pressure and skin friction coefficients were measured. All hot-wire measurements were acquired in a measuring domain which excluded recirculating flow region due to the directional insensitivity of hot-wires. The downstream extent of the domain from the step was 51 h for the largest and I 14h for the smallest step height. This significant downstream length permitted extensive study of the flow recovery. Prediction of perturbed flows and their recovery is particularly attractive for popular turbulence models since variations of turbulence length and time scales and flow interactions in different regions are generally inadequately predicted. The data indicate that the flow in the free shear layer region behaves like the plane mixing layer up to about 2/3 of the mean reattachment length when the flow interaction with the wall commences the flow recovery to that of an ordinary turbulent boundary layer structure. These changes of the flow do not occur abruptly with the change of boundary conditions. A reattachment region represents a transitional region where the flow undergoes the most dramatic adjustments to the new boundary conditions. Large eddies, created in the upstream free-shear layer region, are being torn, recirculated, reentrained back into the main stream interacting with the incoming flow structure. It is foreseeable that it is quite difficult to describe the physics of this region in a rational and quantitative manner other than statistical. Downstream of the reattachment point the flow recovers at different rates near the wall, in the newly developing internal boundary layer, and in the outer part of the flow. It appears that Reynolds stresses do not fully recover up to the longest recovery length of 114 h.
NASA Astrophysics Data System (ADS)
Proost, Joris; Maex, Karen; Delacy, Luc
2000-01-01
We have discussed electromigration (EM)-induced drift in polycrystalline damascene versus reactive ion etched (RIE) Al(Cu) in part I. For polycrystalline Al(Cu), mass transport is well documented to occur through sequential stages : an incubation period (attributed to Cu depletion beyond a critical length) followed by the Al drift stage. In this work, the drift behavior of bamboo RIE and damascene Al(Cu) is analyzed. Using Blech-type test structures, mass transport in RIE lines was shown to proceed both by lattice and interfacial diffusion. The dominating mechanism depends on the Cu distribution in the line, as was evidenced by comparing as-patterned (lattice EM) and RTP-annealed (interface EM) samples. The interfacial EM only occurs at metallic interfaces. In that case, Cu alloying was observed to retard Al interfacial mass transport, giving rise to an incubation time. Although the activation energy for the incubation time was found similar to the one controlling Al lattice drift, for which no incubation time was observed, lattice EM is preferred over interfacial EM because it is insensitive to enhancing geometrical effects upon scaling. When comparing interfacial electromigration in RIE with bamboo damascene Al(Cu), with the incubation time rate controlling for both, the higher EM threshold observed for damascene was shown to be insufficient to compensate for its significantly increased Cu depletion rate, contrary to the case of polycrystalline Al(Cu) interconnects. Two factors were demonstrated to contribute. First, there are more metallic interfaces, intrinsically related to the use of wetting or barrier layers in recessed features. Second, specific to this study, the additional formation of TiAl3 at the trench sidewalls further enhanced the Cu depletion rate, and reduced the rate-controlling incubation time. A separate drift study on RIE via-type test structures indicated that it is very difficult to suppress interfacial mass transport in favor of lattice EM upon TiAl3 formation.
Case-Deletion Diagnostics for Nonlinear Structural Equation Models
ERIC Educational Resources Information Center
Lee, Sik-Yum; Lu, Bin
2003-01-01
In this article, a case-deletion procedure is proposed to detect influential observations in a nonlinear structural equation model. The key idea is to develop the diagnostic measures based on the conditional expectation of the complete-data log-likelihood function in the EM algorithm. An one-step pseudo approximation is proposed to reduce the…
Machado, Aline Dos Santos; Pires-Neto, Ruy Camargo; Carvalho, Maurício Tatsch Ximenes; Soares, Janice Cristina; Cardoso, Dannuey Machado; Albuquerque, Isabella Martins de
2017-01-01
To evaluate the effects that passive cycling exercise, in combination with conventional physical therapy, have on peripheral muscle strength, duration of mechanical ventilation, and length of hospital stay in critically ill patients admitted to the ICU of a tertiary care university hospital. This was a randomized clinical trial involving 38 patients (≥ 18 years of age) on mechanical ventilation who were randomly divided into two groups: control (n = 16), receiving conventional physical therapy; and intervention (n = 22), receiving conventional physical therapy and engaging in passive cycling exercise five days per week. The mean age of the patients was 46.42 ± 16.25 years, and 23 were male. The outcomes studied were peripheral muscle strength, as measured by the Medical Research Council scale, duration of mechanical ventilation, and length of hospital stay. There was a significant increase in peripheral muscle strength (baseline vs. final) in both groups (control: 40.81 ± 7.68 vs. 45.00 ± 6.89; and intervention: 38.73 ± 11.11 vs. 47.18 ± 8.75; p < 0.001 for both). However, the range of increase in strength was higher in the intervention group than in the control group (8.45 ± 5.20 vs. 4.18 ± 2.63; p = 0.005). There were no significant differences between the groups in terms of duration of mechanical ventilation or length of hospital stay. The results suggest that the performance of continuous passive mobilization on a cyclical basis helps to recover peripheral muscle strength in ICU patients. (ClinicalTrials.gov Identifier: NCT01769846 [http://www.clinicaltrials.gov/]). Avaliar os efeitos da realização de exercícios passivos com um cicloergômetro, associada à fisioterapia convencional, na força muscular periférica, no tempo de ventilação mecânica e no tempo de internação hospitalar em pacientes críticos internados em UTI de um hospital universitário terciário. Ensaio clínico randomizado envolvendo 38 pacientes (idade > 18 anos) em ventilação mecânica e divididos aleatoriamente em grupo controle (n = 16), que realizou fisioterapia convencional, e grupo intervenção (n = 22) submetidos a fisioterapia convencional e exercícios passivos em cicloergômetro cinco vezes por semana. A média de idade dos pacientes foi de 46,42 ± 16,25 anos, e 23 eram homens. Os desfechos analisados foram força muscular periférica, mensurada pela escala Medical Research Council, tempo de ventilação mecânica e tempo de internação hospitalar. Houve um aumento significativo da força muscular periférica (basal vs. final) tanto no grupo controle (40,81 ± 7,68 vs. 45,00 ± 6,89; p < 0,001) quanto no grupo intervenção (38,73 ± 11,11 vs. 47,18 ± 8,75; p < 0,001). Entretanto, a variação do aumento da força foi maior no grupo intervenção que no controle (8,45 ± 5,20 vs. 4,18 ± 2,63; p = 0,005). Não foram observadas diferenças significativas entre os grupos quanto ao tempo de ventilação mecânica e tempo de internação hospitalar. Os resultados sugerem que a realização de mobilização passiva contínua de forma cíclica auxilia na recuperação da força muscular periférica de pacientes internados em UTI. (ClinicalTrials.gov Identifier: NCT01769846 [http://www.clinicaltrials.gov/]).
Rochester, Lynn; Baker, Katherine; Nieuwboer, Alice; Burn, David
2011-02-15
Independence of certain gait characteristics from dopamine replacement therapies highlights its complex pathophysiology in Parkinson's disease (PD). We explored the effect of two different cue strategies on gait characteristics in relation to their response to dopaminergic medications. Fifty people with PD (age 69.22 ± 6.6 years) were studied. Participants walked with and without cues presented in a randomized order. Cue strategies were: (1) internal cue (attention to increase step length) and (2) external cue (auditory cue with instruction to take large step to the beat). Testing was carried out two times at home (on and off medication). Gait was measured using a Stride Analyzer (B&L Engineering). Gait outcomes were walking speed, stride length, step frequency, and coefficient of variation (CV) of stride time and double limb support duration (DLS). Walking speed, stride length, and stride time CV improved on dopaminergic medications, whereas step frequency and DLS CV did not. Internal and external cues increased stride time and walking speed (on and off dopaminergic medications). Only the external cue significantly improved stride time CV and DLS CV, whereas the internal cue had no effect (on and off dopaminergic medications). Internal and external cues selectively modify gait characteristics in relation to the type of gait disturbance and its dopa-responsiveness. Although internal (attention) and external cues target dopaminergic gait dysfunction (stride length), only external cues target stride to stride fluctuations in gait. Despite an overlap with dopaminergic pathways, external cues may effectively address nondopaminergic gait dysfunction and potentially increase mobility and reduce gait instability and falls. Copyright © 2010 Movement Disorder Society.
Dambreville, Charline; Labarre, Audrey; Thibaudier, Yann; Hurteau, Marie-France
2015-01-01
When speed changes during locomotion, both temporal and spatial parameters of the pattern must adjust. Moreover, at slow speeds the step-to-step pattern becomes increasingly variable. The objectives of the present study were to assess if the spinal locomotor network adjusts both temporal and spatial parameters from slow to moderate stepping speeds and to determine if it contributes to step-to-step variability in left-right symmetry observed at slow speeds. To determine the role of the spinal locomotor network, the spinal cord of 6 adult cats was transected (spinalized) at low thoracic levels and the cats were trained to recover hindlimb locomotion. Cats were implanted with electrodes to chronically record electromyography (EMG) in several hindlimb muscles. Experiments began once a stable hindlimb locomotor pattern emerged. During experiments, EMG and bilateral video recordings were made during treadmill locomotion from 0.1 to 0.4 m/s in 0.05 m/s increments. Cycle and stance durations significantly decreased with increasing speed, whereas swing duration remained unaffected. Extensor burst duration significantly decreased with increasing speed, whereas sartorius burst duration remained unchanged. Stride length, step length, and the relative distance of the paw at stance offset significantly increased with increasing speed, whereas the relative distance at stance onset and both the temporal and spatial phasing between hindlimbs were unaffected. Both temporal and spatial step-to-step left-right asymmetry decreased with increasing speed. Therefore, the spinal cord is capable of adjusting both temporal and spatial parameters during treadmill locomotion, and it is responsible, at least in part, for the step-to-step variability in left-right symmetry observed at slow speeds. PMID:26084910
Insect-computer hybrid legged robot with user-adjustable speed, step length and walking gait.
Cao, Feng; Zhang, Chao; Choo, Hao Yu; Sato, Hirotaka
2016-03-01
We have constructed an insect-computer hybrid legged robot using a living beetle (Mecynorrhina torquata; Coleoptera). The protraction/retraction and levation/depression motions in both forelegs of the beetle were elicited by electrically stimulating eight corresponding leg muscles via eight pairs of implanted electrodes. To perform a defined walking gait (e.g., gallop), different muscles were individually stimulated in a predefined sequence using a microcontroller. Different walking gaits were performed by reordering the applied stimulation signals (i.e., applying different sequences). By varying the duration of the stimulation sequences, we successfully controlled the step frequency and hence the beetle's walking speed. To the best of our knowledge, this paper presents the first demonstration of living insect locomotion control with a user-adjustable walking gait, step length and walking speed. © 2016 The Author(s).
Insect–computer hybrid legged robot with user-adjustable speed, step length and walking gait
Cao, Feng; Zhang, Chao; Choo, Hao Yu
2016-01-01
We have constructed an insect–computer hybrid legged robot using a living beetle (Mecynorrhina torquata; Coleoptera). The protraction/retraction and levation/depression motions in both forelegs of the beetle were elicited by electrically stimulating eight corresponding leg muscles via eight pairs of implanted electrodes. To perform a defined walking gait (e.g. gallop), different muscles were individually stimulated in a predefined sequence using a microcontroller. Different walking gaits were performed by reordering the applied stimulation signals (i.e. applying different sequences). By varying the duration of the stimulation sequences, we successfully controlled the step frequency and hence the beetle's walking speed. To the best of our knowledge, this paper presents the first demonstration of living insect locomotion control with a user-adjustable walking gait, step length and walking speed. PMID:27030043
Apparent power-law distributions in animal movements can arise from intraspecific interactions
Breed, Greg A.; Severns, Paul M.; Edwards, Andrew M.
2015-01-01
Lévy flights have gained prominence for analysis of animal movement. In a Lévy flight, step-lengths are drawn from a heavy-tailed distribution such as a power law (PL), and a large number of empirical demonstrations have been published. Others, however, have suggested that animal movement is ill fit by PL distributions or contend a state-switching process better explains apparent Lévy flight movement patterns. We used a mix of direct behavioural observations and GPS tracking to understand step-length patterns in females of two related butterflies. We initially found movement in one species (Euphydryas editha taylori) was best fit by a bounded PL, evidence of a Lévy flight, while the other (Euphydryas phaeton) was best fit by an exponential distribution. Subsequent analyses introduced additional candidate models and used behavioural observations to sort steps based on intraspecific interactions (interactions were rare in E. phaeton but common in E. e. taylori). These analyses showed a mixed-exponential is favoured over the bounded PL for E. e. taylori and that when step-lengths were sorted into states based on the influence of harassing conspecific males, both states were best fit by simple exponential distributions. The direct behavioural observations allowed us to infer the underlying behavioural mechanism is a state-switching process driven by intraspecific interactions rather than a Lévy flight. PMID:25519992
Adaptive control of center of mass (global) motion and its joint (local) origin in gait.
Yang, Feng; Pai, Yi-Chung
2014-08-22
Dynamic gait stability can be quantified by the relationship of the motion state (i.e. the position and velocity) between the body center of mass (COM) and its base of support (BOS). Humans learn how to adaptively control stability by regulating the absolute COM motion state (i.e. its position and velocity) and/or by controlling the BOS (through stepping) in a predictable manner, or by doing both simultaneously following an external perturbation that disrupts their regular relationship. Post repeated-slip perturbation training, for instance, older adults learned to forward shift their COM position while walking with a reduced step length, hence reduced their likelihood of slip-induced falls. How and to what extent each individual joint influences such adaptive alterations is mostly unknown. A three-dimensional individualized human kinematic model was established. Based on the human model, sensitivity analysis was used to systematically quantify the influence of each lower limb joint on the COM position relative to the BOS and the step length during gait. It was found that the leading foot had the greatest effect on regulating the COM position relative to the BOS; and both hips bear the most influence on the step length. These findings could guide cost-effective but efficient fall-reduction training paradigm among older population. Copyright © 2014 Elsevier Ltd. All rights reserved.
Fractal analysis of lateral movement in biomembranes.
Gmachowski, Lech
2018-04-01
Lateral movement of a molecule in a biomembrane containing small compartments (0.23-μm diameter) and large ones (0.75 μm) is analyzed using a fractal description of its walk. The early time dependence of the mean square displacement varies from linear due to the contribution of ballistic motion. In small compartments, walking molecules do not have sufficient time or space to develop an asymptotic relation and the diffusion coefficient deduced from the experimental records is lower than that measured without restrictions. The model makes it possible to deduce the molecule step parameters, namely the step length and time, from data concerning confined and unrestricted diffusion coefficients. This is also possible using experimental results for sub-diffusive transport. The transition from normal to anomalous diffusion does not affect the molecule step parameters. The experimental literature data on molecular trajectories recorded at a high time resolution appear to confirm the modeled value of the mean free path length of DOPE for Brownian and anomalous diffusion. Although the step length and time give the proper values of diffusion coefficient, the DOPE speed calculated as their quotient is several orders of magnitude lower than the thermal speed. This is interpreted as a result of intermolecular interactions, as confirmed by lateral diffusion of other molecules in different membranes. The molecule step parameters are then utilized to analyze the problem of multiple visits in small compartments. The modeling of the diffusion exponent results in a smooth transition to normal diffusion on entering a large compartment, as observed in experiments.
Mazaheri, Masood; Negahban, Hossein; Soltani, Maryam; Mehravar, Mohammad; Tajali, Shirin; Hessam, Masumeh; Salavati, Mahyar; Kingma, Idsart
2017-08-01
The present experiment was conducted to examine the hypothesis that challenging control through narrow-base walking and/or dual tasking affects ACL-injured adults more than healthy control adults. Twenty male ACL-injured adults and twenty healthy male adults walked on a treadmill at a comfortable speed under two base-of-support conditions, normal-base versus narrow-base, with and without a cognitive task. Gait patterns were assessed using mean and variability of step length and mean and variability of step velocity. Cognitive performance was assessed using the number of correct counts in a backward counting task. Narrow-base walking resulted in a larger decrease in step length and a more pronounced increase in variability of step length and of step velocity in ACL-injured adults than in healthy adults. For most of the gait parameters and for backward counting performance, the dual-tasking effect was similar between the two groups. ACL-injured adults adopt a more conservative and more unstable gait pattern during narrow-base walking. This can be largely explained by deficits of postural control in ACL-injured adults, which impairs gait under more balance-demanding conditions. The observation that the dual-tasking effect did not differ between the groups may be explained by the fact that walking is an automatic process that involves minimal use of attentional resources, even after ACL injury. Clinicians should consider the need to include aspects of terrain complexity, such as walking on a narrow walkway, in gait assessment and training of patients with ACL injury. III.
Efficient Inversion of Mult-frequency and Multi-Source Electromagnetic Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary D. Egbert
2007-03-22
The project covered by this report focused on development of efficient but robust non-linear inversion algorithms for electromagnetic induction data, in particular for data collected with multiple receivers, and multiple transmitters, a situation extremely common in eophysical EM subsurface imaging methods. A key observation is that for such multi-transmitter problems each step in commonly used linearized iterative limited memory search schemes such as conjugate gradients (CG) requires solution of forward and adjoint EM problems for each of the N frequencies or sources, essentially generating data sensitivities for an N dimensional data-subspace. These multiple sensitivities allow a good approximation to themore » full Jacobian of the data mapping to be built up in many fewer search steps than would be required by application of textbook optimization methods, which take no account of the multiplicity of forward problems that must be solved for each search step. We have applied this idea to a develop a hybrid inversion scheme that combines features of the iterative limited memory type methods with a Newton-type approach using a partial calculation of the Jacobian. Initial tests on 2D problems show that the new approach produces results essentially identical to a Newton type Occam minimum structure inversion, while running more rapidly than an iterative (fixed regularization parameter) CG style inversion. Memory requirements, while greater than for something like CG, are modest enough that even in 3D the scheme should allow 3D inverse problems to be solved on a common desktop PC, at least for modest (~ 100 sites, 15-20 frequencies) data sets. A secondary focus of the research has been development of a modular system for EM inversion, using an object oriented approach. This system has proven useful for more rapid prototyping of inversion algorithms, in particular allowing initial development and testing to be conducted with two-dimensional example problems, before approaching more computationally cumbersome three-dimensional problems.« less
Emergency Medicine Gender-specific Education.
Ashurst, John V; McGregor, Alyson J; Safdar, Basmah; Weaver, Kevin R; Quinn, Shawn M; Rosenau, Alex M; Goyke, Terrence E; Roth, Kevin R; Greenberg, Marna R
2014-12-01
The 2014 Academic Emergency Medicine consensus conference has taken the first step in identifying gender-specific care as an area of importance to both emergency medicine (EM) and research. To improve patient care, we need to address educational gaps in this area concurrent with research gaps. In this article, the authors highlight the need for sex- and gender-specific education in EM and propose guidelines for medical student, resident, and faculty education. Specific examples of incorporating this content into grand rounds, simulation, bedside teaching, and journal club sessions are reviewed. Future challenges and strategies to fill the gaps in the current education model are also described. © 2014 by the Society for Academic Emergency Medicine.
Seismoelectric Effects based on Spectral-Element Method for Subsurface Fluid Characterization
NASA Astrophysics Data System (ADS)
Morency, C.
2017-12-01
Present approaches for subsurface imaging rely predominantly on seismic techniques, which alone do not capture fluid properties and related mechanisms. On the other hand, electromagnetic (EM) measurements add constraints on the fluid phase through electrical conductivity and permeability, but EM signals alone do not offer information of the solid structural properties. In the recent years, there have been many efforts to combine both seismic and EM data for exploration geophysics. The most popular approach is based on joint inversion of seismic and EM data, as decoupled phenomena, missing out the coupled nature of seismic and EM phenomena such as seismoeletric effects. Seismoelectric effects are related to pore fluid movements with respect to the solid grains. By analyzing coupled poroelastic seismic and EM signals, one can capture a pore scale behavior and access both structural and fluid properties.Here, we model the seismoelectric response by solving the governing equations derived by Pride and Garambois (1994), which correspond to Biot's poroelastic wave equations and Maxwell's electromagnetic wave equations coupled electrokinetically. We will show that these coupled wave equations can be numerically implemented by taking advantage of viscoelastic-electromagnetic mathematical equivalences. These equations will be solved using a spectral-element method (SEM). The SEM, in contrast to finite-element methods (FEM) uses high degree Lagrange polynomials. Not only does this allow the technique to handle complex geometries similarly to FEM, but it also retains exponential convergence and accuracy due to the use of high degree polynomials. Finally, we will discuss how this is a first step toward full coupled seismic-EM inversion to improve subsurface fluid characterization. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
2013-01-01
Background Prior studies demonstrated that hesitation-prone persons with Parkinson’s disease (PDs) acutely improve step initiation using a novel self-triggered stimulus that enhances lateral weight shift prior to step onset. PDs showed reduced anticipatory postural adjustment (APA) durations, earlier step onsets, and faster 1st step speed immediately following stimulus exposure. Objective This study investigated the effects of long-term stimulus exposure. Methods Two groups of hesitation-prone subjects with Parkinson’s disease (PD) participated in a 6-week step-initiation training program involving one of two stimulus conditions: 1) Drop. The stance-side support surface was lowered quickly (1.5 cm); 2) Vibration. A short vibration (100 ms) was applied beneath the stance-side support surface. Stimuli were self-triggered by a 5% reduction in vertical force under the stance foot during the APA. Testing was at baseline, immediately post-training, and 6 weeks post-training. Measurements included timing and magnitude of ground reaction forces, and step speed and length. Results Both groups improved their APA force modulation after training. Contrary to previous results, neither group showed reduced APA durations or earlier step onset times. The vibration group showed 55% increase in step speed and a 39% increase in step length which were retained 6 weeks post-training. The drop group showed no stepping-performance improvements. Conclusions The acute sensitivity to the quickness-enhancing effects of stimulus exposure demonstrated in previous studies was supplanted by improved force modulation following prolonged stimulus exposure. The results suggest a potential approach to reduce the severity of start hesitation in PDs, but further study is needed to understand the relationship between short- and long-term effects of stimulus exposure. PMID:23363975
Critical Motor Number for Fractional Steps of Cytoskeletal Filaments in Gliding Assays
Li, Xin; Lipowsky, Reinhard; Kierfeld, Jan
2012-01-01
In gliding assays, filaments are pulled by molecular motors that are immobilized on a solid surface. By varying the motor density on the surface, one can control the number of motors that pull simultaneously on a single filament. Here, such gliding assays are studied theoretically using Brownian (or Langevin) dynamics simulations and taking the local force balance between motors and filaments as well as the force-dependent velocity of the motors into account. We focus on the filament stepping dynamics and investigate how single motor properties such as stalk elasticity and step size determine the presence or absence of fractional steps of the filaments. We show that each gliding assay can be characterized by a critical motor number, . Because of thermal fluctuations, fractional filament steps are only detectable as long as . The corresponding fractional filament step size is where is the step size of a single motor. We first apply our computational approach to microtubules pulled by kinesin-1 motors. For elastic motor stalks that behave as linear springs with a zero rest length, the critical motor number is found to be , and the corresponding distributions of the filament step sizes are in good agreement with the available experimental data. In general, the critical motor number depends on the elastic stalk properties and is reduced to for linear springs with a nonzero rest length. Furthermore, is shown to depend quadratically on the motor step size . Therefore, gliding assays consisting of actin filaments and myosin-V are predicted to exhibit fractional filament steps up to motor number . Finally, we show that fractional filament steps are also detectable for a fixed average motor number as determined by the surface density (or coverage) of the motors on the substrate surface. PMID:22927953
Kinematic Adaptations of Forward And Backward Walking on Land and in Water
Cadenas-Sanchez, Cristina; Arellano, Raúl; Vanrenterghem, Jos; López-Contreras, Gracia
2015-01-01
The aim of this study was to compare sagittal plane lower limb kinematics during walking on land and submerged to the hip in water. Eight healthy adults (age 22.1 ± 1.1 years, body height 174.8 ± 7.1 cm, body mass 63.4 ± 6.2 kg) were asked to cover a distance of 10 m at comfortable speed with controlled step frequency, walking forward or backward. Sagittal plane lower limb kinematics were obtained from three dimensional video analysis to compare spatiotemporal gait parameters and joint angles at selected events using two-way repeated measures ANOVA. Key findings were a reduced walking speed, stride length, step length and a support phase in water, and step length asymmetry was higher compared to the land condition (p<0.05). At initial contact, knees and hips were more flexed during walking forward in water, whilst, ankles were more dorsiflexed during walking backward in water. At final stance, knees and ankles were more flexed during forward walking, whilst the hip was more flexed during backward walking. These results show how walking in water differs from walking on land, and provide valuable insights into the development and prescription of rehabilitation and training programs. PMID:26839602
Ashtiani, Dariush; Venugopal, Hari; Belousoff, Matthew; Spicer, Bradley; Mak, Johnson; Neild, Adrian; de Marco, Alex
2018-04-06
Cryo-Electron Microscopy (cryo-EM) has become an invaluable tool for structural biology. Over the past decade, the advent of direct electron detectors and automated data acquisition has established cryo-EM as a central method in structural biology. However, challenges remain in the reliable and efficient preparation of samples in a manner which is compatible with high time resolution. The delivery of sample onto the grid is recognized as a critical step in the workflow as it is a source of variability and loss of material due to the blotting which is usually required. Here, we present a method for sample delivery and plunge freezing based on the use of Surface Acoustic Waves to deploy 6-8 µm droplets to the EM grid. This method minimises the sample dead volume and ensures vitrification within 52.6 ms from the moment the sample leaves the microfluidics chip. We demonstrate a working protocol to minimize the atomised volume and apply it to plunge freeze three different samples and provide proof that no damage occurs due to the interaction between the sample and the acoustic waves. Copyright © 2018 Elsevier Inc. All rights reserved.
Navigation and Dispersion Analysis of the First Orion Exploration Mission
NASA Technical Reports Server (NTRS)
Zanetti, Renato; D'Souza, Christopher
2015-01-01
This paper seeks to present the Orion EM-1 Linear Covariance Analysis for the DRO mission. The delta V statistics for each maneuver are presented. Included in the memo are several sensitivity analyses: variation in the time of OTC-1 (the first outbound correction maneuver), variation in the accuracy of the trans-Lunar injection, and variation in the length of the optical navigation passes.
Posture alteration as a measure to accommodate uneven ground in able-bodied gait
Blickhan, Reinhard; Muller, Roy; Rode, Christian
2017-01-01
Though the effects of imposed trunk posture on human walking have been studied, less is known about such locomotion while accommodating changes in ground level. For twelve able participants, we analyzed kinematic parameters mainly at touchdown and toe-off in walking across a 10-cm visible drop in ground level (level step, pre-perturbation step, step-down, step-up) with three postures (regular erect, ~30° and ~50° of trunk flexion from the vertical). Two-way repeated measures ANOVAs revealed step-specific effects of posture on the kinematic behavior of gait mostly at toe-off of the pre-perturbation step and the step-down as well as at touchdown of the step-up. In preparation to step-down, with increasing trunk flexion the discrepancy in hip−center of pressure distance, i.e. effective leg length, (shorter at toe-off versus touchdown), compared with level steps increased largely due to a greater knee flexion at toe-off. Participants rotated their trunk backwards during step-down (2- to 3-fold backwards rotation compared with level steps regardless of trunk posture) likely to control the angular momentum of their whole body. The more pronounced trunk backwards rotation in trunk-flexed walking contributed to the observed elevated center of mass (CoM) trajectories during the step-down which may have facilitated drop negotiation. Able-bodied individuals were found to recover almost all assessed kinematic parameters comprising the vertical position of the CoM, effective leg length and angle as well as hip, knee and ankle joint angles at the end of the step-up, suggesting an adaptive capacity and hence a robustness of human walking with respect to imposed trunk orientations. Our findings may provide clinicians with insight into a kinematic interaction between posture and locomotion in uneven ground. Moreover, a backward rotation of the trunk for negotiating step-down may be incorporated into exercise-based interventions to enhance gait stability in individuals who exhibit trunk-flexed postures during walking. PMID:29281712
Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies.
Guerin, Bastien; Serano, Peter; Iacono, Maria Ida; Herrington, Todd M; Widge, Alik S; Dougherty, Darin D; Bonmassar, Giorgio; Angelone, Leonardo M; Wald, Lawrence L
2018-05-04
We propose a framework for electromagnetic (EM) simulation of deep brain stimulation (DBS) patients in radiofrequency (RF) coils. We generated a model of a DBS patient using post-operative head and neck computed tomography (CT) images stitched together into a 'virtual CT' image covering the entire length of the implant. The body was modeled as homogeneous. The implant path extracted from the CT data contained self-intersections, which we corrected automatically using an optimization procedure. Using the CT-derived DBS path, we built a model of the implant including electrodes, helicoidal internal conductor wires, loops, extension cables, and the implanted pulse generator. We also built four simplified models with straight wires, no extension cables and no loops to assess the impact of these simplifications on safety predictions. We simulated EM fields induced by the RF birdcage body coil in the body model, including at the DBS lead tip at both 1.5 Tesla (64 MHz) and 3 Tesla (123 MHz). We also assessed the robustness of our simulation results by systematically varying the EM properties of the body model and the position and length of the DBS implant (sensitivity analysis). The topology correction algorithm corrected all self-intersection and curvature violations of the initial path while introducing minimal deformations (open-source code available at http://ptx.martinos.org/index.php/Main_Page). The unaveraged lead-tip peak SAR predicted by the five DBS models (0.1 mm resolution grid) ranged from 12.8 kW kg -1 (full model, helicoidal conductors) to 43.6 kW kg -1 (no loops, straight conductors) at 1.5 T (3.4-fold variation) and 18.6 kW kg -1 (full model, straight conductors) to 73.8 kW kg -1 (no loops, straight conductors) at 3 T (4.0-fold variation). At 1.5 T and 3 T, the variability of lead-tip peak SAR with respect to the conductivity ranged between 18% and 30%. Variability with respect to the position and length of the DBS implant ranged between 9.5% and 27.6%.
Wells, Bryan J; Roberts, Derek J; Grondin, Sean; Navsaria, Pradeep H; Kirkpatrick, Andrew W; Dunham, Michael B; Ball, Chad G
2015-09-01
Historical data suggests that many traumatic hemothoraces (HTX) can be managed expectantly without tube thoracostomy (TT) drainage. The purpose of this study was to identify predictors of TT, including whether the quantity of pleural blood predicted tube placement, and to evaluate outcomes associated with TT versus expected management (EM) of traumatic HTXs. A retrospective cohort study of all trauma patients with HTXs and an Injury Severity Score (ISS) ≥12 managed at a level I trauma centre between April 1, 2005 and December 31, 2012 was completed. Mixed-effects models with a subject-specific random intercept were used to identify independent risk factors for TT. Logistic and log-linear regression were used to compute odds ratios (ORs) for mortality and empyema and percent increases in length of hospital and intensive care unit stay between patients managed with TT versus EM, respectively. A total of 635 patients with 749 HTXs were included in the study. Overall, 491 (66%) HTXs were drained while 258 (34%) were managed expectantly. Independent predictors of TT placement included concomitant ipsilateral flail chest [OR 3.03; 95% confidence interval (CI) 1.04-8.80; p=0.04] or pneumothorax (OR 6.19; 95% CI 1.79-21.5; p<0.01) and the size of the HTX (OR per 10cc increase 1.12; 95% CI 1.04-1.21; p<0.01). Although the adjusted odds of mortality were not significantly different between groups (OR 3.99; 95% CI 0.87-18.30; p=0.08), TT was associated with a 47.14% (95% CI, 25.57-69.71%; p<0.01) adjusted increase in hospital length of stay. Empyemas (n=29) only occurred among TT patients. Expectant management of traumatic HTX was associated with a shorter length of hospital stay, no empyemas, and no increase in mortality. Although EM of smaller HTXs may be safe, these findings must be confirmed by a large multi-centre cohort study and randomized controlled trials before they are used to guide practice. Copyright © 2015 Elsevier Ltd. All rights reserved.
Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies
NASA Astrophysics Data System (ADS)
Guerin, Bastien; Serano, Peter; Iacono, Maria Ida; Herrington, Todd M.; Widge, Alik S.; Dougherty, Darin D.; Bonmassar, Giorgio; Angelone, Leonardo M.; Wald, Lawrence L.
2018-05-01
We propose a framework for electromagnetic (EM) simulation of deep brain stimulation (DBS) patients in radiofrequency (RF) coils. We generated a model of a DBS patient using post-operative head and neck computed tomography (CT) images stitched together into a ‘virtual CT’ image covering the entire length of the implant. The body was modeled as homogeneous. The implant path extracted from the CT data contained self-intersections, which we corrected automatically using an optimization procedure. Using the CT-derived DBS path, we built a model of the implant including electrodes, helicoidal internal conductor wires, loops, extension cables, and the implanted pulse generator. We also built four simplified models with straight wires, no extension cables and no loops to assess the impact of these simplifications on safety predictions. We simulated EM fields induced by the RF birdcage body coil in the body model, including at the DBS lead tip at both 1.5 Tesla (64 MHz) and 3 Tesla (123 MHz). We also assessed the robustness of our simulation results by systematically varying the EM properties of the body model and the position and length of the DBS implant (sensitivity analysis). The topology correction algorithm corrected all self-intersection and curvature violations of the initial path while introducing minimal deformations (open-source code available at http://ptx.martinos.org/index.php/Main_Page). The unaveraged lead-tip peak SAR predicted by the five DBS models (0.1 mm resolution grid) ranged from 12.8 kW kg‑1 (full model, helicoidal conductors) to 43.6 kW kg‑1 (no loops, straight conductors) at 1.5 T (3.4-fold variation) and 18.6 kW kg‑1 (full model, straight conductors) to 73.8 kW kg‑1 (no loops, straight conductors) at 3 T (4.0-fold variation). At 1.5 T and 3 T, the variability of lead-tip peak SAR with respect to the conductivity ranged between 18% and 30%. Variability with respect to the position and length of the DBS implant ranged between 9.5% and 27.6%.
Sicsic, Jonathan; Le Vaillant, Marc; Franc, Carine
2012-12-01
Like many other OECD nations, France has implemented a pay-for-performance (P4P) model in primary care. However, the benefits have been debated, particularly regarding the possibly undesirable effects of extrinsic motivation (EM) on intrinsic motivation (IM). To examine the relationship between French GPs' IM and EM based on an intrinsic motivation composite score (IMCS) developed for this purpose. If a negative relationship is found, P4P schemes could have side effects on GPs' IM that is a key determinant of quality of care. From data on 423 GPs practicing in a region of France, IM indicators are selected using a multiple correspondence analysis and aggregated from a multilevel model. Several doctors' characteristics have significant impacts on IMCS variability, especially group practice and salaried practice. Qualitative EM variables are negatively correlated with the IMCS: GPs who report not being satisfied with their income or feeling "often" constrained by patients' requests in terms of consultations length and office appointments obtain a lower mean IMCS than other GPs. Our results provide a cautionary message to regulators who should take into account the potential side effects of increasing EM through policies such as P4P. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Riebe, John M; Naeseth, Rodger L
1952-01-01
An investigation was made in the Langley 300-mph 7- by 10-foot tunnel to determine the aerodynamic characteristics of a refined deep-step planing-tail hull with various forebody and afterbody shapes and, for comparison, a streamline body simulating the fuselage of a modern transport airplane. The results of the tests indicated that the configurations incorporating a forebody with a length-beam ratio of 7 had lower minimum drag coefficients than the configurations incorporating a forebody with length-beam ratio of 5. The lowest minimum drag coefficients, which were considerably less than that of a conventional hull and slightly less than that of a streamline body, were obtained on the length-beam-ratio-7 forebody, alone and with round center boom. Drag coefficients and longitudinal- and lateral-stability parameters presented include the interference of a 21-percent-thick support wing.
NASA Technical Reports Server (NTRS)
Proise, M.
1994-01-01
Grumman, under contract to the Army Corps of Engineers, completed a System Concept Definition (SCD) study to design a high-speed 134 m/s (300 m.p.h.) magnetically levitated (Maglev) transportation system. The primary development goals were to design a Maglev that is safe, reliable, environmentally acceptable, and low-cost. The cost issue was a predominant one, since previous studies have shown that an economically viable Maglev system (one that is attractive to investors for future models of passenger and/or freight transportation) requires a cost that is about $12.4 M/km ($20 Million per mile). The design is based on the electromagnetic suspension (EMS) system using superconducting iron-core magnets mounted along both sides of the vehicle. The EMS system has several advantages compared to the electrodynamic suspension (EDS) Maglev systems such as low stray magnetic fields in the passenger cabin and the surrounding areas, uniform load distribution along the full length of the vehicle, and small pole pitch for smoother propulsion and ride comfort. It is also levitated at all speeds and incorporates a wrap-around design of safer operation. The Grumman design has all the advantages of an EMS system identified above, while eliminating (or significantly improving) drawbacks associated with normal magnet powered EMS systems. Improvements include larger gap clearance, lighter weight, lower number of control servos, and higher off line switching speeds. The design also incorporates vehicle tilt (plus or minus 9 deg) for higher coordinated turn and turn out speed capability.
Electromigration in Cu(Al) and Cu(Mn) damascene lines
NASA Astrophysics Data System (ADS)
Hu, C.-K.; Ohm, J.; Gignac, L. M.; Breslin, C. M.; Mittal, S.; Bonilla, G.; Edelstein, D.; Rosenberg, R.; Choi, S.; An, J. J.; Simon, A. H.; Angyal, M. S.; Clevenger, L.; Maniscalco, J.; Nogami, T.; Penny, C.; Kim, B. Y.
2012-05-01
The effects of impurities, Mn or Al, on interface and grain boundary electromigration (EM) in Cu damascene lines were investigated. The addition of Mn or Al solute caused a reduction in diffusivity at the Cu/dielectric cap interface and the EM activation energies for both Cu-alloys were found to increase by about 0.2 eV as compared to pure Cu. Mn mitigated and Al enhanced Cu grain boundary diffusion; however, no significant mitigation in Cu grain boundary diffusion was observed in low Mn concentration samples. The activation energies for Cu grain boundary diffusion were found to be 0.74 ± 0.05 eV and 0.77 ± 0.05 eV for 1.5 μm wide polycrystalline lines with pure Cu and Cu (0.5 at. % Mn) seeds, respectively. The effective charge number in Cu grain boundaries Z*GB was estimated from drift velocity and was found to be about -0.4. A significant enhancement in EM lifetimes for Cu(Al) or low Mn concentration bamboo-polycrystalline and near-bamboo grain structures was observed but not for polycrystalline-only alloy lines. These results indicated that the existence of bamboo grains in bamboo-polycrystalline lines played a critical role in slowing down the EM-induced void growth rate. The bamboo grains act as Cu diffusion blocking boundaries for grain boundary mass flow, thus generating a mechanical stress-induced back flow counterbalancing the EM force, which is the equality known as the "Blech short length effect."
Effect of strain on actomyosin kinetics in isometric muscle fibers.
Siththanandan, V B; Donnelly, J L; Ferenczi, M A
2006-05-15
Investigations were conducted into the biochemical and mechanical states of cross-bridges during isometric muscle contraction. Rapid length steps (3 or 6 nm hs(-1)) were applied to rabbit psoas fibers, permeabilized and isometric, at either 12 degrees C or 20 degrees C. Fibers were activated by photolysis of P(3)-1-(2-nitrophenyl)-ethyl ester of ATP infused into rigor fibers at saturating Ca(2+). Sarcomere length, tension, and phosphate release were recorded-the latter using the MDCC-PBP fluorescent probe. A reduction in strain, induced by a rapid release step, produced a short-lived acceleration of phosphate release. Rates of the phosphate transient and that of phases 3 and 4 of tension recovery were unaffected by step size but were elevated at higher temperatures. In contrast the amplitude of the phosphate transient was smaller at 20 degrees C than 12 degrees C. The presence of 0.5 or 1.0 mM added ADP during a release step reduced both the rate of tension recovery and the poststep isometric tension. A kinetic scheme is presented to simulate the observed data and to precisely determine the rate constants for the elementary steps of the ATPase cycle.
NASA Astrophysics Data System (ADS)
Han, S. T.; Shu, X. D.; Shchukin, V.; Kozhevnikova, G.
2018-06-01
In order to achieve reasonable process parameters in forming multi-step shaft by cross wedge rolling, the research studied the rolling-forming process multi-step shaft on the DEFORM-3D finite element software. The interactive orthogonal experiment was used to study the effect of the eight parameters, the first section shrinkage rate φ1, the first forming angle α1, the first spreading angle β1, the first spreading length L1, the second section shrinkage rate φ2, the second forming angle α2, the second spreading angle β2 and the second spreading length L2, on the quality of shaft end and the microstructure uniformity. By using the fuzzy mathematics comprehensive evaluation method and the extreme difference analysis, the influence degree of the process parameters on the quality of the multi-step shaft is obtained: β2>φ2L1>α1>β1>φ1>α2L2. The results of the study can provide guidance for obtaining multi-stepped shaft with high mechanical properties and achieving near net forming without stub bar in cross wedge rolling.
Directly reconstructing principal components of heterogeneous particles from cryo-EM images.
Tagare, Hemant D; Kucukelbir, Alp; Sigworth, Fred J; Wang, Hongwei; Rao, Murali
2015-08-01
Structural heterogeneity of particles can be investigated by their three-dimensional principal components. This paper addresses the question of whether, and with what algorithm, the three-dimensional principal components can be directly recovered from cryo-EM images. The first part of the paper extends the Fourier slice theorem to covariance functions showing that the three-dimensional covariance, and hence the principal components, of a heterogeneous particle can indeed be recovered from two-dimensional cryo-EM images. The second part of the paper proposes a practical algorithm for reconstructing the principal components directly from cryo-EM images without the intermediate step of calculating covariances. This algorithm is based on maximizing the posterior likelihood using the Expectation-Maximization algorithm. The last part of the paper applies this algorithm to simulated data and to two real cryo-EM data sets: a data set of the 70S ribosome with and without Elongation Factor-G (EF-G), and a data set of the influenza virus RNA dependent RNA Polymerase (RdRP). The first principal component of the 70S ribosome data set reveals the expected conformational changes of the ribosome as the EF-G binds and unbinds. The first principal component of the RdRP data set reveals a conformational change in the two dimers of the RdRP. Copyright © 2015 Elsevier Inc. All rights reserved.
'Speaking Truth' Protects Underrepresented Minorities' Intellectual Performance and Safety in STEM.
Ben-Zeev, Avi; Paluy, Yula; Milless, Katlyn L; Goldstein, Emily J; Wallace, Lyndsey; Márquez-Magaña, Leticia; Bibbins-Domingo, Kirsten; Estrada, Mica
2017-06-01
We offer and test a brief psychosocial intervention, Speaking Truth to EmPower (STEP), designed to protect underrepresented minorities' (URMs) intellectual performance and safety in science, technology, engineering, and math (STEM). STEP takes a 'knowledge as power' approach by: (a) providing a tutorial on stereotype threat (i.e., a social contextual phenomenon, implicated in underperformance and early exit) and (b) encouraging URMs to use lived experiences for generating be-prepared coping strategies. Participants were 670 STEM undergraduates [URMs (Black/African American and Latina/o) and non-URMs (White/European American and Asian/Asian American)]. STEP protected URMs' abstract reasoning and class grades (adjusted for grade point average [GPA]) as well as decreased URMs' worries about confirming ethnic/racial stereotypes. STEP's two-pronged approach-explicating the effects of structural 'isms' while harnessing URMs' existing assets-shows promise in increasing diversification and equity in STEM.
Yoo, Ha-Na; Chung, Eunjung; Lee, Byoung-Hee
2013-07-01
[Purpose] The purpose of this study was to determine the effects of augmented reality-based Otago exercise on balance, gait, and falls efficacy of elderly women. [Subjects] The subjects were 21 elderly women, who were randomly divided into two groups: an augmented reality-based Otago exercise group of 10 subjects and an Otago exercise group of 11 subjects. [Methods] All subjects were evaluated for balance (Berg Balance Scale, BBS), gait parameters (velocity, cadence, step length, and stride length), and falls efficacy. Within 12 weeks, Otago exercise for muscle strengthening and balance training was conducted three times, for a period of 60 minutes each, and subjects in the experimental group performed augmented reality-based Otago exercise. [Results] Following intervention, the augmented reality-based Otago exercise group showed significant increases in BBS, velocity, cadence, step length (right side), stride length (right side and left side) and falls efficacy. [Conclusion] The results of this study suggest the feasibility and suitability of this augmented reality-based Otago exercise for elderly women.
Evaluation of telomere length in human cardiac tissues using cardiac quantitative FISH.
Sharifi-Sanjani, Maryam; Meeker, Alan K; Mourkioti, Foteini
2017-09-01
Telomere length has been correlated with various diseases, including cardiovascular disease and cancer. The use of currently available telomere-length measurement techniques is often restricted by the requirement of a large amount of cells (Southern-based techniques) or the lack of information on individual cells or telomeres (PCR-based methods). Although several methods have been used to measure telomere length in tissues as a whole, the assessment of cell-type-specific telomere length provides valuable information on individual cell types. The development of fluorescence in situ hybridization (FISH) technologies enables the quantification of telomeres in individual chromosomes, but the use of these methods is dependent on the availability of isolated cells, which prevents their use with fixed archival samples. Here we describe an optimized quantitative FISH (Q-FISH) protocol for measuring telomere length that bypasses the previous limitations by avoiding contributions from undesired cell types. We have used this protocol on small paraffin-embedded cardiac-tissue samples. This protocol describes step-by-step procedures for tissue preparation, permeabilization, cardiac-tissue pretreatment and hybridization with a Cy3-labeled telomeric repeat complementing (CCCTAA) 3 peptide nucleic acid (PNA) probe coupled with cardiac-specific antibody staining. We also describe how to quantify telomere length by means of the fluorescence intensity and area of each telomere within individual nuclei. This protocol provides comparative cell-type-specific telomere-length measurements in relatively small human cardiac samples and offers an attractive technique to test hypotheses implicating telomere length in various cardiac pathologies. The current protocol (from tissue collection to image procurement) takes ∼28 h along with three overnight incubations. We anticipate that the protocol could be easily adapted for use on different tissue types.
Structure of the full-length TRPV2 channel by cryo-EM
NASA Astrophysics Data System (ADS)
Huynh, Kevin W.; Cohen, Matthew R.; Jiang, Jiansen; Samanta, Amrita; Lodowski, David T.; Zhou, Z. Hong; Moiseenkova-Bell, Vera Y.
2016-03-01
Transient receptor potential (TRP) proteins form a superfamily Ca2+-permeable cation channels regulated by a range of chemical and physical stimuli. Structural analysis of a `minimal' TRP vanilloid subtype 1 (TRPV1) elucidated a mechanism of channel activation by agonists through changes in its outer pore region. Though homologous to TRPV1, other TRPV channels (TRPV2-6) are insensitive to TRPV1 activators including heat and vanilloids. To further understand the structural basis of TRPV channel function, we determined the structure of full-length TRPV2 at ~5 Å resolution by cryo-electron microscopy. Like TRPV1, TRPV2 contains two constrictions, one each in the pore-forming upper and lower gates. The agonist-free full-length TRPV2 has wider upper and lower gates compared with closed and agonist-activated TRPV1. We propose these newly revealed TRPV2 structural features contribute to diversity of TRPV channels.
Structure of the full-length TRPV2 channel by cryo-EM
Huynh, Kevin W.; Cohen, Matthew R.; Jiang, Jiansen; Samanta, Amrita; Lodowski, David T.; Zhou, Z. Hong; Moiseenkova-Bell, Vera Y.
2016-01-01
Transient receptor potential (TRP) proteins form a superfamily Ca2+-permeable cation channels regulated by a range of chemical and physical stimuli. Structural analysis of a ‘minimal' TRP vanilloid subtype 1 (TRPV1) elucidated a mechanism of channel activation by agonists through changes in its outer pore region. Though homologous to TRPV1, other TRPV channels (TRPV2–6) are insensitive to TRPV1 activators including heat and vanilloids. To further understand the structural basis of TRPV channel function, we determined the structure of full-length TRPV2 at ∼5 Å resolution by cryo-electron microscopy. Like TRPV1, TRPV2 contains two constrictions, one each in the pore-forming upper and lower gates. The agonist-free full-length TRPV2 has wider upper and lower gates compared with closed and agonist-activated TRPV1. We propose these newly revealed TRPV2 structural features contribute to diversity of TRPV channels. PMID:27021073
Structure of the full-length TRPV2 channel by cryo-EM.
Huynh, Kevin W; Cohen, Matthew R; Jiang, Jiansen; Samanta, Amrita; Lodowski, David T; Zhou, Z Hong; Moiseenkova-Bell, Vera Y
2016-03-29
Transient receptor potential (TRP) proteins form a superfamily Ca(2+)-permeable cation channels regulated by a range of chemical and physical stimuli. Structural analysis of a 'minimal' TRP vanilloid subtype 1 (TRPV1) elucidated a mechanism of channel activation by agonists through changes in its outer pore region. Though homologous to TRPV1, other TRPV channels (TRPV2-6) are insensitive to TRPV1 activators including heat and vanilloids. To further understand the structural basis of TRPV channel function, we determined the structure of full-length TRPV2 at ∼5 Å resolution by cryo-electron microscopy. Like TRPV1, TRPV2 contains two constrictions, one each in the pore-forming upper and lower gates. The agonist-free full-length TRPV2 has wider upper and lower gates compared with closed and agonist-activated TRPV1. We propose these newly revealed TRPV2 structural features contribute to diversity of TRPV channels.
Tilney, L G; Tilney, M S; Cotanche, D A
1988-02-01
The stereocilia on each hair cell are arranged into rows of ascending height, resulting in what we refer to as a "staircase-like" profile. At the proximal end of the cochlea the length of the tallest row of stereocilia in the staircase is 1.5 micron, with the shortest row only 0.3 micron. As one proceeds towards the distal end of the cochlea the length of the stereocilia progressively increases so that at the extreme distal end the length of the tallest row of the staircase is 5.5 micron and the shortest row is 2 micron. During development hair cells form their staircases in four phases of growth separated from each other by developmental time. First, stereocilia sprout from the apical surfaces of the hair cells (8-10-d embryos). Second (10-12-d embryos), what will be the longest row of the staircase begins to elongate. As the embryo gets older successive rows of stereocilia initiate elongation. Thus the staircase is set up by the sequential initiation of elongation of stereociliary rows located at increased distances from the row that began elongation. Third (12-17-d embryos), all the stereocilia in the newly formed staircase elongate until those located on the first step of the staircase have reached the prescribed length. In the final phase (17-d embryos to hatchlings) there is a progressive cessation of elongation beginning with the shortest step and followed by taller and taller rows with the tallest step stopping last. Thus, to obtain a pattern of stereocilia in rows of increasing height what transpires are progressive go signals followed by a period when all the stereocilia grow and ending with progressive stop signals. We discuss how such a sequence could be controlled.
Baetens, Tina; De Kegel, Alexandra; Palmans, Tanneke; Oostra, Kristine; Vanderstraeten, Guy; Cambier, Dirk
2013-04-01
To evaluate fall risk in stroke patients based on single- and dual-task gait analyses, and to investigate the difference between 2 cognitive tasks in the dual-task paradigm. Prospective cohort study. Rehabilitation hospitals. Subacute stroke patients (N=32), able to walk without physical/manual help with or without walking aids, while performing a verbal task. Not applicable. Functional gait measures were Functional Ambulation Categories (FAC) and use of a walking aid. Gait measures were evaluated by an electronic walkway system under single- and dual-task (DT) conditions. For the single-task, subjects were instructed to walk at their usual speed. One of the DTs was a verbal fluency dual task, whereby subjects had to walk while simultaneously enumerating as many different animals as possible. For the other DT (counting dual task), participants had to walk while performing serial subtractions. After inclusion, participants kept a 6-month falls diary. Eighteen (56.3%) of the 32 included patients fell. Ten (31.3%) were single fallers (SFs), and 8 (25%) were multiple fallers (MFs). Fallers (Fs) more frequently used a walking aid and more frequently needed an observatory person for walking safely (FAC score of 3) than nonfallers (NFs). Two gait decrement parameters in counting dual task could distinguish potential Fs from NFs: decrement in stride length percentage (P=.043) and nonparetic step length percentage (P=.047). Regarding the division in 3 groups (NFs, SFs, and MFs), only MFs had a significantly higher percentage of decrement for paretic step length (P=.023) than SFs. Examining the decrement of spatial gait characteristics (stride length and paretic and nonparetic step length) during a DT addressing working memory can identify fall-prone subacute stroke patients. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Mechanisms of Exhaust Pollutants and Plume Formation in Continuous Combustion.
1984-11-30
drop swirler. A swirled air inlet decreased flame length . Two modes of operation were observed. At higher fuel loadings, reaction could be initiated...and maintained in the recirculation zone in the shadow of the step. The net result was a shorter overall flame length . The low-pressure drop swirler...yielded a shorter flame length relative to the higher pressure drop devices. - • u mmm m -m~amkn Jm• ml AM mmmmm TABLE OF CONTENTS Section Title Page
[Main results of the Swiss study on DRGs (Casemix Study)].
Casemix, E
1989-01-01
Sponsored by the Health Administrations of nine cantons, this study was conducted by the University Institute of Social and Preventive Medicine in Lausanne in order to assess how DRGs could be used within the Swiss context. A data base mainly provided by the Swiss VESKA statistics was used. The first step provided the transformation of Swiss diagnostic and intervention codes into US codes, allowing direct use of the Yale Grouper for DRG. The second step showed that the overall performance of DRG in terms of variability reduction of the length of stay was similar to the one observed in US; there are, however, problems when the homogeneity of medicotechnical procedures for DRG is considered. The third steps showed how DRG could be used as an account unit in hospital, and how costs per DRG could be estimated. Other examples of applications of DRG were examined, for example comparison of Casemix or length of stay between hospitals.
The SMM Model as a Boundary Value Problem Using the Discrete Diffusion Equation
NASA Technical Reports Server (NTRS)
Campbell, Joel
2007-01-01
A generalized single step stepwise mutation model (SMM) is developed that takes into account an arbitrary initial state to a certain partial difference equation. This is solved in both the approximate continuum limit and the more exact discrete form. A time evolution model is developed for Y DNA or mtDNA that takes into account the reflective boundary modeling minimum microsatellite length and the original difference equation. A comparison is made between the more widely known continuum Gaussian model and a discrete model, which is based on modified Bessel functions of the first kind. A correction is made to the SMM model for the probability that two individuals are related that takes into account a reflecting boundary modeling minimum microsatellite length. This method is generalized to take into account the general n-step model and exact solutions are found. A new model is proposed for the step distribution.
The SMM model as a boundary value problem using the discrete diffusion equation.
Campbell, Joel
2007-12-01
A generalized single-step stepwise mutation model (SMM) is developed that takes into account an arbitrary initial state to a certain partial difference equation. This is solved in both the approximate continuum limit and the more exact discrete form. A time evolution model is developed for Y DNA or mtDNA that takes into account the reflective boundary modeling minimum microsatellite length and the original difference equation. A comparison is made between the more widely known continuum Gaussian model and a discrete model, which is based on modified Bessel functions of the first kind. A correction is made to the SMM model for the probability that two individuals are related that takes into account a reflecting boundary modeling minimum microsatellite length. This method is generalized to take into account the general n-step model and exact solutions are found. A new model is proposed for the step distribution.
NASA Astrophysics Data System (ADS)
Hu, Y.; Ji, Y.; Egbert, G. D.
2015-12-01
The fictitious time domain method (FTD), based on the correspondence principle for wave and diffusion fields, has been developed and used over the past few years primarily for marine electromagnetic (EM) modeling. Here we present results of our efforts to apply the FTD approach to land and airborne TEM problems which can reduce the computer time several orders of magnitude and preserve high accuracy. In contrast to the marine case, where sources are in the conductive sea water, we must model the EM fields in the air; to allow for topography air layers must be explicitly included in the computational domain. Furthermore, because sources for most TEM applications generally must be modeled as finite loops, it is useful to solve directly for the impulse response appropriate to the problem geometry, instead of the point-source Green functions typically used for marine problems. Our approach can be summarized as follows: (1) The EM diffusion equation is transformed to a fictitious wave equation. (2) The FTD wave equation is solved with an explicit finite difference time-stepping scheme, with CPML (Convolutional PML) boundary conditions for the whole computational domain including the air and earth , with FTD domain source corresponding to the actual transmitter geometry. Resistivity of the air layers is kept as low as possible, to compromise between efficiency (longer fictitious time step) and accuracy. We have generally found a host/air resistivity contrast of 10-3 is sufficient. (3)A "Modified" Fourier Transform (MFT) allow us recover system's impulse response from the fictitious time domain to the diffusion (frequency) domain. (4) The result is multiplied by the Fourier transformation (FT) of the real source current avoiding time consuming convolutions in the time domain. (5) The inverse FT is employed to get the final full waveform and full time response of the system in the time domain. In general, this method can be used to efficiently solve most time-domain EM simulation problems for non-point sources.
The EM SSAB Annual Work Plan Process: Focusing Board Efforts and Resources - 13667
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, Ralph
One of the most daunting tasks for any new member of a local board of the Environmental Management Site Specific Advisory Board (EM SSAB) is to try to understand the scope of the clean-up activities going on at the site. In most cases, there are at least two or three major cleanup activities in progress as well as monitoring of past projects. When planning for future projects is added to the mix, the list of projects can be long. With the clean-up activities involving all major environmental media - air, water, soils, and groundwater, new EM SSAB members can findmore » themselves totally overwhelmed and ineffective. Helping new members get over this initial hurdle is a major objective of EM and all local boards of the EM SSAB. Even as members start to understand the size and scope of the projects at a site, they can still be frustrated at the length of time it takes to see results and get projects completed. Many project and clean-up timelines for most of the sites go beyond 10 years, so it's not unusual for an EM SSAB member to see the completion of only 1 or 2 projects over the course of their 6-year term on the board. This paper explores the annual work planning process of the EM SSAB local boards, one tool that can be used to educate EM SSAB members into seeing the broader picture for the site. EM SSAB local work plans divide the site into projects focused on a specific environmental issue or media such as groundwater and/or waste disposal options. Projects are further broken down into smaller segments by highlighting major milestones. Using these metrics, local boards of the EM SSAB can start to quantify the effectiveness of the project in achieving the ultimate goal of site clean-up. These metrics can also trigger board advice and recommendations for EM. At the beginning of each fiscal year, the EM SSAB work plan provides a road map with quantifiable checkpoints for activities throughout the year. When the work plans are integrated with site-specific, enforceable regulatory milestones, they can provide a comprehensive work plan for not only the board, but also regulators, site contractors, and DOE. Because the work plans are reviewed and approved by DOE, they carry some weight in holding local boards of the EM SSAB accountable. This structure provides the basis for local boards to achieve their primary function, to provide DOE with information, advice, and recommendations concerning issues affecting the EM program at the site. (authors)« less
Orion Optical Navigation Progress Toward Exploration Mission 1
NASA Technical Reports Server (NTRS)
Holt, Greg N.; D'Souza, Christopher N.; Saley, David
2018-01-01
Optical navigation of human spacecraft was proposed on Gemini and implemented successfully on Apollo as a means of autonomously operating the vehicle in the event of lost communication with controllers on Earth. The Orion emergency return system utilizing optical navigation has matured in design over the last several years, and is currently undergoing the final implementation and test phase in preparation for Exploration Mission 1 (EM-1) in 2019. The software development is past its Critical Design Review, and is progressing through test and certification for human rating. The filter architecture uses a square-root-free UDU covariance factorization. Linear Covariance Analysis (LinCov) was used to analyze the measurement models and the measurement error models on a representative EM-1 trajectory. The Orion EM-1 flight camera was calibrated at the Johnson Space Center (JSC) electro-optics lab. To permanently stake the focal length of the camera a 500 mm focal length refractive collimator was used. Two Engineering Design Unit (EDU) cameras and an EDU star tracker were used for a live-sky test in Denver. In-space imagery with high-fidelity truth metadata is rare so these live-sky tests provide one of the closest real-world analogs to operational use. A hardware-in-the-loop test rig was developed in the Johnson Space Center Electro-Optics Lab to exercise the OpNav system prior to integrated testing on the Orion vehicle. The software is verified with synthetic images. Several hundred off-nominal images are also used to analyze robustness and fault detection in the software. These include effects such as stray light, excess radiation damage, and specular reflections, and are used to help verify the tuning parameters chosen for the algorithms such as earth atmosphere bias, minimum pixel intensity, and star detection thresholds.
Nature of KaiB-KaiC binding in the cyanobacterial circadian oscillator
Pattanayek, Rekha; Yadagiri, Kirthi Kiran; Ohi, Melanie D.; Egli, Martin
2013-01-01
In the cyanobacteria Synechococcus elongatus and Thermosynechococcus elongatus, the KaiA, KaiB and KaiC proteins in the presence of ATP generate a post-translational oscillator (PTO) that can be reconstituted in vitro. KaiC is the result of a gene duplication and resembles a double doughnut with N-terminal CI and C-terminal CII hexameric rings. Six ATPs are bound between subunits in both the CI and CII ring. CI harbors ATPase activity, and CII catalyzes phosphorylation and dephosphorylation at T432 and S431 with a ca. 24-h period. KaiA stimulates KaiC phosphorylation, and KaiB promotes KaiC subunit exchange and sequesters KaiA on the KaiB-KaiC interface in the final stage of the clock cycle. Studies of the PTO protein-protein interactions are convergent in terms of KaiA binding to CII but have led to two opposing models of the KaiB-KaiC interaction. Electron microscopy (EM) and small angle X-ray scattering (SAXS), together with native PAGE using full-length proteins and separate CI and CII rings, are consistent with binding of KaiB to CII. Conversely, NMR together with gel filtration chromatography and denatured PAGE using monomeric CI and CII domains support KaiB binding to CI. To resolve the existing controversy, we studied complexes between KaiB and gold-labeled, full-length KaiC with negative stain EM. The EM data clearly demonstrate that KaiB contacts the CII ring. Together with the outcomes of previous analyses, our work establishes that only CII participates in interactions with KaiA and KaiB as well as with the His kinase SasA involved in the clock output pathway. PMID:23388462
McAllister, Chris T; Duszynski, Donald W; Austin, Christopher C; Fisher, Robert N
2017-02-01
Between September and November 1991, 54 adult skinks from 15 species were collected by hand or blowpipe from several localities on Rarotonga, Cook Islands, Ovalau Island, Fiji, and Papua New Guinea (PNG), and their feces were examined for coccidians. Species included 5 seaside skinks (Emoia atrocostata), 1 Pacific blue-tailed skink (Emoia caeroleocauda), 2 Fiji slender treeskinks (Emoia concolor), 15 white-bellied copper-striped skinks (Emoia cyanura), 1 Bulolo River forest skink (Emoia guttata), 6 dark-bellied copper-striped skinks (Emoia impar), 5 Papua five-striped skinks (Emoia jakati), 2 Papua slender treeskinks (Emoia kordoana), 3 Papua robust treeskinks (Emoia longicauda), 1 brown-backed forest skink (Emoia loveridgei), 3 Papua black-sided skinks (Emoia pallidiceps), 2 Papua white-spotted skinks (Emoia physicae), 2 Papua yellow-head skinks (Emoia popei), 1 Papua brown forest skink (Emoia submetallica), and 5 Fiji barred treeskinks (Emoia trossula) Species of Eimeria (Ei.) were detected from these Emoia (Em.) spp. and are described here as new. Oocysts of Eimeria iovai n. sp. from Em. pallidiceps from PNG were ellipsoidal with a bilayered wall (L × W) 26.5 × 18.1 μm, with a length/width ratio (L/W) of 1.1. Both micropyle and oocyst residuum were absent, but a fragmented polar granule was present. This eimerian also was found in Em. atrocostata from PNG. Oocysts of Eimeria kirkpatricki n. sp. from Em. atrocostata from PNG were ellipsoidal with a bilayered wall, 18.6 × 13.5 μm, L/W 1.4. A micropyle and oocyst residuum were absent, but a fragmented polar granule was present. This eimerian was also shared by Em. cyanura from the Cook Islands and Fiji, Em. impar from the Cook Islands, Em. loveridgei from PNG, Em. pallidiceps from PNG, Em. popei from PNG, and Em. submetallica from PNG. Oocysts of Eimeria stevejayuptoni n. sp. from Em. longicauda were subspheroidal to ellipsoidal with a bilayered wall, 18.7 × 16.6 μm, L/W 1.1. A micropyle and oocyst residuum were absent, but a fragmented polar granule was present. Oocysts of Eimeria emoia n. sp. from Em. longicauda from PNG were cylindroidal with a bilayered wall, 29.2 × 15.7 μm, L/W 1.9. A micropyle and oocyst residuum were absent, but a polar granule was present. These are the first eimerians reported from Emoia spp. and they add to our growing knowledge of the coccidian fauna of scincid lizards of the South Pacific.
Backwards Fading to Speed Task Learning
2013-09-01
estimates.) Table 1 Finalized Task List Task Domain Task Name Knot Tying Hand Cuff Rappel First Aid Fracture Bleed Map Reading* Resection...materials used. Hand Cuff . There are 10 steps in this task. To complete this task, the learner must manipulate a short length of rope (e.g...Design for Experiment 1 – Step Fade Experiment 1 (Step Fade) Task Type: Knot Tying Task Type: First Aid Task Complexity: Low (1) Hand Cuff (10
Douglass, Katherine; Pousson, Amelia; Gidwani, Shweta; Smith, Jeffrey
2015-11-01
Emergency medicine (EM) is a recently recognized specialty in India, still in its infancy. Local training programs are developing, but remain very limited. Private, for-profit hospitals are an important provider of graduate medical education (GME) in India, and are partnering with United States (US) universities in EM to expand training opportunities. Our aim was to describe current private-sector programs affiliated with a US university providing postgraduate EM training in India, the evolution and structure of these programs, and successes and challenges of program implementation. Programs have been established in seven cities in India in partnership with a US academic institution. Full-time trainees have required didactics, clinical rotations, research, and annual examinations. Faculty members affiliated with the US institution visit each program monthly. Regular evaluations have informed program modifications, and a local faculty development program has been implemented. Currently, 240 trainees are enrolled in the EM postgraduate program, and 141 physicians have graduated. A pilot survey conducted in 2012 revealed that 93% of graduates are currently practicing EM, 82% of those in India; 71% are involved in teaching, and 32% in research. Further investigation into programmatic impacts is necessary. Challenges include issues of formal program recognition both in India and abroad. This unique partnership is playing a major early role in EM GME in India. Future steps include official program recognition, expanded numbers of training sites, and a gradual transition of training and education to local faculty. Similar partnership programs may be effective in other settings outside of India. Copyright © 2015 Elsevier Inc. All rights reserved.
Hamamoto, Kouta; Ueda, Shuhei; Yamamoto, Yoshimasa
2015-01-01
Genotyping and characterization of bacterial isolates are essential steps in the identification and control of antibiotic-resistant bacterial infections. Recently, one novel genotyping method using three genomic guided Escherichia coli markers (GIG-EM), dinG, tonB, and dipeptide permease (DPP), was reported. Because GIG-EM has not been fully evaluated using clinical isolates, we assessed this typing method with 72 E. coli collection of reference (ECOR) environmental E. coli reference strains and 63 E. coli isolates of various genetic backgrounds. In this study, we designated 768 bp of dinG, 745 bp of tonB, and 655 bp of DPP target sequences for use in the typing method. Concatenations of the processed marker sequences were used to draw GIG-EM phylogenetic trees. E. coli isolates with identical sequence types as identified by the conventional multilocus sequence typing (MLST) method were localized to the same branch of the GIG-EM phylogenetic tree. Sixteen clinical E. coli isolates were utilized as test isolates without prior characterization by conventional MLST and phylogenetic grouping before GIG-EM typing. Of these, 14 clinical isolates were assigned to a branch including only isolates of a pandemic clone, E. coli B2-ST131-O25b, and these results were confirmed by conventional typing methods. Our results suggested that the GIG-EM typing method and its application to phylogenetic trees might be useful tools for the molecular characterization and determination of the genetic relationships among E. coli isolates. PMID:25809972
Hamamoto, Kouta; Ueda, Shuhei; Yamamoto, Yoshimasa; Hirai, Itaru
2015-06-01
Genotyping and characterization of bacterial isolates are essential steps in the identification and control of antibiotic-resistant bacterial infections. Recently, one novel genotyping method using three genomic guided Escherichia coli markers (GIG-EM), dinG, tonB, and dipeptide permease (DPP), was reported. Because GIG-EM has not been fully evaluated using clinical isolates, we assessed this typing method with 72 E. coli collection of reference (ECOR) environmental E. coli reference strains and 63 E. coli isolates of various genetic backgrounds. In this study, we designated 768 bp of dinG, 745 bp of tonB, and 655 bp of DPP target sequences for use in the typing method. Concatenations of the processed marker sequences were used to draw GIG-EM phylogenetic trees. E. coli isolates with identical sequence types as identified by the conventional multilocus sequence typing (MLST) method were localized to the same branch of the GIG-EM phylogenetic tree. Sixteen clinical E. coli isolates were utilized as test isolates without prior characterization by conventional MLST and phylogenetic grouping before GIG-EM typing. Of these, 14 clinical isolates were assigned to a branch including only isolates of a pandemic clone, E. coli B2-ST131-O25b, and these results were confirmed by conventional typing methods. Our results suggested that the GIG-EM typing method and its application to phylogenetic trees might be useful tools for the molecular characterization and determination of the genetic relationships among E. coli isolates. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
NASA Astrophysics Data System (ADS)
Dabiri, Mohammad Taghi; Sadough, Seyed Mohammad Sajad
2018-04-01
In the free-space optical (FSO) links, atmospheric turbulence lead to scintillation in the received signal. Due to its ease of implementation, intensity modulation with direct detection (IM/DD) based on ON-OFF keying (OOK) is a popular signaling scheme in these systems. Over turbulence channel, to detect OOK symbols in a blind way, i.e., without sending pilot symbols, an expectation-maximization (EM)-based detection method was recently proposed in the literature related to free-space optical (FSO) communication. However, the performance of EM-based detection methods severely depends on the length of the observation interval (Ls). To choose the optimum values of Ls at target bit error rates (BER)s of FSO communications which are commonly lower than 10-9, Monte-Carlo simulations would be very cumbersome and require a very long processing time. To facilitate performance evaluation, in this letter we derive the analytic expressions for BER and outage probability. Numerical results validate the accuracy of our derived analytic expressions. Our results may serve to evaluate the optimum value for Ls without resorting to time-consuming Monte-Carlo simulations.
Conformational Dynamics inside Amino-Terminal Disease Hotspot of Ryanodine Receptor
Zhong, Xiaowei; Liu, Ying; Zhu, Li; Meng, Xing; Wang, Ruiwu; Van Petegem, Filip; Wagenknecht, Terence; Wayne Chen, S. R.; Liu, Zheng
2013-01-01
Summary The N-terminal region of both skeletal and cardiac ryanodine receptor is a disease mutation hotspot. Recently, a crystal structure of the RyR1 fragment (residues 1-559) was solved. This N-terminal structure contains three separate domains, A, B, and C, and was docked into a central vestibule in a full-length RyR1 cryo-EM map. Here we reconstructed 3D cryo-EM structures of two GFP-tagged RyR2s with GFP inserted after residue Glu-310 and Ser-437, respectively. The structures of RyR2E310-GFP and RyR2S437-GFP displayed an extra mass on domain B and C, directly validating the predicted docking model. Next, we revealed domain movements in molecular dynamics flexible fitting models in both the closed and open state cryo-EM maps. To further probe the conformational changes, we generated FRET pairs by inserting CFP or YFP in two selected domains, FRET studies of three dual-insertion pairs and three co-expressed single-insertion pairs showed the dynamic structural changes within the N-terminal domains. PMID:24139989
Predictive Variables of Half-Marathon Performance for Male Runners
Gómez-Molina, Josué; Ogueta-Alday, Ana; Camara, Jesus; Stickley, Christoper; Rodríguez-Marroyo, José A.; García-López, Juan
2017-01-01
The aims of this study were to establish and validate various predictive equations of half-marathon performance. Seventy-eight half-marathon male runners participated in two different phases. Phase 1 (n = 48) was used to establish the equations for estimating half-marathon performance, and Phase 2 (n = 30) to validate these equations. Apart from half-marathon performance, training-related and anthropometric variables were recorded, and an incremental test on a treadmill was performed, in which physiological (VO2max, speed at the anaerobic threshold, peak speed) and biomechanical variables (contact and flight times, step length and step rate) were registered. In Phase 1, half-marathon performance could be predicted to 90.3% by variables related to training and anthropometry (Equation 1), 94.9% by physiological variables (Equation 2), 93.7% by biomechanical parameters (Equation 3) and 96.2% by a general equation (Equation 4). Using these equations, in Phase 2 the predicted time was significantly correlated with performance (r = 0.78, 0.92, 0.90 and 0.95, respectively). The proposed equations and their validation showed a high prediction of half-marathon performance in long distance male runners, considered from different approaches. Furthermore, they improved the prediction performance of previous studies, which makes them a highly practical application in the field of training and performance. Key points The present study obtained four equations involving anthropometric, training, physiological and biomechanical variables to estimate half-marathon performance. These equations were validated in a different population, demonstrating narrows ranges of prediction than previous studies and also their consistency. As a novelty, some biomechanical variables (i.e. step length and step rate at RCT, and maximal step length) have been related to half-marathon performance. PMID:28630571
Tadros, Anthony S; Castillo, Edward M; Chan, Theodore C; Jensen, Anne Marie; Patel, Ekta; Watts, Kerin; Dunford, James V
2012-01-01
A small group of adults disproportionately and ineffectively use acute services including emergency medical services (EMS) and emergency departments (EDs). The resulting episodic, uncoordinated care is of lower quality and higher cost and simultaneously consumes valuable public safety and acute care resources. To address this issue, we measured the impact of a pilot, EMS-based case management and referral intervention termed the San Diego Resource Access Program (RAP) to reduce EMS, ED, and inpatient (IP) visits. This was a historical cohort study of RAP records and billing data of EMS and one urban hospital for 51 individuals sequentially enrolled in the program. The study sample consisted of adults with ≥ 10 EMS transports within 12 months and others reported by prehospital personnel with significant recent increases in transports. Data were collected over a 31-month time period from December 2006 to June 2009. Data were collected for equal pre- and postenrollment time periods based on date of initial RAP contact, and comparisons were made using the Wilcoxon signed-rank test. Overall use for subjects is reported. The majority of subjects were male (64.7%), homeless (58.8%), and 40 to 59 years of age (72.5%). Between the pre and post periods, EMS encounters declined 37.6% from 736 to 459 (p = 0.001), resulting in a 32.1% decrease in EMS charges from $689,743 to $468,394 (p = 0.004). The EMS task time and mileage decreased by 39.8% and 47.5%, respectively, accounting for 262 (p = 0.008) hours and 1,940 (p = 0.006) miles. The number of ED encounters at the one participating hospital declined 28.1% from 199 to 143, which correlated with a 12.7% decrease in charges from $413,410 to $360,779. The number of IP admissions declined by 9.1% from 33 to 30, corresponding to a 5.9% decrease in IP charges from $687,306 to $646,881. Hospital length of stay declined 27.9%, from 122 to 88 days. Across all services, total charges declined by $314,406. This pilot study demonstrated that an EMS-based case management and referral program was an effective means of decreasing EMS transports by frequent users, but had only a limited impact on use of hospital services.
NASA Astrophysics Data System (ADS)
Maneval, Daniel; Bouchard, Hugo; Ozell, Benoît; Després, Philippe
2018-01-01
The equivalent restricted stopping power formalism is introduced for proton mean energy loss calculations under the continuous slowing down approximation. The objective is the acceleration of Monte Carlo dose calculations by allowing larger steps while preserving accuracy. The fractional energy loss per step length ɛ was obtained with a secant method and a Gauss-Kronrod quadrature estimation of the integral equation relating the mean energy loss to the step length. The midpoint rule of the Newton-Cotes formulae was then used to solve this equation, allowing the creation of a lookup table linking ɛ to the equivalent restricted stopping power L eq, used here as a key physical quantity. The mean energy loss for any step length was simply defined as the product of the step length with L eq. Proton inelastic collisions with electrons were added to GPUMCD, a GPU-based Monte Carlo dose calculation code. The proton continuous slowing-down was modelled with the L eq formalism. GPUMCD was compared to Geant4 in a validation study where ionization processes alone were activated and a voxelized geometry was used. The energy straggling was first switched off to validate the L eq formalism alone. Dose differences between Geant4 and GPUMCD were smaller than 0.31% for the L eq formalism. The mean error and the standard deviation were below 0.035% and 0.038% respectively. 99.4 to 100% of GPUMCD dose points were consistent with a 0.3% dose tolerance. GPUMCD 80% falloff positions (R80 ) matched Geant’s R80 within 1 μm. With the energy straggling, dose differences were below 2.7% in the Bragg peak falloff and smaller than 0.83% elsewhere. The R80 positions matched within 100 μm. The overall computation times to transport one million protons with GPUMCD were 31-173 ms. Under similar conditions, Geant4 computation times were 1.4-20 h. The L eq formalism led to an intrinsic efficiency gain factor ranging between 30-630, increasing with the prescribed accuracy of simulations. The L eq formalism allows larger steps leading to a O(constant) algorithmic time complexity. It significantly accelerates Monte Carlo proton transport while preserving accuracy. It therefore constitutes a promising variance reduction technique for computing proton dose distributions in a clinical context.
Nadeau, Alexandra; Lungu, Ovidiu; Duchesne, Catherine; Robillard, Marie-Ève; Bore, Arnaud; Bobeuf, Florian; Plamondon, Réjean; Lafontaine, Anne-Louise; Gheysen, Freja; Bherer, Louis; Doyon, Julien
2017-01-01
Background: There is increasing evidence that executive functions and attention are associated with gait and balance, and that this link is especially prominent in older individuals or those who are afflicted by neurodegenerative diseases that affect cognition and/or motor functions. People with Parkinson’s disease (PD) often present gait disturbances, which can be reduced when PD patients engage in different types of physical exercise (PE), such as walking on a treadmill. Similarly, PE has also been found to improve executive functions in this population. Yet, no exercise intervention investigated simultaneously gait and non-motor symptoms (executive functions, motor learning) in PD patients. Objective: To assess the impact of aerobic exercise training (AET) using a stationary bicycle on a set of gait parameters (walking speed, cadence, step length, step width, single and double support time, as well as variability of step length, step width and double support time) and executive functions (cognitive inhibition and flexibility) in sedentary PD patients and healthy controls. Methods: Two groups, 19 PD patients (Hoehn and Yahr ≤2) and 20 healthy adults, matched on age and sedentary level, followed a 3-month stationary bicycle AET regimen. Results: Aerobic capacity, as well as performance of motor learning and on cognitive inhibition, increased significantly in both groups after the training regimen, but only PD patients improved their walking speed and cadence (all p < 0.05; with no change in the step length). Moreover, in PD patients, training-related improvements in aerobic capacity correlated positively with improvements in walking speed (r = 0.461, p < 0.05). Conclusion: AET using stationary bicycle can independently improve gait and cognitive inhibition in sedentary PD patients. Given that increases in walking speed were obtained through increases in cadence, with no change in step length, our findings suggest that gait improvements are specific to the type of motor activity practiced during exercise (i.e., pedaling). In contrast, the improvements seen in cognitive inhibition were, most likely, not specific to the type of training and they could be due to indirect action mechanisms (i.e., improvement of cardiovascular capacity). These results are also relevant for the development of targeted AET interventions to improve functional autonomy in PD patients. PMID:28127282
Maximum Likelihood Estimations and EM Algorithms with Length-biased Data
Qin, Jing; Ning, Jing; Liu, Hao; Shen, Yu
2012-01-01
SUMMARY Length-biased sampling has been well recognized in economics, industrial reliability, etiology applications, epidemiological, genetic and cancer screening studies. Length-biased right-censored data have a unique data structure different from traditional survival data. The nonparametric and semiparametric estimations and inference methods for traditional survival data are not directly applicable for length-biased right-censored data. We propose new expectation-maximization algorithms for estimations based on full likelihoods involving infinite dimensional parameters under three settings for length-biased data: estimating nonparametric distribution function, estimating nonparametric hazard function under an increasing failure rate constraint, and jointly estimating baseline hazards function and the covariate coefficients under the Cox proportional hazards model. Extensive empirical simulation studies show that the maximum likelihood estimators perform well with moderate sample sizes and lead to more efficient estimators compared to the estimating equation approaches. The proposed estimates are also more robust to various right-censoring mechanisms. We prove the strong consistency properties of the estimators, and establish the asymptotic normality of the semi-parametric maximum likelihood estimators under the Cox model using modern empirical processes theory. We apply the proposed methods to a prevalent cohort medical study. Supplemental materials are available online. PMID:22323840
[Growth in terms of length of Chilean infants of low socioeconomic status: 1978-1992].
Pizarro, F; Olivares, M; Hertrampf, E; Walter, T
1996-06-01
In Chile infant malnutrition is better reflected by the length/age indicator than by weight/length. In this study we will present the progression of length during the first year of life from the year 1978 through 1992 of infants of low socioeconomic status. We selected healthy infants with > 3000 g birth weight and birth length > 0.5 z. According to type of milk feedings they were defined as CM (cow milk) those who were weaned before 4 months of life and EM (exclusive breast milk) those who continued exclusive breast milk (as only source of milk solids permitted) past 6 months. Infants CM of the 1978-80 cohort had a length at birth z +0.21 reaching 1 year with z -0.65, a loss of 0.86 z. Infants from the cohorts of 1982-86 and 1988-92 fell from z +0.15 to z -0.37 (a loss of -0.52 z) and +0.16 to -0.19 (a loss of -0.45 z) between birth and 12 months respectively. EBM infants length also fell significantly (delta z: -1.12, -0.69 and 0.59 respectively). Proteincalorie nutrition was adequate confirmed with weight/age or length/weight curves with means of +0.52 throughout the first year. Analysis of the length curves by regression shows that the slopes of the 3 cohorts are significantly different (< 0.01) for CM and EBM favoring the most recent cohorts. Multiple regression analysis identified association of length at 1 year with birth weight (p < 0.05), birth length (p < 0.01) and socioeconomic index (p < 0.01). We suggest that there is an improvement in the trend of Chilean infants growth in length for the past 20 years, likely due to improvement in socioeconomic level.
Son, Nam-Kuk; Ryu, Young Uk; Jeong, Hye-Won; Jang, Young-Hwan; Kim, Hyeong-Dong
2016-01-01
Regular exercise can delay age-related risk factors and can maintain or improve physical health and activity in older adults leading to a decrease in fall risk. The purpose of this study was to compare 2 different interventions for fall prevention, tai chi (TC) and Otago, by examining lower extremity strength, balance, and spatiotemporal gait parameters in community-dwelling older women. We performed a randomized trial in which subjects were assigned to 1 of 2 groups: the TC group (n = 21; age, 72.8 ± 4.7 years, range: 65-83 years), which participated in a modified Sun-style TC exercise program; and the Otago group (n = 24; age, 71.5 ± 3.6 years, range: 65-79 years), which participated in the Otago exercise program. The Timed Up and Go (TUG) test, functional reach (FR) test, one-leg standing (OLS) test, 5 times sit-to-stand test (5×STS), 30-second sit-to-stand (30s STS) test, and gait parameters (gait velocity, step length, step width, stride time, and cadence) were measured before and after the intervention. Both groups showed statistically significant improvements in balance (TUG and OLS tests), lower extremity strength (5×STS and 30s STS tests), and spatiotemporal gait parameters, except for step width and step length (P < .05). The Otago group showed a significantly improved FR, whereas the TC group showed a significantly improved step length after the intervention (P < .05). Furthermore, the Otago group exhibited greater improvements in the TUG (P < .001), FR (P < .001), 5×CST (P < .01), and 30-second CST (P < .01) tests: a faster cadence (P < .001) and shorter stride time (P < .001) when compared with the TC group. The TC group showed greater improvements in the OLS test, step length, and step width (P < .01) and faster gait velocity (P < .05) than the Otago group. The findings from this study support the efficacy of the TC and Otago exercise programs in improving mobility in this sample of subjects. Furthermore, the Otago group showed greater improvement in lower extremity strength, whereas the TC group showed greater improvement in balance (OLS test). Also, the TC group showed a greater improvement in gait velocity after TC training program compared with the Otago exercise program. However, this study does not elucidate which exercise program is a more effective intervention method with older women for fall prevention.
Differences in physical fitness and throwing velocity among elite and amateur male handball players.
Gorostiaga, E M; Granados, C; Ibáñez, J; Izquierdo, M
2005-04-01
This study compared physical characteristics (body height, body mass [BM], body fat [BF], and free fatty mass [FFM]), one repetition maximum bench-press (1RM (BP)), jumping explosive strength (VJ), handball throwing velocity, power-load relationship of the leg and arm extensor muscles, 5- and 15-m sprint running time, and running endurance in two handball male teams: elite team, one of the world's leading teams (EM, n = 15) and amateur team, playing in the Spanish National Second Division (AM, n = 15). EM had similar values in body height, BF, VJ, 5- and 15-m sprint running time and running endurance than AM. However, the EM group gave higher values in BM (95.2 +/- 13 kg vs. 82.4 +/- 10 kg, p < 0.05), FFM (81.7 +/- 9 kg vs. 72.4 +/- 7 kg, p < 0.05), 1RM (BP) (107 +/- 12 kg vs. 83 +/- 10 kg, p < 0.001), muscle power during bench-press (18 - 21 %, p < 0.05) and half squat (13 - 17 %), and throwing velocities at standing (23.8 +/- 1.9 m . s (-1) vs. 21.8 +/- 1.6 m . s (-1), p < 0.05) and 3-step running (25.3 +/- 2.2 m . s (-1) vs. 22.9 +/- 1.4 m . s (-1), p < 0.05) actions than the AM group. Significant correlations (r = 0.67 - 0.71, p < 0.05 - 0.01) were observed in EM and AM between individual values of velocity at 30 % of 1RM (BP) and individual values of ball velocity during a standing throw. Significant correlations were observed in EM, but not in AM, between the individual values of velocity during 3-step running throw and the individual values of velocity at 30 % of 1RM (BP) (r = 0.72, p < 0.05), as well as the individual values of power at 100 % of body mass during half-squat actions (r = 0.62, p < 0.05). The present results suggest that more muscular and powerful players are at an advantage in handball. The differences observed in free fatty mass could partly explain the differences observed between groups in absolute maximal strength and muscle power. In EM, higher efficiency in handball throwing velocity may be associated with both upper and lower extremity power output capabilities, whereas in AM this relationship may be different. Endurance capacity does not seem to represent a limitation for elite performance in handball.
Shields, T P; Mollova, E; Ste Marie, L; Hansen, M R; Pardi, A
1999-01-01
An improved method is presented for the preparation of milligram quantities of homogenous-length RNAs suitable for nuclear magnetic resonance or X-ray crystallographic structural studies. Heterogeneous-length RNA transcripts are processed with a hammerhead ribozyme to yield homogenous-length products that are then readily purified by anion exchange high-performance liquid chromatography. This procedure eliminates the need for denaturing polyacrylamide gel electrophoresis, which is the most laborious step in the standard procedure for large-scale production of RNA by in vitro transcription. The hammerhead processing of the heterogeneous-length RNA transcripts also substantially improves the overall yield and purity of the desired RNA product. PMID:10496226
Walkway Length Determination for Steady State Walking in Young and Older Adults
ERIC Educational Resources Information Center
Macfarlane, Pamela A.; Looney, Marilyn A.
2008-01-01
The primary purpose of this study was to determine acceleration (AC) and deceleration (DC) distances that would accommodate young and older adults walking at their preferred and fast speeds. A secondary purpose was to determine the minimal walkway length needed to record six steady state (SS) steps (three full gait cycles) for younger and older…
NASA Astrophysics Data System (ADS)
Jeffery, David J.; Mazzali, Paolo A.
2007-08-01
Giant steps is a technique to accelerate Monte Carlo radiative transfer in optically-thick cells (which are isotropic and homogeneous in matter properties and into which astrophysical atmospheres are divided) by greatly reducing the number of Monte Carlo steps needed to propagate photon packets through such cells. In an optically-thick cell, packets starting from any point (which can be regarded a point source) well away from the cell wall act essentially as packets diffusing from the point source in an infinite, isotropic, homogeneous atmosphere. One can replace many ordinary Monte Carlo steps that a packet diffusing from the point source takes by a randomly directed giant step whose length is slightly less than the distance to the nearest cell wall point from the point source. The giant step is assigned a time duration equal to the time for the RMS radius for a burst of packets diffusing from the point source to have reached the giant step length. We call assigning giant-step time durations this way RMS-radius (RMSR) synchronization. Propagating packets by series of giant steps in giant-steps random walks in the interiors of optically-thick cells constitutes the technique of giant steps. Giant steps effectively replaces the exact diffusion treatment of ordinary Monte Carlo radiative transfer in optically-thick cells by an approximate diffusion treatment. In this paper, we describe the basic idea of giant steps and report demonstration giant-steps flux calculations for the grey atmosphere. Speed-up factors of order 100 are obtained relative to ordinary Monte Carlo radiative transfer. In practical applications, speed-up factors of order ten and perhaps more are possible. The speed-up factor is likely to be significantly application-dependent and there is a trade-off between speed-up and accuracy. This paper and past work suggest that giant-steps error can probably be kept to a few percent by using sufficiently large boundary-layer optical depths while still maintaining large speed-up factors. Thus, giant steps can be characterized as a moderate accuracy radiative transfer technique. For many applications, the loss of some accuracy may be a tolerable price to pay for the speed-ups gained by using giant steps.
Observation of electromigration in a Cu thin line by in situ coherent x-ray diffraction microscopy
NASA Astrophysics Data System (ADS)
Takahashi, Yukio; Nishino, Yoshinori; Furukawa, Hayato; Kubo, Hideto; Yamauchi, Kazuto; Ishikawa, Tetsuya; Matsubara, Eiichiro
2009-06-01
Electromigration (EM) in a 1-μm-thick Cu thin line was investigated by in situ coherent x-ray diffraction microscopy (CXDM). Characteristic x-ray speckle patterns due to both EM-induced voids and thermal deformation in the thin line were observed in the coherent x-ray diffraction patterns. Both parts of the voids and the deformation were successfully visualized in the images reconstructed from the diffraction patterns. This result not only represents the first demonstration of the visualization of structural changes in metallic materials by in situ CXDM but is also an important step toward studying the structural dynamics of nanomaterials using x-ray free-electron lasers in the near future.
Monticelli, Francesca; Osorio, Raquel; Toledano, Manuel; Ferrari, Marco; Pashley, David H; Tay, Franklin R
2010-07-01
The sealing properties of a one-step obturation post-placement technique consisting of Resilon-capped fibre post-obturators were compared with a two-step technique based on initial Resilon root filling following by 24h-delayed fibre post-placement. Thirty root segments were shaped to size 40, 0.04 taper and filled with: (1) InnoEndo obturators; (2) Resilon/24h-delayed FibreKor post-cementation. Obturator, root filling and post-cementation procedures were performed using InnoEndo bonding agent/dual-cured root canal sealer. Fluid flow rate through the filled roots was evaluated at 10psi using a computerised fluid filtration model before root resection and after 3 and 9mm apical resections. Fluid flow data were analysed using two-way repeated measures ANOVA and Tukey test to examine the effects of root-filling post-placement techniques and root resection lengths on fluid leakage from the filled canals (alpha=0.05). A significantly greater amount of fluid leakage was observed with the one-step technique when compared with two-step technique. No difference in fluid leakage was observed among intact canals and canals resected at different lengths for both materials. The seal of root canals achieved with the one-step obturator is less effective than separate Resilon root fillings followed by a 24-h delay prior to the fibre post-placement. Incomplete setting of the sealer and restricted relief of polymerisation shrinkage stresses may be responsible for the inferior seal of the one-step root-filling/post-restoration technique. Copyright 2010 Elsevier Ltd. All rights reserved.
Ayazi, Shahin; Tamhankar, Anand; DeMeester, Steven R; Zehetner, Joerg; Wu, Calvin; Lipham, John C; Hagen, Jeffrey A; DeMeester, Tom R
2010-07-01
The lower esophageal sphincter (LES) in patients with gastroesophageal reflux disease often has a low resting pressure and a short abdominal length. The mechanism by which this occurs is unknown. We hypothesize that gastric distension causes progressive effacement of the abdominal portion of the LES, exposing it to acid injury resulting in mucosal and sphincter damage. Our aim was to assess in normal subjects the effect of gastric distension on the LES length and pressure and its exposure to acid gastric juice. Eleven asymptomatic volunteers had their LES length and pressure measured before and during gastric distension. The location of the pH step-up point (shift from gastric pH to a pH >4) was also measured before and after distension. Progressive gastric distension with air resulted in progressive shortening of LES (R = 0.89, P < 0.0001). After infusion of 750 cc of air there was a significant reduction in the median LES length from 4 to 2.6 cm (P = 0.001). This change occurred in the abdominal length of the LES (2.6-1.4 cm [P = 0.001]) and not in the thoracic length. At rest the pH step-up point was 0.5 cm above the lower border of the LES and with distension moved a median of 1 cm cephalad within the LES. Simultaneously with the loss of length there was a reduction in LES pressure (27.4-23.4 mm Hg, P = 0.02). Gastric distension causes progressive shortening of the abdominal length of the LES and a reduction in its pressure. The process exposes the effaced mucosa and sphincter to acid gastric juice.
NASA Astrophysics Data System (ADS)
Grigoriev, V. F.; Korotaev, S. M.; Kruglyakov, M. S.; Orekhova, D. A.; Popova, I. V.; Tereshchenko, E. D.; Tereshchenko, P. E.; Schors, Yu. G.
2013-05-01
The first Russian six-component seafloor electromagnetic (EM) receivers were tested in an experiment carried out in Kola Bay in the Barents Sea. The signals transmitted by a remote high-power ELF source at several frequencies in the decahertz range were recorded by six receivers deployed on the seafloor along the profile crossing the Kola Bay. Although not all the stations successfully recorded all the six components due to technical failures, the quality of the data overall is quite suitable for interpretation. The interpretation was carried out by the three-dimensional (3D) modeling of an electromagnetic field with neural network inversion. The a priori geoelectrical model of Kola Bay, which was reconstructed by generalizing the previous geological and geophysical data, including the data of the ground magnetotelluric sounding and magnetovariational profiling, provided the EM fields that are far from those measured in the experiment. However, by a step-by-step modification of the initial model, we achieved quite a satisfactory fit. The resulting model provides the basis for introducing the corrections into the previous notions concerning the regional geological and geophysical structure of the region and particularly the features associated with fault tectonics.
NASA Astrophysics Data System (ADS)
Stolzenburg, Maribeth; Marshall, Thomas C.; Karunarathne, Sumedhe; Orville, Richard E.
2018-10-01
Using video data recorded at 50,000 frames per second for nearby negative lightning flashes, estimates are derived for the length of positive upward connecting leaders (UCLs) that presumably formed prior to new ground attachments. Return strokes were 1.7 to 7.8 km distant, yielding image resolutions of 4.25 to 19.5 m. No UCLs are imaged in these data, indicating those features were too transient or too dim compared to other lightning processes that are imaged at these resolutions. Upper bound lengths for 17 presumed UCLs are determined from the height above flat ground or water of the successful stepped leader tip in the image immediately prior to (within 20 μs before) the return stroke. Better estimates of maximum UCL lengths are determined using the downward stepped leader tip's speed of advance and the estimated return stroke time within its first frame. For 17 strokes, the upper bound length of the possible UCL averages 31.6 m and ranges from 11.3 to 50.3 m. Among the close strokes (those with spatial resolution <8 m per pixel), the five which connected to water (salt water lagoon) have UCL upper bound estimates averaging significantly shorter (24.1 m) than the average for the three close strokes which connected to land (36.9 m). The better estimates of maximum UCL lengths for the eight close strokes average 20.2 m, with slightly shorter average of 18.3 m for the five that connected to water. All the better estimates of UCL maximum lengths are <38 m in this dataset
Demographics and Fellowship Training of Residency Leadership in EM: A Descriptive Analysis.
Greenstein, Josh; Hardy, Ross; Chacko, Jerel; Husain, Abbas
2017-01-01
Emergency medicine (EM) fellowships are becoming increasingly numerous, and there is a growing trend among EM residents to pursue postgraduate fellowship training. Scant data have been published on the prevalence of postgraduate training among emergency physicians. We aimed to describe the prevalence and regional variation of fellowships among EM residency leadership. We conducted an online anonymous survey that was sent to the Council of EM Residency Directors (CORD) membership in October 2014. The survey was a brief questionnaire, which inquired about fellowship, secondary board certification, gender, and length in a leadership position of each member of its residency leadership. We separated the responses to the survey into four different geographic regions. The geographic regions were defined by the same classification used by the National Resident Matching Program (NRMP). We defined residency leadership as program director (PD), associate PD and assistant PD. Residencies that did not complete the survey were then individually contacted to encourage completion. The survey was initially piloted for ease of use and understanding of the questions with a select few EM PDs. We obtained responses from 145 of the 164 Accrediting Council for Graduate Medical Education-accredited EM residencies (88%). The fellowship prevalence among PDs, associate PDs, and assistant PDs was 21.4%, 20.3%, and 24.9% respectively. The most common fellowship completed was a fellowship in toxicology. Secondary board certification among PDs, associate PDs, and assistant PDs was 9.7%, 4.8%, and 2.9% respectively. Eighty-two percent of PDs have at least five years in residency leadership. Seventy-six percent of PDs were male, and there was a near-even split of gender among associate PDs and assistant PDs. The Western region had the highest percentage of fellowship and or secondary board certification among all levels of residency leadership. There is a low prevalence of fellowship training and secondary board certification among EM residency leadership, with the most common being toxicology. Assistant PDs, the majority of whom had less than five years residency leadership experience, had the highest percentage of fellowship training. There may be a regional variation in the percentage of residency leadership completing postgraduate training.
Gastner, Michael T; Oborny, Beata; Zimmermann, D K; Pruessner, Gunnar
2009-07-01
A change in the environmental conditions across space-for example, altitude or latitude-can cause significant changes in the density of a vegetation type and, consequently, in spatial connectivity. We use spatially explicit simulations to study the transition from connected to fragmented vegetation. A static (gradient percolation) model is compared to dynamic (gradient contact process) models. Connectivity is characterized from the perspective of various species that use this vegetation type for habitat and differ in dispersal or migration range, that is, "step length" across the landscape. The boundary of connected vegetation delineated by a particular step length is termed the " hull edge." We found that for every step length and for every gradient, the hull edge is a fractal with dimension 7/4. The result is the same for different spatial models, suggesting that there are universal laws in ecotone geometry. To demonstrate that the model is applicable to real data, a hull edge of fractal dimension 7/4 is shown on a satellite image of a piñon-juniper woodland on a hillside. We propose to use the hull edge to define the boundary of a vegetation type unambiguously. This offers a new tool for detecting a shift of the boundary due to a climate change.
Pagel, Anna; Arieta, Alejandro Hernandez; Riener, Robert; Vallery, Heike
2016-10-01
Despite recent advances in leg prosthetics, transfemoral amputees still experience limitations in postural control and gait symmetry. It has been hypothesized that artificial sensory information might improve the integration of the prosthesis into the human sensory-motor control loops and, thus, reduce these limitations. In three transfemoral amputees, we investigated the effect of Electrotactile Moving Sensation for Sensory Augmentation (EMSSA) without training and present preliminary findings. Experimental conditions included standing with open/closed eyes on stable/unstable ground as well as treadmill walking. For standing conditions, spatiotemporal posturographic measures and sample entropy were derived from the center of pressure. For walking conditions, step length and stance duration were calculated. Conditions without feedback showed effects congruent with findings in the literature, e.g., asymmetric weight bearing and step length, and validated the collected data. During standing, with EMSSA a tendency to influence postural control in a negative way was found: Postural control was less effective and less efficient and the prosthetic leg was less involved. Sample entropy tended to decrease, suggesting that EMSSA demanded increased attention. During walking, with EMSSA no persistent positive effect was found. This contrasts the positive subjective assessment and the positive effect on one subject's step length.
Stochastic analysis of particle movement over a dune bed
Lee, Baum K.; Jobson, Harvey E.
1977-01-01
Stochastic models are available that can be used to predict the transport and dispersion of bed-material sediment particles in an alluvial channel. These models are based on the proposition that the movement of a single bed-material sediment particle consists of a series of steps of random length separated by rest periods of random duration and, therefore, application of the models requires a knowledge of the probability distributions of the step lengths, the rest periods, the elevation of particle deposition, and the elevation of particle erosion. The procedure was tested by determining distributions from bed profiles formed in a large laboratory flume with a coarse sand as the bed material. The elevation of particle deposition and the elevation of particle erosion can be considered to be identically distributed, and their distribution can be described by either a ' truncated Gaussian ' or a ' triangular ' density function. The conditional probability distribution of the rest period given the elevation of particle deposition closely followed the two-parameter gamma distribution. The conditional probability distribution of the step length given the elevation of particle erosion and the elevation of particle deposition also closely followed the two-parameter gamma density function. For a given flow, the scale and shape parameters describing the gamma probability distributions can be expressed as functions of bed-elevation. (Woodard-USGS)
Thijssen, Dick H; Paulus, Rebecca; van Uden, Caro J; Kooloos, Jan G; Hopman, Maria T
2007-02-01
To measure energy cost and gait analysis in persons with stroke with and without a newly developed orthosis. Immediate and long-term (3wk) intervention (before-after trial). University medical center. Volunteer sample of 27 persons with long-term (range, 0.6-19y) hemiparetic stroke. Three-week familiarization to the new walking aid. Energy cost (per distance walked), preferred walking speed (PWS), and step length. Energy cost was examined in all subjects while walking on a treadmill at 3 different velocities (PWS, PWS+30%, PWS-30%) during 3 different situations (without orthosis, with orthosis, after 3-wk orthosis familiarization). Spatiotemporal aspects of the gait pattern were examined using a 6-m instrumented walkway system. Using the orthosis immediately decreased energy cost in persons with stroke during walking at the PWS (P<.001) and significantly increased walking speed (P<.005) and step length (P<.001). After 3 weeks of familiarization to the orthosis, energy cost at the PWS and at PWS+30% showed further improvement in energy cost (P<.05). The newly developed orthosis immediately decreases energy cost and improves walking speed and step length in persons with long-term stroke. After only 3 weeks of orthosis familiarization, energy cost shows additional improvement.
Medicare's "Global" terrorism: where is the pay for performance?
Reed, R Lawrence; Luchette, Fred A; Esposito, Thomas J; Pyrz, Karen; Gamelli, Richard L
2008-02-01
Medicare and Medicaid Services (CMS) payment policies for surgical operations are based on a global package concept. CMS' physician fee schedule splits the global package into preoperative, intraoperative, and postoperative components of each procedure. We hypothesized that these global package component valuations were often lower than comparable evaluation and management (E&M) services and that billing for E&M services instead of the operation could often be more profitable. Our billing database and Trauma Registry were queried for the operative procedures and hospital lengths of stay for trauma patients during the past 5 years. Determinations of preoperative, intraoperative, and postoperative payments were calculated for 10-day and 90-day global packages, comparing them to CMS payments for comparable E&M codes. Of 90-day and 10-day Current Procedural Terminology codes, 88% and 100%, respectively, do not pay for the comprehensive history and physical that trauma patients usually receive, whereas 41% and 98%, respectively, do not even meet payment levels for a simple history and physical. Of 90-day global package procedures, 70% would have generated more revenue had comprehensive daily visits been billed instead of the operation ($3,057,500 vs. $1,658,058). For 10-day global package procedures, 56% would have generated more revenue with merely problem-focused daily visits instead of the operation ($161,855 vs. $156,318). Medicare's global surgical package underpays E&M services in trauma patients. In most cases, trauma surgeons would fare better by not billing for operations to receive higher reimbursement for E&M services that are considered "bundled" in the global package payment.
Bishop, P J; Clemente, C J; Weems, R E; Graham, D F; Lamas, L P; Hutchinson, J R; Rubenson, J; Wilson, R S; Hocknull, S A; Barrett, R S; Lloyd, D G
2017-07-01
How extinct, non-avian theropod dinosaurs locomoted is a subject of considerable interest, as is the manner in which it evolved on the line leading to birds. Fossil footprints provide the most direct evidence for answering these questions. In this study, step width-the mediolateral (transverse) distance between successive footfalls-was investigated with respect to speed (stride length) in non-avian theropod trackways of Late Triassic age. Comparable kinematic data were also collected for humans and 11 species of ground-dwelling birds. Permutation tests of the slope on a plot of step width against stride length showed that step width decreased continuously with increasing speed in the extinct theropods ( p < 0.001), as well as the five tallest bird species studied ( p < 0.01). Humans, by contrast, showed an abrupt decrease in step width at the walk-run transition. In the modern bipeds, these patterns reflect the use of either a discontinuous locomotor repertoire, characterized by distinct gaits (humans), or a continuous locomotor repertoire, where walking smoothly transitions into running (birds). The non-avian theropods are consequently inferred to have had a continuous locomotor repertoire, possibly including grounded running. Thus, features that characterize avian terrestrial locomotion had begun to evolve early in theropod history. © 2017 The Author(s).
36 CFR 1192.25 - Doors, steps and thresholds.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Contrast. All step edges, thresholds, and the boarding edge of ramps or lift platforms shall have a band of... lift or ramp surface, either light-on-dark or dark-on-light. (c) Door height. For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift...
36 CFR 1192.25 - Doors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Contrast. All step edges, thresholds, and the boarding edge of ramps or lift platforms shall have a band of... lift or ramp surface, either light-on-dark or dark-on-light. (c) Door height. For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift...
Development of Independent Locomotion in Children with a Severe Visual Impairment
ERIC Educational Resources Information Center
Hallemans, Ann; Ortibus, Els; Truijen, Steven; Meire, Francoise
2011-01-01
Locomotion of children and adults with a visual impairment (ages 1-44, n = 28) was compared to that of age-related individuals with normal vision (n = 60). Participants walked barefoot at preferred speed while their gait was recorded by a Vicon[R] system. Walking speed, heading angle, step frequency, stride length, step width, stance phase…
Pendular motion in the brachiation of captive Lagothrix and Ateles.
Turnquist, J E; Schmitt, D; Rose, M D; Cant, J G
1999-01-01
Pendular motion during brachiation of captive Lagothrix lagothricha lugens and Ateles fusciceps robustus was analyzed to demonstrate similarities, and differences, between these two closely related large bodied atelines. This is the first captive study of the kinematics of brachiation in Lagothrix. Videorecordings of one adult male of each species were made in a specially designed cage constructed at the DuMond Conservancy/Monkey Jungle, Miami, FL. Java software (Jandel Scientific Inc., San Rafael, CA) was used for frame-by-frame kinematic analysis of individual strides/steps. Results demonstrate that the sequence of hand and tail contacts differ significantly between the two species with Lagothrix using a new tail hold with every hand hold, while Ateles generally utilizes a new tail hold with only every other hand hold. Stride length and stride frequency, even after adjusting for limb length, also differ significantly between the two species. Lagothrix brachiation utilizes short, choppy strides with quick hand holds, while Ateles uses long, fluid strides with longer hand holds. During brachiation not only is Lagothrix's body significantly less horizontal than that of Ateles but also, within Ateles, there are significant differences between steps depending on tail use. Because of the unique nature of tail use in Ateles, many aspects of body positioning in Lagothrix more closely resemble Ateles steps without a simultaneous tail hold rather than those with one. Overall pendulum length in Lagothrix is shorter than in Ateles. Tail use in Ateles has a significant effect on maximum pendulum length during a step. Although neither species achieves the extreme pendulum effect and long period of free-flight of hylobatids in fast ricochetal brachiation, in captivity both consistently demonstrate effective brachiation with brief periods of free-flight and pendular motion. Morphological similarities between ateline brachiators and hylobatids are fewer and less pronounced in Lagothrix than in Ateles. This study demonstrates that Lagothrix brachiation is also less hylobatid-like than that of Ateles.
Arima, Hideyuki; Yamato, Yu; Hasegawa, Tomohiko; Kobayashi, Sho; Yoshida, Go; Yasuda, Tatsuya; Banno, Tomohiro; Oe, Shin; Mihara, Yuki; Togawa, Daisuke; Matsuyama, Yukihiro
2017-10-01
Longitudinal cohort. The present study aimed to document changes in posture and lower extremity kinematics during gait in patients with adult spinal deformity (ASD) after extensive corrective surgery. Standing radiographic parameters are typically used to evaluate patients with ASD. Previously, preoperative walking and standing posture discrepancy were reported in patients with ASD. We did not include comparison between before and after surgery. Therefore, we thought that pre- and postoperative evaluations for patients with ASD should include gait analysis. Thirty-nine patients with ASD (5 men, 34 women; mean age, 71.0 ± 6.1) who underwent posterior corrective fixation surgeries from the thoracic spine to the pelvis were included. A 4-m walk was recorded and analyzed. Sagittal balance while walking was calculated as the angle between the plumb line on the side and the line connecting the greater trochanter and pinna while walking (i.e., the gait-trunk tilt angle [GTA]). We measured maximum knee extension angle during one gait cycle, step length (cm), and walking speed (m/min). Radiographic parameters were also measured. The mean GTA and the mean maximum knee extension angle significantly improved from 13.4° to 6.4°, and -13.3° to -9.4°(P < 0.001 and P = 0.006), respectively. The mean step length improved from 40.4 to 43.1 cm (P = 0.049), but there was no significant change in walking speed (38.4 to 41.5 m/min, P = 0.105). Postoperative GTA, maximum knee extension angle and step length correlated with postoperative pelvic incidence minus lumbar lordosis (r = 0.324, P = 0.044; r = -0.317, P = 0.049; r = -0.416, P = 0.008, respectively). Our results suggest that postoperative posture, maximum knee extension angle, and step length during gait in patients with ASD improved corresponding to how much correction of the sagittal spinal deformity was achieved. 3.
Rey, Hebe Y; Faloci, Mirta; Medina, Ricardo; Dolce, Natalia; Mroginski, Luis; Engelmann, Florent
2009-01-01
A cryopreservation protocol using the encapsulation-dehydration procedure was established for shoot tips (2-3 mm in length) and meristems (0.3-0.5 mm) sampled from in vitro plantlets of diploid and triploid cytotypes of Arachis pintoi. The optimal protocol was the following: after dissection, explants were precultured for 24 h on establishment medium (EM), encapsulated in calcium alginate beads and pretreated in liquid EM medium with daily increasing sucrose concentration (0.5, 0.75, 1.0 M) and desiccated to 22-23 percent moisture content (fresh weight basis). Explants were frozen using slow cooling (1 C per min from 25C to -30C followed by direct immersion in liquid nitrogen), thawed rapidly and post-cultured in liquid EM medium enriched with daily decreasing sucrose concentrations (0.75, 0.50, 0.1 M). Explants were then transferred to solid EM medium in order to achieve shoot regeneration, then on Murashige and Skoog medium supplemented with 0.05 microM naphthalene acetic acid to induce rooting of shoots. With this procedure, 53 percent and 56 percent of cryopreserved shoot tips of the diploid and triploid cytotypes, respectively, survived and formed plants. However, only 16 percent of cryopreserved meristems of both cytotypes regenerated plants. Using ten isozyme systems and seven RAPD profiles, no modification induced by cryopreservation could be detected in plantlets regenerated from cryopreserved material.
NASA Astrophysics Data System (ADS)
Halder, Animesh; Saha, Baishakhi; Maity, Pabitra; Kumar, Gopinatha Suresh; Sinha, Deepak Kumar; Karmakar, Sanat
2018-02-01
We have studied the effect of composition and the phase state of phospholipid membranes on the emission spectrum, anisotropy and lifetime of a lipophilic fluorescence probe nile red. Fluorescence spectrum of nile red in membranes containing cholesterol has also been investigated in order to get insights into the influence of cholesterol on the phospholipid membranes. Maximum emission wavelength (λem) of nile red in the fluid phase of saturated and unsaturated phospholipids was found to differ by 10 nm. The λem was also found to be independent of chain length and charge of the membrane. However, the λem is strongly dependent on the temperature in the gel phase. The λem and rotational diffusion rate decrease, whereas the anisotropy and lifetime increase markedly with increasing cholesterol concentration for saturated phosoholipids, such as, dimyristoyl phosphatidylcholine (DMPC) in the liquid ordered phase. However, these spectroscopic properties do not alter significantly in case of unsaturated phospholipids, such as, dioleoyl phosphatidylcholine (DOPC) in liquid disordered phase. Interestingly, red edge excitation shift (REES) in the presence of lipid-cholesterol membranes is the direct consequences of change in rotational diffusion due to motional restriction of lipids in the presence of cholesterol. This study provides correlations between the membrane compositions and fluorescence spectral features which can be utilized in a wide range of biophysical fields as well the cell biology.
Amanullah, S. M.; Kim, D. H.; Lee, H. J.; Joo, Y. H.; Kim, S. B.; Kim, S. C.
2014-01-01
This study examined the effects of bacterial inoculants on chemical composition and fermentation indices of barley silage. Barley forage (Youngyang) was harvested at 24% dry matter (DM) and wilted to 47.9% DM. The wilted barley forage was chopped to 3–5 cm length and applied with no inoculant (CON), L. plantarum (1×1010 cfu/g, LP) or Effective Microorganisms (0.5×109 cfu/g, EM). Then the forages were ensiled in four replications for each treatment in 20 L mini silos and stored for 100 days. The contents of crude protein and ether extract were higher in CON silage ensiled for 100-d, while the contents of DM and crude ash were higher in EM silage (p<0.05). The contents of ADF, NDF and hemicellulose as well as the in vitro DM digestibility were not affected by microbial inoculation (p>0.05). The pH, ammonia-N concentration and lactate to acetate ratio were higher (p<0.05) in CON silage, while lactate concentrations were higher (p<0.05) in CON and LP silage. Acetate concentration and lactic acid bacteria was increased (p<0.05) by both inoculants (LP and EM), but propionate concentration and yeast was increased (p<0.05) by EM and LP, respectively. These results indicated that the fermentation quality of barley silage was improved by the application of bacterial inoculants. PMID:25049981
NASA Astrophysics Data System (ADS)
Meehan, T.; Osterberg, E. C.; Lewis, G.; Overly, T. B.; Hawley, R. L.; Bradford, J.; Marshall, H. P.
2016-12-01
To better predict the response of the Greenland Ice Sheet (GrIS) to future warming, leading edge Regional Climate Models (RCM) must be calibrated with in situ measurements of recent accumulation and melt. Mass balance estimates averaged across the entire Greenland Ice Sheet (GrIS) vary between models by more than 30 percent, and regional comparisons of mass balance reconstructions in Greenland vary by 100 percent or more. Greenland Traverse for Accumulation and Climate Studies (GreenTrACS) is a multi-year and multi-disciplinary 1700 km science traverse from Raven/Dye2 in SW Greenland, to Summit Station. Multi-offset radar measurements can provide high accuracy electromagnetic (EM) velocity estimates of the firn to within (+-) 0.002 to 0.003 m/ns. EM velocity, in turn, can be used to estimate bulk firn density. Using a mixing equation such as the CRIM Equation we use the measured EM velocity, along with the known EM velocity in air and ice, to estimate bulk density. During spring 2016, we used multi-channel 500MHz radar in a multi-offset configuration to survey more than 800 km from Raven towards summit. Preliminary radar-derived snow density estimates agree with density estimates from a firn core measurement ( 50 kg/m3), despite the lateral heterogeneity of the firn across the length of the antenna array (12 m).
Directivity analysis of meander-line-coil EMATs with a wholly analytical method.
Xie, Yuedong; Liu, Zenghua; Yin, Liyuan; Wu, Jiande; Deng, Peng; Yin, Wuliang
2017-01-01
This paper presents the simulation and experimental study of the radiation pattern of a meander-line-coil EMAT. A wholly analytical method, which involves the coupling of two models: an analytical EM model and an analytical UT model, has been developed to build EMAT models and analyse the Rayleigh waves' beam directivity. For a specific sensor configuration, Lorentz forces are calculated using the EM analytical method, which is adapted from the classic Deeds and Dodd solution. The calculated Lorentz force density are imported to an analytical ultrasonic model as driven point sources, which produce the Rayleigh waves within a layered medium. The effect of the length of the meander-line-coil on the Rayleigh waves' beam directivity is analysed quantitatively and verified experimentally. Copyright © 2016 Elsevier B.V. All rights reserved.
The precision of locomotor odometry in humans.
Durgin, Frank H; Akagi, Mikio; Gallistel, Charles R; Haiken, Woody
2009-03-01
Two experiments measured the human ability to reproduce locomotor distances of 4.6-100 m without visual feedback and compared distance production with time production. Subjects were not permitted to count steps. It was found that the precision of human odometry follows Weber's law that variability is proportional to distance. The coefficients of variation for distance production were much lower than those measured for time production for similar durations. Gait parameters recorded during the task (average step length and step frequency) were found to be even less variable suggesting that step integration could be the basis for non-visual human odometry.
Gait variability in community dwelling adults with Alzheimer disease.
Webster, Kate E; Merory, John R; Wittwer, Joanne E
2006-01-01
Studies have shown that measures of gait variability are associated with falling in older adults. However, few studies have measured gait variability in people with Alzheimer disease, despite the high incidence of falls in Alzheimer disease. The purpose of this study was to compare gait variability of community-dwelling older adults with Alzheimer disease and control subjects at various walking speeds. Ten subjects with mild-moderate Alzheimer disease and ten matched control subjects underwent gait analysis using an electronic walkway. Participants were required to walk at self-selected slow, preferred, and fast speeds. Stride length and step width variability were determined using the coefficient of variation. Results showed that stride length variability was significantly greater in the Alzheimer disease group compared with the control group at all speeds. In both groups, increases in walking speed were significantly correlated with decreases in stride length variability. Step width variability was significantly reduced in the Alzheimer disease group compared with the control group at slow speed only. In conclusion, there is an increase in stride length variability in Alzheimer disease at all walking speeds that may contribute to the increased incidence of falls in Alzheimer disease.
Bai, Neng; Li, Guifang
2014-02-24
The equalizer tap length requirement is investigated analytically and numerically for differential modal group delay (DMGD) compensated fiber link with weakly random mode coupling. Each span of the DMGD compensated link comprises multiple pairs of fibers which have opposite signs of DMGD. The result reveals that under weak random mode coupling, the required tap length of the equalizer is proportional to modal group delay of a single DMGD compensated pair, instead of the total modal group delay (MGD) of the entire link. By using small DMGD compensation step sizes, the required tap length (RTL) can be potentially reduced by 2 orders of magnitude.
The influence of gait speed on the stability of walking among the elderly.
Fan, Yifang; Li, Zhiyu; Han, Shuyan; Lv, Changsheng; Zhang, Bo
2016-06-01
Walking speed is a basic factor to consider when walking exercises are prescribed as part of a training programme. Although associations between walking speed, step length and falling risk have been identified, the relationship between spontaneous walking pattern and falling risk remains unclear. The present study, therefore, examined the stability of spontaneous walking at normal, fast and slow speed among elderly (67.5±3.23) and young (21.4±1.31) individuals. In all, 55 participants undertook a test that involved walking on a plantar pressure platform. Foot-ground contact data were used to calculate walking speed, step length, pressure impulse along the plantar-impulse principal axis and pressure record of time series along the plantar-impulse principal axis. A forward dynamics method was used to calculate acceleration, velocity and displacement of the centre of mass in the vertical direction. The results showed that when the elderly walked at different speeds, their average step length was smaller than that observed among the young (p=0.000), whereas their anterior/posterior variability and lateral variability had no significant difference. When walking was performed at normal or slow speed, no significant between-group difference in cadence was found. When walking at a fast speed, the elderly increased their stride length moderately and their cadence greatly (p=0.012). In summary, the present study found no correlation between fast walking speed and instability among the elderly, which indicates that healthy elderly individuals might safely perform fast-speed walking exercises. Copyright © 2016 Elsevier B.V. All rights reserved.
Influence of the random walk finite step on the first-passage probability
NASA Astrophysics Data System (ADS)
Klimenkova, Olga; Menshutin, Anton; Shchur, Lev
2018-01-01
A well known connection between first-passage probability of random walk and distribution of electrical potential described by Laplace equation is studied. We simulate random walk in the plane numerically as a discrete time process with fixed step length. We measure first-passage probability to touch the absorbing sphere of radius R in 2D. We found a regular deviation of the first-passage probability from the exact function, which we attribute to the finiteness of the random walk step.
Longo, Edoardo; Moretto, Alessandro; Formaggio, Fernando; Toniolo, Claudio
2011-10-01
Critical main-chain length for peptide helix formation in the crystal (solid) state and in organic solvents has been already reported. In this short communication, we describe our results aiming at assessing the aforementioned parameter in water solution. To this goal, we synthesized step-by-step by solution procedures a complete series of N-terminally acetylated, C-terminally methoxylated oligopeptides, characterized only by alternating Aib and Ala residues, from the dimer to the nonamer level. All these compounds were investigated by electronic circular dichroism in the far-UV region in water solution as a function of chemical structure, namely presence/absence of an ester moiety or a negative charge at the C-terminus, and temperature. We find that the critical main-chain lengths for 3(10)- and α-helices, although still formed to a limited extent, in aqueous solution are six and eight residues, respectively. © 2011 Wiley-Liss, Inc.
Medium- and Long-term Prediction of LOD Change by the Leap-step Autoregressive Model
NASA Astrophysics Data System (ADS)
Wang, Qijie
2015-08-01
The accuracy of medium- and long-term prediction of length of day (LOD) change base on combined least-square and autoregressive (LS+AR) deteriorates gradually. Leap-step autoregressive (LSAR) model can significantly reduce the edge effect of the observation sequence. Especially, LSAR model greatly improves the resolution of signals’ low-frequency components. Therefore, it can improve the efficiency of prediction. In this work, LSAR is used to forecast the LOD change. The LOD series from EOP 08 C04 provided by IERS is modeled by both the LSAR and AR models. The results of the two models are analyzed and compared. When the prediction length is between 10-30 days, the accuracy improvement is less than 10%. When the prediction length amounts to above 30 day, the accuracy improved obviously, with the maximum being around 19%. The results show that the LSAR model has higher prediction accuracy and stability in medium- and long-term prediction.
Critical motor number for fractional steps of cytoskeletal filaments in gliding assays.
Li, Xin; Lipowsky, Reinhard; Kierfeld, Jan
2012-01-01
In gliding assays, filaments are pulled by molecular motors that are immobilized on a solid surface. By varying the motor density on the surface, one can control the number N of motors that pull simultaneously on a single filament. Here, such gliding assays are studied theoretically using brownian (or Langevin) dynamics simulations and taking the local force balance between motors and filaments as well as the force-dependent velocity of the motors into account. We focus on the filament stepping dynamics and investigate how single motor properties such as stalk elasticity and step size determine the presence or absence of fractional steps of the filaments. We show that each gliding assay can be characterized by a critical motor number, N(c). Because of thermal fluctuations, fractional filament steps are only detectable as long as N < N(c). The corresponding fractional filament step size is l/N where l is the step size of a single motor. We first apply our computational approach to microtubules pulled by kinesin-1 motors. For elastic motor stalks that behave as linear springs with a zero rest length, the critical motor number is found to be N(c) = 4, and the corresponding distributions of the filament step sizes are in good agreement with the available experimental data. In general, the critical motor number N(c) depends on the elastic stalk properties and is reduced to N(c) = 3 for linear springs with a nonzero rest length. Furthermore, N(c) is shown to depend quadratically on the motor step size l. Therefore, gliding assays consisting of actin filaments and myosin-V are predicted to exhibit fractional filament steps up to motor number N = 31. Finally, we show that fractional filament steps are also detectable for a fixed average motor number
Developing 3D SEM in a broad biological context
Kremer, A; Lippens, S; Bartunkova, S; Asselbergh, B; Blanpain, C; Fendrych, M; Goossens, A; Holt, M; Janssens, S; Krols, M; Larsimont, J-C; Mc Guire, C; Nowack, MK; Saelens, X; Schertel, A; Schepens, B; Slezak, M; Timmerman, V; Theunis, C; Van Brempt, R; Visser, Y; GuÉRin, CJ
2015-01-01
When electron microscopy (EM) was introduced in the 1930s it gave scientists their first look into the nanoworld of cells. Over the last 80 years EM has vastly increased our understanding of the complex cellular structures that underlie the diverse functions that cells need to maintain life. One drawback that has been difficult to overcome was the inherent lack of volume information, mainly due to the limit on the thickness of sections that could be viewed in a transmission electron microscope (TEM). For many years scientists struggled to achieve three-dimensional (3D) EM using serial section reconstructions, TEM tomography, and scanning EM (SEM) techniques such as freeze-fracture. Although each technique yielded some special information, they required a significant amount of time and specialist expertise to obtain even a very small 3D EM dataset. Almost 20 years ago scientists began to exploit SEMs to image blocks of embedded tissues and perform serial sectioning of these tissues inside the SEM chamber. Using first focused ion beams (FIB) and subsequently robotic ultramicrotomes (serial block-face, SBF-SEM) microscopists were able to collect large volumes of 3D EM information at resolutions that could address many important biological questions, and do so in an efficient manner. We present here some examples of 3D EM taken from the many diverse specimens that have been imaged in our core facility. We propose that the next major step forward will be to efficiently correlate functional information obtained using light microscopy (LM) with 3D EM datasets to more completely investigate the important links between cell structures and their functions. Lay Description Life happens in three dimensions. For many years, first light, and then EM struggled to image the smallest parts of cells in 3D. With recent advances in technology and corresponding improvements in computing, scientists can now see the 3D world of the cell at the nanoscale. In this paper we present the results of high resolution 3D imaging in a number of diverse cells and tissues from multiple species. 3D reconstructions of cell structures often revealed them to be significantly more complex when compared to extrapolations made from 2D studies. Correlating functional 3D LM studies with 3D EM results opens up the possibility of making new strides in our understanding of how cell structure is connected to cell function. PMID:25623622
Wei, Guoke; Wang, Jinliang; Chen, Yu
2015-01-01
The enhancement factor (EF) of surface-enhanced Raman scattering (SERS) from two-dimensional (2D) hexagonal silver nanorod (AgNR) arrays were investigated in terms of electromagnetic (EM) mechanism by using the discrete dipole approximation (DDA) method. The dependence of EF on several parameters, i.e., structure, length, excitation wavelength, incident angle and polarization, and gap size has been investigated. "Hotspots" were found distributed in the gaps between adjacent nanorods. Simulations of AgNR arrays of different lengths revealed that increasing the rod length from 374 to 937 nm (aspect ratio from 2.0 to 5.0) generated more "hotspots" but not necessarily increased EF under both 514 and 532 nm excitation. A narrow lateral gap (in the incident plane) was found to result in strong EF, while the dependence of EF on the diagonal gap (out of the incident plane) showed an oscillating behavior. The EF of the array was highly dependent on the angle and polarization of the incident light. The structure of AgNR and the excitation wavelength were also found to affect the EF. The EF of random arrays was stronger than that of an ordered one with the same average gap of 21 nm, which could be explained by the exponential dependence of EF on the lateral gap size. Our results also suggested that absorption rather than extinction or scattering could be a good indicator of EM enhancement. It is expected that the understanding of the dependence of local field enhancement on the structure of the nanoarrays and incident excitations will shine light on the optimal design of efficient SERS substrates and improved performance.
Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos
2011-01-01
The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p < 0.004), step length (preoperative mean = 0.49, postoperative mean = 0.54; p < 0.01) , and walking velocity (preoperative mean = 0.78, preoperatively, postoperative mean = 0.99; p < 0.001). Decreases in stance duration percentage and knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.
Mohebbi, Maryam; Ghassemian, Hassan; Asl, Babak Mohammadzadeh
2011-05-01
This paper aims to propose an effective paroxysmal atrial fibrillation (PAF) predictor which is based on the analysis of the heart rate variability (HRV) signal. Predicting the onset of PAF, based on non-invasive techniques, is clinically important and can be invaluable in order to avoid useless therapeutic interventions and to minimize the risks for the patients. This method consists of four steps: Preprocessing, feature extraction, feature reduction, and classification. In the first step, the QRS complexes are detected from the electrocardiogram (ECG) signal and then the HRV signal is extracted. In the next step, the recurrence plot (RP) of HRV signal is obtained and six features are extracted to characterize the basic patterns of the RP. These features consist of length of longest diagonal segments, average length of the diagonal lines, entropy, trapping time, length of longest vertical line, and recurrence trend. In the third step, these features are reduced to three features by the linear discriminant analysis (LDA) technique. Using LDA not only reduces the number of the input features, but also increases the classification accuracy by selecting the most discriminating features. Finally, a support vector machine-based classifier is used to classify the HRV signals. The performance of the proposed method in prediction of PAF episodes was evaluated using the Atrial Fibrillation Prediction Database which consists of both 30-minutes ECG recordings end just prior to the onset of PAF and segments at least 45 min distant from any PAF events. The obtained sensitivity, specificity, and positive predictivity were 96.55%, 100%, and 100%, respectively.
McAllister, Chris T.; Duszynski, Donald W.; Austin, Christopher C.; Fisher, Robert N.
2017-01-01
Between September and November 1991, 54 adult skinks from 15 species were collected by hand or blowpipe from several localities on Rarotonga, Cook Islands, Ovalau Island, Fiji, and Papua New Guinea (PNG), and their feces were examined for coccidians. Species included 5 seaside skinks (Emoia atrocostata), 1 Pacific blue-tailed skink (Emoia caeroleocauda), 2 Fiji slender treeskinks (Emoia concolor), 15 white-bellied copper-striped skinks (Emoia cyanura), 1 Bulolo River forest skink (Emoia guttata), 6 dark-bellied copper-striped skinks (Emoia impar), 5 Papua five-striped skinks (Emoia jakati), 2 Papua slender treeskinks (Emoia kordoana), 3 Papua robust treeskinks (Emoia longicauda), 1 brown-backed forest skink (Emoia loveridgei), 3 Papua black-sided skinks (Emoia pallidiceps), 2 Papua white-spotted skinks (Emoia physicae), 2 Papua yellow-head skinks (Emoia popei), 1 Papua brown forest skink (Emoia submetallica), and 5 Fiji barred treeskinks (Emoia trossula) Species of Eimeria (Ei.) were detected from these Emoia (Em.) spp. and are described here as new. Oocysts of Eimeria iovai n. sp. from Em. pallidiceps from PNG were ellipsoidal with a bilayered wall (L × W) 26.5 × 18.1 μm, with a length/width ratio (L/W) of 1.1. Both micropyle and oocyst residuum were absent, but a fragmented polar granule was present. This eimerian also was found in Em. atrocostata from PNG. Oocysts of Eimeria kirkpatricki n. sp. from Em. atrocostata from PNG were ellipsoidal with a bilayered wall, 18.6 × 13.5 μm, L/W 1.4. A micropyle and oocyst residuum were absent, but a fragmented polar granule was present. This eimerian was also shared by Em. cyanura from the Cook Islands and Fiji, Em. imparfrom the Cook Islands, Em. loveridgei from PNG, Em. pallidicepsfrom PNG, Em. popei from PNG, and Em. submetallica from PNG. Oocysts of Eimeria stevejayuptoni n. sp. from Em. longicaudawere subspheroidal to ellipsoidal with a bilayered wall, 18.7 × 16.6 μm, L/W 1.1. A micropyle and oocyst residuum were absent, but a fragmented polar granule was present. Oocysts of Eimeria emoia n. sp. from Em. longicauda from PNG were cylindroidal with a bilayered wall, 29.2 × 15.7 μm, L/W 1.9. A micropyle and oocyst residuum were absent, but a polar granule was present. These are the first eimerians reported from Emoia spp. and they add to our growing knowledge of the coccidian fauna of scincid lizards of the South Pacific.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jihoon; Um, Evan; Moridis, George
2014-12-01
We investigate fracture propagation induced by hydraulic fracturing with water injection, using numerical simulation. For rigorous, full 3D modeling, we employ a numerical method that can model failure resulting from tensile and shear stresses, dynamic nonlinear permeability, leak-off in all directions, and thermo-poro-mechanical effects with the double porosity approach. Our numerical results indicate that fracture propagation is not the same as propagation of the water front, because fracturing is governed by geomechanics, whereas water saturation is determined by fluid flow. At early times, the water saturation front is almost identical to the fracture tip, suggesting that the fracture is mostlymore » filled with injected water. However, at late times, advance of the water front is retarded compared to fracture propagation, yielding a significant gap between the water front and the fracture top, which is filled with reservoir gas. We also find considerable leak-off of water to the reservoir. The inconsistency between the fracture volume and the volume of injected water cannot properly calculate the fracture length, when it is estimated based on the simple assumption that the fracture is fully saturated with injected water. As an example of flow-geomechanical responses, we identify pressure fluctuation under constant water injection, because hydraulic fracturing is itself a set of many failure processes, in which pressure consistently drops when failure occurs, but fluctuation decreases as the fracture length grows. We also study application of electromagnetic (EM) geophysical methods, because these methods are highly sensitive to changes in porosity and pore-fluid properties due to water injection into gas reservoirs. Employing a 3D finite-element EM geophysical simulator, we evaluate the sensitivity of the crosswell EM method for monitoring fluid movements in shaly reservoirs. For this sensitivity evaluation, reservoir models are generated through the coupled flow-geomechanical simulator and are transformed via a rock-physics model into electrical conductivity models. It is shown that anomalous conductivity distribution in the resulting models is closely related to injected water saturation, but not closely related to newly created unsaturated fractures. Our numerical modeling experiments demonstrate that the crosswell EM method can be highly sensitive to conductivity changes that directly indicate the migration pathways of the injected fluid. Accordingly, the EM method can serve as an effective monitoring tool for distribution of injected fluids (i.e., migration pathways) during hydraulic fracturing operations« less
Monte Carlo Sampling in Fractal Landscapes
NASA Astrophysics Data System (ADS)
Leitão, Jorge C.; Lopes, J. M. Viana Parente; Altmann, Eduardo G.
2013-05-01
We design a random walk to explore fractal landscapes such as those describing chaotic transients in dynamical systems. We show that the random walk moves efficiently only when its step length depends on the height of the landscape via the largest Lyapunov exponent of the chaotic system. We propose a generalization of the Wang-Landau algorithm which constructs not only the density of states (transient time distribution) but also the correct step length. As a result, we obtain a flat-histogram Monte Carlo method which samples fractal landscapes in polynomial time, a dramatic improvement over the exponential scaling of traditional uniform-sampling methods. Our results are not limited by the dimensionality of the landscape and are confirmed numerically in chaotic systems with up to 30 dimensions.
New method for calculating the coupling coefficient in graded index optical fibers
NASA Astrophysics Data System (ADS)
Savović, Svetislav; Djordjevich, Alexandar
2018-05-01
A simple method is proposed for determining the mode coupling coefficient D in graded index multimode optical fibers. It only requires observation of the output modal power distribution P(m, z) for one fiber length z as the Gaussian launching modal power distribution changes, with the Gaussian input light distribution centered along the graded index optical fiber axis (θ0 = 0) without radial offset (r0 = 0). A similar method we previously proposed for calculating the coupling coefficient D in a step-index multimode optical fibers where the output angular power distributions P(θ, z) for one fiber length z with the Gaussian input light distribution launched centrally along the step-index optical fiber axis (θ0 = 0) is needed to be known.
The Pearson walk with shrinking steps in two dimensions
NASA Astrophysics Data System (ADS)
Serino, C. A.; Redner, S.
2010-01-01
We study the shrinking Pearson random walk in two dimensions and greater, in which the direction of the Nth step is random and its length equals λN-1, with λ<1. As λ increases past a critical value λc, the endpoint distribution in two dimensions, P(r), changes from having a global maximum away from the origin to being peaked at the origin. The probability distribution for a single coordinate, P(x), undergoes a similar transition, but exhibits multiple maxima on a fine length scale for λ close to λc. We numerically determine P(r) and P(x) by applying a known algorithm that accurately inverts the exact Bessel function product form of the Fourier transform for the probability distributions.
Neck linker length determines the degree of processivity in kinesin-1 and kinesin-2 motors.
Shastry, Shankar; Hancock, William O
2010-05-25
Defining the mechanical and biochemical determinates of kinesin processivity is important for understanding how diverse kinesins are tuned for specific cellular functions. Because transmission of mechanical forces through the 14-18 amino acid neck linker domain underlies coordinated stepping, we investigated the role of neck linker length, charge, and structure in kinesin-1 and kinesin-2 motor behavior. For optimum comparison with kinesin-1, the KIF3A head and neck linker of kinesin-2 were fused to the kinesin-1 neck coil and rod. Extending the 14-residue kinesin-1 neck linker reduced processivity, and shortening the 17-residue kinesin-2 neck linker enhanced processivity. When a proline in the kinesin-2 neck linker was replaced, kinesin-1 and kinesin-2 run lengths scaled identically with neck linker length, despite moving at different speeds. In low-ionic-strength buffer, charge had a dominant effect on motor processivity, which resolves ongoing controversy regarding the effect of neck linker length on kinesin processivity. From stochastic simulations, the results are best explained by neck linker extension slowing strain-dependent detachment of the rear head along with diminishing strain-dependent inhibition of ATP binding. These results help delineate how interhead strain maximizes stepping and suggest that less processive kinesins are tuned to coordinate with other motors differently than the maximally processive kinesin-1. Copyright 2010 Elsevier Ltd. All rights reserved.
Czaplik, M; Bergrath, S; Rossaint, R; Thelen, S; Brodziak, T; Valentin, B; Hirsch, F; Beckers, S K; Brokmann, J C
2014-01-01
Demographic change, rising co-morbidity and an increasing number of emergencies are the main challenges that emergency medical services (EMS) in several countries worldwide are facing. In order to improve quality in EMS, highly trained personnel and well-equipped ambulances are essential. However several studies have shown a deficiency in qualified EMS physicians. Telemedicine emerges as a complementary system in EMS that may provide expertise and improve quality of medical treatment on the scene. Hence our aim is to develop and test a specific teleconsultation system. During the development process several use cases were defined and technically specified by medical experts and engineers in the areas of: system administration, start-up of EMS assistance systems, audio communication, data transfer, routine tele-EMS physician activities and research capabilities. Upon completion, technical field tests were performed under realistic conditions to test system properties such as robustness, feasibility and usability, providing end-to-end measurements. Six ambulances were equipped with telemedical facilities based on the results of the requirement analysis and 55 scenarios were tested under realistic conditions in one month. The results indicate that the developed system performed well in terms of usability and robustness. The major challenges were, as expected, mobile communication and data network availability. Third generation networks were only available in 76.4% of the cases. Although 3G (third generation), such as Universal Mobile Telecommunications System (UMTS), provides beneficial conditions for higher bandwidth, system performance for most features was also acceptable under adequate 2G (second generation) test conditions. An innovative concept for the use of telemedicine for medical consultations in EMS was developed. Organisational and technical aspects were considered and practical requirements specified. Since technical feasibility was demonstrated in these technical field tests, the next step would be to prove medical usefulness and technical robustness under real conditions in a clinical trial.
Field EMS Quality, Innovation, and Cost Effectiveness Improvements Act of 2011
Rep. Walz, Timothy J. [D-MN-1
2011-10-07
House - 10/12/2011 Referred for a period ending not later than October 12, 2011, (or for a later time if the Chairman so designates) to the Subcommittee on Health, in each case for consideration of such provisions as fall within the jurisdiction of the subcommittee concerned. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Lin, Cheng-Chieh; Creath, Robert A; Rogers, Mark W
2016-01-01
In people with Parkinson disease (PD), difficulties with initiating stepping may be related to impairments of anticipatory postural adjustments (APAs). Increased variability in step length and step time has been observed in gait initiation in individuals with PD. In this study, we investigated whether the ability to generate consistent APAs during gait initiation is compromised in these individuals. Fifteen subjects with PD and 8 healthy control subjects were instructed to take rapid forward steps after a verbal cue. The changes in vertical force and ankle marker position were recorded via force platforms and a 3-dimensional motion capture system, respectively. Means, standard deviations, and coefficients of variation of both timing and magnitude of vertical force, as well as stepping variables, were calculated. During the postural phase of gait initiation the interval was longer and the force modulation was smaller in subjects with PD. Both the variability of timing and force modulation were larger in subjects with PD. Individuals with PD also had a longer time to complete the first step, but no significant differences were found for the variability of step time, length, and speed between groups. The increased variability of APAs during gait initiation in subjects with PD could affect posture-locomotion coupling, and lead to start hesitation, and even falls. Future studies are needed to investigate the effect of rehabilitation interventions on the variability of APAs during gait initiation in individuals with PD.Video abstract available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A119).
Index Fund Selections with GAs and Classifications Based on Turnover
NASA Astrophysics Data System (ADS)
Orito, Yukiko; Motoyama, Takaaki; Yamazaki, Genji
It is well known that index fund selections are important for the risk hedge of investment in a stock market. The`selection’means that for`stock index futures’, n companies of all ones in the market are selected. For index fund selections, Orito et al.(6) proposed a method consisting of the following two steps : Step 1 is to select N companies in the market with a heuristic rule based on the coefficient of determination between the return rate of each company in the market and the increasing rate of the stock price index. Step 2 is to construct a group of n companies by applying genetic algorithms to the set of N companies. We note that the rule of Step 1 is not unique. The accuracy of the results using their method depends on the length of time data (price data) in the experiments. The main purpose of this paper is to introduce a more`effective rule’for Step 1. The rule is based on turnover. The method consisting of Step 1 based on turnover and Step 2 is examined with numerical experiments for the 1st Section of Tokyo Stock Exchange. The results show that with our method, it is possible to construct the more effective index fund than the results of Orito et al.(6). The accuracy of the results using our method depends little on the length of time data (turnover data). The method especially works well when the increasing rate of the stock price index over a period can be viewed as a linear time series data.
Transitioning to a narrow path: the impact of fear of falling in older adults.
Dunlap, Pamela; Perera, Subashan; VanSwearingen, Jessie M; Wert, David; Brach, Jennifer S
2012-01-01
Everyday ambulation requires navigation of variable terrain, transitions from wide to narrow pathways, and avoiding obstacles. While the effect of age on the transition to a narrow path has been examined briefly, little is known about the impact of fear of falling on gait during the transition to a narrow path. The purpose was to examine the effect of age and fear of falling on gait during transition to a narrow path. In 31 young, mean age=25.3 years, and 30 older adults, mean age=79.6 years, step length, step time, step width and gait speed were examined during usual and transition to narrow pathway using an instrumented walkway. During the transition to narrow walk condition, fearful older adults compared to young had a wider step width (0.06 m vs 0.04 m) prior to the narrow path and took shorter steps (0.53 m vs 0.72 m; p<0.001). Compared to non-fearful older adults, fearful older adults walked slower and took shorter steps during narrow path walking (gait speed: 1.1m/s vs 0.82 m/s; p=0.01; step length: 0.60 m vs 0.47 m; p=0.03). In young and non-fearful older adults narrow path gait was similar to usual gait. Whereas older adults who were fearful, walked slower (0.82 m/s vs 0.91 m/s; p=0.001) and took shorter steps (0.44 m vs 0.53 m; p=0.004) during narrow path walking compared to usual walking. Changes in gait characteristics with transitioning to a narrow pathway were greater for fear of falling than for age. Copyright © 2011 Elsevier B.V. All rights reserved.
Stepping over obstacles: anticipatory modifications in children with and without Down syndrome.
Virji-Babul, Naznin; Brown, Michelle
2004-12-01
The purpose of this study was to explore the mechanism of anticipatory control of gait in relation to the perception of an obstacle. Typically developing (TD) children (4-7 years of age) and children with Down syndrome (5-6 years of age) walked and stepped over obstacles of two different heights-a "subtle" obstacle that was placed at a very low distance from the floor (1% of total body height) and an "obvious" obstacle that was placed at a much higher distance from the floor (15% of total body height). Spatial and temporal measures of the gait cycle were analyzed. TD children showed increased variability in pre-obstacle step lengths only in response to the higher obstacle. Children with DS showed a decrease in variability in response to the higher obstacle and marked qualitative changes in their gait cycle. Both groups of children were able to scale toe clearance with obstacle height. These results show that TD young children can make task-specific anticipatory adjustments by modulating step length and toe clearance. Children with DS show appropriate scaling of toe clearance and are beginning to show the emergence of anticipatory responses under specific environmental conditions.
Redox and Chemical Activities of the Hemes in the Sulfur Oxidation Pathway Enzyme SoxAX*
Bradley, Justin M.; Marritt, Sophie J.; Kihlken, Margaret A.; Haynes, Kate; Hemmings, Andrew M.; Berks, Ben C.; Cheesman, Myles R.; Butt, Julea N.
2012-01-01
SoxAX enzymes couple disulfide bond formation to the reduction of cytochrome c in the first step of the phylogenetically widespread Sox microbial sulfur oxidation pathway. Rhodovulum sulfidophilum SoxAX contains three hemes. An electrochemical cell compatible with magnetic circular dichroism at near infrared wavelengths has been developed to resolve redox and chemical properties of the SoxAX hemes. In combination with potentiometric titrations monitored by electronic absorbance and EPR, this method defines midpoint potentials (Em) at pH 7.0 of approximately +210, −340, and −400 mV for the His/Met, His/Cys−, and active site His/CysS−-ligated heme, respectively. Exposing SoxAX to S2O42−, a substrate analog with Em ∼−450 mV, but not Eu(II) complexed with diethylene triamine pentaacetic acid (Em ∼−1140 mV), allows cyanide to displace the cysteine persulfide (CysS−) ligand to the active site heme. This provides the first evidence for the dissociation of CysS− that has been proposed as a key event in SoxAX catalysis. PMID:23060437
Kar, Anirban; Jones, Nathan; Arat, N Özlem; Fishel, Richard; Griffith, Jack
2018-04-19
Conformations adopted by long stretches of single stranded DNA (ssDNA) are of central interest in understanding the architecture of replication forks, R loops, and other structures generated during DNA metabolism in vivo. This is particularly so if the ssDNA consists of short nucleotide repeats. Such studies have been hampered by the lack of defined substrates greater than ~150 nt, and the absence of high-resolution biophysical approaches. Here we describe the generation of very long ssDNA consisting of the mammalian telomeric repeat (5'-TTAGGG-3')n as well as the interrogation of its structure by electron microscopy (EM) and single molecule magnetic tweezers (smMT). This repeat is of particular interest as it contains a run of 3 contiguous guanine residues capable of forming G quartets as ssDNA. Fluorescent-dye exclusion assays confirmed that this G-strand ssDNA forms ubiquitous G-quadruplex folds. EM revealed thick bead-like filaments that condensed the DNA ~12 fold. The bead-like structures were 5 nm and 8 nm in diameter and linked by thin filaments. The G-strand ssDNA displayed initial stability to smMT force extension that ultimately released in steps that were multiples ~28 nm at forces between 6-12 pN; well below the >20 pN required to unravel G-quadruplexes. Most smMT steps were consistent with the disruption of the beads seen by EM. Binding by RAD51 distinctively altered the force extension properties of the G-strand ssDNA, suggesting a stochastic G-quadruplex-dependent condensation model that is discussed. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.
NASA Astrophysics Data System (ADS)
Viganotti, Matteo; Jackson, Ruth; Krahn, Hartmut; Dyer, Mark
2013-05-01
Earthen flood defence embankments are linear structures, raised above the flood plain, that are commonly used as flood defences in rural settings; these are often relatively old structures constructed using locally garnered material and of which little is known in terms of design and construction. Alarmingly, it is generally reported that a number of urban developments have expanded to previously rural areas; hence, acquiring knowledge about the flood defences protecting these areas has risen significantly in the agendas of basin and asset managers. This paper focusses, by reporting two case studies, on electromagnetic induction (EMI) methods that would efficiently complement routine visual inspections and would represent a first step to more detailed investigations. Evaluation of the results is presented by comparison with ERT profiles and intrusive investigation data. The EM data, acquired using a GEM-2 apparatus for frequency sounding and an EM-31 apparatus for geometrical sounding, has been handled using the prototype eGMS software tool, being developed by the eGMS international research consortium; the depth sounding data interpretation was assisted by 1D inversions obtained with the EM1DFM software developed by the University of British Columbia. Although both sounding methods showed some limitations, the models obtained were consistent with ERT models and the techniques were useful screening methods for the identification of areas of interest, such as material interfaces or potential seepage areas, within the embankment structure: 1D modelling improved the rapid assessment of earthen flood defence embankments in an estuarine environment; evidence that EMI sounding could play an important role as a monitoring tool or as a first step towards more detailed investigations.
Our Human Journey to Mars - The Next Steps
NASA Technical Reports Server (NTRS)
Singer, Jody
2016-01-01
The United States National Aeronautics and Space Administration (NASA) will be launching the super-heavy-lift Space Launch System (SLS) by the end of the decade. This launch marks the next steps of human exploration of Mars and continues the journey that began over 50 years ago with Mariner and most recently ExoMars. SLS is the only rocket with the power capable of sending humans to deep space and the large systems necessary for human exploration all the way to Mars. Exploration Mission (EM)-1 will be the first integrated flight of the SLS rocket and Orion spacecraft - journeying farther into space than Apollo. NASA will also expand the science and exploration capability of SLS by deploying thirteen small satellites into deep space for the first time. These small satellites, created through partnerships with small businesses, Universities and international partners, will carry out various scientific missions to better understand our universe and the challenges of living and working in deep space. SLS EM-1 will provide the framework and serve as a test flight, not only for vehicle systems, but also for payload accommodations, ground processing and on-orbit operations. The results of this mission will validate capabilities for sending explorers to Mars and create the opportunity to pioneer solutions to challenges to deep space exploration. SLS's versatile design will evolve for future exploration needs and accommodate bigger payloads, such as large aperture telescopes for scientific research or manned human deep space exploration missions to Mars. The achievement of EM-1 will demonstrate NASA's commitment and capability to extend human existence to deep space and inspire the world to pursue greatness in the exploration of our universe.
Gene Hern, H; Wills, Charlotte; Alter, Harrison; Bowman, Steven H; Katz, Eric; Shayne, Philip; Vahidnia, Farnaz
2009-12-01
The residency review committee for emergency medicine (EM) requires residents to have greater than 70% attendance of educational conferences during residency training, but it is unknown whether attendance improves clinical competence or scores on the American Board of Emergency Medicine (ABEM) in-training examination (ITE). This study examined the relationship between conference attendance and ITE scores. The hypothesis was that greater attendance would correlate to a higher examination score. This was a multi-center retrospective cohort study using conference attendance data and examination results from residents in four large county EM residency training programs. Longitudinal multi-level models, adjusting for training site, U.S. Medical Licensing Examination (USMLE) Step 1 score, and sex were used to explore the relationship between conference attendance and in-training examination scores according to year of training. Each year of training was studied, as well as the overall effect of mean attendance as it related to examination score. Four training sites reported data on 405 residents during 2002 to 2008; 386 residents had sufficient data to analyze. In the multi-level longitudinal models, attendance at conference was not a significant predictor of in-training percentile score (coefficient = 0.005, 95% confidence interval [CI] = -0.053 to 0.063, p = 0.87). Score on the USMLE Step 1 examination was a strong predictor of ITE score (coefficient = 0.186, 95% CI = 0.155 to 0.217; p < 0.001), as was female sex (coefficient = 2.117, 95% CI = 0.987 to 3.25; p < 0.001). Greater conference attendance does not correlate with performance on an individual's ITE scores. Conference attendance may represent an important part of EM residency training but perhaps not of ITE performance. (c) 2009 by the Society for Academic Emergency Medicine.
Polyphenol fatty acid esters as serine protease inhibitors: a quantum-chemical QSAR analysis.
Viskupicova, Jana; Danihelova, Martina; Majekova, Magdalena; Liptaj, Tibor; Sturdik, Ernest
2012-12-01
We investigated the ability of polyphenol fatty acid esters to inhibit the activity of serine proteases trypsin, thrombin, elastase and urokinase. Potent protease inhibition in micromolar range was displayed by rutin and rutin derivatives esterified with medium and long chain, mono- and polyunsaturated fatty acids (1e-m), followed by phloridzin and esculin esters with medium and long fatty acid chain length (2a-d, 3a-d), while unmodified compounds showed only little or no effect. QSAR study of the compounds tested provided the most significant parameters for individual inhibition activities, i.e. number of hydrogen bond donors for urokinase, molecular volume for thrombin, and solvation energy for elastase. According to the statistical analysis, the action of elastase inhibitors is opposed to those of urokinase and thrombin. Cluster analysis showed two groups of compounds: original polyphenols together with rutin esters with short fatty acid chain length and rutin esters with long fatty acid chain length.
Conformational states of the full-length glucagon receptor
Yang, Linlin; Yang, Dehua; de Graaf, Chris; Moeller, Arne; West, Graham M.; Dharmarajan, Venkatasubramanian; Wang, Chong; Siu, Fai Y.; Song, Gaojie; Reedtz-Runge, Steffen; Pascal, Bruce D.; Wu, Beili; Potter, Clinton S.; Zhou, Hu; Griffin, Patrick R.; Carragher, Bridget; Yang, Huaiyu; Wang, Ming-Wei; Stevens, Raymond C.; Jiang, Hualiang
2015-01-01
Class B G protein-coupled receptors are composed of an extracellular domain (ECD) and a seven-transmembrane (7TM) domain, and their signalling is regulated by peptide hormones. Using a hybrid structural biology approach together with the ECD and 7TM domain crystal structures of the glucagon receptor (GCGR), we examine the relationship between full-length receptor conformation and peptide ligand binding. Molecular dynamics (MD) and disulfide crosslinking studies suggest that apo-GCGR can adopt both an open and closed conformation associated with extensive contacts between the ECD and 7TM domain. The electron microscopy (EM) map of the full-length GCGR shows how a monoclonal antibody stabilizes the ECD and 7TM domain in an elongated conformation. Hydrogen/deuterium exchange (HDX) studies and MD simulations indicate that an open conformation is also stabilized by peptide ligand binding. The combined studies reveal the open/closed states of GCGR and suggest that glucagon binds to GCGR by a conformational selection mechanism. PMID:26227798
1988-01-01
The stereocilia on each hair cell are arranged into rows of ascending height, resulting in what we refer to as a "staircase-like" profile. At the proximal end of the cochlea the length of the tallest row of stereocilia in the staircase is 1.5 micron, with the shortest row only 0.3 micron. As one proceeds towards the distal end of the cochlea the length of the stereocilia progressively increases so that at the extreme distal end the length of the tallest row of the staircase is 5.5 micron and the shortest row is 2 micron. During development hair cells form their staircases in four phases of growth separated from each other by developmental time. First, stereocilia sprout from the apical surfaces of the hair cells (8-10-d embryos). Second (10-12-d embryos), what will be the longest row of the staircase begins to elongate. As the embryo gets older successive rows of stereocilia initiate elongation. Thus the staircase is set up by the sequential initiation of elongation of stereociliary rows located at increased distances from the row that began elongation. Third (12-17-d embryos), all the stereocilia in the newly formed staircase elongate until those located on the first step of the staircase have reached the prescribed length. In the final phase (17-d embryos to hatchlings) there is a progressive cessation of elongation beginning with the shortest step and followed by taller and taller rows with the tallest step stopping last. Thus, to obtain a pattern of stereocilia in rows of increasing height what transpires are progressive go signals followed by a period when all the stereocilia grow and ending with progressive stop signals. We discuss how such a sequence could be controlled. PMID:3339095
Parameter Estimation of Multiple Frequency-Hopping Signals with Two Sensors
Pan, Jin; Ma, Boyuan
2018-01-01
This paper essentially focuses on parameter estimation of multiple wideband emitting sources with time-varying frequencies, such as two-dimensional (2-D) direction of arrival (DOA) and signal sorting, with a low-cost circular synthetic array (CSA) consisting of only two rotating sensors. Our basic idea is to decompose the received data, which is a superimposition of phase measurements from multiple sources into separated groups and separately estimate the DOA associated with each source. Motivated by joint parameter estimation, we propose to adopt the expectation maximization (EM) algorithm in this paper; our method involves two steps, namely, the expectation-step (E-step) and the maximization (M-step). In the E-step, the correspondence of each signal with its emitting source is found. Then, in the M-step, the maximum-likelihood (ML) estimates of the DOA parameters are obtained. These two steps are iteratively and alternatively executed to jointly determine the DOAs and sort multiple signals. Closed-form DOA estimation formulae are developed by ML estimation based on phase data, which also realize an optimal estimation. Directional ambiguity is also addressed by another ML estimation method based on received complex responses. The Cramer-Rao lower bound is derived for understanding the estimation accuracy and performance comparison. The verification of the proposed method is demonstrated with simulations. PMID:29617323
Offer, Gerald; Ranatunga, K W
2015-01-01
The isometric tetanic tension of skeletal muscle increases with temperature because attached crossbridge states bearing a relatively low force convert to those bearing a higher force. It was previously proposed that the tension-generating step(s) in the crossbridge cycle was highly endothermic and was therefore itself directly targeted by changes in temperature. However, this did not explain why a rapid rise in temperature (a temperature jump) caused a much slower rate of rise of tension than a rapid length step. This led to suggestions that the step targeted by a temperature rise is not the tension-generating step but is an extra step in the attached pathway of the crossbridge cycle, perhaps located on a parallel pathway. This enigma has been a major obstacle to a full understanding of the operation of the crossbridge cycle. We have now used a previously developed mechano-kinetic model of the crossbridge cycle in frog muscle to simulate the temperature dependence of isometric tension and shortening velocity. We allowed all five steps in the cycle to be temperature-sensitive. Models with different starting combinations of enthalpy changes and activation enthalpies for the five steps were refined by downhill simplex runs and scored by their ability to fit experimental data on the temperature dependence of isometric tension and the relationship between force and shortening velocity in frog muscle. We conclude that the first tension-generating step may be weakly endothermic and that the rise of tension with temperature is largely driven by the preceding two strongly endothermic steps of ATP hydrolysis and attachment of M.ADP.Pi to actin. The refined model gave a reasonable fit to the available experimental data and after a temperature jump the overall rate of tension rise was much slower than after a length step as observed experimentally. The findings aid our understanding of the crossbridge cycle by showing that it may not be necessary to include an additional temperature-sensitive step. PMID:25564737
Kanavarioti, Anastassia; Greenman, Kevin L.; Hamalainen, Mark; Jain, Aakriti; Johns, Adam M.; Melville, Chris R.; Kemmish, Kent; Andregg, William
2014-01-01
With the recent advances in electron microscopy (EM), computation, and nanofabrication, the original idea of reading DNA sequence directly from an image can now be tested. One approach is to develop heavy atom labels that can provide the contrast required for EM imaging. While evaluating tentative labels for the respective nucleobases in synthetic oligodeoxynucleotides (oligos), we developed a streamlined capillary electrophoresis (CE) protocol to assess the label stability, reactivity, and selectivity. We report our protocol using osmium tetroxide 2,2′-bipyridine (Osbipy) as a thymidine (T) specific label. The observed rates show that the labeling process is kinetically independent of both the oligo length, and the base composition. The conditions, i.e. temperature, optimal Osbipy concentration, and molar ratio of reagents, to promote 100% conversion of the starting oligo to labeled product were established. Hence the optimized conditions developed with the oligos could be leveraged to allow osmylation of effectively all Ts in single-stranded (ss) DNA, while achieving minimal mislabeling. In addition, the approach and methods employed here may be adapted to the evaluation of other prospective contrasting agents/labels to facilitate next-generation DNA sequencing by EM. PMID:23147698
DOE Office of Scientific and Technical Information (OSTI.GOV)
P. H. Titus, S. Avasaralla, A.Brooks, R. Hatcher
2010-09-22
The National Spherical Torus Experiment (NSTX) project is planning upgrades to the toroidal field, plasma current and pulse length. This involves the replacement of the center-stack, including the inner legs of the TF, OH, and inner PF coils. A second neutral beam will also be added. The increased performance of the upgrade requires qualification of the remaining components including the vessel, passive plates, and divertor for higher disruption loads. The hardware needing qualification is more complex than is typically accessible by large scale electromagnetic (EM) simulations of the plasma disruptions. The usual method is to include simplified representations of componentsmore » in the large EM models and attempt to extract forces to apply to more detailed models. This paper describes a more efficient approach of combining comprehensive modeling of the plasma and tokamak conducting structures, using the 2D OPERA code, with much more detailed treatment of individual components using ANSYS electromagnetic (EM) and mechanical analysis. This capture local eddy currents and resulting loads in complex details, and allows efficient non-linear, and dynamic structural analyses.« less
NASA Astrophysics Data System (ADS)
Macmannis, K. R.; Hawley, R. J.
2013-12-01
The mechanisms controlling stability on small streams in steep settings are not well documented but have many implications related to stream integrity and water quality. For example, channel instability on first and second order streams is a potential source of sediment in regulated areas with Total Maximum Daily Loads (TMDLs) on water bodies that are impaired for sedimentation, such as the Chesapeake Bay. Management strategies that preserve stream integrity and protect channel stability are critical to communities that may otherwise require large capital investments to meet TMDLs and other water quality criteria. To contribute to an improved understanding of ephemeral step-pool systems, we collected detailed hydrogeomorphic data on 4 steep (0.06 - 0.12 meter/meter) headwater streams draining to lower relief alluvial valleys in Spencer County, Kentucky, USA. The step-pool streams (mean step height of 0.47 meter, mean step spacing of 4 meters) drained small undeveloped catchments dominated by early successional forest. Data collection for each of the 4 streams included 2 to 3 cross section surveys, bed material particle counts at cross section locations, and profile surveys ranging from approximately 125 to 225 meters in length. All survey data was systematically processed to understand geometric parameters such as cross sectional area, depth, and top width; bed material gradations; and detailed profile measurements such as slope, pool and riffle lengths, pool spacing, pool depth, step height, and step length. We documented the location, frequency, and type of step-forming materials (i.e., large woody debris (LWD), rock, and tree roots), compiling a database of approximately 130 total steps. Lastly, we recorded a detailed tree assessment of all trees located within 2 meters of the top of bank, detailing the species of tree, trunk diameter, and approximate distance from the top of bank. Analysis of geometric parameters illustrated correlations between channel characteristics (e.g., step height was positively correlated to slope while pool spacing was inversely correlated to slope). Most importantly, we assessed the step-forming materials with respect to channel stability. LWD has been widely documented as an important component of geomorphic stability and habitat diversity across many settings; however, our research highlights the importance of roots in providing bed stability in steep, first and second-order ephemeral streams, as 40 percent of the steps in these step-pool systems were controlled by tree roots. Similar to the key member in naturally-occurring log jams, lateral tree roots frequently served as the anchor for channel steps that were often supplemented by rocks or LWD. Assessment of the trees throughout the riparian zone suggested average tree densities of 0.30 trees/square meter or 0.40 trees/meter could provide adequate riparian zone coverage to promote channel stability. These results have implications to land use planning and stormwater management. For example, on developments draining to step-pool systems, maintaining the integrity of the riparian zone would seem to be as important as ensuring hydrologic mimicry if channel integrity is to be preserved.
Dias, Adriana Neves; da Silva, Ana Cristine; Simão, Vanessa; Merib, Josias; Carasek, Eduardo
2015-08-12
This study describes the use of cork as a new coating for bar adsorptive microextraction (BAμE) and its application in determining benzophenone, triclocarban and parabens in aqueous samples by HPLC-DAD. In this study bars with 7.5 and 15 mm of length were used. The extraction and liquid desorption steps for BAμE were optimized employing multivariate and univariate procedures. The desorption time and solvent used for liquid desorption were optimized by univariate and multivariate studies, respectively. For the extraction step the sample pH was optimized by univariate experiments while the parameters extraction time and ionic strength were evaluated using the Doehlert design. The optimum extraction conditions were sample pH 5.5, NaCl concentration 25% and extraction time 90 min. Liquid desorption was carried out for 30 min with 250 μL (bar length of 15 mm) or 100 μL (bar length of 7.5 mm) of ACN:MeOH (50:50, v/v). The quantification limits varied between 1.6 and 20 μg L(-1) (bar length of 15 mm) and 0.64 and 8 μg L(-1) (bar length of 7.5 mm). The linear correlation coefficients were higher than 0.98 for both bars. The method with 7.5 mm bar length showed recovery values between 65 and 123%. The bar-to-bar reproducibility and the repeatability were lower than 13% (n = 2) and 14% (n = 3), respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
Subtraction of cap-trapped full-length cDNA libraries to select rare transcripts.
Hirozane-Kishikawa, Tomoko; Shiraki, Toshiyuki; Waki, Kazunori; Nakamura, Mari; Arakawa, Takahiro; Kawai, Jun; Fagiolini, Michela; Hensch, Takao K; Hayashizaki, Yoshihide; Carninci, Piero
2003-09-01
The normalization and subtraction of highly expressed cDNAs from relatively large tissues before cloning dramatically enhanced the gene discovery by sequencing for the mouse full-length cDNA encyclopedia, but these methods have not been suitable for limited RNA materials. To normalize and subtract full-length cDNA libraries derived from limited quantities of total RNA, here we report a method to subtract plasmid libraries excised from size-unbiased amplified lambda phage cDNA libraries that avoids heavily biasing steps such as PCR and plasmid library amplification. The proportion of full-length cDNAs and the gene discovery rate are high, and library diversity can be validated by in silico randomization.
Ground/Flight Test Techniques and Correlation.
1983-02-01
Approximately 110 flights have been performed so far and the flight test program is essentially finished . Due to its character as an experimental... finish of 0.25 Vm (10 Win) or better. It was 91.4 em (36.00 in) long, with a cone extension that extended the length to 113.0 cm (44.50 in). Transition...weights were embedded during construction to give a representa- tive mass distribution." The surface finish achieved by this method of construction was
Adeolu, Augustine Abiodun; Rabiu, Taopheeq Bamidele; Adeleye, Amos Olufemi
2012-10-01
The traditional care of patients with subacute/chronic subdural haematoma (S/CSDH) often involves delayed mobilization after burr-hole drainage. It is thought that delayed mobilization aids brain re-expansion thereby reducing the risk of recurrence. However, there is paucity of information regarding its efficacy and safety over early mobilization. We evaluated the efficacy and complications of each type of mobilization following burr-hole drainage of S/CSDH. This was a prospective study from October 2004 and September 2010. A total of 50 patients who had burr-hole drainage of S/CSDH were sequentially allocated to either early (day 2) or late (day 7) mobilization (EM or LM) groups (25 patients in each group). Wound related complications, recurrence of haematoma, complications of prolonged bed rest and Glasgow Outcome Score (GOS) at discharge were studied in the two groups. Patients who could not obey commands to mobilize in the early post-operative period were excluded. There were 43 (86%) males and 7 (14%) females. The mean age was 57 years (range: 27-90 years). Fourteen (28%) of the patients were elderly (age > 65 years). Two complications, wound infection in a 76-year old man in the LM group and tension pneumocephalus requiring re-opening burr-hole drainage in a 55-year old man in the EM group were recorded. There was no recurrence or problem associated with prolonged bed rest in the two groups. Five (10%) patients had moderate disability (GOS 4) at discharge (1 EM, 4 LM) while the others (90%) had good recovery (GOS 5) (24 EM, 21 LM). These differences were not statistically significant (p-value: 0.349). It appears that both EM and LM are equally beneficial in the post-operative care of patients following burr-hole drainage of S/CSDH. There is no significant complication referable to the specific type of mobilization. The authors, therefore, advocate EM of patients to reduce the length of hospital stay.
Unique characteristics of motor adaptation during walking in young children.
Musselman, Kristin E; Patrick, Susan K; Vasudevan, Erin V L; Bastian, Amy J; Yang, Jaynie F
2011-05-01
Children show precocious ability in the learning of languages; is this the case with motor learning? We used split-belt walking to probe motor adaptation (a form of motor learning) in children. Data from 27 children (ages 8-36 mo) were compared with those from 10 adults. Children walked with the treadmill belts at the same speed (tied belt), followed by walking with the belts moving at different speeds (split belt) for 8-10 min, followed again by tied-belt walking (postsplit). Initial asymmetries in temporal coordination (i.e., double support time) induced by split-belt walking were slowly reduced, with most children showing an aftereffect (i.e., asymmetry in the opposite direction to the initial) in the early postsplit period, indicative of learning. In contrast, asymmetries in spatial coordination (i.e., center of oscillation) persisted during split-belt walking and no aftereffect was seen. Step length, a measure of both spatial and temporal coordination, showed intermediate effects. The time course of learning in double support and step length was slower in children than in adults. Moreover, there was a significant negative correlation between the size of the initial asymmetry during early split-belt walking (called error) and the aftereffect for step length. Hence, children may have more difficulty learning when the errors are large. The findings further suggest that the mechanisms controlling temporal and spatial adaptation are different and mature at different times.
Ji, Sang Gu; Kim, Myoung Kwon
2015-04-01
To investigate the effect of mirror therapy on the gait of patients with subacute stroke. Randomized controlled experimental study. Outpatient rehabilitation hospital. Thirty-four patients with stroke were randomly assigned to two groups: a mirror therapy group (experimental) and a control group. The stroke patients in the experimental group underwent comprehensive rehabilitation therapy and mirror therapy for the lower limbs. The stroke patients in the control group underwent sham therapy and comprehensive rehabilitation therapy. Participants in both groups received therapy five days per week for four weeks. Temporospatial gait characteristics, such as single stance, stance phase, step length, stride, swing phase, velocity, and cadence, were assessed before and after the four weeks therapy period. A significant difference was observed in post-training gains for the single stance (10.32 SD 4.14 vs. 6.54 SD 3.23), step length (8.47 SD 4.12 vs. 4.83 SD 2.14), and stride length (17.03 SD 6.57 vs 10.54 SD 4.34) between the experimental group and the control group (p < 0.05). However, there were no significant differences between two groups on stance phase, swing phase, velocity, cadence, and step width (P > 0.05). We conclude that mirror therapy may be beneficial in improving the effects of stroke on gait ability. © The Author(s) 2014.
Lawrey, Emma; Jones, Peter; Mitchell, Robin
2012-04-01
Prosthetic hip dislocation is common. This study compares prosthetic hip relocations attempted within the ED by emergency doctors and those under orthopaedic care in the ED or operating theatre (OT). Retrospective cohort study of patients presenting to Auckland City Hospital Adult Emergency Department with prosthetic hip dislocations between 1 January 2003 and 14 April 2008. Primary outcomes were proportion of successful relocation attempts and length of hospital stay. Secondary outcomes were: time to relocation, complications, post-procedural advice, representation rate and long-term outcomes for first-time dislocations. There were 410 eligible presentations during the study period. Emergency medicine (EM) was successful in 254/323 attempts (79%, 95% confidence interval [CI] 74-83). Orthopaedics were successful in 25/35 reductions in the ED (71%, 95% CI 55-84) and 49/51 OT attempts (96%, 95% CI 86-100), P = 0.004 for location OT versus ED. Median times to discharge were 8.8 h for EM, 28.3 h for orthopaedics in the ED and 81 h for orthopaedics in the OT, P < 0.001 for EM versus orthopaedics. Mechanical complications of procedures and early redislocations were infrequent. Complication of sedation were more often seen in OT compared to ED (23/47 [49%, 95% CI 35-63]vs 37/318 [12%, 95% CI 9-16]). There was no difference between EM and orthopaedics in the proportion of hips successfully relocated or complications in the ED; however, EM patients were discharged much sooner, with important resource implications. Procedures carried out in the OT were more successful than in the ED but resulted in prolonged hospital stays and were associated with more complications. © 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Comas, Louise H; Callahan, Hilary S; Midford, Peter E
2014-01-01
Root traits vary enormously among plant species but we have little understanding of how this variation affects their functioning. Of central interest is how root traits are related to plant resource acquisition strategies from soil. We examined root traits of 33 woody species from northeastern US forests that form two of the most common types of mutualisms with fungi, arbuscular mycorrhizas (AM) and ectomycorrhizas (EM). We examined root trait distribution with respect to plant phylogeny, quantifying the phylogenetic signal (K statistic) in fine root morphology and architecture, and used phylogenetically independent contrasts (PICs) to test whether taxa forming different mycorrhizal associations had different root traits. We found a pattern of species forming roots with thinner diameters as species diversified across time. Given moderate phylogenetic signals (K = 0.44–0.68), we used PICs to examine traits variation among taxa forming AM or EM, revealing that hosts of AM were associated with lower branching intensity (rPIC = −0.77) and thicker root diameter (rPIC = −0.41). Because EM evolved relatively more recently and intermittently across plant phylogenies, significant differences in root traits and colonization between plants forming AM and EM imply linkages between the evolution of these biotic interactions and root traits and suggest a history of selection pressures, with trade-offs for supporting different types of associations. Finally, across plant hosts of both EM and AM, species with thinner root diameters and longer specific root length (SRL) had less colonization (rPIC = 0.85, −0.87), suggesting constraints on colonization linked to the evolution of root morphology. PMID:25247056