Sample records for stereomicroscope statistical analysis

  1. Stereomicroscopic evaluation of defects caused by torsional fatigue in used hand and rotary nickel-titanium instruments

    PubMed Central

    Asthana, Geeta; Kapadwala, Marsrat I.; Parmar, Girish J.

    2016-01-01

    Objective: The aim of this study was to evaluate defects caused by torsional fatigue in used hand and rotary nickel-titanium (Ni-Ti) instruments by stereomicroscopic examination. Materials and Methods: One hundred five greater taper Ni-Ti instruments were used including Protaper universal hand (Dentsply Maillefer, Ballaigues, Switzerland), Protaper universal rotary (Dentsply Maillefer, Ballaigues, Switzerland), and Revo-S rotary (MicroMega, Besançon, France) files. Files were used on lower anterior teeth. After every use, the files were observed with both naked eyes and stereomicroscope at 20× magnification (Olympus, Shinjuku, Tokyo, Japan) to evaluate defects caused by torsional fatigue. Scoring was assigned to each file according to the degree of damage. Statistics: The results were statistically analyzed using the Mann-Whitney U test and the Kruskal-Wallis test. Results: A greater number of defects were seen under the stereomicroscope than on examining with naked eyes. However, the difference in methods of evaluation was not statistically significant. Revo-S files showed minimum defects, while Protaper universal hand showed maximum defects. The intergroup comparison of defects showed that the bend in Protaper universal hand instruments was statistically significant. Conclusion: Visible defects in Ni-Ti files due to torsional fatigue were seen by naked eyes as well as by stereomicroscope. This study emphasizes that all the files should be observed before and after every instrument cycle to minimize the risk of separation. PMID:27099415

  2. Stereomicroscopic evaluation of defects caused by torsional fatigue in used hand and rotary nickel-titanium instruments.

    PubMed

    Asthana, Geeta; Kapadwala, Marsrat I; Parmar, Girish J

    2016-01-01

    The aim of this study was to evaluate defects caused by torsional fatigue in used hand and rotary nickel-titanium (Ni-Ti) instruments by stereomicroscopic examination. One hundred five greater taper Ni-Ti instruments were used including Protaper universal hand (Dentsply Maillefer, Ballaigues, Switzerland), Protaper universal rotary (Dentsply Maillefer, Ballaigues, Switzerland), and Revo-S rotary (MicroMega, Besançon, France) files. Files were used on lower anterior teeth. After every use, the files were observed with both naked eyes and stereomicroscope at 20× magnification (Olympus, Shinjuku, Tokyo, Japan) to evaluate defects caused by torsional fatigue. Scoring was assigned to each file according to the degree of damage. The results were statistically analyzed using the Mann-Whitney U test and the Kruskal-Wallis test. A greater number of defects were seen under the stereomicroscope than on examining with naked eyes. However, the difference in methods of evaluation was not statistically significant. Revo-S files showed minimum defects, while Protaper universal hand showed maximum defects. The intergroup comparison of defects showed that the bend in Protaper universal hand instruments was statistically significant. Visible defects in Ni-Ti files due to torsional fatigue were seen by naked eyes as well as by stereomicroscope. This study emphasizes that all the files should be observed before and after every instrument cycle to minimize the risk of separation.

  3. Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars.

    PubMed

    Acar, Buket; Kamburoğlu, Kıvanç; Tatar, İlkan; Arıkan, Volkan; Çelik, Hakan Hamdi; Yüksel, Selcen; Özen, Tuncer

    2015-12-01

    This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

  4. Comparative evaluation of marginal fit and axial wall adaptability of copings fabricated by metal laser sintering and lost-wax technique: An in vitro study.

    PubMed

    Gaikwad, Bhushan Satish; Nazirkar, Girish; Dable, Rajani; Singh, Shailendra

    2018-01-01

    The present study aims to compare and evaluate the marginal fit and axial wall adaptability of Co-Cr copings fabricated by metal laser sintering (MLS) and lost-wax (LW) techniques using a stereomicroscope. A stainless steel master die assembly was fabricated simulating a prepared crown; 40 replicas of master die were fabricated in gypsum type IV and randomly divided in two equal groups. Group A coping was fabrication by LW technique and the Group B coping fabrication by MLS technique. The copings were seated on their respective gypsum dies and marginal fit was measured using stereomicroscope and image analysis software. For evaluation of axial wall adaptability, the coping and die assembly were embedded in autopolymerizing acrylic resin and sectioned vertically. The discrepancies between the dies and copings were measured along the axial wall on each halves. The data were subjected to statistical analysis using unpaired t -test. The mean values of marginal fit for copings in Group B (MLS) were lower (24.6 μm) than the copings in Group A (LW) (39.53 μm), and the difference was statistically significant ( P < 0.05). The mean axial wall discrepancy value was lower for Group B (31.03 μm) as compared with Group A (54.49 μm) and the difference was statistically significant ( P < 0.05). The copings fabricated by MLS technique had better marginal fit and axial wall adaptability in comparison with copings fabricated by the LW technique. However, the values of marginal fit of copings fabricated that the two techniques were within the clinically acceptable limit (<50 μm).

  5. Advances in stereomicroscopy

    NASA Astrophysics Data System (ADS)

    Schnitzler, H.; Zimmer, Klaus-Peter

    2008-09-01

    Similar to human's binocular vision, stereomicroscopes are comprised of two optical paths under a convergence angle providing a full perspective insight into the world's microstructure. The numerical aperture of stereomicroscopes has continuously increased over the years, reaching the point where the lenses of left and right perspective paths touched each other. This constraint appeared as an upper limit for the resolution of stereomicroscopes, as the resolution of a stereomicroscope was deduced from the numerical apertures of the two equally sized perspective channels. We present the optical design and advances in resolution of the world's first asymmetrical stereomicroscope, which is a technological breakthrough in many aspects of stereomicroscopes. This unique approach uses a large numerical aperture and thus an, so far, unachievable high lateral resolution in the one path, and a small aperture in the other path, which provides a high depth of field ("Fusion Optics"). This new concept is a technical challenge for the optical design of the zoom system as well as for the common main objectives. Furthermore, the new concept makes use of the particular way in which perspective information by binocular vision is formed in the human's brain. In conjunction with a research project at the University of Zurich, Leica Microsystems consolidated the functionality of this concept in to a new generation of stereomicroscopes.

  6. Comparative Analysis of Crack Propagation in Roots with Hand and Rotary Instrumentation of the Root Canal -An Ex-vivo Study.

    PubMed

    Kumari, Manju Raj; Krishnaswamy, Manjunath Mysore

    2016-07-01

    Success of any endodontic treatment depends on strict adherence to 'endodontic triad'. Preparation of root canal system is recognized as being one of the most important stages in root canal treatment. At times, we inevitably end up damaging root dentin which becomes a Gateway for infections like perforation, zipping, dentinal cracks and minute intricate fractures or even vertical root fractures, thereby resulting in failure of treatment. Several factors may be responsible for the formation of dentinal cracks like high concentration of sodium hypochlorite, compaction methods and various canal shaping methods. To compare and evaluate the effects of root canal preparation techniques and instrumentation length on the development of apical root cracks. Seventy extracted premolars with straight roots were mounted on resin blocks with simulated periodontal ligaments, exposing 1-2 mm of the apex followed by sectioning of 1mm of root tip for better visualization under stereomicroscope. The teeth were divided into seven groups of 10 teeth each - a control group and six experimental groups. Subgroup A & B were instrumented with: Stainless Steel hand files (SS) up to Root Canal Length (RCL) & (RCL -1 mm) respectively; sub group C & D were instrumented using ProTaper Universal (PTU) up to RCL and (RCL -1mm) respectively; subgroup E & F were instrumented using ProTaper Next (PTN) up to RCL & (RCL -1 mm) respectively. Stereomicroscopic images of the instrumentation sequence were compared for each tooth. The data was analyzed statistically using descriptive analysis by 'Phi' and 'Cramers' test to find out statistical significance between the groups. The level of significance was set at p< 0.05 using SPSS software. Stainless steel hand file group showed most cracks followed by ProTaper Universal & ProTaper Next though statistically not significant. Samples instrumented up to 1mm short of working length (RCL-1mm) showed lesser number of cracks. All groups showed cracks formation, the stainless steel group being the highest. Working 1mm short of apex reduces the incidence of crack formation.

  7. A simple method to compare firing pin marks using stereomicroscope and Microsoft office (Windows 8) tools.

    PubMed

    Suresh, R

    2017-08-01

    Pertinent marks of fired cartridge cases such as firing pin, breech face, extractor, ejector, etc. are used for firearm identification. A non-standard semiautomatic pistol and four .22rim fire cartridges (head stamp KF) is used for known source comparison study. Two test fired cartridge cases are examined under stereomicroscope. The characteristic marks are captured by digital camera and comparative analysis of striation marks is done by using different tools available in the Microsoft word (Windows 8) of a computer system. The similarities of striation marks thus obtained are highly convincing to identify the firearm. In this paper, an effort has been made to study and compare the striation marks of two fired cartridge cases using stereomicroscope, digital camera and computer system. Comparison microscope is not used in this study. The method described in this study is simple, cost effective, transport to field study and can be equipped in a crime scene vehicle to facilitate immediate on spot examination. The findings may be highly helpful to the forensic community, law enforcement agencies and students. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A comparison of microscopic and spectroscopic identification methods for analysis of microplastics in environmental samples.

    PubMed

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Han, Gi Myung; Rani, Manviri; Lee, Jongmyoung; Shim, Won Joon

    2015-04-15

    The analysis of microplastics in various environmental samples requires the identification of microplastics from natural materials. The identification technique lacks a standardized protocol. Herein, stereomicroscope and Fourier transform infrared spectroscope (FT-IR) identification methods for microplastics (<1mm) were compared using the same samples from the sea surface microlayer (SML) and beach sand. Fragmented microplastics were significantly (p<0.05) underestimated and fiber was significantly overestimated using the stereomicroscope both in the SML and beach samples. The total abundance by FT-IR was higher than by microscope both in the SML and beach samples, but they were not significantly (p>0.05) different. Depending on the number of samples and the microplastic size range of interest, the appropriate identification method should be determined; selecting a suitable identification method for microplastics is crucial for evaluating microplastic pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Micro-computed Tomography versus the Cross-sectioning Method to Evaluate Dentin Defects Induced by Different Mechanized Instrumentation Techniques.

    PubMed

    Stringheta, Carolina Pessoa; Pelegrine, Rina Andréa; Kato, Augusto Shoji; Freire, Laila Gonzales; Iglecias, Elaine Faga; Gavini, Giulio; Bueno, Carlos Eduardo da Silveira

    2017-12-01

    The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Effectiveness of an infiltrant on sealing of composite restoration margins with/without artificial caries.

    PubMed

    Tulunoglu, Ozlem; Tulunoglu, Ibrahim Fevzi; Antonson, Sibel A; Campillo-Funollet, Marc; Antonson, Donald; Munoz-Viveros, Carlos

    2014-11-01

    The aim of this in vitro study was to evaluate the effectiveness of a resin infiltrant (ICON) on marginal sealing ability of class II resin restorations with/without-caries. Forty-eight noncarious human pre-molar teeth were embedded and MO and DO preparations of standard dimensions were prepared. The left side of dentin margins of the cavities were left nonbonded (UB) while the right side were bonded using total etch-bonding agent and all restored with a Nanohybrid composite. The teeth were thermocycled and half of the specimens in the UB and B groups were subjected to an artificial caries process. ICON was applied to caries and noncaries subgroups following the manufacturer's directions. Impressions were made at each step: after the restorations were completed, thermocycling, artificial caries procedures, and infiltrant application and the silicone tag lengths were measured with a stereomicroscope. The specimens were immersed in 0.5% basic fuchsine at 37° C for 24 hours, sectioned and microleakage was evaluated with a stereomicroscope. Selected samples and their replicas were assessed for marginal quality under a stereomicroscope and SEM. Statistical evaluation of the data were made using Kruskal-Wallis, Mann-Whitney U and Wilcoxon Sign Rank tests. While bonding application did not create a meaningful difference, the thermocycling and artificial caries significantly increased the gap length and microleakage (p < 0.05). ICON application was decreased the microleakage, created gap-free margins and closed the gaps which were previously occurred at the same cavities (p < 0.05). A resin infiltrant (ICON) application decreased the microleakage, created gap-free margins and closed the gaps, which previously occurred at the same cavities. Approximal application of resin infiltrant may increase the success of the class II composite restorations also reduced the risk of needing more complex restoration therapy.

  11. Analysis of Dental Enamel Surface Submitted to Fruit Juice Plus Soymilk by Micro X-Ray Fluorescence: In Vitro Study.

    PubMed

    Brito, Janaína Salmos; Santos Neto, Alexandrino; Silva, Luciano; Menezes, Rebeca; Araújo, Natália; Carneiro, Vanda; Moreno, Lara Magalhães; Miranda, Jéssica; Álvares, Pâmella; Nevares, Giselle; Xavier, Felipe; Arruda, José Alcides; Bessa-Nogueira, Ricardo; Santos, Natanael; Queiroz, Gabriela; Sobral, Ana Paula; Silveira, Márcia; Albuquerque, Diana; Gerbi, Marleny

    2016-01-01

    This paper aimed to analyze the in vitro industrialized fruit juices effect plus soy to establish the erosive potential of these solutions. Seventy bovine incisors were selected after being evaluated under stereomicroscope. Their crowns were prepared and randomly divided into 7 groups, using microhardness with allocation criteria. The crowns were submitted to the fruit juice plus soy during 15 days, twice a day. The pH values, acid titration, and Knoop microhardness were recorded and the specimens were evaluated using X-ray microfluorescence (µXRF). The pH average for all juices and after 3 days was significantly below the critical value for dental erosion. In average, the pH value decreases 14% comparing initial time and pH after 3 days. Comparing before and after, there was a 49% microhardness decrease measured in groups (p < 0.05). Groups G1, G2, G5, and G6 are above this average. The analysis by μXRF showed a decrease of approximately 7% Ca and 4% P on bovine crowns surface. Florida (FL) statistical analysis showed a statistically significant 1 difference between groups. Thus, a tooth chance to suffer demineralization due to industrialized fruit juices plus soy is real.

  12. Effects of Reciproc, ProTaper Next and WaveOne Gold on Root Canal Walls: A Stereomicroscope Analysis.

    PubMed

    Cassimiro, Marcely; Romeiro, Kaline; Gominho, Luciana; de Almeida, Andressa; Silva, Lívia; Albuquerque, Diana

    2018-01-01

    The aim of this study was to analyse the potential occurrence of dentinal defects after root canal preparation using three engine-driven instruments. Eighty permanent mandibular incisors were selected. Twenty teeth did not undergo preparation, and the remaining teeth were divided into three groups ( n =20): Reciproc (REC) , ProTaper Next (PTN) and WaveOne Gold (WOG). The samples were dyed with methylene blue, sectioned perpendicularly to the long axis in 3-, 6- and 9-mm slices and were finally observed under a stereomicroscope (under 25×). The absence/presence of dentinal defects was documented by two blind observers. The data were analysed using Pearson's chi -squared test with a confidence level of 95% ( P =0.05). The time to prepare the samples was recorded, and the groups were compared using F -test (ANOVA). The control group did not present any defects, and the differences between the control and experimental groups were statistically significant ( P <0.05). WOG, PTN and REC caused microcracks on 60%, 33.33% and 18.33% of the samples, respectively. No significant differences between the groups in the 3-mm sections ( P =0.126) were observed. There were significant differences in the 6-mm ( P =0.042) and 9-mm sections ( P <0.001). When WOG and PTN were used to perform root canal preparation, a significant difference was found in the average time ( P =0.047). All the used instruments caused dentinal defects in the root dentin. All the instruments were used to perform the preparation with a similar average time.

  13. A comparative evaluation of efficacy of protaper universal rotary retreatment system for gutta-percha removal with or without a solvent.

    PubMed

    Kumar, M Sita Ram; Sajjan, Girija S; Satish, Kalyan; Varma, K Madhu

    2012-09-01

    The aim was to evaluate and compare the efficacy of ProTaper Universal rotary retreatment system with or without solvent and stainless steel hand files for endodontic filling removal from root canals and also to compare retreatment time for each system. Thirty extracted mandibular premolars with single straight canals were endodontically treated. Teeth were divided into three major groups, having 10 specimens each. Removal of obturating material in group 1 by stainless steel hand files with RC Solve, group 2 by ProTaper Universal retreatment instruments and group 3 by ProTaper Universal retreatment instruments along with RC solve was done. Retreatment was considered complete for all groups when no filling material was observed on the instruments. The retreatment time was recorded for each tooth. All specimens were grooved longitudinally in a buccolingual direction. The split halves were examined under a stereomicroscope and images were captured and analyzed. The remaining filling debris area ratios were considered for statistical analysis. With ANOVA test, statistical analysis showed that there was statistically no significant difference regarding the amount of filling remnants between the groups (P < 0.05). Differences between the means of groups are statistically significant regarding the retreatment time. Irrespective of the technique used, all the specimens had some remnants on the root canal wall. ProTaper Universal retreatment system files alone proved to be faster than the other experimental groups.

  14. Efficacy of ProTaper Retreatment System in Root Canals Obturated with Gutta-Percha Using Two Different Sealers and GuttaFlow

    PubMed Central

    Siotia, Jaya; Acharya, Shashi Rashmi; Gupta, Sunil Kumar

    2011-01-01

    Objective. To compare the efficacy of ProTaper retreatment files in removing three different obturating materials. Study Design. Forty-five human, single-rooted premolars were divided into three experimental groups. Group 1 was obturated with gutta-percha and AH Plus sealer, Group 2 was obturated with gutta-percha and zinc oxide eugenol sealer, and Group 3 was obturated with GuttaFlow. Retreatment was done using the ProTaper universal rotary retreatment files. Root halves were visualized using magnifying loops at 3X magnification and optical stereomicroscope at 10X magnification. Images were analyzed using AutoCAD 2004 software to calculate area of the remaining debris in the canal. For statistical analysis were used variance test and ANOVA. Results. Total debris/canal area ratio between the three groups showed a statistically significant difference (P < 0.001). Conclusion. ProTaper retreatment system did not produce completely clean canals in any of the groups. However, it had the best efficacy towards removing silicon based obturating material GuttaFlow. PMID:22114598

  15. Sealing ability of cermet ionomer cement as a retrograde filling material.

    PubMed

    Aktener, B O; Pehlivan, Y

    1993-03-01

    An in vitro dye leakage study was performed to compare the sealing ability of high copper amalgam with cavity varnish and cermet ionomer cement with and without varnish when used as retrofilling materials. The root canals of 54 maxillary anterior teeth were instrumented and obturated with gutta-percha and sealer. The apical 3 mm of the roots were resected and apical class I cavity preparations were made. The roots were then randomly divided into three groups and retrofilled with one of the experimental materials. After 72 h of immersion in India ink, the roots were cleared and evaluated for leakage with a stereomicroscope. Statistical analysis indicated that the cermet ionomer cement with varnish group had significantly less leakage than the amalgam group (P < 0.0014) and the cermet ionomer cement without varnish group (P < 0.001). There was no significant difference between the other two groups (P > 0.05).

  16. Sealing ability of lateral condensation, thermoplasticized gutta-percha and flowable gutta-percha obturation techniques: A comparative in vitro study.

    PubMed

    Kumar, Nallkkapalayam Somasundaram Mohan; Prabu, P S; Prabu, Neethika; Rathinasamy, Shobana

    2012-08-01

    To evaluate and compare the sealing ability between the clod lateral condensation, thermoplasticized gutta-percha, and flowable gutta-percha obturation technique, under a stereomicroscope at ×40 magnification. Sixty single rooted teeth were selected and canals were shaped with K3 NiTi files. Irrigation was performed with 5.25% NaOCl and 17% ethylenediaminetetraacetic acid (EDTA). The teeth were then separated into three groups depending on the type of obturation technique: Group A, obturated using the lateral condensation technique and AH Plus sealer; Group B, obturated with thermoplasticized gutta-percha tech (Obtura III Max) and AH Plus sealer; and Group C, obturated using flowable gutta-percha technique (GuttaFlow). After storing the teeth in 100% humidity for 7 days at 37°C, the roots of the teeth were sectioned at five levels. The sections were then observed under a stereomicroscope at ×40 magnification and the images were analyzed for area of voids (AV) and frequency of voids. The data were statistically analyzed using the SPSS version 17 software. The 95% confidence intervals (CI) were calculated. One-way analysis of variance with post hoc test and non-parametric Mann-Whitney U test were carried out to compare the means. The lowest mean of AV was recorded in the thermoplasticized gutta-percha (Obtura III Max) group [1.0% (95% CI=0.5-1.5)]. This was statistically and significantly different from flowable gutta-percha (GuttaFlow) group [3.0% (95% CI=2.1-3.9)]. There was no significant difference between the thermoplasticized gutta-percha group and lateral condensation group [1.6% (95% CI=1.0-2.2)] with regard to the AV, but there was a statistically significant difference between the lateral condensation and flowable gutta-percha groups. The flowable gutta-percha group showed the maximum number of voids [56% (95% CI=48-64)], which was significantly higher than those in the lateral condensation [26% (95% CI=19-34)] and thermoplasticized gutta-percha [15% (95% CI=10-21)] groups. The thermoplasticized gutta-percha technique (Obtura III Max) had better adaptability to the canal walls when compared to the flowable gutta-percha (GuttaFlow) obturation and lateral condensation techniques.

  17. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study

    PubMed Central

    H Bhandi, Shilpa; T S, Subhash

    2013-01-01

    Introduction: Microleakage continues to be a main reason for failure of root canal treatment where the challenge has been to achieve an adequate seal between the internal structure and the main obturating material. The objective of this study is to compare the sealing ability of 3 newer obturating materials GuttaFlow, Resilon/Epiphany system (RES) and Thermafil, using silver nitrate dye and observing under stereomicroscope. Methodology: Thirty single rooted teeth were divided into following groups. Group I : GuttaFlow ;Group II : Resilon /Epiphany sealer Group III : Thermafil with AH-Plus sealer. Teeth were decoronated and instrumented with profile rotary system and obturated with specified materials. Apical seal was determined by dye penetration method using silver nitrate. Then the specimens were transversely sectioned at each mm till 3 mm from the apex. Dye leakage was determined using stereomicroscope. Statistical analysis of the results was performed using Kruskall-Wallis test. Results: The results showed that Group II i.e., Resilon with Epiphany sealer showed the least amount of microleakage when compared to Group I i.e., GuttaFlow and Group III i.e., Thermafil with AH-plus sealer. Conclusion: Based on the results of this study it can be concluded that RES had higher sealing ability followed by Thermafil and GuttaFlow in vitro but further studies have to be carried out to make a direct correlation between these results and invivo situation. How to cite this article: Bhandi S H, Subhash T S. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study. J Int Oral Health 2013; 5(1):54-65. PMID:24155579

  18. What is the changing frequency of diamond burs?

    PubMed

    Emir, Faruk; Ayyildiz, Simel; Sahin, Cem

    2018-04-01

    The purpose of this study was to determine the changing frequency of a diamond bur after multiple usages on 3 different surfaces. Human premolar teeth (N = 26), disc shaped direct metal laser sintered CoCr (N = 3) and zirconia specimens (N = 3) were used in this study. Groups named basically as Group T for teeth, Group M for CoCr, and Group Z for zirconia. Round tapered black-band diamond bur was used. The specimens were randomly divided into three groups and placed with a special assembly onto the surveyor. 1, 5, and 10 preparation protocols were performed to the first, second, and third sub-groups, respectively. The subgroups were named according to preparation numbers (1, 5, 10). The mentioned bur of each group was then used at another horizontal preparation on a new tooth sample. The same procedure was used for CoCr and zirconia disc specimens. All of the bur surfaces were evaluated using roughness analysis. Then, horizontal tooth preparation surfaces were examined under both stereomicroscope and SEM. The depth maps of tooth surfaces were also obtained from digital stereomicroscopic images. The results were statistically analyzed using One-Way ANOVA, and the Tukey HSD post-hoc tests (α=.05). All of the groups were significantly different from the control group ( P <.001). There was no significant difference between groups Z5 and Z10 ( P =.928). Significant differences were found among groups T5, M5, and Z5 ( P <.001). Diamond burs wear after multiple use and they should be changed after 5 teeth preparations at most. A diamond bur should not be used for teeth preparation after try-in procedures of metal or zirconia substructures.

  19. Effects of Reciproc, ProTaper Next and WaveOne Gold on Root Canal Walls: A Stereomicroscope Analysis

    PubMed Central

    Cassimiro, Marcely; Romeiro, Kaline; Gominho, Luciana; de Almeida, Andressa; Silva, Lívia; Albuquerque, Diana

    2018-01-01

    Introduction: The aim of this study was to analyse the potential occurrence of dentinal defects after root canal preparation using three engine-driven instruments. Methods and Materials: Eighty permanent mandibular incisors were selected. Twenty teeth did not undergo preparation, and the remaining teeth were divided into three groups (n=20): Reciproc (REC), ProTaper Next (PTN) and WaveOne Gold (WOG). The samples were dyed with methylene blue, sectioned perpendicularly to the long axis in 3-, 6- and 9-mm slices and were finally observed under a stereomicroscope (under 25×). The absence/presence of dentinal defects was documented by two blind observers. The data were analysed using Pearson’s chi-squared test with a confidence level of 95% (P=0.05). The time to prepare the samples was recorded, and the groups were compared using F-test (ANOVA). Results: The control group did not present any defects, and the differences between the control and experimental groups were statistically significant (P<0.05). WOG, PTN and REC caused microcracks on 60%, 33.33% and 18.33% of the samples, respectively. No significant differences between the groups in the 3-mm sections (P=0.126) were observed. There were significant differences in the 6-mm (P=0.042) and 9-mm sections (P<0.001). When WOG and PTN were used to perform root canal preparation, a significant difference was found in the average time (P=0.047). Conclusion: All the used instruments caused dentinal defects in the root dentin. All the instruments were used to perform the preparation with a similar average time. PMID:29707020

  20. Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

    PubMed

    Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya

    2012-11-01

    Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.

  1. Marginal Accuracy of Castings Fabricated with Ringless Casting Investment System and Metal Ring Casting Investment System: A Comparative Study.

    PubMed

    Kalavathi, M; Sachin, Bhuvana; Prasanna, B G; Shreeharsha, T V; Praveen, B; Ragher, Mallikarjuna

    2016-02-01

    The thermal expansion of the investment can be restricted by the metal casting ring because the thermal expansion of the ring is less than that of the investment. The ringless casting procedure is in use in clinical dentistry, though there is little scientific data to support its use in fixed partial dentures. In this study, marginal discrepancy of castings produced with the ringless casting technique and the conventional technique using the metal rings were compared. A total of 30 wax patterns were fabricated directly on a metal die. Optical stereomicroscope was used to measure the marginal discrepancy between the metal die and wax patterns. A total of 15 castings were invested using Bellavest T phosphate-bonded investment with the ringless technique and 15 were invested with the same investment with a metal ring; 30 castings were produced using a nickel-chromium ceramo-metal alloy. The internal surface of the castings was not modified and seated with finger pressure. The vertical marginal discrepancy was measured using an optical stereomicroscope at a magnification of 100x. The data obtained were statistically analyzed using students t-test (paired t-test and unpaired t-test). The castings of the ringless technique provided less vertical marginal discrepancy (240.56 ± 45.81 μ) than the castings produced with the conventional metal ring technique (281.98± 53.05 μ). The difference was statistically significant. The ringless casting technique had produced better marginal accuracy compared with conventional casting technique. Ringless casting system can be used routinely for clinical purpose.

  2. Evaluation of the marginal fit of metal copings fabricated on three different marginal designs using conventional and accelerated casting techniques: an in vitro study.

    PubMed

    Vaidya, Sharad; Parkash, Hari; Bhargava, Akshay; Gupta, Sharad

    2014-01-01

    Abundant resources and techniques have been used for complete coverage crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-h procedure before completion. Accelerated casting techniques have been used, but may not result in castings with matching marginal accuracy. The study measured the marginal gap and determined the clinical acceptability of single cast copings invested in a phosphate-bonded investment with the use of conventional and accelerated methods. One hundred and twenty cast coping samples were fabricated using conventional and accelerated methods, with three finish lines: Chamfer, shoulder and shoulder with bevel. Sixty copings were prepared with each technique. Each coping was examined with a stereomicroscope at four predetermined sites and measurements of marginal gaps were documented for each. A master chart was prepared for all the data and was analyzed using Statistical Package for the Social Sciences version. Evidence of marginal gap was then evaluated by t-test. Analysis of variance and Post-hoc analysis were used to compare two groups as well as to make comparisons between three subgroups . Measurements recorded showed no statistically significant difference between conventional and accelerated groups. Among the three marginal designs studied, shoulder with bevel showed the best marginal fit with conventional as well as accelerated casting techniques. Accelerated casting technique could be a vital alternative to the time-consuming conventional casting technique. The marginal fit between the two casting techniques showed no statistical difference.

  3. Comparative evaluation of traditional and self-priming hydrophilic resin

    PubMed Central

    Singla, Ruchi; Bogra, Poonam; Singal, Bhawana

    2012-01-01

    Background: The purpose of this study was to compare the microleakage of traditional composite (Charisma/Gluma Comfort Bond) and self-priming resin (Embrace Wetbond). Materials and Methods: Standardized Class V cavities partly in enamel and cementum were prepared in 20 extracted human premolars. Teeth were divided into two groups. Group 1 was restored with Charisma/Gluma Comfort Bond and Group 2 with Embrace Wetbond. The specimens were stored in distilled water at room temperature for 24 h and then subjected to 200 thermocycles at 5°C and 55°C with a 1 min dwell time. After thermocycling teeth were immersed in a 0.2% solution of methylene blue dye for 24 h. Teeth were sectioned vertically approximately midway through the facial and lingual surfaces using a diamond saw blade. Microleakage was evaluated at enamel and cementum surfaces using 10 × stereomicroscope. The statistical analysis was performed using Wilcoxon signed-rank test. Results: Wetbond showed less microleakage at occlusal and gingival margins as compared with Charisma/Gluma Comfort Bond and the results were statistically significant (P < 0.05). Conclusion: Class V cavities restored with Embrace Wetbond with fewer steps and fewer materials offers greater protection against microleakage at the tooth restorative interface. PMID:22876008

  4. Tensile bond strength of filled and unfilled adhesives to dentin.

    PubMed

    Braga, R R; Cesar, P F; Gonzaga, C C

    2000-04-01

    To determine the tensile bond strength of three filled and two unfilled adhesives applied to bovine dentin. Fragments of the labial dentin of bovine incisors were embedded in PVC cylinders with self-cure acrylic resin, and ground flat using 200 grit and 600 grit sandpaper. The following adhesive systems were tested (n=10): Prime & Bond NT, Prime & Bond NT dual cure, Prime & Bond 2.1, OptiBond Solo and Single Bond. A 3 mm-diameter bonding surface was delimited using a perforated adhesive tape. After etching with 37% phosphoric acid and adhesive application, a resin-based composite truncated cone (TPH, shade A3) was built. Tensile test was performed after 24 hrs storage in distilled water at 37 degrees C. Failure mode was accessed using a x10 magnification stereomicroscope. Weibull statistical analysis revealed significant differences in the characteristic strength between Single Bond and Prime & Bond NT dual cure, and between Single Bond and Prime & Bond 2.1. The Weibull parameter (m) was statistically similar among the five groups. Single Bond and Prime & Bond NT showed areas of dentin cohesive failure in most of the specimens. For OptiBond Solo, Prime & Bond NT dual cure and Prime & Bond 2.1 failure was predominantly adhesive.

  5. Evaluation of marginal fit of two all-ceramic copings with two finish lines

    PubMed Central

    Subasi, Gulce; Ozturk, Nilgun; Inan, Ozgur; Bozogullari, Nalan

    2012-01-01

    Objectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designs. Methods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (α =.05). Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065). Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (⩽120 μm). PMID:22509119

  6. Comparison of Microleakage under Rebonded Stainless Steel Orthodontic Brackets Using Two Methods of Adhesive Removal: Sandblast and Laser.

    PubMed

    Tudehzaeim, Mohamad Hossein; Yassaei, Soghra; Taherimoghadam, Shohreh

    2015-02-01

    Debonding is a common occurrence in orthodontic treatment and a considerable number of orthodontists prefer to rebond the detached brackets because of economic issues. The aim of this study was to compare the microleakage beneath rebonded stainless steel brackets using two methods of adhesive removal namely sandblast and laser. Sixty human premolar teeth were randomly divided into three groups. Following bonding the brackets, group 1 served as the control group. Brackets in groups 2 and 3 were debonded, and adhesive removal from the bracket bases was done by means of sandblasting and Er-YAG laser, respectively. After rebonding, teeth in each group were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope. Marginal microleakage at the adhesive-enamel and bracket-adhesive interfaces in the occlusal and gingival margins was determined. Statistical analysis was done using the Kruskal-Wallis test. Comparison of the microleakage scores among the three groups revealed no statistically significant difference (P > 0.05). At the enamel-adhesive interface, the gingival margins in all groups showed higher microleakage while in the adhesive-bracket interface, the occlusal margin exhibited greater microleakage. Er-YAG laser irradiation and sandblasting for adhesive removal from the debonded brackets yielded clinically acceptable microleakage scores.

  7. Comparison of Microleakage under Rebonded Stainless Steel Orthodontic Brackets Using Two Methods of Adhesive Removal: Sandblast and Laser

    PubMed Central

    Tudehzaeim, Mohamad Hossein; Yassaei, Soghra; Taherimoghadam, Shohreh

    2015-01-01

    Objectives: Debonding is a common occurrence in orthodontic treatment and a considerable number of orthodontists prefer to rebond the detached brackets because of economic issues. The aim of this study was to compare the microleakage beneath rebonded stainless steel brackets using two methods of adhesive removal namely sandblast and laser. Materials and Methods: Sixty human premolar teeth were randomly divided into three groups. Following bonding the brackets, group 1 served as the control group. Brackets in groups 2 and 3 were debonded, and adhesive removal from the bracket bases was done by means of sandblasting and Er-YAG laser, respectively. After rebonding, teeth in each group were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope. Marginal microleakage at the adhesive-enamel and bracket-adhesive interfaces in the occlusal and gingival margins was determined. Statistical analysis was done using the Kruskal-Wallis test. Results: Comparison of the microleakage scores among the three groups revealed no statistically significant difference (P > 0.05). At the enamel-adhesive interface, the gingival margins in all groups showed higher microleakage while in the adhesive-bracket interface, the occlusal margin exhibited greater microleakage. Conclusion: Er-YAG laser irradiation and sandblasting for adhesive removal from the debonded brackets yielded clinically acceptable microleakage scores. PMID:26056521

  8. Characterization and coating stability evaluation of nickel-titanium orthodontic esthetic wires: an in vivo study.

    PubMed

    Argalji, Nina; Silva, Eduardo Moreira da; Cury-Saramago, Adriana; Mattos, Claudia Trindade

    2017-08-21

    The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed using a stereomicroscope to measure coating thickness and inner metallic dimensions. The wires were also exposed to oral environment in 11 orthodontic active patients for 21 days. After removing the samples, stereomicroscopy images were captured, coating loss was measured and its percentage was calculated. Three segments of each wire (one as-received and two after oral exposure) were observed using scanning electron microscopy for a qualitative analysis of the labial surface of the wires. The Lilliefors test and independent t-test were applied to verify normality of data and statistical differences between wires, respectively. The significance level adopted was 0.05. The results showed that the differences between the wires while comparing inner height and thickness were statistically significant (p < 0.0001). In average, the most recently launched wire presented a coating thickness twice that of the control wire, which was also a statistically significant difference. The coating loss percentage was also statistically different (p = 0.0346) when the latest launched wire (13.27%) was compared to the control (29.63%). In conclusion, the coating of the most recent wire was thicker and more uniform, whereas the control had a thinner coating on the edges. After oral exposure, both tested wires presented coating loss, but the most recently launched wire exhibited better results.

  9. A new Agraecina spider species from the Balkan Peninsula (FYR Macedonia) (Araneae: Liocranidae).

    PubMed

    Deltshev, Christo; Wang, Chunxia

    2016-05-30

            Specimens were collected using pitfall traps. Coloration is described from alcohol-preserved specimens. Specimens were examined and measured using a Wild M5A stereomicroscope. Further details were studied and measured under an Olympus BX41 compound microscope. All drawings were made using a drawing apparatus attached to a Leica stereomicroscope. Male palps and female genitalia were examined and illustrated after they were dissected from the spiders' bodies. Photos were taken with an Olympus C7070 wide zoom digital camera mounted on an Olympus SZX12 stereomicroscope. The images were montaged using Helicon Focus image stacking software. Measurements of the legs are taken from the dorsal side. Total length of the body includes the chelicerae. All measurements were taken in mm. Abbreviations used in text include: AME, anterior median eyes; ALE, anterior lateral eyes; EM, embolus; MA, median apophysis; CD, copulatory duct; ST, spermatheca; fe, femur; pa, patella; ti, tibia; mt, metatarsus; p, prolateral; d, dorsal; r, retrolateral; v, ventral. Type specimens are deposited in the National Museum of Natural History (NMNHS), Sofia, Bulgaria.

  10. Evaluation of the Effect of Different Food Media on the Marginal Integrity of Class V Compomer, Conventional and Resin-Modified Glass-Ionomer Restorations: An In Vitro Study

    PubMed Central

    Dinakaran, Shiji

    2015-01-01

    Background: Cervical lesions of anterior and posterior teeth are a common finding in routine dental practice. They are of much concern to the patient, if present in esthetically sensitive regions. Adhesive tooth-colored restorative materials are generally recommended for treating such lesions. The aim of the present study was to evaluate and compare the effect of various food media (lime juice, tea, coffee, and Coca-Cola) on the marginal integrity of Class V compomer (Dyract®), conventional glass-ionomer (Fuji II) and resin-modified glass-ionomer (Fuji II LC improved) restorations along their cemental and enamel margins with saline as control media. Materials and Methods: After restoration of prepared Class V cavities in human premolars with the three different materials (n = 8), they were immersed in the test media for 7 days and then stained with methylene blue dye. Buccolingual sections were prepared and examined under stereomicroscope and scores (0-2) were given. Results: Data were analyzed statistically using one-way analysis of variance in SPSS version 16.0. P < 0.05 were considered statistically significant. Conclusions: Among the three tested materials Compomer (Dyract®) showed more marginal integrity than the other two. Micro leakage values of Fuji II and Fuji II LC improved were statistically significant in acidic media (lime juice and Coca-Cola) compared to saline. Enamel margins showed more marginal adaptation than cemental margins. PMID:25878480

  11. Evaluation of the effect of different food media on the marginal integrity of class v compomer, conventional and resin-modified glass-ionomer restorations: an in vitro study.

    PubMed

    Dinakaran, Shiji

    2015-03-01

    Cervical lesions of anterior and posterior teeth are a common finding in routine dental practice. They are of much concern to the patient, if present in esthetically sensitive regions. Adhesive tooth-colored restorative materials are generally recommended for treating such lesions. The aim of the present study was to evaluate and compare the effect of various food media (lime juice, tea, coffee, and Coca-Cola) on the marginal integrity of Class V compomer (Dyract(®)), conventional glass-ionomer (Fuji II) and resin-modified glass-ionomer (Fuji II LC improved) restorations along their cemental and enamel margins with saline as control media. After restoration of prepared Class V cavities in human premolars with the three different materials (n = 8), they were immersed in the test media for 7 days and then stained with methylene blue dye. Buccolingual sections were prepared and examined under stereomicroscope and scores (0-2) were given. Data were analyzed statistically using one-way analysis of variance in SPSS version 16.0. P < 0.05 were considered statistically significant. Among the three tested materials Compomer (Dyract(®)) showed more marginal integrity than the other two. Micro leakage values of Fuji II and Fuji II LC improved were statistically significant in acidic media (lime juice and Coca-Cola) compared to saline. Enamel margins showed more marginal adaptation than cemental margins.

  12. The surface orientation of some Apollo 14 rocks.

    NASA Technical Reports Server (NTRS)

    Hoerz, F.; Morrison, D. A.; Hartung, J. B.

    1972-01-01

    Detailed stereomicroscopic studies of the distribution of microcraters, soil covers, and glass coatings were performed to reconstruct the most recent surface orientations of selected Apollo 14 rocks. Surface orientations could be established for rocks 14053, 14073, 14301, 14303, 14307, 14310, and 14311 (which includes rock 14308). A tentative orientation of rock 14055 is suggested, and comments concerning the surface history of rocks 14302, 14305, and 14318 are presented. The examination of rocks 14066, 14306, and 14321 indicates that these specimens have complicated surface histories that prevent reconstruction of their orientation by the criteria that were established in these stereomicroscopic studies.

  13. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate when used as root-end filling materials.

    PubMed

    Shahi, Shahriar; Rahimi, Saeed; Yavari, Hamid Reza; Shakouie, Sahar; Nezafati, Saeed; Abdolrahimi, Majid

    2007-12-01

    This in vitro study used dye penetration to compare the sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate when used as root-end filling materials. Ninety-six single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH26 root canal sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 20 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After decoronation of the teeth and application of nail polish, the teeth were exposed to India ink for 72 hours and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. Statistical analysis showed that there were no significant differences among the 4 experimental groups.

  14. [Deformation evaluation of ProTaper nickel-titanium rotary instruments in curved canals instrumentation in vitro].

    PubMed

    Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei

    2008-04-01

    To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.

  15. Microscopic morphological changes of the tooth surface in relation to fixed orthodontic treatment.

    PubMed

    Preoteasa, Cristina Teodora; NiŢoi, Dan Florin; Preoteasa, Elena

    2015-01-01

    Orthodontic treatment has, as any other medical intervention, in addition to its benefits, side effects, some of them being perceived as unavoidable. The aim of this case series was to microscopically evaluate the changes of the tooth surface in relation to fixed orthodontic treatment. A case series study was implemented by the usage of four extracted first maxillary premolars, from patients with previous orthodontic treatment, of 12 and 23 months. Analysis was performed using the high precision stereomicroscope (Axiovert, Carl Zeiss, Germany), at magnifications from 10× to 50×. The tooth surface corresponding to the bracket bonding area registered numerous disorderly grooves and cracks, with various directions and depths, and was flattened, having lower convexity compared to teeth surfaces where brackets were not bonded. Root resorption lacunae were more frequently observed in teeth under orthodontic treatment, these having various depths, and sizes considerably larger than those observed in teeth without orthodontic treatment. Following orthodontic treatment, teeth exhibit changes that can be perceived as being directly linked to this medical intervention. These teeth changes usually have low or moderate severity, which can be influenced at some degree by the clinical conduct of the orthodontic treatment. The stereomicroscope proved to be a high sensitivity tool for the analysis of morphological changes of teeth in relation to the fixed orthodontic treatment.

  16. Canal Aberration Assessment in Simulated Root Canals: a Comparative Study

    PubMed Central

    Jakupovic, Selma; Konjhodzic, Alma; Brankovic, Lajla Hasic; Korac, Samra; Tahmiscija, Irmina; Dzankovic, Aida; Glamoc, Alma Gavranovic

    2017-01-01

    Aim: The aim of this study was to compare time of preparation and canal aberrations in a simulated root canals after using three different rotary systems: Endostar E5, Endostar E3 and T One File Gold. Materials and Methods: A total of 90 endodontic training blocks were used in this study and divided into three groups consisting of 30 each (n = 30). Blocks processing was performed by thirty dentists without any prior experience in rotary instrumentation techniques. In the first group blocks were prepared using Endostar E5, in second one with Endostar E3 and in third one with T One File Gold system. The preparation time was measured. The postoperative image of each block was taken by stereomicroscope and canal aberrations (ledge and instrument fracture) was recorded. Statistical analysis was done by SPSS software. Results: Instrumentation with T One File Gold system is significantly faster compared to instrumentation with Endostar E5 and Endostar E3 systems (p <0.05). There are no statistically significant differences in the type and number of procedural errors between Endostar E5, Endostar E3 and T One File Gold systems when the operators have no previous experience in rotary instrumentation techniques. Conclusion: Under the conditions of this study, the incidence of examined canal aberrations were similar for all tested systems. The preparation time was significantly shorter with single file system. PMID:28974834

  17. Assessment of the mechanics of a tissue-engineered rat trachea in an image-processing environment.

    PubMed

    Silva, Thiago Henrique Gomes da; Pazetti, Rogerio; Aoki, Fabio Gava; Cardoso, Paulo Francisco Guerreiro; Valenga, Marcelo Henrique; Deffune, Elenice; Evaristo, Thaiane; Pêgo-Fernandes, Paulo Manuel; Moriya, Henrique Takachi

    2014-07-01

    Despite the recent success regarding the transplantation of tissue-engineered airways, the mechanical properties of these grafts are not well understood. Mechanical assessment of a tissue-engineered airway graft before implantation may be used in the future as a predictor of function. The aim of this preliminary work was to develop a noninvasive image-processing environment for the assessment of airway mechanics. Decellularized, recellularized and normal tracheas (groups DECEL, RECEL, and CONTROL, respectively) immersed in Krebs-Henseleit solution were ventilated by a small-animal ventilator connected to a Fleisch pneumotachograph and two pressure transducers (differential and gauge). A camera connected to a stereomicroscope captured images of the pulsation of the trachea before instillation of saline solution and after instillation of Krebs-Henseleit solution, followed by instillation with Krebs-Henseleit with methacholine 0.1 M (protocols A, K and KMCh, respectively). The data were post-processed with computer software and statistical comparisons between groups and protocols were performed. There were statistically significant variations in the image measurements of the medial region of the trachea between the groups (two-way analysis of variance [ANOVA], p<0.01) and of the proximal region between the groups and protocols (two-way ANOVA, p<0.01). The technique developed in this study is an innovative method for performing a mechanical assessment of engineered tracheal grafts that will enable evaluation of the viscoelastic properties of neo-tracheas prior to transplantation.

  18. Evaluation of Effect of Zirconia Surface Treatment, Using Plasma of Argon and Silane, on the Shear Bond Strength of Two Composite Resin Cements

    PubMed Central

    Ramdev, Poojya; Shruthi, C S

    2017-01-01

    Introduction Yttria stabilised tetragonal zirconia opens new vistas for all ceramic restoration by the mechanism of transformation toughening, making it much stronger compared to all other ceramic materials. Currently, it is the most recent core material for all ceramic fixed partial dentures due to its ability to withstand high simulated masticatory loads. Problems which have been reported with zirconia restorations involve the core cement interface leading to loss of retention of the prosthesis. Different reasons which have been reported for the same include the lack of adhesion between zirconia and commonly used cements due to absence of silica phase which makes zirconia not etchable. In addition, the hydrophobic nature of zirconia causes low wettability of zirconia surface by the adhesive cements which are commonly used. Aim The purpose of this in vitro study was to compare and evaluate the effect of two pre-treatments of zirconia, using plasma of argon and silane, on the shear bond strength values of two composite resin cements to zirconia and to evaluate the failure pattern of the debonded areas using stereomicroscopic analysis. Materials and Methods Sixty zirconia discs (10 mm×2 mm) were randomly divided into three groups (n=20), following surface treatment, with airborne particle abrasion, using 110 µm Al2O3: Group I (control), Group II (plasma of argon cleaning), and Group III (application of silane primer). Each group had two subgroups based on the type of resin cement used for bonding: subgroup A; Rely X Ultimate (3M ESPE) and subgroup B; Panavia F (Kuraray). In subgroup A, Rely X universal silane primer and in subgroup B Clearfil ceramic primer was used. Shear bond strengths were determined after water storage for one day and thermocycling for 5000 cycles. Data (megapascal) were analyzed using ANOVA and Bonferroni test. Specimens were subjected to stereomicroscopic analysis, for evaluation of failure pattern. Results Group III produced the highest shear bond strength followed by Group II and Group I. Subgroup A showed higher shear bond strength than Subgroup B. Stereomicroscopic analysis showed cohesive failure in Group III, while in Group I adhesive failure was seen. Conclusion Silane primer application caused maximum increase in shear bond strength due to increased wettability. Argon plasma treatment was less effective in comparison to silane treatment. Air abrasion when used alone resulted in lower bond strength values, thereby making it necessary to use a combination of surface treatments. Rely X Ultimate cement was superior to Panavia F in terms of adhesive bonding to zirconia. PMID:28969271

  19. Surface modification for bonding between amalgam and orthodontic brackets.

    PubMed

    Wongsamut, Wittawat; Satrawaha, Sirichom; Wayakanon, Kornchanok

    2017-01-01

    Testing of methods to enhance the shear bond strength (SBS) between orthodontic metal brackets and amalgam by sandblasting and different primers. Three hundred samples of amalgam restorations (KerrAlloy ® ) were prepared in self-cured acrylic blocks, polished, and divided into two groups: nonsandblasted and sandblasted. Each group was divided into five subgroups with different primers used in surface treatment methods, with a control group of bonded brackets on human mandibular incisors. Following the surface treatments, mandibular incisor brackets (Unitek ® ) were bonded on the amalgam with adhesive resin (Transbond XT ® ). The SBS of the samples was tested. The adhesive remnant index (ARI) and failure modes were then determined under a stereo-microscope. Two-way analysis of variance, Chi-square, and Kruskal-Wallis tests were performed to calculate the correlations between and among the SBS and ARI values, the failure modes, and surface roughness results. There were statistically significant differences of SBS among the different adhesive primers and sandblasting methods ( P < 0.05). The sandblasted amalgam with Assure Plus ® showed the highest SBS ( P < 0.001). Samples mainly showed an ARI score = 1 and mix-mode failure. There was a statistically significant difference of surface roughness between nonsandblasted amalgam and sandblasted amalgam ( P < 0.05), but no significant differences among priming agents ( P > 0.05). Using adhesive primers with sandblasting together effectively enhances the SBS between orthodontic metal brackets and amalgam. The two primers with the ingredient methacryloxydecyl dihydrogen phosphate (MDP) monomer, Alloy Primer ® and Assure Plus ® , were the most effective. Including sandblasting in the treatment is essential to achieve the bonding strength required.

  20. Marginal Fit of Metal-Ceramic Copings: Effect of Luting Cements and Tooth Preparation Design.

    PubMed

    de Almeida, Juliana Gomes Dos Santos Paes; Guedes, Carlos Gramani; Abi-Rached, Filipe de Oliveira; Trindade, Flávia Zardo; Fonseca, Renata Garcia

    2017-12-22

    To evaluate the effect of the triad finish line design, axial wall convergence angle, and luting cement on the marginal fit of metal copings used in metal-ceramic crowns. Schematic dies and their respective copings were cast in NiCr alloy. The dies exhibited the following finish line/convergence angle combinations: sloping shoulder/6°, sloping shoulder/20°, shoulder/6°, shoulder/20°. Marginal fit was evaluated under a stereomicroscope, before and after cementation. Copings were air-abraded with 50 μm Al 2 O 3 particles and cemented with Cimento de Zinco, RelyX U100, or Panavia F cements (n = 10/group). Data were square-root transformed and analyzed by 3-way factorial random effect model and Tukey's post hoc test (α = 0.05). Statistical analysis showed significance for the interactions finish line and convergence angle (p < 0.05), convergence angle and time (p < 0.001), and luting cement and time (p < 0.001). Sloping shoulder/20° provided the highest marginal discrepancy when compared to the other finish line/convergence angle combinations, which were statistically similar among each other. For both convergence angles and for all luting cements, the marginal discrepancy was significantly higher after cementation. Before and after cementation, 6° provided better marginal fit than 20°. After cementation, Panavia F provided higher marginal discrepancy than Cimento de Zinco. Lower convergence angle combined with shoulder and a low-consistency luting cement is preferable to cement metal copings. © 2017 by the American College of Prosthodontists.

  1. Comparison of different techniques for obturating experimental internal resorptive cavities.

    PubMed

    Goldberg, F; Massone, E J; Esmoris, M; Alfie, D

    2000-06-01

    Forty extracted maxillary central incisors were instrumented at the working length to a #50 file. The roots were sectioned transversely with a diamond disk at 7 mm from the anatomical apex. At the opening of the root canal of each section, hemicircular cavities were drilled with a specially designed bur. The corresponding root sections were cemented with glue, thus obtaining root canals with similar cavities that simulated internal resorptions. Teeth were embedded in plaster casts to facilitate their handling. The specimens were randomly separated into four groups of 10. The following obturation techniques were evaluated: lateral compaction (group A), hybrid technique (group B), Obtura II (group C), and Thermafil (group D). AH26 was used as the sealer. After obturation, the plaster was removed and the teeth were radiographed in buccolingual and mesiodistal directions to evaluate the quality of the obturation at the IRC. The incisors were then cut with a scalpel at the same level as the previous section, to examine, under a stereomicroscope, the type of material that filled the IRC. Obtura II gave the best results and in most of the specimens obturated with this technique, the IRC were filled mainly with gutta-percha. Statistical analysis of the data indicated that the differences between group C and the other groups were significant (P < 0.05).

  2. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth

    PubMed Central

    Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin

    2012-01-01

    Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929

  3. Extended Area Exit Pupil Viewer.

    DTIC Science & Technology

    1985-08-01

    viewing to normal Zoom-500 stereomicroscope viewing. Previous EAEP viewers typically have incorporated a spinning lenticular screen and associated...is uncorrected spherical aberration and astigmatism that limit image resolution. The complex optical path in the microscope also makes it inefficient

  4. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques.

    PubMed

    Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed

    2017-01-01

    Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.

  5. Stereomicroscopic imaging technique for the quantification of cold flow in drug-in-adhesive type of transdermal drug delivery systems.

    PubMed

    Krishnaiah, Yellela S R; Katragadda, Usha; Khan, Mansoor A

    2014-05-01

    Cold flow is a phenomenon occurring in drug-in-adhesive type of transdermal drug delivery systems (DIA-TDDS) because of the migration of DIA coat beyond the edge. Excessive cold flow can affect their therapeutic effectiveness, make removal of DIA-TDDS difficult from the pouch, and potentially decrease available dose if any drug remains adhered to pouch. There are no compendial or noncompendial methods available for quantification of this critical quality attribute. The objective was to develop a method for quantification of cold flow using stereomicroscopic imaging technique. Cold flow was induced by applying 1 kg force on punched-out samples of marketed estradiol DIA-TDDS (model product) stored at 25°C, 32°C, and 40°C/60% relative humidity (RH) for 1, 2, or 3 days. At the end of testing period, dimensional change in the area of DIA-TDDS samples was measured using image analysis software, and expressed as percent of cold flow. The percent of cold flow significantly decreased (p < 0.001) with increase in size of punched-out DIA-TDDS samples and increased (p < 0.001) with increase in cold flow induction temperature and time. This first ever report suggests that dimensional change in the area of punched-out samples stored at 32°C/60%RH for 2 days applied with 1 kg force could be used for quantification of cold flow in DIA-TDDS. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  6. In Vitro Comparison Of Fluoride Gel Alone and in Combination With Er,Cr:YSGG Laser on Reducing White Spot Lesions in Primary Teeth.

    PubMed

    Molaasadollah, Fatemeh; Asnaashari, Mohammad; Mashhadi Abbas, Fatemeh; Jafary, Maral

    2017-01-01

    Introduction: Laser therapy has been suggested as a method for caries-prevention, and ErCr:YSGG laser is increasingly used in dentistry. This study aimed to compare the efficacy of fluoride gel alone and in conjunction with Er,Cr:YSGG laser for remineralization of white spot lesions (WSLs) in primary teeth. Methods: This study was conducted on 20 primary teeth with WSLs extracted for orthodontic reasons. Three sections were made of each tooth at the site of WSLs. The surface area of WSLs was measured under a stereomicroscope at ×25 magnification. Samples were assigned to 3 groups of control (group 1), exposure to 1.23% APF gel for 4 minutes (group 2) and Er,Cr:YSGG laser (0.5 W power, 20 Hz frequency, 60% water, 40% air, pulse duration of 5±1 seconds) plus fluoride (group 3). All samples were stored in artificial saliva for 10 days and then the surface area of the WSLs was measured again under a stereomicroscope. Data were analyzed using the Kruskal-Wallis, MannWhitney and Wilcoxon signed rank tests. Results: The reduction in surface area of the WSLs was significantly different between the control and fluoride ( P <0.001) and also the control and laser plus fluoride groups ( P <0.001); the difference between fluoride and laser plus fluoride groups was not significant ( P =0.265). Comparison of the surface area of WSLs before and after the intervention showed no significant difference in group one ( P =0.737) while this difference in groups 2 ( P <0.001) and 3 ( P <0.001) was statistically significant. Conclusion: The results showed that Er,Cr:YSGG laser irradiation plus 1.23% APF gel was not significantly different from the application of fluoride gel alone in enhancing the remineralization of WSLs.

  7. Comparative evaluation of microleakage of a carbomer/fluoroapatite-enhanced glass-ionomer cement on primary teeth restorations.

    PubMed

    Tolidis, K; Boutsiouki, C; Gerasimou, P

    2016-09-01

    Carbomer cement represents a novel glass-ionomer which gradually mineralises into fluoroapatite. Purpose of this study was to evaluate microleakage around restorations in deciduous teeth made with composite resin, conventional glass-ionomer cement, resin-modified glass-ionomer cement and carbomer/fluoroapatite-enhanced glass-ionomer cement. A group of 40 primary upper canines, primary upper and lower molars was divided into 4 groups (n=10). Class I cavities were prepared by diamond cylindrical bur at high speed and were restored with a composite resin (Group 1), with a glass- ionomer cement (Group 2), with a resin-modified glass-ionomer cement (Group 3) and with a carbomer/fluoroapatite-enhanced glass- ionomer cement (Group 4). Hard tissue's bonding involved, in the case of composite resin a total etch bonding procedure, and in glass ionomers the use of their respective primers. Restorations were finished and polished. A 24-hour water storage was followed by thermocycling (1500 cycles, 5°C - 36°C - 55°C - 36°C with a dwell time of 15 seconds) and dye penetration test with immersion in 5% methylene blue for 24 hours. In order to assess the degree of microleakage longitudinal cuts were produced by means of a microtome at 0.5 mm and at 1 mm from the restoration margin, and photographs were taken with a stereomicroscope at 100X. Microleakage was classified according to the number of surfaces and the depth at which dye penetration was observed. Data were analysed with ANOVA and post-hoc analysis was performed with Bonferonni test (p<0.05). Statistical analysis exhibited no significant statistical difference between Group 2 and Group 3 (p>0.05). Statistical difference was exhibited between Group 3 and Group 4 (p<0.01), with Group 4 exhibiting lower microleakage values. Group 1 exhibited the lowest mean microleakage values and statistical difference in comparison with all groups (p<0.001). Group 4 exhibited the lowest microleakage values among the cements. Superior marginal integrity is achieved in restored primary teeth when composite resin is used. If the clinical case suggests the use of a glass-ionomer cement, carbomer/fluoroapatite-enhanced glass-ionomer cement is prefered in terms of microleakage.

  8. Comparison of the shear bond strength of self-adhesive resin cements to enamel and dentin with different protocol of application

    PubMed Central

    Moghaddas, Mohammad Javad; Hossainipour, Zahra; Majidinia, Sara; Ojrati, Najmeh

    2017-01-01

    Aim The aim of the present study was to determine the shear bond strength of self-adhesive resin cements to enamel and dentin with and without surface treatments, and compare them with conventional resin cement as the control group. Methods In this experimental study, buccal and lingual surface of the thirty sound human premolars were polished in order to obtain a flat surface of enamel (E) in buccal, and dentin (D) in lingual. Sixty feldspathic ceramic blocks (2×3×3 mm) were prepared and randomly divided into six groups (n=10). Each block was cemented to the prepared surface (30 enamel and 30 dentin surface) according to different protocol: E1 and D1; RelyX ARC as control group, E2, D2; RelyX Unicem, E3, D3; acid etching +RelyX Unicem. The specimens were termocycled and subjected to shear forces by a universal testing machine at a cross head speed of 0.5 mm/min. The mode of fracture were evaluated by stereomicroscope. Data were analyzed with descriptive statistical methods using SPSS version 15. One-way ANOVA, and post hoc Tukey tests were used to compare bond strengths between the groups with different adhesives at α=0.05. Results Statistical analysis showed no significant differences within the enamel subgroups, but there were significant differences within the dentinal subgroups, and statistically significant differences were found between the groups D1and D3 (p=0.02). Comparison between similar enamel and dentinal subgroups showed that there was a significant difference just between the subgroups E3 and D3 (p=0.01). Conclusion Elective etching of enamel did not lead to significant increase in the shear bond strength of RelyX Unicem in comparison to RelyX ARC. On the other hand, elective etching of dentin reduces the bond strength of RelyX Unicem with the dentin. PMID:28979732

  9. Comparison of the shear bond strength of self-adhesive resin cements to enamel and dentin with different protocol of application.

    PubMed

    Moghaddas, Mohammad Javad; Hossainipour, Zahra; Majidinia, Sara; Ojrati, Najmeh

    2017-08-01

    The aim of the present study was to determine the shear bond strength of self-adhesive resin cements to enamel and dentin with and without surface treatments, and compare them with conventional resin cement as the control group. In this experimental study, buccal and lingual surface of the thirty sound human premolars were polished in order to obtain a flat surface of enamel (E) in buccal, and dentin (D) in lingual. Sixty feldspathic ceramic blocks (2×3×3 mm) were prepared and randomly divided into six groups (n=10). Each block was cemented to the prepared surface (30 enamel and 30 dentin surface) according to different protocol: E1 and D1; RelyX ARC as control group, E2, D2; RelyX Unicem, E3, D3; acid etching +RelyX Unicem. The specimens were termocycled and subjected to shear forces by a universal testing machine at a cross head speed of 0.5 mm/min. The mode of fracture were evaluated by stereomicroscope. Data were analyzed with descriptive statistical methods using SPSS version 15. One-way ANOVA, and post hoc Tukey tests were used to compare bond strengths between the groups with different adhesives at α=0.05. Statistical analysis showed no significant differences within the enamel subgroups, but there were significant differences within the dentinal subgroups, and statistically significant differences were found between the groups D1and D3 (p=0.02). Comparison between similar enamel and dentinal subgroups showed that there was a significant difference just between the subgroups E3 and D3 (p=0.01). Elective etching of enamel did not lead to significant increase in the shear bond strength of RelyX Unicem in comparison to RelyX ARC. On the other hand, elective etching of dentin reduces the bond strength of RelyX Unicem with the dentin.

  10. Effects of drying agents on bond strength of etch-and-rinse adhesive systems to enamel immediately after bleaching.

    PubMed

    Niat, Alireza Boruzi; Yazdi, Fatmeh Maleknejad; Koohestanian, Niloufar

    2012-12-01

    To determine the effect of drying agents and adhesive solvents on the bond strength of resin composite to enamel immediately after bleaching. Sixty healthy human premolars were bleached using 15% carbamide peroxide gel and randomly divided into three groups according to the immersing solutions applied immediately after bleaching: 70% alcohol, acetone, and distilled water. Each group was randomly divided into two subgroups according to the adhesives that were applied: an alcohol-based adhesive (Single Bond) and an acetone-based adhesive (One Step). By using rubber washers, composite Z100 was placed onto the enamel and shear bond strength was evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The type of failure was also assessed using a stereomicroscope. The data were statistically analyzed by two-way ANOVA and Tukey's post-hoc test (α = 0.05). Fisher's Exact test was used to evaluate differences in the failure modes. Statistical analysis showed that the bond strength of the distilled water groups was significantly lower than that of the other groups, but the bond strengths of the two groups where a drying agent was applied were similar to that of the unbleached group. The acetone-based adhesive (One Step) provided higher bond strength than did the alcohol-based adhesive (Single Bond) (p < 0.05). There was no interaction between the two variables (p > 0.05). Fisher's Exact test showed there was no significant difference in the failure mode of all the experimental groups (p > 0.05). The application of drying agents improves the bond strength of resin composite to bleached enamel. Furthermore, the acetone-based adhesive used in the study had a higher bond strength to bleached enamel than did the alcohol-based adhesive used.

  11. Microleakage of bonded amalgam restorations using different adhesive agents with dye under vacuum: an in vitro study.

    PubMed

    Parolia, Abhishek; Kundabala, M; Gupta, Vaibhav; Verma, Mudita; Batra, Chandni; Shenoy, Ramya; Srikant, N

    2011-01-01

    In an effort to minimize tooth preparation, yet provide additional retention to compromised tooth structure, bonded amalgam restorations were introduced. Various resin-based adhesives have been tried earlier under bonded amalgam restorations. Still there are controversies regarding the outcome of bonded amalgam restorations regarding their adaptability to the tooth structure and microleakage. Therefore, this study was undertaken to compare the microleakage of bonded amalgam restorations using different adhesive materials. Standard Class I cavities were prepared on occlusal surfaces of 60 human molars. Teeth (n=60) were divided into three groups according to the material employed, as follows: group I: amalgam with glass ionomer cement (GIC) (type I); group II: amalgam with resin cement (Panavia F 2.0) and group III: amalgam with Copalex varnish as a control. Following restoration, the teeth were submitted to thermal cycling. The teeth were subsequently immersed in 2% rhodamine B dye under vacuum for 48 hours and sectioned to allow the assessment of microleakage under stereomicroscope. The values were tabulated and the results were statistically analyzed using analysis of variance (ANOVA), Tukey's post hoc test and Kruskal-Wallis test. Amalgam with type I GIC showed the least leakage with no statistically significant difference (P value 0.226) when compared to amalgam with Panavia F 2.0 and amalgam with varnish (P value 0.107). It can be concluded that bonded amalgam with type I GIC is a good alternative to amalgam with resin cement (Panavia F 2.0) and amalgam with varnish for large restorations, with the added advantages of GICs. Bonded amalgam restorations prevent over-preparation and reduce the tooth flexure. GIC type I under amalgam provides chemical bonding in between amalgam and tooth structure and thus reduces the microleakage.

  12. Development of a Tele-Micro-Robot for Telemanipulation of a Microscopic Environment

    NASA Technical Reports Server (NTRS)

    Goldfarb, Michael

    1998-01-01

    The objective of the proposed work was to design and develop the mechanical equivalent of a stereomicroscope in order to eliminate the mismatch that currently exists between one's ability to observe a microscopic environment and one's ability to manipulate it.

  13. Nd:YAG laser system for ophthalmic microsurgery

    NASA Astrophysics Data System (ADS)

    Savastru, Dan; Ristici, Esofina; Dragu, T.; Cotirlan, C.; Miclos, Sorin; Mustata, Marina

    2005-04-01

    The Nd:YAG solid state laser can be used in ophthalmologic microsurgery because of its specific wavelength of 1064 nm, which has the property to penetrate the transparent medium of the eye. We design a specific ophthalmic system, containing a Q-switch Nd:YAG laser, an optical stereomicroscope and an aiming system. This laser-stereomicroscope system is used for eye examination and for microsurgical proceedings like posterior capsulotomy and pupilar membranectomy. We had to design an optical scheme of the laser to settle the radiation route. In order to cover the medical domain of the energies, we calibrate eleven attenuation filters using ratiometric method. For a correct position of the place where the laser pulse strikes, we used an original system consisting of two red laser diodes mounted on each side of the binocular One of the advantages of this laser system is taht the output energies can be varied widely (0.8-15 mJ), making a great numbers of applications in clinical ophthalmology possible.

  14. Stereomicroscopic evaluation of dentinal defects induced by new rotary system: "ProTaper NEXT".

    PubMed

    Shori, Deepa Deepak; Shenoi, Pratima Ramakrishna; Baig, Arshia R; Kubde, Rajesh; Makade, Chetana; Pandey, Swapnil

    2015-01-01

    The objective of this study was to evaluate dentinal defects formed by new rotary system - Protaper next™ (PTN). Sixty single-rooted premolars were selected. All specimens were decoronated and divided into four groups, each group having 15 specimens. Group I specimens were prepared by Hand K-files (Mani), Group II with ProTaper Universal (PT; Dentsply Maillefer), Group III with Hero Shaper (HS; Micro-Mega, Besancon, France), and Group IV with PTN (Dentsply Maillefer). Roots of each specimen were sectioned at 3, 6, and 9mm from the apex and were then viewed under a stereomicroscope to evaluate presence or absence of dentinal defects. In roots prepared with hand files (HFs) showed lowest percentage of dentinal defects (6.7%); whereas in roots prepared with PT, HS, and PTN it was 40, 66.7, and 26.7%, respectively. There was significant difference between the HS group and the PTN group (P < 0.05). All rotary files induced defects in root dentin, whereas the hand instruments induced minimal defects.

  15. Comparison of push-out bond strengths of Resilon with three different sealers.

    PubMed

    Stiegemeier, Danielle; Baumgartner, J Craig; Ferracane, Jack

    2010-02-01

    The purpose of this study was to evaluate the push-out bond strengths of different obturating materials. Forty single-rooted human extracted teeth were used in this study. The teeth were instrumented and irrigated by using 5.25% NaOCl, 15% ethylenediaminetetraacetic acid, and sterile water. The teeth were then filled with Resilon/RealSeal, Resilon/RealSeal SE, Resilon/MetaSeal , or gutta-percha/Kerr EWT sealer. The roots were then sectioned into 1-mm-thick slices and subjected to vertical loading to displace the obturating material toward the coronal side of the slice. The bond strength was then calculated and subjected to statistical analysis. Slices were examined by using a stereomicroscope at 30x to determine the mode of failure. The mean push-out bond strengths were as follows: Resilon/RealSeal, 1.45 +/- 0.99 MPa; RealSeal SE, 0.88 +/- 0.49 MPa; Resilon/MetaSeal, 2.41 +/- 1.7 MPa; and gutta-percha/Kerr EWT sealer, 2.32 +/- 0.74 MPa. The push-out bond strengths of Resilon/MetaSeal and gutta-percha/Kerr EWT were significantly (P < .05) higher than either Resilon/RealSeal or Resilon/RealSeal SE. Resilon/MetaSeal and gutta-percha/Kerr EWT did not differ significantly. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Effects of pulp capping materials on fracture resistance of Class II composite restorations

    PubMed Central

    Kucukyilmaz, Ebru; Yasa, Bilal; Akcay, Merve; Savas, Selcuk; Kavrik, Fevzi

    2015-01-01

    Objective: The aim of this study was to investigate the effect of cavity design and the type of pulp capping materials on the fracture resistance of Class II composite restorations. Materials and Methods: Sixty freshly extracted, sound molar teeth were selected for the study. A dovetail cavity on the mesio-occlusal and a slot cavity on disto-occlusal surfaces of each tooth were prepared, and the teeth were divided 4 groups which one of them as a control group. The pulp capping materials (TheraCal LC, Calcimol LC, Dycal) applied on pulpo-axial wall of each cavity, and the restoration was completed with composite resin. The teeth were subjected to a compressive load in a universal mechanical testing machine. The surfaces of the tooth and restoration were examined under a stereomicroscope. The data were analyzed using factorial analysis of variance and Tukey's test. Results: For pulp capping materials, the highest fracture load (931.15 ± 203.81 N) and the lowest fracture load (832.28 ± 245.75 N) were calculated for Control and Dycal group, respectively. However, there were no statistically significant differences among all groups (P > 0.05). The fracture load of the dovetail groups was significantly higher than those of the slot cavity groups (P < 0.05). Conclusion: Dovetail cavity design shows better fracture resistance in Class II composite restorations, independent of used or not used pulp capping materials. PMID:26038653

  17. Evaluation of shear bond strength of orthodontic brackets bonded with nano-filled composites.

    PubMed

    Chalipa, Javad; Akhondi, Mohammad Sadegh Ahmad; Arab, Sepideh; Kharrazifard, Mohammad Javad; Ahmadyar, Maryam

    2013-09-01

    The purpose of this study was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT) was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel) were used in groups II and III respectively. The teeth were stored in distilled water at 37°C for 24 hours, thermocycled in distilled water and debonded with a universal testing machine at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was also evaluated using a stereomicroscope. AELITE Aesthetic Enamel nano-composite revealed a SBS value of 8.44±2.09 MPa, which was higher than Transbond XT (6.91±2.13) and Filtek TM Supreme XT (6.04±2.01). Statistical analysis revealed a significant difference between groups II and III (P < 0.05). No significant difference was found between groups I and III, and between groups I and II (P > 0.05). Evaluation of ARI showed that Transbond XT left fewer adhesive remains on teeth after debonding. Results of this study indicate that the aforementioned nano-composites can be successfully used for bonding orthodontic brackets.

  18. Microleakage and penetration depth of different fissure sealant materials after cyclic thermo-mechanic and brushing simulation.

    PubMed

    Hatirli, Hüseyin; Yasa, Bilal; Yasa, Elif

    2018-01-30

    The aim of the study was to evaluate microleakage and the penetration-depths of different fissure-sealant materials applied with/without enameloplasty after cyclic aging. One-hundred-sixty mandibular molars were divided into non-invasive and enameloplasty preparation groups and eight material subgroups, including: flowable composites (microhyrid, nanohybrid, and nanofilled), three resin-based (unfilled, filled, and highly-filled), a giomer-based, and a glass-ionomer-based fissure sealant. Specimens were subjected to two-year cyclic chewing and brushing simulation. After 5% basic-fuchsin dye penetration, specimens were sectioned and scored under stereomicroscope. Kruskal-Wallis statistical data showed that preparation type significantly affected the penetration of all tested materials (p<0.05), but not significantly affected microleakage (p>0.05). Flowable composites showed the best and the glass-ionomer-based sealant showed the worst penetration and microleakage. Slight preparation of fissures is not important in microleakage. However, enameloplasty significantly enhanced the depth of penetration of the sealants. Flowable composites offer promising results at the fissure sealing.

  19. Comparison of marginal accuracy of castings fabricated by conventional casting technique and accelerated casting technique: an in vitro study.

    PubMed

    Reddy, S Srikanth; Revathi, Kakkirala; Reddy, S Kranthikumar

    2013-01-01

    Conventional casting technique is time consuming when compared to accelerated casting technique. In this study, marginal accuracy of castings fabricated using accelerated and conventional casting technique was compared. 20 wax patterns were fabricated and the marginal discrepancy between the die and patterns were measured using Optical stereomicroscope. Ten wax patterns were used for Conventional casting and the rest for Accelerated casting. A Nickel-Chromium alloy was used for the casting. The castings were measured for marginal discrepancies and compared. Castings fabricated using Conventional casting technique showed less vertical marginal discrepancy than the castings fabricated by Accelerated casting technique. The values were statistically highly significant. Conventional casting technique produced better marginal accuracy when compared to Accelerated casting. The vertical marginal discrepancy produced by the Accelerated casting technique was well within the maximum clinical tolerance limits. Accelerated casting technique can be used to save lab time to fabricate clinical crowns with acceptable vertical marginal discrepancy.

  20. Micromechanics of composite laminate compression failure

    NASA Technical Reports Server (NTRS)

    Guynn, E. Gail; Bradley, Walter L.

    1986-01-01

    The Dugdale analysis for metals loaded in tension was adapted to model the failure of notched composite laminates loaded in compression. Compression testing details, MTS alignment verification, and equipment needs were resolved. Thus far, only 2 ductile material systems, HST7 and F155, were selected for study. A Wild M8 Zoom Stereomicroscope and necessary attachments for video taping and 35 mm pictures were purchased. Currently, this compression test system is fully operational. A specimen is loaded in compression, and load vs shear-crippling zone size is monitored and recorded. Data from initial compression tests indicate that the Dugdale model does not accurately predict the load vs damage zone size relationship of notched composite specimens loaded in compression.

  1. In vitro activity of ten essential oils against Sarcoptes scabiei.

    PubMed

    Fang, Fang; Candy, Kerdalidec; Melloul, Elise; Bernigaud, Charlotte; Chai, Ling; Darmon, Céline; Durand, Rémy; Botterel, Françoise; Chosidow, Olivier; Izri, Arezki; Huang, Weiyi; Guillot, Jacques

    2016-11-22

    The development of alternative approaches in ectoparasite management is currently required. Essential oils have been demonstrated to exhibit fumigant and topical toxicity to a number of arthropods. The aim of the present study was to assess the potential efficacy of ten essential oils against Sarcoptes scabiei. The major chemical components of the oils were identified by GC-MS analysis. Contact and fumigation bioassays were performed on Sarcoptes mites collected from experimentally infected pigs. For contact bioassays, essential oils were diluted with paraffin to get concentrations at 10, 5, and even 1% for the most efficient ones. The mites were inspected under a stereomicroscope 10, 20, 30, 40, 50, 60, 90, 120, 150, and 180min after contact. For fumigation bioassay, a filter paper was treated with 100 μL of the pure essential oil. The mites were inspected under a stereomicroscope for the first 5min, and then every 5min until 1h. Using contact bioassays, 1% clove and palmarosa oil killed all the mites within 20 and 50min, respectively. The oils efficacy order was: clove > palmarosa > geranium > tea tree > lavender > manuka > bitter orange > eucalyptus > Japanese cedar. In fumigation bioassays, the efficacy order was: tea tree > clove > eucalyptus > lavender > palmarosa > geranium > Japanese cedar > bitter orange > manuka. In both bioassays, cade oil showed no activity. Essential oils, especially tea tree, clove, palmarosa, and eucalyptus oils, are potential complementary or alternative products to treat S. scabiei infections in humans or animals, as well as to control the mites in the environment.

  2. A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment

    PubMed Central

    Keum, Eun-Cheol

    2013-01-01

    PURPOSE This study evaluated the effectiveness of various methods for removing provisional cement from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive cementation. MATERIALS AND METHODS Forty implant fixture analogues and abutments were embedded in resin blocks. Forty cast crowns were fabricated and divided into 4 groups each containing 10 implants. Group A was cemented directly with the definitive cement (Cem-Implant). The remainder were cemented with provisional cement (Temp-Bond NE), and classified according to the method for cleaning the abutments. Group B used a plastic curette and wet gauze, Group C used a rubber cup and pumice, and Group D used an airborne particle abrasion technique. The abutments were observed using a stereomicroscope after removing the provisional cement. The tensile bond strength was measured after the definitive cementation. Statistical analysis was performed using one-way analysis of variance test (α=.05). RESULTS Group B clearly showed provisional cement remaining, whereas the other groups showed almost no cement. Groups A and B showed a relatively smooth surface. More roughness was observed in Group C, and apparent roughness was noted in Group D. The tensile bond strength tests revealed Group D to have significantly the highest tensile bond strength followed in order by Groups C, A and B. CONCLUSION A plastic curette and wet gauze alone cannot effectively remove the residual provisional cement on the abutment. The definitive retention increased when the abutments were treated with rubber cup/pumice or airborne particle abraded to remove the provisional cement. PMID:24049563

  3. Effect of the infrastructure material on the failure behavior of prosthetic crowns.

    PubMed

    Sonza, Queli Nunes; Della Bona, Alvaro; Borba, Márcia

    2014-05-01

    To evaluate the effect of infrastructure (IS) material on the fracture behavior of prosthetic crowns. Restorations were fabricated using a metal die simulating a prepared tooth. Four groups were evaluated: YZ-C, Y-TZP (In-Ceram YZ, Vita) IS produced by CAD-CAM; IZ-C, In-Ceram Zirconia (Vita) IS produced by CAD-CAM; IZ-S, In-Ceram Zirconia (Vita) IS produced by slip-cast; MC, metal IS (control). The IS were veneered with porcelain and resin cemented to fiber-reinforced composite dies. Specimens were loaded in compression to failure using a universal testing machine. The 30° angle load was applied by a spherical piston, in 37°C distilled water. Fractography was performed using stereomicroscope and SEM. Data were statistically analyzed with Anova and Student-Newman-Keuls tests (α=0.05). Significant differences were found between groups (p=0.022). MC showed the highest mean failure load, statistically similar to YZ-C. There was no statistical difference between YZ-C, IZ-C and IZ-S. MC and YZ-C showed no catastrophic failure. IZ-C and IZ-S showed chipping and catastrophic failures. The fracture behavior is similar to reported clinical failures. Considering the ceramic systems evaluated, YZ-C and MC crowns present greater fracture load and a more favorable failure mode than In-Ceram Zirconia crowns, regardless of the fabrication type (CAD-CAM or slip-cast). Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. A quarantine protocol for analysis of returned extraterrestrial samples

    NASA Technical Reports Server (NTRS)

    Bagby, J. R.; Sweet, H. C.; Devincenzi, D. L.

    1983-01-01

    A protocol is presented for the analysis at an earth-orbiting quarantine facility of return samples of extraterrestrial material that might contain (nonterrestrial) life forms. The protocol consists of a series of tests designed to determine whether the sample, conceptualized as a 1-kg sample of Martian soil, is free from nonterrestrial biologically active agents and so may safely be sent to a terrestrial containment facility, or it exhibits biological activity requiring further (second-order) testing outside the biosphere. The first-order testing procedure seeks to detect the presence of any replicating organisms or toxic substances through a series of experiments including gas sampling, analysis of radioactivity, stereomicroscopic inspection, chemical analysis, microscopic examination, the search for metabolic products under growth conditions, microbiologicl assays, and the challenge of cultured cells with any agents found or with the extraterrestrial material as is. Detailed plans for the second-order testing would be developed in response to the actual data received from primary testing.

  5. Accuracy of digital images in the detection of marginal microleakage: an in vitro study.

    PubMed

    Alvarenga, Fábio Augusto; Andrade, Marcelo Ferrarezi; Pinelli, Camila; Rastelli, Alessanda Nara; Victorino, Keli Regina; Loffredo, Leonor de

    2012-08-01

    To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study. Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI). The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99). Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

  6. Stereomicroscopic evaluation of dentinal defects induced by new rotary system: “ProTaper NEXT”

    PubMed Central

    Shori, Deepa Deepak; Shenoi, Pratima Ramakrishna; Baig, Arshia R; Kubde, Rajesh; Makade, Chetana; Pandey, Swapnil

    2015-01-01

    Introduction: The objective of this study was to evaluate dentinal defects formed by new rotary system — Protaper next™ (PTN). Materials and Methods: Sixty single-rooted premolars were selected. All specimens were decoronated and divided into four groups, each group having 15 specimens. Group I specimens were prepared by Hand K-files (Mani), Group II with ProTaper Universal (PT; Dentsply Maillefer), Group III with Hero Shaper (HS; Micro-Mega, Besancon, France), and Group IV with PTN (Dentsply Maillefer). Roots of each specimen were sectioned at 3, 6, and 9mm from the apex and were then viewed under a stereomicroscope to evaluate presence or absence of dentinal defects. Results: In roots prepared with hand files (HFs) showed lowest percentage of dentinal defects (6.7%); whereas in roots prepared with PT, HS, and PTN it was 40, 66.7, and 26.7%, respectively. There was significant difference between the HS group and the PTN group (P < 0.05). Conclusion: All rotary files induced defects in root dentin, whereas the hand instruments induced minimal defects. PMID:26069406

  7. Evaluation of Shear Bond Strength of Orthodontic Brackets Bonded with Nano-Filled Composites

    PubMed Central

    Chalipa, Javad; Akhondi, Mohammad Sadegh Ahmad; Arab, Sepideh; Kharrazifard, Mohammad Javad; Ahmadyar, Maryam

    2013-01-01

    Objectives: The purpose of this study was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Materials and Methods: Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT) was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel) were used in groups II and III respectively. The teeth were stored in distilled water at 37°C for 24 hours, thermocycled in distilled water and debonded with a universal testing machine at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was also evaluated using a stereomicroscope. Results: AELITE Aesthetic Enamel nano-composite revealed a SBS value of 8.44±2.09 MPa, which was higher than Transbond XT (6.91±2.13) and Filtek TM Supreme XT (6.04±2.01). Statistical analysis revealed a significant difference between groups II and III (P < 0.05). No significant difference was found between groups I and III, and between groups I and II (P > 0.05). Evaluation of ARI showed that Transbond XT left fewer adhesive remains on teeth after debonding. Conclusion: Results of this study indicate that the aforementioned nano-composites can be successfully used for bonding orthodontic brackets. PMID:24910655

  8. Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems.

    PubMed

    Bilgin, Mehmet Selim; Erdem, Ali; Dilber, Erhan; Ersoy, İbrahim

    2016-01-01

    The purpose of this study was to compare the fracture resistance of Co-Cr post-cores fabricated with 3 different techniques: traditional casting (TC), computer-aided design and manufacturing (CAD/CAM) milling (CCM) and direct metal laser sintering (DMLS). Forty intact human mandibular premolar were endodontically treated. The roots were then randomly divided into four groups according to the post systems: the control group was only filled with gutta percha. Co-Cr metal posts were fabricated with TC, CCM and DMLS in the other three groups. The posts were luted with a resin cement and subjected to compression test at a crosshead speed of 1mm/min. The statistical analysis of the data was performed using one-way analysis of variance (ANOVA) and multiple comparison post hoc Tukey tests (α=.05). The samples were examined under a stereomicroscope with ×20 magnification for the evaluation of the fracture types. The mean fracture loads were 432.69 N for control, 608.89 N for TC, 689.40 N for DMLS and 959.26 N for CCM. One-way ANOVA revealed significant difference between the groups (p<0.01). In the post hoc Tukey test, there were significant differences between groups except DMLS and TC. While Co-Cr posts fabricated by TC and DMLS systems performed similarly in terms of fracture resistance, posts fabricated by CCM techniques showed higher fracture resistance values. Co-Cr metal posts fabricated by CCM and DMLS could be an alternative to TC processing in daily clinical application. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. [In vitro evaluation of five root canal sealers].

    PubMed

    Testarelli, L; Andreasi Bassi, M; Gambarini, G

    2003-01-01

    An adequate film thickness is an important property of an endodontic sealer, when used in combination with gutta-percha, to eventually fill minimal voids between gutta-percha and the root canal walls, ensuring an hermetic three-dimensional root canal obturation. The goal of the present study was to evaluate the film thickness of the following five root canal sealers: RSA, Rocanal R4, N2, Bioseal and Acroseal. The testing procedures strictly followed ANSI/ADA spec. no. 57 for endodontic filling materials. All root canal sealers were mixed at room temperature strictly following mixing procedures advised by manufacturers. A small amount of sealer was placed between two glass plates and load of 147 N was applied vertically on the top glass plate. After 10 min, the thickness of sealers was measured by a micrometer assembled on a stereomicroscope (Lomo MBC 10). Data were collected and statistically analysed. Results (expressed in micron) were the following: RSA=9,3 (+/-1), Rocanal R4 95 (+/-12), N2 50 (+/-23), Bioseal 41 (+/-13) and Acroseal =9 (+/-2.55). RSA and Acroseal showed the best results (a statistically significant difference was noted among these sealers and the others). On the other hand Bioseal and (partially) N2 showed values compatible with a valid clinical use, while Rocanal R4 showed values higher than minimum standard values allowed by ANSA/ADA spec. no. 57.

  10. To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment.

    PubMed

    Shivanand, Sunita; Patil, Chetan R; Thangala, Venugopal; Kumar, Pabbati Ravi; Sachdeva, Jyoti; Krishna, Akash

    2013-05-01

    To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment. Sixty extracted premolars were retreated with following systems: Group -ProTaper Universal retreatment files, Group 2-ProFile system, Group 3-H-file. Specimens were split longitudinally and amount of remaining gutta-percha on the canal walls was assessed using direct visual scoring with the aid of stereomicroscope. Results were statistically analyzed using ANOVA test. Completely clean root canal walls were not achieved with any of the techniques investigated. However, all three systems proved to be effective for gutta-percha removal. Significant difference was found between ProTaper universal retreatment file and H-file, and also between ProFile and H-file. Under the conditions of the present study, ProTaper Universal retreatment files left significantly less guttapercha and sealer than ProFile and H-file. Rotary systems in combination with gutta-percha solvents can perform superiorly as compared to the time tested traditional hand instrumentation in root canal retreatment.

  11. Comparison of micro push-out bond strengths of two fiber posts luted using simplified adhesive approaches.

    PubMed

    Mumcu, Emre; Erdemir, Ugur; Topcu, Fulya Toksoy

    2010-05-01

    By means of a micro push-out test, this study compared the bond strengths of two types of fiber-reinforced posts cemented with luting cements based on two currently available adhesive approaches as well as evaluated their failure modes. Sixty extracted single-rooted human maxillary central incisor and canine teeth were sectioned below the cementoenamel junction, and the roots were endodontically treated. Following standardized post space preparation, the roots were divided into two fiber post groups and then further into three subgroups of 10 specimens each according to the luting cements. A push-out test was performed to measure regional bond strengths, and the fracture modes were evaluated using a stereomicroscope. At the root section, there were no statistically significant differences (p>0.05) in push-out bond strength among the tested luting cements. Nevertheless, the push-out bond strength values of glass fiber-reinforced posts were higher than those of carbon fiber-reinforced posts, irrespective of the adhesive approach used. On failure mode, the predominant failure mode was adhesive failure between dentin and the luting cement.

  12. Heat treatment of pre-hydrolyzed silane increases adhesion of phosphate monomer-based resin cement to glass ceramic.

    PubMed

    de Carvalho, Rodrigo Furtado; Cotes, Caroline; Kimpara, Estevão Tomomitsu; Leite, Fabíola Pessoa Pereira; Özcan, Mutlu

    2015-01-01

    This study evaluated the influence of different forms of heat treatment on a pre-hydrolyzed silane to improve the adhesion of phosphate monomer-based (MDP) resin cement to glass ceramic. Resin and feldspathic ceramic blocks (n=48, n=6 for bond test, n=2 for microscopy) were randomly divided into 6 groups and subject to surface treatments: G1: Hydrofluoric acid (HF) 9.6% for 20 s + Silane + MDP resin cement (Panavia F); G2: HF 9.6% for 20 s + Silane + Heat Treatment (oven) + Panavia F; G3: Silane + Heat Treatment (oven) + Panavia F; G4: HF 9.6% for 20 s + Silane + Heat Treatment (hot air) + Panavia F; G5: Silane + Heat Treatment (hot air) + Panavia F; G6: Silane + Panavia F. Microtensile bond strength (MTBS) test was performed using a universal testing machine (1 mm/min). After debonding, the substrate and adherent surfaces were analyzed using stereomicroscope and scanning electron microscope (SEM) to categorize the failure types. Data were analyzed statistically using two-way test ANOVA and Tukey's test (=0.05). Heat treatment of the silane containing MDP, with prior etching with HF (G2: 13.15 ± 0.89a; G4: 12.58 ± 1.03a) presented significantly higher bond strength values than the control group (G1: 9.16 ± 0.64b). The groups without prior etching (G3: 10.47 ± 0.70b; G5: 9.47 ± 0.32b) showed statistically similar bond strength values between them and the control group (G1). The silane application without prior etching and heat treatment resulted in the lowest mean bond strength (G6: 8.05 ± 0.37c). SEM analysis showed predominantly adhesive failures and EDS analysis showed common elements of spectra (Si, Na, Al, K, O, C) characterizing the microstructure of the glass-ceramic studied. Heat treatment of the pre-hydrolyzed silane containing MDP in an oven at 100 °C for 2 min or with hot air application at 50 ± 5 ºC for 1 min, was effective in increasing the bond strength values between the ceramic and resin cement containing MDP.

  13. Comparative Evaluation of Marginal Adaptation and Fracture Strength of Different Ceramic Inlays Produced by CEREC Omnicam and Heat-Pressed Technique.

    PubMed

    Oz, F D; Bolay, S

    2018-01-01

    The aim of this in vitro study was to evaluate marginal adaptation and fracture strength of inlays produced by CEREC Omnicam using different types of blocs and heat-pressed technique. Methods: Seventy-five extracted human mandibular molars were divided randomly into 5 groups ( n =15). 60 molars in four groups received MOD inlay preparations. Experimental groups were CO: Intact teeth, EC: IPS e.max CAD and CEREC, LU: Lava Ultimate and CEREC, EL: IPS Empress CAD and CEREC, EP: IPS Empress Esthetic ingots and heat-pressed technique. Marginal gap measurements were taken with a stereomicroscope. Restorations were cemented with Variolink N and stored in distilled water at 37°C for 24 hours. All samples were subjected to thermocycling. The fracture strength of specimens was determined at a 0.5 mm/min crosshead speed until fracture. Fracture modes were determined. Statistical analyses were performed using one-way analysis of variance for fracture strength data and Kruskal-Wallis for marginal gap data ( p =0.05). The mean marginal gap size of EC, LU, EL, and EP were 33.54  µ m, 33.77  µ m, 34.23  µ m, and 85.34  µ m, respectively. EP had statistically higher values than other groups. The fracture strength values were significantly higher in the intact teeth group (3959,00 ± 1279,79 N) than those of restored groups EC (2408,00 ± 607,97 N), LU (2206,73 ± 675,16), EL (2573.27 ± 644,73) ve EP (2879,53 ± 897,30). Inlays fabricated using CEREC Omnicam demonstrated better marginal adaptation than inlays produced with heat-pressed technique, whereas fracture strength values of inlays fabricated with different type of blocks using CEREC Omnicam exhibited similarity to those fabricated with heat-pressed technique.

  14. Comparative Evaluation of Marginal Adaptation and Fracture Strength of Different Ceramic Inlays Produced by CEREC Omnicam and Heat-Pressed Technique

    PubMed Central

    Bolay, S.

    2018-01-01

    Objective The aim of this in vitro study was to evaluate marginal adaptation and fracture strength of inlays produced by CEREC Omnicam using different types of blocs and heat-pressed technique. Methods: Seventy-five extracted human mandibular molars were divided randomly into 5 groups (n=15). 60 molars in four groups received MOD inlay preparations. Experimental groups were CO: Intact teeth, EC: IPS e.max CAD and CEREC, LU: Lava Ultimate and CEREC, EL: IPS Empress CAD and CEREC, EP: IPS Empress Esthetic ingots and heat-pressed technique. Marginal gap measurements were taken with a stereomicroscope. Restorations were cemented with Variolink N and stored in distilled water at 37°C for 24 hours. All samples were subjected to thermocycling. The fracture strength of specimens was determined at a 0.5 mm/min crosshead speed until fracture. Fracture modes were determined. Statistical analyses were performed using one-way analysis of variance for fracture strength data and Kruskal–Wallis for marginal gap data (p=0.05). Results The mean marginal gap size of EC, LU, EL, and EP were 33.54 µm, 33.77 µm, 34.23 µm, and 85.34 µm, respectively. EP had statistically higher values than other groups. The fracture strength values were significantly higher in the intact teeth group (3959,00 ± 1279,79 N) than those of restored groups EC (2408,00 ± 607,97 N), LU (2206,73 ± 675,16), EL (2573.27 ± 644,73) ve EP (2879,53 ± 897,30). Conclusion Inlays fabricated using CEREC Omnicam demonstrated better marginal adaptation than inlays produced with heat-pressed technique, whereas fracture strength values of inlays fabricated with different type of blocks using CEREC Omnicam exhibited similarity to those fabricated with heat-pressed technique. PMID:29853894

  15. Effect of 5% Chlorine Dioxide Irrigant on Micro Push Out Bond Strength of Resin Sealer to Radicular Dentin: An In Vitro Study

    PubMed Central

    Devarasanahalli, Swapna V; Aswathanarayana, Ranjini M; Rashmi, K; Gowda, Yashwanth; Nadig, Roopa R

    2017-01-01

    Introduction Chlorine dioxide (ClO2) has been recently investigated as a possible root canal irrigant due to its broad spectrum of antimicrobial action, tissue dissolution and smear layer removal properties. Literature is scarce on the effect of chlorine dioxide irrigation on the resin sealer dentin bond strength. Aim To compare 5% chlorine dioxide (ClO2) with or without Ethylene Diamine Tetra Acetic acid (EDTA) with 3% Sodium hypochlorite (NaOCl) and EDTA combination as endodontic irrigants on the adhesion of AH Plus sealer to radicular dentin using micro- Push out Bond Strength (µPBS) test. Materials and Methods Forty freshly extracted central incisors were decoronated and randomly divided into four groups based on the different irrigation regimes followed during irrigation: Group I - 3% NaOCl + 17% EDTA, Group II - 5% ClO2 + 17% EDTA, Group III - 5% ClO2 and Group IV – Saline, and canal enlarged till Protaper F3. All the samples were obturated with F3 gutta-percha cones using AH Plus sealer and sectioned perpendicular to long axis to obtain 1mm thick slices from the middle and coronal portions for µPBS measurement in universal testing machine followed by assessment of failure pattern under stereomicroscope. Data was analysed using One-way analysis of variance (ANOVA), Bonferroni and t-test. Results Bond strength values were in the following order: Group I>Group II>Group III>Group IV, with no statistically significant difference amongst experimental groups on intergroup comparison, except with saline. The µPBS values were more in coronal third than middle third in all specimens, with no statistical significant difference. Mode of failure showed mixed patterns in all experimental groups except saline. Conclusion In the present study, the bond strength values of ClO2 were comparable with conventional NaOCl and EDTA combination and hence, ClO2 can be considered as an effective alternative endodontic irrigant. PMID:28658907

  16. Differentiation between primary and secondary Raynaud's phenomenon: a prospective study comparing nailfold capillaroscopy using an ophthalmoscope or stereomicroscope

    PubMed Central

    Anders, H; Sigl, T; Schattenkirchner, M

    2001-01-01

    BACKGROUND—Nailfold capillary microscopy is a routine procedure in the investigation of patients with Raynaud's phenomenon (RP). As a standard method, nailfold capillary morphology is inspected with a stereomicroscope to look for capillary abnormalities such as giant loops, avascular areas, and bushy capillaries, which have all been found to be associated with certain connective tissue diseases.
AIM—To investigate prospectively whether nailfold capillary inspection using an ophthalmoscope is of equivalent diagnostic value to standard nailfold capillary microscopy.
METHOD—All the fingers of 26 patients with RP were examined in a blinded fashion and compared with the final diagnosis one month later.
RESULTS—All giant loops, large avascular areas, and bushy capillaries were identified by both methods. The correlation for moderate avascular areas and crossed capillaries was 0.93 and 0.955 respectively. The correlation for minor abnormalities that do not contribute to the differentiation between primary and secondary RP was 0.837 and 0.861 respectively. All patients were classified identically by the two methods.
CONCLUSION—For the evaluation of patients with RP, nailfold capillary morphology can reliably be assessed with an ophthalmoscope.

 PMID:11247874

  17. Comparative evaluation of microleakage of lingual retainer wires bonded with three different lingual retainer composites: an in vitro study.

    PubMed

    Nimbalkar-Patil, Smita; Vaz, Anna; Patil, Pravinkumar G

    2014-11-01

    To evaluate microleakage when two types of retainer wires were bonded with two light cured and a self cured lingual retainer composites. Total 120 freshly extracted human mandibular incisor teeth were collected and separated into six subgroups of 20 teeth each. Two different wires, a 0.036 inch hard round stainless steel (HRSS) wire sandblasted at the ends and 0.0175 inch multistranded wire bonded onto the lingual surfaces of the incisors with three different types of composite resins of 3M company; Concise Orthodontic (self-cure), Transbond XT (light-cure) and Transbond LR (light-cure). Specimens were further sealed with a nail varnish, stained with 0.5% basic fuchsine for 24 hours, sectioned and examined under a stereomicroscope, and scored for microleakage for the enamel-composite and wire-composite interfaces. Statistical analysis was performed by Kruskal-Wallis and Mann-Whitney U-tests. For HRSS wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT (p<0.05). At the wire composite interface too, the microleakage was in order of Transbond LR

  18. Mixing with propylene glycol enhances the bond strength of mineral trioxide aggregate to dentin.

    PubMed

    Salem Milani, Amin; Froughreyhani, Mohammad; Charchi Aghdam, Saeed; Pournaghiazar, Fatemeh; Asghari Jafarabadi, Mohammad

    2013-11-01

    Mixing mineral trioxide aggregate (MTA) with different proportions of propylene glycol (PG) improves its handling property. The aim of this study was to evaluate the effect of PG on MTA-dentin push-out bond strength. Seventy-five 2-mm-thick midroot sections were prepared from single-rooted human extracted teeth. The lumen of each slice was enlarged with Gates-Glidden burs. The slices were randomly divided into 3 groups (n = 25). In each group, 0.3 mL of the liquid was mixed with 1 g MTA (Angelus, Londrina, Brazil). The liquid vehicles used in groups 1-3 were 100% distilled water (DW), 20% PG-80% DW, and 100% PG, respectively. After incubation, the push-out strength of the samples was measured using a universal testing machine. The samples were then cut in halves and examined under a stereomicroscope to determine the failure pattern. One-way analysis of variance followed by the Tukey post hoc test was used to compare the push-out strength among groups. There were statistically significant differences between groups (P < .001). The push-out strength in group 1 (DW) was significantly lower than groups 2 and 3 (P < .001 and P = .022, respectively). However, there was no significant difference between groups 2 (DW-PG) and 3 (PG). Mixing MTA with PG increased its push-out bond strength to dentin. In the present study, the most suitable ratio was 80% DW-20% PG. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

    PubMed

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.

  20. Evaluation of isthmus prevalence, location, and types in mesial roots of mandibular molars in the Iranian Population

    PubMed Central

    Mehrvarzfar, Payman; Akhlagi, Nahid Mohammadzade; Khodaei, Fatemeh; Shojaee, Golnaz; Shirazi, Sara

    2014-01-01

    Background: Management of canal isthmus is considered as an important factor for successful endodontic treatment. Accordingly, this study was designed to determine the prevalence, location, and types of isthmus in mesial root canals of extracted mandibular molars in a sample of Iranian population. Materials and Methods: In this cross-sectional descriptive study, 60 extracted molars with two mesial canals were included. The samples were initially decoronated and then, roots were sectioned horizontally at 2, 4, and 6 mm levels from the apex via a low-speed handpiece with a thin metallic disk and finally prepared and stained with Indian ink. All sections were examined using a stereomicroscope at a magnification of ×30. Prevalence, location, and types of isthmus were evaluated based on the classifications by Kim and Teixeira and all data were statistically analyzed by the chi-squared test. The statistical significance level was established at 0.05. Results: Eighty-three percent of extracted mandibular molars had an isthmus at the mesial root. This prevalence increased with distance from the apex, that is, 92% at 6 mm from the apex and 70% at 2 mm from the apex. A statistically significant difference was found between the sections at 2 and 6 mm from the apex (P < 0.05), but no other significant differences between other levels (P > 0.05). Conclusion: Isthmus is very common in the mesial roots of the mandibular permanent molars in the Iranian population, with the highest prevalence in the 6 mm distance from the root apex. Therefore, detection, cleaning, and filling of these apical 6 mm isthmuses are of great benefit in modern endodontics. PMID:24932198

  1. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis

    PubMed Central

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-01-01

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297

  2. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis.

    PubMed

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-12-16

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world.

  3. Anthropogenic microfibres pollution in marine biota. A new and simple methodology to minimize airborne contamination.

    PubMed

    Torre, Michele; Digka, Nikoletta; Anastasopoulou, Aikaterini; Tsangaris, Catherine; Mytilineou, Chryssi

    2016-12-15

    Research studies on the effects of microlitter on marine biota have become more and more frequent the last few years. However, there is strong evidence that scientific results based on microlitter analyses can be biased by contamination from air transported fibres. This study demonstrates a low cost and easy to apply methodology to minimize the background contamination and thus to increase results validity. The contamination during the gastrointestinal content analysis of 400 fishes was tested for several sample processing steps of high risk airborne contamination (e.g. dissection, stereomicroscopic analysis, and chemical digestion treatment for microlitter extraction). It was demonstrated that, using our methodology based on hermetic enclosure devices, isolating the working areas during the various processing steps, airborne contamination reduced by 95.3%. The simplicity and low cost of this methodology provide the benefit that it could be applied not only to laboratory but also to field or on board work. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Adhesive performance of precoated brackets after expiration.

    PubMed

    Cloud, Cayce C; Trojan, Terry M; Suliman, Sam N; Tantbirojn, Daranee; Versluis, Antheunis

    2016-03-01

    To evaluate adhesive performance in terms of debonding forces of precoated metal and ceramic brackets 4 years after expiration. Buccal and lingual surfaces of embedded extracted maxillary premolars were etched with 34% Tooth Conditioner Gel (Dentsply Caulk, Milford, Del), rinsed, and dried. Transbond MIP (3M Unitek, Monrovia, Calif) was applied prior to placing adhesive precoated brackets (APC II Victory stainless steel and APC Plus Clarity ceramic brackets, 3M Unitek). The preexpiration brackets had 29-35 months before, and the postexpiration brackets were 45-52 months past, their expiration dates. Sample size was 17-21 per group. Debonding forces were determined by subjecting the bonded brackets to a shear force in a universal testing machine. Debonding forces were compared using two-way ANOVA. Debonded surfaces were examined under a stereomicroscope to determine failure modes, which were compared using the chi-square test. No statistically significant difference was found in debonding forces (P  =  .8581) or failure modes (P  =  .4538) between expired and unexpired brackets. Metal brackets required statistically significantly higher debonding forces than did ceramic brackets (P  =  .0001). For both expired and unexpired brackets, failure modes were mostly cohesive in the adhesive layer for ceramic brackets, and mixed between adhesive and cohesive failure in the adhesive layer for metal brackets. Adhesive precoated brackets did not have any reduction in enamel-adhesion properties up to 4 years after their expiration date. Extended shelf life testing for precoated dental brackets may be worth considering.

  5. Comparison of Shear Bond Strength of RMGI and Composite Resin for Orthodontic Bracket Bonding

    PubMed Central

    Yassaei, Soghra; Davari, Abdolrahim; Goldani Moghadam, Mahjobeh; Kamaei, Ahmad

    2014-01-01

    Objective: The aim of this study was to compare the shear bond strength (SBS) of resin modified glass ionomer (RMGI) and composite resin for bonding metal and ceramic brackets. Materials and Methods: Eighty-eight human premolars extracted for orthodontic purposes were divided into 4 groups (n=22). In groups 1 and 2, 22 metal and ceramic brackets were bonded using composite resin (Transbond XT), respectively. Twenty-two metal and ceramic brackets in groups 3 and 4, respectively were bonded using RMGI (Fuji Ortho LC, Japan). After photo polymerization, the teeth were stored in water and thermocycled (500 cycles between 5° and 55°). The SBS value of each sample was determined using a Universal Testing Machine. The amount of residual adhesive remaining on each tooth was evaluated under a stereomicroscope. Statistical analyses were done using two-way ANOVA. Results: RMGI bonded brackets had significantly lower SBS value compared to composite resin bonded groups. No statistically significant difference was observed between metal and ceramic brackets bonded with either the RMGI or composite resin. The comparison of the adhesive remnant index (ARI) scores between the groups indicated that the bracket failure mode was significantly different among groups (P<0.001) with more adhesive remaining on the teeth bonded with composite resin. Conclusion: RMGIs have significantly lower SBS compared to composite resin for orthodontic bonding purposes; however the provided SBS is still within the clinically acceptable range. PMID:25628663

  6. Polymerization shrinkage of different types of composite resins and microleakage with and without liner in class II cavities.

    PubMed

    Karaman, E; Ozgunaltay, G

    2014-01-01

    To determine the volumetric polymerization shrinkage of four different types of composite resin and to evaluate microleakage of these materials in class II (MOD) cavities with and without a resin-modified glass ionomer cement (RMGIC) liner, in vitro. One hundred twenty-eight extracted human upper premolar teeth were used. After the teeth were divided into eight groups (n=16), standardized MOD cavities were prepared. Then the teeth were restored with different resin composites (Filtek Supreme XT, Filtek P 60, Filtek Silorane, Filtek Z 250) with and without a RMGIC liner (Vitrebond). The restorations were finished and polished after 24 hours. Following thermocycling, the teeth were immersed in 0.5% basic fuchsin for 24 hours, then midsagitally sectioned in a mesiodistal plane and examined for microleakage using a stereomicroscope. The volumetric polymerization shrinkage of materials was measured using a video imaging device (Acuvol, Bisco, Inc). Data were statistically analyzed with Kruskal-Wallis and Mann-Whitney U-tests. All teeth showed microleakage, but placement of RMGIC liner reduced microleakage. No statistically significant differences were found in microleakage between the teeth restored without RMGIC liner (p>0.05). Filtek Silorane showed significantly less volumetric polymerization shrinkage than the methacrylate-based composite resins (p<0.05). The use of RMGIC liner with both silorane- and methacrylate-based composite resin restorations resulted in reduced microleakage. The volumetric polymerization shrinkage was least with the silorane-based composite.

  7. The Comparative Efficacy of Different Files in The Removal of Different Sealers in Simulated Root Canal Retreatment- An In-vitro Study.

    PubMed

    Kanaparthy, Aruna; Kanaparthy, Rosaiah

    2016-05-01

    Root canal treatment enjoys a high success rate all over the world and has saved billions of teeth from extraction. However, there are instances of failure, the main causes being insufficient cleaning and inadequate obturation. In such cases the most conservative treatment option would be non-surgical retreatment. It requires regaining access to the entire root canal system through removal of the original root canal filling thus permitting further cleaning and re- obturation. Removal of gutta-percha and sealer becomes a critical step to gain access to the root canal system, remove necrotic tissue debris, bacteria and infected dentin. To compare and evaluate the efficacy of manual hand Hedstrom files and two rotary retreatment file systems ProTaper Universal retreatment files and Mtwo(R) (retreatment) files in the removal of root canal filling material during root canal retreatment and the influence of the type of sealers zinc oxide eugenol and AH plus on the presence of remaining debris in the reinstrumented canals in the apical, middle and coronal third. Sixty single rooted human premolar teeth were divided into 3 Groups of 20 teeth each Group I (20 Teeth): prepared using hand K Files, Group II (20 Teeth): prepared using ProTaper rotary system and Group III (20 Teeth): prepared using Mtwo rotary system. In Groups- IA, IIA, IIIA: (10 teeth each) Obturation was done using Zinc Oxide Eugenol sealer and gutta percha. In Groups- IB, IIB, IIIB: (10 teeth each) obturation was done with AH Plus sealer and gutta percha. All the teeth were subjected to retreatment. Groups IA and IB with Hedstrom files, Groups IIA and IIB with ProTaper retreatment files and for Groups IIIA and IIIB with Mtwo retreatment Files. The roots were longitudinally split and were observed under a stereomicroscope for remaining amount of filling material on the canal walls. Statistical analysis was done using One-way ANOVA (Analysis of variance) test and Tukey HSD Test. Mtwo(R) files showed statistically significant difference in the removal of filling material in the apical third and ProTaper R in the coronal and apical thirds. Better cleaning efficacy was seen in canals obturated with zinc oxide eugenol sealer. Mtwo(R) files showed better removal of filling material than ProTaper R followed by Hedstrom files, even though there was no statistically significant difference. None of the instrument group showed complete removal of the filling material. It was easier to remove zinc oxide eugenol sealer than AH plus sealer.

  8. Experimenting with a Visible Copper-Aluminum Displacement Reaction in Agar Gel and Observing Copper Crystal Growth Patterns to Engage Student Interest and Inquiry

    ERIC Educational Resources Information Center

    Xu, Xinhua; Wu, Meifen; Wang, Xiaogang; Yang, Yangyiwei; Shi, Xiang; Wang, Guoping

    2016-01-01

    The reaction process of copper-aluminum displacement in agar gel was observed at the microscopic level with a stereomicroscope; pine-like branches of copper crystals growing from aluminum surface into gel at a constant rate were observed. Students were asked to make hypotheses on the pattern formation and design new research approaches to prove…

  9. Effect of Anatomical Customization of the Fiber Post on the Bond Strength of a Self-Adhesive Resin Cement.

    PubMed

    Rocha, Adricyla Teixeira; Gonçalves, Leticia Machado; Vasconcelos, Ana Júlia de Carvalho; Matos Maia Filho, Etevaldo; Nunes Carvalho, Ceci; De Jesus Tavarez, Rudys Rodolfo

    2017-01-01

    The aim of the study was to evaluate, by means of the push-out test, the effect of the anatomical customization of the fiber post on the bond strength of a self-adhesive resin cement. Twelve endodontically treated, human, upper central incisors were randomly divided into two groups ( n = 6): control (glass fiber posts cemented with Relyx® U200) and customized (glass fiber posts anatomically customized with translucent composite resin cemented with Relyx U200). The roots were sectioned into three slices, cervical, middle, and apical, and photographed with a digital camera attached to a stereomicroscopic loupe. The images were analyzed by software, for evaluation of the cement line. The slices were subsequently submitted to the push-out test until the post had completely extruded, and the fracture mode was analyzed with a stereomicroscopic loupe. The results showed significant differences between the groups in the different root thirds in relation to the area occupied by air bubbles ( p < 0.05). Bond strength, when all the thirds are considered, was 8.77 ± 4.89 MPa for the control group and 16.96 ± 4.85 MPa for the customized group. The customized group showed greater bond resistance than the control group and a more uniform cement layer.

  10. Fiber optics welder having movable aligning mirror

    DOEpatents

    Higgins, Robert W.; Robichaud, Roger E.

    1981-01-01

    A system for welding fiber optic waveguides together. The ends of the two fibers to be joined together are accurately, collinearly aligned in a vertical orientation and subjected to a controlled, diffuse arc to effect welding and thermal conditioning. A front-surfaced mirror mounted at a 45.degree. angle to the optical axis of a stereomicroscope mounted for viewing the junction of the ends provides two orthogonal views of the interface during the alignment operation.

  11. Fiber optics welder

    DOEpatents

    Higgins, R.W.; Robichaud, R.E.

    A system is described for welding fiber optic waveguides together. The ends of the two fibers to be joined together are accurately, collinearly aligned in a vertical orientation and subjected to a controlled, diffuse arc to effect welding and thermal conditioning. A front-surfaced mirror mounted at a 45/sup 0/ angle to the optical axis of a stereomicroscope mounted for viewing the junction of the ends provides two orthogonal views of the interface during the alignment operation.

  12. Shear Bond Strengths between Three Different Yttria-Stabilized Zirconia Dental Materials and Veneering Ceramic and Their Susceptibility to Autoclave Induced Low-Temperature Degradation.

    PubMed

    Sehgal, Manoti; Bhargava, Akshay; Gupta, Sharad; Gupta, Prateek

    2016-01-01

    A study was undertaken to evaluate the effect of artificial aging through steam and thermal treatment as influencing the shear bond strength between three different commercially available zirconia core materials, namely, Upcera, Ziecon, and Cercon, layered with VITA VM9 veneering ceramic using Universal Testing Machine. The mode of failure between zirconia and ceramic was further analyzed as adhesive, cohesive, or mixed using stereomicroscope. X-ray diffraction and SEM (scanning electron microscope) analysis were done to estimate the phase transformation (m-phase fraction) and surface grain size of zirconia particles, respectively. The purpose of this study was to simulate the clinical environment by artificial aging through steam and thermal treatment so as the clinical function and nature of the bond between zirconia and veneering material as in a clinical trial of 15 years could be evaluated.

  13. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation – An In vitro Study

    PubMed Central

    Mahesh, MC; Bhandary, Shreetha

    2017-01-01

    Introduction Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. Aim This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. Materials and Methods In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Results Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). Conclusion There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels. PMID:28274036

  14. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation - An In vitro Study.

    PubMed

    Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha

    2017-01-01

    Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels.

  15. Effect of ultrasonic tip and root-end filling material on bond strength.

    PubMed

    Vivan, Rodrigo Ricci; Guerreiro-Tanomaru, Juliane Maria; Bernardes, Ricardo Affonso; Reis, José Mauricio Santos Nunes; Hungaro Duarte, Marco Antonio; Tanomaru-Filho, Mário

    2016-11-01

    The objective of this study was to evaluate the bond strength of three root-end filling materials (MTAA-MTA Angelus, MTAS-experimental MTA Sealer, and ZOE- zinc oxide and eugenol cement) in retrograde preparations performed with different ultrasonic tips (CVD, Trinity, and Satelec). Ninety 2-mm root sections from single-rooted human teeth were used. The retrograde cavities were prepared by using the ultrasonic tips, coupled to a device for position standardization. The specimens were randomly divided into nine groups: CVD MTAA; CVD MTAS; CVD ZOE; Trinity MTAA; Trinity MTAS; Trinity ZOE; Satelec MTAA; Satelec MTAS; Satelec ZOE. Each resin disc/dentin/root-end filling material was placed in the machine to perform the push-out test. The specimens were examined in a stereomicroscope to evaluate the type of failure. Data were submitted to statistical analysis using ANOVA and Tukey tests (α = 0.05). The highest bond strength was observed for the CVD tip irrespective of the material used (P < 0.05). There was no significant difference for the Trinity TU-18 diamond and S12 Satelec tips (P > 0.05). MTAA and MTAS showed highest bond strength. The most common type of failure was adhesion between the filling material and dentin wall, except for ZOE, where mixed failure was predominant. The CVD tip favored higher bond strength of the root-end filling materials. MTA Angelus and experimental MTAS presented bond strength to dentin prepared with ultrasonic tips. Root-end preparation with the CVD tip positively influences the bond strength of root-end filling materials. MTA Angelus and experimental MTAS present bond strength to be used as root-end filling materials.

  16. Effect of surface treatments on the flexural properties and adhesion of glass fiber-reinforced composite post to self-adhesive luting agent and radicular dentin.

    PubMed

    Elnaghy, Amr M; Elsaka, Shaymaa E

    2016-01-01

    This study evaluated the effect of different surface treatments on the flexural properties and adhesion of glass fiber post to self-adhesive luting agent and radicular dentin. Seventy-five single-rooted human teeth were prepared to receive a glass fiber post (Reblida). The posts were divided into five groups according to the surface treatment: Gr C (control; no treatment), Gr S (silanization for 60 s), Gr AP (airborne-particle abrasion), Gr HF (etching with 9 % hydrofluoric acid for 1 min), and Gr M10 (etching with CH2Cl2 for 10 min). Dual-cure self-adhesive luting agent (Rely X Unicem) was applied to each group for testing the adhesion using micropush-out test. Failure types were examined with stereomicroscope and surface morphology of the posts was characterized using a scanning electron microscopy (SEM). Flexural properties of posts were assessed using a three-point bending test. Data were analyzed using ANOVA and Tukey's HSD test. Statistical significance was set at the 0.05 probability level. Groups treated with M10 showed significantly higher bond strength than those obtained with other surface treatments (P < 0.05). In general, improvements in bond strength (MPa) were found in the following order: M10 > C > S > AP > HF. Most failure modes were adhesive type of failures between dentin and luting agent (48.2%). SEM analysis revealed that the fiber post surfaces were modified after surface treatments. The surface treatments did not compromise the flexural properties of fiber posts. Application of M10 to the fiber post surfaces enhanced the adhesion to self-adhesive luting agent and radicular dentin.

  17. Evaluation of Microtensile Bond Strength and Microleakage of a Self-adhering Flowable Composite.

    PubMed

    Yuan, He; Li, Mingyang; Guo, Bin; Gao, Yuan; Liu, HongLing; Li, Jiyao

    2015-12-01

    To evaluate the microtensile bond strength (μTBS) and marginal sealing ability of a self-adhering flowable composite between dentin and composite interfaces, as well as the microleakage of Class V restorations. The occlusal thirds of 40 third molars were removed and randomly divided into 4 groups according to the applied adhesive: Adper Easy One (AEO, 3M ESPE), Clearfil SE Bond (CSEB, Kuraray), Prime & Bond NT (PBNT, Dentsply) and a self-adhering flowable composite (Dyad Flow, DF, Kerr). Filtek Flowable (3M ESPE) resin composite crowns were then built up in the first three groups; in group DF, composite crowns were built up without the application of an adhesive. Thirty stick-shaped microspecimens were prepared per group, 10 of which were used for morphological observation of bonded interfaces by scanning electron microscopy (SEM) after decalcification. The remaining microspecimens underwent microtensile bond strength testing and the failure mode was analyzed. Microleakage evaluation was performed on 10 premolars per group in which standardized box-shaped Class V cavities were prepared. After 500 thermocycles, the premolars were immersed in 1% methylene blue for 24 h, and three slices from each tooth were observed under a stereomicroscope and scored. Statistical analysis was performed using one-way ANOVA, Student-Newman-Keuls and chi-square tests. The PBNT group presented the highest μTBS values, followed by the CSEB and AEO groups, which did not differ significantly from each other. The DF group showed the lowest μTBS values. No significant differences in microleakage were observed among these four groups. Although individual usage of the self-adhering flowable composite showed the lowest bond strength, the same marginal sealing ability was observed as that of combining self-etching and etch-and-rinse adhesives with flowable composite.

  18. Influence of finish line on the marginal seal of nanohybrid composite crowns after periodontal scaling: a microleakage study.

    PubMed

    Angerame, D; De Biasi, M; Del Lupo, V; Bevilacqua, L; Zarone, F; Sorrentino, R

    2015-10-01

    The aim of the present microleakage study was to assess the sealing ability of nanohybrid composite crowns with different finish lines exposed to simulated mechanical periodontal treatment (SMPT). After sample size calculation (α=0.05; β=0.20; δ=1.0; σ=0.8), sixty extracted mandibular molars were divided into four groups (N.=15): G1, 90° shoulder; G2, beveled 90° shoulder; G3, 90° shoulder and SMPT; G4, beveled 90° shoulder and SMPT. Tooth preparations were carried out by means of diamond burs and Arkansas stones. The buildup of crowns was performed with a nanohybrid composite on master casts obtained after polyether impressions and crowns were cemented with self-adhesive cement. Groups G3 and G4 were subjected to the equivalent of five years of semestral mechanical periodontal scaling with Gracey curettes (2-mm long strokes, 5 N). Samples were immersed into a methylene blue supersaturated solution for 10 minutes. Microleakage was measured by stereomicroscopic observation of multiple sections of the samples and leakage data underwent statistical analysis with non-parametric tests. Marginal microleakage was 1.53±1.27% and 17.60±12.72% of the length of the adhesive interface in G1 and G2, respectively. SMPT reduced dye penetration (P<0.001) with G3 not leaking at all and G4 leaking along the 5.58±1.84% of the adhesive interface. The bevel preparation significantly worsened the marginal seal both in control and treated crowns (P<0.001). Microleakage of nanohybrid composite crowns increased by adding a bevel to a 90° shoulder preparation and diminished after SMPT.

  19. Comparative Evaluation of Two Final Irrigation Techniques for the Removal of Precipitate Formed by the Interaction between Sodium Hypochlorite and Chlorhexidine.

    PubMed

    Metri, Malasiddappa; Hegde, Swaroop; Dinesh, K; Indiresha, H N; Nagaraj, Shruthi; Bhandi, Shilpa H

    2015-11-01

    To evaluate the effectiveness of two final irrigation techniques for the removal of precipitate formed by the interaction between sodium hypochlorite (NaOCl) and chlorhexidine (CHX). Sixty freshly extracted human maxillary incisor teeth were taken and randomly divided into three groups, containing 20 teeth each. Group 1 (control group), were irrigated with 5 ml of 2.5% NaOCl and a final flush with 5 ml of 2% chlorhexidine. Group 2 were irrigated with 5 ml of 2.5% NaOCl and 5 ml of 2% chlorhexidine followed by 5 ml of saline and agitated with F-files. Group 3 were irrigated with 5 ml of 2.5% NaOCl and 5 ml of 2% chlorhexidine followed by 5 ml of 15% citric acid and passively agitated with ultrasonics. A thin longitudinal groove was made along the buccal and lingual aspect of the root using diamond disks and split with chisel and mallet. Both halves of the split tooth will be examined under stereomicroscope. Results were tabulated and analyzed statistically using analysis of variance (ANOVA) and Mann-Whitney U test. There was a significant difference between the mean values (p < 0.05) in groups 2 and 3 compared to group 1 at each level. Passive ultrasonic irrigation is more effective than the F-file agitation technique to remove the precipitate at all three levels measured. Combination of sodium hypochlorite and chlorhexidine irrigation protocol has been practiced since from many years to achieve good results. However, it has adverse effect in the form of precipitate and which is considered to be a carcinogenic in nature, hence this precipitate should be removed.

  20. In vitro evaluation of casein phosphopeptide-amorphous calcium phosphate effect on the shear bond strength of dental adhesives to enamel.

    PubMed

    Shadman, Niloofar; Ebrahimi, Shahram Farzin; Shoul, Maryam Azizi; Sattari, Hasti

    2015-01-01

    Casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) is applied for remineralization of early caries lesions or tooth sensitivity conditions and may affect subsequent resin bonding. This in vitro study investigated the effect of CPP-ACP on the shear bond strength of dental adhesives to enamel. Sixty extracted human molar teeth were selected and randomly divided into three groups and six subgroups. Buccal or lingual surfaces of teeth were prepared to create a flat enamel surface. Adhesives used were Tetric N-Bond, AdheSE and AdheSE One F. In three subgroups, before applying adhesives, enamel surfaces were treated with Tooth Mousse CPP-ACP for one hour, rinsed and stored in 37°C temperature with 100% humidity. This procedure was repeated for 5 days and then adhesives were applied and Tetric N-Ceram composite was adhered to the enamel. This procedure was also fulfilled for the other three subgroups without CPP-ACP treatment. After 24 hour water storage, samples were tested for shear bond strength test in a universal testing machine. Failure modes were determined by stereomicroscope. Data were analyzed by t-test and one-way analysis of variance with P < 0.05 as the level of significance. In comparison between applied and non-applied CPP-ACP subgroups, there was no significant decrease in the shear bond strength to enamel only in Tetric N-Bond (P > 0.05). In non-applied CPP-ACP subgroups, there were statistically significant differences among all subgroups. Tetric N-Bond had the highest and AdheSE One F had the lowest shear bond strength. CPP-ACP application reduces the shear bond strength of AdheSE and AdheSE One F to enamel but not Tetric N-Bond.

  1. In vitro evaluation of casein phosphopeptide-amorphous calcium phosphate effect on the shear bond strength of dental adhesives to enamel

    PubMed Central

    Shadman, Niloofar; Ebrahimi, Shahram Farzin; Shoul, Maryam Azizi; Sattari, Hasti

    2015-01-01

    Background: Casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) is applied for remineralization of early caries lesions or tooth sensitivity conditions and may affect subsequent resin bonding. This in vitro study investigated the effect of CPP-ACP on the shear bond strength of dental adhesives to enamel. Materials and Methods: Sixty extracted human molar teeth were selected and randomly divided into three groups and six subgroups. Buccal or lingual surfaces of teeth were prepared to create a flat enamel surface. Adhesives used were Tetric N-Bond, AdheSE and AdheSE One F. In three subgroups, before applying adhesives, enamel surfaces were treated with Tooth Mousse CPP-ACP for one hour, rinsed and stored in 37°C temperature with 100% humidity. This procedure was repeated for 5 days and then adhesives were applied and Tetric N-Ceram composite was adhered to the enamel. This procedure was also fulfilled for the other three subgroups without CPP-ACP treatment. After 24 hour water storage, samples were tested for shear bond strength test in a universal testing machine. Failure modes were determined by stereomicroscope. Data were analyzed by t-test and one-way analysis of variance with P < 0.05 as the level of significance. Results: In comparison between applied and non-applied CPP-ACP subgroups, there was no significant decrease in the shear bond strength to enamel only in Tetric N-Bond (P > 0.05). In non-applied CPP-ACP subgroups, there were statistically significant differences among all subgroups. Tetric N-Bond had the highest and AdheSE One F had the lowest shear bond strength. Conclusion: CPP-ACP application reduces the shear bond strength of AdheSE and AdheSE One F to enamel but not Tetric N-Bond. PMID:25878683

  2. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations

    PubMed Central

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Objective: Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Materials and Methods: Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5–55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal–Wallis and Bonferroni–Dunn test. Results: The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni–Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). Conclusion: The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition. PMID:27095890

  3. Effect of endodontic chelating solutions on the bond strength of endodontic sealers.

    PubMed

    Tuncel, Behram; Nagas, Emre; Cehreli, Zafer; Uyanik, Ozgur; Vallittu, Pekka; Lassila, Lippo

    2015-01-01

    The purpose of this in vitro study was to evaluate the effect of various chelating solutions on the radicular push-out bond strength of calcium silicate-based and resin-based root canal sealers. Root canals of freshly-extracted single-rooted teeth (n = 80) were instrumented by using rotary instruments. The specimens were randomly divided into 4 groups according to the chelating solutions being tested: (1) 17% ethylenediaminetetraacetic acid (EDTA); (2) 9% etidronic acid; (3) 1% peracetic acid (PAA); and (4) distilled water (control). In each group, the roots were further assigned into 2 subgroups according to the sealer used: (1) an epoxy resin-based sealer (AH Plus) and (2) a calcium silicate-based sealer (iRoot SP). Four 1 mm-thick sections were obtained from the coronal aspect of each root (n = 40 slices/group). Push-out bond strength test was performed at a crosshead speed of 1 mm/min., and the bond strength data were analyzed statistically with two-way analysis of variance (ANOVA) with Bonferroni's post hoc test (p < 0.05). Failure modes were assessed quantitatively under a stereomicroscope. Irrespective of the irrigation regimens, iRoot SP exhibited significantly higher push-out bond strength values than AH Plus (p < 0.05). For both the sealers, the use of chelating solutions increased the bond strength, but to levels that were not significantly greater than their respective controls (p > 0.05). iRoot SP showed higher resistance to dislocation than AH Plus. Final irrigation with 17% EDTA, 9% Etidronic acid, and 1% PAA did not improve the bond strength of AH Plus and iRoot SP to radicular dentin.

  4. Surface Detail Reproduction and Dimensional Stability of Contemporary Irreversible Hydrocolloid Alternatives after Immediate and Delayed Pouring.

    PubMed

    Kusugal, Preethi; Chourasiya, Ritu Sunil; Ruttonji, Zarir; Astagi, Preeti; Nayak, Ajay Kumar; Patil, Abhishekha

    2018-01-01

    To overcome the poor dimensional stability of irreversible hydrocolloids, alternative materials were introduced. The dimensional changes of these alternatives after delayed pouring are not well studied and documented in the literature. The purpose of the study is to evaluate and compare the surface detail reproduction and dimensional stability of two irreversible hydrocolloid alternatives with an extended-pour irreversible hydrocolloid at different time intervals. All testing were performed according to the ANSI/ADA specification number 18 for surface detail reproduction and specification number 19 for dimensional change. The test materials used in this study were newer irreversible hydrocolloid alternatives such as AlgiNot FS, Algin-X Ultra FS, and Kromopan 100 which is an extended pour irreversible hydrocolloid as control. The surface detail reproduction was evaluated using stereomicroscope. The dimensional change after storage period of 1 h, 24 h, and 120 h was assessed and compared between the test materials and control. The data were analyzed using one-way ANOVA and post hoc Bonferroni test. Statistically significant results ( P < 0.001) were seen when mean scores of the tested materials were compared with respect to reproduction of 22 μm line from the metal block. Kromopan 100 showed statistically significant differences between different time intervals ( P < 0.001) and exhibited more dimensional change. Algin-X Ultra FS proved to be more accurate and dimensionally stable. Newer irreversible hydrocolloid alternative impression materials were more accurate in surface detail reproduction and exhibited minimal dimensional change after storage period of 1 h, 24 h, and 120 h than extended-pour irreversible hydrocolloid impression material.

  5. The effect of short fiber composite base on microleakage and load-bearing capacity of posterior restorations

    PubMed Central

    Garoushi, Sufyan K.; Hatem, Marwa; Lassila, Lippo V. J.; Vallittu, Pekka K.

    2015-01-01

    Abstract Objectives: To determine the marginal microleakage of Class II restorations made with different composite base materials and the static load-bearing capacity of direct composite onlay restorations. Methods: Class II cavities were prepared in 40 extracted molars. They were divided into five groups (n = 8/group) depending on composite base material used (everX Posterior, SDR, Tetric EvoFlow). After Class II restorations were completed, specimens were sectioned mid-sagitally. For each group, sectioned restorations were immersed in dye. Specimens were viewed under a stereo-microscope and the percentage of cavity leakage was calculated. Ten groups of onlay restorations were fabricated (n = 8/group); groups were made with composite base materials (everX Posterior, SDR, Tetric EvoFlow, Gradia Direct LoFlo) and covered by 1 mm layer of conventional (Tetric N-Ceram) or bulk fill (Tetric EvoCeram Bulk Fill) composites. Groups made only from conventional, bulk fill and short fiber composites were used as control. Specimens were statically loaded until fracture. Data were analyzed using ANOVA (p = 0.05). Results: Microleakage of restorations made of plain conventional composite or short fiber composite base material showed statistically (p < 0.05) lower values compared to other groups. ANOVA revealed that onlay restorations made from short fiber-reinforced composite (FRC) as base or plain restoration had statistically significant higher load-bearing capacity (1593 N) (p < 0.05) than other restorations. Conclusion: Restorations combining base of short FRC and surface layer of conventional composite displayed promising performance related to microleakage and load-bearing capacity. PMID:28642894

  6. Stereomicroscope Inspection of Polished Aluminum Collector 50684.0

    NASA Technical Reports Server (NTRS)

    Rodriquez, M. C.; Calaway, M. J.; Allton, J. H.

    2008-01-01

    The Genesis polished aluminum "kidney" collector was damaged during the hard landing of the capsule on September 8, 2004 in the Utah desert. The kidney was introduced into the Genesis (ISO class 4) cleanroom laboratory on November 4, 2004 and stored under nitrogen cover gas. The collector is currently fastened to a highly polished stainless steel plate for secure handling. Curatorial work at JSC has made successful subdivision and subsequent allocation of samples from the kidney.

  7. A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

    PubMed Central

    Shankarappa, Pushpa; Misra, Abhinav; Sawhney, Asheesh; Sridevi, Nandamuri; Singh, Anu

    2016-01-01

    Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects. PMID:27446636

  8. Effects of elevated temperatures on different restorative materials: An aid to forensic identification processes

    PubMed Central

    Pol, Chetan A.; Ghige, Suvarna K.; Gosavi, Suchitra R.; Hazarey, Vinay K.

    2015-01-01

    Background: Heat-induced alterations to dental and restorative materials can be of great interest to forensic dentistry. Knowing the specific optical behavior of dental materials can be of high importance as recognition of changes induced by high temperatures can lead to the determination of material which was used in a dental restoration, facilitating identification of burned human remains. Aim: To observe the effects of predetermined temperatures (200°C–400°C–600°C–800°C–1000°C) on unrestored teeth and different restorative materials macroscopically and then examine them under a stereomicroscope for the purpose of identification. Materials and Methods: The study was conducted on 375 extracted teeth which were divided into five groups of 75 teeth each as follows: group 1- unrestored teeth, group 2- teeth restored with all-ceramic crowns, Group 3- with class I silver amalgam filling, group 4- with class I composite restoration, and group 5- with class I glass ionomer cement restoration. Results: Unrestored and restored teeth display a series of specific macroscopic & stereomicroscopic structural changes for each range of temperature. Conclusion: Dental tissues and restorative materials undergo a series of changes which correlate well with the various temperatures to which they were exposed. These changes are a consequence of the nature of the materials and their physicochemical characteristics. PMID:26005305

  9. Effect of Anatomical Customization of the Fiber Post on the Bond Strength of a Self-Adhesive Resin Cement

    PubMed Central

    Rocha, Adricyla Teixeira; Vasconcelos, Ana Júlia de Carvalho; Nunes Carvalho, Ceci

    2017-01-01

    Aim The aim of the study was to evaluate, by means of the push-out test, the effect of the anatomical customization of the fiber post on the bond strength of a self-adhesive resin cement. Methods Twelve endodontically treated, human, upper central incisors were randomly divided into two groups (n = 6): control (glass fiber posts cemented with Relyx® U200) and customized (glass fiber posts anatomically customized with translucent composite resin cemented with Relyx U200). The roots were sectioned into three slices, cervical, middle, and apical, and photographed with a digital camera attached to a stereomicroscopic loupe. The images were analyzed by software, for evaluation of the cement line. The slices were subsequently submitted to the push-out test until the post had completely extruded, and the fracture mode was analyzed with a stereomicroscopic loupe. Results The results showed significant differences between the groups in the different root thirds in relation to the area occupied by air bubbles (p < 0.05). Bond strength, when all the thirds are considered, was 8.77 ± 4.89 MPa for the control group and 16.96 ± 4.85 MPa for the customized group. Conclusion The customized group showed greater bond resistance than the control group and a more uniform cement layer. PMID:28785281

  10. Comparison of Marginal and Internal Adaptation of Heat-Pressed and CAD/CAM Porcelain Laminate Veneers and a 2-Year Follow-Up.

    PubMed

    Yuce, Mert; Ulusoy, Mubin; Turk, Ayse Gozde

    2017-12-22

    To compare marginal and internal adaptations of porcelain laminate veneers fabricated with heat-pressed and CAD/CAM techniques, and to evaluate the clinical performances 2 years after cementation. Thirty heat-pressed and 31 CAD/CAM porcelain laminate veneers were fabricated for 12 patients. Silicone replicas of each veneer were obtained. Replicas were sectioned into 4 parts to measure adaptations of the veneers. A stereomicroscope was used to measure from 3 locations of replicas for marginal, and 9 locations for internal adaptations at 40x magnification. Clinical evaluations were done at baseline and 6, 12, 18, and 24 months after cementation according to the modified United States Public Health Service (USPHS) criteria. Independent samples t-test compared the adaptation values between heat-pressed and CAD/CAM groups. Paired t-test was used to evaluate marginal and internal adaptations of each group. Differences between the modified USPHS criteria ratings of heat-pressed and CAD/CAM groups were determined by the Mann-Whitney U test. Kaplan-Meier analysis was used to analyze the survival ratings of the veneers (p < 0.05). The mean marginal adaptation values of heat-pressed and CAD/CAM veneers were 295 and 314.98 μm, respectively, and there was no statistically significant difference (p = 0.541). Internal adaptation values of groups were not statistically different either (201.82 μm for heat pressed; 195.47 μm for CAD/CAM p = 0.734). When marginal and internal adaptation values were compared within groups, there were significant differences both for heat-pressed (p < 0.001) and CAD/CAM (p < 0.001). All veneers were rated 100% satisfactory during the 2-year period. Within the limitations of this study, fabrication method, whether CAD/CAM or heat-pressed, had no effect on the marginal and internal adaptation of porcelain laminate veneers. The results showed that both fabrication techniques performed well after 2 years of clinical performance. © 2017 by the American College of Prosthodontists.

  11. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate as a root end filling material: an ex vivo evaluation.

    PubMed

    Shetty, K Harish Kumar; Prathap, M S; Prithviraj, K J

    2013-01-01

    The aim of this study was to evaluate the sealing ability of white and gray mineral trioxide aggregate (MTA) mixed with distilled water and 0.12% chlorhexidine (CHX) gluconate when used as a root-end filling material using the dye-penetration technique. A total of 48 single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH Plus sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 8 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After application of nail polish, the teeth were exposed to India ink for 72 h and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. No statistically significant differences were observed in the sealing ability of gray and white MTA mixed with distilled water and 0.12% CHX. CHX appears to be a good alternative to replace distilled water, as a solution to be mixed with MTA.

  12. An evaluation of microleakage of various glass ionomer based restorative materials in deciduous and permanent teeth: An in vitro study

    PubMed Central

    Singla, Teena; Pandit, I.K.; Srivastava, Nikhil; Gugnani, Neeraj; Gupta, Monika

    2011-01-01

    Aim To evaluate the microleakage of recently available glass ionomer based restorative materials (GC Fuji IX GP, GC Fuji VII, and Dyract) and compare their microleakage with the previously existing glass ionomer restorative materials (GC Fuji II LC) in primary and permanent teeth. Method One hundred and fifty (75 + 75) non-carious deciduous and permanent teeth were restored with glass ionomer based restorative materials after making class I cavities. Samples were subjected to thermocycling after storing in distilled water for 24 h. Two coats of nail polish were applied 1 mm short of restorative margins and samples sectioned buccolingually after storing in methylene blue dye for 24 h. Microleakage was assessed using stereomicroscope. Result Significant differences (P < 0.05) were found when inter group comparisons were done. Except when GC Fuji VII (Group III) was compared with GC Fuji II LC (Group II) and Dyract (Group IV), non-significant differences (P > 0.05) were observed. It was found that there was no statistically significant difference when the means of microleakage of primary teeth were compared with those of permanent teeth. Conclusions GC Fuji IX GP showed maximum microleakage and GC Fuji VII showed least microleakage. PMID:23960526

  13. "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

    PubMed

    Priya, N Tulasi; Chandrasekhar, Veeramachaneni; Anita, S; Tummala, Muralidhar; Raj, T B Phanindhar; Badami, Vijetha; Kumar, Pradeep; Soujanya, E

    2014-12-01

    The purpose of this study was to compare the incidence of dentinal micro cracks after instrumentation with various types of NiTi files in rotary and reciprocating motion. One hundred human extracted mandibular central incisors were taken and divided into 10 groups (n=10 teeth per group). Group 1- No preparation, Group 2 - Hand instrumentation, Groups 3,4 - ProTaper files in rotary and reciprocating motion, Groups 5,6 - ProTaper Next files in rotary and reciprocating motion, Groups 7,8 - Oneshape files in rotary and reciprocating motion, Groups 9,10 - Reciproc files in rotary and reciprocating motion. Specimens were sectioned horizontally at 3,6 and 9 mm from the apex and dentinal micro cracks were observed under a stereomicroscope. There was a statistically significant difference between the groups (p<0.05). There were no significant differences in crack formation between the groups (Protaper Next - Rot, Protaper Next - Rec, Reciproc - Rec); (ProTaper - Rot, ProTaper - Rec, Oneshape - Rot), (Oneshape - Rot, Reciproc - Rot), (One shape Reciproc, Reciproc - Rec); (p >.05). Least cracks were seen in canals instrumented with Pro Taper Next files both in rotary and reciprocating motion. Full sequence rotary systems showed less cracks than single file systems and full sequence rotary systems showed less cracks in reciprocating motion than in rotary motion.

  14. Surface topography and bond strengths of feldspathic porcelain prepared using various sandblasting pressures.

    PubMed

    Moravej-Salehi, Elham; Moravej-Salehi, Elahe; Valian, Azam

    2016-11-01

    The purpose of this study was to determine the bond strength of composite resin to feldspathic porcelain and its surface topography after sandblasting at different pressures. In this in vitro study, 68 porcelain disks were fabricated and randomly divided into four groups of 17. The porcelain surface in group 1 was etched with hydrofluoric acid. Groups 2, 3, and 4 were sandblasted at 2, 3 and 4 bars pressure, respectively. Surface topography of seven samples in each of the four groups was examined by a scanning electron microscope (SEM). The remaining 40 samples received the same silane agent, bonding agent, and composite resin and they were then subjected to 5000 thermal cycles and evaluated for shear bond strength. Data were analyzed using one-way anova. The mode of failure was determined using stereomicroscope and SEM. The highest shear bond strength was seen in group 4. however, statistically significant differences were not seen between the groups (P = 0.780). The most common mode of failure was cohesive in porcelain. The SEM showed different patterns of hydrofluoric acid etching and sandblasting. Increasing the sandblasting pressure increased the surface roughness of feldspathic porcelain but no difference in bond strength occurred. © 2015 Wiley Publishing Asia Pty Ltd.

  15. Marginal microleakage of triage sealant under different moisture contamination.

    PubMed

    Peng, Yawen; Stark, Paul C; Rich, Alfred; Loo, Cheen Y

    2011-01-01

    Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.

  16. Evaluation of two imaging techniques: near-infrared transillumination and dental radiographs for the detection of early approximal enamel caries.

    PubMed

    Maia, A M A; Karlsson, L; Margulis, W; Gomes, A S L

    2011-10-01

    The aim of this paper was to evaluate a transillumination (TI) system using near-infrared (NIR) light and bitewing radiographs for the detection of early approximal enamel caries lesions. Mesiodistal sections of teeth (n = 14) were cut with various thicknesses from 1.5 mm to 4.75 mm. Both sides of each section were included, 17 approximal surfaces with natural enamel caries and 11 surfaces considered intact. The approximal surfaces were illuminated by NIR light and X-ray. Captured images were analysed by two calibrated specialists in radiology, and re-analysed after 6 months using stereomicroscope images as a gold standard. The interexaminer reliability (Kappa test statistic) for the NIR TI technique showed moderate agreement on first (0.55) and second (0.48) evaluation, and low agreement for bitewing radiographs on first (0.26) and second (0.32) evaluation. In terms of accuracy, the sensitivity for the NIR TI system was 0.88 and the specificity was 0.72. For the bitewing radiographs the sensitivity ranged from 0.35 to 0.53 and the specificity ranged from 0.50 to 0.72. In the same samples and conditions tested, NIR TI images showed reliability and the enamel caries surfaces were better identified than on dental radiographs.

  17. Evaluation of two imaging techniques: near-infrared transillumination and dental radiographs for the detection of early approximal enamel caries

    PubMed Central

    Maia, A M A; Karlsson, L; Margulis, W; Gomes, A S L

    2011-01-01

    Objectives The aim of this paper was to evaluate a transillumination (TI) system using near-infrared (NIR) light and bitewing radiographs for the detection of early approximal enamel caries lesions. Methods Mesiodistal sections of teeth (n = 14) were cut with various thicknesses from 1.5 mm to 4.75 mm. Both sides of each section were included, 17 approximal surfaces with natural enamel caries and 11 surfaces considered intact. The approximal surfaces were illuminated by NIR light and X-ray. Captured images were analysed by two calibrated specialists in radiology, and re-analysed after 6 months using stereomicroscope images as a gold standard. Results The interexaminer reliability (Kappa test statistic) for the NIR TI technique showed moderate agreement on first (0.55) and second (0.48) evaluation, and low agreement for bitewing radiographs on first (0.26) and second (0.32) evaluation. In terms of accuracy, the sensitivity for the NIR TI system was 0.88 and the specificity was 0.72. For the bitewing radiographs the sensitivity ranged from 0.35 to 0.53 and the specificity ranged from 0.50 to 0.72. Conclusion In the same samples and conditions tested, NIR TI images showed reliability and the enamel caries surfaces were better identified than on dental radiographs. PMID:21960400

  18. Single cells for forensic DNA analysis--from evidence material to test tube.

    PubMed

    Brück, Simon; Evers, Heidrun; Heidorn, Frank; Müller, Ute; Kilper, Roland; Verhoff, Marcel A

    2011-01-01

    The purpose of this project was to develop a method that, while providing morphological quality control, allows single cells to be obtained from the surfaces of various evidence materials and be made available for DNA analysis in cases where only small amounts of cell material are present or where only mixed traces are found. With the SteREO Lumar.V12 stereomicroscope and UV unit from Zeiss, it was possible to detect and assess single epithelial cells on the surfaces of various objects (e.g., glass, plastic, metal). A digitally operated micromanipulator developed by aura optik was used to lift a single cell from the surface of evidence material and to transfer it to a conventional PCR tube or to an AmpliGrid(®) from Advalytix. The actual lifting of the cells was performed with microglobes that acted as carriers. The microglobes were held with microtweezers and were transferred to the DNA analysis receptacles along with the adhering cells. In a next step, the PCR can be carried out in this receptacle without removing the microglobe. Our method allows a single cell to be isolated directly from evidence material and be made available for forensic DNA analysis. © 2010 American Academy of Forensic Sciences.

  19. Remineralization effects of two pediatric dentifrices and one regular dentifrice on artificial carious lesion in primary teeth: An in vitro study

    PubMed Central

    Advani, Shweta; Sogi, Suma; Hugar, Shivayogi; Indushekar, K. R.; Kiran, K.; Hallikerimath, Seema

    2014-01-01

    Aim: The aim of the following study is to know the efficacy of remineralization of two pediatric dentifrices and one regular dentifrice on artificial carious lesions in primary teeth. Materials and Methods: A total of 21 teeth coated with nail varnish leaving a window of 1 mm were subjected to demineralization for 72 h. These 21 teeth were then sectioned into two equal parts with a diamond disc. The 42 sections obtained were then evaluated under the stereomicroscope and the demineralization values were noted. The 42 sections were divided into three groups: Group 1: Kidodent, Group 2: Cheeriogel, Group 3: Colgate Total and subjected to remineralization respectively for 7 days. The specimens were again evaluated under the stereomicroscope for the remineralisation values. Results: All the three dentifrices showed remineralization with artificial carious lesions. Colgate Total showed higher remineralization rates compared with the other two pediatric dentifrices. Kidodent showed a slightly higher remineralisation rate compared with Cheeriogel which was not significant. Conclusion/Hypothesis: The pediatric dentifrices also showed remineralization with artificial carious lesions. Hence, we conclude that, this amount of remineralization was more or less, when compared to the regular dentifrice which showed higher remineralization rates, which could lead to adverse effects, like fluorosis if not used judiciously. On basis of which we hypothetize: Pediatric dentifrices have an appropriate fluoride content, as required by the children, and also does not minimize the cariostatic effects. PMID:25254193

  20. Slant Perception Under Stereomicroscopy.

    PubMed

    Horvath, Samantha; Macdonald, Kori; Galeotti, John; Klatzky, Roberta L

    2017-11-01

    Objective These studies used threshold and slant-matching tasks to assess and quantitatively measure human perception of 3-D planar images viewed through a stereomicroscope. The results are intended for use in developing augmented-reality surgical aids. Background Substantial research demonstrates that slant perception is performed with high accuracy from monocular and binocular cues, but less research concerns the effects of magnification. Viewing through a microscope affects the utility of monocular and stereo slant cues, but its impact is as yet unknown. Method Participants performed in a threshold slant-detection task and matched the slant of a tool to a surface. Different stimuli and monocular versus binocular viewing conditions were implemented to isolate stereo cues alone, stereo with perspective cues, accommodation cue only, and cues intrinsic to optical-coherence-tomography images. Results At magnification of 5x, slant thresholds with stimuli providing stereo cues approximated those reported for direct viewing, about 12°. Most participants (75%) who passed a stereoacuity pretest could match a tool to the slant of a surface viewed with stereo at 5x magnification, with mean compressive error of about 20% for optimized surfaces. Slant matching to optical coherence tomography images of the cornea viewed under the microscope was also demonstrated. Conclusion Despite the distortions and cue loss introduced by viewing under the stereomicroscope, most participants were able to detect and interact with slanted surfaces. Application The experiments demonstrated sensitivity to surface slant that supports the development of augmented-reality systems to aid microscope-aided surgery.

  1. Effect of aluminum chloride hemostatic agent on microleakage of class V composite resin restorations bonded with all-in-one adhesive

    PubMed Central

    Mohammadi, Narmin; Bahari, Mahmood; Pournaghi-Azar, Fatemeh; Mozafari, Aysan

    2012-01-01

    Objectives: Since hemostatic agents can induce changes on enamel and dentin surfaces and influence composite resin adhesion, the aim of the present study was to evaluate the effect of the aluminum chloride hemostatic agent on the gingival margin microleakage of class V (Cl V) composite resin restorations bonded with all-in-one adhesive. Study design: Cl V cavities were prepared on the buccal surfaces of 60 sound bovine permanent incisors. Gingival margins of the cavities were placed 1.5 mm apical to the cemento-enamel junction (CEJ). The teeth were randomly divided into two groups of 30. In group 1, the cavities were restored without the application of a hemostatic agent; in group 2, the cavities were restored after the application of the hemostatic agent. In both groups all-in-one adhesive and Z250 composite resin were used to restore the cavities with the incremental technique. After finishing and polishing, the samples underwent a thermocycling procedure, followed by immersion in 2% basic fuschin solution for 24 hours. The samples were sectioned and gingival microleakage was evaluated under a stereomicroscope. The non-parametric Mann-Whitney U test was used to compare microleakage between the two groups. Statistical significance was defined at P<0.05. Results: A statistically significant difference was observed in microleakage between the two groups (P<0.001). Conclusions: Contamination of Cl V composite resin restorations bonded with all-in-one adhesive with aluminum chloride hemostatic agent significantly increases restoration gingival margin microleakage. Key words:All-in-one adhesive resin, composite resin restoration, hemostatic agent, microleakage. PMID:22322497

  2. Surface Detail Reproduction and Dimensional Stability of Contemporary Irreversible Hydrocolloid Alternatives after Immediate and Delayed Pouring

    PubMed Central

    Kusugal, Preethi; Chourasiya, Ritu Sunil; Ruttonji, Zarir; Astagi, Preeti; Nayak, Ajay Kumar; Patil, Abhishekha

    2018-01-01

    Purpose: To overcome the poor dimensional stability of irreversible hydrocolloids, alternative materials were introduced. The dimensional changes of these alternatives after delayed pouring are not well studied and documented in the literature. The purpose of the study is to evaluate and compare the surface detail reproduction and dimensional stability of two irreversible hydrocolloid alternatives with an extended-pour irreversible hydrocolloid at different time intervals. Materials and Methods: All testing were performed according to the ANSI/ADA specification number 18 for surface detail reproduction and specification number 19 for dimensional change. The test materials used in this study were newer irreversible hydrocolloid alternatives such as AlgiNot FS, Algin-X Ultra FS, and Kromopan 100 which is an extended pour irreversible hydrocolloid as control. The surface detail reproduction was evaluated using stereomicroscope. The dimensional change after storage period of 1 h, 24 h, and 120 h was assessed and compared between the test materials and control. The data were analyzed using one-way ANOVA and post hoc Bonferroni test. Results: Statistically significant results (P < 0.001) were seen when mean scores of the tested materials were compared with respect to reproduction of 22 μm line from the metal block. Kromopan 100 showed statistically significant differences between different time intervals (P < 0.001) and exhibited more dimensional change. Algin-X Ultra FS proved to be more accurate and dimensionally stable. Conclusions: Newer irreversible hydrocolloid alternative impression materials were more accurate in surface detail reproduction and exhibited minimal dimensional change after storage period of 1 h, 24 h, and 120 h than extended-pour irreversible hydrocolloid impression material. PMID:29599578

  3. Flexural strength and failure modes of layered ceramic structures.

    PubMed

    Borba, Márcia; de Araújo, Maico D; de Lima, Erick; Yoshimura, Humberto N; Cesar, Paulo F; Griggs, Jason A; Della Bona, Alvaro

    2011-12-01

    To evaluate the effect of the specimen design on the flexural strength (σ(f)) and failure mode of ceramic structures, testing the hypothesis that the ceramic material under tension controls the mechanical performance of the structure. Three ceramics used as framework materials for fixed partial dentures (YZ--Vita In-Ceram YZ; IZ--Vita In-Ceram Zirconia; AL--Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs (n=10): monolithic, two layers (porcelain-framework) and three layers (TRI) (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. For bi-layered design, the specimens were tested in both conditions: with porcelain (PT) or framework ceramic (FT) layer under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy (SEM). Young's modulus (E) and Poisson's ratio (ν) were determined using ultrasonic pulse-echo method. Results were statistically analyzed by Kruskal-Wallis and Student-Newman-Keuls tests. Except for VM7 and VM9, significant differences were observed for E values among the materials. YZ showed the highest ν value followed by IZ and AL. YZ presented the highest σ(f). There was no statistical difference in the σ(f) value between IZ and IZ-FT and between AL and AL-FT. σ(f) values for YZ-PT, IZ-PT, IZ-TRI, AL-PT, AL-TRI were similar to the results obtained for VM7 and VM9. Two types of fracture mode were identified: total and partial failure. The mechanical performance of the specimens was determined by the material under tension during testing, confirming the study hypothesis. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. Counting pollen grains using readily available, free image processing and analysis software.

    PubMed

    Costa, Clayton M; Yang, Suann

    2009-10-01

    Although many methods exist for quantifying the number of pollen grains in a sample, there are few standard methods that are user-friendly, inexpensive and reliable. The present contribution describes a new method of counting pollen using readily available, free image processing and analysis software. Pollen was collected from anthers of two species, Carduus acanthoides and C. nutans (Asteraceae), then illuminated on slides and digitally photographed through a stereomicroscope. Using ImageJ (NIH), these digital images were processed to remove noise and sharpen individual pollen grains, then analysed to obtain a reliable total count of the number of grains present in the image. A macro was developed to analyse multiple images together. To assess the accuracy and consistency of pollen counting by ImageJ analysis, counts were compared with those made by the human eye. Image analysis produced pollen counts in 60 s or less per image, considerably faster than counting with the human eye (5-68 min). In addition, counts produced with the ImageJ procedure were similar to those obtained by eye. Because count parameters are adjustable, this image analysis protocol may be used for many other plant species. Thus, the method provides a quick, inexpensive and reliable solution to counting pollen from digital images, not only reducing the chance of error but also substantially lowering labour requirements.

  5. Complex investigation of body and clothing injuries during the identification of the assault instrument.

    PubMed

    Sitiene, R; Varnaite, J; Zakaras, A

    2004-12-02

    The value of complex analyses of body injuries and clothing has been proven by practice. The purpose of presented study is to discuss what additional information can be obtained during investigations of clothes in the area of injury. A case study, in which results of visual and stereomicroscopic morphological analysis of wounds, lesions of clothing and their comparison are presented. Examination of wounds revealed that some of them were made by blunt, others--by stabbing instrument. Lesions of clothes were made by secant instrument. Comparison of data enabled to determine characteristics of the instrument with greater precision--it was secant-stabbing tool. An experiment with suspected assault instrument--wheel wrench--under controlled conditions was performed. It was found that the head of this wheel wrench can be fixated when secant blow are performed, and it's sharp edge leaves secant-stabbing wounds. Our study revealed that precise knowledge of the assault circumstances enabled to select suitable conditions for experiment and this in turn enabled to identify the instrument of assault.

  6. Deformation and fracture of K3 rotary nickel-titanium endodontic instruments after clinical use.

    PubMed

    Shen, S M; Deng, M; Wang, P P; Chen, X M; Zheng, L W; Li, H L

    2016-11-01

    The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P < 0.003) except for 0.08 files (P > 0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  7. [Evaluation of preparation of curved root canals using hand-used ProTaper].

    PubMed

    Nie, Min; Zhao, Xin-Chen; Peng, Bin; Fan, Ming-Wen; Bian, Zhuan

    2009-05-01

    To evaluate the shaping ability of hand-used ProTaper on curved canals using Endodontic Cube. Fifty-four curved root canals in vitro were selected and divided into three groups according to the curved degree (alpha), group A: 0 degrees < or = alpha < 25 degrees , group B: 25 degrees < or = alpha < 40 degrees , group C: 40 degrees < or = alpha < 55 degrees . Endodontic Cube was assembled, and each sample was sectioned perpendicular to the axis of the tooth into four sections with Isomer-Buhler in low speed. Then the root canals were prepared with hand-used ProTaper. Before and after shaping, photograph of all the sections were taken under a stereomicroscope. Statistical analyses were performed. The dentin cutting quantity of the whole canal prepared with ProTaper in group B and C was larger than that of group A. The deviation distance of the whole canal prepared by ProTaper in group C was significantly larger than that in group A, and the deviation distance in middle portion larger than that in group B. The maintaining ability in the middle portion of group C by ProTaper was worse than that of group A and B. The curvature of root canal may increase the cutting quantity of the -dentin and reduce the ability of remaining original canal shape prepared by ProTaper.

  8. Intraorifice sealing ability of different materials in endodontically treated teeth: An in vitro study.

    PubMed

    Parekh, Bandish; Irani, Rukshin S; Sathe, Sucheta; Hegde, Vivek

    2014-05-01

    Microbial contamination of the pulp space is one of the major factors associated with endodontic failure. Thus, in addition to a three dimentional apical filling a coronal seal for root canal fillings has been recommended. The present study was conducted to evaluate and compare the intra-orifice sealing ability of three experimental materials after obturation of the root canal system. Fourty single rooted mandibular premolars were decoronated, cleaned, shaped and obturated. Gutta-percha was removed to the depth of 3.5 mm from the orifice with a heated plugger. Ten specimens each were sealed with Light Cure Glass Ionomer Cement (LCGIC), Flowable Composite (Tetric N-Flow), and Light Cure Glass Ionomer Cement with Flowable Composite in Sandwich Technique along with a positive control respectively and roots submerged in Rhodamine-B dye in vacuum for one week. Specimens were longitudinally sectioned and leakage measured using a 10X stereomicroscope and graded for depth of leakage. According to the results of the present study LC GIC + Tetric N Flow demonstrated significantly better seal (P < 0.01) than LC GIC. However there was no statistically significant difference in leakage (P > 0.01) between Tetric N-Flow and LCGIC+Tetric N-Flow groups. In the current study LCGIC+Tetric N-Flow was found to be superior over other experimental materials as intra-orifice barriers.

  9. Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets.

    PubMed

    Sohrabi, Aydin; Jafari, Sanaz; Kimyai, Soodabeh; Rikhtehgaran, Sahand

    2016-10-01

    Since there is no standard method for rebonding loose ceramic brackets, the aim of this study was to evaluate the possibility of using Er,Cr:YSGG laser to eliminate the remaining composite materials from the base of ceramic brackets and to compare the bond strength of rebonded brackets with the new ones. Sixty-two extracted human premolars were mounted in acrylic cylinders. Thirty-one ceramic brackets were bonded, and shear bond strength was tested using Hounsfield testing machine. The remnants of the bonding material were removed from the bases of brackets using Er,Cr:YSGG laser. These brackets were rebonded to 31 fresh teeth and again shear bond strength was measured. Pattern of debonding was assessed in both cases under a stereomicroscope and graded according to ARI index. Data were analyzed with independent t-test and Fisher's exact test. Mean shear bond strength of the bond and rebond groups was 12.29 ± 5.46 and 10.58 ± 5.16 MPa, respectively. There were no significant differences between the two groups (p = 0.21). Pattern of bond failure was not statistically different between the two groups. Er,Cr:YSGG laser was effective in removing the remnants of bonding material from the base of ceramic brackets without any interference with the ceramic base itself, demonstrating that it might be a suitable method for rebonding ceramic brackets.

  10. The effect of immediate dentin sealing and optical powder removal method on the fracture resistance of CAD/CAM-fabricated endocrowns.

    PubMed

    El-Damanhoury, Hatem M; Gaintantzopoulou, Marianna

    2016-01-01

    To evaluate the effect of immediate dentin sealing and optical powder removal method on the fracture resistance of CAD/CAM-fabricated ceramic endocrowns. Seventy-eight extracted premolars were endodontically treated. Standardized endocrown preparations were done in 60 teeth. Teeth were divided equally (n = 10) depending on the treatment of dentin (delayed sealing [DS] or immediate sealing [IS]), and the methods of optical powder removal (air-water spray washing [AW]; microabrasion [MA]; or aqueous suspension of pumice [PB], followed by air-water spray washing). After cementation, specimens were thermocycled (5,000 cycles, 5°C/50°C) and stored in distilled water for 1 week. Specimens were loaded in compression using a universal testing machine until failure. Failure load was recorded, and modes of failure were examined under a stereomicroscope. Micromorphological evaluation of different dentin treatments was done under SEM (n = 3). Results were analyzed using two-way ANOVA and Bonferroni post hoc multiple comparison tests (α = 0.05). Fracture resistance of all IS groups was significantly lower than DS groups, except for AW. There was no statistically significant difference between powder removal methods. Immediate dentin sealing does not improve the fracture resistance of endocrown restorations. Air-water spray washing is adequate to remove the optical powder after optical scanning impression taking.

  11. Effect of Two Traditional Polyacrylic Acid Conditioners and 2% Chlorhexidine Digluconate on Cavosurface Microleakage of Glass Ionomer Restorations.

    PubMed

    Lugassy, Diva; Segal, Pnina; Blumer, Sigalit; Eger, Michal; Shely, Asaf; Matalon, Shlomo

    2018-05-11

    A lack of appropriate adhesiveness is one of the biggest problems in restorative dentistry today and the main cause of microleakage. This is especially true in pediatric dentistry where moisture control is more difficult to achieve. Glass ionomer restorative materials increase adhesion and decrease microleakage given their chemical adhesion to the remaining tooth substance. Pretreatment improves the adhesion quality. The aim of this study was to assess the microleakage of Glass ionomer restorative materials following application of 20% polyacrylic acid, 10% polyacrylic acid or 2% chlorhexidine digluconate in Class V cavities. Two Class V preparations were prepared on the buccal and lingual surfaces of 24 extracted human molars. The gingival wall was set below or above the CEJ. The teeth were divided into 2 groups. Group 1 was treated with 20% polyacrylic acid or 10% polyacrylic acid. Group 2 was treated with 10% polyacrylic acid or 2% chlorhexidine digluconate. Microleakage was evaluated using a light-reflecting stereomicroscope and stain penetration test. Two percent chlorhexidine digluconate was as efficient as the other conditioners. No statistically significant differences were found among the three types of conditioners. Dye penetration was significantly greater into dentin than into enamel among all three conditioners in both groups (P<0.001). Two percent chlorhexidine digluconate, with its known added advantages, can be used as a pretreatment conditioner in GI restorations.

  12. An in vitro assessment of type, position and incidence of isthmus in human permanent molars

    PubMed Central

    de LIMA, Fernando José Camello; MONTAGNER, Francisco; JACINTO, Rogério Castilho; AMBROSANO, Glaucia Maria Bovi; GOMES, Brenda Paula Figueiredo de Almeida

    2014-01-01

    Root canal anatomical complexities, such as isthmus, may limit the action of the endodontic instruments, irrigant solutions and intracanal medications, leading to endodontic treatment failure. Objectives This in vitro study assessed the type, position and incidence of isthmus in human permanent molars. Material and Methods One hundred and twenty eight upper and lower first and second permanent molars were analyzed. The roots were embedded in transparent resin, and then split at different distances from the apex (1.0-2.5-4.0-5.5-7.0 mm). Following the sample examination in stereomicroscope, the data were submitted to chi-square statistical test at a 5% significance level. Results The highest isthmus incidence was at 7.0 mm from the root apex in all samples, except the distal root of lower molars (at 5.5 mm). In upper and lower molars, type V (complete isthmus with a continuous opening between the two main root canals) was the most common classification of isthmus (28.8%). In the mesial root of first and second mandibular molars, type IV had the highest incidence (36% and 23.9%, respectively). Conclusion It was concluded that isthmus was widely found in flat roots, with a low percentage in areas close to the apex. In upper and lower molars, these structures were most frequently found at 7 mm from the apex. PMID:25141198

  13. Marginal adaptation of four inlay casting waxes on stone, titanium, and zirconia dies.

    PubMed

    Michalakis, Konstantinos X; Kapsampeli, Vassiliki; Kitsou, Aikaterini; Kirmanidou, Yvone; Fotiou, Anna; Pissiotis, Argirios L; Calvani, Pasquale Lino; Hirayama, Hiroshi; Kudara, Yukio

    2014-07-01

    Different inlay casting waxes do not produce copings with satisfactory marginal accuracy when used on different die materials. The purpose of this study was to evaluate the marginal accuracy of 4 inlay casting waxes on stone dies and titanium and zirconia abutments and to correlate the findings with the degree of wetting between the die specimens and the inlay casting waxes. The inlay casting waxes tested were Starwax (Dentaurum), Unterziehwachs (Bredent), SU Esthetic wax (Schuler), and Sculpturing wax (Renfert). The marginal opening of the waxes was measured with a stereomicroscope on high-strength stone dies and on titanium and zirconia abutments. Photographic images were obtained, and the mean marginal opening for each specimen was calculated. A total of 1440 measurements were made. Wetting between die materials and waxes was determined after fabricating stone, titanium, and zirconia rectangular specimens. A calibrated pipette was used to place a drop of molten wax onto each specimen. The contact angle was calculated with software after an image of each specimen had been made with a digital camera. Collected data were subjected to a 2-way analysis of variance (α=.05). Any association between marginal accuracy and wetting of different materials was found by using the Pearson correlation. The wax factor had a statistically significant effect both on the marginal discrepancy (F=158.31, P<.001) and contact angle values (F=68.09, P<.001). A statistically significant effect of the die material factor both on the marginal adaptation (F=503.47, P<.001) and contact angle values (F=585.02, P<.001) was detected. A significant correlation between the marginal accuracy and the contact angle values (Pearson=0.881, P=.01) was also found. Stone dies provided wax copings with the best marginal integrity, followed by titanium and zirconia abutments. Unterziehwachs (Bredent), wax produced the best marginal adaptation on different die materials. A significant correlation was found between the marginal accuracy and the contact angle values. As the contact angle value became smaller, the marginal accuracy improved. All combinations of waxes and stone and titanium dies presented a high wettability. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Composite Replacement of Amalgam Restoration Versus Freshly Cut Dentin: An In Vitro Microleakage Comparison.

    PubMed

    Redwan, H; Bardwell, D N; Ali, A; Finkelman, M; Khayat, S; Weber, H-P

    2016-01-01

    The aim of this study was to evaluate the microleakage of the composite restorations when bonded to tooth structure previously restored with amalgam material compared with that of freshly cut dentin. Thirty intact, extracted intact human molars were mounted in autopolymerizing acrylic resin. Class II box preparations were prepared on the occluso-proximal surfaces of each tooth (4-mm bucco-lingual width and 2-mm mesio-distal depth) with the gingival cavosurface margin 1 mm above the CEJ. Each cavity was then restored using high copper amalgam restoration (Disperalloy, Dentsply) and then thermocycled for 10,000 thermal cycles. Twenty-five of the amalgam restorations were then carefully removed and replaced with Filtek Supreme Ultra Universal (3M ESPE); the remaining five were used for scanning electron microscopy and energy dispersive x-ray spectroscopy analysis. A preparation of the same dimensions was performed on the opposite surface of the tooth and restored with composite resin and thermocycled for 5000 thermal cycles. Twenty samples were randomly selected for dye penetration testing using silver nitrate staining to detect the microleakage. The specimens were analyzed with a stereomicroscope at a magnification of 20×. All of the measurements were done in micrometers; two readings were taken for each cavity at the occlusal and proximal margins. Two measurements were taken using a 0-3 scale and the percentage measurements. Corrosion products were not detected in either group (fresh cut dentin and teeth previously restored with amalgam). No statistically significant difference was found between the microleakage of the two groups using a 0-3 scale at the occlusal margins (McNemar test, p=0.727) or proximal margins (Wilcoxon signed-rank test, p=0.174). No significance difference was found between the two groups using the percentage measurements and a Wilcoxon signed-rank test at either the occlusal (p=0.675) or proximal (p=0.513) margins. However, marginal microleakage was statistically significant between the proximal and occlusal margins (p<0.001). Within the limitations of this in vitro study, no significant difference was found between the microleakage of nondiscolored dentin in teeth that were previously restored with amalgam compared with freshly cut dentin. However, marginal microleakage in the proximal surface was higher than that in the occlusal surface.

  15. Micro-computed tomography of false starts produced on bone by different hand-saws.

    PubMed

    Pelletti, Guido; Viel, Guido; Fais, Paolo; Viero, Alessia; Visentin, Sindi; Miotto, Diego; Montisci, Massimo; Cecchetto, Giovanni; Giraudo, Chiara

    2017-05-01

    The analysis of macro- and microscopic characteristics of saw marks on bones can provide useful information about the class of the tool utilized to produce the injury. The aim of the present study was to test micro-computed tomography (micro-CT) for the analysis of false starts experimentally produced on 32 human bone sections using 4 different hand-saws in order to verify the potential utility of micro-CT for distinguishing false starts produced by different saws and to correlate the morphology of the tool with that of the bone mark. Each sample was analysed through stereomicroscopy and micro-CT. Stereomicroscopic analysis allowed the identification of the false starts and the detection of the number of tool marks left by each saw. Micro-CT scans, through the integration of 3D renders and multiplanar reconstructions (MPR), allowed the identification of the shape of each false start correlating it to the injuring tool. Our results suggest that micro-CT could be a useful technique for assessing false starts produced by different classes of saws, providing accurate morphological profiles of the bone marks with all the advantages of high resolution 3D imaging (e.g., high accuracy, non-destructive analysis, preservation and documentation of evidence). However, further studies are necessary to integrate qualitative data with quantitative metrical analysis in order to further characterize the false start and the related injuring tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Copper ion as a new leakage tracer.

    PubMed

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  17. Effect of the size of the apical enlargement with rotary instruments, single-cone filling, post space preparation with drills, fiber post removal, and root canal filling removal on apical crack initiation and propagation.

    PubMed

    Çapar, İsmail Davut; Uysal, Banu; Ok, Evren; Arslan, Hakan

    2015-02-01

    The purpose of this study was to investigate the incidence of apical crack initiation and propagation in root dentin after several endodontic procedures. Sixty intact mandibular premolars were sectioned perpendicular to the long axis at 1 mm from the apex, and the apical surface was polished. Thirty teeth were left unprepared and served as a control, and the remaining 30 teeth were instrumented with ProTaper Universal instruments (Dentsply Maillefer, Ballaigues, Switzerland) up to size F5. The root canals were filled with the single-cone technique. Gutta-percha was removed with drills of the Rebilda post system (VOCO, Cuxhaven, Germany). Glass fiber-reinforced composite fiber posts were cemented using a dual-cure resin cement. The fiber posts were removed with a drill of the post system. Retreatment was completed after the removal of the gutta-percha. Crack initiation and propagation in the apical surfaces of the samples were examined with a stereomicroscope after each procedure. The absence/presence of cracks was recorded. Logistic regression was performed to analyze statistically the incidence of crack initiation and propagation with each procedure. The initiation of the first crack and crack propagation was associated with F2 and F4 instruments, respectively. The logistic regression analysis revealed that instrumentation and F2 instrument significantly affected apical crack initiation (P < .001). Post space preparation had a significant effect on crack propagation (P = .0004). The other procedures had no significant effects on crack initiation and propagation (P > .05). Rotary nickel-titanium instrumentation had a significant effect on apical crack initiation, and post space preparation with drills had a significant impact on crack propagation. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Effect of Intra-Orifice Depth on Sealing Ability of Four Materials in the Orifices of Root-Filled Teeth: An Ex-Vivo Study

    PubMed Central

    Ghulman, Motaz Ahmad; Gomaa, Madiha

    2012-01-01

    Aim. To investigate the effect of orifice cavity depth on the sealing ability of Fusio, Fuji II, Fuji IX, and MTA“G”. Materials and Methods. Ninety-two canals in extracted mandibular premolars were prepared, obturated, and randomly grouped into 4 groups. Each group was subgrouped for a 2 mm and 3 mm orifice cavity depth (n = 10). The remaining roots were divided to serve as positive and negative controls (n = 6). Cavities of the 4 experimental groups were filled with the respective materials and subjected to methylene blue dye leakage. Linear leakage was measured in mm using a stereomicroscope. Statistical Analysis. Kruskall-Wallis test was used at P < 0.05, and t-test was done to compare 2 mm and 3 mm. Results. All tested materials leaked to various degrees. Significantly higher leakage score was found for Fuji IX, Fusio, Fuji II, and MTA “G” in a descending order, when the materials were placed at 3 mm depths. A significant difference was found in the leakage score between the 2 mm and 3 mm depths in all tested materials with the 3 mm depth showing a greater leakage score in all tested materials. Exception was in MTA “G” at 2 mm and 3 mm depths (0.551 mm ± 0.004 mm and 0.308 mm ± 0.08 mm, resp.). Conclusion. The null hypothesis should be partially rejected. Fusio and MTA “G” were affected by orifice cavity depth with regard to their sealing ability. MTA “G” had the least leakage when placed at 2 or 3 mm depths, and Fusio is the next when placed at 2 mm depth. Two millimeters orifice cavity depth is suitable for most adhesive orifice barrier materials. PMID:22675356

  19. Assessment of Bracket Surface Morphology and Dimensional Change

    PubMed Central

    Radhakrishnan, Pillai Devu; Sapna Varma, N. K.; Ajith, V. V.

    2017-01-01

    Objective: The objective of this study was to compare the surface morphology and dimensional stability of the bracket slot at the onset of treatment and after 12 months of intraoral exposure. The study also compared the amount of calcium at the bracket base which indicates enamel loss among the three orthodontic brackets following debonding after 12 months of intraoral exposure. Materials and Methods: The sample consisted of 60 (0.022” MBT) canine brackets. They were divided into three groups: self-ligating, ceramic bracket with metal slot, and stainless steel (SS) brackets. The slot dimensions, micromorphologic characteristics of as-received and retrieved brackets were measured with a stereomicroscope and scanning electron microscope (SEM), respectively. The amount of calcium at the bracket base which indicates enamel damage was quantified using energy-dispersive X-ray spectrometry (EDX). Results: The results showed statistically significant alterations (P < 0.05) in the right vertical dimension, internal tie wing width (cervical), right and left depth of the slot (Kruskal–Wallis test). Multiple comparison using Mann–Whitney test showed that ceramic brackets underwent (P < 0.05) minimal alterations in the right vertical dimension, internal tie wing width (cervical), right and left depth of the slot (0.01 mm, −0.003 mm, 0.006 mm, −0.002 mm, respectively) when compared with the changes seen in SS and self-ligating brackets. SEM analysis revealed an increase in the surface roughness of ceramic with metal slot brackets and self-ligating bracket showed the least irregularity. The presence of calcium was noted on all evaluated brackets under EDX, but ceramic with metal slot brackets showed a significantly greater amount of enamel loss (P = 0.001). Conclusion: Ceramic brackets were found to be dimensionally stable when compared to SS and self-ligating. Self-ligating bracket showed minimal surface irregularity. Ceramic with metal slot brackets showed a greater amount of enamel loss following debonding. PMID:28566855

  20. Effect of rotary instrumentation on composite bond strength with simulated pulpal pressure.

    PubMed

    Gupta, Ruchi; Tewari, Sanjay

    2006-01-01

    This study evaluated the effect of cutting teeth with different types of burs at various speeds on shear bond strength using Prime and Bond NT (Dentsply/DeTrey). A simulated pulpal pressure of 25-mmHg, equivalent to 34 cmH2O, was created in a false pulpal chamber filled with distilled water and maintained for seven days. The human teeth were divided into six groups of 10 teeth each: fine grit straight fissure diamond bur in air rotor (DA), fine grit straight fissure diamond bur in micromotor (DM), crosscut fissure carbide bur in air rotor (CCA), crosscut fissure carbide bur in micromotor (CCM), plain fissure carbide bur in micromotor (CM) and #600-grit silicon carbide paper (SiC). The tooth surfaces in these groups were cut under copious air-water spray and treated with Prime and Bond NT after etching with 38% phosphoric acid. Composite restorations were then prepared with TPH spectrum (Dentsply/ DeTrey). After soaking in water at 37 degrees C for 24 hours, the specimens were loaded at a 45 degrees angle to their longitudinal axes by using a Z 010 Universal Testing Machine (Zwick), and shear bond strengths were determined at a crosshead speed of 2 mm/minute. All of the specimens were then observed under Stereomicroscope at 10x. Statistical analysis was made using one-way and two-way ANOVA and t-test (p < 0.05). The bond strengths achieved with a fine grit straight fissure diamond bur, a crosscut fissure carbide bur in air rotor and a crosscut fissure carbide bur in micromotor, were significantly higher than a fine grit straight fissure diamond bur, a plain fissure carbide bur and #600-grit silicon carbide abrasive paper in the micromotor. Therefore, selecting an appropriate bur and its speed may improve bonding for adhesive systems, although crosscut fissure carbide burs produced high bond strengths at either speed used.

  1. A Comparative Evaluation of the Influence of Command Set Methods on Microleakage of Glass Ionomer Cement: An In Vitro Study.

    PubMed

    Punnathara, Sairaj; Krishnakumar, Ramalingam; Govindarajan, Mohan; Kanaran, Momeka; Philip, Sunil Thomas; Nair, Aswin Saseendran; Peter, Joby

    2017-06-01

    A major challenge when using glass ionomer cement in clinical situation particularly in paediatric dentistry is to overcome the problem of microleakage. Fast or command setting of Type IX glass ionomer cement using external energy source enhances the setting reaction and results in improved initial physical and mechanical properties. To compare and evaluate the influence of ultrasonic activation, halogen light irradiation and combined effect of both on microleakage of enamel adjacent to Type IX glass ionomer restorations. For forty premolar teeth, standard Class V cavities prepared were restored with GC Gold Label Type IX glass ionomer cement in vitro. The specimens were randomly divided into four groups: 1) Control group; 2) halogen group; 3) ultrasonic group; 4) ultrasonic with halogen group. The teeth were kept in distilled water for 24 hours. Teeth were exposed to 1500 thermocycles at temperature of 12°C ±2 and 60°C ±2 with alternate immersion in hot and cold water for one minute. First teeth were immersed in dye solution for four hours and then in developing solution for four hours. The samples were sectioned buccolingually through centre of the restorations and degree of dye penetration was assessed under stereomicroscope and scored. One-Way ANOVA model was constructed followed by post-hoc Tukey's test for multiple pair wise comparison of mean values. Statistically significant differences were found in microleakage among the four groups (p<0.001) with respect to dye penetration. Halogen group showed least microleakage followed by control but differences between them were statistically not significant (p>0.05). Similarly the differences between Ultrasonic plus halogen group and ultrasonic group were not significant (p>0.05). The differences between ultrasonic and halogen group were statistically significant (p<0.05). Halogen light decreases the microleakage of enamel adjacent to GC Type IX glass ionomer restorations, when used to accelerate the setting reaction of glass ionomers and can be used as command set method in paediatric dentistry.

  2. Non-Invasive Periodontal Probing Through Fourier-Domain Optical Coherence Tomography.

    PubMed

    Mota, Cláudia C B O; Fernandes, Luana O; Cimões, Renata; Gomes, Anderson S L

    2015-09-01

    Periodontitis is a multifactorial and infectious disease that may result in significant debilitation. The aim of this study is to exploit two optical coherence tomography (OCT) systems operating in the Fourier domain at different wavelengths, 930 and 1,325 nm, for structural analysis of periodontal tissue in porcine jaws. Five fresh porcine jaws were sectioned and stored in formalin before OCT analysis. Two- and three-dimensional OCT images of the tooth/gingiva interface were performed, and measurements of the gingival structures were obtained. The 930-nm OCT system operates in the spectral domain, whereas the 1,325-nm system is a swept-source model. Stereomicroscope images, the gold standard, were used for direct comparison. Through image analysis, it is possible to identify the free gingiva and the attached gingiva, the calculus deposition over tooth surfaces, and the subgingival calculus that enables the enlargement of the gingival sulcus. In addition, the gingival thickness and the gingival sulcus depth can be non-invasively measured, varying from 0.8 to 4 mm. Regarding the ability of the two OCT systems to visualize periodontal structures, the system operating at 1,325 nm shows a better performance, owing to a longer central wavelength that allows deeper tissue penetration. The results with the system at 930 nm can also be used, but some features could not be observed due to its lower penetration depth in the tissue.

  3. An in vitro comparison of casein phosphopeptide-amorphous calcium phosphate paste, casein phosphopeptide-amorphous calcium phosphate paste with fluoride and casein phosphopeptide-amorphous calcium phosphate varnish on the inhibition of demineralization and promotion of remineralization of enamel.

    PubMed

    Thakkar, Prachi Jayesh; Badakar, Chandrashekhar M; Hugar, Shivayogi M; Hallikerimath, Seema; Patel, Punit M; Shah, Parin

    2017-01-01

    This study aims to determine and compare the extent of inhibition of demineralization and promotion of remineralization of permanent molar enamel with and without application of three remineralizing agents. Forty extracted permanent molars were randomly divided into two groups 1 and 2, longitudinally sectioned into four and divided into subgroups A, B, C, and D. The sections were coated with nail varnish leaving a window of 3 mm × 3 mm. All sections of Group 1 were treated with their respective subgroup-specific agent: Casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) paste for subgroup A, CPP-amorphous calcium phosphate fluoride (ACPF) paste for subgroup B, CPP-ACPF varnish for subgroup C and subgroup D served as a control. The sections were then subjected to demineralization for 12 days following which lesional depth was measured under the stereomicroscope. All the sections of Group 2 were subjected to demineralization for 12 days, examined for lesional depth, then treated with their respective subgroup specific agents and immersed in artificial saliva for 7 days. The sections were then examined again under the stereomicroscope to measure the lesional depth. CPP-ACPF varnish caused significant inhibition of demineralization. All three agents showed significant remineralization of previously demineralized lesions. However, CPP-ACPF varnish showed the greatest remineralization, followed by CPP-ACPF paste and then CPP-ACP paste. This study shows that CPP-ACPF varnish is effective in preventing demineralization as well as promoting remineralization of enamel. Thus, it can be used as an effective preventive measure for pediatric patients where compliance with the use of tooth mousse may be questionable.

  4. [Comparison of effectiveness and safety between Twisted File technique and ProTaper Universal rotary full sequence based on micro-computed tomography].

    PubMed

    Chen, Xiao-bo; Chen, Chen; Liang, Yu-hong

    2016-02-18

    To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT). Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25 × magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Three-dimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared. The shorter preparation time [(0.53 ± 0.14) min] was observed in TF group, while the preparation time of PU group was (2.06 ± 0.39) min (P<0.05). In mid-root level, TF group shaping resulted in less canal center transportation than PU group [(0.070 ± 0.056) mm vs. (0.097 ± 0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25 × magnification. Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.

  5. Analysis of tooth marks in a homicide case. Observations by means of visual description, stereo-photography, scanning electron microscopy and stereometric graphic plotting.

    PubMed

    Bang, G

    1976-01-01

    In 1957 a woman was murdered in Oslo. Her left breast exhibited tooth marks. A man was arrested and sentenced to life imprisonment partly because of the dental evidence. He never admitted guilt and filed a petition for retrial. The present author was appointed as new dental expert. The material consisted of the fixed breast, models of the bite mark and models of the teeth of the convict, and several photographs. By means of visual examination, a magnifying glass, a lens stereoscope and a stereomicroscope characteristic details were noted. Stereoscopic picture pairs were taken, the material was studied by means of scanning electron microscopy and a stereometricgraphic plotting method permitting the outline of the tooth mark or the biting edge of a tooth to be registered in great detail in all three dimensions in the form of a contour map. This method has not previously been applied in the analysis of tooth marks in human skin. These examinations revealed no discrepancies but showed many corresponding characteristic features between the tooth marks and the teeth of the convict, resulting in the conclusion that it is highly probable that the tooth marks in the breast were made by the teeth of the convict.

  6. Diagnostic accuracy of the light microscope method to detect the eggs of Cardicola spp. in the gill filaments of the bluefin tuna.

    PubMed

    Palacios-Abella, José F; Rodríguez-Llanos, Javier; Víllora-Montero, María; Mele, Salvatore; Raga, Juan A; Montero, Francisco E

    2017-11-30

    Trematode blood flukes of the genus Cardicola are potentially lethal in bluefin tuna cultures. The present study proposed a new method to detect aporocotylid eggs in tuna gills. Aporocotylid eggs were detected by analysing a pair of gill filaments of five transversal areas of the eight holobranches of one hundred Atlantic bluefin tuna and observed with glycerol and a stereomicroscope with an oblique brightfield. Data were gathered according to holobranches, transversal areas and their combination. Eggs were uniformly distributed among the holobranches, but they had the highest prevalence in the second and fifth transversal areas, which is controversial with respect to previous studies of egg distribution. An abbreviated method called the T-two test, which had the highest sensitivity (96.8%), is proposed for the detection of Cardicola spp. infections instead of the analysis all the holobranches. The T-two test limits the time and cost of the egg parasite screening analysis. The analyses of ten samples could be sufficient to detect the presence of parasites in farmed bluefin tuna; fish from the wild are expected to be less infected and more samples (45) would therefore be necessary. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Changes in urinary stone composition in the Tunisian population: a retrospective study of 1,301 cases.

    PubMed

    Alaya, Akram; Nouri, Abdellatif; Belgith, Mohsen; Saad, Hammadi; Jouini, Riadh; Najjar, Mohamed Fadhel

    2012-05-01

    Studies that evaluate the effect of age on stone composition are scarce. The aim of this study was to highlight the changes in epidemiological characteristics (stone composition and location) of urolithiasis according to patients' age. We studied 1,301 urolithiasis patients with age ranging from 6 months to 92 yr (781 males and 520 females). Stone analysis was performed using a stereomicroscope and infrared spectroscopy to determine the morphological type and molecular composition of each stone. The annual average incidence of new stone formation was 31.7 per 100,000 persons. In 71.8% of cases, calculi were located in the upper urinary tract. Compared to other age groups, children and old men were more affected by bladder stones. Calcium oxalate monohydrate was the most frequent stone component, even though its frequency decreased with age (59.5% in young adults and 43.7% in the elderly, P<0.05) in favor of an increase in uric acid stones (11.5% in young adults and 36.4% in the elderly, P<0.05). Struvite stones were rare (3.8%) and more frequent in children than in adults. The analysis of these data showed that urinary stones in Tunisian patients are tending to evolve in the same direction as the stones in patients from industrialized countries.

  8. [Changes in kidney stones type according to sex and age in Tunisian patients].

    PubMed

    Alaya, A; Nouri, A; Belgith, M; Saad, H; Hell, I; Hellara, W; Jouini, R; Najjar, M F

    2012-03-01

    Studies that evaluate the effect of age and gender on the stone composition are scarce. The aim of this study is to highlight the modification of epidemiological characteristics of this pathology according to patients' sex and age. We studied 1269 urolithiasic patients ranging from 6 months to 92 years old and known as having urinary stones (752 males and 517 females). Stone analysis was performed respectively using a stereomicroscope and infrared spectroscopy to determine, respectively, the morphological type and molecular composition of each. The annual average incidence of new stone formation was 30.25 per 100,000 inhabitants. In 1041 patients (81%), calculi were located in the upper urinary tract. Children and old man were more affected by bladder stone. Calcium oxalate monohydrate remains the most frequent stone component even if its frequency fell according to age (63.2% in teenagers and 40.6% in elderly [p<0.05]) in favour of the increase of uric acid stones (3,5% in teenagers and 41.5% in elderly [p<0.05]). Struvite stones were rare (3.5%) and more frequent in children. The analysis of these data shows that urinary stones in Tunisia are tending to evolve in the same direction as in industrialized countries. Copyright © 2011 AEU. Published by Elsevier Espana. All rights reserved.

  9. Microgravity

    NASA Image and Video Library

    1991-04-03

    The USML-1 Glovebox (GBX) is a multi-user facility supporting 16 experiments in fluid dynamics, combustion sciences, crystal growth, and technology demonstration. The GBX has an enclosed working space which minimizes the contamination risks to both Spacelab and experiment samples. The GBX supports four charge-coupled device (CCD) cameras (two of which may be operated simultaneously) with three black-and-white and three color camera CCD heads available. The GBX also has a backlight panel, a 35 mm camera, and a stereomicroscope that offers high-magnification viewing of experiment samples. Video data can also be downlinked in real-time. The GBX also provides electrical power for experiment hardware, a time-temperature display, and cleaning supplies.

  10. Microgravity

    NASA Image and Video Library

    1995-08-29

    The USML-1 Glovebox (GBX) is a multi-user facility supporting 16 experiments in fluid dynamics, combustion sciences, crystal growth, and technology demonstration. The GBX has an enclosed working space which minimizes the contamination risks to both Spacelab and experiment samples. The GBX supports four charge-coupled device (CCD) cameras (two of which may be operated simultaneously) with three black-and-white and three color camera CCD heads available. The GBX also has a backlight panel, a 35 mm camera, and a stereomicroscope that offers high-magnification viewing of experiment samples. Video data can also be downlinked in real-time. The GBX also provides electrical power for experiment hardware, a time-temperature display, and cleaning supplies.

  11. Macroscopic and stereomicroscopic comparison of hacking trauma of bones before and after carbonization.

    PubMed

    Alunni, Véronique; Nogueira, Luísa; Quatrehomme, Gérald

    2018-03-01

    This experimental study examined lesions produced by a hatchet on pig femurs before and after carbonization. A total of 30 lesions were produced and analyzed using stereomicroscopy and then reexamined after carbonization. Not only was the sharp-blunt mechanism of the hacking trauma (V-shape, regularity of one edge, irregularity of the other edge, upraising, lateral pushing back, fossae dug laterally to the edge) still recognizable after carbonization; in some instances, the carbonization actually enhanced the features observed. Carbonization also did not significantly alter the measurements of the lesions. Carbonization tends to alter the structure of the bone especially in areas weakened by the blunt trauma.

  12. Comparison of retreatment ability of full-sequence reciprocating instrumentation and 360° rotary instrumentation.

    PubMed

    Capar, Ismail Davut; Gok, Tuba; Orhan, Ezgi

    2015-12-01

    The purpose of the present study was to investigate the amount of root canal filling material after root canal filling removal with 360° rotary instrumentation or reciprocating motion with the same file sequence. Root canals of the 36 mandibular premolars were shaped with ProTaper Universal instruments up to size F2 and filled with corresponding single gutta-percha cone and sealer. The teeth were assigned to two retreatment groups (n = 18): group 1 360° rotational motion and group 2 reciprocating motion of ATR Tecnika motors (1310° clockwise and 578° counterclockwise). Retreatment procedure was performed with ProTaper Universal retreatment files with a sequence of D1-3 and ProTaper Universal F3 instruments. Total time required to remove filling material were recorded. Remaining filling material was examined under stereomicroscope at ×8 magnification. The data were analysed statistically using the Mann-Whitney U test, and testing was performed at 95 % confidence level (p < 0.05). There were no significant differences between the groups (p > 0.05) in terms of remaining filling material. The total time required for retreatment was shorter in 360° rotational motion group compared to reciprocating motion group (p < 0.05). Both continuous rotation and reciprocating motion showed similar effectiveness in terms of root canal filling material removal. Using ProTaper Universal retreatment instruments with reciprocating motion of ATR motor and conventional rotary motion have similar efficacy in root canal filling removal.

  13. The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece.

    PubMed

    Erdemir, A; Eldeniz, A U; Ari, H; Belli, S; Esener, T

    2007-05-01

    To determine the influence of various irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. One hundred and forty teeth with single canals and mature apices, scheduled for extraction for either periodontal or prosthetic reasons in 76 patients were used. Following informed written consent local anaesthesia was administered, access cavities were prepared and pulp tissue removed. The teeth were then randomly divided into seven groups according to the irrigating solutions used. The root canal length measurements were completed using the Tri Auto ZX handpiece with automatic reverse function in the presence of one or other of the following solutions: 0.9% saline, 2.5% NaOCl, 3% H(2)O(2), 0.2% chlorhexidine, 17% EDTA, Ultracaine D-S or in the absence of an irrigating solution (control). Files were immobilized in the access cavity with composite resin. After extraction, the apical regions of the teeth were exposed and the file tips examined under a stereomicroscope. Distances between the file tips and the apical constriction were measured (mm) and analysed using a one-way anova and post hoc Tukey test. Mean distances from the apical constriction to the file tip were longer in the 0.9% saline group (P<0.05). There was no statistically significant difference on file tip position between the other solutions. Tri Auto ZX gave reliable results with all irrigating solutions apart from in the presence of 0.9% saline.

  14. Rotary Mtwo system versus manual K-file instruments: efficacy in preparing primary and permanent molar root canals.

    PubMed

    Azar, Mohammad-Reza; Mokhtare, Maziar

    2011-01-01

    To compare the cleaning ability and preparation time of rotary instruments (Mtwo) and conventional manual instruments (K-file) in preparing primary and permanent molar root canals. Access cavities were prepared in 70 primary and 70 permanent teeth and India ink was injected into 120 canals of selected molars. The teeth were randomly divided into two main subgroups (n=20) and three control groups (n=10). In each of these main subgroups, either the manual instrument (K-file) or the rotary system (Mtwo) was used to prepare root canals. After cleaning the canals and clearing the teeth, dye removal was evaluated with the help of a stereomicroscope. In addition, the time needed for root canal preparation was recorded by a chronometer. Statistical analyses were done using the Kruskal-Wallis, Mann-Whitney and t tests. With regard to the cleaning ability of root canals, there were no significant differences between the K-file and Mtwo rotary system in primary and permanent teeth in the apical, middle or coronal third of the canals. Moreover, there were no significant differences between primary and permanent teeth prepared with K-files and rotary instruments. In all the groups, shorter times were recorded with the rotary technique. The working time was shorter in primary than in permanent teeth. The Mtwo rotary system showed acceptable cleaning ability in both primary and permanent teeth, and achieved results similar to those of K-files in less time.

  15. Influence of Er,Cr:YSGG laser treatment on the microtensile bond strength of adhesives to dentin.

    PubMed

    Cardoso, Marcio Vivan; Coutinho, Edurado; Ermis, R Banu; Poitevin, André; Van Landuyt, Kirsten; De Munck, Jan; Carvalho, Rubens C R; Lambrechts, Paul; Van Meerbeek, Bart

    2008-02-01

    In light of the concept of minimally invasive dentistry, erbium lasers have been considered as an alternative technique to the use of diamond burs for cavity preparation. The purpose of this study was to assess the bonding effectiveness of adhesives to Er,Cr:YSGG laser-irradiated dentin using irradiation settings specific for cavity preparation. Fifty-four midcoronal dentin surfaces, obtained from sound human molars, were irradiated with an Er,Cr:YSGG laser or prepared with a diamond bur using a high-speed turbine. One etch-and-rinse (Optibond FL/Kerr) and three self-etching adhesives (Adper Prompt L-Pop/3M ESPE, Clearfil SE Bond/Kuraray, and Clearfil S3 Bond/Kuraray) were used to bond the composite to dentin. The microtensile bond strength (microTBS) was determined after 24 h of storage in water at 37 degrees C. The Kruskal-Wallis test was used to determine pairwise statistical differences (p < 0.05). Prepared dentin surfaces, adhesive interfaces, and failure patterns were analyzed using a stereomicroscope and Field-emission gun Scanning Electron Microscopy (Feg-SEM). Significantly lower microTBS was observed to laser-irradiated than to bur-cut dentin (p < 0.05), irrespective of the adhesive employed. Feg-SEM photomicrographs of lased dentin revealed an imbricate patterned substrate and the presence of microcracks at the dentin surface. Morphological alterations produced by Er,Cr:YSGG laser-irradiation adversely influence the bonding effectiveness of adhesives to dentin.

  16. Influence of Hand Instrumentation and Ultrasonic Scaling on the Microleakage of various Cervical Restorations: An in vitro Study.

    PubMed

    Rohani, Bita; Barekatain, Mehrdad; Farhad, Shirin Z; Haghayegh, Navid

    2017-06-01

    In cervical lesions, various restorative materials can be inserted, which can be affected by the application of periodontal scalers. This study evaluated and compared the marginal seal of class V glass ionomer, composite resin, and amalgam restorations after subjecting them to hand instrumentation and ultrasonic scaling. In this experimental study, 30 sound human first premolars were selected. In each tooth, buccal and lingual cavities (4 mm mesiodistal width, 3 mm occlusogingival height, and 2 mm depth) were made. The teeth were randomly assigned to three groups of 10 teeth: (1) Glass ionomer group, (2) composite group, and (3) amalgam group. Teeth were subjected to thermocycling procedure for 1,000 cycles between 5 and 55°C water baths and a 1-minute dwell time. Then, each group was randomly subdivided: (1) Margins of 30 restorations were exposed to hand instrumentation procedures by applying 10 working strokes, (2) margins of 30 restorations were exposed to a periodontal tip mounted on a piezoelectric ultrasonic handpiece working at 25 kHz for 10 seconds. The specimens were serially sectioned mesiodistally. Each section was examined under a stereomicroscope. The extent of microleakage was ranked using a 0 to 4 scale at both occlusal and cervical margins of the restorations. Data were analyzed initially using the Kruskal-Wallis test, followed by multiple comparisons using the Mann-Whitney and Wilcoxon test. The type of restorative material had a significant influence on dye penetration, whether in the enamel margin or in the dentinal margin (p < 0.001). The microleakage of glass ionomer group was the highest. No statistical differences were found in dye penetration between scaling groups (hand instrumentation and ultrasonic scaling) (p > 0.05). Type of restorative material had a significant influence on microleakage. No statistical differences were found in dye penetration between scaling groups. The microleakage of glass ionomer restoration is greater than amalgam and composite restorations after subjecting them to hand instrumentation and ultrasonic scaling.

  17. Can low-fusing glass application affect the marginal misfit and bond strength of Y-TZP crowns?

    PubMed

    Antunes, Monize Carelli Felipe; Miranda, Jean Soares; Carvalho, Ronaldo Luís Almeida de; Carvalho, Rodrigo Furtado de; Kimpara, Estevão Tomomitsu; Assunção E Souza, Rodrigo Othávio de; Leite, Fabíola Pessôa Pereira

    2018-01-01

    To evaluate the effect of different surface treatments on the marginal misfit and retentive strength between Y-TZP crowns and an epoxy resin. Forty (40) epoxy resin (G10) abutments (height: 5mm, conicity: 60, finish line: large chamfer) with equal dimensions were milled and included in polyurethane to simulate the periodontal ligament. Next, 40 Y-TZP crowns (thickness: 1mm) were milled (Cerec in Lab) and randomly divided into four groups (n=10) according to the surface treatment: GS(glaze spray), GP(glaze powder/liquid), P(zirconia primer) and RS(tribochemical silica coating). The conditioned surfaces were cemented with dual self-adhesive cement, light cured and submitted to thermomechanical cycling (2x106, 100N, 4Hz, 5°/55°C). Marginal misfit was analyzed by a stereomicroscope and SEM. Retentive strength test was performed (1mm/min) until crown debonding. Glaze layer thickness was also performed to GS and GP groups. Marginal misfit data were analyzed by Kruskal Wallis and Dunn tests; one-way ANOVA and Tukey (5%) analyzed the tensile strength data. The marginal misfit of the GS (48.6±19.9μm) and GP (65.4±42.5μm) were statistically lower than the RS (96±62.9μm) and P (156±113.3μm) (p=0.001). The retentive strength of the GP (470.5±104.1N) and GS (416.8±170.2N) were similar to the P (342.1±109.7N), but statistically higher than those of the RS (208.9±110N). The GS and GP glaze layer was 11.64μm and 9.73μm respectively. Thus, glaze application promoted lower marginal discrepancy and higher retentive strength values than conventional techniques.

  18. Evaluation of tensile retention of Y-TZP crowns cemented on resin composite cores: effect of the cement and Y-TZP surface conditioning.

    PubMed

    Rippe, M P; Amaral, R; Oliveira, F S; Cesar, P F; Scotti, R; Valandro, L F; Bottino, M A

    2015-01-01

    This study evaluated the effect of the cement type (adhesive resin, self-adhesive, glass ionomer, and zinc phosphate) on the retention of crowns made of yttria-stabilized polycrystalline tetragonal zirconia (Y-TZP). Therefore, 108 freshly extracted molars were embedded in acrylic resin, perpendicular to their long axis, and prepared for full crowns: the crown preparations were removed and reconstructed using composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and Y-TZP copings were produced, which presented a special setup for the tensile testing. Cementation was performed with two adhesive resin cements (Multilink Automix, Ivoclar-Vivadent; RelyX ARC, 3M ESPE, St Paul, MN, USA), one self-adhesive resin cement (RelyX U100, 3M ESPE), one glass ionomer based cement (RelyX Luting, 3M ESPE), and one zinc phosphate cement (Cimento de Zinco, SS White, Rio de Janeiro, Brazil). For the resin cement groups, the inner surfaces of the crowns were subjected to three surface treatments: cleaning with isopropyl alcohol, tribochemical silica coating, or application of a thin low-fusing glass porcelain layer plus silanization. After 24 hours, all groups were subjected to thermocycling (6000 cycles) and included in a special device for tensile testing in a universal testing machine to test the retention of the infrastructure. After testing, the failure modes of all samples were analyzed under a stereomicroscope. The Kruskal-Wallis test showed that the surface treatment and cement type (α=0.05) affected the tensile retention results. The Multilink cement presented the highest tensile retention values, but that result was not statistically different from RelyX ARC. The surface treatment was statistically relevant only for the Multilink cement. The cement choice was shown to be more important than the crown surface treatment for cementation of a Y-TZP crown to a composite resin substrate.

  19. Shear bond strength of porcelain laminate veneers to enamel, dentine and enamel-dentine complex bonded with different adhesive luting systems.

    PubMed

    Öztürk, Elif; Bolay, Şükran; Hickel, Reinhard; Ilie, Nicoleta

    2013-02-01

    The aim of this study was to evaluate the shear bond strength of porcelain laminate veneers to 3 different surfaces by means of enamel, dentine, and enamel-dentine complex. One hundred thirty-five extracted human maxillary central teeth were used, and the teeth were randomly divided into 9 groups (n=15). The teeth were prepared with 3 different levels for bonding surfaces of enamel (E), dentine (D), and enamel-dentine complex (E-D). Porcelain discs (IPS e.max Press, Ivoclar Vivadent) of 2mm in thickness and 4mm in diameter were luted to the tooth surfaces by using 2 light-curing (RelyX Veneer [RV], 3M ESPE; Variolink Veneer [VV], Ivoclar Vivadent) and a dual-curing (Variolink II [V2], Ivoclar Vivadent) adhesive systems according to the manufacturers' instructions. Shear bond strength test was performed in a universal testing machine at 0.5mm/min until bonding failure. Failure modes were determined under a stereomicroscope, and fracture surfaces were evaluated with a scanning electron microscope. The data were statistically analysed (SPSS 17.0) (p=0.05). Group RV-D exhibited the lowest bond strength value (5.42±6.6MPa). There was statistically no difference among RV-D, V2-D (13.78±8.8MPa) and VV-D (13.84±6.2MPa) groups (p>0.05). Group VV-E exhibited the highest bond strength value (24.76±8.8MPa). The type of tooth structure affected the shear bond strength of the porcelain laminate veneers to the 3 different types of tooth structures (enamel, dentine, and enamel-dentine complex). When dentine exposure is necessary during preparation, enough sound enamel must be protected as much as possible to maintain a good bonding; to obtain maximum bond strength, preparation margins should be on sound enamel. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. A comparison of the relative efficacies of four hand and rotary instrumentation techniques during endodontic retreatment.

    PubMed

    Imura, N; Kato, A S; Hata, G I; Uemura, M; Toda, T; Weine, F

    2000-07-01

    The purpose of this study was to quantify the amount of remaining gutta-percha/scaler on the walls of root canals when two engine-driven instruments (Quantec and ProFile) and two hand instruments (K-file and Hedström file) were used to remove these materials. The amount of apically extruded debris and the time required for treatment were also recorded. One hundred extracted mandibular premolars were prepared using a modified step-back, flare technique and obturated with the lateral condensation technique. After repreparation with the test instruments, the specimens were cut transversally at the cervical, middle and apical thirds with steel discs and the three sections were split longitudinally. The amount of residual debris on the canal walls in each section was examined using a stereomicroscope. In all groups the cervical and middle thirds showed no debris. In the apical third, obturating material was observed in some specimens. No statistically significant difference was found between the two groups for incidence of debris, although the Hedström group showed a greater number of samples with remaining gutta-percha/sealer. When analysing dirty specimens only, there was a statistically significant difference between the four groups (P < 0.01) with the Hedström group having significantly less length of canal wall with remaining obturation material than the Quantec group. There was no significant difference amongst the groups for weight of extruded debris. However, there was a significant difference amongst the groups for mean treatment time with the Hedström file group requiring significantly less time than the Quantec group (P < 0.001); no significant differences were found between the other groups. Six instruments fractured in the Quantec group, four in the ProFile group, two in the Hedström group and two in the K-type group. The results showed that overall, all instruments may leave filling material inside the root canal. During retreatment there is a risk of instrument breakage, especially rotary instruments.

  1. Effect of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with different CAD-CAM technologies.

    PubMed

    Kocaağaoğlu, Hasan; Albayrak, Haydar; Kilinc, Halil Ibrahim; Gümüs, Hasan Önder

    2017-11-01

    The use of computer-aided design and computer-aided manufacturing (CAD-CAM) for metal-ceramic restorations has increased with advances in the technology. However, little is known about the marginal and internal adaptation of restorations fabricated using laser sintering (LS) and soft milling (SM). Moreover, the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with LS and SM is also unknown. The purpose of this in vitro study was to investigate the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic copings fabricated using the lost wax (LW), LS, and SM techniques. Ten LW, 10 LS, and 10 SM cobalt-chromium (Co-Cr) copings were fabricated for an artificial tooth (Frasaco GmbH). After the application of veneering ceramic (VITA VMK Master; VITA Zahnfabrik), the marginal and internal discrepancies of these copings were measured with a silicone indicator paste and a stereomicroscope at ×100 magnification after the first, second, and third clinical simulated ceramic firing cycles. Repeated measures 2-way ANOVA and the Fisher LSD post hoc test were used to evaluate differences in marginal and internal discrepancies (α=.05). Neither fabrication protocol nor repeated ceramic firings had any statistically significant effect on internal discrepancy values (P>.05). Marginal discrepancy values were also statistically unaffected by repeated ceramic firings (P>.05); however, the fabrication protocol had a significant effect on marginal discrepancy values (P<.001), with LW resulting in higher marginal discrepancy values than LS or SM (P<.05). Marginal discrepancy values did not vary between LS and SM (P>.05). All groups demonstrated clinically acceptable marginal adaptation after repeated ceramic firing cycles; however, the LS and SM groups demonstrated better marginal adaptation than that of LW group and may be appropriate clinical alternatives to LW. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Microleakage of Glass Ionomer-based Provisional Cement in CAD/CAM-Fabricated Interim Crowns: An in vitro Study.

    PubMed

    Farah, Ra'fat I; Al-Harethi, Naji

    2016-10-01

    The aim of this study was to compare in vitro the marginal microleakage of glass ionomer-based provisional cement with resin-based provisional cement and zinc oxide non-eugenol (ZONE) provisional cement in computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated interim restorations. Fifteen intact human premolars were prepared in a standardized manner for complete coverage of crown restorations. Interim crowns for the prepared teeth were then fabricated using CAD/CAM, and the specimens were randomized into three groups of provisional cementing agents (n = 5 each): Glass ionomer-based provisional cement (GC Fuji TEMP LT™), bisphenol-A-glycidyldimethacrylate (Bis-GMA)/ triethylene glycol dimethacrylate (TEGDMA) resin-based cement (UltraTemp® REZ), and ZONE cement (TempBond NE). After 24 hours of storage in distilled water at 37°C, the specimens were thermocycled and then stored again for 24 hours in distilled water at room temperature. Next, the specimens were placed in freshly prepared 2% aqueous methylene blue dye for 24 hours and then embedded in autopolymerizing acrylic resin blocks and sectioned in buccolingual and mesiodistal directions to assess dye penetration using a stereomicroscope. The results were statistically analyzed using a nonparametric Kruskal-Wallis test. Dunn's post hoc test with a Bonferroni correction test was used to compute multiple pairwise comparisons that identified differences among groups; the level of significance was set at p < 0.05. All groups exhibited marginal microleakage; the Bis-GMA/TEGDMA resin-based provisional cement demonstrated the lowest microleakage scores, which were statistically different from those of the glass ionomer-based provisional cement and the ZONE cement. The provisional cementing agents exhibited different sealing abilities. The Bis-GMA/TEGDMA resin-based provisional cement exhibited the most effective favorable sealing properties against dye penetration compared with the glass ionomer-based provisional cement and conventional ZONE cement. Newly introduced glass ionomer-based provisional cement proved to be inferior to resin-based provisional cement as far as marginal microleakage is concerned.

  3. In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models.

    PubMed

    Yamaguchi, Satoshi; Yamanishi, Yasufumi; Machado, Lucas S; Matsumoto, Shuji; Tovar, Nick; Coelho, Paulo G; Thompson, Van P; Imazato, Satoshi

    2018-01-01

    The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Fatigue testing showed significantly greater reliability for IN than EX (p<0.001). Fatigue crack initiation was primarily observed at implant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Comparative evaluation of different periods of enamel microabrasion on the microleakage of class V resin-modified glass ionomer and compomer restorations: An In vitro study.

    PubMed

    Bansal, Disha; Mahajan, Mrinalini

    2017-01-01

    The design of the class V cavity presents a clinical challenge in the field of adhesive dentistry as the margin placement is partially in enamel and partly in dentin, and the trouble associated with this design is the microleakage at the dentinal margin. When these restorations undergo microabrasion due to cosmetic reasons, this trouble aggravates to the significant levels. The aim of this study was the measurement of microleakage of class V glass ionomer restorations over two different periods of enamel microabrasion. This in vitro experimental study was conducted on 120 class V cavities which had been prepared on the buccal and lingual surfaces of 60 sound human premolars. One-half of the cavities were restored with the resin-modified glass ionomer cement (GIC) (60 cavities) and another half with the compomer (60 cavities). Finishing and polishing were performed. Then, the teeth were classified into six groups (n = 20). Microabrasion treatment was performed with Opaluster (Ultradent Product Inc., South Jordan, UT, USA) for 0 (control no treatment), 60 and 120 s. Then, teeth were thermocycled between 5°C and 55°C, immersed in rhodamine B solution (24 h), and sectioned longitudinally in buccolingual direction. Dye penetration was examined with stereomicroscope (×10). Microleakage scores were statistically analyzed. The mean occlusal margin scores and gingival margin scores were compared between all the groups using the Kruskal-Wallis test, Mann-Whitney U-test, Wilcoxon signed-rank test, and post hoc comparison. There was a significant difference between Group 1a, Group 2a, Group 1b, Group 2b, Group 1c, and Group 2c. Statistical analysis used in this study was Kruskal-Wallis test, Mann-Whitney U-test, Wilcoxon signed-rank test, and post hoc comparison. The least microleakage scores were observed in occlusal margins of control groups (without microabrasion). Moreover, in both restorations, the microleakage scores in occlusal margins were higher than gingival margins, and compoglass had less microleakage in occlusal and occlusal plus axial walls of class V cavities compared with resin-modified GIC. Whereas, the light-cured glass ionomer had less microleakage in the gingival and gingival plus axial walls of class V cavities when compared with compoglass. The least microleakage scores were observed in occlusal margins of control groups (without microabrasion). Moreover, in both restorations, the microleakage scores in occlusal margins were higher than gingival margins.

  5. Optical polymers for laser medical applications

    NASA Astrophysics Data System (ADS)

    Sultanova, Nina G.; Kasarova, Stefka N.; Nikolov, Ivan D.

    2016-01-01

    In medicine, optical polymers are used not only in ophthalmology but in many laser surgical, diagnostic and therapeutic systems. The application in lens design is determined by their refractive and dispersive properties in the considered spectral region. We have used different measuring techniques to obtain precise refractometric data in the visible and near-infrared spectral regions. Dispersive, thermal and other important optical characteristics of polymers have been studied. Design of a plastic achromatic objective, used in a surgical stereo-microscope at 1064 nm laser wavelength, is accomplished. Geometrical and wavefront aberrations are calculated. Another example of application of polymers is the designed all-mirror apochromatic micro-lens, intended for superluminescent diode fiber coupling in medical systems.

  6. Follicular unit transplantation: 2005.

    PubMed

    Bernstein, Robert M; Rassman, William R

    2005-07-01

    The recognition that the follicular unit is a discrete, anatomic and physiologic entity, and that preserving it through stereomicroscopic dissection is the best way to ensure the naturalness of the restoration, has brought hair transplantation into the twenty-first century. Issues yet to be resolved include determining the maximum density and number of grafts that can be used safely in a single session, deciding whether it is preferable to premake recipient sites or immediately place grafts into sites as they are made, and defining the precise role of follicular unit extraction. The essence of providing the best care for patients rests on proper patient selection, establishing realistic expectations, and using nonsurgical management for young persons who are just starting to thin.

  7. Laser-Marking Mechanism of Thermoplastic Polyurethane/Bi2O3 Composites.

    PubMed

    Zhong, Wei; Cao, Zheng; Qiu, Pengfei; Wu, Dun; Liu, Chunlin; Li, Huili; Zhu, He

    2015-11-04

    Using bismuth oxide (Bi2O3) as a laser-marking additive and thermoplastic polyurethane (TPU) as the matrix, TPU/Bi2O3 composite materials were prepared by melt blending in a torque rheometer. The sheet samples prepared from the TPU/Bi2O3 composites were treated in air by scanning with a neodymium-doped yttrium aluminum garnet (Nd: YAG) pulsed laser beam at a wavelength of 1064 nm. Compared with the pure TPU sample, the laser-marked composite samples exhibited differences in marking contrast as the Bi2O3 content increased from 0.1% to 1.0% based on stereomicroscope analysis. Scanning electron microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy, thermogravimetry analysis, and X-ray diffraction were used to characterize the laser-marked surface material of the composite samples. Furthermore, a mechanism for the laser-effected darkening of the TPU/Bi2O3 composites was proposed. The results herein indicated that the addition of the Bi2O3 laser-sensitive additive to TPU resulted in laser darkening of the TPU/Bi2O3 composites. The marking contrast and visual appearance of the surface of the TPU/Bi2O3 composites after laser irradiation was due to a synergistic effect consisting of carbonization via TPU pyrolysis and reduction of Bi2O3 to black bismuth metal.

  8. Patterns of infestation by chigger mites in four diurnal lizard species from a Restinga habitat (Jurubatiba) of southeastern Brazil.

    PubMed

    Cunha-Barros, M; Van Sluys, M; Vrcibradic, D; Galdino, C A; Hatano, F H; Rocha, C F

    2003-08-01

    We studied the parasitism by larvae of the chigger mite Eutrombicula alfreddugesi on the lizard community of Restinga de Jurubatiba, Rio de Janeiro State, Southeastern Brazil. We investigated the patterns of infestation (prevalence and intensity) of chigger mites in four sympatric lizards: Tropidurus torquatus, Mabuya agilis, M. macrorhyncha and Cnemidophorus littoralis. All lizards collected were checked for the presence of mites, which were counted under stereomicroscope. We tested the relationship between intensity of infestation and lizard body size for each species using regression analysis. The prevalences and mean intensities (+ one standard deviation) of infestation on each host species were, respectively: 100%; 86.4 + 94.6 in T. torquatus (n = 62); 100%; 20.9 + 9.3 in M. agilis (n = 7); 100%; 11.1 + 13.1 in M. macrorhyncha (n = 12); and 95.2%; 19.1 + 16.8 in C. littoralis (n = 21). Only for C. littoralis did body size significantly affect the intensity of infestation (r = 0.27, p = 0.02). For all lizard species, the body parts where chiggers occurred with the highest intensity were those of skin folds and joint regions.

  9. In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns

    PubMed Central

    Mulder, Riaan; Medhat, Rasha; Mohamed, Nadia

    2018-01-01

    Abstract Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100× stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 µm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p < .0001) over the other surfaces. The buccal surface was the only surface that had an appropriate supra-CEJ level with a significance of p < .0001. Conclusion: The marginal discrepancies occur during the trimming procedure and assessment of the gingival approximation of the SSC margin. The inspection of stainless steel crown adaptation and discrepancy is an essential clinical step. PMID:29536024

  10. Shear bond strength of indirect composite material to monolithic zirconia.

    PubMed

    Sari, Fatih; Secilmis, Asli; Simsek, Irfan; Ozsevik, Semih

    2016-08-01

    This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (α=.05). Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia.

  11. In vitro study of fracture load and fracture pattern of ceramic crowns: a finite element and fractography analysis.

    PubMed

    Campos, Roberto Elias; Soares, Carlos José; Quagliatto, Paulo S; Soares, Paulo Vinícius; de Oliveira, Osmir Batista; Santos-Filho, Paulo Cesar Freitas; Salazar-Marocho, Susana M

    2011-08-01

    This in vitro study investigated the null hypothesis that metal-free crowns induce fracture loads and mechanical behavior similar to metal ceramic systems and to study the fracture pattern of ceramic crowns under compressive loads using finite element and fractography analyses. Six groups (n = 8) with crowns from different systems were compared: conventional metal ceramic (Noritake) (CMC); modified metal ceramic (Noritake) (MMC); lithium disilicate-reinforced ceramic (IPS Empress II) (EMP); leucite-reinforced ceramic (Cergogold) (CERG); leucite fluoride-apatite reinforced ceramic (IPS d.Sign) (SIGN); and polymer crowns (Targis) (TARG). Standardized crown preparations were performed on bovine roots containing NiCr metal dowels and resin cores. Crowns were fabricated using the ceramics listed, cemented with dual-cure resin cement, and submitted to compressive loads in a mechanical testing machine at a 0.5-mm/min crosshead speed. Data were submitted to one-way ANOVA and Tukey tests, and fractured specimens were visually inspected under a stereomicroscope (20×) to determine the type of fracture. Maximum principal stress (MPS) distributions were calculated using finite element analysis, and fracture origin and the correlation with the fracture type were determined using fractography. Mean values of fracture resistance (N) for all groups were: CMC: 1383 ± 298 (a); MMC: 1691 ± 236 (a); EMP: 657 ± 153 (b); CERG: 546 ± 149 (bc); SIGN: 443 ± 126 (c); TARG: 749 ± 113 (b). Statistical results showed significant differences among groups (p < 0.05) represented by different lowercase letters. Metal ceramic crowns presented fracture loads significantly higher than the others. Ceramic specimens presented high incidence of fractures involving either the core or the tooth, and all fractures of polymer crown specimens involved the tooth in a catastrophic way. Based on stress and fractographic analyses it was determined that fracture occurred from the occlusal to the cervical direction. Within the limitations of this study, the results indicated that the use of ceramic and polymer crowns without a core reinforcement should be carefully evaluated before clinical use due to the high incidence of failure with tooth involvement. This mainly occurred for the polymer crown group, although the fracture load was higher than normal occlusal forces. High tensile stress concentrations were found around and between the occlusal loading points. Fractographic analysis indicated fracture originating from the load point and propagating from the occlusal surface toward the cervical area, which is the opposite direction of that observed in clinical situations. © 2011 by The American College of Prosthodontists.

  12. Observation and Quantification of Mating Behavior in the Pinewood Nematode, Bursaphelenchus xylophilus.

    PubMed

    Zhu, Najie; Bai, Liqun; Schütz, Stefan; Liu, Baojun; Liu, Zhenyu; Zhang, Xingyao; Yu, Hongshi; Hu, Jiafu

    2016-12-25

    A method for observing and quantifying the mating behavior of the pinewood nematode, Bursaphelenchus xylophilus, was established under a stereomicroscope. To improve the mating efficiency of B. Xylophilus and to increase the chances of mating observation, virgin adults were cultured and used for the investigation. Eggs were obtained by keeping the nematodes in water and allowing the females to lay eggs for 10 min. The second-stage juveniles (J2) were synchronized by incubating the eggs for 24 h at 25 °C in the dark, and the early J4 were obtained by culturing the J2 with grey mold, Botrytis cinerea, for another 52 h. At this time point, most J4 nematodes could be clearly distinguished as being male or female using their genital morphology. The male and female J4 were collected and cultured separately in two different Petri dishes for 24 h to get virgin adult nematodes. A virgin male and a virgin female were paired in a drop of water in the well of a concave slide. The mating behavior was filmed with a video recorder under a stereomicroscope. The whole period of the mating process was 82.8 ±3.91 min (mean ±SE) and could be divided into 4 different phases: searching, contacting, copulating, and lingering. The mean minutes of duration were 21.8 ± 2.0, 28.0 ± 1.9, 25.8 ± 0.7 and 7.2 ± 0.5, respectively. Eleven sub-behaviors were described: cruising, approaching, encountering, touching, hooping, locating, attaching, ejaculating, separating, quiescence, and roaming. Interestingly, obvious intra-sexual competition was observed when one female was grouped with 3 males or one male with 3 females. This protocol is useful and valuable, not only in investigating the mating behavior of B. xylophilus, but also in acting as a reference for ethological studies of other nematodes.

  13. Evaluation of different sterilization and disinfection methods on commercially made preformed crowns.

    PubMed

    Yilmaz, Y; Guler, C

    2008-12-01

    The aim of this study was to evaluate the changes caused by different sterilization or disinfection methods on the vestibular surface of four commercially made preformed crowns using stereomicroscopy and scanning electron microscopy (SEM). Preformed crowns (NuSmile Primary Anterior Crown (NSC), Kinder Krowns (KK), Pedo Pearls (PP) and polycarbonate crowns (PC)) were sterilized and/or disinfected by one of the following techniques: no sterilization or disinfection (G1 control group); steam autoclaving at 134 degrees C (30 psi) for 4 min (G2); steam autoclaving at 134 degrees C (30 psi) for 12 min (G3); steam autoclaving at 121 degrees C (15 psi) for 30 min (G4); and ultrasonication in a bath containing 4% Lysetol AF for 5 min at room temperature (chemical disinfection) (G5). Scanning electron micrographs of the crowns were taken before and after their sterilization or disinfection. The changes on the vestibular surface were then scored for the presence or absence of crazing, contour alteration, fracturing, and vestibular surface changes. The data were analyzed statistically using the chi-square test. No changes were observed before and after sterilization or disinfection in the stereomicroscopic evaluation of the vestibular surface of the crowns. However, all methods in which steam autoclaving was used to sterilize the crowns caused significant (P < 0.05) crazing and contour alterations of the vestibular surface of the crowns when they were examined by SEM. Chemical disinfection using an aldehyde-free disinfectant is the preferred method of disinfection for crowns that have been used previously in other dental patients.

  14. The incorporation of chlorhexidine in a two-step self-etching adhesive preserves dentin bond in vitro.

    PubMed

    Zhou, Jianfeng; Tan, Jianguo; Chen, Li; Li, Deli; Tan, Yao

    2009-10-01

    To investigate whether the incorporation of chlorhexidine in a two-step self-etching adhesive can preserve dentin bond strengths. Different amounts of 20% chlorhexidine digluconate were added directly to the primer of Clearfil SE Bond to prepare mixtures of four different concentrations of chlorhexidine: 0.05%, 0.1%, 0.5% and 1.0%. Sixteen extracted third molars were randomly divided into 4 groups. Each group corresponded to one of the four chlorhexidine concentrations. Each of the 16 teeth was sectioned into two halves. One half was bonded with Clearfil SE Bond without chlorhexidine, and the other half was bonded with Clearfil SE Bond containing different concentrations of chlorhexidine. Specimens were stored in 0.9% NaCl containing 0.02% sodium azide at 37 degrees C. Microtensile bond strengths were tested 24h after specimen preparation or 12 months later. The modes of fractures were examined under a stereomicroscope. Twelve-month storage resulted in significant bond strength reduction of all control groups (p<0.05). When incorporated in SE Bond primer, chlorhexidine preserved dentin bond in the 0.1%, 0.5% and 1.0% chlorhexidine group (p<0.05); in the 0.05% group, there is no statistical difference of bond strength between control group and experimental group tested at the 12-month period (p>0.05). When incorporated in the primer of Clearfil SE Bond, chlorhexidine can preserve dentin bond as long as the concentration of chlorhexidine in the primer is higher than or equal to 0.1%.

  15. Influence of caries infiltrant contamination on shear bond strength of different adhesives to dentin.

    PubMed

    Jia, Liuhe; Stawarczyk, Bogna; Schmidlin, Patrick R; Attin, Thomas; Wiegand, Annette

    2013-03-01

    To analyze whether the contamination with a caries infiltrant system impairs the adhesive performance of etch-and-rinse and self-etching adhesives on dentin. Dentin contamination with the caries infiltrant system (Icon, DMG) was simulated by applying either hydrochloric acid (15 % HCl, Icon Etch, 15 s), the resin infiltrant (Icon infiltrant, 4 min), or both prior to the application of the respective adhesives (each group n = 10). In the control groups, the etch-and-rinse adhesive (Optibond FL, Kerr) and the self-etching adhesive (iBOND Self Etch, Hereaus) were applied without former contamination with the infiltrant system. Additionally, the adhesive performance of the resin infiltrant alone was tested. Shear bond strength of a nano-hybrid composite was analyzed after thermocycling (5,000×, 5-55°C) of the specimens and analyzed by ANOVA/Scheffé post hoc tests (p < 0.05) and Weibull statistics. Failure mode was inspected under a stereomicroscope at × 25 magnification. Contamination with the resin infiltrant alone did not impair shear bond strength, while contamination with hydrochloric acid or with hydrochloric acid and the resin infiltrant reduced shear bond strength (MPa) of the adhesives (Optibond FL: 20.5 ± 3.6, iBOND Self Etch: 17.9 ± 2.6) significantly. Hydrochloric acid contamination increased the number of adhesive failures. The adhesive performance of the caries infiltrant system alone was insufficient. The contamination with the caries infiltrant system impaired the shear bond strength of conventional dental adhesives. Contamination of the caries infiltrant system on dentin should be avoided due to the detrimental effect of hydrochloric acid etching.

  16. Bonding of fibre-reinforced composite post to root canal dentin.

    PubMed

    Bell, Anna-Maria Le; Lassila, Lippo V J; Kangasniemi, Ilkka; Vallittu, Pekka K

    2005-08-01

    The aim of this study was to determine bonding properties of two types of fibre-reinforced composite (FRC) posts cemented into root canals of molars. Serrated titanium posts served as reference. Prefabricated carbon/graphite FRC posts with cross-linked polymer matrix and individually formed glass FRC posts with interpenetrating polymer network (IPN) polymer matrix were compared. The crowns of extracted third molars were removed and post space (diameter: 1.5mm) was drilled, etched and bonded. The posts were treated with dimethacrylate adhesive resin, light-polymerized and cemented with a dual-polymerizing composite resin luting cement. After thermocycling (6000x) the samples were cut into discs of thicknesses: 1, 2 and 4mm (n=12/group). Push-out force was measured by pushing the post from one end. Assessment of failure mode was made under a stereomicroscope (1, adhesive failure between post and cement; 2, cohesive failure of post-system; 3, adhesive failure between cement and dentin). The push-out force increased with increased height of dentin disc in all groups (ANOVA, p<0.001). In the 4mm thick dentin discs the individually formed glass FRC posts showed highest push-out force and the difference to that of the titanium posts was significant (ANOVA, p<0.001). The other differences were not statistically significant. None of the individually formed glass FRC posts showed adhesive failures between the post and the cement. Contrary to the other posts, there were no adhesive (post-cement) failures with the individually formed glass FRC posts, suggesting better interfacial adhesion of cement to these posts.

  17. Dentin pretreatment and adhesive temperature as affecting factors on bond strength of a universal adhesive system.

    PubMed

    Sutil, Bruna Gabrielle da Silva; Susin, Alexandre Henrique

    2017-01-01

    To evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and etch-and-rinse (ER) mode, adhesive temperature (20°C or 37°C) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm2 were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using two-way ANOVA and Tukey's test (α=5%). Interaction between treatment and temperature was statistically significant for SbU applied in self-etch technique. Both dentin treatments showed higher bond strength for ER mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE technique. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Dentin surface treatment with sodium bicarbonate air abrasion improves bond strength of SbU, irrespective of adhesive application mode, which makes this approach an alternative to increase adhesive performance of Scotchbond Universal Adhesive to dentin.

  18. Dentin pretreatment and adhesive temperature as affecting factors on bond strength of a universal adhesive system

    PubMed Central

    Sutil, Bruna Gabrielle da Silva; Susin, Alexandre Henrique

    2017-01-01

    Abstract Objectives: To evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Material and Methods: Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and etch-and-rinse (ER) mode, adhesive temperature (20°C or 37°C) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm2 were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using two-way ANOVA and Tukey's test (α=5%). Results: Interaction between treatment and temperature was statistically significant for SbU applied in self-etch technique. Both dentin treatments showed higher bond strength for ER mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE technique. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Conclusions: Dentin surface treatment with sodium bicarbonate air abrasion improves bond strength of SbU, irrespective of adhesive application mode, which makes this approach an alternative to increase adhesive performance of Scotchbond Universal Adhesive to dentin. PMID:29069151

  19. Effects of two soft drinks on shear bond strength and adhesive remnant index of orthodontic metal brackets.

    PubMed

    Sajadi, Soodabeh Sadat; Eslami Amirabadi, Gholamreza; Sajadi, Sepideh

    2014-07-01

    Bond failure of brackets during orthodontic treatment is a common problem; which results in treatment interference, increased treatment time and prolonged clinical time for rebonding of failed brackets. The purpose of this study was to evaluate the effects of Coca-Cola and a non-alcoholic beer on the shear bond strength and adhesive remnant index (ARI) of orthodontic metal brackets in vitro. Eighty intact human premolars were divided into two experimental groups of Coca-Cola and non-alcoholic beer (Istak), and a control group of artificial saliva. Over a period of thirty days, the test groups were immersed in the respective soft drinks for 5 minutes, twice a day. For the remainder of the time, they were kept in artificial saliva at 37°C. The control group was stored in artificial saliva during the experiment. All samples were subjected to shearing forces using Universal Testing Machine. ARI was determined with a stereomicroscope at ×12 magnification. The data of shear bond strength were statistically analyzed by one-way ANOVA and Tukey's Post-Hoc test and the data of ARI scores were analyzed by Kruskal-Wallis test. No significant difference was observed in ARIs of the three groups (P≤ 0.552). The shear bond strength of Coke group was significantly lower than that of the two other groups (P≤ 0.035); but there was no significant difference between the shear bond strength of Istak and the control group (P≤ 0.999). Coca-Cola decreased the shear bond strength of orthodontic brackets.

  20. Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study

    PubMed Central

    Helvacioglu-Yigit, Dilek; Aydemir, Seda; Yilmaz, Ayca

    2015-01-01

    The purpose of this study was to evaluate the presence of dentinal defects after root canal preparation with hand instruments and two different reciprocating instruments. Sixty freshly extracted mandibular incisor teeth were selected for this in vitro study. On the basis of root length, mesiodistal and buccolingual dimensions, the teeth were allocated into three identical experimental groups (n = 15) and one control group (n = 15). The teeth in the control group were left unprepared. The other groups were: stainless steel hand instruments, WaveOne® Primary instruments and RECIPROC® R25 instruments. The reciprocating instruments were used with a reciprocating gentle in-and-out motion in a torque-limited electric motor at the appropriate preset mode. Horizontal sections were made 3, 6 and 9 mm from the apex. Samples were stained with methylene blue and viewed through a stereomicroscope. The presence of dentinal defects (fractures, incomplete cracks and craze lines) and their locations were investigated by two endodontists. These data were analysed statistically by Fisher's exact and chi-square tests. No defects were observed in the unprepared group. All instruments caused dentinal defects, with no significant differences between the instrument systems. All experimental groups demonstrated significantly more defects at the 3-mm level in comparison with the unprepared group (p = 0.032). At the other levels, there was no significant difference between the experimental groups and the control group. The use of hand or reciprocating instruments could induce the formation of dentinal defects during root canal preparation. PMID:26019654

  1. Effect of protective coating on marginal integrity of nanohybrid composite during bleaching with carbamide peroxide: A microleakage study.

    PubMed

    Kumar, A Ashok; Hariharavel, V P; Narayanan, Ashwin; Murali, S

    2015-01-01

    The aim of the study was to evaluate the microleakage on the marginal integrity of nanohybrid composite during bleaching with carbamide peroxide after applying a protective coating of G-Coat plus (GC, Japan). Class V cavities were prepared and restored with nanohybrid composite restoration in 60 freshly extracted noncarious premolars extracted for orthodontic reasons. Then they were divided into 3 groups. Group 1 - bleaching with carbamide peroxide without G coat plus (n = 20), Group 2 - bleaching with carbamide peroxide with G-Coat plus (n = 20), Group 3 - without bleaching procedure (n = 20) (control group). In Group 2, G coat plus was applied over the restorative surface and margins. Then all teeth in Groups 1 and 2 were taken and mounted in dental stone. Bleaching trays were custom fabricated over the cast with the help of a heated vacuum-forming machine. 10% carbamide peroxide (opalescence PF) was applied over the tooth, and the bleaching process was done for about 2 weeks. Then all samples underwent thermocycling and were then immersed in the 2% methylene blue solution for 24 h and observed under a stereomicroscope to evaluate the amount of dye penetration. Data were compared using Kruskal-Wallis test and Mann-Whitney test using SPSS Inc.; Chicago, IL, USA, Version 17.0. Mann-Whitney test shows that the difference in microleakage between Group 1-Group 2 and Group 2-Group 3 is statistically significant (P < 0.05). Significant reduction in microleakage was seen in Group 2 when compared to other groups.

  2. Effect of Diamond Bur Grit Size on Composite Repair.

    PubMed

    Valente, Lisia L; Silva, Manuela F; Fonseca, Andrea S; Münchow, Eliseu A; Isolan, Cristina P; Moraes, Rafael R

    2015-06-01

    This study investigated the effect of diamond bur grit size on the repair bond strength of fresh and aged resin composites. Blocks of microhybrid composite (Opallis, FGM) were stored in distilled water at 37°C for 24 h (fresh composite) or subjected to 5000 thermal cycles (aged composite). The surfaces were roughened using diamond-coated, flame-shaped carbide burs with medium grit (#3168), fine grit (#3168F), or extra-fine grit (#3168FF). The control group underwent no surface treatment. Surface roughness, water contact angle, and surface topography by scanning electron microscopy (SEM) were evaluated (n = 3). Samples were restored with resin composite and sectioned into beam-shaped specimens, which were subjected to microtensile bond testing. Failure modes were classified using a stereomicroscope. Data were statistically analyzed using the Student- Newman-Keuls test and two-way ANOVA, with significance set at p < 0.05. Higher surface roughness was observed for groups treated with the medium- and fine-grit burs; aged composites were rougher than fresh composites. The water contact angle formed on the aged composite was lower than that on the fresh composite. The highest repair bond strength was observed for the fine-grit bur group, and the lowest was recorded for control. Interfacial failures were more predominant. SEM images showed that the surfaces treated with fine- and extra-fine-grit burs had a more irregular topography. Surface roughening of fresh or aged resin composites with diamond burs improved retention of the repair material. Fine-grit burs generally performed better than medium- and extra-fine-grit burs.

  3. Marginal integrity of low-shrinkage and methacrylate-based composite resins: Effect of three different hemostatic agents

    PubMed Central

    Khoroushi, Maryam; Sahraneshin-Samani, Mahsa

    2016-01-01

    Background Moisture control is very important in restorative procedures in dentistry. Use of hemostatic agents helps control moisture; however, they might result in changes on enamel and dentin surfaces, affecting composite resin bond quality. The aim of this in vitro study was to evaluate the marginal microleakage of two different composite resins with the use of three different hemostatic agents. Material and Methods Standardized Class V cavities were prepared on the buccal and lingual surfaces of 48 premolars with cervical margins 1 mm apical to the cementoenamel junction (CEJ). The samples were randomly divided into 8 groups. In groups 1 to 4, an etch-and-rinse adhesive (Adper Single Bond) was applied as the bonding system, followed by exposure to different hemostatic agent: group 1: no hemostatic agent (control); group 2: ViscoStat; group 3: ViscoStat Clear; and group 4: trichloracetic acid, as hemostatic agents. The cavities were restored with Z-250 composite resin. In group 5 to 8 Silorane System Adhesive (Filtek P90 Adhesive) was applied as a bonding agent, followed by exposure to different hemostatic agents in a manner similar to that in groups 1to 4. The cavities were restored with Filtek P90, a low-shrinkage composite resin. The samples in each group were evaluated for dye penetration under a stereomicroscope at ×36 after 24 hours and a 500-round thermocycling procedure at enamel and dentin margins. Statistical analysis was carried out using Kruskal-Wallis and Mann-Whitney tests (α=0.05). Results Z-250 composite resin exhibited significantly higher dentin microleakage scores compared to Filtek P90 (P = 0.004). Trichloracetic acid increased dentin microleakage with Filtek P90 (P=0.033). Conclusions Under the limitations of this in vitro study, application of hemostatic agents did not affect microleakage of the two tested composite resins except for trichloracetic acid that increased marginal microleakage when used with Filtek P90. Key words:Composite resin, dental leakage, hemostatics, silorane system adhesive. PMID:27034759

  4. Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns.

    PubMed

    Tamac, Ece; Toksavul, Suna; Toman, Muhittin

    2014-10-01

    Metal ceramic crowns are widely used in clinical practice, but comparisons of the clinical adaptation of restorations made with different processing techniques are lacking. The purpose of this study was to compare the clinical marginal and internal adaptation of metal ceramic crowns fabricated with 3 different techniques: computer-aided design and computer-aided manufacturing (CAD/CAM) milling (CCM), direct metal laser sintering (DMLS), and traditional casting (TC). Twenty CCM, 20 DMLS, and 20 TC metal ceramic crowns were fabricated for 42 patients. Before luting the crowns, silicone replicas were obtained to measure marginal gap and internal adaptation that was evaluated at 3 regions: axial wall, axio-occlusal angle, and occlusal surface. Measurements were made with a reflected light binocular stereomicroscope at 20× magnification and analyzed with 1-way analysis of variance (ANOVA) and the Bonferroni post hoc test (α=.05). The mean marginal gap values were 86.64 μm for CCM, 96.23 μm for DMLS, and 75.92 μm for TC. The means at the axial wall region were 117.5 μm for the CCM group, 139.02 μm for the DMLS group, and 121.38 μm for the TC group. One-way ANOVA revealed no statistically significant differences among the groups for measurements at the marginal gap (P=.082) and the axial wall region (P=.114). The means at the axio-occlusal region were 142.1 μm for CCM, 188.12 μm for DMLS, and 140.63 μm for TC, and those at the occlusal surface region were 265.73 μm for CCM, 290.39 μm for DMLS, and 201.09 μm for TC. The mean values of group DMLS were significantly higher at the axio-occlusal region and the occlusal surface region than those of other groups (P<.05). CCM, DMLS and TC metal ceramic crowns performed similarly in terms of clinical marginal and axial wall adaptation. The cement film thickness at the occlusal region and axio-occlusal region were higher for DMLS crowns. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Influence of porcelain firing and cementation on the marginal adaptation of metal-ceramic restorations prepared by different methods.

    PubMed

    Kaleli, Necati; Saraç, Duygu

    2017-05-01

    Marginal adaptation plays an important role in the survival of metal-ceramic restorations. Porcelain firings and cementation may affect the adaptation of restorations. Moreover, conventional casting procedures and casting imperfections may cause deteriorations in the marginal adaptation of metal-ceramic restorations. The purpose of this in vitro study was to compare the marginal adaptation after fabrication of the framework, porcelain application, and cementation of metal-ceramic restorations prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and LaserCUSING, a direct process powder-bed system. Alterations in the marginal adaptation of the metal frameworks during the fabrication stages and the precision of fabrication methods were evaluated. Forty-eight metal dies simulating prepared premolar and molar abutment teeth were fabricated to investigate marginal adaptation. They were divided into 4 groups (n=12) according to the fabrication method used (group C serving as the control group: lost-wax method; group M: milling method; group LS: DMLS method; group DP: direct process powder-bed method). Sixty marginal discrepancy measurements were recorded separately on each abutment tooth after fabrication of the framework, porcelain application, and cementation by using a stereomicroscope. Thereafter, each group was divided into 3 subgroups according to the measurements recorded in each fabrication stage: subgroup F (framework), subgroup P (porcelain application), and subgroup C (cementation). Data were statistically analyzed with univariate analysis of variance (followed by 1-way ANOVA and Tamhane T2 test (α=.05). The lowest marginal discrepancy values were observed in restorations prepared by using the direct process powder-bed method, and this was significantly different (P<.001) from the other methods. The highest marginal discrepancy values were recorded after the cementation procedure in all groups. The results showed that the direct process powder-bed method is quite successful in terms of marginal adaptation. The marginal discrepancy increased after porcelain application and cementation. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Comparative evaluation of self-etching primers and phosphoric acid effectiveness on composite to enamel bond: an in vitro study.

    PubMed

    Patil, Basanagouda S; Rao, Bk Raghavendra; Sharathchandra, Sm; Hegde, Reshma; Kumar, G Vinay

    2013-09-01

    The aim of the present study was to investigate the effectiveness of the one total-etch self-priming adhesive, one two-step self-etching primer adhesive, and one 'all-in-one' self-etching adhesive system on the adhesion of a resin composite to enamel. Thirty-six freshly extracted human mandibular molars were selected for this study. A fat area about 5 mm in diameter was created on the exposed mesial surface of enamel of each tooth by moist grinding with 320, 420 and 600 grit silicon carbide paper. Twelve teeth were randomly assigned into three groups. In group 1, Adper Easy One (3M ESPE), a one step self-etching primer adhesive was applied and light curing unit for 10 seconds. In group 2, Adper SE Plus, a two-step self-etching primer with bottle A containing the aqueous primer and bottle B containing the acidic adhesive was applied and light cured for 10 seconds. Group 3 (control)-etchant 37% phosphoric acid is applied to the surface for 15 seconds and rinsed with water and air dried and adhesive (single bond 2) is applied to the surface and tube is placed and light cured for 20 seconds. Composite material (Z350) was placed in the tube and light cured for 40 seconds in all the groups. Bond strength testing was done using universal testing machine at the enamel-composite interface. The debonded enamel surface was evaluated in stereomicroscope to assess the cohesive, adhesive or mixed fracture. Data was statistically analyzed by one way analysis of variance (ANOVA). Group 1 performed least among all groups with a mean score of 19.46 MPa. Group 2 had a mean score of 25.67 MPa. Group 3 had a mean score of 27.16 MPa. Under the conditions of this in vitro study, the bond strength values of the two-step self-etching primer systems tested were similar to the total-etch. And, one step self-etching primers have lower bond strength compared to the total-etch.

  7. Dental cementum in age estimation: a polarized light and stereomicroscopic study.

    PubMed

    Kasetty, Sowmya; Rammanohar, M; Raju Ragavendra, T

    2010-05-01

    Dental hard tissues are good candidates for age estimation as they are less destructive and procedures to determine age can be easily performed. Although cementum annulations and cementum thickness are important parameters in this regard, they are seldom used. This study was undertaken to review the methods, difficulties in execution of techniques, and accuracy of cementum thickness and annulations in estimating the age. Unstained and stained ground sections of tooth were used to measure cemental thickness and count cemental annulations based on which age was estimated and was compared with known age. Although there was positive relation between cemental thickness and annulations with age, only in 1-1.5% of cases, age could be predicted with accuracy.

  8. KSC-2010-4526

    NASA Image and Video Library

    2010-08-28

    CAPE CANAVERAL, Fla. -- At the Astronaut Hall of Fame near the Kennedy Space Center Visitor Complex in Florida, fifth- through eighth-grade students and their parents participate in the Materials Science Laboratory exhibit by using stereomicroscopes and viewing 3-D scanning electron microscope images during the last NASA family education night event. Other activities included "gee-whiz" presentations, astronaut appearances, a hovercraft, vortex cannon and alternative fuel vehicles, which promote science, technology, engineering and mathematics (STEM) education. The event is part of NASA's Summer of Innovation initiative to provide interactive learning experiences to middle school students nationwide during the summer months. The program is a cornerstone of the Educate to Innovate campaign announced by President Barack Obama in November 2009. Photo credit: NASA/Charisse Nahser

  9. The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

    PubMed

    Ates, Sabit Melih; Yesil Duymus, Zeynep; Caglar, Ipek; Hologlu, Bilal

    2017-11-01

    This in vitro study investigated the marginal fit of metal and zirconia copings before and after veneering on dies with shoulder/chamfer (s/c) finish lines. Using CAD/CAM, ten (n = 10) each s/c zirconia (NZ) copings and ten (n = 10) each s/c metal (MM) copings were generated. As controls, ten (n = 10) each s/c zirconia copings were copy-milled (ZZ) and ten (n = 10) each s/c metal copings were cast (CC). The vertical marginal discrepancy of the copings was measured at 20 predefined spots of the circular shoulder and chamfer finish lines in microns (μm) before and after a first and a second veneering firing using a stereomicroscope at ×40 magnification. Data were statistically analyzed, and the comparisons of CAD/CAM-milled (NZ, MM), copy-milled (ZZ), and cast (CC) copings before and after veneering were made at a significance level of p < 0.05. Gap width at s/c finish lines of ZZ was (91 ± 11/100 ± 28) and increased significantly (109 ± 21/141 ± 18) after the first firing (ZZ1). NZ showed significantly smaller gaps than ZZ (36 ± 6/46 ± 12) and (NZ1) after the first firing (61 ± 16/71 ± 29). Gap widths of CC groups (36 ± 8/25 ± 4) were not significantly different from NZ but were significantly lower after the (CC1) first veneering firing (40 ± 8/42 ± 7). MM copings showed gap values similar to NZ. Second firings did not significantly increase gaps in all groups except ZZ2 of chamfer finish line. Veneering increased the marginal gap width of copings. Within the limits of this in vitro study, aesthetic ceramic veneering of CAD/CAM-generated copings caused a statistically significant but tolerable loss of marginal fit precision.

  10. Gas chromatography/matrix-isolation apparatus

    DOEpatents

    Reedy, G.T.

    1986-06-10

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring. 10 figs.

  11. Gas chromatography/matrix-isolation apparatus

    DOEpatents

    Reedy, Gerald T.

    1986-01-01

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring.

  12. [Comparative evaluation of the marginal accuracy of single crowns fabricated computer using aided design/computer aided manufacturing methods, self-curing resin and Luxatemp].

    PubMed

    Jianming, Yuan; Ying, Tang; Feng, Pan; Weixing, Xu

    2016-12-01

    This study aims to compare the marginal accuracy of single crowns fabricated using self-curing resin, Luxatemp, and computer aided design/computer aided manufacturing (CAD/CAM) methods in clinical application. A total of 30 working dies, which were obtained from 30 clinical teeth prepared with full crown as standard, were created and made into 30 self-curing resin, Luxatemp, and CAD/CAM single crowns. The restorations were seated on the working dies, and stereomicroscope was used to observe and measure the thickness of reference points. One-way analysis of variance, which was performed using SPSS 19.0 software package, compared the marginal gap widths of self-curing resin, Luxatemp, and CAD/CAM provisional crowns. The mean marginal gap widths of the fabricated self-curing resin, Luxatemp, and CAD/CAM were (179.06±33.24), (88.83±9.56), and (43.61±7.27) μm, respectively. A significant difference was observed among the three provisional crowns (P<0.05). The marginal gap width of CAD/CAM provisional crown was lower than that of the self-curing resin and Luxatemp. Thus, the CAD/CAM provisional crown offers a better remediation effect in clinical application.

  13. Effect of Fractal Dimension on the Strain Behavior of Particulate Media

    NASA Astrophysics Data System (ADS)

    Altun, Selim; Sezer, Alper; Goktepe, A. Burak

    2016-12-01

    In this study, the influence of several fractal identifiers of granular materials on dynamic behavior of a flexible pavement structure as a particulate stratum is considered. Using experimental results and numerical methods as well, 15 different grain-shaped sands obtained from 5 different sources were analyzed as pavement base course materials. Image analyses were carried out by use of a stereomicroscope on 15 different samples to obtain quantitative particle shape information. Furthermore, triaxial compression tests were conducted to determine stress-strain and shear strength parameters of sands. Additionally, the dynamic response of the particulate media to standard traffic loads was computed using finite element modeling (FEM) technique. Using area-perimeter, line divider and box counting methods, over a hundred grains for each sand type were subjected to fractal analysis. Relationships among fractal dimension descriptors and dynamic strain levels were established for assessment of importance of shape descriptors of sands at various scales on the dynamic behavior. In this context, the advantage of fractal geometry concept to describe irregular and fractured shapes was used to characterize the sands used as base course materials. Results indicated that fractal identifiers can be preferred to analyze the effect of shape properties of sands on dynamic behavior of pavement base layers.

  14. Effect of two storage solutions on surface topography of two root-end fillings.

    PubMed

    Asgary, Saeed; Eghbal, Mohammad Jafar; Parirokh, Masoud; Ghoddusi, Jamileh

    2009-12-01

    The effect of different storage solutions on surface topography of mineral trioxide aggregate (MTA) and new experimental cement (NEC) as root-end fillings was investigated. Twenty-four single-rooted teeth were cleaned, shaped and obturated in a same manner. After root-end resection, 3-mm deep root-end cavities were ultrasonically prepared. Samples were randomly divided into four test groups (A1-A2-B1-B2, n = 6). Root-end cavities in groups A and B were filled with MTA and NEC, respectively, and were then stored in 100% humidity for 24 h. The samples of groups 1 and 2 were, respectively, immersed in normal saline (NS) and phosphate buffer saline solutions for 1 week. The samples were imaged under stereomicroscope before and after immersion and were then investigated and analysed by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDXA). Results showed significant difference among studied groups. Surface topography of all samples was altered by crystal formation and precipitation on root-end fillings except for group A1 (MTA-NS). SEM and EDXA results showed that the composition and structure of precipitated crystals were comparable with that of standard hydroxyapatite. It was concluded that biocompatibility, sealing ability, and cementogenic activity of MTA and probably NEC may be attributed to this fundamental bioactive reaction.

  15. Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study.

    PubMed

    Pompa, Giorgio; Di Carlo, Stefano; De Angelis, Francesca; Cristalli, Maria Paola; Annibali, Susanna

    2015-01-01

    This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n = 20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P < 0.05) were observed between group 3 and the other groups. The marginal opening was smallest with Co-Cr alloy substructures, while the shoulder opening was smallest with Ni-Cr alloy substructures. Within the limitations of this study, the marginal fit of an FDP is better with rapid prototyping (RP) via SLM than conventional manufacturing systems.

  16. Accuracy of the One-Stage and Two-Stage Impression Techniques: A Comparative Analysis

    PubMed Central

    Jamshidy, Ladan; Faraji, Payam; Sharifi, Roohollah

    2016-01-01

    Introduction. One of the main steps of impression is the selection and preparation of an appropriate tray. Hence, the present study aimed to analyze and compare the accuracy of one- and two-stage impression techniques. Materials and Methods. A resin laboratory-made model, as the first molar, was prepared by standard method for full crowns with processed preparation finish line of 1 mm depth and convergence angle of 3-4°. Impression was made 20 times with one-stage technique and 20 times with two-stage technique using an appropriate tray. To measure the marginal gap, the distance between the restoration margin and preparation finish line of plaster dies was vertically determined in mid mesial, distal, buccal, and lingual (MDBL) regions by a stereomicroscope using a standard method. Results. The results of independent test showed that the mean value of the marginal gap obtained by one-stage impression technique was higher than that of two-stage impression technique. Further, there was no significant difference between one- and two-stage impression techniques in mid buccal region, but a significant difference was reported between the two impression techniques in MDL regions and in general. Conclusion. The findings of the present study indicated higher accuracy for two-stage impression technique than for the one-stage impression technique. PMID:28003824

  17. Accuracy of the One-Stage and Two-Stage Impression Techniques: A Comparative Analysis.

    PubMed

    Jamshidy, Ladan; Mozaffari, Hamid Reza; Faraji, Payam; Sharifi, Roohollah

    2016-01-01

    Introduction . One of the main steps of impression is the selection and preparation of an appropriate tray. Hence, the present study aimed to analyze and compare the accuracy of one- and two-stage impression techniques. Materials and Methods . A resin laboratory-made model, as the first molar, was prepared by standard method for full crowns with processed preparation finish line of 1 mm depth and convergence angle of 3-4°. Impression was made 20 times with one-stage technique and 20 times with two-stage technique using an appropriate tray. To measure the marginal gap, the distance between the restoration margin and preparation finish line of plaster dies was vertically determined in mid mesial, distal, buccal, and lingual (MDBL) regions by a stereomicroscope using a standard method. Results . The results of independent test showed that the mean value of the marginal gap obtained by one-stage impression technique was higher than that of two-stage impression technique. Further, there was no significant difference between one- and two-stage impression techniques in mid buccal region, but a significant difference was reported between the two impression techniques in MDL regions and in general. Conclusion . The findings of the present study indicated higher accuracy for two-stage impression technique than for the one-stage impression technique.

  18. Shear bond strength of indirect composite material to monolithic zirconia

    PubMed Central

    2016-01-01

    PURPOSE This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (α=.05). RESULTS Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). CONCLUSION Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia. PMID:27555895

  19. Is there a real danger of concealing gunshot residue (GSR) particles by skin debris using the tape-lift method for sampling GSR from hands?

    PubMed

    Zeichner, A

    2001-11-01

    Experiments were carried out to assess the danger of concealing GSR particles by skin debris using the tape-lift method for sampling GSR from hands. Thirty discrete spherical particles (from GSR and from the debris of oxygen cutting of steel) sized from 8 to 30 microns were mounted on a double-side adhesive coated stubs in known locations using a stereomicroscope. These stubs were then used for dabbing hands 50 times. Some of the particles or parts thereof were covered by skin flakes, however, all particles could be detected using the backscattered electron image (BEI) in the scanning electron microscope (SEM). Also, all could be identified by the energy dispersive X-ray spectroscopy (EDX).

  20. Influence of ultrasonic and sonic activation of epoxy-amine resin-based sealer on penetration of sealer into lateral canals.

    PubMed

    Arslan, Hakan; Abbas, Aneesh; Karatas, Ertugrul

    2016-11-01

    The aim of this study was to evaluate the efficacy of sonic and ultrasonic activation of epoxy-amine resin-based root canal sealer (2Seal; VDW GmbH, München, Germany) on penetration of the sealer into lateral canals compared to non-activated filling. Thirty-six single-rooted human anterior teeth were decoronated and prepared, using the ProTaper rotary system (Dentsply Maillefer, Ballaigues, Switzerland) to F4. After the completion of the clearing procedures, lateral canals were created at 2, 4, and 6 mm from the working length. The specimens were randomly divided into a control group (non-activated sealer application) and two experimental groups that received a sealer application with either sonic or ultrasonic activation. The root canals were filled using cold lateral compaction and images were obtained from each lateral canals at 40× magnification using a stereomicroscope. The sealer penetration was evaluated using a four-grade scoring system. The data were evaluated statistically using the Kruskal-Wallis and Mann-Whitney U tests with a 95 % confidence level (P = 0.05). The ultrasonic activation resulted in a better sealer penetration compared with the non-activated and sonically activated groups (P < 0.001). Sonic activation also resulted in better sealer penetration compared to the non-activated group (P < 0.001). The use of the ultrasonic activation of an epoxy-amine resin-based sealer promoted greater sealer penetration into the lateral canals. Sonic activation was not effective as ultrasonic activation, but was more effective than the non-activated group. The ultrasonic activation of an epoxy-amine resin-based sealer could be beneficial in filling procedures.

  1. Effectiveness of various irrigation protocols for the removal of calcium hydroxide from artificial standardized grooves

    PubMed Central

    GOKTURK, Hakan; OZKOCAK, Ismail; BUYUKGEBIZ, Feyzi; DEMIR, Osman

    2017-01-01

    Abstract Objective The aim of this study was to investigate the ability of laser-activated irrigation (LAI), XP-endo Finisher, CanalBrush, Vibringe, passive ultrasonic irrigation (PUI), and conventional syringe irrigation systems on the removal of calcium hydroxide (CH) from simulated root canal irregularities. Material and Methods The root canals of one hundred and five extracted single-rooted teeth were instrumented using Reciproc rotary files up to size R40. The teeth were split longitudinally. Two of the three standard grooves were created in the coronal and apical section of one segment, and another in the middle part of the second segment. The standardized grooves were filled with CH and the root halves were reassembled. After 14 days, the specimens were randomly divided into 7 experimental groups (n=15/group). CH was removed as follows: Group 1: beveled needle irrigation; Group 2: double side-vented needle irrigation; Group 3: CanalBrush; Group 4: XP-endo Finisher; Group 5: Vibringe; Group 6: PUI; Group 7: LAI. The amount of remaining CH in the grooves was scored under a stereomicroscope at 20× magnification. Statistical evaluation was performed using Kruskal–Wallis and Bonferroni-Correction Mann–Whitney U tests. Results Groups 1 and 2 were the least efficient in eliminating CH from the grooves. Groups 6 and 7 eliminated more CH than the other protocols; however, no significant differences were found between these two groups (P>.05). Conclusions Nevertheless, none of the investigated protocols were able to completely remove all CH from all three root regions. LAI and PUI showed less residual CH than the other protocols from artificial grooves. PMID:28678948

  2. Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation.

    PubMed

    Pesce, Paolo; Pera, Francesco; Setti, Paolo; Menini, Maria

    To evaluate the accuracy and precision of a digital scanner used to scan four implants positioned according to an immediate loading implant protocol and to assess the accuracy of an aluminum framework fabricated from a digital impression. Five master casts reproducing different edentulous maxillae with four tilted implants were used. Four scan bodies were screwed onto the low-profile abutments, and a digital intraoral scanner was used to perform five digital impressions of each master cast. To assess trueness, a metal framework of the best digital impression was produced with computer-aided design/computer-assisted manufacture (CAD/CAM) technology and passive fit was assessed with the Sheffield test. Gaps between the frameworks and the implant analogs were measured with a stereomicroscope. To assess precision, three-dimensional (3D) point cloud processing software was used to measure the deviations between the five digital impressions of each cast by producing a color map. The deviation values were grouped in three classes, and differences were assessed between class 2 (representing lower discrepancies) and the assembled classes 1 and 3 (representing the higher negative and positive discrepancies, respectively). The frameworks showed a mean gap of < 30 μm (range: 2 to 47 μm). A statistically significant difference was found between the two groups by the 3D point cloud software, with higher frequencies of points in class 2 than in grouped classes 1 and 3 (P < .001). Within the limits of this in vitro study, it appears that a digital impression may represent a reliable method for fabricating full-arch implant frameworks with good passive fit when tilted implants are present.

  3. In Vitro Comparison of Gutta-Percha Removal with H-File and ProTaper with or without Chloroform

    PubMed Central

    Khalilak, Zohreh; Vatanpour, Mehdi; Dadresanfar, Bahareh; Moshkelgosha, Pouneh; Nourbakhsh, HamidReza

    2013-01-01

    Introduction Removal of root filling materials is one of the key steps in success of root canal retreatment. The purpose of this study was to evaluate the efficacy of H-File and ProTaper with or without chloroform in the removal of gutta-percha during retreatment of mandibular premolars. Materials and Methods Sixty mandibular premolars with one canal, and curvatures less than 30 degrees were used in this experimental study. They were instrumented with K-files and laterally obturated with condensed gutta-percha using AH26 as the sealer and were stored in 100% humidity at 37°C for 2 weeks. The teeth were randomly divided into four groups of 15 teeth each. Removal of gutta-percha was performed with H-File and ProTaper. All techniques were used with or without chloroform. The teeth were split longitudinally and the area of remaining gutta-percha/sealer on the root canal wall was explored under stereomicroscope. Retreatment time duration was also recorded for each sample. Data were analyzed statistically by Two-way ANOVA, t-test and Tukey’s. Results In all groups, no significant difference was found in remaining gutta-percha and sealer with or without using chloroform, but chloroform shortened the time of retreatment. ProTaper left significantly less remaining filling materials than H-File (P<0.05). Retreatment time was significantly different between the studied groups (P<0.001). Conclusion ProTaper Ni-Ti instruments proved to be more efficient and time-saving devices for removal of gutta-percha compared to H-File in canals with no or slight curvature. PMID:23413203

  4. The Effect of Cavity Design on Fracture Resistance and Failure Pattern in Monolithic Zirconia Partial Coverage Restorations - An In vitro Study.

    PubMed

    Harsha, Madhavareddy Sri; Praffulla, Mynampati; Babu, Mandava Ramesh; Leneena, Gudugunta; Krishna, Tejavath Sai; Divya, G

    2017-05-01

    Cavity preparations of posterior teeth have been frequently associated with decreased fracture strength of the teeth. Choosing the correct indirect restoration and the cavity design when restoring the posterior teeth i.e., premolars was difficult as it involves aesthetic, biomechanical and anatomical considerations. To evaluate the fracture resistance and failure pattern of three different cavity designs restored with monolithic zirconia. Human maxillary premolars atraumatically extracted for orthodontic reasons were chosen. A total of 40 teeth were selected and divided into four groups (n=10). Group I-Sound teeth (control with no preparation). Group II-MOD Inlay, Group III-Partial Onlay, Group IV-Complete Onlay. Restorations were fabricated with monolithic partially sintered zirconia CAD (SAGEMAX- NexxZr). All the 30 samples were cemented using Multilink Automix (Ivoclar) and subjected to fracture resistance testing using Universal Testing Machine (UTM) (Instron) with a steel ball of 3.5 mm diameter at crosshead speed of 0.5 mm/minute. Stereomicroscope was used to evaluate the modes of failure of the fractured specimen. Fracture resistance was tested using parametric one way ANOVA test, unpaired t-test and Tukey test. Fracture patterns were assessed using non-parametric Chi-square test. Group IV (Complete Onlay) presented highest fracture resistance and showed statistical significant difference. Group II (MOD Inlay) and Group III (Partial Onlay) showed significantly lower values than the Group I (Sound teeth). However, Groups I, II and III presented no significant difference from each other. Coming to the modes of failure, Group II (MOD Inlay) and Group III (Partial Onlay) presented mixed type of failures; Group IV (Complete Onlay) demonstrated 70% Type I failures. Of the three cavity designs evaluated, Complete Onlay had shown a significant increase in the fracture resistance than the Sound teeth.

  5. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study.

    PubMed

    Örtorp, Anders; Jönsson, David; Mouhsen, Alaa; Vult von Steyern, Per

    2011-04-01

    This study sought to evaluate and compare the marginal and internal fit in vitro of three-unit FDPs in Co-Cr made using four fabrication techniques, and to conclude in which area the largest misfit is present. An epoxy resin master model was produced. The impression was first made with silicone, and master and working models were then produced. A total of 32 three-unit Co-Cr FDPs were fabricated with four different production techniques: conventional lost-wax method (LW), milled wax with lost-wax method (MW), milled Co-Cr (MC), and direct laser metal sintering (DLMS). Each of the four groups consisted of eight FDPs (test groups). The FDPs were cemented on their cast and standardised-sectioned. The cement film thickness of the marginal and internal gaps was measured in a stereomicroscope, digital photos were taken at 12× magnification and then analyzed using measurement software. Statistical analyses were performed with one-way ANOVA and Tukey's test. Best fit based on the means (SDs) in μm for all measurement points was in the DLMS group 84 (60) followed by MW 117 (89), LW 133 (89) and MC 166 (135). Significant differences were present between MC and DLMS (p<0.05). The regression analyses presented differences within the parameters: production technique, tooth size, position and measurement point (p < 0.05). Best fit was found in the DLMS group followed by MW, LW and MC. In all four groups, best fit in both abutments was along the axial walls and in the deepest part of the chamfer preparation. The greatest misfit was present occlusally in all specimens. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. The influence of different placement techniques on the microtensile bond strength of low-shrink silorane composite bonded to Class I cavities.

    PubMed

    Almeida e Silva, J S; Rolla, Juliana Nunes; Baratieri, Luiz Narciso; Monteiro, Sylvio

    2011-01-01

    The aim of this in vitro study was to evaluate the microtensile bond strength (µTBS) of a low-shrink silorane-based composite (Filtek Silorane) and a methacrylate-based composite (Filtek Z250) to the bottom dentin of a Class I cavity using different placement techniques. Twelve third molars were used. Standard, box-type Class I cavities (6.0 x 4.0 x 2.5 mm) were prepared at the occlusal crown center, with the pulpal floor ending approximately at the midcoronal dentin. The teeth were then randomly divided into four groups, according to each placement technique: ZI--Filtek Z250 placed incrementally; ZB--Filtek Z250 placed in bulk; SI--Filtek Silorane placed incrementally; and SB--Filtek Silorane placed in bulk. Each restored third molar was subjected to microtensile bond testing after 24 hours of storage in distilled water at 37 degrees C. After storage, each molar was longitudinally sectioned in both axes to obtain rectangular sticks with an approximate 0.49 mm2 cross-sectional area. Data were analyzed by one-way ANOVA followed by a Tukey post hoc test (P = 0.05). After debonding, the failure modes were analyzed using a stereomicroscope. The ZI group (72.6 MPa) showed the highest µTBS, followed by the ZB group (60.2 MPa), while the SI (34.4 MPa) and SB (42.6 MPa) groups demonstrated statistically significant lower bond strengths. The type of placement technique did not influence the µTBS of silorane-based composites to the bottom dentin of Class I cavities. The methacrylate-based composite showed superior performance, regardless of the placement technique.

  7. Effects of six different preventive treatments on the shear bond strength of orthodontic brackets: in vitro study.

    PubMed

    Cossellu, Gianguido; Lanteri, Valentina; Butera, Andrea; Sarcina, Michele; Farronato, Giampietro

    2015-01-01

    Objective : The aim of this study is to evaluate the effect of six different prophylactic agents on shear bond strength (SBS) of orthodontic brackets. Materials and methods : One hundred twenty-six freshly extracted mandibular bovine incisors were used. Teeth were randomly divided into 7 equal groups (18 per group) as follows: group-1 served as control with no pre-treatment; group-2 enamel treated with fluoride varnish (Fluor Protector, Ivoclar Vivadent); group-3 containing casein-phosphopeptide-amorphous calcium-phosphate (CPP-ACP) paste (GC Tooth Mousse, RECALDENT™); group-4 with ozone (HealOzone, Kavo ) ; group-5 with glycine powder (Perio Flow, EMS); group-6 with hydroxyapatite powder 99.5% (Coswell S.p.A.); group-7 with a toothpaste made of hydroxyapatite nanocrystals (BioRepair® Plus, Coswell S.p.A). Brackets were all bonded using the same technique with transbond XT (3 M Unitek, Monrovia, CA). All the bonded specimens were stored for 24 h in deionized water (37 °C) and subjected to thermal cycling for 1000 cycles. The SBS was measured with an Instron Universal Testing machine and the adhesive remnant was assessed with the adhesive remnant index (ARI) using a stereomicroscope at 10× magnification. Results : Statistical differences (ANOVA) were found among the seven investigated groups ( F = 12.226, p < 0.001). SBS of groups 2, 5 and 6 were significantly lower than the control group ( p < 0.05). ARI scores (chi-square test) were correlated with the differences of SBS values. Conclusion: CPP-ACP paste, ozone or BioRepair® did not compromise on bracket bond strength. Fluoride, glycine or hydroxyapatite significantly decreased the SBS; only the fluoride group showed significant clinically low (<6 MPa) SBS values.

  8. Color stability and marginal integrity of interim crowns: An in vitro study

    PubMed Central

    Elagra, Marwa I.; Rayyan, Mohammad R.; Alhomaidhi, Maisam M.; Alanaziy, Areej A.; Alnefaie, Mona O.

    2017-01-01

    Objective: Many commercial dental materials are used to fabricate interim restorations. This study aimed to compare the color stability and the marginal integrity of four different interim crown materials. Materials and Methods: An ivorine right maxillary central incisor was prepared for a full coverage all-ceramic restoration. A total of 36 specimens in the form of crowns were fabricated on the master die using four different materials (n = 9); Polymethyl methacrylate (PMMA) resin (TrimPLUS), PMMA computer-aided design, and computer-aided manufacturing (CAD-CAM) blocks (Ceramill TEMP), cold cure bis-acryl resin (Success CD), and bis-acryl resin dual-cure composite (TempSpan). Color change ΔE for each sample was calculated by measuring its color as Commission Internationale de l’Eclairage L* a* b* with a spectrophotometer before and after immersing in a concentrated tea solution for 7 days. Marginal gap was measured at four reference points using stereomicroscope at ×40. One-way ANOVA and the Tukey multiple comparisons test were used to determine any statistically significant difference between the four groups, (α = 0.05). Results: Success CD showed significantly the greatest color change (7.7) among all the tested materials, while no significant difference was found between the other three materials. TempSpan showed significantly the highest marginal gap formation (430.15 μm), while no significant difference was found between the three other materials. Conclusions: Bis-acryl resin composite materials demonstrated clinically noticeable change in color while PMMA materials demonstrated superior color stability. Dual cure interim materials exhibited significantly higher marginal discrepancy in comparison to PMMA and cold cure bis-acrylic resin materials. CAD-CAM PMMA material exhibited the best color stability and marginal integrity. PMID:28932142

  9. Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks.

    PubMed

    Pasali, Baris; Sarac, Duygu; Kaleli, Necati; Sarac, Yakup Sinasi

    2018-02-01

    Recently, presintered metal blocks for nonprecious and precious metal implant-supported restorations have gained popularity in computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, few studies have evaluated the marginal discrepancy of implant-supported restorations made with these new alloy systems. The purpose of this in vitro study was to compare the milling-sintering method with the lost-wax and milling methods in terms of the marginal fit of implant-supported metal-ceramic restorations. Thirty implant abutments screwed to implant analogs were embedded into acrylic resin to investigate marginal fit and then divided according to fabrication methods into the following 3 groups (n=10): lost-wax (LW; control group), milling (M), and milling-sintering (MS). Porcelain material was applied to all specimens after completion of the fabrication process. Subsequently, all specimens were cemented to implant abutments for the measurement of marginal discrepancies. Twelve marginal discrepancy measurements were recorded on each implant abutment by using a stereomicroscope. The arithmetic mean of these 12 measurements was considered the mean marginal discrepancy value of each abutment. Data were statistically analyzed by using 1-way ANOVA and Tukey honest significant difference tests (α=.05). The lowest mean marginal discrepancy values (81 ±2 μm) were observed in the M group, which was significantly different (P<.001) from the other methods. The highest mean marginal discrepancy values (99 ±2 μm) were observed in the MS group. The results revealed that restorations prepared by the milling-sintering method provided clinically acceptable results (<120 μm); however, this new technique was not found to be as precise as the milling method in terms of marginal fit. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Effect of different aging methods on the mechanical behavior of multi-layered ceramic structures.

    PubMed

    Borba, Márcia; de Araújo, Maico D; Fukushima, Karen A; Yoshimura, Humberto N; Griggs, Jason A; Della Bona, Álvaro; Cesar, Paulo F

    2016-12-01

    To evaluate the effect of two aging methods (mechanical cycling and autoclave) on the mechanical behavior of veneer and framework ceramic specimens with different configurations (monolithic, two and three-layers). Three ceramics used as framework for fixed dental prostheses (YZ-Vita In-Ceram YZ; IZ-Vita In-Ceram Zirconia; AL-Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs: monolithic, two layers (porcelain-framework) and three layers (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. Three different experimental conditions were evaluated (n=10): control; mechanical cycling (2Hz, 37°C artificial saliva); and autoclave aging (134°C, 2 bars, 5h). Bi-layered specimens were tested in both conditions: with porcelain or framework ceramic under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy. Results were statistically analyzed using Kruskal-Wallis and Student-Newman-Keuls tests. Only for AL group, mechanical cycling and autoclave aging significantly decreased the flexural strength values in comparison to the control (p<0.01). YZ, AL, VM7 and VM9 monolithic groups showed no strength degradation. For multi-layered specimens, when the porcelain layer was tested in tension (bi and tri-layers), the aging methods evaluated also had no effect on strength (p≥0.05). Total and partial failure modes were identified. Mechanical cycling and autoclave aging protocols had no effect on the flexural strength values and failure behavior of YZ and IZ ceramic structures. Yet, AL monolithic structures showed a significant decrease in flexural strength with any of the aging methods. Copyright © 2016. Published by Elsevier Ltd.

  11. Comparative evaluation of microleakage in Class II restorations using open vs. closed centripetal build-up techniques with different lining materials

    PubMed Central

    Sawani, Shefali; Arora, Vipin; Jaiswal, Shikha; Nikhil, Vineeta

    2014-01-01

    Background: Evaluation of microleakage is important for assessing the success of new restorative materials and methods. Aim and Objectives: Comparative evaluation of microleakage in Class II restorations using open vs. closed centripetal build-up techniques with different lining materials. Materials and Methods: Standardized mesi-occlusal (MO) and distoocclusal (DO) Class II tooth preparations were preparedon 53 molars and samples were randomly divided into six experimental groups and one control group for restorations. Group 1: Open-Sandwich technique (OST) with flowable composite at the gingival seat. Group 2: OST with resin-modified glass ionomer cement (RMGIC) at the gingival seat. Group 3: Closed-Sandwich technique (CST) with flowable composite at the pulpal floor and axial wall. Group 4: CST with RMGIC at the pulpal floor and axial wall. Group 5: OST with flowable composite at the pulpal floor, axial wall, and gingival seat. Group 6: OST with RMGIC at the pulpal floor, axial wall, and gingival seat. Group 7: Control — no lining material, centripetal technique only. After restorations and thermocycling, apices were sealed and samples were immersed in 0.5% basic fuchsin dye. Sectioning was followed by stereomicroscopic evaluation. Results: Results were analyzed using Post Hoc Bonferroni test (statistics is not a form of tabulation). Cervical scores of control were more than the exprimental groups (P < 0.05). Less microleakage was observed in CST than OST in all experimental groups (P < 0.05). However, insignificant differences were observed among occlusal scores of different groups (P > 0.05). Conclusion: Class II composite restorations with centripetal build-up alone or when placed with CST reduces the cervical microleakage when compared to OST. PMID:25125847

  12. Role of TiF4 in Microleakage of Silorane and Methacrylate-based Composite Resins in Class V Cavities.

    PubMed

    Koohpeima, Fatemeh; Sharafeddin, Farahnaz; Jowkar, Zahra; Ahmadzadeh, Samaneh; Mokhtari, Mohammad Javad; Azarian, Babak

    2016-03-01

    This study investigated the effect of TiF4 solution pretreat-ment on microleakage of silorane and nanofilled methacrylate-based composites in class V cavities. Forty-eight intact premolar teeth were randomly allocated to four groups of 12 teeth. Restorative techniques after standard class V tooth preparations were as follows: Group 1, Filtek P90 composite; group 2, Filtek Z350 XT; group 3, TiF4 solution pretreatment and Filtek P90 composite; group 4, TiF4 solution pretreatment and Filtek Z350 XT. After storing the specimens in distilled water at 37°C for 24 hours and followed by immersion of the specimens in a 0.5% basic-fuchsin solution for 24 hours, they were sectioned buccolingually to obtain four surfaces for each specimen for analysis of microleakage using a stereomicroscope. Data analysis was performed using Kruskal-Wallis test to compare the four groups and the Mann-Whitney test for paired comparisons with Statistical Package for the Social Sciences (SPSS) version 17 software. At the enamel margins, microleakage score of the Filtek Z350 XT group was lower than those of the Filtek P90 with and without the application of the TiF4 (p = 0.009 and p = 0.031 respectively). At the dentin margins, groups 3 and 4 (TiF4+Filtek P90 and TiF4+Filtek z350 XT respectively) showed significantly lower microleakage than group 1 (Filtek P90). However, there was no significant difference between other groups (p > 0.05). At the enamel margins, microleakage score of the silorane-based composite was more than that of the nanofilled composite. No significant differences were observed between the other groups. At the dentin margins, for the silorane-based composite restorations, TiF4 solution pretreatment resulted in significantly lower microleakage. However, the similar result was not observed for Filtek Z350 XT. Also, no significant difference was observed between microleakage scores of Filtek P90 and Filtek Z350 XT with or without TiF4 pretreatment. In spite of better mechanical and physical properties of modern composites than earlier methacrylate-based composites, polymerization shrinkage has been remaining as one of the main shortcomings of them. Different methods, such as using new low shrinkage resin composites and different dentin pretreatments, have been suggested to overcome this problem. This study evaluated the effect of TiF4 as pretreatment on microleakage of class V tooth preparations restored with a nanocomposite and a silorane-based resin composite.

  13. Reliability of widefield nailfold capillaroscopy and video capillaroscopy in the assessment of patients with Raynaud’s phenomenon.

    PubMed

    Sekiyama, Juliana Y; Camargo, Cintia Z; Eduardo, Luís; Andrade, C; Kayser, Cristiane

    2013-11-01

    To analyze the diagnostic performance and reliability of different parameters evaluated by widefield nailfold capillaroscopy (NFC) with those obtained by video capillaroscopy in patients with Raynaud’s phenomenon (RP). Two hundred fifty-two individuals were assessed, including 101 systemic sclerosis (SSc; scleroderma) patients,61 patients with undifferentiated connective tissue disease, 37 patients with primary RP, and 53 controls. Widefield NFC was performed using a stereomicroscope under 10–25 x magnification and direct measurement of all parameters. Video capillaroscopy was performed under 200 x magnification, with the acquirement of 32 images per individual (4 fields per finger in 8 fingers). The following parameters were analyzed in 8 fingers of the hands (excluding thumbs) by both methods: number of capillaries/mm, number of enlarged and giant capillaries, microhemorrhages, and avascular score.Intra- and interobserver reliability was evaluated by performing both examinations in 20 individuals on 2 different days and by 2 long-term experienced observers. There was a significant correlation (P < 0.000) between widefield NFC and video capillaroscopy in the comparison of all parameters. Kappa values and intraclass correlation coefficient analysis showed excellent intra- and interobserver reproducibility for all parameters evaluated by widefield NFC and video capillaroscopy. Bland-Altman analysis showed high agreement of all parameters evaluated in both methods. According to receiver operating characteristic curve analysis, both methods showed a similar performance in discriminating SSc patients from controls. Widefield NFC and video capillaroscopy are reliable and accurate methods and can be used equally for assessing peripheral microangiopathy in RP and SSc patients. Nonetheless, the high reliability obtained may not be similar for less experienced examiners.

  14. [Effects of different surface treatments on the zirconia-resin cement bond strength].

    PubMed

    Liao, Y; Liu, X Q; Chen, L; Zhou, J F; Tan, J G

    2018-02-18

    To evaluate the effects of different surface treatments on the shear bond strength between zirconia and resin cement. Forty zirconia discs were randomly divided into four groups (10 discs in each group) for different surface treatments: control, no surface treatment; sandblast, applied air abrasion with aluminum oxide particles; ultraviolet (UV), the zirconia sample was placed in the UV sterilizer at the bottom of the UV lamp at 10 mm, and irradiated for 48 h; cold plasma, the discs were put in the cold plasma cabinet with the cold plasma generated from the gas of He for 30 s. Specimens of all the groups were surface treated prior to cementation with Panavia F 2.0 cement. The surface morphology and contact angle of water were measured. The shear bond strengths were tested and the failure modes were examined with a stereomicroscope. Surface morphology showed no difference between the UV/cold plasma group and the control group. Sandblasted zirconia displayed an overall heterogeneous distribution of micropores. The contact angle of the control group was 64.1°±2.0°. After sandblasting, UV irradiation and cold plasma exposure, the values significantly decreased to 48.8°±2.6°, 27.1°±3.6° and 32.0°±3.3°. The values of shear bond strength of the specimens with sandblasted (14.82±2.01) MPa were higher than those with no treatment (9.41±1.07) MPa with statistically significant difference (P<0.05). The values of shear bond strength of the specimens with UV irradiation (10.02±0.64) MPa were higher than those with no treatment (9.41±1.07) MPa, but without statistically significant difference (P>0.05). The values of cold plasma group (18.34±3.05) MPa were significantly higher than those of control group (9.41±1.07) MPa, even more than those with sandblast(14.82±2.01) MPa (P<0.05). X-ray photoelectron spectroscopy (XPS) showed increase in oxygen (O) and decrease in carbon (C) elements after UV and cold plasma treatment. The surface C/O ratio also decreased after UV and cold plasma treatment. Zirconia specimens treated with UV and cold plasma could significantly improve the hydrophilicity. The surface morphology was unaffected by the UV irradiation and cold plasma treatments. The improvements of ziconia shear bond strength were slight in UV group without statistically significant difference. Cold plasma treatment significantly improved the shear bond strength between zirconia and resin cement.

  15. Stereomicroscopic study of the human tooth caries: clinical and morphological correlations

    NASA Astrophysics Data System (ADS)

    Oancea, Roxana; Vasile, Liliana; Marchese, Cristian; Sava-Rosianu, Ruxandra

    2012-06-01

    Objectives: Stereomicroscopy allows a three-dimensional study of the images and of laterality at superior quality in comparison with other methods. Those advantages are given by the large examination fields and the wide work distances. The adding of the clinical and morphological data at the results gathered with stereomicroscopy and the stereo micrometry is useful in order to appreciate the deepness and the widening of the carious process, and the necessity to reconsider the therapeutically strategy. Materials and methods: During 2009-2011 the study material was represented by 10 surgically removed impacted third molars, and by 20 premolars extracted for orthodontic purposes, with closed and macroscopically apparently integer surfaces. 13 premolars with different degrees of carious affectation and periodontal lesions, which were surgically extracted without trauma, were also selected. The in situ measurements at the occlusal site were realized through the utilization of a fluorescent laser device - DIAGNOdent. The basic principles in stereomicroscopy stood at the base of the obliquely and circularly coaxial illumination techniques, one with optical alignment adjustment of the optical microscope and mechanical adjustment for the optimal illumination and micrometry. The Olympus Microscope SZ ×7 and an Olympus camera with 2,5 × digital zoom and a 3× optical zoom has been used to study the samples in stereomicroscopy and through polarized light it. Results: The DiagnoDent measured the following data: out of 43 apparently healthy teeth, 18 presented values between 2 and 13 (D1), 13 showed values between 14 and 24 (D2), 12 measured values over 24 (D3). After the histological examination in stereomicroscopy and in the polarized light: 25 teeth were healthy, 10 presented caries extended in dental enamel and 8 presented dentinal caries. Stereomicroscopy has allowed the morphological study, the color absorption, the appreciation of the lesions' deepness and substance loss that is very useful in grading the progression of the carious lesion. Conclusions: The stereomicroscopic study correlated with clinical and morphological data allowed to appreciate the extent of tissue involved in the carious process, but also the understanding of the enamel, dentine and cement matrix demineralization process, in proximity with the morpho-embryological markings of the human tooth structure.

  16. Detecting thermal phase transitions in corneal stroma by fluorescence micro-imaging analysis

    NASA Astrophysics Data System (ADS)

    Matteini, P.; Rossi, F.; Ratto, F.; Bruno, I.; Nesi, P.; Pini, R.

    2008-02-01

    Thermal modifications induced in corneal stroma were investigated by the use of fluorescence microscopy. Freshly extracted porcine corneas were immersed for 5 minutes in a water bath at temperatures in the 35-90°C range and stored in formalin. The samples were then sliced in 200-μm-thick transversal sections and analyzed under a stereomicroscope to assess corneal shrinkage. Fluorescence images of the thermally treated corneal samples were acquired using a slow-scan cooled CCD camera, after staining the slices with Indocyanine Green (ICG) fluorescent dye which allowed to detect fluorescence signal from the whole tissue. All measurements were performed using an inverted epifluorescence microscope equipped with a mercury lamp. The thermally-induced modifications to the corneal specimens were evaluated by studying the grey level distribution in the fluorescence images. For each acquired image, Discrete Fourier Transform (DFT) and entropy analyses were performed. The spatial distribution of DFT absolute value indicated the spatial orientation of the lamellar planes, while entropy was used to study the image texture, correlated to the stromal structural transitions. As a result, it was possible to indicate a temperature threshold value (62°C) for high thermal damage, resulting in a disorganization of the lamellar planes and in full agreement with the measured temperature for corneal shrinkage onset. Analysis of the image entropy evidenced five strong modifications in stromal architecture at temperatures of ~45°C, 53°C, 57°C, 66°C, 75°C. The proposed procedure proved to be an effective micro-imaging method capable of detecting subtle changes in corneal tissue subjected to thermal treatment.

  17. Effects of antimicrobial treatment on fiberglass-acrylic filters.

    PubMed

    Cecchini, C; Verdenelli, M C; Orpianesi, C; Dadea, G M; Cresci, A

    2004-01-01

    The aims of the present study were to: (i) analyse a group of antimicrobial agents and to select the most active against test microbial strains; (ii) test the effect of the antimicrobial treatment on air filters in order to reduce microbial colonization. Different kinds of antimicrobial agents were analysed to assess their compatibility with the production process of air filter media. The minimal inhibitory concentration for each antimicrobial agent was determined against a defined list of microbial strains, and an antimicrobial activity assay of filter prototypes was developed to determine the most active agent among the compatible antimicrobials. Then, the most active was chosen and added directly to the filter during the production process. The microbial colonization of treated and untreated filter media was assessed at different working times for different incubation times by stereomicroscope and scanning electron microscope analysis. Some of the antimicrobial agents analysed were more active against microbial test strains and compatible with the production process of the filter media. Filter sections analysis of treated filter media showed a significantly lower microbial colonization than those untreated, a reduction of species both in density and varieties and of the presence of bacteria and fungal hyphae with reproductive structures. This study demonstrated the ability of antimicrobial treatments to inhibit the growth of micro-organisms in filter media and subsequently to increase indoor air quality (IAQ), highlighting the value of adding antimicrobials to filter media. To make a contribution to solving the problem of microbial contamination of air filters, by demonstrating the efficacy of incorporating antimicrobial agents in the filter media to improve IAQ and health.

  18. Comparative analysis of gingival phenotype in animal and human experimental models using optical coherence tomography in a non-invasive approach

    NASA Astrophysics Data System (ADS)

    Mota, Cláudia C. B. O.; Fernandes, Luana O.; Melo, Luciana S. A.; Feitosa, Daniela S.; Cimões, Renata; Gomes, Anderson S. L.

    2015-06-01

    Imaging methods are widely used in diagnostic and among the diversity of modalities, optical coherence tomography (OCT) is nowadays commercially available and considered the most innovative technique used for imaging applications, in both medical and non-medical applications. In this study, we exploit the OCT technique in the oral cavity for identification and differentiation between free and attached gingiva, as well as determining the gingival phenotype, an important factor to determination of periodontal prognosis in patients. For the animal studies, five porcine jaws were analyzed using a Swept Source SS-OCT system operating at 1325nm and stereomicroscope, as gold pattern. The SSOCT at 1325nm was chosen due to the longer central wavelength, that allows to deeper penetration imaging, and the faster image acquisition, an essential factor for clinical setting. For the patient studies, a total of 30 males and female were examined using the SS-OCT at 1325nm and computer controlled periodontal probing. 2D and 3D images of tooth/gingiva interface were performed, and quantitative measurements of the gingival sulcus could be noninvasively obtained. Through the image analysis of the animals jaws, it was possible to quantify the free gingiva and the attached gingiva, the calculus deposition over teeth surface and also the subgingival calculus. For the patient's studies, we demonstrated that the gingival phenotype could be measured without the periodontal probe introduction at the gingival sulcus, confirming that OCT can be potentially useful in clinic for direct observation and quantification of gingival phenotype in a non-invasive approach.

  19. An application of stereoscopy and image processing in forensics: recovering obliterated firearms serial number

    NASA Astrophysics Data System (ADS)

    da Silva Nunes, L. C.; dos Santos, Paulo Acioly M.

    2004-10-01

    We present an application of the use of stereoscope to recovering obliterated firearms serial number. We investigate a promising new combined cheap method using both non-destructive and destructive techniques. With the use of a stereomicroscope coupled with a digital camera and a flexible cold light source, we can capture the image of the damaged area, and with continuous polishing and sometimes with the help of image processing techniques we could enhance the observed images and they can also be recorded as evidence. This method has already proven to be useful, in certain cases, in aluminum dotted pistol frames, whose serial number is printed with a laser, when etching techniques are not successful. We can also observe acid treated steel surfaces and enhance the images of recovered serial numbers, which sometimes lack of definition.

  20. Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images.

    PubMed

    Watson, Jeffrey R; Gainer, Christian F; Martirosyan, Nikolay; Skoch, Jesse; Lemole, G Michael; Anton, Rein; Romanowski, Marek

    2015-10-01

    Intraoperative applications of near-infrared (NIR) fluorescent contrast agents can be aided by instrumentation capable of merging the view of surgical field with that of NIR fluorescence. We demonstrate augmented microscopy, an intraoperative imaging technique in which bright-field (real) and electronically processed NIR fluorescence (synthetic) images are merged within the optical path of a stereomicroscope. Under luminance of 100,000 lx, representing typical illumination of the surgical field, the augmented microscope detects 189 nM concentration of indocyanine green and produces a composite of the real and synthetic images within the eyepiece of the microscope at 20 fps. Augmentation described here can be implemented as an add-on module to visualize NIR contrast agents, laser beams, or various types of electronic data within the surgical microscopes commonly used in neurosurgical, cerebrovascular, otolaryngological, and ophthalmic procedures.

  1. Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images

    NASA Astrophysics Data System (ADS)

    Watson, Jeffrey R.; Gainer, Christian F.; Martirosyan, Nikolay; Skoch, Jesse; Lemole, G. Michael, Jr.; Anton, Rein; Romanowski, Marek

    2015-10-01

    Intraoperative applications of near-infrared (NIR) fluorescent contrast agents can be aided by instrumentation capable of merging the view of surgical field with that of NIR fluorescence. We demonstrate augmented microscopy, an intraoperative imaging technique in which bright-field (real) and electronically processed NIR fluorescence (synthetic) images are merged within the optical path of a stereomicroscope. Under luminance of 100,000 lx, representing typical illumination of the surgical field, the augmented microscope detects 189 nM concentration of indocyanine green and produces a composite of the real and synthetic images within the eyepiece of the microscope at 20 fps. Augmentation described here can be implemented as an add-on module to visualize NIR contrast agents, laser beams, or various types of electronic data within the surgical microscopes commonly used in neurosurgical, cerebrovascular, otolaryngological, and ophthalmic procedures.

  2. Influences of different parameters on the microstructure of magnetic-field-induced self-assembled film

    NASA Astrophysics Data System (ADS)

    Dan, X.; Yang, J. J.

    2016-07-01

    Self-assembled films with needle-like microarrays were fabricated using a mixture of cobalt and fluorocarbon resin under a magnetic field. The various influences of magnetic powder content, viscosity and size distribution on the structure of the self-assembled films were investigated. The self-assembled film morphologies were characterized by stereomicroscope and scanning electron microscopy. Experimental results indicate that an increase in magnetic powder content results in greater unit height and diameter, and that a reduction in viscosity results in increasing array density and decreasing unit width. Additionally, particles with narrow size distribution were able to attain more regular microarray structures. The structural alterations were closely related to numerous effects such as van der Waals forces, dipole-dipole interactions, and external-dipole interactions. The self-assembled film demonstrated magnetic anisotropy, as identified by vibrating sample magnetometry (VSM).

  3. Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems

    PubMed Central

    H, Farhadpour; F, Sharafeddin; Sc, Akbarian; B, Azarian

    2016-01-01

    Statement of Problem: Hemostatic agents may affect the micro-leakage of different adhesive systems. Also, chlorhexidine has shown positive effects on micro-leakage. However, their interaction effect has not been reported yet. Objectives: To evaluate the effect of contamination with a hemostatic agent on micro-leakage of total- and self-etching adhesive systems and the effect of chlorhexidine application after the removal of the hemostatic agent. Materials and Methods: Standardized Class V cavity was prepared on each of the sixty caries free premolars at the cemento-enamel junction, with the occlusal margin located in enamel and the gingival margin in dentin. Then, the specimens were randomly divided into 6 groups (n = 10) according to hemostatic agent (H) contamination, chlorhexidine (CHX) application, and the type of adhesive systems (Adper Single Bond and Clearfil SE Bond) used. After filling the cavities with resin composite, the root apices were sealed with utility wax. Furthermore, all the surfaces, except for the restorations and 1mm from the margins, were covered with two layers of nail varnish. The teeth were immersed in a 0.5% basic fuschin dye for 24 hours, rinsed, blot-dried and sectioned longitudinally through the center of the restorations bucco- lingualy. The sections were examined using a stereomicroscope and the extension of dye penetration was analyzed according to a non-parametric scale from 0 to 3. Statistical analysis was performed using Kruskal-Wallis test and Mann-Whitney U-test. Results: While ASB group showed no micro-leakage in enamel, none of the groups showed complete elimination of micro-leakage from the dentin. Regarding micro-leakage at enamel, and dentin margins, there was no significant difference between groups 1 and 2, 1 and 3, and 2 and 3 (p > 0.05). A significantly lower micro-leakage at the enamel and dentin margins was observed in group 3, compared to group 6. No significant difference was observed between groups 4 and 5 in enamel (p = 0.35) and dentin (p = 0.34). Group 6 showed significantly higher micro-leakage, compared to group 4 and 5 (p < 0.05). Conclusions: Hemostatic agent contamination had no significant effect on micro-leakage of total- and self-etching adhesive systems. Application of chlorhexidine after the removal of hemostatic agent increased micro-leakage in self-etching adhesives but did not affect when total-etching was used. PMID:28959756

  4. Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems

    PubMed Central

    Muniz, Brenda Leite; Pires, Frederico; Belladonna, Felipe Gonçalves; Neves, Aline Almeida; Souza, Erick Miranda; De-Deus, Gustavo

    2016-01-01

    Objectives The purpose of this study was to assess the ability of ProTaper Gold (PTG, Dentsply Maillefer) in maintaining the original profile of root canal anatomy. For that, ProTaper Universal (PTU, Dentsply Maillefer) was used as reference techniques for comparison. Materials and Methods Twenty simulated curved canals manufactured in clear resin blocks were randomly assigned to 2 groups (n = 10) according to the system used for canal instrumentation: PTU and PTG groups, upto F2 files (25/0.08). Color stereomicroscopic images from each block were taken exactly at the same position before and after instrumentation. All image processing and data analysis were performed with an open source program (FIJI). Evaluation of canal transportation was obtained for two independent canal regions: straight and curved levels. Student's t test was used with a cut-off for significance set at α = 5%. Results Instrumentation systems significantly influenced canal transportation (p < 0.0001). A significant interaction between instrumentation system and root canal level (p < 0.0001) was found. PTU and PTG systems produced similar canal transportation at the straight part, while PTG system resulted in lower canal transportation than PTU system at the curved part. Canal transportation was higher at the curved canal portion (p < 0.0001). Conclusions PTG system produced overall less canal transportation in the curved portion when compared to PTU system. PMID:26877984

  5. Micro-shear bond strength of resin cement to dentin after application of desensitizing toothpastes.

    PubMed

    Bavbek, Andac Barkin; Goktas, Baris; Cekic-Nagas, Isil; Egilmez, Ferhan; Ergun, Gulfem; Eskitascioglu, Gurcan

    2013-01-01

    The aim of the study was to evaluate the effect of three desensitizing toothpastes on bonding of resin cements to dentin. The occlusal surfaces of 72 maxillary third molars were ground to obtain flat dentin surfaces and then divided into three groups according to three desensitizing toothpastes used: Sensodyne Rapid Relief (GlaxoSmithKline, SmithKline Beecham Ltd., Slough, UK), Signal Sensitive Expert (Unilever Sanayi ve Ticaret Türk A.Ş., Ümraniye, İstanbul, Turkey) and Colgate Sensitive Pro-Relief (Colgate Palmolive, New York, NY). Following bonding of the resin cement (Clearfil™ SA Cement, Kuraray Co, Osaka, Japan) to dentin, the specimens were light cured for 40 s with a LED (Elipar S10, 3M Espe, St. Paul, MN). The strength measurements were accomplished with a micro-shear testing machine (Bisco, Schaumburg, IL) at a cross-head speed of 0.5 mm/min until the failure occurs. Failure modes were examined using a stereomicroscope and scanning electron microscope. The data were analyzed with one-way analysis of variance (ANOVA) and Tukey HSD test (α = 0.05). ANOVA revealed that the application of desensitizing toothpastes had significant effects on bond strength of the resin cement tested to dentin (p < 0.05). Mixed failures were observed in all of the groups. The use of a desensitizing toothpaste before cementation might alter the bond strength of adhesively luted restorations.

  6. Comparative evaluation of tensile bond strength and microleakage of conventional glass ionomer cement, resin modified glass ionomer cement and compomer: An in vitro study.

    PubMed

    Rekha, C Vishnu; Varma, Balagopal; Jayanthi

    2012-07-01

    The purpose of this study was to evaluate and compare the tensile bond strength and microleakage of Fuji IX GP, Fuji II LC, and compoglass and to compare bond strength with degree of microleakage exhibited by the same materials. Occlusal surfaces of 96 noncarious primary teeth were ground perpendicular to long axis of the tooth. Preparations were distributed into three groups consisting of Fuji IX GP, Fuji II LC and Compoglass. Specimens were tested for tensile bond strength by mounting them on Instron Universal Testing Machine. Ninety-six primary molars were treated with Fuji IX GP, Fuji II LC, and compoglass on box-only prepared proximal surface. Samples were thermocycled, stained with dye, sectioned, and scored for microleakage under stereomicroscope. ANOVA and Bonferrani correction test were done for comparisons. Pearson Chi-square test and regression analysis were done to assess the association between the parameters. Compoglass showed highest tensile strength and Fuji II LC showed least microleakage. There was a significant difference between the three groups in tensile strength and microleakage levels. The correlation between tensile strength and microleakage level in each group showed that there was a significant negative correlation only in Group 3. Fuji II LC and compoglass can be advocated in primary teeth because of their superior physical properties when compared with Fuji IX GP.

  7. Laser radiation bracket debonding

    NASA Astrophysics Data System (ADS)

    Dostálová, Tat'jana; Jelínková, Helena; Šulc, Jan; Koranda, Petr; Nemec, Michal; Racek, Jaroslav; Miyagi, Mitsunobu

    2008-02-01

    Ceramic brackets are an aesthetic substitute for conventional stainless steel brackets in orthodontic patients. However, ceramic brackets are more brittle and have higher bond strengths, which can lead to bracket breakage and enamel damage during classical type of debonding. This study examined the possibility of laser radiation ceramic brackets removing as well as the possible damage of a surface structure of hard dental tissue after this procedure. Two types of lasers were used for the experiments - a laser diode LIMO HLU20F400 generating a wavelength of 808 nm with the maximum output power 20W at the end of the fiber (core diameter 400 μm, numerical aperture 0.22). As a second source, a diode-pumped Tm:YAP laser system generating a wavelength of 1.9 μm, with up to 3.8 W maximum output power was chosen. For the investigation, extracted incisors with ceramic brackets were used. In both cases, laser radiation was applied for 0.5 minute at a maximum power of 1 W. Temperature changes of the irradiated tissue was registered by camera Electrophysics PV320. After the interaction experiment, the photo-documentation was prepared by the stereomicroscope Nikon SMZ 2T, Japan. The surface tissue analysis was processed in "low vacuum" (30 Pa) regime without desiccation. This technique was used to record back-scattered electron images. Selecting the appropriate laser, resin, and bracket combination can minimize risks of enamel degradation and make debonding more safe.

  8. Mineralogical and chemical assessment of concrete damaged by the oxidation of sulfide-bearing aggregates: Importance of thaumasite formation on reaction mechanisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodrigues, A.; Duchesne, J., E-mail: josee.duchesne@ggl.ulaval.ca; Fournier, B.

    Damages in concrete containing sulfide-bearing aggregates were recently observed in the Trois-Rivieres area (Quebec, Canada), characterized by rapid deterioration within 3 to 5 years after construction. A petrographic examination of concrete core samples was carried out using a combination of tools including: stereomicroscopic evaluation, polarized light microscopy, scanning electron microscopy, X-ray diffraction and electron microprobe analysis. The aggregate used to produce concrete was an intrusive igneous rock with different metamorphism degrees and various proportions of sulfide minerals. In the rock, sulfide minerals were often surrounded by a thin layer of carbonate minerals (siderite). Secondary reaction products observed in the damagedmore » concrete include 'rust' mineral forms (e.g. ferric oxyhydroxides such as goethite, limonite (FeO (OH) nH{sub 2}O) and ferrihydrite), gypsum, ettringite and thaumasite. In the presence of water and oxygen, pyrrhotite oxidizes to form iron oxyhydroxides and sulphuric acid. The acid then reacts with the phases of the cement paste/aggregate and provokes the formation of sulfate minerals. Understanding both mechanisms, oxidation and internal sulfate attack, is important to be able to duplicate the damaging reaction in laboratory conditions, thus allowing the development of a performance test for evaluating the potential for deleterious expansion in concrete associated with sulfide-bearing aggregates.« less

  9. Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study

    PubMed Central

    Pompa, Giorgio; Di Carlo, Stefano; De Angelis, Francesca; Cristalli, Maria Paola; Annibali, Susanna

    2015-01-01

    This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n = 20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P < 0.05) were observed between group 3 and the other groups. The marginal opening was smallest with Co-Cr alloy substructures, while the shoulder opening was smallest with Ni-Cr alloy substructures. Within the limitations of this study, the marginal fit of an FDP is better with rapid prototyping (RP) via SLM than conventional manufacturing systems. PMID:26576419

  10. Comparison of microleakage in Class II cavities restored with silorane-based and methacrylate-based composite resins using different restorative techniques over time.

    PubMed

    Khosravi, Kazem; Mousavinasab, Seyed-Mostafa; Samani, Mahsa Sahraneshin

    2015-01-01

    Despite the growing tendency toward tooth-colored restorations in dentistry, polymerization shrinkage and subsequent marginal microleakage remains a problem. The aim of this in vitro study was to compare microleakage between silorane-based and methacrylate-based composite resins at different time intervals and with different restorative techniques. In this in vitro study, 108 sound extracted human molar teeth were used. Mesial and distal proximal class II boxes with dimensions of 1.5 mm depth and 4 mm width were prepared. The gingival margins of all cavities were 1 mm below the cement enamel junction. The teeth were randomly divided into three groups based on test materials. In the first group, the teeth were restored by a nanocomposite (Filtek Z350XT, 3MESPE) and SE Bond adhesive (Kuraray, Japan), in the second group, the teeth were restored with a silorane-based (Filtek P90, 3MESPE) and Filtek P90 Adhesive (3M ESPE, USA) and in the third group, the teeth were restored with a microhybrid posterior composite resin (Filtek P60, 3MESPE) and SE Bond adhesive (Kuraray, Japan). Half of the proximal cavities in each of these three groups were restored in two horizontal layers and the other half in four horizontal layers. After a period of aging (24-h, 3-month and 6-month) in water and then application of 500 thermal cycles, the teeth were immersed for 24-h in 0.5% fuchsin and evaluated under a stereomicroscope at ×36 magnification to evaluate leakage in gingival margin. Data was statistically analyzed using Kruskal-Wallis and Mann-Whitney U-tests. P ≤ 0.05 was considered as significant. In Z350XT statistically significant differences were observed in microleakage in comparison of 24-h and 6-month intervals (P = 0.01) that was higher in 6-month. Comparison of microleakage in P90 and P60 composite resins was also statistically significant and was less in P90. Microleakage was not significantly different between P90 and Z350XT at 24-h. However, this difference was significant at 3-month and 6-month intervals. Differences in microleakage of P60 and Z-350XT composite resins were not statistically significant in all intervals (P = 0.38). P90 showed the lowest microleakage during storage in water. Z350XT had microleakage similar to P90 within 24-h, but after 6-month of storage in water, it showed the highest microleakage among all the groups. The number of layers (2 layers vs. 4 layers) did not result in any differences in microleakage scores of the composite resins (P = 0.42). Water storage times did not result in any significant effect on microleakage of P90 and P60.

  11. Microleakage and shear punch bond strength in class II primary molars cavities restored with low shrink silorane based versus methacrylate based composite using three different techniques.

    PubMed

    Fahmy, Amal Ezzeldin; Farrag, Nadia Moustafa

    2010-01-01

    This in vitro study aimed to evaluate the gingival microleakage in class II cavities in primary molars restored with a low shrink silorane resin composite (Filtek P90) or a nanohybride composite resin (Filtek supreme XT) using three different techniques, (total bonding, closed or open sandwich techniques) lined by nano-filled resin modified glass ionomer cement RMGIC (Ketac N100). Additionally, the shear punch bond strength between the two types of composite and KNIO0 was also examined. For microleakage test, two standardized class II slot cavities were prepared in proximal surfaces of 60 sound extracted primary molars which were divided into 2 groups of 30 each according to the type of composite. Each group was subdivided into 3 groups (n = 10) according to the restorative technique used. The restored teeth were examined for microleakage after immersion in 2% methylene blue dye using stereomicroscope at 20 X. Microleakage scores among the groups were compared using Kruskal Wallis test followed by pair wise Mann Whitney U test at P < or = 0.05. Thirty disc specimens were prepared for determining the shear punch bond strength between the two composite materials and the KN100. Specimens were divided into 5 groups (n = 6) according to the adhesive protocol. The differences in mean bond strength values in MPa between groups were statistically analyzed using ANOVA followed by pair wise Tukey Post hoc test at P < or = 0. 05. Mode of failure was also evaluated for all groups. Both the silorane resin and nano-composite resin showed superior marginal seal with the total bonding technique compared to closed and open sandwich techniques. The recorded mean shear punch bond strength values showed no statistical significant difference between the two resin composites without or with their adhesive bonding systems when bonded to the nano-ionomer. All specimens showed cohesive mode of failures except for silorane resin with Adper Easy Bond Self Etch Adhesive (AEBSEA) which showed adhesive mode of failure. The best marginal seal was obtained with the total bonding technique using both resin composites. The shear punch bond strength between KN100 and the two composite materials was not affected by either of the used adhesive bonding agent.

  12. First record of Tuxophorus caligodes (Siphonostomatoida, Tuxophoridae) in sea-farmed cobia, Rachycentron canadum, in Brazil.

    PubMed

    da Silva, Ana Carolina; de Moraes, Julieta Rodini Engrácia; Antonucci, Antonio Mataresio; Shimada, Marina Tie; Takemoto, Ricardo Massato; Engrácia Filho, Jair Rodini; de Moraes, Flávio Ruas

    2012-01-01

    The cobia is the only representative of the Rachycentridae family and, because of its zootechnical qualities, production of this fish has been implemented in several countries, such as the United States, Mexico and Brazil. Tuxophorus caligodes is a widespread parasite of marine fish worldwide. For the present report, 15 juvenile cobias were collected from net cages on a fish farm in Ilhabela, state of São Paulo, Brazil, in the winter of 2011. The fish were sacrificed by means of cerebral concussion, and then weighed (280 ± 70.5 g) and measured (27 ± 1.97 cm). After external examination under a stereomicroscope, ectoparasites present on the body surface were collected, fixed and processed for identification. Out of the 15 fish examined, two were parasitized with Tuxophorus caligodes, thus indicating a prevalence of 13.3%. This is the first report of Tuxophorus caligodes in cobias in Brazil.

  13. Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images

    PubMed Central

    Watson, Jeffrey R.; Gainer, Christian F.; Martirosyan, Nikolay; Skoch, Jesse; Lemole, G. Michael; Anton, Rein; Romanowski, Marek

    2015-01-01

    Abstract. Intraoperative applications of near-infrared (NIR) fluorescent contrast agents can be aided by instrumentation capable of merging the view of surgical field with that of NIR fluorescence. We demonstrate augmented microscopy, an intraoperative imaging technique in which bright-field (real) and electronically processed NIR fluorescence (synthetic) images are merged within the optical path of a stereomicroscope. Under luminance of 100,000 lx, representing typical illumination of the surgical field, the augmented microscope detects 189 nM concentration of indocyanine green and produces a composite of the real and synthetic images within the eyepiece of the microscope at 20 fps. Augmentation described here can be implemented as an add-on module to visualize NIR contrast agents, laser beams, or various types of electronic data within the surgical microscopes commonly used in neurosurgical, cerebrovascular, otolaryngological, and ophthalmic procedures. PMID:26440760

  14. Evaluation of the antimicrobial activity of three irrigating solutions in teeth with pulpal necrosis.

    PubMed

    Ferreira, C M; Bonifácio, K C; Fröner, I C; Ito, I Y

    1999-01-01

    The antimicrobial activity of 0.4% papaine gel (FCF-USP), an antibacterial product derived from 3.3% castor oil (IQSC-USP), and 0.5% sodium hypochlorite (FORP-USP) was evaluated in teeth with radiographically visible pulpal necrosis and periapical lesion in vivo. After cavity access, under aseptic conditions, a first harvesting was performed. The 3 irrigating solutions were used for biomechanical preparation. After 72 hours, a second harvesting was performed, also under aseptic conditions. The number of colony forming units (cfu) was counted with a stereomicroscope under reflected light. Castor oil and 0.5% sodium hypochlorite presented similar antimicrobial activities for the reduction of the anaerobe number, S. mutans and streptococci; however, the papaine gel showed lower activity. We conclude that both castor oil and sodium hypochlorite are effective as antimicrobial agents and can be used in the treatment of root canals with pulpal necrosis.

  15. iQOS: evidence of pyrolysis and release of a toxicant from plastic.

    PubMed

    Davis, Barbara; Williams, Monique; Talbot, Prue

    2018-03-13

    To evaluate performance of the I quit original smoking (iQOS) heat-not-burn system as a function of cleaning and puffing topography, investigate the validity of manufacturer's claims that this device does not burn tobacco and determine if the polymer-film filter is potentially harmful. iQOS performance was evaluated using five running conditions incorporating two different cleaning protocols. Heatsticks were visually and stereomicroscopically inspected preuse and postuse to determine the extent of tobacco plug charring (from pyrolysis) and polymer-film filter melting, and to elucidate the effects of cleaning on charring. Gas chromatography-mass spectrometry headspace analysis was conducted on unused polymer-film filters to determine if potentially toxic chemicals are emitted from the filter during heating. For all testing protocols, pressure drop decreased as puff number increased. Changes in testing protocols did not affect aerosol density. Charring due to pyrolysis (a form of organic matter thermochemical decomposition) was observed in the tobacco plug after use. When the manufacturer's cleaning instructions were followed, both charring of the tobacco plug and melting of the polymer-film filter increased. Headspace analysis of the polymer-film filter revealed the release of formaldehyde cyanohydrin at 90°C, which is well below the maximum temperature reached during normal usage. Device usage limitations may contribute to decreases in interpuff intervals, potentially increasing user's intake of nicotine and other harmful chemicals. This study found that the tobacco plug does char and that charring increases when the device is not cleaned between heatsticks. Release of formaldehyde cyanohydrin is a concern as it is highly toxic at very low concentrations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Fractographic analysis of 2.0-mm plates with a screw locking system in simulated fractures of the mandibular body.

    PubMed

    de Medeiros, Raquel Correia; Lauria de Moura, Andrezza; Rodrigues, Danillo Costa; Menezes Mendes, Marcelo Breno; Sawazaki, Renato; Fernandes Moreira, Roger William

    2014-06-01

    The purpose of the present study was to analyze the fractured plates from 2 brands of 2.0-mm locking fixation systems submitted to axial linear load testing. Four aluminum hemimandibles with linear sectioning to simulate a mandibular body fracture were used as a substrate and fixed with 2 fixation techniques from 2 national brands: Tóride and Traumec. The techniques were as follows: one 4-hole plate, with four 6-mm screws in the tension zone, and one 4-hole plate, with four 10-mm screws in the compression zone; and one 4-hole plate, with four 6-mm holes in the neutral zone. The hemimandibles were submitted to vertical linear load tests using an Instron 4411 mechanical test machine. The system was submitted to the test until complete failure had occurred. Next, a topographic analysis of the surface of the plates was performed using a stereomicroscope and an electronic scanning microscope. The samples were evaluated using different magnifications, and images were obtained. The surface of the fracture analyzed in scanning electron microscopy demonstrated a ductile-type fracture, usually found in the traction test bodies of ductile materials, such as titanium. No evidence of failure was observed in any fracture surface from a change in the structure or composition of the material. The plates were fractured by a ductile rupture mechanism, as expected, suggesting that the manufacturing of the national brand name plates used in the present study has been under adequate quality control, with no structural changes produced by the manufacturing process that could compromise their function. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Evaluation and comparison of the marginal adaptation of two different substructure materials.

    PubMed

    Karaman, Tahir; Ulku, Sabiha Zelal; Zengingul, Ali Ihsan; Guven, Sedat; Eratilla, Veysel; Sumer, Ebru

    2015-06-01

    In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, 24.47 ± 5.82 µm before and 35.11 ± 6.52 µm after cementation; in the laser-sintered Co-Cr structure, it was, on average, 60.45 ± 8.87 µm before and 69.33 ± 9.03 µm after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.

  18. Evaluation and comparison of the marginal adaptation of two different substructure materials

    PubMed Central

    Karaman, Tahir; Ulku, Sabiha Zelal; Zengingul, Ali Ihsan; Eratilla, Veysel; Sumer, Ebru

    2015-01-01

    PURPOSE In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. RESULTS According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, 24.47 ± 5.82 µm before and 35.11 ± 6.52 µm after cementation; in the laser-sintered Co-Cr structure, it was, on average, 60.45 ± 8.87 µm before and 69.33 ± 9.03 µm after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings. PMID:26140178

  19. Development of computer-assisted instruction application for statistical data analysis android platform as learning resource

    NASA Astrophysics Data System (ADS)

    Hendikawati, P.; Arifudin, R.; Zahid, M. Z.

    2018-03-01

    This study aims to design an android Statistics Data Analysis application that can be accessed through mobile devices to making it easier for users to access. The Statistics Data Analysis application includes various topics of basic statistical along with a parametric statistics data analysis application. The output of this application system is parametric statistics data analysis that can be used for students, lecturers, and users who need the results of statistical calculations quickly and easily understood. Android application development is created using Java programming language. The server programming language uses PHP with the Code Igniter framework, and the database used MySQL. The system development methodology used is the Waterfall methodology with the stages of analysis, design, coding, testing, and implementation and system maintenance. This statistical data analysis application is expected to support statistical lecturing activities and make students easier to understand the statistical analysis of mobile devices.

  20. Descriptive data analysis.

    PubMed

    Thompson, Cheryl Bagley

    2009-01-01

    This 13th article of the Basics of Research series is first in a short series on statistical analysis. These articles will discuss creating your statistical analysis plan, levels of measurement, descriptive statistics, probability theory, inferential statistics, and general considerations for interpretation of the results of a statistical analysis.

  1. Evaluating the Microshear Bond Strength and Microleakage of Flowable Composites Containing Zinc Oxide Nano-particles.

    PubMed

    Teymoornezhad, Koorosh; Alaghehmand, Homayoun; Daryakenari, Ghazaleh; Khafri, Soraya; Tabari, Mitra

    2016-11-01

    Preventive resin restorations (PRR) are the conservative choice for the most common carious lesions in children. Thus, new age flowable resin composites with higher filler content are readily used. The aim of this study was to evaluate the microshear bond strength and microleakage of two flowable resin composites containing different percentages of nano zinc oxide (NZnO) particles, which have proven to have antimicrobial properties. This experimental in-vitro study was carried out in the Dental Material Research Center of Babol University of Medical Sciences in 2015. One nanohybrid and one nanofill flowable resin composite were chosen and modified with the incorporation of 1% and 3% Wt NZnO particles. Six groups (n=10, 0%, 1%, and 3%) of resin composite sticks on dental enamel (2×2mm) were prepared to be placed in the microtensile tester. The microshear bond strength magnitude (MPa) was recorded at the point of failure. A class I box (3×0.8×1 mm) was prepared on 60 premolars and filled using the resin composites (6 groups, n=10). The specimens were immersed in a 5% basic fuschin solution and sectioned bucco-lingually to view the microleakage using a stereomicroscope. One-way ANOVA and Tukey tests for microshear and Wilcoxon and Kruskal-Wallis tests for microleakage were used to analyze the data in the IBM SPSS Statistics version 22 software. The bond strength of the 3% clearfill group significantly decreased while no significant change occurred in the bond strength in other groups. The Z-350 group had significantly lower microleakage as nanoparticles increased. No significant difference was observed in the clearfill group. Up to 3% Wt incorporation of NZnO particles will not diversely alter the bond strength, but it will be beneficial in providing antimicrobial effects with lower microleakage rates.

  2. Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns.

    PubMed

    Alghazzawi, Tariq F; Al-Samadani, Khalid H; Lemons, Jack; Liu, Perng-Ru; Essig, Milton E; Bartolucci, Alfred A; Janowski, Gregg M

    2015-02-01

    To compare the marginal gap using different types of die stones and titanium dies with and without powders for imaging. A melamine tooth was prepared and scanned using a laboratory 3-shape scanner to mill a polyurethane die, which was duplicated into different stones (Jade, Lean, CEREC) and titanium. Each die was sprayed with imaging powders (NP, IPS, Optispray, Vita) to form 15 groups. Ten of each combination of stone/titanium and imaging powders were used to mill crowns. A light-bodied impression material was injected into the intaglio surface of each crown and placed on the corresponding die. Each crown was removed, and the monophase material was injected to form a monophase die, which was cut into 8 sections. Digital images were captured using a stereomicroscope to measure marginal gap. Scanning electron microscopy was used to determine the particle size and shape of imaging powders and stones. Marginal gaps ranged from mean (standard deviation) 49.32 to 1.20 micrometers (3.97-42.41 μm). There was no statistical difference (P > .05) in the marginal gap by any combination of stone/titanium and imaging powders. All of the imaging powders had a similar size and rounded shape, whereas the surface of the stones showed different structures. When a laboratory 3-shape scanner is used, all imaging powders performed the same for scanning titanium abutments. However, there was no added value related to the use of imaging powder on die stone. It is recommended that the selection of stone for a master cast be based on the hysical properties. When a laboratory 3-shape scanner is used, the imaging powder is not required for scanning die stone. Whenever scanning titanium implant abutments, select the least expensive imaging powder. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  3. Factors affecting marginal integrity of class II bulk-fill composite resin restorations

    PubMed Central

    Savadi Oskoee, Siavash; Bahari, Mahmoud; Jafari Navimipour, Elmira; Ajami, Amir Ahmad; Ghiasvand, Negar; Savadi Oskoee, Ayda

    2017-01-01

    Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, one on the mesial aspect 1 mm coronal to the CEJ and one on the distal aspect 1 mm apical to the CEJ. The teeth were divided into 4 groups: A: The cavities were restored using the bulk-fill technique with Filtek P90 composite resin and its adhesive system and light-cured with quartz tungsten halogen (QTH) light-curing unit. B: The cavities were restored similar to that in group A but light-cured with an LED light-curing unit. C: The cavities were restored using the bulk-fill technique with X-tra Fil composite resin and Clearfil SE Bond adhesive system and light-cured with a QTH curing unit. D: The cavities were restored similar to that in group C but light-cured with an LED light-curing unit. The gaps were examined under a stereomicroscope at ×60. Data were analyzed with General Linear Model test. In cases of statistical significance (P<0.05), post hoc Bonferroni test was used for further analyses. Results. The light-curing unit type had no effect on gap formation. However, the results were significant in relation to the composite resin type and margin location (P<0.001). The cumulative effects of light-curing unit*gingival margin and light-curing unit*composite resin type were not significant; however, the cumulative effect of composite rein type*gingival margin was significant (P=0.04) Conclusion. X-tra Fil composite exhibited smaller gaps compared with Filtek P90 composite with both light-curing units. Both composite resins exhibited smaller gaps at enamel margins. PMID:28748051

  4. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.

    PubMed

    Kim, Seok-Gyu; Park, Jae-Uk; Jeong, Jae-Heon; Bae, Chang; Bae, Tae-Soo; Chee, Winston

    2009-01-01

    The purpose of this study was to evaluate the clinical efficacy of implant prostheses retained by screws and cement (SCPs) by examining the reverse torque values (RTVs) of the abutment screws and the marginal openings of the implant prostheses. Two implants (3.8 x 13 mm; Camlog Biotechnologies) were embedded in an acrylic resin block 5 mm apart. Eighteen copies of this resin specimen were fabricated and randomly divided into two groups. Two-unit implant prostheses with two different designs-purely cement-retained implant prostheses (group 1) and SCPs (group 2)-were made out of type IV gold alloy and placed on the implants. After tightening to about 30 Ncm, the preloading RTVs of the abutment screws were measured. After retightening the abutment screws or cementing the prostheses, followed by cyclic loading, the postloading RTVs of the abutment screws were examined. Also, the marginal openings of the prostheses in the two groups were measured under a stereomicroscope. These measurements were compared statistically. The postloading RTVs and their differences from the preloading RTVs of the abutment screws demonstrated no significant differences between groups (P > .05). Group 2 prostheses showed significantly smaller marginal openings than group 1 prostheses (P < .05). The forces generated when torquing the abutment screw of the SCP did not cause more loosening of the abutment screws than the purely cement-retained implant prosthesis. The SCP showed better marginal adaptation of the cement-retained part than the purely cement-retained implant prosthesis, possibly as a result of the screw-retained abutment seating the restoration. Within the limitations of this in vitro test, the SCP showed no significant difference in RTV of the abutment screw and a smaller marginal gap compared to a purely cement-retained implant prosthesis.

  5. [Influence of carbodiimide-ethanol solution surface treatment on dentin microtensile bond strength].

    PubMed

    Zhang, Yi; Liu, Yu-hua; Zhou, Yong-sheng; Chung, Kwok-hung

    2015-10-18

    To evaluate the microtensile bond strength changes and patterns of fractures of the bonding interface after dentine surface treatment with carbodiimide-ethanol solution. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) dissolved in ethanol was diluted into different concentrations of 2, 1, 0.3, 0.1 and 0.01 mol/L EDC-ethanol solutions. Twenty-eight caries-free extracted human third molars were ground metallurgically to prepare flat occlusal mid-coronal dentin surfaces and etched with 35% (mass fraction) phosphoric acid gel. Then they were treated with EDC-ethanol solution for 60 s before the bonding procedure and randomly divided into five experimental groups corresponding to the tested EDC-ethanol concentrations. The ethanol treated and no pre-treated surfaces were used as controls. Single Bond 2 adhesive was applied and resin composite disk was stacked on the treated dentine surface. The teeth with resin composite disks were stored in water at room temperature for 24 h and then sectioned longitudinally to produce stick specimens for microtensile bond strength test. Fracture patterns were observed with a stereomicroscope. The dentin surfaces pre-treated with 2 mol/L [(22.17±13.31) MPa] and 1 mol/L [(45.31±17.80) MPa] EDC-ethanol solutions resulted in statistically significant lower bond strength value (P<0.05). Increasing numbers of fracture pattern at the resin-dentin interface were also found in this two groups with percentages of 81.2% and 41.3% respectively. No significant difference was observed in the groups with 0.3, 0.1, 0.01 mol/L EDC surface treatment (P>0.05). No significant difference of immediate bond strengths was found in the 0.3, 0.1, 0.01 mol/L groups compared with the control group. EDC-ethanol solution surface treatment with concentrations of 2 mol/L and 1 mol/L resulted in decreasing of the bonding strength.

  6. Microleakage of Posterior Composite Restorations with Fiber Inserts Using two Adhesives after ging

    PubMed Central

    Sharafeddin, F; Yousefi, H; Modiri, Sh; Tondari, A; Safaee Jahromi, SR

    2013-01-01

    Statement of Problem: Microleakage is one of the most frequent problems associated with resin composites, especially at the gingival margin of posterior restorations. Insertion of fibers in composite restorations can reduce the total amount of composite and help to decrease the shrinkage. Purpose: The aim of this study was to evaluate the effect of polyethylene fiber inserts on gingival microleakage of class II composite restorations using two different adhesive systems. Materials and Method: In this experimental study, class II cavities were prepared on 60 premolars. The gingival floor was located 1.0 mm below the CEJ. Dimension of each cavity were 3 mm buccolingually and 1.5 mm in axial depth. The specimens were divided into 4 groups according to the adhesive type and fiber insert (n=4). Single bond and Clearfill SE bond and Filtek p60 were used to restore the cavities. In groups without fiber inserts composite was adapted onto cavities using layering technique. For cavities with fiber inserts, 3 mm piece of fiber insert was placed onto the composite increment and cured. The specimens were stored in distilled water at 37oC for 6 months. All specimens were subjected to 3000 thermo-cycling. The tooth surfaces except for 1 mm around the restoration margins covered with two layers of nail varnish .The teeth were immersed in 2% Basic Fuchsin for 24 hours, then rinsed and sectioned mesiodistally. The microleakage was determined under a stereomicroscope (40X). Data were statistically analyzed by Kruskal-wallis and Mann-Whitney U tests (p< 0.05). Results: The Kruskal-Wallis test revealed no significant differences in mean microleakage scores among all groups (p= 0.281). Conclusion: Use of polyethylene fiber inserts and etch-and-rinse and self-etch adhesives had no effect on microleakage in class II resin composite restorations with gingival margins below the CEJ after 6- month water storage. PMID:24724129

  7. Effects of setting under air pressure on the number of surface pores and irregularities of dental investment materials.

    PubMed

    Tourah, Anita; Moshaverinia, Alireza; Chee, Winston W

    2014-02-01

    Surface roughness and irregularities are important properties of dental investment materials that can affect the fit of a restoration. Whether setting under air pressure affects the surface irregularities of gypsum-bonded and phosphate-bonded investment materials is unknown. The purpose of this study was to investigate the effect of air pressure on the pore size and surface irregularities of investment materials immediately after pouring. Three dental investments, 1 gypsum-bonded investment and 2 phosphate-bonded investments, were investigated. They were vacuum mixed according to the manufacturers' recommendations, then poured into a ringless casting system. The prepared specimens were divided into 2 groups: 1 bench setting and the other placed in a pressure pot at 172 kPa. After 45 minutes of setting, the rings were removed and the investments were cut at a right angle to the long axis with a diamond disk. The surfaces of the investments were steam cleaned, dried with an air spray, and observed with a stereomicroscope. A profilometer was used to evaluate the surface roughness (μm) of the castings. The number of surface pores was counted for 8 specimens from each group and the means and standard deviations were reported. Two-way ANOVA was used to compare the data. Specimens that set under atmospheric air pressure had a significantly higher number of pores than specimens that set under increased pressure (P<.05). No statistically significant differences for surface roughness were found (P=.078). Also, no significant difference was observed among the 3 different types of materials tested (P>.05). Specimens set under positive pressure in a pressure chamber presented fewer surface bubbles than specimens set under atmospheric pressure. Positive pressure is effective and, therefore, is recommended for both gypsum-bonded and phosphate-bonded investment materials. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  8. Thrips species (Insecta: Thysanoptera) associated with flowers in a restinga fragment in northeastern Brazil.

    PubMed

    Lima, I M B; Almeida-Filho, M A; Lima, M G A; Bonilla, O H; Lima, E F B

    2018-03-22

    With the growing volume of research involving Thysanoptera in Brazil, studies were carried out to improve our understanding of the diversity of thrips in areas where the fauna has historically been neglected. Accordingly, we recorded the diversity of thrips (Insecta: Thysanoptera) associated with a restinga fragment located on the campus of the State University of Ceará (UECE), Fortaleza, Ceará state, and computed the estimated richness and diversity indices. Samples were collected from 2011 through 2013 from flowers of 86 plant species. The material was taken to the Laboratory of Insect-Plant Interaction, where thrips were screened under stereomicroscope. We collected 456 adults and 58 immatures, representing 14 species, in addition to one unidentified species of Treherniella. Microcephalothrips abdominalis was found on a large number of host plants, and Frankliniella insularis was the most common species. About two-thirds of the total richness of thrips species was associated with three plant families (Amaranthaceae, Caesalpiniaceae and Poaceae); six thrips species were each associated with only one plant species. The richness of the species collected was close to that estimated by Bootstrap and Jackknife 1 analysis. The Shannon-Wiener (H') and Simpson (D) diversity indexes were 1,7607 and 0.7769, respectively. Although the species are common, 46 new associations between plant species and thrips were established, 13 of which are true host associations, which demonstrates the importance of coastal vegetation in maintaining populations of thrips.

  9. Statistical principle and methodology in the NISAN system.

    PubMed Central

    Asano, C

    1979-01-01

    The NISAN system is a new interactive statistical analysis program package constructed by an organization of Japanese statisticans. The package is widely available for both statistical situations, confirmatory analysis and exploratory analysis, and is planned to obtain statistical wisdom and to choose optimal process of statistical analysis for senior statisticians. PMID:540594

  10. Statistical Analysis of Research Data | Center for Cancer Research

    Cancer.gov

    Recent advances in cancer biology have resulted in the need for increased statistical analysis of research data. The Statistical Analysis of Research Data (SARD) course will be held on April 5-6, 2018 from 9 a.m.-5 p.m. at the National Institutes of Health's Natcher Conference Center, Balcony C on the Bethesda Campus. SARD is designed to provide an overview on the general principles of statistical analysis of research data.  The first day will feature univariate data analysis, including descriptive statistics, probability distributions, one- and two-sample inferential statistics.

  11. Study designs, use of statistical tests, and statistical analysis software choice in 2015: Results from two Pakistani monthly Medline indexed journals.

    PubMed

    Shaikh, Masood Ali

    2017-09-01

    Assessment of research articles in terms of study designs used, statistical tests applied and the use of statistical analysis programmes help determine research activity profile and trends in the country. In this descriptive study, all original articles published by Journal of Pakistan Medical Association (JPMA) and Journal of the College of Physicians and Surgeons Pakistan (JCPSP), in the year 2015 were reviewed in terms of study designs used, application of statistical tests, and the use of statistical analysis programmes. JPMA and JCPSP published 192 and 128 original articles, respectively, in the year 2015. Results of this study indicate that cross-sectional study design, bivariate inferential statistical analysis entailing comparison between two variables/groups, and use of statistical software programme SPSS to be the most common study design, inferential statistical analysis, and statistical analysis software programmes, respectively. These results echo previously published assessment of these two journals for the year 2014.

  12. Comparison of Self-Etch Primers with Conventional Acid Etching System on Orthodontic Brackets

    PubMed Central

    Zope, Amit; Zope-Khalekar, Yogita; Chitko, Shrikant S.; Kerudi, Veerendra V.; Patil, Harshal Ashok; Jaltare, Pratik; Dolas, Siddhesh G

    2016-01-01

    Introduction The self-etching primer system consists of etchant and primer dispersed in a single unit. The etching and priming are merged as a single step leading to fewer stages in bonding procedure and reduction in the number of steps that also reduces the chance of introduction of error, resulting in saving time for the clinician. It also results in smaller extent of enamel decalcification. Aim To compare the Shear Bond Strength (SBS) of orthodontic bracket bonded with Self-Etch Primers (SEP) and conventional acid etching system and to study the surface appearance of teeth after debonding; etching with conventional acid etch and self-etch priming, using stereomicroscope. Materials and Methods Five Groups (n=20) were created randomly from a total of 100 extracted premolars. In a control Group A, etching of enamel was done with 37% phosphoric acid and bonding of stainless steel brackets with Transbond XT (3M Unitek, Monrovia, California). Enamel conditioning in left over four Groups was done with self-etching primers and adhesives as follows: Group B-Transbond Plus (3M Unitek), Group C Xeno V+ (Dentsply), Group D-G-Bond (GC), Group E-One-Coat (Coltene). The Adhesive Remnant Index (ARI) score was also evaluated. Additionally, the surface roughness using profilometer were observed. Results Mean SBS of Group A was 18.26±7.5MPa, Group B was 10.93±4.02MPa, Group C was 6.88±2.91MPa while of Group D was 7.78±4.13MPa and Group E was 10.39±5.22MPa respectively. In conventional group ARI scores shows that over half of the adhesive was remaining on the surface of tooth (score 1 to 3). In self-etching primer groups ARI scores show that there was no or minor amount of adhesive remaining on the surface of tooth (score 4 and 5). SEP produces a lesser surface roughness on the enamel than conventional etching. However, statistical analysis shows significant correlation (p<0.001) of bond strength with surface roughness of enamel. Conclusion All groups might show clinically useful SBS values and Transbond XT can be successfully used for bracket bonding after enamel conditioning with any of the SEPs tested. The SEPs used in Groups C (Xeno V+) and D (G-Bond) have significantly lowered SBS. Although, the values might still be clinically acceptable. PMID:28208997

  13. An ex vivo comparison of three different gutta-percha cones when compacted at different temperatures: rheological considerations in relation to the filling of lateral canals.

    PubMed

    Venturi, M; Di Lenarda, R; Breschi, L

    2006-08-01

    To compare ex vivo the penetration of three brands of gutta-percha cones, compacted under a constant force and heated to different temperatures, into artificial lateral canals. Resin blocks with simulated main canals, each having two lateral canals (C at 6.5 and A at 13 mm from the surface of the resin block), were selected. A gutta-percha cone, either Mynol MF, Hygenic MF or GT Tulsa 0.04 was compacted into each main canal for 5 s using a wire rod with a diameter of 0.7 mm soldered to the bottom of a metal cylinder, with a force of 2.7 kg at controlled temperatures of 37, 42, 47, 52, 60 degrees C. The penetration of each brand of gutta-percha into 60 lateral canals (10 at each temperature) was measured using a stereomicroscope. Statistical analysis was performed using the ANOVA, the Scheffè test and the t-test. None of the three brands of cones entered up to 0.1 mm within either lateral canal until a temperature of 47 degrees C was reached; at that temperature only Mynol cones (P < or = 0.05) penetrated in four of 10 A-level canals (mean 0.13 +/- 0.19 mm) and in all 10 C-level canals (mean 0.43 +/- 0.12 mm). The A-level lateral canals were penetrated at 52 degrees C by Mynol cones (mean 0.76 +/- 0.34 mm) to a significantly greater distance (P < or = 0.05) than Tulsa cones (mean 0.31 +/- 0.12 mm) and Hygenic cones (mean 0.11 +/- 0.08 mm). At 60 degrees C the Mynol cones (mean 1.93 +/- 0.34 mm) penetrated significantly more (P < or = 0.05) than the Tulsa cones (mean 0.86 +/- 0.22 mm) and Hygenic cones (mean 0.67 +/- 0.19 mm). The C-level lateral canals were penetrated at 52 degrees C by Mynol cones (mean 0.91 +/- 0.29 mm) to a significantly greater distance (P < or = 0.05) than Tulsa cones (mean 0.47 +/- 0.16 mm) and Hygenic cones (mean 0.46 +/- 0.15 mm), whilst no significant difference was found at 60 degrees C. When heated and compacted, the three gutta-percha cones penetrated the lateral canals to different degrees. They penetrated more than 0.43 mm into the lateral canals only at temperatures higher than 47 degrees C.

  14. Analysis of Variance: What Is Your Statistical Software Actually Doing?

    ERIC Educational Resources Information Center

    Li, Jian; Lomax, Richard G.

    2011-01-01

    Users assume statistical software packages produce accurate results. In this article, the authors systematically examined Statistical Package for the Social Sciences (SPSS) and Statistical Analysis System (SAS) for 3 analysis of variance (ANOVA) designs, mixed-effects ANOVA, fixed-effects analysis of covariance (ANCOVA), and nested ANOVA. For each…

  15. [Design and implementation of online statistical analysis function in information system of air pollution and health impact monitoring].

    PubMed

    Lü, Yiran; Hao, Shuxin; Zhang, Guoqing; Liu, Jie; Liu, Yue; Xu, Dongqun

    2018-01-01

    To implement the online statistical analysis function in information system of air pollution and health impact monitoring, and obtain the data analysis information real-time. Using the descriptive statistical method as well as time-series analysis and multivariate regression analysis, SQL language and visual tools to implement online statistical analysis based on database software. Generate basic statistical tables and summary tables of air pollution exposure and health impact data online; Generate tendency charts of each data part online and proceed interaction connecting to database; Generate butting sheets which can lead to R, SAS and SPSS directly online. The information system air pollution and health impact monitoring implements the statistical analysis function online, which can provide real-time analysis result to its users.

  16. Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM

    PubMed Central

    Das, Sanjib; Pradhan, Prasanti Kumari; Lata, S.; Sinha, Sachidananda Prasad

    2018-01-01

    Introduction: The purpose of this study was to compare the incidence of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex electrodischarge machining (HEDM). Materials and Methods: A total of 75 extracted mandibular premolars were selected. The root canals were instrumented using ProTaper Next, OneShape, and HEDM rotary files. All roots were horizontally sectioned at 3, 6, and 9 mm from apex with slow-speed saw under water cooling. The sections were observed under a stereomicroscope at ×25 to determine the absence or presence of crack. Data were analyzed using post hoc test and one-way ANOVA. Results: ProTaper Next and HEDM produced significantly less cracks than OneShape. Conclusion: Within the limitation of this in vitro study, it can be concluded that nickel–titanium instruments may cause cracks on the root surface. ProTaper Next and HEDM tend to produce less number of cracks as compared to OneShape. PMID:29674816

  17. Application of hanging drop technique to optimize human IgG formulations.

    PubMed

    Li, Guohua; Kasha, Purna C; Late, Sameer; Banga, Ajay K

    2010-01-01

    The purpose of this work is to assess the hanging drop technique in screening excipients to develop optimal formulations for human immunoglobulin G (IgG). A microdrop of human IgG and test solution hanging from a cover slide and undergoing vapour diffusion was monitored by a stereomicroscope. Aqueous solutions of IgG in the presence of different pH, salt concentrations and excipients were prepared and characterized. Low concentration of either sodium/potassium phosphate or McIlvaine buffer favoured the solubility of IgG. Addition of sucrose favoured the stability of this antibody while addition of NaCl caused more aggregation. Antimicrobial preservatives were also screened and a complex effect at different buffer conditions was observed. Dynamic light scattering, differential scanning calorimetry and size exclusion chromatography studies were performed to further validate the results. In conclusion, hanging drop is a very easy and effective approach to screen protein formulations in the early stage of formulation development.

  18. Practical Guide for Ascidian Microinjection: Phallusia mammillata.

    PubMed

    Yasuo, Hitoyoshi; McDougall, Alex

    2018-01-01

    Phallusia mammillata has recently emerged as a new ascidian model. Its unique characteristics, including the optical transparency of eggs and embryos and efficient translation of exogenously introduced mRNA in eggs, make the Phallusia system suitable for fluorescent protein (FP)-based imaging approaches. In addition, genomic and transcriptomic resources are readily available for this ascidian species, facilitating functional gene studies. Microinjection is probably the most versatile technique for introducing exogenous molecules such as plasmids, mRNAs, and proteins into ascidian eggs/embryos. However, it is not practiced widely within the community; presumably, because the system is rather laborious to set up and it requires practice. Here, we describe in as much detail as possible two microinjection methods that we use daily in the laboratory: one based on an inverted microscope and the other on a stereomicroscope. Along the stepwise description of system setup and injection procedure, we provide practical tips in the hope that this chapter might be a useful guide for introducing or improving a microinjection setup.

  19. Influence of calcium hydroxide debris on the quality of endodontic apical seal.

    PubMed

    Contardo, L; De Luca, M; Bevilacqua, L; Breschi, L; Di Lenarda, R

    2007-10-01

    The aim of the study was to study investigate the influence of calcium hydroxide used as intermediate medication on the quality of apical seal of a silicon based and an experimental resin based endodontic sealer. Eighty endodontic canals were prepared and divided in four groups. Calcium hydroxide was applied in groups 2 and 4. After 7 days, medication was removed and canals were filled with gutta-percha and RoekoSeal Automix (groups 1 and 2) or Scotchbond MP+C&B cement B (groups 3 and 4). Specimens were placed into India ink, cleared and analyzed under a stereomicroscope to investigate apical leakage. Specimens that received calcium hydroxide medication showed leakage means higher than the corresponding untreated ones (i.e. group 1< group 2 and group 3< group 4; P<0.001). Calcium hydroxide interferes with the sealing ability of silicon based sealer, since it frequently remains entrapped within the endodontic space even after careful removal procedures.

  20. The use of near-infrared photography to image fired bullets and cartridge cases.

    PubMed

    Stein, Darrell; Yu, Jorn Chi Chung

    2013-09-01

    An imaging technique that is capable of reducing glare, reflection, and shadows can greatly assist the process of toolmarks comparison. In this work, a camera with near-infrared (near-IR) photographic capabilities was fitted with an IR filter, mounted to a stereomicroscope, and used to capture images of toolmarks on fired bullets and cartridge cases. Fluorescent, white light-emitting diode (LED), and halogen light sources were compared for use with the camera. Test-fired bullets and cartridge cases from different makes and models of firearms were photographed under either near-IR or visible light. With visual comparisons, near-IR images and visible light images were comparable. The use of near-IR photography did not reveal more details and could not effectively eliminate reflections and glare associated with visible light photography. Near-IR photography showed little advantages in manual examination of fired evidence when it was compared with visible light (regular) photography. © 2013 American Academy of Forensic Sciences.

  1. A Handbook of Sound and Vibration Parameters

    DTIC Science & Technology

    1978-09-18

    fixed in space. (Reference 1.) no motion atay node Static Divergence: (See Divergence.) Statistical Energy Analysis (SEA): Statistical energy analysis is...parameters of the circuits come from statistics of the vibrational characteristics of the structure. Statistical energy analysis is uniquely successful

  2. General specifications for the development of a USL NASA PC R and D statistical analysis support package

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Bassari, Jinous; Triantafyllopoulos, Spiros

    1984-01-01

    The University of Southwestern Louisiana (USL) NASA PC R and D statistical analysis support package is designed to be a three-level package to allow statistical analysis for a variety of applications within the USL Data Base Management System (DBMS) contract work. The design addresses usage of the statistical facilities as a library package, as an interactive statistical analysis system, and as a batch processing package.

  3. Statistical Tutorial | Center for Cancer Research

    Cancer.gov

    Recent advances in cancer biology have resulted in the need for increased statistical analysis of research data.  ST is designed as a follow up to Statistical Analysis of Research Data (SARD) held in April 2018.  The tutorial will apply the general principles of statistical analysis of research data including descriptive statistics, z- and t-tests of means and mean

  4. Quantitative Methods for Analysing Joint Questionnaire Data: Exploring the Role of Joint in Force Design

    DTIC Science & Technology

    2015-08-01

    the nine questions. The Statistical Package for the Social Sciences ( SPSS ) [11] was used to conduct statistical analysis on the sample. Two types...constructs. SPSS was again used to conduct statistical analysis on the sample. This time factor analysis was conducted. Factor analysis attempts to...Business Research Methods and Statistics using SPSS . P432. 11 IBM SPSS Statistics . (2012) 12 Burns, R.B., Burns, R.A. (2008) ‘Business Research

  5. [The use of the stereomicroscopy in the forensic medicine practice].

    PubMed

    Valent, D

    2010-10-01

    In everyday medico-legal practice the situations occur when it is necessary to magnify something and bring it up to the level of magnifying glass and closer to the eye of the examiner, and this way to determine the character of wounds, the way and angle of the attack, vicinity of the instrument of assault and where necessary also to determine the option of other person being present and causing the injury mentioned above. One of the options which enables the forensic pathologist to evaluate the case is the stereomicroscopic examination. It can be done at the place of the autopsy being performed (in vivo) and also in a laboratory (in vitro) after taking samples. The objective of the work is to present methodically quite simple, for time, space and finances not too demanding a method, the results of which is possible to apply in medico-legal practice. The work provides the inside of the cases selected by the author in which the stereomicroscopy has been used as one of the examination methods. The clothing of the victim was examined where the victim suffered thoracic injury caused by gunshot in one case, and the skin and parietal bone in the second case of gunshot injury of the head. Furthermore the appearance of stabbing wounds to the skin was investigated with the identification of angles, of the residue of the paint of a motor vehicle on the clothing of a female pedestrian; and the plant seeds obtained from the crime scene which were found on the body of the victim namely in the head wounds. By further investigations into these cases other options were discovered as to the next more detailed examinations of the cases and the confirmation of the diagnosis. There is a certain value in the photo documentation which was made with every case. Stereomicroscopic examination is a suitable method by means of which it is possible to follow all the morphological findings which the forensic pathologist has to deal with in his work. It significantly broadens the knowledge spectre and the substance and the meaning of the autopsy as such, i. e. it supports the process of determination of the cause of death and the circumstances of the death. It is a simple method which has a great potential to become one of the major investigation methods. The author is the first to present the results of using of the stereomicroscopy in our conditions. This method is not even often used abroad.

  6. Image-analysis library

    NASA Technical Reports Server (NTRS)

    1980-01-01

    MATHPAC image-analysis library is collection of general-purpose mathematical and statistical routines and special-purpose data-analysis and pattern-recognition routines for image analysis. MATHPAC library consists of Linear Algebra, Optimization, Statistical-Summary, Densities and Distribution, Regression, and Statistical-Test packages.

  7. Comparing Visual and Statistical Analysis of Multiple Baseline Design Graphs.

    PubMed

    Wolfe, Katie; Dickenson, Tammiee S; Miller, Bridget; McGrath, Kathleen V

    2018-04-01

    A growing number of statistical analyses are being developed for single-case research. One important factor in evaluating these methods is the extent to which each corresponds to visual analysis. Few studies have compared statistical and visual analysis, and information about more recently developed statistics is scarce. Therefore, our purpose was to evaluate the agreement between visual analysis and four statistical analyses: improvement rate difference (IRD); Tau-U; Hedges, Pustejovsky, Shadish (HPS) effect size; and between-case standardized mean difference (BC-SMD). Results indicate that IRD and BC-SMD had the strongest overall agreement with visual analysis. Although Tau-U had strong agreement with visual analysis on raw values, it had poorer agreement when those values were dichotomized to represent the presence or absence of a functional relation. Overall, visual analysis appeared to be more conservative than statistical analysis, but further research is needed to evaluate the nature of these disagreements.

  8. A note on generalized Genome Scan Meta-Analysis statistics

    PubMed Central

    Koziol, James A; Feng, Anne C

    2005-01-01

    Background Wise et al. introduced a rank-based statistical technique for meta-analysis of genome scans, the Genome Scan Meta-Analysis (GSMA) method. Levinson et al. recently described two generalizations of the GSMA statistic: (i) a weighted version of the GSMA statistic, so that different studies could be ascribed different weights for analysis; and (ii) an order statistic approach, reflecting the fact that a GSMA statistic can be computed for each chromosomal region or bin width across the various genome scan studies. Results We provide an Edgeworth approximation to the null distribution of the weighted GSMA statistic, and, we examine the limiting distribution of the GSMA statistics under the order statistic formulation, and quantify the relevance of the pairwise correlations of the GSMA statistics across different bins on this limiting distribution. We also remark on aggregate criteria and multiple testing for determining significance of GSMA results. Conclusion Theoretical considerations detailed herein can lead to clarification and simplification of testing criteria for generalizations of the GSMA statistic. PMID:15717930

  9. Predictive value of bovine follicular components as markers of oocyte developmental potential.

    PubMed

    Matoba, Satoko; Bender, Katrin; Fahey, Alan G; Mamo, Solomon; Brennan, Lorraine; Lonergan, Patrick; Fair, Trudee

    2014-01-01

    The follicle is a unique micro-environment within which the oocyte can develop and mature to a fertilisable gamete. The aim of this study was to investigate the ability of a panel of follicular parameters, including intrafollicular steroid and metabolomic profiles and theca, granulosa and cumulus cell candidate gene mRNA abundance, to predict the potential of bovine oocytes to develop to the blastocyst stage in vitro. Individual follicles were dissected from abattoir ovaries, carefully ruptured under a stereomicroscope and the oocyte was recovered and individually processed through in vitro maturation, fertilisation and culture. The mean (±s.e.m.) follicular concentrations of testosterone (62.8±4.8 ngmL(-1)), progesterone (616.8±31.9 ngmL(-1)) and oestradiol (14.4±2.4 ngmL(-1)) were not different (P>0.05) between oocytes that formed (competent) or failed to form (incompetent) blastocysts. Principal-component analysis of the quantified aqueous metabolites in follicular fluid showed differences between oocytes that formed blastocysts and oocytes that degenerated; l-alanine, glycine and l-glutamate were positively correlated and urea was negatively correlated with blastocyst formation. Follicular fluid associated with competent oocytes was significantly lower in palmitic acid (P=0.023) and total fatty acids (P=0.031) and significantly higher in linolenic acid (P=0.036) than follicular fluid from incompetent oocytes. Significantly higher (P<0.05) transcript abundance of LHCGR in granulosa cells, ESR1 and VCAN in thecal cells and TNFAIP6 in cumulus cells was associated with competent compared with incompetent oocytes.

  10. Nacre formation by epithelial cell cultures from mantle of the black-lip pearl oyster, Pinctada margaritifera.

    PubMed

    Jayasankar, Vidya; Vasudevan, Srinivasa Raghavan; Poulose, Suja C; Divipala, Indira

    2018-06-12

    Mantle tissue from the black-lip pearl oyster, Pinctada margaritifera, was cultured in vitro using sterilized seawater supplemented with 0.1% yeast extract as the culture medium. Granular and agranular epithelial cells, hyalinocytes, and fibroblast-like cells were observed in the initial stages of culture. Epithelial cells later formed pseudopodial cell networks containing clusters of granulated cells, which upon maturation released their colored granules. These granules induced formation of nacre crystal deposits on the bottom of the culture plate. Cultures comprised of only granulated epithelial cells were established through periodic sub-culturing of mantle cells and maintained for over 18 mo in a viable condition. Reverse transcriptase PCR of cultured cells demonstrated gene expression of the shell matrix protein, nacrein. To further evaluate the functional ability of cultured granulated epithelial cells, nuclear shell beads were incubated in culture medium containing these cells to induce nacre formation on the beads. Observation of the bead surface under a stereomicroscope at periodic intervals showed the gradual formation of blackish yellow colored nacre deposits. Examination of the bead surface by scanning electron microscopy and energy dispersive X-ray analysis at periodic intervals revealed a distinct brick and mortar formation characteristic of nacre, comprised of aragonite platelets and matrix proteins. Calcium, carbon, and oxygen were the major elements in all stages examined. Our study shows that mantle epithelial cells in culture retain the ability to secrete nacre and can therefore form the basis for future studies on the biomineralization process and its application in development of sustainable pearl culture.

  11. Diagnostic analysis of stone materials from underwater excavations: the case study of the Roman archaeological site of Baia (Naples, Italy)

    NASA Astrophysics Data System (ADS)

    Aloise, P.; Ricca, M.; La Russa, M. F.; Ruffolo, S. A.; Belfiore, C. M.; Padeletti, G.; Crisci, G. M.

    2014-03-01

    This work belongs to the framework of the national research project "COMAS" (Planned COnservation, " in situ", of underwater archaeological artifacts), funded by the Italian Ministry of Education, Universities and Research (MIUR), concerning the submarine archaeological area of Baia (Naples, Italy). The site includes remains of the ancient cities of Baiae and Portus Iulius, which, since the 4th century AD, started to be submerged because of the bradyseism phenomenon. The work aims to the characterization of four different types of stone materials collected from the site, specifically marbles, limestones, ignimbrites, and bricks, in order to investigate their state of conservation. In particular, specimens were sampled from some masonry structures and pavement slabs ( opus sectile) in a specific area of the submerged site, called " Villa a Protiro". In order to characterize archaeological samples from a mineralogical-petrographic point of view, polarized optical microscopy and X-ray diffraction analyses were carried out, while to assess their conservation state, the surface colonization by biodeteriogen agents and their interaction with the substrate were studied through observations under a stereomicroscope, scanning electron microscopy and Fourier transform infrared spectroscopy. Marble and limestone samples revealed an intense bioerosion phenomena, attributable to epilithic and endolithic forms, particularly boring sponges. On the contrary, ignimbrites suffer a lower degree of biological colonization related to the activity of other species, such as serpulids and bryozoans. In bricks, biocolonisation is correlated to the type of temper used in the artifact, the quartz pastes having a greater susceptibility to biological attack than the volcanic ones.

  12. Effect of prior silane application on the bond strength of a universal adhesive to a lithium disilicate ceramic.

    PubMed

    Moro, André Fábio Vasconcelos; Ramos, Amanda Barreto; Rocha, Gustavo Miranda; Perez, Cesar Dos Reis

    2017-11-01

    Universal adhesives combine silane and various monomers in a single bottle to make them more versatile. Their adhesive performance is unclear. The purpose of this in vitro study was to assess the effects of an additional silane application before using a universal adhesive on the adhesion between a disilicate glass ceramic and a composite resin by using a microshear bond strength test (μSBS) and fracture analysis immediately and after thermocycling. One hundred lithium disilicate glass ceramic disks were divided into 10 groups for bond strength testing according to the following 3 surface treatments: silane application (built-in universal adhesive or with additional application), adhesive (Adper Single Bond Plus [SB, 3M ESPE], Scotchbond Universal Adhesive [U, 3M ESPE], and mixed U with Dual Cure Activator [DCA, 3M ESPE]); or thermocycling (half of the specimens were thermocycled 10000 times). After surface treatment, 5 resin cylinders were bonded to each disk and submitted to a μSBS test. The failure mode was analyzed under a stereomicroscope and evaluated by scanning electron microscope and energy-dispersive x-ray spectroscopy. Data from the μSBS test were analyzed by 3-way ANOVA followed by the Tukey HSD post hoc test (α=.05). An additional silane application resulted in a higher μSBS result for all adhesive groups (P<.05). Ceramic surface treatment influenced the performance of adhesives, which may be improved with an additional silane application. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Remineralization Potential of Three Tooth Pastes on Enamel Caries.

    PubMed

    Singhal, Rajnish K; Rai, Balwant

    2017-08-15

    Different formulations of dentifrices exist in the market. Usually, single toothpaste is used by all family members including children. There is a big concern of fluoride ingestion with the toothpaste containing high fluoride content in children. Recently, new toothpaste (including toothpaste) with remineralization potential without fluoride content has been formulated. There is an urgent need to compare remineralization potential of this new formulation with the exiting dentifrices. Therefore, the present study has been undertaken to assess and compare the remineralization potential of three dentifrices with different compositions on artificially induced carious lesions in vitro by using scanning electron microscopy and polarised light microscopy. The present in vitro study was conducted on 21 healthy extracted primary central incisor teeth surfaces, which were divided into three groups and were treated by three different dentifrices. Artificial demineralization was followed by remineralization using dentifrice slurry as per the group distribution. All the samples were studied for remineralization by using scanning electron microscopy and polarised light microscopy. Data were analysed using SPSS version 11 software. A significant difference was found between the remineralization potential of incudent toothpaste and other toothpaste groups based on the analysis of polarised light microscopy and stereomicroscope. The remineralizing ability of incudent toothpaste for artificial enamel lesions was found to be significantly higher than that of Colgate® and Crest toothpaste. The limitations of this study include, being a short term study, low sample size and in vitro experiment. incudent toothpaste has exhibited a higher remineralizing potential as compared to fluoride based toothpaste in our study.

  14. Effects of gibberellic acid on hemocytes of Galleria mellonella L. (Lepidoptera: Pyralidae).

    PubMed

    Altuntaş, H; Kılıç, A Y; Uçkan, F; Ergin, E

    2012-06-01

    The impacts of different doses of the plant growth regulator gibberellic acid (GA(3)) in diet on the number of total and differential hemocytes, frequency of apoptotic, and necrotic hemocytes, mitotic indices, encapsulation, and melanization responses were investigated using the greater wax moth Galleria mellonella L. (Lepidoptera: Pyralidae) larvae. Total hemocyte counts increased in G. mellonella larvae at all treatment doses whereas GA(3) application had no effect on the number of different hemocyte types. The occurrence of apoptosis, necrosis and mitotic indices in GA(3) treated and untreated last instars were detected by acridine orange or ethidium bromide double staining by fluorescence microscopy. While the ratio of necrotic hemocytes increased at all GA(3) treatments, that of late apoptotic cells was only higher at doses >200 ppm when compared with untreated larvae. The percentage of mitotic index also increased at 5,000 ppm. Positively charged DEAE Sephadex A-25 beads were used for analysis of the levels of encapsulation and melanization in GA(3) treated G. mellonella larvae. At four and 24 h posttreatments with Sephadex A-25 bead injection, insects were dissected under a stereomicroscope. Encapsulation rates of larval hemocytes were dependent on the extent of encapsulation and time but not treatment groups. While the extent of melanization of hemocytes showed differences related to time, in general, a decrease was observed at all doses of GA(3) treated larvae at 24 h. We suggest that GA(3) treatment negatively affects hemocyte physiology and cell immune responses inducing cells to die by necrosis and apoptosis in G. mellonella larvae.

  15. Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?

    PubMed

    Del Balso, Christopher; Teeter, Matthew G; Tan, Sok Chuen; Howard, James L; Lanting, Brent A

    2016-10-01

    Wear and tribocorrosion at the modular head-neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation endeavored to elucidate the effect of femoral head diameter on fretting and corrosion in retrieved head-neck tapers. A retrieval analysis of THA prostheses in vivo for a minimum of 1 year was performed. Twenty-three femoral heads of 32-mm diameter were matched with 28-mm heads based on time in vivo and head length (-3 mm to +8 mm). All included implants featured a single taper design from a single manufacturer. Fretting and corrosion damage scoring was performed for each implant under stereomicroscopic visualization. Head diameter was observed to affect fretting (P = .01), with 32-mm femoral heads exhibiting greater total fretting scores than 28-mm heads. Fretting damage was greatest (P = .01) in the central concentric zone of the femoral head bore tapers, regardless of head diameter, length, or stem offset. No significant effect on total corrosion scores was observed for any head or stem variable. Retrieved implant total corrosion scores were positively correlated (ρ = 0.51, P < .001) with implantation time. Increased femoral head diameter in THA may produce greater fretting damage owing to and increased head-neck moment arm. There is no associated increase in corrosion with 28-mm and 32-mm heads of this taper design. The longer a THA prosthesis is implanted, the greater the risk of damage due to corrosion. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Evaluation of tensile retention of Y-TZP crowns after long-term aging: effect of the core substrate and crown surface conditioning.

    PubMed

    Amaral, R; Rippe, M; Oliveira, B G; Cesar, P F; Bottino, M A; Valandro, L F

    2014-01-01

    This study evaluated the effect of the core substrate type (dentin and composite resin) on the retention of crowns made of yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP), submitted to three inner surface conditionings. For this purpose, 72 freshly extracted molars were embedded in acrylic resin, perpendicular to the long axis, and prepared for full crowns: 36 specimens had crown preparations in dentin; the remaining 36 teeth had the crowns removed, and crown preparations were reconstructed with composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and 72 Y-TZP copings for the tensile test were produced. Cementation was performed with a dual-cured cement containing phosphate monomers. For cementation, the crown preparation (dentin or resin) was conditioned with the adhesive system, and the ceramic was subjected to one of three surface treatments: isopropyl alcohol, tribochemical silica coating, or thin low-fusing glassy porcelain layer application plus silanization. After 24 hours, all specimens were submitted to thermocycling (6000 cycles) and placed in a special tensile testing device in a universal testing machine to determine failure loads. The failure modes of all samples were analyzed under a stereomicroscope. Two-way analysis of variance showed that the surface treatment and substrate type (α=0.05) affected the tensile retention results. The dentin substrate presented the highest tensile retention values, regardless of the surface treatment. When the substrate was resin, the tribochemical silica coating and low-fusing glaze application plus silanization groups showed the higher retention values.

  17. Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.

    PubMed

    Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B

    2017-03-01

    To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.

  18. The Effect of 3% Phosphate Ascorbyl Gel on Bond Strength of Composite Resin to Enamel treated with 35% Hydrogen Peroxide.

    PubMed

    de Castro, Milena de Fátima Schalcher; Silva, Alice Carvalho; Franco, Marcela Mayana Pereira; Silva, Ana Paula Brito; Bramante, Fausto da Silva; da Silva, Monica Barros; Lima, Darlon Martins; Pereira, Adriana de Fátima Vasconcelos

    2015-05-01

    To evaluate the effect of 3% phosphate ascorbyl gel (PA) in different times onto the microshear bond strength of composite resin (CR) to bovine enamel treated with 35% hydrogen peroxide (HP). Thirty enamel blocks of bovine incisors were made and divided into 5 groups (n = 6) with three specimens per group (n = 18), according to treatment: G1= No bleaching + CR; G2 = HP + CR after 15d; G3 = HP + CR after 24 hours; G4 = HP + PA (15 min) + CR after 24 hours; G5 = HP + PA (2 hours) + CR after 24 hours. The resin cylinders were made by Tygon matrices. Microshear bond strength test was performed using universal testing machine with a 50N load at a speed of 0.5 mm/min. Fracture modes were assessed by a stereomicroscope 40 ×. Microshear bond strength values were submitted to the analysis of variance (ANOVA) one-way and Tukey test (p < 0.05). G1 had significant results when compared to G3 and G5 (p < 0.01). However, G2, G3, G4 and G5 have showed no significant differences among groups (p > 0.05). Failure modes were categorized into adhesive (90%) and mixed (10%). The use of 3% phosphate ascorbyl gel for 15 minutes was able to improve bond strength of composite resin to bleached bovine enamel, but when 3% phosphate ascorbyl gel was applied during 40 minutes it negatively interfered in the adhesion of the resin to bleached bovine enamel.

  19. Effect of Different Torque Settings on Crack Formation in Root Dentin.

    PubMed

    Dane, Asım; Capar, Ismail Davut; Arslan, Hakan; Akçay, Merve; Uysal, Banu

    2016-02-01

    The aim of the present study was to observe the incidence of cracks in root canal dentin using the ProTaper Universal system (Dentsply Maillefer, Ballaigues, Switzerland) at low- and high-torque settings. Sixty-nine mandibular premolar teeth that had been extracted for different reasons were selected. The teeth were divided into 3 groups: an unprepared control group, a low-torque settings group (SX = 3, S1 = 2, S2 = 1, F1 = 1.5, F2 = 2, F3 = 2, F4 = 2 N/cm), and a high-torque settings group (SX = 4, S1 = 4, S2 = 1.5, F1 = 2, F2 = 3, F3 = 3, F4 = 3 N/cm). After a root canal procedure, all the teeth were horizontally sectioned at 2, 4, 6, and 8 mm from the apex. Then, under a stereomicroscope, all the slices were examined to determine the presence of cracks. A chi-square test was used for data analysis. The significance level was set at P = .05. There were no cracks in the unprepared control group. Vertical root fractures were not observed in any of the groups. There were significantly fewer cracks (17.4% of the sections) in the low-torque group than in the high-torque group (29.4% of the sections) (P < .05). In this in vitro study, the instrumentation of root canals with the ProTaper Universal instrument caused more crack formation in root canal dentin at high-torque than at low-torque settings. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Meta-analysis and The Cochrane Collaboration: 20 years of the Cochrane Statistical Methods Group

    PubMed Central

    2013-01-01

    The Statistical Methods Group has played a pivotal role in The Cochrane Collaboration over the past 20 years. The Statistical Methods Group has determined the direction of statistical methods used within Cochrane reviews, developed guidance for these methods, provided training, and continued to discuss and consider new and controversial issues in meta-analysis. The contribution of Statistical Methods Group members to the meta-analysis literature has been extensive and has helped to shape the wider meta-analysis landscape. In this paper, marking the 20th anniversary of The Cochrane Collaboration, we reflect on the history of the Statistical Methods Group, beginning in 1993 with the identification of aspects of statistical synthesis for which consensus was lacking about the best approach. We highlight some landmark methodological developments that Statistical Methods Group members have contributed to in the field of meta-analysis. We discuss how the Group implements and disseminates statistical methods within The Cochrane Collaboration. Finally, we consider the importance of robust statistical methodology for Cochrane systematic reviews, note research gaps, and reflect on the challenges that the Statistical Methods Group faces in its future direction. PMID:24280020

  1. Statistical Tutorial | Center for Cancer Research

    Cancer.gov

    Recent advances in cancer biology have resulted in the need for increased statistical analysis of research data.  ST is designed as a follow up to Statistical Analysis of Research Data (SARD) held in April 2018.  The tutorial will apply the general principles of statistical analysis of research data including descriptive statistics, z- and t-tests of means and mean differences, simple and multiple linear regression, ANOVA tests, and Chi-Squared distribution.

  2. Interfaces between statistical analysis packages and the ESRI geographic information system

    NASA Technical Reports Server (NTRS)

    Masuoka, E.

    1980-01-01

    Interfaces between ESRI's geographic information system (GIS) data files and real valued data files written to facilitate statistical analysis and display of spatially referenced multivariable data are described. An example of data analysis which utilized the GIS and the statistical analysis system is presented to illustrate the utility of combining the analytic capability of a statistical package with the data management and display features of the GIS.

  3. Cognition of and Demand for Education and Teaching in Medical Statistics in China: A Systematic Review and Meta-Analysis

    PubMed Central

    Li, Gaoming; Yi, Dali; Wu, Xiaojiao; Liu, Xiaoyu; Zhang, Yanqi; Liu, Ling; Yi, Dong

    2015-01-01

    Background Although a substantial number of studies focus on the teaching and application of medical statistics in China, few studies comprehensively evaluate the recognition of and demand for medical statistics. In addition, the results of these various studies differ and are insufficiently comprehensive and systematic. Objectives This investigation aimed to evaluate the general cognition of and demand for medical statistics by undergraduates, graduates, and medical staff in China. Methods We performed a comprehensive database search related to the cognition of and demand for medical statistics from January 2007 to July 2014 and conducted a meta-analysis of non-controlled studies with sub-group analysis for undergraduates, graduates, and medical staff. Results There are substantial differences with respect to the cognition of theory in medical statistics among undergraduates (73.5%), graduates (60.7%), and medical staff (39.6%). The demand for theory in medical statistics is high among graduates (94.6%), undergraduates (86.1%), and medical staff (88.3%). Regarding specific statistical methods, the cognition of basic statistical methods is higher than of advanced statistical methods. The demand for certain advanced statistical methods, including (but not limited to) multiple analysis of variance (ANOVA), multiple linear regression, and logistic regression, is higher than that for basic statistical methods. The use rates of the Statistical Package for the Social Sciences (SPSS) software and statistical analysis software (SAS) are only 55% and 15%, respectively. Conclusion The overall statistical competence of undergraduates, graduates, and medical staff is insufficient, and their ability to practically apply their statistical knowledge is limited, which constitutes an unsatisfactory state of affairs for medical statistics education. Because the demand for skills in this area is increasing, the need to reform medical statistics education in China has become urgent. PMID:26053876

  4. Cognition of and Demand for Education and Teaching in Medical Statistics in China: A Systematic Review and Meta-Analysis.

    PubMed

    Wu, Yazhou; Zhou, Liang; Li, Gaoming; Yi, Dali; Wu, Xiaojiao; Liu, Xiaoyu; Zhang, Yanqi; Liu, Ling; Yi, Dong

    2015-01-01

    Although a substantial number of studies focus on the teaching and application of medical statistics in China, few studies comprehensively evaluate the recognition of and demand for medical statistics. In addition, the results of these various studies differ and are insufficiently comprehensive and systematic. This investigation aimed to evaluate the general cognition of and demand for medical statistics by undergraduates, graduates, and medical staff in China. We performed a comprehensive database search related to the cognition of and demand for medical statistics from January 2007 to July 2014 and conducted a meta-analysis of non-controlled studies with sub-group analysis for undergraduates, graduates, and medical staff. There are substantial differences with respect to the cognition of theory in medical statistics among undergraduates (73.5%), graduates (60.7%), and medical staff (39.6%). The demand for theory in medical statistics is high among graduates (94.6%), undergraduates (86.1%), and medical staff (88.3%). Regarding specific statistical methods, the cognition of basic statistical methods is higher than of advanced statistical methods. The demand for certain advanced statistical methods, including (but not limited to) multiple analysis of variance (ANOVA), multiple linear regression, and logistic regression, is higher than that for basic statistical methods. The use rates of the Statistical Package for the Social Sciences (SPSS) software and statistical analysis software (SAS) are only 55% and 15%, respectively. The overall statistical competence of undergraduates, graduates, and medical staff is insufficient, and their ability to practically apply their statistical knowledge is limited, which constitutes an unsatisfactory state of affairs for medical statistics education. Because the demand for skills in this area is increasing, the need to reform medical statistics education in China has become urgent.

  5. Common pitfalls in statistical analysis: Clinical versus statistical significance

    PubMed Central

    Ranganathan, Priya; Pramesh, C. S.; Buyse, Marc

    2015-01-01

    In clinical research, study results, which are statistically significant are often interpreted as being clinically important. While statistical significance indicates the reliability of the study results, clinical significance reflects its impact on clinical practice. The third article in this series exploring pitfalls in statistical analysis clarifies the importance of differentiating between statistical significance and clinical significance. PMID:26229754

  6. Transit safety & security statistics & analysis 2003 annual report (formerly SAMIS)

    DOT National Transportation Integrated Search

    2005-12-01

    The Transit Safety & Security Statistics & Analysis 2003 Annual Report (formerly SAMIS) is a compilation and analysis of mass transit accident, casualty, and crime statistics reported under the Federal Transit Administrations (FTAs) National Tr...

  7. Transit safety & security statistics & analysis 2002 annual report (formerly SAMIS)

    DOT National Transportation Integrated Search

    2004-12-01

    The Transit Safety & Security Statistics & Analysis 2002 Annual Report (formerly SAMIS) is a compilation and analysis of mass transit accident, casualty, and crime statistics reported under the Federal Transit Administrations (FTAs) National Tr...

  8. On Conceptual Analysis as the Primary Qualitative Approach to Statistics Education Research in Psychology

    ERIC Educational Resources Information Center

    Petocz, Agnes; Newbery, Glenn

    2010-01-01

    Statistics education in psychology often falls disappointingly short of its goals. The increasing use of qualitative approaches in statistics education research has extended and enriched our understanding of statistical cognition processes, and thus facilitated improvements in statistical education and practices. Yet conceptual analysis, a…

  9. Time Series Analysis Based on Running Mann Whitney Z Statistics

    USDA-ARS?s Scientific Manuscript database

    A sensitive and objective time series analysis method based on the calculation of Mann Whitney U statistics is described. This method samples data rankings over moving time windows, converts those samples to Mann-Whitney U statistics, and then normalizes the U statistics to Z statistics using Monte-...

  10. Stable isotope analysis of food-web system in subarctic to subtropical region of western North Pacific

    NASA Astrophysics Data System (ADS)

    Aita, M. N.; Minoru, K.; Kobari, T.; Yoshikawa, C.; Ishii, R.

    2016-02-01

    Carbon and nitrogen isotope ratios of biota are controlled by two factors, a metabolic system and a lifestyle of predator and a regional variability of environmental parameters on food web system. To evaluate the environmental factors (i.e., nutrients and temperature) on the basic food web in the marine ecosystem. We studied the seasonal variation of nitrogen and carbon isotope ratios of zooplankton in the subarctic site of K2 (47ºN, 160ºE) and the subtropical one of S1 (30ºN, 145ºE) in the western North Pacific Ocean, both of which are JAMSTEC observation site. Biota were collected in eight depths (0-50, 50-100, 100-150, 150-200, 200-300, 300-500, 500-750, 750-1000m) at both sites using IONESS from February 2010 to July 2011. All samples were classified under a stereomicroscope into species or genus level and used adult stage for isotopic analysis. We also collected water samples from seasonal and vertical (from the surface to 1,000m depth) profiles in δ15N (NO3+ + NO2-) at K2 and S1 in special reference to nitrogen cycles. The δ15N and δ13C values of amphipods and copepod, omnivorous zooplankton in the surface ocean, showed a large seasonal variation. The δ15N values of zooplankton and nitrate ions in the water at the S1 site tended to be lower than those at the K2 site, indicating that the basic food web could be affected by nitrogen fixation. We further compared the trophic fractionation of carbon and nitrogen isotopes (Δδ13C, Δδ15N). It was observed that a simple relationship exists in the Δδ15N/Δδ13C regardless of species and ecosystems. This contention suggests a unified regularity is maintained in the lower to higher trophic level in the marine ecosystem.

  11. Pollination drop in Juniperus communis: response to deposited material.

    PubMed

    Mugnaini, Serena; Nepi, Massimo; Guarnieri, Massimo; Piotto, Beti; Pacini, Ettore

    2007-12-01

    The pollination drop is a liquid secretion produced by the ovule and exposed outside the micropyle. In many gymnosperms, pollen lands on the surface of the pollination drop, rehydrates and enters the ovule as the drop retracts. The objective of this work was to study the formation of the pollination drop in Juniperus communis, its carbohydrate composition and the response to deposition of conspecific pollen, foreign pollen and other particulate material, in an attempt to clarify the mechanism of pollination drop retraction. Branches with female cones close to pollination drop secretion were collected. On the first day of pollination drop exposure, an eyelash mounted on a wooden stick with paraffin was used to collect pollen or silica gel particles, which were then deposited by contact with the drop. Volume changes in pollination drops were measured by using a stereomicroscope with a micrometer eyepiece 3 h after deposition. The volume of non-pollinated control drops was also recorded. On the first day of secretion, drops were also collected for sugar analysis by high-performance liquid chromatography. The pollination drop persisted for about 12 d if not pollinated, and formed again after removal for up to four consecutive days. After pollination with viable conspecific pollen, the drop retracted quickly and did not form again. Partial withdrawal occurred after deposition of other biological and non-biological material. Fructose was the dominant sugar; glucose was also present but at a much lower percentage. Sugar analysis confirmed the general trend of fructose dominance in gymnosperm pollination drops. Complete pollination drop withdrawal appears to be triggered by a biochemical mechanism resulting from interaction between pollen and drop constituents. The results of particle deposition suggest the existence of a non-specific, particle-size-dependent mechanism that induces partial pollination drop withdrawal. These results suggest that the non-specific response may decrease the probability of pollen landing on the drop, reducing pollination efficiency.

  12. Pollination Drop in Juniperus communis: Response to Deposited Material

    PubMed Central

    Mugnaini, Serena; Nepi, Massimo; Guarnieri, Massimo; Piotto, Beti; Pacini, Ettore

    2007-01-01

    Background and Aims The pollination drop is a liquid secretion produced by the ovule and exposed outside the micropyle. In many gymnosperms, pollen lands on the surface of the pollination drop, rehydrates and enters the ovule as the drop retracts. The objective of this work was to study the formation of the pollination drop in Juniperus communis, its carbohydrate composition and the response to deposition of conspecific pollen, foreign pollen and other particulate material, in an attempt to clarify the mechanism of pollination drop retraction. Method Branches with female cones close to pollination drop secretion were collected. On the first day of pollination drop exposure, an eyelash mounted on a wooden stick with paraffin was used to collect pollen or silica gel particles, which were then deposited by contact with the drop. Volume changes in pollination drops were measured by using a stereomicroscope with a micrometer eyepiece 3 h after deposition. The volume of non-pollinated control drops was also recorded. On the first day of secretion, drops were also collected for sugar analysis by high-performance liquid chromatography. Key Results The pollination drop persisted for about 12 d if not pollinated, and formed again after removal for up to four consecutive days. After pollination with viable conspecific pollen, the drop retracted quickly and did not form again. Partial withdrawal occurred after deposition of other biological and non-biological material. Fructose was the dominant sugar; glucose was also present but at a much lower percentage. Conclusions Sugar analysis confirmed the general trend of fructose dominance in gymnosperm pollination drops. Complete pollination drop withdrawal appears to be triggered by a biochemical mechanism resulting from interaction between pollen and drop constituents. The results of particle deposition suggest the existence of a non-specific, particle-size-dependent mechanism that induces partial pollination drop withdrawal. These results suggest that the non-specific response may decrease the probability of pollen landing on the drop, reducing pollination efficiency. PMID:17942592

  13. Effects of surface-conditioning methods on shear bond strength of brackets bonded to different all-ceramic materials.

    PubMed

    Saraç, Y Şinasi; Külünk, Tolga; Elekdağ-Türk, Selma; Saraç, Duygu; Türk, Tamer

    2011-12-01

    The aims of this study were to investigate the effects of two surface-conditioning methods on the shear bond strength (SBS) of metal brackets bonded to three different all-ceramic materials, and to evaluate the mode of failure after debonding. Twenty feldspathic, 20 fluoro-apatite, and 20 leucite-reinforced ceramic specimens were examined following two surface-conditioning methods: air-particle abrasion (APA) with 25 μm Al(2)O(3) and silica coating with 30 μm Al(2)O(3) particles modified by silica. After silane application, metal brackets were bonded with light cure composite and then stored in distilled water for 1 week and thermocycled (×1000 at 5-55°C for 30 seconds). The SBS of the brackets was measured on a universal testing machine. The ceramic surfaces were examined with a stereomicroscope to determine the amount of composite resin remaining using the adhesive remnant index. Two-way analysis of variance, Tukey's multiple comparison test, and Weibull analysis were used for evaluation of SBS. The lowest SBS was with APA for the fluoro-apatite ceramic (11.82 MPa), which was not significantly different from APA for the feldspathic ceramic (13.58 MPa). The SBS for the fluoro-apatite ceramic was significantly lower than that of leucite-reinforced ceramic with APA (14.82 MPa). The highest SBS value was obtained with silica coating of the leucite-reinforced ceramic (24.17 MPa), but this was not significantly different from the SBS for feldspathic and fluoro-apatite ceramic (23.51 and 22.18 MPa, respectively). The SBS values with silica coating showed significant differences from those of APA. For all samples, the adhesive failures were between the ceramic and composite resin. No ceramic fractures or cracks were observed. Chairside tribochemical silica coating significantly increased the mean bond strength values.

  14. IVHS Countermeasures for Rear-End Collisions, Task 1; Vol. II: Statistical Analysis

    DOT National Transportation Integrated Search

    1994-02-25

    This report is from the NHTSA sponsored program, "IVHS Countermeasures for Rear-End Collisions". This Volume, Volume II, Statistical Analysis, presents the statistical analysis of rear-end collision accident data that characterizes the accidents with...

  15. Notes on numerical reliability of several statistical analysis programs

    USGS Publications Warehouse

    Landwehr, J.M.; Tasker, Gary D.

    1999-01-01

    This report presents a benchmark analysis of several statistical analysis programs currently in use in the USGS. The benchmark consists of a comparison between the values provided by a statistical analysis program for variables in the reference data set ANASTY and their known or calculated theoretical values. The ANASTY data set is an amendment of the Wilkinson NASTY data set that has been used in the statistical literature to assess the reliability (computational correctness) of calculated analytical results.

  16. Computer Automated Ultrasonic Inspection System

    DTIC Science & Technology

    1985-02-06

    Reports 74 3.1.4 Statistical Analysis Capability 74 3.2 Nondestructive Evaluation Terminal Hardware 76 3.3 Nondestructive Evaluation Terminal Vendor...3.4.2.6 Create a Hold Tape 103 vi TABLE OF CONTENTS SECTION PAGE 3.4.3 System Status 104 3.4.4 Statistical Analysis 105 3.4.4.1 Statistical Analysis...Data Extraction 105 3.4.4.2 Statistical Analysis Report and Display Generation 106 3.4.5 Quality Assurance Reports 106 3.4.6 Nondestructive Inspection

  17. Computers as an Instrument for Data Analysis. Technical Report No. 11.

    ERIC Educational Resources Information Center

    Muller, Mervin E.

    A review of statistical data analysis involving computers as a multi-dimensional problem provides the perspective for consideration of the use of computers in statistical analysis and the problems associated with large data files. An overall description of STATJOB, a particular system for doing statistical data analysis on a digital computer,…

  18. Shock and Vibration Symposium (59th) Held in Albuquerque, New Mexico on 18-20 October 1988. Volume 1

    DTIC Science & Technology

    1988-10-01

    Partial contents: The Quest for Omega = sq root(K/M) -- Notes on the development of vibration analysis; An overview of Statistical Energy analysis ; Its...and inplane vibration transmission in statistical energy analysis ; Vibroacoustic response using the finite element method and statistical energy analysis ; Helium

  19. A workflow for improving estimates of microplastic contamination in marine waters: A case study from North-Western Australia.

    PubMed

    Kroon, Frederieke; Motti, Cherie; Talbot, Sam; Sobral, Paula; Puotinen, Marji

    2018-07-01

    Plastic pollution is ubiquitous throughout the marine environment, with microplastic (i.e. <5 mm) contamination a global issue of emerging concern. The lack of universally accepted methods for quantifying microplastic contamination, including consistent application of microscopy, photography, an spectroscopy and photography, may result in unrealistic contamination estimates. Here, we present and apply an analysis workflow tailored to quantifying microplastic contamination in marine waters, incorporating stereomicroscopic visual sorting, microscopic photography and attenuated total reflectance (ATR) Fourier transform infrared (FTIR) spectroscopy. The workflow outlines step-by-step processing and associated decision making, thereby reducing bias in plastic identification and improving confidence in contamination estimates. Specific processing steps include (i) the use of a commercial algorithm-based comparison of particle spectra against an extensive commercially curated spectral library, followed by spectral interpretation to establish the chemical composition, (ii) a comparison against a customised contaminant spectral library to eliminate procedural contaminants, and (iii) final assignment of particles as either natural- or anthropogenic-derived materials, based on chemical type, a compare analysis of each particle against other particle spectra, and physical characteristics of particles. Applying this workflow to 54 tow samples collected in marine waters of North-Western Australia visually identified 248 potential anthropogenic particles. Subsequent ATR-FTIR spectroscopy, chemical assignment and visual re-inspection of photographs established 144 (58%) particles to be of anthropogenic origin. Of the original 248 particles, 97 (39%) were ultimately confirmed to be plastics, with 85 of these (34%) classified as microplastics, demonstrating that over 60% of particles may be misidentified as plastics if visual identification is not complemented by spectroscopy. Combined, this tailored analysis workflow outlines a consistent and sequential process to quantify contamination by microplastics and other anthropogenic microparticles in marine waters. Importantly, its application will contribute to more realistic estimates of microplastic contamination in marine waters, informing both ecological risk assessments and experimental concentrations in effect studies. Copyright © 2018 Australian Institute of Marine Science. Published by Elsevier Ltd.. All rights reserved.

  20. Eagle Plus Air Superiority into the 21st Century

    DTIC Science & Technology

    1996-04-01

    18 Data Collection Method ....................................................................................... 18 Statistical Trend Analysis...19 Statistical Readiness Analysis.................................................................................... 20 Aging Aircraft...generated by Mr. Jeff Hill served as the foundation of our statistical analysis. Special thanks go out to Mrs. Betsy Mullis, LFLL branch chief, and to

  1. The Content of Statistical Requirements for Authors in Biomedical Research Journals

    PubMed Central

    Liu, Tian-Yi; Cai, Si-Yu; Nie, Xiao-Lu; Lyu, Ya-Qi; Peng, Xiao-Xia; Feng, Guo-Shuang

    2016-01-01

    Background: Robust statistical designing, sound statistical analysis, and standardized presentation are important to enhance the quality and transparency of biomedical research. This systematic review was conducted to summarize the statistical reporting requirements introduced by biomedical research journals with an impact factor of 10 or above so that researchers are able to give statistical issues’ serious considerations not only at the stage of data analysis but also at the stage of methodological design. Methods: Detailed statistical instructions for authors were downloaded from the homepage of each of the included journals or obtained from the editors directly via email. Then, we described the types and numbers of statistical guidelines introduced by different press groups. Items of statistical reporting guideline as well as particular requirements were summarized in frequency, which were grouped into design, method of analysis, and presentation, respectively. Finally, updated statistical guidelines and particular requirements for improvement were summed up. Results: Totally, 21 of 23 press groups introduced at least one statistical guideline. More than half of press groups can update their statistical instruction for authors gradually relative to issues of new statistical reporting guidelines. In addition, 16 press groups, covering 44 journals, address particular statistical requirements. The most of the particular requirements focused on the performance of statistical analysis and transparency in statistical reporting, including “address issues relevant to research design, including participant flow diagram, eligibility criteria, and sample size estimation,” and “statistical methods and the reasons.” Conclusions: Statistical requirements for authors are becoming increasingly perfected. Statistical requirements for authors remind researchers that they should make sufficient consideration not only in regards to statistical methods during the research design, but also standardized statistical reporting, which would be beneficial in providing stronger evidence and making a greater critical appraisal of evidence more accessible. PMID:27748343

  2. The Content of Statistical Requirements for Authors in Biomedical Research Journals.

    PubMed

    Liu, Tian-Yi; Cai, Si-Yu; Nie, Xiao-Lu; Lyu, Ya-Qi; Peng, Xiao-Xia; Feng, Guo-Shuang

    2016-10-20

    Robust statistical designing, sound statistical analysis, and standardized presentation are important to enhance the quality and transparency of biomedical research. This systematic review was conducted to summarize the statistical reporting requirements introduced by biomedical research journals with an impact factor of 10 or above so that researchers are able to give statistical issues' serious considerations not only at the stage of data analysis but also at the stage of methodological design. Detailed statistical instructions for authors were downloaded from the homepage of each of the included journals or obtained from the editors directly via email. Then, we described the types and numbers of statistical guidelines introduced by different press groups. Items of statistical reporting guideline as well as particular requirements were summarized in frequency, which were grouped into design, method of analysis, and presentation, respectively. Finally, updated statistical guidelines and particular requirements for improvement were summed up. Totally, 21 of 23 press groups introduced at least one statistical guideline. More than half of press groups can update their statistical instruction for authors gradually relative to issues of new statistical reporting guidelines. In addition, 16 press groups, covering 44 journals, address particular statistical requirements. The most of the particular requirements focused on the performance of statistical analysis and transparency in statistical reporting, including "address issues relevant to research design, including participant flow diagram, eligibility criteria, and sample size estimation," and "statistical methods and the reasons." Statistical requirements for authors are becoming increasingly perfected. Statistical requirements for authors remind researchers that they should make sufficient consideration not only in regards to statistical methods during the research design, but also standardized statistical reporting, which would be beneficial in providing stronger evidence and making a greater critical appraisal of evidence more accessible.

  3. Application of Statistics in Engineering Technology Programs

    ERIC Educational Resources Information Center

    Zhan, Wei; Fink, Rainer; Fang, Alex

    2010-01-01

    Statistics is a critical tool for robustness analysis, measurement system error analysis, test data analysis, probabilistic risk assessment, and many other fields in the engineering world. Traditionally, however, statistics is not extensively used in undergraduate engineering technology (ET) programs, resulting in a major disconnect from industry…

  4. Tri-Center Analysis: Determining Measures of Trichotomous Central Tendency for the Parametric Analysis of Tri-Squared Test Results

    ERIC Educational Resources Information Center

    Osler, James Edward

    2014-01-01

    This monograph provides an epistemological rational for the design of a novel post hoc statistical measure called "Tri-Center Analysis". This new statistic is designed to analyze the post hoc outcomes of the Tri-Squared Test. In Tri-Center Analysis trichotomous parametric inferential parametric statistical measures are calculated from…

  5. Shell color polymorphism in the marine gastropod Mitrella fusiformis

    NASA Astrophysics Data System (ADS)

    Jones, M. J.

    2016-02-01

    Gastropod mollusks are extremely important in marine ecosystems as predators and prey, especially in coral reefs. It is important to understand where and how these benthic organisms interact with their communities and with the physical aspects of their ecosystems. Our project is to study polymorphism among shallow water columbellids, a common and diverse family of marine neogastropod snail. Columbellids are small (most are less than 10 mm in length) and can be very common epibenthic carnivores in shallow marine systems. A number of nearshore species in this group are polymorphic for shell color and pattern, a factor that may correlate to their individual survival by making them more or less visible to predators and prey. Our objective is to investigate correlations between polymorphism, environment and sex in common local epibenthic marine gastropods. This study will focus on Mitrella fusiformis (Pease, 1868), one of the most common local columbellid species. Last year, we determined that there were trends for different morphs on the leeward and windward sides of Hawaii Island but our sample size was not large enough to show statistical significance. Thus, this year our project focuses on increasing sample size to better elucidate trends. In addition, further emphasis will be placed on collecting environmental data with the hopes of correlating environmental factors with certain polymorphisms. Common environmental factors to be recorded are salinity, temperature, food source and habitat. To study these organisms, we will make collections in several locations around the Island of Hawai`i, where they are found typically in 1m depth or less. Individual adult animals will be sexed, measured, and their shell color and pattern documented photographically using a dissecting stereomicroscope with camera. Most animals will be returned alive to their original habitat after data are collected. The resulting data set will allow us to investigate correlations between shell color and pattern, and factors including sex, substrate habitat, salinity, and location. The hope is to gain more insight into how these organisms interact with their habitats in our Hawaiian waters.

  6. Efficacy of Different Methods for Removing Root Canal Filling Material in Retreatment - An In-vitro Study.

    PubMed

    Kasam, Swetha; Mariswamy, Annapoorna Ballagere

    2016-06-01

    Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm(2). Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe's post hoc test through SPSS for windows (v 16.0). The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. All techniques retained guttapercha/sealer remnants within the root canal. The ultrasonic retreatment tip proved to be an efficient method of removing obturated material. It was fastest with least apical debris extrusion.

  7. Efficacy of Different Methods for Removing Root Canal Filling Material in Retreatment - An In-vitro Study

    PubMed Central

    Mariswamy, Annapoorna Ballagere

    2016-01-01

    Introduction Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. Aim To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Materials and Methods Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm2. Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe’s post hoc test through SPSS for windows (v 16.0). Results The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. Conclusion All techniques retained guttapercha/sealer remnants within the root canal. The ultrasonic retreatment tip proved to be an efficient method of removing obturated material. It was fastest with least apical debris extrusion. PMID:27504397

  8. Microshear bond strength of self-etching systems associated with a hydrophobic resin layer.

    PubMed

    De Vito Moraes, André Guaraci; Francci, Carlos; Carvalho, Ceci Nunes; Soares, Silvio Peixoto; Braga, Roberto Ruggiero

    2011-08-01

    To evaluate in vitro the microshear bond strength of adhesive systems applied to dentin according to manufacturers' instructions, associated or not with a hydrophobic layer of unfilled resin. Six self-etching adhesives (Clearfil SE Bond, Kuraray Medical; AdheSE, Ivoclar Vivadent; Xeno III, Dentsply; I Bond, Heraeus-Kulzer; Bond Force, Tokuyama; Futurabond DC, Voco) were tested. The labial dentin of sixty bovine incisors was exposed, and the teeth were divided into two groups according to the application or not of an extra hydrophobic resin layer (Scotchbond Multi Purpose Plus, bottle 3). Six composite cylinders (Filtek Z250, 3M ESPE) were built up on each treated surface. Specimens were stored in distilled water at 37ºC for 24 h and then subjected to the microshear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. Microshear bond strength values were analyzed by 2-way ANOVA and Tukey's post-hoc test. Failure mode was determined using a stereomicroscope under 20X magnification. The application of the hydrophobic resin layer did not affect bond strength, except for AdheSE. However, the bond strengths with the hydrophobic layer were similar among the six tested systems (Clearfil: 17.1 ± 7.9; AdheSE: 14.5 ± 7.1; Xeno lll: 12.8 ± 7.7; I Bond: 9.5 ± 5.8; Bond Force: 17.5 ± 4.1; Futurabond: 7.7 ± 2.3). When used as recommended by the manufacturers, Bond Force presented statistically higher bond strength than AdheSE and I Bond (p < 0.05) (Clearfil 10.4 ± 4.9; AdheSE 1.6 ± 1.6; Xeno lll: 9.0 ± 3.8; I Bond: 3.0 ± 1.5; Bond Force: 14 ± 3.9; Futurabond: 8.8 ± 3.8). Failure mode was predominantly adhesive. The bond strength of the self-etching systems tested was not significantly affected by the application of a hydrophobic layer, but a significant improvement was observed in AdheSE.

  9. Sealing ability and bond strength of four contemporary adhesives to enamel and to dentine.

    PubMed

    Atash, R; Vanden Abbeele, A

    2005-12-01

    To compare the shear bond strength and microleakage of four adhesive systems to the enamel and dentine of primary bovine teeth. 120 bovine primary mandibular incisors were collected and stored in an aqueous 1% chloramine solution at room temperature for no longer than 3 months after extraction (80 for shear bond testing and 40 for microleakage evaluation). The adhesives tested were Clearfil SE bond (SE), Adper Prompt L Pop (LP), Xeno III (XE), and Prime and Bond NT (PB). For shear bond strength testing the specimens were wet ground to 600 grit SiC paper to expose a flat enamel or dentine surface. After bonding and restoration with Dyract AP (DAP), the teeth were subjected to shear stress using a universal testing machine. For microleakage evaluation, facial class V cavities were prepared half in enamel and half in cementum. All cavities were restored with DAP. After thermocycling and immersion in 2% methylene blue, the dye penetration was evaluated under a stereomicroscope. All data were analysed by Chi-square tests or Fisher's tests when adapted in order to determine the significant differences between groups. Results were considered as significant for p < 0.05. Results were analysed with an ANOVA test and a Bonferroni's multiple comparison. The level of significance was p < 0.05. Shear bond strength values (MPa,) ranged from: on enamel 11.06 to 5.34, in decreasing order SE, LP, XE and PB and on dentine 10.47 to 4.74, in decreasing order SE, XE, LP and PB. Differences in bond strengths between the four systems on enamel and dentine were all statistically significant, excepted for XE vs LP (shear bond at dentine). No significant differences were recorded in the microleakage degree between the four adhesive systems on enamel and on dentine (p > 0.0.5). The highest shear bond strength was achieved by Clearfil SE bond and the lowest by Prime and Bond NT. There was no significant difference concerning the sealing ability of the four adhesive systems.

  10. The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations: A scanning electron microscopy evaluation

    PubMed Central

    Mirzaie, Mansoreh; Yasini, Esmail; Kermanshah, Hamid; Omidi, Baharan Ranjbar

    2014-01-01

    Background: Microleakage is one of the challenging concerns in direct filling restorations. Understanding of its related factors is important in clinical practice. The aim of this study was scanning electron microscopy (SEM) evaluation of marginal integrity in three types of tooth-colored restorative materials in class V cavity preparations and the effect of load cycling and polishing time on the microleakage. Materials and Methods: In this in vitro experimental study, class V cavity preparations were prepared on the buccal and lingual surfaces of 60 bovine incisors. The specimens were divided into three groups each containing 20 teeth: group 1: Filtek Z350, Group 2: Fuji IX/G Coat Plus, Group 3: Fuji II LC/GC varnish. In each group, 2 subgroups (n = 20) were established based on finishing time (immediate or delayed by 24 h). All specimens were thermocycled (×2,000, 5-50°C). In each sub groups, half of the teeth were load cycled. Epoxy resin replicas of 24 specimens were evaluated under field emission-SEM and interfacial gaps were measured. All teeth were then immersed in 0.5% basic fuchsin dye for 24 h, sectioned and observed under stereomicroscope. Data were analyzed with Kruskal-Wallis’ test and Mann-Whitney U test and a comparison between incisal and cervical microleakage was made with Wilcoxon test. P < 0.05 was considered as significant. Results: Load cycling and filling material had a significant effect on microleakage, but polishing time did not. Cervical microleakage in Z350/load cycle/immediate polish and Fuji IX/load cycle/immediate or delayed polish and Fuji IX/no load cycle/immediate polish were significantly higher than incisal microleakage. Conclusion: It was concluded that the cervical sealing ability of Fuji IX under load cycling was better than Fuji II LC. Under load cycling and immediate polishing Z350 showed better marginal integrity than both Fuji II LC and Fuji IX. The immediate polishing didn’t cause a statistically significant increase in microleakage of evaluated tooth-colored class V restorations. PMID:24688568

  11. The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations: A scanning electron microscopy evaluation.

    PubMed

    Mirzaie, Mansoreh; Yasini, Esmail; Kermanshah, Hamid; Omidi, Baharan Ranjbar

    2014-01-01

    Microleakage is one of the challenging concerns in direct filling restorations. Understanding of its related factors is important in clinical practice. The aim of this study was scanning electron microscopy (SEM) evaluation of marginal integrity in three types of tooth-colored restorative materials in class V cavity preparations and the effect of load cycling and polishing time on the microleakage. In this in vitro experimental study, class V cavity preparations were prepared on the buccal and lingual surfaces of 60 bovine incisors. The specimens were divided into three groups each containing 20 teeth: group 1: Filtek Z350, Group 2: Fuji IX/G Coat Plus, Group 3: Fuji II LC/GC varnish. In each group, 2 subgroups (n = 20) were established based on finishing time (immediate or delayed by 24 h). All specimens were thermocycled (×2,000, 5-50°C). In each sub groups, half of the teeth were load cycled. Epoxy resin replicas of 24 specimens were evaluated under field emission-SEM and interfacial gaps were measured. All teeth were then immersed in 0.5% basic fuchsin dye for 24 h, sectioned and observed under stereomicroscope. Data were analyzed with Kruskal-Wallis' test and Mann-Whitney U test and a comparison between incisal and cervical microleakage was made with Wilcoxon test. P < 0.05 was considered as significant. Load cycling and filling material had a significant effect on microleakage, but polishing time did not. Cervical microleakage in Z350/load cycle/immediate polish and Fuji IX/load cycle/immediate or delayed polish and Fuji IX/no load cycle/immediate polish were significantly higher than incisal microleakage. It was concluded that the cervical sealing ability of Fuji IX under load cycling was better than Fuji II LC. Under load cycling and immediate polishing Z350 showed better marginal integrity than both Fuji II LC and Fuji IX. The immediate polishing didn't cause a statistically significant increase in microleakage of evaluated tooth-colored class V restorations.

  12. Comparative efficacy of Er,Cr:YSGG and Er:YAG lasers for etching of composite for orthodontic bracket bonding.

    PubMed

    Mirhashemi, Amir Hossein; Chiniforush, Nasim; Sharifi, Nastaran; Hosseini, Amir Mehdi

    2018-05-01

    Several techniques have been proposed to obtain a durable bond, and the efficacy of these techniques is assessed by measuring parameters such as bond strength. Laser has provided a bond strength as high as that of acid etching in vitro and has simpler use with shorter clinical time compared to acid etching. This study aimed to compare the efficacy of Er:YAG and Er,Cr:YSGG lasers for etching and bonding of composite to orthodontic brackets. No previous study has evaluated the effect of these particular types of laser. A total of 70 composite blocks were randomly divided into five groups (n = 14): group 1, etching with phosphoric acid for 20 s; group 2, Er:YAG laser irradiation with 2 W power for 10 s; group 3, Er:YAG laser with 3 W power for 10 s; group 4, Er,Cr:YSGG laser with 2 W power for 10 s; group 5, Er,Cr:YSGG laser with 3 W power for 10 s. Metal brackets were then bonded to composites, and after 5000 thermal cycles, they were subjected to shear bond strength test in a universal testing machine after 24 h of water storage. One sample of each group was evaluated under a scanning electron microscope (SEM) to assess changes in composite surface after etching. The adhesive remnant index (ARI) was calculated under a stereomicroscope. Data were statistically analyzed. The mean and standard deviation of shear bond strength were 18.65 ± 3.36, 19.68 ± 5.34, 21.31 ± 4.03, 17.38 ± 6.94, and 16.45 ± 4.26 MPa in groups 1-5, respectively. The ARI scores showed that the bond failure mode in all groups was mainly mixed. The groups were not significantly different in terms of shear bond strength. Er:YAG and Er,Cr:YSGG lasers with the mentioned parameters yield optimal shear bond strength and can be used as an alternative to acid etching for bracket bond to composite.

  13. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study.

    PubMed

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann-Whitney U-test, Kruskal-Wallis H-test and the results were statistically significant P < 0.05 the power of study - 80%. Marginal leakage was significant in both provisional crowns cemented with three different luting cements along the axial walls of teeth (P < 0.05) confidence interval - 95%. The temporary cements with eugenol showed more microleakage than those without eugenol. SC-10 crowns showed more microleakage compared to Protemp 4 crowns. SC-10 crowns cemented with Kalzinol showed maximum microleakage and Protemp 4 crowns cemented with HY bond showed least microleakage.

  14. Digital volume tomography in the diagnosis of peri-implant defects: an in vitro study on native pig mandibles.

    PubMed

    Mengel, Reiner; Kruse, Björn; Flores-de-Jacoby, Lavin

    2006-07-01

    The aim of this study of native pig mandibles was to investigate the accuracy and quality of the representation of peri-implant defects by intraoral radiography (IR), panoramic radiography (PR), computer tomography (CT), and digital volume tomography (DVT). The examination was carried out on 19 native pig mandibles. In the toothless sections of the mandibles, one or two implants were inserted. Following the standardized preparation of peri-implant defects (11 each of dehiscences, fenestrations, and 2- to 3-walled intrabony defects), IR, PR, CT, and DVT were performed. The peri-implant defects were measured using appropriate software on the digitized IR and PR image programs. As a control method, the peri-implant bone defects were measured directly using a reflecting stereomicroscope with measuring ocular. The statistical comparison between the measurements of the radiographic scans and those of the direct readings of the peri-implant defects was performed with Pearson's correlation coefficient. The quality of the radiographic scans was determined through the subjective perception and detectability of the peri-implant defects by five independent observers. In the DVT and CT scans, it was possible to measure all the bone defects in three planes. Comparison with the direct peri-implant defect measurements yielded a mean deviation of 0.17+/-0.11 mm for the DVT scans and 0.18+/-0.12 mm for the CT scans. On the IR and PR images, the defects could be detected only in the mesio-distal and cranio-caudal planes. In comparison with the direct measurements of the peri-implant defects, the IR images revealed a mean deviation of 0.34+/-0.30 mm, and the PR images revealed a mean deviation of 0.41+/-0.35 mm. The quality rating of the radiographic images was highest for the DVT scans. Overall, the CT and DVT scans displayed only a slight deviation in the extent of the peri-implant defects. Both radiographic imaging techniques permitted imaging of peri-implant defects in three planes, true to scale, and without overlay or distortion. The DVT scans showed the best imaging quality.

  15. Metalworking defects in surgery screws as a possible cause of post-surgical infections

    NASA Astrophysics Data System (ADS)

    Spector, Mario; Peretti, Leandro E.; Romero, Gustavo

    2016-04-01

    In the first phase of this work, surface defects (metalworking) in stainless steel implantable prostheses and their possible relation to infections that can be generated after surgery was studied. In a second phase, the results obtained in the aforementioned stage were applied to knee cruciate ligaments surgery screws, considering the fact that a substantial number of Mucormycetes infections have been reported after arthroscopic surgery in Argentina since the year 2005. Two types of screws, transverse and interference screws, were analyzed. The Allen heads presented defects such as burrs and metalworking bending as a result of the machining process. These defects allow the accumulation of machining oil, which could be contaminated with fungal spores. When this is the case, the gaseous sterilization by ethylene oxide may be jeopardized. Cortical screws were also analyzed and were found to present serious metalworking defects inside their heads. To reduce the risk of infection in surgery, the use of screws with metalworking defects on the outer surface, analyzed with stereomicroscope and considering the inside part of the Allen as an outer surface, should be avoided altogether.

  16. The use of porcine corrosion casts for teaching human anatomy.

    PubMed

    Eberlova, Lada; Liska, Vaclav; Mirka, Hynek; Tonar, Zbynek; Haviar, Stanislav; Svoboda, Milos; Benes, Jan; Palek, Richard; Emingr, Michal; Rosendorf, Jachym; Mik, Patrik; Leupen, Sarah; Lametschwandtner, Alois

    2017-09-01

    In teaching and learning human anatomy, anatomical autopsy and prosected specimens have always been indispensable. However, alternative methods must often be used to demonstrate particularly delicate structures. Corrosion casting of porcine organs with Biodur E20 ® Plus is valuable for teaching and learning both gross anatomy and, uniquely, the micromorphology of cardiovascular, respiratory, digestive, and urogenital systems. Assessments of casts with a stereomicroscope and/or scanning electron microscope as well as highlighting cast structures using color coding help students to better understand how the structures that they have observed as two-dimensional images actually exist in three dimensions, and students found using the casts to be highly effective in their learning. Reconstructions of cast hollow structures from (micro-)computed tomography scans and videos facilitate detailed analyses of branching patterns and spatial arrangements in cast structures, aid in the understanding of clinically relevant structures and provide innovative visual aids. The casting protocol and teaching manual we offer can be adjusted to different technical capabilities and might also be found useful for veterinary or other biological science classes. Copyright © 2017 Elsevier GmbH. All rights reserved.

  17. Generic delimitation between Fragariocoptes and Sierraphytoptus (Acari: Eriophyoidea: Phytoptidae) and a supplementary description of Fragariocoptes gansuensis with remarks on searching for mummified eriophyoid mites in herbaria under UV light.

    PubMed

    Chetverikov, Philipp E

    2016-01-15

    Generic concepts of Fragariocoptes Roivainen, 1951 and Sierraphytoptus Keifer, 1939 are discussed and the correct delimitation between these two genera is given. A supplementary description of Fragariocoptes gansuensis Wei, Chen & Luo, 2005 is included based on fresh specimens from Astrakhan, Russia and dried mummies found in old herbaria collected in 1919 from southern European Russia of the cinquefoil, Potentilla bifurca L. (Rosaceae) with pathological stem proliferation. The male of this species is described for the first time. The cuticle of eriophyoid mummies emitted a faint glow under UV light wavelength equal to 365 nm of a common UV Light-Emitting diode (LED) lamp showing that this characteristic could be useful for quickly detecting eriophyoids in old herbaria which would otherwise be almost indistinguishable against the background under the regular white light source of a stereomicroscope. This was only possible for plant material stored in appropriate conditions enabling the autofluorescent signal of the dried mite cuticle to remain strong enough for observation.

  18. Effect of different evaporation periods on microtensile bond strength of an acetone-based adhesive to dentin.

    PubMed

    Davari, Abdolrahim; Mousvinasab, Majid; Kazemi, Alireza Danesh; Rouzbeh, Reza

    2013-01-01

    Solvent content of a contemporary dental adhesive affect the bonding process, especially in the case of acetone based adhesives. The aim of this study was to evaluate the effect of different air-drying periods on microtensile bond strength (MTBS) of a total-etch adhesive to dentin. Prime & Bond NT (Dentsply-USA) was used with different air-drying periods (0, 2, 5, 10, 30sec) for bonding a composite resin to prepared dentin. The specimens were then subjected to a tensile force until fracture and the MTBSs of the samples were recorded. Failure modes of the fractured samples were also determined using stereomicroscope and scanning electron microscopy. Data were analyzed using ANOVA and Bonferroni tests (P = 0.05). With increasing the air-drying periods, the MTBSs were increased until the 5 second air-blowing; after that, with increasing the air-drying periods, the MTBSs decreased. Both, the most complicated failure and the strongest bond were seen in the 5 sec air-drying group. There is an optimum air-drying time for acetone based adhesives which results in the strongest bond to dentin.

  19. The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals.

    PubMed

    Yoshimine, Y; Ono, M; Akamine, A

    2005-05-01

    The purpose of this study was to compare the shaping effects of three nickel-titanium rotary instruments, ProTaper, K3, and RaCe, with emphasis on canal transportation. Simulated canals with an S-shaped curvature in clear resin blocks were prepared with a torque-control, low-speed engine. Canals were prepared using the crown-down technique to the size of #30. Canal aberrations were assessed by comparing the pre- and postinstrumentation images under a stereomicroscope. ProTaper instruments caused greater widening of canals compared to K3 or RaCe. Furthermore, ProTaper files showed a tendency to ledge or zip formation at the end-point of preparation. These canal aberrations may be caused by ProTaper finishing files, which appear to be less flexible than other files of the same tip-size, because of their greater taper-size. These results suggest that nickel-titanium file systems including less tapered, more flexible instruments, like K3 and RaCe should be used in the apical preparation of canals with a complicated curvature.

  20. Simulation and evaluation of rupturable coated capsules by finite element method.

    PubMed

    Yang, Yan; Fang, Jie; Shen, Lian; Shan, Weiguang

    2017-03-15

    The objective of this study was to simulate and evaluate the burst behavior of rupturable coated capsules by finite element method (FEM). Film and coated capsules were prepared by dip-coating method and their dimensions were determined by stereomicroscope. Mechanical properties of the film were measured by tensile test and used as material properties of FEM models. Swelling pressure was determined by restrained expansion method and applied to the internal surface of FEM models. Water uptake of coated capsules was determined to study the formation of internal pressure. Burst test and in vitro dissolution was used to verify the FEM models, which were used to study and predict the coating burst behavior. Simulated results of coating burst behavior were well agreed with the experiment results. Swelling pressure, material properties and dimensions of coating had influence on the maximum stress. Burst pressure and critical L-HPC content were calculated for burst prediction and formulation optimization. FEM simulation was a feasible way to simulate and evaluate the burst behavior of coated capsules. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Ex vivo pharmacology of surgical samples of the uterosacral ligament. Part I: Effects of carbachol and oxytocin on smooth muscle.

    PubMed

    Drews, Ulrich; Renz, Matthias; Busch, Christian; Reisenauer, Christl

    2012-11-01

    In a previous study we observed impaired smooth muscle in the uterosacral ligament (USL) of patients with pelvic organ prolapse. The aims of the study were to describe the method of the novel microperfusion system and to determine normal function and pharmacology of smooth muscle in the USL. Samples from the USL were obtained during hysterectomy for benign reasons. Small stretches of connective tissue were mounted in a perfusion chamber under the stereomicroscope. Isotonic contractions of smooth muscle were monitored by digital time-lapse video and quantified by image processing. Constant perfusion with carbachol elicited tonic and pulse stimulation with carbachol and oxytocin rhythmic contractions of smooth muscle in the ground reticulum. Under constant perfusion with relaxin the tonic contraction after carbachol was abolished. With the novel microperfusion system, isotonic contractions of smooth muscle in the USL can be recorded and quantified in the tissue microenvironment on the microscopic level. The USL smooth muscle is cholinergic, stimulated by oxytocin and modulated by relaxin. Copyright © 2012 Wiley Periodicals, Inc.

  2. Short Article The Use of Mercury against Pediculosis in the Renaissance: The Case of Ferdinand II of Aragon, King of Naples, 1467–96

    PubMed Central

    FORNACIARI, GINO; MARINOZZI, SILVIA; GAZZANIGA, VALENTINA; GIUFFRA, VALENTINA; PICCHI, MALAYKA SAMANTHA; GIUSIANI, MARIO; MASETTI, MASSIMO

    2011-01-01

    The hair samples of Ferdinand II of Aragon (1467–1496), King of Naples, whose mummy is preserved in the Basilica of San Domenico Maggiore in Naples, showed a high content of mercury, with a value of 827ppm. Furthermore, examination using a stereomicroscope and a scanning electron microscope (SEM) of head and pubic hairs of Ferdinand II, revealed a lice infestation. The reasons for the massive presence of the mercury in the king's hair are discussed and contemporary literature regarding the use of this metal in medical therapies and in cosmetic practices is analysed. As a result, the high value of mercury in the hair of Ferdinand II can be attributed to antipediculosis therapy, applied as a topic medicament. This case represents an important finding for the history of medicine, because demonstrates that in the Renaissance mercury was applied locally not only to treat syphilis, as well attested by direct and indirect sources, but also to prevent or eliminate lice infestation. PMID:23752867

  3. Interspecific interaction between Telenomus remus (Hymenoptera: Platygastridae) and Trichogramma pretiosum (Hymenoptera: Trichogrammatidae) on Spodoptera frugiperda (Lepidoptera: Noctuidae) eggs.

    PubMed

    Carneiro, Tatiana R; Fernandes, Odair A

    2012-12-01

    This work aims to evaluate the interspecific interaction between Trichogramma pretiosum and Telenomus remus, two biological control agents of fall armyworm (Spodoptera frugiperda) eggs. Eggs of Spodoptera frugiperda previously parasitized by Telenomus remus were offered to Trichogramma pretiosum, and those parasitized by Trichogramma pretiosum were offered to Telenomus remus. The previously parasitized eggs were tested at different embryonic development stages for each parasitoid. In addition, to evaluate the competition between species, Spodoptera frugiperda eggs were offered to the parasitoids simultaneously. The behavior of the insects was recorded under a stereomicroscope. When Spodoptera frugiperda eggs were previously exposed to either parasitoid, there was no emergence of the other parasitoid. When the Telenomus remus and Trichogramma pretiosum females were placed together with Spodoptera frugiperda eggs, Telenomus remus had a greater parasitism rate. Except searching time, all Trichogramma pretiosum behaviors took a longer time than Telenomus remus behaviors. Thus, despite belonging to different families, each of these parasitoids is able to recognize host eggs previously parasitized by the other. So, this suggests that the recognition mechanism involved is not exclusively specific.

  4. Teaching statistics in biology: using inquiry-based learning to strengthen understanding of statistical analysis in biology laboratory courses.

    PubMed

    Metz, Anneke M

    2008-01-01

    There is an increasing need for students in the biological sciences to build a strong foundation in quantitative approaches to data analyses. Although most science, engineering, and math field majors are required to take at least one statistics course, statistical analysis is poorly integrated into undergraduate biology course work, particularly at the lower-division level. Elements of statistics were incorporated into an introductory biology course, including a review of statistics concepts and opportunity for students to perform statistical analysis in a biological context. Learning gains were measured with an 11-item statistics learning survey instrument developed for the course. Students showed a statistically significant 25% (p < 0.005) increase in statistics knowledge after completing introductory biology. Students improved their scores on the survey after completing introductory biology, even if they had previously completed an introductory statistics course (9%, improvement p < 0.005). Students retested 1 yr after completing introductory biology showed no loss of their statistics knowledge as measured by this instrument, suggesting that the use of statistics in biology course work may aid long-term retention of statistics knowledge. No statistically significant differences in learning were detected between male and female students in the study.

  5. Teaching Principles of Linkage and Gene Mapping with the Tomato.

    ERIC Educational Resources Information Center

    Hawk, James A.; And Others

    1980-01-01

    A three-point linkage system in tomatoes is used to explain concepts of gene mapping, linking and statistical analysis. The system is designed for teaching the effective use of statistics, and the power of genetic analysis from statistical analysis of phenotypic ratios. (Author/SA)

  6. APPLICATION OF STATISTICAL ENERGY ANALYSIS TO VIBRATIONS OF MULTI-PANEL STRUCTURES.

    DTIC Science & Technology

    cylindrical shell are compared with predictions obtained from statistical energy analysis . Generally good agreement is observed. The flow of mechanical...the coefficients of proportionality between power flow and average modal energy difference, which one must know in order to apply statistical energy analysis . No

  7. A Frequency Domain Approach to Pretest Analysis Model Correlation and Model Updating for the Mid-Frequency Range

    DTIC Science & Technology

    2009-02-01

    range of modal analysis and the high frequency region of statistical energy analysis , is referred to as the mid-frequency range. The corresponding...frequency range of modal analysis and the high frequency region of statistical energy analysis , is referred to as the mid-frequency range. The...predictions. The averaging process is consistent with the averaging done in statistical energy analysis for stochastic systems. The FEM will always

  8. The Shock and Vibration Bulletin. Part 2. Invited Papers, Structural Dynamics

    DTIC Science & Technology

    1974-08-01

    VIKING LANDER DYNAMICS 41 Mr. Joseph C. Pohlen, Martin Marietta Aerospace, Denver, Colorado Structural Dynamics PERFORMANCE OF STATISTICAL ENERGY ANALYSIS 47...aerospace structures. Analytical prediction of these environments is beyond the current scope of classical modal techniques. Statistical energy analysis methods...have been developed that circumvent the difficulties of high-frequency nodal analysis. These statistical energy analysis methods are evaluated

  9. A Statistical Analysis of the Output Signals of an Acousto-Optic Spectrum Analyzer for CW (Continuous-Wave) Signals

    DTIC Science & Technology

    1988-10-01

    A statistical analysis on the output signals of an acousto - optic spectrum analyzer (AOSA) is performed for the case when the input signal is a...processing, Electronic warfare, Radar countermeasures, Acousto - optic , Spectrum analyzer, Statistical analysis, Detection, Estimation, Canada, Modelling.

  10. Statistical Power in Meta-Analysis

    ERIC Educational Resources Information Center

    Liu, Jin

    2015-01-01

    Statistical power is important in a meta-analysis study, although few studies have examined the performance of simulated power in meta-analysis. The purpose of this study is to inform researchers about statistical power estimation on two sample mean difference test under different situations: (1) the discrepancy between the analytical power and…

  11. Journal of Transportation and Statistics, Vol. 3, No. 2 : special issue on the statistical analysis and modeling of automotive emissions

    DOT National Transportation Integrated Search

    2000-09-01

    This special issue of the Journal of Transportation and Statistics is devoted to the statistical analysis and modeling of automotive emissions. It contains many of the papers presented in the mini-symposium last August and also includes one additiona...

  12. A statistical package for computing time and frequency domain analysis

    NASA Technical Reports Server (NTRS)

    Brownlow, J.

    1978-01-01

    The spectrum analysis (SPA) program is a general purpose digital computer program designed to aid in data analysis. The program does time and frequency domain statistical analyses as well as some preanalysis data preparation. The capabilities of the SPA program include linear trend removal and/or digital filtering of data, plotting and/or listing of both filtered and unfiltered data, time domain statistical characterization of data, and frequency domain statistical characterization of data.

  13. The effect of different surface treatments on the shear bond strength of luting cements to titanium.

    PubMed

    Abi-Rached, Filipe de Oliveira; Fonseca, Renata Garcia; Haneda, Isabella Gagliardi; de Almeida-Júnior, Antonio Alves; Adabo, Gelson Luis

    2012-12-01

    Although titanium presents attractive physical and mechanical properties, there is a need for improving the bond at the titanium/luting cement interface for the longevity of metal ceramic restorations. The purpose of this study was to evaluate the effect of surface treatments on the shear bond strength (SBS) of resin-modified glass ionomer and resin cements to commercially pure titanium (CP Ti). Two hundred and forty CP Ti cast disks (9.0 × 3.0 mm) were divided into 8 surface treatment groups (n=30): 1) 50 µm Al(2)O(3) particles; 2) 120 µm Al(2)O(3) particles; 3) 250 µm Al(2)O(3) particles; 4) 50 µm Al(2)O(3) particles + silane (RelyX Ceramic Primer); 5) 120 µm Al(2)O(3) particles + silane; 6) 250 µm Al(2)O(3) particles + silane; 7) 30 µm silica-modified Al(2)O(3) particles (Cojet Sand) + silane; and 8) 120 µm Al(2)O(3) particles, followed by 110 µm silica-modified Al(2)O(3) particles (Rocatec). The luting cements 1) RelyX Luting 2; 2) RelyX ARC; or 3) RelyX U100 were applied to the treated CP Ti surfaces (n=10). Shear bond strength (SBS) was tested after thermal cycling (5000 cycles, 5°C to 55°C). Data were analyzed by 2-way analysis of variance (ANOVA) and the Tukey HSD post hoc test (α=.05). Failure mode was determined with a stereomicroscope (×20). The surface treatments, cements, and their interaction significantly affected the SBS (P<.001). RelyX Luting 2 and RelyX U100 exhibited similar behavior for all surface treatments. For both cements, only the group abraded with 50 μm Al(2)O(3) particles had lower SBS than the other groups (P<.05). For RelyX ARC, regardless of silane application, abrasion with 50 μm Al(2)O(3) particles resulted in significantly lower SBS than abrasion with 120 μm and 250 μm particles, which exhibited statistically similar SBS values to each other. Rocatec + silane promoted the highest SBS for RelyX ARC. RelyX U100 presented the highest SBS mean values (P<.001). All groups showed a predominance of adhesive failure mode. The adhesive capability of RelyX Luting 2 and RelyX U100 on the SBS was decisive, while for RelyX ARC, mechanical and chemical factors were more influential. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  14. Development of Composite Materials with High Passive Damping Properties

    DTIC Science & Technology

    2006-05-15

    frequency response function analysis. Sound transmission through sandwich panels was studied using the statistical energy analysis (SEA). Modal density...2.2.3 Finite element models 14 2.2.4 Statistical energy analysis method 15 CHAPTER 3 ANALYSIS OF DAMPING IN SANDWICH MATERIALS. 24 3.1 Equation of...sheets and the core. 2.2.4 Statistical energy analysis method Finite element models are generally only efficient for problems at low and middle frequencies

  15. Role of microstructure on twin nucleation and growth in HCP titanium: A statistical study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arul Kumar, M.; Wroński, M.; McCabe, Rodney James

    In this study, a detailed statistical analysis is performed using Electron Back Scatter Diffraction (EBSD) to establish the effect of microstructure on twin nucleation and growth in deformed commercial purity hexagonal close packed (HCP) titanium. Rolled titanium samples are compressed along rolling, transverse and normal directions to establish statistical correlations for {10–12}, {11–21}, and {11–22} twins. A recently developed automated EBSD-twinning analysis software is employed for the statistical analysis. Finally, the analysis provides the following key findings: (I) grain size and strain dependence is different for twin nucleation and growth; (II) twinning statistics can be generalized for the HCP metalsmore » magnesium, zirconium and titanium; and (III) complex microstructure, where grain shape and size distribution is heterogeneous, requires multi-point statistical correlations.« less

  16. Role of microstructure on twin nucleation and growth in HCP titanium: A statistical study

    DOE PAGES

    Arul Kumar, M.; Wroński, M.; McCabe, Rodney James; ...

    2018-02-01

    In this study, a detailed statistical analysis is performed using Electron Back Scatter Diffraction (EBSD) to establish the effect of microstructure on twin nucleation and growth in deformed commercial purity hexagonal close packed (HCP) titanium. Rolled titanium samples are compressed along rolling, transverse and normal directions to establish statistical correlations for {10–12}, {11–21}, and {11–22} twins. A recently developed automated EBSD-twinning analysis software is employed for the statistical analysis. Finally, the analysis provides the following key findings: (I) grain size and strain dependence is different for twin nucleation and growth; (II) twinning statistics can be generalized for the HCP metalsmore » magnesium, zirconium and titanium; and (III) complex microstructure, where grain shape and size distribution is heterogeneous, requires multi-point statistical correlations.« less

  17. Proceedings of the NASTRAN (Tradename) Users’ Colloquium (15th) Held in Kansas City, Missouri on 4-8 May 1987

    DTIC Science & Technology

    1987-08-01

    HVAC duct hanger system over an extensive frequency range. The finite element, component mode synthesis, and statistical energy analysis methods are...800-5,000 Hz) analysis was conducted with Statistical Energy Analysis (SEA) coupled with a closed-form harmonic beam analysis program. These...resonances may be obtained by using a finer frequency increment. Statistical Energy Analysis The basic assumption used in SEA analysis is that within each band

  18. [Diversity and frequency of scientific research design and statistical methods in the "Arquivos Brasileiros de Oftalmologia": a systematic review of the "Arquivos Brasileiros de Oftalmologia"--1993-2002].

    PubMed

    Crosta, Fernando; Nishiwaki-Dantas, Maria Cristina; Silvino, Wilmar; Dantas, Paulo Elias Correa

    2005-01-01

    To verify the frequency of study design, applied statistical analysis and approval by institutional review offices (Ethics Committee) of articles published in the "Arquivos Brasileiros de Oftalmologia" during a 10-year interval, with later comparative and critical analysis by some of the main international journals in the field of Ophthalmology. Systematic review without metanalysis was performed. Scientific papers published in the "Arquivos Brasileiros de Oftalmologia" between January 1993 and December 2002 were reviewed by two independent reviewers and classified according to the applied study design, statistical analysis and approval by the institutional review offices. To categorize those variables, a descriptive statistical analysis was used. After applying inclusion and exclusion criteria, 584 articles for evaluation of statistical analysis and, 725 articles for evaluation of study design were reviewed. Contingency table (23.10%) was the most frequently applied statistical method, followed by non-parametric tests (18.19%), Student's t test (12.65%), central tendency measures (10.60%) and analysis of variance (9.81%). Of 584 reviewed articles, 291 (49.82%) presented no statistical analysis. Observational case series (26.48%) was the most frequently used type of study design, followed by interventional case series (18.48%), observational case description (13.37%), non-random clinical study (8.96%) and experimental study (8.55%). We found a higher frequency of observational clinical studies, lack of statistical analysis in almost half of the published papers. Increase in studies with approval by institutional review Ethics Committee was noted since it became mandatory in 1996.

  19. Application of intracytoplasmic sperm injection (ICSI) for fertilization and development in birds.

    PubMed

    Shimada, Kiyoshi; Ono, Tamao; Mizushima, Shusei

    2014-01-15

    Intracytoplasmic sperm injection (ICSI) technology in birds has been hampered due to opacity of oocyte. We developed ICSI-assisted fertilization and gene transfer in quail. This paper reviews recent advances of our ICSI experiments. The oocyte retrieved from the oviduct and a quail sperm was injected into the oocyte under a stereomicroscope. The oocyte was cultured for 24h at 41°C under 5% CO2 in air. The fertilization and development was assessed by microscopic observation. The fertility rate ranged 12-18% and development varied from stage II to V in trials. To improve the fertility rate, phospholipase C (PLC) zeta was injected with a sperm. It was increased to 37-50%. Furthermore, injection of inositol trisphosphate increased to over 85%. Quail oocyte can be fertilized with chicken sperm and so can testicular elongated spermatid. To extend embryonic development, chicken eggshell was used as a surrogate culture at 37°C after the 24h incubation at 41°C under 5% CO2 in air. It survived up to 2days thereafter. Finally, gene transfer was attempted in quail egg. The sperm membrane was disrupted with Triton X-100 (TX-100) and was injected with PLCzeta cRNA and enhanced green fluorescent protein (EGFP) gene in oocyte. The GFP expression was evaluated at 24h incubation at 41°C under 5% CO2 in air in the embryos. While the expression was not detected in the control oocytes, the experimental treatment induced blastoderm development (44%) of the oocytes and 86% of blastoderm showed fluorescent emission. In addition, PCR analysis detected EGFP fragments in 50% of GFP-expressing blastoderm. Our ICSI method may be the first step toward the production of transgenic birds. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

    PubMed

    Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F

    2013-04-01

    This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05). Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. In vitro comparison of gutta-percha-filled area percentages in root canals instrumented and obturated with different techniques.

    PubMed

    Yilmaz, Ayca; Karagoz-Kucukay, Isil

    2017-01-01

    To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA). One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20) according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC), G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. The mean of the PGFA in Thermafil (G2), ProTaper-Obturator (G5) and HEROfill (G8) groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  2. Numerical simulating and experimental study on the woven carbon fiber-reinforced composite laminates under low-velocity impact

    NASA Astrophysics Data System (ADS)

    Liu, Hanyang; Tang, Zhanwen; Pan, Lingying; Zhao, Weidong; Sun, Baogang; Jiang, Wenge

    2016-05-01

    Impact damage has been identified as a critical form of the defects that constantly threatened the reliability of composite structures, such as those used in the aerospace structures and systems. Low energy impacts can introduce barely visible damage and cause the degradation of structural stiffness, furthermore, the flaws caused by low-velocity impact are so dangerous that they can give rise to the further extended delaminations. In order to improve the reliability and load carrying capacity of composite laminates under low-velocity impact, in this paper, the numerical simulatings and experimental studies on the woven fiber-reinforced composite laminates under low-velocity impact with impact energy 16.7J were discussed. The low velocity impact experiment was carried out through drop-weight system as the reason of inertia effect. A numerical progressive damage model was provided, in which the damages of fiber, matrix and interlamina were considered by VUMT subroutine in ABAQUS, to determine the damage modes. The Hashin failure criteria were improved to cover the failure modes of fiber failure in the directions of warp/weft and delaminations. The results of Finite Element Analysis (FEA) were compared with the experimental results of nondestructive examination including the results of ultrasonic C-scan, cross-section stereomicroscope and contact force - time history curves. It is found that the response of laminates under low-velocity impact could be divided into stages with different damage. Before the max-deformation of the laminates occurring, the matrix cracking, fiber breakage and delaminations were simulated during the impactor dropping. During the releasing and rebounding period, matrix cracking and delaminations areas kept increasing in the laminates because of the stress releasing of laminates. Finally, the simulating results showed the good agreements with the results of experiment.

  3. Evaluation of enamel damages following orthodontic bracket debonding in fluorosed teeth bonded with adhesion promoter.

    PubMed

    Baherimoghadam, Tahreh; Akbarian, Sahar; Rasouli, Reza; Naseri, Navid

    2016-01-01

    To evaluate shear bond strength (SBS) of the orthodontic brackets bonded to fluorosed and nonfluorosed teeth using Light Bond with and without adhesion promoters and compare their enamel damages following debonding. In this study, 30 fluorosed (Thylstrup and Fejerskov Index = 4-5) and 30 nonfluorosed teeth were randomly distributed between two subgroups according to the bonding materials: Group 1, fluorosed teeth bonded with Light Bond; Group 2, fluorosed teeth bonded with adhesion promoters and Light Bond; Group 3, nonfluorosed teeth bonded with Light Bond; Group 4, nonfluorosed bonded with adhesion promoters and Light Bond. After bonding, the SBS of the brackets was tested with a universal testing machine. Stereomicroscopic evaluation was performed by unbiased stereology in all teeth to determine the amount of adhesive remnants and the number and length of enamel cracks before bonding and after debonding. The data were analyzed using two-way analysis of variance, Kruskal-Wallis, Wilcoxon Signed Rank, and Mann-Whitney test. While fluorosis reduced the SBS of orthodontic bracket (P = 0.017), Enhance Locus Ceruleus LC significantly increased the SBS of the orthodontic bracket in fluorosed and nonfluorosed teeth (P = 0.039). Significant increasing in the number and length of enamel crack after debonding was found in all four groups. There were no significant differences in the length of enamel crack increased after debonding among four groups (P = 0.768) while increasing in the number of enamel cracks after debonding was significantly different among the four groups (P = 0.023). Teeth in Group 2 showed the highest enamel damages among four groups following debonding. Adhesion promoters could improve the bond strength of orthodontic brackets, but conservative debonding methods for decreasing enamel damages would be necessary.

  4. Changes in inflorescence protein during advanced stages of floret development in Buchloe dactyloides (Poaceae).

    PubMed

    Zhou, Y-J; Xue, J-G; Wang, X-G; Zhang, X-Q

    2012-11-12

    Buffalograss, Buchloe dactyloides, is a dioecious species native to the Great Plains of North America. The florets at the early stages of development possess both gynoecium and androecium organ primordia but later become unisexual. Very little is known about the proteomic changes that occur when the florets change from hermaphroditism to unisexuality. We compared the protein composition of florets at the hermaphroditic stage with that at the unisexual stage. The development stage of the floret was determined by stereomicroscopic observation. Two-dimensional gel electrophoresis was used to separate the proteins extracted from female and male inflorescences. Stage- specific protein maps, with an average of about 400 spots per map, were analyzed with the protein analysis software. Eighteen spots were found to be differentially expressed between the hermaphrodite and unisexual stages. Of these, 12 were present at both stages but with a different expression value. Four specific spots appeared at the hermaphrodite stage and disappeared at the unisexual stage. Two specific protein spots were associated with female and male floret differentiation. One appears to be associated with contabescence in the female floret and the final protein appears to lead to the abortion of gynoecium in the male floret. The MALDI TOF/TOF technique was used for peptide mass fingerprinting of the differentially expressed proteins and the MASCOT software was used to search the protein database. However, only two protein spots were identified from the database. These were aldolase1 and Os05g0574400 (similar to malate dehydrogenase). This type of proteomic study can help to identify novel protein products and determine the mechanisms involved in the floral sex differentiation process in buffalo grass.

  5. Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination.

    PubMed

    Khanehmasjedi, Mashallah; Naseri, Mohammad Ali; Khanehmasjedi, Samaneh; Basir, Leila

    2017-02-01

    This study compared the shear bond strength of metallic brackets bonded with Single Bond and Assure bonding agents under dry and saliva-contamination conditions. Sixty sound premolar teeth were selected, and stainless-steel brackets were bonded on enamel surfaces with Single Bond and Assure bonding agents under dry condition or with saliva contamination. Shear bond strength values of brackets were measured in a universal testing machine. The adhesive remnant index scores were determined after debonding of the brackets under a stereomicroscope. One-way analysis of variance (ANOVA) was used to analyze bond strength. Two-by-two comparisons were made with post hoc Tukey tests (p<0.001). Frequencies of adhesive remnant index scores were analyzed by Kruskal-Wallis test. Bond strength values of brackets to tooth structure were 9.29±8.56 MPa and 21.25±8.93 MPa with the use of Assure resin bonding agent under saliva-contamination and dry conditions, respectively. These values were 10.13±6.69 MPa and 14.09±6.6 MPa, respectively, under the same conditions with the use of Single Bond adhesive. Contamination with saliva resulted in a significant decrease in the bond strength of brackets to tooth structure with the application of Assure adhesive resin (p<0.001). There were no significant differences in the adhesive remnant index scores between the study groups. Application of Single Bond and Assure bonding agents resulted in adequate bond strength of brackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared with dry conditions. Copyright © 2016. Published by Elsevier Taiwan LLC.

  6. Effect of acid and laser etching on shear bond strength of conventional and resin-modified glass-ionomer cements to composite resin.

    PubMed

    Navimipour, Elmira Jafari; Oskoee, Siavash Savadi; Oskoee, Parnian Alizadeh; Bahari, Mahmoud; Rikhtegaran, Sahand; Ghojazadeh, Morteza

    2012-03-01

    Success in sandwich technique procedures can be achieved through an acceptable bond between the materials. The aim of this study was to compare the effect of 35% phosphoric acid and Er,Cr:YSGG laser on shear bond strength of conventional glass-ionomer cement (GIC) and resin-modified glass-ionomer cement (RMGIC) to composite resin in sandwich technique. Sixty-six specimens were prepared from each type of glass-ionomer cements and divided into three treatment groups as follows: without pretreatment, acid etching by 35% phosphoric acid for 15 s, and 1-W Er,Cr:YSGG laser treatment for 15 s with a 600-μm-diameter tip aligned perpendicular to the target area at a distance of 1 mm from the surface. Energy density of laser irradiation was 17.7 J/cm(2). Two specimens in each group were prepared for evaluation under a scanning electron microscope (SEM) after surface treatment and the remainder underwent bonding procedure with a bonding agent and composite resin. Then the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Two-factor analysis of variance and post-hoc Tukey test showed that the cement type, surface treatment method, and the interaction of these two factors significantly affect the shear bond strength between glass-ionomer cements and composite resin (p < 0.05). Surface treatment with phosphoric acid or Er,Cr:YSGG laser increased the shear bond strength of GIC to composite resin; however, in RMGIC only laser etching resulted in significantly higher bond strength. These findings were supported by SEM results. The fracture mode was evaluated under a stereomicroscope at ×20.

  7. Pollinarium morphology and floral rewards in Brazilian Maxillariinae (Orchidaceae).

    PubMed

    Singer, Rodrigo B; Koehler, Samantha

    2004-01-01

    There is strong support for the monophyly of the orchid subtribe Maxillariinae s.l., yet generic boundaries within it are unsatisfactory and need re-evaluation. In an effort to assemble sets of morphological characters to distinguish major clades within this subtribe, the pollinarium morphology and floral rewards of representative Brazilian species of this subtribe were studied. The study was based on fresh material from 60 species and seven genera obtained from cultivated specimens. Variation of pollinarium structure and floral rewards was assessed using a stereomicroscope and by SEM analysis. Four morphological types of pollinaria are described. Type 1 appears to be the most widespread and is characterized by a well-developed tegula. Type 2 lacks a stipe and the pollinia are attached directly to the viscidium. Type 3 also lacks a stipe, and the viscidium is rigid and dark. In Type 4, the stipe consists of the whole median rostelar portion and, so far, is known only from Maxillaria uncata. Nectar, trichomes, wax-like and resin-like secretions are described as flower rewards for different groups of species within the genus Maxillaria. Data on the biomechanics and pollination biology are also discussed and illustrated. In Maxillariinae flowers with arcuate viscidia, the pollinaria are deposited on the scuttellum of their Hymenopteran pollinators. In contrast, some flowers with rounded to rectangular, pad-like viscidia fix their pollinaria on the face of their pollinators. Pollinarium morphology and floral features related to pollination in Brazilian Maxillariinae are more diverse than previously suggested. It is hoped that the data presented herein, together with other data sources such as vegetative traits and molecular tools, will be helpful in redefining and diagnosing clades within the subtribe Maxillariinae.

  8. Pollinarium Morphology and Floral Rewards inBrazilian Maxillariinae (Orchidaceae)

    PubMed Central

    SINGER, RODRIGO B.; KOEHLER, SAMANTHA

    2004-01-01

    • Background and Aims There is strong support for the monophyly of the orchid subtribe Maxillariinae s.l., yet generic boundaries within it are unsatisfactory and need re‐evaluation. In an effort to assemble sets of morphological characters to distinguish major clades within this subtribe, the pollinarium morphology and floral rewards of representative Brazilian species of this subtribe were studied. • Methods The study was based on fresh material from 60 species and seven genera obtained from cultivated specimens. Variation of pollinarium structure and floral rewards was assessed using a stereomicroscope and by SEM analysis. • Key Results Four morphological types of pollinaria are described. Type 1 appears to be the most widespread and is characterized by a well‐developed tegula. Type 2 lacks a stipe and the pollinia are attached directly to the viscidium. Type 3 also lacks a stipe, and the viscidium is rigid and dark. In Type 4, the stipe consists of the whole median rostelar portion and, so far, is known only from Maxillaria uncata. Nectar, trichomes, wax‐like and resin‐like secretions are described as flower rewards for different groups of species within the genus Maxillaria. Data on the biomechanics and pollination biology are also discussed and illustrated. In Maxillariinae flowers with arcuate viscidia, the pollinaria are deposited on the scuttellum of their Hymenopteran pollinators. In contrast, some flowers with rounded to rectangular, pad‐like viscidia fix their pollinaria on the face of their pollinators. • Conclusions Pollinarium morphology and floral features related to pollination in Brazilian Maxillariinae are more diverse than previously suggested. It is hoped that the data presented herein, together with other data sources such as vegetative traits and molecular tools, will be helpful in redefining and diagnosing clades within the subtribe Maxillariinae. PMID:14644913

  9. Stereomicroscopic study on unsectioned extracted teeth

    PubMed Central

    Narayan, V. Keerthi; Varsha, V. K.; Girish, H. C.; Murgod, Sanjay

    2017-01-01

    Introduction: Age has been considered as a reliable marker for establishing the identity of a person in the field of forensic medicine. Teeth are useful skeletal indicators of age at death since it can survive for decades. Nondestructive methods ensure the evident preservation of dental hard tissues that reflect age changes from the cradle to the grave. Therefore, an attempt was made for estimating the age using the nondestructive method. Aims and Objectives: The aim of this study to assess whether physiological changes of the teeth allow possible correlation for accurate age estimation and to establish a graduation standard by microscopic observation for a better age correlation. Materials and Methods: The study was carried on 209 teeth samples extracted for orthodontic treatment or periodontal diseases comprised both maxillary and mandibular teeth across different age groups. The assessment of these changes was carried out by well-established standard methods with some proposed modifications. Results: Pearson correlation analyses revealed root dentin translucency with the highest correlation (r = 0.97) followed by periodontal ligament attachment (r = 0.95), root dentin color (r = 0.95), and attrition being the least correlated (r = 0.90). All the parameters taken for the study contributed to stepwise linear regression analysis (R = 0.98; P < 0.01) indicating a strongly positive relationship between age and the changes observed. A regression formula was obtained with mean error age difference ±1.0 years. Conclusion: The present study showed that extracted tooth is highly significant in identifying the age without being sectioned or further processed and also signifies the use of microscope for observation of these changes, thus reducing the errors of calibrating the age. PMID:29657494

  10. Timing considerations on the shear bond strength of orthodontic brackets after topical fluoride varnish applications

    PubMed Central

    Cossellu, Gianguido; Lanteri, Valentina; Butera, Andrea; Laffi, Nicola; Merlini, Alberto; Farronato, Giampietro

    2017-01-01

    Objectives: To assess the best temporal association between the application of a fluoride varnish on enamel and bonding procedures. Materials and Methods: Eighty mandibular bovine incisors were used. Teeth were divided into 4 groups (20 per group); Groups 1–3 were treated with fluoride varnish (Fluor Protector, Ivoclar Vivadent, Schaan, Liechtenstein), and Group 4 served as control with no pretreatment. Tooth were stored in deionized water (37°C) and subjected to thermal cycling for 400 (Group 1), 800 (Group 2), and 2500 (Group 3) cycles corresponding, respectively, to 15, 30, and 90 days in order to simulate the three different timing of bracket bonding. Shear bond strength (SBS) was measured using an Instron Universal Testing machine. Tooth surfaces were examined under a stereomicroscope at 10× magnification to assess the amount of adhesive remnant index (ARI). One-way analysis of variance (ANOVA) and Tukey's honestly significant difference post-hoc test were used for the comparison of SBS values between groups (P < 0.05). The Chi-square test was used to examine differences among ARI scores. (P < 0.05). Results: One-way ANOVA and Tukey post-hoc test showed that the SBS of different groups were significantly different and was impacted by different timing of bonding (P < 0.05). The main differences were between the control group (17.02 ± 6.38 MPa) and Group 1 (6.93 ± 4.3 MPa). The ARI scores showed that there were no significant differences between the four tested groups. Conclusions: The SBS of the brackets bonded 15 days after the application of the fluoride was set back to an optimal value. PMID:28197397

  11. Sexual mimicry in Mormolyca ringens (Lindl.) Schltr. (Orchidaceae: Maxillariinae).

    PubMed

    Singer, Rodrigo B; Flach, Adriana; Koehler, Samantha; Marsaioli, Anita J; Amaral, Maria do Carmo E

    2004-06-01

    Pollination through sexual mimicry, also known as pseudocopulation, has been suggested to occur in some genera of the Neotropical orchid subtribe Maxillariinae. However, it has been demonstrated so far only for Trigonidium obtusum. This study reports and illustrates pollination through sexual mimicry in Mormolyca ringens. A total of 70 h were dedicated to the observation of flowers and pollinator behaviour, which was photographically recorded. Flower features involved in pollinator attraction were studied using a stereomicroscope and by SEM analyses. Preliminary observations on the plant breeding system were made by manually self-pollinating flowers. The chemical composition of the fragrance volatiles was determined by GC/MS analysis. The flower features of M. ringens parallel those of other pseudocopulatory flowers. The labellum shape and indument are reminiscent of an insect. Sexually excited drones of Nannotrigona testaceicornis and Scaptotrigona sp. (both in the Apidae: Meliponini) attempt copulation with the labellum and pollinate the flower in the process. In both bee species, the pollinarium is attached to the scutellum. Pollinator behaviour may promote some degree of self-pollination, but preliminary observations indicate that M. ringens flowers are self-incompatible. Flowers are produced all the year round, which ties in with the production of bee males several times a year. The phylogenetic relationships of M. ringens are discussed and a number of morphological and phenological features supporting them are reported. It is expected that further research could bring to light whether other Maxillariinae species are also pollinated through sexual mimicry. When a definitive and robust phylogeny of this subtribe is available, it should be possible to determine how many times pseudocopulation evolved and its possible evolutionary history.

  12. Experimental Quiet Sprocket Design and Noise Reduction in Tracked Vehicles

    DTIC Science & Technology

    1981-04-01

    Track and Suspension Noise Reduction Statistical Energy Analysis Mechanical Impedance Measurement Finite Element Modal Analysis\\Noise Sources 2...shape and idler attachment are different. These differen- ces were investigated using the concepts of statistical energy analysis for hull generated noise...element r,’calculated from Statistical Energy Analysis . Such an approach will be valid within reasonable limits for frequencies of about 200 Hz and

  13. Compendium of Methods for Applying Measured Data to Vibration and Acoustic Problems

    DTIC Science & Technology

    1985-10-01

    statistical energy analysis , finite element models, transfer function...Procedures for the Modal Analysis Method .............................................. 8-22 8.4 Summary of the Procedures for the Statistical Energy Analysis Method... statistical energy analysis . 8-1 • o + . . i... "_+,A" L + "+..• •+A ’! i, + +.+ +• o.+ -ore -+. • -..- , .%..% ". • 2 -".-2- ;.-.’, . o . It is helpful

  14. [Statistical analysis of German radiologic periodicals: developmental trends in the last 10 years].

    PubMed

    Golder, W

    1999-09-01

    To identify which statistical tests are applied in German radiological publications, to what extent their use has changed during the last decade, and which factors might be responsible for this development. The major articles published in "ROFO" and "DER RADIOLOGE" during 1988, 1993 and 1998 were reviewed for statistical content. The contributions were classified by principal focus and radiological subspecialty. The methods used were assigned to descriptive, basal and advanced statistics. Sample size, significance level and power were established. The use of experts' assistance was monitored. Finally, we calculated the so-called cumulative accessibility of the publications. 525 contributions were found to be eligible. In 1988, 87% used descriptive statistics only, 12.5% basal, and 0.5% advanced statistics. The corresponding figures in 1993 and 1998 are 62 and 49%, 32 and 41%, and 6 and 10%, respectively. Statistical techniques were most likely to be used in research on musculoskeletal imaging and articles dedicated to MRI. Six basic categories of statistical methods account for the complete statistical analysis appearing in 90% of the articles. ROC analysis is the single most common advanced technique. Authors make increasingly use of statistical experts' opinion and programs. During the last decade, the use of statistical methods in German radiological journals has fundamentally improved, both quantitatively and qualitatively. Presently, advanced techniques account for 20% of the pertinent statistical tests. This development seems to be promoted by the increasing availability of statistical analysis software.

  15. Teaching Statistics in Biology: Using Inquiry-based Learning to Strengthen Understanding of Statistical Analysis in Biology Laboratory Courses

    PubMed Central

    2008-01-01

    There is an increasing need for students in the biological sciences to build a strong foundation in quantitative approaches to data analyses. Although most science, engineering, and math field majors are required to take at least one statistics course, statistical analysis is poorly integrated into undergraduate biology course work, particularly at the lower-division level. Elements of statistics were incorporated into an introductory biology course, including a review of statistics concepts and opportunity for students to perform statistical analysis in a biological context. Learning gains were measured with an 11-item statistics learning survey instrument developed for the course. Students showed a statistically significant 25% (p < 0.005) increase in statistics knowledge after completing introductory biology. Students improved their scores on the survey after completing introductory biology, even if they had previously completed an introductory statistics course (9%, improvement p < 0.005). Students retested 1 yr after completing introductory biology showed no loss of their statistics knowledge as measured by this instrument, suggesting that the use of statistics in biology course work may aid long-term retention of statistics knowledge. No statistically significant differences in learning were detected between male and female students in the study. PMID:18765754

  16. Communications Link Characterization Experiment (CLCE) technical data report, volume 2

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The results are presented of the long term rain rate statistical analysis and the investigation of determining the worst month statistical from the measured attenuation data caused by precipitation. The rain rate statistics cover a period of 11 months from July of 1974 to May of 1975 for measurements taken at the NASA, Rosman station. The rain rate statistical analysis is a continuation of the analysis of the rain rate data accumulated for the ATS-6 Millimeter Wave Progation Experiment. The statistical characteristics of the rain rate data through December of 1974 is also presented for the above experiment.

  17. Deconstructing Statistical Analysis

    ERIC Educational Resources Information Center

    Snell, Joel

    2014-01-01

    Using a very complex statistical analysis and research method for the sake of enhancing the prestige of an article or making a new product or service legitimate needs to be monitored and questioned for accuracy. 1) The more complicated the statistical analysis, and research the fewer the number of learned readers can understand it. This adds a…

  18. An evaluation of the quality of statistical design and analysis of published medical research: results from a systematic survey of general orthopaedic journals.

    PubMed

    Parsons, Nick R; Price, Charlotte L; Hiskens, Richard; Achten, Juul; Costa, Matthew L

    2012-04-25

    The application of statistics in reported research in trauma and orthopaedic surgery has become ever more important and complex. Despite the extensive use of statistical analysis, it is still a subject which is often not conceptually well understood, resulting in clear methodological flaws and inadequate reporting in many papers. A detailed statistical survey sampled 100 representative orthopaedic papers using a validated questionnaire that assessed the quality of the trial design and statistical analysis methods. The survey found evidence of failings in study design, statistical methodology and presentation of the results. Overall, in 17% (95% confidence interval; 10-26%) of the studies investigated the conclusions were not clearly justified by the results, in 39% (30-49%) of studies a different analysis should have been undertaken and in 17% (10-26%) a different analysis could have made a difference to the overall conclusions. It is only by an improved dialogue between statistician, clinician, reviewer and journal editor that the failings in design methodology and analysis highlighted by this survey can be addressed.

  19. Application of Ontology Technology in Health Statistic Data Analysis.

    PubMed

    Guo, Minjiang; Hu, Hongpu; Lei, Xingyun

    2017-01-01

    Research Purpose: establish health management ontology for analysis of health statistic data. Proposed Methods: this paper established health management ontology based on the analysis of the concepts in China Health Statistics Yearbook, and used protégé to define the syntactic and semantic structure of health statistical data. six classes of top-level ontology concepts and their subclasses had been extracted and the object properties and data properties were defined to establish the construction of these classes. By ontology instantiation, we can integrate multi-source heterogeneous data and enable administrators to have an overall understanding and analysis of the health statistic data. ontology technology provides a comprehensive and unified information integration structure of the health management domain and lays a foundation for the efficient analysis of multi-source and heterogeneous health system management data and enhancement of the management efficiency.

  20. [The research protocol VI: How to choose the appropriate statistical test. Inferential statistics].

    PubMed

    Flores-Ruiz, Eric; Miranda-Novales, María Guadalupe; Villasís-Keever, Miguel Ángel

    2017-01-01

    The statistical analysis can be divided in two main components: descriptive analysis and inferential analysis. An inference is to elaborate conclusions from the tests performed with the data obtained from a sample of a population. Statistical tests are used in order to establish the probability that a conclusion obtained from a sample is applicable to the population from which it was obtained. However, choosing the appropriate statistical test in general poses a challenge for novice researchers. To choose the statistical test it is necessary to take into account three aspects: the research design, the number of measurements and the scale of measurement of the variables. Statistical tests are divided into two sets, parametric and nonparametric. Parametric tests can only be used if the data show a normal distribution. Choosing the right statistical test will make it easier for readers to understand and apply the results.

  1. Modified Distribution-Free Goodness-of-Fit Test Statistic.

    PubMed

    Chun, So Yeon; Browne, Michael W; Shapiro, Alexander

    2018-03-01

    Covariance structure analysis and its structural equation modeling extensions have become one of the most widely used methodologies in social sciences such as psychology, education, and economics. An important issue in such analysis is to assess the goodness of fit of a model under analysis. One of the most popular test statistics used in covariance structure analysis is the asymptotically distribution-free (ADF) test statistic introduced by Browne (Br J Math Stat Psychol 37:62-83, 1984). The ADF statistic can be used to test models without any specific distribution assumption (e.g., multivariate normal distribution) of the observed data. Despite its advantage, it has been shown in various empirical studies that unless sample sizes are extremely large, this ADF statistic could perform very poorly in practice. In this paper, we provide a theoretical explanation for this phenomenon and further propose a modified test statistic that improves the performance in samples of realistic size. The proposed statistic deals with the possible ill-conditioning of the involved large-scale covariance matrices.

  2. Statistical power in parallel group point exposure studies with time-to-event outcomes: an empirical comparison of the performance of randomized controlled trials and the inverse probability of treatment weighting (IPTW) approach.

    PubMed

    Austin, Peter C; Schuster, Tibor; Platt, Robert W

    2015-10-15

    Estimating statistical power is an important component of the design of both randomized controlled trials (RCTs) and observational studies. Methods for estimating statistical power in RCTs have been well described and can be implemented simply. In observational studies, statistical methods must be used to remove the effects of confounding that can occur due to non-random treatment assignment. Inverse probability of treatment weighting (IPTW) using the propensity score is an attractive method for estimating the effects of treatment using observational data. However, sample size and power calculations have not been adequately described for these methods. We used an extensive series of Monte Carlo simulations to compare the statistical power of an IPTW analysis of an observational study with time-to-event outcomes with that of an analysis of a similarly-structured RCT. We examined the impact of four factors on the statistical power function: number of observed events, prevalence of treatment, the marginal hazard ratio, and the strength of the treatment-selection process. We found that, on average, an IPTW analysis had lower statistical power compared to an analysis of a similarly-structured RCT. The difference in statistical power increased as the magnitude of the treatment-selection model increased. The statistical power of an IPTW analysis tended to be lower than the statistical power of a similarly-structured RCT.

  3. Network Data: Statistical Theory and New Models

    DTIC Science & Technology

    2016-02-17

    SECURITY CLASSIFICATION OF: During this period of review, Bin Yu worked on many thrusts of high-dimensional statistical theory and methodologies. Her...research covered a wide range of topics in statistics including analysis and methods for spectral clustering for sparse and structured networks...2,7,8,21], sparse modeling (e.g. Lasso) [4,10,11,17,18,19], statistical guarantees for the EM algorithm [3], statistical analysis of algorithm leveraging

  4. Quantifying the impact of between-study heterogeneity in multivariate meta-analyses

    PubMed Central

    Jackson, Dan; White, Ian R; Riley, Richard D

    2012-01-01

    Measures that quantify the impact of heterogeneity in univariate meta-analysis, including the very popular I2 statistic, are now well established. Multivariate meta-analysis, where studies provide multiple outcomes that are pooled in a single analysis, is also becoming more commonly used. The question of how to quantify heterogeneity in the multivariate setting is therefore raised. It is the univariate R2 statistic, the ratio of the variance of the estimated treatment effect under the random and fixed effects models, that generalises most naturally, so this statistic provides our basis. This statistic is then used to derive a multivariate analogue of I2, which we call . We also provide a multivariate H2 statistic, the ratio of a generalisation of Cochran's heterogeneity statistic and its associated degrees of freedom, with an accompanying generalisation of the usual I2 statistic, . Our proposed heterogeneity statistics can be used alongside all the usual estimates and inferential procedures used in multivariate meta-analysis. We apply our methods to some real datasets and show how our statistics are equally appropriate in the context of multivariate meta-regression, where study level covariate effects are included in the model. Our heterogeneity statistics may be used when applying any procedure for fitting the multivariate random effects model. Copyright © 2012 John Wiley & Sons, Ltd. PMID:22763950

  5. Shock and Vibration Symposium (59th) Held in Albuquerque, New Mexico on 18-20 October 1988. Volume 3

    DTIC Science & Technology

    1988-10-01

    N. F. Rieger Statistical Energy Analysis : An Overview of Its Development and Engineering Applications J. E. Manning DATA BASES DOE/DOD Environmental...Vibroacoustic Response Using the Finite Element Method and Statistical Energy Analysis F. L. Gloyna Study of Helium Effect on Spacecraft Random Vibration...Analysis S. A. Wilkerson vi DYNAMIC ANALYSIS Modeling of Vibration Transmission in a Damped Beam Structure Using Statistical Energy Analysis S. S

  6. Analysis and Report on SD2000: A Workshop to Determine Structural Dynamics Research for the Millenium

    DTIC Science & Technology

    2000-04-10

    interest. These include Statistical Energy Analysis (SEA), fuzzy structure theory, and approaches combining modal analysis and SEA. Non-determinism...34 arising with increasing frequency. This has led to Statistical Energy Analysis , in which a system is modelled as a collection of coupled subsystems...22. IUTAM Symposium on Statistical Energy Analysis . 1999 Ed. F.J. Fahy and W.G. Price. Kluwer Academic Publishing. • 23. R.S. Langley and P

  7. An overview of the mathematical and statistical analysis component of RICIS

    NASA Technical Reports Server (NTRS)

    Hallum, Cecil R.

    1987-01-01

    Mathematical and statistical analysis components of RICIS (Research Institute for Computing and Information Systems) can be used in the following problem areas: (1) quantification and measurement of software reliability; (2) assessment of changes in software reliability over time (reliability growth); (3) analysis of software-failure data; and (4) decision logic for whether to continue or stop testing software. Other areas of interest to NASA/JSC where mathematical and statistical analysis can be successfully employed include: math modeling of physical systems, simulation, statistical data reduction, evaluation methods, optimization, algorithm development, and mathematical methods in signal processing.

  8. Statistical Energy Analysis (SEA) and Energy Finite Element Analysis (EFEA) Predictions for a Floor-Equipped Composite Cylinder

    NASA Technical Reports Server (NTRS)

    Grosveld, Ferdinand W.; Schiller, Noah H.; Cabell, Randolph H.

    2011-01-01

    Comet Enflow is a commercially available, high frequency vibroacoustic analysis software founded on Energy Finite Element Analysis (EFEA) and Energy Boundary Element Analysis (EBEA). Energy Finite Element Analysis (EFEA) was validated on a floor-equipped composite cylinder by comparing EFEA vibroacoustic response predictions with Statistical Energy Analysis (SEA) and experimental results. Statistical Energy Analysis (SEA) predictions were made using the commercial software program VA One 2009 from ESI Group. The frequency region of interest for this study covers the one-third octave bands with center frequencies from 100 Hz to 4000 Hz.

  9. An Analysis of the Navy’s Voluntary Education Program

    DTIC Science & Technology

    2007-03-01

    NAVAL ANALYSIS VOLED STUDY .........11 1. Data .........................................11 2. Statistical Models ...........................12 3...B. EMPLOYER FINANCED GENERAL TRAINING ................31 1. Data .........................................32 2. Statistical Model...37 1. Data .........................................38 2. Statistical Model ............................38 3. Findings

  10. The Shock and Vibration Digest. Volume 14, Number 12

    DTIC Science & Technology

    1982-12-01

    to evaluate the uses of statistical energy analysis for determining sound transmission performance. Coupling loss factors were mea- sured and compared...measurements for the artificial (Also see No. 2623) cracks in mild-steel test pieces. 82-2676 Ihprovement of the Method of Statistical Energy Analysis for...eters, using a large number of free-response time histories In the application of the statistical energy analysis theory simultaneously in one analysis

  11. Statistical Symbolic Execution with Informed Sampling

    NASA Technical Reports Server (NTRS)

    Filieri, Antonio; Pasareanu, Corina S.; Visser, Willem; Geldenhuys, Jaco

    2014-01-01

    Symbolic execution techniques have been proposed recently for the probabilistic analysis of programs. These techniques seek to quantify the likelihood of reaching program events of interest, e.g., assert violations. They have many promising applications but have scalability issues due to high computational demand. To address this challenge, we propose a statistical symbolic execution technique that performs Monte Carlo sampling of the symbolic program paths and uses the obtained information for Bayesian estimation and hypothesis testing with respect to the probability of reaching the target events. To speed up the convergence of the statistical analysis, we propose Informed Sampling, an iterative symbolic execution that first explores the paths that have high statistical significance, prunes them from the state space and guides the execution towards less likely paths. The technique combines Bayesian estimation with a partial exact analysis for the pruned paths leading to provably improved convergence of the statistical analysis. We have implemented statistical symbolic execution with in- formed sampling in the Symbolic PathFinder tool. We show experimentally that the informed sampling obtains more precise results and converges faster than a purely statistical analysis and may also be more efficient than an exact symbolic analysis. When the latter does not terminate symbolic execution with informed sampling can give meaningful results under the same time and memory limits.

  12. The estimation of the measurement results with using statistical methods

    NASA Astrophysics Data System (ADS)

    Velychko, O.; Gordiyenko, T.

    2015-02-01

    The row of international standards and guides describe various statistical methods that apply for a management, control and improvement of processes with the purpose of realization of analysis of the technical measurement results. The analysis of international standards and guides on statistical methods estimation of the measurement results recommendations for those applications in laboratories is described. For realization of analysis of standards and guides the cause-and-effect Ishikawa diagrams concerting to application of statistical methods for estimation of the measurement results are constructed.

  13. Limitations of Using Microsoft Excel Version 2016 (MS Excel 2016) for Statistical Analysis for Medical Research.

    PubMed

    Tanavalee, Chotetawan; Luksanapruksa, Panya; Singhatanadgige, Weerasak

    2016-06-01

    Microsoft Excel (MS Excel) is a commonly used program for data collection and statistical analysis in biomedical research. However, this program has many limitations, including fewer functions that can be used for analysis and a limited number of total cells compared with dedicated statistical programs. MS Excel cannot complete analyses with blank cells, and cells must be selected manually for analysis. In addition, it requires multiple steps of data transformation and formulas to plot survival analysis graphs, among others. The Megastat add-on program, which will be supported by MS Excel 2016 soon, would eliminate some limitations of using statistic formulas within MS Excel.

  14. Database Creation and Statistical Analysis: Finding Connections Between Two or More Secondary Storage Device

    DTIC Science & Technology

    2017-09-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS DATABASE CREATION AND STATISTICAL ANALYSIS: FINDING CONNECTIONS BETWEEN TWO OR MORE SECONDARY...BLANK ii Approved for public release. Distribution is unlimited. DATABASE CREATION AND STATISTICAL ANALYSIS: FINDING CONNECTIONS BETWEEN TWO OR MORE...Problem and Motivation . . . . . . . . . . . . . . . . . . . 1 1.2 DOD Applicability . . . . . . . . . . . . . . . . .. . . . . . . 2 1.3 Research

  15. Vibration Transmission through Rolling Element Bearings in Geared Rotor Systems

    DTIC Science & Technology

    1990-11-01

    147 4.8 Concluding Remarks ........................................................... 153 V STATISTICAL ENERGY ANALYSIS ............................................ 155...and dynamic finite element techniques are used to develop the discrete vibration models while statistical energy analysis method is used for the broad...bearing system studies, geared rotor system studies, and statistical energy analysis . Each chapter is self sufficient since it is written in a

  16. Statistics Education Research in Malaysia and the Philippines: A Comparative Analysis

    ERIC Educational Resources Information Center

    Reston, Enriqueta; Krishnan, Saras; Idris, Noraini

    2014-01-01

    This paper presents a comparative analysis of statistics education research in Malaysia and the Philippines by modes of dissemination, research areas, and trends. An electronic search for published research papers in the area of statistics education from 2000-2012 yielded 20 for Malaysia and 19 for the Philippines. Analysis of these papers showed…

  17. Statistical analysis and interpretation of prenatal diagnostic imaging studies, Part 2: descriptive and inferential statistical methods.

    PubMed

    Tuuli, Methodius G; Odibo, Anthony O

    2011-08-01

    The objective of this article is to discuss the rationale for common statistical tests used for the analysis and interpretation of prenatal diagnostic imaging studies. Examples from the literature are used to illustrate descriptive and inferential statistics. The uses and limitations of linear and logistic regression analyses are discussed in detail.

  18. Interrupted Time Series Versus Statistical Process Control in Quality Improvement Projects.

    PubMed

    Andersson Hagiwara, Magnus; Andersson Gäre, Boel; Elg, Mattias

    2016-01-01

    To measure the effect of quality improvement interventions, it is appropriate to use analysis methods that measure data over time. Examples of such methods include statistical process control analysis and interrupted time series with segmented regression analysis. This article compares the use of statistical process control analysis and interrupted time series with segmented regression analysis for evaluating the longitudinal effects of quality improvement interventions, using an example study on an evaluation of a computerized decision support system.

  19. General Framework for Meta-analysis of Rare Variants in Sequencing Association Studies

    PubMed Central

    Lee, Seunggeun; Teslovich, Tanya M.; Boehnke, Michael; Lin, Xihong

    2013-01-01

    We propose a general statistical framework for meta-analysis of gene- or region-based multimarker rare variant association tests in sequencing association studies. In genome-wide association studies, single-marker meta-analysis has been widely used to increase statistical power by combining results via regression coefficients and standard errors from different studies. In analysis of rare variants in sequencing studies, region-based multimarker tests are often used to increase power. We propose meta-analysis methods for commonly used gene- or region-based rare variants tests, such as burden tests and variance component tests. Because estimation of regression coefficients of individual rare variants is often unstable or not feasible, the proposed method avoids this difficulty by calculating score statistics instead that only require fitting the null model for each study and then aggregating these score statistics across studies. Our proposed meta-analysis rare variant association tests are conducted based on study-specific summary statistics, specifically score statistics for each variant and between-variant covariance-type (linkage disequilibrium) relationship statistics for each gene or region. The proposed methods are able to incorporate different levels of heterogeneity of genetic effects across studies and are applicable to meta-analysis of multiple ancestry groups. We show that the proposed methods are essentially as powerful as joint analysis by directly pooling individual level genotype data. We conduct extensive simulations to evaluate the performance of our methods by varying levels of heterogeneity across studies, and we apply the proposed methods to meta-analysis of rare variant effects in a multicohort study of the genetics of blood lipid levels. PMID:23768515

  20. Primary, Secondary, and Meta-Analysis of Research

    ERIC Educational Resources Information Center

    Glass, Gene V.

    1976-01-01

    Examines data analysis at three levels: analysis of data; secondary analysis is the re-analysis of data for the purpose of answering the original research question with better statistical techniques, or answering new questions with old data; and, meta-analysis refers to the statistical analysis of many analysis results from individual studies for…

  1. [Statistical analysis using freely-available "EZR (Easy R)" software].

    PubMed

    Kanda, Yoshinobu

    2015-10-01

    Clinicians must often perform statistical analyses for purposes such evaluating preexisting evidence and designing or executing clinical studies. R is a free software environment for statistical computing. R supports many statistical analysis functions, but does not incorporate a statistical graphical user interface (GUI). The R commander provides an easy-to-use basic-statistics GUI for R. However, the statistical function of the R commander is limited, especially in the field of biostatistics. Therefore, the author added several important statistical functions to the R commander and named it "EZR (Easy R)", which is now being distributed on the following website: http://www.jichi.ac.jp/saitama-sct/. EZR allows the application of statistical functions that are frequently used in clinical studies, such as survival analyses, including competing risk analyses and the use of time-dependent covariates and so on, by point-and-click access. In addition, by saving the script automatically created by EZR, users can learn R script writing, maintain the traceability of the analysis, and assure that the statistical process is overseen by a supervisor.

  2. SOCR: Statistics Online Computational Resource

    PubMed Central

    Dinov, Ivo D.

    2011-01-01

    The need for hands-on computer laboratory experience in undergraduate and graduate statistics education has been firmly established in the past decade. As a result a number of attempts have been undertaken to develop novel approaches for problem-driven statistical thinking, data analysis and result interpretation. In this paper we describe an integrated educational web-based framework for: interactive distribution modeling, virtual online probability experimentation, statistical data analysis, visualization and integration. Following years of experience in statistical teaching at all college levels using established licensed statistical software packages, like STATA, S-PLUS, R, SPSS, SAS, Systat, etc., we have attempted to engineer a new statistics education environment, the Statistics Online Computational Resource (SOCR). This resource performs many of the standard types of statistical analysis, much like other classical tools. In addition, it is designed in a plug-in object-oriented architecture and is completely platform independent, web-based, interactive, extensible and secure. Over the past 4 years we have tested, fine-tuned and reanalyzed the SOCR framework in many of our undergraduate and graduate probability and statistics courses and have evidence that SOCR resources build student’s intuition and enhance their learning. PMID:21451741

  3. Statistical methodology for the analysis of dye-switch microarray experiments

    PubMed Central

    Mary-Huard, Tristan; Aubert, Julie; Mansouri-Attia, Nadera; Sandra, Olivier; Daudin, Jean-Jacques

    2008-01-01

    Background In individually dye-balanced microarray designs, each biological sample is hybridized on two different slides, once with Cy3 and once with Cy5. While this strategy ensures an automatic correction of the gene-specific labelling bias, it also induces dependencies between log-ratio measurements that must be taken into account in the statistical analysis. Results We present two original statistical procedures for the statistical analysis of individually balanced designs. These procedures are compared with the usual ML and REML mixed model procedures proposed in most statistical toolboxes, on both simulated and real data. Conclusion The UP procedure we propose as an alternative to usual mixed model procedures is more efficient and significantly faster to compute. This result provides some useful guidelines for the analysis of complex designs. PMID:18271965

  4. 77 FR 1454 - Request for Nominations of Members To Serve on the Census Scientific Advisory Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ..., statistical analysis, survey methodology, geospatial analysis, econometrics, cognitive psychology, and... following disciplines: Demography, economics, geography, psychology, statistics, survey methodology, social... technical expertise in such areas as demography, economics, geography, psychology, statistics, survey...

  5. Pathway analysis with next-generation sequencing data.

    PubMed

    Zhao, Jinying; Zhu, Yun; Boerwinkle, Eric; Xiong, Momiao

    2015-04-01

    Although pathway analysis methods have been developed and successfully applied to association studies of common variants, the statistical methods for pathway-based association analysis of rare variants have not been well developed. Many investigators observed highly inflated false-positive rates and low power in pathway-based tests of association of rare variants. The inflated false-positive rates and low true-positive rates of the current methods are mainly due to their lack of ability to account for gametic phase disequilibrium. To overcome these serious limitations, we develop a novel statistic that is based on the smoothed functional principal component analysis (SFPCA) for pathway association tests with next-generation sequencing data. The developed statistic has the ability to capture position-level variant information and account for gametic phase disequilibrium. By intensive simulations, we demonstrate that the SFPCA-based statistic for testing pathway association with either rare or common or both rare and common variants has the correct type 1 error rates. Also the power of the SFPCA-based statistic and 22 additional existing statistics are evaluated. We found that the SFPCA-based statistic has a much higher power than other existing statistics in all the scenarios considered. To further evaluate its performance, the SFPCA-based statistic is applied to pathway analysis of exome sequencing data in the early-onset myocardial infarction (EOMI) project. We identify three pathways significantly associated with EOMI after the Bonferroni correction. In addition, our preliminary results show that the SFPCA-based statistic has much smaller P-values to identify pathway association than other existing methods.

  6. Improved Statistics for Genome-Wide Interaction Analysis

    PubMed Central

    Ueki, Masao; Cordell, Heather J.

    2012-01-01

    Recently, Wu and colleagues [1] proposed two novel statistics for genome-wide interaction analysis using case/control or case-only data. In computer simulations, their proposed case/control statistic outperformed competing approaches, including the fast-epistasis option in PLINK and logistic regression analysis under the correct model; however, reasons for its superior performance were not fully explored. Here we investigate the theoretical properties and performance of Wu et al.'s proposed statistics and explain why, in some circumstances, they outperform competing approaches. Unfortunately, we find minor errors in the formulae for their statistics, resulting in tests that have higher than nominal type 1 error. We also find minor errors in PLINK's fast-epistasis and case-only statistics, although theory and simulations suggest that these errors have only negligible effect on type 1 error. We propose adjusted versions of all four statistics that, both theoretically and in computer simulations, maintain correct type 1 error rates under the null hypothesis. We also investigate statistics based on correlation coefficients that maintain similar control of type 1 error. Although designed to test specifically for interaction, we show that some of these previously-proposed statistics can, in fact, be sensitive to main effects at one or both loci, particularly in the presence of linkage disequilibrium. We propose two new “joint effects” statistics that, provided the disease is rare, are sensitive only to genuine interaction effects. In computer simulations we find, in most situations considered, that highest power is achieved by analysis under the correct genetic model. Such an analysis is unachievable in practice, as we do not know this model. However, generally high power over a wide range of scenarios is exhibited by our joint effects and adjusted Wu statistics. We recommend use of these alternative or adjusted statistics and urge caution when using Wu et al.'s originally-proposed statistics, on account of the inflated error rate that can result. PMID:22496670

  7. Statistics 101 for Radiologists.

    PubMed

    Anvari, Arash; Halpern, Elkan F; Samir, Anthony E

    2015-10-01

    Diagnostic tests have wide clinical applications, including screening, diagnosis, measuring treatment effect, and determining prognosis. Interpreting diagnostic test results requires an understanding of key statistical concepts used to evaluate test efficacy. This review explains descriptive statistics and discusses probability, including mutually exclusive and independent events and conditional probability. In the inferential statistics section, a statistical perspective on study design is provided, together with an explanation of how to select appropriate statistical tests. Key concepts in recruiting study samples are discussed, including representativeness and random sampling. Variable types are defined, including predictor, outcome, and covariate variables, and the relationship of these variables to one another. In the hypothesis testing section, we explain how to determine if observed differences between groups are likely to be due to chance. We explain type I and II errors, statistical significance, and study power, followed by an explanation of effect sizes and how confidence intervals can be used to generalize observed effect sizes to the larger population. Statistical tests are explained in four categories: t tests and analysis of variance, proportion analysis tests, nonparametric tests, and regression techniques. We discuss sensitivity, specificity, accuracy, receiver operating characteristic analysis, and likelihood ratios. Measures of reliability and agreement, including κ statistics, intraclass correlation coefficients, and Bland-Altman graphs and analysis, are introduced. © RSNA, 2015.

  8. Linkage analysis of systolic blood pressure: a score statistic and computer implementation

    PubMed Central

    Wang, Kai; Peng, Yingwei

    2003-01-01

    A genome-wide linkage analysis was conducted on systolic blood pressure using a score statistic. The randomly selected Replicate 34 of the simulated data was used. The score statistic was applied to the sibships derived from the general pedigrees. An add-on R program to GENEHUNTER was developed for this analysis and is freely available. PMID:14975145

  9. The Shock and Vibration Digest. Volume 16, Number 1

    DTIC Science & Technology

    1984-01-01

    investigation of the measure- ment of frequency band average loss factors of structural components for use in the statistical energy analysis method of...stiffness. Matrix methods Key Words: Finite element technique. Statistical energy analysis . Experimental techniques. Framed structures, Com- puter...programs In order to further understand the practical application of the statistical energy analysis , a two section plate-like frame structure is

  10. Normality Tests for Statistical Analysis: A Guide for Non-Statisticians

    PubMed Central

    Ghasemi, Asghar; Zahediasl, Saleh

    2012-01-01

    Statistical errors are common in scientific literature and about 50% of the published articles have at least one error. The assumption of normality needs to be checked for many statistical procedures, namely parametric tests, because their validity depends on it. The aim of this commentary is to overview checking for normality in statistical analysis using SPSS. PMID:23843808

  11. Recent statistical methods for orientation data

    NASA Technical Reports Server (NTRS)

    Batschelet, E.

    1972-01-01

    The application of statistical methods for determining the areas of animal orientation and navigation are discussed. The method employed is limited to the two-dimensional case. Various tests for determining the validity of the statistical analysis are presented. Mathematical models are included to support the theoretical considerations and tables of data are developed to show the value of information obtained by statistical analysis.

  12. How Much Math Do Students Need to Succeed in Business and Economics Statistics? An Ordered Probit Analysis

    ERIC Educational Resources Information Center

    Green, Jeffrey J.; Stone, Courtenay C.; Zegeye, Abera; Charles, Thomas A.

    2009-01-01

    Because statistical analysis requires the ability to use mathematics, students typically are required to take one or more prerequisite math courses prior to enrolling in the business statistics course. Despite these math prerequisites, however, many students find it difficult to learn business statistics. In this study, we use an ordered probit…

  13. Common pitfalls in statistical analysis: “P” values, statistical significance and confidence intervals

    PubMed Central

    Ranganathan, Priya; Pramesh, C. S.; Buyse, Marc

    2015-01-01

    In the second part of a series on pitfalls in statistical analysis, we look at various ways in which a statistically significant study result can be expressed. We debunk some of the myths regarding the ‘P’ value, explain the importance of ‘confidence intervals’ and clarify the importance of including both values in a paper PMID:25878958

  14. [Review of research design and statistical methods in Chinese Journal of Cardiology].

    PubMed

    Zhang, Li-jun; Yu, Jin-ming

    2009-07-01

    To evaluate the research design and the use of statistical methods in Chinese Journal of Cardiology. Peer through the research design and statistical methods in all of the original papers in Chinese Journal of Cardiology from December 2007 to November 2008. The most frequently used research designs are cross-sectional design (34%), prospective design (21%) and experimental design (25%). In all of the articles, 49 (25%) use wrong statistical methods, 29 (15%) lack some sort of statistic analysis, 23 (12%) have inconsistencies in description of methods. There are significant differences between different statistical methods (P < 0.001). The correction rates of multifactor analysis were low and repeated measurement datas were not used repeated measurement analysis. Many problems exist in Chinese Journal of Cardiology. Better research design and correct use of statistical methods are still needed. More strict review by statistician and epidemiologist is also required to improve the literature qualities.

  15. The statistical analysis of global climate change studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.W.

    1992-01-01

    The focus of this work is to contribute to the enhancement of the relationship between climatologists and statisticians. The analysis of global change data has been underway for many years by atmospheric scientists. Much of this analysis includes a heavy reliance on statistics and statistical inference. Some specific climatological analyses are presented and the dependence on statistics is documented before the analysis is undertaken. The first problem presented involves the fluctuation-dissipation theorem and its application to global climate models. This problem has a sound theoretical niche in the literature of both climate modeling and physics, but a statistical analysis inmore » which the data is obtained from the model to show graphically the relationship has not been undertaken. It is under this motivation that the author presents this problem. A second problem concerning the standard errors in estimating global temperatures is purely statistical in nature although very little materials exists for sampling on such a frame. This problem not only has climatological and statistical ramifications, but political ones as well. It is planned to use these results in a further analysis of global warming using actual data collected on the earth. In order to simplify the analysis of these problems, the development of a computer program, MISHA, is presented. This interactive program contains many of the routines, functions, graphics, and map projections needed by the climatologist in order to effectively enter the arena of data visualization.« less

  16. Statistical Reform in School Psychology Research: A Synthesis

    ERIC Educational Resources Information Center

    Swaminathan, Hariharan; Rogers, H. Jane

    2007-01-01

    Statistical reform in school psychology research is discussed in terms of research designs, measurement issues, statistical modeling and analysis procedures, interpretation and reporting of statistical results, and finally statistics education.

  17. Parallel auto-correlative statistics with VTK.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pebay, Philippe Pierre; Bennett, Janine Camille

    2013-08-01

    This report summarizes existing statistical engines in VTK and presents both the serial and parallel auto-correlative statistics engines. It is a sequel to [PT08, BPRT09b, PT09, BPT09, PT10] which studied the parallel descriptive, correlative, multi-correlative, principal component analysis, contingency, k-means, and order statistics engines. The ease of use of the new parallel auto-correlative statistics engine is illustrated by the means of C++ code snippets and algorithm verification is provided. This report justifies the design of the statistics engines with parallel scalability in mind, and provides scalability and speed-up analysis results for the autocorrelative statistics engine.

  18. Numerical Analysis of Stochastic Dynamical Systems in the Medium-Frequency Range

    DTIC Science & Technology

    2003-02-01

    frequency vibration analysis such as the statistical energy analysis (SEA), the traditional modal analysis (well-suited for high and low: frequency...that the first few structural normal modes primarily constitute the total response. In the higher frequency range, the statistical energy analysis (SEA

  19. TRAPR: R Package for Statistical Analysis and Visualization of RNA-Seq Data.

    PubMed

    Lim, Jae Hyun; Lee, Soo Youn; Kim, Ju Han

    2017-03-01

    High-throughput transcriptome sequencing, also known as RNA sequencing (RNA-Seq), is a standard technology for measuring gene expression with unprecedented accuracy. Numerous bioconductor packages have been developed for the statistical analysis of RNA-Seq data. However, these tools focus on specific aspects of the data analysis pipeline, and are difficult to appropriately integrate with one another due to their disparate data structures and processing methods. They also lack visualization methods to confirm the integrity of the data and the process. In this paper, we propose an R-based RNA-Seq analysis pipeline called TRAPR, an integrated tool that facilitates the statistical analysis and visualization of RNA-Seq expression data. TRAPR provides various functions for data management, the filtering of low-quality data, normalization, transformation, statistical analysis, data visualization, and result visualization that allow researchers to build customized analysis pipelines.

  20. Exploratory Visual Analysis of Statistical Results from Microarray Experiments Comparing High and Low Grade Glioma

    PubMed Central

    Reif, David M.; Israel, Mark A.; Moore, Jason H.

    2007-01-01

    The biological interpretation of gene expression microarray results is a daunting challenge. For complex diseases such as cancer, wherein the body of published research is extensive, the incorporation of expert knowledge provides a useful analytical framework. We have previously developed the Exploratory Visual Analysis (EVA) software for exploring data analysis results in the context of annotation information about each gene, as well as biologically relevant groups of genes. We present EVA as a flexible combination of statistics and biological annotation that provides a straightforward visual interface for the interpretation of microarray analyses of gene expression in the most commonly occuring class of brain tumors, glioma. We demonstrate the utility of EVA for the biological interpretation of statistical results by analyzing publicly available gene expression profiles of two important glial tumors. The results of a statistical comparison between 21 malignant, high-grade glioblastoma multiforme (GBM) tumors and 19 indolent, low-grade pilocytic astrocytomas were analyzed using EVA. By using EVA to examine the results of a relatively simple statistical analysis, we were able to identify tumor class-specific gene expression patterns having both statistical and biological significance. Our interactive analysis highlighted the potential importance of genes involved in cell cycle progression, proliferation, signaling, adhesion, migration, motility, and structure, as well as candidate gene loci on a region of Chromosome 7 that has been implicated in glioma. Because EVA does not require statistical or computational expertise and has the flexibility to accommodate any type of statistical analysis, we anticipate EVA will prove a useful addition to the repertoire of computational methods used for microarray data analysis. EVA is available at no charge to academic users and can be found at http://www.epistasis.org. PMID:19390666

  1. A new u-statistic with superior design sensitivity in matched observational studies.

    PubMed

    Rosenbaum, Paul R

    2011-09-01

    In an observational or nonrandomized study of treatment effects, a sensitivity analysis indicates the magnitude of bias from unmeasured covariates that would need to be present to alter the conclusions of a naïve analysis that presumes adjustments for observed covariates suffice to remove all bias. The power of sensitivity analysis is the probability that it will reject a false hypothesis about treatment effects allowing for a departure from random assignment of a specified magnitude; in particular, if this specified magnitude is "no departure" then this is the same as the power of a randomization test in a randomized experiment. A new family of u-statistics is proposed that includes Wilcoxon's signed rank statistic but also includes other statistics with substantially higher power when a sensitivity analysis is performed in an observational study. Wilcoxon's statistic has high power to detect small effects in large randomized experiments-that is, it often has good Pitman efficiency-but small effects are invariably sensitive to small unobserved biases. Members of this family of u-statistics that emphasize medium to large effects can have substantially higher power in a sensitivity analysis. For example, in one situation with 250 pair differences that are Normal with expectation 1/2 and variance 1, the power of a sensitivity analysis that uses Wilcoxon's statistic is 0.08 while the power of another member of the family of u-statistics is 0.66. The topic is examined by performing a sensitivity analysis in three observational studies, using an asymptotic measure called the design sensitivity, and by simulating power in finite samples. The three examples are drawn from epidemiology, clinical medicine, and genetic toxicology. © 2010, The International Biometric Society.

  2. The Statistical Consulting Center for Astronomy (SCCA)

    NASA Technical Reports Server (NTRS)

    Akritas, Michael

    2001-01-01

    The process by which raw astronomical data acquisition is transformed into scientifically meaningful results and interpretation typically involves many statistical steps. Traditional astronomy limits itself to a narrow range of old and familiar statistical methods: means and standard deviations; least-squares methods like chi(sup 2) minimization; and simple nonparametric procedures such as the Kolmogorov-Smirnov tests. These tools are often inadequate for the complex problems and datasets under investigations, and recent years have witnessed an increased usage of maximum-likelihood, survival analysis, multivariate analysis, wavelet and advanced time-series methods. The Statistical Consulting Center for Astronomy (SCCA) assisted astronomers with the use of sophisticated tools, and to match these tools with specific problems. The SCCA operated with two professors of statistics and a professor of astronomy working together. Questions were received by e-mail, and were discussed in detail with the questioner. Summaries of those questions and answers leading to new approaches were posted on the Web (www.state.psu.edu/ mga/SCCA). In addition to serving individual astronomers, the SCCA established a Web site for general use that provides hypertext links to selected on-line public-domain statistical software and services. The StatCodes site (www.astro.psu.edu/statcodes) provides over 200 links in the areas of: Bayesian statistics; censored and truncated data; correlation and regression, density estimation and smoothing, general statistics packages and information; image analysis; interactive Web tools; multivariate analysis; multivariate clustering and classification; nonparametric analysis; software written by astronomers; spatial statistics; statistical distributions; time series analysis; and visualization tools. StatCodes has received a remarkable high and constant hit rate of 250 hits/week (over 10,000/year) since its inception in mid-1997. It is of interest to scientists both within and outside of astronomy. The most popular sections are multivariate techniques, image analysis, and time series analysis. Hundreds of copies of the ASURV, SLOPES and CENS-TAU codes developed by SCCA scientists were also downloaded from the StatCodes site. In addition to formal SCCA duties, SCCA scientists continued a variety of related activities in astrostatistics, including refereeing of statistically oriented papers submitted to the Astrophysical Journal, talks in meetings including Feigelson's talk to science journalists entitled "The reemergence of astrostatistics" at the American Association for the Advancement of Science meeting, and published papers of astrostatistical content.

  3. Statistical Analysis of Research Data | Center for Cancer Research

    Cancer.gov

    Recent advances in cancer biology have resulted in the need for increased statistical analysis of research data. The Statistical Analysis of Research Data (SARD) course will be held on April 5-6, 2018 from 9 a.m.-5 p.m. at the National Institutes of Health's Natcher Conference Center, Balcony C on the Bethesda Campus. SARD is designed to provide an overview on the general

  4. The Shock and Vibration Digest. Volume 16, Number 3

    DTIC Science & Technology

    1984-03-01

    Fluid-induced Statistical Energy Analysis Method excitation, Wind tunnel testing V.R. Miller and L.L. Faulkner Flight Dynamics Lab., Air Force...84475 wall by the statistical energy analysis (SEA) method. The fuselage structure is represented as a series of curved, iso- Probabilistic Fracture...heavy are demonstrated in three-dimensional form. floor, a statistical energy analysis (SEA) model is presented. Only structural systems (i.e., no

  5. TSP Symposium 2012 Proceedings

    DTIC Science & Technology

    2012-11-01

    and Statistical Model 78 7.3 Analysis and Results 79 7.4 Threats to Validity and Limitations 85 7.5 Conclusions 86 7.6 Acknowledgments 87 7.7...Table 12: Overall Statistics of the Experiment 32 Table 13: Results of Pairwise ANOVA Analysis, Highlighting Statistically Significant Differences...we calculated the percentage of defects injected. The distribution statistics are shown in Table 2. Table 2: Mean Lower, Upper Confidence Interval

  6. Applying Regression Analysis to Problems in Institutional Research.

    ERIC Educational Resources Information Center

    Bohannon, Tom R.

    1988-01-01

    Regression analysis is one of the most frequently used statistical techniques in institutional research. Principles of least squares, model building, residual analysis, influence statistics, and multi-collinearity are described and illustrated. (Author/MSE)

  7. Diagnosis checking of statistical analysis in RCTs indexed in PubMed.

    PubMed

    Lee, Paul H; Tse, Andy C Y

    2017-11-01

    Statistical analysis is essential for reporting of the results of randomized controlled trials (RCTs), as well as evaluating their effectiveness. However, the validity of a statistical analysis also depends on whether the assumptions of that analysis are valid. To review all RCTs published in journals indexed in PubMed during December 2014 to provide a complete picture of how RCTs handle assumptions of statistical analysis. We reviewed all RCTs published in December 2014 that appeared in journals indexed in PubMed using the Cochrane highly sensitive search strategy. The 2014 impact factors of the journals were used as proxies for their quality. The type of statistical analysis used and whether the assumptions of the analysis were tested were reviewed. In total, 451 papers were included. Of the 278 papers that reported a crude analysis for the primary outcomes, 31 (27·2%) reported whether the outcome was normally distributed. Of the 172 papers that reported an adjusted analysis for the primary outcomes, diagnosis checking was rarely conducted, with only 20%, 8·6% and 7% checked for generalized linear model, Cox proportional hazard model and multilevel model, respectively. Study characteristics (study type, drug trial, funding sources, journal type and endorsement of CONSORT guidelines) were not associated with the reporting of diagnosis checking. The diagnosis of statistical analyses in RCTs published in PubMed-indexed journals was usually absent. Journals should provide guidelines about the reporting of a diagnosis of assumptions. © 2017 Stichting European Society for Clinical Investigation Journal Foundation.

  8. A Survey of Probabilistic Methods for Dynamical Systems with Uncertain Parameters.

    DTIC Science & Technology

    1986-05-01

    J., "An Approach to the Theoretical Background of Statistical Energy Analysis Applied to Structural Vibration," Journ. Acoust. Soc. Amer., Vol. 69...1973, Sect. 8.3. 80. Lyon, R.H., " Statistical Energy Analysis of Dynamical Systems," M.I.T. Press, 1975. e) Late References added in Proofreading !! 81...Dowell, E.H., and Kubota, Y., "Asymptotic Modal Analysis and ’~ y C-" -165- Statistical Energy Analysis of Dynamical Systems," Journ. Appi. - Mech

  9. Proceedings of the NASTRAN (Tradename) Users’ Colloquium (17th) Held in San Antonio, Texas on 24-28 April 1989

    DTIC Science & Technology

    1989-03-01

    statistical energy analysis , the finite clement method, and the power flow method. Experimental solutions are the most common in the literature. The authors of...to the added weights and inertias of the transducers attached to an experimental structure. Statistical energy analysis (SEA) is a computational method...Analysis and Diagnosis," Journal of Sound and Vibration, Vol. 115, No. 3, pp. 405-422 (1987). 8. Lyon, R.L., Statistical Energy Analysis of Dynamical Systems

  10. The Ontology of Biological and Clinical Statistics (OBCS) for standardized and reproducible statistical analysis.

    PubMed

    Zheng, Jie; Harris, Marcelline R; Masci, Anna Maria; Lin, Yu; Hero, Alfred; Smith, Barry; He, Yongqun

    2016-09-14

    Statistics play a critical role in biological and clinical research. However, most reports of scientific results in the published literature make it difficult for the reader to reproduce the statistical analyses performed in achieving those results because they provide inadequate documentation of the statistical tests and algorithms applied. The Ontology of Biological and Clinical Statistics (OBCS) is put forward here as a step towards solving this problem. The terms in OBCS including 'data collection', 'data transformation in statistics', 'data visualization', 'statistical data analysis', and 'drawing a conclusion based on data', cover the major types of statistical processes used in basic biological research and clinical outcome studies. OBCS is aligned with the Basic Formal Ontology (BFO) and extends the Ontology of Biomedical Investigations (OBI), an OBO (Open Biological and Biomedical Ontologies) Foundry ontology supported by over 20 research communities. Currently, OBCS comprehends 878 terms, representing 20 BFO classes, 403 OBI classes, 229 OBCS specific classes, and 122 classes imported from ten other OBO ontologies. We discuss two examples illustrating how the ontology is being applied. In the first (biological) use case, we describe how OBCS was applied to represent the high throughput microarray data analysis of immunological transcriptional profiles in human subjects vaccinated with an influenza vaccine. In the second (clinical outcomes) use case, we applied OBCS to represent the processing of electronic health care data to determine the associations between hospital staffing levels and patient mortality. Our case studies were designed to show how OBCS can be used for the consistent representation of statistical analysis pipelines under two different research paradigms. Other ongoing projects using OBCS for statistical data processing are also discussed. The OBCS source code and documentation are available at: https://github.com/obcs/obcs . The Ontology of Biological and Clinical Statistics (OBCS) is a community-based open source ontology in the domain of biological and clinical statistics. OBCS is a timely ontology that represents statistics-related terms and their relations in a rigorous fashion, facilitates standard data analysis and integration, and supports reproducible biological and clinical research.

  11. [Methods of statistical analysis in differential diagnostics of the degree of brain glioma anaplasia during preoperative stage].

    PubMed

    Glavatskiĭ, A Ia; Guzhovskaia, N V; Lysenko, S N; Kulik, A V

    2005-12-01

    The authors proposed a possible preoperative diagnostics of the degree of supratentorial brain gliom anaplasia using statistical analysis methods. It relies on a complex examination of 934 patients with I-IV degree anaplasias, which had been treated in the Institute of Neurosurgery from 1990 to 2004. The use of statistical analysis methods for differential diagnostics of the degree of brain gliom anaplasia may optimize a diagnostic algorithm, increase reliability of obtained data and in some cases avoid carrying out irrational operative intrusions. Clinically important signs for the use of statistical analysis methods directed to preoperative diagnostics of brain gliom anaplasia have been defined

  12. 75 FR 72611 - Assessments, Large Bank Pricing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-24

    ... the worst risk ranking and are included in the statistical analysis. Appendix 1 to the NPR describes the statistical analysis in detail. \\12\\ The percentage approximated by factors is based on the statistical model for that particual year. Actual weights assigned to each scorecard measure are largely based...

  13. Online Statistical Modeling (Regression Analysis) for Independent Responses

    NASA Astrophysics Data System (ADS)

    Made Tirta, I.; Anggraeni, Dian; Pandutama, Martinus

    2017-06-01

    Regression analysis (statistical analmodelling) are among statistical methods which are frequently needed in analyzing quantitative data, especially to model relationship between response and explanatory variables. Nowadays, statistical models have been developed into various directions to model various type and complex relationship of data. Rich varieties of advanced and recent statistical modelling are mostly available on open source software (one of them is R). However, these advanced statistical modelling, are not very friendly to novice R users, since they are based on programming script or command line interface. Our research aims to developed web interface (based on R and shiny), so that most recent and advanced statistical modelling are readily available, accessible and applicable on web. We have previously made interface in the form of e-tutorial for several modern and advanced statistical modelling on R especially for independent responses (including linear models/LM, generalized linier models/GLM, generalized additive model/GAM and generalized additive model for location scale and shape/GAMLSS). In this research we unified them in the form of data analysis, including model using Computer Intensive Statistics (Bootstrap and Markov Chain Monte Carlo/ MCMC). All are readily accessible on our online Virtual Statistics Laboratory. The web (interface) make the statistical modeling becomes easier to apply and easier to compare them in order to find the most appropriate model for the data.

  14. Research design and statistical methods in Pakistan Journal of Medical Sciences (PJMS).

    PubMed

    Akhtar, Sohail; Shah, Syed Wadood Ali; Rafiq, M; Khan, Ajmal

    2016-01-01

    This article compares the study design and statistical methods used in 2005, 2010 and 2015 of Pakistan Journal of Medical Sciences (PJMS). Only original articles of PJMS were considered for the analysis. The articles were carefully reviewed for statistical methods and designs, and then recorded accordingly. The frequency of each statistical method and research design was estimated and compared with previous years. A total of 429 articles were evaluated (n=74 in 2005, n=179 in 2010, n=176 in 2015) in which 171 (40%) were cross-sectional and 116 (27%) were prospective study designs. A verity of statistical methods were found in the analysis. The most frequent methods include: descriptive statistics (n=315, 73.4%), chi-square/Fisher's exact tests (n=205, 47.8%) and student t-test (n=186, 43.4%). There was a significant increase in the use of statistical methods over time period: t-test, chi-square/Fisher's exact test, logistic regression, epidemiological statistics, and non-parametric tests. This study shows that a diverse variety of statistical methods have been used in the research articles of PJMS and frequency improved from 2005 to 2015. However, descriptive statistics was the most frequent method of statistical analysis in the published articles while cross-sectional study design was common study design.

  15. Statistical properties of filtered pseudorandom digital sequences formed from the sum of maximum-length sequences

    NASA Technical Reports Server (NTRS)

    Wallace, G. R.; Weathers, G. D.; Graf, E. R.

    1973-01-01

    The statistics of filtered pseudorandom digital sequences called hybrid-sum sequences, formed from the modulo-two sum of several maximum-length sequences, are analyzed. The results indicate that a relation exists between the statistics of the filtered sequence and the characteristic polynomials of the component maximum length sequences. An analysis procedure is developed for identifying a large group of sequences with good statistical properties for applications requiring the generation of analog pseudorandom noise. By use of the analysis approach, the filtering process is approximated by the convolution of the sequence with a sum of unit step functions. A parameter reflecting the overall statistical properties of filtered pseudorandom sequences is derived. This parameter is called the statistical quality factor. A computer algorithm to calculate the statistical quality factor for the filtered sequences is presented, and the results for two examples of sequence combinations are included. The analysis reveals that the statistics of the signals generated with the hybrid-sum generator are potentially superior to the statistics of signals generated with maximum-length generators. Furthermore, fewer calculations are required to evaluate the statistics of a large group of hybrid-sum generators than are required to evaluate the statistics of the same size group of approximately equivalent maximum-length sequences.

  16. A critique of Rasch residual fit statistics.

    PubMed

    Karabatsos, G

    2000-01-01

    In test analysis involving the Rasch model, a large degree of importance is placed on the "objective" measurement of individual abilities and item difficulties. The degree to which the objectivity properties are attained, of course, depends on the degree to which the data fit the Rasch model. It is therefore important to utilize fit statistics that accurately and reliably detect the person-item response inconsistencies that threaten the measurement objectivity of persons and items. Given this argument, it is somewhat surprising that there is far more emphasis placed in the objective measurement of person and items than there is in the measurement quality of Rasch fit statistics. This paper provides a critical analysis of the residual fit statistics of the Rasch model, arguably the most often used fit statistics, in an effort to illustrate that the task of Rasch fit analysis is not as simple and straightforward as it appears to be. The faulty statistical properties of the residual fit statistics do not allow either a convenient or a straightforward approach to Rasch fit analysis. For instance, given a residual fit statistic, the use of a single minimum critical value for misfit diagnosis across different testing situations, where the situations vary in sample and test properties, leads to both the overdetection and underdetection of misfit. To improve this situation, it is argued that psychometricians need to implement residual-free Rasch fit statistics that are based on the number of Guttman response errors, or use indices that are statistically optimal in detecting measurement disturbances.

  17. Linearised and non-linearised isotherm models optimization analysis by error functions and statistical means

    PubMed Central

    2014-01-01

    In adsorption study, to describe sorption process and evaluation of best-fitting isotherm model is a key analysis to investigate the theoretical hypothesis. Hence, numerous statistically analysis have been extensively used to estimate validity of the experimental equilibrium adsorption values with the predicted equilibrium values. Several statistical error analysis were carried out. In the present study, the following statistical analysis were carried out to evaluate the adsorption isotherm model fitness, like the Pearson correlation, the coefficient of determination and the Chi-square test, have been used. The ANOVA test was carried out for evaluating significance of various error functions and also coefficient of dispersion were evaluated for linearised and non-linearised models. The adsorption of phenol onto natural soil (Local name Kalathur soil) was carried out, in batch mode at 30 ± 20 C. For estimating the isotherm parameters, to get a holistic view of the analysis the models were compared between linear and non-linear isotherm models. The result reveled that, among above mentioned error functions and statistical functions were designed to determine the best fitting isotherm. PMID:25018878

  18. Meta- and statistical analysis of single-case intervention research data: quantitative gifts and a wish list.

    PubMed

    Kratochwill, Thomas R; Levin, Joel R

    2014-04-01

    In this commentary, we add to the spirit of the articles appearing in the special series devoted to meta- and statistical analysis of single-case intervention-design data. Following a brief discussion of historical factors leading to our initial involvement in statistical analysis of such data, we discuss: (a) the value added by including statistical-analysis recommendations in the What Works Clearinghouse Standards for single-case intervention designs; (b) the importance of visual analysis in single-case intervention research, along with the distinctive role that could be played by single-case effect-size measures; and (c) the elevated internal validity and statistical-conclusion validity afforded by the incorporation of various forms of randomization into basic single-case design structures. For the future, we envision more widespread application of quantitative analyses, as critical adjuncts to visual analysis, in both primary single-case intervention research studies and literature reviews in the behavioral, educational, and health sciences. Copyright © 2014 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  19. Randomization Procedures Applied to Analysis of Ballistic Data

    DTIC Science & Technology

    1991-06-01

    test,;;15. NUMBER OF PAGES data analysis; computationally intensive statistics ; randomization tests; permutation tests; 16 nonparametric statistics ...be 0.13. 8 Any reasonable statistical procedure would fail to support the notion of improvement of dynamic over standard indexing based on this data ...AD-A238 389 TECHNICAL REPORT BRL-TR-3245 iBRL RANDOMIZATION PROCEDURES APPLIED TO ANALYSIS OF BALLISTIC DATA MALCOLM S. TAYLOR BARRY A. BODT - JUNE

  20. The Shock and Vibration Digest. Volume 15. Number 1

    DTIC Science & Technology

    1983-01-01

    acoustics The books are arranged to engineer is statistical energy analysis (SEA). This show the wealth of information that exists and the concept is...is also used for vibrating systems in pie nonlinear elements. However, for systems with a which statistical energy analysis and power flow continuous... statistical energy analysis to analyze the random nonlinear algebraic equations can be difficult. response of two identical subsystems coupled at an end

  1. Research of Extension of the Life Cycle of Helicopter Rotor Blade in Hungary

    DTIC Science & Technology

    2003-02-01

    Radiography (DXR), and (iii) Vibration Diagnostics (VD) with Statistical Energy Analysis (SEA) were semi- simultaneously applied [1]. The used three...2.2. Vibration Diagnostics (VD)) Parallel to the NDT measurements the Statistical Energy Analysis (SEA) as a vibration diagnostical tool were...noises were analysed with a dual-channel real time frequency analyser (BK2035). In addition to the Statistical Energy Analysis measurement a small

  2. The Shock and Vibration Digest, Volume 14, Number 2, February 1982

    DTIC Science & Technology

    1982-02-01

    figurations. 75 4J DUCTS 82-424 (Also see No. 346) Coupling Lou Factors for Statistical Energy Analysis of Sound Transnission at Rectangular...waves, Sound waves, Wave props- tures by means of statistical energy analysis (SEA) coupling gation loss factors for the structure-borne sound...multilayered panels are discussed. Statistical energy analysis (SEA) has proved to be a promising Experimental results of stiffened panels, damping tape

  3. Optimal Regulation of Structural Systems with Uncertain Parameters.

    DTIC Science & Technology

    1981-02-02

    been addressed, in part, by Statistical Energy Analysis . Moti- vated by a concern with high frequency vibration and acoustical- structural...Parameter Systems," AFOSR-TR-79-0753 (May, 1979). 25. R. H. Lyon, Statistical Energy Analysis of Dynamical Systems: Theory and Applications, (M.I.T...Press, Cambridge, Mass., 1975). 26. E. E. Ungar, " Statistical Energy Analysis of Vibrating Systems," Trans. ASME, J. Eng. Ind. 89, 626 (1967). 139 27

  4. The Shock and Vibration Digest. Volume 14, Number 8

    DTIC Science & Technology

    1982-08-01

    generating interest in averaged transfer functions. Broadband transfer functions are derived using the methods of statistical energy analysis (SEA...Accelerometer, Endevco Corp., San Juan Capis- trano,CA(1982). 7. Lyon, R.H., Statistical Energy Analysis of Dy- namical Systems, MIT Press, Cambridge, MA...A fairly new technique known as statistical energy analysis , or SEA, [35-44] has been useful for many problems of noise transmission. The difficulty

  5. The Shock and Vibration Digest, Volume 17, Number 8

    DTIC Science & Technology

    1985-08-01

    ate, transmit, and radiate audible sound. dures are based on acoustic power flow, statistical energy analysis (SEA), and modal methods [22-283. A...modified partition area. features of the acoustic field. I.--1 85-1642 Statistical Energy Analysis , Structural Reso- nances, and Beam Networks BUILDING...energy methods, Structural resonance L.J. Lee Heriot-Watt Univ., Chambers St., Edinburgh The statistical energy analysis method is EHI 1HX, Scotland

  6. How Many Studies Do You Need? A Primer on Statistical Power for Meta-Analysis

    ERIC Educational Resources Information Center

    Valentine, Jeffrey C.; Pigott, Therese D.; Rothstein, Hannah R.

    2010-01-01

    In this article, the authors outline methods for using fixed and random effects power analysis in the context of meta-analysis. Like statistical power analysis for primary studies, power analysis for meta-analysis can be done either prospectively or retrospectively and requires assumptions about parameters that are unknown. The authors provide…

  7. Explorations in Statistics: The Analysis of Change

    ERIC Educational Resources Information Center

    Curran-Everett, Douglas; Williams, Calvin L.

    2015-01-01

    Learning about statistics is a lot like learning about science: the learning is more meaningful if you can actively explore. This tenth installment of "Explorations in Statistics" explores the analysis of a potential change in some physiological response. As researchers, we often express absolute change as percent change so we can…

  8. Measuring the Success of an Academic Development Programme: A Statistical Analysis

    ERIC Educational Resources Information Center

    Smith, L. C.

    2009-01-01

    This study uses statistical analysis to estimate the impact of first-year academic development courses in microeconomics, statistics, accountancy, and information systems, offered by the University of Cape Town's Commerce Academic Development Programme, on students' graduation performance relative to that achieved by mainstream students. The data…

  9. 75 FR 24718 - Guidance for Industry on Documenting Statistical Analysis Programs and Data Files; Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ...] Guidance for Industry on Documenting Statistical Analysis Programs and Data Files; Availability AGENCY... Programs and Data Files.'' This guidance is provided to inform study statisticians of recommendations for documenting statistical analyses and data files submitted to the Center for Veterinary Medicine (CVM) for the...

  10. Statistical Analysis For Nucleus/Nucleus Collisions

    NASA Technical Reports Server (NTRS)

    Mcguire, Stephen C.

    1989-01-01

    Report describes use of several statistical techniques to charactertize angular distributions of secondary particles emitted in collisions of atomic nuclei in energy range of 24 to 61 GeV per nucleon. Purpose of statistical analysis to determine correlations between intensities of emitted particles and angles comfirming existence of quark/gluon plasma.

  11. Statistical power analysis of cardiovascular safety pharmacology studies in conscious rats.

    PubMed

    Bhatt, Siddhartha; Li, Dingzhou; Flynn, Declan; Wisialowski, Todd; Hemkens, Michelle; Steidl-Nichols, Jill

    2016-01-01

    Cardiovascular (CV) toxicity and related attrition are a major challenge for novel therapeutic entities and identifying CV liability early is critical for effective derisking. CV safety pharmacology studies in rats are a valuable tool for early investigation of CV risk. Thorough understanding of data analysis techniques and statistical power of these studies is currently lacking and is imperative for enabling sound decision-making. Data from 24 crossover and 12 parallel design CV telemetry rat studies were used for statistical power calculations. Average values of telemetry parameters (heart rate, blood pressure, body temperature, and activity) were logged every 60s (from 1h predose to 24h post-dose) and reduced to 15min mean values. These data were subsequently binned into super intervals for statistical analysis. A repeated measure analysis of variance was used for statistical analysis of crossover studies and a repeated measure analysis of covariance was used for parallel studies. Statistical power analysis was performed to generate power curves and establish relationships between detectable CV (blood pressure and heart rate) changes and statistical power. Additionally, data from a crossover CV study with phentolamine at 4, 20 and 100mg/kg are reported as a representative example of data analysis methods. Phentolamine produced a CV profile characteristic of alpha adrenergic receptor antagonism, evidenced by a dose-dependent decrease in blood pressure and reflex tachycardia. Detectable blood pressure changes at 80% statistical power for crossover studies (n=8) were 4-5mmHg. For parallel studies (n=8), detectable changes at 80% power were 6-7mmHg. Detectable heart rate changes for both study designs were 20-22bpm. Based on our results, the conscious rat CV model is a sensitive tool to detect and mitigate CV risk in early safety studies. Furthermore, these results will enable informed selection of appropriate models and study design for early stage CV studies. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Statistics for nuclear engineers and scientists. Part 1. Basic statistical inference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beggs, W.J.

    1981-02-01

    This report is intended for the use of engineers and scientists working in the nuclear industry, especially at the Bettis Atomic Power Laboratory. It serves as the basis for several Bettis in-house statistics courses. The objectives of the report are to introduce the reader to the language and concepts of statistics and to provide a basic set of techniques to apply to problems of the collection and analysis of data. Part 1 covers subjects of basic inference. The subjects include: descriptive statistics; probability; simple inference for normally distributed populations, and for non-normal populations as well; comparison of two populations; themore » analysis of variance; quality control procedures; and linear regression analysis.« less

  13. The Empirical Review of Meta-Analysis Published in Korea

    ERIC Educational Resources Information Center

    Park, Sunyoung; Hong, Sehee

    2016-01-01

    Meta-analysis is a statistical method that is increasingly utilized to combine and compare the results of previous primary studies. However, because of the lack of comprehensive guidelines for how to use meta-analysis, many meta-analysis studies have failed to consider important aspects, such as statistical programs, power analysis, publication…

  14. Meta-Analysis for Primary and Secondary Data Analysis: The Super-Experiment Metaphor.

    ERIC Educational Resources Information Center

    Jackson, Sally

    1991-01-01

    Considers the relation between meta-analysis statistics and analysis of variance statistics. Discusses advantages and disadvantages as a primary data analysis tool. Argues that the two approaches are partial paraphrases of one another. Advocates an integrative approach that introduces the best of meta-analytic thinking into primary analysis…

  15. Progress of statistical analysis in biomedical research through the historical review of the development of the Framingham score.

    PubMed

    Ignjatović, Aleksandra; Stojanović, Miodrag; Milošević, Zoran; Anđelković Apostolović, Marija

    2017-12-02

    The interest in developing risk models in medicine not only is appealing, but also associated with many obstacles in different aspects of predictive model development. Initially, the association of biomarkers or the association of more markers with the specific outcome was proven by statistical significance, but novel and demanding questions required the development of new and more complex statistical techniques. Progress of statistical analysis in biomedical research can be observed the best through the history of the Framingham study and development of the Framingham score. Evaluation of predictive models comes from a combination of the facts which are results of several metrics. Using logistic regression and Cox proportional hazards regression analysis, the calibration test, and the ROC curve analysis should be mandatory and eliminatory, and the central place should be taken by some new statistical techniques. In order to obtain complete information related to the new marker in the model, recently, there is a recommendation to use the reclassification tables by calculating the net reclassification index and the integrated discrimination improvement. Decision curve analysis is a novel method for evaluating the clinical usefulness of a predictive model. It may be noted that customizing and fine-tuning of the Framingham risk score initiated the development of statistical analysis. Clinically applicable predictive model should be a trade-off between all abovementioned statistical metrics, a trade-off between calibration and discrimination, accuracy and decision-making, costs and benefits, and quality and quantity of patient's life.

  16. [Confidence interval or p-value--similarities and differences between two important methods of statistical inference of quantitative studies].

    PubMed

    Harari, Gil

    2014-01-01

    Statistic significance, also known as p-value, and CI (Confidence Interval) are common statistics measures and are essential for the statistical analysis of studies in medicine and life sciences. These measures provide complementary information about the statistical probability and conclusions regarding the clinical significance of study findings. This article is intended to describe the methodologies, compare between the methods, assert their suitability for the different needs of study results analysis and to explain situations in which each method should be used.

  17. CORSSA: The Community Online Resource for Statistical Seismicity Analysis

    USGS Publications Warehouse

    Michael, Andrew J.; Wiemer, Stefan

    2010-01-01

    Statistical seismology is the application of rigorous statistical methods to earthquake science with the goal of improving our knowledge of how the earth works. Within statistical seismology there is a strong emphasis on the analysis of seismicity data in order to improve our scientific understanding of earthquakes and to improve the evaluation and testing of earthquake forecasts, earthquake early warning, and seismic hazards assessments. Given the societal importance of these applications, statistical seismology must be done well. Unfortunately, a lack of educational resources and available software tools make it difficult for students and new practitioners to learn about this discipline. The goal of the Community Online Resource for Statistical Seismicity Analysis (CORSSA) is to promote excellence in statistical seismology by providing the knowledge and resources necessary to understand and implement the best practices, so that the reader can apply these methods to their own research. This introduction describes the motivation for and vision of CORRSA. It also describes its structure and contents.

  18. Analysis and interpretation of cost data in randomised controlled trials: review of published studies

    PubMed Central

    Barber, Julie A; Thompson, Simon G

    1998-01-01

    Objective To review critically the statistical methods used for health economic evaluations in randomised controlled trials where an estimate of cost is available for each patient in the study. Design Survey of published randomised trials including an economic evaluation with cost values suitable for statistical analysis; 45 such trials published in 1995 were identified from Medline. Main outcome measures The use of statistical methods for cost data was assessed in terms of the descriptive statistics reported, use of statistical inference, and whether the reported conclusions were justified. Results Although all 45 trials reviewed apparently had cost data for each patient, only 9 (20%) reported adequate measures of variability for these data and only 25 (56%) gave results of statistical tests or a measure of precision for the comparison of costs between the randomised groups. Only 16 (36%) of the articles gave conclusions which were justified on the basis of results presented in the paper. No paper reported sample size calculations for costs. Conclusions The analysis and interpretation of cost data from published trials reveal a lack of statistical awareness. Strong and potentially misleading conclusions about the relative costs of alternative therapies have often been reported in the absence of supporting statistical evidence. Improvements in the analysis and reporting of health economic assessments are urgently required. Health economic guidelines need to be revised to incorporate more detailed statistical advice. Key messagesHealth economic evaluations required for important healthcare policy decisions are often carried out in randomised controlled trialsA review of such published economic evaluations assessed whether statistical methods for cost outcomes have been appropriately used and interpretedFew publications presented adequate descriptive information for costs or performed appropriate statistical analysesIn at least two thirds of the papers, the main conclusions regarding costs were not justifiedThe analysis and reporting of health economic assessments within randomised controlled trials urgently need improving PMID:9794854

  19. Toward Automated Intraocular Laser Surgery Using a Handheld Micromanipulator

    PubMed Central

    Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2014-01-01

    This paper presents a technique for automated intraocular laser surgery using a handheld micromanipulator known as Micron. The novel handheld manipulator enables the automated scanning of a laser probe within a cylinder of 4 mm long and 4 mm in diameter. For the automation, the surface of the retina is reconstructed using a stereomicroscope, and then preplanned targets are placed on the surface. The laser probe is precisely located on the target via visual servoing of the aiming beam, while maintaining a specific distance above the surface. In addition, the system is capable of tracking the surface of the eye in order to compensate for any eye movement introduced during the operation. We compared the performance of the automated scanning using various control thresholds, in order to find the most effective threshold in terms of accuracy and speed. Given the selected threshold, we conducted the handheld operation above a fixed target surface. The average error and execution time are reduced by 63.6% and 28.5%, respectively, compared to the unaided trials. Finally, the automated laser photocoagulation was demonstrated also in an eye phantom, including compensation for the eye movement. PMID:25893135

  20. Root and canal morphology of mandibular third molars in an Iranian population.

    PubMed

    Kuzekanani, Maryam; Haghani, Jahangir; Nosrati, Hossein

    2012-01-01

    A through knowledge of the root canal morphology is required for successful endodontic ther-apy. The aim of this study was to investigate the root and canal morphology of mandibular third molars in Kerman, a prov-ince in southeast of Iran. One-hundred-fifty extracted mandibular third molars were collected randomly from different dental clinics in Kerman. The root canal anatomy and morphology of each tooth was carefully studied using a clearing tech-nique. Root number and morphology, number of canals per root, root canal configuration according to Vertucci classifica-tion, and incidence of dilacerated roots and C-shaped canals in mandibular third molars were evaluated under stereomicro-scope with ×2 to ×3 magnifications. From the total of 150 mandibular third molars studied, 21% had one root. The majority of teeth (73%) had two roots. 5.5% of the teeth had three roots. The incidence of C-shaped canal was 3.5% in this study and 8% of the teeth had at least one dilacerated root. Although root canal anatomy and morphology of mandibular third molars is very variable having two roots seems to be the normal anatomy for these teeth.

  1. Characterization and Beneficiation Studies of a Low Grade Bauxite Ore

    NASA Astrophysics Data System (ADS)

    Rao, D. S.; Das, B.

    2014-10-01

    A low grade bauxite sample of central India was thoroughly characterized with the help of stereomicroscope, reflected light microscope and electron microscope using QEMSCAN. A few hand picked samples were collected from different places of the mine and were subjected to geochemical characterization studies. The geochemical studies indicated that most of the samples contain high silica and low alumina, except a few which are high grade. Mineralogically the samples consist of bauxite (gibbsite and boehmite), ferruginous mineral phases (goethite and hematite), clay and silicate (quartz), and titanium bearing minerals like rutile and ilmenite. Majority of the gibbsite, boehmite and gibbsitic oolites contain clay, quartz and iron and titanium mineral phases within the sample as inclusions. The sample on an average contains 39.1 % Al2O3 and 12.3 % SiO2, and 20.08 % of Fe2O3. Beneficiation techniques like size classification, sorting, scrubbing, hydrocyclone and magnetic separation were employed to reduce the silica content suitable for Bayer process. The studies indicated that, 50 % by weight with 41 % Al2O3 containing less than 5 % SiO2 could be achieved. The finer sized sample after physical beneficiation still contains high silica due to complex mineralogical associations.

  2. A new laboratory cultivation of Paramecium bursaria using non-pathogenic bacteria strains.

    PubMed

    Bator, Tomasz

    2010-01-01

    In most studies dealing with the laboratory cultivation of paramecia (Paramecium bursaria), Klebsiella pneumoniae bacteria are used to inoculate the medium. However, Klebsiella pneumoniae is a typical pathogen, and its use is always associated with a risk of infection. The aim of the present research was to examine non-pathogenic bacteria strains as components of the medium for Paramecium bursaria. The paramecia were incubated on lettuce infusions bacterized with different bacteria strains: Bacillus subtilis DSM 10, Bacillus megaterium DSM 32, Escherichia coli DSM 498, Micrococcus luteus DSM 348. A strain derived from the natural habitat of Paramecium bursaria was used as the control one. Experiments were conducted under constant light and in the dark. Paramecia cells were counted under a stereomicroscope on consecutive days of incubation. The obtained results show that the most intensive growth of Paramecium bursaria occurs in the presence of Escherichia coli DSM 498. The use of this strain as a component of the medium allows one to obtain a high number of ciliates regardless of the light conditions. It can be concluded that the Paramecium bursaria cultivation procedure can be modified by using the non-pathogenic bacteria strain Escherichia coli DSM 498 instead of Klebsiella pneumoniae.

  3. Measuring the circular motion of small objects using laser stroboscopic images.

    PubMed

    Wang, Hairong; Fu, Y; Du, R

    2008-01-01

    Measuring the circular motion of a small object, including its displacement, speed, and acceleration, is a challenging task. This paper presents a new method for measuring repetitive and/or nonrepetitive, constant speed and/or variable speed circular motion using laser stroboscopic images. Under stroboscopic illumination, each image taken by an ordinary camera records multioutlines of an object in motion; hence, processing the stroboscopic image will be able to extract the motion information. We built an experiment apparatus consisting of a laser as the light source, a stereomicroscope to magnify the image, and a normal complementary metal oxide semiconductor camera to record the image. As the object is in motion, the stroboscopic illumination generates a speckle pattern on the object that can be recorded by the camera and analyzed by a computer. Experimental results indicate that the stroboscopic imaging is stable under various conditions. Moreover, the characteristics of the motion, including the displacement, the velocity, and the acceleration can be calculated based on the width of speckle marks, the illumination intensity, the duty cycle, and the sampling frequency. Compared with the popular high-speed camera method, the presented method may achieve the same measuring accuracy, but with much reduced cost and complexity.

  4. Effect of Quaternary Ammonium Salt on Shear Bond Strength of Orthodontic Brackets to Enamel

    PubMed Central

    Ghadirian, Hannaneh; Geramy, Allahyar; Najafi, Farhood; Heidari, Soolmaz

    2017-01-01

    Objectives: This study sought to assess the effect of quaternary ammonium salt (QAS) on shear bond strength of orthodontic brackets to enamel. Materials and Methods: In this in vitro experimental study, 0, 10, 20 and 30% concentrations of QAS were added to Transbond XT primer. Brackets were bonded to 60 premolar teeth using the afore-mentioned adhesive mixtures, and the shear bond strength of the four groups (n=15) was measured using a universal testing machine. After debonding, the adhesive remnant index (ARI) score was determined under a stereomicroscope. Data were analyzed using one-way ANOVA. Results: The mean and standard deviation of shear bond strength of the control and 10%, 20% and 30% groups were 23.54±6.31, 21.81±2.82, 20.83±8.35 and 22.91±5.66 MPa, respectively. No significant difference was noted in shear bond strength of the groups (P=0.83). Study groups were not different in terms of ARI scores (P=0.80). Conclusions: The results showed that addition of QAS to Transbond XT primer had no adverse effect on shear bond strength of orthodontic brackets. PMID:29167688

  5. Comparative evaluation of the amount of gingival displacement produced by three different gingival retraction systems: An in vivo study.

    PubMed

    Chaudhari, Jignesh; Prajapati, Paranjay; Patel, Jayanti; Sethuraman, Rajesh; Naveen, Y G

    2015-01-01

    Tetrahydrozoline has been introduced as new gingival retraction agent but its clinical efficacy with widely used conventional retraction agents has not been tested. The study was designed to clinically evaluate efficacy of newer retraction agent tetrahydrozoline with two widely used retraction systems i.e., Expasyl retraction system and medicated retraction cords on basis of amount of gingival retraction. 30 subjects were selected according to inclusion and exclusion criteria. Maxillary Impressions were made with irreversible hydrocolloid for all subjects. Tray material was used for making the special tray. Latin Block Design was Used in the Study to avoid tissue fatigue. Retraction was done with aluminium chloride; Tetrahydrozoline and Expasyl according to Latin block design. Impressions were poured with die stone. Casts were retrieved and sections were made with die cutter. 3 mm thin slices were obtained. Each slice was used to measure the amount of retraction under stereomicroscope under 20x and images were transferred to image analyser. The amount of gingival retraction obtained by using aluminium chloride as gingival retraction agent was maximum (148238.33 μm(2)) compared to tetrahydrozoline (140737.87 μm(2)) and Expasyl (67784.90 μm(2)).

  6. Microdytes huangyongensis sp. n. and new records of Allopachria Zimmermann, 1924 from Zhejiang Province, China (Coleoptera: Dytiscidae).

    PubMed

    Bian, Dongju; Zhang, Yue; Ji, Lanzhu

    2015-11-12

    An excursion to Zhejiang, China was made in August 2014, and two species of Microdytes J. Balfour-Browne, 1946 (M. uenoi Satô, 1972 and M. huangyongensis sp. n.) and two species of Allopachria Zimmermann, 1924 (A. miaowangi Wewalka, 2010, and A. schoenmanni Wewalka, 2000) were collected. Only one species of Microdytes (M. uenoi Satô, 1972) was recorded from Zhejiang before. The genus Allopachria is reported from Zhejiang for the first time. The genus Microdytes occurs throughout southern and south-eastern Asia. Since the revision of Microdytes by Wewalka (1997), sixteen new species and one new synonymy have been reported (Wewalka 1998; Wewalka & Wang 1998; Wewalka et al. 2007; Bian & Ji 2009; Miller & Wewalka 2010; Wewalka 2011). Including the new species the genus Microdytes comprises 46 species. Specimens were examined with a Leica M205c stereomicroscope. Further details were studied under an Olympus BX51 compound microscope. The photograph of the holotype (Fig 1) was made with a KEYENCE VHX-2000 C digital microscope. All specimens studied were deposited in the Institute of Applied Ecology, Shenyang, Chinese Academy of Sciences (IAECAS).

  7. Effect of air abrasion and polishing on primary molar fissures.

    PubMed

    Lenzi, T L; Menezes, L B R; Soares, F Z M; Rocha, R O

    2013-04-01

    To evaluate the effect of air abrasion and polishing on primary molar fissures under light microscopy. 15 exfoliated primary second molars were longitudinally sectioned and photographed under a stereomicroscope (40×; baseline evaluation). Sections were then randomly allocated into one of the two groups (n = 15) and treated by either air abrasion (aluminium oxide jet) or air polishing (sodium bicarbonate jet) for 30 s. After treatment, sections were washed with an air/water spray, dried with absorbent paper, and photographed as previously described (final evaluation). Baseline and final morphology were compared by two blinded examiners who evaluated changes in the width and depth of fissures. The percentage of changed fissures was analysed, and the two treatments were compared using the Mann-Whitney test (α = 0.01). Both air systems resulted in fissure changes in most (93.3 %) of the sections. No significant differences in fissure width changes were found between treatments, but when changes in fissure depth were evaluated, air polishing was found to be less damaging than air abrasion (p < 0.01). Air abrasion and polishing cause changes to the anatomical configuration of occlusal fissures of primary molars.

  8. Experimental Study of the Impact Damage on AN Al2O3-COATED Glass Under Stress

    NASA Astrophysics Data System (ADS)

    Suh, Chang-Min; Kim, Sung-Ho; Suh, Duck-Young

    The impact damage of an Al2O3-coated soda-lime glass under tensile and compressive stress conditions was investigated by an impact test using a steel ball (2mm dia.). The size of the glass specimens was 40×40×5(mm). In order to change the porosity percent of each specimen, the target distance was set at 120mm and 70mm. Also, the effect of the thickness of the coating layer was shown by two amounts (100 μm and 50 μm). The velocity of the steel balls was set between 30 and 60m/s. After the impact test, the crack patterns and lengths were measured using a stereo-microscope. The tensile and compressive specimens were prepared by inflation and deflation of air pressure within a pressure vessel. It was confirmed that the crack length of the glass under tensile stress was longer than that of glass under compressive stress. Also, the optimum conditions were a target distance of 70mm and 100 μm of a coating thickness, thus resulting in a minimization of porosity percent and area.

  9. Influence of moisture on the apical seal of root canal fillings with five different types of sealer.

    PubMed

    Roggendorf, Matthias Johannes; Ebert, Johannes; Petschelt, Anselm; Frankenberger, Roland

    2007-01-01

    The aim of this study was to evaluate the influence of moisture on apical leakage using five different types of sealer. There were 120 single-rooted teeth instrumented to .02/#60 and randomly assigned to 10 experimental groups, one control group (AH Plus, lateral condensation) (n = 10) or positive/negative controls (n = 5). Before obturation teeth were dried thoroughly, followed by recontamination with moisture in a wet chamber (moist groups; 37 degrees C for 7 days). The teeth of the experimental groups (a, dry; b, moist) were obturated with sealer (groups 1, AH Plus; 2, Apexit; 3, Ketac-Endo; 4, RoekoSeal; 5, Tubli-Seal) and a single gutta-percha cone .02/#55. Teeth were centrifuged (30 x g for 3 minutes) in 5% methylene blue. Linear dye penetration was measured under a stereomicroscope. Moisture led to less microleakage for Apexit, RoekoSeal, and Tubli-Seal and higher values for AH Plus and Ketac-Endo. Multifactorial ANOVA displayed a significant dependence of leakage on sealer (p < 0.001) and the combination sealer or moisture (p < 0.01). It depends on the sealer type in which way moisture affects the apical seal.

  10. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    PubMed Central

    Yang, Xin; Lv, Pin; Liu, Yihong; Si, Wenjie; Feng, Hailan

    2015-01-01

    In this study, the accuracy (precision and trueness) of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1) To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D) comparison. Root mean square (RMS) and color-coded difference images were offered. (2) To assess trueness, micro computed tomography (micro-CT) was used to get the reference model (REF). Deviations between REF and repeated scan models (from (1)) were calculated. (3) To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing. PMID:28793417

  11. A Comparison of Marginal Gaps of All-Ceramic Crowns Constructed from Scanned Impressions and Models.

    PubMed

    Tabesh, Raena; Dudley, James

    This study compared the marginal gaps of computer-aided design/computer-aided manufacture (CAD/CAM)-fabricated all-ceramic crowns constructed from scanned impressions and models and with two different occlusal reduction designs. Two typodont mandibular first molars were prepared to receive CAD/CAM-fabricated all-ceramic crowns. Both molars were prepared to ideal crown reduction, the first with anatomical occlusal reduction (AOR) and the second with completely flat occlusal reduction (FOR). Nine polyvinyl siloxane impressions (PVS) were taken, and nine stone replicas fabricated for each preparation. All impressions and stone models were scanned using a laser scanner (Planmeca Planscan, E4D technologies), and 36 lithium disilicate (IPS e.max CAD) crowns were milled. The marginal gap was measured in four locations using a light stereomicroscope. Crowns constructed from preparations with both occlusal reduction designs demonstrated similar marginal gaps (FOR = 97.98; AOR = 89.12; P = .739). However, all crowns constructed from scanned impressions presented significantly larger marginal gaps than the crowns fabricated from scanned models (impressions = 109.26; models = 77.84; P = .002). Scanning stone models produced all-ceramic crowns with significantly smaller marginal gaps than scanning impressions, irrespective of the occlusal reduction design.

  12. Combined Stereophotogrammetry and Laser-Sintered, Computer-Aided Milling Framework for an Implant-Supported Mandibular Prosthesis: A Case History Report.

    PubMed

    Suarez, Maria J; Paisal, Iria; Rodriguez-Alonso, Veronica; Lopez-Suarez, Carlos

    This study compared the marginal gaps of computer-aided design/computer-aided manufacture (CAD/CAM)-fabricated all-ceramic crowns constructed from scanned impressions and models and with two different occlusal reduction designs. Two typodont mandibular first molars were prepared to receive CAD/CAM-fabricated all-ceramic crowns. Both molars were prepared to ideal crown reduction, the first with anatomical occlusal reduction (AOR) and the second with completely flat occlusal reduction (FOR). Nine polyvinyl siloxane impressions (PVS) were taken, and nine stone replicas fabricated for each preparation. All impressions and stone models were scanned using a laser scanner (Planmeca Planscan, E4D technologies), and 36 lithium disilicate (IPS e.max CAD) crowns were milled. The marginal gap was measured in four locations using a light stereomicroscope. Crowns constructed from preparations with both occlusal reduction designs demonstrated similar marginal gaps (FOR = 97.98; AOR = 89.12; P = .739). However, all crowns constructed from scanned impressions presented significantly larger marginal gaps than the crowns fabricated from scanned models (impressions = 109.26; models = 77.84; P = .002). Scanning stone models produced all-ceramic crowns with significantly smaller marginal gaps than scanning impressions, irrespective of the occlusal reduction design.

  13. Comparative anatomy of the ciliary body of the West Indian manatee (Trichechus manatus) and selected species.

    PubMed

    Natiello, Michelle; Lewis, Patricia; Samuelson, Don

    2005-01-01

    To examine the anatomy of the ciliary body in the West Indian manatee (Trichechus manatus), paying close attention to its vascularization and to compare to those of its distant relative, the African elephant (Loxodonta africana), the amphibious hippopotamus (Hippopotamus amphibius) and the aquatic short-finned pilot whale (Globicephala macrorhynchus). Specimens from each species were preserved in 10% buffered formalin, and observed stereomicroscopically before being embedded in paraffin, sectioned and stained by Masson trichrome, hematoxylin and eosin, and periodic acid-Schiff for light microscopic evaluation. The network of blood vessels in the ciliary processes of the West Indian manatee appear to have an intricate pattern, especially with regard to venous outflow. Those of the elephant are slightly less complex, while those of the hippopotamus and whale have different vascular patterns within the ciliary body. Musculature within the ciliary body is absent within the manatee and pilot whale. In general, there appears to be a direct relationship between the increased development of vasculature and the loss of musculature within the ciliary bodies of the aquatic and amphibious mammals presently studied. Specifically, the ciliary body of the West Indian manatee has a comparatively unique construction, especially with regard to its vasculature.

  14. Evaluation of adding item-response theory analysis for evaluation of the European Board of Ophthalmology Diploma examination.

    PubMed

    Mathysen, Danny G P; Aclimandos, Wagih; Roelant, Ella; Wouters, Kristien; Creuzot-Garcher, Catherine; Ringens, Peter J; Hawlina, Marko; Tassignon, Marie-José

    2013-11-01

    To investigate whether introduction of item-response theory (IRT) analysis, in parallel to the 'traditional' statistical analysis methods available for performance evaluation of multiple T/F items as used in the European Board of Ophthalmology Diploma (EBOD) examination, has proved beneficial, and secondly, to study whether the overall assessment performance of the current written part of EBOD is sufficiently high (KR-20≥ 0.90) to be kept as examination format in future EBOD editions. 'Traditional' analysis methods for individual MCQ item performance comprise P-statistics, Rit-statistics and item discrimination, while overall reliability is evaluated through KR-20 for multiple T/F items. The additional set of statistical analysis methods for the evaluation of EBOD comprises mainly IRT analysis. These analysis techniques are used to monitor whether the introduction of negative marking for incorrect answers (since EBOD 2010) has a positive influence on the statistical performance of EBOD as a whole and its individual test items in particular. Item-response theory analysis demonstrated that item performance parameters should not be evaluated individually, but should be related to one another. Before the introduction of negative marking, the overall EBOD reliability (KR-20) was good though with room for improvement (EBOD 2008: 0.81; EBOD 2009: 0.78). After the introduction of negative marking, the overall reliability of EBOD improved significantly (EBOD 2010: 0.92; EBOD 2011:0.91; EBOD 2012: 0.91). Although many statistical performance parameters are available to evaluate individual items, our study demonstrates that the overall reliability assessment remains the only crucial parameter to be evaluated allowing comparison. While individual item performance analysis is worthwhile to undertake as secondary analysis, drawing final conclusions seems to be more difficult. Performance parameters need to be related, as shown by IRT analysis. Therefore, IRT analysis has proved beneficial for the statistical analysis of EBOD. Introduction of negative marking has led to a significant increase in the reliability (KR-20 > 0.90), indicating that the current examination format can be kept for future EBOD examinations. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. Two Paradoxes in Linear Regression Analysis.

    PubMed

    Feng, Ge; Peng, Jing; Tu, Dongke; Zheng, Julia Z; Feng, Changyong

    2016-12-25

    Regression is one of the favorite tools in applied statistics. However, misuse and misinterpretation of results from regression analysis are common in biomedical research. In this paper we use statistical theory and simulation studies to clarify some paradoxes around this popular statistical method. In particular, we show that a widely used model selection procedure employed in many publications in top medical journals is wrong. Formal procedures based on solid statistical theory should be used in model selection.

  16. Bayesian Statistics and Uncertainty Quantification for Safety Boundary Analysis in Complex Systems

    NASA Technical Reports Server (NTRS)

    He, Yuning; Davies, Misty Dawn

    2014-01-01

    The analysis of a safety-critical system often requires detailed knowledge of safe regions and their highdimensional non-linear boundaries. We present a statistical approach to iteratively detect and characterize the boundaries, which are provided as parameterized shape candidates. Using methods from uncertainty quantification and active learning, we incrementally construct a statistical model from only few simulation runs and obtain statistically sound estimates of the shape parameters for safety boundaries.

  17. A Study on Predictive Analytics Application to Ship Machinery Maintenance

    DTIC Science & Technology

    2013-09-01

    Looking at the nature of the time series forecasting method , it would be better applied to offline analysis . The application for real- time online...other system attributes in future. Two techniques of statistical analysis , mainly time series models and cumulative sum control charts, are discussed in...statistical tool employed for the two techniques of statistical analysis . Both time series forecasting as well as CUSUM control charts are shown to be

  18. Vibratory Response and Acoustical Radiation of a Water-Loaded, Turbulence-Excited Plate-Cavity System--Option 6

    DTIC Science & Technology

    1975-07-01

    Statistical Energy Analysis MAJOR ASSUMPTIONS AND LIMITATIONS . Simply supported panel it contidarad to ba vibrating freely in a mode consisting of e...Shells: Statistical Energy Analysis . Modal Coupling and Nonresonant Transmission. Univ Houston, Dept Mech Eng Tech Report 21 (Aug 1970); also J...Oscillators. J. Acoust. Soc. Am., Vol. 34, No. 5 (May 1962). 14. Ungar, E.E., Fundamentals of Statistical Energy Analysis of Vibrating Systems, Tech

  19. A Mechanical Power Flow Capability for the Finite Element Code NASTRAN

    DTIC Science & Technology

    1989-07-01

    perimental methods. statistical energy analysis , the finite element method, and a finite element analog-,y using heat conduction equations. Experimental...weights and inertias of the transducers attached to an experimental structure may produce accuracy problems. Statistical energy analysis (SEA) is a...405-422 (1987). 8. Lyon, R.L., Statistical Energy Analysis of Dynamical Sistems, The M.I.T. Press, (1975). 9. Mickol, J.D., and R.J. Bernhard, "An

  20. The Shock and Vibration Digest. Volume 13, Number 12

    DTIC Science & Technology

    1981-12-01

    Resulting Unsteady Forces and Flow Phenomenon. Part III 26 BOOK REVIEWS STATISTICAL ENERGY ANALYSIS Chapter IV considers the problems of estimating J OF...stress, acceleration, modes. Statistical energy analysis (SEA), which is and pressure; estimations of the average system expressed in terms of random...by F.C. Nelson, SVD, 13 (8), pp 30-31 (Aug 1981) Lyons, R.H., Statistical Energy Analysis of Dynamic Systems, MIT Press, Cambridge, MA; Revieed by H

  1. NAUSEA and the Principle of Supplementarity of Damping and Isolation in Noise Control.

    DTIC Science & Technology

    1980-02-01

    New approaches and uses of the statistical energy analysis (NAUSEA) have been considered and developed in recent months. The advances were made...possible in that the requirement, in the olde statistical energy analysis , that the dynamic systems be highly reverberant and the couplings between the...analytical consideration in terms of the statistical energy analysis (SEA). A brief discussion and simple examples that relate to these recent advances

  2. Analysis and meta-analysis of single-case designs with a standardized mean difference statistic: a primer and applications.

    PubMed

    Shadish, William R; Hedges, Larry V; Pustejovsky, James E

    2014-04-01

    This article presents a d-statistic for single-case designs that is in the same metric as the d-statistic used in between-subjects designs such as randomized experiments and offers some reasons why such a statistic would be useful in SCD research. The d has a formal statistical development, is accompanied by appropriate power analyses, and can be estimated using user-friendly SPSS macros. We discuss both advantages and disadvantages of d compared to other approaches such as previous d-statistics, overlap statistics, and multilevel modeling. It requires at least three cases for computation and assumes normally distributed outcomes and stationarity, assumptions that are discussed in some detail. We also show how to test these assumptions. The core of the article then demonstrates in depth how to compute d for one study, including estimation of the autocorrelation and the ratio of between case variance to total variance (between case plus within case variance), how to compute power using a macro, and how to use the d to conduct a meta-analysis of studies using single-case designs in the free program R, including syntax in an appendix. This syntax includes how to read data, compute fixed and random effect average effect sizes, prepare a forest plot and a cumulative meta-analysis, estimate various influence statistics to identify studies contributing to heterogeneity and effect size, and do various kinds of publication bias analyses. This d may prove useful for both the analysis and meta-analysis of data from SCDs. Copyright © 2013 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  3. Measuring the statistical validity of summary meta-analysis and meta-regression results for use in clinical practice.

    PubMed

    Willis, Brian H; Riley, Richard D

    2017-09-20

    An important question for clinicians appraising a meta-analysis is: are the findings likely to be valid in their own practice-does the reported effect accurately represent the effect that would occur in their own clinical population? To this end we advance the concept of statistical validity-where the parameter being estimated equals the corresponding parameter for a new independent study. Using a simple ('leave-one-out') cross-validation technique, we demonstrate how we may test meta-analysis estimates for statistical validity using a new validation statistic, Vn, and derive its distribution. We compare this with the usual approach of investigating heterogeneity in meta-analyses and demonstrate the link between statistical validity and homogeneity. Using a simulation study, the properties of Vn and the Q statistic are compared for univariate random effects meta-analysis and a tailored meta-regression model, where information from the setting (included as model covariates) is used to calibrate the summary estimate to the setting of application. Their properties are found to be similar when there are 50 studies or more, but for fewer studies Vn has greater power but a higher type 1 error rate than Q. The power and type 1 error rate of Vn are also shown to depend on the within-study variance, between-study variance, study sample size, and the number of studies in the meta-analysis. Finally, we apply Vn to two published meta-analyses and conclude that it usefully augments standard methods when deciding upon the likely validity of summary meta-analysis estimates in clinical practice. © 2017 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. © 2017 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.

  4. Survey of editors and reviewers of high-impact psychology journals: statistical and research design problems in submitted manuscripts.

    PubMed

    Harris, Alex; Reeder, Rachelle; Hyun, Jenny

    2011-01-01

    The authors surveyed 21 editors and reviewers from major psychology journals to identify and describe the statistical and design errors they encounter most often and to get their advice regarding prevention of these problems. Content analysis of the text responses revealed themes in 3 major areas: (a) problems with research design and reporting (e.g., lack of an a priori power analysis, lack of congruence between research questions and study design/analysis, failure to adequately describe statistical procedures); (b) inappropriate data analysis (e.g., improper use of analysis of variance, too many statistical tests without adjustments, inadequate strategy for addressing missing data); and (c) misinterpretation of results. If researchers attended to these common methodological and analytic issues, the scientific quality of manuscripts submitted to high-impact psychology journals might be significantly improved.

  5. [Comparison of application of Cochran-Armitage trend test and linear regression analysis for rate trend analysis in epidemiology study].

    PubMed

    Wang, D Z; Wang, C; Shen, C F; Zhang, Y; Zhang, H; Song, G D; Xue, X D; Xu, Z L; Zhang, S; Jiang, G H

    2017-05-10

    We described the time trend of acute myocardial infarction (AMI) from 1999 to 2013 in Tianjin incidence rate with Cochran-Armitage trend (CAT) test and linear regression analysis, and the results were compared. Based on actual population, CAT test had much stronger statistical power than linear regression analysis for both overall incidence trend and age specific incidence trend (Cochran-Armitage trend P value

  6. Integration of Research Studies: Meta-Analysis of Research. Methods of Integrative Analysis; Final Report.

    ERIC Educational Resources Information Center

    Glass, Gene V.; And Others

    Integrative analysis, or what is coming to be known as meta-analysis, is the integration of the findings of many empirical research studies of a topic. Meta-analysis differs from traditional narrative forms of research reviewing in that it is more quantitative and statistical. Thus, the methods of meta-analysis are merely statistical methods,…

  7. Statistical Learning in Specific Language Impairment: A Meta-Analysis

    ERIC Educational Resources Information Center

    Lammertink, Imme; Boersma, Paul; Wijnen, Frank; Rispens, Judith

    2017-01-01

    Purpose: The current meta-analysis provides a quantitative overview of published and unpublished studies on statistical learning in the auditory verbal domain in people with and without specific language impairment (SLI). The database used for the meta-analysis is accessible online and open to updates (Community-Augmented Meta-Analysis), which…

  8. Propensity Score Analysis: An Alternative Statistical Approach for HRD Researchers

    ERIC Educational Resources Information Center

    Keiffer, Greggory L.; Lane, Forrest C.

    2016-01-01

    Purpose: This paper aims to introduce matching in propensity score analysis (PSA) as an alternative statistical approach for researchers looking to make causal inferences using intact groups. Design/methodology/approach: An illustrative example demonstrated the varying results of analysis of variance, analysis of covariance and PSA on a heuristic…

  9. A critique of the usefulness of inferential statistics in applied behavior analysis

    PubMed Central

    Hopkins, B. L.; Cole, Brian L.; Mason, Tina L.

    1998-01-01

    Researchers continue to recommend that applied behavior analysts use inferential statistics in making decisions about effects of independent variables on dependent variables. In many other approaches to behavioral science, inferential statistics are the primary means for deciding the importance of effects. Several possible uses of inferential statistics are considered. Rather than being an objective means for making decisions about effects, as is often claimed, inferential statistics are shown to be subjective. It is argued that the use of inferential statistics adds nothing to the complex and admittedly subjective nonstatistical methods that are often employed in applied behavior analysis. Attacks on inferential statistics that are being made, perhaps with increasing frequency, by those who are not behavior analysts, are discussed. These attackers are calling for banning the use of inferential statistics in research publications and commonly recommend that behavioral scientists should switch to using statistics aimed at interval estimation or the method of confidence intervals. Interval estimation is shown to be contrary to the fundamental assumption of behavior analysis that only individuals behave. It is recommended that authors who wish to publish the results of inferential statistics be asked to justify them as a means for helping us to identify any ways in which they may be useful. PMID:22478304

  10. Statistical Analysis Techniques for Small Sample Sizes

    NASA Technical Reports Server (NTRS)

    Navard, S. E.

    1984-01-01

    The small sample sizes problem which is encountered when dealing with analysis of space-flight data is examined. Because of such a amount of data available, careful analyses are essential to extract the maximum amount of information with acceptable accuracy. Statistical analysis of small samples is described. The background material necessary for understanding statistical hypothesis testing is outlined and the various tests which can be done on small samples are explained. Emphasis is on the underlying assumptions of each test and on considerations needed to choose the most appropriate test for a given type of analysis.

  11. Statistical analysis of 59 inspected SSME HPFTP turbine blades (uncracked and cracked)

    NASA Technical Reports Server (NTRS)

    Wheeler, John T.

    1987-01-01

    The numerical results of statistical analysis of the test data of Space Shuttle Main Engine high pressure fuel turbopump second-stage turbine blades, including some with cracks are presented. Several statistical methods use the test data to determine the application of differences in frequency variations between the uncracked and cracked blades.

  12. Sociological Paradoxes and Graduate Statistics Classes. A Response to "The Sociology of Teaching Graduate Statistics"

    ERIC Educational Resources Information Center

    Hardy, Melissa

    2005-01-01

    This article presents a response to Timothy Patrick Moran's article "The Sociology of Teaching Graduate Statistics." In his essay, Moran argues that exciting developments in techniques of quantitative analysis are currently coupled with a much less exciting formulaic approach to teaching sociology graduate students about quantitative analysis. The…

  13. A new statistic for the analysis of circular data in gamma-ray astronomy

    NASA Technical Reports Server (NTRS)

    Protheroe, R. J.

    1985-01-01

    A new statistic is proposed for the analysis of circular data. The statistic is designed specifically for situations where a test of uniformity is required which is powerful against alternatives in which a small fraction of the observations is grouped in a small range of directions, or phases.

  14. The Importance of Statistical Modeling in Data Analysis and Inference

    ERIC Educational Resources Information Center

    Rollins, Derrick, Sr.

    2017-01-01

    Statistical inference simply means to draw a conclusion based on information that comes from data. Error bars are the most commonly used tool for data analysis and inference in chemical engineering data studies. This work demonstrates, using common types of data collection studies, the importance of specifying the statistical model for sound…

  15. Explorations in Statistics: The Analysis of Ratios and Normalized Data

    ERIC Educational Resources Information Center

    Curran-Everett, Douglas

    2013-01-01

    Learning about statistics is a lot like learning about science: the learning is more meaningful if you can actively explore. This ninth installment of "Explorations in Statistics" explores the analysis of ratios and normalized--or standardized--data. As researchers, we compute a ratio--a numerator divided by a denominator--to compute a…

  16. Efficiency Analysis: Enhancing the Statistical and Evaluative Power of the Regression-Discontinuity Design.

    ERIC Educational Resources Information Center

    Madhere, Serge

    An analytic procedure, efficiency analysis, is proposed for improving the utility of quantitative program evaluation for decision making. The three features of the procedure are explained: (1) for statistical control, it adopts and extends the regression-discontinuity design; (2) for statistical inferences, it de-emphasizes hypothesis testing in…

  17. A Realistic Experimental Design and Statistical Analysis Project

    ERIC Educational Resources Information Center

    Muske, Kenneth R.; Myers, John A.

    2007-01-01

    A realistic applied chemical engineering experimental design and statistical analysis project is documented in this article. This project has been implemented as part of the professional development and applied statistics courses at Villanova University over the past five years. The novel aspects of this project are that the students are given a…

  18. Item Analysis Appropriate for Domain-Referenced Classroom Testing. (Project Technical Report Number 1).

    ERIC Educational Resources Information Center

    Nitko, Anthony J.; Hsu, Tse-chi

    Item analysis procedures appropriate for domain-referenced classroom testing are described. A conceptual framework within which item statistics can be considered and promising statistics in light of this framework are presented. The sampling fluctuations of the more promising item statistics for sample sizes comparable to the typical classroom…

  19. Internet Data Analysis for the Undergraduate Statistics Curriculum

    ERIC Educational Resources Information Center

    Sanchez, Juana; He, Yan

    2005-01-01

    Statistics textbooks for undergraduates have not caught up with the enormous amount of analysis of Internet data that is taking place these days. Case studies that use Web server log data or Internet network traffic data are rare in undergraduate Statistics education. And yet these data provide numerous examples of skewed and bimodal…

  20. The Heuristics of Statistical Argumentation: Scaffolding at the Postsecondary Level

    ERIC Educational Resources Information Center

    Pardue, Teneal Messer

    2017-01-01

    Language plays a key role in statistics and, by extension, in statistics education. Enculturating students into the practice of statistics requires preparing them to communicate results of data analysis. Statistical argumentation is one way of providing structure to facilitate discourse in the statistics classroom. In this study, a teaching…

  1. Research design and statistical methods in Pakistan Journal of Medical Sciences (PJMS)

    PubMed Central

    Akhtar, Sohail; Shah, Syed Wadood Ali; Rafiq, M.; Khan, Ajmal

    2016-01-01

    Objective: This article compares the study design and statistical methods used in 2005, 2010 and 2015 of Pakistan Journal of Medical Sciences (PJMS). Methods: Only original articles of PJMS were considered for the analysis. The articles were carefully reviewed for statistical methods and designs, and then recorded accordingly. The frequency of each statistical method and research design was estimated and compared with previous years. Results: A total of 429 articles were evaluated (n=74 in 2005, n=179 in 2010, n=176 in 2015) in which 171 (40%) were cross-sectional and 116 (27%) were prospective study designs. A verity of statistical methods were found in the analysis. The most frequent methods include: descriptive statistics (n=315, 73.4%), chi-square/Fisher’s exact tests (n=205, 47.8%) and student t-test (n=186, 43.4%). There was a significant increase in the use of statistical methods over time period: t-test, chi-square/Fisher’s exact test, logistic regression, epidemiological statistics, and non-parametric tests. Conclusion: This study shows that a diverse variety of statistical methods have been used in the research articles of PJMS and frequency improved from 2005 to 2015. However, descriptive statistics was the most frequent method of statistical analysis in the published articles while cross-sectional study design was common study design. PMID:27022365

  2. Statistical analysis of the national crash severity study data

    DOT National Transportation Integrated Search

    1980-08-01

    This is the Final Report on a two-year statistical analysis of the data collected in the National Crash Severity Study (NCSS). The analysis presented is primarily concerned with the relationship between occupant injury severity and the crash conditio...

  3. 3013 DE INNER CONTAINER CLOSURE WELD CORROSION EVALUATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mickalonis, J.

    Destructive evaluation (DE) of 3013 containers is one part of the U. S. Department of Energy Integrated Surveillance Program. During standard DE of 3013 containers, visual examinations for pitting and stress corrosion cracking (SCC) are performed on the accessible surfaces of the outer, inner, and convenience containers, which make up the 3013 container. As a result of 3013 DE additional analysis, the area near the inner container closure weld has been identified as being a region of increased corrosion susceptibility, which may provide a pathway for corrosive gases to the outer container. This area has a higher residual stress, anmore » altered microstructure, and less corrosion resistant weld oxides as a result of the welding process as well as a lower temperature than other areas of the container, which may increase the absorption of moisture on the surface. The deposition of moisture in this stressed region could lead to pitting and stress corrosion cracking. During FY2013, the inner container closure weld area was more closely evaluated on several archived samples from DE containers. These containers included FY09 DE2, FY12 DE4, FY12 DE6 and FY12 DE7 and the Hanford High Moisture Container. The additional examinations included visual observations with a stereomicroscope, scanning electron microscopy along with energy dispersive spectroscopy for chemical analysis, and serial metallography of the sidewall and lid that are part of the inner container closure weld region. Pitting was observed in all the samples taken from the closure weld regions of the examined inner containers. This pitting was generally less 20 μm with most less than 5m. These pits were similar in depth to those observed in the vapor exposed surfaces of teardrops in the shelf life corrosion testing. Cracking was not observed on either the vapor-exposed surfaces of the teardrop coupons or the inner container closure weld region. Further testing is necessary to determine if the conditions in the welded inner container could support SCC during the 50 year life time for the 3013 container.« less

  4. Applications of statistics to medical science (1) Fundamental concepts.

    PubMed

    Watanabe, Hiroshi

    2011-01-01

    The conceptual framework of statistical tests and statistical inferences are discussed, and the epidemiological background of statistics is briefly reviewed. This study is one of a series in which we survey the basics of statistics and practical methods used in medical statistics. Arguments related to actual statistical analysis procedures will be made in subsequent papers.

  5. A quadratically regularized functional canonical correlation analysis for identifying the global structure of pleiotropy with NGS data

    PubMed Central

    Zhu, Yun; Fan, Ruzong; Xiong, Momiao

    2017-01-01

    Investigating the pleiotropic effects of genetic variants can increase statistical power, provide important information to achieve deep understanding of the complex genetic structures of disease, and offer powerful tools for designing effective treatments with fewer side effects. However, the current multiple phenotype association analysis paradigm lacks breadth (number of phenotypes and genetic variants jointly analyzed at the same time) and depth (hierarchical structure of phenotype and genotypes). A key issue for high dimensional pleiotropic analysis is to effectively extract informative internal representation and features from high dimensional genotype and phenotype data. To explore correlation information of genetic variants, effectively reduce data dimensions, and overcome critical barriers in advancing the development of novel statistical methods and computational algorithms for genetic pleiotropic analysis, we proposed a new statistic method referred to as a quadratically regularized functional CCA (QRFCCA) for association analysis which combines three approaches: (1) quadratically regularized matrix factorization, (2) functional data analysis and (3) canonical correlation analysis (CCA). Large-scale simulations show that the QRFCCA has a much higher power than that of the ten competing statistics while retaining the appropriate type 1 errors. To further evaluate performance, the QRFCCA and ten other statistics are applied to the whole genome sequencing dataset from the TwinsUK study. We identify a total of 79 genes with rare variants and 67 genes with common variants significantly associated with the 46 traits using QRFCCA. The results show that the QRFCCA substantially outperforms the ten other statistics. PMID:29040274

  6. How to interpret the results of medical time series data analysis: Classical statistical approaches versus dynamic Bayesian network modeling.

    PubMed

    Onisko, Agnieszka; Druzdzel, Marek J; Austin, R Marshall

    2016-01-01

    Classical statistics is a well-established approach in the analysis of medical data. While the medical community seems to be familiar with the concept of a statistical analysis and its interpretation, the Bayesian approach, argued by many of its proponents to be superior to the classical frequentist approach, is still not well-recognized in the analysis of medical data. The goal of this study is to encourage data analysts to use the Bayesian approach, such as modeling with graphical probabilistic networks, as an insightful alternative to classical statistical analysis of medical data. This paper offers a comparison of two approaches to analysis of medical time series data: (1) classical statistical approach, such as the Kaplan-Meier estimator and the Cox proportional hazards regression model, and (2) dynamic Bayesian network modeling. Our comparison is based on time series cervical cancer screening data collected at Magee-Womens Hospital, University of Pittsburgh Medical Center over 10 years. The main outcomes of our comparison are cervical cancer risk assessments produced by the three approaches. However, our analysis discusses also several aspects of the comparison, such as modeling assumptions, model building, dealing with incomplete data, individualized risk assessment, results interpretation, and model validation. Our study shows that the Bayesian approach is (1) much more flexible in terms of modeling effort, and (2) it offers an individualized risk assessment, which is more cumbersome for classical statistical approaches.

  7. Two Paradoxes in Linear Regression Analysis

    PubMed Central

    FENG, Ge; PENG, Jing; TU, Dongke; ZHENG, Julia Z.; FENG, Changyong

    2016-01-01

    Summary Regression is one of the favorite tools in applied statistics. However, misuse and misinterpretation of results from regression analysis are common in biomedical research. In this paper we use statistical theory and simulation studies to clarify some paradoxes around this popular statistical method. In particular, we show that a widely used model selection procedure employed in many publications in top medical journals is wrong. Formal procedures based on solid statistical theory should be used in model selection. PMID:28638214

  8. Analysis Code - Data Analysis in 'Leveraging Multiple Statistical Methods for Inverse Prediction in Nuclear Forensics Applications' (LMSMIPNFA) v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, John R

    R code that performs the analysis of a data set presented in the paper ‘Leveraging Multiple Statistical Methods for Inverse Prediction in Nuclear Forensics Applications’ by Lewis, J., Zhang, A., Anderson-Cook, C. It provides functions for doing inverse predictions in this setting using several different statistical methods. The data set is a publicly available data set from a historical Plutonium production experiment.

  9. Performance Analysis of Live-Virtual-Constructive and Distributed Virtual Simulations: Defining Requirements in Terms of Temporal Consistency

    DTIC Science & Technology

    2009-12-01

    events. Work associated with aperiodic tasks have the same statistical behavior and the same timing requirements. The timing deadlines are soft. • Sporadic...answers, but it is possible to calculate how precise the estimates are. Simulation-based performance analysis of a model includes a statistical ...to evaluate all pos- sible states in a timely manner. This is the principle reason for resorting to simulation and statistical analysis to evaluate

  10. The Shock and Vibration Digest. Volume 15, Number 7

    DTIC Science & Technology

    1983-07-01

    systems noise -- for tant analytical tool, the statistical energy analysis example, from a specific metal, chain driven, con- method, has been the subject...34Experimental Determination of Vibration Parameters Re- ~~~quired in the Statistical Energy Analysis Meth- .,i. 31. Dubowsky, S. and Morris, T.L., "An...34Coupling Loss Factors for 55. Upton, R., "Sound Intensity -. A Powerful New Statistical Energy Analysis of Sound Trans- Measurement Tool," S/V, Sound

  11. An Analysis of Effects of Variable Factors on Weapon Performance

    DTIC Science & Technology

    1993-03-01

    ALTERNATIVE ANALYSIS A. CATEGORICAL DATA ANALYSIS Statistical methodology for categorical data analysis traces its roots to the work of Francis Galton in the...choice of statistical tests . This thesis examines an analysis performed by Surface Warfare Development Group (SWDG). The SWDG analysis is shown to be...incorrect due to the misapplication of testing methods. A corrected analysis is presented and recommendations suggested for changes to the testing

  12. OASIS 2: online application for survival analysis 2 with features for the analysis of maximal lifespan and healthspan in aging research.

    PubMed

    Han, Seong Kyu; Lee, Dongyeop; Lee, Heetak; Kim, Donghyo; Son, Heehwa G; Yang, Jae-Seong; Lee, Seung-Jae V; Kim, Sanguk

    2016-08-30

    Online application for survival analysis (OASIS) has served as a popular and convenient platform for the statistical analysis of various survival data, particularly in the field of aging research. With the recent advances in the fields of aging research that deal with complex survival data, we noticed a need for updates to the current version of OASIS. Here, we report OASIS 2 (http://sbi.postech.ac.kr/oasis2), which provides extended statistical tools for survival data and an enhanced user interface. In particular, OASIS 2 enables the statistical comparison of maximal lifespans, which is potentially useful for determining key factors that limit the lifespan of a population. Furthermore, OASIS 2 provides statistical and graphical tools that compare values in different conditions and times. That feature is useful for comparing age-associated changes in physiological activities, which can be used as indicators of "healthspan." We believe that OASIS 2 will serve as a standard platform for survival analysis with advanced and user-friendly statistical tools for experimental biologists in the field of aging research.

  13. Analysis of Coastal Dunes: A Remote Sensing and Statistical Approach.

    ERIC Educational Resources Information Center

    Jones, J. Richard

    1985-01-01

    Remote sensing analysis and statistical methods were used to analyze the coastal dunes of Plum Island, Massachusetts. The research methodology used provides an example of a student project for remote sensing, geomorphology, or spatial analysis courses at the university level. (RM)

  14. Reporting quality of statistical methods in surgical observational studies: protocol for systematic review.

    PubMed

    Wu, Robert; Glen, Peter; Ramsay, Tim; Martel, Guillaume

    2014-06-28

    Observational studies dominate the surgical literature. Statistical adjustment is an important strategy to account for confounders in observational studies. Research has shown that published articles are often poor in statistical quality, which may jeopardize their conclusions. The Statistical Analyses and Methods in the Published Literature (SAMPL) guidelines have been published to help establish standards for statistical reporting.This study will seek to determine whether the quality of statistical adjustment and the reporting of these methods are adequate in surgical observational studies. We hypothesize that incomplete reporting will be found in all surgical observational studies, and that the quality and reporting of these methods will be of lower quality in surgical journals when compared with medical journals. Finally, this work will seek to identify predictors of high-quality reporting. This work will examine the top five general surgical and medical journals, based on a 5-year impact factor (2007-2012). All observational studies investigating an intervention related to an essential component area of general surgery (defined by the American Board of Surgery), with an exposure, outcome, and comparator, will be included in this systematic review. Essential elements related to statistical reporting and quality were extracted from the SAMPL guidelines and include domains such as intent of analysis, primary analysis, multiple comparisons, numbers and descriptive statistics, association and correlation analyses, linear regression, logistic regression, Cox proportional hazard analysis, analysis of variance, survival analysis, propensity analysis, and independent and correlated analyses. Each article will be scored as a proportion based on fulfilling criteria in relevant analyses used in the study. A logistic regression model will be built to identify variables associated with high-quality reporting. A comparison will be made between the scores of surgical observational studies published in medical versus surgical journals. Secondary outcomes will pertain to individual domains of analysis. Sensitivity analyses will be conducted. This study will explore the reporting and quality of statistical analyses in surgical observational studies published in the most referenced surgical and medical journals in 2013 and examine whether variables (including the type of journal) can predict high-quality reporting.

  15. Statistical parsimony networks and species assemblages in Cephalotrichid nemerteans (nemertea).

    PubMed

    Chen, Haixia; Strand, Malin; Norenburg, Jon L; Sun, Shichun; Kajihara, Hiroshi; Chernyshev, Alexey V; Maslakova, Svetlana A; Sundberg, Per

    2010-09-21

    It has been suggested that statistical parsimony network analysis could be used to get an indication of species represented in a set of nucleotide data, and the approach has been used to discuss species boundaries in some taxa. Based on 635 base pairs of the mitochondrial protein-coding gene cytochrome c oxidase I (COI), we analyzed 152 nemertean specimens using statistical parsimony network analysis with the connection probability set to 95%. The analysis revealed 15 distinct networks together with seven singletons. Statistical parsimony yielded three networks supporting the species status of Cephalothrix rufifrons, C. major and C. spiralis as they currently have been delineated by morphological characters and geographical location. Many other networks contained haplotypes from nearby geographical locations. Cladistic structure by maximum likelihood analysis overall supported the network analysis, but indicated a false positive result where subnetworks should have been connected into one network/species. This probably is caused by undersampling of the intraspecific haplotype diversity. Statistical parsimony network analysis provides a rapid and useful tool for detecting possible undescribed/cryptic species among cephalotrichid nemerteans based on COI gene. It should be combined with phylogenetic analysis to get indications of false positive results, i.e., subnetworks that would have been connected with more extensive haplotype sampling.

  16. Statistical analysis of arthroplasty data

    PubMed Central

    2011-01-01

    It is envisaged that guidelines for statistical analysis and presentation of results will improve the quality and value of research. The Nordic Arthroplasty Register Association (NARA) has therefore developed guidelines for the statistical analysis of arthroplasty register data. The guidelines are divided into two parts, one with an introduction and a discussion of the background to the guidelines (Ranstam et al. 2011a, see pages x-y in this issue), and this one with a more technical statistical discussion on how specific problems can be handled. This second part contains (1) recommendations for the interpretation of methods used to calculate survival, (2) recommendations on howto deal with bilateral observations, and (3) a discussion of problems and pitfalls associated with analysis of factors that influence survival or comparisons between outcomes extracted from different hospitals. PMID:21619500

  17. An Analysis of Research Methods and Statistical Techniques Used by Doctoral Dissertation at the Education Sciences in Turkey

    ERIC Educational Resources Information Center

    Karadag, Engin

    2010-01-01

    To assess research methods and analysis of statistical techniques employed by educational researchers, this study surveyed unpublished doctoral dissertation from 2003 to 2007. Frequently used research methods consisted of experimental research; a survey; a correlational study; and a case study. Descriptive statistics, t-test, ANOVA, factor…

  18. Analysis of thrips distribution: application of spatial statistics and Kriging

    Treesearch

    John Aleong; Bruce L. Parker; Margaret Skinner; Diantha Howard

    1991-01-01

    Kriging is a statistical technique that provides predictions for spatially and temporally correlated data. Observations of thrips distribution and density in Vermont soils are made in both space and time. Traditional statistical analysis of such data assumes that the counts taken over space and time are independent, which is not necessarily true. Therefore, to analyze...

  19. Risk Factors for Sexual Violence in the Military: An Analysis of Sexual Assault and Sexual Harassment Incidents and Reporting

    DTIC Science & Technology

    2017-03-01

    53 ix LIST OF TABLES Table 1. Descriptive Statistics for Control Variables by... Statistics for Control Variables by Gender (Random Subsample with Complete Survey) ............................................................30 Table...empirical analysis. Chapter IV describes the summary statistics and results. Finally, Chapter V offers concluding thoughts, study limitations, and

  20. A First Assignment to Create Student Buy-In in an Introductory Business Statistics Course

    ERIC Educational Resources Information Center

    Newfeld, Daria

    2016-01-01

    This paper presents a sample assignment to be administered after the first two weeks of an introductory business focused statistics course in order to promote student buy-in. This assignment integrates graphical displays of data, descriptive statistics and cross-tabulation analysis through the lens of a marketing analysis study. A marketing sample…

Top