Science.gov

Sample records for sterile cross-clade protection

  1. Feasibility of reconstructed ancestral H5N1 influenza viruses for cross-clade protective vaccine development

    PubMed Central

    Ducatez, Mariette F.; Bahl, Justin; Griffin, Yolanda; Stigger-Rosser, Evelyn; Franks, John; Barman, Subrata; Vijaykrishna, Dhanasekaran; Webb, Ashley; Guan, Yi; Webster, Robert G.; Smith, Gavin J. D.; Webby, Richard J.

    2011-01-01

    Since the reemergence of highly pathogenic H5N1 influenza viruses in humans in 2003, these viruses have spread throughout avian species in Asia, Europe, and Africa. Their sustained circulation has resulted in the evolution of phylogenetically diverse lineages. Viruses from these lineages show considerable antigenic variation, which has confounded vaccine planning efforts. We reconstructed ancestral protein sequences at several nodes of the hemagglutinin (HA) and neuraminidase (NA) gene phylogenies that represent ancestors to diverse H5N1 virus clades. By using the same methods that have been used to generate currently licensed inactivated H5N1 vaccines, we were able to produce a panel of replication competent influenza viruses containing synthesized HA and NA genes representing the reconstructed ancestral proteins. We identified two of these viruses that showed promising in vitro cross-reactivity with clade 1, 2.1, 2.2, 2.3.4, and 4 viruses. To confirm that vaccine antigens derived from these viruses were able to elicit functional antibodies following immunization, we created whole-virus vaccines and compared their protective efficacy versus that of antigens from positive control, naturally occurring, and broadly reactive H5N1 viruses. The ancestral viruses’ vaccines provided robust protection against morbidity and mortality in ferrets challenged with H5N1 strains from clades 1, 2.1, and 2.2 in a manner similar to those based on the control strains. These findings provide proof of principle that viable, computationally derived vaccine seed viruses can be constructed within the context of currently licensed vaccine platforms. Such technologies should be explored to enhance the cross reactivity and availability of H5N1 influenza vaccines. PMID:21173241

  2. Cross-clade protective immune responses of NS1-truncated live attenuated H5N1 avian influenza vaccines.

    PubMed

    Shi, Shaohua; Chen, Sujuan; Han, Weizhou; Wu, Bai; Zhang, Xiaojian; Tang, Ying; Wang, Xiao; Zhu, Yinbiao; Peng, Daxin; Liu, Xiufan

    2016-01-12

    H5N1 highly pathogenic avian influenza (HPAI) has raised global concern for causing huge economic losses in poultry industry, and an effective vaccine against HPAI is highly desirable. Live attenuated influenza vaccine with trunctated NS1 protein as a potential strategy will be extremely useful for improving immune efficacy. A series of H5N1 avian influenza virus reassortants harboring amino-terminal 48, 70, 73, and 99 aa in NS1 proteins, along with a modified low pathogenic HA protein was generated, and named as S-HALo/NS48, S-HALo/NS70, S-HALo/NS73, and S-HALo/NS99, respectively. In addition, their biological and immunological characteristics were further analyzed. The viruses S-HALo/NS70, S-HALo/NS73, and S-HALo/NS99, but not S-HALo/NS48, had a comparable growth property with the full-length NS1 virus, S-HALo/NSFu. Mice and chickens studies demonstrated that the viruses with truncated NS1 protein were further attenuated when compared to the virus S-HALo/NSFu. Vaccination with the virus S-HALo/NS73 in chickens induced significant cross-protection against homologous clade 2.3.4 H5 virus and heterologous clade 7.2, 2.3.2.1, and 2.3.4.4 H5 viruses. A 70-aa amino-terminal fragment of NS1 protein may be long enough for viral replication. The recombinant virus S-HALo/NS73 is a broad-spectrum live attenuated H5N1 avian influenza vaccine candidate in chickens. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Recombinant baculovirus vaccine containing multiple M2e and adjuvant LTB induces T cell dependent, cross-clade protection against H5N1 influenza virus in mice.

    PubMed

    Zhang, Jie; Fan, Hui-Ying; Zhang, Zhen; Zhang, Juan; Zhang, Jiao; Huang, Jian-Ni; Ye, Yu; Liao, Ming

    2016-01-27

    H5N1, highly pathogenic avian influenza poses, a threat to animal and human health. Rapid changes in H5N1 viruses require periodic reformulation of the conventional strain-matched vaccines, thus emphasizing the need for a broadly protective influenza vaccine. Here, we constructed BV-Dual-3M2e-LTB, a recombinant baculovirus based on baculovirus display and BacMam technology. BV-Dual-3M2e-LTB harbors a gene cassette expressing three tandem copies of the highly conserved extracellular domain of influenza M2 protein (M2e) and the mucosal adjuvant, LTB. We showed that BV-Dual-3M2e-LTB displayed the target protein (M2e/LTB) on the baculoviral surface and expressed it in transduced mammalian cells. BV-Dual-3M2e-LTB, when delivered nasally in mice, was highly immunogenic and induced superior levels of anti-M2e IgA than the non-adjuvanted baculovirus (BV-Dual-3M2e). Importantly, after challenge with different H5N1 clades (clade 0, 2.3.2.1, 2.3.4 and 4), mice inoculated with BV-Dual-3M2e-LTB displayed improved survival and decreased lung virus shedding compared with mice inoculated with BV-Dual-3M2e. The enhanced protection from BV-Dual-3M2e-LTB is mediated by T cell immunity and is primarily based on CD8(+) T cells, while mucosal antibodies alone were insufficient for protection from lethal H5N1 challenge. These results suggest that BV-Dual-3M2e-LTB has potential to protect against a broad range of H5N1 strains thereby providing a novel direction for developing broadly protective vaccines based on cellular immunity.

  4. Sterilization.

    PubMed

    Rioux, M H

    1979-05-01

    The history of sterilization in North America has included enactment of laws in 37 U. S. states and 2 Canadian provinces allowing the procedure to be performed to eliminate undesirable, genetically-transmitted traits. These eugenic laws applied to any of the following categories of persons: mentally regarded, mentally ill, epileptic, criminal, alcoholic, or poor people. Pressure from geneticists, lawyers, and others concerned with the implications of such laws, led to their repeal in many places. Noneugenic and nontherapeutic sterilization is today a recognized medical practice. Legally, such procedures must meet the following criteria: 1) informed consent; 2) individual benefit; and 3) performance with reasonable care and skill. If these criteria are met, doctors are protected from legal liability. The most legal, social, and ethical ambiguities arise in cases where nontherapeutic sterilization is performed on individuals unable to give consent, e.g., minors or mentally handicapped persons.

  5. Sterilization.

    PubMed

    Peterson, Herbert B

    2008-01-01

    Worldwide, sterilization (tubal sterilization and vasectomy) is used by more people than any other method of contraception. All techniques of tubal sterilization in widespread use in the United States have low risks of surgical complications. Although tubal sterilization is highly effective, the risk of pregnancy varies by age and method of occlusion. Pregnancies can occur many years after the procedure, and when they do, the risk of ectopic gestation is high. There is now strong evidence against the existence of a post-tubal ligation syndrome of menstrual abnormalities. Although women who have undergone tubal sterilization are more likely than other women to undergo hysterectomy subsequently, there is no known biologic basis for this relationship. Although sterilization is intended to be permanent, expressions of regret and requests for reversal are not uncommon and are much more likely to occur among women sterilized at young ages. Tubal sterilization has little or no effect on sexual function for most women. Vasectomy is less likely than tubal sterilization to result in serious complications. Minor complications, however, are not uncommon. Vasectomy does not increase the risk of heart disease, and available evidence argues against an increase in the risk of prostate cancer, testicular cancer, or overall mortality. Whether a postvasectomy pain syndrome exists remains controversial. Although the long-term effectiveness of vasectomy is less well-studied than that for tubal sterilization, it seems likely to be at least as effective. Intrauterine devices and progestin implants are long-acting, highly effective alternatives to sterilization.

  6. Acetaminophen hepatotoxicity and sterile inflammation: The mechanism of protection of Chlorogenic acid.

    PubMed

    Jaeschke, Hartmut

    2016-01-05

    Acetaminophen hepatotoxicity is characterized by extensive necrotic cell death and a sterile inflammatory response. A recent report suggested that a therapeutic intervention with chlorogenic acid, a dietary polyphenolic compound, protects against acetaminophen-induced liver injury by inhibiting the inflammatory injury. The purpose of this letter is to discuss a number of reasons why the protective mechanism of chlorogenic acid against acetaminophen hepatotoxicity does not involve an anti-inflammatory effect and provides an alternative explanation for the observed protection.

  7. A Nonintegrative Lentiviral Vector-Based Vaccine Provides Long-Term Sterile Protection against Malaria

    PubMed Central

    Coutant, Frédéric; Sanchez David, Raul Yusef; Félix, Tristan; Boulay, Aude; Caleechurn, Laxmee; Souque, Philippe; Thouvenot, Catherine; Bourgouin, Catherine

    2012-01-01

    Trials testing the RTS,S candidate malaria vaccine and radiation-attenuated sporozoites (RAS) have shown that protective immunity against malaria can be induced and that an effective vaccine is not out of reach. However, longer-term protection and higher protection rates are required to eradicate malaria from the endemic regions. It implies that there is still a need to explore new vaccine strategies. Lentiviral vectors are very potent at inducing strong immunological memory. However their integrative status challenges their safety profile. Eliminating the integration step obviates the risk of insertional oncogenesis. Providing they confer sterile immunity, nonintegrative lentiviral vectors (NILV) hold promise as mass pediatric vaccine by meeting high safety standards. In this study, we have assessed the protective efficacy of NILV against malaria in a robust pre-clinical model. Mice were immunized with NILV encoding Plasmodium yoelii Circumsporozoite Protein (Py CSP) and challenged with sporozoites one month later. In two independent protective efficacy studies, 50% (37.5–62.5) of the animals were fully protected (p = 0.0072 and p = 0.0008 respectively when compared to naive mice). The remaining mice with detectable parasitized red blood cells exhibited a prolonged patency and reduced parasitemia. Moreover, protection was long-lasting with 42.8% sterile protection six months after the last immunization (p = 0.0042). Post-challenge CD8+ T cells to CSP, in contrast to anti-CSP antibodies, were associated with protection (r = −0.6615 and p = 0.0004 between the frequency of IFN-g secreting specific T cells in spleen and parasitemia). However, while NILV and RAS immunizations elicited comparable immunity to CSP, only RAS conferred 100% of sterile protection. Given that a better protection can be anticipated from a multi-antigen vaccine and an optimized vector design, NILV appear as a promising malaria vaccine. PMID:23133649

  8. Sterile Protective Immunity to Malaria is Associated with a Panel of Novel P. falciparum Antigens*

    PubMed Central

    Trieu, Angela; Kayala, Matthew A.; Burk, Chad; Molina, Douglas M.; Freilich, Daniel A.; Richie, Thomas L.; Baldi, Pierre; Felgner, Philip L.; Doolan, Denise L.

    2011-01-01

    The development of an effective malaria vaccine remains a global public health priority. Less than 0.5% of the Plasmodium falciparum genome has been assessed as potential vaccine targets and candidate vaccines have been based almost exclusively on single antigens. It is possible that the failure to develop a malaria vaccine despite decades of effort might be attributed to this historic focus. To advance malaria vaccine development, we have fabricated protein microarrays representing 23% of the entire P. falciparum proteome and have probed these arrays with plasma from subjects with sterile protection or no protection after experimental immunization with radiation attenuated P. falciparum sporozoites. A panel of 19 pre-erythrocytic stage antigens was identified as strongly associated with sporozoite-induced protective immunity; 16 of these antigens were novel and 85% have been independently identified in sporozoite and/or liver stage proteomic or transcriptomic data sets. Reactivity to any individual antigen did not correlate with protection but there was a highly significant difference in the cumulative signal intensity between protected and not protected individuals. Functional annotation indicates that most of these signature proteins are involved in cell cycle/DNA processing and protein synthesis. In addition, 21 novel blood-stage specific antigens were identified. Our data provide the first evidence that sterile protective immunity against malaria is directed against a panel of novel P. falciparum antigens rather than one antigen in isolation. These results have important implications for vaccine development, suggesting that an efficacious malaria vaccine should be multivalent and targeted at a select panel of key antigens, many of which have not been previously characterized. PMID:21628511

  9. Tubal Sterilization

    MedlinePlus

    ... pregnancy. Tubal sterilization is a permanent form of birth control. It is one of the most effective options for preventing pregnancy. But it is difficult to reverse. It doesn’t protect against sexually ...

  10. Phi ({Phi}) and psi ({Psi}) angles involved in malarial peptide bonds determine sterile protective immunity

    SciTech Connect

    Patarroyo, Manuel E.; Moreno-Vranich, Armando; Bermudez, Adriana

    2012-12-07

    Highlights: Black-Right-Pointing-Pointer Phi ({Phi}) and psi ({Psi}) angles determine sterile protective immunity. Black-Right-Pointing-Pointer Modified peptide's tendency to assume a regular conformation related to a PPII{sub L}. Black-Right-Pointing-Pointer Structural modifications in mHABPs induce Ab and protective immunity. Black-Right-Pointing-Pointer mHABP backbone atom's interaction with HLA-DR{beta}1{sup Asterisk-Operator} is stabilised by H-bonds. -- Abstract: Modified HABP (mHABP) regions interacting with HLA-DR{beta}1{sup Asterisk-Operator} molecules have a more restricted conformation and/or sequence than other mHABPs which do not fit perfectly into their peptide binding regions (PBR) and do not induce an acceptable immune response due to the critical role of their {Phi} and {Psi} torsion angles. These angle's critical role was determined in such highly immunogenic, protection-inducing response against experimental malaria using the conformers (mHABPs) obtained by {sup 1}H-NMR and superimposed into HLA-DR{beta}1{sup Asterisk-Operator }-like Aotus monkey molecules; their phi ({Phi}) and psi ({Psi}) angles were measured and the H-bond formation between these molecules was evaluated. The aforementioned mHABP propensity to assume a regular conformation similar to a left-handed polyproline type II helix (PPII{sub L}) led to suggesting that favouring these conformations according to their amino acid sequence would lead to high antibody titre production and sterile protective immunity induction against malaria, thereby adding new principles or rules for vaccine development, malaria being one of them.

  11. Atomic force microscopy imaging reveals the formation of ASIC/ENaC cross-clade ion channels

    SciTech Connect

    Jeggle, Pia; Smith, Ewan St. J.; Stewart, Andrew P.; Haerteis, Silke; Korbmacher, Christoph; Edwardson, J. Michael

    2015-08-14

    ASIC and ENaC are co-expressed in various cell types, and there is evidence for a close association between them. Here, we used atomic force microscopy (AFM) to determine whether ASIC1a and ENaC subunits are able to form cross-clade hybrid ion channels. ASIC1a and ENaC could be co-isolated from detergent extracts of tsA 201 cells co-expressing the two subunits. Isolated proteins were incubated with antibodies against ENaC and Fab fragments against ASIC1a. AFM imaging revealed proteins that were decorated by both an antibody and a Fab fragment with an angle of ∼120° between them, indicating the formation of ASIC1a/ENaC heterotrimers. - Highlights: • There is evidence for a close association between ASIC and ENaC. • We used AFM to test whether ASIC1a and ENaC subunits form cross-clade ion channels. • Isolated proteins were incubated with subunit-specific antibodies and Fab fragments. • Some proteins were doubly decorated at ∼120° by an antibody and a Fab fragment. • Our results indicate the formation of ASIC1a/ENaC heterotrimers.

  12. Cross-clade neutralizing antibodies against HIV-1 induced in rabbits by focusing the immune response on a neutralizing epitope

    SciTech Connect

    Zolla-Pazner, Susan; Cohen, Sandra; Pinter, Abraham; Krachmarov, Chavdar; Wrin, Terri; Wang Shixia; Lu Shan

    2009-09-15

    Studies were performed to induce cross-clade neutralizing antibodies (Abs) by testing various combinations of prime and boost constructs that focus the immune response on structurally-conserved epitopes in the V3 loop of HIV-1 gp120. Rabbits were immunized with gp120 DNA containing a V3 loop characterized by the GPGR motif at its tip, and/or with gp120 DNA with a V3 loop carrying the GPGQ motif. Priming was followed by boosts with V3-fusion proteins (V3-FPs) carrying the V3 sequence from a subtype B virus (GPGR motif), and/or with V3 sequences from subtypes A and C (GPGQ motif). The broadest and most consistent neutralizing responses were generated when using a clade C gp120 DNA prime and with the V3{sub B}-FP boost. Immune sera displayed neutralizing activity in three assays against pseudoviruses and primary isolates from subtypes A, AG, B, C, and D. Polyclonal Abs in the immune rabbit sera neutralized viruses that were not neutralized by pools of human anti-V3 monoclonal Abs. Greater than 80% of the neutralizing Abs were specific for V3, showing that the immune response could be focused on a neutralizing epitope and that vaccine-induced anti-V3 Abs have cross-clade neutralizing activity.

  13. Fracture resistance behaviour of gamma-irradiation sterilized cortical bone protected with a ribose pre-treatment

    NASA Astrophysics Data System (ADS)

    Woodside, Carman Mitchell

    Structural bone allograft reconstructions are often implemented to repair large skeletal defects. To ensure the biological safety of the patient, allograft material is routinely sterilized with gamma-irradiation prior to implantation. The sterilization process damages the tissue, specifically the collagen protein network, leading to severe losses in the mechanical properties of the bone. Our lab has begun developing a ribose pre-treatment that can protect bone from these harmful effects. The goals of the present study were to develop a method to measure the fracture toughness of bone, an important clinical failure mode, and implement it to determine the effectiveness of the ribose pre-treatment on fracture toughness. We have shown that the ribose pre-treatment is successful at protecting some of the original fracture toughness of sterilized bone, and that the connectivity of the collagen network is an important contributor to the fracture resistance of bone.

  14. Plasma-Based Sterilization

    DTIC Science & Technology

    2003-07-20

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP014940 TITLE: Plasma-Based Sterilization DISTRIBUTION: Approved for...compilation report: ADP014936 thru ADP015049 UNCLASSIFIED Plasma-Based Sterilization Mounir Laroussi Electrical & Computer Engineering Department Old...Dominion University Norfolk, VA 23529 Rapid, safe, and effective sterilization is of the utmost importance when it comes to protecting the public in

  15. Sterile connector.

    PubMed

    Tenczar, F J

    1976-01-01

    Fabrication of a sterile connector for joining a supply source to an independent delivery location through a contaminated environment requires four design steps: 1) alignment of connector housings; 2) exclusion of the contaminated environment; 3) sterilization of the excluded region; and 4) penetration within the sterilized area followed by coupling of the protected internal conduits. Protective covers for connectors now in use may be modified to provide penetrable terminal barrier membranes that can be joined to exclude the environment. An adhesive containing an antimicrobiologic agent would set the stage for a controlled mechanical penetration of the decontaminated fused barriers. In another design concept, plastic barrier membranes without preliminary adhesions are simultaneously fused, sterilized, and penetrated by a nichrome wire heated to approximately 288 C. A system can be designed that is compatible, at the option of the user, with either of these methods. The more economical mechanical approach could then be used for parenteral fluid therapy while the nichrome wire technique would be reserved for more complex processing methods (frozen erythrocytes) or when storage of the resulting component is a factor.

  16. An Enhanced Synthetic Multiclade DNA Prime Induces Improved Cross-Clade-Reactive Functional Antibodies when Combined with an Adjuvanted Protein Boost in Nonhuman Primates

    PubMed Central

    Wise, Megan C.; Hutnick, Natalie A.; Pollara, Justin; Myles, Devin J. F.; Williams, Constance; Yan, Jian; LaBranche, Celia C.; Khan, Amir S.; Sardesai, Niranjan Y.; Montefiori, David; Barnett, Susan W.; Zolla-Pazner, Susan; Ferrari, Guido

    2015-01-01

    ABSTRACT The search for an efficacious human immunodeficiency virus type 1 (HIV-1) vaccine remains a pressing need. The moderate success of the RV144 Thai clinical vaccine trial suggested that vaccine-induced HIV-1-specific antibodies can reduce the risk of HIV-1 infection. We have made several improvements to the DNA platform and have previously shown that improved DNA vaccines alone are capable of inducing both binding and neutralizing antibodies in small-animal models. In this study, we explored how an improved DNA prime and recombinant protein boost would impact HIV-specific vaccine immunogenicity in rhesus macaques (RhM). After DNA immunization with either a single HIV Env consensus sequence or multiple constructs expressing HIV subtype-specific Env consensus sequences, we detected both CD4+ and CD8+ T-cell responses to all vaccine immunogens. These T-cell responses were further increased after protein boosting to levels exceeding those of DNA-only or protein-only immunization. In addition, we observed antibodies that exhibited robust cross-clade binding and neutralizing and antibody-dependent cellular cytotoxicity (ADCC) activity after immunization with the DNA prime-protein boost regimen, with the multiple-Env formulation inducing a more robust and broader response than the single-Env formulation. The magnitude and functionality of these responses emphasize the strong priming effect improved DNA immunogens can induce, which are further expanded upon protein boost. These results support further study of an improved synthetic DNA prime together with a protein boost for enhancing anti-HIV immune responses. IMPORTANCE Even with effective antiretroviral drugs, HIV remains an enormous global health burden. Vaccine development has been problematic in part due to the high degree of diversity and poor immunogenicity of the HIV Env protein. Studies suggest that a relevant HIV vaccine will likely need to induce broad cellular and humoral responses from a simple vaccine

  17. Inhibition of sterile danger signals, uric acid and ATP, prevents inflammasome activation and protects from alcoholic steatohepatitis in mice

    PubMed Central

    Iracheta-Vellve, Arvin; Petrasek, Jan; Satishchandran, Abhishek; Gyongyosi, Benedek; Saha, Banishree; Kodys, Karen; Fitzgerald, Katherine A.; Kurt-Jones, Evelyn A.; Szabo, Gyongyi

    2015-01-01

    Background & Aims The inflammasome is a well-characterized inducer of inflammation in ASH. Inflammasome activation requires two signals for mature interleukin (IL)-1β production. Here we asked whether metabolic danger signals trigger inflammasome activation in ASH. Methods Wild-type mice, ATP receptor 2×7 (P2rx7)-KO mice, or mice overexpressing uricase were fed Lieber-DeCarli ethanol or control diet. We also implemented a pharmacological approach in which mice were treated with probenecid or allopurinol. Results The sterile danger signals, ATP and uric acid, were increased in the serum and liver of alcohol-fed mice. Depletion of uric acid or ATP, or lack of ATP signaling attenuated ASH and prevented inflammasome activation and its major downstream cytokine, IL-1β. Pharmacological depletion of uric acid with allopurinol provided significant protection from alcohol-induced inflammatory response, steatosis and liver damage, and additional protection was achieved in mice treated with probenecid, which depletes uric acid and blocks ATP-induced P2rx7 signaling. We found that alcohol-damaged hepatocytes released uric acid and ATP in vivo and in vitro and that these sterile danger signals activated the inflammasome in LPS-exposed liver mononuclear cells. Conclusions Our data indicate that the second signal in inflammasome activation and IL-1β production in ASH results from the endogenous danger signals, uric acid and ATP. Inhibition of signaling triggered by uric acid and ATP may have therapeutic implications in ASH. PMID:26100496

  18. Comparison of different dry heat sterilization regimes for application in planetary protection

    NASA Astrophysics Data System (ADS)

    Kempf, M. J.; Schubert, W.; Spry, J.; Beaudet, R.

    Dry heat microbial reduction DHMR is the only NASA certified method for sterilization processing of robotic spacecraft Current requirements for dry heat microbial reduction as stated in NASA document NPR8020 12C stipulates a D-value time period at a single temperature point 125 C to claim credit for microbial reduction From a spacecraft design and assembly perspective this constraint can be problematic First it requires that the spacecraft or subassembly be inaccessible for an extended duration typically 30 hours plus set-up transit time to complete the DHMR process Second and often more importantly the elements of the spacecraft are exposed to an extended potentially damaging high temperature soak In the very least for many spacecraft components this type of elevated long duration elevated temperature processing will erode the operating life of the component In some cases elements of the craft may have already experienced non-certified high temperature processing during manufacture for which bioburden reduction credit could be taken if only the sterilization efficacy was known Examples include PCB manufacture and bake-outs of carbon composite structures The study ongoing in our laboratory aims to provide quantitative data on the bioburden reduction of Bacillus atrophaeus ATCC 9372 formerly Bacillus subtilis var niger BSN the reference organism for dry heat microbial reduction of spacecraft hardware under a broader range of conditions than the current certified method Data

  19. Postpartum Sterilization

    MedlinePlus

    ... How is postpartum sterilization performed? • What kind of anesthesia is used for postpartum sterilization? • How long does ... with stitches and a bandage. What kind of anesthesia is used for postpartum sterilization? Often, the type ...

  20. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  1. A ML29 Reassortant Virus Protects Guinea Pigs Against a Distantly-Related Nigerian Strain of Lassa Virus and can Provide Sterilizing Immunity

    PubMed Central

    Carrion, Ricardo; Patterson, Jean L.; Johnson, Curtis; Gonzales, Monica; Moreira, Carmen R.; Ticer, Anysha; Brasky, Kathleen; Hubbard, Gene B.; Moshkoff, Dmitry; Zapata, Juan; Salvato, Maria S.; Lukashevich, Igor S.

    2007-01-01

    Lassa virus (LASV) is responsible for the deaths of thousands of people in West Africa annually. Genetic diversity among LASV strains is the highest among the Arenaviridae and represents a great challenge for vaccine development. Guinea pigs vaccinated with a ML29 reassortant vaccine experienced sterilizing immunity and complete protection when challenged on day 30 either with homologous virus or with the distantly-related Nigerian isolate. Simultaneous vaccination-challenge or challenge on day 2 after vaccination also protected 60-100% of the animals against both strains, but without sterilizing immunity. These results indicate that simultaneous replication of ML29 and LASV attenuates the virulence of LASV infection. PMID:17360080

  2. A ML29 reassortant virus protects guinea pigs against a distantly related Nigerian strain of Lassa virus and can provide sterilizing immunity.

    PubMed

    Carrion, Ricardo; Patterson, Jean L; Johnson, Curtis; Gonzales, Monica; Moreira, Carmen R; Ticer, Anysha; Brasky, Kathleen; Hubbard, Gene B; Moshkoff, Dmitry; Zapata, Juan; Salvato, Maria S; Lukashevich, Igor S

    2007-05-16

    Lassa virus (LASV) is responsible for the deaths of thousands of people in West Africa annually. Genetic diversity among LASV strains is the highest among the Arenaviridae and represents a great challenge for vaccine development. Guinea pigs vaccinated with a ML29 reassortant vaccine experienced sterilizing immunity and complete protection when challenged on day 30 either with homologous virus or with the distantly related Nigerian isolate. Simultaneous vaccination-challenge or challenge on day 2 after vaccination also protected 60-100% of the animals against both strains, but without sterilizing immunity. These results indicate that simultaneous replication of ML29 and LASV attenuates the virulence of LASV infection.

  3. Cross-clade neutralization patterns among HIV-1 strains from the six major clades of the pandemic evaluated and compared in two different models.

    PubMed

    Brown, Bruce K; Wieczorek, Lindsay; Sanders-Buell, Eric; Rosa Borges, Andrew; Robb, Merlin L; Birx, Deborah L; Michael, Nelson L; McCutchan, Francine E; Polonis, Victoria R

    2008-06-05

    A panel of paired primary virus isolates and envelope pseudoviruses from sixty strains representing six HIV-1 clades was tested for neutralization using pooled, clade-specific plasma in two prominently utilized neutralization platforms: a primary isolate assay using peripheral blood mononuclear cells (PBMC) and a pseudovirus assay using a reporter epithelial cell line. Using the PMBC assay, pairing of the antibody pool against homologous clade viruses generated the highest geometric mean neutralizing antibody titer in 4 out of 6 clades tested, and neutralization patterns showed numerous examples of reciprocal cross-recognition between antibody and viruses of specific clade pairs. In the pseudovirus assay, cross-clade neutralization was more limited, with fewer distinct cross-clade relationships evident. The clade C antibody pool was broadly cross-reactive, neutralizing the greatest number of viruses in both assays. These data highlight the importance of the neutralization assay format employed and suggest that clade C envelopes merit further evaluation for the elicitation of broadly neutralizing antibodies.

  4. Sterile protection against Plasmodium knowlesi in rhesus monkeys from a malaria vaccine: comparison of heterologous prime boost strategies.

    PubMed

    Jiang, George; Shi, Meng; Conteh, Solomon; Richie, Nancy; Banania, Glenna; Geneshan, Harini; Valencia, Anais; Singh, Priti; Aguiar, Joao; Limbach, Keith; Kamrud, Kurt I; Rayner, Jonathan; Smith, Jonathan; Bruder, Joseph T; King, C Richter; Tsuboi, Takafumi; Takeo, Satoru; Endo, Yaeta; Doolan, Denise L; Richie, Thomas L; Weiss, Walter R

    2009-08-10

    Using newer vaccine platforms which have been effective against malaria in rodent models, we tested five immunization regimens against Plasmodium knowlesi in rhesus monkeys. All vaccines included the same four P. knowlesi antigens: the pre-erythrocytic antigens CSP, SSP2, and erythrocytic antigens AMA1, MSP1. We used four vaccine platforms for prime or boost vaccinations: plasmids (DNA), alphavirus replicons (VRP), attenuated adenovirus serotype 5 (Ad), or attenuated poxvirus (Pox). These four platforms combined to produce five different prime/boost vaccine regimens: Pox alone, VRP/Pox, VRP/Ad, Ad/Pox, and DNA/Pox. Five rhesus monkeys were immunized with each regimen, and five Control monkeys received a mock vaccination. The time to complete vaccinations was 420 days. All monkeys were challenged twice with 100 P. knowlesi sporozoites given IV. The first challenge was given 12 days after the last vaccination, and the monkeys receiving the DNA/Pox vaccine were the best protected, with 3/5 monkeys sterilely protected and 1/5 monkeys that self-cured its parasitemia. There was no protection in monkeys that received Pox malaria vaccine alone without previous priming. The second sporozoite challenge was given 4 months after the first. All 4 monkeys that were protected in the first challenge developed malaria in the second challenge. DNA, VRP and Ad5 vaccines all primed monkeys for strong immune responses after the Pox boost. We discuss the high level but short duration of protection in this experiment and the possible benefits of the long interval between prime and boost.

  5. Sterilization. Disciplined microbial control.

    PubMed

    Miller, C H

    1991-04-01

    The goal of instrument processing is to protect patients by preventing cross-contamination from instruments. The processing involves a series of sequential steps aimed at removing and killing microbes on contaminated instruments and maintaining those instruments in an aseptic state until they are reused. These steps must be conducted carefully to assure success and to reduce chances of disease spread or physical injury to those handling the contaminated instruments. Presoaking begins the cleaning process and facilitates terminal cleaning by ultrasonic or manual scrubbing. If instruments are not properly cleaned, subsequent sterilization may be jeopardized by insulation of blood- or saliva-coated microbes from the sterilizing agent. Items that would be destroyed by heat should be cleaned and sterilized in a properly prepared glutaraldehyde solution. Cleaned instruments must be packaged prior to heat sterilization to protect them from recontamination after sterilization and before reuse. Sterilization of cleaned, packaged instruments in steam, chemical vapor, or dry heat sterilizers must involve proper loading, processing, drying, and cooling. Routine use of spore tests and chemical indicators will provide quality assessment of packaging procedures and operation of the sterilizer, as well as assist in identifying processed packages during distribution. Using the results of sterilization monitoring to adjust procedures as a means of assuring sterilization provides quality assurance to the office staff and to the patients that the instruments have been properly processed. Carefully handling storage and distribution of the sterilized instrument packs or trays reduces the chances for recontamination until the instruments are reused. Instrument processing is a major part of the office infection control program. It must be performed in a controlled manner with proper monitoring to achieve the desired outcome of patient protection.

  6. IMMUNE SUPPRESSION OF CHALLENGED VACCINATES AS A RIGOROUS ASSESSMENT OF STERILE PROTECTION BY LENTIVIRAL VACCINES

    PubMed Central

    Craigo, Jodi K.; Durkin, Shannon; Sturgeon, Timothy J.; Tagmyer, Tara; Cook, Sheila J.; Issel, Charles J.; Montelaro, Ronald C.

    2007-01-01

    We previously reported that an experimental live-attenuated equine infectious anemia virus (EIAV) vaccine, containing a mutated S2 accessory gene, provided protection from disease and detectable infection after virulent virus (EIAVPV) challenge [1,2]. To determine if attenuated EIAV vaccines actually prevent persistent infection by challenge virus, we employed a 14-day dexamethasone treatment of vaccinated horses post-challenge to suppress host immunity and amplify replication levels of any infecting EIAV. At two months post-challenge the horses were all protected from virulent-virus challenge, evidenced by a lack of EIA signs and detectable challenge plasma viral RNA. Upon immune suppression, 6/12 horses displayed clinical EIA. Post-immune suppression characterizations demonstrated that the attenuated vaccine evidently prevented detectable challenge virus infection in 50% of horses. These data highlight the utility of post-challenge immune suppression for evaluating persistent viral vaccine protective efficacy. PMID:17023099

  7. Protein modification caused by a high dose of gamma irradiation in cryo-sterilized plasma: protective effects of ascorbate.

    PubMed

    Zbikowska, Halina M; Nowak, Pawel; Wachowicz, Barbara

    2006-02-01

    Gamma irradiation is a method of pathogen inactivation in plasma derivatives currently under development. Gamma rays inactivate all known blood-borne viruses. However, the virucidally effective dose of radiation may affect the integrity and function of plasma proteins. Biological activity recoveries of the therapeutic products were shown to be significantly improved by lowering the irradiation temperature and by the addition of antioxidants; the mechanisms responsible for this have not been elucidated yet. Here we sterilized human plasma by gamma irradiation (50 kGy), on dry ice, in the presence (or absence) of ascorbate. The subsequent protein oxidation was quantified by a ferric-xylenol orange (hydroperoxides) and by DNPH-coupled assays (carbonyls). We demonstrated for the first time that irradiation of frozen plasma (without saturation with oxygen) resulted in the generation of protein hydroperoxides, the yield of which was dramatically decreased when plasma was irradiated in the presence of either sodium azide or ascorbate. In irradiated plasma the concentration of protein carbonyls was twofold higher than in nonirradiated control. Ascorbate significantly inhibited protein carbonylation. We concluded that freezing of plasma during irradiation does not provide the complete protection against protein carbonylation and hydroperoxide generation. Addition of ascorbate and some nontoxic metabolic inhibitors might be useful as protecting stabilizers.

  8. Sterile protection against human malaria by chemoattenuated PfSPZ vaccine.

    PubMed

    Mordmüller, Benjamin; Surat, Güzin; Lagler, Heimo; Chakravarty, Sumana; Ishizuka, Andrew S; Lalremruata, Albert; Gmeiner, Markus; Campo, Joseph J; Esen, Meral; Ruben, Adam J; Held, Jana; Calle, Carlos Lamsfus; Mengue, Juliana B; Gebru, Tamirat; Ibáñez, Javier; Sulyok, Mihály; James, Eric R; Billingsley, Peter F; Natasha, K C; Manoj, Anita; Murshedkar, Tooba; Gunasekera, Anusha; Eappen, Abraham G; Li, Tao; Stafford, Richard E; Li, Minglin; Felgner, Phil L; Seder, Robert A; Richie, Thomas L; Sim, B Kim Lee; Hoffman, Stephen L; Kremsner, Peter G

    2017-02-23

    A highly protective malaria vaccine would greatly facilitate the prevention and elimination of malaria and containment of drug-resistant parasites. A high level (more than 90%) of protection against malaria in humans has previously been achieved only by immunization with radiation-attenuated Plasmodium falciparum (Pf) sporozoites (PfSPZ) inoculated by mosquitoes; by intravenous injection of aseptic, purified, radiation-attenuated, cryopreserved PfSPZ ('PfSPZ Vaccine'); or by infectious PfSPZ inoculated by mosquitoes to volunteers taking chloroquine or mefloquine (chemoprophylaxis with sporozoites). We assessed immunization by direct venous inoculation of aseptic, purified, cryopreserved, non-irradiated PfSPZ ('PfSPZ Challenge') to malaria-naive, healthy adult volunteers taking chloroquine for antimalarial chemoprophylaxis (vaccine approach denoted as PfSPZ-CVac). Three doses of 5.12 × 10(4) PfSPZ of PfSPZ Challenge at 28-day intervals were well tolerated and safe, and prevented infection in 9 out of 9 (100%) volunteers who underwent controlled human malaria infection ten weeks after the last dose (group III). Protective efficacy was dependent on dose and regimen. Immunization with 3.2 × 10(3) (group I) or 1.28 × 10(4) (group II) PfSPZ protected 3 out of 9 (33%) or 6 out of 9 (67%) volunteers, respectively. Three doses of 5.12 × 10(4) PfSPZ at five-day intervals protected 5 out of 8 (63%) volunteers. The frequency of Pf-specific polyfunctional CD4 memory T cells was associated with protection. On a 7,455 peptide Pf proteome array, immune sera from at least 5 out of 9 group III vaccinees recognized each of 22 proteins. PfSPZ-CVac is a highly efficacious vaccine candidate; when we are able to optimize the immunization regimen (dose, interval between doses, and drug partner), this vaccine could be used for combination mass drug administration and a mass vaccination program approach to eliminate malaria from geographically defined areas.

  9. Cross-clade cytotoxic T cell response to human immunodeficiency virus type 1 proteins among HLA disparate North Americans and Thais.

    PubMed

    Lynch, J A; deSouza, M; Robb, M D; Markowitz, L; Nitayaphan, S; Sapan, C V; Mann, D L; Birx, D L; Cox, J H

    1998-10-01

    A globally effective vaccine will need to elicit cytotoxic T lymphocytes (CTL) capable of recognizing diverse human immunodeficiency virus type 1 (HIV-1) clades. Study of the cellular immune responses of HIV-1-infected persons may allow predictions to be made regarding useful vaccine antigen components. The frequency and magnitude of CTL responses to clade E and B Gag, Pol-RT, Env, and Nef proteins were compared in 12 HLA-characterized, clade E-infected Thais and in 10 clade B-infected North Americans using vaccinia recombinant constructs for protein expression. While responses were detected against all proteins, they were most frequent and cross-reactive to Gag in both groups. Pol-RT was recognized less frequently in Thais than North Americans. Cross-clade protein recognition was common but not uniformly present among these HLA-disparate individuals. Population-specific CTL data are needed to adequately prepare for vaccine trials outside of North America and Europe.

  10. Reversible Sterilization

    ERIC Educational Resources Information Center

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  11. Reversible Sterilization

    ERIC Educational Resources Information Center

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  12. Secretion of Protective Antigens by Tissue-Stage Nematode Larvae Revealed by Proteomic Analysis and Vaccination-Induced Sterile Immunity

    PubMed Central

    Hewitson, James P.; Ivens, Al C.; Harcus, Yvonne; Filbey, Kara J.; McSorley, Henry J.; Murray, Janice; Bridgett, Stephen; Ashford, David; Dowle, Adam A.; Maizels, Rick M.

    2013-01-01

    Gastrointestinal nematode parasites infect over 1 billion humans, with little evidence for generation of sterilising immunity. These helminths are highly adapted to their mammalian host, following a developmental program through successive niches, while effectively down-modulating host immune responsiveness. Larvae of Heligmosomoides polygyrus, for example, encyst in the intestinal submucosa, before emerging as adult worms into the duodenal lumen. Adults release immunomodulatory excretory-secretory (ES) products, but mice immunised with adult H. polygyrus ES become fully immune to challenge infection. ES products of the intestinal wall 4th stage (L4) larvae are similarly important in host-parasite interactions, as they readily generate sterile immunity against infection, while released material from the egg stage is ineffective. Proteomic analyses of L4 ES identifies protective antigen targets as well as potential tissue-phase immunomodulatory molecules, using as comparators the adult ES proteome and a profile of H. polygyrus egg-released material. While 135 proteins are shared between L4 and adult ES, 72 are L4 ES-specific; L4-specific proteins correspond to those whose transcription is restricted to larval stages, while shared proteins are generally transcribed by all life cycle forms. Two protein families are more heavily represented in the L4 secretome, the Sushi domain, associated with complement regulation, and the ShK/SXC domain related to a toxin interfering with T cell signalling. Both adult and L4 ES contain extensive but distinct arrays of Venom allergen/Ancylostoma secreted protein-Like (VAL) members, with acetylcholinesterases (ACEs) and apyrase APY-3 particularly abundant in L4 ES. Serum antibodies from mice vaccinated with L4 and adult ES react strongly to the VAL-1 protein and to ACE-1, indicating that these two antigens represent major vaccine targets for this intestinal nematode. We have thus defined an extensive and novel repertoire of H

  13. The hepatitis B vaccine protects re-exposed health care workers, but does not provide sterilizing immunity.

    PubMed

    Werner, Jens M; Abdalla, Adil; Gara, Naveen; Ghany, Marc G; Rehermann, Barbara

    2013-11-01

    Infection with hepatitis B virus (HBV) can be prevented by vaccination with HB surface (HBs) antigen, which induces HBs-specific antibodies and T cells. However, the duration of vaccine-induced protective immunity is poorly defined for health care workers who were vaccinated as adults. We investigated the immune mechanisms (antibody and T-cell responses) of long-term protection by the HBV vaccine in 90 health care workers with or without occupational exposure to HBV, 10-28 years after vaccination. Fifty-nine of 90 health care workers (65%) had levels of antibodies to HBs antigen above the cut-off (>12 mIU/mL) and 30 of 90 (33%) had HBs-specific T cells that produced interferon-gamma. Titers of antibodies to HBs antigen correlated with numbers of HBs-specific interferon-gamma-producing T cells, but not with time after vaccination. Although occupational exposure to HBV after vaccination did not induce antibodies to the HBV core protein (HBcore), the standard biomarker for HBV infection, CD4(+) and CD8(+) T cells against HBcore and polymerase antigens were detected. Similar numbers of HBcore- and polymerase-specific CD4(+) and CD8(+) T cells were detected in health care workers with occupational exposure to HBV and in patients who acquired immunity via HBV infection. Most of the HBcore- and polymerase-specific T cells were CD45RO(+)CCR7(-)CD127(-) effector memory cells in exposed health care workers and in patients with acquired immunity. In contrast, most of the vaccine-induced HBs-specific T cells were CD45RO(-)CCR7(-)CD127(-) terminally differentiated cells. HBs antigen vaccine-induced immunity protects against future infection but does not provide sterilizing immunity, as evidenced by HBcore- and polymerase-specific CD8(+) T cells in vaccinated health care workers with occupational exposure to HBV. The presence of HBcore- and HBV polymerase-specific T-cell responses is a more sensitive indicator of HBV exposure than detection of HBcore-specific antibodies

  14. Sterilization System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  15. BASICS OF STERILE COMPOUNDING: Sterilization Methods in Sterile Product Manufacturing.

    PubMed

    Akers, Michael J

    2015-01-01

    Sterilization methods to produce sterile preparations include heat, gas, radiation, and filtration. This article focuses on heat, gas, and radiation sterilization, plus a brief introduction to bright-light sterilization. Microbiology basics and microbial death kinetics, key to understanding why these sterilization methods work, will also be briefly discussed. Filtration sterilization will be covered in a separate article.

  16. Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Palazzo, Antonio

    2016-05-01

    Several anomalies recorded in short-baseline neutrino experiments suggest the possibility that the standard 3-flavor framework may be incomplete and point towards a manifestation of new physics. Light sterile neutrinos provide a credible solution to these puzzling results. Here, we present a concise review of the status of the neutrino oscillations within the 3+1 scheme, the minimal extension of the standard 3-flavor framework endowed with one sterile neutrino species. We emphasize the potential role of LBL experiments in the searches of CP violation related to sterile neutrinos and their complementarity with the SBL experiments.

  17. A human antibody to the CD4 binding site of gp120 capable of highly potent but sporadic cross clade neutralization of primary HIV-1.

    PubMed

    Gach, Johannes S; Quendler, Heribert; Tong, Tommy; Narayan, Kristin M; Du, Sean X; Whalen, Robert G; Binley, James M; Forthal, Donald N; Poignard, Pascal; Zwick, Michael B

    2013-01-01

    Primary isolates of HIV-1 resist neutralization by most antibodies to the CD4 binding site (CD4bs) on gp120 due to occlusion of this site on the trimeric spike. We describe 1F7, a human CD4bs monoclonal antibody that was found to be exceptionally potent against the HIV-1 primary isolate JR-FL. However, 1F7 failed to neutralize a patient-matched primary isolate, JR-CSF even though the two isolates differ by <10% in gp120 at the protein level. In an HIV-1 cross clade panel (n = 157), 1F7 exhibited moderate breadth, but occasionally achieved considerable potency. In binding experiments using monomeric gp120s of select resistant isolates and domain-swap chimeras between JR-FL and JR-CSF, recognition by 1F7 was limited by sequence polymorphisms involving at least the C2 region of Env. Putative N-linked glycosylation site (PNGS) mutations, notably at position 197, allowed 1F7 to neutralize JR-CSF potently without improving binding to the cognate, monomeric gp120. In contrast, flow cytometry experiments using the same PNGS mutants revealed that 1F7 binding is enhanced on cognate trimeric Env. BN-PAGE mobility shift experiments revealed that 1F7 is sensitive to the diagnostic mutation D368R in the CD4 binding loop of gp120. Our data on 1F7 reinforce how exquisitely targeted CD4bs antibodies must be to achieve cross neutralization of two closely related primary isolates. High-resolution analyses of trimeric Env that show the orientation of glycans and polymorphic elements of the CD4bs that affect binding to antibodies like 1F7 are desirable to understand how to promote immunogenicity of more conserved elements of the CD4bs.

  18. Postpartum Sterilization

    MedlinePlus

    ... a few hours or days following delivery. For women who have had a cesarean delivery, it is done right after the baby is born. How is postpartum sterilization performed? For women who have had a vaginal delivery, a small ...

  19. Sterile neutrinos

    SciTech Connect

    Kopp, J.; Machado, P. A. N.

    2016-06-21

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  20. Sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Kopp, J.; Machado, P. A. N.; Maltoni, M.; Schwetz, T.

    2016-06-01

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  1. Review of Sterilization Techniques and Clinical Updates.

    PubMed

    Clark, Nisse V; Endicott, Scott P; Jorgensen, Elisa M; Hur, Hye-Chun; Lockrow, Ernest G; Kern, Mary E; Jones-Cox, Candice E; Dunlow, Susan G; Einarsson, Jon I; Cohen, Sarah L

    2017-09-19

    Sterilization is the most common form of contraception used worldwide and is highly effective in preventing unintended pregnancy. Several sterilization methods exist, each with unique advantages and disadvantages that influence the preferred approach for an individual patient. Salpingectomy for sterilization has popularized in recent years with mounting evidence suggesting a protective effect against ovarian cancers that originate from the fallopian tube. At the same time, Essure® hysteroscopic sterilization has come under scrutiny due to increasing reports of adverse effects that may be related to the device. This paper reviews clinical updates in sterilization, with a focus on salpingectomy and Essure hysteroscopic sterilization. Copyright © 2017. Published by Elsevier Inc.

  2. Cross-Clade Recognition of HIV-1 CAp24 by CD4+ T Cells in HIV-1-Infected Individuals in Burkina Faso and Germany

    PubMed Central

    Böhler, Thomas; Mrosek, Vanessa; Müller, Kerstin; Schnitzler, Paul; Hartmann, Martin; Ouedraogo, Thierry; Coulibaly, Boubacar; Sié, Ali; Bartonova, Vanda; Tebit, Denis M; Kräusslich, Hans-Georg

    2009-01-01

    The presence of antigen-specific cellular immune responses may be an indicator of long-term asymptomatic HIV-1-disease. The detection of cellular immune responses to infection with different subtypes of HIV-1 may be hampered by genetic differences of immunodominant antigens such as the capsid protein CAp24. In Nouna, Burkina Faso, HIV-1 circulating recombinant forms CRF02_AG and CRF06_cpx are the 2 major strains detectable in HIV-1-infected individuals, while subtype B strains prevail in Europe and North America. Amino acid sequences of CAp24 were assessed in blood samples from 10 HIV-1-infected patients in Nouna, Burkina Faso. Production of interferon-gamma (IFN-γ) in peripheral blood CD4+ lymphocytes in response to recombinant HIV-1 proteins derived from clade B (including CAp24NL4-3) was measured using a modified flow-cytometry-based whole blood short term activation assay (FASTimmune, BDBiosciences). IFN-γ production following stimulation with a whole length CAp24 protein derived from clade B (CAp24NL4-3) was additionally quantified in comparison to a CAp24 protein derived from CRF02_AG (CAp24BD6-15) in 16 HIV-1-infected patients in Heidelberg, Germany. Amino acid sequence identity of CAp24 obtained from patients in Nouna ranged between 86 and 89% when compared to the clade B CAp24NL4-3 consensus sequence, between 90 and 95% when compared to the circulating recombinant form CRF06_CPX consensus sequence, and between 92 and 96% when compared to the CAp24BD6-15 consensus sequence. Significant numbers of HIV-1-specific CD4+ lymphocytes producing IFN-γ were detected in 4 of 10 HIV-1-infected patients. In 7 of 16 patients in Heidelberg, recombinant CAp24BD6-15 stimulated IFN-γ-production in CD4+ lymphocytes to a similar extent as the clade B-derived CAp24NL4-3. Thus, antigen-specific CD4+ lymphocytes from both West African and European patients infected with different strains of HIV-1 show relevant cross-clade recognition of HIV-1 CAp24 in a flow

  3. DNA Prime/Adenovirus Boost Malaria Vaccine Encoding P. falciparum CSP and AMA1 Induces Sterile Protection Associated with Cell-Mediated Immunity

    PubMed Central

    Chuang, Ilin; Sedegah, Martha; Cicatelli, Susan; Spring, Michele; Polhemus, Mark; Tamminga, Cindy; Patterson, Noelle; Guerrero, Melanie; Bennett, Jason W.; McGrath, Shannon; Ganeshan, Harini; Belmonte, Maria; Farooq, Fouzia; Abot, Esteban; Banania, Jo Glenna; Huang, Jun; Newcomer, Rhonda; Rein, Lisa; Litilit, Dianne; Richie, Nancy O.; Wood, Chloe; Murphy, Jittawadee; Sauerwein, Robert; Hermsen, Cornelus C.; McCoy, Andrea J.; Kamau, Edwin; Cummings, James; Komisar, Jack; Sutamihardja, Awalludin; Shi, Meng; Epstein, Judith E.; Maiolatesi, Santina; Tosh, Donna; Limbach, Keith; Angov, Evelina; Bergmann-Leitner, Elke; Bruder, Joseph T.; Doolan, Denise L.; King, C. Richter; Carucci, Daniel; Dutta, Sheetij; Soisson, Lorraine; Diggs, Carter; Hollingdale, Michael R.; Ockenhouse, Christian F.; Richie, Thomas L.

    2013-01-01

    Background Gene-based vaccination using prime/boost regimens protects animals and humans against malaria, inducing cell-mediated responses that in animal models target liver stage malaria parasites. We tested a DNA prime/adenovirus boost malaria vaccine in a Phase 1 clinical trial with controlled human malaria infection. Methodology/Principal Findings The vaccine regimen was three monthly doses of two DNA plasmids (DNA) followed four months later by a single boost with two non-replicating human serotype 5 adenovirus vectors (Ad). The constructs encoded genes expressing P. falciparum circumsporozoite protein (CSP) and apical membrane antigen-1 (AMA1). The regimen was safe and well-tolerated, with mostly mild adverse events that occurred at the site of injection. Only one AE (diarrhea), possibly related to immunization, was severe (Grade 3), preventing daily activities. Four weeks after the Ad boost, 15 study subjects were challenged with P. falciparum sporozoites by mosquito bite, and four (27%) were sterilely protected. Antibody responses by ELISA rose after Ad boost but were low (CSP geometric mean titer 210, range 44–817; AMA1 geometric mean micrograms/milliliter 11.9, range 1.5–102) and were not associated with protection. Ex vivo IFN-γ ELISpot responses after Ad boost were modest (CSP geometric mean spot forming cells/million peripheral blood mononuclear cells 86, range 13–408; AMA1 348, range 88–1270) and were highest in three protected subjects. ELISpot responses to AMA1 were significantly associated with protection (p = 0.019). Flow cytometry identified predominant IFN-γ mono-secreting CD8+ T cell responses in three protected subjects. No subjects with high pre-existing anti-Ad5 neutralizing antibodies were protected but the association was not statistically significant. Significance The DNA/Ad regimen provided the highest sterile immunity achieved against malaria following immunization with a gene-based subunit vaccine (27%). Protection was

  4. Hysteroscopic sterilization.

    PubMed

    Cooper, J M

    1992-06-01

    After a brief history of sterilization, this article is devoted to hysteroscopic techniques and instrumentation, and a presentation of hysteroscopic sterilization techniques: electrocoagulation techniques, hysteroscopic injection of chemicals, and hysteroscopically directed placement of intratubal mechanical devices (ceramic plugs, polyethylene plugs, preformed silicone plugs, nylon intratubal plugs, and formed-in-place silicone rubber plugs. Problems are identified that are common to all hysteroscopic sterilization techniques. There are also practical considerations which limit the development of hysteroscopic sterilization techniques, and these considerations are presented. Various means have been used historically to block the tubal ostia, including the insertion of nitric acid in 1984, but it was not until 1927 that the hysteroscope was used for sterilization. Hysteroscopy itself was discovered in 1869 for diagnosis of intrauterine diseases. Even with the hysteroscope and the 1934 procedure of using an electric current in the tubal ostia, hysteroscopic sterilization was little used. In 1973 a convention was convened to discuss the use of the procedure and the ramifications. Currently, the hysteroscope is a modified cytoscope with a 4 mm wide telescope with a fore-oblique lens, a 7 mm wide metallic sheath, a fiberoptic bundle for transmission of light, and additional instruments for intrauterine manipulation or surgical intervention. Under local anesthesia, sterilization is effected by 1) destruction of the interstitial portion of the oviduct by thermal energy, 2) injection techniques for the delivery of sclerosing substances or tissue adhesives, or 3) mechanical occlusive devices or plugs to block the oviduct. Recent uterine, cervical, or adnexal infections and pregnancy prevent the performance of sterilization, because infections are exacerbated by the procedure. Uterine perforation is a complication. Other complications involve allergic reactions to the

  5. Effects of Drought Stress on Pollen Sterility, Grain Yield, Abscisic Acid and Protective Enzymes in Two Winter Wheat Cultivars

    PubMed Central

    Dong, Baodi; Zheng, Xin; Liu, Haipei; Able, Jason A.; Yang, Hong; Zhao, Huan; Zhang, Mingming; Qiao, Yunzhou; Wang, Yakai; Liu, Mengyu

    2017-01-01

    Drought stress induced pollen sterility is a detrimental factor reducing grain number in wheat. Exploring the mechanisms underlying pollen fertility under drought conditions could assist breeding high-yielding wheat cultivars with stress tolerance. Here, by using two Chinese wheat cultivars subjected to different levels of polyethylene glycol (PEG)-induced drought stress, possible links between pollen fertility and stress tolerance were analyzed under different levels of drought stress at the young microspore stage. In both cultivars, higher grain number reduction was observed under condition of lower water availability. Overall, the drought tolerant cultivar (Jinmai47) exhibited less grain number reduction than the drought sensitive cultivar (Shiluan02-1) under all stress conditions. Compared with Shiluan02-1, Jinmai47 exhibited superior physiological performance in terms of leaf photosynthetic rate, ear carbohydrate accumulation, pollen sink strength, pollen development and fertility under stress. Moreover, Jinmai47 showed a lower increase in endogenous abscisic acid in ears than Shiluan02-1. Furthermore, higher levels of superoxide dismutase (SOD) and peroxidase (POD) activities were also found in the drought tolerant cultivar Jinmai47 under PEG stress, compared with the drought sensitive cultivar Shiluan02-1. Changes in these physiological traits could contribute to better pollen development and male fertility, ultimately leading to the maintenance of grain number under drought stress. PMID:28676806

  6. A PORTABLE DENTAL STERILIZING CYLINDER

    DTIC Science & Technology

    The report describes an aluminum cylinder in which dental instruments could be sterilized under emergency field conditions and at the same time be...protected against corrosion. The procedure involves loading the cylinder with dental instruments, flushing it with ethylene oxide-Freon gas, closing it...and then immersing it in boiling water for l hour. In preliminary experiments with a prototype of the sterilizing cylinder, dental instruments were

  7. Protective effects of exercise in metabolic disorders are mediated by inhibition of mitochondrial-derived sterile inflammation.

    PubMed

    Peeri, Maghsoud; Amiri, Shayan

    2015-12-01

    While beneficial properties of physical activity and exercise on human health have been extensively reported in literature, the exact mechanism(s) underpinning impacts of exercise are not well understood. Focusing on metabolic disorders, as the main causes of social and economic burden in current century, exercise exhibited promising effects in prevention, alleviation and retardation of these disorders including, type 2 diabetes (T2D), Alzheimer's disease (AD), major depressive disorder (MDD) and obesity. Recent evidence has unmasked the role of mitochondrial dysfunction and chronic inflammation in pathophysiology of these disorders. Despite of the wealth of research on the etiology of metabolic disorders, intimate connections between these diseases, complex pathophysiology and their comorbidity still remains a challenging dilemma. In addition, although physical activity has improving effects on human health, it is not clear that how exercise is able to exert its modulatory effects on outcomes of metabolic disorders. Among several mechanisms, we assumed the hypothesis that exercise mitigates the production of mitochondrial-induced reactive oxygen species (ROS) and danger associated molecular patterns (DAMPs) as the main triggering factors for inflammasome formation. Since inflammasomes are of highly deleterious molecules relevant to pathogenesis of metabolic disorders, we hypothesized that beneficial effects of exercise may be associated with its ability to enhance the mitochondrial biogenesis and glucose transportation through generation of brain derived neurotrophic factor (BDNF). Also, we proposed that boosting impact of exercise on autophagy process accelerates the elimination of damaged mitochondria and thus, results in considerable decrease in production of ROS and DAMPs and consequently sterile inflammation.

  8. Laying-up of sterile instruments in the operating theatre: equal or superior protection by using a horizontal unidirectional air flow system.

    PubMed

    Traversari, A A L; Goedhart, C A; Dusseldorp, E; Bode, A; Keuning, F; Pelk, M S J; Vos, M C

    2013-10-01

    A system for the preparation of sterilized instruments with unidirectional horizontal air flow (UDHF) has several advantages over a unidirectional down flow system (UDDF). The advantages are based on the installation of the system being more flexible and easier to use, no cooling of the air flow being necessary and less air being needed for circulation, resulting in reduced energy use. The objective of this study was to determine whether a system with UDHF performs equal or superior to a system with UDDF in terms of prevention of contamination of the air (the presence of particles and micro-organisms) during the laying-up process. The degree of protection (DP) offered by two UDHF system variants and two UDDF system variants was determined for several static set-ups and a dynamic simulation of the process. In addition to determining the level of protection for several categories of particle size, colony-forming units (CFU) were also measured during process simulations. When maximum protection (no particles present) is considered, the UDHF systems performed significantly better than the UDDF systems for particles ≥2.5μm. When particles were present, there was no significant difference between systems for particles ≥0.3 and ≥0.5μm. However, the performance of the UDHF system was superior to that of the UDDF system (DP) for particles ≥1.0μm representing the bacteria-carrying particles. During the process measurements, no CFU were found with the UDDF system in 64% of the measurements, compared with 90% for the UDHF system (P = 0.012). The UDHF system offers equal or superior protection to the UDDF system against contamination of the clean area within which the laying up takes place. Despite our finding that the differences did not always reach statistical significance (due to low background concentrations), there is a clear trend, from the small-sized particles (≥1.0μm) up to the largest sizes considered, including bacteria-carrying particles, that

  9. The effect of the radio-protective agents ethanol, trimethylglycine, and beer on survival of X-ray-sterilized male Aedes aegypti

    PubMed Central

    2013-01-01

    Background Sterile Insect Technique (SIT) has been successfully implemented to control, and in some cases, eradicate, dipteran insect populations. SIT has great potential as a mosquito control method. Different sterilization methods have been used on mosquitoes ranging from chemosterilization to genetically modified sterile male mosquito strains; however, sterilization with ionizing radiation is the method of choice for effective sterilization of male insects for most species. The lack of gentle radiation methods has resulted in significant complications when SIT has been applied to mosquitoes. Several studies report that irradiating mosquitoes resulted in a decrease in longevity and mating success compared to unirradiated males. The present study explored new protocols for mosquito sterilization with ionizing radiation that minimized detrimental effects on the longevity of irradiated males. Methods We tested three compounds that have been shown to act as radioprotectors in the mouse model system - ethanol, trimethylglycine, and beer. Male Aedes aegypti were treated with one of three chosen potential radioprotectors and were subsequently irradiated with identical doses of long-wavelength X-rays. We evaluated the effect of these radioprotectors on the longevity of male mosquito after irradiation. Results We found that X-ray irradiation with an absorbed dose of 1.17 gy confers complete sterility. Irradiation with this dose significantly shortened the lifespan of male mosquitoes and all three radioprotectors tested significantly enhanced the lifespan of irradiated mosquito males. Conclusion Our results suggest that treatment with ethanol, beer, or trimethylglycine before irradiation can be used to enhance longevity in mosquitoes. PMID:23866939

  10. Heat sterilization times of red pine boards

    Treesearch

    William T. Simpson

    2004-01-01

    The objective of this study was to determine the time required to heat the center of red pine boards to various temperatures for sterilization. This information will serve as a guideline for those concerned with heat sterilizing wood pallets and other wood shipping containers to meet heat treatment requirements for protection against invasive pests. Red pine boards, 4...

  11. [Optimal terms for sterilization].

    PubMed

    Ribic-Pucelj, M

    1980-01-01

    Sterilization can be performed in the immediate postpartum, post abortion, or as an interval procedure. Traditionally, postpartum sterilization should be performed within the first two days after delivery, thereafter the risk for infection is believed to increase. Sterilization and artificial abortion are performed as concomitant procedures, while interval sterilization is carried out at least six weeks after the termination of pregnancy. Though many authors consider the sterilization in the immediate postpartum and postabortion period safe enough, the comparative studies show that interval sterilization has less complications. Postpartum (postabortion) sterilization has much more disadvantages than advantages in comparison to interval sterilization. The main advantage of postpartum sterilization is only one hospitalization while disadvantages are the increased risk of hemorrhage, uterine perforation, thromboembolic disease, infection, technical difficulties, and psychological problems. For these reasons interval sterilization is recommended.

  12. Implementing AORN recommended practices for selection and use of packaging systems for sterilization.

    PubMed

    Morton, Paula J; Conner, Ramona

    2014-04-01

    The delivery of sterile products to the sterile field is essential to perioperative practice. The use of protective packaging for sterilized items is crucial to helping ensure that patients receive sterile items for surgical procedures. AORN's "Recommended practices for selection and use of packaging systems for sterilization" offers guidance to perioperative team members in evaluating, selecting, and using packaging systems that permit sterilization of the contents, prevent contamination of sterilized items until the package is opened for use, protect the items from damage during transport and storage, and permit aseptic delivery of the items to the sterile field.

  13. Rationally Designed Vaccines Targeting the V2 Region of HIV-1 gp120 Induce a Focused, Cross-Clade-Reactive, Biologically Functional Antibody Response.

    PubMed

    Zolla-Pazner, Susan; Powell, Rebecca; Yahyaei, Sara; Williams, Constance; Jiang, Xunqing; Li, Wei; Lu, Shan; Wang, Shixia; Upadhyay, Chitra; Hioe, Catarina E; Totrov, Max; Kong, Xiangpeng

    2016-12-15

    Strong antibody (Ab) responses against V1V2 epitopes of the human immunodeficiency virus type 1 (HIV-1) gp120 envelope (Env) correlated with reduced infection rates in studies of HIV, simian-human immunodeficiency virus (SHIV), and simian immunodeficiency virus (SIV). In order to focus the Ab response on V1V2, we used six V1V2 sequences and nine scaffold proteins to construct immunogens which were tested using various immunization regimens for their ability to induce cross-reactive and biologically active V2 Abs in rabbits. A prime/boost immunization strategy was employed using gp120 DNA and various V1V2-scaffold proteins. The rabbit polyclonal Ab responses (i) were successfully focused on the V1V2 region, with weak or only transient responses to other Env epitopes, (ii) displayed broad cross-reactive binding activity with gp120s and the V1V2 regions of diverse strains from clades B, C, and E, (iii) included V2 Abs with specificities similar to those found in HIV-infected individuals, and (iv) remained detectable ≥1 year after the last boosting dose. Importantly, sera from rabbits receiving V1V2-scaffold immunogens displayed Ab-dependent cellular phagocytosis whereas sera from rabbits receiving only gp120 did not. The results represent the first fully successful example of reverse vaccinology in the HIV vaccine field with rationally designed epitope scaffold immunogens inducing Abs that recapitulate the epitope specificity and biologic activity of the human monoclonal Abs from which the immunogens were designed. Moreover, this is the first immunogenicity study using epitope-targeting, rationally designed vaccine constructs that induced an Fc-mediated activity associated with protection from infection with HIV, SIV, and SHIV. Novel immunogens were designed to focus the antibody response of rabbits on the V1V2 epitopes of HIV-1 gp120 since such antibodies were associated with reduced infection rates of HIV, SIV, and SHIV. The vaccine-induced antibodies were broadly

  14. Sterilization of glycerin.

    PubMed

    McCluskey, Susan V

    2008-06-15

    The sterilization of glycerin is described. Glycerin is used in a wide variety of pharmaceutical formulations, including oral, otic, ophthalmic, topical, and parenteral preparations. Of the myriad uses for glycerin, some require a sterile solution. Due to the nature of dry heat sterilization with resulting equipment and validation needs, sterile filtration is the preferred sterilization method for glycerin at the Mayo Clinic Pharmacy Services Production Laboratory in Rochester, Minnesota. A practical procedure was attained with the use of a chemically compatible 0.22-microm capsule filter, peristaltic pump, and sterile tubing. The sterile tubing is attached firmly, with a twisting motion, to the hose barb ends of the filter. The peristaltic pump is set at minimum speed, and a sterile syringe is used to capture the sterile glycerin filtrate. After filtration, filter integrity testing using the bubble point test is performed on the filter used to sterilize the solution. Packaging was then completed by placing glycerin aliquots into unit-of-use sterile syringes, placing a sterile tip cap on each syringe, and labeling the syringe. End testing is needed for preparations, such as sterile glycerin, that are made from nonsterile components, regardless of sterilization technique. This quality-control testing includes but is not limited to visual checks, pH checks, and tests for bacterial endotoxins, particulate matter, and sterility. Beyond-use dating is then assigned based on chemical, physical, microbiological, and packaging considerations. A practical method for sterilization of glycerin by compounding pharmacists is attainable through the use of membrane filtration. Sterility assurance is achieved through appropriate validation, and quality-control checks must be completed before release of the injectable preparation.

  15. Characterization of cross-clade monoclonal antibodies against H5N1 highly pathogenic avian influenza virus and their application to the antigenic analysis of diverse H5 subtype viruses.

    PubMed

    Gronsang, Dulyatad; Bui, Anh N; Trinh, Dai Q; Bui, Vuong N; Nguyen, Khong V; Can, Minh X; Omatsu, Tsutomu; Mizutani, Tetsuya; Nagai, Makoto; Katayama, Yukie; Thampaisarn, Rapeewan; Ogawa, Haruko; Imai, Kunitoshi

    2017-08-01

    H5N1 highly pathogenic avian influenza viruses (HPAIVs) are a threat to both animal and public health and require specific and rapid detection for prompt disease control. We produced three neutralizing anti-hemagglutinin (HA) monoclonal antibodies (mAbs) using two clades (2.2 and 2.5) of the H5N1 HPAIV isolated in Japan. Blocking immunofluorescence tests showed that each mAb recognized different epitopes; 3B5.1 and 3B5.2 mAbs against the clade 2.5 virus showed cross-clade reactivity to all 26 strains from clades 1, 2.2, 2.3.2.1, 2.3.2.1a, b, c and 2.3.4, suggesting that the epitope(s) recognized are conserved. Conversely, the 1G5 mAb against the clade 2.2 virus showed reactivity to only clades 1, 2.3.4 and 2.5 strains. An analysis of escape mutants, and some clades of the H5N1 viruses recognized by 3B5.1 and 3B5.2 mAbs, suggested that the mAbs bind to an epitope, including amino acid residues at position 162 in the HA1 protein (R162 and K162). Unexpectedly, however, when five Eurasian-origin H5 low-pathogenic AIV (LPAIV) strains with R162 were examined (EA-nonGsGD clade) as well as two American-origin strains (Am-nonGsGD clade), the mAb recognized only EA-nonGsGD clade strains. The R162 and K162 residues in the HA1 protein were highly conserved among 36 of the 43 H5N1 clades reported, including clades 2.3.2.1a and 2.3.2.1c that are currently circulating in Asia, Africa and Europe. The amino acid residues (158-PTIKRSYNNTNQE-170) in the HA1 protein are probably an epitope responsible for the cross-clade reactivity of the mAbs, considering the epitopes reported elsewhere. The 3B5.1 and 3B5.2 mAbs may be useful for the specific detection of H5N1 HPAIVs circulating in the field.

  16. Sterilizing the Poor

    ERIC Educational Resources Information Center

    Rothman, Sheila M.

    1977-01-01

    Suggests that freedom for the middle classes may mean vulnerability for the poor. The enthusiasm for sterilization may be so intense as to deprive the poor of their right not to be sterilized. (Author/AM)

  17. [Complications of tubal sterilization].

    PubMed

    Schreiner, W E

    1986-05-01

    In Europe and the US, tubal sterilization by laparoscopy has become the most widely used technique for female sterilization. The overall rate of intra- and postoperative complications differs between 0.145% and 0.85% in the numerous studies which have been done. This means 1 severe complication in 120-700 laparoscopic sterilizations. The lethality of tubal sterilization by laparoscopy lies between 3-10 deaths/100,000 interventions. The so-called "post-tubal ligation syndrome" is a rare complication. The overall pregnancy rate after tubal sterilization is 3-10/1000 women. The rate of ectopic pregnancy is very high and varies between 13.6% and 90%. Only 5% of the sterilized women show dissatisfaction. Several factors are relevant with regard to psychological sequelae and must be considered before tubal sterilization can be performed. 1 of the most important is the individual comprehensive counselling of the female or the couple prior to the sterilization.

  18. Apparatus Circulates Sterilizing Gas

    NASA Technical Reports Server (NTRS)

    Cross, John H.; Schwarz, Ray P.

    1991-01-01

    Apparatus circulates sterilizing gas containing ethylene oxide and chlorofluorocarbon through laboratory or medical equipment. Confines sterilizing gas, circulating it only through parts to be treated. Consists of two units. One delivers ethylene oxide/chlorofluorocarbon gas mixture and removes gas after treatment. Other warms, humidifies, and circulates gas through equipment to be treated. Process provides reliable sterilization with negligible residual toxicity from ethylene oxide. Particularly suitable for sterilization of interiors of bioreactors, heart/lung machines, dialyzers, or other equipment including complicated tubing.

  19. The backcross sterility technique

    Treesearch

    V. C. Mastro; A. Pellegrini-Toole

    1991-01-01

    The sterile insect technique (SIT) and the induced inherited (F1) sterility technique have been investigated for a number of lepidopterous pests, including the gypsy moths. Another technique, backcross sterility, which could potentially prove as or more useful for control of pest species has been developed for the control of only one lepidopteran...

  20. Eugenics and Involuntary Sterilization: 1907-2015.

    PubMed

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  1. Another look at sterilization.

    PubMed

    Willson, P D

    1977-03-01

    R.T. Ravenhol, Director of Office of Population at the U.S. Agency for International Development (AID), reports that voluntary sterilization is currently the foremost means of fertility control in the world. According to AID estimates, 65,000,000 couples had chosen voluntary sterilization by the end of 1975. In order to expand its support for voluntary sterilization, AID wants to offer more of its resources to services, equipment, biomedical research, physician training, and public education. The International Project of the Association for Voluntary Sterilization has been most active in the provision of voluntary sterilization. Funded by AID it has spent over $6 million on voluntary sterilization services, equipment, physician training, and conferences in over 50 countries since it was established in 1972. There is concern that the current acceptance of voluntary sterilization maybe jeopardized by lack of understanding about and sensitivity to sterilization's use. Voluntary and compulsory sterilization are at opposite ends of a spectrum, and for those involved in family planning in developing countries, there is the question of whether there is really massive demand for voluntary sterilization in developing countries and whether sterilization is truly voluntary. There has also been concern about voluntarism and informed consent in the U.S. domestic programs, and this has affected international projects. To stress the importance of voluntarism, AID contracts and grants, effective 1977, must include an extensive statement regarding voluntarism to ensure compliance with the court decision prohibiting federally funded sterilizations for minors and mental or legal incompetents. Additionally, AID contracts must require documented informed consent, and individuals choosing sterilizations need to receive a description of the risks and benefits as well as a statement that the procedure is irreversible.

  2. Induction of cross clade reactive specific antibodies in mice by conjugates of HGP-30 (peptide analog of HIV-1(SF2) p17) and peptide segments of human beta-2-microglobulin or MHC II beta chain.

    PubMed

    Zimmerman, D H; Lloyd, J P; Heisey, D; Winship, M D; Siwek, M; Talor, E; Sarin, P S

    2001-09-14

    HGP-30, a 30 amino acid synthetic peptide homologous to a conserved region of HIV-1(SF2) p17 (aa86-115), has previously been shown to elicit both cellular and humoral immune responses when conjugated to KLH and adsorbed to alum. However, the free HGP-30 peptide is not immunogenic in animals. In order to improve the immunogenicity of HGP-30, peptide conjugates consisting of a modified HGP-30 sequence (m-HGP-30/aa82-111) and a peptide segment, residues 38-50, of the MHC I accessory molecule, human beta-2-microglobulin (beta-2-M), referred to as Peptide J, or a peptide from the MHC II beta chain (peptide G) were evaluated in mice. The effects of carriers and adjuvants on serum antibody titers, specificities to various HIV-1 clade peptides similar to HGP-30 and isotype patterns were examined. Peptides J or especially G conjugated to modified-HGP-30 (LEAPS 102 and LEAPS 101, respectively) generated comparable or better immune responses to modified HGP-30 than KLH conjugates as judged by the induction of: (1) similar antibody titers; (2) broader HIV clade antigen binding; and (3) antibody isotype response patterns indicative of a TH1 pathway (i.e. increased amounts of IgG2a and IgG2b antibodies). The ISA 51 and MPL(R)-SE adjuvants induced higher antibody responses than alum, with the ISA 51 being more potent. Immune responses to LEAPS 102, as compared to LEAPS 101, were weaker and slower to develop as determined by antibody titers and cross clade reactivity of the antibodies induced. Compared to KLH conjugates which induced significant anti-KLH antibody titers, minimal antibody responses were observed to peptide G, the more immunogenic conjugate, and peptide J. These results suggest that modified HGP-30 L.E.A.P.S. constructs may be useful as HIV vaccine candidates for preferential induction of TH1 directed cell mediated immune responses.

  3. [Sterilization of women].

    PubMed

    Hirsch, H A

    1984-09-01

    Voluntary sterilization is a permanent method of contraception. Therefore medical counseling of patients desiring sterilization is of utmost importance and should include documented incidence of failure (i.e., pregancy), complication risks, and if necessary, the various factors influencing successful reversal, although it should be emphasized that reversal can never be guaranteed. Laproscopic sterilization has proven very successful. Comparison of the advantages and disadvantages of the most used methods appears in Table 7. The most commonly used method is bipolar electrocoagulation in the isthmic tubal section. Unipolar electrocoagulation should not be used. Hysterectomy is too major an operation to be used solely for sterilization purposes, and is indicated only when other procedures have been eliminated. Pregnancy in failed sterilizations is approximately 8-10/1000 using the current methods, and an overwhelming number of these pregnancies are extrauterine. The rate of complications is lowest in laparoscopic interval sterilizations using local anesthesia. Approximately 1% of sterilized women desired reversal, despite preoperative counseling. The success rate of reversal is most favorable when the sterilization was perfomed in the isthmic tubal section with little destruction of tissue (by the clip method), the tubal segments are long, and the time since sterilization is less than 5 years. Reversal is not possible after fimbriectomy.

  4. [Sterilization and eugenics].

    PubMed

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  5. Transgenic Parasites Stably Expressing Full-Length Plasmodium falciparum Circumsporozoite Protein as a Model for Vaccine Down-Selection in Mice Using Sterile Protection as an Endpoint

    PubMed Central

    Porter, Michael D.; Nicki, Jennifer; Pool, Christopher D.; DeBot, Margot; Illam, Ratish M.; Brando, Clara; Bozick, Brooke; De La Vega, Patricia; Angra, Divya; Spaccapelo, Roberta; Crisanti, Andrea; Murphy, Jittawadee R.; Bennett, Jason W.; Schwenk, Robert J.; Ockenhouse, Christian F.

    2013-01-01

    Circumsporozoite protein (CSP) of Plasmodium falciparum is a protective human malaria vaccine candidate. There is an urgent need for models that can rapidly down-select novel CSP-based vaccine candidates. In the present study, the mouse-mosquito transmission cycle of a transgenic Plasmodium berghei malaria parasite stably expressing a functional full-length P. falciparum CSP was optimized to consistently produce infective sporozoites for protection studies. A minimal sporozoite challenge dose was established, and protection was defined as the absence of blood-stage parasites 14 days after intravenous challenge. The specificity of protection was confirmed by vaccinating mice with multiple CSP constructs of differing lengths and compositions. Constructs that induced high NANP repeat-specific antibody titers in enzyme-linked immunosorbent assays were protective, and the degree of protection was dependent on the antigen dose. There was a positive correlation between antibody avidity and protection. The antibodies in the protected mice recognized the native CSP on the parasites and showed sporozoite invasion inhibitory activity. Passive transfer of anti-CSP antibodies into naive mice also induced protection. Thus, we have demonstrated the utility of a mouse efficacy model to down-select human CSP-based vaccine formulations. PMID:23536694

  6. Plasma-Aided Sterilization*

    NASA Astrophysics Data System (ADS)

    Laroussi, Mounir; Rader, Mark; Dyer, Fred; Dever, Maureen; Alexeff, Igor

    1996-11-01

    The use of plasma as a sterilization agent was known for some time.In this paper we present recent work using atmospheric pressure plasmas to sterilize liquid and solid matter: The plasma can be a glow discharge or a corona discharge. The results show that sterilization occurs with treatment times which vary from a few seconds to a few minutes. The forseen applications of this method are in the medical, pharmaceutical, and food packaging industry. *Work supported in part by The Air Force Office of Scientific Research.

  7. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent...

  8. Breadth of humoral response and antigenic targets of sporozoite-inhibitory antibodies associated with sterile protection induced by controlled human malaria infection

    PubMed Central

    Peng, Kaitian; Goh, Yun Shan; Siau, Anthony; Franetich, Jean-François; Chia, Wan Ni; Ong, Alice Soh Meoy; Malleret, Benoit; Wu, Ying Ying; Snounou, Georges; Hermsen, Cornelus C.; Adams, John H.; Mazier, Dominique; Preiser, Peter R.; Sauerwein, Robert W.; Grüner, Anne-Charlotte; Rénia, Laurent

    2017-01-01

    The development of an effective malaria vaccine has remained elusive even until today. This is due to our incomplete understanding of the immune mechanisms that confer and/or correlate with protection. Human volunteers have been protected experimentally from a subsequent challenge by immunization with Plasmodium falciparum sporozoites under drug cover. Here, we demonstrate that sera from the protected individuals contain neutralizing antibodies against the pre erythrocytic stage. To identify the antigen(s) recognized by these antibodies, a newly developed library of P. falciparum antigens was screened with the neutralizing sera. Antibodies from protected individuals recognized a broad antigenic repertoire of which three antigens, PfMAEBL, PfTRAP and PfSEA1 were recognized by most protected individuals. As a proof of principle, we demonstrated that anti-PfMAEBL antibodies block liver stage development in human hepatocytes. Thus, these antigens identified are promising targets for vaccine development against malaria. PMID:27130708

  9. Sterilization of space hardware.

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  10. Sterilization of space hardware.

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  11. Female Sterilization (Tubal Ligation)

    MedlinePlus

    ... when you want to have it done. Some women are sterilized right after they have a baby or an abortion, ... videos on Youtube © 1998-2017 | Center for Young Women's Health, Boston Children's Hospital. All rights reserved.

  12. Auditing radiation sterilization facilities

    NASA Astrophysics Data System (ADS)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  13. Georgia Supreme Court invalidates involuntary sterilization statute.

    PubMed

    Harper, T D

    1983-11-01

    In the US, the concept of eugenics has been limited to restrictions on the reproductive capabilities of criminals and the mentally defective. Moreover, the rights of persons subject to this restriction have been enhanced by recent judicial recognition of procreation as a fundamental right. Constitutional challenges have been mounted on the grounds that sterilization statutes constitute cruel or unusual punishment, a violation of the Equal Protection clause, an unlawful delegation of legislative or judicial powers, a bill of attainder, or a violation of the right to life, liberty, and the pursuit of happiness. These challenges have resulted in a reduction in the number of state-mandated sterilizations. This paper reviews the Georgia Supreme Court's recent invalidation of a 1970 statute authorizing the sterilization of mentally incompetent persons (O.C.G.A. 31-20-3). Motes v. Hall County Department of Family and Children Services, filed on behalf of a 21-year old retarded woman, challenged the statute as a violation of Motes' constitutional rights to due process and equal protection and contended that the state was required to prove the necessity of sterilization by more than a simple preponderance of the evidence. The Georgia Supreme Court negated both the sterilization order and the statute upon which it was based. In its decision, the Court recognized that an intrusion upon so fundamental a right as the ability to bear children requires proof by the state of at least "clear and convincing evidence" of the necessity of such an act.

  14. The abundance of sterile transcripts in Giardia lamblia

    PubMed Central

    Elmendorf, Heidi G.; Singer, Steven M.; Nash, Theodore E.

    2001-01-01

    The protozoan parasite Giardia lamblia synthesizes a diverse and surprisingly abundant array of sterile transcripts unable to code for proteins. Random sampling of cDNAs from two evolutionarily divergent Giardia strains indicates that ∼20% of cDNAs in the libraries represent polyadenylated sterile transcripts. RNase protection analysis and northern blot hybridization of three sterile transcript loci demonstrated that both the sterile transcript and a complementary mRNA were made in each case, further categorizing these sterile transcripts as antisense transcripts. Investigation of the genomic loci for these same three sterile antisense transcripts showed typical transcription units for the sense transcripts, but still failed to reveal a usable open reading frame for the sterile antisense transcripts. 5′-RACE mapped the transcription start site for one of the sterile antisense transcripts to an AT-rich region, as is typical for Giardia. It is unclear whether these sterile transcripts represent errors in transcription or whether they have regulatory functions within the cell, although preliminary investigations failed to reveal evidence for a role in developmental gene regulation. In either case, the presence of such a large pool of sterile antisense transcripts is dramatic evidence of the unusual molecular machinery of the early diverging protist G.lamblia. PMID:11713317

  15. The abundance of sterile transcripts in Giardia lamblia.

    PubMed

    Elmendorf, H G; Singer, S M; Nash, T E

    2001-11-15

    The protozoan parasite Giardia lamblia synthesizes a diverse and surprisingly abundant array of sterile transcripts unable to code for proteins. Random sampling of cDNAs from two evolutionarily divergent Giardia strains indicates that approximately 20% of cDNAs in the libraries represent polyadenylated sterile transcripts. RNase protection analysis and northern blot hybridization of three sterile transcript loci demonstrated that both the sterile transcript and a complementary mRNA were made in each case, further categorizing these sterile transcripts as antisense transcripts. Investigation of the genomic loci for these same three sterile antisense transcripts showed typical transcription units for the sense transcripts, but still failed to reveal a usable open reading frame for the sterile antisense transcripts. 5'-RACE mapped the transcription start site for one of the sterile antisense transcripts to an AT-rich region, as is typical for GIARDIA: It is unclear whether these sterile transcripts represent errors in transcription or whether they have regulatory functions within the cell, although preliminary investigations failed to reveal evidence for a role in developmental gene regulation. In either case, the presence of such a large pool of sterile antisense transcripts is dramatic evidence of the unusual molecular machinery of the early diverging protist G.lamblia.

  16. DNA Prime/Adenovirus Boost Malaria Vaccine Encoding P. falciparum CSP and AMA1 Induces Sterile Protection Associated with Cell-Mediated Immunity

    DTIC Science & Technology

    2013-02-14

    Vaccination of monkeys with recombinant Plasmodium falciparum apical membrane antigen 1 confers protection against blood-stage malaria . Infect Immun...circumsporozoite protein partially protects healthy malaria -naive adults against Plasmodium falciparum sporozoite challenge. Infect Immun 74: 5933–5942...Ballou WR, et al. (1986) Malaria transmitted to humans by mosquitoes infected from cultured Plasmodium falciparum . Am J Trop Med Hyg 35: 66–68. 37

  17. Hysteroscopic Tubal Sterilization

    PubMed Central

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  18. Sterile Neutrinos in Cold Climates

    SciTech Connect

    Jones, Benjamin J.P.

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  19. Comprehensive Cross-Clade Characterization of Antibody-Mediated Recognition, Complement-Mediated Lysis, and Cell-Mediated Cytotoxicity of HIV-1 Envelope-Specific Antibodies toward Eradication of the HIV-1 Reservoir.

    PubMed

    Mujib, Shariq; Liu, Jun; Rahman, A K M Nur-Ur; Schwartz, Jordan A; Bonner, Phil; Yue, Feng Yun; Ostrowski, Mario A

    2017-08-15

    Immunotherapy with passive administration of broadly neutralizing HIV-1 envelope-specific antibodies (bnAbs) in the setting of established infection in vivo has yielded mixed results. The contribution of different antibodies toward the direct elimination of infected cells is poorly understood. In this study, we determined the ability of 12 well-characterized anti-HIV-1 neutralizing antibodies to recognize and eliminate primary CD4 T cells infected with HIV-1 belonging to clades A, B, C, and D, via antibody-dependent complement-mediated lysis (ADCML) and antibody-dependent cell-mediated cytotoxicity (ADCC), in vitro We further tested unique combinations of these antibodies to determine the optimal antibody cocktails to be tested in future clinical trials. We report that antibody binding to infected CD4 T cells is highly variable and correlates with ADCML and ADCC processes. Particularly, antibodies targeting the envelope glycan shield (2G12) and V1/V2 site (PG9, PG16, and PGT145) are best at recognizing HIV-1-infected CD4 T cells. However, only PG9 and PG16 and their combinations with other bnAbs sufficiently induced the elimination of HIV-1-infected CD4 T cells by ADCML, ADCC, or both. Notably, CD4 binding site antibodies VRC01, 3BNC117, and NIH45-46 G54W did not exhibit recognition of infected cells and were unable to induce their killing. Future trials geared toward the development of a cure for HIV/AIDS should incorporate V1/V2 antibodies for maximal clearance of infected cells. With the use of only primary immune cells, we conducted a comprehensive cross-clade physiological analysis to aid the direction of antibodies as therapeutics toward the development of a cure for HIV/AIDS.IMPORTANCE Several antibodies capable of neutralizing the majority of circulating HIV-1 strains have been identified to date and have been shown to prevent infection in animal models. However, the use of combinations of such broadly neutralizing antibodies (bnAbs) for the treatment and

  20. STERILIZED in the Name of Public Health

    PubMed Central

    Stern, Alexandra Minna

    2005-01-01

    In exploring the history of involuntary sterilization in California, I connect the approximately 20 000 operations performed on patients in state institutions between 1909 and 1979 to the federally funded procedures carried out at a Los Angeles County hospital in the early 1970s. Highlighting the confluence of factors that facilitated widespread sterilization abuse in the early 1970s, I trace prosterilization arguments predicated on the protection of public health. This historical overview raises important questions about the legacy of eugenics in contemporary California and relates the past to recent developments in health care delivery and genetic screening. PMID:15983269

  1. Sterile chamber operation with bio-isolator suit system

    NASA Technical Reports Server (NTRS)

    Hueschen, R. M.

    1972-01-01

    Development and characteristics of protective suit to permit man to operate in biologically sterile environment are described. Construction of tunnel, flexible seals, and cooling system are analyzed. Illustration of isolation suit is provided.

  2. Development of vapor phase hydrogen peroxide sterilization process for spacecraft applications

    NASA Technical Reports Server (NTRS)

    Rohatgi, N.; Schubert, W.; Knight, J.; Quigley, M.; Forsberg, G.; Ganapathi, G.; Yarbrough, C.; Koukol, R.

    2001-01-01

    This paper will present test data and discussion on the work we are conducting at JPL to address the following issues: 1) efficacy of sterilization process; 2) diffusion of hydrogen peroxide under sterilization process conditions into hard to reach places; 3) materials and components compatibility with the sterilization process and 4) development of methodology to protect sensitive components from hydrogen peroxide vapor.

  3. Development of vapor phase hydrogen peroxide sterilization process for spacecraft applications

    NASA Technical Reports Server (NTRS)

    Rohatgi, N.; Schubert, W.; Knight, J.; Quigley, M.; Forsberg, G.; Ganapathi, G.; Yarbrough, C.; Koukol, R.

    2001-01-01

    This paper will present test data and discussion on the work we are conducting at JPL to address the following issues: 1) efficacy of sterilization process; 2) diffusion of hydrogen peroxide under sterilization process conditions into hard to reach places; 3) materials and components compatibility with the sterilization process and 4) development of methodology to protect sensitive components from hydrogen peroxide vapor.

  4. The sterile inflammatory response.

    PubMed

    Rock, Kenneth L; Latz, Eicke; Ontiveros, Fernando; Kono, Hajime

    2010-01-01

    The acute inflammatory response is a double-edged sword. On the one hand, it plays a key role in initial host defense, particularly against many infections. On the other hand, its aim is imprecise, and as a consequence, when it is drawn into battle, it can cause collateral damage in tissues. In situations where the inciting stimulus is sterile, the cost-benefit ratio may be high; because of this, sterile inflammation underlies the pathogenesis of a number of diseases. Although there have been major advances in our understanding of how microbes trigger inflammation, much less has been learned about this process in sterile situations. This review focuses on a subset of the many sterile stimuli that can induce inflammation-specifically dead cells and a variety of irritant particles, including crystals, minerals, and protein aggregates. Although this subset of stimuli is structurally very diverse and might appear to be unrelated, there is accumulating evidence that the innate immune system may recognize them in similar ways and stimulate the sterile inflammatory response via common pathways. Here we review established and emerging data about these responses.

  5. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    PubMed

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  6. About the Sterilization of Chitosan Hydrogel Nanoparticles

    PubMed Central

    Galante, Raquel; Rediguieri, Carolina F.; Kikuchi, Irene Satiko; Vasquez, Pablo A. S.; Colaço, Rogério; Pinto, Terezinha J. A.

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles. PMID:28002493

  7. Karlson ozone sterilizer. Final report

    SciTech Connect

    Karlson, E.

    1984-05-07

    The authors have a functional sterilization system employing ozone as a sterilization agent. This final report covers the work that led to the first medical sterilizer using ozone as the sterilizing agent. The specifications and the final design were set by hospital operating room personnel and public safety standards. Work on kill tests using bacteria, viruses and fungi determined the necessary time and concentration of ozone necessary for sterilization. These data were used in the Karlson Ozone Sterilizer to determine the length of the steps of the operating cycle and the concentration of ozone to be used. 27 references.

  8. Sterilization by dry heat

    PubMed Central

    Darmady, E. M.; Hughes, K. E. A.; Jones, J. D.; Prince, D.; Tuke, Winifred

    1961-01-01

    The advantages and disadvantages of three forms of dry heat sterilization are discussed. In addition a fourth method, consisting of heating by infrared rays in vacuo, is described. This method is particularly suitable for instruments used in the operating theatre, since it can replace an autoclave where a supply of steam is not available. Recommended times and temperatures for dry heat sterilization are detailed, and are related to the thermal death point of Cl. tetani. The dangers of recontamination during the cooling process are discussed. PMID:13719782

  9. Heat sterilization of wood

    Treesearch

    Xiping Wang

    2010-01-01

    Two important questions should be considered in heat sterilizing solid wood materials: First, what temperature–time regime is required to kill a particular pest? Second, how much time is required to heat the center of any wood configuration to the kill temperature? The entomology research on the first question has facilitated the development of international standards...

  10. Sterilization of Native Americans

    ERIC Educational Resources Information Center

    Dillingham, Brint

    1977-01-01

    The U.S. State Department's Agency for International Development (AID) is spending more than $143 million this year for population control measures in over 70 nations around the world and it is estimated that as much as $10 million was spent in one year for surgical sterilization procedures. (JC)

  11. Radiation sterilization of ketoprofen

    NASA Astrophysics Data System (ADS)

    Katušin-Ražem, Branka; Hamitouche, Katia; Maltar-Strmečki, Nadica; Kos, Karmen; Pucić, Irina; Britvić-Budicin, Smiljana; Ražem, Dušan

    2005-06-01

    Radiation sterilization of ketoprofen (KP) dry powder was investigated by selected physico-chemical methods. High-performance liquid chromatography, ultraviolet spectrophotometry, infrared spectrophotometry, differential scanning calorimetry, X-ray diffraction and electron spin resonance spectroscopy did not show any significant degradation at sterilization dose 25 kGy. To determine the nature, extent and direction of radiation-induced changes, KP was irradiated to extremely high doses, much higher than necessary to achieve sterility. The irradiated KP did not show any difference of XRD patterns up to 200 kGy; with DSC and IR some changes were detected only above 1000 and 2000 kGy, respectively; HPLC has shown about 5% destruction at 2000 kGy. Acetyl benzophenon (AcBph) was generated by irradiation with G(AcBph)=(1.6±0.1)×10 -8 mol J -1. Ames test has shown no mutagenicity of KP irradiated with 3000 kGy or of the oily mixure of radiolytic products isolated from it. Solid KP has proven to be very stable on irradiation, and irradiation has been found to be a suitable method for its sterilization.

  12. MINOS Sterile Neutrino Search

    SciTech Connect

    Koskinen, David Jason

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  13. Sterilization surgery - making a decision

    MedlinePlus

    ... medlineplus.gov/ency/article/002138.htm Sterilization surgery - making a decision To use the sharing features on this page, ... about all the options available to you before making the decision to have a sterilization procedure. Alternative Names Deciding ...

  14. Sterilizing Immunity Elicited by Neisseria meningitidis Carriage Shows Broader Protection than Predicted by Serum Antibody Cross-Reactivity in CEACAM1-Humanized Mice

    PubMed Central

    McCaw, Shannon E.; Strobel, Lea; Frosch, Matthias

    2014-01-01

    Neisseria meningitidis asymptomatically colonizes the human upper respiratory tract but is also the cause of meningitis and severe septicemia. Carriage or disease evokes an immune response against the infecting strain. Hitherto, we have known little about the breadth of immunity induced by natural carriage of a single strain or its implications for subsequent infectious challenge. In this study, we establish that transgenic mice expressing human CEACAM1 support nasal colonization by a variety of strains of different capsular types. Next, we nasally challenged these mice with either of the N. meningitidis strains H44/76 (serogroup B, ST-32) and 90/18311 (serogroup C, ST-11), while following the induction of strain-specific immunoglobulin. When these antisera were tested for reactivity with a diverse panel of N. meningitidis strains, very low levels of antibody were detected against all meningococcal strains, yet a mutually exclusive “fingerprint” of high-level cross-reactivity toward certain strains became apparent. To test the efficacy of these responses for protection against subsequent challenge, CEACAM1-humanized mice exposed to strain 90/18311 were then rechallenged with different N. meningitidis strains. As expected, the mice were immune to challenge with the same strain and with a closely related ST-11 strain, 38VI, while H44/76 (ST-32) could still colonize these animals. Notably, however, despite the paucity of detectable humoral response against strain 196/87 (ST-32), this strain was unable to colonize the 90/18311-exposed mice. Combined, our data suggest that current approaches may underestimate the actual breadth of mucosal protection gained through natural exposure to N. meningitidis strains. PMID:25368118

  15. Sex and the Mentally Retarded: Is Sterilization the Answer?

    PubMed Central

    Christie, Ronald J.; McCracken, Eric C.

    1983-01-01

    The sexuality of the mentally handicapped concerns them, their parents, their family physicians and other health professionals. Parents need advice, and the well-informed family physician who has the family's trust is in a good position to give it. However, the physician must protect the rights and autonomy of the mentally handicapped patient concerning contraception, surgical sterilization and hysterectomy. Before recommending a method of contraception, the physician must identify any medical risks and be satisfied that the patient clearly understands risks and advantages. Sterilization as a method of contraception should never be considered unless the patient chooses it; involuntary sterilization can produce serious and significant psychological damage. The physician must give a detailed explanation to make sure the patient electing to be surgically sterilized understands the procedure and has fully consented without coercion. Hysterectomy should never be used as a method of sterilization. PMID:21283285

  16. Effectiveness of ethylene oxide for sterilization of dental handpieces.

    PubMed

    Parker, H H; Johnson, R B

    1995-04-01

    Ethylene oxide gas has been utilized as an alternative method for sterilization of dental handpieces, as it is less corrosive than steam. However, its effectiveness for sterilization of the internal components of dental handpieces has not been established. The objective of this study was to compare the effectiveness of ethylene oxide and steam for sterilization of dental handpieces. Unused handpieces and handpieces which had been exposed to clinical dental procedures ('clinical') were contaminated with Streptococcus mutans, exposed to steam or ethylene oxide, and flushed with sterile saline. Washings were plated on mitis-salivarius agar, and colonies identified and counted. No viable colonies could be established from washings from 'clinical' or 'unused' handpieces exposed to steam. However, viable colonies could be established from 'clinical' handpieces exposed to ethylene oxide. This data suggests that a substance entrapped within 'clinical' handpieces (possibly the biofilm) may protect bacteria from ethylene oxide gas, preventing adequate sterilization.

  17. Vapor Hydrogen Peroxide Sterilization Certification

    NASA Astrophysics Data System (ADS)

    Chen, Fei; Chung, Shirley; Barengoltz, Jack

    For interplanetary missions landing on a planet of potential biological interest, United States NASA planetary protection currently requires that the flight system must be assembled, tested and ultimately launched with the intent of minimizing the bioload taken to and deposited on the planet. Currently the only NASA approved microbial reduction method is dry heat sterilization process. However, with utilization of such elements as highly sophisticated electronics and sensors in modern spacecraft, this process presents significant materials challenges and is thus an undesirable bioburden reduction method to design engineers. The objective of this work is to introduce vapor hydrogen peroxide (VHP) as an alternative to dry heat microbial reduction to meet planetary protection requirements. The VHP sterilization technology is widely used by the medical industry, but high doses of VHP may degrade the performance of flight hardware, or compromise material compatibility. The goal of our study is determine the minimum VHP process conditions for PP acceptable microbial reduction levels. A series of experiments were conducted using Geobacillus stearothermophilus to determine VHP process parameters that provided significant reductions in spore viability while allowing survival of sufficient spores for statistically significant enumeration. In addition to the obvious process parameters -hydrogen peroxide concentration, number of pulses, and exposure duration -the investigation also considered the possible effect of environmental pa-rameters. Temperature, relative humidity, and material substrate effects on lethality were also studied. Based on the results, a most conservative D value was recommended. This recom-mended D value was also validated using VHP "hardy" strains that were isolated from clean-rooms and environmental populations collected from spacecraft relevant areas. The efficiency of VHP at ambient condition as well as VHP material compatibility will also be

  18. STAT3, a Key Parameter of Cytokine-Driven Tissue Protection during Sterile Inflammation – the Case of Experimental Acetaminophen (Paracetamol)-Induced Liver Damage

    PubMed Central

    Mühl, Heiko

    2016-01-01

    Acetaminophen (APAP, N-acetyl-p-aminophenol, or paracetamol) overdosing is a prevalent cause of acute liver injury. While clinical disease is initiated by overt parenchymal hepatocyte necrosis in response to the analgetic, course of intoxication is substantially influenced by associated activation of innate immunity. This process is supposed to be set in motion by release of danger-associated molecular patterns (DAMPs) from dying hepatocytes and is accompanied by an inflammatory cytokine response. Murine models of APAP-induced liver injury emphasize the complex role that DAMPs and cytokines play in promoting either hepatic pathogenesis or resolution and recovery from intoxication. Whereas the function of key inflammatory cytokines is controversially discussed, a subclass of specific cytokines capable of efficiently activating the hepatocyte signal transducer and activator of transcription (STAT)-3 pathway stands out as being consistently protective in murine models of APAP intoxication. Those include foremost interleukin (IL)-6, IL-11, IL-13, and IL-22. Above all, activation of STAT3 under the influence of these cytokines has the capability to drive hepatocyte compensatory proliferation, a key principle of the regenerating liver. Herein, the role of these specific cytokines during experimental APAP-induced liver injury is highlighted and discussed in a broader perspective. In hard-to-treat or at-risk patients, standard therapy may fail and APAP intoxication can proceed toward a fatal condition. Focused administration of recombinant STAT3-activating cytokines may evolve as novel therapeutic approach under those ill-fated conditions. PMID:27199988

  19. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  20. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  1. Sterilization of Medical Instruments

    DTIC Science & Technology

    2007-05-06

    possible use with medical instruments and skin catheters. To address this challenge, MicroStructure Technologies (MicroST) is developing an...Project: DARPA - Sterilization of Medical Instruments Contract: # FA9550-06-C-0054 Principal Investigator: Joseph Birmingham Report: FINAL Report 1...as medical instruments and skin catheters. To address this challenge, MicroStructure Technologies (MicroST) is proposing a compact, low maintenance

  2. Sterilization by oxygen plasma

    NASA Astrophysics Data System (ADS)

    Moreira, Adir José; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Zambon, Luis da Silva; da Silva, Mônica Valero; Verdonck, Patrick Bernard

    2004-07-01

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  3. Hysteroscopic Tubal Sterilization

    PubMed Central

    2013-01-01

    Background Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. Objectives The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. Data Sources A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Review Methods Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. Results A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. Limitations All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Conclusions Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Plain Language Summary Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal

  4. [Studies on the method of sterilization with ethylene oxide gas. 1. Sterilization procedure and sterilizing effect].

    PubMed

    Arimoto, H; Ukisu, S; Yamada, Y; Sano, K; Kanri, T

    1989-12-01

    Undertaken to ensure perfection of sterilization with ethylene oxide gas (EO gas) in routine clinical laboratory practice, an investigation was made of the relationship between sterilization procedure and sterilizing effect using the film bag delivery system and chamber system. Using a biological indicator as a monitor of sterilizing effect, the efficiency of sterilization was studied under various likely conditions and compared. The results led to the following conclusions: 1. Sterilization with EO gas by the film bag delivery system, because of this procedure being unable to be performed at a constant temperature, was shown to prove inadequate due to insufficient exposure to gas especially in winter season (when room temperature fell below 10 degrees C). 2. With the EO gas sterilization method using the film bag delivery system, which is believed to be effective within the ordinary range of humidity of the atmosphere, sterilizing effect was recognized to be affected by excess wetting of an object of sterilization that was caused by inadvertent manipulation or due to a predisposing attribute of the object, such as shape or outline. 3. All materials are sterilized upon being packaged. It is necessary therefore to make best choice of package material with respect of texture and size. Reuse influence to sterilizing effect. 4. The method of sterilization with EO gas using the chamber system has the advantage in that operating conditions are all automatically controlled. For this reason, there was not a single instance of failure to sterilize due to inappropriateness of temperature and humidity. From these results it is concluded that sterilising effect was affected by sterilization procedure and condition.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. An international overview of sterilization.

    PubMed

    Dourlen-Rollier, A M

    1977-05-01

    Sterilization, both male and female, for family planning purposes developed very rapidly, beginning in Puerto Rico and Japan between 1940 and 1950 and continuing in India and Pakistan on a large scale after the mid-1950s. The legal status of voluntary sterilization around the world is confused, but recent developments show a trend toward liberalization of the laws. Certain countries still consider sterilization punishable under the criminal law, but there is a gap between the law and the practice. Certain countries have made the issue of consent relevant under the law. Certain other governments are studying the question of sterilization officially. Countries with heavy population pressures are employing incentives to encourage sterilization and others, specifically European countries, have legally authorized sterilization. The procedure is becoming increasingly accepted.

  6. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  7. Sterile neutrinos: fact or fiction?

    NASA Astrophysics Data System (ADS)

    Huber, Patrick

    2017-01-01

    In this talk I will critically review some of the anomalies which in combination could point to the existence of a eV-scale sterile neutrino. Each of these anomalies is well below the 5 sigma level individually and may have explanations besides sterile neutrinos. At the same time each anomaly requires a separate explanation if it is not caused by a sterile neutrino. To further complicate the gpicture, some data sets are in mutual disagreement.

  8. Post-tubal sterilization syndrome.

    PubMed

    Lethbridge, D J

    1992-01-01

    This article presents a review of the literature on post-tubal sterilization syndrome. Although studies have shortcomings they suggest the majority of women undergoing tubal sterilization do not experience changes in menstrual patterns after the procedure, but a minority do. Suggestions are made for further research, conducted from a nursing perspective. Implications for practice are suggested, given the tentative information on post-tubal sterilization syndrome.

  9. New disinfection and sterilization methods.

    PubMed Central

    Rutala, W. A.; Weber, D. J.

    2001-01-01

    New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50). PMID:11294738

  10. A Sterile Robotic Mars Soil Analyzer

    NASA Technical Reports Server (NTRS)

    Levin, Gilbert V.; Miller, Joseph D.; Straat, Patricia Ann; Hoover, Richard E.

    2002-01-01

    Since the 1976 Viking Mission to Mars, follow-on efforts to resolve its controversial life detection results have been thwarted by two heretofore insurmountable difficulties: the huge expense of sterilizing the entire spacecraft to protect the integrity of life detection experiments; and the lack of a practical robotic life detection package that could produce results acceptable as unambiguous by the scientific community. We here present a method that assures sterility and the complete integrity of robotic life detection experiments, all at a negligible cost. Second, we propose a candidate set of integrated, highly sensitive experiments that we believe could produce results acceptable to the vast majority of scientists. In addition to the biology-chemistry issue, the extensively debated oxidative state of the Martian surface and other chemical and physical characteristics of the Martian soil would be determined. We present our concept for a miniaturized instrument that could carry out a number of candidate experiments to achieve the objective.

  11. IL-1 family cytokines trigger sterile inflammatory disease

    PubMed Central

    Lukens, John R.; Gross, Jordan M.; Kanneganti, Thirumala-Devi

    2012-01-01

    Inflammation plays vital roles in protective responses against pathogens and tissue repair, however, improper resolution of inflammatory networks is centrally involved in the pathogenesis of many acute and chronic diseases. Extensive advances have been made in recent years to define the inflammatory processes that are required for pathogen clearance, however, in comparison, less is known about the regulation of inflammation in sterile settings. Over the past decade non-communicable chronic diseases that are potentiated by sterile inflammation have replaced infectious diseases as the major threat to global human health. Thus, improved understanding of the sterile inflammatory process has emerged as one of the most important areas of biomedical investigation during our time. In this review we highlight the central role that interleukin-1 family cytokines play in sterile inflammatory diseases. PMID:23087690

  12. Sterilization of Extracted Human Teeth.

    ERIC Educational Resources Information Center

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  13. Sterilization of Extracted Human Teeth.

    ERIC Educational Resources Information Center

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  14. Ethylene oxide sterilization: how hospitals can adapt to the changes.

    PubMed

    1994-12-01

    Ethylene oxide (EtO) gas sterilizers have been used by hospitals for over 40 years to sterilize surgical equipment and supplies that are heat sensitive or that cannot tolerate excessive moisture. However, in recent decades, EtO has been recognized as a potential mutagenic, reproductive, neurologic, and fire and explosion hazard to workers, and one agency has reportedly voted to classify EtO as carcinogenic to humans. Strict regulations concerning EtO exposure have been imposed by the Occupational Safety and Health Administration (OSHA), and the use of EtO, along with other toxic pollutants, is also being monitored by the Environmental Protection Agency (EPA) under the Clean Air Act. In addition, the use of chlorofluorocarbons (CFCs) as EtO diluents has focused attention on the EtO-CFC mixtures used in many sterilizers because CFCs have been linked to destruction of the ozone layer. Concerns about restrictive regulations related to these issues have prompted many hospitals to examine their use of EtO sterilization and propagated the misinformation that EtO sterilization is being phased out. In this article, we address some commonly asked questions regarding the use and regulation of EtO mixtures, as well as alternative sterilization agents and methods; provide two case studies illustrating how hospitals can evaluate various sterilization options; and summarize our conclusions and recommendations for hospitals facing decisions about sterilization techniques. For related topics, also see our Evaluation Update on endoscope reprocessors and our Hazard Report on improperly connected EtO-CFC cylinders to EtO sterilizers in this issue.

  15. Ethylene Oxide Gaseous Sterilization

    PubMed Central

    Ernst, Robert R.; Shull, James J.

    1962-01-01

    The duration of the equilibration period between admission of water vapor and subsequent introduction of gaseous ethylene oxide to an evacuated sterilizer chamber was studied with respect to its effect on the inactivation of spores of Bacillus subtilis var. niger under simulated practical conditions. Introduction of a water-adsorbing cotton barrier between the spores and an incoming gas mixture of water vapor and ethylene oxide caused a marked increase in the observed thermochemical death time of the spore populations. This effect was negated by admission of water vapor one or more minutes prior to introduction of ethylene oxide gas. Increases in temperature and relative humidity of the system promoted passage of water vapor through the cotton barriers and diminished their effect. PMID:13890660

  16. Sterile Inflammation in Drosophila

    PubMed Central

    Shaukat, Zeeshan; Liu, Dawei; Gregory, Stephen

    2015-01-01

    The study of immune responses in Drosophila has already yielded significant results with impacts on our understanding of vertebrate immunity, such as the characterization of the Toll receptor. Several recent papers have focused on the humoral response to damage signals rather than pathogens, particularly damage signals from tumour-like tissues generated by loss of cell polarity or chromosomal instability. Both the triggers that generate this sterile inflammation and the systemic and local effects of it are only just beginning to be characterized in Drosophila. Here we review the molecular mechanisms that are known that give rise to the recruitment of Drosophila phagocytes, called hemocytes, as well as the signals, such as TNFα, that stimulated hemocytes emit at sites of perceived damage. The signalling consequences of inflammation, such as the activation of JNK, and the potential for modifying this response are also discussed. PMID:25948885

  17. Conditional sterility in plants

    DOEpatents

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  18. Steam sterilization of laparoscopic instruments.

    PubMed

    Voyles, C R; Sanders, D L; Simons, J E; McVey, E A; Wilson, W B

    1995-04-01

    Because of the intricate internal parts of laparoscopic instruments, questions have been raised about the efficacy of cleaning and sterilization techniques. To assess these risks, hamburger meat was inoculated with high concentrations of vegetative pathogens and packed into laparoscopic cannulas. All openings of the cannulas were sealed during steam sterilization cycles ranging from 3 to 10 min in different experiments; cultures were obtained after cooling. Experiments were then performed using heat-resistant spore forms. Our studies showed that both the standard 10-min cycle and the 3-min "flash" were uniformly successful in killing all pathogenic microorganisms. A 7-min steam sterilization was necessary to kill spores within sealed cannulas. We conclude that a standard 10-min cycle within the steam autoclave provides complete sterilization of laparoscopic instruments; the 3-min "flash" sterilization is appropriate and safe for instruments that have been inadvertently contaminated or dropped during a surgical procedure.

  19. Electrolytic silver ion cell sterilizes water supply

    NASA Technical Reports Server (NTRS)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  20. Pain Associated With Hysteroscopic Sterilization

    PubMed Central

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  1. A novel H6N1 virus-like particle vaccine induces long-lasting cross-clade antibody immunity against human and avian H6N1 viruses.

    PubMed

    Yang, Ji-Rong; Chen, Chih-Yuan; Kuo, Chuan-Yi; Cheng, Chieh-Yu; Lee, Min-Shiuh; Cheng, Ming-Chu; Yang, Yu-Chih; Wu, Chia-Ying; Wu, Ho-Sheng; Liu, Ming-Tsan; Hsiao, Pei-Wen

    2016-02-01

    Avian influenza A(H6N1) virus is one of the most common viruses isolated from migrating birds and domestic poultry in many countries. The first and only known case of human infection by H6N1 virus in the world was reported in Taiwan in 2013. This led to concern that H6N1 virus may cause a threat to public health. In this study, we engineered a recombinant H6N1 virus-like particle (VLP) and investigated its vaccine effectiveness compared to the traditional egg-based whole inactivated virus (WIV) vaccine. The H6N1-VLPs exhibited similar morphology and functional characteristics to influenza viruses. Prime-boost intramuscular immunization in mice with unadjuvanted H6N1-VLPs were highly immunogenic and induced long-lasting antibody immunity. The functional activity of the VLP-elicited IgG antibodies was proved by in vitro seroprotective hemagglutination inhibition and microneutralization titers against the homologous human H6N1 virus, as well as in vivo viral challenge analyses which showed H6N1-VLP immunization significantly reduced viral load in the lung, and protected against human H6N1 virus infection. Of particular note, the H6N1-VLPs but not the H6N1-WIVs were able to confer cross-reactive humoral immunity; antibodies induced by H6N1-VLP vaccine robustly inhibited the hemagglutination activities and in vitro replication of distantly-related heterologous avian H6N1 viruses. Furthermore, the H6N1-VLPs were found to elicit significantly greater anti-HA2 antibody responses in immunized mice than H6N1-WIVs. Collectively, we demonstrated for the first time a novel H6N1-VLP vaccine that effectively provides broadly protective immunity against both human and avian H6N1 viruses. These results, which uncover the underlying mechanisms for induction of wide-range immunity against influenza viruses, may be useful for future influenza vaccine development. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Portable Decontamination and Sterilization System

    DTIC Science & Technology

    2004-11-17

    No external power required • Gas-phase sterilant generated by chemical reaction • Sterilant is chlorine dioxide, ClO2 • Rapid, proven effective in...earlier studies • Solutions of ClO2 in water are effective against VX and HD on surfaces; no data for gaseous ClO2 with CW agents • ClO2 is effective...ingredients • Sterilizer bag design (single use) • Indicators • Vent with ClO2 scavenger • Overwrap TDA R e s e a r c h Generation of ClO2 • Widely

  3. Sterile Keratitis following Collagen Crosslinking.

    PubMed

    Javadi, Mohammad-Ali; Feizi, Sepehr

    2014-01-01

    To report a keratoconic eye that developed severe sterile keratitis and corneal scar after collagen crosslinking necessitating corneal transplantation. A 26-year-old man with progressive keratoconus underwent collagen crosslinking and presented with severe keratitis 72 hours after the procedure. The initial impression was infectious corneal ulcer and a fortified antibiotic regimen was administered. However, the clinical course and confocal microscopy results prompted a diagnosis of sterile keratitis. The eye developed severe corneal scars leading to reduced visual acuity and necessitating corneal transplantation. Sterile keratitis may develop after collagen crosslinking resulting in profound visual loss leading to corneal transplantation.

  4. Food irradiation and sterilization

    NASA Astrophysics Data System (ADS)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  5. Planned condom use among women undergoing tubal sterilization.

    PubMed

    Sangi-Haghpeykar, H; Poindexter, A N

    1998-08-01

    Women undergoing tubal sterilization are at risk of various sexually transmitted diseases (STDs) if they do not use a barrier method of contraception. The authors investigated the planned use of condoms for protection against STDs among 2782 women undergoing surgical sterilization during 1991-96 at the Baylor College of Medicine in Houston, Texas. The women were 18-50 years old (mean age, 30.3 years); 62% were Hispanic, 20% Black, and 17% White. 31% reported being unmarried, the mean level of educational attainment was 9.8 years, and 20% had a known risk factor for HIV. 646 of the women reported regular condom use during the 3 months before being sterilized, of whom 45% had no plans to continue their practice after becoming sterilized. 11% of the total sample therefore planned to stop using condoms once sterilized. Among Hispanic, White, and Black women, respectively, 55%, 36%, and 18% planned to stop condom use once sterilized. Also, among former condom users, 54% of married women and 21% of unmarried women planned to abandon condom use. Factors found through multiple regression analysis to be associated with future condom use were younger age, being Black, unmarried status, having previously had a STD, not having a steady sex partner, having a relatively higher number of previous sex partners, having ever used condoms to prevent disease, and lack of partner involvement in the decision to be sterilized. The planned future use of condoms among women undergoing sterilization increased steadily and significantly from 1991 to 1996, irrespective of age, marital status, or ethnic background.

  6. Synergistic Effects in Sonochemical Sterilization

    PubMed Central

    Boucher, Raymond M. G.; Pisano, Michael A.; Tortora, George; Sawicki, Edward

    1967-01-01

    The synergistic effects observed during the sterilization of Bacillus subtilis var. niger ATCC 9372 by the combined action of ethylene or propylene oxide with high-intensity airborne sound waves (34.8 kc/sec) were investigated. It has been shown that the number of surviving spores deposited on paper strips decreases exponentially with the sound intensity at sample level. Reductions of the order of one-third of the time required for standard propylene oxide sterilization have been observed by using the combined action of sound waves with gaseous sterilization. At the present time, maximal synergistic effects seem to be achieved for the following experimental conditions: propylene oxide concentration, 500 to 1,000 mg/liter; acoustic intensity, 161 to 162 db; contact time, 80 min; temperature, 60 C; and relative humidity, 40%. The basic mechanism involved in sonochemical sterilization seems to be more of a physical (accelerated gas diffusion) than a chemical nature. PMID:4965941

  7. Sterilization 1. The changing attitude.

    PubMed

    Teper, S

    1977-01-01

    Since the end of World War 2 in the U.S., there has been a marked change in attitude towards and treatment of the mentally handicapped, and the result - in terms of sterilization - is that many States no longer use their compulsory sterilization laws and some have repealed them. In any event, the incidence of compulsory sterilization has decreased markedly. Yet, in the past decade there have been occasional attempts to resort to the procedure for punitive reasons. These efforts have generally involved women with illegitimate children who are supported by welfare payments. Over the same decade there has been in the U.S. a remarkable growth in the use of voluntary and contraceptive sterilization as the means of preventing additional children. Preliminary results from the national Survey of Family Growth 1973 revealed that 29% of couples between the ages of 15 and 44 years who did not want more children were sterilized - males and females about equally. In Britain the development of sterilization has followed a somewhat different path. During the 1st decades of the 20th century the people in Britain were very concerned about the extensiveness of mental subnormality in the population and with the care of this group. In 1930 the Eugenics society made its 1st formal statement on the use of sterilization, advocating its use for those individuals who might transmit severe physical or mental defects which might affect the health of their progeny. More evidence was determined needed before there would be an attempt made to initiate legislation, and no legislation was ever effected. Also, from 1925 onwards, there was a debate in medical and legal circles on the consequences for patients and doctors of sterilizing operations and on the risks of litigation in the criminal and civil courts. The most marked change came in 1972 when the National Health Service (Family Planning) Act empowered local authorities to provide facilities for vasectomy on the same basis as other

  8. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  9. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  10. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  11. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  12. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  13. Radiation sterilization of skin allograft

    NASA Astrophysics Data System (ADS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  14. Costs of low-temperature plasma sterilization compared with other sterilization methods.

    PubMed

    Adler, S; Scherrer, M; Daschner, F D

    1998-10-01

    Plasma sterilization is a new technique for decontaminating thermolabile products without the severe drawbacks associated with gas sterilization methods (residues, environment compatibility). The actual costs, per sterilization unit, of three sterilization techniques--plasma, ethylene oxide and formaldehyde--were compared. As plasma sterilization is an alternative to steam sterilization for sterilizing thermostable but easily corroding products or electronic instruments, costs for steam sterilization were calculated and compared as well. If one considers only the cost of the sterilization procedure itself, without taking into account the time-saving element of plasma sterilization, then ethylene oxide sterilization proves to be the most expensive procedure, followed by plasma sterilization; sterilization with formaldehyde was the least expensive. Inclusion of the time required to sterilize an instruments, however, altered the relative costs of the three methods. Because plasma sterilization takes less time to perform than either ethylene oxide or formaldehyde sterilization, fewer instruments need be procured. In order to measure and compare the time-saving advantage that plasma sterilization affords, five groups of instruments were assembled and the total cost of sterilizing an instrument of each group was calculated. The five groups included (1) disposable, (2) electronic, (3) endoscopic, (4) sharp and (5) standard instruments. In all cases, ethylene oxide sterilization was the most expensive method. Formaldehyde sterilization was, in four out of five cases, more expensive than plasma sterilization. Steam sterilization proved to be the cheapest method of sterilizing a laparoscopic set, even when costs due to damage inflicted on the optical instruments were calculated. In the case of a vitrectome, however, plasma sterilization costs were nearly the same as steam sterilization when the lower rate of damage by plasma sterilization was taken into account.

  15. Genomic Networks of Hybrid Sterility

    PubMed Central

    Turner, Leslie M.; White, Michael A.; Tautz, Diethard; Payseur, Bret A.

    2014-01-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci (“Dobzhansky-Muller incompatibilities”). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven ‘hotspots,’ seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL—but not cis eQTL—were substantially lower when mapping was restricted to a ‘fertile’ subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  16. The limits of sterility assurance.

    PubMed

    von Woedtke, Thomas; Kramer, Axel

    2008-09-03

    Sterility means the absence of all viable microorganisms including viruses. At present, a sterility assurance level (SAL) of 10(-6) is generally accepted for pharmacopoeial sterilization procedures, i.e., a probability of not more than one viable microorganism in an amount of one million sterilised items of the final product. By extrapolating the reduction rates following extreme artificial initial contamination, a theoretical overall performance of the procedure of at least 12 lg increments (overkill conditions) is demanded to verify an SAL of 10(-6). By comparison, other recommendations for thermal sterilization procedures demand only evidence that the difference between the initial contamination and the number of test organisms at the end of the process amount to more than six orders of magnitude. However, a practical proof of the required level of sterility assurance of 10(-6) is not possible. Moreover, the attainability of this condition is fundamentally dubious, at least in non-thermal procedures. Thus, the question is discussed whether the undifferentiated adherence to the concept of sterility assurance on the basis of a single SAL of 10(-6) corresponds with the safety requirements in terms of patient or user safety, costs and energy efficiency. Therefore, in terms of practical considerations, a concept of tiered SALs is recommended, analogous to the comparable and well-established categorization into "High-level disinfection", "Intermediate-level disinfection" and "Low-level disinfection". The determination of such tiered SALs is geared both to the intended application of the sterilized goods, as well as to the characteristics of the products and the corresponding treatment options.In the case of aseptic preparation, filling and production procedures, a mean contamination probability of 10(-3) is assumed. In automated processes, lower contamination rates can be realized. In the case of the production of re-usable medical devices, a reduction of at least 2

  17. Bacterial Sterilization Using Cavitating Jet

    NASA Astrophysics Data System (ADS)

    Azuma, Yohei; Kato, Hiroharu; Usami, Ron; Fukushima, Tadamasa

    In this paper, a new sterilization method using cavitating flow is presented. Water with bacteria was pressurized up to 105 MPa and flushed out through two very small nozzles 0.1-0.31 mm in diameter, where a cavitating jet was generated containing bubbles that collapsed downstream. First, the effects of jet velocity and cavitation number on the sterilization rate of Escherichia coli JCM1649T (E. coli) were examined. The sterilization rate increased with jet velocity. The rate was proportional to the 3rd power of the velocity. All the E. coli cells were killed by three successive treatments at V=355.7 m/s and cavitation number σ=0.154. The sterilization rate has a peak depending on cavitation number at the low-jet-velocity region of less than 300 m/s. An experiment was also performed to compare two types of bacteria, E. coli, as typical Gram-negative bacteria and Bacillus subtilis JCM1465T (B. subtilis), as typical Gram-positive bacteria. Additional tests were performed using Pseudomonas putida JCM13063T, Gram-negative bacteria and Bacillus halodurans JCTM9153, Gram-positive bacteria. The sterilization rate of the Gram-positive bacteria was much lower than that of the Gram-negative bacteria under the same experimental conditions. Gram-positive bacteria have a thicker peptidoglycan layer than Gram-negative bacteria. This may be the reason why B. subtilis is more resistant to the mechanical stress caused by cavitating flow.

  18. Are all sterilization processes alike?

    PubMed

    Muscarella, L F

    1998-05-01

    Automated processes designed to sterilize reusable medical instruments use heat and low-temperature chemicals. Several factors, including the physical properties of the sterilizing agents and whether all of the instruments' surfaces can be adequately cleaned, can cause significant variations in the reliability and effectiveness of the sterilization processes. Instruments exposed to heat-based sterilization processes pose the lowest probability of transmitting diseases between patients. Heat can conduct through many different types of materials and can destroy microorganisms embedded under layers of patient debris. Studies have demonstrated, however, that--unlike heat--low-temperature chemicals require direct contact with the microorganisms to be effective. Moreover, the complex designs of some instruments can adversely affect the low-temperature sterilization processes' outcomes by hindering cleaning and preventing the flow of low-temperature chemicals to all of the instruments' contaminated surfaces. This article will explore the differences between heat-based and low-temperature chemical processes to help health care providers minimize the risk of cross-infection.

  19. Sterile versus non-sterile glove use and aseptic technique.

    PubMed

    Flores, Ashley

    There is evidence indicating that improvements in infection control practice can reduce the incidence of healthcare-associated infection. This article explores the evidence base for glove use and aseptic technique. There is a lack of evidence regarding the influence of sterile versus clean gloves in clinical care. Therefore in practice, clean and aseptic techniques are often used interchangeably. Nurses must learn to select clean or aseptic technique, and therefore clean or sterile gloves, using a risk assessment protocol. Regular audits of aseptic technique and education are needed to improve care.

  20. Antioxidant properties of sterilized yacon (Smallanthus sonchifolius) tuber flour.

    PubMed

    Sousa, Sérgio; Pinto, Jorge; Rodrigues, César; Gião, Maria; Pereira, Claúdia; Tavaria, Freni; Malcata, F Xavier; Gomes, Ana; Bertoldo Pacheco, M T; Pintado, Manuela

    2015-12-01

    The objective of this research work was to investigate the antioxidant properties of sterilized yacon tuber flour. The results revealed for the first time the high antioxidant activity of sterilized yacon flour. The best extract obtained by boiling 8.9% (w/v) of yacon flour in deionised water for 10 min exhibited a total antioxidant capacity of 222±2 mg (ascorbic acid equivalent)/100 g DW and a total polyphenol content of 275±3 mg (gallic acid equivalent)/100 g DW associated to the presence of four main phenolic compounds: chlorogenic acid, caffeic acid, coumaric acid and protocatechuic acid, as well as the amino acid tryptophan. The most abundant was chlorogenic acid, followed by caffeic acid. Biological assays revealed that the extract had indeed antioxidant protection, and no pro-oxidant activity. In conclusion, sterilized yacon tuber flour has the potential to be used in the food industry as a food ingredient to produce functional food products.

  1. Cytoplasmic Sterility Factors in VICIA FABA L

    PubMed Central

    Edwardson, J. R.; Bond, D. A.; Christie, R. G.

    1976-01-01

    Tissues of cytoplasmic male sterile, maintainer, restorer, and restored lines, and sterile plants which reverted to fertility in Vicia faba were examined in ultrathin sections. Cytoplasmic spherical bodies (CSB), ca. 70 nm in diameter, were observed in tissues of all sterile plants but not in tissues of maintainer, restorer or restored sterile plants. No CSB were observed in a reverted fertile branch of a tiller-sterile plant, nor in 5 of 6 reverted fertile plants. One reverted fertile plant contained CSB in ovules. It is proposed that the CSB are the sites of, or possibly, products of, sterility factors in Vicia faba. PMID:17248701

  2. Portable Ethylene Oxide Sterilization Chamber

    PubMed Central

    Songer, J. R.; Mathis, R. G.

    1969-01-01

    A portable ethylene oxide sterilization chamber was designed, constructed, and tested for use in the sterilization of embolectomy catheters. The unit can accommodate catheters up to 40 inches (101.6 cm) in length and can be operated for less than 4 cents per cycle. A constant concentration of 500 mg of ethylene oxide per liter of space and holding periods of 4 and 6 hr at 43 and 22 C, respectively, were adequate when tested with B. subtilis spores. The estimated cost of construction was $165.00. If temperature control is unnecessary, the cost is approximately $80.00. Images PMID:4977644

  3. Transgenic technologies to induce sterility.

    PubMed

    Catteruccia, Flaminia; Crisanti, Andrea; Wimmer, Ernst A

    2009-11-16

    The last few years have witnessed a considerable expansion in the number of tools available to perform molecular and genetic studies on the genome of Anopheles mosquitoes, the vectors of human malaria. As a consequence, knowledge of aspects of the biology of mosquitoes, such as immunity, reproduction and behaviour, that are relevant to their ability to transmit disease is rapidly increasing, and could be translated into concrete benefits for malaria control strategies. Amongst the most important scientific advances, the development of transgenic technologies for Anopheles mosquitoes provides a crucial opportunity to improve current vector control measures or design novel ones. In particular, the use of genetic modification of the mosquito genome could provide for a more effective deployment of the sterile insect technique (SIT) against vector populations in the field. Currently, SIT relies on the release of radiation sterilized males, which compete with wild males for mating with wild females. The induction of sterility in males through the genetic manipulation of the mosquito genome, already achieved in a number of other insect species, could eliminate the need for radiation and increase the efficiency of SIT-based strategies. This paper provides an overview of the mechanisms already in use for inducing sterility by transgenesis in Drosophila and other insects, and speculates on possible ways to apply similar approaches to Anopheles mosquitoes.

  4. Sterile Neutrino Search with MINOS

    SciTech Connect

    Devan, Alena V.

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  5. Radappertization (Radiation Sterilization) of Foods

    DTIC Science & Technology

    1976-12-01

    Street, Westport, c·r 06880; 1974. S-78-P EVALUATION OF THE TINPLATE CONTAINER FOR PACKAGING OF IRRADIA- TION STERILIZED FOODS. J. J. Killoran, E... TINPLATE CAN FOR PACKAGING OF RADAPPERTIZED BEEF UNDER PRODUCTION CONDITIONS. J. J. Killoran, J. J. Hawker, and E. Wierbicki. 5-12𔄂-P RELIABILITY OF

  6. Firebreak Maintenance With Soil Sterilants

    Treesearch

    James K. Brown

    1966-01-01

    In 1959 and 1962 the Minnesota Division of Forestry and the North Central Forest Experiment Station established a series of tests to determine the effectiveness of several herbicides in maintaining firebreaks free of vegetation. The primary objectives of these tests were to determine: (1) how long one application of soil sterilant can keep firebreaks satisfactorily...

  7. Microwave powered sterile access port

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Atwater, James E. (Inventor); Dahl, Roger W. (Inventor); Garmon, Frank C. (Inventor); Lunsford, Teddie D. (Inventor); Michalek, William F. (Inventor); Wheeler, Jr., Richard R. (Inventor)

    2000-01-01

    A device and method for elimination of contamination during transfer of materials either into or from bioreactors, food containers, or other microbially vulnerable systems. Using microwave power, thermal sterilizations of mating fixtures are achieved simply, reliably, and quickly by the volatilization of small quantities of water to produce superheated steam which contacts all exposed surfaces.

  8. Sterile pyuria: a forgotten entity

    PubMed Central

    Persad, Raj

    2015-01-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results. PMID:26425144

  9. Sterilization of Persons with Mental Retardation.

    ERIC Educational Resources Information Center

    Elkins, Thomas E.; Andersen, H. Frank

    1992-01-01

    This article examines the historical, legal, and ethical concerns regarding sterilization for persons with mental retardation and offers guidelines to help counsel individuals with disabilities or their families regarding decision making about sterilization. (DB)

  10. Sterilization beneath rings on dental instruments.

    PubMed

    Miller, C H; Sheldrake, M A

    1991-12-01

    This study determined the effectiveness of standard methods of instrument sterilization beneath instrument rings. Sets of three types of dental instruments were contaminated with known amounts of bacterial spores (Bacillus stearothermophilus or Bacillus subtilis). Instrument rings were placed over the contamination and the instruments processed through standard cycles in a steam autoclave, an unsaturated chemical vapor sterilizer, a standard dry heat sterilizer, an ethylene oxide gas sterilizer or a 2.0% alkaline glutaraldehyde solution. Controls consisted of spore-contaminated instruments without rings that were not processed through any sterilizing method and that were processed through each sterilizing method. All instruments and their associated rings were cultured for the presence of live spores. The results indicate that the reliability of sterilization beneath the instrument rings used is greatest if the ringed instruments are processed through a steam autoclave or an unsaturated chemical vapor sterilizer.

  11. The limits of sterility assurance

    PubMed Central

    von Woedtke, Thomas; Kramer, Axel

    2008-01-01

    Sterility means the absence of all viable microorganisms including viruses. At present, a sterility assurance level (SAL) of 10–6 is generally accepted for pharmacopoeial sterilization procedures, i.e., a probability of not more than one viable microorganism in an amount of one million sterilised items of the final product. By extrapolating the reduction rates following extreme artificial initial contamination, a theoretical overall performance of the procedure of at least 12 lg increments (overkill conditions) is demanded to verify an SAL of 10–6. By comparison, other recommendations for thermal sterilization procedures demand only evidence that the difference between the initial contamination and the number of test organisms at the end of the process amount to more than six orders of magnitude. However, a practical proof of the required level of sterility assurance of 10–6 is not possible. Moreover, the attainability of this condition is fundamentally dubious, at least in non-thermal procedures. Thus, the question is discussed whether the undifferentiated adherence to the concept of sterility assurance on the basis of a single SAL of 10–6 corresponds with the safety requirements in terms of patient or user safety, costs and energy efficiency. Therefore, in terms of practical considerations, a concept of tiered SALs is recommended, analogous to the comparable and well-established categorization into “High-level disinfection”, “Intermediate-level disinfection” and “Low-level disinfection”. The determination of such tiered SALs is geared both to the intended application of the sterilized goods, as well as to the characteristics of the products and the corresponding treatment options. In the case of aseptic preparation, filling and production procedures, a mean contamination probability of 10–3 is assumed. In automated processes, lower contamination rates can be realized. In the case of the production of re-usable medical devices, a reduction of

  12. Sterile neutrinos at the CNGS

    NASA Astrophysics Data System (ADS)

    Donini, Andrea; Maltoni, Michele; Meloni, Davide; Migliozzi, Pasquale; Terranova, Francesco

    2007-12-01

    We study the potential of the CNGS beam in constraining the parameter space of a model with one sterile neutrino separated from three active ones by an Script O(eV2) mass-squared difference, Δ mSBL2. We perform our analysis using the OPERA detector as a reference (our analysis can be upgraded including a detailed simulation of the ICARUS detector). We point out that the channel with the largest potential to constrain the sterile neutrino parameter space at the CNGS beam is νμ→ντ. The reason for that is twofold: first, the active-sterile mixing angle that governs this oscillation is the less constrained by present experiments; second, this is the signal for which both OPERA and ICARUS have been designed, and thus benefits from an extremely low background. In our analysis we also took into account νμ→νe oscillations. We find that the CNGS potential to look for sterile neutrinos is limited with nominal intensity of the beam, but it is significantly enhanced with a factor 2 to 10 increase in the neutrino flux. Data from both channels allow us, in this case, to constrain further the four-neutrino model parameter space. Our results hold for any value of Δ mSBL2gtrsim0.1 eV2, i.e. when oscillations driven by this mass-squared difference are averaged. We have also checked that the bound on θ13 that can be put at the CNGS is not affected by the possible existence of sterile neutrinos.

  13. Reionization in sterile neutrino cosmologies

    NASA Astrophysics Data System (ADS)

    Bose, Sownak; Frenk, Carlos S.; Hou, Jun; Lacey, Cedric G.; Lovell, Mark R.

    2016-12-01

    We investigate the process of reionization in a model in which the dark matter is a warm elementary particle such as a sterile neutrino. We focus on models that are consistent with the dark matter decay interpretation of the recently detected line at 3.5 keV in the X-ray spectra of galaxies and clusters. In warm dark matter models, the primordial spectrum of density perturbations has a cut-off on the scale of dwarf galaxies. Structure formation therefore begins later than in the standard cold dark matter (CDM) model and very few objects form below the cut-off mass scale. To calculate the number of ionizing photons, we use the Durham semi-analytic model of galaxy formation, GALFORM. We find that even the most extreme 7 keV sterile neutrino we consider is able to reionize the Universe early enough to be compatible with the bounds on the epoch of reionization from Planck. This, perhaps surprising, result arises from the rapid build-up of high redshift galaxies in the sterile neutrino models which is also reflected in a faster evolution of their far-UV luminosity function between 10 > z > 7 than in CDM. The dominant sources of ionizing photons are systematically more massive in the sterile neutrino models than in CDM. As a consistency check on the models, we calculate the present-day luminosity function of satellites of Milky Way-like galaxies. When the satellites recently discovered in the Dark Energy Survey are taken into account, strong constraints are placed on viable sterile neutrino models.

  14. Plasma Sterilization Technology for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Fraser, S. J.; Olson, R. L.; Leavens, W. M.

    1975-01-01

    The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

  15. New developments in disinfection and sterilization.

    PubMed

    Wallace, Craig A

    2016-05-02

    A review of regulatory clearances for selected new sterilization and disinfection products for the period January 2012-June 2015 indicates continued leverage of established technologies for steam and low-temperature sterilization, and high-level disinfection. New products in these areas were typically modified and improved versions of existing products, with the exception of a new combination hydrogen peroxide/ozone sterilizer. Development of new low-temperature sterilization technologies to address continued evolution of complex medical devices is expected to continue.

  16. Assessment of Residual Moisture and Maintenance of Sterility in Surgical Instrument Sets after Sterilization.

    PubMed

    Fayard, Camille; Lambert, Christophe; Guimier-Pingault, Catherine; Levast, Marion; Germi, Raphaelle

    2015-08-01

    Good sterilization practices include discarding items containing residual moisture after steam sterilization. In this small laboratory study, however, the presence of residual water did not appear to compromise the sterility of surgical instruments in 2 commonly used types of packaging during routine storage after steam sterilization.

  17. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  18. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  19. Lessons from the recent rise in use of female sterilization in Malawi.

    PubMed

    Jacobstein, Roy

    2013-03-01

    Although female sterilization is the most widely used modern contraceptive method in the world, most family planning programs in Africa have had difficulty providing it. Malawi, however, despite daunting constraints, has made female sterilization widely and equitably accessible, thereby increasing method choice and helping its citizens better meet their reproductive intentions. Ten percent of currently married Malawian women of reproductive age rely on female sterilization for contraceptive protection, compared with less than 2 percent across Africa, and demand to limit births now exceeds demand to space births. Malawi's female sterilization prevalence surpasses that of some high-resource countries. Key service-delivery factors enabling this achievement include supportive policies, strong public-private partnerships, and mobile services delivered at no cost by dedicated providers. Challenges remain, but Malawi's achievement offers lessons for other countries with low availability of female sterilization and similar resource constraints.

  20. Microwave Sterilization and Depyrogenation System

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  1. Birth Control, Sterilization and Abortion

    PubMed Central

    Schneiderman, Lawrence J.; Prichard, Lorraine; Fuller, Scott; Atkinson, Leslie

    1974-01-01

    A questionnaire comprising case histories was administered to 27 Protestant and 27 Catholic clergymen in the San Diego area to test their attitudes toward the use of birth control, sterilization and abortion in families with specific genetic problems. The responses indicated: • Catholic and Protestant clergymen do not always follow the official positions of their churches in these matters, although the majority of them do. • Protestant clergymen were more likely to approve of birth control, sterilization, and abortion than Catholic clergymen. • The approval responses of Protestant and Catholic clergymen were not greatly influenced by whether the illness variables involved high Mendelian risk, high psychological cost, high social cost, or poor prognosis. • The approval responses of Protestant and Catholic clergymen were not significantly influenced by the socio-ethnic background of the families. PMID:4813802

  2. Counseling issues in tubal sterilization.

    PubMed

    Baill, I Cori; Cullins, Vanessa E; Pati, Sangeeta

    2003-03-15

    Female sterilization is the number one contraceptive choice among women in the United States. Counseling issues include ensuring that the woman understands the permanence of the procedure and knowing the factors that correlate with future regret. The clinician should be aware of the cumulative failure rate of the procedure, which is reported to be about 1.85 percent during a 10-year period. Complications of tubal sterilization include problems with anesthesia, hemorrhage, organ damage, and mortality. Some women who undergo tubal ligation may experience increased sexual satisfaction. While the procedure is commonly performed postpartum, it can be done readily, without relation to recent pregnancy, by laparoscopy or, when available, by minilaparotomy. Surgery should be timed immediately postpartum, or coincide with the first half of the woman's menstrual cycle or during a time period when the woman is using a reliable form of contraception.

  3. Implementing AORN recommended practices for sterilization.

    PubMed

    Graybill-D'Ercole, Patricia

    2013-05-01

    Any hospital or facility in which surgery and other invasive procedures are performed should have accommodations for cleaning, decontaminating, disinfecting, and sterilizing instruments, equipment, and other essential supplies that are used for patient procedures. Sterilization is essential to reducing or preventing the risk of surgical site infections. This is a collaborative process and should include all health care providers who handle these instruments, including perioperative nurses. The revised AORN "Recommended practices for sterilization," which became effective June 15, 2012, includes updates on sterilizing single-use items, inspecting critical items before sterilization, using low-temperature hydrogen peroxide vapor sterilization methods, and immediate use steam sterilization. This RP document is the first AORN document to be evidence rated and accepted for inclusion in the Agency for Healthcare Research and Quality National Guideline Clearinghouse. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  4. Method of sterilization using ozone

    NASA Technical Reports Server (NTRS)

    Murphy, Oliver J. (Inventor); Hitchens, G. Duncan (Inventor)

    2002-01-01

    Methods of using ozone have been developed which sterilize instruments and medical wastes, oxidize, organics found in wastewater, clean laundry, break down contaminants in soil into a form more readily digested by microbes, kill microorganisms present in food products, and destroy toxins present in food products. The preferred methods for killing microorganism and destroying toxins use pressurized, humidified, and concentrated ozone produced by an electrochemical cell.

  5. [Vasectomy and tubal ligation: medicopsychological aspects of voluntary sterilization].

    PubMed

    Bourgeois, M

    1982-06-01

    Various psychological aspects of voluntary surgical sterilization are examined. Women's own bodies are protected through sterilization from all the risks of pregnancy, but there is an altruistic element of vasectomy which may be perceived by men either positively or as a sacrifice or mutilition. The greater prevalence of female sterilization thus seems logical. Some psychologists view vasectomy as representing the realization of castration fantasies, but despite occurrence of cases which might seem to legitimate this view, most vasectomized men are married adults who have fathered several children and have otherwise proven their maturity. The status of voluntary sterilization appears to differ in the Third World, where rapid population growth threatens collective survival, and in developed countries whose growth rates are low or negative. Requests for reversal are increasingly frequent as women undergo sterilization at younger ages. Remarriage, a change of mind by the couple, or death of a child are the most frequently cited reasons for reversal requests. Reports of the psychological consequences of sterilization tend to vary in different studies, largely because of differences in the socioeconomic and cultural status of the populations studied and also perhaps because some studies are more superficial than others. In numerous questionnaire surveys mostly done in Anglo-Saxon countries, typically 90-99% of subjects have reported themselves satisfied with the results. The great majority report no regrets, an unchanged or improved marital relationship, and an increase in sexual pleasure. Less heterogeneous samples of persons undergoing sterilization for reasons other than simple contraceptive convenience have sometimes given less positive results. Age, economic status, number of children, marital relationship, educational level, religious and moral convictions, and history of medical or psychological problems can all affect satisfaction with sterilization. Men in

  6. Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer

    NASA Astrophysics Data System (ADS)

    Li, Si; Zhang, Yangde; Liu, Weidong

    2006-09-01

    The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.

  7. [Use of corrosion inhibitors during the sterilization and disinfection of medical instruments].

    PubMed

    Talalina, A S; Kochanova, L G; Anan'eva, A I; Romanova, A A

    1984-01-01

    The search of corrosion inhibitors reducing the corrosive action of the sterilizing and disinfecting media has been performed in order to protect instruments made of metals against corrosion during these processes. The program of the investigations includes potentiodynamic and potentiostatic measurements and full-scale tests. The infection of the sodium benzoate or potassium gluconate into the disinfecting chloramine solution and sterilizing hydrogene peroxide solution has been shown to improve the resistance to the corrosion for medical instruments made of carbon steel.

  8. Plasma Sterilization: New Epoch in Medical Textiles

    NASA Astrophysics Data System (ADS)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  9. A simple sterile polypropylene fingernail substitute.

    PubMed

    Tos, P; Artiaco, S; Coppolino, S; Conforti, L G; Battiston, B

    2009-06-01

    Traumatic nail injuries are often observed in clinical practice. Usually the fingernail can be preserved, cleaned and disinfected in order to use it in the reconstructive procedure. However, in some cases the nail can be avulsed and lost or too damaged to be used. In cases when the nail is not available it should be replaced by a substitute in order to protect nail bed and avoid adherences along the proximal nail bed and the nail fold. Furthermore the substitute serves to protect the tender nail bed from painful stimuli during the healing process. We used, as fingernail substitute, a polypropylene sheet in eight patients with fingernail avulsion or disruption. The polypropylene foil was trimmed reproducing the profile of the avulsed fingernail and thinned at the proximal edge to reduce thickness in order to ease the insertion into the nail fold. A small hole was then created in the center of the foil to allow blood drainage. The substitute was usually removed one month after the application. In our clinical experience we had not complications related to the polypropylene device. The new fingernail had good cosmetic appearance in most cases and all the patients reported a good protection of the fingertip during the healing period. The substitute used in this series is sterile, inexpensive and easily available in emergency and elective operatory theater. This polypropylene foil is flexible and can be shaped and adapted to the nail curvature radius. The substitute used in our clinical series protected the nail bed during healing until the growth of the new fingernail and respected our functional expectations.

  10. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

    PubMed

    Alfa, M J; DeGagne, P; Olson, N; Hizon, R

    1998-10-01

    The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

  11. Surgical sterilization, regret, and race: contemporary patterns.

    PubMed

    Shreffler, Karina M; McQuillan, Julia; Greil, Arthur L; Johnson, David R

    2015-03-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4592 women ages 25-45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Radiation sterilization of new drug delivery systems

    PubMed Central

    Abuhanoğlu, Gürhan

    2014-01-01

    Radiation sterilization has now become a commonly used method for sterilization of several active ingredients in drugs or drug delivery systems containing these substances. In this context, many applications have been performed on the human products that are required to be sterile, as well as on pharmaceutical products prepared to be developed. The new drug delivery systems designed to deliver the medication to the target tissue or organ, such as microspheres, nanospheres, microemulsion, and liposomal systems, have been sterilized by gamma (γ) and beta (β) rays, and more recently, by e-beam sterilization. In this review, the sterilization of new drug delivery systems was discussed other than conventional drug delivery systems by γ irradiation. PMID:24936306

  13. Radiation sterilization of new drug delivery systems.

    PubMed

    Abuhanoğlu, Gürhan; Ozer, A Yekta

    2014-06-01

    Radiation sterilization has now become a commonly used method for sterilization of several active ingredients in drugs or drug delivery systems containing these substances. In this context, many applications have been performed on the human products that are required to be sterile, as well as on pharmaceutical products prepared to be developed. The new drug delivery systems designed to deliver the medication to the target tissue or organ, such as microspheres, nanospheres, microemulsion, and liposomal systems, have been sterilized by gamma (γ) and beta (β) rays, and more recently, by e-beam sterilization. In this review, the sterilization of new drug delivery systems was discussed other than conventional drug delivery systems by γ irradiation.

  14. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    PubMed Central

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  15. Sterilization of products contaminated with Pyronema domesticum.

    PubMed

    Lampe, Carol M; Hansen, Joyce M; Rymer, Therese M; Sargent, Harold

    2009-01-01

    Product recalls due to non-sterility occurred between 1993 and 1994 among manufacturers that were sterilizing cotton products sourced from China using ethylene oxide (EO). The primary contaminant was identified as a pyrophilous mold from the class Discomycetes, Pyronema domesticum. Multiple references suggest this organism has special needs for reproducing and maintaining the two assumed resistant stages of this organism (ascospores and sclerotia). Sterilization resistance studies were performed using a China-sourced cotton product that was naturally contaminated with P. domesticum. These studies showed the organisms to have: 1) a low resistance to moist heat sterilization at 250 degrees F (121 degrees C); a resistance to radiation no greater than that predicted by the bioburden-based resistance model (i.e., Population C) used for dose determination Method 1 described in ANSI/AAMI/ISO 11137-2:2006--Sterilization of health care products--Radiation--Part 2: Establishing the sterilization dose; and 3) a high resistance to EO processing.

  16. Hysteroscopic Sterilization: History and Current Methods

    PubMed Central

    Greenberg, James A

    2008-01-01

    For many practicing obstetrician-gynecologists, tubal ligation was the gold standard by which female sterilization techniques were measured. Yet gynecologic surgeons have simultaneously sought to occlude the fallopian tubes transcervically to avoid discomfort and complications associated with transabdominal approaches. In this review, the history of transcervical sterilization is discussed. Past, current, and upcoming techniques are reviewed. This article focuses on interval sterilization techniques, thus removing post-vaginal and post-cesarean delivery tubal ligations from the discussion. PMID:19015762

  17. Sterile neutrino dark matter with supersymmetry

    NASA Astrophysics Data System (ADS)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  18. The Status of Sterile Neutrino Dark Matter

    NASA Astrophysics Data System (ADS)

    Horiuchi, Shunsaku

    2017-01-01

    The sterile neutrino is a particle dark matter candidate with a host of observable signatures that is close to being fully tested. I will first review the implications for structure formation, comparing predictions of sterile neutrino cosmologies against observations. I will then review analyses of X-rays from dark matter concentrations in search of mono-energetic photons predicted from sterile neutrino dark matter decays. Structure formation and X-rays offer important complementary probes, and I will highlight the recent rapid progress in testing the sterile neutrino parameter space. I will also discuss implications of analyses leading to the detection of X-ray lines from clusters of galaxies and Andromeda.

  19. Ramifications of a sterile Mars

    NASA Astrophysics Data System (ADS)

    Levin, Gilbert V.

    2011-10-01

    The seldom considered ramifications of a sterile Mars are explored. Very much is now known about the environment on Mars. Herein, the individual and collective environmental parameters are examined with particular consideration of those that might be inimical to life as we know it, or as might reasonably be assumed to be so to alien life. It is shown that no single measurement or combination of them precludes the ability of Mars to support even a wide number of terrestrial microbial species, let alone the likely greater tolerance and/or adaptability of possible alien life forms. Some yet unknown factor or combination of factors would have to be responsible for Mars' failure to generate life or to successfully harbor viable forms received from space. Since Mars is so Earth-like, the red planet's sterility could deliver a fatal blow to the growing concept of a cosmic Biologic Imperative, and would raise the daunting prospect that Earth is a unique or a very rare habitat.

  20. Steam quality and effective sterilization.

    PubMed

    Sedlacek, R S; Rose, E F

    1985-01-01

    Faced with using steam from a commercial utility having boilers greater than 5 miles distant and being the last user on the system resulted in ineffective sterilization. A three phase testing program was established utilizing: Direct physical measurements - an Ellison model 915A portable steam calorimeter. Direct microbiology - Autoclaved feed pellets were aseptically placed in fluid thioglycolate medium and incubated at 37 degrees C. Indirect microbiology - Feces from "defined flora" mice fed the autoclaved pelleted feed were tested. Colorimetric measurements verified that the steam sometimes contained greater than 5% entrained water. During periods of wet steam it was impossible to maintain consistent sterility of the mouse pellets even using a cycle of 126 degrees C for 60 minutes. One spore-forming Gram positive rod, Clostridium perfringens type D was the predominant bacterium isolated. Lactating mice, or mice stressed experimentally came down with diarrhea within days of eating pellets treated with wet steam (calorimetric measurements) and a subsequent positive culture. These mice voided stools predominantly showing Clostridium perfringens type D.

  1. Factors Influencing the Activity of Sterile Filtered and Heat-Sterilized Trypsin Solutions

    PubMed Central

    Cook, R. A.; Poole, G. M.

    1974-01-01

    The mode of sterilization (filtration or heat) was found to significantly affect the activity of trypsin solutions. Trypsin activity was substantially reduced in the initial fractions of filtrate passed through asbestos filter pads; heat-sterilized trypsin was satisfactory for transfer of cell cultures grown on glass. Heat-sterilized trypsin may be useful when elimination of filterable organisms is required. PMID:4844278

  2. Mars Sample Handling Protocol Workshop Series: Workshop 2a (Sterilization)

    NASA Technical Reports Server (NTRS)

    Rummel, John D. (Editor); Brunch, Carl W. (Editor); Setlow, Richard B. (Editor); DeVincenzi, Donald L. (Technical Monitor)

    2001-01-01

    The Space Studies Board of the National Research Council provided a series of recommendations to NASA on planetary protection requirements for future Mars sample return missions. One of the Board's key findings suggested, although current evidence of the martian surface suggests that life as we know it would not tolerate the planet's harsh environment, there remain 'plausible scenarios for extant microbial life on Mars.' Based on this conclusion, all samples returned from Mars should be considered potentially hazardous until it has been demonstrated that they are not. In response to the National Research Council's findings and recommendations, NASA has undertaken a series of workshops to address issues regarding NASA's proposed sample return missions. Work was previously undertaken at the Mars Sample Handling and Protocol Workshop 1 (March 2000) to formulate recommendations on effective methods for life detection and/or biohazard testing on returned samples. The NASA Planetary Protection Officer convened the Mars Sample Sterilization Workshop, the third in the Mars Sample Handling Protocol Workshop Series, on November 28-30, 2000 at the Holiday Inn Rosslyn Westpark, Arlington, Virginia. Because of the short timeframe between this Workshop and the second Workshop in the Series, which was convened in October 2000 in Bethesda, Maryland, they were developed in parallel, so the Sterilization Workshop and its report have therefore been designated as '2a'). The focus of Workshop 2a was to make recommendations for effective sterilization procedures for all phases of Mars sample return missions, and to answer the question of whether we can sterilize samples in such a way that the geological characteristics of the samples are not significantly altered.

  3. The therapeutic exception: abortion, sterilization and medical necessity in Costa Rica.

    PubMed

    Carranza, María

    2007-08-01

    Based on the case of Rosa, a nine-year-old girl who was denied a therapeutic abortion, this article analyzes the role played by the social in medical practice. For that purpose, it compares the different application of two similar pieces of legislation in Costa Rica, where both the practice of abortion and sterilization are restricted to the protection of health and life by the Penal Code. As a concept subject to interpretation, a broad conception of medical necessity could enable an ample use of the therapeutic exception and a liberal use of both surgeries. The practice of therapeutic sterilization has been generalized in Costa Rica and has become the legitimate way to distribute contraceptive sterilization. In contrast, therapeutic abortion is very rarely practiced. The analysis carried out proposes that it is the difference in social acceptance of abortion and sterilization that explains the different use that doctors, as gatekeepers of social morality, make of medical necessity.

  4. Sterile neutrino searches at future e-e+, pp and e-p colliders

    NASA Astrophysics Data System (ADS)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2017-05-01

    Sterile neutrinos are among the most attractive extensions of the SM to generate the light neutrino masses observed in neutrino oscillation experiments. When the sterile neutrinos are subject to a protective symmetry, they can have masses around the electroweak scale and potentially large neutrino Yukawa couplings, which makes them testable at planned future particle colliders. We systematically discuss the production and decay channels at electron-positron, proton-proton and electron-proton colliders and provide a complete list of the leading order signatures for sterile neutrino searches. Among other things, we discuss several novel search channels, and present a first look at the possible sensitivities for the active-sterile mixings and the heavy neutrino masses. We compare the performance of the different collider types and discuss their complementarity.

  5. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  6. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  7. An inexpensive laparoscopy system for female sterilization.

    PubMed

    Wheeless, C R

    1975-12-01

    Laparoscopy has become an established procedure for female sterilization. The cost of the equipment remains excessively high, thereby reducing its availability to all physicians and patients who desire and need it. We have described an inexpensive--but highly effective--female sterilization system utilizing equipment that should cost in the range of $400.00.

  8. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  9. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  10. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  11. Paraformaldehyde for Surface Sterilization and Detoxification

    PubMed Central

    Taylor, Larry A.; Barbeito, Manuel S.; Gremillion, Gardner G.

    1969-01-01

    Paraformaldehyde powder, depolymerized by heat, produced formaldehyde gas that was effective in sterilizing laboratory rooms, a mobile laboratory trailer, various surfaces, fiberglass filter medium, and specialized laboratory equipment. A sporulating and nonsporulating strain of bacteria, a virus, and a bacterial toxin were used as test agents. The dissemination procedures and equipment, the assay techniques, and the facilities and equipment sterilized were described. PMID:4977223

  12. Higgs production through sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2016-10-01

    In scenarios with sterile (right-handed) neutrinos with an approximate “lepton-number-like” symmetry, the heavy neutrinos (the mass eigenstates) can have masses around the electroweak scale and couple to the Higgs boson with, in principle, unsuppressed Yukawa couplings, while the smallness of the light neutrinos’ masses is guaranteed by the approximate symmetry. The on-shell production of the heavy neutrinos at lepton colliders, together with their subsequent decays into a light neutrino and a Higgs boson, constitutes a resonant contribution to the Higgs production mechanism. This resonant mono-Higgs production mechanism can contribute significantly to the mono-Higgs observables at future lepton colliders. A dedicated search for the heavy neutrinos in this channel exhibits sensitivities for the electron neutrino Yukawa coupling as small as ˜ 5 × 10-3. Furthermore, the sensitivity is enhanced for higher center-of-mass energies, when identical integrated luminosities are considered.

  13. Disinfection, sterilization, and antisepsis: An overview.

    PubMed

    Rutala, William A; Weber, David J

    2016-05-02

    All invasive procedures involve contact by a medical device or surgical instrument with a patient's sterile tissue or mucous membranes. The level of disinfection or sterilization is dependent on the intended use of the object: critical (items that contact sterile tissue such as surgical instruments), semicritical (items that contact mucous membrane such as endoscopes), and noncritical (devices that contact only intact skin such as stethoscopes) items require sterilization, high-level disinfection and low-level disinfection, respectively. Cleaning must always precede high-level disinfection and sterilization. Antiseptics are essential to infection prevention as part of a hand hygiene program as well as several other uses such as surgical hand antisepsis and pre-operative skin preparation.

  14. Care and sterilization of endourologic instruments.

    PubMed

    Gregory, E; Simmons, D; Weinberg, J J

    1988-08-01

    All endourologic instruments must be handled properly if they are to continue to function properly. Care must be taken in washing and sterilizing of this equipment, as not all endoscopic equipment can endure all methods, and people who are working with these instruments must be taught the proper care and sterilization methods of each. For example, fiberoptic telescopes and light cables must never be autoclaved; ethylene oxide is the method of choice. Disinfectant is an alternative. Loops, sheaths, high-frequency cables, resectoscopes, and working elements should be sterilized by ethylene oxide. Loops and high-frequency cables should not be soaked in a disinfectant, but other instruments may be soaked. All instruments should be dried before sterilization. Too much emphasis cannot be placed on the importance of proper storage of these very fragile fiberoptic instruments. With proper care and sterilization, these instruments will need fewer repairs and function properly for a longer time.

  15. Sterilization: women fit to be tied.

    PubMed

    Caress, B

    1975-01-01

    Sterilization abuse is both systematic and widespread. Frequently, women are misled about the dangers of surgery, misinformed about its permanence, and coerced while under the stress of labor or abortion. Generally, instances of abuses in the health system are treated as illegitimate, illegal aberations of an otherwise decent health care system. Careful examination of these so called abuses would reveal that each can be causally connected to particular aspects of the care of America's health system. Sterilization abuse stems from a combination of factors inherent in the health system plus 1 critical additional factor. Besides resulting from teaching and research imperatives, profit making, and the fee for service systems, such abuse is the most widespread example of medicine as an instrument of social control. Sterilization is the most extreme form of birth control and birth control is official US government policy. There were about 500,000 sterilizations performed on American women in 1973. None of the sterilization methods is innocuous, and each is associated with some physical and psychological side effects. General agreement exists in the medical literature that some risk is attendant to each procedure. Sterilization is the most dangerous and the fastest growing method of birth control. Since 1970 the figures show an almost 3-fold increase in the incidence of female sterilization, from 192,000 in 1970 to 548,000 in 1974. Much evidence exists to suggest that the increase in the number of sterilizations has fueled a trend toward the sterilization of younger women with fewer children. Official accommodation to liberalization of sterilization practices in the US came in 1969, when the American College of Obstetricians and Gynecologists (ACOG) withdrew its age parity formula. This liberalization of sterilization guidelines opened the floodgates to abuse. Some of the increase in the number of operations performed is due to increased demand, some of it is the result

  16. Problems in sterilization of unmanned space vehicles.

    PubMed

    Jaffe, L D

    1964-01-01

    The probability of achieving and maintaining sterility of an unmanned spacecraft with varied suggested procedures is examined in detail, as are alternative techniques for avoiding biological contamination of the planets. The required degree of assurance against contamination of Mars, Venus and the Moon with Earth organisms is also considered. For Mars landers and orbiters, sterilization of the spacecraft or capsule by dry heat, with no subsequent access, is found to be desirable. For the present, sterilization of Venus landers still seems desirable. For Mars flybys, and for Venus orbiters and flybys, control of the trajectory to minimize the chance of unintentionally entering the planetary atmosphere appears the method of choice. For the Moon, sterilization seems unnecessary, but microbial counts should be kept low. Sterilization lowers spacecraft and system reliability. It reduces the chance of launching within periods fixed by astronomical constraints and increases costs. The gain which should be achieved through spacecraft sterilization, in return of significant biological information about the planets, must be balanced against these losses. In particular, one should keep in mind the loss in return of biological data occasioned by failure of a spacecraft to fulfill its mission; the probability of such failure is increased by sterilization.

  17. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  18. Parameters governing steam sterilization of deadlegs.

    PubMed

    Young, J H; Ferko, B L; Gaber, R P

    1994-01-01

    Use of saturated steam for sterilization-in-place (SIP) is limited by factors effecting displacement of air from deadlegs. Effects of tube diameter, length, orientation and position within a deadleg were quantitatively studied by examining temperature profiles and rates of kill of Bacillus stearothermophilus spores. Tube diameter had the greatest effect on sterilization. For small diameter tubes, 0.4 cm inside diameter (ID), air displacement was minimal and due mainly to diffusion. 8.8 cm long tubes with 0.4 cm IDs could not be sterilized at 121 degrees C. As tube diameter was increased and buoyant driven convective flow became dominant over viscous forces, sterilization was achieved and tube orientation became critical. Sterilization time, as defined by a twelve log reduction in spore population, was 75 minutes in a 19.0 cm long vertical tube with 1.7 cm ID, whereas 167 minutes were required for an 8.8 cm long tube with 1.0 cm ID. For 8.8 cm long tubes, only the 1.7 cm ID tube could be sterilized when orientated 5 degrees above horizontal. Data show that length to diameter ratios, L/Ds, do not provide a general guideline which can be used to predict sterilization. In the absence of steam bleeders, equipment should be designed to assure strong buoyancy driven convective flow to assure adequate air removal. This requires elimination of small diameter deadlegs (0.4 cm ID and less) and vertical positioning of deadlegs.

  19. New sterilization technologies alternative to ethylene oxide

    NASA Astrophysics Data System (ADS)

    Tabrizian, Maryam; Lerouge, Sophie; Debrie, Anne; Yahia, L'Hocine

    1997-06-01

    Sterilization of biomedical devices may induce bulk and surface modification, responsible for the decrease or loss of their biofunctionality. Pure ethylene oxide (EO) at low temperature and new alternative techniques such as cold gas plasma sterilization have been developed for heat-sensitive polymers. There is a lack of the knowledge concerning their safety in terms of materials damage and consequences on the biofunctionality of sterilized devices. The objective of our work consists in studying bulk and surface changes in biomedical devices induced by these two sterilization techniques. Samples from PVC, Polyurethane, Polyacrylate and Polyethylene-based medical devices are subjected to 1, 5, and 10 sterilization cycles by Steri-Vac-3M (pure EO), Sterrad-100$TM, J&J (gas plasma + H2O2), and studied by X-rays photoelectron spectroscopy. Preliminary results show an increasing in Oxygen/Carbon ratio by a factor of 1.3 to 4.4 between the first and tenth cycle indicating the surface oxidation by gas plasma sterilization processes. Some changes in C-C chemical bounding are associated with EO sterilization.

  20. An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft

    NASA Technical Reports Server (NTRS)

    Farmer, F. H.; Fuller, H. V.; Hueschen, R. M.

    1973-01-01

    A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.

  1. The efficacy of low temperature plasma (LTP) sterilization, a new sterilization technique.

    PubMed

    Höller, C; Martiny, H; Christiansen, B; Rüden, H; Gundermann, K O

    1993-07-01

    The efficacy of low temperature plasma (LTP) sterilization, a newly developed sterilization procedure was tested. Following experiments were carried out: Determination of the most resistant test organism, influence of 10% and 20% defibrinated sheep blood or varying salt concentrations on the efficacy of the sterilization process, influence of the carrier position in the sterilization chamber and in the sterilization pouches, influence of a loaded sterilization chamber, comparative efficacy of EO and LTP, steel carriers with a blood burden of 0%, 5% and 10%, comparative efficacy of EO and LTP, strip carriers in endoscopes, blood burden 0% and 10%, with and without adaptors, evaluation of two bioindicator models. B. pumilus was the test spore that overall seemed to be most resistant to the sterilization procedure. Supplementation of the test suspension with blood or saline crystals resulted in significantly reduced efficacy and has to be avoided in practical operation. The fully loaded sterilization chamber or the position of germ carriers on the shelves had no negative influence on the effectivity of the sterilization process. There were no significant differences between EO and LTP, the blood burden not exceeding 5%. 10% blood burden resulted in a significantly weaker action of LTP. For sterilization of long lumens adaptors containing hydrogen peroxide are necessary. An appropriate bioindicator tube model is introduced.

  2. Complications of female sterilization: immediate and delayed.

    PubMed

    Huggins, G R; Sondheimer, S J

    1984-03-01

    Surgical sterilization in women has changed dramatically over the past 20 years. The development of laparoscopy and minilaparotomy have made the procedure readily available even in developing countries. In the United States, changing social values and changes in hospital regulations have done as much as technology to account for the tremendous increases in the number of women undergoing sterilization. Improved sterilization procedures have resulted in lower costs for sterilization and lowered morbidity and mortality rates. Hysterectomy for sterilization alone carries unacceptable morbidity and mortality rates. Originally, laparoscopic techniques utilized unipolar cautery. However, bowel burns, a rare but serious complication, were reported, and this led to newer techniques. These techniques, using bands, clips, and bipolar cautery, have gained increasing popularity and have eliminated many of the serious complications of female sterilization. Historically, there has been concern that tubal sterilization by any method produces, in significant numbers of patients, the subsequent gynecologic and psychologic problems called "post-tubal ligation syndrome." A review of earlier literature indicates that many of these studies have serious methodologic problems, including recall bias, inappropriate control groups, failure to elicit prior history of gynecologic or psychologic problems, and failure to account for the use of oral contraceptives or IUDs. More recent large prospective epidemiologic studies that have controlled for prior gynecologic problems and contraceptive usage have failed to show increased incidence of gynecologic sequelae in large numbers of women. However, there are some data to support the concept that in certain individuals, sterilization may result in disruption of ovarian blood or nerve supply, producing gynecologic sequelae. Additional data from these ongoing large-scale studies and others should help to elucidate this problem in the future. Pregnancy

  3. Chemical sterilization of allograft dermal tissues.

    PubMed

    Phipps, Abigail; Vaynshteyn, Edward; Kowalski, John B; Ngo, Manh-Dan; Merritt, Karen; Osborne, Joel; Chnari, Evangelia

    2017-08-10

    Common terminal sterilization methods are known to alter the natural structure and properties of soft tissues. One approach to providing safe grafts with preserved biological properties is the combination of a validated chemical sterilization process followed by an aseptic packaging process. This combination of processes is an accepted method for production of sterile healthcare products as described in ANSI/AAMI ST67:2011. This article describes the validation of the peracetic acid and ethanol-based (PAAE) chemical sterilization process for allograft dermal tissues at the Musculoskeletal Transplant Foundation (MTF, Edison, NJ). The sterilization capability of the PAAE solution used during routine production of aseptically processed dermal tissue forms was determined based on requirements of relevant ISO standards, ISO 14161:2009 and ISO 14937:2009. The resistance of spores of Bacillus subtilis, Clostridium sporogenes, Mycobacterium terrae, Pseudomonas aeruginosa, Enterococcus faecium, and Staphylococcus aureus to the chemical sterilization process employed by MTF was determined. Using a worst-case scenario testing strategy, the D value was calculated for the most resistant microorganism, Bacillus. The 12D time parameter determined the minimum time required to achieve a SAL of 10(-6). Microbiological performance qualification demonstrated a complete kill of 10(6) spores at just a quarter of the full cycle time. The validation demonstrated that the PAAE sterilization process is robust, achieves sterilization of allograft dermal tissue to a SAL 10(-6), and that in combination with aseptic processing secures the microbiological safety of allograft dermal tissue while avoiding structural and biochemical tissue damage previously observed with other sterilization methods such as ionizing irradiation.

  4. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    PubMed Central

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  5. Relationship between lumen diameter and length sterilized in the 125L ozone sterilizer.

    PubMed

    Dufresne, Sylvie; Leblond, Hélène; Chaunet, Marc

    2008-05-01

    A safe alternative to ethylene oxide for reprocessing heat-sensitive lumen medical devices, such as endoscopes, is needed. The effectiveness of a new, safe, low-cost, and environmentally friendly low-temperature sterilization process using ozone was assessed. Rigid lumen devices were used to assess the maximum length of lumens of different internal diameters that can be sterilized in the TSO(3) model 125L ozone sterilizer. Two inoculation techniques were used. An inoculated wire was placed inside lumens with internal diameters of 0.8 mm and larger, whereas lumens with an internal diameter of 0.5 mm were inoculated directly. Lumens with internal diameters of 0.5 mm, 1 mm, 2 mm, 3 mm, and 4 mm with lengths varying between 45 and 70 cm can be sterilized with ozone. Calculation of the log reduction value for each size demonstrated the achievement of a sterility assurance level of 10(-6). Experimental results demonstrated a linear relationship (with r(2) = 0.990) between the length of lumen that can be sterilized in the 125L ozone sterilizer and its internal diameter. Effective sterilization of an ACMI ureteroscope that is more challenging in terms of sterilant penetration in a small lumen (0.8 mm) compared with the stated lumen claims confirms that the relationship can conservatively be used to predict the length of a lumen device that can be sterilized in the 125L ozone sterilizer for a given diameter. Intermediate sizes of lumen devices that can be sterilized in the 125L ozone sterilizer can be interpolated from the linear relationship between diameter and length found in the present study.

  6. Microscope sterility during spine surgery.

    PubMed

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  7. Access to postpartum sterilization in southeast Brazil.

    PubMed

    Janowitz, B; Higgins, J E; Clopton, D C; Nakamura, M S; Brown, M L

    1982-05-01

    All women hospitalized for delivery over a ten-week period at the largest maternity hospital in Campinas in the State of São Paulo, Brazil, were questioned about their interest in and plans for sterilization. Results from a categorical data analysis indicate that among the study variables, cesarean delivery was the necessary condition for postpartum sterilization and was significantly associated with the patient's ability to pay for services. Further, the variability in the proportion of women sterilized postpartum was almost perfectly explained by a linear model with main effects for parity and for the patient's ability to pay for services.

  8. Basics of sterile compounding: bubble point testing.

    PubMed

    Thoma, Laura

    2014-01-01

    Compounding pharmacies that compound sterile preparations must choose sterile filters that are approved for human use. They may rely on the filter manufacturer's Certificate of Quality to ensure the sterile filter is pyrogen free and has been tested for bacterial retention. The Certificate of Quality from the filter manufacturer also contains other useful information about the filter such as: flow rate and maximum pressure drop, thermal and hydraulic stress, and membrane results of the initial integrity test performed on the filter membrane with water, if a hydrophilic membrane. This article discusses the integrity test, which is often called the water bubble point test.

  9. Spore-Forming Bacteria that Resist Sterilization

    NASA Technical Reports Server (NTRS)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  10. Observations on female sterilization in Chile.

    PubMed

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  11. Understanding current steam sterilization recommendations and guidelines.

    PubMed

    Spry, Cynthia

    2008-10-01

    Processing surgical instruments in preparation for surgery is a complex multistep practice. It is impractical to culture each and every item to determine sterility; therefore, the best assurance of a sterile product is careful execution of every step in the process coupled with an ongoing quality control program. Perioperative staff nurses and managers responsible for instrument processing, whether for a single instrument or multiple sets, must be knowledgeable with regard to cleaning; packaging; cycle selection; and the use of physical, chemical, and biological monitors. Nurses also should be able to resolve issues related to loaner sets, flash sterilization, and extended cycles.

  12. Determination of conditions for the production scale sterilization of prefilled syringes.

    PubMed

    Nishimoto, Norihiro; Maekawa, Tatsuyuki

    2003-01-01

    External and internal differences in pressure of prefilled syringes can cause plunger movement during sterilization, which might cause drug product contamination. Consequently the pressure inside the autoclave during sterilization should be controlled carefully to prevent contamination of the drug product by microorganism and particulates. A previously determined theoretical relationship of temperature to pressure in sealed bottles was modified for prefilled syringes to take plunger movement into account. This modification yielded a correction factor that includes a coefficient of linear thermal expansion for the syringe, thermal expansion of the plunger, and friction between the plunger and the syringe wall. To confirm the accuracy of this modified relationship, 100 mL polypropylene prefilled syringes with butyl rubber plungers, some of which carried pressure and temperature sensors, were used to test various sterilization conditions at the experimental scale. The results showed that the major problem in establishing the pressure conditions for production scale sterilization is temperature distribution throughout the load. However, an over pressure sterilization cycle at 121 degrees C and 0.34 MPa showed the best results. Microbial challenge and light-obscuration particle count tests were performed on the syringes from the worst-case location predicted from modified relationship; the results show that these conditions preserved the sterility of the drug product and protected it from particulate contamination.

  13. Sex and the sacred: sterilization and bodily integrity in English and Canadian law.

    PubMed

    Savell, Kristin

    2004-10-01

    Through an examination of cases of non-consensual sterilization for learning disabled persons in Canada and England, this article considers the role that law plays in framing the thoughts, beliefs, and norms that fashion the ways we think about bodies, sex, gender, and sexuality. The author asks how it is that Canadian and English law, while both claiming to protect bodily integrity, have reached opposing conclusions about whether non-therapeutic sterilization can be in a person's best interests. She hypothesizes that the answer could lie in the manner in which courts have constructed the bodies of learning disabled men and women in the sphere of sexuality and reproduction. Where the overriding concern in the sterilization cases is the containment of the sexuality of a learning disabled person perceived as "out of control" or "vulnerable to seduction", sterilization is cast as a just and humane solution that will advance the welfare of the individual concerned. Conversely, where the overriding concern is the preservation of the integrity of a law committed to the principle of equality, sterilization is thought to be a violation of the bodily integrity of the person. The author shows that these two views engender very different legal and cultural discourses about best interests and bodily integrity. The debate highlighted by the sterilization cases and the commentary surrounding them reflect larger tension within legal discourse between the commitment to liberal values and the maintenance of a particular social order.

  14. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires.

    PubMed

    Pernier, C; Grosgogeat, B; Ponsonnet, L; Benay, G; Lissac, M

    2005-02-01

    Orthodontic wires are frequently packaged in individual sealed bags in order to avoid cross-contamination. The instructions on the wrapper generally advise autoclave sterilization of the package and its contents if additional protection is desired. However, sterilization can modify the surface parameters and the mechanical properties of many types of material. The aim of this research was to determine the influence of one of the most widely used sterilization processes, autoclaving (18 minutes at 134 degrees C, as recommended by the French Ministry of Health), on the surface parameters and mechanical properties of six wires currently used in orthodontics (one stainless steel alloy: Tru-Chrome RMO; two nickel-titanium shape memory alloys: Neo Sentalloy and Neo Sentalloy with Ionguard GAC; and three titanium-molybdenum alloys: TMA(R) and Low Friction TMA Ormco and Resolve GAC). The alloys were analysed on receipt and after sterilization, using surface structure observation techniques, including optical, scanning electron and atomic force microscopy and profilometry. The mechanical properties were assessed by three-point bending tests. The results showed that autoclave sterilization had no adverse effects on the surface parameters or on the selected mechanical properties. This supports the possibility for practitioners to systematically sterilize wires before placing them in the oral environment.

  15. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    NASA Astrophysics Data System (ADS)

    Urquidi, Jacob; Brar, Ramaninder K.; Rodriguez, Stacy; Hansen, Immo

    2015-07-01

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today's global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males' longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.

  16. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    SciTech Connect

    Urquidi, Jacob Brar, Ramaninder K.; Rodriguez, Stacy; Hansen, Immo

    2015-07-23

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today’s global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males’ longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.

  17. Effect of ozone on sterilization of Penicillium digitatum using non-equilibrium atmospheric pressure plasma

    NASA Astrophysics Data System (ADS)

    Ohta, Takayuki; Iseki, Sachiko; Ito, Masafumi; Kano, Hiroyuki; Higashijima, Yasuhiro; Hori, Masaru

    2008-10-01

    Methyl bromide has been sprayed to the crops for protecting from insects and virus, but has high ozone depletion potential. Thus, the development of substitute-technology has been strongly required. We have investigated a plasma sterilization for spores of Penicillium digitatum, which causes green mold disease of the crops, using non-equilibrium atmospheric pressure plasma. The sterilization was caused by UV light, ozone, O and OH radicals. In this study, ozone density was measured and the effect to sterilization was discussed. The plasma was generated at an alternative current of 6kV and Ar gas flow rate of 3L/min. In order to investigate the sterilization mechanism of ozone, the absolute density of ozone was measured using ultraviolet absorption spectroscopy and was from 2 to 8 ppm. The sterilization by this plasma was larger than that by the ozonizer (03:600ppm). It is confirmed that the effect of ozone to the sterilization of Penicillium digitatum would be small.

  18. Sterile post-traumatic immunosuppression

    PubMed Central

    Islam, Md Nahidul; Bradley, Benjamin A; Ceredig, Rhodri

    2016-01-01

    After major trauma, the human immune system initiates a series of inflammatory events at the injury site that is later followed by suppression of local inflammation favoring the repair and remodeling of the damaged tissues. This local immune response involves complex interactions between resident cells such as macrophages and dendritic cells, soluble mediators such as cytokines and chemokines, and recruited cells such as neutrophils, monocytes and mesenchymal stromal cells. If of sufficient magnitude, these initial immune responses nevertheless have systemic consequences resulting in a state called post-traumatic immunosuppression (PTI). However, controversy exists regarding the exact immunological changes occurring in systemic compartments triggered by these local immune responses. PTI is one of the leading causes of post-surgical mortality and makes patients vulnerable to hospital-acquired infections, multiple organ failure and many other complications. In addition, hemorrhage, blood transfusion, immunesenescence and immunosuppressant drugs aggravate PTI. PTI has been intensively studied, but published results are frequently cloudy. The purpose of this review is to focus on the contributions made by different responsive modalities to immunosuppression following sterile trauma and to try to integrate these into an overall scheme of PTI. PMID:27195120

  19. [Positive and negative aspects of Fallopian tube sterilization as viewed by sterilized women

    PubMed

    Minella

    1998-03-30

    The objective of this paper is to point out the positive and negative aspects of female sterilization as seen by two groups of sterilized women in Florianópolis, Santa Catarina, Brazil, based on a sociological discussion of their present health status, evaluating the associations that they generally make with the fact that they have been sterilized. The first group included mostly housewives from a low-income neighborhood, while the second involved upper-middle-class female public employees, students, and university professors, totaling 40 women. Data were obtained through a structured questionnaire with open-ended questions. Information on social, economic, and demographic variables was recorded, along with subjective data associated with women's representations of the post-sterilization period. We concluded that there was no consensus as to the consequences of sterilization, since a number of the women (11/40), mostly sterilized before the age of 30, perceived changes in their health status after surgery.

  20. Risk of wound and pelvic infection after laparoscopic tubal sterilization: instrument disinfection versus sterilization.

    PubMed

    Huezo, C M; DeStefano, F; Rubin, G L; Ory, H W

    1983-05-01

    To determine if disinfection, rather than sterilization, of laparoscopic equipment leads to an increase in the risk of postlaparoscopy infection, the authors analyzed data from a multicenter prospective study conducted by the Centers for Disease Control on the safety of sterilizing operations. From September 1978 through July 1981, 3903 women underwent laparoscopic tubal sterilization procedures in which the equipment was sterilized with ethylene oxide (58%) or disinfected with glutaraldehyde (42%). The overall risk of wound infection in each group was 1.5 per 100 women. The relative risk of wound infection for disinfection versus sterilization of the equipment was 0.5 when adjusted for differences in the two groups. The corresponding relative risk of pelvic infection was 1.2. These results suggest that laparoscopy equipment disinfected with glutaraldehyde is not associated with an increased risk of wound or pelvic infection compared with equipment sterilized with ethylene oxide.

  1. Evaluation removes obstacles to sterilization in Brazil.

    PubMed

    1985-01-01

    In 1978, Centro de Pesquisas de Assitencia Integrada a Mulher e a Crianca (CPAIMC) in Rio de Janeiro began to offer interval sterilizations in an attempt to increase the access of poor women to sterilization services. By the end of 1984, the program had provided in excess of 19,000 sterilizations, making CPAIMC Brazil's largest single source of voluntary interval sterilization. Despite the program's success, CPAIMC was concerned that obstacles still existed in the poor woman's path to sterilization access. A study was conducted by Family Health International (FHI) in collaboration with the Pathfinder Fund and CPAIMC's Department of Information, Evaluation and Research to locate possible barriers. The study indicated that less than half of the women who requested sterilization between June 1 and August 31, 1983 actually had the procedure. During that period, 1256 women requested sterilization at the CPAIMC clinic. Of these, 925 were approved, and 639 were scheduled for surgery. Only 559 were actually sterilized within 3 months of receiving approval. 1 possible reason why women were not receiving the surgery was that the women requesting sterilization actually were not highly motivated to obtain the service. Yet, study results indicate this probably was not the reason. During initial interviews at the clinic, many women said they had thought very carefully about being sterilized, and more than 40% reported deciding to have a tubal ligation before their last pregnancy. Almost 3/4 of the women reported that they did not plan their last pregnancy, and almost 2/3 indicated that the pregnancy was unwanted. About 63% were contracepting, and many were using effective methods. More than half of the non-contraceptors were not using a method because they had just ended a pregnancy and were not sexually active. As a group, the women requesting sterilization were highly motivated to avoid having more children. Age and number of children were the most important criteria used by

  2. Low-temperature sterilization and new technologies.

    PubMed

    Goveia, Vania Regina; Pinheiro, Silma Maria Cunha; Graziano, Kazuko Uchikawa

    2007-01-01

    The new low-temperature sterilization technologies are presented as an alternative to the use of ethylene oxide. This review was performed in order to identify evidences of the antimicrobial activity, toxicity, adverse events and the applicability of these technologies. The research was carried through the electronic databases MEDLINE and LILACS up to 2005. The authors analyzed 10 articles in this survey. The studies about the efficacy of these sterilization methods constitute experimental and comparative research that showed the influence of the extension and diameter of the lumen, besides the presence of crystal salts. Thus, choosing the correct equipment is essential, as well as the assurance of the cleansing of the devices, which interfere with the effectiveness of the low-temperature sterilization. These technologies present limitations regarding the sterilization of graft bone and affect the materials properties.

  3. Ethylene oxide sterilization: the way ahead.

    PubMed

    Peacock, R

    1999-01-01

    Despite many predictions about the demise of ethylene oxide as a sterilization method, it continues to be used for increasing volumes of medical devices. This article examines why this has happened and what the future holds.

  4. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: Sterilization to polyurethane

    NASA Astrophysics Data System (ADS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu

    1995-09-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization.

  5. Cosmological and astrophysical implications of sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Petraki, Kalliopi

    The discovery of neutrino masses suggests that the Standard Model should be supplemented with new gauge-singlet fermions, often called sterile neutrinos. The interplay among the new couplings introduced in the Standard Model can accommodate the neutrino oscillation data for a variety of choices: the new particles can be extremely heavy and practically unobservable, or they can be light, in which case they can solve several long-standing puzzles. It has been shown, for example, that sterile neutrinos in some range of masses can account for dark matter, their emission from a supernova can explain pulsar kicks, arid their decays can play an important role in the formation of the first stars. Though indirect, these clues indicate that sterile neutrinos can be the minimal solution to a variety of unsolved problems. This emphasizes the importance of investigating further the consequences of these new degrees of freedom for cosmology and astrophysics. In this dissertation, I explore the possible role of sterile neutrinos of different mass scales in some cosmological and astrophysical phenomena. A minimal extension of the Higgs sector of the Standard Model, with a gauge- singlet boson coupled to sterile neutrinos, can provide a consistent framework for the theory of neutrino masses, and can produce a relic population of keV sterile neutrinos via decays of the singlet Higgs. The latter can account for the dark matter of the universe. The mechanism operates around the electroweak scale, and has interesting consequences for the electroweak phase transition. Relic sterile neutrinos produced via decays at the electroweak scale constitute colder dark matter than those produced via other previously suggested mechanisms. The primordial thermal content of dark matter has important implications for the formation of cosmic structures, such as clusters and galaxies. The assessment of the relevant properties suggests that sterile neutrinos produced at the electroweak scale are a

  6. Standard aeration for gas-sterilized plastics.

    PubMed Central

    White, J. D.

    1977-01-01

    In an effort to provide guidelines for standardizing aeration times for plastics sterilized with ethylene oxide, an Aeration Index has been developed. Based on the rate of diffusion of ethylene oxide in selected polymers, the Index provides an indication of the aeration time at ambient temperature (23 degrees C) for the ethylene oxide concentration in freshly sterilized plastics to drop to 50 parts/10(6). PMID:269198

  7. Ethylene Oxide Gas Sterilization of Medical Devices.

    PubMed

    Shintani, Hideharu

    2017-01-01

     Ethylene oxide gas is an agent in the sterilization of medical devices due to its effectiveness and compatibility with most materials. The advantages and disadvantages, as well as its recommended uses, are explored in this review article. The variables and their relevance on process optimization are described, the types of processing cycles are detailed and emphasis is given to the design and validation of the sterilization process.

  8. [Experimental tests of a microwave sterilization system].

    PubMed

    Rosaspina, S; Liguori, G; Anzanel, D; Finzi, G; Salvatorelli, G

    1994-01-01

    Data obtained in our experiments indicate that the microwave sterilization system utilized may be considered as a practical and rapid method for decontaminating steel surgical instruments. For the tested organisms (7 Gram- and 2 Gram+ genera) a 3' exposure time to microwaves provides successful sterilization. Microwave irradiation also had a killing action against Bacillus subtilis spores. A study by SEM of microwave treated spores shows typical morphological alterations of spore surfaces.

  9. Low-energy sterile neutrinos: Theory

    NASA Astrophysics Data System (ADS)

    Palazzo, Antonio

    2013-04-01

    Several experimental anomalies seem to point towards the existence of light sterile neutrinos. We focus on the low-energy anomalous results (the so-called gallium and reactor anomalies), which indicate a non-zero admixture U of the electron neutrino with a fourth (mostly) sterile mass eigenstate ν4. We point out that solar sector data, in combination with the precision measurement of θ13, provide the constraint |<0.041 (90% C.L.), independent of the reactor flux determinations.

  10. Experimental Study of Sterilizing Molds by Ultrasound

    NASA Astrophysics Data System (ADS)

    Ren, Jin-lian; Niu, Yong

    1998-02-01

    An ultrasound method of sterilizing aspergillus flavus and fusarium is proposed and demonstrated. The dependence of sterilizing effect on ultrasonic intensity, frequency, and treatment time is experimentally investigated. The density of surviving spores decreases first with increasing ultrasonic frequency and then increases with the further increase of the frequency, that is to say, there exists the optimum frequency 26 kHz at which the killing rate is near 100%. The killing rate seems proportional to the intensity and the time.

  11. Methods of Sterilization and Monitoring of Sterilization AcrossSelected Dental Practices in Karachi, Pakistan.

    PubMed

    Ahmed, Hina

    2015-10-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Cross-sectional, descriptive study. Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization.

  12. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  13. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  14. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions...

  15. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions...

  16. [Low-temperature sterilization for the surgical infection prophylaxis].

    PubMed

    Kornev, I I; Baranov, G A; Ul'ianov, V I

    2011-01-01

    The comparative characteristic of the accepted methods of low-temperature sterilization of medical equipment is given. Special attention is devoted to the surgical infection prophylaxis. The efficacy, expediency and safety of gas sterilization with ethilenoxide is proved. Plasmic methods of sterilization is recommended for use together with other methods of low-temperature sterilization.

  17. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  18. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  19. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  20. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  1. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  2. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  3. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  4. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  5. Sterile neutrinos facing kaon physics experiments

    NASA Astrophysics Data System (ADS)

    Abada, A.; Bečirević, D.; Sumensari, O.; Weiland, C.; Funchal, R. Zukanovich

    2017-04-01

    We discuss weak kaon decays in a scenario in which the Standard Model is extended by massive sterile fermions. After revisiting the analytical expressions for leptonic and semileptonic decays we derive the expressions for decay rates with two neutrinos in the final state. By using a simple effective model with only one sterile neutrino, compatible with all current experimental bounds and general theoretical constraints, we conduct a thorough numerical analysis which reveals that the impact of the presence of massive sterile neutrinos on kaon weak decays is very small, less than 1% on decay rates. The only exception is B (KL→ν ν ) , which can go up to O (10-10), thus possibly within the reach of the KOTO, NA62 and SHIP experiments. Plans have also been proposed to search for this decay at the NA64 experiment. In other words, if all the future measurements of weak kaon decays turn out to be compatible with the Standard Model predictions, this will not rule out the existence of massive light sterile neutrinos with non-negligible active-sterile mixing. Instead, for a sterile neutrino of mass below mK, one might obtain a huge enhancement of B (KL→ν ν ), otherwise negligibly small in the Standard Model.

  6. Sterilization chosen by 11 million Americans.

    PubMed

    1979-12-01

    Nearly 11 million Americans have chosen surgical sterilization as their contraceptive method; about 1,131,000 procedures were obtained in 1978, 670,000 women and 461,000 men. In 1960 the ratio of male to female sterilizations was 40% to 60%. In 1969 The Association for Voluntary Sterilization (AVS) opened the first vasectomy clinic in the U.S. at the Margaret Sanger Center, New York City. During 1970-71 more vasectomy clinics were established around the country. The medical profession began to provide vasectomy as an office procedure. The peak of the vasectomy movement occurred in 1971 when 6700,000 vasectomies were performed. Newer techniques for female sterilization appeared, minilap and laparotomy, which required less hospitalization and facilitated quicker recovery. It is unrealistic to expect sterilization to become the number 1 method for people who are under 29 or 30. The sterilization boom has peaked, and although the numbers of acceptors has increased every year since the 1960's, the level of growth has reached a plateau.

  7. Performance evaluation of solar water sterilization system

    SciTech Connect

    Saitoh, Takeo; El-Ghetany, H.H.

    1998-07-01

    In most countries, the contaminated water is the major cause of most of the water-born diseases. Solar energy can be used in this field because the inactivation of micro-organisms is done by the ultraviolet solar radiation. A pilot solar system for sterilizing the contaminated water is designed, constructed and tested. The experimental data showed good viability for using solar energy in the sterilization process. A mathematical model of the solar sterilizer is also presented. The governing equations are solved numerically using fourth-order Runge-Kutta method. The effects of environmental conditions (ambient temperature, wind speed and solar radiation) on the solar sterilizer performance are examined. It is found that the system is affected by the ambient temperature, wind speed, ultraviolet solar radiation intensity, level of contamination of water, quantity of water being exposed, contact area between the transparent water container in the solar sterilizer and absorber plate and system geometrical parameters. It is pointed that, for a partial cloud condition, low ambient temperature and high wind speed the thermal efficiency of the solar sterilizer was minimum.

  8. Health technology assessment: Off-site sterilization

    PubMed Central

    Dehnavieh, Reza; Mirshekari, Nadia; Ghasemi, Sara; Goudarzi, Reza; Haghdoost, AliAkbar; Mehrolhassani, Mohammad Hossain; Moshkani, Zahra; Noori Hekmat, Somayeh

    2016-01-01

    Background: Every year millions of dollars are expended to equip and maintain the hospital sterilization centers, and our country is not an exception of this matter. According to this, it is important to use more effective technologies and methods in health system in order to reach more effectiveness and saving in costs. This study was conducted with the aim of evaluating the technology of regional sterilization centers. Methods: This study was done in four steps. At the first step, safety and effectiveness of technology was studied via systematic study of evidence. The next step was done to evaluate the economical aspect of off-site sterilization technology using gathered data from systematic review of the texts which were related to the technology and costs of off-site and in-site hospital sterilization. Third step was conducted to collect experiences of using technology in some selected hospitals around the world. And in the last step different aspects of acceptance and use of this technology in Iran were evaluated. Results: Review of the selected articles indicated that efficacy and effectiveness of this technology is Confirmed. The results also showed that using this method is not economical in Iran. Conclusion: According to the revealed evidences and also cost analysis, due to shortage of necessary substructures and economical aspect, installing the off-site sterilization health technology in hospitals is not possible currently. But this method can be used to provide sterilization services for clinics and outpatients centers. PMID:27390714

  9. Health technology assessment: Off-site sterilization.

    PubMed

    Dehnavieh, Reza; Mirshekari, Nadia; Ghasemi, Sara; Goudarzi, Reza; Haghdoost, AliAkbar; Mehrolhassani, Mohammad Hossain; Moshkani, Zahra; Noori Hekmat, Somayeh

    2016-01-01

    Every year millions of dollars are expended to equip and maintain the hospital sterilization centers, and our country is not an exception of this matter. According to this, it is important to use more effective technologies and methods in health system in order to reach more effectiveness and saving in costs. This study was conducted with the aim of evaluating the technology of regional sterilization centers. This study was done in four steps. At the first step, safety and effectiveness of technology was studied via systematic study of evidence. The next step was done to evaluate the economical aspect of off-site sterilization technology using gathered data from systematic review of the texts which were related to the technology and costs of off-site and in-site hospital sterilization. Third step was conducted to collect experiences of using technology in some selected hospitals around the world. And in the last step different aspects of acceptance and use of this technology in Iran were evaluated. Review of the selected articles indicated that efficacy and effectiveness of this technology is Confirmed. The results also showed that using this method is not economical in Iran. According to the revealed evidences and also cost analysis, due to shortage of necessary substructures and economical aspect, installing the off-site sterilization health technology in hospitals is not possible currently. But this method can be used to provide sterilization services for clinics and outpatients centers.

  10. Evaluation of contemporary female sterilization methods.

    PubMed

    Brenner, W E

    1981-09-01

    Different methods of sterilization were evaluated. Laparoscopic techniques were the most satisfactory because they had lower pelvic and incision infection rates and shorter hospitalization and convalescent times than laparotomy lower pelvic infection rates than culdoscopy and culpotomy. Via laparoscopy, sterilization by coagulation and cutting, spring-loaded clips and bands was an effective, safe method. Mechanical problems with the applicator and optics and decreased visibility resulted in more technical failures and difficulties and more misapplication with the clip applicator. Although the total complication rates were similar with all methods, bleeding from the tubes and wound and pelvic infections were more frequent with silastic-band technique. Long-term complications, such as dysmenorrhea and menometrorrhagia and especially those resulting in hysterectomy after laparoscopy, are infrequent. Pregnancy rates are low after laparoscopic sterilization with coagulation and silastic bands as compared to the clip. Rates of complications with sterilization combined with abortion or delivery are only slightly higher than after abortion without sterilization and much less than the combined complications that would be anticipated from abortion and interval sterilization. To make colpotomy, culdoscopy and minilaparotomy easier and potentially safer, mechanical techniques using the spring-loaded clip and silastic band are being evaluated. Simplified techniques that can be administered via the cervix, such as Quinacrine, may be practical in the future.

  11. Is cosmology compatible with sterile neutrinos?

    SciTech Connect

    Dodelson, Scott; Melchiorri, Alessandro; Slosar, Anze; /Ljubljana U.

    2005-11-01

    By combining data from cosmic microwave background (CMB) experiments (including the recent BOOMERANG-2K2 results), large scale structure (LSS) and Lyman-{alpha} forest observations, we constrain the hypothesis of a fourth, sterile, massive neutrino. For the 3 massless + 1 massive neutrino case we bound the mass of the sterile neutrino to m{sub s} < 0.55eV at 95% c.l.. These results exclude at high significance the sterile neutrino hypothesis as an explanation of the LSND anomaly. We then generalize the analysis to account for active neutrino masses (which tightens the limit to m{sub s} < 0.51eV) and the possibility that the sterile abundance is not thermal. In the latter case, the constraints in the (mass, density) plane are non-trivial. For a mass of > 1eV or < 0.05eV the cosmological energy density in sterile neutrinos is always constrained to be {omega}{sub {nu}} < 0.005 at 95% c.l.. However, for a sterile neutrino mass of {approx} 0.25 eV, {omega}{sub {nu}} can be as large as 0.015.

  12. Choosing a low-temperature sterilization technology.

    PubMed

    1999-11-01

    Low-temperature sterilization technologies are used instead of steam for sterilizing heat-sensitive or moisture-intolerant surgical equipment and supplies. In this Guidance Article, we describe several common alternatives, but we focus specifically on the two that have generated the most interest in recent years: ethylene oxide (EtO) and gas plasma sterilization. Ethylene oxide has been used as a low-temperature sterilization technology since the 1950s. Although EtO can be used safely, exposure to this gas is known to be a health hazard, and the emissions from certain EtO sterilizers are known to pollute the atmosphere. For these reasons, the use of EtO is regulated--more strictly in some regions than in others--and many healthcare facilities have decided to investigate alternative technologies. Gas plasma sterilization emerged in the 1990s as one promising alternative. This method appears to pose fewer health and environmental risks, and it offers faster turnaround times. However, this technology also has some limitations. We describe the advantages and disadvantages of both methods, along with the factors to consider when selecting from among these alternatives, in this Guidance Article.

  13. Production of a sterile species: Quantum kinetics

    SciTech Connect

    Ho, Chiu Man; Boyanovsky, D.; Ho, C.M.

    2007-04-23

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is tau(dec)=2/Gamma(aa), but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Gamma(1)=Gamma(aa)cos^2theta(m); Gamma(2)=Gamma(aa)sin^2theta(m) where Gamma(aa) is the interaction rate of the active species in the absence of mixing and theta(m) the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the"polarization vector" and show their equivalence to those obtained from the quantum master equation and effective action.

  14. Tubal sterilization by lararoscopy. Simplified technique.

    PubMed

    Singh, K B

    1977-02-01

    A method of laparoscopic tubal sterilization which has been proven to be simple, safe, and effective in over 1000 patients is described. General anesthesia has usually been used. After the usual preparations, a Semm uterine probe connected with an 80-100 mm of Hg suction is inserted into the uterus for subsequent manipulation. A Veress needle is inserted and 2-3 liters of carbon dioxide gas insufflated into the abdomen. A trocar and cannula are then inserted through an 8 mm intraumbilical incision. A single-incision technique is used. In obese patients, a suprapubic route may be selected. Body weight over 300 pounds is a contraindication. The 170-degree, 10 mm Palmer-Jacobs operating laparoscope with 5.5 mm fibrooptic bundle is inserted into the cannula. A routine survey of the pelvis is made 1st. The insulated grasping forceps, as active electrode, is then introduced into the operating channel. Once identified, each tube is grasped at 2-5 cm from the cornual end, avoiding prominent blood vessels. Coagulation of a small segment of each tube is done without coagulation of the mesosalpinx. Severing of the tubes is done mechanically by push-pull leverage. Blood loss is minimal. Chances of inadvertent bowel burns are reduced due to short duration of RF current use. To use RF current for cutting or severing tubes may injure blood vessels and extensive tissue damage may lead to flare-up of pelvic inflammatory disease. Subsequent tubal patency tests have not been needed. The separated segments of the tubes are protected from mucosal spread of any endometrial infection. Appropriate tubal reconstruction surgery is favored in selected patients. Tubal specimens removed have usually shown good morphological details.

  15. Electroporation System for Sterilizing Water

    NASA Technical Reports Server (NTRS)

    Schlager, Kenneth J.

    2005-01-01

    A prototype of an electroporation system for sterilizing wastewater or drinking water has been developed. In electroporation, applied electric fields cause transient and/or permanent changes in the porosities of living cells. Electroporation at lower field strengths can be exploited to increase the efficiency of chemical disinfection (as in chlorination). Electroporation at higher field strengths is capable of inactivating and even killing bacteria and other pathogens, without use of chemicals. Hence, electroporation is at least a partial alternative to chlorination. The transient changes that occur in micro-organisms at lower electric-field strengths include significantly increased uptake of ions and molecules. Such increased uptake makes it possible to achieve disinfection at lower doses of chemicals (e.g., chlorine or ozone) than would otherwise be needed. Lower doses translate to lower costs and reduced concentrations of such carcinogenic chemical byproducts as trichloromethane. Higher electric fields cause cell membranes to lose semipermeability and thereby become unable to function as selective osmotic barriers between the cells and the environment. This loss of function is the cause of the cell death at higher electric-field intensities. Experimental evidence does not indicate cell lysis but, rather, combined leaking of cell proteins out of the cells as well as invasion of foreign chemical compounds into the cells. The concept of electroporation is not new: it has been applied in molecular biology and genetic engineering for decades. However, the laboratory-scale electroporators used heretofore have been built around small (400-microliter) cuvettes, partly because the smallness facilitates the generation of electric fields of sufficient magnitude to cause electroporation. Moreover, most laboratory- scale electroporators have been designed for testing static water. In contrast, the treatment cell in the present system is much larger and features a flow

  16. Using high-temperature formaldehyde sterilization as a model for studying gaseous sterilization.

    PubMed

    Mosley, Gregg A

    2008-01-01

    This study uses the high-temperature formaldehyde sterilization system provided by the Harvey Chemiclave, manufactured by Barnstead Thermolyne Corporation (Dubuque, IA), as a model to investigate certain phenomena associated with gaseous chemical sterilization systems. Although formaldehyde sterilization presents some unique and complex system attributes, the current studies provide helpful insights into general sterilization methods by chemicals in the gaseous state. Both population recovery and fraction negative (FN) techniques were used to assay surviving populations from biological indicators of the organism Geobacillus stearothermophilus following exposure to incremental Chemiclave cycles. Models 5500 and 6000 of the Barnstead/Thermolyne Chemiclave were used in the study. Reusable instruments such as scalers, explorers, and various hinged pieces were tested in minimum versus maximum load studies. Population recovery study results demonstrated that lethality rates increase with time throughout the Chemiclave sterilization process and that there are significant variations in lethality according to load location. The population recovery data in conjunction with the FN studies and temperature data confirm that one-half the full-cycle time is not a good estimator of one-half the full-cycle lethality because lethality curves are concave downward and lethality varies by load location. This conclusion can also be applied to other types of gaseous, chemical sterilization such as ethylene oxide. The work outlined in this study was a result of investigations into the parameters affecting formaldehyde chemical vapor sterilization with the Harvey Chemiclave sterilizer. During these studies, it became apparent that results clearly depicted the effects of continued acceleration of the rate of microbial lethality, as well as variations in delivered lethality as a function of position in the sterilizer load. This publication focuses on these observations because they are

  17. Sterilization techniques for biodegradable scaffolds in tissue engineering applications

    PubMed Central

    Dai, Zheng; Ronholm, Jennifer; Tian, Yiping; Sethi, Benu; Cao, Xudong

    2016-01-01

    Biodegradable scaffolds have been extensively studied due to their wide applications in biomaterials and tissue engineering. However, infections associated with in vivo use of these scaffolds by different microbiological contaminants remain to be a significant challenge. This review focuses on different sterilization techniques including heat, chemical, irradiation, and other novel sterilization techniques for various biodegradable scaffolds. Comparisons of these techniques, including their sterilization mechanisms, post-sterilization effects, and sterilization efficiencies, are discussed. PMID:27247758

  18. Method and apparatus for sterilizing and charging batteries

    SciTech Connect

    Linden, H.A.

    1987-02-03

    An apparatus is described for providing at least one sterile, charged battery for use in a sterile field comprising: a container adapted to permit the entrance of a sterilant and to prevent the entrance of contaminants, the container being adapted to house the battery during sterilization and storage. The container has means of charging the battery therein while maintaining the battery in a sterile state.

  19. Thermal Profile of Metallic Beads in a Bead Sterilizer,

    DTIC Science & Technology

    1986-08-01

    another commonly used chairside sterilization method, principally for endodontic instruments. The bead sterilizer consists of a heated chamber containing...sterilization of endodontic instruments. However, several investigators have shown sterilization times ranging from 3 seconds to 14 minutes, are...et.al. The effect of autoclave sterilization on endodontic files. Oral Surg 55(2): 204-207, 1983. 3. Parkes, R. B. and Kolstad, R. A. Effects of

  20. Minimal role for the circumsporozoite protein in the induction of sterile immunity by vaccination with live rodent malaria sporozoites.

    PubMed

    Mauduit, Marjorie; Tewari, Rita; Depinay, Nadya; Kayibanda, Michèle; Lallemand, Eliette; Chavatte, Jean-Marc; Snounou, Georges; Rénia, Laurent; Grüner, Anne Charlotte

    2010-05-01

    Immunization with live Plasmodium sporozoites under chloroquine prophylaxis (Spz plus CQ) induces sterile immunity against sporozoite challenge in rodents and, more importantly, in humans. Full protection is obtained with substantially fewer parasites than with the classic immunization with radiation-attenuated sporozoites. The sterile protection observed comprised a massive reduction in the hepatic parasite load and an additional effect at the blood stage level. Differences in the immune responses induced by the two protocols occur but are as yet little characterized. We have previously demonstrated that in mice immunized with irradiated sporozoites, immune responses against the circumsporozoite protein (CSP), the major component of the sporozoite's surface and the leading malaria vaccine candidate, were not essential for sterile protection. Here, we have employed transgenic Plasmodium berghei parasites in which the endogenous CSP was replaced by that of Plasmodium yoelii, another rodent malaria species, to assess the role of CSP in the sterile protection induced by the Spz-plus-CQ protocol. The data demonstrated that this role was minor because sterile immunity was obtained irrespective of the origin of CSP expressed by the parasites in this model of protection. The immunity was obtained through a single transient exposure of the host to the immunizing parasites (preerythrocytic and erythrocytic), a dose much smaller than that required for immunization with radiation-attenuated sporozoites.

  1. A standardized monitor for the control of ethylene oxide sterilization cycles.

    PubMed Central

    Dadd, A. H.; Stewart, C. M.; Town, M. M.

    1983-01-01

    The resistance of spores of B. subtilis var. niger produced in liquid synthetic medium and exposed to ethylene oxide on a nylon surface, has been shown to the almost identical to that for spores produced on a traditional solidified complex medium with exposure to the sterilant on aluminium foil. The use of short lengths of nylon tube as carriers allowed easy production and handling, with self-protection of the spore-bearing surface. Addition of a dye provided visual evidence of inoculation without affecting resistance to ethylene oxide. Such a monitor is suitable for use as a standardized biological challenge in routine ethylene oxide sterilization cycles. PMID:6411808

  2. Anesthesia for outpatient female sterilization.

    PubMed

    Fishburne, J I

    1983-04-01

    This issue of the Bulletin deals with the principles of anesthesia for outpatient female sterilization with emphasis on techniques for laparoscopy and minilaparotomy. General anesthesia techniques provide analgesia, amnesia, and muscle relaxation and are particularly useful for managing the anxious patient. Disadvantages include increased expense, need for specialized equipment, and highly trained personnel, and delayed recovery. Complications, though relatively rare, can be life-threatening and include aspiration of stomach contents, hypoxia, hypercarbia, hypotension, hypertension, cardiac arrhythmias, cardiorespiratory arrest, and death. There is no single preferred technique of general anesthesia, athough most anesthetists employ methods that allow rapid recovery of faculties, enabling the patient to be discharged soon after surgery. To accomplish this end, light anesthesia with sodium thiopental induction and nitrous oxide maintenance is often used. Short duration muscle relaxation with an agent such as succinylcholine supplements this technique. Other techniques include light anesthesia with inhalational anesthetic agents and the use of intravenous ketamine. Local anesthesia augmented by systemic and/or inhalational analgesia is supplanting general anesthesia techniques for laparoscopy in many locales. This approach is also particularly well-suited for minilaparotomy in developing countries, where it has achieved its greatest popularity. The local technique carries with it reduced morbidity and mortality but may not entirely relieve discomfort. The primary danger of local anesthesia is respiratory depression due to excessive narcosis and sedation. The operator must be alert to the action of the drugs and should always use the minimal effective dose. Although toxicity due to overdosage with local anesthetic drugs is occasionally experienced, allergic reactions to the amide-linkage drugs such as lidocaine or bupivacaine are exceedingly rare. For outpatient

  3. Sterilization Performance and Material Compatibility of Sterilizer for Dental Instruments using RF Oxygen Plasma

    NASA Astrophysics Data System (ADS)

    Sakai, Yasuhiro; Liu, Zhen; Hayashi, Nobuya; Goto, Masaaki

    2015-09-01

    The sterilization performance and material compatibility of low-pressure RF plasma sterilization method for dental instruments were investigated. RF electrode used in this experiment has been optimized for sterilization of dental instruments. The vial-type biological indicator (BI) simulating tiny space of dental instrument was used for evaluation of the sterilization performance. The pressure in the stainless chamber was fixed at 60 Pa. Sterilization of BI was achieved in shortest time 40 min at 80 W, and the sterilization effect was confirmed using three BIs. Light emission spectra of oxygen plasma indicated that production of atomic oxygen and excited oxygen molecule are maximum at pressure of 20 Pa and 200 Pa, respectively. Sterilization results of BIs indicated that successful rate increases with the oxygen pressure towards 200 Pa. Therefore, the excited oxygen molecule is deduced to be a major factor of the sterilization of BI. Surface morphology of dental instruments such as diamond bar was evaluated using scanning electron microscope (SEM). The deterioration of fine crystals of diamond bar has not observed after the plasma irradiation for 120 min with RF input power was 60W and pressure was 200 Pa.

  4. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America

    PubMed Central

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Introduction Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Methods Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. Results A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35–13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. Conclusions The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker

  5. Revisiting cosmological bounds on sterile neutrinos

    SciTech Connect

    Vincent, Aaron C.; Martínez, Enrique Fernández; Lattanzi, Massimiliano E-mail: enrique.fernandez-martinez@uam.es E-mail: omena@ific.uv.es

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  6. Mercury release during autoclave sterilization of amalgam.

    PubMed

    Parsell, D E; Karns, L; Buchanan, W T; Johnson, R B

    1996-05-01

    Natural teeth are an invaluable teaching tool for preclinical instruction in operative dentistry and endodontic techniques. Cavity preparation in teeth containing amalgam restorations is a realistic simulation of an often experienced clinical situation. As various pathogens are contained in saliva, teeth must be disinfected before use by students. The purpose of this study is to indirectly evaluate whether mercury vapor is released from amalgam restorations in such teeth during steam autoclave sterilization. Mercury vapor detection, sample mass changes and x-ray fluorescence data were collected from experimental steam autoclave sterilization of amalgam samples sealed in autoclave bags. All of the data showed evidence of mercury vapor generation coincident to steam autoclave sterilization. Mercury vapor levels within the room where amalgam was exposed to steam autoclave sterilization reached levels that constitute an unnecessary health risk to dental personnel. The volume of amalgam tested simulated that contained in 175 amalgam restored teeth. Initial venting of the autoclave chamber produced mercury vapor concentrations significantly in excess of OSHA vapor concentration ceiling levels. Thus, the use of a steam autoclave for sterilization of amalgam containing teeth for use in preclinical laboratory exercises may be harmful to personnel involved.

  7. Is cosmology compatible with sterile neutrinos?

    PubMed

    Dodelson, Scott; Melchiorri, Alessandro; Slosar, Anze

    2006-07-28

    By combining data from cosmic microwave background experiments (including the recent WMAP third year results), large scale structure, and Lyman-alpha forest observations, we constrain the hypothesis of a fourth, sterile, massive neutrino. For the 3 massless+1 massive neutrino case, we bound the mass of the sterile neutrino to ms<0.26 eV (0.44 eV) at 95% (99.9%) C.L., which excludes at high significance the sterile neutrino hypothesis as an explanation of the LSND anomaly. We generalize the analysis to account for active neutrino masses and the possibility that the sterile abundance is not thermal. In the latter case, the contraints in the plane are nontrivial. For a mass of >1 or <0.05 eV, the cosmological energy density in sterile neutrinos is always constrained to be omeganu<0.003 at 95% C.L., but for a mass of approximately 0.25 eV, omeganu can be as large as 0.01.

  8. Sterilization of instruments in solar ovens.

    PubMed

    Jørgensen, A F; Nøhr, K; Boisen, F; Nøhr, J

    2002-01-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem as chemical methods can no longer be recommended and fuel wood is becoming increasingly scarce. It seems obvious, therefore, to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. It was tested by physical, chemical and microbiological methods and, after successful testing, installed in a rural clinic. The oven was able to generate temperatures above 180 degrees C. On days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization. The chemical indicators, Browne's tubes type 3 and 5, also changed colour. It was difficult to reach the right value for the sterilization effect during months with a low sun position. A moveable oven, or two ovens, must be installed to solve this problem. The solar oven has proven to be a realistic method for the sterilization of instruments. The solar oven is easy to make and use. It saves fuel and can be used in most tropical areas.

  9. Immediate use steam sterilization: it's all about the process.

    PubMed

    Nania, Paula

    2013-07-01

    Proper reprocessing of surgical instrumentation assists in infection prevention efforts. Immediate use steam sterilization, previously known as flash sterilization, is an effective method of sterilization if it is performed according to manufacturers' validated instructions. Items that undergo immediate use steam sterilization are subject to the same cleaning and decontamination requirements that apply to preparing items for terminal sterilization, and manufacturers' instructions for use must be strictly followed. In 2009, The Joint Commission revised its position statement on flash sterilization and emphasized that three critical steps of reprocessing must be followed to ensure sterility (ie, cleaning and decontamination, sterilization, aseptic transfer) and that complete documentation must be available for each immediate use steam sterilization cycle so that the device is traceable to the patient if problems arise. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  10. Inductively-Coupled RF Powered O2 Plasma as a Sterilization Source

    NASA Technical Reports Server (NTRS)

    Sharma, S. P.; Rao, M. V. V. S.; Cruden, B. A.; Meyyappan, M.; Mogul, R.; Khare, B.; Chan, S. L.; Arnold, James O. (Technical Monitor)

    2001-01-01

    Low-temperature or cold plasmas have been shown to be effective for the sterilization of sensitive medical devices and electronic equipment. Low-temperature plasma sterilization procedures possess certain advantages over other protocols such as ethylene oxide, gamma radiation, and heat due to the use of inexpensive reagents, the insignificant environmental impacts and the low energy requirements. In addition, plasmas may also be more efficacious in the removal of robust microorganisms due to their higher chemical reactivity. Together, these attributes render cold plasma sterilization as ideal for the surface decontamination requirements for NASA Planetary Protection. Hence, the work described in this study involves the construction, characterization, and application of an inductively-coupled, RF powered oxygen (O2) plasma.

  11. Radiation sterilization of tissue allografts: A review

    PubMed Central

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-01-01

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts. PMID:27158422

  12. Light sterile neutrinos in the early universe

    SciTech Connect

    Lunardini, Cecilia

    2014-06-24

    Cosmological and terrestrial data suggests the number of light neutrinos may be greater than 3, motivating a careful reexamination of cosmological bounds on extra light species. Big bang nucleosynthesis constrains the number of relativistic neutrino species present during nucleosynthesis, N{sub eff}{sup BBN}, while measurements of the cosmic microwave background (CMB) angular power spectrum constrain the effective energy density in relativistic neutrinos at the time of matter-radiation equality, N{sub eff}{sup CMB}. We review a scenario with two sterile neutrinos and explore whether partial thermalization of the sterile states can ease the tension between cosmological constraints on N{sub eff}{sup BBN} and terrestrial data. We conclude that, still, two additional light sterile neutrinos species cannot fit all the data at the 95% confidence level.

  13. Radiation sterilization of tissue allografts: A review.

    PubMed

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-04-28

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts.

  14. Female sterilization by Falope ring ligation.

    PubMed Central

    Lalonde, A. B.

    1982-01-01

    Sterilization with the Falope Ring may be performed by means of laparoscopy of the minilaparotomy. This technique avoids the potential hazards of electrocoagulation, such as intestinal burns. Among the 825 cases reported in this paper there was only one serious complication, an ectopic pregnancy. One other patient had an undetected early pregnancy at the time of sterilization. Two patients became pregnant 4 and 42 month after the procedure. In most cases a diagnostic dilatation and curettage was done before hand. Pathological study of the fallopian tubes of one patient 28 days after the ring was applied revealed complete occlusion of the buckled segment of each tube. Falope Ring sterilization is simple, effective and safe, and the rate of subsequent pregnancy is lower than with conventional burning or clipping techniques. Images FIG. 7 FIG. 8 PMID:7059889

  15. Sterilization and disinfection in the physician's office.

    PubMed Central

    Drummond, D C; Skidmore, A G

    1991-01-01

    OBJECTIVE: To review the principles and practice of sterilization and disinfection of medical instruments in the office setting. DATA SOURCES: Searches of MEDLINE for articles published from 1980 to 1990 on disinfection, sterilization, cross infection, surgical instruments and iatrogenic disease, bibliographies, standard texts and reference material located in a central processing department. STUDY SELECTION: We reviewed surveys of decontamination practices in physicians' offices, reviews of current recommendations for office decontamination procedures, case reports of cross infection in offices and much of the standard reference material on decontamination theory and practice. DATA SYNTHESIS: There have been few surveys of physicians' decontamination practices and few case reports of cross infection. Office practitioners have little access to practical information on sterilization and disinfection. CONCLUSION: The increasing threat of cross infection from medical instruments calls for greater knowledge about decontamination. We have adapted material from various sources and offer a primer on the subject. PMID:1913427

  16. Biological Sterilization of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Albert, F. G.; Combie, J.; Bodnar, R. J.; Hamilton, V. E.; Jolliff, B. L.; Kuebler, K.; Wang, A.; Lindstrom, D. J.; Morris, P. A.

    1999-01-01

    Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

  17. Biological Sterilization of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Albert, F. G.; Combie, J.; Bodnar, R. J.; Hamilton, V. E.; Jolliff, B. L.; Kuebler, K.; Wang, A.; Lindstrom, D. J.; Morris, P. A.

    1999-01-01

    Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

  18. Decontamination formulations for disinfection and sterilization

    DOEpatents

    Tucker, Mark D.; Engler, Daniel E.

    2007-09-18

    Aqueous decontamination formulations that neutralize biological pathogens for disinfection and sterilization applications. Examples of suitable applications include disinfection of food processing equipment, disinfection of areas containing livestock, mold remediation, sterilization of medical instruments and direct disinfection of food surfaces, such as beef carcasses. The formulations include at least one reactive compound, bleaching activator, inorganic base, and water. The formulations can be packaged as a two-part kit system, and can have a pH value in the range of 7-8.

  19. [Treatment of anovulatory cycle induced sterility].

    PubMed

    Botella Llusia, J

    1983-03-01

    Of all the clinical aspects of human sterility, the anovulatory cycle is undoubtedly 1 that has produced the widest range of therapuetic successes. While in other fields progress has been very slow (male sterility or tubal obstruction), ovarian pharmacoendocrinology has shown several advances over recent years. This progress is due partly to new chemicals such as urinary menopausal gonadotropins, LH-RH, and their analogues Clomiphene and Bromocriptine. Contributing further to these good results is a greater knowledge of the etiology of anovulation and a more accurate selection of cases for treatment.

  20. Sterile infiltrates after cross-linking.

    PubMed

    García de Oteyza, G; Álvarez de Toledo, J

    2017-09-01

    A 20 year-old woman presented with an asymmetric bilateral keratoconus. Cross-linking of the right eye was performed due of its topographic and pachymetric conditions. Three days after the procedure, the patient presented with some corneal infiltrates that where classified as sterile. Cross-linking is known for its efficacy and safety. Nevertheless, there can be complications. Sterile infiltrates have already been described, although their aetiology is still not clear. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Microbiological Aspects of Ethylene Oxide Sterilization

    PubMed Central

    Kereluk, K.; Gammon, R. A.; Lloyd, R. S.

    1970-01-01

    A specially built thermochemical death-rate apparatus is described which can be used to determine the resistance of microorganisms to ethylene oxide under controlled conditions. The apparatus was designed to provide instantaneous exposure of microorganisms to ethylene oxide and to eliminate variables that could result in errors when death kinetic reaction rates are calculated. The apparatus is used to obtain ethylene oxide resistance data which are useful in evaluating and developing sterilizing cycles for materials with known bacterial concentrations, as well as for calculating probability factors on which a given test condition can be expected to provide sterilization. PMID:4984364

  2. Solar neutrino detectors as sterile neutrino hunters

    NASA Astrophysics Data System (ADS)

    Pallavicini, Marco; Borexino-SOX Collaboration; Agostini, M.; Altenmüller, K.; Appel, S.; Atroshchenko, V.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; Cloué, O.; Cribier, M.; D’Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Durero, M.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Gschwender, M.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jany, A.; Jedrzejczak, K.; Jeschke, D.; Jonquères, N.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Ortica, F.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Reinert, Y.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Veyssière, C.; Vishneva, A.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2017-09-01

    The large size and the very low radioactive background of solar neutrino detectors such as Borexino at the Gran Sasso Laboratory in Italy offer a unique opportunity to probe the existence of neutrino oscillations into new sterile components by means of carefully designed and well calibrated anti-neutrino and neutrino artificial sources. In this paper we briefly summarise the key elements of the SOX experiment, a program for the search of sterile neutrinos (and other short distance effects) by means of a 144Ce-144Pr anti-neutrino source and, possibly in the medium term future, with a 51Cr neutrino source.

  3. Nursing concerns and hospital product sterilization.

    PubMed

    Rock, R B; Anderson, N A

    1981-01-01

    Nurses and other health care professionals must be aware of the rationale and methodology for in-hospital health care product standardization, including consideration of the hospital standardization committee composition, pilot-study prerequisites, and general evaluation criteria. They must be familiar with the techniques of product sterilization, their effectiveness, and the materials required to maintain sterile product shelf-life until a product is used. Hospital standardization committees can assist in the product-use decisionmaking process. Product evaluation criteria should include considerations pertaining to cost, quality, service, and comparison to similar products.

  4. Modeling the suppression of sea lamprey populations by the release of sterile males or sterile females

    USGS Publications Warehouse

    Klassen, Waldemar; Adams, Jean V.; Twohey, Michael B.

    2004-01-01

    The suppressive effects of trapping adult sea lampreys, Petromyzon marinus Linnaeus, and releasing sterile males (SMRT) or females (SFRT) into a closed system were expressed in deterministic models. Suppression was modeled as a function of the proportion of the population removed by trapping, the number of sterile animals released, the reproductive rate and sex ratio of the population, and (for the SFRT) the rate of polygyny. Releasing sterile males reduced populations more quickly than did the release of sterile females. For a population in which 30% are trapped, sterile animals are initially released at ratio of 10 sterile to 1 fertile animal, 5 adult progeny are produced per fertile mating, 60% are male, and males mate with an average of 1.65 females, the initial population is reduced 87% by SMRT and 68% by SFRT in one generation. The extent of suppression achieved is most sensitive to changes in the initial sterile release ratio. Given the current status of sea lamprey populations and trapping operations in the Great Lakes, the sterile-male-release technique has the best chance for success on a lake-wide basis if implemented in Lake Michigan. The effectiveness of the sterile-female-release technique should be investigated in a controlled study. Advancing trapping technology should be a high priority in the near term, and artificial rearing of sea lampreys to the adult stage should be a high priority in the long term. The diligent pursuit of sea lamprey suppression over a period of several decades can be expected to yield great benefits.

  5. Nurses and the sterilization experiments of Auschwitz: a postmodernist perspective.

    PubMed

    Benedict, Susan; Georges, Jane M

    2006-12-01

    The medical experiments conducted on non-consenting prisoners of Nazi concentration camps during World War II necessitated the codification of principles to protect human subjects of research. Auschwitz was the largest and one of the most infamous of the camps and the site of numerous 'medical' experiments. This historical study uses primary source documents obtained from archives in England and Germany to describe one type of experiment carried out at Auschwitz - the sterilization experiments. The purpose of these experiments was to perfect a technique in which non-Aryans could be prevented from reproducing while still being able to work as slave laborers. These narratives regarding the sterilization experiments at Auschwitz are remarkable in that they contain previously undocumented information regarding the voluntary and involuntary involvement of nurses. Following these narratives, a discussion of ethics in relation to the Holocaust is presented with a specific focus on the work of Agamben. Implications of the Auschwitz narratives for the application of codes of ethical principles and contemporary nursing are discussed from a postmodernist perspective.

  6. Effects of Sterilizing Agents on Microorganisms

    DTIC Science & Technology

    1963-03-01

    vided either is valid at high temperatures. (4) Radiation La Bree, T. R., Fields, M. L., Desrosier, N. W. sterilization may become useful in the beverage ...e’sters, nisin , (’thhvln oxide, diepoxvbutane, (ight chemical formulations upon microbial numbers in hydrogen peroxide, formaldehyde

  7. Male sterility and hybrid seed production

    USDA-ARS?s Scientific Manuscript database

    Sexual reproduction in angiosperms is a complex process that includes a portion of the vegetative generation and all of the sexual generation. Coordination of both female and male reproduction ontogenies must occur. An abnormality anywhere in this process may lead to sterility. Genetic (nuclear) and...

  8. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) The sterility test must be appropriate to the material being tested such that the material does not... inhibitors, neutralizers, and preservatives, if present, in the tested material; (5) For a culture-based test method, the volume of test material that results in a dilution of the product that is not...

  9. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) The sterility test must be appropriate to the material being tested such that the material does not... inhibitors, neutralizers, and preservatives, if present, in the tested material; (5) For a culture-based test method, the volume of test material that results in a dilution of the product that is not...

  10. Molecular analysis of cytoplasmic male sterility

    SciTech Connect

    Hanson, M.R.

    1990-01-01

    The ultimate aims of the project are to understand the molecular mechanism of the disruption in pollen development which occurs in cytoplasmic male sterile plants and to understand the control of respiratory energy flow in the higher plant cell. A mitochondrial locus termed S-pcf segregates with sterility and with an alteration in respiration in Petunia. This cloned locus contains three genes, an abnormal fused gene termed pcf, a gene for a subunit of an NADH dehydrogenase complex, and a small ribosomal subunit protein. The pcf gene is comprised of partial sequences of ATPase subunit 9, cytochrome oxidase subunit II, and an unidentified reading frame. Components of the S-Pcf locus will be introduced into the nuclear of a fertile genotype under the control of appropriate regulatory signals, and polypeptide products of introduced genes will be directed to the mitochondrion with a transit peptide. By examining transgenic plants, we can determine what elements of the locus are critical for altered respiration or sterility. Such knowledge could explain how mitochondrial DNA affects pollen development in the large number of plant species which exhibit the agronomically important trait of male sterility. 10 refs., 3 figs.

  11. Advances in Sterilization and Decontamination: a Survey

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Recent technical advances made in the field of sterilization and decontamination and their applicability to private and commercial interests are discussed. Government-sponsored programs by NASA produced the bulk of material presented in this survey. The summary of past and current research discussed is detailed to enhance an effective transfer of technology from NASA to potential users.

  12. The Decision for Male versus Female Sterilization.

    ERIC Educational Resources Information Center

    Clark, Margaret Pruitt; And Others

    1979-01-01

    The increasing popularity of sterilization underscores the need for knowledge about couples choosing male and female procedures. This research delineates four sets of variables that may be important for the decision and examines their relationship with the choice of male or female procedure among a sample of married couples. (Author)

  13. Sterilization: A Conference and a Report.

    ERIC Educational Resources Information Center

    Dillingham, Brint

    1978-01-01

    This article continues a series on Native American sterilization, based on a conference of the National Council of Churches' Interreligious Foundation for Community Organization (IFCO). Also included are an article and a report by the American Civil Liberties Union. (Author/RTS)

  14. Heat sterilization times of five hardwood species

    Treesearch

    William T. Simpson; Xiping Wang; John W. Forsman; John R. Erickson

    2005-01-01

    Heat sterilization of lumber, timbers, and pallets is currently used to kill insects, thus preventing their transfer between countries in international trade. An important factor in this treatment is the time required for the center of any wood configuration to reach the temperature necessary to kill the insect. This study explored the effect of size (1-, 1.5-, and 2.0...

  15. New technology for sterilization and disinfection.

    PubMed

    Nyström, B

    1991-09-16

    Sterilization with low temperature steam and formaldehyde is a well-known process in many European countries, but little known in the United States. It sterilizes reliably and reproducibly at temperatures greater than or equal to 65 degrees C. With a well-designed cycle, it leaves residues of formaldehyde on sterilized items below 5 micrograms/cm2, measured on a standard filter paper. Formaldehyde levels in air near the autoclave are well below official exposure limits, if at all measurable. Occurrence of late growers in bioindicators, and penetration of the sterilizing media into long narrow lumina, should be validated for new processes. Automated cleaning and disinfection in closed washer-disinfectors and flushing disinfectors are likewise processes relatively little known in the United States. Disinfection is achieved by a final rinse with hot water or steam. Washer-disinfectors are used for surgical instruments, nondisposable anesthesia and other equipment, flushing disinfectors for nondisposable bedpans, wash-bowls, urinals, and similar equipment. They clean well, washer-disinfectors excellently so, and disinfect reliably. With the use of such equipment in wards, surgical departments, and other areas, reliance on chemical germicides can be dramatically reduced and disposables can be replaced by disinfectable nondisposables.

  16. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... sterility test of the product. Fluid Thioglycollate Medium shall be stored in the dark at room temperature... for Whole Blood, Cryoprecipitated AHF, Platelets, Red Blood Cells, Plasma, Source Plasma, Smallpox Vaccine, Reagent Red Blood Cells, Anti-Human Globulin, or Blood Grouping Reagent. (ii) Where a...

  17. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... sterility test of the product. Fluid Thioglycollate Medium shall be stored in the dark at room temperature... for Whole Blood, Cryoprecipitated AHF, Platelets, Red Blood Cells, Plasma, Source Plasma, Smallpox Vaccine, Reagent Red Blood Cells, Anti-Human Globulin, or Blood Grouping Reagent. (ii) Where a...

  18. Sterile Neutrino Experiments I: Accelerator-based

    NASA Astrophysics Data System (ADS)

    Toups, Matthew

    2017-01-01

    The Standard Model is the theory that describes the fundamental constituents of matter and their interactions. Despite its great success, there still exists evidence for a wide range of phenomena, which lie outside the framework of the Standard Model. Among these, neutrino flavor oscillations hold great promise to bring insight to the field towards a theory that transcends the Standard Model. The discovery of light, sterile neutrinos that mix with the three active neutrino flavors and modify the standard three-neutrino oscillation probabilities in vacuum and matter would be a major breakthrough for the field and contribute to our overall understanding of neutrino mass and mixing. Current indications for light sterile neutrinos come from a variety of experiments reporting anomalies. The accelerator-based LSND and MiniBooNE experiments, for example, reported an excess of electron-type neutrinos over short baselines, which if interpreted as due to νμ ->νe (or νμ ->νe) oscillations, would imply the existence of a fourth light neutrino mass state. On the other hand, null results from other accelerator-based neutrino oscillation experiments searching for sterile neutrinos have put constraints on the possible existence of these particles. This talk will review the accelerator-based searches for light, sterile neutrinos as well as the prospects for confirming or refuting their existence in the coming years.

  19. Surface sterilization of hybrid poplar cuttings

    Treesearch

    Alma M. Waterman

    1954-01-01

    Fungus diseases of hybrid poplars may be spread by spores that lodge in the resinous coating of buds of dormant cuttings, and in the lenticels. Surface sterilization by dipping the cuttings in fungicides was tested to determine whether such treatment would prevent the germination of spores of the canker-producing fungi Septoria musiva and Dothichiza populea and the...

  20. [Laparoscopic sterilization using tubal rings and clips].

    PubMed

    Borko, E; Breznik, R; Ivanisević, V; Herzmansky, M

    1980-01-01

    From 1978 to April 1980, 36 laparoscopic sterilization procedures were completed at the Gynecological Department in Maribor. For tubal occlusion in 16 cases Tupla clips and in 20 cases the Tubal Falope ring were used. It appears that the incidence of complications and other technical difficulties is somewhat more frequent with clips. There have been no pregnancies in all these cases.

  1. [Anesthesia for laparoscopy in sterile patients].

    PubMed

    Schönrath, B; Borgwardt, D; Langanke, D; Alexander, H; Baier, D; Haake, K W

    1990-01-01

    During 5 years 382 laparoscopies were carried through in female patients with sterility in different kinds of anaesthesia (Intubation anaesthesia, spinal anaesthesia, and i.v. anaesthesia). We found the most advantageous results in the cases of i.v. anaesthesia with Ketamin and Diazepam.

  2. Perspectives: Eugenics and Sterilization in the Heartland.

    ERIC Educational Resources Information Center

    Wehmeyer, Michael L.

    2003-01-01

    Noting the Governor of Virginia's recent apology for his state's participation in eugenics, this article reviews the history of the sterilization of people with epilepsy and mental retardation in several states, and the importance of the Buck v. Bell (1927) Supreme Court decision in the promotion of eugenics. (Contains references.) (CR)

  3. Compulsory sterilization. (Letter to the editor).

    PubMed

    Nixon, R K

    1972-10-16

    Angela R. Holder's conclusion (221: 229, 1972) that a decline in forced sterilization cases exists because "any system of compulsory sterilization is too near naziism to be acceptable in a democratic society" ignores present realities. At no time in American history has there been greater acceptance of the idea that human procreation must be regulated by coercive means. Many leaders of the movement for population control, for example, openly advocate mandatory sterilization, abortion, and birth control as part of their crash program for population stabilization. Simultaneously, a growing number of those concerned with genetic "quality" demand that individual rights be subordinated or destroyed for the good of society and the species. Meanwhile, the increasing minimization of the enormous complexities of the abortion issue to a morally and medically neutral therapeutic procedure, threatens to make abortions, as well as sterilization, innocu ous public health measures that could be forced on society if circumstan ces dictate. Moreover, as the public is conditioned to believe that these measures lack ethical ramifications, the day is hastened when they can be imposed without significant opposition. full text

  4. Steam sterilization of air turbine dental handpieces.

    PubMed

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem.

  5. Sterilization of Microorganisms by Ozone and Ultrasound

    NASA Astrophysics Data System (ADS)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  6. Perspectives: Eugenics and Sterilization in the Heartland.

    ERIC Educational Resources Information Center

    Wehmeyer, Michael L.

    2003-01-01

    Noting the Governor of Virginia's recent apology for his state's participation in eugenics, this article reviews the history of the sterilization of people with epilepsy and mental retardation in several states, and the importance of the Buck v. Bell (1927) Supreme Court decision in the promotion of eugenics. (Contains references.) (CR)

  7. Sterile soil from Antarctica: organic analysis.

    PubMed

    Horowitz, N H; Bauman, A J; Cameron, R E; Geiger, P J; Hubbard, J S; Shulman, G P; Simmonds, P G; Westberg, K

    1969-05-30

    Soils from the dry-valley region of Antarctica can be sterile by the usual microbiological criteria and yet contain significant amounts of organic carbon. Examination of one such soil shows that the organic material is finely divided anthracite coal. These findings have significant implications for the biological exploration of Mars.

  8. Light sterile neutrinos after BICEP-2

    SciTech Connect

    Archidiacono, Maria; Hannestad, Steen; Fornengo, Nicolao; Gariazzo, Stefano; Giunti, Carlo; Laveder, Marco E-mail: fornengo@to.infn.it E-mail: giunti@to.infn.it E-mail: marco.laveder@pd.infn.it

    2014-06-01

    The recent discovery of B-modes in the polarization pattern of the Cosmic Microwave Background by the BICEP2 experiment has important implications for neutrino physics. We revisit cosmological bounds on light sterile neutrinos and show that they are compatible with all current cosmological data provided that the mass is relatively low. Using CMB data, including BICEP-2, we find an upper bound of m{sub s} < 0.85 eV (2σ Confidence Level). This bound is strengthened to 0.48 eV when HST measurements of H{sub 0} are included. However, the inclusion of SZ cluster data from the Planck mission and weak gravitational measurements from the CFHTLenS project favours a non-zero sterile neutrino mass of 0.44{sup +0.11}{sub −0.16} eV. Short baseline neutrino oscillations, on the other hand, indicate a new mass state around 1.2 eV. This mass is highly incompatible with cosmological data if the sterile neutrino is fully thermalised (Δχ{sup 2} > 10). However, if the sterile neutrino only partly thermalises it can be compatible with all current data, both cosmological and terrestrial.

  9. SPAN C - Terminal sterilization process analysis program

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Computer program, SPAN-C, measures the dry heat thermal sterilization process applied to a planetary capsule and calculates the time required for heat application, steady state conditions, and cooling. The program is based on the logarithmic survival of micro-organisms. Temperature profiles must be input on cards.

  10. SPAN - Terminal sterilization process analysis program

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Computer program, SPAN, measures the dry heat thermal sterilization process applied to a planetary capsule and calculates the time required for heat application, steady state conditions, and cooling. The program is based on the logarithmic survival of micro-organisms. Temperature profiles must be input on tape.

  11. System for sterilizing objects. [cleaning space vehicle systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Wright, E. E., Jr.; Moyers, C. V. (Inventor)

    1981-01-01

    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

  12. Red oak borers become sterile when reared under continuous light

    Treesearch

    Jimmy R. Galford

    1975-01-01

    Red oak borers, Enaphalodes rufulus (Haldeman), reared under continuous light for 12 weeks became sterile. Sterility is thought to have been caused by light destroying vitamins essential for fertility

  13. Validation of a microwave sterilizer for injection ampules.

    PubMed

    Sasaki, K; Honda, W; Ohsawa, S; Miyake, Y; Kawashima, Y

    1999-01-01

    A program for validating the microwave sterilizer, which is a new type of sterilizer, was established and implemented. This program includes the following tests specific to microwave sterilizers: the internal pressure strength of ampules, the acceptable range of sterilizing temperature, performance and calibration of the infrared thermometer and the plane blackbody, maintaining of sterilizing temperature, the processing speed (sterilizing time), the unacceptable ampules selection mechanism, microwave leaks, and a microbiological challenge test of the ampule head space using a biological indicator. Injectable preparations of mecobalamin and diprophylline were used as models for validation of the microwave sterilizer. The bioburden approach was used for injectable mecobalamin preparation, and the over-kill approach was used for injectable diprophylline preparation. The basis for practical use of this microwave sterilizer has been confirmed by the establishment and implementation of this validation program.

  14. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization.

  15. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    NASA Astrophysics Data System (ADS)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  16. Device and Container for Reheating and Sterilization

    NASA Technical Reports Server (NTRS)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  17. Orthodontic instrument sterilization with microwave irradiation

    PubMed Central

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-01-01

    Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686

  18. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently incapable...

  19. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently incapable...

  20. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently incapable...

  1. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently incapable...

  2. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently incapable...

  3. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Boiling water sterilizer. 872.6710 Section 872.6710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an...

  4. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  5. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  6. The Coercive Sterilization of Aboriginal Women in Canada

    ERIC Educational Resources Information Center

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  7. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  8. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  9. Committee opinion no. 530: access to postpartum sterilization.

    PubMed

    2012-07-01

    Postpartum tubal sterilization is one of the safest and most effective methods of contraception. Women who desire this type of sterilization typically undergo thorough counseling and informed consent during prenatal care and reiterate their desire for postpartum sterilization at the time of their hospital admission. Not all women who desire postpartum sterilization actually undergo the surgical procedure, and women with unfulfilled requests for postpartum sterilization have a high rate of repeat pregnancy (approaching 50%) within the following year. Potentially correctable barriers to obtaining postpartum sterilization include patient and health care provider factors, as well as hospital and health care system issues. Given the consequences of a missed procedure and the limited time frame in which it may be performed, postpartum sterilization should be considered an urgent surgical procedure. In addition, women with government insurance face barriers to sterilization procedures based on cumbersome consent requirements. The differences in the requirements surrounding consent for sterilization procedures based on the type of insurance a patient has must be addressed in order to establish fair and equitable access to sterilization procedures for all women. Policies and procedures that remove barriers to and increase efficiency in performing postpartum sterilization could reduce cancellations of the procedure. Improving consistency in accomplishing desired postpartum sterilization is an important strategy to reduce high rates of unintended pregnancy in the United States.

  10. MSI's unique, multi-functional contract sterilization facility

    NASA Astrophysics Data System (ADS)

    Morganstern, Kennard H.

    Medical Sterilization Inc. is a unique company supplying sterilization services to regional hospitals in the New York area and also providing contract sterilization and radiation processing services to industry. The evolution from a concept to an operational entity is reviewed in this report.

  11. The Coercive Sterilization of Aboriginal Women in Canada

    ERIC Educational Resources Information Center

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  12. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  13. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  14. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  15. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  16. Suppression of Pest Lepidoptera by Releasing Partially Sterile Males

    ERIC Educational Resources Information Center

    Knipling. E. F.

    1970-01-01

    Uses population growth models to calculate the theoretical suppression of reproduction achieved by releasing irradiated male moths carrying genetic sterility factors. Shows that releasing partially sterile males should be more effective than releasing fully sterile males. Discusses the costs and advantages of applying this approach to the control…

  17. Suppression of Pest Lepidoptera by Releasing Partially Sterile Males

    ERIC Educational Resources Information Center

    Knipling. E. F.

    1970-01-01

    Uses population growth models to calculate the theoretical suppression of reproduction achieved by releasing irradiated male moths carrying genetic sterility factors. Shows that releasing partially sterile males should be more effective than releasing fully sterile males. Discusses the costs and advantages of applying this approach to the control…

  18. Development of male-sterile lines for breeding hybrid rice

    USDA-ARS?s Scientific Manuscript database

    Rice is a self-pollinated crop that depends on male-sterility for F1 hybrid seed production. As an alternative to accessing existing male-sterile lines from other hybrid breeding programs, the program in Arkansas has created its own novel male-sterile sources. These were developed out of germplasm...

  19. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  20. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  1. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO)...

  2. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO)...

  3. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO)...

  4. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO)...

  5. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO)...

  6. Sterilization project offers model for better care.

    PubMed

    Finger, W R

    1993-08-01

    India's experiences with sterilization indicate that quality of care is an essential feature of appropriate, voluntary family planning services. Good quality of care reduces the problems associated with services and increases client's acceptability and continuation rates. The Center for Excellence in India has established a model that emphasis matching the right method with each client's circumstances. The model first developed standards, which were based on international guidelines and expertise, and then developed and implemented a training program for providers; finally, a quality assurance system was established in order to promote compliance with standards. At present, there is not 100% agreement among international guidelines on standards for sterilization or other methods. In 1992, Family Health International (FHI) published a comparison on 8 major sets of service, delivery, guidelines, and were used around the world; FHI world wide variations in guidelines. A USAID study group is currently reviewing scientific evidence on oral contraceptives, injectables, Norplant, and IUDS. There is difficulty in reaching international consensus and even greater difficulty in changing approaches and policies of specific countries. It is much easier to institute quality of care issues at the beginning of program development or when methods are first introduced. In India, the Centers of Excellence program developed its own national standards on sterilization, and the resulting document is specifically suited to India. The standards emphasize the client's choice and human issues such as counseling and communication. Sterilization reversal, which is not always successful, will be provided, even though sterilization will be promoted as a permanent procedure. 4 regional centers have been set up through medical colleges in Delhi, Calcutta, Bombay and Madras. 12 additional state level centers will be established in the future. Good training was considered an essential part of the

  7. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    PubMed

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Modelling releases of sterile mosquitoes with different strategies.

    PubMed

    Li, Jia; Yuan, Zhiling

    2015-01-01

    To prevent the transmissions of malaria, dengue fever, or other mosquito-borne diseases, one effective weapon is the sterile insect technique in which sterile mosquitoes are released to reduce or eradicate the wild mosquito population. To study the impact of the sterile insect technique on disease transmission, we formulate discrete-time mathematical models, based on difference equations, for the interactive dynamics of the wild and sterile mosquitoes, incorporating different strategies in releasing sterile mosquitoes. We investigate the model dynamics and compare the impact of the different release strategies. Numerical examples are given to demonstrate rich dynamical features of the models.

  9. A double inductively coupled plasma for sterilization of medical devices

    NASA Astrophysics Data System (ADS)

    Halfmann, H.; Bibinov, N.; Wunderlich, J.; Awakowicz, P.

    2007-07-01

    A double inductively coupled low pressure plasma for sterilization of bio-medical materials is introduced. It is developed for homogeneous treatment of three-dimensional objects. The short treatment times and low temperatures allow the sterilization of heat sensitive materials like ultra-high-molecular-weight-polyethylene or polyvinyl chloride. Using a non-toxic atmosphere reduces the total process time in comparision with common methods. Langmuir probe measurements are presented to show the difference between ICP- and CCP-mode discharges, the spatial homogeneity and the influence on the sterilization efficiency. To know more about the sterilization mechanisms optical emission is measured and correlated with sterilization results.

  10. Cationic liposome-DNA complexes (CLDC) adjuvant enhances the immunogenicity and cross-protective efficacy of a pre-pandemic influenza A H5N1 vaccine in mice.

    PubMed

    Dong, Libo; Liu, Feng; Fairman, Jeffery; Hong, David K; Lewis, David B; Monath, Thomas; Warner, John F; Belser, Jessica A; Patel, Jenish; Hancock, Kathy; Katz, Jacqueline M; Lu, Xiuhua

    2012-01-05

    The development of pre-pandemic influenza A H5N1 vaccines that confer both antigen-sparing and cross-clade protection are a high priority given the limited worldwide capacity for influenza vaccine production, and the antigenic and genetic heterogeneity of circulating H5N1 viruses. The inclusion of potent adjuvants in vaccine formulations may achieve both of these aims. Here we show that the addition of JVRS-100, an adjuvant consisting of cationic liposome-DNA complexes (CLDC) to a clade 1-derived H5N1 split vaccine induced significantly higher virus-specific antibody than unadjuvanted formulations, with a >30-fold dose-sparing effect and induction of increased antigen-specific CD4(+) T-cell responses in mice. All mice that received one dose of adjuvanted vaccine and subsequent H5N1 viral challenges exhibited mild illness, lower lung viral titers, undetectable spleen and brain viral titers, and 100% survival after either homologous clade 1 or heterologous clade 2 H5N1 viral challenges, whereas unadjuvanted vaccine recipients showed significantly increased weight loss, viral titers, and mortality. The protective immunity induced by JVRS-100 adjuvanted H5N1 vaccine was shown to last for over one year without significant waning. Thus, JVRS-100 adjuvanted H5N1 vaccine elicited enhanced humoral and T-cell responses, dose-sparing, and cross-clade protection in mice. CLDC holds promise as an adjuvant for human pre-pandemic inactivated H5N1 vaccines.

  11. Application of a Dense Gas Technique for Sterilizing Soft Biomaterials

    PubMed Central

    Karajanagi, Sandeep S.; Yoganathan, Roshan; Mammucari, Raffaella; Park, Hyoungshin; Cox, Julian; Zeitels, Steven M.; Langer, Robert; Foster, Neil R.

    2017-01-01

    Sterilization of soft biomaterials such as hydrogels is challenging because existing methods such as gamma irradiation, steam sterilization, or ethylene oxide sterilization, while effective at achieving high sterility assurance levels (SAL), may compromise their physicochemical properties and biocompatibility. New methods that effectively sterilize soft biomaterials without compromising their properties are therefore required. In this report, a dense-carbon dioxide (CO2)-based technique was used to sterilize soft polyethylene glycol (PEG)-based hydrogels while retaining their structure and physicochemical properties. Conventional sterilization methods such as gamma irradiation and steam sterilization severely compromised the structure of the hydrogels. PEG hydrogels with high water content and low elastic shear modulus (a measure of stiffness) were deliberately inoculated with bacteria and spores and then subjected to dense CO2. The dense CO2-based methods effectively sterilized the hydrogels achieving a SAL of 10−7 without compromising the viscoelastic properties, pH, water-content, and structure of the gels. Furthermore, dense CO2-treated gels were biocompatible and non-toxic when implanted subcutaneously in ferrets. The application of novel dense CO2-based methods to sterilize soft biomaterials has implications in developing safe sterilization methods for soft biomedical implants such as dermal fillers and viscosupplements. PMID:21337339

  12. A search for sterile neutrinos in MINOS

    SciTech Connect

    Osiecki, Thomas Henry

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm$2\\atop{23}$ and θ23 through the disappearance of vμ, MINOS is able to measure vμ → vsterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  13. [Sterile insect technique: targeted control without insecticide].

    PubMed

    Boyer, S

    2012-03-01

    Sterile insect technique (SIT) is a method of disease vector control technique that consists of releasing overwhelming numbers of sterile males. This method provides an environmentally friendly alternative to insecticides. Another advantage of SIT in comparison with other methods is to provide a targeted species-specific approach. In Reunion Island, SIT has been proposed as a basis for developing a viable method of vector control against Aedes albopictus and Anopheles arabiensis. The technique has already been successfully tested on fly and mosquito species for more than 40 years. The CRVOI (Centre de Recherche et de Veille sur les Maladies Emergentes dans l'Océan Indien) is carrying out studies to determine the feasibility of SIT for control of Anopheles arabiensis (vector of malaria) and Aedes albopictus (vector of chikungunya and dengue) on Reunion Island and other islands in the Indian Ocean region.

  14. Daughters mimic sterile neutrinos (almost!) perfectly

    NASA Astrophysics Data System (ADS)

    Hasenkamp, Jasper

    2014-09-01

    Since only recently, cosmological observations are sensitive to hot dark matter (HDM) admixtures with sub-eV mass, mhdmeff < eV, that are not fully-thermalised, Δ Neff < 1. We argue that their almost automatic interpretation as a sterile neutrino species is neither from theoretical nor practical parsimony principles preferred over HDM formed by decay products (daughters) of an out-of-equilibrium particle decay. While daughters mimic sterile neutrinos in Neff and mhdmeff, there are opportunities to assess this possibility in likelihood analyses. Connecting cosmological parameters and moments of momentum distribution functions, we show that—also in the case of mass-degenerate daughters with indistinguishable main physical effects—the mimicry breaks down when the next moment, the skewness, is considered. Predicted differences of order one in the root-mean-squares of absolute momenta are too small for current sensitivities.

  15. Can sterile neutrinos be the dark matter?

    PubMed

    Seljak, Uros; Makarov, Alexey; McDonald, Patrick; Trac, Hy

    2006-11-10

    We use the Ly-alpha forest power spectrum measured by the Sloan Digital Sky Survey and high-resolution spectroscopy observations in combination with cosmic microwave background and galaxy clustering constraints to place limits on a sterile neutrino as a dark matter candidate in the warm dark matter scenario. Such a neutrino would be created in the early Universe through mixing with an active neutrino and would suppress structure on scales smaller than its free-streaming scale. We ran a series of high-resolution hydrodynamic simulations with varying neutrino masses to describe the effect of a sterile neutrino on the Ly-alpha forest power spectrum. We find that the mass limit is m(s) >13 keV at 95% C.L. (9 keV at 99.9%), which is above the upper limit allowed by x-ray constraints, excluding this candidate from being all of the dark matter in this model.

  16. Light Sterile Neutrino Search at Daya Bay

    NASA Astrophysics Data System (ADS)

    Ling, Jiajie; Daya Bay Collaboration

    2014-09-01

    It has been well established through neutrino oscillation that neutrinos have masses and their flavors mix. In 2012, The Daya Bay Reactor Neutrino Experiment discovered that the last unknown neutrino mixing angle θ13 is non-zero. With more than one million reactor antineutrino interactions recorded since December 2011, besides the most precise measurement of sin2 2θ13 , the Daya Bay experiment also has high sensitivity in sterile neutrino search due to its multiple baselines. In this talk, I will discuss the spectral analysis of the light sterile neutrino search in the largely unexplored region of 10-3 eV2 < | Δm2 | < 0 . 3 eV2 at Daya Bay through the electron antineutrino disappearance channel.

  17. Light sterile neutrinos and inflationary freedom

    SciTech Connect

    Gariazzo, S.; Giunti, C.; Laveder, M. E-mail: giunti@to.infn.it

    2015-04-01

    We perform a cosmological analysis in which we allow the primordial power spectrum of scalar perturbations to assume a shape that is different from the usual power-law predicted by the simplest models of cosmological inflation. We parameterize the free primordial power spectrum with a ''piecewise cubic Hermite interpolating polynomial'' (PCHIP). We consider a 3+1 neutrino mixing model with a sterile neutrino having a mass at the eV scale, which can explain the anomalies observed in short-baseline neutrino oscillation experiments. We find that the freedom of the primordial power spectrum allows to reconcile the cosmological data with a fully thermalized sterile neutrino in the early Universe. Moreover, the cosmological analysis gives us some information on the shape of the primordial power spectrum, which presents a feature around the wavenumber k=0.002 Mpc{sup −1}.

  18. Psychosexual adjustment following sterilization: a prospective study on Chinese women.

    PubMed

    Tang, C S; Chung, T K

    1997-02-01

    The present study aimed to identify significant predictors of Chinese women's psychosexual adjustment after sterilization. One hundred fifteen multiparous Chinese women, aged 25-51 years, were interviewed before and after elective laparoscopic or postpartum sterilization. Eight-seven women were also interviewed about their pshychosexual adjustment at 1 year after sterilization. Results showed that the fear of negative evaluation by others, family cohesion and adaptability, and preoperative psychological distress were robust predictors of adverse psychosexual outcome immediately and 1 year after sterilization. There was significant improvement in women's mental health following sterilization, and their sexual adjustment such as coital frequency and sexual satisfaction were not adversely affected at 1 year follow-up. Women with either elective or postpartum sterilization had similar adjustment throughout, except the latter group tended to experience more physical discomfort at 1 year follow-up. About 3.4% of the women experienced regret at 12 months after sterilization.

  19. The sterilization efficacy of reprocessed single use diathermy pencils.

    PubMed

    Batista Neto, Simone; Graziano, Kazuko Uchikawa; Padoveze, Maria Clara; Kawagoe, Júlia Yaeko

    2010-01-01

    In Brazil, single use diathermy pencils (SUDP) are among the most common reused devices. This study assesses the sterilization efficacy of reprocessing SUDP using two cleansing methods (manual or automated), followed by one of three of the low-temperature sterilization methods: Hydrogen Peroxide Plasma (HPP), Ethylene Oxide (ETO) or Low-Temperature Steam Formaldehyde (LTSF). The sample was composed of 360 SUDP after their first use. The probability of sterilization failure was estimated considering the number of positive microbiological results obtained by cultures of the studied devices. The overall sterilization failure probability for SUDP was 0.26. The sterilization method, which presented the lowest failure probability was the LTSF (0.01), followed by ETO (0.21) and HPP (0.56). Automated cleansing obtained a better result than manual cleansing. This trial demonstrated that the probability of sterilization in reprocessed SUDP is highly dependent on both the type of cleansing and the sterilization method applied.

  20. Portable Chemical Sterilizer (PCS) for Surgical Instruments

    DTIC Science & Technology

    2004-12-01

    reactions, either individually or in combination, to effect sterilization of contaminated objects. The first system is a scaled up version of the...production by chemical reaction Ti quantities of heat, steam, and chlorine dioxide are produce that act in concert to effect the destruction of the...contaminating microorganisms. In fact, the conditions of heat and humidity created inside the PCS intensify the effectiveness of ClO2 as a lethal

  1. Mechanism for ordinary-sterile neutrino mixing

    SciTech Connect

    Langacker, P.

    1998-11-01

    Efficient oscillations between ordinary (active) and sterile neutrinos can occur only if Dirac and Majorana mass terms exist which are both small and comparable. It is shown that this can occur naturally in a class of string models, in which higher-dimensional operators in the superpotential lead to an intermediate scale expectation value for a scalar field and to suppressed Dirac and Majorana fermion masses. {copyright} {ital 1998} {ital The American Physical Society}

  2. Sterile neutrinos in the early universe

    SciTech Connect

    Malaney, R.A. ); Fuller, G.M. . Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  3. A Flash Sterilizer using Peracetic Acid

    DTIC Science & Technology

    1976-07-01

    REPORT 7606 / A FLASH STERILIZER USING PERACETIC ACID H. BRUCE CRANFORD, JR. C Reproduced From Best Available Copy US ARMY MEDICAL BIOENGINEERING...Operating Room area whereby an accidentally contaminated Instrument can be * rapidly resterilized using peracetic acid and returned to use was designedand...Pvoperties of Peracetic Acid 5 S..Proposed Design Approach 6 "Equipment 11 SUMM•ARY 17 BIBLIOGRAPHY 19 A*?ENDICES 23 A. Ltr, HQDA. (SGRD-SDM), WASH, DC, A-1

  4. Thermal In-Pouch Microwave Sterilization

    DTIC Science & Technology

    2012-01-09

    chicken piece placed at the cold spot in chicken- dumpling pouches at the end of complete thermal process. PA 3679 # 308 Clos- tridium sporogenes spore ...crop was used to calculate average D-values for the dif- ferent temperatures and determine the z-value of PA 3679 spores in chicken breast. Process...the developed MW sterilization processing delivered expected lethality to C. sporogenes PA 3679 spores . Forty chicken-dumpling pouches processed in

  5. International Agreement on Planetary Protection

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The maintenance of a NASA policy, is consistent with international agreements. The planetary protection policy management in OSS, with Field Center support. The advice from internal and external advisory groups (NRC, NAC/Planetary Protection Task Force). The technology research and standards development in bioload characterization. The technology research and development in bioload reduction/sterilization. This presentation focuses on: forward contamination - research on the potential for Earth life to exist on other bodies, improved strategies for planetary navigation and collision avoidance, and improved procedures for sterile spacecraft assembly, cleaning and/or sterilization; and backward contamination - development of sample transfer and container sealing technologies for Earth return, improvement in sample return landing target assessment and navigation strategy, planning for sample hazard determination requirements and procedures, safety certification, (liaison to NEO Program Office for compositional data on small bodies), facility planning for sample recovery system, quarantine, and long-term curation of 4 returned samples.

  6. International Agreement on Planetary Protection

    NASA Astrophysics Data System (ADS)

    2000-10-01

    The maintenance of a NASA policy, is consistent with international agreements. The planetary protection policy management in OSS, with Field Center support. The advice from internal and external advisory groups (NRC, NAC/Planetary Protection Task Force). The technology research and standards development in bioload characterization. The technology research and development in bioload reduction/sterilization. This presentation focuses on: forward contamination - research on the potential for Earth life to exist on other bodies, improved strategies for planetary navigation and collision avoidance, and improved procedures for sterile spacecraft assembly, cleaning and/or sterilization; and backward contamination - development of sample transfer and container sealing technologies for Earth return, improvement in sample return landing target assessment and navigation strategy, planning for sample hazard determination requirements and procedures, safety certification, (liaison to NEO Program Office for compositional data on small bodies), facility planning for sample recovery system, quarantine, and long-term curation of 4 returned samples.

  7. Sterilization of women: benefits vs risks.

    PubMed

    Rioux, J E

    Voluntary sterilization is the birth control method most widely practiced throughout the world. The last ten years have witnessed great improvements in techniques and perfection of innovations, explaining the important role that it now plays in the regulation of fertility. Different methods are examined and it is concluded that hysterectomy is the best, if medically indicated; conventional laparotomy is not justified unless required by concomitant intraabdominal pathology; minilaparotomy is mostly suitable postpartum; colpotomy is better left to specialists; laparoscopy is ideal for nonpregnant patients; culdoscopy is a relic of the past; and hysteroscopy, although still experimental, may be the way of the future. The advantages of voluntary sterilization lie in its remarkable and immediate efficiency, freedom from ongoing motivation, the convenience of a one-time operation, the absence of side effects and the reduction of total costs. Its disadvantages are the complexity of any surgical intervention for a woman, its indisputable finality, its uncertain legality and the risks inherent in any operation. Hysterectomy and tubal ligation are practically never fatal, so this argument does not influence the choice of either method. However, incidence of morbidity is higher following hysterectomies, which must therefore be justified. The balance is clearly in favor of voluntary sterilization for the woman who is convinced that the size of her family is complete.

  8. Sterilization of laparoscopes. Is soaking sufficient?

    PubMed

    Corson, S L; Block, S; Mintz, C; Dole, M; Wainwright, A

    1979-08-01

    Controversy exists over the proper methods of sterilizing laparoscopic telescopes. An edict requiring gas sterilization rather than solution soaking of these instruments is in force in all federal hospitals. This rule has necessitated capital investments for new instruments and has led to a severe reduction in the number of cases of laparoscopy that may be scheduled in one day. Fear of contamination is based on theoretical considerations and rusn counter to the actual, observed safety record seen with laparoscopes soaked in activated glutaraldehyde between cases. In an effort to dispassionately approach this problem, cultures of the umbilical area, the laparoscope and the pelvic serosal surfaces were taken to document the type of organisms commonly encountered under clinical conditions. Cultures for aerobic and anaerobic bacteria as well as for fungi were taken after soaking the telescope in activated glutaraldehyde. The results demonstrated growth of common skin organisms even after skin preparation with povidone-iodine and ethyl alcohol. Similar organisms were recovered in some cases from the laparoscope and the pelvic surfaces. The actual degree of contamination suggested by a colony count falls well within the range of the healthy peritoneum to cope with these organisms. Recommendations for laparoscopic sterilization or disinfection are based on the results obtained.

  9. Plasma sterilization using the RF glow discharge

    NASA Astrophysics Data System (ADS)

    Yang, Liqing; Chen, Jierong; Gao, Junling; Guo, Yafei

    2009-08-01

    In the present work, glow discharge oxygen plasma was used to sterilize the Pseudomonas aeruginosa on the polyethylene terephthalate (PET) sheets. In a self-designed plasma reaction equipment, active species (electron, ion, radical, UV light, etc.) were separated effectively, and the discharge area, afterglow area and remote area were plotted out in the plasma field. Before and after plasma treatment the cell morphology was studied by scanning electron microscopy (SEM). The results showed that after treatment of 30 s the germicidal effect is 4.26, 3. 84, 2.61, respectively in the three areas on the following conditions: discharge power was 40 W and gas flux was 20 cm 3/min. SEM results revealed the cell morphology before and after plasma treatment. The walls or cell membrane cracking was testified by determining the content of protein using coomassie light blue technique. The results from electron spin resonance spectroscopy (ESR) and double Langmuir electron probe showed that electron, ion and oxygen free radical played important roles in sterilization in the discharge area, but only oxygen radicals acted to sterilize the bacteria in the afterglow area and the remote area.

  10. Sterile Neutrino Search with the PROSPECT Experiment

    NASA Astrophysics Data System (ADS)

    Surukuchi Venkata, Pranava Teja

    2017-01-01

    PROSPECT is a multi-phased short-baseline reactor antineutrino experiment with primary goals of performing a search for sterile neutrinos and making a precise measurement of 235U reactor antineutrino spectrum from the High Flux Isotope Reactor at Oak Ridge National Laboratory. PROSPECT will provide a model independent oscillation measurement of electron antineutrinos by performing relative spectral comparison between a wide range of baselines. By covering the baselines of 7-12 m with Phase-I and extending the coverage to 19m with Phase-II, the PROSPECT experiment will be able to address the current eV-scale sterile neutrino oscillation best-fit region within a single year of data-taking and covers a major portion of suggested parameter space within 3 years of Phase-II data-taking. Additionally, with a Phase-II detector PROSPECT will be able to distinguish between 3+1 mixing, 3+N mixing and other non-standard oscillations. In this talk, we describe the PROSPECT oscillation fitting framework and expected detector sensitivity to the oscillations arising from eV-scale sterile neutrinos. DOE

  11. Post-ablation-tubal sterilization syndrome.

    PubMed

    Townsend, D E; McCausland, V; McCausland, A; Fields, G; Kauffman, K

    1993-09-01

    To determine the cause of unilateral or bilateral pelvic pain associated with vaginal spotting in women who had previously undergone tubal ligation followed by roller-ball endometrial ablation. Women who had undergone previous tubal sterilization followed by rollerball endometrial ablation were evaluated laparoscopically and hysteroscopically when they presented with a symptom complex of intermittent vaginal bleeding associated with severe cramping pain in the lower abdomen. During a 1.5-year observation period, six women with the symptom complex had laparoscopy and hysteroscopy. In all cases, marked endometrial scarring was noted. In every case, the proximal portions of either one or both fallopian tubes were swollen, and two cases had the appearance of an early ectopic pregnancy. In the remaining cases, the fallopian tubes were rubbery and swollen to as much as twice normal size. Symptoms in five of six patients subsided after laparoscopic removal of the oviduct. It appears that women who have had a tubal sterilization followed by endometrial ablation are at risk of developing an ectopic-like symptom complex. Salpingectomy appears to be effective in relieving symptoms. Whether this represents a new syndrome or just an unusual association between tubal sterilization and endometrial ablation remains to be seen.

  12. Radiation Sterilization of Prototype Military Foods

    PubMed Central

    Anellis, Abe; Berkowitz, D.; Jarboe, C.; El-Bisi, H. M.

    1967-01-01

    Ten lots of diced cured ham, packed in cans, were inoculated with approximately 106Clostridium botulinum spores per can. Each lot was seeded with a different strain (five type A and five type B strains). All cans were irradiated to various dose levels with Co60. Evidence provided by swelling, toxicity, and recoverable C. botulinum with 6,350 cans demonstrated that: (i) 4.5 Mrad was more than adequate as a sterilization dose; (ii) the minimal experimental sterilizing dose (ESD) based on nonswollen nontoxic endpoints was 2.0 < ESD ≤ 2.5 Mrad, and based on non-spoiled sterile cans was 3.0 < ESD ≤ 3.5 Mrad (the latter was supported by the computed theoretical 12D dose); (iii) D values calculated from botulinal survival data indicated that, as a group, the type A strains were more radioresistant than type B strains; strains 12885A and 41B, with respective D values of 0.242 and 0.175, represented the most resistant of each type; (iv) swollen cans did not always contain toxin, nor were toxic cans always swollen; (v) viable C. botulinum can exist for 6 months at 30 C without producing visible or toxic spoilage at doses of 3.0 Mrad and lower, including, in some instances, 0.0 Mrad; and (vi) a phenomenon similar to heat activation of spores occurred at sublethal radiation doses. Images Fig. 1 PMID:5340164

  13. [Principles of antisepsis, disinfection and sterilization].

    PubMed

    Hernández-Navarrete, María-Jesús; Celorrio-Pascual, José-Miguel; Lapresta Moros, Carlos; Solano Bernad, Victor-Manuel

    2014-12-01

    This article aims to provide a brief review of the main concepts on which the prevention and control of infection are based. Antisepsis comprises a set of techniques aimed at the total sterilization, or at most, disinfection, removing germs that contaminate an environment. Both procedures must be preceded by an environmental cleanup in the location in which they intend to be applied. The disinfection is carried out using biocides or germicides. Antimicrobial chemicals, that have mechanisms of action and resistances very similar to antibiotics, are generating concern due to the possibility of crossing genetic information that aggravates the problem of bacterial resistance. Most biocides can act as antiseptics, and applied to skin tissue, or disinfectants on inanimate materials. The spectrum of action of germicides depends on the product itself and external controllable factors: temperature, concentration, exposure time, etc. Sterilization techniques are primarily physical, by exposing the material to steam, or sterilizing gas, using autoclaves. Major advances are the use of low temperatures with shorter exposure times, in parallel with technological advances in instrumentation in order to avoid high temperatures and high use rotations due to workload. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  14. Sterile neutrinos as subdominant warm dark matter

    SciTech Connect

    Palazzo, A.; Cumberbatch, D.; Slosar, A.; Silk, J.

    2007-11-15

    In light of recent findings which seem to disfavor a scenario with (warm) dark matter entirely constituted of sterile neutrinos produced via the Dodelson-Widrow mechanism, we investigate the constraints attainable for this mechanism by relaxing the usual hypothesis that the relic neutrino abundance must necessarily account for all of the dark matter. We first study how to reinterpret the limits attainable from x-ray nondetection and Lyman-{alpha} forest measurements in the case that sterile neutrinos constitute only a fraction f{sub s} of the total amount of dark matter. Then, assuming that sterile neutrinos are generated in the early universe solely through the Dodelson-Widrow mechanism, we show how the x-ray and Lyman-{alpha} results jointly constrain the mass-mixing parameters governing their production. Furthermore, we show how the same data allow us to set a robust upper limit f{sub s} < or approx. 0.7 at the 2{sigma} level, rejecting the case of dominant dark matter (f{sub s}=1) at the {approx}3{sigma} level.

  15. Theory of oscillations and sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Palazzo, Antonio

    2014-11-01

    We present a concise review of the theoretical status of neutrino oscillations within the (standard) 3-flavor framework and the (non-standard) 4-flavor scheme endowed with one additional sterile species (the so-called 3+1 scheme). We emphasize the slight overall preference that recently emerged for CP-violation in the 3-flavor analysis and highlight the unique role of the global data combination in the near future. After a brief introduction of the motivations for light (eV) sterile neutrinos, we discuss the bounds on their mixing with the electron neutrinos, attainable from the solar sector. The upper limit so obtained is independent of the reactor neutrino fluxes, whose calculations are affected by systematic uncertainties not completely under control. Finally, we highlight the possibility to explore sub-eV "super-light" sterile neutrinos exploiting the θ13-dedicated reactor experiments also commenting on the robustness of the 3- flavor results within the enlarged 3+1 scheme.

  16. Dental burs and endodontic files: are routine sterilization procedures effective?

    PubMed

    Morrison, Archie; Conrod, Susan

    2009-02-01

    The complex miniature architecture of dental burs and endodontic files makes precleaning and sterilization difficult. Devising a sterilization protocol for endodontic files and dental burs requires care, and some have suggested that these instruments be considered single-use devices. One purpose of this study was to determine the effectiveness of various sterilization techniques currently used in dentistry for the resterilization of dental burs and endodontic files. The second aim was to determine whether new dental burs and endodontic files, as supplied in packages from the manufacturer, are sterile. The sterility of new (unused) and used dental burs and endodontic files before and after various sterilization procedures was analyzed. New burs and files were tested immediately after removal from manufacturers" packaging, with or without prior sterilization. Burs and files that had been used in various dental offices were precleaned, packaged, resterilized and then tested for various pathogens. Each item was individually removed from the sterilization packaging, transferred by sterile technique into Todd-Hewitt broth, incubated at 37 degrees C for 72 hours and observed for bacterial growth. Sterilization procedures were 100% effective for unused burs and unused files but were less than 100% effective for all other test groups. Contamination rates following sterilization ranged from 15% for one group of used burs (p = 0.01) to 58% for one group of used files (p < 0.001). Dental burs and endodontic files, as packaged by the manufacturer, are not sterile and should therefore be sterilized before first use. The resterilization procedures tested here were not adequate, and more rigorous sterilization procedures are needed. If such procedures cannot be devised, these instruments should perhaps be considered single-use devices.

  17. Surgical sterilization: an underutilized procedure for evaluating the merits of induced sterility

    USGS Publications Warehouse

    Kennelly, James J.; Converse, Kathryn A.

    1993-01-01

    Despite more than 4 decades of effort, development of effective wildlife damage control programs based on sterilization of target species has met with limited success. This is partly due to the fact that investigators have assumed, rather than empirically tested, whether the reproductive strategies of the target populations were vulnerable to the planned treatment. Equally important, methods selected to include sterility usually involve a chemical agent that can affect sociosexual behaviors of the nuisance population. In this report, we illustrate how surgically induced sterility circumvents both problems--how the concept without the potentially confounding secondary effects of a chemical. We assessed the merits of initiating research to develop a male chemosterilant for Norway rats, red-winged blackbirds, beaver, and Canada geese by inducing sterility surgically. The infidelity of many red-winged females to their polygynous territorial male was surprising and argued against searching for a male sterilant. On the other hand, beaver and Canada goose studies confirmed previous reports that both form par-bonds and are monogamous. Both should be vulnerable to a male chemosterilant approach, and research toward this goal is justified.

  18. [Calcium distribution in fertile and sterile anthers of a genic male sterile Chinese cabbage].

    PubMed

    Xie, Chao-Tian; Yang, Yan-Hong; Qiu, Yi-Lan; Ge, Li-Li; Tian, Hui-Qiao

    2005-12-01

    Potassium antimonite was used to locate calcium in the fertile and sterile anthers of a genic male sterile Chinese cabbage (Brassica campestris L. ssp. chinensis Makino) to probe the relation between Ca(2+) and fertility and sterility of anthers of the cabbage. During fertile anther development, calcium granules increase in number in anther wall cells after meiosis, and then appeared also in locule, suggesting a calcium influx into locule from anther wall cells (Plate I-4). Then the number of calcium granules in microspore cytoplasm also increased at early stage (Plate II-1), accumulated mainly on the membrane of small vacuoles which were fusing to form big ones to make a polarity in the cell and to prepare asymmetric division of microspore (Plate II-3,4). After microspore division and the big vacuole decomposition, many calcium granules accumulated again on the membrane of the vacuoles (Plate III-1,2), displaying calcium regulates vacuole formation and decomposition during pollen development. In sterile anthers, abnormal distribution of calcium granules first appeared in callus wall of microspore mother cell (Plate IV-1). However, only a few calcium granules appeared in early microspores, which then could not form small vacuoles and finally a big vacuole (Plate IV-2,3). The aborting microspores degenerate by cytoplasm shrinking (Plate IV-5,6). The difference pattern of distribution of calcium granules between the fertile and sterile anthers indicates that anomalies in the distribution of calcium accumulation are correlated with the failure of pollen development and pollen abortion.

  19. Sterile Insect Technique and F1 Sterility in the European Grapevine Moth, Lobesia botrana

    PubMed Central

    Saour, George

    2014-01-01

    Newly emerged adults of the European grapevine moth, Lobesia botrana (Denis and Schiffermuller) (Lepidoptera: Tortricidae), were irradiated with various doses of gamma radiation and crossed to unirradiated counterparts of the opposite sex. Fecundity was decreased when unirradiated females were mated with either 300- or 350-Gy-irradiated males. Adult males that were irradiated with 400 Gy and mated with unirradiated females retained a residual fertility of 2.7%. The radiation dose at which irradiated females were found to be 100% sterile when mated with unirradiated males was 150 Gy. The inherited effects in the F1 progeny of irradiated male parents were examined at 100, 150, and 200 Gy. Fecundity and fertility of the F1 progeny of males irradiated with 150 Gy and inbred or crossed with irradiated and unirradiated moths were also recorded. A significant reduction in fertility was observed when F1 males mated with either F1 or unirradiated females. According to sterility index, F1 females who mated with F1 males had greater sterility than when F1 females were crossed to 150-Gy-irradiated males. Based upon the results of this study, 150 Gy of gamma radiation would be the optimal dose to use in a sterile insect technique and F1 sterility program against L. botrana. PMID:25373155

  20. Sterile insect technique and F₁ sterility in the European grapevine moth, Lobesia botrana.

    PubMed

    Saour, George

    2014-01-23

    Newly emerged adults of the European grapevine moth, Lobesia botrana (Denis and Schiffermuller) (Lepidoptera: Tortricidae), were irradiated with various doses of gamma radiation and crossed to unirradiated counterparts of the opposite sex. Fecundity was decreased when unirradiated females were mated with either 300-or 350-Gy-irradiated males. Adult males that were irradiated with 400 Gy and mated with unirradiated females retained a residual fertility of 2.7%. The radiation dose at which irradiated females were found to be 100% sterile when mated with unirradiated males was 150 Gy. The inherited effects in the F1 progeny of irradiated male parents were examined at 100, 150, and 200 Gy. Fecundity and fertility of the F1 progeny of males irradiated with 150 Gy and inbred or crossed with irradiated and unirradiated moths were also recorded. A significant reduction in fertility was observed when F1 males mated with either F1 or unirradiated females. According to sterility index, F1 females who mated with F1 males had greater sterility than when F1 females were crossed to 150-Gy-irradiated males. Based upon the results of this study, 150 Gy of gamma radiation would be the optimal dose to use in a sterile insect technique and F1 sterility program against L. botrana.

  1. [Occupational health of endoscope sterilization workers in medical institutions in Osaka Prefecture].

    PubMed

    Miyajima, Keiko; Tabuchi, Takeo; Kumagai, Shinji

    2006-09-01

    To clarify the actual condition of endoscope sterilization work and the adverse health effects of disinfectants on personnel, a questionnaire was sent to 173 medical institutions in Osaka Prefecture. Glutaraldehyde (GA), ortho-phtalaldehyde (OPA), and hyperacetic acid were used as disinfectants of endoscopes by 55.5%, 32.4%, and 8.7% of the medical institutions respectively. The kind of disinfectant used had been changed in 57.8% of these institutions during the past five years, and it was confirmed that the use of substitutes for GA, such as OPA and hyperacetic acid, has increased. Personnel in 35.8% of the institutions complained about symptoms during sterilization work. The kind of disinfectant being used when they complained was GA in many cases and OPA in others. A general ventilation system has now been installed in 72.3% of the institutions; local exhaust systems have been installed in fewer, only 23.4%. Protective gloves were used at about half of the institutions, but protective masks and glasses were seldom used. This study shows that the occupational health problems of endoscope sterilization work have not been resolved. Consequently, it is necessary to promote the installation of ventilation systems and the use of protective devices in all institutions. Health education in regard to the handling of disinfectants is also necessary. Because little information is available about the toxic effects of OPA and hyperacetic acid, epidemiological studies must be conducted to clarify the human health effect of these disinfectants.

  2. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study.

    PubMed

    Raju, T B V G; Garapati, Satish; Agrawal, Rupika; Reddy, Sridhara; Razdan, Ankur; Kumar, S Kishore

    2013-12-01

    Aim of the study was to compare 4 different methods of sterilizing endodontic files in dental practice. The present study was performed on 100 K-files, 21 mm long and of size 25. Of these, 20 files were taken as control group, and the remaining 80 files were divided into 4 groups of 20 files each and they were tested for the efficacy of sterilization with different methods: Autoclave, glass bead, glutaraldehyde and CO2 laser. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization. How to cite this article: Raju TB, Garapati S, Agrawal R, Reddy S, Razdan A, Kumar SK. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study. J Int Oral Health 2013; 5(6):108-12 .

  3. Electron sterilization validation techniques using the controlled depth of sterilization process

    NASA Astrophysics Data System (ADS)

    Cleghorn, Denise A.; Nablo, Sam V.

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. most of these products are filled under aseptic conditions so that for qualification as a sterile product, techniques are often required only for treatment of the container surfaces and package interior. Gas sterilization (ETO) is often used for this purpose but is beset with difficulties known to the reader, especially for critical "contact" products such as in the ophthalmic field. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and x-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating x-ray dose ratios are possible for the application of the technique. Some of these data illustrating package: parenteral ratios of 10 5:1 have been reported (Rangwalla et al, 1985; Aaronson and Nablo, 1988). Standard techniques have been developed for the validation of the process and are reported here. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed.

  4. Some aspects of the sterilization program in Malaysia.

    PubMed

    Arshat, H; Ali, J; Noor Laily Abu Bakar

    1984-06-01

    Sterilization is most often indicated when the desired family size is reached and no more children are desired. Because of technical advances and societal changes surgical sterilization is increasingly becoming the most utilized method of contraception. Since female sterilization is more common, several methods have been devised to make it safe and reliable. The traditional large abdominal incision (laparotomy) is now replaced by minilaparotomy, which is a small abdominal incision. Other techniques, such as transvaginal and trancervical approaches require no incision at all. These method permit occlusion of any part of the fallopian tube. Minilapatomy is the recommended method of female sterilization for 3rd world countries. Laparoscopic sterilization appears to be more psychologically acceptable to 3rd world women who have an inherent dread of surgery. A higher incidence of hematoma formation has been reported in puerperal laparoscopic sterilizations and the failure rate is also higher than in other methods. Other complications associated with laparoscopic sterilization include wound sepsis, surgical emphysema of the parieties and uterine perforation. Laparoscopic sterilizations can be performed under local, general, spinal or epidural anesthesia. Local and general anesthesia is the commonest. Both tubal ligations and vasectomies have been available in Malaysia since the 1960s. Laparoscopy was 1st introduced in Malaysia in the early 1970s. Several laparoscopy centers have been established in Malaysia to provide specialized family planning services. Outpatient laparoscopic sterilization is a feature of the Kuala Lumpur Specialist Center. Traditonally doctors and specialists in Malaysia received their practical training in sterilization techniques during their internship or residency. Since 1980, however, a formal training program was initiated. Because laparoscopy provides interval sterilization without major abdominal surgery, this procedure has played a major

  5. Sterilization Resistance of Bacterial Spores Explained with Water Chemistry.

    PubMed

    Friedline, Anthony W; Zachariah, Malcolm M; Middaugh, Amy N; Garimella, Ravindranath; Vaishampayan, Parag A; Rice, Charles V

    2015-11-05

    Bacterial spores can survive for long periods without nutrients and in harsh environmental conditions. This survival is influenced by the structure of the spore, the presence of protective compounds, and water retention. These compounds, and the physical state of water in particular, allow some species of bacterial spores to survive sterilization schemes with hydrogen peroxide and UV light. The chemical nature of the spore core and its water has been a subject of some contention and the chemical environment of the water impacts resistance paradigms. Either the spore has a glassy core, where water is immobilized along with other core components, or the core is gel-like with mobile water diffusion. These properties affect the movement of peroxide and radical species, and hence resistance. Deuterium solid-state NMR experiments are useful for examining the nature of the water inside the spore. Previous work in our lab with spores of Bacillus subtilis indicate that, for spores, the core water is in a more immobilized state than expected for the gel-like core theory, suggesting a glassy core environment. Here, we report deuterium solid-state NMR observations of the water within UV- and peroxide-resistant spores from Bacillus pumilus SAFR-032. Variable-temperature NMR experiments indicate no change in the line shape after heating to 50 °C, but an overall decrease in signal after heating to 100 °C. These results show glass-like core dynamics within B. pumilus SAFR-032 that may be the potential source of its known UV-resistance properties. The observed NMR traits can be attributed to the presence of an exosporium containing additional labile deuterons that can aid in the deactivation of sterilizing agents.

  6. Single- and multiple-clade influenza A H5N1 vaccines induce cross protection in ferrets

    PubMed Central

    Forrest, Heather L.; Khalenkov, Alexey M.; Govorkova, Elena A.; Kim, Jeong-Ki; Giudice, Giuseppe Del; Webster, Robert G.

    2009-01-01

    The rapid evolution, genetic diversity, broad host range, and increasing human infection with avian influenza A (H5N1) viruses highlight the need for an efficacious cross-clade vaccine. Using the ferret model, we compared induction of cross-reactive immunity and protective efficacy of three single-clade H5N1 vaccines and a novel multiple-clade H5N1 vaccine, with and without MF59 adjuvant. Reverse genetics (rg) was used to generate vaccine viruses containing the hemagglutinin (HA) and neuraminidase genes of wild-type H5N1 viruses. Ferrets received 2 doses of inactivated whole-virus vaccine separated by 3 weeks. Single-clade vaccines (7.5 μg HA per dose) included rg-A/Vietnam/1203/04 (clade 1), rg-A/Hong Kong/213/03 (clade 1), and rg-A/Japanese white eye/Hong Kong/1038/06 (clade 2.3). The multiple-clade vaccine contained 3.75 μg HA per dose of each single-clade vaccine and of rg-A/Whooper Swan/Mongolia/244/05 (clade 2.2). Two doses of vaccine were required to substantially increase anti-HA and virus neutralizing antibody titers to H5N1 viruses. MF59 adjuvant enhanced induction of clade-specific and cross-clade serum antibody responses, reduced frequency of infection (as determined by upper respiratory tract virus shedding and seroconversion data), and eliminated disease signs. The rg-A/Hong Kong/213/03 vaccine induced the highest antibody titers to homologous and heterologous H5N1 viruses, while rg-A/Japanese white eye/Hong Kong/1038/06 vaccine induced the lowest. The multiple-clade vaccine was broadly immunogenic against clade 1 and 2 viruses. The rg-A/Vietnam/1203/04 vaccine (the currently stockpiled H5N1 vaccine) most effectively reduced upper respiratory tract virus shedding after challenge with clade 1 and 2 viruses. Importantly, all vaccines protected against lethal challenge with A/Vietnam/1203/04 virus and provided cross-clade protection. PMID:19406182

  7. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    PubMed

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe

  8. Mars Technology Program: Planetary Protection Technology Development

    NASA Technical Reports Server (NTRS)

    Lin, Ying

    2006-01-01

    This slide presentation reviews the development of Planetary Protection Technology in the Mars Technology Program. The goal of the program is to develop technologies that will enable NASA to build, launch, and operate a mission that has subsystems with different Planetary Protection (PP) classifications, specifically for operating a Category IVb-equivalent subsystem from a Category IVa platform. The IVa category of planetary protection requires bioburden reduction (i.e., no sterilization is required) The IVb category in addition to IVa requirements: (i.e., terminal sterilization of spacecraft is required). The differences between the categories are further reviewed.

  9. BEST sensitivity to O(1) eV sterile neutrino

    NASA Astrophysics Data System (ADS)

    Barinov, Vladislav; Gavrin, Vladimir; Gorbunov, Dmitry; Ibragimova, Tatiana

    2016-04-01

    Numerous anomalous results in neutrino oscillation experiments can be attributed to the interference of an ˜1 eV sterile neutrino. The Baksan Experiment on Sterile Transitions (BEST), specially designed to fully explore the Gallium anomaly, starts next year. We investigate the sensitivity of BEST in search of a sterile neutrino mixed with an electron neutrino. Then, performing the combined analysis of all the Gallium experiments (SAGE, GALLEX, BEST), we find the region in the model parameter space (sterile neutrino mass and mixing angle) which will be excluded if BEST agrees with no sterile neutrino hypothesis. For the opposite case, if BEST observes the signal as it follows from the sterile neutrino explanation of the Gallium (SAGE and GALLEX) anomaly, we show how BEST will improve upon the present estimates of the model parameters.

  10. Social and psychological perspectives on voluntary sterilization: a review.

    PubMed

    Philliber, S G; Philliber, W W

    1985-01-01

    This paper reviews social science research on the antecedents and consequences of voluntary sterilization. The major conclusions are that socioeconomic status has little impact on the decision to be sterilized and that sterilizations are rare among those without sons and among male non-whites. Significant others are important sources of encouragement and information, and good marital relations increase the likelihood of having the procedure performed. Most acceptors experience no change in sexual activity, quality of marital relationships, or work-related behavior, and few regret their choice. Negative consequences are more likely among those in India, those coerced into having a sterilization, those who did not understand the consequences of the procedure, those with health complications after sterilization, and those couples who have unstable marriages or who disagree about sterilization.

  11. Continuous-sterilization system that uses photosemiconductor powders.

    PubMed

    Matsunaga, T; Tomoda, R; Nakajima, T; Nakamura, N; Komine, T

    1988-06-01

    We report a novel photochemical sterilization system in which Escherichia coli cells were sterilized with photosemiconductor powders (titanium oxide). For sterilization that could be used in practice, it was necessary to separate the TiO2 powders from the cell suspension. Therefore, semiconductor powders were immobilized on acetylcellulose membranes. We constructed a continuous-sterilization system consisting of a TiO2-immobilized acetylcellulose membrane reactor, a mercury lamp, and a masterflex pump. As a result, under the various sterilization conditions examined, E. coli (10(2) cells per ml) was sterilized to less than 1% survival when the cell suspension flowed in this system at a mean residence time of 16.0 min under irradiation (1,800 microeinsteins/m2 per s). We found that this system was reusable.

  12. Characterization of a new VHF-CCP for Sterilization

    NASA Astrophysics Data System (ADS)

    Stapelmann, Katharina; Bibinov, Nikita; Wunderlich, Joachim; Awakowicz, Peter

    2009-10-01

    Plasma sterilization is an upcoming alternative to common sterilization methods. Reduced process times combined with a low treatment temperature lead to proper sterilization and decontamination results even for heat-sensitive materials. The capabilities of plasma sterilization were demonstrated in several laboratory setups. Based on these experiences, a new plasma reactor was developed and realized as capacitive coupled plasma discharge with a variable frequency range between 76 and 80 MHz. The reactor concept is designed to meet industrial needs. Therefore, a specialized chamber design was developed: it is composed of PEEK, a high-performance plastic, and it is shaped like a drawer to make the sterilization process easy and uncomplicated for application. Optical Emission Spectroscopy was performed to obtain detailed information about the plasma parameters. According spectra, intensities and plasma parameters will be presented in comparison to a well established ICP laboratory setup. These data are used for optimization of sterilization efficiency. Furthermore, first microbiological tests were carried out at optimized conditions.

  13. Assessment of performance of UV sterilizer for room air bacteria.

    PubMed

    Joshi, P V

    2002-02-01

    Paper presents a technique for performance of UV sterilizer for room air bacteria. Patterns of decay of room air bacteria concentration during sterilization and build-up there after as a function of time is studied. Decay process seems to follow exponential pattern. Half-lives during decay are estimated. For single sterilizer unit with a dose of 16 W the decay half-life is around 8.6 min. For the dose of 32 W (2 sterilizers), half-life is estimated to be 6.18 min. The removal rates of room air bacteria due to sterilizer are compared with the natural decay of aerosols at steady state. The importance of decay half-life in the assessment has been stated. The bacteria concentration buildup process after putting off the sterilizers seems to be sigmoidal in nature. The buildup half-life is estimated to be around 53 min for present experimental conditions.

  14. Continuous-sterilization system that uses photosemiconductor powders. [Escherichia coli

    SciTech Connect

    Matsunaga, T.; Tomoda, R.; Nakajima, T.; Nakamura, N.; Komine, T.

    1988-06-01

    We report a novel photochemical sterilization system in which Escherichia coli cells were sterilized with photosemiconductor powders (titanium oxide). For sterilization that could be used in practice, it was necessary to separate the TiO/sub 2/ powders from the cell suspension. Therefore, semiconductor powders were immobilized on acetylcellulose membranes. We constructed a continuous-sterilization system consisting of TiO/sub 2/-immobilized acetylcellulose membrane reactor, a mercury lamp, and a masterflex pump. As a result, under the various sterilization conditions examined, E.coli (10/sup 2/ cells per ml) was sterilized to < 1% survival when the cell suspension flowed in this system at a mean residence time of 16.0 min under irradiation (1800 microeinsteins/m/sup 2/ per s). We found that this system was reusable.

  15. Sterilization of the biological safety cabinet

    PubMed Central

    Newsom, S. W. B.; Walsingham, B. M.

    1974-01-01

    Test strips comprising B subtilis spores or M phlei cells dried on aluminium foil (some serum-coated) were used to test sterilizing processes currently advised for safety cabinets. Exposure to formalin from a bowl, boiling excess formalin with the fan running, and ultraviolet radiation were all found to be unreliable, as was glutaraldehyde. Vaporization of 2 ml of formalin per 0·028 m3 followed by exposure for 18 hours at ambient temperatures was 100% successful, and the depolymerization of paraformaldehyde tablets with a hair drier was a simple, very effective alternative method. PMID:4216601

  16. Investigating CPT Conservation in Sterile Neutrino Fits

    NASA Astrophysics Data System (ADS)

    Ignarra, Christina

    2010-02-01

    We investigate compatibility between neutrino and antineutrino short-baseline oscillation experiments under a two-neutrino oscillation hypothesis due to a sterile neutrino at δm^2˜1 eV^2. We explore the preliminary MINOS antineutrino disappearance results as well as antineutrino oscillation results from LSND, MiniBooNE, KARMEN, Bugey, and Chooz, and neutrino oscillation results from NOMAD, MiniBooNE, CCFR84, and CDHS. We find that a combined fit of the antineutrino data yields a high chi-squared probability, while the global fit including neutrino and antineutrino data yields high incompatibility. CPT-violating fits within this scenario are also explored. )

  17. Search for sterile neutrinos at reactors

    NASA Astrophysics Data System (ADS)

    Yasuda, Osamu

    2011-09-01

    The sensitivity to the sterile neutrino mixing at very short baseline reactor neutrino experiments is investigated. In the case of conventional (thermal neutron) reactors it is found that the sensitivity is lost for ∆ m 2 ≳ 1 eV2 due to smearing of the reactor core size. On the other hand, in the case of an experimental fast neutron reactor Joyo, because of its small size, sensitivity to sin2 2 θ 14 can be as good as 0.03 for ∆ m 2 ˜ several eV2 with the Bugey-like detector setup.

  18. Urinary mycobacterium avium presenting as sterile pyuria

    PubMed Central

    Yang, Kai; Samplaski, Mary; Mazzulli, Tony; Lo, Kirk; Grober, Ethan; Jarvi, Keith Allen

    2016-01-01

    A 65-year-old healthy woman presented with persistent, asymptomatic sterile pyuria detected by her family physician. While she did not have symptoms, the patient recounts that she has had cloudy urine for years. Cultures of the urine for bacteria showed no growth and no fungi were identified. First-morning urine samples were sent for both tuberculosis and nontuberculosis mycobacterium species testing. The culture grew genotypically identified Mycobaterium avium complex (MAC). Mantoux skin testing was positive. No urological abnormalities were detected by ultrasound and computed tomography (CT) imaging of the urinary tract. PMID:27790302

  19. Cross-cultural attitudes toward voluntary sterilization.

    PubMed

    Hong, S

    1985-06-01

    The degree to which voluntary sterilization (VS) is accepted as a form of fertility control throughout the world was assessed by examining the prevalence and legal status of VS in all countries for which information was available and by examining current religious and traditional attitudes toward VS. Information on VS prevalence for 73 countries indicates that in 28 countries, 10% of all eligible couples rely on VS. In a number of countries, including Korea, New Zealand, Panama, US, and Puerto Rico, 25% or more of all currently married women of reproductive age rely on VS. VS prevalence rates tend to be higher in Asian countries than in African, Latin American, and Middle Eastern countries. In a number of countries, the average age and family size of VS acceptors is declining. Information on the legal status of VS for 124 countries indicates that 22 countries have laws which permit or encourage VS. These countries contain 13.4% of the world's population. In 54 countries, representing 60% of the world's population, there are no laws restricting VS, and VS is generally assumed to be legal. In 29 countries, representing 14% of world's population, the legal status of VS is unclear. In the remaining 29 countries, sterilization is forbidden except for medical or eugenic reasons. The degree to which these laws actually restrict VS varies from country to country. For example in Indonesia VS is illegal but widely practiced. Although some religious teachings discourage sterilization, the impact of religion on VS varies considerably from country to country. In the Catholic countries of Panama, Dominican Republic, and Philippines the prevalence of VS is high, and in the Catholic countries of Argentina, Bolivia, and Uruguay the prevalence of VS is low. VS prevalence is generally low in Muslim countries, but high in the Muslim countries of Tunisia, Indonesia, and Bangladesh. VS prevalence is high in the Buddhist country of Thailand but low in the Buddhist country of Burma

  20. Mitochondria and cytoplasmic male sterility in plants.

    PubMed

    Hu, Jun; Huang, Wenchao; Huang, Qi; Qin, Xiaojian; Yu, Changchun; Wang, Lili; Li, Shaoqing; Zhu, Renshan; Zhu, Yingguo

    2014-11-01

    Mitochondria are essential organelles in cells not only because they supply over 90% of the cell's energy but also because their dysfunction is associated with disease. Owing to the importance of mitochondria, there are many questions about mitochondria that must be answered. Cytoplasmic male sterility (CMS) is a mysterious natural phenomenon, and the mechanism of the origin of CMS is unknown. Despite successful utilization of CMS and restoration of fertility (Rf) in practice, the underlying mechanisms of these processes remain elusive. This review summarizes the genes involved in CMS and Rf, with a special focus on recent studies reporting the mechanisms of the CMS and Rf pathways, and concludes with potential working models.

  1. [Laparoscopic abdominal drainage by sterile destructive pancreatitis].

    PubMed

    Kuznetsov, N A; Rodoman, G V; Shalaeva, T I; Trefilova, O I; Sosikova, N L

    2009-01-01

    90 patients with acute pancreatitis were observed, in 60 of them laparoscopic drainage was performed. The procedure by sterile pancreatonecrosis is indicated only in presence of extent amount of exudate in abdominal cavity. Duration of draining the abdominal cavity should be strictly limited because of the high risk of septic complications. Contraindications for the abdominal drainage by acute necrotic pancreatitis are not only adhesions in the abdomen and shock state of the patient at the moment of procedure necessity, but also unstable hemodynamics in anamnesis and even by the arterial pressure downtrend.

  2. The incubation period in sterility testing.

    PubMed

    Bathgate, H; Lazzari, D; Cameron, H; McKay, D

    1993-01-01

    Sterility test results gathered over a ten year period have been analysed to determine the effects of the incubation period. Overall there was no difference between the membrane filtration test and direct inoculation in the time required for visible growth of contaminants. Growth occurred earlier if products had no preservative or antimicrobial substances. However use of the membrane filtration method did not significantly enhance the efficiency of detection at seven days incubation. Regardless of the nature of the product or the method of test an unacceptable proportion of contaminants would be missed by limiting incubation to seven days.

  3. Search for sterile neutrinos at RENO

    NASA Astrophysics Data System (ADS)

    Yeo, In Sung; RENO Collaboration

    2017-09-01

    The RENO experiment was designed to measure a neutrino mixing angle, θ13, by detecting electron antineutrinos emitted from the Hanbit nuclear reactors in Korea, and succeeded to measure θ13 from the disappearance mode in three neutrino frame. We investigate the possibility of sterile neutrinos existence at RENO experiment and compare data with Monte Carlo generated in four neutrino frame. In this talk, we present some recent results using chi-square analysis method. The probability deficit curve as a function of an effective baseline and the excluded contour plot in sin2(2 θ14) – Δ(m41)2 space will be shown.

  4. Light sterile neutrinos from large extra dimensions

    NASA Astrophysics Data System (ADS)

    Ma, E.; Rajasekaran, G.; Sarkar, U.

    2000-12-01

    An experimentally verifiable Higgs-triplet model of neutrino masses from large extra dimensions was recently proposed. We extend it to accommodate a light sterile neutrino which also mixes with the three active neutrinos. Another extension without the Higgs triplet allows the specific realization of a previously proposed phenomenological model of neutrino oscillations with decay to account for the LSND data, which is now the only viable such model now left, in view of the latest atmospheric and solar neutrino-oscillation data from the Super-Kamiokande collaboration.

  5. Possibilities of sterilization by track membranes

    NASA Astrophysics Data System (ADS)

    Kudoyarov, M. F.; Vishnevskii, B. I.; Manicheva, O. A.; Myakotina, E. N.; Mukhin, S. A.; Patrova, M. Ya.; Vedmetskii, Yu. V.

    2011-09-01

    The possibility of using track membranes for the dimensional separation of Mycobacterium tuberculosis (MBT) species from liquid media has been studied. A set of track membranes with various pore diameters was prepared at the accelerator complex of the Ioffe Physical Technical Institute (St. Petersburg) and all samples were tested for their ability to separate MBT species of 13 strains from solutions. The results showed high ability of the track membranes with pore diameters from 180 to 300 nm to sterilize liquid media and confirmed the hypothesis concerning relatively high rigidity of these bacteria.

  6. A standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy

    PubMed Central

    2010-01-01

    Background Intra-operative fluoroscopy for orthopaedic procedures frequently involves imaging in the horizontal plane, which requires the lower portion of the C-arm (x-ray tube) to be rotated from an unsterile zone (beneath the table) into the sterile field. To protect the integrity of the sterile field the C-arm must be draped repeatedly throughout the surgical case. The current, un-standardized, practice employs draping procedures which violate the Association of peri-Operative Registered Nurses (AORN) Standards and Recommended Practices, waste time and material, and pose an increased risk for surgical site infection. Presentation of the hypothesis Use of a novel sterile C-arm drape (C-armor) that maintains the integrity of the sterile field, will improve operating room efficiency and reduce surgical site infection risk factors. This reduction in risk factors may potentially reduce surgical site infections in orthopaedic surgical cases requiring repeated horizontal x-ray imaging. Testing the Hypothesis Savings in time and material and the reduction in surgical site infection risk factors afforded by using C-armor are intuitive to those skilled in the practice of orthopaedic surgery. Testing for a reduction in the number of microorganisms introduced to the surgical site by improved C-arm draping would be challenging due to the multiple confounding factors during a surgical operation. Determination of an absolute reduction in surgical site infections may be possible, but will require accounting for many confounding variables and a large study sample in order to achieve statistical significance. Implications of the Hypothesis Improved intraoperative workflow, healthcare savings and a reduction in surgical site infection risk factors will be achieved by utilizing a standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy. PMID:21144027

  7. Microwave sterilization of Candida on underwear fabric. A preliminary report

    SciTech Connect

    Friedrich, E.G. Jr.; Phillips, L.E.

    1988-05-01

    Candida-contaminated underwear might not be sterilized by ordinary laundering. The effectiveness of microwaving against Candida albicans on fabric was therefore determined. Swatches of Candida-impregnated cotton underpants fabric were subjected to domestic microwaving at the high setting for up to 30 minutes. If the fabric was microwaved dry, the Candida organisms survived. If the fabric was moistened, sterilization occurred within five minutes. Microwaving wet, freshly laundered cotton underpants should sterilize residual Candida and reduce the risk of reinfection.

  8. On the intrinsic sterility of 3D printing

    PubMed Central

    Flynn, Kaitlin J.; Zaman, Luis; Tung, Emily; Pudlo, Nicholas

    2016-01-01

    3D printers that build objects using extruded thermoplastic are quickly becoming commonplace tools in laboratories. We demonstrate that with appropriate handling, these devices are capable of producing sterile components from a non-sterile feedstock of thermoplastic without any treatment after fabrication. The fabrication process itself results in sterilization of the material. The resulting 3D printed components are suitable for a wide variety of applications, including experiments with bacteria and cell culture. PMID:27920950

  9. Sterilization analysis of contaminated healing abutments and impression copings.

    PubMed

    Browne, Vanessa; Flewelling, Michael; Wierenga, Mark; Wilson, Alisa; Aprecio, Ray; Richardson, Paul; Angelov, Nikola; Johnson, Neal

    2012-05-01

    This study investigated sterilization of used implant impression copings and healing abutments. Components were analyzed after contamination with Enterococcus foecalis, followed by multiple rounds of sterilization by both steam autoclave and Chemiclave protocols. The authors' results demonstrated that used components showed sterility equal to new components without any visible distortion. These data suggest that component resterilization and reuse may be justified or at least considered in clinical practice. Also, implications for cost savings in the placement of implants are advanced.

  10. Defective pollen wall contributes to male sterility in the male sterile line 1355A of cotton

    PubMed Central

    Wu, Yuanlong; Min, Ling; Wu, Zancheng; Yang, Li; Zhu, Longfu; Yang, Xiyan; Yuan, Daojun; Guo, Xiaoping; Zhang, Xianlong

    2015-01-01

    To understand the mechanisms of male sterility in cotton (Gossypium spp.), combined histological, biochemical and transcription analysis using RNA-Seq was carried out in the anther of the single-gene recessive genic male sterility system of male sterile line 1355A and male fertile line 1355B, which are near-isogenic lines (NILs) differing only in the fertility trait. A total of 2,446 differentially expressed genes were identified between the anthers of 1355AB lines, at three different stages of development. Cluster analysis and functional assignment of differentially expressed genes revealed differences in transcription associated with pollen wall and anther development, including the metabolism of fatty acids, glucose, pectin and cellulose. Histological and biochemical analysis revealed that a major cellular defect in the 1355A was a thicker nexine, consistent with the RNA-seq data, and further gene expression studies implicated differences in fatty acids synthesis and metabolism. This study provides insight into the phenotypic characteristics and gene regulatory network of the genic male sterile line 1355A in upland cotton. PMID:26043720

  11. Bactrocera dorsalis male sterilization by targeted RNA interference of spermatogenesis: empowering sterile insect technique programs

    PubMed Central

    Dong, Yong-Cheng; Wang, Zhi-Jian; Chen, Zhen-Zhong; Clarke, Anthony R.; Niu, Chang-Ying

    2016-01-01

    RNA interference (RNAi) is a genetic technique which has novel application for sustainable pest control. The Sterile Insect Technique (SIT) uses releases of mass-produced, sterile male insects to out-compete wild males for mates to reduce pest populations. RNAi sterilization of SIT males would have several advantages over radiation sterilization, but to achieve this appropriate target genes must first be identified and then targeted with interference technology. With this goal, eight spermatogenesis related candidate genes were cloned and tested for potential activity in Bactrocera dorsalis. The knockdown of candidate genes by oral delivery of dsRNAs did not influence the mating of male flies, but significantly affected the daily average number of eggs laid by females, and reduced egg hatching rate by 16–60%. RNAi negatively affected spermatozoa quantitatively and qualitatively. Following the mating of lola-/topi-/rac-/rho-/upd-/magu-silenced males, we recorded a significant decrease in number and length of spermatozoa in female spermatheca compared to gfp-silenced control group. In a greenhouse trial, the number of damaged oranges and B. dorsalis larvae were significantly reduced in a dsrho-treated group compared with the dsgfp group. This study provides strong evidence for the use RNAi in pest management, especially for the improvement of SIT against B. dorsalis and other species. PMID:27767174

  12. Evaluation of sterility and fertility of male sterile lines in the USPB farm

    USDA-ARS?s Scientific Manuscript database

    Hybrid rice has proven to have a yield advantage of 15–20% over the best inbred cultivars at the commercial scale worldwide. At present, two methods have been successfully commercialized; the three-line and two-line systems. The three-line system consists of the male sterile (MS), maintainer and res...

  13. Bactrocera dorsalis male sterilization by targeted RNA interference of spermatogenesis: empowering sterile insect technique programs.

    PubMed

    Dong, Yong-Cheng; Wang, Zhi-Jian; Chen, Zhen-Zhong; Clarke, Anthony R; Niu, Chang-Ying

    2016-10-21

    RNA interference (RNAi) is a genetic technique which has novel application for sustainable pest control. The Sterile Insect Technique (SIT) uses releases of mass-produced, sterile male insects to out-compete wild males for mates to reduce pest populations. RNAi sterilization of SIT males would have several advantages over radiation sterilization, but to achieve this appropriate target genes must first be identified and then targeted with interference technology. With this goal, eight spermatogenesis related candidate genes were cloned and tested for potential activity in Bactrocera dorsalis. The knockdown of candidate genes by oral delivery of dsRNAs did not influence the mating of male flies, but significantly affected the daily average number of eggs laid by females, and reduced egg hatching rate by 16-60%. RNAi negatively affected spermatozoa quantitatively and qualitatively. Following the mating of lola-/topi-/rac-/rho-/upd-/magu-silenced males, we recorded a significant decrease in number and length of spermatozoa in female spermatheca compared to gfp-silenced control group. In a greenhouse trial, the number of damaged oranges and B. dorsalis larvae were significantly reduced in a dsrho-treated group compared with the dsgfp group. This study provides strong evidence for the use RNAi in pest management, especially for the improvement of SIT against B. dorsalis and other species.

  14. Differences in the Access to Sterilization between Women Living and Not Living with HIV: Results from the GENIH Study, Brazil

    PubMed Central

    Cabral, Cristiane da Silva; do Lago, Tania di Giacomo; Pinho, Adriana de Araujo

    2016-01-01

    differences regarding the impact of HIV infection at sterilization are observed depending on the timing and the type of sterilization procedure. The probability of obtaining an interval sterilization is significantly lower for WLHIV compared to those not living with HIV. The reverse occurs regarding postpartum sterilization. Although sterilization is mainly performed in conjunction with caesarean section in Brazil, it is evident that caesarean sections are not the sole factor increasing the risk of sterilization among WLHIV. Conclusion The results indicate barriers in the access to services offering interval sterilization for WLHIV and certain facilitation in obtaining the procedure in conjunction with caesarean section. Health policy makers at local and national levels should promote institutional changes in order to facilitate access to interval sterilization and to confront the sensitive discussion of WLHIV’s eligibility for postpartum sterilization. It is also urgent to increase access to a wider range of contraceptive methods for WLHIV and promote dual method protection strategies. Moreover, since condom use may decrease in the future in the context of the preventive effect of antiretroviral therapy, promoting dual methods will expand the choices regarding the reproductive rights of women living with HIV. PMID:27812146

  15. [A survey of ethylene oxide sterilization in a hospital].

    PubMed

    Fujishiro, K; Mori, K; Inoue, N

    1991-09-01

    The health and environmental problems of ethylene oxide gas sterilization in a hospital are reported. Eight nurses who had been engaged in the gas sterilization, sometimes operated the auto-sterilizer in an inadequate manner; they exposed more than several hundred ppm of ethylene oxide once or twice a week. The main acute effects on these nurses after massive exposure were headaches, general fatigue and irritation of the eyes and throat. But no signs of polyneuropathy were seen. This survey suggests that there is a great risk of ethylene oxide poisoning while sterilizing instruments in a hospital.

  16. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    PubMed

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  17. Dark matter relic abundance and light sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Tang, Yi-Lei; Zhu, Shou-hua

    2017-01-01

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲ 100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y N between the Higgs and the sterile neutrino is small, this process gives rise to a larger ΩDM h 2 so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  18. Application of vapor phase hydrogen peroxide sterilization to endoscope.

    PubMed

    Shintani, Hideharu

    2009-03-01

    An advantage of vapor phase hydrogen peroxide (VPHP) is that it can readily react to form reactive free radicals, which perform the sterilization and form water and hydrogen by catalyst. Absorptive hydrophilic materials such as cellulosics hinder penetration due to hydrogen bonding and necessitate the use of hydrophobic materials, i.e., polyethylene or polypropylene, as packaging materials. The 8h TWA (time-weight-average) is 1 ppm. Hydrogen peroxide sterilization is now being used for the sterilization of gloveboxes, freeze dryers, isolators and endoscopes and so on. This paper focuses on the application of VPHP to the sterilization of the endoscopes.

  19. System and method of applying energetic ions for sterilization

    DOEpatents

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and across the cold plasma, is provided.

  20. Sterility Test Method for Petrolatum-Based Ophthalmic Ointments

    PubMed Central

    Tsuji, Kiyoshi; Stapert, E. M.; Robertson, John H.; Waiyaki, Peter M.

    1970-01-01

    A sensitive sterility testing procedure for the detection of microbial contamination in petrolatum-based ointments is described. The method involves dissolving the ointment in filter-sterilized isopropyl myristate and filtering through a membrane filter. Improved sensitivity is obtained by blending the membrane in Trypticase Soy Broth before incubation. Filter-sterilized isopropyl myristate is shown to be less toxic to microorganisms than heat-sterilized isopropyl myristate. The isopropyl myristate method is more sensitive than the polyethylene glycol-ether method for the detection of microbial contamination. PMID:4991924

  1. IL-33 exacerbates liver sterile inflammation by amplifying neutrophil extracellular trap formation.

    PubMed

    Yazdani, Hamza O; Chen, Hui-Wei; Tohme, Samer; Tai, Sheng; van der Windt, Dirk J; Loughran, Patricia; Rosborough, Brian R; Sud, Vikas; Beer-Stolz, Donna; Turnquist, Heth R; Tsung, Allan; Huang, Hai

    2017-09-21

    Neutrophils and Liver sinusoidal endothelial cells (LSECs) both contribute to sterile inflammatory injury during ischemia/reperfusion (I/R), a well-known liver surgical stress. Interleukin-33 (IL-33) has been shown to drive neutrophil infiltration during inflammatory responses through its receptor ST2. We recently reported that infiltrating neutrophils form neutrophil extracellular traps (NETs), which exacerbate sterile inflammatory injury in liver I/R. Here, we sought to determine the role of IL-33 in NET formation during liver sterile inflammation. Evaluation of IL-33 forming NETs was investigated using partial liver I/R model to generate sterile injury in healthy WT, IL-33 and ST2 knockouts. Serum IL-33 and myeloperoxidase (MPO)-DNA levels were measured in both humans and mice after the first surgery. Liver damage was assessed. Mouse neutrophil depletion was performed by intraperitoneal injection of anti-Ly6G antibody before I/R. Patients undergoing liver resection show a significant increase in serum IL-33 compared to healthy volunteers. This coincided with higher serum - MPO-DNA complexes. NET formation was decreased in IL-33KO and ST2 KO mice compared with control after liver I/R. IL-33 or ST2 deficiency protected livers from I/R injury, whereas rIL-33 administration during I/R exacerbated hepatotoxicity and systemic inflammation. In vitro, IL-33 is released from LSECs to promote NET formation. IL-33 deficient LSECs failed to induce NETs. ST2 deficient neutrophils limited their capacity to form NETs in vitro and adoptive transfer of ST2 KO neutrophils to neutrophil-depleted WT mice significantly decreased NET formation. Data establish that IL-33, mainly released from LSECs, causes excessive sterile inflammation after hepatic I/R by inducing NET formation. Therapeutic targeting IL-33/ST2 might extend novel strategies to minimize organ damage in various clinical settings that are associated with sterile inflammation. Liver ischemia and reperfusion injury

  2. Aeration time following ethylene oxide sterilization for reusable rigid sterilization containers: concentration of gaseous ethylene oxide in containers.

    PubMed

    Nakata, S; Umeshita, K; Ueyama, H; Takashina, M; Noguchi, S; Murata, A; Ochi, T

    2000-01-01

    Because ethylene oxide (EO) gas is toxic to humans, restrictions have been imposed on its use for sterilization, specifying allowable levels of residual EO remaining in sterilized apparatus and materials. However, the aeration time that optimizes the removal of the remaining EO when a rigid sterilizing container is used for a vessel had not been identified. Therefore, polyvinyl chloride, which easily adsorbs EO, was placed in rigid sterilizing containers, and aeration was carried out after 1, 8, 12, 17, and 24 hours. After standard EO sterilization, the EO concentrations remaining in the air in the rigid containers were measured. The results indicate that a period of 17 hours of aeration is appropriate when a rigid sterilizing container is used.

  3. Targeted Gene Silencing to Induce Permanent Sterility

    PubMed Central

    Dissen, Gregory A.; Lomniczi, Alejandro; Boudreau, Ryan L.; Chen, Yong Hong; Davidson, Beverly L.; Ojeda, Sergio R.

    2012-01-01

    Contents A nonsurgical method to induce sterility would be a useful tool to control feral populations of animals. Our laboratories have experience with approaches aimed at targeting brain cells in vivo with vehicles that deliver a payload of either inhibitory RNAs or genes intended to correct cellular dysfunction. A combination/modification of these methods may provide a useful framework for the design of approaches that can be used to sterilize cats and dogs. For this approach to succeed it has to meet several conditions: It needs to target a gene essential for fertility. It must involve a method that can selectively silence the gene of interest. It also needs to deliver the silencing agent via a minimally invasive method. Finally, the silencing effect needs to be sustained for many years, so that expansion of the targeted population can be effectively prevented. In this article we discuss this subject and provide a succinct account of our previous experience with: a) molecular reagents able to disrupt reproductive cyclicity when delivered to regions of the brain involved in the control of reproduction, and b) molecular reagents able to ameliorate neuronal disease when delivered systemically using a novel approach of gene therapy. PMID:22827375

  4. Sterile neutrinos at a Neutrino Factory

    SciTech Connect

    Lopez-Pavon, Jacobo

    2010-03-30

    We study the potential of a Neutrino Factory (NF) to constrain the parameters of the (3+1)-scheme with a O(1)eV{sup 2} largest mass square difference, considering two set-ups: a NF with 50 GeV (20 GeV) stored muons, with two detectors of the Hybrid-MIND type located at L = 3000(4000), 7500 km. We show that the best sensitivity to sterile neutrinos can be achieved through the nu{sub m}u->nu{sub m}u and the nu{sub m}u->nu{sub t}au channels which can constrain theta{sub 34}<=12 deg. (14 deg.) and theta{sub 24}<=7.5 deg. (8 deg.) with the 50 GeV (20 GeV) NF. We also study the CP-violation in this new context showing that the CP-asymmetries in the nu{sub m}u->nu{sub t}au channel can give us the chance to see a clear new CP-violation signal associated with the sterile neutrinos.

  5. Daughters mimic sterile neutrinos (almost!) perfectly

    SciTech Connect

    Hasenkamp, Jasper

    2014-09-01

    Since only recently, cosmological observations are sensitive to hot dark matter (HDM) admixtures with sub-eV mass, m{sub hdm}{sup eff} < eV, that are not fully-thermalised, Δ N{sub eff} < 1. We argue that their almost automatic interpretation as a sterile neutrino species is neither from theoretical nor practical parsimony principles preferred over HDM formed by decay products (daughters) of an out-of-equilibrium particle decay. While daughters mimic sterile neutrinos in N{sub eff} and m{sub hdm}{sup eff}, there are opportunities to assess this possibility in likelihood analyses. Connecting cosmological parameters and moments of momentum distribution functions, we show that—also in the case of mass-degenerate daughters with indistinguishable main physical effects—the mimicry breaks down when the next moment, the skewness, is considered. Predicted differences of order one in the root-mean-squares of absolute momenta are too small for current sensitivities.

  6. Sterile hypopyon secondary to ultrasonic cleaning solution.

    PubMed

    Richburg, F A; Reidy, J J; Apple, D J; Olson, R J

    1986-05-01

    During a 20-week period, 21 cases of sterile hypopyon occurred 24 hours after uncomplicated extracapsular cataract extraction and in-the-bag posterior chamber intraocular lens implantation at the Valley Eye Institute. While all cases responded to steroid treatment and exhibited no residual ocular effects, the cause of the hypopyon remained a mystery despite an on-going reevaluation of the surgical procedure and sterilization techniques. Several suspected causes were investigated and eliminated. It was clinically determined that surgical instruments placed in older ultrasonic cleaning solution caused the hypopyons. Further analysis at the Center for Intraocular Research at the University of Utah revealed that the instruments were contaminated by a heat-stable endotoxin that remained on the instruments through the autoclaving process. Surgeons currently using ultrasonic instrument cleaners should be aware that, with some models, following the manufacturer's recommended fluid changing procedures could result in endotoxic contamination of surgical instruments which could, in turn, cause severe inflammatory reactions in the immediate postoperative period.

  7. Sterile Neutrino Search at the NEOS Experiment

    NASA Astrophysics Data System (ADS)

    Ko, Y. J.; Kim, B. R.; Kim, J. Y.; Han, B. Y.; Jang, C. H.; Jeon, E. J.; Joo, K. K.; Kim, H. J.; Kim, H. S.; Kim, Y. D.; Lee, Jaison; Lee, J. Y.; Lee, M. H.; Oh, Y. M.; Park, H. K.; Park, H. S.; Park, K. S.; Seo, K. M.; Siyeon, Kim; Sun, G. M.; NEOS Collaboration

    2017-03-01

    An experiment to search for light sterile neutrinos is conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search is done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of about 22. The shape of the antineutrino energy spectrum obtained from the eight-month data-taking period is compared with a hypothesis of oscillations due to active-sterile antineutrino mixing. No strong evidence of 3 +1 neutrino oscillation is found. An excess around the 5 MeV prompt energy range is observed as seen in existing longer-baseline experiments. The mixing parameter sin22 θ14 is limited up to less than 0.1 for Δ m412 ranging from 0.2 to 2.3 eV2 with a 90% confidence level.

  8. Sterilization of skin allografts by ionizing radiation.

    PubMed

    Bourroul, Selma Cecília; Herson, Marisa Roma; Pino, Eddy; Matho, Monica Beatriz

    2002-11-01

    The skin has a fundamental role in the viability of human body. In the case of extensive wounds, skin allografts provide an alternative to cover temporarily the damaged areas. After donor screening and preservation in glycerol 85%, the skin can be stored in a Skin Bank. Glycerol at this concentration has a bacteriostatic effect after certain time of preservation. On the other hand, skin sterilization by ionizing radiation may reduce the quarentine period for transplantation in patients. The objective of this work was to evaluate allograft sterilization using two sources of ionizing radiation. Through the analysis of stress-strain, it was intended to verify possible effects of the radiation on the structure of preserved grafts. Three groups of skin samples were selected. The first group was maintained in the initial conditions, not irradiated. The second was exposed to cobalt-60, while the third one was irradiated using an Dynamitron Accelerator JOB188 electron beam. The irradiation dose was 25 kGy for both tests. Both irradiation sources, and the Instron Universal Machine used for biomechanical experiments, are installed at the Centro de Tecnologia das Radiações/Instituto de Pesquisas Energéticas e Nucleares (São Paulo, Brazil). According to the preliminary results, biomechanical characteristics of the samples irradiated seem to be maintained with regard to the non irradiated group.

  9. Sterile Neuroinflammation and Strategies for Therapeutic Intervention

    PubMed Central

    2017-01-01

    Sterile neuroinflammation is essential for the proper brain development and tissue repair. However, uncontrolled neuroinflammation plays a major role in the pathogenesis of various disease processes. The endogenous intracellular molecules so called damage-associated molecular patterns or alarmins or damage signals that are released by activated or necrotic cells are thought to play a crucial role in initiating an immune response. Sterile inflammatory response that occurs in Alzheimer's disease (AD), Parkinson's disease (PD), stroke, hemorrhage, epilepsy, or traumatic brain injury (TBI) creates a vicious cycle of unrestrained inflammation, driving progressive neurodegeneration. Neuroinflammation is a key mechanism in the progression (e.g., AD and PD) or secondary injury development (e.g., stroke, hemorrhage, stress, and TBI) of multiple brain conditions. Hence, it provides an opportunity for the therapeutic intervention to prevent progressive tissue damage and loss of function. The key for developing anti-neuroinflammatory treatment is to minimize the detrimental and neurotoxic effects of inflammation while promoting the beneficial and neurotropic effects, thereby creating ideal conditions for regeneration and repair. This review outlines how inflammation is involved in the pathogenesis of major nonpathogenic neuroinflammatory conditions and discusses the complex response of glial cells to damage signals. In addition, emerging experimental anti-neuroinflammatory drug treatment strategies are discussed. PMID:28127491

  10. Cytoplasmic male sterility in Brassicaceae crops.

    PubMed

    Yamagishi, Hiroshi; Bhat, Shripad R

    2014-05-01

    Brassicaceae crops display strong hybrid vigor, and have long been subject to F1 hybrid breeding. Because the most reliable system of F1 seed production is based on cytoplasmic male sterility (CMS), various types of CMS have been developed and adopted in practice to breed Brassicaceae oil seed and vegetable crops. CMS is a maternally inherited trait encoded in the mitochondrial genome, and the male sterile phenotype arises as a result of interaction of a mitochondrial CMS gene and a nuclear fertility restoring (Rf) gene. Therefore, CMS has been intensively investigated for gaining basic insights into molecular aspects of nuclear-mitochondrial genome interactions and for practical applications in plant breeding. Several CMS genes have been identified by molecular genetic studies, including Ogura CMS from Japanese radish, which is the most extensively studied and most widely used. In this review, we discuss Ogura CMS, and other CMS systems, and the causal mitochondrial genes for CMS. Studies on nuclear Rf genes and the cytoplasmic effects of alien cytoplasm on general crop performance are also reviewed. Finally, some of the unresolved questions about CMS are highlighted.

  11. Sterile antineutrino search in the MINOS experiment

    NASA Astrophysics Data System (ADS)

    Chen, Rui; Minos Collaboration

    2017-01-01

    The MINOS experiment is a long-baseline on-axis neutrino oscillation experiment. The two detectors are separated by 734km and optimised for sensitivity to the disappearance of muon neutrinos and antineutrinos delivered by the NuMI beam at Fermilab. The MINOS detectors are magnetised, giving the experiment a unique ability to separate neutrinos and antineutrinos on an event-by-event basis. Thanks to the different possible NuMI beam configurations, MINOS has accumulated 10 . 56 ×1020 POT from a muon neutrino dominated beam and 3 . 36 ×1020 POT from a muon antineutrino enhanced beam. In this talk I will present an analysis of the muon antineutrino interactions collected in both beam configurations. The LSND and MiniBooNE experiments have observed non-standard electron antineutrino appearance in their oscillation analyses. A possible explanation for this is the 3+1 sterile neutrino model where one adds an additional neutrino to the current three-flavour model. MINOS is sensitive to this model through looking at the charged current neutrino and antineutrino energy spectra to probe any deviations from the three-flavour muon neutrino and antineutrino survival probabilities. In this talk, I will present new limits on sterile antineutrinos, using this 3+1 model.

  12. Working conditions and health effects of ethylene oxide exposure at hospital sterilization sites.

    PubMed

    Sobaszek, A; Hache, J C; Frimat, P; Akakpo, V; Victoire, G; Furon, D

    1999-06-01

    Ethylene oxide (EtO) is a powerful disinfectant and sterilant for heat-sensitive surgical items and instruments. Its use in hospitals constitutes an important source of occupational exposure that is sometimes underestimated, such as in cases of EtO device malfunction when the safety rules of procedure are not strictly followed or when individual or collective protective equipment is lacking. We carried out a descriptive study of the health care workers who were assigned to EtO sterilization units of the Lille University Hospital Centre in Lille, France (n = 16). Before the modification of the sterilization units in the development of a single, central sterilization site, we studied the workplaces, occupational conditions, and work procedures of the health care workers exposed to EtO. The aim was to assess the risk of EtO overexposure of the workers in order to improve workers' health and security in the future sterilization center. The study was based on a physical examination, a questionnaire covering each subject's personal and occupational history, and a complete ocular examination. For occupational conditions, the studies of each workplace were also performed by the occupational physician. Area and personal breathing air samplings were performed at each exposure site. Fourteen of the 16 operators had posterior and anterior subcapsular lens opacities, three of which seemed to be directly and primarily related to occupational exposure; the other ten seemed to be rather common and compatible with age. High levels of EtO exposure were reported in the oldest site (90 parts per million [ppm] during the changing of the gas bottle), where exposure often exceeded French threshold limits (permissible exposure limit: 1 ppm 8-hour time-weighted average (TWA) in air; short-term excursion limit: 5 ppm 15-minute TWA in air), or the current US recommended and legal exposure limits for EtO advocated by the Occupational Safety and Health Administration and the American

  13. Evaluation of steam penetration and sterilization of natural latex wraps.

    PubMed

    Rossanese, Matteo; Gasson, James; Barker, Colin; Bowlt, Kelly

    2014-11-01

    To evaluate the efficacy of steam and ethylene oxide (EtO) sterilization of Vetrap™ bandages. Prospective experimental study. Vetrap™ bandages (n = 70; 35 as supplied by the manufacturer, 35 unwound and tightly rewound). Vetrap™ bandage rolls (n = 60) marked with a 1 cm square were inoculated with 0.1 mL Geobacillus stearothermophilus spores, packaged in a pouch together with independent sterilization indicators and assigned into 3 sub-groups for sterilizer type: dynamic air removal, gravity displacement, and bench-top pre-vacuum and further sub-divided into 2 sterilization temperatures. Vetrap™ bandages rolls (n = 10) were inoculated with 0.1 mL Bacillus atrophaeus spores in the same manner and underwent EtO sterilization. After sterilization, the 1 cm marked square was aseptically resected to the level of the cardboard tube and enriched in a flask containing 10 mL tryptic soy broth for 24 hours at 60°C for G. stearothermophilus and 37°C for B. atrophaeus. Aliquots were subsequently plated on a Petri dish of tryptic soy agar and incubated at 60°C for G. stearothermophilus and 37°C for B. atrophaeus for 24 hours. Samples were scored positive if colonies of indicator organism were present on the nutrient agar after 24 hours. Three Vetrap™ bandages yielded post-sterilization growth of G. stearothermophilus: 2 from the dynamic air removal sterilizer at 134°C for 3.5 minutes, and 1 from the bench-top pre-vacuum sterilizer at 121°C for 15 minutes. After EtO sterilization, no positive samples were detected. Steam sterilization may be incomplete for Vetrap™ bandages whereas EtO showed complete destruction of resistant bacterial spores. © Copyright 2014 by The American College of Veterinary Surgeons.

  14. [Survey of methods of cleaning, decontamination, disinfection and sterilization in dental health services in tropical areas].

    PubMed

    Clapeau, G; Decroix, B; Bakayoko-Ly, R; Varenne, B; Dosso-Hien, D; Decroix, M O

    1997-01-01

    hygiene standards despite difficult practice conditions, exacerbated by supply problems. In all applications, hygiene involves a succession of closely-related, logical steps, which form an asepsis chain aimed at preventing the transmission of infection. Our survey shows that fundamental elements of hygiene require attention to achieve this aim. The cleaning, disinfection and sterilizing of floor surfaces and equipment should be improved and more widespread use made of disposable items. It is important to define the hygiene level required for particular treatments, taking into account the oral and dental micro flora and whether the equipment has been decontaminated, disinfected or sterilized. A piece of equipment is decontaminated if it has been mechanically cleaned and decontaminated. It is disinfected if these steps are followed by rinsing with sterile water, drying and conditioning. An item is described as sterilized if it is cleaned, decontaminated, rinsed, dried, conditioned and then sterilized. We found that a wide variety of chemicals were used to clean hands, surfaces and equipment. The nature and appropriate methods of use of these chemicals were not widely known. Understanding the chemical composition of these chemicals makes it possible to classify them into cleaning agents, detergents, decontaminating agents and disinfectants. The definition, choice and use of antiseptics and disinfectants should be strictly controlled. It is also vital that single-use disposable items are used only once and are never reused. Hygiene in the dental surgery is a chain of processes aimed at protecting the patient and the medical staff. There are many links in the chain, involving floor and surface hygiene, hand washing by dentists and dental assistants, washing of surgery linen and treatment of equipment. Dental practitioners should continually focus on ensuring that the chain of hygiene procedures is not broken, in their own interests as well as in those of their patients.

  15. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Sterilization by hysterectomy. 50.207 Section 50... Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or arrange for the performance of any hysterectomy solely for the purpose of rendering an individual...

  16. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50... Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or arrange for the performance of any hysterectomy solely for the purpose of rendering an individual...

  17. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Sterilization by hysterectomy. 50.207 Section 50... Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or arrange for the performance of any hysterectomy solely for the purpose of rendering an individual...

  18. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Sterilization by hysterectomy. 50.207 Section 50... Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or arrange for the performance of any hysterectomy solely for the purpose of rendering an individual...

  19. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Sterilization by hysterectomy. 50.207 Section 50... Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or arrange for the performance of any hysterectomy solely for the purpose of rendering an individual...

  20. Long-term sterility of orthodontic-surgical appliances.

    PubMed

    Brusca, María I; Nastri, Natalia; Mosca, Christian O; Nastri, María L; Rosa, Alcira C

    2004-01-01

    The aim of this study was to evaluate the long-term sterility of new dental appliances according to the non rigid wrapping employed and assess the effectiveness of sterilization in a steam autoclave at 134 degrees for 20 minutes using physical, chemical, and biological indicators. All the experimental (E) samples and the control samples (C) were assigned to one of three groups according to the type of packaging: paper bag (E1), paper/plastic pouch (E2), nylon tubing bag (E3). Each bag contained standardized orthodontic wires and brackets and sterility indicators. The samples were evaluated at the following experimental times: immediately, and 6, 12, 24 and 30 months post-sterilization. The samples were analyzed under aerobic and anaerobic conditions in keeping with the protocol currently in use at the Department of Microbiology, School of Dentistry, University of Buenos Aires. The group of control, non-sterilized samples (C1, C2, C3) were analyzed prior to the onset of the study, and were found to be contaminated. None of the sterilized samples in any of the three experimental groups evidenced contamination at any of the experimental times. The results showed that, under the present conditions, the packages and orthodontic appliances remained sterile for 30 months. These results show the importance of controlling sterility and the storage conditions over time for all the orthodontic/surgical appliances used in invasive treatments.

  1. Puzzles in modern biology. I. Male sterility, failure reveals design

    PubMed Central

    Frank, Steven A.

    2016-01-01

    Many human males produce dysfunctional sperm. Various plants frequently abort pollen. Hybrid matings often produce sterile males. Widespread male sterility is puzzling. Natural selection prunes reproductive failure. Puzzling failure implies something that we do not understand about how organisms are designed. Solving the puzzle reveals the hidden processes of design. PMID:28004842

  2. [Research on sterilization of pathogens by high electrostatic voltage method].

    PubMed

    Wang, X; Wu, Y; Ni, X; Xia, B; Xu, J; Du, Q

    1992-10-01

    An experimental research has been carried out on the sterilization of four kinds of pathogens by high electrostatic method along with an inquiry into the influence of voltage waveform and the treated time on sterilization. It is concluded that pathogens can be killed efficiently by corona discharge field.

  3. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    USDA-ARS?s Scientific Manuscript database

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  4. Parents' Attitudes toward Sterilization of Their Mentally Retarded Children.

    ERIC Educational Resources Information Center

    Wolf, Lucille; Zarfas, Donald E.

    1982-01-01

    One hundred fifty-seven parents' attitudes toward sterilization and the sexuality of their retarded offspring were identified. Parent and child characteristics associated with these attitudes were investigated. Findings indicated that parents substantially concurred with the principle of sterilization (71 percent for involuntary, 67 percent for…

  5. Sterilization of the Mentally Ill and the Mentally Retarded.

    ERIC Educational Resources Information Center

    National Association of State Mental Health Program Directors, Washington, DC.

    Reported were the results of a survey on the sterilization of the mentally ill and the mentally retarded. Thirty-three states responded to the survey. It was found that 17 states have a sterilization statute, but the existence of the statute was explained not to mean that the procedure was used. Sixteen states responded that they did not have a…

  6. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... monitor adequacy of sterilization. The device consists of a known number of microorganisms, of...

  7. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... monitor adequacy of sterilization. The device consists of a known number of microorganisms, of...

  8. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... monitor adequacy of sterilization. The device consists of a known number of microorganisms, of...

  9. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... monitor adequacy of sterilization. The device consists of a known number of microorganisms, of...

  10. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that...

  11. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that...

  12. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that...

  13. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that...

  14. Irradiation of Anastrepha ludens (Diptera: Tephritidae) revisited: optimizing sterility induction.

    PubMed

    Rull, Juan; Diaz-Fleischer, Francisco; Arredondo, Jose

    2007-08-01

    Irradiation doses currently applied to sterilize Mexican fruit flies, Anastrepha ludens (Loew) (Diptera: Tephritidae), for release under the sterile insect technique eradication campaign in Mexico, were reviewed in an effort to increase sterile male performance in the field. A dose maximizing sterility induction into wild populations was sought by balancing somatic fitness with genetic sterility. Doses of 40, 60, and 80 Gy induced 95% or more sterility in all males, which in turn induced similar degrees of sterility into a cohort of wild flies in the laboratory. However, a low dose of 40 Gy was sufficient to completely suppress egg production in females. Similarly, a mild carryover of genetic damage might have been transferred to the F1 progeny of males irradiated at 40 Gy crossed with fertile wild females. Our results suggest that the 80-Gy dose currently applied in Mexico can be lowered substantially without jeopardizing program goals. This view could be strengthened by comparing performance of males irradiated at different doses under more natural settings. In general, we discuss the value of determining irradiation doses for pest species where females are more radiosensitive than males, by selecting the dose that causes 100% sterility in females.

  15. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Puzzles in modern biology. I. Male sterility, failure reveals design.

    PubMed

    Frank, Steven A

    2016-01-01

    Many human males produce dysfunctional sperm. Various plants frequently abort pollen. Hybrid matings often produce sterile males. Widespread male sterility is puzzling. Natural selection prunes reproductive failure. Puzzling failure implies something that we do not understand about how organisms are designed. Solving the puzzle reveals the hidden processes of design.

  17. Future short-baseline sterile neutrino searches with accelerators

    SciTech Connect

    Spitz, J.

    2015-07-15

    A number of experimental anomalies in neutrino oscillation physics point to the existence of at least one light sterile neutrino. This hypothesis can be precisely tested using neutrinos from reactors, radioactive isotopes, and particle accelerators. The focus of these proceedings is on future dedicated short-baseline sterile neutrino searches using accelerators.

  18. A simple genetic incompatibility causes hybrid male sterility in mimulus.

    PubMed

    Sweigart, Andrea L; Fishman, Lila; Willis, John H

    2006-04-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1-hms2 incompatibility.

  19. A Simple Genetic Incompatibility Causes Hybrid Male Sterility in Mimulus

    PubMed Central

    Sweigart, Andrea L.; Fishman, Lila; Willis, John H.

    2006-01-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1–hms2 incompatibility. PMID:16415357

  20. Sterile devices: A GMP (Good Manufacturing Practices) workshop manual

    NASA Astrophysics Data System (ADS)

    Derision, R.; Lower, A.; Bimonte, R.

    1983-05-01

    The manual, which covers GMPs for sterilization processes, presents model procedures and forms as well as a variety of articles and reprints. It is a compilation of GMP materials that small device firms may find useful in understanding how some manufacturers have successfully compiled with the GMP requirements as they apply to the manufacture of sterile devices.

  1. Sterilization/disinfection: correcting common misconceptions in the office setting.

    PubMed

    Springer, Rachelle

    2002-01-01

    Nurses in office surgical facilities are often responsible for the processing of instruments and supplies for intraoperative use. Decontamination, preparation and packaging, sterilization, monitoring of the sterilization process, and storage are all key elements in infection control. Practices should be continually updated based on the latest research to enable the office surgical facility to provide the patient with the highest quality of care.

  2. Effectiveness of four sterilizing procedures on prophylaxis cups.

    PubMed

    Forgas, L B; Durland, B J; Duncanson, M G; Parker, D E

    1990-12-01

    Though manufactured as a single use, disposable item, prophylaxis (prophy) cups are often cleaned, sterilized or disinfected, and re-used. The purpose of this study was to determine whether 1) sterilization of prophy cups is achieved during routine procedures 2) debris is completely removed after cleaning. Three types of prophy cups (250 of each type) were evaluated. Prophy cups were contaminated with a pumice slurry containing B. stearothermophilus spore. After contamination, cups were distributed equally between ultrasonic or manual cleaning, then further distributed to one of four sterilization procedures: ETO, chemiclave, autoclave, and glutaraldehyde (GLU) immersion (6 3/4 hours). Five cups served as control and were not subjected to sterilization. Additionally, 15 prophy cups were contaminated and immersed in GLU for 10 minutes. Results indicate sterilization may be achieved by all sterilization methods tested. However, recommended disinfection immersion time of 10 minutes for GLU was not effective in achieving adequate disinfection of prophy cups. Photomicrographs indicate debris remains trapped in prophy cups after manual or ultrasonic cleaning. Prophy cup sterilization may be achieved through standard routine sterilization procedures, but remaining debris is likely due to porosity of rubber and configuration of the cups. Time management, cost effectiveness, and sound clinical judgment suggest single use.

  3. Low-temperature sterilization alternatives in the 1990s

    SciTech Connect

    Schneider, P. . Surgical Div.)

    1994-01-01

    Vapor phase hydrogen peroxide, gas plasma, ozone, and peracetic acids have been commercialized as alternative technologies for low-temperature sterilization. None are viewed as a total replacement for ethylene oxide for on-site sterilization of reusable, heat-sensitive medical materials in healthcare facilities.

  4. 7 CFR 305.28 - Kiln sterilization treatment schedule.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.28 Kiln sterilization treatment schedule. T404-b-4 Dry bulb temperature( °F) Wet bulb depression( °F) Percent... 7 Agriculture 5 2010-01-01 2010-01-01 false Kiln sterilization treatment schedule. 305.28...

  5. Lightest sterile neutrino abundance within the νMSM

    NASA Astrophysics Data System (ADS)

    Asaka, Takehiko; Shaposhnikov, Mikhail; Laine, Mikko

    2007-01-01

    We determine the abundance of the lightest (dark matter) sterile neutrinos created in the Early Universe due to active-sterile neutrino transitions from the thermal plasma. Our starting point is the field-theoretic formula for the sterile neutrino production rate, derived in our previous work [JHEP 06(2006)053], which allows to systematically incorporate all relevant effects, and also to analyse various hadronic uncertainties. Our numerical results differ moderately from previous computations in the literature, and lead to an absolute upper bound on the mixing angles of the dark matter sterile neutrino. Comparing this bound with existing astrophysical X-ray constraints, we find that the Dodelson-Widrow scenario, which proposes sterile neutrinos generated by active-sterile neutrino transitions to be the sole source of dark matter, is only possible for sterile neutrino masses lighter than 3.5 keV (6 keV if all hadronic uncertainties are pushed in one direction and the most stringent X-ray bounds are relaxed by a factor of two). This upper bound may conflict with a lower bound from structure formation, but a definitive conclusion necessitates numerical simulations with the non-equilibrium momentum distribution function that we derive. If other production mechanisms are also operative, no upper bound on the sterile neutrino mass can be established.

  6. Cosmological and Astrophysical Implications of Sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Abazajian, Kevork

    2014-03-01

    Cosmology has entered an even more precision-driven epoch, with many of the basic parameters of cosmology being known to the few-percent level. However, some unresolved tensions remain between large scale structure measures of cosmology and primary cosmic microwave background measures. This may indicate new physics in the neutrino sector, since neutrinos are the second most abundant particle in the Universe, and the least quantified. New neutrino physics may include extra (sterile) species of neutrinos, massive neutrinos, or both. I will review the status of these measures as well as the prospects for the resolution of the tension(s). Neutrinos also play a dominant energetics role in Type II supernova explosions, and the presence of new neutrino physics also has implications for supernova physics, which I will also review. Supported in part by the NSF CAREER Program.

  7. Pressure-assisted thermal sterilization of soup

    NASA Astrophysics Data System (ADS)

    Shibeshi, Kidane; Farid, Mohammed M.

    2010-12-01

    The overall efficiency of an existing scale-up pressure-assisted thermal sterilization (PATS) unit was investigated with regards to inactivation of Geobacillus stearothermophilus spores suspended in pumpkin soup. The PATS unit is a double pipe heat exchanger in which the soup is pumped into its inner high pressure tube and constrained by two high pressure valves, while steam is continuously passed through the annular region to heat the content. The technology is based on pressure generation by thermal expansion of the liquid in an enclosure. In this work, the addition of an air line to push the treated liquid food out of the existing PATS unit has improved the overall quality of the treated samples, as evidenced by achieving higher log reduction of the spores. Compared with thermal processing, the application of PATS shows the potential for lowering the thermal treatment temperature, offering improved food quality.

  8. Twenty years of radiation sterilization in Croatia

    NASA Astrophysics Data System (ADS)

    Ražem, Dus̆an

    2004-09-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m 3 kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m 3 kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made.

  9. Radiation treatment for sterilization of packaging materials

    NASA Astrophysics Data System (ADS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-08-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology.

  10. Sterilization effects of atmospheric cold plasma brush

    NASA Astrophysics Data System (ADS)

    Yu, Q. S.; Huang, C.; Hsieh, F.-H.; Huff, H.; Duan, Yixiang

    2006-01-01

    This study investigated the sterilization effects of a brush-shaped plasma created at one atmospheric pressure. A population of 1.0×104-1.0×105 Escherichia coli or Micrococcus luteus bacteria was seeded in filter paper media and then subjected to Ar and/or Ar +O2 plasmas. A complete kill of the Micrococcus luteus required about 3 min argon plasma exposures. With oxygen addition into the argon plasma gas streams, a complete kill of the bacteria needed only less than 1 min plasma exposure for Micrococcus luteus and about 2 min exposure for Escherichia coli. The plasma treatment effects on the different bacteria cell structures were examined using scanning electron microscopy.

  11. Sterilization effects of atmospheric cold plasma brush

    SciTech Connect

    Yu, Q.S.; Huang, C.; Hsieh, F.-H.; Huff, H.; Duan Yixiang

    2006-01-02

    This study investigated the sterilization effects of a brush-shaped plasma created at one atmospheric pressure. A population of 1.0x10{sup 4}-1.0x10{sup 5} Escherichia coli or Micrococcus luteus bacteria was seeded in filter paper media and then subjected to Ar and/or Ar+O{sub 2} plasmas. A complete kill of the Micrococcus luteus required about 3 min argon plasma exposures. With oxygen addition into the argon plasma gas streams, a complete kill of the bacteria needed only less than 1 min plasma exposure for Micrococcus luteus and about 2 min exposure for Escherichia coli. The plasma treatment effects on the different bacteria cell structures were examined using scanning electron microscopy.

  12. [The psychosocial background of sterile patients].

    PubMed

    Pusch, H H; Urdl, W; Walcher, W

    1989-01-01

    The psychosocial background of 300 childless couples from the Infertility Clinic of the Department of Gynecology and Obstetrics, University of Graz, was evaluated by means of a questionnaire and statistical analysis of data from their files. Points of special interest were problems such as interactions of the couple, motivations for the desire of children, psychosomatics, andrological investigation within the gynecological department, sexual habits and motivation and compliance concerning investigations and treatment. 72% of the questionnaires were returned. 50% of the sterile couples preferred to attend the infertility clinic together. 26% felt restrictions in their sexual behaviour due to the unrealized desire of children, 48% expected improvements in their partnership if they could have children. Compliance of male partners concerning the regular intake of prescribed medicaments was 83%, 63% accepted to stop smoking in cases of pathospermia.

  13. Stabilization of methacrylic polymers against sterilizing radiation

    SciTech Connect

    Keating, P.J.; Roach, D.E.

    1992-04-07

    This patent describes a method for preparing a polymer with improved resistance to sterilizing radiation. It comprises preparing a polymer comprising at least 50% of units derived from one or more alkyl methacrylates and, optionally, units derived from one or more other monomers selected from vinyl or vinylidene monomers; admixing the polymer with from about one-half to about two percent by weight of the monomers of at least one aliphatic alcohol, the alcohol containing up to ten carbon atoms, no ultraviolet stabilizer being present, so as to distribute the alcohol essentially uniformly throughout the polymer, wherein an impact modifier is admixed with the polymer prior to admixing the at least one alcohol.

  14. Post-sterilization autonomy among young mothers in South India.

    PubMed

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  15. Color stability of shade guides after autoclave sterilization.

    PubMed

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  16. Safe use of chemicals for sterilization in healthcare.

    PubMed

    Warburton, P Richard

    2012-01-01

    Chemical sterilization is necessary for temperature sensitive items that cannot be sterilized with steam. These chemical sterilants are by their nature hazardous; otherwise, they would not function well. Modern sterilizers and associated equipment are designed so that these chemicals can be used safely. Whether through mechanical failure, wear and tear, or user error, leaks do sometimes occur. The maximum chemical exposure is determined by OSHA permissible exposure limits, if available, and if not available, employers should use recognized standards. Employers have a duty to ensure safe work environment and take appropriate action to mitigate potential risks. Employers should therefore assess the hazards of the chemicals used, the potential modes for leakage, means for identifying leaks and the risk of exposure of employees. Ideally, work practices should be developed by healthcare facilities so that sterile processing employees know what to do in case of a chemical leak or spill, and how to safely use these chemicals to ensure their own, and patient safety.

  17. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, Charles E.

    1999-02-09

    A method for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process.

  18. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, C.E.

    1999-02-09

    A method is described for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process. 2 figs.

  19. Evaluation of single-use reprocessed laparoscopic instrument sterilization.

    PubMed

    Lopes, Cristiane de Lion Botero Couto; Graziano, Kazuko Uchikawa; Pinto, Terezinha de Jesus Andreoli

    2011-01-01

    This experimental, comparative, laboratory study evaluated the effectiveness of the sterilization of single-use laparoscopic instruments--SULIs (grasper, dissector, scissors, Veress needle and electrosurgical probe system), after contamination-challenge with bacterial spores and sheep blood, and compared the results of the sterilization tests with those of the equivalent reusable instruments. The cleaning methods used were; ultrasonic washer with pulsatile water jet and enzymatic detergent, manual cleaning, cleaning with pressurized water and rinsing. The SULIs were sterilized with ethylene oxide and the reusable instruments in an autoclave. Sterility tests showed 100% negative results for recovery of contaminate microorganisms in both groups. It was concluded that, regarding the sterilization, that it is possible to reprocess SULIs.

  20. Cutaneous sterile granulomas/pyogranulomas, leishmaniasis and mycobacterial infections.

    PubMed

    Santoro, D; Prisco, M; Ciaramella, P

    2008-11-01

    Cutaneous "sterile" granulomas represent a group of uncommon skin disorders of unknown aetiopathogenesis. Many diseases are included in this group (for example, sterile granuloma/pyogranuloma syndrome and reactive histiocytosis). The definition of sterile is based on the exclusion of other possible aetiological agents (for example, microorganisms or foreign body). Many techniques are used to rule out a microbial aetiology including cytology, histology, immunohistochemistry and culture. However, some organisms are "fastidious" and difficult to culture or to identify with routine methods, and molecular studies are necessary. This is particularly true for mycobacteria (for example, canine leproid granuloma syndrome) and Leishmania. Recently, studies in human and veterinary medicine have proved the presence of microorganisms (mycobacteria and Leishmania) using a polymerase chain reaction technique in specimens previously diagnosed as sterile. Therefore, it is very important, with the development of new technologies, to use a multidisciplinary diagnostic approach to definitively rule out any microorganism before declaring a disease sterile.

  1. Ethylene oxide sterilization of medical devices: a review.

    PubMed

    Mendes, Gisela C C; Brandão, Teresa R S; Silva, Cristina L M

    2007-11-01

    Ethylene oxide (EO) is a well-known sterilizing agent. However, only recently has its use significantly emerged, based on its range of applications in the field of new medical device development and sterilization. This paper describes the progress in terms of EO sterilization and concludes that it remains a promising field to explore and develop. The EO action mechanism and toxicity are analyzed, and a critical analysis is made on how it is possible to use EO sterilization for medical devices advantageously, with emphasis on cycle design and validation. One huge challenge is related with the development of mathematical models to integrate lethality to allow a continuous increase of process flexibility, without compromising its safety. The scientific community should also focus on other important issues, such as EO diffusion in different substrates, taking into account different environmental conditions both for sterilization and aeration.

  2. Microwave sterilization of nitrous oxide nasal hoods contaminated with virus

    SciTech Connect

    Young, S.K.; Graves, D.C.; Rohrer, M.D.; Bulard, R.A.

    1985-12-01

    Although there exists a desire to eliminate the possibility of cross-infection from microbial contaminated nitrous oxide nasal hoods, effective and practical methods of sterilization in a dental office are unsatisfactory. Microwaves have been used to sterilize certain contaminated dental instruments without damage. In this study nasal hoods contaminated with rhinovirus, parainfluenza virus, adenovirus, and herpes simplex virus were sterilized in a modified microwave oven. Ninety-five percent of the virus activity was destroyed after 1 minute of exposure of the contaminated nasal hoods to microwaves. By the end of 4 minutes, complete inactivation of all four viruses was found. Repeated exposure of the nasal hoods to microwaves resulted in no damage to their texture and flexibility. Microwave sterilization may potentially provide a simple and practical method of sterilizing nitrous oxide anesthesia equipment in a dental or medical practice.

  3. Sterilization of fermentation vessels by ethanol/water mixtures

    SciTech Connect

    Wyman, C.E.

    1991-03-20

    This invention is comprised of a method for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process.

  4. [Mechanisms of urinary tract sterility maintenance].

    PubMed

    Okrągła, Emilia; Szychowska, Katarzyna; Wolska, Lidia

    2014-06-02

    Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system's action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI) are women (an additional risk factor is pregnancy), but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS), fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  5. Sterile working in ultrasonography: the use of dedicated ultrasound covers and sterile ultrasound gel.

    PubMed

    Marhofer, Peter; Fritsch, Gerhard

    2015-01-01

    Ultrasound is currently an important tool for diagnostic and interventional procedures. Ultrasound imaging provides significant advantages as compared to other imaging methods. The widespread use of ultrasound also carries the risk of drawbacks such as cross-infections. A large body of literature reports this possibly life-threatening side effect and specific patient populations are particularly at risk (e.g., neonates). Various methods of ultrasound probe disinfection are described; however, none of the mechanical or chemical probe disinfection procedures is optimal and, in particular, disinfection with high concentration of alcohol might be associated with ultrasound probe damage. The preparation of ultrasound probes with dedicated probe covers is a useful alternative for sterile working conditions. One ultrasound probe cover discussed in this paper is directly glued on to the ultrasound probe without the use of ultrasound coupling gel. By the use of sterile ultrasound coupling gel at the outer surface, additional effects on aseptic working conditions can be obtained.

  6. Development of ozone sterilization system based microcontroller for E. Coli bacteria sterilization

    NASA Astrophysics Data System (ADS)

    Eko Fahrudin, Arfan; Endarko; Vijai Nasrulloh, Amar; Sari, Nurma

    2017-05-01

    It has been created microcontroller-based ozone sterilization system which is used for E. Coli bacteria sterilization. The created system consists of a neon sign transformer, corona electrode, ozone gas chamber container and ozone gas metering systems. Neon sign transformer and corona electrode are then assembled into an ozone generator that works on the principle of corona discharge. The use of ozone generators is controlled by microcontroller system. Ozone gas is produced by ozone generators which housed in a chamber and equipped by ozone gas indicator. The results of ozone gas effect testing in E. Coli with varied exposure of 15, 30 and 45 minutes showed the decrease number of E. Coli colonies of tested bacteria samples compared to the control sample without ozone gas exposure.

  7. Instrument integrity and sterility: the perioperative practitioner's responsibilities.

    PubMed

    Gilmour, Diane

    2008-07-01

    Surgical instruments, whether single use or reusable, are defined by the University of Newcastle's Online Medical Dictionary as 'Hand held tools or implements used by health professionals for the performance of surgical tasks' (CancerWEB 1998). This definition, in its broadest terms, recognises that the inter-professional team (health professionals) are involved in the use, care and management of that tool or implement (performance of surgical tasks). Spry (2007) identifies that a surgical instrument could last 10 years if well made, carefully handled and appropriately used and that it is the responsibility of the surgical team and sterile services personnel to preserve and protect the life of each individual instrument. This article will identify the perioperative practitioner's responsibility in ensuring that each surgical instrument is fit for purpose, safe for use and will not harm the patient during use. The article will outline the process of instrument/set selection and the pre-, intra- and postoperative checks that should be made by the inter-professional team prior to, during and after use of that set/instrument. This article will also enable the practitioner to gain or reinforce their knowledge and understanding of the decontamination process and its application within the perioperative environment.

  8. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    SciTech Connect

    Parker, A.

    2007-03-15

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [Spanish] La tecnica de insecto esteril (TIE) es una tecnologia de control de plagas favorable para el medio ambiente con una aplicacion de un control integrado de plagas claves para toda la area, incluyendo la supresion o eliminacion de poblaciones introducidas y la exclusion de nuevas introducciones. La esterilidad reproductiva es normalmente inducida por radiacion ionizada, un metodo conveniente y consistente que mantiene un grado razonable para la capacidad de competencia en insectos liberados. El costo y la eficacia de un programa de control que incluye TIE dependen en tener un balance entre la esterilidad y la capacidad para competir, pero parece que los programas operacionales corrientes con TIS como un componente no estan logrando el tener un balance apropiado. En esta publicacion, nosotros discutimos la optimizacion del proceso de esterilizacion y presentamos un modelo y procedimiento sencillos para determinar la dosis optima. (author)

  9. An investigation of sterile immunity against toxoplasmosis in rats.

    PubMed

    Freyre, A; Falcón, J; Mendez, J; Correa, O; Morgades, D; Rodríguez, A

    2004-01-01

    The non-persistent BK strain was examined for its ability to induce sterile immunity in Wistar rats. Groups of 2-9 Wistar rats were inoculated subcutaneously with 5 x 10(4) BK strain tachyzoites per rat. Two months later, 46 rats were dosed by gavage with 2 x 10(1) cysts of the C, ME-49, Prugniaud, C-56, Elg, M-7741 or M3 strains. Another 26 rats were inoculated with 10(3) oocysts of the ME49, M7741, Bear or Hopa-Hopa strains of Toxoplasma gondii. After 2 months, the rats were euthanized and their brains screened microscopically for toxoplasma tissue cysts and bioassayed in mice if negative. As judged by bioassay, the BK strain of Toxoplasma induced statistically significant protection against reinfection only when rats were challenged with cysts of the C and Prugniaud strains or with oocysts of the ME49 strain. Nonetheless, cysts were detected microscopically only in 23% of brains of immunized rats challenged with oocysts of the Bear and Hopa-Hopa strains of Toxoplasma and none of those challenged with tissue cysts of any strain. Tissue cysts were detected in 43 and 48% of non-immunized control rats infected with tissue cysts and oocysts, respectively. The overall infection in control rats (microscopy and bioassay) was 70 and 72% for rats inoculated with cysts and oocysts, respectively. These results are consistent with the divergent results obtained by other investigators with regard to protection after challenge with different complete strains (cyst and oocysts forming) of the parasite, of rats immunized with incomplete strains.

  10. Cross-clade immunity in cats vaccinated with a canarypox-vectored avian influenza vaccine

    USDA-ARS?s Scientific Manuscript database

    Several felid species have been shown to be susceptible to infection with highly pathogenic avian influenza (HPAI) viruses of the H5N1 subtype. Infection of felids by H5N1 HPAI virus is often fatal, and cat-to-cat transmission has been documented. Domestic cats may then be involved in the transmis...

  11. What do you mean you can't sterilize it? The reusable medical device matrix.

    PubMed

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    begins with proper cleaning and processing of the surgical instruments. Surgical site infections can increase the length of stay and the cost of the patients' hospitalization, as well as increased risk, morbidity and even mortality. 1 Today's patients are far more informed than they were in the past. They can gather information from the internet as well as from television, radio, and print media. This knowledge empowers the patient to expect that their healthcare providers are practicing due diligence. It is the ethical duty and responsibility of nurses to provide safe, competent care while protecting the rights of the patient and being accountable to the professional governing bodies. In other words, we are advocates for both our patients and the healthcare system.2 Using both new and innovative instruments in the OR was, in the past, as simple as a surgeon requesting an instrument, the perioperative nurse ordering the instrument and CPD processing it for use in the OR. That is no longer the case. With a wide range of more complex instrumentation and an increasing focus on sterilization strategies, healthcare facilities have had to adopt a more rigorous approach. There are many challenges in the world of sterile processing. A common one, faced on a regular basis, is the provision of vague, inaccurate reprocessing recommendations from the medical device manufacturer. Canadian centres are not able to meet European standards for reprocessing. European cycles, often referred to as "Fractionated Steam Cycles", are different than the pre-vacuum steam cycles run in Canada.

  12. Sterile, injectable cyclodextrin nanoparticles: effects of gamma irradiation and autoclaving.

    PubMed

    Memisoglu-Bilensoy, Erem; Hincal, A Atilla

    2006-03-27

    Sterility is required as stated by compendial requirements and registration authorities worldwide for an injectable drug carrier system. In this study, injectable nanospheres and nanocapsules prepared from amphiphilic beta-cyclodextrin, beta-CDC6, were assessed for their in vitro properties such as particle size distribution, zeta potential, nanoparticle yield (%), drug entrapment efficiency and in vitro drug release profiles. Different sterilization techniques such as gamma irradiation and autoclaving were evaluated for their feasibility regarding the maintenance of the above mentioned nanoparticle properties after sterilization. It was found that amount these techniques, sterilization with gamma irradiation seemed to be the most appropriate technique with no effect on particle size, drug loading and drug release properties. Gamma irradiation causes some chemical changes on beta-CDC6 observed as changes in zeta potential but this does not lead to any significant changes for nanoparticle properties. Autoclaving caused massive aggregation for the nanoparticles followed by precipitation, which led to the conclusion that excessive heat disrupted nanoparticle integrity. Sterile filtration was not feasible since nanoparticle sizes were larger than the filter pore size and the yield after sterilization was very low. Thus, it can be concluded that blank and drug loaded beta-CDC6 nanospheres and nanocapsules are capable of being sterilized by gamma irradiation.

  13. Effects of sterilization on the Tekscan digital pressure sensor.

    PubMed

    Agins, Howard J; Harder, Valerie S; Lautenschlager, Eugene P; Kudrna, James C

    2003-11-01

    Investigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applied load of 2225 N (500 lb) was assessed. Simultaneously, 10 un-sterilized sensor arrays, designated Control, were assessed. Each array was loaded 10 times inside a two-dimensional curved surface, and all arrays exhibited high reproducibility (coefficients of variation<2.0%). Following sterilization, the Experimental sensors showed a 22.2% average decrease in recorded force, a statistically significant difference from the pre-sterile data (p<0.002). However, when the Experimental sensors were re-calibrated post-sterilization, they showed only a 0.1% average decrease in recorded force, not a statistically significant difference (p>0.05, beta<0.05). Following 1-week storage, trial 2 data of the Control sensors showed a less dramatic yet significant 3.4% average decrease in recorded force when compared to trial 1 data (p<0.02). Control trial 2, once re-calibrated, showed a 0.5% average decrease in recorded force, not a statistically significant difference (p>0.05, beta<0.05). Results suggest that, following EtO sterilization, accurate and reproducible pressure measurements can be obtained from K-Scan sensors when calibration is performed at time of use.

  14. Maintenance of sterility in 1-mL polypropylene syringes.

    PubMed

    Gonzalez, Serafin; Miller, Darlene; Murphy, Steven P

    2007-09-15

    The sterility of syringes filled with a growth-promoting broth when stored under various temperature conditions was studied. Samples of tryptic soy broth (TSB) were injected into 150 1-mL polypropylene syringes and incubated at 33-37 degrees C for 14 days, after which time they were visually inspected for microbial contamination. In addition to visual inspection, the sterility of all syringes was tested by inoculating samples into 10-mL tubes of thioglycollate broth, incubating at 35 degrees C, and observing for growth for 5 days. After the 14-day incubation period, 30 syringes were removed for sterility validation and microbial growth promotion. TSB from 15 syringes was transferred into sterile culture tubes and challenged with Staphylococcus aureus, Escherichia coli, Bacillus cereus, Candida albicans, and Aspergillus niger. The remaining 120 syringes were repackaged and stored at room temperature (22 degrees C), in a refrigerator (5 degrees C), or in a freezer (-20 degrees C). The sterility of the samples was evaluated at 30 days, 45 days, three months, and six months. No microbial growth was detected by visual inspection in any of the 15 syringes examined for turbidity during validation testing. All study syringes (n = 120) remained sterile throughout the respective evaluation periods, regardless of storage condition. Growth-promoting broth stored in 1-mL polypropylene syringes remained sterile when stored at room temperature, in a refrigerator, or in a freezer for six months.

  15. Male sterility in triploid dandelions: asexual females vs. asexual hermaphrodites.

    PubMed

    Meirmans, P G; Den Nijs, J C M; Van Tienderen, P H

    2006-01-01

    Male reproductive output, pollen in plants and sperm in animals has been shown to constitute a substantial cost for many organisms. In parthenogenetic hermaphrodites, selection is therefore expected to reduce the allocation of resources to male reproductive output. However, sustained production of pollen or sperm has been observed in numerous asexual hermaphrodites. We studied the widespread production of pollen by triploid asexual dandelions, Taraxacum sect. Ruderalia, comparing rare male sterile individuals with pollen producing asexuals. We found that individuals can show plasticity in the production of pollen, but that it is nevertheless possible to distinguish between (facultatively) male sterile asexuals and male fertile asexuals. Based on evidence from genetic markers and crosses, we conclude that the male sterility in asexual dandelions is caused by nuclear genes, in contrast to the cytoplasmically inherited male sterility previously found in sexual dandelions. Male sterile lineages did not produce more seeds per flower head, heavier seeds or seeds that were more viable. However, male sterile plants did produce more seed heads and hence more seeds than pollen producing ones, indicating that they were able to reallocate resources toward seed production. Considering the difference in seed production, it remains puzzling that not more asexual dandelions are male sterile.

  16. [Spontaneous pregnancy, independent of treatment, in sterile couples].

    PubMed

    Bustos López, H H; Villanueva Diaz, C; Garza Rios, P; Gaona, R; Kably Ambe, A

    1993-03-01

    The spontaneous pregnancy independent of treatment in sterility is a frequently observed event in this group of couples. The spontaneous pregnancy appears up to 61% of women with antecedents of sterility and in selected populations of healthy women; a third of them experience, once in their lives a subfertility episode. The characterization of this event in a population with sterility, will help to define the capacity of different diagnostic methods, as well as therapeutic methods in terms of efficacy. The objective of this study was to identify women with diagnosis of sterility and spontaneous pregnancy; to describe the main characteristics: clinical, of laboratory, of gabinet, and to discuss some implications of biological variability useful in the interpretation of these tests. One hundred and eleven patients with sterility and spontaneous pregnancy, in a descriptive and retrospective design, were analyzed. Operational definitions for the main factors related with sterility, were used, as tuboperitoneal, endocrine-ovarian, cervico-vaginal and masculine. The pregnant patients related to any type of treatment, were excluded. Two study groups were established: Group I (n-46) and Group II (n = 65) with primary sterility and secondary sterility, respectively. Average age for both groups was similar (mean = 29 years old). The time of sterility was 46.52 and 43.52 months, for Group I and II, respectively. The time of pregnancy from the point zero (admission), was, in average 6.21 and 4.9 months for Group I and II. The following factors were identified as abnormal: endocrine-ovarian 28.60 by menstrual pattern, progesterone and endometrial biopsy: tuboperitoneal 12.67% by hysterosalpingography and laparoscopy; masculine 12.67 by direct spermatobioscopy.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Neutron-based sterilization of anthrax contamination.

    PubMed

    Liu, Bin; Wang, Qingfei

    2006-05-01

    With the anthrax threat becoming a reality, it is very important to have an effective way to sterilize areas contaminated by anthrax. Anthrax spores are the dormant form of the anthrax bacteria. They can germinate in tissues, producing new bacteria that release lethal toxins. Neutrons can be a powerful tool in our defense against anthrax contamination. Neutrons are elementary particles that have no charge, which allows them to be very penetrating, killing the anthrax spores on the surface and inside the containers. So neutrons have an advantage over other forms of radiation if deep penetration is required to kill biological organisms. A Cf neutron source allows for a low cost method of decontamination. It emits most neutrons in the 100 keV to 2 MeV energy regions, and a neutron in this energy region is 20 times more deadly than electrons or gamma rays in killing anthrax spores. If we just consider the first neutron collision with anthrax spores and that all the anthrax spores will not survive at the dose level above 2.0 x 10 Gy, our calculations show that a 0.5-g Cf neutron source within 20 min can generate 1.11 x 10 m fluence neutrons, which is good enough to kill the anthrax spores on the sample. An experimental confirmation of the above results may prove that to achieve 1.11 x 10 m fluence neutrons on the anthrax spore sample, the neutron irradiation time may be reduced dramatically or the Cf neutron source reduced to 0.1 g level or even less. The aim of this paper is to evaluate a feasible way to sterilize the anthrax contamination by using a Cf neutron source. Presently, we are mainly concentrating on the theoretical estimation of neutron fluence to see if the Cf neutron source can deliver enough neutron irradiation dose to kill the anthrax spores. Our future work will focus on experimental confirmation and Monte Carlo simulation by using Geant4 or MCNP codes. At that time, we will consider the effects of the real experimental setup, the shielding materials

  18. Combined laparoscopic sterilization and pregnancy termination.

    PubMed

    Courey, N G; Cunanan, R G

    1973-06-01

    This is a report of 306 dilation and suction curettage abortions combined with laparoscopic tubal ligations over a 2 1/2 year period. Patients' ages ranged from 21 to 44 years. All were multigravida and in the first trimester of their current pregnancy. 61 had undergone previous abdominal surgery. Average hospital stay was 1 day. Patients are preferably admitted the night before so a laminaria digitata tent can be placed to dilate the cervix. General anesthesia is used and occasionally the patient is intubated if conditions indicate. Insulated instruments are sterilized for 30 minutes in a solution of aqueous cidex or activated dialdehyde. After the area is prepared with Betadine, Hegar cervical dilators are used to dilate the cervix 1 size larger than the suction curette. Care needs to be exercised in making traction on the cervix at the time the dilator is introduced. Berkley suction apparatus is used with negative pressure of 60-70 mm of mercury. Manipulation of the suction curette to reach all areas is required. Blood loss is usually 50-200 ml. This may be minimized by adding Pitocin or Syntocinon to the anesthetic solution. A single-tooth tenaculum and a tubal insufflation cannula control the uterus during the subsequent sterilization procedure. The Verres cannula is inserted paraumbilically and 2.5-3 liters of carbon dioxide injected into the peritoneal cavity. Over distention is to be avoided. A second smaller cannula is inserted. The Palmer biopsy tong is inserted. Each tube is manipulated, grasped, coagulated, severed, and a biopsy taken. Care must be taken not to touch the tip of the tongs to the trocar sleeve. After checking the area the instruments are withdrawn and the carbon dioxide allowed to escape. Incisions are approximated with adhesive bandages. The patient may be discharged 3 to 6 hours after operation. Postoperative hysterosalpingograms on 14 of the 306 women showed no tubal potency in 13 at 8 months after surgery. Tubal peritoneal fistulas

  19. The bladder is not sterile: History and current discoveries on the urinary microbiome.

    PubMed

    Thomas-White, Krystal; Brady, Megan; Wolfe, Alan J; Mueller, Elizabeth R

    2016-03-01

    In the human body, there are 10 bacterial cells for every one human cell. This fact highlights the importance of the National institutes of Health's initiative to map the human microbiome. The Human Microbiome Project was the first large-scale mapping of the human microbiome of 5 body sites: GI tract, mouth, vagina, skin and nasal cavity using culture-independent methods. The bladder was not originally tested because it was considered to be sterile and there were complexities regarding sample collection. Over the last couple years our team along with other investigators have shown that a urinary microbiome exists and for most individuals it plays a protective role.

  20. Using simulation to design a central sterilization department.

    PubMed

    Lin, Feng; Lawley, Mark; Spry, Charlie; McCarthy, Kelly; Coyle-Rogers, Patricia G; Yih, Yuehwern

    2008-10-01

    A simulation project was performed to assist with redesign of the surgery department of a large tertiary hospital and to help administrators make the best decisions about relocating, staffing, and equipping the central sterilization department. A simulation model was created to analyze department configurations, staff schedules, equipment capacities, and cart-washing requirements. Performance measures examined include tray turnaround time, surgery-delay rate, and work-in-process levels. The analysis provides significant insight into how the proposed system will perform, allowing planning for expected patient volume increases. This work illustrates how simulation can facilitate the design of a central sterilization department and improve surgical sterilization operations.