Sample records for sterilization

  1. Reliability of laparoscopic compared with hysteroscopic sterilization at 1 year: a decision analysis.

    PubMed

    Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J

    2011-08-01

    To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.

  2. [Sterilization effect analysis of B-class pulsation table top vacuum sterilizer to dental handpieces].

    PubMed

    Zeng, Shu-Rong; Jiang, Bo; Xiao, Xiao-Rong

    2007-06-01

    Discuss sterilization effect of B-class pulsation table top vacuum pressure steam sterilizer for dental handpiece. Analysis selection of sterilizer for dental handpiece and sterilization management processes and sterilization effect monitoring, evaluation of monitoring result and effective sterilization method. The B-class pulsation table top vacuum pressure steam sterilizer to dental handpiece in West China Stomatological Hospital of Sichuan University met the requirement of the chemical and biological monitoring. Its efficiency of sterilization was 100%. The results of aerobic culture, anaerobic culture, B-type hepatitis mark monitoring to sterilized dental handpiece were negative. It is effective method for dental handpiece sterilization to use B-class pulsation table top vacuum pressure steam sterilizer.

  3. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study.

    PubMed

    Venkatasubramanian, R; Das, U M; Bhatnagar, S

    2010-01-01

    Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde) and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  4. Review of surface steam sterilization for validation purposes.

    PubMed

    van Doornmalen, Joost; Kopinga, Klaas

    2008-03-01

    Sterilization is an essential step in the process of producing sterile medical devices. To guarantee sterility, the process of sterilization must be validated. Because there is no direct way to measure sterility, the techniques applied to validate the sterilization process are based on statistical principles. Steam sterilization is the most frequently applied sterilization method worldwide and can be validated either by indicators (chemical or biological) or physical measurements. The steam sterilization conditions are described in the literature. Starting from these conditions, criteria for the validation of steam sterilization are derived and can be described in terms of physical parameters. Physical validation of steam sterilization appears to be an adequate and efficient validation method that could be considered as an alternative for indicator validation. Moreover, physical validation can be used for effective troubleshooting in steam sterilizing processes.

  5. Sterilization in Finland: from eugenics to contraception.

    PubMed

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  6. The sterilization of endodontic hand files.

    PubMed

    Hurtt, C A; Rossman, L E

    1996-06-01

    Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments.

  7. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  8. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    PubMed Central

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  9. Sterilization of slide sheath anesthetic injection systems placed within sharps containers.

    PubMed

    Palenik, C J; Burke, F J; Bose, M; Altweis, M L

    1997-01-01

    The purpose of this study was to evaluate the effect that two steam autoclaves and an unsaturated chemical vapor sterilizer had on killing bacterial endospores present on commercial spore strips or applied to sterile anesthetic injection systems placed within sharps containers. Three types of sterilizers were used: a gravity steam autoclave, a high vacuum steam autoclave and an unsaturated chemical vapor sterilizer. The microbial challenge for the sterilizers were Bacillus stearothermophilus spores present on commercial spore strips or drawn into and applied onto sliding sheath anesthetic injection systems with anesthetic carpules attached. Spore-soiled items were placed into the middle of sharps containers three-quarters-filled with representative clinical waste and sterilized. If, after culturing, sterilization of all test items in a group was not achieved, additional sterilization time was applied. Spore strips were killed within a single cycle of each sterilizer. Spore-soiled injection systems and carpules could not be routinely sterilized in the gravity steam autoclave or unsaturated chemical vapor sterilizers, even after three consecutive sterilization cycles. These items, however, were sterilized by exposure to a single-treatment cycle in a high-vacuum steam autoclave. Results indicate that routine sterilization of spore contaminated anesthetic carpules or injection systems could not be accomplished in a reasonable amount of time using sterilizers commonly found in dental offices.

  10. Evaluation of new technique of sterilization using biological indicator.

    PubMed

    Sheth, Nomal Chintan; Rathod, Yogesh V; Shenoi, Pratima R; Shori, Deepa D; Khode, Rajiv T; Khadse, Amruta P

    2017-01-01

    A novel technique of sterilization of endodontic files is introduced in this article. Newly introduced sterilization unit, named "SteriFast" is compared with autoclave and glass bead sterilizer using biological indicator. Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental samples of endodontic files. These contaminated files were sterilized using three different techniques. The sterilized files were transferred into nutrient medium under aseptic condition. The results were observed after 24 h, 48 h, and 7 days. The results showed that autoclave and new sterilization device (SteriFast) showed complete sterilization. The files sterilized using glass bead sterilizer showed bacterial growth (80%). Thus, it proves that autoclave and SteriFast are ideal techniques of sterilization of endodontic files. Glass bead sterilizer does not completely sterilize the files. The article also compares SteriFast and autoclave in other aspects such as its design, basic principle, advantages, and disadvantages. The article also describes features and design of SteriFast, used for all kind of small dental instruments.

  11. Sterilization of medical equipment and contaminated articles by making use of a resistive barrier discharge

    NASA Astrophysics Data System (ADS)

    Uhm, Han S.; Kang, Jung G.; Choi, Eun H.; Cho, Guang S.

    2012-08-01

    Presented here is an apparatus consisting of an atmospheric resistive-barrier discharge for the sterilization of medical tools wrapped in typical hospital cloths, for the sterilization of manufactured drugs in typical packaging materials, and for the sterilization of biologically-contaminated articles. The sterilization apparatus consists of layers of the resistive-barrier discharge device operating at room temperature, a sterilization chamber, and an ozone destruction device. An electrical discharge in the resistive-barrier discharge system generates an atmospheric plasma in oxygen gas, generating ozone, which in turn efficiently sterilizes medical tools and biologically contaminated articles at room temperature. A sterilization experiment was carried out at an apparatus volume of 100 liters, with a sterilization chamber volume of 60 liters, and a discharge device volume of 40 liters. The sterilization in this experiment required 60 W of power for 5 hours of residence time. For a given sterilization time, the required electrical power was proportional to the apparatus volume. Ozone in the sterilization chamber was destroyed safely after sterilization.

  12. Hysteroscopic Sterilization

    MedlinePlus

    ... sterilization? Sterilization is a permanent form of birth control. What is tubal sterilization? Sterilization procedures for women are ... is quicker than from other types of sterilization. What are the risks of ... on for birth control. • There is a risk of injury to the ...

  13. Hospital steam sterilizer usage: could we switch off to save electricity and water?

    PubMed

    McGain, Forbes; Moore, Graham; Black, Jim

    2016-07-01

    Steam sterilization in hospitals is an energy and water intensive process. Our aim was to identify opportunities to improve electricity and water use. The objectives were to find: the time sterilizers spent active, idle and off; the variability in sterilizer use with the time of day and day of the week; and opportunities to switch off sterilizers instead of idling when no loads were waiting, and the resultant electricity and water savings. Analyses of routine data for one year of the activity of the four steam sterilizers in one hospital in Melbourne, Australia. We examined active sterilizer cycles, routine sterilizer switch-offs, and when sterilizers were active, idle and off. Several switch-off strategies were examined to identify electricity and water savings: switch off idle sterilizers when no loads are waiting and switch off one sterilizer after 10:00 h and a second sterilizer after midnight on all days. Sterilizers were active for 13,430 (38%) sterilizer-hours, off for 4822 (14%) sterilizer-hours, and idle for 16,788 (48%) sterilizer-hours. All four sterilizers were simultaneously active 9% of the time, and two or more sterilizers were idle for 69% of the time. A sterilizer was idle for two hours or less 13% of the time and idle for more than 2 h 87% of the time. A strategy to switch off idle sterilizers would reduce electricity use by 66 MWh and water use by 1004 kl per year, saving 26% electricity use and 13% of water use, resulting in financial savings of AUD$13,867 (UK£6,517) and a reduction in 79 tonnes of CO2 emissions per year. An alternative switch-off strategy of one sterilizer from 10:00 h onwards and a second from midnight would have saved 30 MWh and 456 kl of water. The methodology used of how hospital sterilizer use could be improved could be applied to all hospitals and more broadly to other equipment used in hospitals. © The Author(s) 2016.

  14. Interval Female Sterilization.

    PubMed

    Stuart, Gretchen S; Ramesh, Shanthi S

    2018-01-01

    Female sterilization is relied on by nearly one in three women aged 35-44 years in the United States. Sterilization procedures are among the most common procedures that obstetrician-gynecologists perform. The most frequent sterilization procedures include postpartum tubal ligation, laparoscopic tubal disruption or salpingectomy, and hysteroscopic tubal occlusion. The informed consent process for sterilization is crucial and requires shared decision-making between the patient and the health care provider. Counseling should include the specific risks and benefits of the specific surgical approaches. Additionally, women should be counseled on the alternatives to sterilization, including intrauterine contraceptives and subdermal contraceptive implants. Complications, including unplanned pregnancy after successful female sterilization, are rare. The objectives of this Clinical Expert Series are to describe the epidemiology of female sterilization, access to postpartum sterilization, advances in interval sterilization techniques, and clinical considerations in caring for women requesting sterilization.

  15. Spacecraft sterilization.

    NASA Technical Reports Server (NTRS)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  16. Evaluation of new technique of sterilization using biological indicator

    PubMed Central

    Sheth, Nomal Chintan; Rathod, Yogesh V.; Shenoi, Pratima R.; Shori, Deepa D.; Khode, Rajiv T.; Khadse, Amruta P.

    2017-01-01

    Background: A novel technique of sterilization of endodontic files is introduced in this article. Aims: Newly introduced sterilization unit, named “SteriFast” is compared with autoclave and glass bead sterilizer using biological indicator. Materials and Methods: Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental samples of endodontic files. These contaminated files were sterilized using three different techniques. The sterilized files were transferred into nutrient medium under aseptic condition. The results were observed after 24 h, 48 h, and 7 days. Results: The results showed that autoclave and new sterilization device (SteriFast) showed complete sterilization. The files sterilized using glass bead sterilizer showed bacterial growth (80%). Conclusions: Thus, it proves that autoclave and SteriFast are ideal techniques of sterilization of endodontic files. Glass bead sterilizer does not completely sterilize the files. The article also compares SteriFast and autoclave in other aspects such as its design, basic principle, advantages, and disadvantages. The article also describes features and design of SteriFast, used for all kind of small dental instruments. PMID:29386784

  17. Committee Opinion No. 695: Sterilization of Women: Ethical Issues and Considerations.

    PubMed

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  18. Committee Opinion No 695 Summary: Sterilization of Women: Ethical Issues and Considerations.

    PubMed

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  19. An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft

    NASA Technical Reports Server (NTRS)

    Farmer, F. H.; Fuller, H. V.; Hueschen, R. M.

    1973-01-01

    A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.

  20. Today's sterilizer is not your father's water heater.

    PubMed

    Moore, Thomas K

    2009-07-01

    Today's sterilizers are sophisticated, automatic, and computerized devices that accurately execute programmed jobs, creating uniform conditions inside pressure vessels to achieve sterilization. Specialized knowledge is necessary to ensure that the right cycle is selected; this requires an educated and competent operator.Perioperative nurses need to understand regulatory requirements for sterilizers, sterilizer design and performance validation, sterilizer cycle functions for everyday use, and everyday sterilization procedures.

  1. Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer

    NASA Astrophysics Data System (ADS)

    Li, Si; Zhang, Yangde; Liu, Weidong

    2006-09-01

    The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.

  2. A Shipping Container-Based Sterile Processing Unit for Low Resources Settings

    PubMed Central

    2016-01-01

    Deficiencies in the sterile processing of medical instruments contribute to poor outcomes for patients, such as surgical site infections, longer hospital stays, and deaths. In low resources settings, such as some rural and semi-rural areas and secondary and tertiary cities of developing countries, deficiencies in sterile processing are accentuated due to the lack of access to sterilization equipment, improperly maintained and malfunctioning equipment, lack of power to operate equipment, poor protocols, and inadequate quality control over inventory. Inspired by our sterile processing fieldwork at a district hospital in Sierra Leone in 2013, we built an autonomous, shipping-container-based sterile processing unit to address these deficiencies. The sterile processing unit, dubbed “the sterile box,” is a full suite capable of handling instruments from the moment they leave the operating room to the point they are sterile and ready to be reused for the next surgery. The sterile processing unit is self-sufficient in power and water and features an intake for contaminated instruments, decontamination, sterilization via non-electric steam sterilizers, and secure inventory storage. To validate efficacy, we ran tests of decontamination and sterilization performance. Results of 61 trials validate convincingly that our sterile processing unit achieves satisfactory outcomes for decontamination and sterilization and as such holds promise to support healthcare facilities in low resources settings. PMID:27007568

  3. Association of Hysteroscopic vs Laparoscopic Sterilization With Procedural, Gynecological, and Medical Outcomes.

    PubMed

    Bouillon, Kim; Bertrand, Marion; Bader, Georges; Lucot, Jean-Philippe; Dray-Spira, Rosemary; Zureik, Mahmoud

    2018-01-23

    Safety of hysteroscopic sterilization has been recently questioned following reports of general symptoms such as allergy, tiredness, and depression in addition to associated gynecological results such as pelvic pain, perforation of fallopian tubes or uterus, and unwanted pregnancy. To compare the risk of reported adverse events between hysteroscopic and laparoscopic sterilization. French nationwide cohort study using the national hospital discharge database linked to the health insurance claims database. Women aged 30 to 54 years receiving a first hysteroscopic or laparoscopic sterilization between 2010 and 2014 were included and were followed up through December 2015. Hysteroscopic sterilization vs laparoscopic sterilization. Risks of procedural complications (surgical and medical) and of gynecological (sterilization failure that includes salpingectomy, second sterilization procedure, or pregnancy; pregnancy; reoperation) and medical outcomes (all types of allergy; autoimmune diseases; thyroid disorder; use of analgesics, antimigraines, antidepressants, benzodiazepines; outpatient visits; sickness absence; suicide attempts; death) that occurred within 1 and 3 years after sterilization were compared using inverse probability of treatment-weighted Cox models. Of the 105 357 women included (95.5% of eligible participants; mean age, 41.3 years [SD, 3.7 years]), 71 303 (67.7% ) underwent hysteroscopic sterilization, and 34 054 (32.3%) underwent laparoscopic sterilization. During the hospitalization for sterilization, risk of surgical complications for hysteroscopic sterilization was lower: 0.13% for hysteroscopic sterilization vs 0.78% for laparoscopic sterilization (adjusted risk difference [RD], -0.64; 95% CI, -0.67 to -0.60) and was lower for medical complications: 0.06% vs 0.11% (adjusted RD, -0.05; 95% CI, -0.08 to -0.01). During the first year after sterilization, 4.83% of women who underwent hysteroscopic sterilization had a higher risk of sterilization failure than the 0.69% who underwent laparoscopic sterilization (adjusted hazard ratio [HR], 7.11; 95% CI, 5.92 to 8.54; adjusted RD, 4.23 per 100 person-years; 95% CI, 3.40 to 5.22). Additionally, 5.65% of women who underwent hysteroscopic sterilization required gynecological reoperation vs 1.76% of women who underwent laparoscopic sterilization (adjusted HR, 3.26; 95% CI, 2.90 to 3.67; adjusted RD, 4.63 per 100 person-years; 95% CI, 3.38 to 4.75); these differences persisted after 3 years, although attenuated. Hysteroscopic sterilization was associated with a lower risk of pregnancy within the first year of the procedure but was not significantly associated with a difference in risk of pregnancy by the third year (adjusted HR, 1.04; 95% CI, 0.83-1.30; adjusted RD, 0.01 per 100 person-years; 95% CI, -0.04 to 0.07). Risks of medical outcomes were not significantly increased with hysteroscopic sterilization compared with laparoscopic sterilization. Among women undergoing first sterilization, the use of hysteroscopic sterilization was significantly associated with higher risk of gynecological complications over 1 year and over 3 years than was laparoscopic sterilization. Risk of medical outcomes was not significantly increased over 1 year or over 3 years. These findings do not support increased medical risks associated with hysteroscopic sterilization.

  4. ISO radiation sterilization standards

    NASA Astrophysics Data System (ADS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-06-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, "Radiation Sterilization Material Qualification" 2. ISO TR 13409-1996, "Sterilization of health care products — Radiation sterilization — Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches" 3. ISO Draft TR, "Sterilization of health care products — Radiation sterilization Selection of a sterilization dose for a single production batch" li]4. ISO Draft TR, "Sterilization of health care products — Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits."

  5. Implementing AORN recommended practices for selection and use of packaging systems for sterilization.

    PubMed

    Morton, Paula J; Conner, Ramona

    2014-04-01

    The delivery of sterile products to the sterile field is essential to perioperative practice. The use of protective packaging for sterilized items is crucial to helping ensure that patients receive sterile items for surgical procedures. AORN's "Recommended practices for selection and use of packaging systems for sterilization" offers guidance to perioperative team members in evaluating, selecting, and using packaging systems that permit sterilization of the contents, prevent contamination of sterilized items until the package is opened for use, protect the items from damage during transport and storage, and permit aseptic delivery of the items to the sterile field. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Sterilization for Women and Men

    MedlinePlus

    f AQ FREQUENTLY ASKED QUESTIONS FAQ011 CONTRACEPTION Sterilization for Women and Men • What is sterilization? • How does tubal occlusion work to prevent pregnancy? • How effective is female sterilization? • Does female sterilization ...

  7. [Use of and verification with biological indicators in sterilizers belonging to dentistry surgeons from San Luis Potosi, Mexico].

    PubMed

    Patiño-Marín, N; Loyola-Rodríguez, J P; Tovar-Reyes, L F

    2001-01-01

    To assess the utilization of sterilizing equipment used by dentists, and verification of sterilization using biological indicators. A cross-sectional study was conducted in 1999-2000, among 130 (65%) dentists having sterilizing equipment, at Facultad de Estomatología, Universidad Autónoma de San Luis Potosí and Colegio Dental Potosino. Biological indicators for sterilization containing Bacillus subtilis and Bacillus stearothermophilus were used. Thirty autoclaves and 100 dry-heat sterilizers were evaluated: 23 (17.7%) of them showed bacterial growth. Twenty-one (16.1%) dentists already were using biological indicators to verify their sterilizing equipment. Both sterilization methods were found to allow bacterial growth with similar frequencies (p = > 0.66). Few dentists verify the quality of sterilization process through biological indicators; bacterial growth and failure of sterilization were evidenced.

  8. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

    PubMed

    Alfa, M J; DeGagne, P; Olson, N; Hizon, R

    1998-10-01

    The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

  9. Sterilization regret among married women in India: implications for the Indian national family planning program.

    PubMed

    Singh, Abhishek; Ogollah, Reuben; Ram, Faujdar; Pallikadavath, Saseendran

    2012-12-01

    In India, female sterilization accounts for 66% of contraceptive use, and age at sterilization is declining. It is likely that some women regret having been sterilized, but data on the prevalence of, and the social and economic correlates of, regret at the national level are insufficient. Data for analysis came from 30,999 sterilized women aged 15-49 interviewed in the 2005-2006 Indian National Family Health Survey. Logistic regression analyses and Wald tests were used to identify the social and demographic characteristics associated with sterilization regret. Nationally, 5% of sterilized women aged 15-49 reported sterilization regret. Women sterilized at age 30 or older were less likely than women sterilized before age 25 to express regret (odds ratio, 0.8). Compared with women having only sons, those who had only daughters were more likely to express regret (1.3), while those having both sons and daughters were less likely to express regret (0.8). Women who had experienced child loss had higher odds of reporting regret than women who had not (for one child lost, 1.6; for two or more children lost, 2.0). Given the large proportion of women undergoing sterilization, the potential numbers experiencing regret are considerable. If age at sterilization continues to decline, sterilization regret is likely to increase. Encouraging couples to delay sterilization and increasing the availability of highly effective reversible contraceptives are options that India may consider to avert sterilization regret.

  10. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    PubMed

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues.

  11. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  12. A novel steam explosion sterilization improving solid-state fermentation performance.

    PubMed

    Zhao, Zhi-Min; Wang, Lan; Chen, Hong-Zhang

    2015-09-01

    Traditional sterilization of solid medium (SM) requires lengthy time, degrades nutrients, and even sterilizes inadequately compared with that of liquid medium due to its low thermal conductivity. A novel sterilization strategy, high-temperature and short-time steam explosion (SE), was exploited for SM sterilization in this study. Results showed that SE conditions for complete sterilization were 172 °C for 2 min and 128 °C for 5 min. Glucose and xylose contents in medium after SE sterilization increased by 157% and 93% respectively compared with those after conventional sterilization (121 °C, 20 min) while fermentation inhibitors were not detected. FTIR spectra revealed that the mild SE conditions helped to release monosaccharides from the polysaccharides. Bacillus subtilis fermentation productivity on medium after SE sterilization was 3.83 times of that after conventional sterilization. Therefore, SE shortened sterilization time and improved SM nutrition, which facilitated fermentability of SM and should promote economy of solid-state fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Increasing Patient Safety by Closing the Sterile Production Gap-Part 3-Moist Heat Resistance of Bioburden.

    PubMed

    Agalloco, James P

    2017-01-01

    Terminal sterilization is considered the preferred means for the production of sterile drug products, as it affords enhanced safety for the patient because the formulation is sterilized in its sealed, final container. Despite the obvious patient benefits, the use of terminal sterilization is artificially constrained by unreasonable expectations for the minimum time-temperature process to be used. The core misunderstanding with terminal sterilization is the notion that destruction of a high population of a resistant biological indicator microorganism is required. More contemporary thinking on sterilization acknowledges that the bioburden is the actual target in sterilization and its destruction must be assured. In the application of low-temperature moist heat for terminal sterilization, especially subsequent to aseptic processing, establishing the pre-sterilization bioburden to consider has proven challenging. Environmental monitoring survey data has determined the identity of potential microorganisms but not their resistance to sterilization. This review article provides information on the moist heat resistance of vegetative and sporeforming microorganisms that might be present. The first paper in this series provided the overall background and described the benefits to patient, producer, and regulator of low-temperature moist heat for terminal sterilization. The second paper outlined validation and operational advice that can be used in the implementation. This final effort concludes the series and provides insight into potential bioburden and its resistance. LAY ABSTRACT: Terminal sterilization is considered the preferred means for the production of sterile drug products as it affords enhanced safety for the patient as the formulation is filled into its final container, sealed and sterilized. Despite the obvious patient benefits, the use of terminal sterilization is artificially constrained by unreasonable expectations for the minimum time-temperature process to be used. The primary consideration in terminal sterilization is the reliable destruction of the bioburden. The earlier manuscripts in this series described the principles and implementation of low temperature terminal sterilization processes where the sterilization conditions would destroy the expected bioburden present. To accomplish that reliably knowledge of the bioburden expected resistance to moist heat is necessary. This review article will identify publications where that data can be found. © PDA, Inc. 2017.

  14. Surgical sterilization among US men and women with employer-based insurance: A claims data analysis.

    PubMed

    Khan, Amir Ishaq; Patil, Dattatraya; Kawwass, Jennifer Fay; Zholudev, Vitaly; Mehta, Akanksha

    2018-05-18

    To assess variability in the use of surgical sterilization among privately insured U.S. men and women. We queried the MarketScan Commercial Claims database using CPT, ICD9, and HCPCS codes to identify 658,509 individuals between 18-65 years old (0.37% of total) who underwent male or female sterilization between 2009-2014. We examined annual trends using Cochran-Mantel-Haenszel test. We analyzed differences in age, geographic distribution, and family size using Wilcoxon sum-rank and generalized chi-squared tests. Between 2009-2014, 422,290 men (0.55% of total men) and 236,219 women (0.24% of total women) with employer-sponsored insurance underwent male and female sterilization, respectively. Annual male sterilizations decreased from 77,565 (0.60%) in 2009 to 61,436 (0.51%) in 2014 (p<.001), while annual female sterilizations decreased from 43,766 (0.26%) to 30,465 (0.19%) (p<.001) over the same time period. Median age at time of male or female sterilization was 38 and 37 years, respectively. The decision to undergo sterilization at age 35 or older was associated with family size of 4 or more individuals (p<.001). Sterilization was more common in urban areas, with 84% of male sterilizations and 79% of female sterilizations performed in urban areas. 79% of men compared to 60% of women who underwent sterilization were the primary policyholders of their employer-sponsored healthcare plans (p<.001). Male sterilization was twice as common as female sterilization in this privately insured cohort. Use of surgical sterilization was associated with increased age and larger family size. There was a decline in the annual number of male and female sterilizations during the study period. Male sterilization is more common among US men with employer-based insurance than among the general population. The decline in sterilization may reflect cultural factors and the rise of long-acting reversible contraception. Analyzing the sociodemographic factors impacting sterilization may provide insight into contraceptive choice and improve reproductive health services. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Failure of non-vacuum steam sterilization processes for dental handpieces.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are used in critical and semi-critical operative interventions. Although some dental professional bodies recommend that dental handpieces are sterilized between patient use there is a lack of clarity and understanding of the effectiveness of different steam sterilization processes. The internal mechanisms of dental handpieces contain narrow lumens (0.8-2.3 mm) which can impede the removal of air and ingress of saturated steam required to achieve sterilization conditions. To identify the extent of sterilization failure in dental handpieces using a non-vacuum process. In-vitro and in-vivo investigations were conducted on widely used UK bench-top steam sterilizers and three different types of dental handpieces. The sterilization process was monitored inside the lumens of dental handpieces using thermometric (TM; dataloggers), chemical indicator (CI), and biological indicator (BI) methods. All three methods of assessing achievement of sterility within dental handpieces that had been exposed to non-vacuum sterilization conditions demonstrated a significant number of failures [CI: 8/3024 (fails/no. of tests); BI: 15/3024; TM: 56/56] compared to vacuum sterilization conditions (CI: 2/1944; BI: 0/1944; TM: 0/36). The dental handpiece most likely to fail sterilization in the non-vacuum process was the surgical handpiece. Non-vacuum sterilizers located in general dental practice had a higher rate of sterilization failure (CI: 25/1620; BI: 32/1620; TM: 56/56) with no failures in vacuum process. Non-vacuum downward/gravity displacement, type N steam sterilizers are an unreliable method for sterilization of dental handpieces in general dental practice. The handpiece most likely to fail sterilization is the type most frequently used for surgical interventions. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Sterilization: A Review and Update.

    PubMed

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Nuclear-cytoplasmic male-sterility in diploid dandelions.

    PubMed

    van der Hulst, R G M; Meirmans, P; van Tienderen, P H; van Damme, J M M

    2004-07-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for male-fertility, partial male-sterility, and full male-sterility, and also segregated for small-sized versus normally sized pollen. The crossing results are best explained by a cytoplasmic male-sterility factor in combination with two dominant restorer genes. Involvement of the cytoplasmic male-sterility factor was further investigated by chloroplast haplotyping. Male-sterility was exclusively associated with a rare chloroplast haplotype (designated 16b). This haplotype was found in seven male-sterile plants and one (apparently restored) male-fertile individual but does not occur in 110 co-existing male-fertile plants and not in several hundreds of individuals previously haplotyped. Apomicts with cytoplasmic male sterility were generated in some test crosses. This raises the question as to whether the male sterility found in natural dandelion apomicts, is of cytoplasmic or of nuclear genetic nature. As many breeding systems in Taraxacum are involved in shaping population structure, it will be difficult to predict the evolutionary consequences of nuclear-cytoplasmic male-sterility for this species complex.

  18. Application of a Dense Gas Technique for Sterilizing Soft Biomaterials

    PubMed Central

    Karajanagi, Sandeep S.; Yoganathan, Roshan; Mammucari, Raffaella; Park, Hyoungshin; Cox, Julian; Zeitels, Steven M.; Langer, Robert; Foster, Neil R.

    2017-01-01

    Sterilization of soft biomaterials such as hydrogels is challenging because existing methods such as gamma irradiation, steam sterilization, or ethylene oxide sterilization, while effective at achieving high sterility assurance levels (SAL), may compromise their physicochemical properties and biocompatibility. New methods that effectively sterilize soft biomaterials without compromising their properties are therefore required. In this report, a dense-carbon dioxide (CO2)-based technique was used to sterilize soft polyethylene glycol (PEG)-based hydrogels while retaining their structure and physicochemical properties. Conventional sterilization methods such as gamma irradiation and steam sterilization severely compromised the structure of the hydrogels. PEG hydrogels with high water content and low elastic shear modulus (a measure of stiffness) were deliberately inoculated with bacteria and spores and then subjected to dense CO2. The dense CO2-based methods effectively sterilized the hydrogels achieving a SAL of 10−7 without compromising the viscoelastic properties, pH, water-content, and structure of the gels. Furthermore, dense CO2-treated gels were biocompatible and non-toxic when implanted subcutaneously in ferrets. The application of novel dense CO2-based methods to sterilize soft biomaterials has implications in developing safe sterilization methods for soft biomedical implants such as dermal fillers and viscosupplements. PMID:21337339

  19. Microbial barrier assessment of Tyvek stopper packaging for rubber closures.

    PubMed

    Moldenhauer, J E; Bass, S A; Kupinski, M J; Walters, M L; Rubio, S L

    1996-01-01

    Two types of Tyvek and high density polyethylene or polypropylene packaging used for sterilization of rubber closures were evaluated for Microbial Barrier properties. The packaging evaluated was "Ready to Sterilize" (1) stoppers and a second test package (Test 2) which was designated as appropriate for a clean room, filled with washed and siliconized stoppers and then heat sealed. Each type of packaging was subjected to three different sterilization temperatures (125 degrees C, 128 degrees C and 131 degrees C) in a production sterilizer (15-18 psi). Following sterilization, a microbial barrier assessment was performed, using Bacillus subtilis niger (ATCC 9372), to determine whether the packaging could maintain a sterile barrier following sterilization. Results of the testing indicated that a microbial barrier was maintained for products in "Ready to Sterilize" packages at 125 degrees C and 128 degrees C. For products sterilized in the Test 2 container a microbial barrier could not be maintained at 128 degrees C, and no further testing was performed. Following sterilization at 131 degrees C physical defects were noted for the "Ready to Sterilize" bag and a microbial barrier could not be maintained.

  20. Bag For Formulating And Dispersing Intravenous Solution

    NASA Technical Reports Server (NTRS)

    Kipp, Jim; Owens, Jim; Scharf, Mike; Finley, Mike; Dudar, Tom; Veillon, Joe; Ogle, Jim

    1993-01-01

    Large-volume parenteral (LVP) bag in which predetermined amount of sterile solution formulated by combining premeasured, prepackaged amount of sterile solute with predetermined amount of water. Bag designed to hold predetermined amount, typically 1 L, of sterile solution. Sterility of solution maintained during mixing by passing water into bag through sterilizing filter. System used in field or hospitals not having proper sterile facilities, and in field research.

  1. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    PubMed Central

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. PMID:28337488

  2. Does a History of Unintended Pregnancy Lessen the Likelihood of Desire for Sterilization Reversal?

    PubMed Central

    Grady, Cynthia D.; Schwarz, Eleanor Bimla; Emeremni, Chetachi A.; Yabes, Jonathan; Akers, Aletha; Zite, Nikki

    2013-01-01

    Abstract Background Unintended pregnancy has been significantly associated with subsequent female sterilization. Whether women who are sterilized after experiencing an unintended pregnancy are less likely to express desire for sterilization reversal is unknown. Methods This study used national, cross-sectional data collected by the 2006–2010 National Survey of Family Growth. The study sample included women ages 15–44 who were surgically sterile from a tubal sterilization at the time of interview. Multivariable logistic regression was used to examine the relationship between a history of unintended pregnancy and desire for sterilization reversal while controlling for potential confounders. Results In this nationally representative sample of 1,418 women who were sterile from a tubal sterilization, 78% had a history of at least one unintended pregnancy and 28% expressed a desire to have their sterilization reversed. In unadjusted analysis, having a prior unintended pregnancy was associated with higher odds of expressing desire for sterilization reversal (odds ratio [OR]: 1.80; 95% confidence interval [CI]: 1.15–2.79). In adjusted analysis controlling for sociodemographic factors, unintended pregnancy was no longer significantly associated with desire for reversal (OR: 1.46; 95% CI: 0.91–2.34). Conclusion Among women who had undergone tubal sterilization, a prior history of unintended pregnancy did not decrease desire for sterilization reversal. PMID:23621776

  3. Sterility maintenance study: Dynamic evaluation of sterilized rigid containers and wrapped instrument trays to prevent bacterial ingress.

    PubMed

    Shaffer, Harry L; Harnish, Delbert A; McDonald, Michael; Vernon, Reid A; Heimbuch, Brian K

    2015-12-01

    Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ~10(2) colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 μm, while simultaneously experiencing air volume exchanges due to vacuum cycles-two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles-to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria. Copyright © 2015. Published by Elsevier Inc.

  4. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  5. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  6. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  7. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  8. Sterile neutrino dark matter production

    NASA Astrophysics Data System (ADS)

    Gorbunov, Dmitry

    2017-10-01

    Sterile neutrinos provide active neutrinos with masses and mixing, and hence is one of the well-motivated candidate for dark matter. We discuss the sterile neutrino production mechanisms operating in the early Universe and show that additional scalar coupled to sterile neutrino can significantly change the situation, making moderate sterile-neutrino mixing and small sterile neutrino masses consistent with current cosmological and astrophysical bounds. Further searches for a narrow line in galactic X-rays and even direct searches for keV-scale sterile neutrinos in particle physics experiments can probe the suggested setup.

  9. Patient-provider conversations about sterilization: A qualitative analysis.

    PubMed

    Kimport, Katrina; Dehlendorf, Christine; Borrero, Sonya

    2017-03-01

    Although female sterilization is the second most commonly used contraceptive method in the US, research suggests that providers may serve as barriers to desired sterilization. We conducted a modified grounded theory analysis of audio-recorded contraceptive counseling visits with 52 women who specified on a previsit survey that they wanted no future children and a supplemental analysis of visits with 14 women who wanted or were unsure about future children in which sterilization was mentioned. Sterilization was discussed in only 19 of the 52 visits, primarily with patients who were older women with children. Although some framed sterilization positively, many clinicians discouraged patients from pursuing sterilization, encouraging them instead to use long-acting reversible methods and framing the permanence of sterilization as undesirable. In the 33 remaining sessions, sterilization was not mentioned, and clinicians largely failed to solicit patients' future reproductive intentions. We found no clear patterns regarding discussion of sterilization in the 14 supplemental cases. Clinicians did not discuss sterilization with all patients for whom it might have been appropriate and thus missed opportunities to discuss sterilization as part of the full range of appropriate methods. When they did discuss sterilization, they only infrequently presented the method in positive ways and more commonly encouraged patients to choose a long-acting reversible method instead. Clinicians may want to reflect on their counseling practices around sterilization to ensure that counseling is centered on patient preferences, rather than driven by their own assumptions about the desirability of reversibility. Clinicians often fail to discuss sterilization as a contraceptive option with potentially appropriate candidates and, when they do, often discourage its selection. Clinicians should consider assessing reproductive intentions to ensure that potentially relevant methods are included in counseling. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study.

    PubMed

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter; Sedrakyan, Art

    2015-10-13

    To compare the safety and efficacy of hysteroscopic sterilization with the "Essure" device with laparoscopic sterilization in a large, all-inclusive, state cohort. Population based cohort study. Outpatient interventional setting in New York State. Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. We identified 8048 patients undergoing hysteroscopic sterilization and 44,278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures should be discussed with patients for informed decisions making. © Mao et al 2015.

  11. Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organizations still advocate non-vacuum sterilization processes for these devices. To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Measurements at different positions within air turbines were undertaken with thermocouples and data loggers. Two examples of widely used UK benchtop steam sterilizers were tested: a non-vacuum benchtop sterilizer (Little Sister 3; Eschmann, Lancing, UK) and a vacuum benchtop sterilizer (Lisa; W&H, Bürmoos, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. A total of 140 measurements inside dental handpiece lumens were recorded. The non-vacuum process failed (time range: 0-150 s) to reliably achieve sterilization temperatures within the time limit specified by the international standard (15 s equilibration time). The measurement point at the base of the handpiece failed in all test runs (N = 9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces, and the base of the handpiece is the site most likely to fail. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    PubMed

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and inexpensive seed sterilization for a large number of Arabidopsis lines.

  13. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds

    PubMed Central

    Calhoun, Chistopher S.; Grotewold, Erich; Brkljacic, Jelena

    2017-01-01

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and inexpensive seed sterilization for a large number of Arabidopsis lines. PMID:29155739

  14. Effects of sterile neutrino and extra-dimension on big bang nucleosynthesis

    NASA Astrophysics Data System (ADS)

    Jang, Dukjae; Kusakabe, Motohiko; Cheoun, Myung-Ki

    2018-04-01

    We study effects of the sterile neutrino in the five-dimensional universe on the big bang nucleosynthesis (BBN). Since the five-dimensional universe model leads to an additional term in the Friedmann equation and the energy density of the sterile neutrino increases the total energy density, this model can affect the primordial abundance via changing the cosmic expansion rate. The energy density of the sterile neutrino can be determined by a rate equation for production of the sterile neutrino. We show that not only the mixing angle and the mass of the sterile neutrino, but also a resonant effect in the oscillation between sterile and active neutrinos is important to determine a relic abundance of the sterile neutrino. In this study, we also investigate how the sterile neutrino in extra-dimensional model can affect the BBN, and constrain the parameters related to the above properties of the sterile neutrino by using the observational primordial abundances of light elements.

  15. Effects of supercritical carbon dioxide sterilization on polysaccharidic membranes for surgical applications.

    PubMed

    Scognamiglio, F; Blanchy, M; Borgogna, M; Travan, A; Donati, I; Bosmans, J W A M; Foulc, M P; Bouvy, N D; Paoletti, S; Marsich, E

    2017-10-01

    Sterilization methods such as ɣ-irradiation, steam sterilization and ethylene oxide gas treatment can have negative effects on molecular structure and properties of polysaccharide-based biomaterials. In this perspective, the use of supercritical carbon dioxide (scCO 2 ) has been proposed as an alternative method for biomaterial sterilization. In this work, chemical, mechanical and biological properties of polysaccharidic membranes for surgical applications were investigated after sterilization by scCO 2 . Four sets of sterilizing conditions were considered and SEC analyses were performed in order to identify the one with lower impact on the polysaccharidic matrix of membranes (alginate). Mechanical tests showed that the resistance of membranes was slightly affected after sterilization. Biological analyses proved the biocompatibility of the sterilized membranes both in vitro and in a preliminary in vivo test. Overall, this study points out that this sterilization technique can be successfully employed to achieve an effective and safe sterilization of polysaccharidic membranes for surgical use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Misregulation of spermatogenesis genes in Drosophila hybrids is lineage-specific and driven by the combined effects of sterility and fast male regulatory divergence.

    PubMed

    Gomes, S; Civetta, A

    2014-09-01

    Hybrid male sterility is a common outcome of crosses between different species. Gene expression studies have found that a number of spermatogenesis genes are differentially expressed in sterile hybrid males, compared with parental species. Late-stage sperm development genes are particularly likely to be misexpressed, with fewer early-stage genes affected. Thus, a link has been posited between misexpression and sterility. A more recent alternative explanation for hybrid gene misexpression has been that it is independent of sterility and driven by divergent evolution of male-specific regulatory elements between species (faster male hypothesis). The faster male hypothesis predicts that misregulation of spermatogenesis genes should be independent of sterility and approximately the same in both hybrids, whereas sterility should only affect gene expression in sterile hybrids. To test the faster male hypothesis vs. the effect of sterility on gene misexpression, we analyse spermatogenesis gene expression in different species pairs of the Drosophila phylogeny, where hybrid male sterility occurs in only one direction of the interspecies cross (i.e. unidirectional sterility). We find significant differences among genes in misexpression with effects that are lineage-specific and caused by sterility or fast male regulatory divergence. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.

  17. Potential unintended pregnancies averted and cost savings associated with a revised Medicaid sterilization policy.

    PubMed

    Borrero, Sonya; Zite, Nikki; Potter, Joseph E; Trussell, James; Smith, Kenneth

    2013-12-01

    Medicaid sterilization policy, which includes a mandatory 30-day waiting period between consent and the sterilization procedure, poses significant logistical barriers for many women who desire publicly funded sterilization. Our goal was to estimate the number of unintended pregnancies and the associated costs resulting from unfulfilled sterilization requests due to Medicaid policy barriers. We constructed a cost-effectiveness model from the health care payer perspective to determine the incremental cost over a 1-year time horizon of the current Medicaid sterilization policy compared to a hypothetical, revised policy in which women who desire a postpartum sterilization would face significantly reduced barriers. Probability estimates for potential outcomes in the model were based on published sources; costs of Medicaid-funded sterilizations and Medicaid-covered births were based on data from the Medicaid Statistical Information System and The Guttmacher Institute, respectively. With the implementation of a revised Medicaid sterilization policy, we estimated that the number of fulfilled sterilization requests would increase by 45%, from 53.3% of all women having their sterilization requests fulfilled to 77.5%. Annually, this increase could potentially lead to over 29,000 unintended pregnancies averted and $215 million saved. A revised Medicaid sterilization policy could potentially honor women's reproductive decisions, reduce the number of unintended pregnancies and save a significant amount of public funds. Compared to the current federal Medicaid sterilization policy, a hypothetical, revised policy that reduces logistical barriers for women who desire publicly funded, postpartum sterilization could potentially avert over 29,000 unintended pregnancies annually and therefore lead to cost savings of $215 million each year. © 2013.

  18. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  19. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  20. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  1. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  2. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  3. 21 CFR 522.1862 - Sterile pralidoxime chloride.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...

  4. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  5. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  6. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  7. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  8. Sterilization techniques for biodegradable scaffolds in tissue engineering applications

    PubMed Central

    Dai, Zheng; Ronholm, Jennifer; Tian, Yiping; Sethi, Benu; Cao, Xudong

    2016-01-01

    Biodegradable scaffolds have been extensively studied due to their wide applications in biomaterials and tissue engineering. However, infections associated with in vivo use of these scaffolds by different microbiological contaminants remain to be a significant challenge. This review focuses on different sterilization techniques including heat, chemical, irradiation, and other novel sterilization techniques for various biodegradable scaffolds. Comparisons of these techniques, including their sterilization mechanisms, post-sterilization effects, and sterilization efficiencies, are discussed. PMID:27247758

  9. Cytological study of radiation induced alterations in cytoplasmic factors controlling male sterility in corn. Progress report, February 28, 1975--December 1, 1975

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwardson, J.R.

    1975-01-01

    Progress is reported on the following research projects: cytoplasmic constituents of the embryo of various gymnosperms and angiosperms; cytoplasmic male sterility in corn; modification of cytoplasmic sterility factors using gamma radiation, EMS, and ethidium bromide; selection for sterile, blight-resistant corn plants; electron microscopy study of abnormal mitochondria in cytoplasm of corn; cytoplasmic male sterility in Petunia; non-Mendelian variegation in Petunia and Nicotiana; graft transmission of cytoplasmic male sterility; cytoplasmic male sterility in Vicia faba; and studies on Blakeslee's I virus in Datura. (HLW)

  10. Disinfection and Sterilization in Health Care Facilities: An Overview and Current Issues.

    PubMed

    Rutala, William A; Weber, David J

    2016-09-01

    When properly used, disinfection and sterilization can ensure the safe use of invasive and noninvasive medical devices. The method of disinfection and sterilization depends on the intended use of the medical device: critical items (contact sterile tissue) must be sterilized before use; semicritical items (contact mucous membranes or nonintact skin) must be high-level disinfected; and noncritical items (contact intact skin) should receive low-level disinfection. Cleaning should always precede high-level disinfection and sterilization. Current disinfection and sterilization guidelines must be strictly followed. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Quarter of a century of female sterilization in Jos, Central Nigeria.

    PubMed

    Mutihir, Josiah T; Nyango, D D

    2011-03-01

    The study was to assess the types and trend of female sterilization between January 1985 and December 2009 (25 years) in Jos, Central Nigeria. There were 25,313 new acceptors of modern contraceptive methods out of which 4,951 (19.6%) were female sterilizations. Minilaparotomy was the commonest method of female sterilization. Local anaesthesia was the commonest anaesthetic utilized. The women were mostly women of relatively older age, grandmultiparous and with large family size. The women were of mean of 38.4 years, and 60% had more than 5 children at the time of sterilization. Interval sterilization constituted 78.5% of the female sterilizations. The acceptance of female sterilization, however, has declined over the years, as acceptance of the long acting contraceptive implants increases. Female sterilization by minilaparotomy under local anaesthesia was found to be feasible, cost effective and acceptable by majority of clients, and recommended for integration into minor gynaecological procedures in our institutions.

  12. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization.

  13. System for sterilizing objects. [cleaning space vehicle systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Wright, E. E., Jr.; Moyers, C. V. (Inventor)

    1981-01-01

    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

  14. [Genetic study on two maize male sterile mutants obtained by space mutagenesis].

    PubMed

    Li, Yu-Ling; Yu, Yong-Liang; Liu, Yan-Xia; Li, Xue-Hui; Fu, Jia-Feng

    2007-06-01

    Two maize male sterile mutants were selected from the offspring of four maize inbred lines, which were carried into space by the Shenzhou spaceship 4. Their genetic characteristic and stability was analyzed in present study. Crosses were made between the male sterile plants and fertile plants from the same line, and other inbred lines with normal cytoplasm. The ratios of the sterile plants with the fertile plants in their F1, F2 generations, and their reciprocal backcross generations with the male sterile plants were calculated. The results showed that the characteristic in male sterility was stable in different years, different seasons and different locations, and was inheritable from generation to generation. This male sterile was controlled by a single nuclear recessive gene. Since no pollens or a few malformed pollens existed in the anther of the sterile plants, it was a completely sterile type.

  15. Hybrid male sterility and genome-wide misexpression of male reproductive proteases.

    PubMed

    Gomes, Suzanne; Civetta, Alberto

    2015-07-06

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation.

  16. Hybrid male sterility and genome-wide misexpression of male reproductive proteases

    PubMed Central

    Gomes, Suzanne; Civetta, Alberto

    2015-01-01

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation. PMID:26146165

  17. Thermomechanical Properties, Antibiotic Release, and Bioactivity of a Sterilized Cyclodextrin Drug Delivery System

    PubMed Central

    Halpern, Jeffrey M.; Gormley, Catherine A.; Keech, Melissa; von Recum, Horst A.

    2014-01-01

    Various local drug delivery devices and coatings are being developed as slow, sustained release mechanism for drugs, yet the polymers are typically not evaluated after commercial sterilization techniques. We examine the effect that commercial sterilization techniques have on the physical, mechanical, and drug delivery properties of polyurethane polymers. Specifically we tested cyclodextrin-hexamethyl diisocyanate crosslinked polymers before and after autoclave, ethylene oxide, and gamma radiation sterilization processes. We found that there is no significant change in the properties of polymers sterilized by ethylene oxide and gamma radiation compared to non-sterilized polymers. Polymers sterilized by autoclave showed increased tensile strength (p<0.0001) compared to non-sterilized polymers . In the release of drugs, which were loaded after the autoclave sterilization process, we observed a prolonged release (p<0.05) and a prolonged therapeutic effect (p<0.05) but less drug loading (p<0.0001) compared to non-sterilized polymers. The change in the release profile and tensile strength in polymers sterilized by autoclave was interpreted as being caused by additional crosslinking from residual, unreacted, or partially-reacted crosslinker contained within the polymer. Autoclaving therefore represents additional thermo-processing to modify rate and dose from polyurethanes and other materials. PMID:24949201

  18. Trends of Various Techniques of Tubectomy: A Five Year Study in a Tertiary Institute

    PubMed Central

    Prasanna, Naveen; Channabasappa, Ramalingappa Antartani

    2016-01-01

    Introduction Female sterilization is one of the best and effective methods of contraception for women who have completed their family. Tubectomy during caesarean operation and minilaparotomy are popular methods in developing countries whereas laparoscopic sterilization and hysteroscopic tubal occlusion are the preferred methods in developed countries. Aim To know the trends, incidence and immediate complications of methods of female sterilizations performed at our institute. Materials and Methods This is a retrospective analytical study conducted at our tertiary care centre from January 2010 to December 2014 in Karnataka Institute of Medical Sciences, Hubli, Karnataka. The case files of all the patients who underwent sterilization were taken from the medical records section and reviewed in detail. The cases were grouped as caesarean tubectomy, minilaparotomy and laparoscopic sterilization, based on the abdominal entry. For minilaparotomy and during caesarean tubectomy, modified pomeroy’s technique was used. For laparoscopic sterilization, falope rings were used. Data was analysed by Karl Pearson’s correlation co-efficient method and Chi-Square test. The p-value < 0.05 was considered significant. Results Out of 5442 cases of female sterilization, 2872 underwent caesarean tubectomy, remaining half underwent minilaparotomy (1306) and laparoscopic sterilization (1264). Sterilizations were significantly more during puerperal period (caesarean tubectomy + post abortal + postpartum) compared to interval period. There was an increasing trend in caesarean tubectomy and laparoscopic sterilization. There were 11 procedure related complications in the laparoscopic sterilization, one in caesarean tubectomy and none in minilaparotomy. Two deaths were reported in minilaparotomy, one in laparoscopic sterilization and four in the caesarean tubectomy, which were due to septicaemia. Conclusion An increasing trend in caesarean tubectomy and laparoscopic sterilization is seen in this study. Female sterilization should be individualized based on the timing, place and surgeons experience. Sepsis is a major cause of death and asepsis could be compromised when female sterilization is done in large numbers in camps. Hence target related approach towards female sterilization should be avoided. Laparoscopic sterilization has more procedure related complications, which can be better handled in tertiary care centres. PMID:26894125

  19. Potential unintended pregnancies averted and cost savings associated with a revised Medicaid sterilization policy

    PubMed Central

    Borrero, Sonya; Zite, Nikki; Potter, Joseph E.; Trussell, James; Smith, Kenneth

    2013-01-01

    Objective Medicaid sterilization policy, which includes a mandatory 30-day waiting period between consent and the sterilization procedure, poses significant logistical barriers for many women who desire publicly-funded sterilization. Our goal was to estimate the number of unintended pregnancies and the associated costs resulting from unfulfilled sterilization requests due to Medicaid policy barriers. Study design We constructed a cost effectiveness model from the health care payer perspective to determine the incremental cost over a 1-year time horizon of the current Medicaid sterilization policy compared to a hypothetical, revised policy in which women who desire a post-partum sterilization would face significantly reduced barriers. Probability estimates for potential outcomes in the model were based on published sources; costs of Medicaid-funded sterilizations and Medicaid-covered births were based on data from the Medicaid Statistical Information System and The Guttmacher Institute, respectively. Results With the implementation of a revised Medicaid sterilization policy, we estimated that the number of fulfilled sterilization requests would increase by 45%, from 53.3% of all women having their sterilization requests fulfilled to 77.5%. Annually, this increase could potentially lead to over 29,000 unintended pregnancies averted and $215 million saved. Conclusion A revised Medicaid sterilization policy could potentially honor women's reproductive decisions, reduce the number of unintended pregnancies, and save a significant amount of public funds. Implication Compared to the current federal Medicaid sterilization policy, a hypothetical, revised policy that reduces logistical barriers for women who desire publicly-funded, post-partum sterilization could potentially avert over 29,000 unintended pregnancies annually and therefore lead to a cost savings of $215 million each year. PMID:24028751

  20. Genetic complexity underlying hybrid male sterility in Drosophila.

    PubMed

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-02-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility.

  1. Genetic complexity underlying hybrid male sterility in Drosophila.

    PubMed Central

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-01-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility. PMID:15020468

  2. 42 CFR 441.253 - Sterilization of a mentally competent individual aged 21 or older.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization of a mentally competent individual... LIMITS APPLICABLE TO SPECIFIC SERVICES Sterilizations § 441.253 Sterilization of a mentally competent individual aged 21 or older. FFP is available in expenditures for the sterilization of an individual only if...

  3. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  4. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  5. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  6. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  7. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  8. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam. (b...

  9. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    PubMed Central

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures should be discussed with patients for informed decisions making. PMID:26462857

  10. Confirmation of the sterilization effect using a high concentration of ozone gas for the bio-clean room.

    PubMed

    Iwamura, Takuji; Nagano, Katsunori; Nogami, Toshihiro; Matsuki, Noritomo; Kosaka, Noriyoshi; Shintani, Hideharu; Katoh, Miyoshi

    2013-01-01

    A high-level aseptic environment must be maintained in bio-cleanrooms used for the manufacture of sterile products. In the past, formaldehyde gas was most commonly used to sterilize bio-cleanrooms, but due to strict residual limitations there has been a need to develop a less toxic alternative choice. The authors have developed a revolutionary new sterilization system using a high concentration of ozone gas and used this system to sterilize an actual bio-cleanroom. This system integrates the ozone gas generator with the air conditioning system by proper control. The design specifications for the system included an ozone gas concentration of 200 ppm or more, relative humidity of 80% or more, and a sterilizing time of 120 min. Blow vents and suction ports were placed to ensure a uniform airflow which would extend through the entire room during ozone gas sterilization. Tests regarding long-term material exposure to ozone gas were conducted when the system was introduced to distinguish usable and unusable materials. In an actually constructed cleanroom, simulations were used to predict the evenness of the diffusion of ozone gas concentration and relative humidity during ozone gas sterilization, and measurements of the actual indoor ozone gas concentration, temperature and relative humidity during sterilization revealed that the ozone concentration and relative humidity needed for sterilization had been achieved generally throughout the entire environment. In addition, the CT value (mg/m(3) (=ppm) × min) , derived by multiplying the ozone gas concentration during ozone gas sterilization by the sterilization time, was equal to or greater than the target value of 24 × 10(3) (ppm·min) . When the results of sterilization in a cleanroom were confirmed using a biological indicator (BI) , negative results were obtained at all measurement points, demonstrating that sterilization was being performed effectively in the actual factory at which the ozone gas sterilization system had been introduced.

  11. A Bayesian Approach to Determination of F, D, and Z Values Used in Steam Sterilization Validation.

    PubMed

    Faya, Paul; Stamey, James D; Seaman, John W

    2017-01-01

    For manufacturers of sterile drug products, steam sterilization is a common method used to provide assurance of the sterility of manufacturing equipment and products. The validation of sterilization processes is a regulatory requirement and relies upon the estimation of key resistance parameters of microorganisms. Traditional methods have relied upon point estimates for the resistance parameters. In this paper, we propose a Bayesian method for estimation of the well-known D T , z , and F o values that are used in the development and validation of sterilization processes. A Bayesian approach allows the uncertainty about these values to be modeled using probability distributions, thereby providing a fully risk-based approach to measures of sterility assurance. An example is given using the survivor curve and fraction negative methods for estimation of resistance parameters, and we present a means by which a probabilistic conclusion can be made regarding the ability of a process to achieve a specified sterility criterion. LAY ABSTRACT: For manufacturers of sterile drug products, steam sterilization is a common method used to provide assurance of the sterility of manufacturing equipment and products. The validation of sterilization processes is a regulatory requirement and relies upon the estimation of key resistance parameters of microorganisms. Traditional methods have relied upon point estimates for the resistance parameters. In this paper, we propose a Bayesian method for estimation of the critical process parameters that are evaluated in the development and validation of sterilization processes. A Bayesian approach allows the uncertainty about these parameters to be modeled using probability distributions, thereby providing a fully risk-based approach to measures of sterility assurance. An example is given using the survivor curve and fraction negative methods for estimation of resistance parameters, and we present a means by which a probabilistic conclusion can be made regarding the ability of a process to achieve a specified sterility criterion. © PDA, Inc. 2017.

  12. Bringing men to the table: sterilization can be for him or for her.

    PubMed

    Shih, Grace; Zhang, Ying; Bukowski, Kyle; Chen, Angela

    2014-12-01

    Sterilization, male and female combined, is the most common use of contraception in the United States. Despite the lower risk, higher cost-efficacy, and high efficacy of vasectomy compared with female sterilization, more US women rely on female sterilization than male sterilization. Reasons for low use of vasectomy include lack of knowledge and misconceptions about the procedure, lack of access, provider bias, and patient preferences. This article will provide a basic overview of male and female sterilization, an exploration of vasectomy barriers, and ways obstetrician-gynecologists can increase vasectomy uptake including regular recommendation of vasectomy to patients in long-term committed relationships considering sterilization.

  13. Sterilization processes. Meeting the demands of today's health care technology.

    PubMed

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  14. Racial variation in tubal sterilization rates: The role of patient-level factors

    PubMed Central

    Borrero, Sonya; Abebe, Kaleab; Dehlendorf, Christine; Schwarz, Eleanor Bimla; Creinin, Mitchell D.; Nikolajski, Cara; Ibrahim, Said

    2010-01-01

    Objective To assess racial differences in attitudes and knowledge about sterilization. Design Cross-sectional survey Setting Questionnaires were mailed to participants’ home addresses Patients 193 women aged 18–45 who had undergone tubal sterilization. Intervention(s) None Main Outcome Measure Attitudes and knowledge about tubal sterilization and awareness of contraceptive alternatives Results We received 193 completed surveys (64% response rate). AA woman were more likely to have a family member who had undergone tubal sterilization, to report that their mothers influenced their sterilization decisions, and to report that prior unintended pregnancy and desire to avoid insertion of a foreign object were very important factors in their decision to choose sterilization over other methods. Compared to white women, AA women more often thought that sterilization reversal could easily restore fertility (62 % vs 36%); that a woman’s sterilization would reverse itself after 5 years (60% vs 23%); and that a man cannot ejaculate after vasectomy (38% vs 13%). Fewer AA women had ever heard of intrauterine contraception (90% vs 98%). Racial differences in knowledge remained statistically significant after adjusting for socioeconomic confounders. Conclusions Misinformation about sterilization and limited awareness of contraceptive alternatives among AA women may contribute to racial disparities in tubal sterilization rates. PMID:20579640

  15. Effect of disinfection and sterilization on the tensile strength, surface roughness, and wettability of elastomers.

    PubMed

    Kotha, Sunil Babu; Ramakrishnaiah, Ravikumar; Devang Divakar, Darshan; Celur, Sree Lalita; Qasim, Saad; Matinlinna, Jukka P

    2017-11-01

    The aim of the present study was to evaluate the effect of chemical disinfection, autoclave, and microwave sterilization on some of the key properties of elastomers. Five polyvinylsiloxane elastomeric impression materials were evaluated. Forty samples were fabricated from each material. The samples were randomly selected and assigned to four experimental groups with 50 samples each: group I, control; group II,chemical disinfection; group III, autoclave sterilization; and group IV, microwave sterilization. The differences in the mean values were contrasted and compared with the control group and analyzed using two-way analysis of variance (P < 0.05). The results showed that chemical disinfection and autoclave sterilization had no significant effect on the tensile strength and surface roughness, whereas microwave sterilization showed a statistically-significant reduction in tensile strength, and an increase in surface roughness. None of the disinfection and sterilization techniques had a significant effect on wettability. However, autoclave and microwave sterilization resulted in an increase in hydrophilicity of all the materials tested. Chemical disinfection and autoclave sterilization had no statistically-significant effect on the tested properties of elastomers, thus autoclave sterilization can be considered as an alternative and an effective mode of disinfection and sterilization to eliminate all forms of disease causing microorganisms from dental impressions. © 2016 John Wiley & Sons Australia, Ltd.

  16. Effect of repeated sterilization by different methods on strength of carbon fiber rods used in external fixator systems.

    PubMed

    Unal, Omer Kays; Poyanli, Oguz Sukru; Unal, Ulku Sur; Mutlu, Hasan Huseyin; Ozkut, Afsar Timucin; Esenkaya, Irfan

    2018-05-16

    We set out to reveal the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. We used a randomized set of forty-four unused, unsterilized, and identical carbon fiber rods (11 × 200 mm), randomly assigned to two groups: unsterilized (US) (4 rods) and sterilized (40 rods). The sterilized rods were divided into two groups, those sterilized in an autoclave (AC) and by hydrogen peroxide (HP). These were further divided into five subgroups based on the number of sterilization repetition to which the fibers were subjected (25-50-75-100-200). A bending test was conducted to measure the maximum bending force (MBF), maximum deflection (MD), flexural strength (FS), maximum bending moment (MBM) and bending rigidity (BR). We also measured the surface roughness of the rods. An increase in the number of sterilization repetition led to a decrease in MBF, MBM, FS, BR, but increased MD and surface roughness (p < 0.01). The effect of the number of sterilization repetition was more prominent in the HP group. This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.

  17. Plasma Sterilization: New Epoch in Medical Textiles

    NASA Astrophysics Data System (ADS)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  18. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America.

    PubMed

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35-13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights, improving counselling on HIV and sexual and reproductive health for WLHIV, providing State mechanisms to investigate and sanction coercive and forced sterilization, and strengthening civil society to increase WLHIV's capacity to resist coercion to sterilize can contribute to preventing coercive and forced sterilization. Improved access to judicial and non-judicial mechanisms to procure justice for women who have experienced reproductive rights violations is also needed.

  19. Sterilization as last resort in women with intellectual disabilities: protection or disservice?

    PubMed

    Insogna, Iris; Fiester, Autumn

    2015-01-01

    The legacy of the eugenics movement in the United States, including the involuntary sterilization of those deemed unfit to reproduce, has created a profound backlash against sterilization among certain populations. Particularly in treating women with intellectual disabilities, the field of obstetrics and gynecology has widely adopted an antisterilization stance. When treating women with intellectual disabilities, sterilization is generally considered a last resort. This essay revisits the issue of sterilization in women with intellectual disabilities, asking whether the field's stance of sterilization as a last resort is best viewed as a protection of this vulnerable population or one that actually does significant harm. We use a hypothetical but realistic patient case to examine the potential risks and benefits of sterilization. After reviewing the arguments against sterilization as a first-line treatment, we defend the controversial position that, in some cases, sterilization should be presented as an equally legitimate choice to reversible contraceptives. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. [Influence of autoclave sterilization on dimensional stability and detail reproduction of 5 additional silicone impression materials].

    PubMed

    Xu, Tong-kai; Sun, Zhi-hui; Jiang, Yong

    2012-03-01

    To evaluate the dimensional stability and detail reproduction of five additional silicone impression materials after autoclave sterilization. Impressions were made on the ISO 4823 standard mold containing several marking lines, in five kinds of additional silicone. All the impressions were sterilized by high temperature and pressure (135 °C, 212.8 kPa) for 25 min. Linear measurements of pre-sterilization and post-sterilization were made with a measuring microscope. Statistical analysis utilized single-factor analysis with pair-wise comparison of mean values when appropriate. Hypothesis testing was conducted at alpha = 0.05. No significant difference was found between the pre-sterilization and post-sterilization conditions for all locations, and all the absolute valuse of linear rate of change less than 8%. All the sterilization by the autoclave did not affect the surfuce detail reproduction of the 5 impression materials. The dimensional stability and detail reproduction of the five additional silicone impression materials in the study was unaffected by autoclave sterilization.

  1. Eugenics and Involuntary Sterilization: 1907-2015.

    PubMed

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  2. Implementing AORN recommended practices for sterile technique.

    PubMed

    Kennedy, Lynne

    2013-07-01

    Using sterile technique helps prevent the surgical environment from becoming contaminated and thus can help reduce the incidence of surgical site infection. The AORN "Recommended practices for sterile technique" provides guidance for setting up, maintaining, and monitoring a sterile field. Topics include the use of surgical attire and personal protective equipment; appropriate selection and evaluation of surgical gowns, gloves, and drape products for each procedure; use of sterile technique to don sterile gowns and gloves; appropriate methods for establishing and monitoring a sterile field; and techniques to ensure that items such as surgical instruments that may be contaminated are not used. Breaks in sterile technique should be corrected immediately unless the actions necessary would endanger the patient. If remedial actions must be delayed, they should be undertaken as soon as possible. Adhering to best practices for sterile technique requires remaining up to date with new approaches and incorporating these into quality initiatives. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  3. Implementing AORN recommended practices for sterilization.

    PubMed

    Graybill-D'Ercole, Patricia

    2013-05-01

    Any hospital or facility in which surgery and other invasive procedures are performed should have accommodations for cleaning, decontaminating, disinfecting, and sterilizing instruments, equipment, and other essential supplies that are used for patient procedures. Sterilization is essential to reducing or preventing the risk of surgical site infections. This is a collaborative process and should include all health care providers who handle these instruments, including perioperative nurses. The revised AORN "Recommended practices for sterilization," which became effective June 15, 2012, includes updates on sterilizing single-use items, inspecting critical items before sterilization, using low-temperature hydrogen peroxide vapor sterilization methods, and immediate use steam sterilization. This RP document is the first AORN document to be evidence rated and accepted for inclusion in the Agency for Healthcare Research and Quality National Guideline Clearinghouse. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  4. Increasing Patient Safety by Closing the Sterile Production Gap-Part 1. Introduction.

    PubMed

    Agalloco, James P

    2017-01-01

    Terminal sterilization is considered the preferred means for the production of sterile drug products because it affords enhanced safety for the patient as the formulation is filled into its final container, sealed, and sterilized. Despite the obvious patient benefits, the use of terminal sterilization is artificially constrained by unreasonable expectations for the minimum time-temperature process to be used. The core misunderstanding with terminal sterilization is a fixation that destruction of a high population of a resistant biological indicator is required. The origin of this misconception is unclear, but it has resulted in sterilization conditions that are extremely harsh (15 min at 121 °C, of F 0 > 8 min), which limit the use of terminal sterilization to extremely heat-stable formulations. These articles outline the artificial nature of the process constraints and describe a scientifically sound means to expand the use of terminal sterilization by identifying the correct process goal-destruction of the bioburden present in the container prior to sterilization. Recognition that the true intention is bioburden destruction in routine products allows for the use of reduced conditions (lower temperatures, shorter process dwell, or both) without added patient risk. By focusing attention on the correct process target, lower time-temperature conditions can be used to expand the use of terminal sterilization to products unable to withstand the harsh conditions that have been mistakenly applied. The first article provides the background and describes the benefits to patient, producer, and regulator. The second article includes validation and operational advice that can be used in the implementation. LAY ABSTRACT: Terminal sterilization is considered the preferred means for the production of sterile drug products because it affords enhanced safety for the patient as the formulation is filled into its final container, sealed, and sterilized. Despite the obvious patient benefits, the use of terminal sterilization is artificially constrained by unreasonable expectations for the minimum time-temperature process to be used. These articles outline the artificial nature of the process constraints and describe a scientifically sound means to expand the use of terminal sterilization by identifying the correct process goal-destruction of the bioburden present in the container prior to sterilization. By focusing attention on the correct process target, lower time-temperature conditions can be used to expand the use of terminal sterilization to products unable to withstand the harsh conditions that have been mistakenly applied. The first article provides the background, and describes the benefits to patient, producer, and regulator. The second article includes validation and operational advice that can be used in the implementation. © PDA, Inc. 2017.

  5. Contraception or eugenics? Sterilization and "mental retardation" in the 1970s and 1980s.

    PubMed

    Ladd-Taylor, Molly

    2014-01-01

    Nonconsensual sterilization is usually seen as the by-product of a classist and racist society; disability is ignored. This article examines the 1973 sterilization of two young black girls from Alabama and other precedent-setting court cases involving the sterilization of "mentally retarded" white women to make disability more central to the historical analysis of sterilization. It analyzes the concept of mental retardation and the appeal of a surgical solution to birth control, assesses judicial deliberations over the "right to choose" contraceptive sterilization when the capacity to consent is in doubt, and reflects on the shadow of eugenics that hung over the sterilization debate in the 1970s and 1980s.

  6. Ozone--the latest advance in sterilization of medical devices.

    PubMed

    Murphy, Lorna

    2006-06-01

    How many times have procedures in your operating rooms been delayed because the instruments needed were still in the sterilizer? As Perioperative nurses you are likely to be quite familiar with the constant pressure to ensure that scarce instrumentation is available when needed. In 2003, a Canadian company developed a unique sterilization process employing ozone as the sterilizing agent. This technology is a safe, rapid and economical alternative to other low temperature sterilization modalities and may relieve some of the pressure experienced when instruments in short supply are in high demand. This article will discuss the principles of the sterilizer and the cycle and will explore the advantages of using this sterilization technology.

  7. The sterility of hospital-prepared Soffban bandages.

    PubMed

    Wood, E V; Fenwick, H; Manning, M P; Mobbs, P

    2005-11-01

    An evaluation of the sterility of hospital-prepared Soffban bandages was undertaken. Discs of Bacillus stearothermophilus were inserted into the bandage rolls, prior to sterilization in "porous load" autoclaves. The discs were subsequently removed and placed in culture media, with growth of the organism indicating failure of sterilization. It was demonstrated that Soffban could not be sterilized reliably using standard hospital autoclave techniques.

  8. Influence of microwave sterilization on the cutting capacity of carbide burs.

    PubMed

    Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; Silva, Regina Helena Barbosa Tavares da; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo

    2009-01-01

    This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

  9. Investigation of a sterilization system using active oxygen species generated by ultraviolet irradiation.

    PubMed

    Yoshino, Kiyoshi; Matsumoto, Hiroyuki; Iwasaki, Tatsuyuki; Kinoshita, Shinobu; Noda, Kazutoshi; Oya, Kei; Iwamori, Satoru

    2015-01-01

    We have been investigating an advanced sterilization system that employs active oxygen species (AOS). We designed the sterilization equipment, including an evacuation system, which generates AOS from pure oxygen gas using ultraviolet irradiation, in order to study the conditions necessary for sterilization in the system's chamber. Using Geobachillus stearothermophilus spores (10(6) CFU) in a sterile bag as a biological indicator (BI) in the chamber of the AOS sterilization apparatus, we examined the viability of the BI as a function of exposure time, assessing the role of the decompression level in the sterilization performance. We found that the survival curves showed exponential reduction, and that the decompression level did not exert a significant influence on the survival curve. Subsequently, we investigated the sterilization effect as influenced by the spatial and environmental temperature variation throughout the chamber, and found that the sterilization effect varied with position, due to the varying environmental temperature in the respective areas. We confirmed that temperature is one of the most important factors influencing sterilization in the chamber, and estimated the temperature effect on the distribution of atomic oxygen concentration, using the quartz crystal microbalance (QCM) method with fluorocarbon thin film prepared by radio frequency sputtering.

  10. Probability of pregnancy after sterilization: a comparison of hysteroscopic versus laparoscopic sterilization.

    PubMed

    Gariepy, Aileen M; Creinin, Mitchell D; Smith, Kenneth J; Xu, Xiao

    2014-08-01

    To compare the expected probability of pregnancy after hysteroscopic versus laparoscopic sterilization based on available data using decision analysis. We developed an evidence-based Markov model to estimate the probability of pregnancy over 10 years after three different female sterilization procedures: hysteroscopic, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation. Parameter estimates for procedure success, probability of completing follow-up testing and risk of pregnancy after different sterilization procedures were obtained from published sources. In the base case analysis at all points in time after the sterilization procedure, the initial and cumulative risk of pregnancy after sterilization is higher in women opting for hysteroscopic than either laparoscopic band or bipolar sterilization. The expected pregnancy rates per 1000 women at 1 year are 57, 7 and 3 for hysteroscopic sterilization, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation, respectively. At 10 years, the cumulative pregnancy rates per 1000 women are 96, 24 and 30, respectively. Sensitivity analyses suggest that the three procedures would have an equivalent pregnancy risk of approximately 80 per 1000 women at 10 years if the probability of successful laparoscopic (band or bipolar) sterilization drops below 90% and successful coil placement on first hysteroscopic attempt increases to 98% or if the probability of undergoing a hysterosalpingogram increases to 100%. Based on available data, the expected population risk of pregnancy is higher after hysteroscopic than laparoscopic sterilization. Consistent with existing contraceptive classification, future characterization of hysteroscopic sterilization should distinguish "perfect" and "typical" use failure rates. Pregnancy probability at 1 year and over 10 years is expected to be higher in women having hysteroscopic as compared to laparoscopic sterilization. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Surface roughness of polyvinyl siloxane impression materials following chemical disinfection, autoclave and microwave sterilization.

    PubMed

    Al Kheraif, Abdulaziz Abdullah

    2013-05-01

    Autoclave sterilization and microwave sterilization has been suggested as the effective methods for the disinfection of elastomeric impressions, but subjecting elastomeric impressions to extreme temperature may have adverse effects on critical properties of the elastomers. To evaluate the effect of chemical disinfection as well as autoclave and microwave sterilization on the surface roughness of elastomeric impression materials. The surface roughness of five commercially available polyvinyl siloxane impression materials (Coltene President, Affinis Perfect impression, Aquasil, 3M ESPE Express and GC Exafast) were evaluated after subjecting them to chemical disinfection, autoclaving and microwave sterilization using a Talysurf Intra 50 instrument. Twenty specimens from each material were fabricated and divided into four equal groups, three experimental and one control (n=25). The differences in the mean surface roughness between the treatment groups were recorded and statistically analyzed. No statistically significant increase in the surface roughness was observed when the specimens were subjected to chemical disinfection and autoclave sterilization, increase in roughness and discoloration was observed in all the materials when specimens were subjected to microwave sterilization. Chemical disinfection did not have a significant effect but, since it is less effective, autoclave sterilization can be considered effective and autoclaving did not show any specimen discoloration as in microwave sterilization. Microwave sterilization may be considered when impressions are used to make diagnostic casts. A significant increase in surface roughness may produce rougher casts, resulting in rougher tissue surfaces for denture and cast restorations. Autoclave sterilization of vinyl polysiloxane elastomeric impressions for 5 minutes at 134°C at 20 psi may be considered an effective method over chemical disinfection and microwave sterilization, because chemical disinfection does not eliminate all disease-causing microorganisms and microwave sterilization leads to a rougher impression surface.

  12. Effects of Sterilization on the Physico-Chemical Properties of Natural Sediments From the Oak Ridge Reservation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, T.L.; Kukkadapu, R.K.; Madden, A.S.

    2009-04-29

    Batch U(VI) sorption/reduction experiments were completed on sterilized and non-sterilized sediment samples to elucidate biological and geochemical reduction mechanisms. Results from X-ray absorption near-edge structure (XANES) spectroscopy revealed that {gamma}-sterilized sediments were actually better sorbents of U(VI), despite the absence of any measurable biological activity. These results indicate that {gamma}-irradiation induced significant physico-chemical changes in the sediment which is contrary to numerous other studies identifying {gamma}-sterilization as an effective and minimally invasive technique. To identify the extent and method of alteration of the soil as a result of {gamma}-sterilization, untreated soil samples, physically separated size fractions, and chemically extracted fractionsmore » of the soil were analyzed pre- and post-sterilization. The effects of sterilization on mineralogy, pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state were determined. Results indicated that major mineralogy of the clay and whole sediment samples was unchanged. Sediment pH decreased only slightly with {gamma}-irradiation; however, irradiation produced a significant decrease in CEC of the untreated sediments and affected both the organic and inorganic fractions. Moessbauer spectra of non-sterile and {gamma}-sterilized sediments measured more reduced iron present in {gamma}-sterilized sediments compared to non-sterile samples. Our results suggest that sterilization by {gamma}-irradiation induced iron reduction that may have increased the sorption and/or reduction of U(VI) onto these sediments. However, Moessbauer and batch sorption data are somewhat contradictory, the former indicates that the iron oxide or iron hydroxide minerals are more significantly reduced while the later indicates that reduced clay minerals account for greater sorption of U(VI).« less

  13. Effects of gamma-sterilization on the physicochemical properties of natural sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, Tracy L; Madden, Andrew; Baldwin, Mark E

    2008-06-01

    Batch U(VI) sorption/reduction experiments were completed on sterilized and non-sterilized sediment samples to elucidate biological and geochemical reduction mechanisms. Results from X-ray absorption near-edge structure (XANES) spectroscopy revealed that {gamma}-sterilized sediments were actually better sorbents of U(VI), despite the absence of any measurable biological activity. These results indicate that {gamma}-irradiation induced significant physico-chemical changes in the sediment which is contrary to numerous other studies identifying {gamma}-sterilization as an effective and minimally invasive technique. To identify the extent and method of alteration of the soil as a result of {gamma}-sterilization, untreated soil samples, physically separated size fractions, and chemically extracted fractionsmore » of the soil were analyzed pre- and post-sterilization. The effects of sterilization on mineralogy, pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state were determined. Results indicated that major mineralogy of the clay and whole sediment samples was unchanged. Sediment pH decreased only slightly with {gamma}-irradiation; however, irradiation produced a significant decrease in CEC of the untreated sediments and affected both the organic and inorganic fractions. Moessbauer spectra of non-sterile and {gamma}-sterilized sediments measured more reduced iron present in {gamma}-sterilized sediments compared to non-sterile samples. Our results suggest that sterilization by {gamma}-irradiation induced iron reduction that may have increased the sorption and/or reduction of U(VI) onto these sediments. However, Moessbauer and batch sorption data are somewhat contradictory, the former indicates that the iron oxide or iron hydroxide minerals are more significantly reduced while the later indicates that reduced clay minerals account for greater sorption of U(VI).« less

  14. Electrolytic silver ion cell sterilizes water supply

    NASA Technical Reports Server (NTRS)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  15. The use of spore strips for monitoring the sterilization of bottled fluids.

    PubMed Central

    Selkon, J. B.; Sisson, P. R.; Ingham, H. R.

    1979-01-01

    A bacterial spore test has been developed which enables the efficacy of the sterilizing cycle recommended by the British Pharmaceutical Codex (1973) for bottled fluids to be accurately monitored. During a 14-month period this test detected faults in 3.3% of the sterilizing cycles, representing five distinct episodes of sterilization failure that passed unnoticed by the conventional controls of physical measurements and sterility testing. There were no failures of sterilization as detected by conventional techniques which were not indicated by the spore test. PMID:458140

  16. Improved Sterilization of Sensitive Biomaterials with Supercritical Carbon Dioxide at Low Temperature

    PubMed Central

    Bernhardt, Anne; Wehrl, Markus; Paul, Birgit; Hochmuth, Thomas; Schumacher, Matthias; Schütz, Kathleen; Gelinsky, Michael

    2015-01-01

    The development of bio-resorbable implant materials is rapidly going on. Sterilization of those materials is inevitable to assure the hygienic requirements for critical medical devices according to the medical device directive (MDD, 93/42/EG). Biopolymer-containing biomaterials are often highly sensitive towards classical sterilization procedures like steam, ethylene oxide treatment or gamma irradiation. Supercritical CO2 (scCO2) treatment is a promising strategy for the terminal sterilization of sensitive biomaterials at low temperature. In combination with low amounts of additives scCO2 treatment effectively inactivates microorganisms including bacterial spores. We established a scCO2 sterilization procedure under addition of 0.25% water, 0.15% hydrogen peroxide and 0.5% acetic anhydride. The procedure was successfully tested for the inactivation of a wide panel of microorganisms including endospores of different bacterial species, vegetative cells of gram positive and negative bacteria including mycobacteria, fungi including yeast, and bacteriophages. For robust testing of the sterilization effect with regard to later application of implant materials sterilization all microorganisms were embedded in alginate/agarose cylinders that were used as Process Challenge Devices (PCD). These PCD served as surrogate models for bioresorbable 3D scaffolds. Furthermore, the impact of scCO2 sterilization on mechanical properties of polysaccharide-based hydrogels and collagen-based scaffolds was analyzed. The procedure was shown to be less compromising on mechanical and rheological properties compared to established low-temperature sterilization methods like gamma irradiation and ethylene oxide exposure as well as conventional steam sterilization. Cytocompatibility of alginate gels and scaffolds from mineralized collagen was compared after sterilization with ethylene oxide, gamma irradiation, steam sterilization and scCO2 treatment. Human mesenchymal stem cell viability and proliferation were not compromised by scCO2 treatment of these materials and scaffolds. We conclude that scCO2 sterilization under addition of water, hydrogen peroxide and acetic anhydride is a very effective, gentle, non-cytotoxic and thus a promising alternative sterilization method especially for biomaterials. PMID:26067982

  17. [Assessment of decontamination processes: cleaning, disinfection and sterilization in dental practice in Poland in the years 2011-2012].

    PubMed

    Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Chojecka, Agnieszka; Zmuda-Baranowska, Magdalena; Kanclerski, Krzysztof

    2012-01-01

    Effective decontamination of instruments is a key element of infection control and the provision of high quality in dental care. The aim of the study was to evaluate the efficiency of decontamination procedures including cleaning, disinfection and sterilization of re-usable instruments in dental practices in Poland. The efficiency of disinfection and sterilization processes have been evaluated on the results of the questionnaires. The following information were taken into account: setting where disinfection and sterilization had been performed, preparation of dental equipment for sterilization (disinfection, washing and cleaning, packaging), the types of autoclaves and used types of sterilization cycles, routine monitoring and documentation of sterilization processes, treatment of handpieces and the frequency of surface decontamination. Data were collected from 43 dental practices (35 dental offices and 8 clinics). Disinfection and cleaning processes were performed manually in 63% of dental offices and ultrasonic baths were used in 53% of settings. Washer disinfectors were used in 23% of dental practices: in every researched clinic and in a few dental offices. All sterilization processes were performed in steam autoclaves, mainly in small steam sterilizers (81%). Dental handpieces were sterilized in 72% of practices, but only 33% of them performed sterilization in recommended cycle B. Sterilization processes were monitored with chemical indicators in 33% of practices. Biological monitoring of the processes was carried out at different intervals. Incorrect documentation of instruments and surfaces decontamination was recorded in several settings. There is still a need for improvement of decontamination processes in dental practice in Poland. Areas for improvement include: replacement of manual cleaning and disinfection processes with automatic processes, sterilization of dental handpieces after each patient, monitoring of a sterilization process with chemical and biological indicators. Reported incorrect procedures in decontamination of medical devices performed by questioned dentists and lack or inadequate response to asked questions indicate the lack of adequate knowledge about decontamination. Personnel who performs decontamination processes should be continuously trained.

  18. The perplexing links between contraceptive sterilization and (dis)advantage in ten low-fertility countries1

    PubMed Central

    Eeckhaut, Mieke C. W.; Sweeney, Megan M.

    2015-01-01

    This study investigates the association between sterilization and socioeconomic status in comparative context, using data from the 2006–10 National Survey of Family Growth and the 2004–10 Generations and Gender Surveys. We first confirm that longstanding patterns of association between socioeconomic status and sterilization persist in the contemporary United States. Specifically, female sterilization is associated with economic disadvantage whereas male sterilization is associated with economic advantage. We next show that female sterilization is similarly associated with disadvantage in most study countries, whereas a positive association between socioeconomic advantage and male sterilization is largely unique to the United States. However, while basic demographic background factors such as early childbearing and parity can explain the observed associations in most study countries, a strong gendered association between sterilization and socioeconomic status remains in the U.S. and Belgium even when adjusting for these factors. PMID:26792541

  19. Sterile neutrinos in cosmology

    NASA Astrophysics Data System (ADS)

    Abazajian, Kevork N.

    2017-11-01

    Sterile neutrinos are natural extensions to the standard model of particle physics in neutrino mass generation mechanisms. If they are relatively light, less than approximately 10 keV, they can alter cosmology significantly, from the early Universe to the matter and radiation energy density today. Here, we review the cosmological role such light sterile neutrinos can play from the early Universe, including production of keV-scale sterile neutrinos as dark matter candidates, and dynamics of light eV-scale sterile neutrinos during the weakly-coupled active neutrino era. We review proposed signatures of light sterile neutrinos in cosmic microwave background and large scale structure data. We also discuss keV-scale sterile neutrino dark matter decay signatures in X-ray observations, including recent candidate ∼3.5 keV X-ray line detections consistent with the decay of a ∼7 keV sterile neutrino dark matter particle.

  20. Signature of heavy sterile neutrinos at CEPC

    NASA Astrophysics Data System (ADS)

    Liao, Wei; Wu, Xiao-Hong

    2018-03-01

    We study the production of heavy sterile neutrino N , e+e-→N ν (ν ¯), at the Circular Electron Positron Collider (CEPC) and its l j j signal in its decay to three charged fermions. We study background events for this process which are mainly events coming from W pair production. We study the production of a single heavy sterile neutrino and the sensitivity of CEPC to the mixing of the sterile neutrino with active neutrinos. We study the production of two degenerate heavy sterile neutrinos in a low energy seesaw model by taking into account the constraints on mixings of sterile neutrinos from the neutrinoless double β decay experiment and the masses and mixings of active neutrinos. We show that CEPC under proposal has a good sensitivity to the mixing of sterile neutrinos with active neutrinos for a mass of a sterile neutrino around 100 GeV.

  1. [Contraceptive choices and experience of sexuality: a comparison between sterilized and non-sterilized women in a metropolitan area of southeastern Brazil].

    PubMed

    Villela, W; Barbosa, R

    1996-10-01

    A cross sectional study involving 357 women, 174 of them sterilized and 183 non-sterilized, with a view to comparing their sexual and reproductive behaviour, was undertaken. The questionnaire was based on previous focus group discussions with both women and men, to find out the best way to approach related questions. The results show that sterilized women-who are older and more often have steady partnerships than non-sterilized women-fulfil traditional gender roles more closely than the others. Furthermore, no sterilized woman had used the condom in the month prior to the interview. It is suggested that public messages for the prevention of the spread of the HIV, sexually-transmissible disease and cervical cancer should target women who have been sterilized for the purpose of increasing the use of the condom in accordance with specific strategies.

  2. Product sterilization. Why industry uses radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, B.J.

    1984-09-01

    Industry uses gamma radiation sterilization because of its superior reliability, safety, and cost savings over the EO fumigation method. EO has many processing variables and is toxic and expensive. The Environmental Protection Agency has recently declared EO to be both mutagenic and carcinogenic. The residual EO in hospital products has been reported to adversely affect hospital workers. Unlike EO fumigation, radiation sterilization imparts no toxic residuals. The coloration and embrittlement problems experienced earlier with some products sterilized by gamma radiation are being overcome with the introduction of new manufacturing materials and lower radiation dosages. Other benefits of radiation sterilization includemore » the option of sterilizing some materials that could not otherwise be sterilized and using new types of packaging to better protect the products and increase shelf-life. The emphasis now being placed on cost containment for health care products will be another significant part of the answer to why industry uses gamma radiation sterilization.« less

  3. Pre-Release Consumption of Methyl Eugenol Increases the Mating Competitiveness of Sterile Males of the Oriental Fruit Fly, Bactrocera dorsalis, in Large Field Enclosures

    PubMed Central

    Shelly, Todd E.; Edu, James; McInnis, Donald

    2010-01-01

    The sterile insect technique may be implemented to control populations of the oriental fruit fly, Bactrocera dorsalis (Hendel) (Diptera: Tephritidae), when environmental concerns preclude widespread use of chemical attractants or toxicants. The goal of the present study was to evaluate whether the mating competitiveness of sterile B. dorsalis males could be increased via pre-release feeding on methyl eugenol. Males of the oriental fruit fly are strongly attracted to this plant-borne compound, which they ingest and use in the synthesis of the sex pheromone. Previous studies conducted in the laboratory and small field-cages have shown that males given methyl eugenol produce a more attractive pheromone for females and have a higher mating success rate than males denied methyl eugenol. Here, levels of egg sterility were compared following the release of wild-like flies and either methyl eugenol-fed (treated) or methyl eugenol-deprived (control) sterile males in large field enclosures at four over flooding ratios ranging from 5:1 to 60:1 (sterile: wild-like males). Treated sterile males were fed methyl eugenol for 1–4 h (depending on the over flooding ratio tested) 3 d prior to release. Eggs were dissected from introduced fruits (apples), incubated in the laboratory, and scored for hatch rate. The effect of methyl eugenol was most pronounced at lower over flooding ratios. At the 5:1 and 10:1 over flooding ratios, the level of egg sterility observed for treated, sterile males was significantly greater than that observed for control, sterile males. In addition, the incidence of egg sterility reported for treated sterile males at these lower over flooding ratios was similar to that noted for treated or control sterile males at the 30:1 or 60:1 over flooding ratios. This latter result, in particular, suggests that pre-release feeding on methyl eugenol allows for a reduction in the number of sterile flies that are produced and released, thus increasing the cost-effectiveness of the sterile insect technique. PMID:20569140

  4. Comparison of hydrogen peroxide and peracetic acid as isolator sterilization agents in a hospital pharmacy.

    PubMed

    Bounoure, Frederic; Fiquet, Herve; Arnaud, Philippe

    2006-03-01

    The efficacy of hydrogen peroxide and peracetic acid as isolator sterilization agents was compared. Sterilization and efficacy tests were conducted in a flexible 0.8-m3 transfer isolator using a standard load of glass bottles and sterile medical devices in their packing paper. Bacillus stearothermophilus spores were placed in six critical locations of the isolator and incubated at 55 degrees C in a culture medium for 14 days. Sterilization by 4.25 mL/m3 of 33% vapor-phase hydrogen peroxide and 12.5 mL/m3 of 3.5% peracetic acid was tested in triplicate. Sterility was validated for hydrogen peroxide and peracetic acid at 60, 90, 120, and 180 minutes and at 90, 120, 150, 180, 210, and 240 minutes, respectively. In an efficacy test conducted with an empty isolator, the sterilization time required to destroy B. stearothermophilus spores was 90 minutes for both sterilants, indicating that they have comparable bactericidal properties. During the validation test with a standard load, the sterilization time using hydrogen peroxide was 150 minutes versus 120 minutes with peracetic acid. The glove cuff was particularly difficult for hydrogen peroxide to sterilize, likely due to its slower diffusion time than that of peracetic acid. Hydrogen peroxide is an environmentally safer agent than peracetic acid; however, its bacteriostatic properties, lack of odor, and poor diffusion time may limit its use in sterilizing some materials. Hydrogen peroxide is a useful alternative to peracetic acid for isolator sterilization in a hospital pharmacy or parenteral nutrition preparation unit.

  5. Evolution of postmating reproductive isolation: measuring the fitness effects of chromosomal regions containing hybrid male sterility factors.

    PubMed

    Johnson, N A; Wu, C I

    1993-08-01

    At least six regions of the X chromosome can cause male sterility when introgressed from Drosophila mauritiana into Drosophila simulans. In this article, we present the results of the other fitness effects caused by two X-linked regions that contain hybrid male sterility factors. In both regions, females that are heterozygous for an introgression with such a sterility factor produce substantially-fewer offspring than females heterozygous for an introgression that lacks the sterility factor. Thus, the hybrid male sterility factors, or other genes nearby, have substantial effects on female productivity. In contrast, hybrid male sterility factors have little or no effect on the relative viabilities of either sex. The evolutionary implications of these findings are discussed.

  6. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America

    PubMed Central

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Introduction Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Methods Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. Results A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35–13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. Conclusions The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights, improving counselling on HIV and sexual and reproductive health for WLHIV, providing State mechanisms to investigate and sanction coercive and forced sterilization, and strengthening civil society to increase WLHIV's capacity to resist coercion to sterilize can contribute to preventing coercive and forced sterilization. Improved access to judicial and non-judicial mechanisms to procure justice for women who have experienced reproductive rights violations is also needed. PMID:25808633

  7. Sterilization of Exopolysaccharides Produced by Deep-Sea Bacteria: Impact on Their Stability and Degradation

    PubMed Central

    Rederstorff, Emilie; Fatimi, Ahmed; Sinquin, Corinne; Ratiskol, Jacqueline; Merceron, Christophe; Vinatier, Claire; Weiss, Pierre; Colliec-Jouault, Sylvia

    2011-01-01

    Polysaccharides are highly heat-sensitive macromolecules, so high temperature treatments are greatly destructive and cause considerable damage, such as a great decrease in both viscosity and molecular weight of the polymer. The technical feasibility of the production of exopolysaccharides by deep-sea bacteria Vibrio diabolicus and Alteromonas infernus was previously demonstrated using a bioproduct manufacturing process. The objective of this study was to determine which sterilization method, other than heat sterilization, was the most appropriate for these marine exopolysaccharides and was in accordance with bioprocess engineering requirements. Chemical sterilization using low-temperature ethylene oxide and a mixture of ionized gases (plasmas) was compared to the sterilization methods using gamma and beta radiations. The changes to both the physical and chemical properties of the sterilized exopolysaccharides were analyzed. The use of ethylene oxide can be recommended for the sterilization of polysaccharides as a weak effect on both rheological and structural properties was observed. This low-temperature gas sterilizing process is very efficient, giving a good Sterility Assurance Level (SAL), and is also well suited to large-scale compound manufacturing in the pharmaceutical industry. PMID:21566796

  8. Measuring the sterile neutrino CP phase at DUNE and T2HK

    NASA Astrophysics Data System (ADS)

    Choubey, Sandhya; Dutta, Debajyoti; Pramanik, Dipyaman

    2018-04-01

    The CP phases associated with the sterile neutrino cannot be measured in the dedicated short-baseline experiments being built to test the sterile neutrino hypothesis. On the other hand, these phases can be measured in long-baseline experiments, even though the main goal of these experiments is not to test or measure sterile neutrino parameters. In particular, the sterile neutrino phase δ _{24} affects the charged-current electron appearance data in long-baseline experiment. In this paper we show how well the sterile neutrino phase δ _{24} can be measured by the next-generation long-baseline experiments DUNE, T2HK (and T2HKK). We also show the expected precision with which this sterile phase can be measured by combining the DUNE data with data from T2HK or T2HKK. The T2HK experiment is seen to be able to measure the sterile phase δ _{24} to a reasonable precision. We also present the sensitivity of these experiments to the sterile mixing angles, both by themselves, as well as when DUNE is combined with T2HK or T2HKK.

  9. Plasma Sterilization Technology for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Fraser, S. J.; Olson, R. L.; Leavens, W. M.

    1975-01-01

    The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

  10. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    PubMed

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  11. INFLUENCE OF MICROWAVE STERILIZATION ON THE CUTTING CAPACITY OF CARBIDE BURS

    PubMed Central

    Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; da Silva, Regina Helena Barbosa Tavares; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo

    2009-01-01

    Objective: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Material and Methods: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control – no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. Results: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Conclusion: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods. PMID:20027431

  12. Increasing Patient Safety by Closing the Sterile Production Gap-Part 2. Implementation.

    PubMed

    Agalloco, James P

    2017-01-01

    Terminal sterilization is considered the preferred means for the production of sterile drug products because it affords enhanced safety for the patient as the formulation is filled into its final container, sealed, and sterilized. Despite the obvious patient benefits, the use of terminal sterilization is artificially constrained by unreasonable expectations for the minimum time-temperature process to be used. The core misunderstanding with terminal sterilization is a fixation that destruction of a high concentration of a resistant biological indicator is required. The origin of this misconception is unclear, but it has resulted in sterilization conditions that are extremely harsh (15 min at 121 °C, of F 0 >8 min), which limit the use of terminal sterilization to extremely heat-stable formulations. These articles outline the artificial nature of the process constraints and describe a scientifically sound means to expand the use of terminal sterilization by identifying the correct process goal-the destruction of the bioburden present in the container prior to sterilization. Recognition that the true intention is bioburden destruction in routine products allows for the use of reduced conditions (lower temperatures, shorter process dwell, or both) without added patient risk. By focusing attention on the correct process target, lower time-temperature conditions can be used to expand the use of terminal sterilization to products unable to withstand the harsh conditions that have been mistakenly applied. The first article provides the background, and describes the benefits to patient, producer, and regulator. The second article includes validation and operational advice that can be used in the implementation. LAY ABSTRACT: Terminal sterilization is considered the preferred means for the production of sterile drug products because it affords enhanced safety for the patient as the formulation is filled into its final container, sealed, and sterilized. Despite the obvious patient benefits, the use of terminal sterilization is artificially constrained by unreasonable expectations for the minimum time-temperature process to be used. These articles outline the artificial nature of the process constraints and describe a scientifically sound means to expand the use of terminal sterilization by identifying the correct process goal-the destruction of the bioburden present in the container prior to sterilization. By focusing attention on the correct process target, lower time-temperature conditions can be used to expand the use of terminal sterilization to products unable to withstand the harsh conditions that have been mistakenly applied. The first article provides the background, and describes the benefits to patient, producer, and regulator. The article manuscript includes validation and operational advice that can be used in the implementation. © PDA, Inc. 2017.

  13. Bioavailability of five hydrophobic organic compounds to earthworms from sterile and non-sterile artificial soils.

    PubMed

    Šmídová, Klára; Kim, Sooyeon; Hofman, Jakub

    2017-07-01

    Bioaccumulation factors (BAFs) of organic pollutants to soil biota, often required by risk assessment, are mostly obtained in non-sterile laboratory-contaminated artificial soils. However, microbial degradation has been indicated by many authors to influence the fate of hydrophobic organic compounds (HOCs) in soils. A question arises if the microbial community of peat which is used for artificial soil preparation affects the measured values of BAFs. In this study the effect of soil microorganisms on bioavailability of HOCs was studied and a portion of each soil was sterilized by gamma irradiation. Results indicated that the sterilization process significantly affected the fate of polycyclic aromatic hydrocarbons (PAHs; phenanthrene and pyrene) and increased bioavailability of these compounds to earthworms with BAFs several times higher in the sterile soils compared to their non-sterile variants. This suggests that sterilization of soils can be used as the "worst-case scenario" for laboratory tests of toxicity or bioaccumulation of biodegradable HOCs such as PAHs. It represents a situation of limited microbial degradation resulting in higher bioavailable fractions to other organisms (e.g. invertebrates). This may be the case in soils where microbial communities face stresses caused by contamination or land management. The bioavailability of chlorinated HOCs (lindane, 4,4'-DDT and PCB 153) was not affected by sterilization, as their BAFs were similar in the sterile and non-sterile soils during the experiment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. SURVEY ON PREVACUUM HIGH-PRESSURE STEAM STERILIZERS.

    PubMed

    DARMADY, E M; DREWETT, S E; HUGHES, K E

    1964-03-01

    None of the 10 prevacuum high-pressure sterilizers of different makes tested was able to produce and maintain the conditions advocated by the Medical Research Council working party on high-pressure steam sterilizers (1959) or by Knox and Penikett (1958) with the result that steam did not penetrate adequately the single challenge load and it was not sterilized. The sterilization of ;group drums' of various sizes and contents was erratic and tended to give operators a false sense of security. An alarming number of minor engineering faults were present in seven out of 10 machines tested and they require very much more skilled maintenance than is being given at the moment. The possibility of centralizing sterilizers to central sterile supply departments and placing them under the care of a regional engineer cannot be too highly recommended. The presence of undetected ;leaks' and a failure to draw a prevacuum of 20 mm. even with a steam burst interferes with sterilization of a challenge load. A leak test should be performed twice daily and should not exceed more than 1 mm. in one minute at 20 mm. absolute. The centre of the load should be monitored by crossed tapes or Brownes tubes in each sterilizing cycle. Although the challenge load was sterilized when the chamber was filled to capacity, a more reliable cycle consisting of a double prevacuum of 20 mm. or more with intermediate steam burst to 10 lb. ensured the sterilizing of a single challenge load, which could be adequately controlled by the chamber drain temperature.

  15. The Procuring and Processing of Human Cadaveric Bone Marrow

    DTIC Science & Technology

    1990-01-01

    in all packs, along with a tube containing Bacillus stearothermophilus spores. At the completion of the sterilization cycle the indicator strips are...5 Sterilizer Quality Control............................................... 5 Operating Room Cultures...9 The Preparation of Sterile Tables and Trays................................. 9 Sterile linen supplies

  16. Continuous-sterilization system that uses photosemiconductor powders. [Escherichia coli

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsunaga, T.; Tomoda, R.; Nakajima, T.

    1988-06-01

    We report a novel photochemical sterilization system in which Escherichia coli cells were sterilized with photosemiconductor powders (titanium oxide). For sterilization that could be used in practice, it was necessary to separate the TiO/sub 2/ powders from the cell suspension. Therefore, semiconductor powders were immobilized on acetylcellulose membranes. We constructed a continuous-sterilization system consisting of TiO/sub 2/-immobilized acetylcellulose membrane reactor, a mercury lamp, and a masterflex pump. As a result, under the various sterilization conditions examined, E.coli (10/sup 2/ cells per ml) was sterilized to < 1% survival when the cell suspension flowed in this system at a mean residencemore » time of 16.0 min under irradiation (1800 microeinsteins/m/sup 2/ per s). We found that this system was reusable.« less

  17. Expression of sunflower cytoplasmic male sterility-associated open reading frame, orfH522 induces male sterility in transgenic tobacco plants.

    PubMed

    Nizampatnam, Narasimha Rao; Doodhi, Harinath; Kalinati Narasimhan, Yamini; Mulpuri, Sujatha; Viswanathaswamy, Dinesh Kumar

    2009-03-01

    Sterility in the universally exploited PET1-CMS system of sunflower is associated with the expression of orfH522, a novel mitochondrial gene. Definitive evidence that ORFH522 is directly responsible for male sterility is lacking. To test the hypothesis that ORFH522 is sufficient to induce male sterility, a set of chimeric constructs were developed. The cDNA of orfH522 was cloned in-frame with yeast coxIV pre-sequence, and was expressed under tapetum-specific promoter TA29 (construct designated as TCON). For developing control vectors, orfH522 was cloned without the transit peptide under TA29 promoter (TON) or orfH522 was cloned with or without transit peptide under the constitutive CaMV35S promoter (SCOP and SOP). Among several independent transformants obtained with each of the gene cassettes, one third of the transgenics (6/17) with TCON were completely male sterile while more than 10 independent transformants obtained with each of the control vectors were fertile. The male sterile plants were morphologically similar to fertile plants, but had anthers that remained below the stigmatic surface at anthesis. RT-PCR analysis of the sterile plants confirmed the anther-specific expression of orfH522 and bright-field microscopy demonstrated ablation of the tapetal cell layer. Premature DNA fragmentation and programmed cell death was observed at meiosis stage in the anthers of sterile plants. Stable transmission of induced male sterility trait was confirmed in test cross progeny. This constitutes the first report at demonstrating the induction of male sterility by introducing orfH522 gene that could be useful for genetic engineering of male sterility.

  18. Evaluation of steam penetration and sterilization of natural latex wraps.

    PubMed

    Rossanese, Matteo; Gasson, James; Barker, Colin; Bowlt, Kelly

    2014-11-01

    To evaluate the efficacy of steam and ethylene oxide (EtO) sterilization of Vetrap™ bandages. Prospective experimental study. Vetrap™ bandages (n = 70; 35 as supplied by the manufacturer, 35 unwound and tightly rewound). Vetrap™ bandage rolls (n = 60) marked with a 1 cm square were inoculated with 0.1 mL Geobacillus stearothermophilus spores, packaged in a pouch together with independent sterilization indicators and assigned into 3 sub-groups for sterilizer type: dynamic air removal, gravity displacement, and bench-top pre-vacuum and further sub-divided into 2 sterilization temperatures. Vetrap™ bandages rolls (n = 10) were inoculated with 0.1 mL Bacillus atrophaeus spores in the same manner and underwent EtO sterilization. After sterilization, the 1 cm marked square was aseptically resected to the level of the cardboard tube and enriched in a flask containing 10 mL tryptic soy broth for 24 hours at 60°C for G. stearothermophilus and 37°C for B. atrophaeus. Aliquots were subsequently plated on a Petri dish of tryptic soy agar and incubated at 60°C for G. stearothermophilus and 37°C for B. atrophaeus for 24 hours. Samples were scored positive if colonies of indicator organism were present on the nutrient agar after 24 hours. Three Vetrap™ bandages yielded post-sterilization growth of G. stearothermophilus: 2 from the dynamic air removal sterilizer at 134°C for 3.5 minutes, and 1 from the bench-top pre-vacuum sterilizer at 121°C for 15 minutes. After EtO sterilization, no positive samples were detected. Steam sterilization may be incomplete for Vetrap™ bandages whereas EtO showed complete destruction of resistant bacterial spores. © Copyright 2014 by The American College of Veterinary Surgeons.

  19. Research progress on the effect of microwave sterilization on agricultural products quality

    NASA Astrophysics Data System (ADS)

    Zhu, Xiang-hao; Yang, Yu-xia; Duan, Zhen-hua

    2018-02-01

    Different sterilization methods have different effects on the quality of agricultural products, microwave sterilization inhibited or eliminated microorganism by the use of microwave thermal effects and non-thermal. In this paper, the effects of microwave sterilization on the quality of fruits and vegetables, dairy, meat, grain, aquatic products and other agricultural products were introduced, and the possible development trends of microwave sterilization in agricultural products processing application were put forward.

  20. Using high-temperature formaldehyde sterilization as a model for studying gaseous sterilization.

    PubMed

    Mosley, Gregg A

    2008-01-01

    This study uses the high-temperature formaldehyde sterilization system provided by the Harvey Chemiclave, manufactured by Barnstead Thermolyne Corporation (Dubuque, IA), as a model to investigate certain phenomena associated with gaseous chemical sterilization systems. Although formaldehyde sterilization presents some unique and complex system attributes, the current studies provide helpful insights into general sterilization methods by chemicals in the gaseous state. Both population recovery and fraction negative (FN) techniques were used to assay surviving populations from biological indicators of the organism Geobacillus stearothermophilus following exposure to incremental Chemiclave cycles. Models 5500 and 6000 of the Barnstead/Thermolyne Chemiclave were used in the study. Reusable instruments such as scalers, explorers, and various hinged pieces were tested in minimum versus maximum load studies. Population recovery study results demonstrated that lethality rates increase with time throughout the Chemiclave sterilization process and that there are significant variations in lethality according to load location. The population recovery data in conjunction with the FN studies and temperature data confirm that one-half the full-cycle time is not a good estimator of one-half the full-cycle lethality because lethality curves are concave downward and lethality varies by load location. This conclusion can also be applied to other types of gaseous, chemical sterilization such as ethylene oxide. The work outlined in this study was a result of investigations into the parameters affecting formaldehyde chemical vapor sterilization with the Harvey Chemiclave sterilizer. During these studies, it became apparent that results clearly depicted the effects of continued acceleration of the rate of microbial lethality, as well as variations in delivered lethality as a function of position in the sterilizer load. This publication focuses on these observations because they are important considerations for understanding general concepts of sterilization efficacy in process applications. Erroneous conclusions can be drawn when one evaluates sterilization without a thorough understanding of affecting variables.

  1. Factors associated with sterilization use among women leaving a U.S. jail: a mixed methods study.

    PubMed

    Ramaswamy, Megha; Kelly, Patricia J

    2014-07-31

    Despite the high rates of reported sterilization use among women who have spent time in correctional facilities, little is known about the context in which women in this population choose this option. The objective of our study was to use both quantitative and qualitative methods to understand factors associated with sterilization use among women leaving a U.S. jail. We administered a cross-sectional survey with 102 jailed women who were participating in a study about contraceptive use after release from jail, and then conducted semi-structured interviews with 29 of those women after their release from jail. We used logistic regression and analytic induction to assess factors associated with self-reported sterilization use. In our cross-sectional survey, one-third of our sample reported a history of sterilization use. Controlling for age and past pregnancies, the only factor associated with sterilization use was physical abuse history before age 16. In semi-structured interviews, we found that women's primary motivation for sterilization was the desire to limit childbearing permanently, in some cases where other contraceptive methods had failed them. The decision for sterilization was generally supported by family, partners, and providers. Many women who opted for sterilization expressed financial concern about supporting children and/or reported family histories of sterilization. The decision to use the permanent method of sterilization as a contraceptive method is a complex one. Results from this study suggest that while explicit coercion may not be a factor in women's choice for sterilization, interpersonal relationship histories, negative experiences with contraceptives, and structural constraints, such as financial concerns and ongoing criminal justice involvement, seem to influence sterilization use among the vulnerable group of women with criminal justice histories. Public health programs that connect women to reproductive health services should acknowledge constraints on contraceptive decision-making in vulnerable populations.

  2. Multilevel Perspectives on Female Sterilization in Low-Income Communities in Mumbai, India.

    PubMed

    Brault, Marie A; Schensul, Stephen L; Singh, Rajendra; Verma, Ravi K; Jadhav, Kalpita

    2016-09-01

    Surgical sterilization is the primary method of contraception among low-income women in India. This article, using qualitative analysis of key informant, in-depth interviews, and quantitative analyses, examines the antecedents, process, and outcomes of sterilization for women in a low-income area in Mumbai, India. Family planning policies, socioeconomic factors, and gender roles constrain women's reproductive choices. Procedures for sterilization rarely follow protocol, particularly during pre-procedure counseling and consent. Women who choose sterilization often marry early, begin conceiving soon after marriage, and reach or exceed ideal family size early due to problems in accessing reversible contraceptives. Despite these constraints, this study indicates that from the perspective of women, the decision to undergo sterilization is empowering, as they have fulfilled their reproductive duties and can effectively exercise control over their fertility and sexuality. This empowerment results in little post-sterilization regret, improved emotional health, and improved sexual relationships following sterilization. © The Author(s) 2015.

  3. System for creating on site, remote from a sterile environment, parenteral solutions

    NASA Technical Reports Server (NTRS)

    Finley, Mike (Inventor); Scharf, Mike (Inventor); Packard, Jeff (Inventor); Kipp, Jim (Inventor); Dudar, Tom (Inventor); Owens, Jim (Inventor); Bindokas, Al (Inventor)

    1996-01-01

    The present invention provides a system and method for creating on site, remote from a sterile environment, parenteral solutions in large volume parenteral containers for intravenous administration to a patient. In an embodiment, this system comprises an empty large volume container including at least one port for accessing an interior of the container. The port includes a sterilizing filter for sterilizing a fluid fed through the port into the container. A second container is provided including a solute and having means for coupling the second container to the large volume container and thereby providing fluid communication therebetween allowing the solute to be received within the interior of the container. A sterile water source is also provided including means for placing the sterile water source in fluid communication with the port and allowing water to flow from the sterile water source into the interior of the container. This allows the solute, and sterile water that has been fed through the filter, to create a parenteral solution in the large volume parenteral container.

  4. Reliability of biologic indicators in a mail-return sterilization-monitoring service: a review of 3 years.

    PubMed

    Andrés, M T; Tejerina, J M; Fierro, J F

    1995-12-01

    Most mail-return sterilization-monitoring services use spore strips to test sterilizers in dental clinics, but factors such as delay caused by mailing to the laboratory could cause false negatives. The aims of this study were to determine the influence of poststerilization time and temperature on the biologic indicator recovery system and to evaluate sterilization failure and its possible causes in dental clinics subscribing to a mail-return sterilization-monitoring service. Spore strips used in independent tests revealed the poststerilization time and temperature after a 7-day delay to have no significant influence. Sixty-six dental clinics that received quarterly biologic indicators to evaluate the effectiveness of their sterilizers had sterilization failure rates of 28.7% in 1992, 18.1% in 1993, and 9.1% in 1994, a statistically significant decrease in sterilization failure during the 3-year period. The usual causes of failure were operator error in wrapping of instruments, loading, operating temperature, or exposure time.

  5. Floating rGO-based black membranes for solar driven sterilization.

    PubMed

    Zhang, Yao; Zhao, Dengwu; Yu, Fan; Yang, Chao; Lou, Jinwei; Liu, Yanming; Chen, Yingying; Wang, Zhongyong; Tao, Peng; Shang, Wen; Wu, Jianbo; Song, Chengyi; Deng, Tao

    2017-12-14

    This paper presents a new steam sterilization approach that uses a solar-driven evaporation system at the water/air interface. Compared to the conventional solar autoclave, this new steam sterilization approach via interfacial evaporation requires no complex system design to bear high steam pressure. In such a system, a reduced graphene oxide/polytetrafluoroethylene composite membrane floating at the water/air interface serves as a light-to-heat conversion medium to harvest and convert incident solar light into localized heat. Such localized heat raises the temperature of the membrane substantially and helps generate steam with a temperature higher than 120 °C. A sterilization device that takes advantage of the interfacial solar-driven evaporation system was built and its successful sterilization capability was demonstrated through both chemical and biological sterilization tests. The interfacial evaporation-based solar driven sterilization approach offers a potential low cost solution to meet the need for sterilization in undeveloped areas that lack electrical power but have ample solar radiation.

  6. Factors Related to Intention to Undergo Female Sterilization Among Married Women in Rural Kathmandu, Nepal

    PubMed Central

    Nanthamongkolchai, Sutham; Pitikultang, Supachai

    2016-01-01

    Background: Sterilization is most widely used fertility regulation method in Nepal. However, prevalence of uptake of female sterilization in central hilly region is less than the national average. The objective of the study was to explore the number and factors related to intention of married women to undergo female sterilization in rural Kathmandu which lies within central hilly region. Materials and Methods: This is a community based cross-sectional survey research conducted in rural area of Kathmandu valley. Two hundred and forty currently married women with at least one child of any age were interviewed using a structured pre-tested questionnaire. Results: More than four-fifth of the respondents intended to undergo sterilization. Almost two-third of them wanted to limit their family size by taking this option. More than one-third of women not-intending to undergo sterilization feared weakness after sterilization. Age of the respondents, duration of marriage, and number of living children were significantly associated with intention to undergo sterilization. 15-24 years age group were six times more likely to have the intention for sterilization (OR 6.79, CI 2.28-20.19) compared to age 35 years and above group. Mothers with less than 3 living children are about three times more likely to have the intention to undergo sterilization (OR 2.87, CI 1.3-6.33) compared to women with more than 2 living children. Women married for 6 to 10 years were three times more likely to have the intention (OR 3.0, CI 1.09-8.27). However, gender of the living children was not associated with intention to undergo sterilization. Conclusion: There were significant numbers of women intending to undergo sterilization. Age of the mother, number of living children and the duration of marriage were found to be significantly influencing the intention to undergo sterilization. However, as intention refers to future plan, the respondents’ intention may change over time. The national family planning program also needs to identify the key factors in accepting the sterilization and target these women to increase utilization. PMID:27152235

  7. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    PubMed

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Training of residents in laparoscopic tubal sterilization: Long-term failure rates

    PubMed Central

    Rackow, Beth W.; Rhee, Maria C.; Taylor, Hugh S.

    2011-01-01

    Objectives Laparoscopic tubal sterilization with bipolar coagulation is a common and effective method of contraception, and a procedure much used to teach laparoscopic surgical skills to Obstetrics and Gynaecology residents (trainees); but it has an inherent risk of failure. This study investigated the long-term failure rate of this procedure when performed by Obstetrics and Gynaecology residents on women treated in their teaching clinics. Methods From 1991 to 1994, Obstetrics and Gynaecology residents carried out 386 laparoscopic tubal sterilizations with bipolar coagulation at Yale-New Haven Hospital. Six to nine years after the procedure, the women concerned were contacted by telephone and data were collected about sterilization failure. Results Two failures of laparoscopic tubal sterilization with bipolar coagulation were identified: an ectopic pregnancy and a spontaneous abortion. For this time period, the long-term sterilization failure rate was 1.9% (0–4.4%). Conclusions The long-term sterilization failure rate for laparoscopic tubal sterilization with bipolar coagulation performed by residents is comparable to the results of prior studies. These findings can be used to properly counsel women at a teaching clinic about the risks of sterilization failure with this procedure, and attest to the adequacy of residents’ training and supervision. PMID:18465476

  9. [Determinants of sterilization among married couples in Korea].

    PubMed

    Kim, Ju Hee; Chung, Woojin; Lee, Sunmi; Suh, Moonhee; Kang, Dae Ryong

    2007-11-01

    The purpose of this study was to examine the determinants of sterilization in South Korea. This study was based on the data from the Korea National Fertility Survey carried out in the year 2000 by the Korea Institute of Health and Social Affairs. The subjects of the analysis were 4,604 women and their husbands who were in their first marriage, in the age group of 15-49 years. The data were analyzed by multiple logistic regression analysis. Consistent with the findings of previous studies, the woman's age and the number of total children increased the likelihood of sterilization. In addition, the year of marriage had a strong positive association with sterilization. Interestingly, the number of surviving sons tended to increase the likelihood of sterilization, whereas the woman's education level and age at the time of marriage showed a negative association with sterilization. Religion, place of residence, son preference, and the husband's education level, age and type of occupation were not significant determinants of sterilization. The sex of previous children and lower level of education are distinct determinants of sterilization among women in South Korea. More studies are needed in order to determine the associations between sterilization rate and decreased fertility.

  10. The relative safety of gamma-ray, autoclave, and ethylene oxide gas sterilization of thermosetting polyurethane.

    PubMed

    Shintani, H

    1995-01-01

    Sterilization of polyurethane (PU) produces 4,4'-methylenedianiline (MDA), a known carcinogen, and various other compounds. The relationships of the components of PU to the formation of these compounds by sterilization were studied. Specimens of PU fabricated from different combinations of isocyanates and polyols were obtained from dialyzers. The molecular weight of the particular polyol was found to influence the production of MDA by sterilization. Sterilization also produced many unidentified compounds. MDA production was not always associated with the production of the other compounds. Compared with gamma-ray irradiation and ethylene oxide gas (EOG) sterilization, autoclave sterilization eluted more hydrophilic compounds. This phenomenon was significant for PUs produced from smaller-molecular-weight polyols. The combination of autoclave sterilization and a PU produced from a larger-molecular-weight polyol is recommended to minimize the production of potentially toxic compounds. Of the techniques studied, EOG sterilization produced the least amounts of MDA and the other compounds, but the residue of EOG is itself problematic. The risk posed by the amounts of MDA extracted was not significant, but the biological safety of the other compounds remains to be determined.

  11. Genetic basis of hybrid male sterility among three closely related species of Drosophila.

    PubMed

    Mishra, Paras Kumar; Singh, B N

    2005-05-01

    The genetic basis of hybrid male sterility among three closely related species, Drosophila bipectinata, D. parabipectinata and D. malerkotliana has been investigated by using backcross analysis methods. The role of Y chromosome, major hybrid sterility (MHS) genes (genetic factors) and cytoplasm (non-genetic factor) have been studied in the hybrids of these three species. In the species pair, bipectinata--parabipectinata, Y chromosome introgression of parabipectinata in the genomic background of bipectinata and the reciprocal Y chromosome introgression were unsuccessful as all males in second backcross generation were sterile. Neither MHS genes nor cytoplasm was found important for sterility. This suggests the involvement of X-Y, X-autosomes or polygenic interactions in hybrid male sterility. In bipectinata--malerkotliana and parabipectinata--malerkotliana species pairs, Y chromosome substitution in reciprocal crosses did not affect male fertility. Backcross analyses also show no involvement of MHS genes or cytoplasm in hybrid male sterility in these two species pairs. Therefore, X- autosome interaction or polygenic interaction is supposed to be involved in hybrid male sterility in these two species pairs. These findings also provide evidence that even in closely related species, genetic interactions underlying hybrid male sterility may vary.

  12. Genome-wide dissection of hybrid sterility in Drosophila confirms a polygenic threshold architecture.

    PubMed

    Morán, Tomás; Fontdevila, Antonio

    2014-01-01

    To date, different studies about the genetic basis of hybrid male sterility (HMS), a postzygotic reproductive barrier thoroughly investigated using Drosophila species, have demonstrated that no single major gene can produce hybrid sterility without the cooperation of several genetic factors. Early work using hybrids between Drosophila koepferae (Dk) and Drosophila buzzatii (Db) was consistent with the idea that HMS requires the cooperation of several genetic factors, supporting a polygenic threshold (PT) model. Here we present a genome-wide mapping strategy to test the PT model, analyzing serially backcrossed fertile and sterile males in which the Dk genome was introgressed into the Db background. We identified 32 Dk-specific markers significantly associated with hybrid sterility. Our results demonstrate 1) a strong correlation between the number of segregated sterility markers and males' degree of sterility, 2) the exchangeability among markers, 3) their tendency to cluster into low-recombining chromosomal regions, and 4) the requirement for a minimum number (threshold) of markers to elicit sterility. Although our findings do not contradict a role for occasional major hybrid-sterility genes, they conform more to the view that HMS primarily evolves by the cumulative action of many interacting genes of minor effect in a complex PT architecture.

  13. Heat-sterilized PD fluid blocks leukocyte adhesion and increases flow velocity in rat peritoneal venules.

    PubMed

    Jonasson, P; Bagge, U; Wieslander, A; Braide, M

    1996-01-01

    Data from cell culture experiments indicate that heat sterilization of peritoneal dialysis (PD) fluids produces cytotoxic glucose degradation products. The present vital microscopic study investigated the effects of different sterilization methods on the biocompatibility of PD fluids. Thus, heat-sterilized (commercially obtained and experimentally produced) and filter-sterilized PD fluids (pH = 5.30-5.40; 1.5% glucose) were compared with Tyrode buffer, with respect to the effects on microvascular blood flow velocity and leukocyte adhesion in the rat mesentery. Exteriorization of the mesentery produced a mild inflammation, known from the literature and characterized by the adhesive rolling of leukocytes along venular walls. Superfusion of the mesentery with filter-sterilized PD fluid had no significant effects on leukocyte rolling or flow velocity in venules 25-40 microns in diameter compared with buffer superfusion. Heat-sterilized PD fluid decreased the concentration of rolling leukocytes and increased flow velocity significantly, as compared with buffer and filter-sterilized PD fluid. The results indicate that heat sterilization of PD fluids produces substances that interact with microvascular tone and leukocyte-endothelial adhesion, which hypothetically could impair the acute, granulocyte-mediated defense against bacterial infections.

  14. [Evaluation of the influence of sterilization method on the stability of carboxymethyl cellulose wound dressing].

    PubMed

    Muselík, Jan; Wojnarová, Lenka; Masteiková, Ruta; Sopuch, Tomáš

    2013-04-01

    Carboxymethyl cellulose, especially its sodium salt, is a versatile pharmaceutical excipient. From a therapeutic point of view, sodium salt of carboxymethyl cellulose is used in the production of modern wound dressings to allow moist wound healing. Wound dressings must be sterile and stable throughout their shelf life and have to be able to withstand different temperature conditions. At the present time, a number of sterilization methods are available. In the case of polymeric materials, the selected sterilization process must not induce any changes in the polymer structure, such as polymer chains cleavage, changes in cross-linking, etc. This paper evaluates the influence of different sterilization methods (γ-radiation, β-radiation, ethylene oxide) on the stability of carboxymethyl cellulose and the results of long-term and accelerated stability testing. Evaluation of samples was performed using size-exclusion chromatography. The obtained results showed that ethylene oxide sterilization was the least aggressive variant of the sterilization methods tested. When the γ-radiation sterilization was used, the changes in the size of the carboxymethyl cellulose molecule occurred. In the course of accelerated and long term stability studies, no further degradation changes were observed, and thus sterilized samples are suitable for long term storage.

  15. Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.

    PubMed

    Basu, Debabrata

    Wet pack after steam sterilization process that means there are surely obtain millions of microorganisms that can breed and multiply rapidly and objects are unsterile and can never be used for further procedure. There are many reasons behind the wet pack occurrences after autoclaving like poor quality of wrapping materials, faulty valves of rigid container, faulty loading and packaging technique, poor steam quality, sterilizer malfunction and may be design related problems in CSSD sterile storage area. Cause of wet pack after steam sterilization processes may occur severe problems because of wasted time and effort, increased work load, increased cost, potentially contaminated instruments, infection risk to the patient, poor patient outcomes and delayed or cancellation of procedures. But such wet pack scenario can be avoided by various methods by using good steam (water) quality, performing periodic maintenance of the Autoclaves, avoidance of sterilizer overloading, allowing adequate post sterilization time to cool down the materials to room temperature, using good quality wrapping materials, properly maintain temperature and humidity of sterile storage area etc. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  16. Dog and cat management through sterilization: Implications for population dynamics and veterinary public policies.

    PubMed

    Dias, Ricardo Augusto; Baquero, Oswaldo Santos; Guilloux, Aline Gil Alves; Moretti, Caio Figueiredo; de Lucca, Tosca; Rodrigues, Ricardo Conde Alves; Castagna, Cláudio Luiz; Presotto, Douglas; Kronitzky, Yury Cezar; Grisi-Filho, José Henrique Hildebrand; Ferreira, Fernando; Amaku, Marcos

    2015-11-01

    The present study aimed to compare different sterilization scenarios allowing the adoption of the most adequate strategy to control owned dog and cat population sizes as the official veterinary public policy for animal control in an urban area of Campinas municipality, Brazil. To achieve this goal, the vital parameters of the owned pet population were measured in a neighborhood of Campinas called Jardim Vila Olimpia through questionnaires used in two census studies performed in February 2012 and June 2013. Different hypothetical sterilization scenarios were compared with the scenario of a single sterilization campaign performed in the study area between the census studies. Using a deterministic mathematical model, population dynamics were simulated for these different scenarios. We have observed that for both owned dogs and cats, the impact on the population size achieved by a single sterilization campaign would be diluted over the years, equating to the impact achieved by the usual sterilization rate practiced before the sterilization campaign yearly. Moreover, using local and global sensitivity analyses, we assessed the relative influence on animal population evolution of each vital parameter used in the mathematical models. The more influential parameters for both species were the carrying capacity of the environment and sterilization rates of males and females (for both species). We observed that even with sterilizing 100% of the intact animals annually, it would not be possible to obtain proportions greater than 86% and 88% of sterilized dogs and cats, respectively, after 20 years due to the high introduction of new intact animals. There is no public dog and cat sterilization service in place in the city, and sporadic and local sterilization campaigns are performed with a prior communication to the owners to bring their animals to be sterilized in a selected veterinary facility. If a sterilization campaign was performed annually in the study area, it would have the most favorable cost effectiveness ratio after 20 years compared to the scenarios of 50% and 100% sterilization of intact animals annually. These results allowed the veterinary public policy stakeholders to make decisions based on scientific evidence to implement adequate control of dog and cat populations in urban areas, aiming to reduce zoonosis transmission to humans and other problems associated with uncontrolled animal populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Evaluation of Ophthalmic Surgical Instrument Sterility Using Short-Cycle Sterilization for Sequential Same-Day Use.

    PubMed

    Chang, David F; Hurley, Nikki; Mamalis, Nick; Whitman, Jeffrey

    2018-03-27

    The common practice of short-cycle sterilization for ophthalmic surgical instrumentation has come under increased regulatory scrutiny. This study was undertaken to evaluate the efficacy of short-cycle sterilization processing for consecutive same-day cataract procedures. Testing of specific sterilization processing methods by an independent medical device validation testing laboratory. Phaco handpieces from 3 separate manufacturers were tested along with appropriate biologic indicators and controls using 2 common steam sterilizers. A STATIM 2000 sterilizer (SciCan, Canonsburg, PA) with the STATIM metal cassette, and an AMSCO Century V116 pre-vacuum sterilizer (STERIS, Mentor, OH) using a Case Medical SteriTite container (Case Medical, South Hackensack, NJ) rigid container were tested using phaco tips and handpieces from 3 different manufacturers. Biological indicators were inoculated with highly resistant Geobacillus stearothermophilus, and each sterility verification test was performed in triplicate. Both wrapped and contained loads were tested with full dry cycles and a 7-day storage time to simulate prolonged storage. In adherence with the manufacturers' instructions for use (IFU), short cycles (3.0-3.5-minute exposure times) for unwrapped and contained loads were also tested after only 1 minute of dry time to simulate use on a consecutive case. Additional studies were performed to demonstrate whether any moisture present in the load containing phaco handpieces postprocessing was sterile and would affect the sterility of the contents after a 3-minute transit/storage time. This approximated the upper limit of time needed to transfer a containment device to the operating room. Presence or absence of microbial growth from cultured test samples. All inoculated test samples from both sterilizers were negative for growth of the target organism whether the full dry phase was interrupted or not. Pipetted postprocessing moisture samples and swabs of the handpieces were also negative for growth after a 3-minute transit/storage time. These studies support the use of unwrapped, short-cycle sterilization that adheres to the IFU of these 2 popular Food and Drug Administration-cleared sterilizers for sequential same-day cataract surgeries. A full drying phase is not necessary when the instruments are kept within the covered sterilizer containment device for prompt use on a sequential case. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Gamma inert sterilization: a solution to polyethylene oxidation?

    PubMed

    Medel, Francisco J; Kurtz, Steven M; Hozack, William J; Parvizi, Javad; Purtill, James J; Sharkey, Peter F; MacDonald, Daniel; Kraay, Matthew J; Goldberg, Victor; Rimnac, Clare M

    2009-04-01

    In the 1990s, oxidation was found to occur in ultra-high molecular weight polyethylene total joint replacement components following gamma irradiation and prolonged shelf aging in air. Orthopaedic manufacturers developed barrier packaging to reduce oxidation during and after radiation sterilization. The present study explores the hypothesis that polyethylene components sterilized in a low-oxygen environment undergo similar in vivo oxidative mechanisms as inserts sterilized in air. In addition, the potential influence of the different sterilization processes on the wear performance of the polyethylene components was examined. An analysis of oxidation, wear, and surface damage was performed for forty-eight acetabular liners and 123 tibial inserts. The mean implantation time was 12.3+/-3.7 years for thirty-one acetabular liners that had been gamma sterilized in air and 4.0+/-2.5 years for the seventeen acetabular liners that had been gamma sterilized in inert gas. The mean implantation time was 11.0+/-3.2 years for the twenty-six tibial inserts that had been sterilized in air and 2.8+/-2.2 years for the ninety-seven tibial inserts that had been gamma sterilized in inert gas. Oxidation and hydroperoxide levels were characterized in loaded and unloaded regions of the inserts. Measurable oxidation and oxidation potential were observed in all cohorts. The oxidation and hydroperoxide levels were regional. Surfaces with access to body fluids were more heavily oxidized than protected bearing surfaces were. This variation appeared to be greater in historical (gamma-in-air-sterilized) components. Regarding wear performance, historical and conventional acetabular liners showed similar wear penetration rates, whereas a low incidence of delamination was confirmed for the conventional tibial inserts in the first decade of implantation. The present study explores the impact of industry-wide changes in sterilization practices for polyethylene. We found lower oxidation and oxidation potential in the conventional acetabular liners and tibial inserts that had been gamma sterilized in inert gas as compared with the historical components that had been gamma sterilized in air. However, we also found strong evidence that conventional components undergo mechanisms of in vivo oxidation similar to those observed following gamma irradiation in air. In addition, gamma sterilization in inert gas did not provide polyethylene with a significant improvement in terms of wear resistance as compared with gamma sterilization in air, except for a lower incidence of delamination in the first decade of implantation for tibial inserts.

  19. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50... GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207 Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or...

  20. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a...

  1. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  2. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 1 2014-10-01 2014-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare Department of Health and Human Services GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  3. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  4. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 1 2013-10-01 2013-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  5. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 1 2012-10-01 2012-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  6. 21 CFR 880.6885 - Liquid chemical sterilants/high level disinfectants.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Liquid chemical sterilants/high level... and Personal Use Miscellaneous Devices § 880.6885 Liquid chemical sterilants/high level disinfectants. (a) Identification. A liquid chemical sterilant/high level disinfectant is a germicide that is...

  7. 21 CFR 880.6885 - Liquid chemical sterilants/high level disinfectants.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Liquid chemical sterilants/high level... and Personal Use Miscellaneous Devices § 880.6885 Liquid chemical sterilants/high level disinfectants. (a) Identification. A liquid chemical sterilant/high level disinfectant is a germicide that is...

  8. 21 CFR 880.6885 - Liquid chemical sterilants/high level disinfectants.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Liquid chemical sterilants/high level... and Personal Use Miscellaneous Devices § 880.6885 Liquid chemical sterilants/high level disinfectants. (a) Identification. A liquid chemical sterilant/high level disinfectant is a germicide that is...

  9. 21 CFR 880.6885 - Liquid chemical sterilants/high level disinfectants.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Liquid chemical sterilants/high level... and Personal Use Miscellaneous Devices § 880.6885 Liquid chemical sterilants/high level disinfectants. (a) Identification. A liquid chemical sterilant/high level disinfectant is a germicide that is...

  10. 21 CFR 880.6885 - Liquid chemical sterilants/high level disinfectants.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Liquid chemical sterilants/high level... and Personal Use Miscellaneous Devices § 880.6885 Liquid chemical sterilants/high level disinfectants. (a) Identification. A liquid chemical sterilant/high level disinfectant is a germicide that is...

  11. Reversibility of female sterilization.

    PubMed

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their results of SR according to the original sterilization procedure. The most commonly performed sterilization (Pomeroy) was the most frequently reported to have undergone a reversal attempt, with a 50% success rate based on term or intrauterine pregnancies. Electrocoagulation was the next most frequent technique for reversal, with a 41% success rate. The less destrictive mechanical tehcniques, clip and band, had a reversal rate of 84% and 72%, respectively. A table summarizes sterilization procedures devised for reversibility in women. A women seeking sterilization should be advised that sterilization is permanent if no further tubal surgery is performed and that reversal is possible but involves a major and expensive operation.

  12. Apparatus Circulates Sterilizing Gas

    NASA Technical Reports Server (NTRS)

    Cross, John H.; Schwarz, Ray P.

    1991-01-01

    Apparatus circulates sterilizing gas containing ethylene oxide and chlorofluorocarbon through laboratory or medical equipment. Confines sterilizing gas, circulating it only through parts to be treated. Consists of two units. One delivers ethylene oxide/chlorofluorocarbon gas mixture and removes gas after treatment. Other warms, humidifies, and circulates gas through equipment to be treated. Process provides reliable sterilization with negligible residual toxicity from ethylene oxide. Particularly suitable for sterilization of interiors of bioreactors, heart/lung machines, dialyzers, or other equipment including complicated tubing.

  13. [Proposal of a costing method for the provision of sterilization in a public hospital].

    PubMed

    Bauler, S; Combe, C; Piallat, M; Laurencin, C; Hida, H

    2011-07-01

    To refine the billing to institutions whose operations of sterilization are outsourced, a sterilization cost approach was developed. The aim of the study is to determine the value of a sterilization unit (one point "S") evolving according to investments, quantities processed, types of instrumentation or packaging. The time of preparation has been selected from all sub-processes of sterilization to determine the value of one point S. The time of preparation of sterilized large and small containers and pouches were raised. The reference time corresponds to one bag (equal to one point S). Simultaneously, the annual operating cost of sterilization was defined and divided into several areas of expenditure: employees, equipments and building depreciation, supplies, and maintenance. A total of 136 crossing times of containers were measured. Time to prepare a pouch has been estimated at one minute (one S). A small container represents four S and a large container represents 10S. By dividing the operating cost of sterilization by the total number of points of sterilization over a given period, the cost of one S can be determined. This method differs from traditional costing method in sterilizing services, considering each item of expenditure. This point S will be the base for billing of subcontracts to other institutions. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  14. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    PubMed Central

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  15. Surgical sterilization, regret, and race: contemporary patterns.

    PubMed

    Shreffler, Karina M; McQuillan, Julia; Greil, Arthur L; Johnson, David R

    2015-03-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4592 women ages 25-45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Modeling the suppression of sea lamprey populations by the release of sterile males or sterile females

    USGS Publications Warehouse

    Klassen, Waldemar; Adams, Jean V.; Twohey, Michael B.

    2004-01-01

    The suppressive effects of trapping adult sea lampreys, Petromyzon marinus Linnaeus, and releasing sterile males (SMRT) or females (SFRT) into a closed system were expressed in deterministic models. Suppression was modeled as a function of the proportion of the population removed by trapping, the number of sterile animals released, the reproductive rate and sex ratio of the population, and (for the SFRT) the rate of polygyny. Releasing sterile males reduced populations more quickly than did the release of sterile females. For a population in which 30% are trapped, sterile animals are initially released at ratio of 10 sterile to 1 fertile animal, 5 adult progeny are produced per fertile mating, 60% are male, and males mate with an average of 1.65 females, the initial population is reduced 87% by SMRT and 68% by SFRT in one generation. The extent of suppression achieved is most sensitive to changes in the initial sterile release ratio. Given the current status of sea lamprey populations and trapping operations in the Great Lakes, the sterile-male-release technique has the best chance for success on a lake-wide basis if implemented in Lake Michigan. The effectiveness of the sterile-female-release technique should be investigated in a controlled study. Advancing trapping technology should be a high priority in the near term, and artificial rearing of sea lampreys to the adult stage should be a high priority in the long term. The diligent pursuit of sea lamprey suppression over a period of several decades can be expected to yield great benefits.

  17. Nitrogen Dioxide Sterilization in Low-Resource Environments: A Feasibility Study

    PubMed Central

    Avasthi, Trisha; Trilling, Ariel

    2015-01-01

    Access to sterilization is a critical need for global healthcare, as it is one of the prerequisites for safe surgical care. Lack of sterilization capability has driven up healthcare infection rates as well as limited access to healthcare, especially in low-resource environments. Sterilization technology has for the most part been static and none of the established sterilization methods has been so far successfully adapted for use in low-resource environments on a large scale. It is evident that healthcare facilities in low-resource settings require reliable, deployable, durable, affordable, easily operable sterilization equipment that can operate independently of scarce resources. Recently commercialized nitrogen dioxide (NO2) sterilization technology was analyzed and adapted into a form factor suitable for use in low-resource environments. Lab testing was conducted in microbiological testing facilities simulating low-resource environments and in accordance with the requirements of the international sterilization standard ANSI/AAMI/ISO 14937 to assess effectiveness of the device and process. The feasibility of a portable sterilizer based on nitrogen dioxide has been demonstrated, showing that sterilization of medical instruments can occur in a form factor suitable for use in low-resource environments. If developed and deployed, NO2 sterilization technology will have the twin benefits of reducing healthcare acquired infections and limiting a major constraint for access to surgical care on a global scale. Additional benefits are achieved in reducing costs and biohazard waste generated by current health care initiatives that rely primarily on disposable kits, increasing the effectiveness and outreach of these initiatives. PMID:26098905

  18. [Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC) on the incidence of phlebitis. A randomized controlled trial].

    PubMed

    Forni, Cristiana; D'Alessandro, Fabio; Gambino, Orazio; Amodeo, Alfredo; Pignotti, Elettra; Zanotti, Enrichetta; Tremosini, Morena; Trofa, Carmela; Sabattini, Tania; Matino, Federica; Genco, Rossana; Schiavone, Miguel; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Capezzali, Daniela; Boschi, Rita; Loro, Loretta

    2012-01-01

    Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC), on the incidence of phlebitis. A randomized controlled trial. The type of dressing could contribute to the incidence of phlebitis, infiltration and accidental removals but the results of the studies are contrasting and samples are limited. To compare the effectiveness of a transparent polyurethane sterile dressing on the rate of phlebitis associated to peripheral venous catheter (PVC) vs a non sterile sticking plaster in use in current practice (standard dressing). Randomized controlled trial. Participants. 1061 PVCs (703 patients, adults and children) at a research orthopedic hospital in the north of Italy; 540 PVCs allocated to receive the sterile and 521 the standard dressing. 96 PVCs were excluded for phlebitis, 48 (9.6%) in the sterile and 48 (10.1%) in the standard dressing group, RR 0.96 (95%CI 0.697 - 1.335). Accidental removal of the PVCs was more frequent with the sterile dressing (9.6% vs 6.3%) but the number of catheters removed without complications was larger in the standard dressing group (48.9% vs 54.9% P=0.0503). Eighty-five PVCs were replaced for detachment of the dressing (50, 9.2% sterile and 35, 6.7% standard dressing). The cheapest transparent sterile dressing costs 32 cents while the standard 9 cents. A sticking non sterile plasters is not influential on the rate of phlebitis and ensures an good fix of the PVC compared the transparent sterile dressing to of polyurethane film.

  19. Factors associated with sterilization among HIV-positive US women in an urban outpatient clinic.

    PubMed

    Raziano, V T; Smoots, A N; Haddad, L B; Wall, K M

    2017-05-01

    This cross-sectional study sought to determine factors associated with sterilization among HIV-positive US women. HIV-positive women aged 18-45 completed an Audio Computer Assisted Self Interview (ACASI) questionnaire. Chi-square tests and multivariable logistic regression evaluated factors associated with sterilization. The median age of the 187 participants was 37, the majority had at least a high school education, and 88% were African American. Nearly a quarter (22%) of women had undergone sterilization at an average age of 25; of these women, 71% cited their HIV-positive status as an important factor in deciding to have a tubal ligation, 22% expressed desire for future children, 32% reported sterilization regret, and 20% reported feeling pressure to undergo sterilization. In multivariable analysis, factors significantly associated with sterilization included non-African American race, no desire for future pregnancy, having heard of any birth control methods making it harder to get pregnant in the future, belief that women should take a break from hormonal methods every few years, and having had a child born with HIV. While almost a quarter of this HIV-positive group was sterilized, many during the height of the early HIV epidemic, a large proportion of sterilized women expressed sterilization regret. Counseling messages for sterilized HIV-positive women should be sensitive to the fact that women may have regret regarding a decision that, in some cases, may historically have been part of provider recommendations to prevent vertical transmission of HIV. Improved knowledge about contraceptive options such as the IUD and implant is needed among HIV-positive women.

  20. Survey on prevacuum high-pressure steam sterilizers

    PubMed Central

    Darmady, E. M.; Drewett, S. E.; Hughes, K. E. A.

    1964-01-01

    None of the 10 prevacuum high-pressure sterilizers of different makes tested was able to produce and maintain the conditions advocated by the Medical Research Council working party on high-pressure steam sterilizers (1959) or by Knox and Penikett (1958) with the result that steam did not penetrate adequately the single challenge load and it was not sterilized. The sterilization of `group drums' of various sizes and contents was erratic and tended to give operators a false sense of security. An alarming number of minor engineering faults were present in seven out of 10 machines tested and they require very much more skilled maintenance than is being given at the moment. The possibility of centralizing sterilizers to central sterile supply departments and placing them under the care of a regional engineer cannot be too highly recommended. The presence of undetected `leaks' and a failure to draw a prevacuum of 20 mm. even with a steam burst interferes with sterilization of a challenge load. A leak test should be performed twice daily and should not exceed more than 1 mm. in one minute at 20 mm. absolute. The centre of the load should be monitored by crossed tapes or Brownes tubes in each sterilizing cycle. Although the challenge load was sterilized when the chamber was filled to capacity, a more reliable cycle consisting of a double prevacuum of 20 mm. or more with intermediate steam burst to 10 lb. ensured the sterilizing of a single challenge load, which could be adequately controlled by the chamber drain temperature. PMID:14149935

  1. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  2. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  3. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  4. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  5. Solute-Filled Syringe For Formulating Intravenous Solution

    NASA Technical Reports Server (NTRS)

    Owens, Jim; Bindokas, AL; Dudar, Tom; Finley, Mike; Scharf, Mike

    1993-01-01

    Prefilled syringe contains premeasured amount of solute in powder or concentrate form used to deliver solute to sterile interior of large-volume parenteral (LVP) bag. Predetermined amount of sterile water also added to LVP bag through sterilizing filter, and mixed with contents of syringe, yielding sterile intravenous solution of specified concentration.

  6. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  7. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  8. The Coercive Sterilization of Aboriginal Women in Canada

    ERIC Educational Resources Information Center

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  9. The backcross sterility technique

    Treesearch

    V. C. Mastro; A. Pellegrini-Toole

    1991-01-01

    The sterile insect technique (SIT) and the induced inherited (F1) sterility technique have been investigated for a number of lepidopterous pests, including the gypsy moths. Another technique, backcross sterility, which could potentially prove as or more useful for control of pest species has been developed for the control of only one lepidopteran...

  10. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  11. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  12. Progress in development of male sterile germplasm for hybrid rice breeding

    USDA-ARS?s Scientific Manuscript database

    Currently, there are two types of male sterility mainly commercialized in hybrid rice production, three-line type or cytoplasmic male sterility (CMS) and two-line type or environmental male sterility (EMS). The great majority belongs to the CMS and there are four strategies that have been proven suc...

  13. 75 FR 8970 - Guidance for Industry on Submission of Documentation in Applications for Parametric Release of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... Veterinary Drug Products Terminally Sterilized by Moist Heat Processes; Availability AGENCY: Food and Drug... Release of Human and Veterinary Drug Products Terminally Sterilized by Moist Heat Processes.'' This... for sterile products terminally sterilized by moist heat when submitting a new drug application (NDA...

  14. [Regret of female sterilization].

    PubMed

    Öhman, Malin Charlotta; Andersen, Lars Franch

    2015-11-16

    Regret of sterilization is inversely correlated to age at the time of sterilization. The minimum age for legal sterilization in Denmark has recently been lowered to 18 years. In Denmark surgical refertilization has almost completely been replaced by in vitro fertilization (IVF). In recent literature pregnancy results after surgical refertilization are easily comparable to IVF. Refertilization may in some cases be advantageous to IVF treatment. Women requesting reversal of sterilization should be offered individualized evaluation and differentiated treatment. It is recommended that surgical refertilization is performed at very few centres.

  15. Use of gamma radiation for preparation of nutrient culture media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Speranskaya, I.D.; Tumanyan, M.A.; Mironova, L.L.

    1977-01-01

    A technique was developed for sterilization of nutrient culture media using ..gamma..-radiation. For this purpose, dry preparations were exposed to 3 to 6 Mrad radiation, then dissolved in sterile distilled water. The quality of media and solutions thus obtained is as good as that of preparations sterilized by filtration. The advantage of the proposed sterilization method is that liquid media can be rapidly prepared and dry sterile media can be stored at room temperature for long periods of time.

  16. New disinfection and sterilization methods.

    PubMed Central

    Rutala, W. A.; Weber, D. J.

    2001-01-01

    New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50). PMID:11294738

  17. Psychological long-term effects of sterilization on anxiety and depression.

    PubMed

    Luo, L; Wu, S Z; Zhu, C; Fan, Q; Liu, K; Sun, G

    1996-12-01

    Two-thousand cases (500 women and 500 men with sterilization; 500 women and 500 men without sterilization) in two counties and two cities in Sichuan, China, were investigated between 15 September 1992 and 30 April 1993. Information was obtained about their age, parity, marriage, contraceptives, social behavior, and present psychological characteristics. CES-D, SAS, and E.P.Q. scales were used to assess the depressive symptomatology, anxiety, and personality of the subjects. The results revealed that sterilization psychologically affected the depressive symptoms and anxiety under the neutral personality. In addition, depressive symptoms and anxiety were related to the subjects' age, educational level, income, operative doctors' attitudes to sterilization acceptors, and subjects' understanding of the sterilization.

  18. Optimizing sterilization logistics in hospitals.

    PubMed

    van de Klundert, Joris; Muls, Philippe; Schadd, Maarten

    2008-03-01

    This paper deals with the optimization of the flow of sterile instruments in hospitals which takes place between the sterilization department and the operating theatre. This topic is especially of interest in view of the current attempts of hospitals to cut cost by outsourcing sterilization tasks. Oftentimes, outsourcing implies placing the sterilization unit at a larger distance, hence introducing a longer logistic loop, which may result in lower instrument availability, and higher cost. This paper discusses the optimization problems that have to be solved when redesigning processes so as to improve material availability and reduce cost. We consider changing the logistic management principles, use of visibility information, and optimizing the composition of the nets of sterile materials.

  19. The perplexing links between contraceptive sterilization and (dis)advantage in ten low-fertility countries.

    PubMed

    Eeckhaut, Mieke C W; Sweeney, Megan M

    2016-01-01

    This study investigated the association between contraceptive sterilization and socio-economic status (measured by educational attainment) in ten countries, using data from the 2006-10 National Survey of Family Growth and the 2004-10 Generations and Gender Surveys. The findings confirm that a long-standing association between socio-economic status and sterilization persists in the contemporary United States: female sterilization is associated with economic disadvantage, whereas male sterilization is associated with economic advantage. The latter association is found to be unique to the United States, but female sterilization is associated with disadvantage in most of the other countries studied. While basic demographic background factors such as early childbearing and parity can explain the observed associations in most of the countries, a strong gendered association between sterilization and socio-economic status remains in the United States and Belgium even after adjusting for these factors.

  20. Hiding an elephant: heavy sterile neutrino with large mixing angle does not contradict cosmology

    NASA Astrophysics Data System (ADS)

    Bezrukov, F.; Chudaykin, A.; Gorbunov, D.

    2017-06-01

    We study a model of a keV-scale sterile neutrino with a relatively large mixing with the Standard Model sector. Usual considerations predict active generation of such particles in the early Universe, which leads to constraints from the total Dark Matter density and absence of X-ray signal from sterile neutrino decay. These bounds together may deem any attempt of creation of the keV scale sterile neutrino in the laboratory unfeasible. We argue that for models with a hidden sector coupled to the sterile neutrino these bounds can be evaded, opening new perspectives for the direct studies at neutrino experiments such as Troitsk ν-mass and KATRIN. We estimate the generation of sterile neutrinos in scenarios with the hidden sector dynamics keeping the sterile neutrinos either massless or superheavy in the early Universe. In both cases the generation by oscillations from active neutrinos in plasma is suppressed.

  1. STUDIES ON HOUSEFLIES, STERILIZED WITH X RAYS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sacca, G.

    1961-01-01

    Experiments were conducted on radiosterilization of male houseflies (Musca domestica). The females are monogamous, so that all the females mating with sterile males lay sterile eggs. Tests with 24-kv x rays showed that the most satisfactory method of sterilizing male houseflies consists of irradiating the pupa with 3000 r 2 to 3 days before emergence. The mortality of the irradiated pupae was not appreciably increased and the flies emerging from them were normal in appearance, viability, longevity, and sexual activity. When the irradiated males were mated with normal females, sterility was 100% complete. However, there was a slight tendency formore » females mated with irradiated males to remate with normal males. Sterile males successfully competed with normal males in search of females, and when they were present in overwhelming numbers succeeded in mating with most of the females, leaving them sterile. (H.H.D.)« less

  2. Regret, shame, and denials of women's voluntary sterilization.

    PubMed

    Lalonde, Dianne

    2018-06-01

    Women face extraordinary difficulty in seeking sterilization as physicians routinely deny them the procedure. Physicians defend such denials by citing the possibility of future regret, a well-studied phenomenon in women's sterilization literature. Regret is, however, a problematic emotion upon which to deny reproductive freedom as regret is neither satisfactorily defined and measured, nor is it centered in analogous cases regarding men's decision to undergo sterilization or the decision of women to undergo fertility treatment. Why then is regret such a concern in the voluntary sterilization of women? I argue that regret is centered in women's voluntary sterilization due to pronatalism or expectations that womanhood means motherhood. Women seeking voluntary sterilization are regarded as a deviant identity that rejects what is taken to be their essential role of motherhood and they are thus seen as vulnerable to regret. © 2018 John Wiley & Sons Ltd.

  3. [Patient information prior to sterilization].

    PubMed

    Rasmussen, O V; Henriksen, L O; Baldur, B; Hansen, T

    1992-09-14

    The law in Denmark prescribes that the patient and the general practitioner to whom the patient directs his or her request for sterilization are obliged to confirm by their signatures that the patient has received information about sterilization, its risk and consequences. We asked 97 men and 96 women, if they had received this information prior to their sterilization. They were also asked about their knowledge about sterilization. 54% of the women and 35% of the men indicated that they had not received information. Only few of these wished further information by the hospital doctor. Knowledge about sterilization was good. It is concluded that the information to the patient prior to sterilization is far from optimal. The patients' signature confirming verbal information is not a sufficient safeguard. We recommend, among other things, that the patient should receive written information and that both the general practitioner and the hospital responsible for the operation should ensure that optimal information is received by the patient.

  4. An evaluation of sterilization of endodontic instruments in artificial sponges.

    PubMed

    Vélez, A E; Thomas, D D; del Río, C E

    1998-01-01

    The ability to sterilize endodontic files inserted into synthetic sponges was tested. Sponges were subjected to 5 cycles of either dry heat (Driclave) or steam under pressure (autoclave) sterilization. Sterilization was corroborated by microbiological tests. The sponges and files were pre-sterilized separately using steam under pressure. One hundred eighty files contaminated with Bacillus stearothermophilus spores (experimental and positive control) and 60 noncontaminated files (negative control), were inserted into 60 sponges. After each cycle, each file and a portion of sponge surrounding the file were transferred aseptically to tubes containing trypticase soy broth culture medium for bacteriological analysis. None of the tubes containing files and portions of sponges that were subjected to autoclave grew Bacillus stearothermophilus spores. Two of 60 (3.33%) of the tubes that were subjected to sterilization by Driclave demonstrated bacterial growth. Although the sponges tolerated the dry heat cycles well physically, sterilization was achieved in only 96.67% of the cases.

  5. A sterilization system using ultraviolet photochemical reactions based on nitrous oxide and oxygen gases.

    PubMed

    Ohnishi, Yasutaka; Matsumoto, Hiroyuki; Iwamori, Satoru

    2016-03-01

    Active oxygen species (AOS) generated under ultraviolet (UV) lamps can be applied for various industrial processes owing to extremely strong oxidative abilities. We have already reported on an application of the AOS for a sterilization process of microorganisms. Here, a sterilization method using active oxygen generated under ultraviolet (UV) lamps introducing nitrous oxide (N2O) and oxygen gases into a vacuum chamber was investigated. Nitrogen dioxide (NO2) gas was readily produced from N2O by UV photochemical reactions under the low-pressure mercury lamp and then used to sterilize medical devices. We compared the ability of the N2O gas to sterilize Geobacillus stearothermophilus spores with those of conventional methods. Successful sterilization of spores on various biological indicators was achieved within 60 min, not only in sterilization bags but also in a lumen device. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Development of an Isolator System for PET Drug Compounding with Sterilization and Dispensing Units.

    PubMed

    Waki, Atsuo; Hashimoto, Yuuki; Suzuki, Hisashi; Mizukawa, Yousuke; Kinoshita, Toshiaki; Ichihara, Hironobu; Kaneko, Izumi; Iwakuma, Kazuko; Kawamura, Kazuki; Zhang, Ming-Rong; Fujibayashi, Yasuhisa

    2016-01-01

    To maintain sterility of PET drug is the most important for in-house positron emission tomography (PET) drug manufacturing, and sanitary control of the laboratory to perform aseptic procedure is the key point for the sterility of PET drugs. However, rigorous sanitary control affects both the high cost and the low efficiency. To conquer those, we developed an isolator system especially for PET drug compounding including sterilization and dispensing units. This system consists of a HEPA unit for inlet and outlet, positive regulation of the ear inside isolator, a sterilizer with vapored hydrogen peroxide and a dispenser with self-shield for radiation. We set the materials for the dispenser through gloves, and the compounding such as sterilization and dispensing PET drugs to the containers is performed automatically without radiation. High level assurance of PET drug sterility is expected to be accomplished in the PET centers of the hospitals without high level sanitary control.

  7. 75 FR 21631 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-26

    ... Request; Agreement for Shipment of Devices for Sterilization AGENCY: Food and Drug Administration, HHS.... Agreement for Shipment of Devices for Sterilization--21 CFR 801.150(e) (OMB Control Number 0910-0131... sterile at one establishment and ship the devices in interstate commerce for sterilization at another...

  8. 42 CFR 50.206 - Sterilization of a mentally incompetent individual or of an institutionalized individual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization of a mentally incompetent individual..., DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.206 Sterilization of a mentally incompetent individual or...

  9. 42 CFR 50.203 - Sterilization of a mentally competent individual aged 21 or older.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization of a mentally competent individual... HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.203 Sterilization of a mentally competent individual aged 21 or older...

  10. 49 CFR 1560.105 - Denial of transport or sterile area access; designation for enhanced screening.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Denial of transport or sterile area access... Matching § 1560.105 Denial of transport or sterile area access; designation for enhanced screening. (a...-traveling individuals, including denial of transport or sterile area access or designation for enhanced...

  11. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  12. A reaction-diffusion model of the Darien Gap Sterile Insect Release Method

    NASA Astrophysics Data System (ADS)

    Alford, John G.

    2015-05-01

    The Sterile Insect Release Method (SIRM) is used as a biological control for invasive insect species. SIRM involves introducing large quantities of sterilized male insects into a wild population of invading insects. A fertile/sterile mating produces offspring that are not viable and the wild insect population will eventually be eradicated. A U.S. government program maintains a permanent sterile fly barrier zone in the Darien Gap between Panama and Columbia to control the screwworm fly (Cochliomyia Hominivorax), an insect that feeds off of living tissue in mammals and has devastating effects on livestock. This barrier zone is maintained by regular releases of massive quantities of sterilized male screwworm flies from aircraft. We analyze a reaction-diffusion model of the Darien Gap barrier zone. Simulations of the model equations yield two types of spatially inhomogeneous steady-state solutions representing a sterile fly barrier that does not prevent invasion and a barrier that does prevent invasion. We investigate steady-state solutions using both phase plane methods and monotone iteration methods and describe how barrier width and the sterile fly release rate affects steady-state behavior.

  13. Resolving the evolution of sterile worker castes: a window on the advantages and disadvantages of monogamy

    PubMed Central

    Nonacs, Peter

    2014-01-01

    Many social Hymenoptera species have morphologically sterile worker castes. It is proposed that the evolutionary routes to this obligate sterility must pass through a ‘monogamy window’, because inclusive fitness favours individuals retaining their reproductive totipotency unless they can rear full siblings. Simulated evolution of sterility, however, finds that ‘point of view’ is critically important. Monogamy is facilitating if sterility is expressed altruistically (i.e. workers defer reproduction to queens), but if sterility results from manipulation by mothers or siblings, monogamy may have no effect or lessen the likelihood of sterility. Overall, the model and data from facultatively eusocial bees suggest that eusociality and sterility are more likely to originate through manipulation than by altruism, casting doubt on a mandatory role for monogamy. Simple kin selection paradigms, such as Hamilton's rule, can also fail to account for significant evolutionary dynamics created by factors, such as population structure, group-level effects or non-random mating patterns. The easy remedy is to always validate apparently insightful predictions from Hamiltonian equations with life-history appropriate genetic models. PMID:24647729

  14. Resolving the evolution of sterile worker castes: a window on the advantages and disadvantages of monogamy.

    PubMed

    Nonacs, Peter

    2014-03-01

    Many social Hymenoptera species have morphologically sterile worker castes. It is proposed that the evolutionary routes to this obligate sterility must pass through a 'monogamy window', because inclusive fitness favours individuals retaining their reproductive totipotency unless they can rear full siblings. Simulated evolution of sterility, however, finds that 'point of view' is critically important. Monogamy is facilitating if sterility is expressed altruistically (i.e. workers defer reproduction to queens), but if sterility results from manipulation by mothers or siblings, monogamy may have no effect or lessen the likelihood of sterility. Overall, the model and data from facultatively eusocial bees suggest that eusociality and sterility are more likely to originate through manipulation than by altruism, casting doubt on a mandatory role for monogamy. Simple kin selection paradigms, such as Hamilton's rule, can also fail to account for significant evolutionary dynamics created by factors, such as population structure, group-level effects or non-random mating patterns. The easy remedy is to always validate apparently insightful predictions from Hamiltonian equations with life-history appropriate genetic models.

  15. [Peracetic acid: alternative to the sterilization of bronchofibroscopes].

    PubMed

    Villate, J I; Barrón, J; Zalacaín, R; Urcelay, M I; Hernández, J M; Argumedo, M

    1997-03-01

    The Steris system for cold sterilization with peracetic acid was evaluated by effecting a series of contaminations of a fiberoptic bronchoscope (FB) with specimens of Pseudomonas aeruginosa, Acinetobacter baumanii and Mycobacterium kansasi. The FB was contaminated 24 times, 8 times by each microorganism, using specimens containing more than 10(8) cfu/ml. After fixing the secretions on the FB and washing it with enzyme soap, the BF was sterilized. Specimens were taken for culturing after contamination of the FB, after washing, immediately after sterilization and 1 hour after sterilization. No microorganism growth of any of the samples was detected either immediately after sterilization or one hour later. Microbiological data confirmed contamination of the FB after aspiration and fixation of the inoculate. Chemical and biological tests with B. stearothermophilus spores as specified by the manufacturer were correct in all cases: 24 contaminations and 52 processes of prior training. The efficacy of washing with enzyme soap before sterilization stands out. In 14 of the 24 samples, culture was negative after washing and in 7 the concentration of microorganisms was less than 500 cfu/ml, which confirms the need for appropriate washing before any disinfection or sterilization process is begun. In conclusion, the Steris system based on peracetic acid is an alternative to other systems for cold sterilization or high level disinfection.

  16. Objections to tubal sterilization: what reversibility can and cannot overcome.

    PubMed

    Shain, R N

    1980-09-01

    In a study of 1074 women, 696 and 338 subjects would not seriously consider permanent and hypothetically reversible sterilization, respectively; they were asked to explain their feelings. The reason accounting for most objections to permanent sterilization (65%) was irreversibility and of the subjects who would not consider reversible sterilization or were unsure, 42.7% attributed their principal objection to unnecessary surgery, a factor at least currently intrinsic to the procedure and not readily overcome by education. Many of the remaining objections to both permanent and reversible sterilization may be amenable to change either through education or financial subsidies. In response to a question concerning female attractiveness subsequent to permanent sterilization, 3% of the sample felt attractiveness would decrease and 17.5% were unsure of the surgery's effect. Unsure responses were largely negative in character. This issue is important because of its relationship to intention to undergo sterilization. Upon consideration of reversible sterilization, negative and unsure responses significantly declined, even on the part of those women whose friends have had a poor experience with currently available procedures. Thus, whereas the option of reversibility cannot overcome objections to surgery, it does overcome those regarding permanency; moreover, the "temporary" character it bestows upon surgical sterilization appears to help certain individuals overcome their fears of losing their physical appeal as a result of such procedures.

  17. Sterilization of reusable implant components: a pilot study.

    PubMed

    Cain, J R; Mitchell, D L; Gillespie, J C

    2000-12-01

    The placement and restoration of dental implants require the use of numerous reusable instruments and components. The adequate sterilization of reusable instruments and components is essential to prevent cross contamination between patients. Sterilization usually is accomplished with single-use sterilization envelopes. A reusable sterilization vehicle would reduce costs as well as the waste generated in patient care. This study was designed to determine the efficacy of a 10-cc Pyrex test tube as a sterilization vehicle for reusable dental implant instruments and components. In this study, a reusable dental implant component was placed in a Pyrex test tube, along with a biologic test strip. A control biologic test strip was kept for each test tube. The test tube was closed with a cotton roll folded in half and placed in the opening. Twenty test tubes were prepared. five sets of 4 test tubes were placed in an autoclave in different locations with varying orientations. The autoclave completed a standard sterilization cycle. The biological monitoring service indicated that the biologic test strips in 100% of the test tubes were sterile, whereas the control strips were 100% nonsterile. A Pyrex test tube sealed with a cotton roll can serve as a sterilization vehicle for reusable dental implant instruments and components.

  18. Hybrid male sterility in rice controlled by interaction between divergent alleles of two adjacent genes.

    PubMed

    Long, Yunming; Zhao, Lifeng; Niu, Baixiao; Su, Jing; Wu, Hao; Chen, Yuanling; Zhang, Qunyu; Guo, Jingxin; Zhuang, Chuxiong; Mei, Mantong; Xia, Jixing; Wang, Lan; Wu, Haibin; Liu, Yao-Guang

    2008-12-02

    Sterility is common in hybrids between divergent populations, such as the indica and japonica subspecies of Asian cultivated rice (Oryza sativa). Although multiple loci for plant hybrid sterility have been identified, it remains unknown how alleles of the loci interact at the molecular level. Here we show that a locus for indica-japonica hybrid male sterility, Sa, comprises two adjacent genes, SaM and SaF, encoding a small ubiquitin-like modifier E3 ligase-like protein and an F-box protein, respectively. Most indica cultivars contain a haplotype SaM(+)SaF(+), whereas all japonica cultivars have SaM(-)SaF(-) that diverged by nucleotide variations in wild rice. Male semi-sterility in this heterozygous complex locus is caused by abortion of pollen carrying SaM(-). This allele-specific gamete elimination results from a selective interaction of SaF(+) with SaM(-), a truncated protein, but not with SaM(+) because of the presence of an inhibitory domain, although SaM(+) is required for this male sterility. Lack of any one of the three alleles in recombinant plants does not produce male sterility. We propose a two-gene/three-component interaction model for this hybrid male sterility system. The findings have implications for overcoming male sterility in inter-subspecific hybrid rice breeding.

  19. Hybrid male sterility in rice controlled by interaction between divergent alleles of two adjacent genes

    PubMed Central

    Long, Yunming; Zhao, Lifeng; Niu, Baixiao; Su, Jing; Wu, Hao; Chen, Yuanling; Zhang, Qunyu; Guo, Jingxin; Zhuang, Chuxiong; Mei, Mantong; Xia, Jixing; Wang, Lan; Wu, Haibin; Liu, Yao-Guang

    2008-01-01

    Sterility is common in hybrids between divergent populations, such as the indica and japonica subspecies of Asian cultivated rice (Oryza sativa). Although multiple loci for plant hybrid sterility have been identified, it remains unknown how alleles of the loci interact at the molecular level. Here we show that a locus for indica-japonica hybrid male sterility, Sa, comprises two adjacent genes, SaM and SaF, encoding a small ubiquitin-like modifier E3 ligase-like protein and an F-box protein, respectively. Most indica cultivars contain a haplotype SaM+SaF+, whereas all japonica cultivars have SaM−SaF− that diverged by nucleotide variations in wild rice. Male semi-sterility in this heterozygous complex locus is caused by abortion of pollen carrying SaM−. This allele-specific gamete elimination results from a selective interaction of SaF+ with SaM−, a truncated protein, but not with SaM+ because of the presence of an inhibitory domain, although SaM+ is required for this male sterility. Lack of any one of the three alleles in recombinant plants does not produce male sterility. We propose a two-gene/three-component interaction model for this hybrid male sterility system. The findings have implications for overcoming male sterility in inter-subspecific hybrid rice breeding. PMID:19033192

  20. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice.

    PubMed

    El-Namaky, R; van Oort, P A J

    2017-12-01

    There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two EGMS lines tested here, it was not clear if one or more recessive gene(s) were causing male sterility. This was tested by studying sterility segregation of the F2 populations. Daylength (photoperiod) and minimum temperatures during the period from panicle initiation to flowering had significant effects on male sterility. Results clearly showed that only one recessive gene was involved in causing male sterility. The model was applied to determine the set of sowing dates of two different EGMS lines such that both would flower at the same time the pollen would be completely sterile. In the same time the local popular variety (Sahel 108, the male pollen donor) being sufficiently fertile to produce the hybrid seeds. The model was applied to investigate the viability of the two line breeding system in the same location with climate change (+2oC) and in two other potential locations: in M'Be in Ivory Coast and in the Nile delta in Egypt. Apart from giving new insights in the relation between environment and EGMS, this study shows that these insights can be used to assess safe sowing windows and assess the suitability of sterility and fertility period of different environments for a two line hybrid rice production system.

  1. Female Sterilization and Poor Mental Health: Rates and Relatedness among American Indian and Alaska Native Women.

    PubMed

    Cackler, Christina J J; Shapiro, Valerie B; Lahiff, Maureen

    2016-01-01

    To describe the reproductive and mental health of American Indian and Alaska Native (AI/AN) women, an understudied population. Data from the 2004 Behavioral Risk Factor Surveillance System survey were analyzed to determine the 1) prevalence of female sterilization among a nationally representative sample of reproductive age AI/AN women and 2) the association of female sterilization and poor mental health among AI/AN women compared with non-Hispanic White, non-Hispanic Black, and Hispanic women. Nearly 25% of AI/AN women reported female sterilization, a prevalence higher than the comparison racial/ethnic groups (p < .005). Adjusting for sociodemographic characteristics, AI/AN women reporting female sterilization had nearly 2.5 times the odds of poor mental health compared with AI/AN women not reporting female sterilization (p = .001). The same magnitude of relationship between female sterilization and poor mental health was not found for non-Hispanic White, non-Hispanic Black, and Hispanic women. The prevalence of female sterilization is greater among AI/AN women compared with non-Hispanic White, non-Hispanic Black, and Hispanic women, and AI/AN women reporting female sterilization have higher odds of reporting poor mental health. Common cultural experiences, such as a shared ancestral history of forced sterilizations, may be relevant, and could be considered when providing reproductive and mental health services to AI/AN women. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  2. Risks and Benefits of Salpingectomy at the Time of Sterilization.

    PubMed

    Castellano, Tara; Zerden, Matthew; Marsh, Laura; Boggess, Kim

    2017-11-01

    Bilateral salpingectomy reduces the risk ovarian cancer. The Society of Gynecologic Oncology has recommended surgeons discuss salpingectomy with patients desiring sterilization. This review summarizes current literature on the benefits and risks of bilateral salpingectomy to reduce ovarian cancer risk. Areas of insufficient evidence and directions for further research are discussed. We examined the benefits and risks of bilateral salpingectomy for female surgical sterilization, using a PubMed and EMBASE literature review. Search parameters included articles in English language and keywords "salpingectomy" or "ovarian cancer" combined with "contraception," "sterilization," or "tubal ligation." We reviewed 4 high-quality studies that investigated the increased risk reduction of bilateral salpingectomy compared with traditional sterilization. Overall, evidence shows that salpingectomy moderately decreases the risk of ovarian cancer compared with traditional sterilization. An additional 4 studies, including a meta-analysis, showed salpingectomy likely does not have significant long-term impact on ovarian reserve. Additional benefits include improved contraceptive efficacy and elimination of subsequent ectopic pregnancies. Risks include need for in vitro fertilization for patients experiencing sterilization regret, increases in operative time, and potential increases in surgical risks. Bilateral salpingectomy can reduce ovarian cancer risk compared with traditional sterilization; however, research regarding other outcomes is limited. Challenges to implementation include physician concern regarding surgical risks and patient education. Studies investigating patient-based outcomes are lacking. Bilateral salpingectomy for surgical sterilization is a reasonable option when patients are appropriately informed. Ovarian cancer risk reduction should be one of several factors considered when patients choose a surgical sterilization method.

  3. Seeking sterile neutrinos in Finslerian cosmology

    NASA Astrophysics Data System (ADS)

    Wang, Deng; Meng, Xin-He

    2017-11-01

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H_0 tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N_eff=3.237^{+0.092}_{-0.185}, which is consistent with Δ N_eff > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N_eff=3.143^{+0.064}_{-0.066}, which favors Δ N_eff > 0 at the 1.47σ CL, and m_{ν , sterile}^eff < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration.

  4. Misregulation of Gene Expression and Sterility in Interspecies Hybrids: Causal Links and Alternative Hypotheses.

    PubMed

    Civetta, Alberto

    2016-05-01

    Understanding the origin of species is of interest to biologist in general and evolutionary biologist in particular. Hybrid male sterility (HMS) has been a focus in studies of speciation because sterility imposes a barrier to free gene flow between organisms, thus effectively isolating them as distinct species. In this review, I focus on the role of differential gene expression in HMS and speciation. Microarray and qPCR assays have established associations between misregulation of gene expression and sterility in hybrids between closely related species. These studies originally proposed disrupted expression of spermatogenesis genes as a causative of sterility. Alternatively, rapid genetic divergence of regulatory elements, particularly as they relate to the male sex (fast-male evolution), can drive the misregulation of sperm developmental genes in the absence of sterility. The use of fertile hybrids (both backcross and F1 progeny) as controls has lent support to this alternative explanation. Differences in gene expression between fertile and sterile hybrids can also be influenced by a pattern of faster evolution of the sex chromosome (fast-X evolution) than autosomes. In particular, it would be desirable to establish whether known X-chromosome sterility factors can act as trans-regulatory drivers of genome-wide patterns of misregulation. Genome-wide expression studies coupled with assays of proxies of sterility in F1 and BC progeny have identified candidate HMS genes but functional assays, and a better phenotypic characterization of sterility phenotypes, are needed to rigorously test how these genes might contribute to HMS.

  5. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene

    PubMed Central

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-01-01

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose–methanol–choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed. Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production. PMID:27864513

  6. Reduction in sea lamprey hatching success due to release of sterilized males

    USGS Publications Warehouse

    Bergstedt, Roger A.; McDonald, Rodney B.; Twohey, Michael B.; Mullett, Katherine M.; Young, Robert J.; Heinrich, John W.

    2003-01-01

    Male sea lampreys (Petromyzon marinus), sterilized by injection with bisazir, were released in Lake Superior tributaries from 1991 to 1996 and exclusively in the St. Marys River (the outflow from Lake Superior to Lake Huron) since 1997 as an alternative to chemical control. To determine effectiveness in reducing reproductive potential through the time of hatch, males were observed on nests and egg viability was determined in nests in selected Lake Superior tributaries and the St. Marys River. The proportions of sterilized males observed on nests were not significantly different than their estimated proportion in the population for all streams and years combined or for the St. Marys River alone. It was concluded that sterilized males survive, appear on the spawning grounds, and nest at near their estimated proportion in the population. There was a significant reduction in egg viability corresponding with release of sterilized males for all streams and years combined or for the St. Marys River alone. In the St. Marys River from 1993 to 2000, the percent reduction in egg viability was significantly correlated with the observed proportion of sterile males on nests. It was further concluded that sterilized males remain sterile through nesting and attract and mate with females. Reduction in reproductive potential in the St. Marys River due to both removal of females by traps and sterile-male-release ranged from 34 to 92% from 1993 to 2001 and averaged 64%. From 1999 to 2001, when the program stabilized, reductions ranged from 71 to 92% and averaged 81%. The current release of sterile males in the St. Marys River effectively reduced reproductive potential through the time of hatch and did so near theoretical levels based on numbers released, estimates of population size, and the assumptions of full sterility and competitiveness.

  7. Sterility and Safety Validation for Transport Packaging of Organs and Tissues.

    PubMed

    Cobos, M; Trunzo, L; Vogt, M V; Romero, O; Anessi, C; Pachado, J; Ciávaro, M N; Horak, C; Bacqué, M C

    2018-03-01

    The bags used in the transport of organs and tissues must be sterile, nontoxic, pyrogen free, and must serve as a barrier throughout their useful life. The goal of this study was to show the sterility, safety, and functionality of the bags subjected to irradiation, through validated procedures and techniques. The selected sterilization method was the use of gamma radiation. The sterilization dose was determined based on validated standards for the sterilization of medical products, ISO 11137-2: 2013 and ISO/TS 13004: 2013, using the Verification Dose Maximum method on samples belonging to 3 manufacturing lots. The ISO 10993-5: 2009 standard was used in the cytotoxicity tests, by means of extracts test and quantitative technique of MTT, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide. The tests to determine the expiration date of the kit were performed by ASTM F1980, accelerated aging, and ASTM D3078 to evaluate hermeticity. The irradiation dose validated to reach the required sterility safety level was 22.5 kGy. The constituent materials and the sterilization method do not generated cellular toxicity, and the product was not modified during the simulated time of 5 years. Sterilization by irradiation is a method that leaves no residue, does not harm the properties of the material because it is conducted in cold, and as the sterilizing agent, the energy absorbed by the product is highly penetrating and can be treated in its final packaging, with no risk of postcontamination. It is for this reason that it is prioritized over other methods of sterilization. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene.

    PubMed

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-12-06

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose-methanol-choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production.

  9. Review and state of the art on radiation sterilization of medical devices

    NASA Astrophysics Data System (ADS)

    Dorpema, J. W.

    Review and state of art of radiation sterilization Radiation as a sterilization method was designed in the years 1950-1960. The decade afterwards the application for sterilization of medical products and devices was developped. Extensive studies performed on both the physical, chemical and (micro) biological aspects revealed the requirements for safety and efficacy. These efforts were highly stimulated by the IAEA and resulted in a elegant sterilization method. In product manufacturing, where sterilization represents a final step in the production sequence, radiation has eversince reached its widest application in the field of medical devices. As a spin off it initiated new ideas and approaches towards sterilization in general. Consequently sterility was redefined in terms of a probabilistic concept (10-6) and the bioburden determination method was introduced as a tool for both quality control and potential instrument for dose setting. However these refinements also created controversies, whereby the dose requirements became divided for Europe and North America. Moreover studies recently performed in Europe suggest even a further extension of this opinion gap. Detailed studies, on the clinical effects of low dose treated products (12.5 - 17.5 kGy) are needed to counterbalance the dose suggestions extracted from statistically based dose determinations (> 28 kGy ) and the microbiological resistance determinations ( > 28 - 30 kGy). Dose setting based on risk classification could be considered for distinct product categories. In the mean time a general acceptance of the originally, in the early seventhies, established minimum dose of 25 kGy would seem a reasonable compromise. As the interest for radiation sterilization as the favourable, non polluting and simple method is increasing rapidly over the last five years, both gamma- and beta driven sterilization plants will be needed. Harmonization on sterilization dose therfore requires high priority.

  10. Splint sterilization--a potential registration hazard in computer-assisted surgery.

    PubMed

    Figl, Michael; Weber, Christoph; Assadian, Ojan; Toma, Cyril D; Traxler, Hannes; Seemann, Rudolf; Guevara-Rojas, Godoberto; Pöschl, Wolfgang P; Ewers, Rolf; Schicho, Kurt

    2012-04-01

    Registration of preoperative targeting information for the intraoperative situation is a crucial step in computer-assisted surgical interventions. Point-to-point registration using acrylic splints is among the most frequently used procedures. There are, however, no generally accepted recommendations for sterilization of the splint. An appropriate method for the thermolabile splint would be hydrogen peroxide-based plasma sterilization. This study evaluated the potential deformation of the splint undergoing such sterilization. Deformation was quantified using image-processing methods applied to computed tomographic (CT) volumes before and after sterilization. An acrylic navigation splint was used as the study object. Eight metallic markers placed in the splint were used for registration. Six steel spheres in the mouthpiece were used as targets. Two CT volumes of the splint were acquired before and after 5 sterilization cycles using a hydrogen peroxide sterilizer. Point-to-point registration was applied, and fiducial and target registration errors were computed. Surfaces were extracted from CT scans and Hausdorff distances were derived. Effectiveness of sterilization was determined using Geobacillus stearothermophilus. Fiducial-based registration of CT scans before and after sterilization resulted in a mean fiducial registration error of 0.74 mm; the target registration error in the mouthpiece was 0.15 mm. The Hausdorff distance, describing the maximal deformation of the splint, was 2.51 mm. Ninety percent of point-surface distances were shorter than 0.61 mm, and 95% were shorter than 0.73 mm. No bacterial growth was found after the sterilization process. Hydrogen peroxide-based low-temperature plasma sterilization does not deform the splint, which is the base for correct computer-navigated surgery. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Allelic interaction of F1 pollen sterility loci and abnormal chromosome behaviour caused pollen sterility in intersubspecific autotetraploid rice hybrids.

    PubMed

    He, J H; Shahid, M Q; Li, Y J; Guo, H B; Cheng, X A; Liu, X D; Lu, Y G

    2011-08-01

    The intersubspecific hybrids of autotetraploid rice has many features that increase rice yield, but lower seed set is a major hindrance in its utilization. Pollen sterility is one of the most important factors which cause intersubspecific hybrid sterility. The hybrids with greater variation in seed set were used to study how the F(1) pollen sterile loci (S-a, S-b, and S-c) interact with each other and how abnormal chromosome behaviour and allelic interaction of F(1) sterility loci affect pollen fertility and seed set of intersubspecific autotetraploid rice hybrids. The results showed that interaction between pollen sterility loci have significant effects on the pollen fertility of autotetraploid hybrids, and pollen fertility further decreased with an increase in the allelic interaction of F(1) pollen sterility loci. Abnormal ultra-structure and microtubule distribution patterns during pollen mother cell (PMC) meiosis were found in the hybrids with low pollen fertility in interphase and leptotene, suggesting that the effect-time of pollen sterility loci interaction was very early. There were highly significant differences in the number of quadrivalents and bivalents, and in chromosome configuration among all the hybrids, and quadrivalents decreased with an increase in the seed set of autotetraploid hybrids. Many different kinds of chromosomal abnormalities, such as chromosome straggling, chromosome lagging, asynchrony of chromosome disjunction, and tri-fission were found during the various developmental stages of PMC meiosis. All these abnormalities were significantly higher in sterile hybrids than in fertile hybrids, suggesting that pollen sterility gene interactions tend to increase the chromosomal abnormalities which cause the partial abortion of male gametes and leads to the decline in the seed set of the autotetraploid rice hybrids. © 2011 The Author(s).

  12. [Effects on performance of high-speed dental handpieces subjected to autoclaving].

    PubMed

    Deng, Xiao-hong; Sun, Zheng; Su, Jing; Qiao, Hong; Xiao, Xiao

    2006-07-01

    To investigate the effects on performances of high-speed dental handpieces subjected to autoclaving. The method of trial used to evaluate the effect of autoclaving included that ten chemical and ten biological indicators were arranged in each trial group being set by one sort of temperature and sterilization time. The range of temperature was from 100 degrees C to 134 degrees C and the sterilization time was from 1 to 45 minutes. The reliability of autoclaving was evaluated by the result of chemical indicator and the endospores of Bacillus stearothermophilus subjected to autoclaving. Ten newly imported and ten new domestic dental handpieces in two different brands were used to carry out this trial. The effects produced by autoclaving on performances of dental handpieces subjected to different type autoclaves were evaluated by some parameters. The eligible outcome in killing test of the 221 sterilized dental handpieces proved that the sterilization effect of autoclaving on dental handpieces was reliable. The chemical indicators showed that under the condition of 121 degrees C it needed 20 minutes to reach sterilization standard in the inner package and only 15 minutes on the outer package, and under the condition of 134 degrees C it took 4 minutes to reach sterilization standard in the inner package while only 2 minutes on the outer package. This outcome proved that material with package was more time-consuming than that without package during autoclaving. Autoclaving has positive effects on the performance of dental handpieces, while the autoclave with less-time full sterilization cycle has less effect on it. The performance of dental handpieces sterilized by the autoclave with 6-minute full sterilization cycle might be restorable within certain times of sterilization cycle. The sterilization effect of autoclaving is reliable. In order to reduce the influence on the performance of dental handpieces subjected to autoclaving, it should be reasonable to use the autoclave by which a full sterilization cycle might take less time and no use of package.

  13. Assessing hybrid sterility in Oryza glaberrima x O. sativa hybrid progenies by PCR marker analysis and crossing with wide compatibility varieties.

    PubMed

    Heuer, Sigrid; Miézan, Kouamé M

    2003-09-01

    Interspecific crossing of the African indigenous rice Oryza glaberrima with Oryza sativa cultivars is hindered by crossing barriers causing 100% spikelet sterility in F(1) hybrids. Since hybrids are partially female fertile, fertility can be restored by back crossing (BC) to a recurrent male parent. Distinct genetic models on spikelet sterility have been developed predicting, e.g., the existence of a gamete eliminator and/or a pollen killer. Linkage of sterility to the waxy starch synthase gene and the chromogen gene C, both located on chromosome 6, have been demonstrated. We selected a segregating BC(2)F(3) population of semi-sterile O. glaberrima x O. sativa indica hybrid progenies for analyses with PCR markers located at the respective chromosome-6 region. These analyses revealed that semi-sterile plants were heterozygous for a marker (OSR25) located in the waxy promoter, whereas fertile progenies were homozygous for the O. glaberrima allele. Adjacent markers showed no linkage to spikelet sterility. Semi-sterility of hybrid progenies was maintained at least until the F(4) progeny generation, suggesting the existence of a pollen killer in this plant material. Monitoring of reproductive plant development showed that spikelet sterility was at least partially due to an arrest of pollen development at the microspore stage. In order to address the question whether genes responsible for F(1) sterility in intraspecific hybrids ( O. sativa indica x japonica) also cause spikelet sterility in interspecific hybrids, crossings with wide compatibility varieties (WCV) were performed. WCV accessions possess "neutral" S-loci ( S(n)) improving fertility in intraspecific hybrids. This experiment showed that the tested S(n)-loci had no fertility restoring effect in F(1) interspecific hybrids. Pollen development was completely arrested at the microspore stage and grains were never obtained after selfing. This suggests that distinct or additional S-loci are responsible for sterility of O. glaberrima x O. sativa hybrids.

  14. Comparative transcript profiling of fertile and sterile flower buds from multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis).

    PubMed

    Zhou, Xue; Liu, Zhiyong; Ji, Ruiqin; Feng, Hui

    2017-10-01

    We studied the underlying causes of multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis) by identifying differentially expressed genes (DEGs) related to pollen sterility between fertile and sterile flower buds. In this work, we verified the stages of sterility microscopically and then performed transcriptome analysis of mRNA isolated from fertile and sterile buds using Illumina HiSeq 2000 platform sequencing. Approximately 80% of ~229 million high-quality paired-end reads were uniquely mapped to the reference genome. In sterile buds, 699 genes were significantly up-regulated and 4096 genes were down-regulated. Among the DEGs, 28 pollen cell wall-related genes, 54 transcription factor genes, 45 phytohormone-related genes, 20 anther and pollen-related genes, 212 specifically expressed transcripts, and 417 DEGs located on linkage group A07 were identified. Six transcription factor genes BrAMS, BrMS1, BrbHLH089, BrbHLH091, BrAtMYB103, and BrANAC025 were identified as putative sterility-related genes. The weak auxin signal that is regulated by BrABP1 may be one of the key factors causing pollen sterility observed here. Moreover, several significantly enriched GO terms such as "cell wall organization or biogenesis" (GO:0071554), "intrinsic to membrane" (GO:0031224), "integral to membrane" (GO:0016021), "hydrolase activity, acting on ester bonds" (GO:0016788), and one significantly enriched pathway "starch and sucrose metabolism" (ath00500) were identified in this work. qRT-PCR, PCR, and in situ hybridization experiments validated our RNA-seq transcriptome analysis as accurate and reliable. This study will lay the foundation for elucidating the molecular mechanism(s) that underly sterility and provide valuable information for studying multiple-allele-inherited male sterility in the Chinese cabbage line 'AB01'.

  15. Effects of sterilization on poly(ethylene glycol) hydrogels.

    PubMed

    Kanjickal, Deenu; Lopina, Stephanie; Evancho-Chapman, M Michelle; Schmidt, Steven; Donovan, Duane

    2008-12-01

    The past few decades have witnessed a dramatic increase in the development of polymeric biomaterials. These biomaterials have to undergo a sterilization procedure before implantation. However, many sterilization procedures have been shown to profoundly affect polymer properties. Poly(ethylene glycol) hydrogels have gained increasing importance in the controlled delivery of therapeutics and in tissue engineering. We evaluated the effect of ethylene oxide (EtO), hydrogen peroxide (H(2)O(2)), and gamma sterilization of poly(ethylene glycol) hydrogels on properties relevant to controlled drug delivery and tissue engineering. We observed that the release of cyclosporine (CyA) (an immunosuppressive drug that is effective in combating tissue rejection following organ transplantation) was significantly affected by the type of sterilization. However, that was not the case with rhodamine B, a dye. Hence, the drug release characteristics were observed to be dependent not only on the sterilization procedure but also on the type of agent that needs to be delivered. In addition, differences in the swelling ratios for the sterilized and unsterilized hydrogels were statistically significant for 1:1 crosslinked hydrogels derived from the 8000 MW polymer. Significant differences were also observed for gamma sterilization for 1:1 crosslinked hydrogels derived from the 3350 MW polymer and also the 2:1 crosslinked hydrogels derived from the 8000 MW polymer. Atomic force microscopy (AFM) studies revealed that the roughness parameter for the unsterilized and EtO-sterilized PEG hydrogels remained similar. However, a statistically significant reduction of the roughness parameter was observed for the H(2)O(2) and gamma-sterilized samples. Electron spin resonance (ESR) studies on the unsterilized and the sterilized samples revealed the presence of the peroxy and the triphenyl methyl carbon radical in the samples. The gamma and the H(2)O(2)-sterilized samples were observed to have a much higher concentration of the radical pecies when compared with the EtO and the unsterilized samples. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2008.

  16. Sporicidal efficacy of genipin: a potential theoretical alternative for biomaterial and tissue graft sterilization.

    PubMed

    Reich, Michael S; Akkus, Ozan

    2013-09-01

    Terminal sterilization of musculoskeletal allografts by gamma radiation minimizes the risk of disease transmission but impairs allograft mechanical properties. Commonly employed crosslinking agents can sterilize tissues without affecting mechanical properties adversely; however, these agents are toxic. Genipin is reported to be a benign crosslinking agent that strengthens mechanical properties of tissues; however, the antimicrobial capacity of genipin is largely unknown. The present study's aims were: (1) to assess the sporicidal potential of genipin, (2) to improve antimicrobial capacity by changing chemical and physical treatment conditions. To establish genipin's sterilization potential Bacillus subtilis var. niger spore strips were treated with 0-10% genipin in PBS or in 1:1 DMSO:PBS up to 72 h at room temperature (RT). Sterilizing doses and concentrations of genipin were used to treat B. pumilus and Geobacillus stearothermophilus spores to assess broader spectrum sporicidal activity of genipin. Scanning electron microscopy (SEM) was performed to evaluate gross morphological changes after genipin treatment. Optimal sterilization conditions were determined by evaluating the effects of temperature (RT-50 °C), DMSO:PBS ratio (0:100-100:0), and treatment duration (24-72 h) on B. subtilis. Genipin penetration of full thickness bovine patellar tendon and cortical bone specimens was observed to assess the feasibility of the agent for treating grafts. Initial studies showed that after 72 h of treatment at RT with 0.63-10% genipin/DMSO:PBS B. subtilis spore strips were sterilized; 0.63% genipin/PBS did not sterilize spore strips at 72 h at RT. Genipin doses and concentrations that sterilized B. subtilis spore strips sterilized B. pumilus and G. stearothermophilus spore strips. SEM revealed no gross morphological differences between untreated and treated spores. Treatment optimization resulted in sterilization within 24 h with 100% PBS, and DMSO facilitated sporicidal activity. Genipin penetrated full thickness patellar tendon specimens and 3.72 ± 0.58 mm in cortical bone specimens. Genipin sterilizes B. subtilis, B. pumilus, and G. stearothermophilus spore strips. It penetrates soft and hard tissues at doses previously shown to be non-toxic and to improve mechanical strength in collagen-rich soft tissues. Further studies are indicated to assess genipin's effects on the mechanical properties of genipin-sterilized grafts, the ability of genipin to eradicate infectious species other than spores, and to assess whether sterilant activity persists after penetrating tissues and biomaterials.

  17. Characterizing Effects of Nitric Oxide Sterilization on tert-Butyl Acrylate Shape Memory Polymers

    NASA Astrophysics Data System (ADS)

    Phillippi, Ben

    As research into the potential uses of shape memory polymers (SMPs) as implantable medical devices continues to grow and expand, so does the need for an accurate and reliable sterilization mechanism. The ability of an SMP to precisely undergo a programmed shape change will define its ability to accomplish a therapeutic task. To ensure proper execution of the in vivo shape change, the sterilization process must not negatively affect the shape memory behavior of the material. To address this need, this thesis investigates the effectiveness of a benchtop nitric oxide (NOx) sterilization process and the extent to which the process affects the shape memory behavior of a well-studied tert-Butyl Acrylate (tBA) SMP. Quantifying the effects on shape memory behavior was performed using a two-tiered analysis. A two-tiered study design was used to determine if the sterilization process induced any premature shape recovery and to identify any effects that NOx has on the overall shape memory behavior of the foams. Determining the effectiveness of the NOx system--specially, whether the treated samples are more sterile/less contaminated than untreated--was also performed with a two-tiered analysis. In this case, the two-tiered analysis was employed to have a secondary check for contamination. To elaborate, all of the samples that were deemed not contaminated from the initial test were put through a second sterility test to check for contamination a second time. The results of these tests indicated the NOx system is an effective sterilization mechanism and the current protocol does not negatively impact the shape memory behavior of the tBA SMP. The samples held their compressed shape throughout the entirety of the sterilization process. Additionally, there were no observable impacts on the shape memory behavior induced by NOx. Lastly, the treated samples demonstrated lower contamination than the untreated. This thesis demonstrates the effectiveness of NOx as a laboratory scale sterilization mechanism for heat triggered shape memory polymers. The shape memory analysis indicated that the magnitude of the length changes induced by NOx is small enough that it does not make a statistically significant impact on the shape memory behavior of the foams. Additionally, there were no observable effects on the shape memory behavior induced by NOx. The results further indicated the NOx system is effective at sterilizing porous scaffolds, as none of the sterilized samples showed contamination. Testing methods proved to be effective because the initial sterility test was able to identify all of the contaminated samples and preliminary results indicated that NOx sterilization improves the sterility of the foams.

  18. Portable Chemical Sterilizer for Microbial Decontamination of Surgical Instruments, Fruits and Vegetables, and Field Feeding Equipment

    DTIC Science & Technology

    2006-11-01

    spores of B. stearothermophilus . For all of the test organisms, conditions were found that effected sterilization (6-log kill of contaminating...kill 106 E. coli, L. monocytogenes, S. aureus, and bacterial spores of B. atrophaeus and B. stearothermophilus and to sterilize high-grade...Portable Chemical Sterilizer for Microbial Decontamination of

  19. Portable Chemical Sterilizer (PCS) for Surgical Instruments

    DTIC Science & Technology

    2004-12-01

    PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause

  20. Anoxia-conditioning hormesis alters the relationship between irradiation doses for survival and sterility in the cactus moth, Cactoblastis cactorum (Lepidoptera: Pyralidae)

    USDA-ARS?s Scientific Manuscript database

    One of the most important components of a Sterile Insect Technique (SIT) program is appropriate irradiation dose. Knowing the organismal dose-response enables the selection of a dose that induces the highest level of sterility while preserving the sexual competitiveness and quality of the sterile in...

  1. Intracutaneous sterile water injections do not relieve pain in cervicogenic headache.

    PubMed

    Sand, T; Bovim, G; Helde, G

    1992-11-01

    Intracutaneous sterile water injections have been reported to relieve acute labor pain and cervical pain in whip-lash patients. A double blind cross-over trial has presently been conducted in 10 women with cervicogenic headache in order to investigate whether sterile water injections were effective in this disorder. No benefit was observed for either treatment (isotonic saline or sterile water), neither on pain during the first 14 days nor on neck mobility. We conclude that intracutaneous sterile water injections is not effective in cervicogenic headache.

  2. Sterilization System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  3. The research of using Co-60 γ ray to sterilize different mediums for edible fungus

    NASA Astrophysics Data System (ADS)

    Guozhu, Li; Zhenqian, Guan; Hengshou, Zhao

    1993-10-01

    The present experiment has been carried out by using different dosage of Co—60 γ ray for radiation sterilization of five kinds of cultural materials of edible fungus, The results indicated that sterilization dosage of sawdust is 22 kGy. that of cotton—seed shell and the rest are 26 kGy. We conclude that using Co-60 γ ray to sterilize the cultura 1 materials of edible fungus is a secure and saving labor and energy new method which could sterilize thoroughly.

  4. End-preparation assessments and tests for compounded sterile preparations.

    PubMed

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.

  5. [On the importance of the steam trap to the efficient sterilization of solutions in stored blood bottles by saturated steam under pressure (author's transl)].

    PubMed

    Schreiber, M; Göbel, M

    1979-01-01

    Biological tests with soil samples were performed to fix the sterilization time for a new steam sterilizer. These tests yielded repeatedly positive spore findings despite modifications of the conditions of sterilization. Having excluded a series of possible sources of trouble, the authors stated that the quality of the steam was the assignable cause. After restoration of the functionality of the steam traps, the biological tests yielded negative results also under normal conditions of sterilization.

  6. [Cytological study of radiation induced alterations in cytoplasmic factors controlling male sterility]. Progress report, 1971--1973

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1973-01-01

    Progress is reported on studies of cytoplasmic factors controlling male sterility in plants. Results are reported from cytological comparisons of fertile selections from gamma -irradiated corn with male steriles, mainliners, and restored steriles, in which no consistent differences in cytoplasmic constituents were observed. Results of cytological and genetic studies on mutants of Neurospora crassa, petunia, tobacco, sorghum, sugar beets, Vicia faba, and several gymnosperms are summarized. The relationship between male, sterility of plants and their susceptibility to virus and fungus infections was also studied. (CH)

  7. Federally funded sterilization: time to rethink policy?

    PubMed

    Borrero, Sonya; Zite, Nikki; Creinin, Mitchell D

    2012-10-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women's reproductive choices.

  8. Federally Funded Sterilization: Time to Rethink Policy?

    PubMed Central

    Zite, Nikki; Creinin, Mitchell D.

    2012-01-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women’s reproductive choices. PMID:22897531

  9. Color stability of shade guides after autoclave sterilization.

    PubMed

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  10. Plasma sterilization of Geobacillus Stearothermophilus by O{mathsf2}:N{mathsf2} RF inductively coupled plasma

    NASA Astrophysics Data System (ADS)

    Kylián, O.; Sasaki, T.; Rossi, F.

    2006-05-01

    The aim of this work is to identify the main process responsible for sterilization of Geobacillus Stearothermophilus spores in O{2}:N{2} RF inductively coupled plasma. In order to meet this objective the sterilization efficiencies of discharges in mixtures differing in the initial O{2}/N{2} ratios are compared with plasma properties and with scanning electron microscopy images of treated spores. According to the obtained results it can be concluded that under our experimental conditions the time needed to reach complete sterilization is more related to O atom density than UV radiation intensity, i.e. complete sterilization is not related only to DNA damage as in UV sterilization but more likely to the etching of the spore.

  11. The challenges of heat sterilization of peritoneal dialysis solutions: is there an alternative?

    PubMed

    Hanrahan, Conor T; Himmele, Rainer; Diaz-Buxo, Jose A

    2012-01-01

    Peritoneal dialysis (PD) solutions are currently sterilized in an autoclave using high-temperature saturated steam. Although thermal methods are an effective means of sterilization, the heating of PD solutions results in the formation of toxic glucose degradation products (GDPs). Here, we review basic concepts in the sterilization of PD solutions and discuss possible alternatives to steam sterilization, including filtration, ohmic heat, ionizing radiation, and pulsed ultraviolet light. Although the latter methods have several advantages, many also have prohibitive limitations or have not been adequately studied for use on PD solutions. Thus, in the absence of suitable alternatives, conventional heat sterilization, in combination with low-GDP manufacturing practices, remains the best option at the present time.

  12. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, Charles E.

    1999-02-09

    A method for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process.

  13. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    NASA Astrophysics Data System (ADS)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  14. Effect of Tubal Sterilization Technique on Risk of Serous Ovarian and Primary Peritoneal Carcinoma

    PubMed Central

    LESSARD-ANDERSON, Collette R.; HANDLOGTEN, Kathryn S.; MOLITOR, Rochelle J.; DOWDY, Sean C.; CLIBY, William A.; WEAVER, Amy L.; SAUVER, Jennifer ST.; BAKKUM-GAMEZ, Jamie N.

    2014-01-01

    Objective To determine the effect of excisional tubal sterilization on subsequent development of serous epithelial ovarian cancer (EOC) or primary peritoneal cancer (PPC). Methods We performed a population-based, nested case-control study using the Rochester Epidemiology Project. We identified all patients with a diagnosis of serous EOC or PPC from 1966 through 2009. Each case was age-matched to 2 controls without either diagnosis. Odds ratios (ORs) and corresponding 95% CIs were estimated from conditional logistic regression models. Models were adjusted for prior hysterectomy, prior salpingo-oophorectomy, oral contraceptive use, endometriosis, infertility, gravidity, and parity. Results In total, we identified 194 cases of serous EOC and PPC during the study period and matched them with 388 controls (mean [SD] age, 61.4 [15.2] years). Fourteen cases (7.2%) and 46 controls (11.9%) had undergone tubal sterilization. Adjusted risk of serous EOC or PPC was slightly lower after any tubal sterilization (OR, 0.59 [95% CI, 0.29–1.17]; P=.13). The rate of excisional tubal sterilization was lower in cases than controls (2.6% vs 6.4%). Adjusted risk of serous EOC and PPC was decreased by 64% after excisional tubal sterilization (OR, 0.36 [95% CI, 0.13–1.02]; P=.054) compared with those without sterilization or with nonexcisional tubal sterilization. Conclusions We present a population-based investigation of the effects of excisional tubal sterilization on the risk of serous EOC and PPC. Excisional methods may confer greater risk reduction than other sterilization methods. PMID:25316178

  15. The effect of endoscopic sterilization on reproductive behavior and pair bond maintenance of feral pigeons (Columba livia).

    PubMed

    Heiderich, E; Failing, K; Lierz, M; Schildger, B

    2016-01-01

    Problems related to feral pigeons (Columba livia) in cities mainly result from their large numbers due to uncontrolled population growth. The aim of this study was to evaluate whether endoscopic guided sterilization affects the reproductive behavior of feral pigeons under experimental conditions, with the intention of assessing this technique as a potential method for feral pigeon population control. Five groups of four pairs of feral pigeons each were studied from 8 weeks before, to 7 weeks after sterilization. Both the male and female of the first pair of each group were sterilized, in the second pair only the female and in the third pair only the male was sterilized. The fourth pair acted as a control. All eggs laid were candled to assess fertility. Surgical sterilization had minimal effects on behavior and therefore seems not to have impact on possible field application for population control. All pairs maintained their pair bonds and continued to defend their nesting sites against other pigeons. Only one female copulated with a foreign fertile male while her primary partner was debilitated due to surgery, but returned to him as soon as he recovered. All eggs laid more than 5 days after male sterilization were infertile, whereas all control pairs had fertile eggs. Only one fertile clutch was produced, 5 days after the male's sterilization. Therefore it is assumed that males remain fertile for a limited period of time. Endoscopic sterilization seems to be a promising method for field control of feral pigeon populations and sterilization of the male only seems sufficient.

  16. A novel approach identifying hybrid sterility QTL on the autosomes of Drosophila simulans and D. mauritiana.

    PubMed

    Dickman, Christopher T D; Moehring, Amanda J

    2013-01-01

    When species interbreed, the hybrid offspring that are produced are often sterile. If only one hybrid sex is sterile, it is almost always the heterogametic (XY or ZW) sex. Taking this trend into account, the predominant model used to explain the genetic basis of F1 sterility involves a deleterious interaction between recessive sex-linked loci from one species and dominant autosomal loci from the other species. This model is difficult to evaluate, however, as only a handful of loci influencing interspecies hybrid sterility have been identified, and their autosomal genetic interactors have remained elusive. One hindrance to their identification has been the overwhelming effect of the sex chromosome in mapping studies, which could 'mask' the ability to accurately map autosomal factors. Here, we use a novel approach employing attached-X chromosomes to create reciprocal backcross interspecies hybrid males that have a non-recombinant sex chromosome and recombinant autosomes. The heritable variation in phenotype is thus solely caused by differences in the autosomes, thereby allowing us to accurately identify the number and location of autosomal sterility loci. In one direction of backcross, all males were sterile, indicating that sterility could be entirely induced by the sex chromosome complement in these males. In the other direction, we identified nine quantitative trait loci that account for a surprisingly large amount (56%) of the autosome-induced phenotypic variance in sterility, with a large contribution of autosome-autosome epistatic interactions. These loci are capable of acting dominantly, and thus could contribute to F1 hybrid sterility.

  17. Cytoplasmic male sterility contributes to hybrid incompatibility between subspecies of Arabidopsis lyrata.

    PubMed

    Aalto, Esa A; Koelewijn, Hans-Peter; Savolainen, Outi

    2013-10-03

    In crosses between evolutionarily diverged populations, genomic incompatibilities may result in sterile hybrids, indicating evolution of reproductive isolation. In several plant families, crosses within a population can also lead to male sterile progeny because of conflict between the maternally and biparentally inherited genomes. We examined hybrid fertility between subspecies of the perennial outcrossing self-incompatible Lyrate rockcress (Arabidopsis lyrata) in large reciprocal F2 progenies and three generations of backcrosses. In one of the reciprocal F2 progenies, almost one-fourth of the plants were male-sterile. Correspondingly, almost one-half of the plants in one of the four reciprocal backcross progenies expressed male sterility. In an additional four independent F2 and backcross families, three segregated male sterility. The observed asymmetrical hybrid incompatibility is attributable to male sterility factors in one cytoplasm, for which the other population lacks effective fertility restorers. Genotyping of 96 molecular markers and quantitative trait locus mapping revealed that only 60% of the plants having the male sterile cytoplasm and lacking the corresponding restorers were phenotypically male-sterile. Genotyping data showed that there is only one restorer locus, which mapped to a 600-kb interval at the top of chromosome 2 in a region containing a cluster of pentatricopeptide repeat genes. Male fertility showed no trade-off with seed production. We discuss the role of cytoplasm and genomic conflict in incipient speciation and conclude that cytoplasmic male sterility-lowering hybrid fitness is a transient effect with limited potential to form permanent reproductive barriers between diverged populations of hermaphrodite self-incompatible species.

  18. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene.

    PubMed

    Muratoglu, Orhun K; Merrill, Edward W; Bragdon, Charles R; O'Connor, Daniel; Hoeffel, Daniel; Burroughs, Brian; Jasty, Murali; Harris, William H

    2003-12-01

    Radiation cross-linking increases the wear resistance of polyethylene used in total hip replacement. Radiation also generates residual free radicals, which are detrimental to long-term properties of polyethylene. Two approaches are used to stabilize the residual free radicals and terminally sterilize the components. One is postirradiation annealing with gas sterilization and the other is postirradiation melting with gamma sterilization in nitrogen. The hypothesis of the current study is that postirradiation annealing followed by gamma sterilization in nitrogen will result in more free radicals in polyethylene than gamma sterilization either in air or in nitrogen alone. To test this hypothesis, concentration of residual free radicals was quantified in polyethylene that was annealed and gamma sterilized in nitrogen and control polyethylenes gamma sterilized in air versus in nitrogen. Three crosslinked polyethylenes that were melted and gas sterilized also were included in the study. The effects of residual free radicals were studied by accelerated aging. Oxidation levels and weight loss in bidirectional pin-on-disk tests were determined before and after aging. Polyethylene that was subjected to postirradiation annealing and gamma sterilization resulted in 58% more residual free radicals than control polyethylenes. Weight loss of the annealed polyethylene increased by 16-fold on accelerated aging and had three times higher oxidation levels than that measured in control polyethylenes after aging. In contrast, polyethylenes that were stabilized with postirradiation melting and terminally gas sterilized showed no detectable residual free radicals. Accelerated aging did not affect the weight loss and oxidation levels of melted polyethylenes.

  19. The influence of sterilization on nitrogen-included ultrananocrystalline diamond for biomedical applications.

    PubMed

    Tong, Wei; Tran, Phong A; Turnley, Ann M; Aramesh, Morteza; Prawer, Steven; Brandt, Milan; Fox, Kate

    2016-04-01

    Diamond has shown great potential in different biomedical applications, but the effects of sterilization on its properties have not been investigated. Here, we studied the influence of five sterilization techniques (solvent cleaning, oxygen plasma, UV irradiation, autoclave and hydrogen peroxide) on nitrogen-included ultrananocrystalline diamond. The chemical modification of the diamond surface was evaluated using X-ray photoelectron spectroscopy and water contact angle measurements. Different degrees of surface oxidation and selective sp(2) bonded carbon etching were found following all sterilization techniques, resulting in an increase of hydrophilicity. Higher viabilities of in vitro mouse 3T3 fibroblasts and rat cortical neuron cells were observed on oxygen plasma, autoclave and hydrogen peroxide sterilized diamond, which correlated with their higher hydrophilicity. By examination of apatite formation in simulated body fluid, in vivo bioactivity was predicted to be best on those surfaces which have been oxygen plasma treated and lowest on those which have been exposed to UV irradiation. The charge injection properties were also altered by the sterilization process and there appears to be a correlation between these changes and the degree of oxygen termination of the surface. We find that the modification brought by autoclave, oxygen plasma and hydrogen peroxide were most consistent with the use of N-UNCD in biological applications as compared to samples sterilized by solvent cleaning or UV exposure or indeed non-sterilized. A two-step process of sterilization by hydrogen peroxide following oxygen plasma treatment was then suggested. However, the final choice of sterilization technique will depend on the intended end application. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Ethylene oxide sterilization: how hospitals can adapt to the changes.

    PubMed

    1994-12-01

    Ethylene oxide (EtO) gas sterilizers have been used by hospitals for over 40 years to sterilize surgical equipment and supplies that are heat sensitive or that cannot tolerate excessive moisture. However, in recent decades, EtO has been recognized as a potential mutagenic, reproductive, neurologic, and fire and explosion hazard to workers, and one agency has reportedly voted to classify EtO as carcinogenic to humans. Strict regulations concerning EtO exposure have been imposed by the Occupational Safety and Health Administration (OSHA), and the use of EtO, along with other toxic pollutants, is also being monitored by the Environmental Protection Agency (EPA) under the Clean Air Act. In addition, the use of chlorofluorocarbons (CFCs) as EtO diluents has focused attention on the EtO-CFC mixtures used in many sterilizers because CFCs have been linked to destruction of the ozone layer. Concerns about restrictive regulations related to these issues have prompted many hospitals to examine their use of EtO sterilization and propagated the misinformation that EtO sterilization is being phased out. In this article, we address some commonly asked questions regarding the use and regulation of EtO mixtures, as well as alternative sterilization agents and methods; provide two case studies illustrating how hospitals can evaluate various sterilization options; and summarize our conclusions and recommendations for hospitals facing decisions about sterilization techniques. For related topics, also see our Evaluation Update on endoscope reprocessors and our Hazard Report on improperly connected EtO-CFC cylinders to EtO sterilizers in this issue.

  1. Case study on the orientation of phaco hand pieces during steam sterilization processes.

    PubMed

    van Doornmalen Gomez Hoyos, J P C M; van Wezel, R A C; van Doornmalen, H W J M

    2015-05-01

    Steam sterilization is an essential part of infection prevention. The literature shows that sterilization of medical instruments containing channels is not trivial. Phaco hand pieces have a simple configuration: a device contains a channel with a constant radius. No literature was found indicating whether the sterilization conditions on the inner surface of a phaco hand piece are influenced by the orientation of the hand piece. To determine whether the orientation of a phaco hand piece influences the results of a sterilization process of this device. A qualitative case study, including experiments, is performed with a protocolled combination of steam sterilizer, process, phaco hand piece, orientation of the phaco hand piece, and wrapping. In this specific case, the orientation of the hand piece influenced the result of the steam sterilization process; in vertically (upright) oriented phaco hand pieces with free water drainage, sterilization conditions are reproducibly established. In the same process, in horizontally oriented or vertically oriented hand pieces without free drainage, these conditions are not established in a reproducible way. In the investigated combination of sterilizer, process, load, loading pattern and wrapping, phaco hand pieces have to be oriented vertically (upright) with free water drainage to obtain steam sterilization conditions on the inner surface. It is likely that instruments with comparable configuration and dimensions will yield comparable results. It is therefore recommended that this issue is considered during the development of medical instruments and during performance qualifications of such instruments. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Mini-implants for Orthodontic Anchorage: Surface Analysis after Redrilling and Sterilization - An in vitro Study.

    PubMed

    Gross, J M; Nascimento, G G; Araújo, V C; Bönecker, Mjs; Furuse, C

    2016-04-01

    This study aimed to investigate, in vitro, possible alterations on mini-implants surface after retrieval and if the cleaning process and sterilization can predispose damages. Two commercial mini-implants were tested for deformations after drilling and removing in artificial bone four times. Samples were analyzed by scanning electron microscopy, and surface alterations verified through thread and pitches deformation. To alterations caused by insertion/removal and the cleaning process and sterilization were verified in different procedures: Insertions and sterilization, only insertions, and only sterilization. Photomicrographs were analyzed in order to compare the surface characteristics. Head deformation was verified qualitatively. For a quantitative analysis, distances between threads were measured across the active part of the mini-implants. No deformation was observed in both groups. The cleaning and sterilization processes did not provoke alteration in both groups. Nevertheless, the presence of synthetic bone was noted in some samples. The mean distances between implant threads were similar after all steps in all regions in both groups. The results suggest that the tested mini-implants can be retrieved without damage of its surface after four cycles of insertion, removal, and sterilization. Orthodontic mini-implant, Redrilling, Sterilization. Mini-implants can be retrieved without damage to its surface after four cycles of insertion, removal, and sterilization in the same patient without representing a biological concern.

  3. Will ethylene oxide sterilization influence the application of novel Cu/LDPE nanocomposite intrauterine devices?

    PubMed

    Xia, Xianping; Wang, Yun; Cai, Shuizhou; Xie, Changsheng; Zhu, Changhong

    2009-01-01

    Copper/low-density polyethylene (Cu/LDPE) nanocomposite intrauterine device (IUD) is an implanted medicinal device that must be sterilized before use. Sterilization processes act either chemically or physically, leading to a lethal change in the structure or function of organic macromolecules in microorganisms. Given the nature of their action, sterilization might also attack the macromolecules of polymers by the same mechanisms, resulting in changes in surface functional groups and in the internal structure of the polymer. If sterilization leads to changes in surface functional groups and in the internal structure of the LDPE matrix, which will influence the mechanical property and cupric ions release rate of novel Cu/LDPE nanocomposite IUDs, potential clinical application will be limited. Therefore, it is necessary to study the influence of ethylene oxide sterilization on the potential clinical application of novel Cu/LDPE nanocomposite IUDs. The influence of ethylene oxide sterilization on the internal structure, surface functional groups, mechanical property and cupric ions release rate of novel Cu/LDPE nanocomposite IUDs was studied using differential scanning calorimetry, attenuated total reflection Fourier transform infrared spectroscopy, tensile testing and absorbance measurement. Ethylene oxide sterilization did not have any influence on the internal structure, surface functional groups, mechanical property and cupric ions release rate of novel Cu/LDPE nanocomposite intrauterine devices. Ethylene oxide sterilization will not affect the potential application of novel Cu/LDPE nanocomposite IUDs.

  4. The Sterilization Effect of Cooperative Treatment of High Voltage Electrostatic Field and Variable Frequency Pulsed Electromagnetic Field on Heterotrophic Bacteria in Circulating Cooling Water

    NASA Astrophysics Data System (ADS)

    Gao, Xuetong; Liu, Zhian; Zhao, Judong

    2018-01-01

    Compared to other treatment of industrial circulating cooling water in the field of industrial water treatment, high-voltage electrostatic field and variable frequency pulsed electromagnetic field co-sterilization technology, an advanced technology, is widely used because of its special characteristics--low energy consumption, nonpoisonous and environmentally friendly. In order to get a better cooling water sterilization effect under the premise of not polluting the environment, some experiments about sterilization of heterotrophic bacteria in industrial circulating cooling water by cooperative treatment of high voltage electrostatic field and variable frequency pulsed electromagnetic field were carried out. The comparison experiment on the sterilization effect of high-voltage electrostatic field and variable frequency pulsed electromagnetic field co-sterilization on heterotrophic bacteria in industrial circulating cooling water was carried out by change electric field strength and pulse frequency. The results show that the bactericidal rate is selective to the frequency and output voltage, and the heterotrophic bacterium can only kill under the condition of sweep frequency range and output voltage. When the voltage of the high voltage power supply is 4000V, the pulse frequency is 1000Hz and the water temperature is 30°C, the sterilization rate is 48.7%, the sterilization rate is over 90%. Results of this study have important guiding significance for future application of magnetic field sterilization.

  5. Effects of gamma-sterilization on the physico-chemical properties of natural sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, Tracy L.; Kukkadapu, Ravi K.; Madden, Andrew S.

    2008-06-30

    A series of experiments were completed to determine the effects of soil sterilization on various soil chemical properties including U(VI) sorption, soil pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state. Soils under investigation were a saprolitic sequence of interbedded weathered shale and limestone collected from the Oak Ridge Reservation (ORR). Sediments were sterilized by either steam sterilization at 121oC or by γ-irradiation using a cobalt-60 source. Subsamples of sediments were pretreated with dithionate-citrate-bicarbonate (DCB) and/or H2O2 to remove reducible Fe(III) oxides and NOM. Results from aerobic U(VI) sorption experiments indicated that γ-sterilized sediments sorbed moremore » U(VI) compared to non-sterile sediments. Results from sorption experiments completed using DCB and H2O2-treated samples indicated that the iron oxide and NOM fractions of the sediment accounted for the majority of U(VI) sorption and that γ-irradiation of these phases resulted in increased sorption of U(VI). Mössbauer spectra of γ-sterilized sedimentsdisplayed a decrease in the amount of ferric iron associated with goethite and a small increase in the amount of reduced iron in silicate minerals compared to spectra from non-sterile samples. Our results suggest that sterilization by γ-irradiation induced iron reduction that may have increased sorption of U(VI) on these sediments.« less

  6. A Simple Genetic Incompatibility Causes Hybrid Male Sterility in Mimulus

    PubMed Central

    Sweigart, Andrea L.; Fishman, Lila; Willis, John H.

    2006-01-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1–hms2 incompatibility. PMID:16415357

  7. A simple genetic incompatibility causes hybrid male sterility in mimulus.

    PubMed

    Sweigart, Andrea L; Fishman, Lila; Willis, John H

    2006-04-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1-hms2 incompatibility.

  8. Sterilization of microorganisms by the supercritical carbon dioxide micro-bubble method.

    PubMed

    Ishikawa, H; Shimoda, M; Shiratsuchi, H; Osajima, Y

    1995-10-01

    Lactobacillus brevis and Saccharomyces cerevisiae were completely sterilized by the supercritical (SC) CO2 micro-bubble method. Gaseous (G) and liquid (LQ) CO2 were used in a similar manner to compare the sterilizing effect. Among the three treatments, the microorganisms were only effectively sterilized by the SC CO2 treatment at 25 MPa and 35 degrees C.

  9. Registration of BTx623ms8 - a new and easily identifiable nuclear male sterile mutant in sorghum

    USDA-ARS?s Scientific Manuscript database

    The USDA-ARS has released a new nuclear male sterile sorghum mutant BTx623ms8 (Registration No.xxxx, PIxxxxx). Previously, seven nuclear male sterile mutants have been reported but three are no longer available for sorghum. Here we register a new nuclear male sterile mutant from a mutagenized BTx62...

  10. "We never thought of a vasectomy": a qualitative study of men and women's counseling around sterilization.

    PubMed

    Shih, Grace; Dubé, Kate; Dehlendorf, Christine

    2013-09-01

    Sterilization is the most commonly used method of contraception in the United States; however, little is known about how providers counsel about these procedures or the information patients desire. In this study, we explore male and female experiences of sterilization counseling and their perspectives on ideal sterilization counseling. In-depth individual and group interviews were conducted with 37 heterosexual couples between the ages of 25 and 55 years. Each couple had reached their desired family size. Interviews were recorded and transcribed using NVivo software and analyzed using modified grounded theory. Men and women differed in their experiences of sterilization counseling. Women commonly received counseling on female sterilization but not vasectomy, while men rarely discussed either form of sterilization with their providers. Both men and women desired more information about sterilization. Contraceptive counseling of couples who have completed childbearing does not routinely include men or the option of vasectomy, despite the advantages of this method with respect to safety, efficacy and cost. Family planning and primary care providers have an important role in ensuring that couples are aware of all their options and can make an informed decision about their contraception. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Development of a sterilizing in-place application for a production machine using Vaporized Hydrogen Peroxide.

    PubMed

    Mau, T; Hartmann, V; Burmeister, J; Langguth, P; Häusler, H

    2004-01-01

    The use of steam in sterilization processes is limited by the implementation of heat-sensitive components inside the machines to be sterilized. Alternative low-temperature sterilization methods need to be found and their suitability evaluated. Vaporized Hydrogen Peroxide (VHP) technology was adapted for a production machine consisting of highly sensitive pressure sensors and thermo-labile air tube systems. This new kind of "cold" surface sterilization, known from the Barrier Isolator Technology, is based on the controlled release of hydrogen peroxide vapour into sealed enclosures. A mobile VHP generator was used to generate the hydrogen peroxide vapour. The unit was combined with the air conduction system of the production machine. Terminal vacuum pumps were installed to distribute the gas within the production machine and for its elimination. In order to control the sterilization process, different physical process monitors were incorporated. The validation of the process was based on biological indicators (Geobacillus stearothermophilus). The Limited Spearman Karber Method (LSKM) was used to statistically evaluate the sterilization process. The results show that it is possible to sterilize surfaces in a complex tube system with the use of gaseous hydrogen peroxide. A total microbial reduction of 6 log units was reached.

  12. Semiochemical mediated enhancement of males to complement sterile insect technique in management of the tephritid pest Bactrocera tryoni (Froggatt).

    PubMed

    Khan, Mohammed Abul Monjur; Manoukis, Nicholas C; Osborne, Terry; Barchia, Idris M; Gurr, Geoff M; Reynolds, Olivia L

    2017-10-17

    Queensland fruit fly, Bactrocera tryoni (Froggatt), is the most significant pest of Australia's $9 billion horticulture industry. The sterile insect technique (SIT) and cue-lure (a synthetic analogue of raspberry ketone (RK))-based male annihilation technique (MAT) are two of the most effective management tools against this pest. However, combining these two approaches is considered incompatible as MAT kills sterile and 'wild' males indiscriminately. In the present study we tested the effect of pre-release feeding of B. tryoni on RK on their post-release survival and response to MAT in field cages and in a commercial orchard. In both settings, survival was higher for RK supplemented adults compared to control (i.e. RK denied) adults. A lower number of RK supplemented sterile males were recaptured in MAT baited traps in both the field cages and orchard trials compared to RK denied sterile males. The advantage of this novel "male replacement" approach (relatively selective mortality of wild males at lure-baited traps while simultaneously releasing sterile males) is increasing the ratio of sterile to wild males in the field population, with potential for reducing the number of sterile males to be released.

  13. Combination of reversible male sterility and doubled haploid production by targeted inactivation of cytoplasmic glutamine synthetase in developing anthers and pollen.

    PubMed

    Ribarits, Alexandra; Mamun, A N K; Li, Shipeng; Resch, Tatiana; Fiers, Martijn; Heberle-Bors, Erwin; Liu, Chun-Ming; Touraev, Alisher

    2007-07-01

    Reversible male sterility and doubled haploid plant production are two valuable technologies in F(1)-hybrid breeding. F(1)-hybrids combine uniformity with high yield and improved agronomic traits, and provide self-acting intellectual property protection. We have developed an F(1)-hybrid seed technology based on the metabolic engineering of glutamine in developing tobacco anthers and pollen. Cytosolic glutamine synthetase (GS1) was inactivated in tobacco by introducing mutated tobacco GS genes fused to the tapetum-specific TA29 and microspore-specific NTM19 promoters. Pollen in primary transformants aborted close to the first pollen mitosis, resulting in male sterility. A non-segregating population of homozygous doubled haploid male-sterile plants was generated through microspore embryogenesis. Fertility restoration was achieved by spraying plants with glutamine, or by pollination with pollen matured in vitro in glutamine-containing medium. The combination of reversible male sterility with doubled haploid production results in an innovative environmentally friendly breeding technology. Tapetum-mediated sporophytic male sterility is of use in foliage crops, whereas microspore-specific gametophytic male sterility can be applied to any field crop. Both types of sterility preclude the release of transgenic pollen into the environment.

  14. Ozone Gas as a Benign Sterilization Treatment for PLGA Nanofiber Scaffolds

    PubMed Central

    de Jesus Andreoli Pinto, Terezinha; Bou-Chacra, Nadia Araci; Galante, Raquel; de Araújo, Gabriel Lima Barros; do Nascimento Pedrosa, Tatiana; Maria-Engler, Silvya Stuchi

    2016-01-01

    The use of electrospun nanofibers for tissue engineering and regenerative medicine applications is a growing trend as they provide improved support for cell proliferation and survival due, in part, to their morphology mimicking that of the extracellular matrix. Sterilization is a critical step in the fabrication process of implantable biomaterial scaffolds for clinical use, but many of the existing methods used to date can negatively affect scaffold properties and performance. Poly(lactic-co-glycolic acid) (PLGA) has been widely used as a biodegradable polymer for 3D scaffolds and can be significantly affected by current sterilization techniques. The aim of this study was to investigate pulsed ozone gas as an alternative method for sterilizing PLGA nanofibers. The morphology, mechanical properties, physicochemical properties, and response of cells to PLGA nanofiber scaffolds were assessed following different degrees of ozone gas sterilization. This treatment killed Geobacillus stearothermophilus spores, the most common biological indicator used for validation of sterilization processes. In addition, the method preserved all of the characteristics of nonsterilized PLGA nanofibers at all degrees of sterilization tested. These findings suggest that ozone gas can be applied as an alternative method for sterilizing electrospun PLGA nanofiber scaffolds without detrimental effects. PMID:26757850

  15. Ozone Gas as a Benign Sterilization Treatment for PLGA Nanofiber Scaffolds.

    PubMed

    Rediguieri, Carolina Fracalossi; Pinto, Terezinha de Jesus Andreoli; Bou-Chacra, Nadia Araci; Galante, Raquel; de Araújo, Gabriel Lima Barros; Pedrosa, Tatiana do Nascimento; Maria-Engler, Silvya Stuchi; De Bank, Paul A

    2016-04-01

    The use of electrospun nanofibers for tissue engineering and regenerative medicine applications is a growing trend as they provide improved support for cell proliferation and survival due, in part, to their morphology mimicking that of the extracellular matrix. Sterilization is a critical step in the fabrication process of implantable biomaterial scaffolds for clinical use, but many of the existing methods used to date can negatively affect scaffold properties and performance. Poly(lactic-co-glycolic acid) (PLGA) has been widely used as a biodegradable polymer for 3D scaffolds and can be significantly affected by current sterilization techniques. The aim of this study was to investigate pulsed ozone gas as an alternative method for sterilizing PLGA nanofibers. The morphology, mechanical properties, physicochemical properties, and response of cells to PLGA nanofiber scaffolds were assessed following different degrees of ozone gas sterilization. This treatment killed Geobacillus stearothermophilus spores, the most common biological indicator used for validation of sterilization processes. In addition, the method preserved all of the characteristics of nonsterilized PLGA nanofibers at all degrees of sterilization tested. These findings suggest that ozone gas can be applied as an alternative method for sterilizing electrospun PLGA nanofiber scaffolds without detrimental effects.

  16. The Genetics of Hybrid Male Sterility Between the Allopatric Species Pair Drosophila persimilis and D. pseudoobscura bogotana: Dominant Sterility Alleles in Collinear Autosomal Regions

    PubMed Central

    Chang, Audrey S.; Noor, Mohamed A. F.

    2007-01-01

    F1 hybrid male sterility is thought to result from interactions between loci on the X chromosome and dominant-acting loci on the autosomes. While X-linked loci that contribute to hybrid male sterility have been precisely localized in many animal taxa, their dominant autosomal interactors have been more difficult to localize precisely and/or have been shown to be of relatively smaller effect. Here, we identified and mapped at least four dominant autosomal factors contributing to hybrid male sterility in the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana. Using these results, we tested predictions of reduced recombination models of speciation. Consistent with these models, three of the four QTL associated with hybrid male sterility occur in collinear (uninverted) regions of these genomes. Furthermore, these QTL do not contribute significantly to hybrid male sterility in crosses between the sympatric species D. persimilis and D. pseudoobscura pseudoobscura. The autosomal loci identified in this study provide the basis for introgression mapping and, ultimately, for molecular cloning of interacting genes that contribute to F1 hybrid sterility. PMID:17277364

  17. The genetics of hybrid male sterility between the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana: dominant sterility alleles in collinear autosomal regions.

    PubMed

    Chang, Audrey S; Noor, Mohamed A F

    2007-05-01

    F(1) hybrid male sterility is thought to result from interactions between loci on the X chromosome and dominant-acting loci on the autosomes. While X-linked loci that contribute to hybrid male sterility have been precisely localized in many animal taxa, their dominant autosomal interactors have been more difficult to localize precisely and/or have been shown to be of relatively smaller effect. Here, we identified and mapped at least four dominant autosomal factors contributing to hybrid male sterility in the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana. Using these results, we tested predictions of reduced recombination models of speciation. Consistent with these models, three of the four QTL associated with hybrid male sterility occur in collinear (uninverted) regions of these genomes. Furthermore, these QTL do not contribute significantly to hybrid male sterility in crosses between the sympatric species D. persimilis and D. pseudoobscura pseudoobscura. The autosomal loci identified in this study provide the basis for introgression mapping and, ultimately, for molecular cloning of interacting genes that contribute to F(1) hybrid sterility.

  18. The promotion of family planning by financial payments: the case of Bangladesh.

    PubMed

    Cleland, J; Mauldin, W P

    1991-01-01

    The government of Bangladesh and the World Bank commissioned a Compensation Payments Study, carried out in 1987, to assess the merits and demerits of payments for sterilizations to clients, medical personnel, and intermediaries who motivate and refer clients. The study conclusively shows that the decision of Bangladeshi men and women to undergo sterilization is a considered and voluntary act, taken in knowledge of the nature and implications of the procedure, and in knowledge of alternative methods of regulating fertility. There is a high degree of client satisfaction among those who have been sterilized, although among clients who had fewer than three children, 25 percent expressed regret that they had been sterilized. Money may be a contributing factor to the decision to become sterilized in a large majority of cases, but a dominant motive for only a very small minority. Payments to referrers have fostered a large number of unofficial, self-employed agents--particularly men who recruit vasectomy cases. These agents provide information about the procedures for being sterilized, particularly to the poor. They also concentrate on sterilizations to the exclusion of other methods, and are prone to minimize the disadvantages and exaggerate the attractions of sterilization.

  19. Cytological study of radiation induced alterations in cytoplasmic factors controlling male sterility in corn. Progress report, February 28, 1973--December 1, 1973

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwardson, J.R.

    1973-01-01

    Cytoplasmic male sterile accessions, other than T-type, are being backcrossed to adapted maintainer and restorer inbred corn lines. Fertile selections from gamma -irradiated T-type corn continue to exhibit resistance to infection by race-T of Helminthosporium maydis in field and greenhouse tests. Cytological comparisons of these fertile selections and T-sterile, maintainer, and restorer lines are continuing. Dominant male sterility and its suppression in S-cytoplasm corn is being investigated. lnduction of cytoplasmic male sterility in normal cytoplasm corn and suppression of susceptibility to Helminthosporium maydis infection in T cytoplasm corn is being attempted with chemical mutagens. Consistent differences in cytoplasmic inclusions inmore » sterile and maintainer Vicia faba were observed. Consistent differences in mitochondria were observed in cytological comparisons of normal and sterile corn. These abnormal mitochondria and non-Mendelian plastid abnormalities in corn, sorghum, tobacco, and petunia will be used in studying the fertilization process. Investigations of the properties of Datura Q-virus are near completion. Cytological and serological studies indicate the Q-virus is a strain of tobacco streak virus. Graft-transmission of cytoplasmic male sterility is being attempted in sunflower. (auth)« less

  20. Influences of the steam sterilization on the properties of calcium phosphate porous bioceramics.

    PubMed

    Li, Xiangfeng; Guo, Bo; Xiao, Yumei; Yuan, Tun; Fan, Yujiang; Zhang, Xingdong

    2016-01-01

    The influences of steam sterilization on the physicochemical properties of calcium phosphate (Ca-P) porous bioceramics, including β-tricalcium phosphate (β-TCP), biphasic calcium phosphate (BCP) and hydroxyapatite (HA) are investigated. After being steam sterilized in an autoclave (121 °C for 40 min), the porous bioceramics are dried and characterized. The steam sterilization has no obvious effects on the phase composition, thermal stability, pH value and dissolubility of β-TCP porous bioceramic, but changes its morphology and mechanical strength. Meanwhile, the steam sterilization leads to the significant changes of the morphology, phase composition, pH value and dissolubility of BCP porous bioceramic. The increase of dissolubility and mechanical strength, the decrease of pH value of the immersed solution and partial oriented growth of crystals are also observed in HA porous bioceramic after steam sterilization. These results indicate that the steam sterilization can result in different influences on the physicochemical properties of β-TCP, BCP and HA porous bioceramics, thus the application of the steam sterilization on the three kinds of Ca-P porous bioceramics should be considered carefully based on the above changed properties.

  1. Voluntary sterilization for childfree women: understanding patient profiles, evaluating accessibility, examining legislation.

    PubMed

    Richie, Cristina

    2013-01-01

    Approximately 47 percent of women ages fifteen to forty-four are currently without children, and slightly more than 20 percent of white women in America will never bear children, the highest percentage in modern history. Many fertile women who are childless are voluntarily so. Although any competent person twenty-one years or older is legally eligible for voluntary sterilization, many doctors refuse to sterilize childfree women. This essay explores various reasons a woman would want to continue in her childfree lifestyle, evaluates the accessibility of sterilization for women who are childfree by examining the reported reasons for denial of sterilization-both from the woman's and the physician's perspective-and assesses the legal status of voluntary sterilization for nonparous women. The essay also urges physicians to follow recommended guidelines for counseling women who, regardless of parity, desire sterilization and to provide this contraception if, after careful consideration, there are no outstanding health or other reasons that the procedure should not be performed. © 2013 by The Hastings Center.

  2. Hiding an elephant: heavy sterile neutrino with large mixing angle does not contradict cosmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bezrukov, F.; Chudaykin, A.; Gorbunov, D., E-mail: Fedor.Bezrukov@manchester.ac.uk, E-mail: chudy@ms2.inr.ac.ru, E-mail: gorby@ms2.inr.ac.ru

    We study a model of a keV-scale sterile neutrino with a relatively large mixing with the Standard Model sector. Usual considerations predict active generation of such particles in the early Universe, which leads to constraints from the total Dark Matter density and absence of X-ray signal from sterile neutrino decay. These bounds together may deem any attempt of creation of the keV scale sterile neutrino in the laboratory unfeasible. We argue that for models with a hidden sector coupled to the sterile neutrino these bounds can be evaded, opening new perspectives for the direct studies at neutrino experiments such asmore » Troitsk ν-mass and KATRIN. We estimate the generation of sterile neutrinos in scenarios with the hidden sector dynamics keeping the sterile neutrinos either massless or superheavy in the early Universe. In both cases the generation by oscillations from active neutrinos in plasma is suppressed.« less

  3. Validation study and routine control monitoring of moist heat sterilization procedures.

    PubMed

    Shintani, Hideharu

    2012-06-01

    The proposed approach to validation of steam sterilization in autoclaves follows the basic life cycle concepts applicable to all validation programs. Understand the function of sterilization process, develop and understand the cycles to carry out the process, and define a suitable test or series of tests to confirm that the function of the process is suitably ensured by the structure provided. Sterilization of product and components and parts that come in direct contact with sterilized product is the most critical of pharmaceutical processes. Consequently, this process requires a most rigorous and detailed approach to validation. An understanding of the process requires a basic understanding of microbial death, the parameters that facilitate that death, the accepted definition of sterility, and the relationship between the definition and sterilization parameters. Autoclaves and support systems need to be designed, installed, and qualified in a manner that ensures their continued reliability. Lastly, the test program must be complete and definitive. In this paper, in addition to validation study, documentation of IQ, OQ and PQ concretely were described.

  4. Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization

    PubMed Central

    Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel

    2008-01-01

    Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201

  5. System for creating at a site, remote from a sterile environment, a parenteral solution

    NASA Technical Reports Server (NTRS)

    Scharf, Mike (Inventor); Finley, Mike (Inventor); Veillon, Joe (Inventor); Kipp, Jim (Inventor); Dudar, Tom (Inventor); Owens, Jim (Inventor); Ogle, Jim (Inventor)

    1996-01-01

    The present invention relates to a container, system, and method for creating parenteral solutions at a site, remote from sterile environments. The system includes a flexible container that is empty except for a prepackaged amount of a solute that is housed in the interior of the container. The container includes at least one port and a sterilizing filter in communication with an interior of the port. The container is so constructed and arranged that a fluid flow path is created from the port through the filter and into the interior of the container. A sterile water source including means for establishing fluid flow from the sterile water source into the port is provided. Accordingly, sterile water can flow from the sterile water source through the filter into the container where it is mixed with the solute to create a parenteral solution that can then be infused into a patient. A method and container are also provided.

  6. A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization.

    PubMed

    Kanemitsu, Keiji; Imasaka, Takayuki; Ishikawa, Shiho; Kunishima, Hiroyuki; Harigae, Hideo; Ueno, Kumi; Takemura, Hiromu; Hirayama, Yoshihiro; Kaku, Mitsuo

    2005-05-01

    To compare the efficacies of ethylene oxide gas (EOG), hydrogen peroxide gas plasma (PLASMA), and low-temperature steam formaldehyde (LTSF) sterilization methods. The efficacies of EOG, PLASMA, and LTSF sterilization were tested using metal and plastic plates, common medical instruments, and three process challenge devices with narrow lumens. All items were contaminated with Bacillus stearothermophilus spores or used a standard biological indicator. EOG and LTSF demonstrated effective killing of B. stearothermophilus spores, with or without serum, on plates, on instruments, and in process challenge devices. PLASMA failed to adequately sterilize materials on multiple trials in several experiments, including two of three plates, two of three instruments, and all process challenge devices. Our results suggest that PLASMA sterilization may be unsuccessful under certain conditions, particularly when used for items with complex shapes and narrow lumens. Alternatively, LTSF sterilization demonstrates excellent efficacy and is comparable to EOG sterilization. LTSF could potentially act as a substitute if EOG becomes unavailable due to environmental concerns.

  7. On the difficulties of discriminating between major and minor hybrid male sterility factors in Drosophila by examining the segregation ratio of sterile and fertile sons in backcrossing experiments.

    PubMed

    Maside, X R; Naveira, H F

    1996-10-01

    The observation of segregation ratios of sterile and fertile males in offspring samples from backcrossed hybrid females is, in principle, a valid method to unveil the genetic basis of hybrid male sterility in Drosophila. When the female parent is heterozygous (hybrid) for a sterility factor with major effects, equal proportions of fertile and sterile sons are expected in her offspring. However, intact (not recombined) chromosome segments of considerable length are expected to give segregation ratios that can not be easily differentiated from the 1:1 ratio expected from a single factor. When the phenotypic character under analysis can be determined by combinations of minor factors from the donor species spanning a certain chromosome length, very large offspring samples may be needed to test this alternative hypothesis against the null hypothesis of a single major factor. This is particularly the case of hybrid male sterility determinants in Drosophila.

  8. Genome-wide misexpression of X-linked versus autosomal genes associated with hybrid male sterility

    PubMed Central

    Lu, Xuemei; Shapiro, Joshua A.; Ting, Chau-Ti; Li, Yan; Li, Chunyan; Xu, Jin; Huang, Huanwei; Cheng, Ya-Jen; Greenberg, Anthony J.; Li, Shou-Hsien; Wu, Mao-Lien; Shen, Yang; Wu, Chung-I

    2010-01-01

    Postmating reproductive isolation is often manifested as hybrid male sterility, for which X-linked genes are overrepresented (the so-called large X effect). In contrast, X-linked genes are significantly under-represented among testis-expressing genes. This seeming contradiction may be germane to the X:autosome imbalance hypothesis on hybrid sterility, in which the X-linked effect is mediated mainly through the misexpression of autosomal genes. In this study, we compared gene expression in fertile and sterile males in the hybrids between two Drosophila species. These hybrid males differ only in a small region of the X chromosome containing the Ods-site homeobox (OdsH) (also known as Odysseus) locus of hybrid sterility. Of genes expressed in the testis, autosomal genes were, indeed, more likely to be misexpressed than X-linked genes under the sterilizing action of OdsH. Since this mechanism of X:autosome interaction is only associated with spermatogenesis, a connection between X:autosome imbalance and the high rate of hybrid male sterility seems plausible. PMID:20511493

  9. Genome-wide misexpression of X-linked versus autosomal genes associated with hybrid male sterility.

    PubMed

    Lu, Xuemei; Shapiro, Joshua A; Ting, Chau-Ti; Li, Yan; Li, Chunyan; Xu, Jin; Huang, Huanwei; Cheng, Ya-Jen; Greenberg, Anthony J; Li, Shou-Hsien; Wu, Mao-Lien; Shen, Yang; Wu, Chung-I

    2010-08-01

    Postmating reproductive isolation is often manifested as hybrid male sterility, for which X-linked genes are overrepresented (the so-called large X effect). In contrast, X-linked genes are significantly under-represented among testis-expressing genes. This seeming contradiction may be germane to the X:autosome imbalance hypothesis on hybrid sterility, in which the X-linked effect is mediated mainly through the misexpression of autosomal genes. In this study, we compared gene expression in fertile and sterile males in the hybrids between two Drosophila species. These hybrid males differ only in a small region of the X chromosome containing the Ods-site homeobox (OdsH) (also known as Odysseus) locus of hybrid sterility. Of genes expressed in the testis, autosomal genes were, indeed, more likely to be misexpressed than X-linked genes under the sterilizing action of OdsH. Since this mechanism of X:autosome interaction is only associated with spermatogenesis, a connection between X:autosome imbalance and the high rate of hybrid male sterility seems plausible.

  10. [Dynamic model of seasonal breeding rodent pest population controlled with short-acting sterilant].

    PubMed

    Liu, Han-wu; Jin, Zhen; Zhang, Feng-qin; Li, Qiu-ying

    2013-04-01

    Rodent pests bring great damage to human beings, while rodenticide and sterilant can be used to control the pests. After ingesting sterilant, rodent pests lose their fertility, but in some cases, the sterile individuals may gain their fertility again, produce offspring, and enlarge population size. In this paper, the dynamic models of rodent pest population under lethal control and shortacting contraception control were formulated, and, with the prerequisite of the seasonal breeding of rodent pest population, the models were used to regularly analyze their behaviors and the effects of the contraception rate, lethal rate, control interval, and sterilant valid period on the dynamics of the pest population. The results showed that larger contraception rate and lethal rate and shorter control interval could have better control effect, making the controlled population become smaller and even died out. Short-acting sterilant limited the control effect. At the later period of breeding season, the rodent pest population controlled with short-acting sterilant would have a weak recovery.

  11. The economics of race and eugenic sterilization in North Carolina: 1958-1968.

    PubMed

    Price, Gregory N; Darity, William A

    2010-07-01

    Theoretical justifications for state-sanctioned sterilization of individuals provided by Irving Fisher rationalized its racialization on grounds that certain non-white racial groups, particularly blacks due to their dysgenic biological and behavioral traits, retarded economic growth and should be bred out of existence. Fisher's rationale suggests that national or state level eugenic policies that sterilized the so-called biological and genetically unfit could have been racist in both design and effect by disproportionately targeting black Americans. We empirically explore this with data on eugenic sterilizations in the State of North Carolina between 1958 and 1968. Count data parameter estimates from a cross-county population allocation model of sterilization reveal that the probability of non-institutional and total sterilizations increased with a county's black population share-an effect not found for any other racial group in the population. Our results suggest that in North Carolina, eugenic sterilization policies were racially biased and genocidal. 2010 Elsevier B.V. All rights reserved.

  12. The possible contamination of Jupiter

    NASA Technical Reports Server (NTRS)

    Garcia, Joe

    1988-01-01

    The Galileo probe, though at present its future is uncertain, would, if not sterilized, represent a good chance of contaminating Jupiter. Most scientists opposed to sterilizing the probe argue that to order the probe sterilized would be the death of the project, since sterilization would entail a reconstruction of the probe, and there are not enough funds to accomplish this. These scientists, however, are ignoring a relatively simple and inexpensive alternative to the traditional heat sterilization method. The main threat of contamination comes from Galileo's exterior surfaces: the shell of the probe and its parachute. The probe innermost components would not represent a threat since the probe is sealed. In light of the fact that only the exterior of Galileo would have to be sterilized, heat would not have to be used as a method of sterilization. Instead, various gas mixtures could be sprayed entirely over the probe and its parachute, gases which would kill any and all bacteria. This idea is more thoroughly examined.

  13. Continuous sterilization of plumbing systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Moyers, C. V.; Wright, E. E., Jr.

    1979-01-01

    Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.

  14. Effect of sterilization on stiffness and dimensional stability of rubber-dam clamps.

    PubMed

    Giebink, D L; Mathieu, G P; Hondrum, S O

    1996-01-01

    Simulated clinical conditions were used to test the effect of sterilization on rubber-dam clamp stiffness and dimension. Sixty Hygienic and Ivory W7 clamps were either steam or dry heat sterilized and compared to controls. Stiffness and dimensional change between Ivory clamp groups was significant (p<.0001); the sterilized clamps showed less change than the controls. Hygienic groups showed a significant different between the control and dry heat groups (p<.05); the sterilized clamps showed less change than the controls. The change in stiffness and interjaw width for all Ivory clamps compared to all Hygienic clamps was significant (p<.0001). The Hygienic clamps changes less than the Ivory clamps. The results indicate that steam and dry heat sterilization do not affect retention of rubber-dam clamps.

  15. Effects of X-ray irradiation on human spermatogenesis

    NASA Technical Reports Server (NTRS)

    Thorslund, T. W.; Paulsen, C. A.

    1972-01-01

    Direct cell kill and inhibition of mitosis have been suggested as mechanisms to explain the occurrence of absolute sterility following the irradiation of the testes. In order to obtain information on the existence and dose dependency of the mechanisms for man, a controlled study was initiated. Sixty-four men received a single midorgan dose to both of their testes ranging from 7.5 to 400r (f = .95). It was deduced from resulting pre-sterile period and sterile period data that both cell kill and mitosis halting mechanisms were operating. The maximum observed sterile period was 501 days with eventual recovery observed in each individual where the follow-up was complete. Thus man appears to be highly radiosensitive in regard to temporary sterility but quite radioresistant in regard to permanent sterility.

  16. Simultaneous Sterilization With Surface Modification Of Plastic Bottle By Plasma-Based Ion Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakudo, N.; Ikenaga, N.; Ikeda, F.

    2011-01-07

    Dry sterilization of polymeric material is developed. The technique utilizes the plasma-based ion implantation which is same as for surface modification of polymers. Experimental data for sterilization are obtained by using spores of Bacillus subtilis as samples. On the other hand we previously showed that the surface modification enhanced the gas barrier characteristics of plastic bottles. Comparing the implantation conditions for the sterilization experiment with those for the surface modification, we find that both sterilization and surface modification are simultaneously performed in a certain range of implantation conditions. This implies that the present bottling system for plastic vessels will bemore » simplified and streamlined by excluding the toxic peroxide water that has been used in the traditional sterilization processes.« less

  17. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, C.E.

    1999-02-09

    A method is described for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process. 2 figs.

  18. Gamma sterilization of pharmaceuticals--a review of the irradiation of excipients, active pharmaceutical ingredients, and final drug product formulations.

    PubMed

    Hasanain, Fatima; Guenther, Katharina; Mullett, Wayne M; Craven, Emily

    2014-01-01

    Sterilization by gamma irradiation has shown a strong applicability for a wide range of pharmaceutical products. Due to the requirement for terminal sterilization where possible in the pharmaceutical industry, gamma sterilization has proven itself to be an effective method as indicated by its acceptance in the European Pharmacopeia and the United States Pharmacopeia ( ). Some of the advantages of gamma over competitive procedures include high penetration power, isothermal character (small temperature rise), and no residues. It also provides a better assurance of product sterility than aseptic processing, as well as lower validation demands. Gamma irradiation is capable of killing microorganisms by breaking their chemical bonds, producing free radicals that attack the nucleic acid of the microorganism. Sterility by gamma irradiation is achieved mainly by the alteration of nucleic acid and preventing the cellular division. This review focuses on the extensive application of gamma sterilization to a wide range of pharmaceutical components including active pharmaceutical ingredients, excipients, final drug products, and combination drug-medical devices. A summary of the published literature for each class of pharmaceutical compound or product is presented. The irradiation conditions and various quality control characterization methodologies that were used to determine final product quality are included, in addition to a summary of the investigational outcomes. Based on this extensive literature review and in combination with regulatory guidelines and other published best practices, a decision tree for implementation of gamma irradiation for pharmaceutical products is established. This flow chart further facilitates the implementation of gamma irradiation in the pharmaceutical development process. The summary therefore provides a useful reference to the application and versatility of gamma irradiation for pharmaceutical sterilization. Many pharmaceutical products require sterilization to ensure their safe and effective use. Sterility is therefore a critical quality attribute and is essential for direct injection products. Due to the requirement for terminal sterilization, where possible in the pharmaceutical industry sterilization by gamma irradiation has been commonly used as an effective method to sterilize pharmaceutical products as indicated by its acceptance in the European Pharmacopeia. Gamma sterilization is a very attractive terminal sterilization method in view of its ability to attain 10(-6) probability of microbial survival without excessive heating of the product or exposure to toxic chemicals. However, radiation compatibility of a product is one of the first aspects to evaluate when considering gamma sterilization. Gamma radiation consists of high-energy photons that result in the generation of free radicals and the subsequent ionization of chemical bonds, leading to cleavage of DNA in microorganisms and their subsequent inactivation. This can result in a loss of active pharmaceutical ingredient potency, the creation of radiolysis by-products, a reduction of the molecular weight of polymer excipients, and influence drug release from the final product. There are several strategies for mitigating degradation effects, including optimization of the irradiation dose and conditions. This review will serve to highlight the extensive application of gamma sterilization to a broad spectrum of pharmaceutical components including active pharmaceutical ingredients, excipients, final drug products, and combination drug-medical devices.

  19. ACOG Practice bulletin no. 133: benefits and risks of sterilization.

    PubMed

    2013-02-01

    Female and male sterilization are both safe and effective methods of permanent contraception used by more than 220 million couples worldwide . Approximately 600,000 tubal occlusions and 200,000 vasectomies are performed in the United States annually . For women seeking permanent contraception, sterilization obviates the need for user-dependent contraception throughout their reproductive years and provides an excellent alternative for those with medical contraindications to reversible methods. The purpose of this document is to review the evidence for the safety and effectiveness of female sterilization in comparison with male sterilization and other forms of contraception.

  20. Sterile neutrino dark matter with supersymmetry

    NASA Astrophysics Data System (ADS)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  1. Sterile neutrino searches via displaced vertices at LHCb

    NASA Astrophysics Data System (ADS)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2017-11-01

    We explore the sensitivity of displaced vertex searches at LHCb for testing sterile neutrino extensions of the Standard Model towards explaining the observed neutrino masses. We derive estimates for the constraints on sterile neutrino parameters from a recently published displaced vertex search at LHCb based on run 1 data. They yield the currently most stringent limit on active-sterile neutrino mixing in the sterile neutrino mass range between 4.5 GeV and 10 GeV. Furthermore, we present forecasts for the sensitivities that could be obtained from the run 2 data and also for the high-luminosity phase of the LHC.

  2. Degradation of Biochemical Activity in Soil Sterilized by Dry Heat and Gamma Radiation

    NASA Technical Reports Server (NTRS)

    Shih, K. L.; Souza, K. A.

    1978-01-01

    The effect of soil sterilization by dry heat (0.08% relative humidity), gamma radiation, or both on soil phosphatase, urease, and decarboxylase activity was studied. Soil sterilized by a long exposure to dry heat at relatively low temperatures (eight weeks at 100.5 C) retained higher activities than did soil exposed to a higher temperature (two weeks at 124.5 C), while all activity was destroyed by four days at 148.5 C. Sterilization with 7.5 Mrads destroyed less activity than did heat sterilization. The effect of several individually nonsterizing doses of heat radiation is described.

  3. [The influence of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 nickel-titanium rotary instruments].

    PubMed

    Li, Xiang-fen; Zheng, Ping; Xu, Li; Su, Qin

    2015-12-01

    To investigate the effects of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 types of nickel-titanium rotary instruments (K3, Mtwo, ProTaper). Three brands of NiTi rotary endodontic instruments of the same size (tip diameter 0.25 mm and constant 0.06 taper) were selected: K3, Mtwo and Protaper (F2). 24 instruments for each brand were used to evaluate the effects of autoclave sterilization on inner character in the as-received condition and after subjection to 0, 1, 5, and 10 sterilization cycles (6 for each group). Time to fracture (TtF) from the start of the test to the moment of file breakage and the length of the fractured fragment were recorded. Means and standard deviations of TtF and fragment length were calculated. The data was analyzed with SPSS13.0 software package. Another 12 NiTi rotary instruments for each brand were used, 6 subjected to 10 autoclave sterilization cycles and the other as control. Scanning electron microscope was used to observe the changes in surface topography and inner character. For cyclic fatigue resistance, when sterilization was not performed, K3 showed the highest value of TtF means and ProTaper the lowest. The differences between each brand were statistically significant (P<0.05).When disinfection was performed, K3 brand showed greater fatigue resistance in comparison with the control when autoclave sterilization cycled 5 times and 10 times. The difference between 10 cycles of sterilization and the control was statistically significant (P<0.05); ProTaper brand showed significantly greater fatigue resistance in all the disinfected groups compared with the control (P<0.05) and 5 cycles of sterilization led to the greatest increment; The fatigue resistance of Mtwo brands increased with sterilization cycles and the difference between 5/10 cycles and the control were statistically significant (P<0.05). For surface characteristics, under scanning electron microscope, surface and inner imperfections in all instruments were intensified greatly after 10 cycles of sterilization. Cycle fatigue resistance is different among instruments of different brands. Autoclave sterilization may increase fatigue resistance of the 3 brands. Autoclave sterilization may increase the surface roughness and inner defects in cross section.

  4. Sterilizing the Poor

    ERIC Educational Resources Information Center

    Rothman, Sheila M.

    1977-01-01

    Suggests that freedom for the middle classes may mean vulnerability for the poor. The enthusiasm for sterilization may be so intense as to deprive the poor of their right not to be sterilized. (Author/AM)

  5. Development of vapor phase hydrogen peroxide sterilization process for spacecraft applications

    NASA Technical Reports Server (NTRS)

    Rohatgi, N.; Schubert, W.; Knight, J.; Quigley, M.; Forsberg, G.; Ganapathi, G.; Yarbrough, C.; Koukol, R.

    2001-01-01

    This paper will present test data and discussion on the work we are conducting at JPL to address the following issues: 1) efficacy of sterilization process; 2) diffusion of hydrogen peroxide under sterilization process conditions into hard to reach places; 3) materials and components compatibility with the sterilization process and 4) development of methodology to protect sensitive components from hydrogen peroxide vapor.

  6. Guidelines for Water Quality Laboratory Operations.

    DTIC Science & Technology

    1985-07-01

    Semiannually sample cell pressure gauge Autoclaves and Check sterilization effectiveness Daily sterilizers (e.g., B. stearothermophilus , color-indicator...container should have been previously cleaned with chromic acid solution as described previously. Treat the container caps similarly. C. Sterilization . For...microbiological analyses, sterilize the container and its stopper/cap by autoclaving at 121*C for 15 min or by dry heat at 180C for 2 hr. Heat-sensitive

  7. Monitor for Sterilization Procedures

    DTIC Science & Technology

    2001-10-25

    were tested using ampules of Bacillus stearothermophilus spores commercially manufactured by Barnstead/Thermolyne for testing sterilization procedures...Monitor for Sterilization Procedures F. Cleary1,2, H.-Y. Mason2, C. Estes2, A. Duncan2, W. Ellis, Jr.2 and L. Powers2 1Moses Brown High School...accurate determination of the efficacy of sterilization procedures is demonstrated using a hand-held instrument based on the intrinsic fluorescence of

  8. Sterilization of silicone-based hydrogels for biomedical application using ozone gas: Comparison with conventional techniques.

    PubMed

    Galante, Raquel; Ghisleni, Daniela; Paradiso, Patrizia; Alves, Vitor D; Pinto, Terezinha J A; Colaço, Rogério; Serro, Ana Paula

    2017-09-01

    Sterilization of hydrogels is challenging due to their often reported sensitivity to conventional methods involving heat or radiation. Although aseptic manufacturing is a possibility, terminal sterilization is safer in biological terms, leading to a higher overall efficiency, and thus should be used whenever it is possible. The main goal of this work was to study the applicability of an innovative ozone gas terminal sterilization method for silicone-based hydrogels and compare its efficacy and effects with those of traditional sterilization methods: steam heat and gamma irradiation. Ozone gas sterilization is a method with potential interest since it is reported as a low cost green method, does not leave toxic residues and can be applied to thermosensitive materials. A hydrogel intended for ophthalmological applications, based on tris(trimethylsiloxy)silyl] propyl methacrylate, was prepared and extensively characterized before and after the sterilization procedures. Alterations regarding transparency, swelling, wettability, ionic permeability, friction coefficient, mechanical properties, topography and morphology and chemical composition were monitored. Efficacy of the ozonation was accessed by performing controlled contaminations and sterility tests. In vitro cytotoxicity testes were also performed. The results show that ozonation may be applied to sterilize the studied material. A treatment with 8 pulses allowed sterilizing the material with bioburdens≤10 3 CFU/mL, preserving all the studied properties within the required known values for contact lenses materials. However, a higher exposure (10 pulses) led to some degradation of the material and induced mild cytotoxicity. Steam heat sterilization led to an increase of swelling capacity and a decrease of the water contact angle. Regarding gamma irradiation, the increase of irradiation dose led to an increase of the friction coefficient. The higher dose (25kGy) originated surface degradation and affected the mechanical properties of the hydrogel by inducing a significant increase of the Young's modulus. Overall, the results show that ozonation may be considered as a valid and promising alternative for the sterilization of silicon-based hydrogels for biomedical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    PubMed

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  10. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    PubMed

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of a wild female population. However, further trials in field conditions with wild males and females should be undertaken to estimate the ratio of sterile males to wild males required to produce an effect on wild populations.

  11. Sterile flowers increase pollinator attraction and promote female success in the Mediterranean herb Leopoldia comosa

    PubMed Central

    Morales, Carolina L.; Traveset, Anna; Harder, Lawrence D.

    2013-01-01

    Background and Aims Large floral displays have opposing consequences for animal-pollinated angiosperms: they attract more pollinators but also enable elevated among-flower self-pollination (geitonogamy). The presence of sterile flowers as pollinator signals may enhance attraction while allowing displays of fewer open fertile flowers, limiting geitonogamy. The simultaneous contributions of fertile and non-fertile display components to pollinator attraction and reproductive output remain undetermined. Methods The simultaneous effects of the presence of sterile flowers and fertile-flower display size in two populations of Leopoldia comosa were experimentally assessed. Pollinator behaviour, pollen removal and deposition, and fruit and seed production were compared between intact plants and plants with sterile flowers removed. Key Results The presence of sterile flowers almost tripled pollinator attraction, supplementing the positive effect of the number of fertile flowers on the number of bees approaching inflorescences. Although attracted bees visited more flowers on larger inflorescences, the number visited did not additionally depend on the presence of sterile flowers. The presence of sterile flowers improved all aspects of plant performance, the magnitude of plant benefit being context dependent. During weather favourable to pollinators, the presence of sterile flowers increased pollen deposition on stigmas of young flowers, but this difference was not evident in older flowers, probably because of autonomous self-pollination in poorly visited flowers. Total pollen receipt per stigma decreased with increasing fertile display size. In the population with more pollinators, the presence of sterile flowers increased fruit number but not seed set or mass, whereas in the other population sterile flowers enhanced seeds per fruit, but not fruit production. These contrasts are consistent with dissimilar cross-pollination and autonomous self-pollination, coupled with the strong predispersal inbreeding depression exhibited by L. comosa populations. Conclusions Sterile flowers enrich pollination quality by promoting pollen export and import, while limiting the mating costs of geitonogamy associated with large fertile displays. PMID:23131298

  12. The Use of Long Acting Reversible Contraceptives and the Relationship between Discontinuation Rates due to Menopause and to Female and Male Sterilizations.

    PubMed

    Ferreira, Jessica Mayra; Monteiro, Ilza; Castro, Sara; Villarroel, Marina; Silveira, Carolina; Bahamondes, Luis

    2016-05-01

    Introduction Women require effective contraception until they reach menopause. The long acting reversible contraceptives (LARC) and the depot-medroxyprogesterone acetate (DMPA, Depo-Provera®, Pfizer, Puurs, Belgium) are great options and can replace possible sterilizations. Purpose To assess the relationship between the use of LARCs and DMPA and terminations ascribed to menopause and sterilizations in a Brazilian clinic. Methods We reviewed the records of women between 12 and 50 years of age attending the clinic that chose to use a LARC method or DMPA. Cumulative termination rates due to sterilization or because the woman had reached menopause were computed using single decrement life-table analysis over 32 years. We also examined all records of surgical sterilization at our hospital between the years 1980-2012. Results Three hundred thirty-two women had continuously used the same contraceptive until menopause, and 555 women had discontinued the method because they or their partners underwent sterilization. From year 20 to year 30 of use, levonorgestrel intrauterine-releasing system (LNG-IUS - Mirena®, Bayer Oy, Turku, Finland; available since 1980), copper intrauterine device (IUD - available since 1980) and DMPA users showed a trend of cumulative higher discontinuation rates due to menopause when compared with the discontinuation rates due to sterilization. Over the study period, a steep decline in the use of sterilization occurred. Conclusion Over the past 15 years of research we have observed a trend: women usually preferred to continue using LARC methods or DMPA until menopause rather than decide for sterilization, be it their own, or their partners'. The annual number of sterilizations dropped in the same period. The use of LARC methods and DMPA until menopause is an important option to avoid sterilization, which requires a surgical procedure with potential complications. Thieme Publicações Ltda Rio de Janeiro, Brazil.

  13. Construction of a multicontrol sterility system for a maize male-sterile line and hybrid seed production based on the ZmMs7 gene encoding a PHD-finger transcription factor.

    PubMed

    Zhang, Danfeng; Wu, Suowei; An, Xueli; Xie, Ke; Dong, Zhenying; Zhou, Yan; Xu, Liwen; Fang, Wen; Liu, Shensi; Liu, Shuangshuang; Zhu, Taotao; Li, Jinping; Rao, Liqun; Zhao, Jiuran; Wan, Xiangyuan

    2018-02-01

    Although hundreds of genetic male sterility (GMS) mutants have been identified in maize, few are commercially used due to a lack of effective methods to produce large quantities of pure male-sterile seeds. Here, we develop a multicontrol sterility (MCS) system based on the maize male sterility 7 (ms7) mutant and its wild-type Zea mays Male sterility 7 (ZmMs7) gene via a transgenic strategy, leading to the utilization of GMS in hybrid seed production. ZmMs7 is isolated by a map-based cloning approach and encodes a PHD-finger transcription factor orthologous to rice PTC1 and Arabidopsis MS1. The MCS transgenic maintainer lines are developed based on the ms7-6007 mutant transformed with MCS constructs containing the (i) ZmMs7 gene to restore fertility, (ii) α-amylase gene ZmAA and/or (iii) DNA adenine methylase gene Dam to devitalize transgenic pollen, (iv) red fluorescence protein gene DsRed2 or mCherry to mark transgenic seeds and (v) herbicide-resistant gene Bar for transgenic seed selection. Self-pollination of the MCS transgenic maintainer line produces transgenic red fluorescent seeds and nontransgenic normal colour seeds at a 1:1 ratio. Among them, all the fluorescent seeds are male fertile, but the seeds with a normal colour are male sterile. Cross-pollination of the transgenic plants to male-sterile plants propagates male-sterile seeds with high purity. Moreover, the transgene transmission rate through pollen of transgenic plants harbouring two pollen-disrupted genes is lower than that containing one pollen-disrupted gene. The MCS system has great potential to enhance the efficiency of maize male-sterile line propagation and commercial hybrid seed production. © 2017 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  14. Lack of insurance and parity influence choice between long-acting reversible contraception and sterilization in women postpregnancy.

    PubMed

    Baldwin, Maureen K; Rodriguez, Maria I; Edelman, Alison B

    2012-07-01

    Disparities in postpregnancy contraception utilization exist, with low-income women disproportionately undergoing sterilization. We assessed the impact of increased intrauterine device (IUD) availability on rates of female sterilization. Hospital billing records were used to identify women with an IUD placement or sterilization within 1 year of a pregnancy at a university hospital between Oct 2005 and Jun 2007. Demographic data were compared between women receiving either an IUD or sterilization. There were 365 sterilizations and 223 IUD placements during the study period. IUD placements doubled over the study period from 6% to 12% of all deliveries, while sterilizations remained stable at 11% (p<.001). Demographic variables were examined for women with either public or private insurance who had financial access to both sterilization (n=253) and IUD (n=223). Women receiving sterilization were slightly older (mean age 31 years versus 30 years, p=.03), of higher parity (median three versus two, p<.01), more likely to have had cesarean delivery (69% versus 31%, p<.001) and more likely to have public insurance (77% versus 23%, p<.001) than women who received IUD. Approximately 45% of women delivering in Oregon in 2007 were publicly insured (2010 Maternal and Child Health Update: States Make Progress Towards Improving Systems of Care. National Governor's Association, Table 6. Available at http://www.nga.org/files/live/sites/NGA/files/pdf/MCHUPDATE2010.PDF, accessed Nov 2011). After adjusting for age, parity and type of delivery, women choosing sterilization were more likely to have public insurance than women choosing IUD (odds ratio 8.4, 95% confidence interval 4.7-14.9, p<.0001). Women choosing sterilization are more likely to have public insurance than women choosing IUD and may represent a continued trend toward nonreversible contraception among women of lower socioeconomic status despite available long-acting reversible methods. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. The Sterile Insect Technique for Controlling Populations of Aedes albopictus (Diptera: Culicidae) on Reunion Island: Mating Vigour of Sterilized Males

    PubMed Central

    Oliva, Clelia F.; Jacquet, Maxime; Gilles, Jeremie; Lemperiere, Guy; Maquart, Pierre-Olivier; Quilici, Serge; Schooneman, François; Vreysen, Marc J. B.; Boyer, Sebastien

    2012-01-01

    Reunion Island suffers from high densities of the chikungunya and dengue vector Aedes albopictus. The sterile insect technique (SIT) offers a promising strategy for mosquito-borne diseases prevention and control. For such a strategy to be effective, sterile males need to be competitive enough to fulfil their intended function by reducing wild mosquito populations in natura. We studied the effect of irradiation on sexual maturation and mating success of males, and compared the sexual competitiveness of sterile versus wild males in the presence of wild females in semi-field conditions. For all untreated or sterile males, sexual maturation was completed within 13 to 20 h post-emergence and some males were able to inseminate females when 15 h old. In the absence of competition, untreated and sterile males were able to inseminate the same number of virgin females during 48 h, in small laboratory cages: an average of 93% of females was inseminated no matter the treatment, the age of males, and the sex ratio. Daily mating success of single sterile males followed the same pattern as for untreated ones, although they inseminated significantly fewer females after the ninth day. The competitiveness index of sterile males in semi-field conditions was only 0.14 when they were released at 1-day old, but improved to 0.53 when the release occurred after a 5-day period in laboratory conditions. In SIT simulation experiments, a 5∶1 sterile to wild male ratio allowed a two-fold reduction of the wild population’s fertility. This suggests that sterile males could be sufficiently competitive to mate with wild females within the framework of an SIT component as part of an AW-IPM programme for suppressing a wild population of Ae. albopictus in Reunion Island. It will be of interest to minimise the pre-release period in controlled conditions to ensure a good competitiveness without increasing mass rearing costs. PMID:23185329

  16. Red oak borers become sterile when reared under continuous light

    Treesearch

    Jimmy R. Galford

    1975-01-01

    Red oak borers, Enaphalodes rufulus (Haldeman), reared under continuous light for 12 weeks became sterile. Sterility is thought to have been caused by light destroying vitamins essential for fertility

  17. Geographic variation in characteristics of postpartum women using female sterilization

    PubMed Central

    White, Kari; Potter, Joseph E.; Zite, Nikki

    2015-01-01

    Background Southern states have higher rates of female sterilization compared to other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. Methods We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women’s contraceptive method use between 2006–2009. We categorized states according to geographic region: South, Midwest/West and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. Findings The percentage of postpartum women using sterilization ranged from 5.0–9.9% in the Northeast, 8.9–10.6% in the Midwest/West and 11.6–22.4% in the South. Women in nearly all sub-groups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no significant differences in the prevalence of sterilization for Blacks compared to Whites in the Northeast (0.76 [95% CI: 0.55–1.06]), Midwest/West (0.91 [95%CI: 0.80–1.04]) and South (0.96 [95%CI: 0.85–1.07]). Women with Medicaid-paid deliveries (versus private insurance) had a higher prevalence of sterilization in all regions (p<0.05). Conclusions These findings do not indicate that low-income and racial/ethnic minority women in the South use sterilization at disproportionately higher rates compared to other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. PMID:26232310

  18. Reducing the radiation sterilization dose improves mechanical and biological quality while retaining sterility assurance levels of bone allografts.

    PubMed

    Nguyen, Huynh; Cassady, Alan I; Bennett, Michael B; Gineyts, Evelyne; Wu, Andy; Morgan, David A F; Forwood, Mark R

    2013-11-01

    Bone allografts carry a risk of infection, so terminal sterilization by gamma irradiation at 25kGy is recommended; but is deleterious to bone quality. Contemporary bone banking significantly reduces initial allograft bioburden, questioning the need to sterilize at 25kGy. We inoculated allograft bone with Staphylococcus epidermidis and Bacillus pumilus, then exposed them to gamma irradiation at 0, 5, 10, 15, 20 and 25kGy. Mechanical and biological properties of allografts were also assessed. Our aim was to determine an optimal dose that achieves sterility assurance while minimizing deleterious effects on allograft tissue. 20-25kGy eliminated both organisms at concentrations from 10(1) to 10(3)CFU, while 10-15kGy sterilized bone samples to a bioburden concentration of 10(2)CFU. Irradiation did not generate pro-inflammatory bone surfaces, as evidenced by macrophage activation, nor did it affect attachment or proliferation of osteoblasts. At doses ≥10kGy, the toughness of cortical bone was reduced (P<0.05), and attachment and fusion of osteoclasts onto irradiated bone declined at 20 and 25kGy (P<0.05). There was no change in collagen cross-links, but a significant dose-response increase in denatured collagen (P<0.05). Our mechanical and cell biological data converge on 15kGy as a threshold for radiation sterilization of bone allografts. Between 5 and 15kGy, bone banks can undertake validation that provides allografts with an acceptable sterility assurance level, improving their strength and biocompatibility significantly. The application of radiation sterilization doses between 5 and 15kGy will improve bone allograft mechanical performance and promote integration, while retaining sterility assurance levels. Improved quality of allograft bone will promote superior clinical outcomes. © 2013.

  19. History of sterile compounding in U.S. hospitals: learning from the tragic lessons of the past.

    PubMed

    Myers, Charles E

    2013-08-15

    The evolution of sterile compounding in the context of hospital patient care, the evolution of related technology, past incidents of morbidity and mortality associated with preparations compounded in various settings, and efforts over the years to improve compounding practices are reviewed. Tightened United States Pharmacopeial Convention standards (since 2004) for sterile compounding made it difficult for hospitals to achieve all of the sterile compounding necessary for patient care. Shortages of manufactured injections added to the need for compounding. Non-hospital-based compounding pharmacies increased sterile compounding to meet the needs. Gaps in federal and state laws and regulations about compounding pharmacies led to deficiencies in their regulation. Lapses in sterility led to injuries and deaths. Perspectives offered include potential actions, including changes in practitioner education, better surveillance of sterile compounding, regulatory reforms, reexamination of the causes of drug shortages, and the development of new technologies. Over the years, there have been numerous exhortations for voluntary better performance in sterile compounding. In addition, professional leadership has been vigorous and extensive in the form of guidance, publications, education, enforceable standards, and development of various associations and organizations dealing with safe compounding practices. Yet problems continue to occur. We must engage in diligent learning from the injuries and tragedies that have occurred. Assuming that we are already doing all we can to avoid problems would be an abdication of the professional mission of pharmacists. It would be wrong thinking to assume that the recent problems in large-scale compounding pharmacies are the only problems that warrant attention. It is time for a systematic assessment of the nature and the dimensions of the problems in every type of setting where sterile compounding occurs. It also is time for some innovative thinking about ensuring safety in sterile compounding.

  20. The pachytene checkpoint and its relationship to evolutionary patterns of polyploidization and hybrid sterility.

    PubMed

    Li, X C; Barringer, B C; Barbash, D A

    2009-01-01

    Sterility is a commonly observed phenotype in interspecific hybrids. Sterility may result from chromosomal or genic incompatibilities, and much progress has been made toward understanding the genetic basis of hybrid sterility in various taxa. The underlying mechanisms causing hybrid sterility, however, are less well known. The pachytene checkpoint is a meiotic surveillance system that many organisms use to detect aberrant meiotic products, in order to prevent the production of defective gametes. We suggest that activation of the pachytene checkpoint may be an important mechanism contributing to two types of hybrid sterility. First, the pachytene checkpoint may form the mechanistic basis of some gene-based hybrid sterility phenotypes. Second, the pachytene checkpoint may be an important mechanism that mediates chromosomal-based hybrid sterility phenotypes involving gametes with non-haploid (either non-reduced or aneuploid) chromosome sets. Studies in several species suggest that the strength of the pachytene checkpoint is sexually dimorphic, observations that warrant future investigation into whether such variation may contribute to differences in patterns of sterility between male and female interspecific hybrids. In addition, plants seem to lack the pachytene checkpoint, which correlates with increased production of unreduced gametes and a higher incidence of polyploid species in plants versus animals. Although the pachytene checkpoint occurs in many animals and in fungi, at least some of the genes that execute the pachytene checkpoint are different among organisms. This finding suggests that the penetrance of the pachytene checkpoint, and even its presence or absence can evolve rapidly. The surprising degree of evolutionary flexibility in this meiotic surveillance system may contribute to the observed variation in patterns of hybrid sterility and in rates of polyploidization.

  1. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.

    PubMed

    Plotino, Gianluca; Costanzo, Alberto; Grande, Nicola M; Petrovic, Renata; Testarelli, Luca; Gambarini, Gianluca

    2012-02-01

    The purpose of this study was to evaluate the effect of autoclave sterilization on cyclic fatigue resistance of rotary endodontic instruments made of traditional and new nickel-titanium (NiTi) alloys. Four NiTi rotary endodontic instruments of the same size (tip diameter 0.40 mm and constant .04 taper) were selected: K3, Mtwo, Vortex, and K3 XF prototypes. Each group was then divided into 2 subgroups, unsterilized instruments and sterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve files from each different subgroup were tested for cyclic fatigue resistance. Means and standard deviations of number of cycles to failure (NCF) and fragment length of the fractured tip were calculated for each group, and data were statistically analyzed (P < .05). Comparing the results between unsterilized and sterilized instruments for each type of file, differences were statistically significant (P < .05) only between sterilized and unsterilized K3XF files (762 versus 651 NCF). The other instruments did not show significant differences (P > .05) in the mean NCF as a result of sterilization cycles (K3, 424 versus 439 NCF; Mtwo, 409 versus 419 NCF; Vortex, 454 versus 480 NCF). Comparing the results among the different groups, K3 XF (either sterilized or not) showed a mean NCF significantly higher than all other files (P < .05). Repeated cycles of autoclave sterilization do not seem to influence the mechanical properties of NiTi endodontic instruments except for the K3 XF prototypes of rotary instruments that demonstrated a significant increase of cyclic fatigue resistance. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Transcriptomic Analysis Reveals Mechanisms of Sterile and Fertile Flower Differentiation and Development in Viburnum macrocephalum f. keteleeri

    PubMed Central

    Lu, Zhaogeng; Xu, Jing; Li, Weixing; Zhang, Li; Cui, Jiawen; He, Qingsong; Wang, Li; Jin, Biao

    2017-01-01

    Sterile and fertile flowers are an important evolutionary developmental (evo-devo) phenotype in angiosperm flowers, playing important roles in pollinator attraction and sexual reproductive success. However, the gene regulatory mechanisms underlying fertile and sterile flower differentiation and development remain largely unknown. Viburnum macrocephalum f. keteleeri, which possesses fertile and sterile flowers in a single inflorescence, is a useful candidate species for investigating the regulatory networks in differentiation and development. We developed a de novo-assembled flower reference transcriptome. Using RNA sequencing (RNA-seq), we compared the expression patterns of fertile and sterile flowers isolated from the same inflorescence over its rapid developmental stages. The flower reference transcriptome consisted of 105,683 non-redundant transcripts, of which 5,675 transcripts showed significant differential expression between fertile and sterile flowers. Combined with morphological and cytological changes between fertile and sterile flowers, we identified expression changes of many genes potentially involved in reproductive processes, phytohormone signaling, and cell proliferation and expansion using RNA-seq and qRT-PCR. In particular, many transcription factors (TFs), including MADS-box family members and ABCDE-class genes, were identified, and expression changes in TFs involved in multiple functions were analyzed and highlighted to determine their roles in regulating fertile and sterile flower differentiation and development. Our large-scale transcriptional analysis of fertile and sterile flowers revealed the dynamics of transcriptional networks and potentially key components in regulating differentiation and development of fertile and sterile flowers in Viburnum macrocephalum f. keteleeri. Our data provide a useful resource for Viburnum transcriptional research and offer insights into gene regulation of differentiation of diverse evo-devo processes in flowers. PMID:28298915

  3. Forced sterilization of women as discrimination.

    PubMed

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  4. Effects of gamma irradiation dose-rate on sterile male Aedesaegypti

    NASA Astrophysics Data System (ADS)

    Ernawan, Beni; Tambunan, Usman Sumo Friend; Sugoro, Irawan; Sasmita, Hadian Iman

    2017-06-01

    Aedesaegypti is the most important vector for dengue, yellow fever and Zika viruses. Considering its medical importance, vector population control program utilizing radiation-based sterile insect technique (SIT) is one of the potential methods for preventing and limiting the dispersal of these viruses. The present study was undertaken to evaluate the dose-rates effects of γ-sterilization on quality parameters of sterile males. Males Ae.aegypti at the pupal stage were sterilized by applying 70 Gyγ-rays in varies dose-rates, i.e. 0 (control), 300, 600, 900, 1200 and 1500Gy/h utilizing panoramic irradiator. Adult males that emerged from the pupal stage were assessed for their quality parameters, which are the percentage of emergence, longevity, sterility and mating competitiveness. The results herein indicate that there was no major effect of dose-rate on the percentage of emergence, the data showedthat there were no differences between irradiated males compared with control. Generally, the longevity of irradiated males was lower compared to control. The data also demonstrated that longevity was significantly increased at the dose-rate from 300 to 900Gy/h, then decreased at the dose-rate 900 to 1500 Gy/h. Sterility of irradiated maleswas significantly different compared to control, while there was no significantly different at dose rate 300 to 1500 Gy/h. Mating competitiveness of irradiated males was increased at the dose rate from 300 to 1200 Gy/h, then the value was decreased significantly at the dose rate 1500 Gy/h. The dose-rate effects of γ-sterilization were discussed in the context genetic vector control, in particular, the SIT. The results give information and contribute to better understanding towards γ-sterilization optimization and quality parameters of sterile male Ae. aegypti on SIT methods.

  5. Production of a sterile species via active-sterile mixing: An exactly solvable model

    NASA Astrophysics Data System (ADS)

    Boyanovsky, D.

    2007-11-01

    The production of a sterile species via active-sterile mixing in a thermal medium is studied in an exactly solvable model. The exact time evolution of the sterile distribution function is determined by the dispersion relations and damping rates Γ1,2 for the quasiparticle modes. These depend on γ˜=Γaa/2ΔE, with Γaa the interaction rate of the active species in absence of mixing and ΔE the oscillation frequency in the medium without damping. γ˜≪1, γ˜≫1 describe the weak and strong damping limits, respectively. For γ˜≪1, Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where θm is the mixing angle in the medium and the sterile distribution function does not obey a simple rate equation. For γ˜≫1, Γ1=Γaa and Γ2=Γaasin⁡22θm/4γ˜2, is the sterile production rate. In this regime sterile production is suppressed and the oscillation frequency vanishes at an Mikheyev-Smirnov-Wolfenstein (MSW) resonance, with a breakdown of adiabaticity. These are consequences of quantum Zeno suppression. For active neutrinos with standard model interactions the strong damping limit is only available near an MSW resonance if sin⁡2θ≪αw with θ the vacuum mixing angle. The full set of quantum kinetic equations for sterile production for arbitrary γ˜ are obtained from the quantum master equation. Cosmological resonant sterile neutrino production is quantum Zeno suppressed relieving potential uncertainties associated with the QCD phase transition.

  6. Sterilization of Persons with Mental Retardation.

    ERIC Educational Resources Information Center

    Elkins, Thomas E.; Andersen, H. Frank

    1992-01-01

    This article examines the historical, legal, and ethical concerns regarding sterilization for persons with mental retardation and offers guidelines to help counsel individuals with disabilities or their families regarding decision making about sterilization. (DB)

  7. Reversible Sterilization

    ERIC Educational Resources Information Center

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  8. The causes of genetic male sterility in 3 soybaen lines.

    PubMed

    Rubaihayo, P R; Gumisiriza, G

    1978-11-01

    The cause of male sterility in 3 soybean lines, TGM 103-1, N-69-2774 and TGM 242-4 was studied. In TGM 103-1, which was both male and female sterile, two different abnormalities were associated with sterility. Precocious movement of a few chromosomes at the metaphase I stage resulted into the production of non-functional pollen while cells which underwent apparent normal meiotic division had disintergration of the tapetal cell wall immediately after the free microspore stage leading to the starvation and subsequent death of the developing microspores. In lines N-69-2774 and TGM 242-4, both of which were partially sterile, male sterility resulted from a failure of cytokinesis after the telophase II stage. Meiosis proceeded normally but the 4 microspores after telophase II failed to separate into pollen grains and degenerated thereafter.

  9. Development and assessment of sterility of a closed-system pediatric peritoneal dialysis.

    PubMed

    Biazi, Ana Paula Pereira; Croti, Ulisses Alexandre; Braile, Domingo Marcolino; Oliveira, Marcos Aurélio Barboza de; Costa, Jane Gonçalves Soares; Cardoso, Lucas Monteiro

    2009-01-01

    To develop an easy-handling totally closed pediatric peritoneal dialysis system and assess the sterility assurance level. From February to December 2008 was designed and developed a closed-system pediatric peritoneal dialysis at the Bioengineering Division of Braile Biomédica Indústria, Comércio e Representações S/A. Twenty systems were manufactured and submitted to sterility assurance level testing, and were divided into Group A (10)--using the sterility test--and B (10)--ethylene oxide gas penetration. In Group A, the sterility test was negative for bacteria and fungi proliferation within 14 days in all systems. In Group B, the gas penetration test showed that there was gas penetration in all points assessed. It was possible to develop a new easy-handling closed-system pediatric peritoneal dialysis and ensure its sterility.

  10. Effect of Abiotic Factors on Degradation of Imidacloprid.

    PubMed

    Mahapatra, Bibhab; Adak, Totan; Patil, Naveen K B; Pandi, G Guru P; Gowda, G Basana; Yadav, Manoj Kumar; Mohapatra, S D; Rath, P C; Munda, Sushmita; Jena, Mayabini

    2017-10-01

    The role of soil moisture, light and pH on imidacloprid dissipation was investigated. A high performance liquid chromatography (HPLC) based method was developed to quantify imidacloprid present in soil with a recovery of more than 82%. Rate of dissipation of imidacloprid from soil was faster in submerged condition compared to field capacity and air dried condition. Imidacloprid dissipated non-significantly between sterile and non-sterile soils, but at field capacity, the dissipation was faster in non-sterile soil compared to sterile soil after 60 days of incubation. Similarly, under submergence, the dissipation of imidacloprid was 66.2% and 79.8% of the initial in sterile and non-sterile soils, respectively. Imidacloprid was rather stable in acidic and neutral water but was prone to photo-degradation. Therefore, imidacloprid degradation will be faster under direct sunlight and at higher soil moisture.

  11. Degradation of 316L stainless steel sternal wire by steam sterilization.

    PubMed

    Shih, Chun-Che; Su, Yea-Yang; Chen, Lung-Ching; Shih, Chun-Ming; Lin, Shing-Jong

    2010-06-01

    Sterilization is an important step prior to the implantation of medical devices inside the human body. In this work we studied the influence of steam sterilization cycles on the oxide film properties of stainless steel sternal wire. Characterization techniques such as open- circuit potential, potentiodynamic measurement, electrochemical impedance spectroscopy, cathodic stripping, transmission electron microscopy, atomic force microscopy and scanning electron microscopy were employed to investigate the cycles of steam sterilization on the corrosion behavior of sternal wire. The results showed that the oxide properties are a function of the number of steam sterilization cycles and deteriorate as the number of cycles increases. Steam sterilization might damage the implant integrity and heavy metals could be released to the surrounding tissues due to deterioration of the oxide film. Copyright 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. The context and limitations of female sterilization services in Pakistan.

    PubMed

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  13. Limited sterile processing capabilities for safe surgery in low-income and middle-income countries: experience in the Republic of Congo, Madagascar and Benin.

    PubMed

    Fast, Olive; Fast, Christina; Fast, Dan; Veltjens, Suzanne; Salami, Zouliha; White, Michelle C

    2017-01-01

    It is highly difficult to perform safe surgery without sterile instruments, yet the capacity to adequately clean, disinfect and sterilise surgical instruments in low-income and middle-income countries is largely unknown. Sterile Processing Education Charitable Trust developed an assessment tool and, in partnership with Mercy Ships, evaluated the sterile processing capacity in 59 facilities in Madagascar, Benin and the Republic of Congo. This data-driven analysis paper illustrates how lack of sterile processing capacity acts as a barrier to safe surgical care. Our tool identified widespread lack of knowledge of techniques and resources needed for sterile processing. Only 12% of workers in Republic of Congo and Benin had sterile processing training and none in Madagascar. None of the hospitals surveyed met basic standards for cleaning, disinfection and sterilisation as defined by the WHO/Pan American Health Organization. Examples of poor practice included lack of cleaning supplies (basic brushes and detergents), incorrect drying and storage of surgical instruments, and inattention to workflow causing cross-contamination. Bleach (sodium hypochlorite) solutions, damaging to instruments, were used universally. In our experience, using an assessment tool allowed identification of specific gaps in sterile processing capacity. Many of the gaps are amenable to simple solutions requiring minimal resources and achievable by most hospitals. We recommend that stakeholders seeking to strengthen surgical health systems in low-resource settings incorporate sterile processing capacity assessments and training into their programmes.

  14. Limited sterile processing capabilities for safe surgery in low-income and middle-income countries: experience in the Republic of Congo, Madagascar and Benin

    PubMed Central

    Fast, Olive; Fast, Christina; Fast, Dan; Veltjens, Suzanne; Salami, Zouliha

    2017-01-01

    It is highly difficult to perform safe surgery without sterile instruments, yet the capacity to adequately clean, disinfect and sterilise surgical instruments in low-income and middle-income countries is largely unknown. Sterile Processing Education Charitable Trust developed an assessment tool and, in partnership with Mercy Ships, evaluated the sterile processing capacity in 59 facilities in Madagascar, Benin and the Republic of Congo. This data-driven analysis paper illustrates how lack of sterile processing capacity acts as a barrier to safe surgical care. Our tool identified widespread lack of knowledge of techniques and resources needed for sterile processing. Only 12% of workers in Republic of Congo and Benin had sterile processing training and none in Madagascar. None of the hospitals surveyed met basic standards for cleaning, disinfection and sterilisation as defined by the WHO/Pan American Health Organization. Examples of poor practice included lack of cleaning supplies (basic brushes and detergents), incorrect drying and storage of surgical instruments, and inattention to workflow causing cross-contamination. Bleach (sodium hypochlorite) solutions, damaging to instruments, were used universally. In our experience, using an assessment tool allowed identification of specific gaps in sterile processing capacity. Many of the gaps are amenable to simple solutions requiring minimal resources and achievable by most hospitals. We recommend that stakeholders seeking to strengthen surgical health systems in low-resource settings incorporate sterile processing capacity assessments and training into their programmes. PMID:29225957

  15. Hybrid male sterility in rice is due to epistatic interactions with a pollen killer locus.

    PubMed

    Kubo, Takahiko; Yoshimura, Atsushi; Kurata, Nori

    2011-11-01

    In intraspecific crosses between cultivated rice (Oryza sativa) subspecies indica and japonica, the hybrid male sterility gene S24 causes the selective abortion of male gametes carrying the japonica allele (S24-j) via an allelic interaction in the heterozygous hybrids. In this study, we first examined whether male sterility is due solely to the single locus S24. An analysis of near-isogenic lines (NIL-F(1)) showed different phenotypes for S24 in different genetic backgrounds. The S24 heterozygote with the japonica genetic background showed male semisterility, but no sterility was found in heterozygotes with the indica background. This result indicates that S24 is regulated epistatically. A QTL analysis of a BC(2)F(1) population revealed a novel sterility locus that interacts with S24 and is found on rice chromosome 2. The locus was named Epistatic Factor for S24 (EFS). Further genetic analyses revealed that S24 causes male sterility when in combination with the homozygous japonica EFS allele (efs-j). The results suggest that efs-j is a recessive sporophytic allele, while the indica allele (EFS-i) can dominantly counteract the pollen sterility caused by S24 heterozygosity. In summary, our results demonstrate that an additional epistatic locus is an essential element in the hybrid sterility caused by allelic interaction at a single locus in rice. This finding provides a significant contribution to our understanding of the complex molecular mechanisms underlying hybrid sterility and microsporogenesis.

  16. Hybrid Male Sterility in Rice Is Due to Epistatic Interactions with a Pollen Killer Locus

    PubMed Central

    Kubo, Takahiko; Yoshimura, Atsushi; Kurata, Nori

    2011-01-01

    In intraspecific crosses between cultivated rice (Oryza sativa) subspecies indica and japonica, the hybrid male sterility gene S24 causes the selective abortion of male gametes carrying the japonica allele (S24-j) via an allelic interaction in the heterozygous hybrids. In this study, we first examined whether male sterility is due solely to the single locus S24. An analysis of near-isogenic lines (NIL-F1) showed different phenotypes for S24 in different genetic backgrounds. The S24 heterozygote with the japonica genetic background showed male semisterility, but no sterility was found in heterozygotes with the indica background. This result indicates that S24 is regulated epistatically. A QTL analysis of a BC2F1 population revealed a novel sterility locus that interacts with S24 and is found on rice chromosome 2. The locus was named Epistatic Factor for S24 (EFS). Further genetic analyses revealed that S24 causes male sterility when in combination with the homozygous japonica EFS allele (efs-j). The results suggest that efs-j is a recessive sporophytic allele, while the indica allele (EFS-i) can dominantly counteract the pollen sterility caused by S24 heterozygosity. In summary, our results demonstrate that an additional epistatic locus is an essential element in the hybrid sterility caused by allelic interaction at a single locus in rice. This finding provides a significant contribution to our understanding of the complex molecular mechanisms underlying hybrid sterility and microsporogenesis. PMID:21868603

  17. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Sterilization of Fusarium oxysporum by treatment of non-thermalequilibrium plasma in nutrient solution

    NASA Astrophysics Data System (ADS)

    Yasui, Shinji; Seki, Satoshi; Yoshida, Ryohei; Shoji, Kazuhiro; Terazoe, Hitoshi

    2016-01-01

    Fusarium wilt of spinach due to F. oxysporum infection is one of the most destructive root diseases in hydroponics in factories using the nutrient film technique. We investigated new technologies for the sterilization of microconidia of F. oxysporum by using a non-thermalequilibrium plasma treatment method in nutrient solution. Specifically, we investigated the sterilization capabilities of five types of gas (air, O2, N2, He, and Ar) used for plasma generation. The highest sterilization capability was achieved by using O2 plasma. However, ozone, which causes growth inhibition, was then generated and released into the atmosphere. The sterilization capability was lower when N2 or air plasma was used in the nutrient solution. It was confirmed that sterilization can be achieved by plasma treatment using inert gases that do not generate ozone; therefore, we determined that Ar plasma is the most preferable. In addition, we investigated the sterilization capabilities of other factors associated with Ar plasma generation, without direct plasma treatment. However, none of these other factors, which included Ar bubbling, pH reduction, increased temperature, hydrogen peroxide concentration, and UV radiation, could completely reproduce the results of direct plasma treatment. We assume that radicals such as O or OH may contribute significantly to the sterilization of microconidia of F. oxysporum in a nutrient solution.

  19. Overview of the application of nanosecond electron beams for radiochemical sterilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kotov, Y.A.; Sokovnin, S.Y.

    Problems concerning the use of nanosecond electron beams for sterilization of hermetically packed objects, and powdered or granulated materials, are discussed. The advantages and disadvantages of this type of radiation sterilization are demonstrated. The results are of interest to researchers who study the mechanism by which nanosecond electron beams act on microorganisms. It is worth considering repetitively pulsed electron accelerators as highly promising systems for use in commercial sterilization applications. Technologies and setups for the radiochemical sterilization (RCS) of medical glassware for blood products, beer bottles, bone meal used in food industry, medical instruments (surgical needles, systems for human kidneys),more » and of the external packaging for some biological materials used in ophthalmology are discussed. Such applications have been developed based on the use of the URT-0.2 and URT-0.5 repetitively nanosecond-pulsed electron accelerators. The observed sterilization of areas shaded from line-of-site irradiation and of the bottoms of, for example, glassware cannot be attributed to radiation sterilization alone, since the glass thickness was much larger than the range of electrons. Therefore, it can be conjectured that the demonstrated sterilization effect is due both to the electron beam and to the ozone and chemical radicals produced by the beam. Thus, one may introduce the notion of RCS.« less

  20. Dissecting the genetic architecture of F1 hybrid sterility in house mice.

    PubMed

    Dzur-Gejdosova, Maria; Simecek, Petr; Gregorova, Sona; Bhattacharyya, Tanmoy; Forejt, Jiri

    2012-11-01

    Hybrid sterility as a postzygotic reproductive isolation mechanism has been studied for over 80 years, yet the first identifications of hybrid sterility genes in Drosophila and mouse are quite recent. To study the genetic architecture of F(1) hybrid sterility between young subspecies of house mouse Mus m. domesticus and M. m. musculus, we conducted QTL analysis of a backcross between inbred strains representing these two subspecies and probed the role of individual chromosomes in hybrid sterility using the intersubspecific chromosome substitution strains. We provide direct evidence that the asymmetry in male infertility between reciprocal crosses is conferred by the middle region of M. m. musculus Chr X, thus excluding other potential candidates such as Y, imprinted genes, and mitochondrial DNA. QTL analysis identified strong hybrid sterility loci on Chr 17 and Chr X and predicted a set of interchangeable autosomal loci, a subset of which is sufficient to activate the Dobzhansky-Muller incompatibility of the strong loci. Overall, our results indicate the oligogenic nature of F(1) hybrid sterility, which should be amenable to reconstruction by proper combination of chromosome substitution strains. Such a prefabricated model system should help to uncover the gene networks and molecular mechanisms underlying hybrid sterility. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.

  1. The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature.

    PubMed

    Khabiri, Masoud; Ebrahimi, Maziar; Saei, Mohammad Reza

    2017-12-01

    File fracture can interfere with cleaning and shaping of the canal and compromise periradicular healing. Autoclave sterilization may prone the files to fracture. The purpose of the present study was to determine the effect of autoclave sterilization on the cyclic fatigue resistance of Hero642 rotary instrument in two curvatures of 45 and 60 degrees. For this experimental in-vitro study, 90 Nickel-Titanium HERO 642 rotary files #30 with 0.06 taper were selected. They were divided into two groups (curvature of 45 and 60 degree) of 45 files. Each group was then subdivided into 3 subgroups; group I: no sterilization, group II: 5 cycles of sterilization and group III: 10 cycles of sterilization. Files were used in artificial canals until fracture. The cyclic fatigue was measured as the number of cycles before fracture. The data was statically analyzed by Student's t-test and two-way analysis of variance. There was a significant difference in cyclic fatigue of two curvature of 45 and 60 degrees ( p = 0.001). However, sterilization process has no significant effect on cyclic fatigue of HERO files ( p = 0.557). Sterilization had no effect on the cyclic fatigue of HERO 642 files when used in curvature of 45 or 60 degrees.

  2. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    PubMed

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  3. Peracetic Acid: A Practical Agent for Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds

    PubMed Central

    Yoganarasimha, Suyog; Trahan, William R.; Best, Al M.; Bowlin, Gary L.; Kitten, Todd O.; Moon, Peter C.

    2014-01-01

    Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam, and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone, a low melting polymer, and employing spores of Bacillus atrophaeus as biological indicators, we compared ethylene oxide, autoclaving and 80% ethanol to a known chemical sterilant, peracetic acid (PAA), for their ability to sterilize as well as their effects on scaffold properties. PAA diluted in 20% ethanol to 1000 ppm or above sterilized electrospun scaffolds in 15 min at room temperature while maintaining nano-architecture and mechanical properties. Scaffolds treated with PAA at 5000 ppm were rendered hydrophilic, with contact angles reduced to 0°. Therefore, PAA can provide economical, rapid, and effective sterilization of heat-sensitive polymeric electrospun scaffolds that are used in tissue engineering. PMID:24341350

  4. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  5. Effects of sterilization treatments on the analysis of TOC in water samples.

    PubMed

    Shi, Yiming; Xu, Lingfeng; Gong, Dongqin; Lu, Jun

    2010-01-01

    Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants. However, the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments. Based on the principle of water total organic carbon (TOC) analysis, the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated. The results revealed that two conventional physical sterilization treatments, autoclaving and 60Co gamma-radiation sterilization, led to the direct decomposition of some organic pollutants, resulting in remarkable errors in the analysis of TOC in water samples. Furthermore, the extent of the errors varied with the intensity and the duration of sterilization treatments. Accordingly, a novel sterilization method for water samples, 0.45 microm micro-filtration coupled with ultraviolet radiation (MCUR), was developed in the present study. The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters. Before and after sterilization treatments, the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.

  6. Cytoplasmic male sterility in Mimulus hybrids has pleiotropic effects on corolla and pistil traits.

    PubMed

    Barr, C M; Fishman, L

    2011-05-01

    The mechanisms underlying genetic associations have important consequences for evolutionary outcomes, but distinguishing linkage from pleiotropy is often difficult. Here, we use a fine mapping approach to determine the genetic basis of association between cytonuclear male sterility and other floral traits in Mimulus hybrids. Previous work has shown that male sterility in hybrids between Mimulus guttatus and Mimulus nasutus is due to interactions between a mitochondrial gene from M. guttatus and two tightly linked nuclear restorer alleles on Linkage Group 7, and that male sterility is associated with reduced corolla size. In the present study, we generated a set of nearly isogenic lines segregating for the restorer region and male sterility, but with unique flanking introgressions. Male-sterile flowers had significantly smaller corollas, longer styles and greater stigmatic exsertion than fertile flowers. Because these effects were significant regardless of the genotypic composition of introgressions flanking the restorer region, they suggest that these floral differences are a direct byproduct of the genetic incompatibility causing anther abortion. In addition, we found a non-significant but intriguing trend for male-sterile plants to produce more seeds per flower than fertile siblings after supplemental pollination. Such pleiotropic effects may underlie the corolla dimorphism frequently observed in gynodioecious taxa and may affect selection on cytoplasmic male sterility genes when they initially arise.

  7. Garlic (Allium sativum L.) fertility: transcriptome and proteome analyses provide insight into flower and pollen development

    PubMed Central

    Shemesh-Mayer, Einat; Ben-Michael, Tomer; Rotem, Neta; Rabinowitch, Haim D.; Doron-Faigenboim, Adi; Kosmala, Arkadiusz; Perlikowski, Dawid; Sherman, Amir; Kamenetsky, Rina

    2015-01-01

    Commercial cultivars of garlic, a popular condiment, are sterile, making genetic studies and breeding of this plant challenging. However, recent fertility restoration has enabled advanced physiological and genetic research and hybridization in this important crop. Morphophysiological studies, combined with transcriptome and proteome analyses and quantitative PCR validation, enabled the identification of genes and specific processes involved in gametogenesis in fertile and male-sterile garlic genotypes. Both genotypes exhibit normal meiosis at early stages of anther development, but in the male-sterile plants, tapetal hypertrophy after microspore release leads to pollen degeneration. Transcriptome analysis and global gene-expression profiling showed that >16,000 genes are differentially expressed in the fertile vs. male-sterile developing flowers. Proteome analysis and quantitative comparison of 2D-gel protein maps revealed 36 significantly different protein spots, 9 of which were present only in the male-sterile genotype. Bioinformatic and quantitative PCR validation of 10 candidate genes exhibited significant expression differences between male-sterile and fertile flowers. A comparison of morphophysiological and molecular traits of fertile and male-sterile garlic flowers suggests that respiratory restrictions and/or non-regulated programmed cell death of the tapetum can lead to energy deficiency and consequent pollen abortion. Potential molecular markers for male fertility and sterility in garlic are proposed. PMID:25972879

  8. [Sterilization and eugenics].

    PubMed

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  9. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    PubMed

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  10. The Contribution of the Y Chromosome to Hybrid Male Sterility in House Mice

    PubMed Central

    Campbell, Polly; Good, Jeffrey M.; Dean, Matthew D.; Tucker, Priscilla K.; Nachman, Michael W.

    2012-01-01

    Hybrid sterility in the heterogametic sex is a common feature of speciation in animals. In house mice, the contribution of the Mus musculus musculus X chromosome to hybrid male sterility is large. It is not known, however, whether F1 male sterility is caused by X–Y or X-autosome incompatibilities or a combination of both. We investigated the contribution of the M. musculus domesticus Y chromosome to hybrid male sterility in a cross between wild-derived strains in which males with a M. m. musculus X chromosome and M. m. domesticus Y chromosome are partially sterile, while males from the reciprocal cross are reproductively normal. We used eight X introgression lines to combine different X chromosome genotypes with different Y chromosomes on an F1 autosomal background, and we measured a suite of male reproductive traits. Reproductive deficits were observed in most F1 males, regardless of Y chromosome genotype. Nonetheless, we found evidence for a negative interaction between the M. m. domesticus Y and an interval on the M. m. musculus X that resulted in abnormal sperm morphology. Therefore, although F1 male sterility appears to be caused mainly by X-autosome incompatibilities, X–Y incompatibilities contribute to some aspects of sterility. PMID:22595240

  11. A Complex Genetic Basis to X-Linked Hybrid Male Sterility Between Two Species of House Mice

    PubMed Central

    Good, Jeffrey M.; Dean, Matthew D.; Nachman, Michael W.

    2008-01-01

    The X chromosome plays a central role in the evolution of reproductive isolation, but few studies have examined the genetic basis of X-linked incompatibilities during the early stages of speciation. We report the results of a large experiment focused on the reciprocal introgression of the X chromosome between two species of house mice, Mus musculus and M. domesticus. Introgression of the M. musculus X chromosome into a wild-derived M. domesticus genetic background produced male-limited sterility, qualitatively consistent with previous experiments using classic inbred strains to represent M. domesticus. The genetic basis of sterility involved a minimum of four X-linked factors. The phenotypic effects of major sterility QTL were largely additive and resulted in complete sterility when combined. No sterility factors were uncovered on the M. domesticus X chromosome. Overall, these results revealed a complex and asymmetric genetic basis to X-linked hybrid male sterility during the early stages of speciation in mice. Combined with data from previous studies, we identify one relatively narrow interval on the M. musculus X chromosome involved in hybrid male sterility. Only a handful of spermatogenic genes are within this region, including one of the most rapidly evolving genes on the mouse X chromosome. PMID:18689897

  12. The contribution of the Y chromosome to hybrid male sterility in house mice.

    PubMed

    Campbell, Polly; Good, Jeffrey M; Dean, Matthew D; Tucker, Priscilla K; Nachman, Michael W

    2012-08-01

    Hybrid sterility in the heterogametic sex is a common feature of speciation in animals. In house mice, the contribution of the Mus musculus musculus X chromosome to hybrid male sterility is large. It is not known, however, whether F1 male sterility is caused by X-Y or X-autosome incompatibilities or a combination of both. We investigated the contribution of the M. musculus domesticus Y chromosome to hybrid male sterility in a cross between wild-derived strains in which males with a M. m. musculus X chromosome and M. m. domesticus Y chromosome are partially sterile, while males from the reciprocal cross are reproductively normal. We used eight X introgression lines to combine different X chromosome genotypes with different Y chromosomes on an F1 autosomal background, and we measured a suite of male reproductive traits. Reproductive deficits were observed in most F1 males, regardless of Y chromosome genotype. Nonetheless, we found evidence for a negative interaction between the M. m. domesticus Y and an interval on the M. m. musculus X that resulted in abnormal sperm morphology. Therefore, although F1 male sterility appears to be caused mainly by X-autosome incompatibilities, X-Y incompatibilities contribute to some aspects of sterility.

  13. A complex genetic basis to X-linked hybrid male sterility between two species of house mice.

    PubMed

    Good, Jeffrey M; Dean, Matthew D; Nachman, Michael W

    2008-08-01

    The X chromosome plays a central role in the evolution of reproductive isolation, but few studies have examined the genetic basis of X-linked incompatibilities during the early stages of speciation. We report the results of a large experiment focused on the reciprocal introgression of the X chromosome between two species of house mice, Mus musculus and M. domesticus. Introgression of the M. musculus X chromosome into a wild-derived M. domesticus genetic background produced male-limited sterility, qualitatively consistent with previous experiments using classic inbred strains to represent M. domesticus. The genetic basis of sterility involved a minimum of four X-linked factors. The phenotypic effects of major sterility QTL were largely additive and resulted in complete sterility when combined. No sterility factors were uncovered on the M. domesticus X chromosome. Overall, these results revealed a complex and asymmetric genetic basis to X-linked hybrid male sterility during the early stages of speciation in mice. Combined with data from previous studies, we identify one relatively narrow interval on the M. musculus X chromosome involved in hybrid male sterility. Only a handful of spermatogenic genes are within this region, including one of the most rapidly evolving genes on the mouse X chromosome.

  14. Pain Associated With Hysteroscopic Sterilization

    PubMed Central

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  15. An economic analysis of the benefits of sterilizing medical instruments in low-temperature systems instead of steam.

    PubMed

    McCreanor, Victoria; Graves, Nicholas

    2017-07-01

    Hydrogen peroxide-based, low-temperature sterilization has been shown to do less damage to medical instruments than steam autoclaves. However, low-temperature systems are more expensive to run. Higher costs need to be balanced against savings from reduced repair costs to determine value for money when choosing how to sterilize certain instruments, which are able to be reprocessed in either system. This analysis examines the economic effects of using low-temperature sterilization systems to reprocess rigid and semi-rigid endoscopes, which are sensitive to heat and moisture, but still able to be sterilized using steam. It examines the changes to costs and frequency of repairs expected over 10 years, resulting from a choice to sterilize these instruments in a low-temperature system instead of steam. Overall, the results showed that increased sterilization costs are outweighed by the savings associated with less frequent repairs. Over a 10-year period, in large health care facilities, the probability of achieving an internal rate of return of at least 6% is 0.81. Our model shows it is likely to be a good decision for large health care facilities to invest in low-temperature sterilization systems. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Limitations of Thioglycolate Broth as a Sterility Test Medium for Materials Exposed to Gaseous Ethylene Oxide1

    PubMed Central

    Doyle, John E.; Mehrhof, William H.; Ernst, Robert R.

    1968-01-01

    Although ethylene oxide is a reliable sterilizer, the process may be limited by diffusion. Thus, situations may exist where microorganisms are protected from the sterilizing gas. It is possible that the exterior of a substance may be sterilized, whereas the interior is not. We investigated three general types of materials in which this limitation of diffusion could occur: the bore of glass and plastic tubing, the center of cotton balls, and plastic adhesive film/paper backing interface. These materials were contaminated as close to their geometric center as possible with Bacillus subtilis var. niger spores occluded in crystals of sodium chloride. After exposure of the contaminated materials (except aluminum foil) to ethylene oxide, thioglycolate broth (a standard sterility-test medium) indicated sterility, whereas Trypticase Soy Broth indicated nonsterility. It is likewise possible that aerobic microorganisms, surviving in or on material after exposure to dry heat or steam sterilization processes, would not be recovered by thioglycollate broth. Entrapped aerobic organisms will probably not grow out in the low oxygen tension zone of an anaerobic medium such as thioglycollate broth. It is recommended than an aerobic medium such as Trypticase Soy Broth be used concurrently with thioglycolate broth for sterility testing. PMID:4973064

  17. Sterilization of space hardware.

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  18. Investigation of methods for sterilization of potting compounds and mated surfaces

    NASA Technical Reports Server (NTRS)

    Tulius, J. J.; Daley, D. J.; Phillips, G. B.

    1972-01-01

    The feasibility of using formaldehyde-liberating synthetic resins or polymers for the sterilization of potting compounds, mated and occluded areas, and spacecraft surfaces was demonstrated. The detailed study of interrelated parameters of formaldehyde gas sterilization revealed that efficient cycle conditions can be developed for the sterilization of spacecraft components. It was determined that certain parameters were more important than others in the development of cycles for specific applications. The use of formaldehyde gas for the sterilization of spacecraft components provides NASA with a highly efficient method which is inexpensive, reproducible, easily quantitated, materials compatible, operationally simple, generally non-hazardous and not thermally destructive.

  19. Reduction of antigenic protein levels in latex gloves after gamma irradiation.

    PubMed

    Zehr, B D; Gromelski, S; Beezhold, D

    1994-01-01

    Gamma irradiation is currently the method most commonly used to sterilize surgical gloves. In this study, the effect of gamma irradiation on antigenic proteins in latex gloves was examined. Protein extraction and quantitation were carried out using latex gloves before and after sterilization. Antigenic protein levels were determined by an ELISA assay specific for latex proteins (LEAP). LEAP analysis revealed a significant decrease after gamma-irradiation sterilization. This observation may partially explain the lower levels of extractable antigenic proteins found in sterile surgical gloves compared with nonsterile examination gloves. However, gamma irradiation was less effective than autoclave sterilization in reducing protein levels.

  20. Sterilization surgery - making a decision

    MedlinePlus

    ... medlineplus.gov/ency/article/002138.htm Sterilization surgery - making a decision To use the sharing features on this page, ... about all the options available to you before making the decision to have a sterilization procedure. Alternative Names Deciding ...

  1. Analysis of pain and satisfaction with office-based hysteroscopic sterilization.

    PubMed

    Levie, Mark; Weiss, Gil; Kaiser, Bente; Daif, Jennifer; Chudnoff, Scott G

    2010-09-01

    To assess pain and patient satisfaction with office-based hysteroscopic sterilization. This prospective, observational study was designed to assess patient pain perception and satisfaction with office-based hysteroscopic sterilization using the Essure device (Conceptus, Mountain View, CA). Faculty practice office at an inner-city urban medical center. Women seeking hysteroscopic sterilization. Office hysteroscopic sterilization under local anesthesia. Pain assessed at the time of the procedure by a 0-10 visual scale and satisfaction by a 1-5 scale. From June 2003 to June 2006, 209 patients were recruited. The mean scores for average procedural pain, most procedural pain, and average menstrual pain were 2.6+/-2.1, 3.3+/-2.5, and 3.6+/-2.6, respectively. Standardized pain scores revealed that 149 subjects (70%) experienced average pain that was less than or equal to the pain experienced with their menses. Mean satisfaction rating for the procedure was 4.7+/-0.71. Office-based hysteroscopic sterilization performed with local anesthesia alone is well tolerated, and patients are satisfied with this method for permanent sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Toxic effect of ethylene-oxide-sterilized freeze-dried bone allograft on human gingival fibroblasts.

    PubMed

    Kudryk, V L; Scheidt, M J; McQuade, M J; Sutherland, D E; VanDyke, T E; Hollinger, J O

    1992-11-01

    Freeze-dried bone allograft (FDBA) which either had or had not been sterilized by exposure to ethylene oxide (EtO) prior to lyophilization was obtained from two commercial sources. EtO-sterilized FDBA was reexposed to EtO as a positive control. Gas chromatograph assays revealed that three out of four commercially obtained EtO sterilized FDBA had no detectable EtO, with one sample having 0.21 parts per million (PPM). Surprisingly, 0.24 PPM was detected in one sample which had not been sterilized with EtO gas. This was presumed due to contamination from a gas-sterilized rubber stopper. In the cell toxicity study, FDBA and human gingival fibroblasts (HGF) were added simultaneously, incubated for 72 h, and fixed and stained. Samples of FDBA sterilized with EtO which were free of EtO did not alter HGF growth. However, the positive control FDBA which contained 0.72 PPM EtO had a deleterious effect on HGF. FDBA with EtO residuals caused morphologic change in HGF.

  3. Involuntary sterilization among HIV-positive Garifuna women from Honduras seeking asylum in the United States: Two case reports.

    PubMed

    Atkinson, Holly G; Ottenheimer, Deborah

    2018-05-01

    Voluntary sterilization is one of the most widely used forms of contraception by women worldwide; however, involuntary sterilization is considered a violation of multiple human rights and grounds for asylum in the United States. Women have been disproportionately affected by this practice. We report two cases of involuntary sterilization in HIV-positive Garifuna women from Honduras who sought asylum in America and were medically evaluated at the request of their attorneys. Key lessons can be drawn from these cases with regard to the importance of medical evaluations in establishing persecution. These include the need for a detailed account of the events surrounding sterilization, radiologic proof of tubal blockage if at all possible, and confirmation of significant and enduring mental distress as a result of the involuntary sterilization. Immigration attorneys and medical evaluators need to be attuned to the possibility of a history of involuntary sterilization among at risk women seeking asylum in the United States. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Search for sterile neutrino oscillations in muon neutrino disappearance at MINOS/MINOS+

    NASA Astrophysics Data System (ADS)

    Todd, Jacob; Minos+ Collaboration

    2017-01-01

    A wide variety of neutrino oscillation phenomena are well-described by the standard three-flavour neutrino model, but some anomalies exist. The LSND and MiniBooNE experiments have measured electron antineutrino appearance in excess of standard oscillation predictions, which points to the possibility of a sterile neutrino with higher mass than the presently known states. MINOS, a two-detector, long-baseline neutrino oscillation experiment, was optimized for the measurement of muon neutrino disappearance in the NuMI neutrino beam. A sterile neutrino responsible for the LSND and MiniBooNE excesses would cause distortions in the charged current and neutral current MINOS spectra, which permits the search for sterile neutrinos at MINOS. In close collaboration with the Daya Bay reactor neutrino experiment, MINOS has placed strong constraints on the sterile neutrino parameter space for a model with one additional sterile neutrino. Further, the extension of data collection with MINOS+, which samples the NuMI beam in a medium energy configuration, markedly increases the sensitivity of the combined MINOS and MINOS+ sample to a 3+1-flavour sterile neutrino model.

  5. Simple Y-autosomal incompatibilities cause hybrid male sterility in reciprocal crosses between Drosophila virilis and D. americana.

    PubMed

    Sweigart, Andrea L

    2010-03-01

    Postzygotic reproductive isolation evolves when hybrid incompatibilities accumulate between diverging populations. Here, I examine the genetic basis of hybrid male sterility between two species of Drosophila, Drosophila virilis and D. americana. From these analyses, I reach several conclusions. First, neither species carries any autosomal dominant hybrid male sterility alleles: reciprocal F(1) hybrid males are perfectly fertile. Second, later generation (backcross and F(2)) hybrid male sterility between D. virilis and D. americana is not polygenic. In fact, I identified only three genetically independent incompatibilities that cause hybrid male sterility. Remarkably, each of these incompatibilities involves the Y chromosome. In one direction of the cross, the D. americana Y is incompatible with recessive D. virilis alleles at loci on chromosomes 2 and 5. In the other direction, the D. virilis Y chromosome causes hybrid male sterility in combination with recessive D. americana alleles at a single QTL on chromosome 5. Finally, in contrast with findings from other Drosophila species pairs, the X chromosome has only a modest effect on hybrid male sterility between D. virilis and D. americana.

  6. Simple Y-Autosomal Incompatibilities Cause Hybrid Male Sterility in Reciprocal Crosses Between Drosophila virilis and D. americana

    PubMed Central

    Sweigart, Andrea L.

    2010-01-01

    Postzygotic reproductive isolation evolves when hybrid incompatibilities accumulate between diverging populations. Here, I examine the genetic basis of hybrid male sterility between two species of Drosophila, Drosophila virilis and D. americana. From these analyses, I reach several conclusions. First, neither species carries any autosomal dominant hybrid male sterility alleles: reciprocal F1 hybrid males are perfectly fertile. Second, later generation (backcross and F2) hybrid male sterility between D. virilis and D. americana is not polygenic. In fact, I identified only three genetically independent incompatibilities that cause hybrid male sterility. Remarkably, each of these incompatibilities involves the Y chromosome. In one direction of the cross, the D. americana Y is incompatible with recessive D. virilis alleles at loci on chromosomes 2 and 5. In the other direction, the D. virilis Y chromosome causes hybrid male sterility in combination with recessive D. americana alleles at a single QTL on chromosome 5. Finally, in contrast with findings from other Drosophila species pairs, the X chromosome has only a modest effect on hybrid male sterility between D. virilis and D. americana. PMID:20048051

  7. Sterile Neutrino Search in the NOvA Far Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edayath, Sijith; Aurisano, Adam; Sousa, Alexandre

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvementsmore » that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.« less

  8. Surgical sterilization: an underutilized procedure for evaluating the merits of induced sterility

    USGS Publications Warehouse

    Kennelly, James J.; Converse, Kathryn A.

    1993-01-01

    Despite more than 4 decades of effort, development of effective wildlife damage control programs based on sterilization of target species has met with limited success. This is partly due to the fact that investigators have assumed, rather than empirically tested, whether the reproductive strategies of the target populations were vulnerable to the planned treatment. Equally important, methods selected to include sterility usually involve a chemical agent that can affect sociosexual behaviors of the nuisance population. In this report, we illustrate how surgically induced sterility circumvents both problems--how the concept without the potentially confounding secondary effects of a chemical. We assessed the merits of initiating research to develop a male chemosterilant for Norway rats, red-winged blackbirds, beaver, and Canada geese by inducing sterility surgically. The infidelity of many red-winged females to their polygynous territorial male was surprising and argued against searching for a male sterilant. On the other hand, beaver and Canada goose studies confirmed previous reports that both form par-bonds and are monogamous. Both should be vulnerable to a male chemosterilant approach, and research toward this goal is justified.

  9. The not-so-sterile 4th neutrino: constraints on new gauge interactions from neutrino oscillation experiments

    NASA Astrophysics Data System (ADS)

    Kopp, Joachim; Welter, Johannes

    2014-12-01

    Sterile neutrino models with new gauge interactions in the sterile sector are phenomenologically interesting since they can lead to novel effects in neutrino oscillation experiments, in cosmology and in dark matter detectors, possibly even explaining some of the observed anomalies in these experiments. Here, we use data from neutrino oscillation experiments, in particular from MiniBooNE, MINOS and solar neutrino experiments, to constrain such models. We focus in particular on the case where the sterile sector gauge boson A ' couples also to Standard Model particles (for instance to the baryon number current) and thus induces a large Mikheyev-Smirnov-Wolfenstein potential. For eV-scale sterile neutrinos, we obtain strong constraints especially from MINOS, which restricts the strength of the new interaction to be less than ˜ 10 times that of the Standard Model weak interaction unless active-sterile neutrino mixing is very small (sin2 θ 24 ≲ 10-3). This rules out gauge forces large enough to affect short-baseline experiments like MiniBooNE and it imposes nontrivial constraints on signals from sterile neutrino scattering in dark matter experiments.

  10. Differences in the Access to Sterilization between Women Living and Not Living with HIV: Results from the GENIH Study, Brazil.

    PubMed

    Barbosa, Regina Maria; Cabral, Cristiane da Silva; do Lago, Tania di Giacomo; Pinho, Adriana de Araujo

    2016-01-01

    In many countries, young women of reproductive age have been especially affected by the HIV epidemic, which have fostered research to better understand how HIV infection influences and shapes women´s fertility and reproductive and sexual decisions. In Brazil, few studies have focused on the impact of the HIV epidemic on contraceptive choices among women living with HIV (WLHIV). This study evaluates the impact HIV infection may have in the access to female sterilization in Brazil, using a time-to-event analysis. A cross-sectional quantitative study (GENIH study) was conducted between February 2013 and April 2014 in the city of São Paulo, comparing two probabilistic samples of 975 WLHIV and 1,003 women not living with HIV (WNLHIV) aged 18 to 49. Sexual and reproductive data was collected retrospectively in order to reconstruct women's reproductive trajectories. Given the objectives of this study, the analysis was restricted to women with parity one or more and, in case of WLHIV, to those sterilized after HIV diagnosis and not infected through vertical transmission. The final sample analysis included 683 WNLHIV and 690 WLHIV. A series of multivariable-adjusted Cox models estimated the probability of being sterilized after HIV diagnosis, compared with WNLHIV. Models were adjusted for schooling, race/color, and stratified by parity at last delivery (1-2, 3+). Hazard ratios were calculated for female sterilization, and separately for interval and postpartum procedures (performed in conjunction with caesarean section or immediately after vaginal delivery). Additionally, information regarding unmet demand for female sterilization was also explored. No statistical difference in the overall risk of sterilization between WLHIV and WNLHIV in the two parity-related groups is observed: HR = 0.88 (0.54-1.43) and 0.94 (0.69-1.29), respectively, among women with 1-2 children and those with three and more. However, significant differences regarding the impact of HIV infection at sterilization are observed depending on the timing and the type of sterilization procedure. The probability of obtaining an interval sterilization is significantly lower for WLHIV compared to those not living with HIV. The reverse occurs regarding postpartum sterilization. Although sterilization is mainly performed in conjunction with caesarean section in Brazil, it is evident that caesarean sections are not the sole factor increasing the risk of sterilization among WLHIV. The results indicate barriers in the access to services offering interval sterilization for WLHIV and certain facilitation in obtaining the procedure in conjunction with caesarean section. Health policy makers at local and national levels should promote institutional changes in order to facilitate access to interval sterilization and to confront the sensitive discussion of WLHIV's eligibility for postpartum sterilization. It is also urgent to increase access to a wider range of contraceptive methods for WLHIV and promote dual method protection strategies. Moreover, since condom use may decrease in the future in the context of the preventive effect of antiretroviral therapy, promoting dual methods will expand the choices regarding the reproductive rights of women living with HIV.

  11. Differences in the Access to Sterilization between Women Living and Not Living with HIV: Results from the GENIH Study, Brazil

    PubMed Central

    Cabral, Cristiane da Silva; do Lago, Tania di Giacomo; Pinho, Adriana de Araujo

    2016-01-01

    Background In many countries, young women of reproductive age have been especially affected by the HIV epidemic, which have fostered research to better understand how HIV infection influences and shapes women´s fertility and reproductive and sexual decisions. In Brazil, few studies have focused on the impact of the HIV epidemic on contraceptive choices among women living with HIV (WLHIV). Objective This study evaluates the impact HIV infection may have in the access to female sterilization in Brazil, using a time-to-event analysis. Methods A cross-sectional quantitative study (GENIH study) was conducted between February 2013 and April 2014 in the city of São Paulo, comparing two probabilistic samples of 975 WLHIV and 1,003 women not living with HIV (WNLHIV) aged 18 to 49. Sexual and reproductive data was collected retrospectively in order to reconstruct women's reproductive trajectories. Given the objectives of this study, the analysis was restricted to women with parity one or more and, in case of WLHIV, to those sterilized after HIV diagnosis and not infected through vertical transmission. The final sample analysis included 683 WNLHIV and 690 WLHIV. A series of multivariable-adjusted Cox models estimated the probability of being sterilized after HIV diagnosis, compared with WNLHIV. Models were adjusted for schooling, race/color, and stratified by parity at last delivery (1–2, 3+). Hazard ratios were calculated for female sterilization, and separately for interval and postpartum procedures (performed in conjunction with caesarean section or immediately after vaginal delivery). Additionally, information regarding unmet demand for female sterilization was also explored. Findings No statistical difference in the overall risk of sterilization between WLHIV and WNLHIV in the two parity-related groups is observed: HR = 0.88 (0.54–1.43) and 0.94 (0.69–1.29), respectively, among women with 1–2 children and those with three and more. However, significant differences regarding the impact of HIV infection at sterilization are observed depending on the timing and the type of sterilization procedure. The probability of obtaining an interval sterilization is significantly lower for WLHIV compared to those not living with HIV. The reverse occurs regarding postpartum sterilization. Although sterilization is mainly performed in conjunction with caesarean section in Brazil, it is evident that caesarean sections are not the sole factor increasing the risk of sterilization among WLHIV. Conclusion The results indicate barriers in the access to services offering interval sterilization for WLHIV and certain facilitation in obtaining the procedure in conjunction with caesarean section. Health policy makers at local and national levels should promote institutional changes in order to facilitate access to interval sterilization and to confront the sensitive discussion of WLHIV’s eligibility for postpartum sterilization. It is also urgent to increase access to a wider range of contraceptive methods for WLHIV and promote dual method protection strategies. Moreover, since condom use may decrease in the future in the context of the preventive effect of antiretroviral therapy, promoting dual methods will expand the choices regarding the reproductive rights of women living with HIV. PMID:27812146

  12. Sterility Testing of Prototype Plastic Aseptic Docking Tubes

    DTIC Science & Technology

    1982-09-01

    Bacillus stearothermophilus CL21. AmerRACT (Coat~e- aeids uIf 8" niev teIi by block n"Unbee) Fifty-nine pairs of sterile docking tabs, manufactured...of Bacillus stearothermophilus , _J sealed, and flushed with sterile culture medium. Twenty five percent of the LA_.. seals failed because of...were similarly attached to sterile tubes of Becton Dickenson supplemented peptone broth. A 25 ul aliquot of Bacillus stearothermophilus spores (Ix]O

  13. Electrochemically Based Modules for Sterilization in the Field. Phase 2.

    DTIC Science & Technology

    1995-09-30

    NO: DAMD 17-91-C-1105 TITLE: Electrochemically Based Modules for Sterilization in the Field PRINCIPAL INVESTIGATOR(S) : G. Duncan Hitchens, Ph.D. Tom...NUMBERS Electrochemically Based Modules for Sterilization in the Field 6. AUTHOR(S) DAMD17-91-C-1105 G. Duncan Hitchens, Ph.D. Tom C. Allen, Tom D. Rogers...of high concentration ozone as an alternative to ethylene oxide for use in medical sterilization systems. Evaluations of high concentration

  14. A NEW AUTOCLAVE SYSTEM FOR STERILIZING VITAMIN-FORTIFIED, COMMERCIAL RODENT DIETS WITH LOWER NUTRIENT LOSS.

    DTIC Science & Technology

    would (a) require less time and (b) not destroy vitamins. Feed contaminated with Bacillus stearothermophilus and B. subtilis was sterilized in high...The study was designed to develop a method for sterilizing vitamin-fortified commercial diets for feeding germ-free and defined-flora rodents that...high-prevacuum autoclaves makes possible a reduction in the time required to sterilize autoclavable, commercial diets. Previous methods have required

  15. On the intrinsic sterility of 3D printing

    PubMed Central

    Flynn, Kaitlin J.; Zaman, Luis; Tung, Emily; Pudlo, Nicholas

    2016-01-01

    3D printers that build objects using extruded thermoplastic are quickly becoming commonplace tools in laboratories. We demonstrate that with appropriate handling, these devices are capable of producing sterile components from a non-sterile feedstock of thermoplastic without any treatment after fabrication. The fabrication process itself results in sterilization of the material. The resulting 3D printed components are suitable for a wide variety of applications, including experiments with bacteria and cell culture. PMID:27920950

  16. Sterility method of pest control and its potential role in an integrated sea lamprey (Petromyzon marinus) control program

    USGS Publications Warehouse

    Hanson, Lee H.; Manion, Patrick J.

    1980-01-01

    The sterility method of pest control could be an effective tool in the sea lamprey (Petromyzon marinus) control program in the Great Lakes. Some of the requirements for its successful application have been met. A field study demonstrated that the release of male sea lampreys, sterilized by the injection of 100 mg/kg of P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir), will reduce the number of viable larvae produced. The actual reduction in reproductive success that occurred was directly related to the ratio of sterile to normal males in the population. The technique can be used in many ways in an integrated control program and has considerable potential for the more effective control of the sea lamprey. Eradication is a distinct possibility.Key words: sea lamprey, Petromyzon marinus; pest control, fish control, sterile-male technique, sterilization, chemosterilants, bisazir, Great Lakes

  17. Research to support sterile-male-release and genetic alteration techniques for sea lamprey control

    USGS Publications Warehouse

    Bergstedt, Roger A.; Twohey, Michael B.

    2007-01-01

    Integrated pest management of sea lampreys in the Laurentian Great Lakes has recently been enhanced by addition of a sterile-male-release program, and future developments in genetic approaches may lead to additional methods for reducing sea lamprey reproduction. We review the development, implementation, and evaluation of the sterile-male-release technique (SMRT) as it is being applied against sea lampreys in the Great Lakes, review the current understanding of SMRT efficacy, and identify additional research areas and topics that would increase either the efficacy of the SMRT or expand its geographic potential for application. Key areas for additional research are in the sterilization process, effects of skewed sex ratios on mating behavior, enhancing attractiveness of sterilized males, techniques for genetic alteration of sea lampreys, and sources of animals to enhance or expand the use of sterile lampreys.

  18. Viking heat sterilization - Progress and problems

    NASA Technical Reports Server (NTRS)

    Daspit, L. P.; Cortright, E. M.; Stern, J. A.

    1974-01-01

    The Viking Mars landers to be launched in 1975 will carry experiments in biology, planetology, and atmospheric physics. A terminal dry-heat sterilization process using an inert gas was chosen to meet planetary quarantine requirements and preclude contamination of the biology experiment by terrestrial organisms. Deep sterilization is performed at the component level and terminal surface sterilization at the system level. Solutions to certain component problems relating to sterilization are discussed, involving the gyroscope, tape recorder, battery, electronic circuitry, and outgassing. Heat treatment placed special requirements on electronic packaging, including fastener preload monitoring and solder joints. Chemical and physical testing of nonmetallic materials was performed to establish data on their behavior in heat-treatment and vacuum environments. A Thermal Effects Test Model and a Proof Test Capsule were used. It is concluded that a space vehicle can be designed and fabricated to withstand heat sterilization requirements.

  19. Post-sterilization autonomy among young mothers in South India.

    PubMed

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  20. FREE RADICALS IN THERMALLY STERILIZED ACIDUM BORICUM AND OPTIMIZATION OF THIS PROCESS.

    PubMed

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Free radicals formation in the acidum boricum (AB) during thermal sterilization process was examined by an X-band (9.3 GHz) electron paramagnetic resonance (EPR) spectroscopy. Acidum boricum was sterilized according to the pharmacopea norms at temperatures 160°C (120 min), 170°C (60 min), and 180°C (30 min). Free radicals (~10(17) spin/g) were thermally formed in these drug. The free radicals system revealed complex character, and the asymmetrical EPR spectra were measured. Mainly oxygen free radicals exist in the tested heated AB. Slower spin-lattice relaxation processes exist in AB sterilized at 160, 170 and 180°C. AB may be sterilized at temperatures 160, 170 and 180°C. For AB thermal sterilization at temperature 170°C is recommended. Free radicals concentrations changes during storage of the examined AB, and probably interactions with oxygen molecules may be responsible for this effect.

  1. Control and constraint for low-income women choosing outpatient sterilization.

    PubMed

    Leyser-Whalen, Ophra; Berenson, Abbey B

    2013-08-01

    Little is known about Hispanics and their contraceptive choices in general, with some past studies detailing nonconsensual sterilization. This article is based on interviews with a mostly Hispanic sample of 44 women being sterilized at a public clinic in southeast Texas with the Essure device, which entails a new outpatient sterilization procedure. The women cited relationship factors, wanting to better their and their children's lives, and past reproductive histories as reasons for deciding on sterilization. They specifically chose Essure as a result of an apprehension of surgery and potential side effects from tubal ligation. Their choices, however, were limited by larger structural factors of work, family, the political economy, and the health care system. We concluded that this new sterilization technique provided more contraceptive choices for these women, yet more contraceptive decision-making autonomy and more equitable social structures are still needed.

  2. Pest persistence and eradication conditions in a deterministic model for sterile insect release.

    PubMed

    Gordillo, Luis F

    2015-01-01

    The release of sterile insects is an environment friendly pest control method used in integrated pest management programmes. Difference or differential equations based on Knipling's model often provide satisfactory qualitative descriptions of pest populations subject to sterile release at relatively high densities with large mating encounter rates, but fail otherwise. In this paper, I derive and explore numerically deterministic population models that include sterile release together with scarce mating encounters in the particular case of species with long lifespan and multiple matings. The differential equations account separately the effects of mating failure due to sterile male release and the frequency of mating encounters. When insects spatial spread is incorporated through diffusion terms, computations reveal the possibility of steady pest persistence in finite size patches. In the presence of density dependence regulation, it is observed that sterile release might contribute to induce sudden suppression of the pest population.

  3. Thermalizing Sterile Neutrino Dark Matter

    NASA Astrophysics Data System (ADS)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  4. Lessons from the recent rise in use of female sterilization in Malawi.

    PubMed

    Jacobstein, Roy

    2013-03-01

    Although female sterilization is the most widely used modern contraceptive method in the world, most family planning programs in Africa have had difficulty providing it. Malawi, however, despite daunting constraints, has made female sterilization widely and equitably accessible, thereby increasing method choice and helping its citizens better meet their reproductive intentions. Ten percent of currently married Malawian women of reproductive age rely on female sterilization for contraceptive protection, compared with less than 2 percent across Africa, and demand to limit births now exceeds demand to space births. Malawi's female sterilization prevalence surpasses that of some high-resource countries. Key service-delivery factors enabling this achievement include supportive policies, strong public-private partnerships, and mobile services delivered at no cost by dedicated providers. Challenges remain, but Malawi's achievement offers lessons for other countries with low availability of female sterilization and similar resource constraints. © 2013 The Population Council, Inc.

  5. Control and Constraint for Low-Income Women Choosing Outpatient Sterilization

    PubMed Central

    Leyser-Whalen, Ophra; Berenson, Abbey B.

    2012-01-01

    Little is known about Hispanics and their contraceptive choices in general, with some past studies detailing non-consensual sterilization. This article is based on interviews with a mostly Hispanic sample of 44 women being sterilized at a public clinic in southeast Texas with the Essure device, which entails a new outpatient sterilization procedure. These women cited relationship factors, wanting to better their and their children’s lives, and past reproductive histories as reasons for deciding on sterilization. They specifically chose Essure as a result of an apprehension of surgery and potential side effects from tubal ligation. Their choices, however, were limited by larger structural factors of work, family, the political economy, and the health care system. We conclude that this new sterilization technique provided more contraceptive choices for these women, yet more contraceptive decision making autonomy, as well as more equitable social structures, are still needed. PMID:23761929

  6. Evaluation of a low-temperature steam and formaldehyde sterilizer.

    PubMed

    Kanemitsu, K; Kunishima, H; Imasaka, T; Ishikawa, S; Harigae, H; Yamato, S; Hirayama, Y; Kaku, M

    2003-09-01

    We evaluated a low-temperature steam and formaldehyde (LTSF) sterilizer based on the draft European Standard prEN 14180. Microbiological tests were conducted on small and full loads using process challenge devices in five programs (P1-P5). With small loads all tests showed no growth of Bacillus stearothermophilus (ATCC7953) spores. However, positive cultures were observed with full-load tests using P5 (sterilization temperature, 50 degrees C). Our data indicated that the load influenced the efficacy of the LTSF sterilizer. Desorption tests were conducted to determine residual formaldehyde in indicator strips. The mean concentrations of formaldehyde in P1-P5 were 31.9, 56.3, 54.9, 82.2 and 180.6 microg, respectively, which are below the limits allowed by the draft Standard. Our results indicate that the LTSF sterilizer is useful for sterilization because of its excellent efficacy, short handling time, and safety.

  7. Effects of humidity on sterilization of Geobacillus stearothermophilus spores with plasma-excited neutral gas

    NASA Astrophysics Data System (ADS)

    Matsui, Kei; Ikenaga, Noriaki; Sakudo, Noriyuki

    2015-06-01

    We investigate the effects of relative humidity on the sterilization process using a plasma-excited neutral gas that uniformly sterilizes both the space and inner wall of the reactor chamber at atmospheric pressure. Only reactive neutral species such as plasma-excited gas molecules and radicals were separated from the plasma and sent to the reactor chamber for chemical sterilization. The plasma source gas is nitrogen mixed with 0.1% oxygen, and the relative humidity in the source gas is controlled by changing the mixing ratio of water vapor. The relative humidity near the sample in the reactor chamber is controlled by changing the sample temperature. As a result, the relative humidity near the sample should be kept in the range from 60 to 90% for the sterilization of Geobacillus stearothermophilus spores. When the relative humidity in the source gas increases from 30 to 90%, the sterilization effect is enhanced by the same degree.

  8. Genetic basis to hybrid inviability is more complex than hybrid male sterility in Caenorhabditis nematodes.

    PubMed

    Bundus, Joanna D; Wang, Donglin; Cutter, Asher D

    2018-04-07

    Hybrid male sterility often evolves before female sterility or inviability of hybrids, implying that the accumulation of divergence between separated lineages should lead hybrid male sterility to have a more polygenic basis. However, experimental evidence is mixed. Here, we use the nematodes Caenorhabditis remanei and C. latens to characterize the underlying genetic basis of asymmetric hybrid male sterility and hybrid inviability. We demonstrate that hybrid male sterility is consistent with a simple genetic basis, involving a single X-autosome incompatibility. We also show that hybrid inviability involves more genomic compartments, involving diverse nuclear-nuclear incompatibilities, a mito-nuclear incompatibility, and maternal effects. These findings demonstrate that male sensitivity to genetic perturbation may be genetically simple compared to hybrid inviability in Caenorhabditis and motivates tests of generality for the genetic architecture of hybrid incompatibility across the breadth of phylogeny.

  9. Thermalizing Sterile Neutrino Dark Matter.

    PubMed

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  10. Sterilizing effects of cobalt-60 and cesium-137 radiation on male sea lampreys

    USGS Publications Warehouse

    Hanson, L.H.

    1990-01-01

    Male spawning-run sea lampreys Petromyzon marinus were exposed to various doses of cobalt-60 or cesium-137 radiation in an attempt to sterilize them for use in a program for controlling sea lampreys through the release of sterile males. Males captured and irradiated during the early part of the upstream migration were not effectively sterilized at the doses tested. After irradiation, the sea lampreys were more susceptible to fungal infections by Saprolegnia sp., and many died without attempting to spawn. Males captured and irradiated during the middle and late parts of the spawning migration were effectively sterilized at a dose of 2,000 rads. However, some radiation-induced mortality was observed in males captured and irradiated during the middle part of the spawning migration. Radiation is not as effective as the chemosterilant bisazir for sterilizing male sea lampreys.

  11. Sterilization: women fit to be tied.

    PubMed

    Caress, B

    1975-01-01

    Sterilization abuse is both systematic and widespread. Frequently, women are misled about the dangers of surgery, misinformed about its permanence, and coerced while under the stress of labor or abortion. Generally, instances of abuses in the health system are treated as illegitimate, illegal aberations of an otherwise decent health care system. Careful examination of these so called abuses would reveal that each can be causally connected to particular aspects of the care of America's health system. Sterilization abuse stems from a combination of factors inherent in the health system plus 1 critical additional factor. Besides resulting from teaching and research imperatives, profit making, and the fee for service systems, such abuse is the most widespread example of medicine as an instrument of social control. Sterilization is the most extreme form of birth control and birth control is official US government policy. There were about 500,000 sterilizations performed on American women in 1973. None of the sterilization methods is innocuous, and each is associated with some physical and psychological side effects. General agreement exists in the medical literature that some risk is attendant to each procedure. Sterilization is the most dangerous and the fastest growing method of birth control. Since 1970 the figures show an almost 3-fold increase in the incidence of female sterilization, from 192,000 in 1970 to 548,000 in 1974. Much evidence exists to suggest that the increase in the number of sterilizations has fueled a trend toward the sterilization of younger women with fewer children. Official accommodation to liberalization of sterilization practices in the US came in 1969, when the American College of Obstetricians and Gynecologists (ACOG) withdrew its age parity formula. This liberalization of sterilization guidelines opened the floodgates to abuse. Some of the increase in the number of operations performed is due to increased demand, some of it is the result of misinformation and coercion. Training imperatives and political attitudes account for some of the increase in hysterectomies. Many young gynecologists in training have united their professional needs for training and their political ideas. Another reason for an increase in operations is greed. Doctors' attitudes toward sterilization and the misinformation about its impact stem from the same source: a change in government attitude toward population control. Although budget tightening is the byword for most government financed health care at this time, this is not the case for contraceptive services. Between 1967 and 1973 federal support for family planning services increased more than 1300%, from $11 million to $149 million. The growth of US spending for its birth control program abroad has been just as spectacular. Providing birth control services is population control. The line between voluntary and involuntary sterilization becomes thinner all the time.

  12. Sterilization and its consequences.

    PubMed

    Hendrix, N W; Chauhan, S P; Morrison, J C

    1999-12-01

    The purpose of this review is to analyze critically the two techniques of sterilization (bilateral tubal ligation [BTL] and vasectomy) so that a physician may provide informed consent about methods of sterilization. A MEDLINE search and extensive review of published literature dating back to 1966 was undertaken to compare preoperative counseling, operative procedures, postoperative complications, procedure-related costs, psychosocial consequences, and feasibility of reversal between BTL and a vasectomy. Compared with a vasectomy, BTL is 20 times more likely to have major complications, 10 to 37 times more likely to fail, and cost three times as much. Moreover, the procedure-related mortality, although rare, is 12 times higher with sterilization of the woman than of the man. Despite these advantages, 300,000 more BTLs were done in 1987 than vasectomies. In 1987, there were 976,000 sterilizations (65 percent BTLs and 35 percent vasectomies) with an overall cost of $1.8 billion. Over $260 million could have been saved if equal numbers of vasectomies and BTLs had been performed, or more than $800 million if 80 percent had been vasectomies, as was the case in 1971. The safest, most efficacious, and least expensive method of sterilization is vasectomy. For these reasons, physicians should recommend vasectomy when providing counseling on sterilization, despite the popularity of BTL. Obstetricians & Gynecologists, Family Physicians After completion of this article, the reader will be able to predict the failure rates and likelihood of successful reversal of tubal ligation and vasectomy; to recall the difference in cost between the two sterilization procedures, and to describe the short-term and long-term complications associated with each of the two methods of sterilization.

  13. Manipulation of the microbiota of mass-reared Mediterranean fruit flies Ceratitis capitata (Diptera: Tephritidae) improves sterile male sexual performance.

    PubMed

    Ben Ami, Eyal; Yuval, Boaz; Jurkevitch, Edouard

    2010-01-01

    The sterile insect technique (SIT) is a method of biological control whereby millions of factory reared sterile male insects are released into the field. This technique is commonly used to combat the Mediterranean fruit fly (Ceratitis capitata, Diptera: Tephritidae). Sterile medfly males are less competent in attracting and mating with wild females, a property commonly linked to the irradiation process responsible for the sterilization. As bacteria are important partners in the fly's life cycle, we used molecular analytical methods to study the community structure of the gut microbiota in irradiated male medflies. We find that the sterilizing irradiation procedure affects the gut bacterial community structure of the Mediterranean fruit fly. Although the Enterobacteriaceae family remains the dominant bacterial group present in the gut, the levels of Klebsiella species decreases significantly in the days after sterilization. In addition, we detected substantial differences in some bacterial species between the mass rearing strain Vienna 8 and the wild strain. Most notable among these are the increased levels of the potentially pathogenic species Pseudomonas in the industrial strain. Testing the hypothesis that regenerating the original microbiota community could result in enhanced competitiveness of the sterile flies, we found that the addition of the bacterial species Klebsiella oxytoca to the postirradiation diet enables colonization of these bacteria in the gut while resulting in decreased levels of the Pseudomonas sp. Feeding on diets containing bacteria significantly improved sterile male performance in copulatory tests. Further studies will determine the feasibility of bacterial amelioration in SIT operations.

  14. Sterilization of Lung Matrices by Supercritical Carbon Dioxide

    PubMed Central

    Balestrini, Jenna L.; Liu, Angela; Gard, Ashley L.; Huie, Janet; Blatt, Kelly M.S.; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J.; Mecham, Robert P.; Wilcox, Elise C.

    2016-01-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10−6 in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes. PMID:26697757

  15. Prevalence and Clinical Significance of Sterile Intra-amniotic Inflammation in Patients with Preterm Labor and Intact Membranes

    PubMed Central

    Romero, Roberto; Miranda, Jezid; Chaiworapongsa, Tinnakorn; Korzeniewski, Steven J.; Chaemsaithong, Piya; Gotsch, Francesca; Dong, Zhong; Ahmed, Ahmed I.; Yoon, Bo Hyun; Hassan, Sonia S.; Kim, Chong J.; Yeo, Lami

    2014-01-01

    Problem Inflammation and infection play a major role in preterm birth. The purpose of this study was to: 1) determine the prevalence and clinical significance of sterile intra-amniotic inflammation; and 2) examine the relationship between amniotic fluid (AF) concentrations of high mobility group box-1 (HMGB1) and the interval from amniocentesis-to-delivery in patients with sterile intra-amniotic inflammation. Method of Study AF samples obtained from 135 women with preterm labor and intact membranes were analyzed using cultivation techniques as well as broad-range PCR and mass spectrometry (PCR/ESI-MS). Sterile intra-amniotic inflammation was defined when patients with negative AF cultures and without evidence of microbial footprints had intra-amniotic inflammation (AF interleukin-6 ≥ 2.6 ng/mL). Results 1) The frequency of sterile intra-amniotic inflammation was significantly greater than that of microbial-associated intra-amniotic inflammation [26% (35/135) vs. 11% (15/135); (p=0.005)]; 2) patients with sterile intra-amniotic inflammation delivered at comparable gestational ages, had similar rates of acute placental inflammation and adverse neonatal outcomes as patients with microbial-associated intra-amniotic inflammation; and 3) patients with sterile intra-amniotic inflammation and high AF concentrations of HMGB1 (≥ 8.55 ng/mL) delivered earlier than those with low AF concentrations of HMGB1 (p=0.02). Conclusions 1) sterile intra-amniotic inflammation is more frequent than microbial-associated intra-amniotic inflammation; and 2) we propose that danger signals participate in sterile intra-amniotic inflammation in the setting of preterm labor. PMID:25078709

  16. Comparative transcript profiling of the fertile and sterile flower buds of pol CMS in B. napus.

    PubMed

    An, Hong; Yang, Zonghui; Yi, Bin; Wen, Jing; Shen, Jinxiong; Tu, Jinxing; Ma, Chaozhi; Fu, Tingdong

    2014-04-03

    The Polima (pol) system of cytoplasmic male sterility (CMS) and its fertility restoration gene Rfp have been used in hybrid breeding in Brassica napus, which has greatly improved the yield of rapeseed. However, the mechanism of the male sterility transition in pol CMS remains to be determined. To investigate the transcriptome during the male sterility transition in pol CMS, a near-isogenic line (NIL) of pol CMS was constructed. The phenotypic features and sterility stage were confirmed by anatomical analysis. Subsequently, we compared the genomic expression profiles of fertile and sterile young flower buds by RNA-Seq. A total of 105,481,136 sequences were successfully obtained. These reads were assembled into 112,770 unigenes, which composed the transcriptome of the bud. Among these unigenes, 72,408 (64.21%) were annotated using public protein databases and classified into functional clusters. In addition, we investigated the changes in expression of the fertile and sterile buds; the RNA-seq data showed 1,148 unigenes had significantly different expression and they were mainly distributed in metabolic and protein synthesis pathways. Additionally, some unigenes controlling anther development were dramatically down-regulated in sterile buds. These results suggested that an energy deficiency caused by orf224/atp6 may inhibit a series of genes that regulate pollen development through nuclear-mitochondrial interaction. This results in the sterility of pol CMS by leading to the failure of sporogenous cell differentiation. This study may provide assistance for detailed molecular analysis and a better understanding of pol CMS in B. napus.

  17. Which is the best method of sterilization of tumour bone for reimplantation? a biomechanical and histopathological study

    PubMed Central

    2010-01-01

    Introduction Sterilization and re-usage of tumour bone for reconstruction after tumour resection is now gaining popularity in the East. This recycle tumour bone needs to be sterilized in order to eradicate the tumour cells before re-implantation for limb salvage procedures. The effect of some of these treatments on the integrity and sterility of the bone after treatment has been published but there has yet been a direct comparison between the various methods of sterilization to determine the one method that gives the best tumour kill without compromising the bone's structural integrity. Method This study was performed to evaluate the effect of several sterilization methods on the mechanical behavior of human cortical bone graft and histopathology evaluation of tumour bone samples after being processed with 4 different methods of sterilization. Fresh human cortical tumour bone is harvested from the diaphyseal region of the tumour bone were sterilized by autoclave (n =10); boiling (n =10); pasteurization (n =10); and irradiation (n =10). There were also 10 control specimens that did not receive any form of sterilization treatment. The biomechanical test conducted were stress to failure, modulus and strain to failure, which were determined from axial compression testing. Statistical analysis (ANOVA) was performed on these results. Significance level (α) and power (β) were set to 0.05 and 0.90, respectively. Results ANOVA analysis of 'failure stress', 'modulus' and 'strain to failure' demonstrated significant differences (p < 0.05) between treated cortical bone and untreated specimens under mechanical loading. 'Stress to failure' was significantly reduced in boiled, autoclaved and irradiated cortical bone samples (p < 0.05). 'Modulus' detected significant differences in the boiled, autoclaved and pasteurization specimens compared to controls (p < 0.05). 'Strain to failure' was reduced by irradiation (p < 0.05) but not by the other three methods of treatments. Histopathology study revealed no viable tumour cell in any of four types of treatment group compared to the untreated control group. Conclusions Sterilization of cortical bone sample by pasteurization and to a lesser extent, irradiation does not significantly alter the mechanical properties when compared with untreated samples. Mechanical properties degrade with the use of high temperature for sterilization (boiling). All methods of sterilization gave rise to 100 percent tumour kill. PMID:20831801

  18. Cleaning of endodontic files, Part I: The effect of bioburden on the sterilization of endodontic files.

    PubMed

    Johnson, M A; Primack, P D; Loushine, R J; Craft, D W

    1997-01-01

    Ninety-two new endodontic files were randomly assigned to five groups with varying parameters of contamination, cleaning method, and sterilization (steam or chemical). Files were instrumented in bovine teeth to accumulate debris and a known contaminant, Bacillus stearothermophilus. Positive controls produced growth on both T-soy agar plates and in T-soy broth. Negative controls and experimental files (some with heavy debris) failed to produce growth. The results showed that there was no significant difference between contaminated files that were not cleaned before sterilization and contaminated files that were cleaned before sterilization. Bioburden present on endodontic files does not appear to affect the sterilization process.

  19. System and method of applying energetic ions for sterilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and acrossmore » the cold plasma, is provided.« less

  20. How and why women choose sterilization: results from six follow-up surveys.

    PubMed

    Landry, E

    1990-01-01

    Follow-up surveys were carried out in six countries (Bangladesh, Columbia, El Salvador, Guatemala, Indonesia, and Tunisia) between 1984 and 1986 to assess client decision-making regarding sterilization. The results revealed that women made well-informed, voluntary decisions to be sterilized. They were knowledgeable about other family planning methods and made the decision to be sterilized after consulting their partners, friends, relatives, or other sterilized women. Although their decisions were voluntary, other findings revealed areas for improvement such as client information and education about the risks of the procedure. These data were used to improve program services by emphasizing the need for better information, education, and counseling programs.

  1. Suitability of peracetic acid for sterilization of media for mycoplasma cultures.

    PubMed Central

    Wutzler, P; Sprössig, M; Peterseim, H

    1975-01-01

    The utility of peracetic acid for sterilization of serum and yeast extract additions to mycoplasma medium was studied by culturing six Mycoplasma species. Culture media containing additions that had been sterilized with peracetic acid proved to be as good as filtered components. The use of 0.05 to 0.1% peracetic acid is recommended to sterilize the serum and yeast extract additions since savings in time and equipment can be accomplished. PMID:1100656

  2. Hysteroscopic Sterilization: History and Current Methods

    PubMed Central

    Greenberg, James A

    2008-01-01

    For many practicing obstetrician-gynecologists, tubal ligation was the gold standard by which female sterilization techniques were measured. Yet gynecologic surgeons have simultaneously sought to occlude the fallopian tubes transcervically to avoid discomfort and complications associated with transabdominal approaches. In this review, the history of transcervical sterilization is discussed. Past, current, and upcoming techniques are reviewed. This article focuses on interval sterilization techniques, thus removing post-vaginal and post-cesarean delivery tubal ligations from the discussion. PMID:19015762

  3. Effects of sterilization processes on NiTi alloy: surface characterization.

    PubMed

    Thierry, B; Tabrizian, M; Savadogo, O; Yahia, L

    2000-01-01

    Sterilization is required for using any device in contact with the human body. Numerous authors have studied device properties after sterilization and reported on bulk and surface modifications of many materials after processing. These surface modifications may in turn influence device biocompatibility. Still, data are missing on the effect of sterilization procedures on new biomaterials such as nickel-titanium (NiTi). Herein we report on the effect of dry heat, steam autoclaving, ethylene oxide, peracetic acid, and plasma-based sterilization techniques on the surface properties of NiTi. After processing electropolished NiTi disks with these techniques, surface analyses were performed by Auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements. AES analyses revealed a higher Ni concentration (6-7 vs. 1%) and a slightly thicker oxide layer on the surface for heat and ethylene oxide processed materials. Studies of surface topography by AFM showed up to a threefold increase of the surface roughness when disks were dry heat sterilized. An increase of the surface energy of up to 100% was calculated for plasma treated surfaces. Our results point out that some surface modifications are induced by sterilization procedures. Further work is required to assess the effect of these modifications on biocompatibility, and to determine the most appropriate methods to sterilize NiTi. Copyright 2000 John Wiley & Sons, Inc.

  4. Managing feral cats on a university's campuses: how many are there and is sterilization having an effect?

    PubMed

    Jones, Amanda L; Downs, Colleen T

    2011-01-01

    Worldwide domestic and feral cat (Felis catus) numbers have increased. Concerns regarding high populations of feral cats in urban areas include wildlife predation, public nuisance, and disease. This study aimed to estimate the size of the feral cat population on 5 campuses of the University of KwaZulu-Natal, South Africa, to determine whether sterilization has an effect and to make management recommendations. The study used both the total count and mark-recapture methods to estimate the feral cat population on each campus. The study chose a noninvasive method of taking photographs to "mark" individuals and record those who were sterilized. The study estimated a total of 186 cats on all campuses and density at 161 cats km(-2). There was a negative relationship between sterilization and numbers. Sites with higher sterilization showed a lower proportion of younger cats. At the average sterilization of 55%, the population, according to predictions, would remain stable at fecundity, survival, and immigration rates reported by cat caretakers. However, caretakers underestimated cat abundance by 7 ± 37 SD%. Caretakers' feral cat sterilization and feeding programs appear to provide a service to the university community. Key management recommendations were to increase sterilization to 90% to reduce the population over the long term and to raise funds to support the costs incurred by voluntary cat caretakers.

  5. "She made up a choice for me": 22 HIV-positive women's experiences of involuntary sterilization in two South African provinces.

    PubMed

    Strode, Ann; Mthembu, Sethembiso; Essack, Zaynab

    2012-12-01

    Since 1998 South African law has provided that adults should have access to sterilization but only with their informed consent. However, the right to sterilization and other sexual and reproductive rights have not been fully realized as women struggle to access limited services, and there are allegations of discrimination and sterilization abuses. This qualitative study explores the experiences of 22 HIV-positive women in two provinces who reported being sterilized between 1996 and 2010 without their informed consent (n=18) or without their knowledge (n=4). Key issues reported by participants included failure to respect their autonomy, lack of information given about what sterilization entailed, and subtle or overt pressure to sign the consent form. Although the legal framework was intended to ensure informed decision-making regarding sterilization, these protections appear to have failed the HIV-positive women in this study. The findings suggest that some health professionals may consider a signature on a consent form as sufficient regardless of how it was obtained. Furthermore the women's perceptions that they were singled out as needing to be sterilized simply because they were HIV-positive warrants further investigation. More research is required on the nature of the problem and on other stakeholders' perceptions. Copyright © 2012 Reproductive Health Matters. Published by Elsevier Ltd. All rights reserved.

  6. The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature

    PubMed Central

    Khabiri, Masoud; Ebrahimi, Maziar; Saei, Mohammad Reza

    2017-01-01

    Statement of the Problem: File fracture can interfere with cleaning and shaping of the canal and compromise periradicular healing. Autoclave sterilization may prone the files to fracture. Purpose: The purpose of the present study was to determine the effect of autoclave sterilization on the cyclic fatigue resistance of Hero642 rotary instrument in two curvatures of 45 and 60 degrees. Materials and Method: For this experimental in-vitro study, 90 Nickel-Titanium HERO 642 rotary files #30 with 0.06 taper were selected. They were divided into two groups (curvature of 45 and 60 degree) of 45 files. Each group was then subdivided into 3 subgroups; group I: no sterilization, group II: 5 cycles of sterilization and group III: 10 cycles of sterilization. Files were used in artificial canals until fracture. The cyclic fatigue was measured as the number of cycles before fracture. The data was statically analyzed by Student’s t-test and two-way analysis of variance. Results: There was a significant difference in cyclic fatigue of two curvature of 45 and 60 degrees (p= 0.001). However, sterilization process has no significant effect on cyclic fatigue of HERO files (p= 0.557). Conclusion: Sterilization had no effect on the cyclic fatigue of HERO 642 files when used in curvature of 45 or 60 degrees. PMID:29201971

  7. Chemical transformation of some biologically relevant calcium phosphates in aqueous media during a steam sterilization.

    PubMed

    Dorozhkin, S V; Schmitt, M; Bouler, J M; Daculsi, G

    2000-12-01

    The purpose of this study was to investigate the effect of steam sterilization on some biologically relevant calcium phosphates: CaHPO4 . 2H2O (DCPD), calcium deficient apatite (CDA) and biphasic calcium phosphate (BCP). Suspensions of 0.2 g of each calcium phosphate compound with 5.0 ml of deionized water were prepared and steam sterilized in an autoclave (20 min at 121 degrees C). After sterilization the suspensions were filtered and the dried solids characterized with scanning electron microscopy, IR-spectroscopy and X-ray diffraction. The pH and calcium concentrations of the filtrates were determined with ion selective electrodes. Similar measurements were made with the same samples which were not sterilized. The sterilization procedure was found to result in the dehydration of DCPD and hydration of calcium oxide incorporated into the BCP. Solution pH was observed to change from 7.3 to 5.5 for the solutions in equilibrium with DCPD and from 8.5 to 10.6 for those in equilibrium with BCP. Minor changes both with the solid and liquid phases were found to occur during the steam sterilization of CDA. These results indicate that steam sterilization may have different effects on different calcium phosphate suspensions: it can result in dehydration of DCPD, fast hydration for CaO in BCP, but no significant effect on CDA. Copyright 2000 Kluwer Academic Publishers

  8. Effect of repeated sterilization cycles on the physical properties of scaling instruments: a scanning electron microscopy study.

    PubMed

    Porto, Alessandra Nogueira; Borges, Álvaro Henrique; Semenoff-Segundo, Alex; Raslan, Suzane A; Pedro, Fábio Luis Miranda; Jorge, Antônio Olavo Cardoso; Bandeca, Matheus Coelho

    2015-05-01

    Repeated sterilizations cycles cause undesirable alterations in the material properties of the instruments, such as corrosion, alterations in the hardness of the metal and the loss of the cutting sharpness of the instrument. This research examined the effect of repeated dry heat sterilization and autoclaves cycles on carbon steel (CS) and stainless steel (SS) curettes during the scaling and root planning. A total of 77 Gracey curettes were used in this study. Of these, 35 were SS and 42 were CS curettes submitted in different process: Dry heat, autoclave, inhibition of corrosion and autoclave, scaling, root planning and dry heat, scaling, root planning, inhibition of corrosion and autoclave. The inhibition of corrosion used on the carbon curettes (prior to sterilization in the autoclave) was sodium nitrite at 2%. The curettes received 10 consecutive cycles of sterilization and after that the cutting edges were examined in the electronic microscope, at 60 and 100 magnification times. The images were evaluated by three independent examiners, who compared the photographs of each group with the control group. The surface corrosion products and a deterioration of the edges were observed and the results showed that the SS curettes suffered little alteration with sterilization, scaling, root planning whereas the CS curettes were visibly affected by sterilization in the autoclave, but when the inhibition of corrosion was used prior to the sterilization, the oxidation was considerably reduced.

  9. Lumen claims of the STERRAD 100NX sterilizer: testing performance limits when processing equipment containing long, narrow lumens.

    PubMed

    Diab-Elschahawi, Magda; Blacky, Alexander; Bachhofner, Nicole; Koller, Walter

    2011-11-01

    According to manufacturers information, the STERRAD 100NX sterilizer-a low temperature H(2)O(2) gas plasma sterilizer-can adequately process single channel stainless steel lumens with an inside diameter of 0.7 mm or larger and a maximum length of 500 mm using standard cycle sterilizing conditions. The aim of this study was to qualify the performance of this H(2)O(2) gas plasma sterilizer under different experimental settings representing worst case conditions. Inoculated carriers were placed at the midpoint position of specified lumens and then submitted to flex scope sterilizing conditions. To simulate insufficient cleaning or crystalline residues, we added organic and inorganic challenges to our inoculated carriers. For experiments done with unchallenged carriers, quantitative analysis reached a log(10) reduction rate of ≥5.71, whereas qualitative results showed no growth in 24 out of 30 biologic indicators tested using flex scope half cycle conditions. Any additional kind of challenge significantly impaired the sterilization outcome. The findings of our current study emphasize the importance of a thorough validated cleaning of medical devices as well as timing for cleaning and decontamination before being exposed to the H(2)O(2) sterilization process and, furthermore, the need for strict adherence to manufacturer's recommendations. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  10. Sterilization of Chrysomya putoria (Insecta: Diptera: Calliphoridae) Eggs for Use in Biotherapy

    PubMed Central

    Dallavecchia, Daniele Lourinho; da Silva Filho, Renato Geraldo; Aguiar, Valéria Magalhães

    2014-01-01

    Abstract Large-scale, quality-controlled laboratory production of fly larvae is needed for biotherapy. The objective of this study was to assess the action of glutaraldehyde on the sterilization of Chrysomya putoria eggs by applying pharmaceutical sterility tests. Egg masses with 0.600 g were divided into three parts of 0.200 g, the eggs were separated using sterile distilled water, and the suspensions obtained were mixed with activated 2% glutaraldehyde solution. After 15-min contact, the suspensions were filtered through Whatman filter paper, and the glutaraldehyde residue obtained in the filtrate was neutralized by rinsing with Tryptone Soy Broth. The treated eggs were placed aseptically on Petri dishes containing gauze moistened with sterile saline solution. About 10% of the sterilized mass was transferred to test tubes containing Tryptone Soy Broth and Fluid Thioglycollate Broth. The tubes were incubated, respectively, at 22.5 and 35.0°C for 14 d to verify egg mass sterility. The plates containing the rest of the eggs (90%) were sealed with plastic film and kept in a climatized chamber at 30°C/d, 28°C per night, 60 ± 10% relative humidity, and under a 12-h light period to assess insect viability and survival. Each experiment was carried out in triplicate using a biological class II safety cabinet. No change in color or turgidity was observed with the agent tested, proving the sterility of the product and that there was no trace of contamination. Forty larvae (in three replications) in the periods of 12, 24, and 48 h after sterilization, when transferred to diet, produced larvae, pupae, and total viability similar to the control (larvae without sterilization). However, for the 72- h treatment, larvae and total viability were significantly lower than for the other treatments. There was no significant difference for the pupal stage. The product tested was shown to be efficacious for use as a sterilizer of C. putoria eggs for all the parameters assessed. PMID:25399429

  11. Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.

    PubMed

    Karoshi, Mahantesh; Yoong, Wai

    2004-01-01

    In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.

  12. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.23 Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period...

  13. Hysteroscopic Tubal Sterilization

    PubMed Central

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly compare the two procedures limit this assessment. In addition, optimal placement of the microinsert at the time of hysteroscopy varied among studies. Conclusions Hysteroscopic sterilization is associated with: lower pregnancy rates compared to tubal ligation (GRADE very low) lower complication rates compared to tubal ligation (GRADE very low) no significant improvement in patient satisfaction compared to tubal ligation (GRADE very low) Plain Language Summary Hysteroscopic tubal sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the fallopian tubes, preventing the egg from moving down the tube and the sperm from reaching the egg. Tubal ligation is a surgical procedure to tie or seal the fallopian tubes, and it usually requires general anesthesia. In contrast, hysteroscopic tubal sterilization can be performed in 10 minutes in an office setting without general or even local anesthesia. A tiny device called a microinsert is inserted into each fallopian tube through the vagina, cervix, and uterus without surgery. An instrument called a hysteroscope allows the doctor to see inside the body for the procedure. Once the microinserts are in place, scar tissue forms around them and blocks the fallopian tubes. Health Quality Ontario conducted a review of the effectiveness and safety of hysteroscopic tubal sterilization compared to tubal ligation. This review indicates that hysteroscopic tubal sterilization is associated with: lower pregnancy rates compared to tubal ligation lower complication rates compared to tubal ligation no significant improvement in patient satisfaction compared to tubal ligation However, we found a number of limitations to the studies available on hysteroscopic tubal sterilization. Among other concerns, most studies did not include long-term follow-up and only 1 study directly compared hysteroscopic tubal sterilization to tubal ligation. PMID:24228084

  14. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    PubMed

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p < .05). These findings do not indicate that low-income and racial/ethnic minority women in the South use sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  15. Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak.

    PubMed

    Naryzhny, Igor; Silas, Dean; Chi, Kenneth

    2016-08-01

    Carbapenem-resistant Enterobacteriaceae (CRE) outbreaks have been implicated at several medical institutions involving gastroenterology laboratories and, specifically, duodenoscopes. Currently, there are no specific guidelines to eradicate or prevent the outbreak of this bacteria. We describe ethylene oxide (ETO) gas sterilizations of duodenoscopes to address this issue. A complete investigation of the gastroenterology laboratory and an evaluation by the Centers for Disease Control and Prevention concluded that no lapses were found in the reprocessing of the equipment. With no deficiencies to address, we began a novel cleaning process using surgical ETO gas sterilizers in addition to standard endoscope reprocessing recommendations and guidelines, all while trying to eradicate the CRE contamination and prevent future recurrences. We also instituted a surveillance system for recurrence of CRE contamination via monthly cultures of the duodenoscopes. Between October 2013 and April 2014, 589 ERCPs were performed with 645 ETO gas sterilizations of 6 duodenoscopes. Given the extra 16 hours needed to sterilize the duodenoscopes, our institution incurred costs resulting from purchasing additional equipment and surveillance cultures. Four duodenoscopes sustained damage during this period; however, this could not be directly attributed to the sterilization process. Furthermore, after an 18-month success period we encountered a positive CRE culture after sterilization, albeit of a different strain than originally detected during the outbreak. The duodenoscope underwent additional ETO gas sterilization, with a negative repeated culture; all potentially exposed individuals screened negative for CRE. Proper use of high-level disinfection alone may not eliminate multidrug-resistant organisms from duodenoscopes. In this single-center study, the addition of ETO sterilization and frequent monitoring with cultures reduced duodenoscope contamination and eliminated clinical infections. As such, ETO gas sterilization may provide benefit in further decontamination of duodenoscopes, but further investigation is necessary. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  16. Effects of different sterilization methods on the physico-chemical and bioresponsive properties of plasma-treated polycaprolactone films.

    PubMed

    Ghobeira, Rouba; Philips, Charlot; Declercq, Heidi; Cools, Pieter; De Geyter, Nathalie; Cornelissen, Ria; Morent, Rino

    2017-01-24

    For most tissue engineering applications, surface modification and sterilization of polymers are critical aspects determining the implant success. The first part of this study is thus dedicated to modifying polycaprolactone (PCL) surfaces via plasma treatment using a medium pressure dielectric barrier discharge, while the second part focuses on the sterilization of plasma-modified PCL. Chemical and physical surface changes are examined making use of water contact angle goniometry (WCA), x-ray photoelectron spectroscopy and atomic force microscopy. Bioresponsive properties are evaluated by performing cell culture tests. The results show that air and argon plasmas decrease the WCA significantly due to the incorporation of oxygen-containing functionalities onto the PCL surface, without modifying its morphology. Extended treatment times lead to PCL degradation, especially in the case of air plasma. In addition to surface modification, the plasma potential to sterilize PCL is studied with appropriate treatment times, but sterility has not been achieved so far. Therefore, plasma-modified films are subjected to UV, H 2 O 2 plasma (HP) and ethylene oxide (EtO) sterilizations. UV exposure of 3 h does not alter the PCL physico-chemical properties. A decreased wettability is observed after EtO sterilization, attributable to the modification of PCL chain ends reacting with EtO molecules. HP sterilization increases the WCA of the plasma-treated samples, presumably due to the scission of the hydrophilic bonds generated during the prior plasma treatments. Moreover, HP modifies the PCL surface morphology. For all the sterilizations, an improved cell adhesion and proliferation is observed on plasma-treated films compared to untreated ones. EtO shows the lowest proliferation rate compared to HP and UV. Overall, of the three sterilizations, UV is the most effective, since the physical alterations provoked by HP might interfere with the structural integrity when it comes to 3D scaffolds, and the chemical modifications caused by EtO, in addition to its toxicity, interfere with PCL bioactivity.

  17. Observance of Sterilization Protocol Guideline Procedures of Critical Instruments for Preventing Iatrogenic Transmission of Creutzfeldt-Jakob Disease in Dental Practice in France, 2017

    PubMed Central

    Bourgeois, Denis; Dussart, Claude; Saliasi, Ina; Laforest, Laurent; Tramini, Paul; Carrouel, Florence

    2018-01-01

    Effective sterilization of reusable instruments contaminated by Creutzfeldt–Jakob disease in dental care is a crucial issue for public health. The present cross-sectional study investigated how the recommended procedures for sterilization were implemented by French dental practices in real-world settings. A sample of dental practices was selected in the French Rhône-Alpes region. Data were collected by a self-questionnaire in 2016. Sterilization procedures (n = 33) were classified into 4 groups: (1) Pre-sterilization cleaning of reusable instruments; (2) Biological verification of sterilization cycles—Monitoring steam sterilization procedures; (3) Autoclave performance and practitioner knowledge of autoclave use; (4) Monitoring and documentation of sterilization procedures—Tracking and tracing the instrumentation. Answers were provided per procedure, along with the global implementation of procedures within a group (over 80% correctly performed). Then it was verified how adherence to procedure groups varied with the size of the dental practice and the proportion of dental assistants within the team. Among the 179 questionnaires available for the analyses, adherence to the recommended procedures of sterilization noticeably varied between practices, from 20.7% to 82.6%. The median percentages of procedures correctly implemented per practice were 58.1%, 50.9%, 69.2% and 58.2%, in Groups 1, 2, 3 and 4, respectively (corresponding percentages for performing over 80% of the procedures in the group: 23.4%, 6.6%, 46.6% and 38.6%). Dental practices ≥ 3 dental units performed significantly better (>80%) procedures of Groups 2 and 4 (p = 0.01 and p = 0.002, respectively), while no other significant associations emerged. As a rule, practices complied poorly with the recommended procedures, despite partially improved results in bigger practices. Specific training regarding sterilization procedures and a better understanding of the reasons leading to their non-compliance are needed. PMID:29693615

  18. Irradiated Male Tsetse from a 40-Year-Old Colony Are Still Competitive in a Riparian Forest in Burkina Faso

    PubMed Central

    Sow, Adama; Sidibé, Issa; Bengaly, Zakaria; Bancé, Augustin Z.; Sawadogo, Germain J.; Solano, Philippe; Vreysen, Marc J. B.; Lancelot, Renaud; Bouyer, Jeremy

    2012-01-01

    Background Tsetse flies are the cyclical vectors of African trypanosomosis that constitute a major constraint to development in Africa. Their control is an important component of the integrated management of these diseases, and among the techniques available, the sterile insect technique (SIT) is the sole that is efficient at low densities. The government of Burkina Faso has embarked on a tsetse eradication programme in the framework of the PATTEC, where SIT is an important component. The project plans to use flies from a Glossina palpalis gambiensis colony that has been maintained for about 40 years at the Centre International de Recherche-Développement sur l'Elevage en zone Subhumide (CIRDES). It was thus necessary to test the competitiveness of the sterile males originating from this colony. Methodology/Principal Findings During the period January–February 2010, 16,000 sterile male G. p. gambiensis were released along a tributary of the Mouhoun river. The study revealed that with a mean sterile to wild male ratio of 1.16 (s.d. 0.38), the abortion rate of the wild female flies was significantly higher than before (p = 0.026) and after (p = 0.019) the release period. The estimated competitiveness of the sterile males (Fried index) was 0.07 (s.d. 0.02), indicating that a sterile to wild male ratio of 14.4 would be necessary to obtain nearly complete induced sterility in the female population. The aggregation patterns of sterile and wild male flies were similar. The survival rate of the released sterile male flies was similar to that observed in 1983–1985 for the same colony. Conclusions/Significance We conclude that gamma sterilised male G. p. gambiensis derived from the CIRDES colony have a competitiveness that is comparable to their competitiveness obtained 35 years ago and can still be used for an area-wide integrated pest management campaign with a sterile insect component in Burkina Faso. PMID:22590652

  19. Modeling the effect of surgical sterilization on owned dog population size in Villa de Tezontepec, Hidalgo, Mexico, using an individual-based computer simulation model

    PubMed Central

    Kisiel, Luz Maria; Jones-Bitton, Andria; Sargeant, Jan M.; Coe, Jason B.; Flockhart, D. T. Tyler; Canales Vargas, Erick J.

    2018-01-01

    Surgical sterilization programs for dogs have been proposed as interventions to control dog population size. Models can be used to help identify the long-term impact of reproduction control interventions for dogs. The objective of this study was to determine the projected impact of surgical sterilization interventions on the owned dog population size in Villa de Tezontepec, Hidalgo, Mexico. A stochastic, individual-based simulation model was constructed and parameterized using a combination of empirical data collected on the demographics of owned dogs in Villa de Tezontepec and data available from the peer-reviewed literature. Model outcomes were assessed using a 20-year time horizon. The model was used to examine: the effect of surgical sterilization strategies focused on: 1) dogs of any age and sex, 2) female dogs of any age, 3) young dogs (i.e., not yet reached sexual maturity) of any sex, and 4) young, female dogs. Model outcomes suggested that as surgical capacity increases from 21 to 84 surgeries/month, (8.6% to 34.5% annual sterilization) for dogs of any age, the mean dog population size after 20 years was reduced between 14% and 79% compared to the base case scenario (i.e. in the absence of intervention). Surgical sterilization interventions focused only on young dogs of any sex yielded greater reductions (81% - 90%) in the mean population size, depending on the level of surgical capacity. More focused sterilization targeted at female dogs of any age, resulted in reductions that were similar to focusing on mixed sex sterilization of only young dogs (82% - 92%). The greatest mean reduction in population size (90% - 91%) was associated with sterilization of only young, female dogs. Our model suggests that targeting sterilization to young females could enhance the efficacy of existing surgical dog population control interventions in this location, without investing extra resources. PMID:29856830

  20. Chemosterilization of the sea lamprey (Petromyzon marinus)

    USGS Publications Warehouse

    Hanson, Lee H.; Manion, Patrick J.

    1978-01-01

    The chemical, P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir), was found in laboratory studies to be an effective sterilant for both sexes of adult sea lampreys (Petromyzon marinus) when given intraperitoneally at a dosage of 100 mg per kilogram of body weight. A total of 300 normal spawning-run sea lampreys and 300 injected with bisazir were released into the Big Garlic River, Marquette County, Michigan, (a small stream divided into five sections by natural barriers), to determine the effect of bisazir on the nesting and spawning behavior of the adults and on the production of larvae. The lampreys constructed and spawned in 95 nests. Sterile adults showed no abnormal nest building or spawning behavior. Sterile males competed effectively with normal males for females. Egg samples taken from nests indicated that eggs in nests where sterile males spawned with sterile or normal females did not hatch, although some embryonic development occurred. Extensive surveys with electric shockers produced no larvae in stream sections where sterile males spawned, but yielded numerous larvae in sections where normal males spawned with normal females. These findings suggest that the release of sterile males may be an effective tool in an integrated approach to control of sea lampreys in the Great Lakes.

  1. No evidence for faster male hybrid sterility in population crosses of an intertidal copepod (Tigriopus californicus).

    PubMed

    Willett, Christopher S

    2008-06-01

    Two different forces are thought to contribute to the rapid accumulation of hybrid male sterility that has been observed in many inter-specific crosses, namely the faster male and the dominance theories. For male heterogametic taxa, both faster male and dominance would work in the same direction to cause the rapid evolution of male sterility; however, for taxa lacking differentiated sex chromosomes only the faster male theory would explain the rapid evolution of male hybrid sterility. It is currently unknown what causes the faster evolution of male sterility, but increased sexual selection on males and the sensitivity of genes involved in male reproduction are two hypotheses that could explain the observation. Here, patterns of hybrid sterility in crosses of genetically divergent copepod populations are examined to test potential mechanisms of faster male evolution. The study species, Tigriopus californicus, lacks differentiated, hemizygous sex chromosomes and appears to have low levels of divergence caused by sexual selection acting upon males. Hybrid sterility does not accumulate more rapidly in males than females in these crosses suggesting that in this taxon male reproductive genes are not inherently more prone to disruption in hybrids.

  2. A White Paper on keV sterile neutrino Dark Matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adhikari, R.; Agostini, M.; Ky, N. Anh

    We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved—cosmology, astrophysics, nuclear, and particle physics—in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arisingmore » from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X-ray observations. Another focus of the paper concerns the construction of particle physics models, aiming to explain how sterile neutrinos of keV-scale masses could arise in concrete settings beyond the Standard Model of elementary particle physics. The paper ends with an extensive review of current and future astrophysical and laboratory searches, highlighting new ideas and their experimental challenges, as well as future perspectives for the discovery of sterile neutrinos.« less

  3. Chemosterilization of male sea lampreys (Petromyzon marinus) does not affect sex pheromone release

    USGS Publications Warehouse

    Siefkes, Michael J.; Bergstedt, Roger A.; Twohey, Michael B.; Li, Weiming

    2003-01-01

    Release of males sterilized by injection with bisazir is an important experimental technique in management of sea lamprey (Petromyzon marinus), an invasive, nuisance species in the Laurentian Great Lakes. Sea lampreys are semelparous and sterilization can theoretically eliminate a male's reproductive capacity and, if the ability to obtain mates is not affected, waste the sex products of females spawning with him. It has been demonstrated that spermiating males release a sex pheromone that attracts ovulating females. We demonstrated that sterilized, spermiating males also released the pheromone and attracted ovulating females. In a two-choice maze, ovulating females increased searching behavior and spent more time in the side of the maze containing chemical stimuli from sterilized, spermiating males. This attraction response was also observed in spawning stream experiments. Also, electro-olfactograms showed that female olfactory organs were equally sensitive to chemical stimuli from sterilized and nonsterilized, spermiating males. Finally, fast atom bombardment mass spectrometry showed that extracts from water conditioned with sterilized and nonsterilized, spermiating males contained the same pheromonal molecule at similar levels. We concluded that injection of bisazir did not affect the efficacy of sex pheromone in sterilized males.

  4. A White Paper on keV sterile neutrino Dark Matter

    NASA Astrophysics Data System (ADS)

    Adhikari, R.; Agostini, M.; Ky, N. Anh; Araki, T.; Archidiacono, M.; Bahr, M.; Baur, J.; Behrens, J.; Bezrukov, F.; Bhupal Dev, P. S.; Borah, D.; Boyarsky, A.; de Gouvea, A.; Pires, C. A. de S.; de Vega, H. J.; Dias, A. G.; Di Bari, P.; Djurcic, Z.; Dolde, K.; Dorrer, H.; Durero, M.; Dragoun, O.; Drewes, M.; Drexlin, G.; Düllmann, Ch. E.; Eberhardt, K.; Eliseev, S.; Enss, C.; Evans, N. W.; Faessler, A.; Filianin, P.; Fischer, V.; Fleischmann, A.; Formaggio, J. A.; Franse, J.; Fraenkle, F. M.; Frenk, C. S.; Fuller, G.; Gastaldo, L.; Garzilli, A.; Giunti, C.; Glück, F.; Goodman, M. C.; Gonzalez-Garcia, M. C.; Gorbunov, D.; Hamann, J.; Hannen, V.; Hannestad, S.; Hansen, S. H.; Hassel, C.; Heeck, J.; Hofmann, F.; Houdy, T.; Huber, A.; Iakubovskyi, D.; Ianni, A.; Ibarra, A.; Jacobsson, R.; Jeltema, T.; Jochum, J.; Kempf, S.; Kieck, T.; Korzeczek, M.; Kornoukhov, V.; Lachenmaier, T.; Laine, M.; Langacker, P.; Lasserre, T.; Lesgourgues, J.; Lhuillier, D.; Li, Y. F.; Liao, W.; Long, A. W.; Maltoni, M.; Mangano, G.; Mavromatos, N. E.; Menci, N.; Merle, A.; Mertens, S.; Mirizzi, A.; Monreal, B.; Nozik, A.; Neronov, A.; Niro, V.; Novikov, Y.; Oberauer, L.; Otten, E.; Palanque-Delabrouille, N.; Pallavicini, M.; Pantuev, V. S.; Papastergis, E.; Parke, S.; Pascoli, S.; Pastor, S.; Patwardhan, A.; Pilaftsis, A.; Radford, D. C.; Ranitzsch, P. C.-O.; Rest, O.; Robinson, D. J.; Rodrigues da Silva, P. S.; Ruchayskiy, O.; Sanchez, N. G.; Sasaki, M.; Saviano, N.; Schneider, A.; Schneider, F.; Schwetz, T.; Schönert, S.; Scholl, S.; Shankar, F.; Shrock, R.; Steinbrink, N.; Strigari, L.; Suekane, F.; Suerfu, B.; Takahashi, R.; Van, N. Thi Hong; Tkachev, I.; Totzauer, M.; Tsai, Y.; Tully, C. G.; Valerius, K.; Valle, J. W. F.; Venos, D.; Viel, M.; Vivier, M.; Wang, M. Y.; Weinheimer, C.; Wendt, K.; Winslow, L.; Wolf, J.; Wurm, M.; Xing, Z.; Zhou, S.; Zuber, K.

    2017-01-01

    We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved—cosmology, astrophysics, nuclear, and particle physics—in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arising from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X-ray observations. Another focus of the paper concerns the construction of particle physics models, aiming to explain how sterile neutrinos of keV-scale masses could arise in concrete settings beyond the Standard Model of elementary particle physics. The paper ends with an extensive review of current and future astrophysical and laboratory searches, highlighting new ideas and their experimental challenges, as well as future perspectives for the discovery of sterile neutrinos.

  5. Effects of steam sterilization on thermogelling chitosan-based gels.

    PubMed

    Jarry, C; Chaput, C; Chenite, A; Renaud, M A; Buschmann, M; Leroux, J C

    2001-01-01

    A new thermogelling chitosan-glycerophosphate system has been recently proposed for biomedical applications such as drug and cell delivery. The objectives of this work were to characterize the effect of steam sterilization on the in vitro and in vivo end performances of the gel and to develop a filtration-based method to assess its sterility. Autoclaving 2% (w/v) chitosan solutions for as short as 10 min resulted in a 30% decrease in molecular weight, 3-5-fold decrease in dynamic viscosity, and substantial loss of mechanical properties of the resulting gel. However, sterilization did not impair the ability of the system to form a gel at 37 degrees C. The antimicrobial activity of chitosan against several microorganisms was evaluated after inoculation of chitosan solutions and removal of the cells by filtration. It was found that, although chitosan was bacteriostatic against the heat sterilization bioindicator Bacillus stearothermophilus, the bacteria could rapidly grow after separation from the chitosan solution by filtration. This indicated that B. stearothermophilus is an adequate strain to validate a heat sterilization method on chitosan preparations, and accordingly this strain was used to assess the sterility of chitosan solution following a 10 min autoclaving time. Copyright 2001 John Wiley & Sons, Inc.

  6. Gas plasma sterilization of microorganisms and mechanisms of action

    PubMed Central

    SHINTANI, HIDEHARU; SAKUDO, AKIKAZU; BURKE, PETER; McDONNELL, GERALD

    2010-01-01

    The use of true gas plasmas for the inactivation of microorganisms is an area of dynamic research. Many types of gases are used as a source of plasma, and different plasma production methods have been applied. The antimicrobial mechanisms of oxygen-based gas plasmas may be due to an etching effect on microbial structures, particularly bacterial endospores resulting in shrinkage. By contrast, the definite mechanisms of actions of other gas plasma sources, such as N2, He, Ne, Ar and Xe gases, have not been clearly defined and indeed may be distinct. The speculated mechanisms of these gas plasmas involve the direct attack of metastable (excited molecular), UV and/or VUV to microbial structures, specifically the inner membrane and DNA in the core of bacterial endospores. According to this speculation, sterilized spore figures would remain unchanged. However, these mechanisms remain to be clarified. Future perspectives on the use of gas plasma for sterilization are of interest, as it is possible that appropriate sterility assurance levels can be obtained in parallel with material and functional compatibility. Traditional sterilization methods are often limited in these requirements. Therefore, gas plasma sterilization may prove to be an appropriate alternative sterilization procedure. PMID:22993596

  7. Genetic architecture of autosome-mediated hybrid male sterility in Drosophila.

    PubMed

    Marín, I

    1996-04-01

    Several estimators have been developed for assessing the number of sterility factors in a chromosome based on the sizes of fertile and sterile introgressed fragments. Assuming that two factors are required for producing sterility, simulations show that one of these, twice the inverse of the relative size of the largest fertile fragment, provides good average approximations when as few as five fertile fragments are analyzed. The estimators have been used for deducing the number of factors from previous data on several pairs of species. A particular result contrasts with the authors' interpretations: instead of the high number of sterility factors suggested, only a few per autosome are estimated in both reciprocal crosses involving Drosophila buzzatii and D. koepferae. It has been possible to map these factors, between three and six per chromosome, in the autosomes 3 and 4 of these species. Out of 203 introgressions of different fragments or combinations of fragments, the outcome of at least 192 is explained by the mapped zones. These results suggest that autosome-mediated sterility in the male hybrids of these species is mediated by a few epistatic factors, similarly to X-mediated sterility in the hybrids of other Drosophila species.

  8. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION AT...

  9. Basics of compounding sterile preparations: nomenclature and considerations.

    PubMed

    Allen, Loyd V

    2014-01-01

    This article focuses on sterile dosage forms and serves as a review for those trained in compounding sterile preparations, as well as to educate those that have not received any formal training on the topics of nomenclature and composition. The use of proper terminology is important for proper/accurate communications among healthcare practitioners. Proper terminology also has potential legal/liability implications. In addition to terminology considerations, it is important to be aware of the different routes of administration of sterile formulations and their different compositions and uses.

  10. [Spontaneous and induced sterility by ethyl methanesulfonate (EMS) in Nigella damascena L].

    PubMed

    Gilot-Delhalle, J

    1976-01-01

    EMS-induced sterility could be very partially due to chromosomal aberrations appearing during male and female meiosis or even to mechanical abnormalities of the double fertilization. The sterility could be also related to diplontic origin (lethal factors or small deficiencies appearing in homozygous state on account of self-pollinization). Owing to our histological and genetical data, a female gametophytic origin could be mainly ascribed to EMS induced sterility. It could arise from a damage of the feeding function of the nucellus.

  11. Effects of sterilization methods on key properties of specialty optical fibers used in medical devices

    NASA Astrophysics Data System (ADS)

    Stolov, Andrei A.; Slyman, Brian E.; Burgess, David T.; Hokansson, Adam S.; Li, Jie; Allen, R. Steve

    2013-03-01

    Optical fibers with different types of polymer coatings were exposed to three sterilization conditions: multiple autoclaving, treatment with ethylene oxide and treatment with gamma rays. Effects of different sterilization techniques on key optical and mechanical properties of the fibers are reported. The primary attention is given to behavior of the coatings in harsh sterilization environments. The following four coating/buffer types were investigated: (i) dual acrylate, (ii) polyimide, (iii) silicone/PEEK and (iv) fluoroacrylate hard cladding/ETFE.

  12. Microwave sterilization of Candida on underwear fabric. A preliminary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedrich, E.G. Jr.; Phillips, L.E.

    1988-05-01

    Candida-contaminated underwear might not be sterilized by ordinary laundering. The effectiveness of microwaving against Candida albicans on fabric was therefore determined. Swatches of Candida-impregnated cotton underpants fabric were subjected to domestic microwaving at the high setting for up to 30 minutes. If the fabric was microwaved dry, the Candida organisms survived. If the fabric was moistened, sterilization occurred within five minutes. Microwaving wet, freshly laundered cotton underpants should sterilize residual Candida and reduce the risk of reinfection.

  13. Comparison of low-temperature hydrogen peroxide gas plasma sterilization for endoscopes using various Sterrad models.

    PubMed

    Okpara-Hofmann, J; Knoll, M; Dürr, M; Schmitt, B; Borneff-Lipp, M

    2005-04-01

    This study compared the effectiveness of sterilizing four types of endoscope using different models of the Sterrad system (Sterrad 50, 100, 100S and 200). Sterilization levels meeting international requirements were attained in all cases with carriers inoculated with Geobacillus stearothermophilus spores. The endoscopes were tested in half cycles ('overkill'). This is the first study to compare the Sterrad models marketed to date in terms of effective sterilization of endoscopes with narrow lumens.

  14. Evaluation of sterilization of dental handpieces by heating in synthetic compressor lubricant.

    PubMed

    Silverstone, S E; Hill, D E

    1999-01-01

    The Centers for Disease Control and Prevention and the American Dental Association guidelines recommend sterilization of dental handpieces after each use. Steam autoclaving is the most commonly used sterilization method. However, pressurized steam causes corrosion and partial combustion of the handpiece lubricant, leaving a sticky carbon residue on the turbine which must then be replaced after several usages. Replacement of autoclave-damaged dental handpieces represents a major expense for dentists that may be avoided through the use of less destructive sterilization techniques.

  15. Transcervical Sterilization: A Comparison of Essure® Permanent Birth Control System and Adiana® Permanent Contraception System

    PubMed Central

    Palmer, Sophia N; Greenberg, James A

    2009-01-01

    Transcervical sterilization has moved female sterilization from a minimally invasive laparoscopic technique, which requires entry into the abdominal cavity, to a less invasive hysteroscopic procedure. Along with the decreased potential for complications, its ease of performance with minimal anesthesia has facilitated a move from the operating room to the office. This review compares the available data on transcervical sterilization procedures to better understand the strengths and weakness of each system. PMID:19609402

  16. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  17. Search for Sterile Neutrinos Using the MiniBooNE Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorel, Michel

    2005-01-01

    The possible existence of light sterile neutrinos in Nature is motivated, and the prospects to extend sterile neutrino searches beyond current limits is substantiated, using the MiniBooNE neutrino beam and detector at Fermilab. We report on the neutrino flux predictions for the MiniBooNE experiment, on the characterization of the charged-current, quasi-elastic interactions of muon neutrinos ({nu}{sub {mu}}n {yields} {mu}{sup -}p) observed, and on the experiment's sensitivity to sterile neutrinos via muon neutrino disappearance.

  18. Reconsidering racial/ethnic differences in sterilization in the United States.

    PubMed

    White, Kari; Potter, Joseph E

    2014-06-01

    Cross-sectional studies have found that low-income and racial/ethnic minority women are more likely to use female sterilization and less likely to rely on a partner's vasectomy than women with higher incomes and whites. However, studies of pregnant and postpartum women report that racial/ethnic minorities, particularly low-income minority women, face greater barriers in obtaining a sterilization than do whites and those with higher incomes. In this paper, we address this apparent contradiction by examining the likelihood a woman gets a sterilization following each delivery, which removes from the comparison any difference in the number of births she has experienced. Using the 2006-2010 National Survey of Family Growth, we fit multivariable-adjusted logistic and Cox regression models to estimate odds ratios and hazard ratios for getting a postpartum or interval sterilization, respectively, according to race/ethnicity and insurance status. Women's chances of obtaining a sterilization varied by both race/ethnicity and insurance. Among women with Medicaid, whites were more likely to use female sterilization than African Americans and Latinas. Privately insured whites were more likely to rely on vasectomy than African Americans and Latinas, but among women with Medicaid-paid deliveries reliance on vasectomy was low for all racial/ethnic groups. Low-income racial/ethnic minority women are less likely to undergo sterilization following delivery compared to low-income whites and privately insured women of similar parities. This could result from unique barriers to obtaining permanent contraception and could expose women to the risk of future unintended pregnancies. Low-income minorities are less likely to undergo sterilization than low-income whites and privately insured minorities, which may result from barriers to obtaining permanent contraception, and exposes women to unintended pregnancies. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Female sterilization is more common among women with physical and/or sensory disabilities than women without disabilities in the United States.

    PubMed

    Wu, Justine P; McKee, Michael M; Mckee, Kimberly S; Meade, Michelle A; Plegue, Melissa; Sen, Ananda

    2017-07-01

    Female sterilization accounts for 50% of all contraceptive use in the U.S. The extent to which U.S. women with physical and/or sensory disabilities have undergone female sterilization is unknown. Our primary objective was to determine the prevalence of sterilization for women with physical/sensory disabilities, and compare this to the prevalence for women without disabilities. We also compared use of long-acting reversible contraceptive (LARC) methods between women with and without disabilities. We conducted a secondary analysis of data from the National Survey of Family Growth 2011-2013, a population-based survey of U.S. women aged 15-44. Bivariate comparisons between women with and without disabilities by female sterilization and LARC use were conducted using chi-square tests. Using logistic regression, we estimated the odds of female sterilization based upon disability status. Women with physical/sensory disabilities accounted for 9.3% of the total sample (N = 4966). Among women with disabilities only, 28.2% had undergone female sterilization, representing 1.2 million women nationally. LARC use was lower among women with disabilities than those without disabilities (5.4%, 9.3%, respectively, p < 0.01). After adjusting for age, race/ethnicity, education, insurance, marital status, parity, and self-reported health, women with disabilities had higher odds of sterilization (OR 1.36, 95% CI 1.03, 1.79). The odds of female sterilization is higher among women with physical/sensory disabilities than those without disabilities. Future research is necessary to understand factors contributing to this finding, including possible underutilization of LARC methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Marital Status and Female and Male Contraceptive Sterilization in the United States

    PubMed Central

    Eeckhaut, Mieke Carine Wim

    2015-01-01

    Objective To examine female and male sterilization patterns in the United States based on marital status, and to determine if sociodemographic characteristics explain these sterilization patterns. Design Survival analysis of cross-sectional data from the female and male samples of the 2006–2010 National Survey of Family Growth (NSFG). Setting A trained female interviewer conducted in-home interviews. Patient(s) The 2006–2010 NSFG is designed to be representative of the U.S. civilian non-institutionalized population ages 15–44. Intervention(s) None. Main outcome measure(s) Vasectomy and tubal sterilization. Result(s) In the United States, vasectomy is the near exclusive domain of married men. Never- and ever-married single men and never-married cohabiting men had a low relative risk of vasectomy (RRs=0.1, 0.3, and 0.0, respectively) when compared to men in first marriages. Tubal sterilization was not limited to currently married, or even to ever-married women, though it was less common among never-married single women (RR=0.2) and more common among women in higher-order marriages (RR=1.8), as compared to women in first marriages. In contrast to vasectomy, differential use of tubal sterilization by marital status was driven in large part by differences in parity. Conclusion(s) This study shows that being unmarried at sterilization—an important risk factor for post-sterilization regret—was much more common among women than men. In addition to contributing to the predominance of female versus male sterilization, this pattern highlights the importance of educating women on the permanency of sterilization, as well as an opportunity to increase reliance on long-acting reversible contraceptive methods. PMID:25881875

  1. Prevalence and clinical significance of sterile intra-amniotic inflammation in patients with preterm labor and intact membranes.

    PubMed

    Romero, Roberto; Miranda, Jezid; Chaiworapongsa, Tinnakorn; Korzeniewski, Steven J; Chaemsaithong, Piya; Gotsch, Francesca; Dong, Zhong; Ahmed, Ahmed I; Yoon, Bo Hyun; Hassan, Sonia S; Kim, Chong Jai; Yeo, Lami

    2014-11-01

    Inflammation and infection play a major role in preterm birth. The purpose of this study was to (i) determine the prevalence and clinical significance of sterile intra-amniotic inflammation and (ii) examine the relationship between amniotic fluid (AF) concentrations of high mobility group box-1 (HMGB1) and the interval from amniocentesis to delivery in patients with sterile intra-amniotic inflammation. AF samples obtained from 135 women with preterm labor and intact membranes were analyzed using cultivation techniques as well as broad-range PCR and mass spectrometry (PCR/ESI-MS). Sterile intra-amniotic inflammation was defined when patients with negative AF cultures and without evidence of microbial footprints had intra-amniotic inflammation (AF interleukin-6 ≥ 2.6 ng/mL). (i) The frequency of sterile intra-amniotic inflammation was significantly greater than that of microbial-associated intra-amniotic inflammation [26% (35/135) versus 11% (15/135); (P = 0.005)], (ii) patients with sterile intra-amniotic inflammation delivered at comparable gestational ages had similar rates of acute placental inflammation and adverse neonatal outcomes as patients with microbial-associated intra-amniotic inflammation, and (iii) patients with sterile intra-amniotic inflammation and high AF concentrations of HMGB1 (≥8.55 ng/mL) delivered earlier than those with low AF concentrations of HMGB1 (P = 0.02). (i) Sterile intra-amniotic inflammation is more frequent than microbial-associated intra-amniotic inflammation, and (ii) we propose that danger signals participate in sterile intra-amniotic inflammation in the setting of preterm labor. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  2. Map-based cloning and characterization of Zea mays male sterility33 (ZmMs33) gene, encoding a glycerol-3-phosphate acyltransferase.

    PubMed

    Xie, Ke; Wu, Suowei; Li, Ziwen; Zhou, Yan; Zhang, Danfeng; Dong, Zhenying; An, Xueli; Zhu, Taotao; Zhang, Simiao; Liu, Shuangshuang; Li, Jinping; Wan, Xiangyuan

    2018-06-01

    Map-based cloning of maize ms33 gene showed that ZmMs33 encodes a sn-2 glycerol-3-phosphate acyltransferase, the ortholog of rice OsGPAT3, and it is essential for male fertility in maize. Genetic male sterility has been widely studied for its biological significance and commercial value in hybrid seed production. Although many male-sterile mutants have been identified in maize (Zea mays L.), it is likely that most genes that cause male sterility are unknown. Here, we report a recessive genetic male-sterile mutant, male sterility33 (ms33), which displays small, pale yellow anthers, and complete male sterility. Using a map-based cloning approach, maize GRMZM2G070304 was identified as the ms33 gene (ZmMs33). ZmMs33 encodes a novel sn-2 glycerol-3-phosphate acyltransferase (GPAT) in maize. A functional complementation experiment showed that GRMZM2G070304 can rescue the male-sterile phenotype of the ms33-6029 mutant. GRMZM2G070304 was further confirmed to be the ms33 gene via targeted knockouts induced by the clustered regularly interspersed short palindromic repeats (CRISPR)/Cas9 system. ZmMs33 is preferentially expressed in the immature anther from the quartet to early-vacuolate microspore stages and in root tissues at the fifth leaf growth stage. Phylogenetic analysis indicated that ZmMs33 and OsGPAT3 are evolutionarily conserved for anther and pollen development in monocot species. This study reveals that the monocot-specific GPAT3 protein plays an important role in male fertility in maize, and ZmMs33 and mutants in this gene may have value in maize male-sterile line breeding and hybrid seed production.

  3. Search for the sterile neutrino mixing with the ICAL detector at INO

    NASA Astrophysics Data System (ADS)

    Behera, S. P.; Ghosh, Anushree; Choubey, Sandhya; Datar, V. M.; Mishra, D. K.; Mohanty, A. K.

    2017-05-01

    The study has been carried out on the prospects of probing the sterile neutrino mixing with the magnetized iron calorimeter (ICAL) at the India-based Neutrino Observatory (INO), using atmospheric neutrinos as a source. The so-called 3 + 1 scenario is considered for active-sterile neutrino mixing and lead to projected exclusion curves in the sterile neutrino mass and mixing angle plane. The analysis is performed using the neutrino event generator NUANCE, modified for ICAL, and folded with the detector resolutions obtained by the INO collaboration from a full GEANT4-based detector simulation. A comparison has been made between the results obtained from the analysis considering only the energy and zenith angle of the muon and combined with the hadron energy due to the neutrino induced event. A small improvement has been observed with the addition of the hadron information to the muon. In the analysis we consider neutrinos coming from all zenith angles and the Earth matter effects are also included. The inclusion of events from all zenith angles improves the sensitivity to sterile neutrino mixing by about 35% over the result obtained using only down-going events. The improvement mainly stems from the impact of Earth matter effects on active-sterile mixing. The expected precision of ICAL on the active-sterile mixing is explored and the allowed confidence level (C.L.) contours presented. At the assumed true value of 10° for the sterile mixing angles and marginalization over Δ m^2_{41} and the sterile mixing angles, the upper bound at 90% C.L. (from two-parameter plots) is around 20^deg; for θ _{14} and θ _{34}, and about 12°c for θ _{24}.

  4. A general method for identifying major hybrid male sterility genes in Drosophila.

    PubMed

    Zeng, L W; Singh, R S

    1995-10-01

    The genes responsible for hybrid male sterility in species crosses are usually identified by introgressing chromosome segments, monitored by visible markers, between closely related species by continuous backcrosses. This commonly used method, however, suffers from two problems. First, it relies on the availability of markers to monitor the introgressed regions and so the portion of the genome examined is limited to the marked regions. Secondly, the introgressed regions are usually large and it is impossible to tell if the effects of the introgressed regions are the result of single (or few) major genes or many minor genes (polygenes). Here we introduce a simple and general method for identifying putative major hybrid male sterility genes which is free of these problems. In this method, the actual hybrid male sterility genes (rather than markers), or tightly linked gene complexes with large effects, are selectively introgressed from one species into the background of another species by repeated backcrosses. This is performed by selectively backcrossing heterozygous (for hybrid male sterility gene or genes) females producing fertile and sterile sons in roughly equal proportions to males of either parental species. As no marker gene is required for this procedure, this method can be used with any species pairs that produce unisexual sterility. With the application of this method, a small X chromosome region of Drosophila mauritiana which produces complete hybrid male sterility (aspermic testes) in the background of D. simulans was identified. Recombination analysis reveals that this region contains a second major hybrid male sterility gene linked to the forked locus located at either 62.7 +/- 0.66 map units or at the centromere region of the X chromosome of D. mauritiana.

  5. Women's Awareness of, Interest in, and Experiences with Long-acting Reversible and Permanent Contraception.

    PubMed

    Burns, Bridgit; Grindlay, Kate; Dennis, Amanda

    2015-01-01

    Long-acting reversible contraception (LARC) and sterilization are popular contraceptive methods. However, they have been associated with safety concerns and coercive practices. We aimed to understand women's opinions and experiences related to these methods, including whether the methods' fraught histories influence use or interest. Between May and July 2013, we conducted an online survey with a convenience sample of 520 women aged 14 to 45. We used quota sampling to ensure women of color were at least 60% of our sample. Descriptive statistics, χ(2) tests, and multivariable logistic regression were used to estimate participants' awareness of, interest in, and experiences with LARCs and sterilization. Overall, 30% of women reported current LARC use and 67% interest in future LARC use. Four percent reported sterilization use and 48% interest in future sterilization. In multivariate analyses, current LARC use was lower among Asian women versus White women (odds ratio [OR], 0.24), and interest in future use was higher among women aged 14 to 24 versus 35 to 45 (OR, 5.49). Interest in sterilization was higher among women aged 14 to 24 and 25 to 34 versus 35 to 45 (ORs, 3.29-3.66) and women with disabilities (OR, 1.64), and lower among Black compared with White women (OR, 0.41). Method misperceptions were evident, and concerns about contraceptive coercion were reported. Concerns about contraceptive coercion were not predominant reasons for noninterest in LARCs and sterilization, but were reported by some participants. Lower sterilization interest among Black women and higher sterilization interest among women with disabilities warrant further research. Efforts to address misperceptions about LARCs and sterilization, including their safety and efficacy, are needed. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  6. Cytoplasmic effects on DNA methylation between male sterile lines and the maintainer in wheat (Triticum aestivum L.).

    PubMed

    Ba, Qingsong; Zhang, Gaisheng; Niu, Na; Ma, Shoucai; Wang, Junwei

    2014-10-01

    Male sterile cytoplasm plays an important role in hybrid wheat, and three-line system including male sterile (A line), its maintainer (B line) and restoring (R line) has played a major role in wheat hybrid production. It is well known that DNA methylation plays an important role in gene expression regulation during biological development in wheat. However, no reports are available on DNA methylation affected by different male sterile cytoplasms in hybrid wheat. We employed a methylation-sensitive amplified polymorphism technique to characterize nuclear DNA methylation in three male sterile cytoplasms. A and B lines share the same nucleus, but have different cytoplasms which is male sterile for the A and fertile for the B. The results revealed a relationship of DNA methylation at these sites specifically with male sterile cytoplasms, as well as male sterility, since the only difference between the A lines and B line was the cytoplasm. The DNA methylation was markedly affected by male sterile cytoplasms. K-type cytoplasm affected the methylation to a much greater degree than T-type and S-type cytoplasms, as indicated by the ratio of methylated sites, ratio of fully methylated sites, and polymorphism between A lines and B line for these cytoplasms. The genetic distance between the cytoplasm and nucleus for the K-type is much greater than for the T- and S-types because the former is between Aegilops genus and Triticum genus and the latter is within Triticum genus between Triticum spelta and Triticum timopheevii species. Thus, this difference in genetic distance may be responsible for the variation in methylation that we observed. Copyright © 2014. Published by Elsevier B.V.

  7. [Is female sterilization voluntary in El Salvador]?].

    PubMed

    Bertrand, J T; Landry, E G; Araya Zelaya, J D

    1986-01-01

    Sexual sterilization has become an increasingly important family planning method in developing countries, and notably so in Latin America, but some controversy has surrounded the practice because of the suggestion that individuals are coerced into undergoing sterilization. With the goal of examining allegations that low-income women in El Salvador are sterilized without their full knowledge or consent in family planning programs financed by the US, researchers interviewed 648 women who had received the operation in one of 7 facilities in El Salvador. In general, women were interviewed 1 month after their operation, by 6 trained female interviewers, with the assurance that the follow-up effort was not in any way connected with the facility performing the operation. An effort to sample approximately the same number of women from each facility was not entirely successful because of access difficulties. Most interviewees had been sterilized at below 30 years of age (average age at sterilization was 28 years), had begun having children in adolescence, and had not received more than a primary education. They had an average of 3.4 children and 1/3 had experienced the death of at least 1 child. The response to the survey indicated that female sterilization in El Salvador is voluntary. Women were shown to be aware of other contraception options. They had found out about sterilization and had become further informed about the method through providers and through communications with other women who had known about the operation at least 3 years before making a decision to submit to it, and many had waited between 1 month and 1 year before/between the decision and the actual operation. Only 1 women claimed to have felt pressured to be sterilized, identifying her mother as the source of the pressure.

  8. THE POSSIBLE USE OF IONIZING RADIATION FOR THE STERILIZATION OF CERTAIN BIOLOGICAL PREPARATIONS. I. THE INFLUENCE OF IONIZING RADIATION UPON GAS-GANGRENE AND TETANUS ANTI-SERUM (SEROLOGICAL AND ELECTROPHORETIC INVESTIGATION)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goncharenko, I.M.

    1961-12-01

    The antltoxic properties and the relative proportion of the protein fractions of gas-gangrene and tetanus antisera were studied. The results show that the sterilization of dried antisera with gamma rays caused no marked decrease in the antitoxin titre. Similar results were obtained with liquid antisera containing 0.3% mercamine. However, crude and concentrated liquid antisera after sterilization by radiation showed a marked decrease in antitoxin titre. Under the usual conditions, sterilization of liquid antisera appears to be inadvsable, not-withstanding the simpliclty, convenience, and reliabillty of the method; sterilization of dried antisera, however, offers better prospects. (P. C.H.)

  9. Characteristics of surface sterilization using electron cyclotron resonance plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2016-07-01

    The characteristics of surface sterilization using electron cyclotron resonance (ECR) plasma were investigated. High-energy electrons and oxygen radicals were observed in the ECR zone using electric probe and optical emission spectroscopic methods. A biological indicator (BI), Geobacillus stearothermophilus, containing 1 × 106 spores was sterilized in 120 s by exposure to oxygen discharges while maintaining a temperature of approximately 55 °C at the BI installation position. Oxygen radicals and high-energy electrons were found to be the sterilizing species in the ECR region. It was demonstrated that the ECR plasma could be produced in narrow tubes with an inner diameter of 5 mm. Moreover, sterilization tests confirmed that the spores present inside the narrow tube were successfully inactivated by ECR plasma irradiation.

  10. 42 CFR 50.205 - Consent form requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.205 Consent form... person who obtains the consent; and (4) The physician who will perform the sterilization procedure. (c... performing the sterilization must certify by signing the consent form, that: (i) Shortly before the...

  11. Postoperative inflammatory reactions to intraocular lense sterilized with ethylene-oxide.

    PubMed

    Stark, W J; Rosenblum, P; Maumenee, A E; Cowan, C L

    1980-05-01

    Postoperative inflammatory complications after intraocular lens implantation have increased since we have been using lenses manufactured by American companies and sterilized with ethylene-oxide, as compared with lenses from European companies sterilized by sodium hydroxide. The possible sources of this complication are discussed.

  12. Shelf-stable egg-based products processed by high pressure thermal sterilization

    USDA-ARS?s Scientific Manuscript database

    Producing a thermally sterilized egg-based product with increased shelf life without losing the sensory and nutritional properties of the freshly prepared product is challenging. Until recently, all commercial shelf-stable egg-based products were sterilized using conventional thermal processing; how...

  13. The genetics of inviability and male sterility in hybrids between Anopheles gambiae and An. arabiensis.

    PubMed

    Slotman, M; Della Torre, A; Powell, J R

    2004-05-01

    Male hybrids between Anopheles gambiae and An. arabiensis suffer from hybrid sterility, and inviability effects are sometimes present as well. We examined the genetic basis of these reproductive barriers between the two species, using 21 microsatellite markers. Generally, recessive inviability effects were found on the X chromosome of gambiae that are incompatible with at least one factor on each arabiensis autosome. Inviability is complete when the gambiae and arabiensis inviability factors are hemi- or homozygous. Using a QTL mapping approach, regions that contribute to male hybrid sterility were also identified. The X chromosome has a disproportionately large effect on male hybrid sterility. Additionally, several moderate-to-large autosomal QTL were found in both species. The effect of these autosomal QTL is contingent upon the presence of an X chromosome from the other species. Substantial regions of the autosomes do not contribute markedly to male hybrid sterility. Finally, no evidence for epistatic interactions between conspecific sterility loci was found.

  14. Safe use of chemicals for sterilization in healthcare.

    PubMed

    Warburton, P Richard

    2012-01-01

    Chemical sterilization is necessary for temperature sensitive items that cannot be sterilized with steam. These chemical sterilants are by their nature hazardous; otherwise, they would not function well. Modern sterilizers and associated equipment are designed so that these chemicals can be used safely. Whether through mechanical failure, wear and tear, or user error, leaks do sometimes occur. The maximum chemical exposure is determined by OSHA permissible exposure limits, if available, and if not available, employers should use recognized standards. Employers have a duty to ensure safe work environment and take appropriate action to mitigate potential risks. Employers should therefore assess the hazards of the chemicals used, the potential modes for leakage, means for identifying leaks and the risk of exposure of employees. Ideally, work practices should be developed by healthcare facilities so that sterile processing employees know what to do in case of a chemical leak or spill, and how to safely use these chemicals to ensure their own, and patient safety.

  15. Conflict over reproduction in an ant-plant symbiosis: why Allomerus octoarticulatus ants sterilize Cordia nodosa trees.

    PubMed

    Frederickson, Megan E

    2009-05-01

    The evolutionary stability of mutualism is thought to depend on how well the fitness interests of partners are aligned. Because most ant-myrmecophyte mutualisms are persistent and horizontally transmitted, partners share an interest in growth but not in reproduction. Resources invested in reproduction are unavailable for growth, giving rise to a conflict of interest between partners. I investigated whether this explains why Allomerus octoarticulatus ants sterilize Cordia nodosa trees. Allomerus octoarticulatus nests in the hollow stem domatia of C. nodosa. Workers protect C. nodosa leaves against herbivores but destroy inflorescences. Using C. nodosa trees with Azteca ants, which do not sterilize their hosts, I cut inflorescences off trees to simulate sterilization by A. octoarticulatus. Sterilized C. nodosa grew faster than control trees, providing evidence for a trade-off between growth and reproduction. Allomerus octoarticulatus manipulates this trade-off to its advantage; sterilized trees produce more domatia and can house larger, more fecund colonies.

  16. Comparison of two radio-frequency plasma sterilization processes using microspot evaluation of microbial inactivation.

    PubMed

    Lassen, Klaus S; Johansen, Jens E; Grün, Reinar

    2006-07-01

    In this study, we evaluated gas plasma surface sterilization methods in a specific sterilizer. We have introduced a new monitoring method using 0.4 microm pore size membranes, which in this study gave the information corresponding to 3000 exposed biological indicators per treatment cycle. This enabled us to compare the fraction of inoculates that showed no growth after exposure for 30 different locations in the chamber, and hereby identify weak and strong spots in the chamber with regard to sporicidal effect. Membranes were also used to expose a broad spectrum of soil bacteria for plasma treatment at four different conditions. The organisms were identified using PCR and sequencing. The test showed that Bacillus stearothermophilus spores were inactivated at the slowest rate among the tested microorganisms. Further alpha-proteobacteria (Gram negative) seemed more sensitive than the rest of the tested organisms. The microspot evaluation approach has been a most useful tool in the assessment of sterilization performance in sterilizers that do not have clear measurable parameters related to the sterilization.

  17. Assessing the putative roles of X-autosome and X-Y interactions in hybrid male sterility of the Drosophila bipectinata species complex.

    PubMed

    Mishra, Paras Kumar; Singh, Bashisth Narayan

    2007-07-01

    Interspecific F1 hybrid males of the Drosophila bipectinata species complex are sterile, while females are fertile, following Haldane's rule. A backcross scheme involving a single recessive visible marker on the X chromosome has been used to assess the putative roles of X-autosome and X-Y interactions in hybrid male sterility in the D. bipectinata species complex. The results suggest that X-Y interactions are playing the major role in hybrid male sterility in the crosses D. bipectinata x D. parabipectinata and D. bipectinata x D. pseudoananassae, while X-autosome interactions are largely involved in hybrid male sterility in the crosses D. malerkotliana x D. bipectinata and D. malerkotliana x D. parabipectinata. However, by using this single marker it is not possible to rule out the involvement of autosome-autosome interactions in hybrid male sterility. These findings also lend further support to the phylogenetic relationships among 4 species of the D. bipectinata complex.

  18. Genetic interactions underlying hybrid male sterility in the Drosophila bipectinata species complex.

    PubMed

    Mishra, Paras Kumar; Singh, Bashisth Narayan

    2006-06-01

    Understanding genetic mechanisms underlying hybrid male sterility is one of the most challenging problems in evolutionary biology especially speciation. By using the interspecific hybridization method roles of Y chromosome, Major Hybrid Sterility (MHS) genes and cytoplasm in sterility of hybrid males have been investigated in a promising group, the Drosophila bipectinata species complex that consists of four closely related species: D. pseudoananassae, D. bipectinata, D. parabipectinata and D. malerkotliana. The interspecific introgression analyses show that neither cytoplasm nor MHS genes are involved but X-Y interactions may be playing major role in hybrid male sterility between D. pseudoananassae and the other three species. The results of interspecific introgression analyses also show considerable decrease in the number of males in the backcross offspring and all males have atrophied testes. There is a significant positive correlation between sex - ratio distortion and severity of sterility in backcross males. These findings provide evidence that D. pseudoananassae is remotely related with other three species of the D. bipectinata species complex.

  19. Testing sterile neutrino extensions of the Standard Model at future lepton colliders

    NASA Astrophysics Data System (ADS)

    Antusch, Stefan; Fischer, Oliver

    2015-05-01

    Extending the Standard Model (SM) with sterile ("right-handed") neutrinos is one of the best motivated ways to account for the observed neutrino masses. We discuss the expected sensitivity of future lepton collider experiments for probing such extensions. An interesting testable scenario is given by "symmetry protected seesaw models", which theoretically allow for sterile neutrino masses around the electroweak scale with up to order one mixings with the light (SM) neutrinos. In addition to indirect tests, e.g. via electroweak precision observables, sterile neutrinos with masses around the electroweak scale can also be probed by direct searches, e.g. via sterile neutrino decays at the Z pole, deviations from the SM cross section for four lepton final states at and beyond the WW threshold and via Higgs boson decays. We study the present bounds on sterile neutrino properties from LEP and LHC as well as the expected sensitivities of possible future lepton colliders such as ILC, CEPC and FCC-ee (TLEP).

  20. Microbial Penetration of Muslin- and Paper-Wrapped Sterile Packs Stored on Open Shelves and in Closed Cabinets

    PubMed Central

    Standard, Paul G.; Mackel, Don C.; Mallison, G. F.

    1971-01-01

    Microbial penetration of sterile packs was studied using single-wrap (two layers) muslin, double-wrap (four layers) muslin, and two-way crepe paper (single layer) to wrap 20 gauze sponges (2 by 2 inch). These packs were stored in the central sterile supply departments of two hospitals and processed for sterility at predetermined intervals. Microorganisms penetrated single-wrap muslin as early as 3 days and double-wrap muslin and single-wrap two-way crepe paper in 21 to 28 days stored in open shelves. The time required for microbial penetration was at least twice as long when closed cabinets were used. Single-wrap muslin packs stored in sealed, impervious plastic bags remained sterile for at least 9 months. All sterile materials in pervious wrappers should be handled as little as possible and then only with extreme care and caution. Closed cabinets offer more protection than open shelves, and single wrappers are not recommended. Images PMID:5119207

  1. Feasibility study of the sterilization of pigskin used as wound dressings by neutral electrolyzed water.

    PubMed

    Ge, Liangpeng; Zhang, Xiaochun; Cao, Chuan; Gu, Zhaobin; Liu, Zuohua; Liu, Lubin; Lin, Baozhong

    2012-06-01

    Neutral electrolyzed water (NEW) is considered to be a high-level biodegradable disinfectant with sporicidal, bactericidal, and virucidal activity. It has also been reported to accelerate wound healing; thus, it is particularly attractive for the elimination or minimization of the microbial population of skin grafts to be used as wound dressings. Pigskins were sterilized with different concentrations of NEW and with different methods. The feasibility of pigskin sterilization by NEW was evaluated through microbiological analyses, viability assays, histologic assessments, contact cytotoxicity assays, and extract cytotoxicity assays. NEW has strong bactericidal effects on pigskin microorganisms, does not change skin graft histologic properties, and has no cytotoxicity; however, skin viability was significantly reduced after NEW treatment. Although NEW treatment is a very safe and effective method for nonviable pigskin dressing sterilization, to obtain a complete sterilization of pigskin grafts, available chlorine concentration of NEW as well as sterilization time and methods should be optimized. Copyright © 2012 by Lippincott Williams & Wilkins.

  2. Observations on female sterilization in Chile.

    PubMed

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical and paramedical health services personnel played a significant role in patients' decision to request sterilization. Few women cited mass media as playing a part. Pomeroy and laparoscopic methods were the most popular methods used in Valdivia, 53.8% of the Santiago women were sterilized by the Pomeroy method and the others by Madlener or other methods. Postoperative results of sterilization are divided into clinical problems, postoperative attitude of spouse, and sexual relations. Results indicate that there are no substantial differences between the contraceptive behavior of Catholics and non-Catholics. There is an apparent need for more family planning education in Chile as is evidenced by complications of contraceptive method use. The postoperative consequences of sterilization suggest the need for research and analysis.

  3. Intimate Partner Violence is Associated with Voluntary Sterilization in Women.

    PubMed

    McCloskey, Laura Ann; Doran, Kelly A; Gerber, Megan R

    2017-01-01

    Intimate partner violence (IPV) may interfere with women's use of preferred forms of contraception, resulting in unwanted pregnancies forcing women to seek permanent sterilization. A history of child sexual abuse (CSA) presages the risk for IPV in adulthood setting the stage for adverse reproductive outcomes. To determine whether CSA and IPV are associated with women's voluntary sterilization when adjusting for demographics and reproductive health history. This cross-sectional study is based on in-person interviews of women (N = 278) drawn from outpatients surveyed in more than 10 different clinics (N = 2465). Women's history of gender-based violence and bilateral tubal ligation (BTL) were assessed. About half of the women had a past history of IPV and 29% disclosed CSA. CSA predicted later entry into an abusive relationship (odds ratio [OR] = 6.7). Sterilization was reported by 19.6%. Parity (3+ children), having had an abortion, and receipt of welfare were associated with sterilization in univariate tests. Among those women receiving a BTL, 74% had violent partners. Adjusted multivariate logistic regressions, adjusted for demographics and reproductive history, indicated that having had an abusive partner increased the odds of sterilization; parity was also highly associated. CSA exerted only an indirect influence on sterilization via entry into violent relationships. IPV raises the likelihood that women will choose sterilization. Despite the importance of women's access to permanent contraception, priority should be given to screening for gender-based violence and promoting interventions.

  4. Non-coding RNAs and plant male sterility: current knowledge and future prospects.

    PubMed

    Mishra, Ankita; Bohra, Abhishek

    2018-02-01

    Latest outcomes assign functional role to non-coding (nc) RNA molecules in regulatory networks that confer male sterility to plants. Male sterility in plants offers great opportunity for improving crop performance through application of hybrid technology. In this respect, cytoplasmic male sterility (CMS) and sterility induced by photoperiod (PGMS)/temperature (TGMS) have greatly facilitated development of high-yielding hybrids in crops. Participation of non-coding (nc) RNA molecules in plant reproductive development is increasingly becoming evident. Recent breakthroughs in rice definitively associate ncRNAs with PGMS and TGMS. In case of CMS, the exact mechanism through which the mitochondrial ORFs exert influence on the development of male gametophyte remains obscure in several crops. High-throughput sequencing has enabled genome-wide discovery and validation of these regulatory molecules and their target genes, describing their potential roles performed in relation to CMS. Discovery of ncRNA localized in plant mtDNA with its possible implication in CMS induction is intriguing in this respect. Still, conclusive evidences linking ncRNA with CMS phenotypes are currently unavailable, demanding complementing genetic approaches like transgenics to substantiate the preliminary findings. Here, we review the recent literature on the contribution of ncRNAs in conferring male sterility to plants, with an emphasis on microRNAs. Also, we present a perspective on improved understanding about ncRNA-mediated regulatory pathways that control male sterility in plants. A refined understanding of plant male sterility would strengthen crop hybrid industry to deliver hybrids with improved performance.

  5. Effect of Repeated Sterilization Cycles on the Physical Properties of Scaling Instruments: A Scanning Electron Microscopy Study

    PubMed Central

    Porto, Alessandra Nogueira; Borges, Álvaro Henrique; Semenoff-Segundo, Alex; Raslan, Suzane A; Pedro, Fábio Luis Miranda; Jorge, Antônio Olavo Cardoso; Bandeca, Matheus Coelho

    2015-01-01

    Background: Repeated sterilizations cycles cause undesirable alterations in the material properties of the instruments, such as corrosion, alterations in the hardness of the metal and the loss of the cutting sharpness of the instrument. This research examined the effect of repeated dry heat sterilization and autoclaves cycles on carbon steel (CS) and stainless steel (SS) curettes during the scaling and root planning. Materials and Methods: A total of 77 Gracey curettes were used in this study. Of these, 35 were SS and 42 were CS curettes submitted in different process: Dry heat, autoclave, inhibition of corrosion and autoclave, scaling, root planning and dry heat, scaling, root planning, inhibition of corrosion and autoclave. The inhibition of corrosion used on the carbon curettes (prior to sterilization in the autoclave) was sodium nitrite at 2%. The curettes received 10 consecutive cycles of sterilization and after that the cutting edges were examined in the electronic microscope, at 60 and 100 magnification times. Results: The images were evaluated by three independent examiners, who compared the photographs of each group with the control group. Conclusion: The surface corrosion products and a deterioration of the edges were observed and the results showed that the SS curettes suffered little alteration with sterilization, scaling, root planning whereas the CS curettes were visibly affected by sterilization in the autoclave, but when the inhibition of corrosion was used prior to the sterilization, the oxidation was considerably reduced. PMID:26028893

  6. [The effect of autoclave sterilization on the surface properties of orthodontic brackets after fitting in the mouth].

    PubMed

    Rerhrhaye, W; Ouaki, B; Zaoui, F; Aalloula, E

    2011-12-01

    Repeated sterilizations of the orthodontic bands, after fitting in mouth, are likely to involve modifications of their surface properties. Through this study we have tried to observe the effect of sterilization by autoclave on the surface of the orthodontic bands, as well as the contribution of the use of ultrasound in the chain of sterilization. The sample was composed of 30 orthodontic bands divided into 5 groups: a group of new bands (witnesses) and 4 groups having undergone respectively 1 cycle, 3 cycles, 5 cycles and 7 cycles of autoclave sterilization according to the World Health Organization recommendations. For half of each group bands, ultrasonic cleaning has not been provided. The scanning electron microscopy with the elementary microanalysis by X-rays was used for the investigation of surface. At the exam, new bands showed surface irregularities probably due to manufacturing procedures. And the bands, without ultrasonic cleaning, showed the presence of contamination and discolourations. Moreover, there were no modifications on the surface of the bands cleaned by ultrasounds before sterilization. The presence of surface irregularities associated with deposits observed on the bands surface, may be the site of bio corrosion by contributing bio film accumulation. The stay duration of the orthodontic bands in mouth, during orthodontic treatment, is important. So the effect of sterilization on the surface of the orthodontic bands must encourage other scientific research to determine the long term effects of sterilization which remains an essential process in our daily practice.

  7. Comparative study of different techniques for the sterilization of poly-L-lactide electrospun microfibers: effectiveness vs. material degradation.

    PubMed

    Rainer, Alberto; Centola, Matteo; Spadaccio, Cristiano; Gherardi, Giovanni; Genovese, Jorge A; Licoccia, Silvia; Trombetta, Marcella

    2010-02-01

    Electrospinning of biopolymeric scaffolds is a new and effective approach for creating replacement tissues to repair defects and/or damaged tissues with direct clinical application. However, many hurdles and technical concerns regarding biological issues, such as cell retention and the ability to grow, still need to be overcome to gain full access to the clinical arena. Interaction with the host human tissues, immunogenicity, pathogen transmission as well as production costs, technical expertise, and good manufacturing and laboratory practice requirements call for careful consideration when aiming at the production of a material that is available off-the-shelf, to be used immediately in operative settings. The issue of sterilization is one of the most important steps for the clinical application of these scaffolds. Nevertheless, relatively few studies have been performed to systematically investigate how sterilization treatments may affect the properties of electrospun polymers for tissue engineering. This paper presents the results of a comparative study of different sterilization techniques applied to an electrospun poly-L-lactide scaffold: soaking in absolute ethanol, dry oven and autoclave treatments, UV irradiation, and hydrogen peroxide gas plasma treatment. Morphological and chemical characterization was coupled with microbiological sterility assay to validate the examined sterilization techniques in terms of effectiveness and modifications to the scaffold. The results of this study reveal that UV irradiation and hydrogen peroxide gas plasma are the most effective sterilization techniques, as they ensure sterility of the electrospun scaffolds without affecting their chemical and morphological features.

  8. The effect of gamma radiation on sterility and mating ability of brown planthopper, Nilaparvata lugens(Stål) in field cage

    NASA Astrophysics Data System (ADS)

    Limohpasmanee, W.; Kongratarpon, T.; Tannarin, T.

    2017-06-01

    The brown planthopper, Nilaparvata lugens(Stål) is the major rice pest in Thailand. Adults and nymphs suck the sap from the rice plant causing it to wilt and transmitting the grassy stunt and the ragged stunt diseases. The population suppression by the sterile insect technique is overwhelmingly a function of mating between sterile males and wild females. The objectives of these experiments were to determine the suitable dose which induces partially sterile in N. lugens and their effect on wild population in the field cages. One-day-old 4th and 5th instar nymphs and adults were irradiated in a 60Co irradiator at the doses of 30, 60, 90 and 120 Gy. It was found that irradiation at the dose of 90 Gy induced complete sterility in female and 78.47 % sterility in males. The inherited sterility were transferred to their progenies and induced 51.46 and 77.00 % sterility in F-1 males and females. The irradiation as the mention dose did not affect mating ability. The competitiveness index was increased when the ratio of irradiated males per normal male was increased. The releasing irradiated males at 10 fold of normal males in field cages could suppress F-1 population 80.11 % and suppress F-2 population 80.32 % when compare with the control. This technique may be applied to delay and/or reduce seasonal increase of brown planthopper.

  9. Parents' Attitudes toward Sterilization of Their Mentally Retarded Children.

    ERIC Educational Resources Information Center

    Wolf, Lucille; Zarfas, Donald E.

    1982-01-01

    One hundred fifty-seven parents' attitudes toward sterilization and the sexuality of their retarded offspring were identified. Parent and child characteristics associated with these attitudes were investigated. Findings indicated that parents substantially concurred with the principle of sterilization (71 percent for involuntary, 67 percent for…

  10. 77 FR 43086 - Agency Information Collection Request; 60-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    ...; Sterilization of Persons in Federally Assisted Family Planning Projects--OMB No. 0937- 0166--Extension--OPHS..., subpart B (``Sterilization of Persons in Federally Assisted Family Planning Projects''). The consent form solicits information to assure voluntary and informed consent to persons undergoing sterilization in...

  11. Sterilization of Extracted Human Teeth.

    ERIC Educational Resources Information Center

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  12. Soft-tissue allografts terminally sterilized with an electron beam are biomechanically equivalent to aseptic, nonsterilized tendons.

    PubMed

    Elenes, Egleide Y; Hunter, Shawn A

    2014-08-20

    Allograft safety is contingent on effective sterilization. However, current sterilization methods have been associated with decreased biomechanical strength and higher failure rates of soft-tissue allografts. In this study, electron beam (e-beam) sterilization was explored as an alternative sterilization method to preserve biomechanical integrity. We hypothesized that e-beam sterilization would not significantly alter the biomechanical properties of tendon allograft compared with aseptic, nonsterilized controls and gamma-irradiated grafts. Separate sets of forty fresh-frozen tibialis tendon allografts (four from each of ten donors) and forty bisected bone-patellar tendon-bone (BTB) allografts (four from each of ten donors) were randomly assigned to four study groups. One group received a 17.1 to 21.0-kGy gamma radiation dose; two other groups were sterilized with an e-beam at either a high (17.1 to 21.0-kGy) or low (9.2 to 12.2-kGy) dose. A fourth group served as nonsterilized controls. Each graft was cyclically loaded to 200 N of tension for 2000 cycles at a frequency of 2 Hz, allowed to relax for five minutes, and then tested in tension until failure at a 100%/sec strain rate. One-way analysis of variance testing was used to identify significant differences. Tibialis tendons sterilized with both e-beam treatments and with gamma irradiation exhibited values for cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus that were not significantly different from those of nonsterilized controls. BTB allografts sterilized with the high e-beam dose and with gamma irradiation were not significantly different in cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus from nonsterilized controls. BTB allografts sterilized with the e-beam at the lower dose were significantly less stiff than nonsterilized controls (p = 0.014) but did not differ from controls in any other properties. The difference in stiffness likely resulted from variations in tendon size rather than the treatments, as the elastic moduli of the groups were similar. The biomechanical properties of tibialis and BTB allografts sterilized with use of an e-beam at a dose range of 17.1 to 21.0 kGy were not different from those of aseptic, nonsterilized controls or gamma-irradiated allografts. E-beam sterilization can be a viable method to produce safe and biomechanically uncompromised soft-tissue allografts. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  13. 78 FR 20658 - Agency Information Collection Activities; Proposed Collection; Comment Request; Agreement for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-05

    ... Devices for Sterilization AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and... of information technology. Agreement for Shipment of Devices for Sterilization--21 CFR 801.150(e... commerce for sterilization at another establishment, a practice that facilitates the processing of devices...

  14. Husband-Wife Communication, Wife's Employment, and the Decision for Male or Female Sterilization.

    ERIC Educational Resources Information Center

    Bean, Frank D.; And Others

    1983-01-01

    Examined relationships between perceptions of marital communication and the choice of male or female sterilization in 313 couples. The wife's perception of marital communication was negatively related to the tendency for the couple to choose female sterilization, conditional on female labor force participation. Communication questions are…

  15. Sterilization Anxiety and Fertility Control in the Later Years of Childbearing.

    ERIC Educational Resources Information Center

    Groat, H. Theodore; And Others

    1990-01-01

    Examined anxiety surrounding sterilization decision making, using data from 338 couples with completed childbearing, almost evenly divided between those who were sterilized and those who were not. Separate factor analyses for husbands and wives revealed 3 distinct dimensions of anxiety. Anxiety factors were highly predictive of sterilization…

  16. Sociodemographic and Marital Heterogamy Influences on the Decision for Voluntary Sterilization.

    ERIC Educational Resources Information Center

    Bean, Frank D.; And Others

    1987-01-01

    Examined relationships between religious and age heterogamy and choice of voluntary contraceptive sterilization and decision for male or female procedure. Found that couples of disparate ages and mixed-faith marriages exhibited greater tendency to elect sterilization than did other couples. No relationship emerged between measures of heterogamy…

  17. Issues in Fertility Control for Mentally Retarded Female Adolescents: II. Parental Attitudes toward Sterilization.

    ERIC Educational Resources Information Center

    Passer, Alice; And Others

    1984-01-01

    Interviews with 69 parents of mentally retarded adolescents revealed that 46 percent had considered sterilization for their daughters. Interest in sterilization especially correlated with increased severity of retardation and with difficulty teaching menstrual hygiene. Few parents supported either an extremely restrictive or permissive position.…

  18. 75 FR 7276 - Agency Information Collection Activities; Proposed Collection; Comment Request; Agreement for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-18

    ... Devices for Sterilization AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and... for Sterilization--21 CFR 801.150(e) (OMB Control Number 0910-0131)--Extension Under sections 501(c... and ship the devices in interstate commerce for sterilization at another establishment, a practice...

  19. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  20. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  1. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  2. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  3. 21 CFR 800.10 - Contact lens solutions; sterility.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  4. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    USDA-ARS?s Scientific Manuscript database

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  5. 7 CFR 305.28 - Kiln sterilization treatment schedule.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Kiln sterilization treatment schedule. 305.28 Section... INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.28 Kiln sterilization treatment schedule. T404-b-4 Dry bulb temperature( °F) Wet bulb depression( °F) Percent...

  6. Are biting fly larvae biological reservoirs of Salmonella?

    USDA-ARS?s Scientific Manuscript database

    A Salmonella Montevideo strain that is resistant to ampicillin and kanamycin and that expresses the green fluorescent protein (S Montevideo-GFP) was utilized to inoculate sterile and non-sterile cattle manure (1 x 105 CFU/gram manure) onto which sterilized horn fly embryos were placed and held for e...

  7. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent...

  8. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent...

  9. 21 CFR 522.88 - Sterile amoxicillin trihydrate for suspension.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.88 Sterile amoxicillin trihydrate for suspension. (a)(1) Specifications. Each vial... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Sterile amoxicillin trihydrate for suspension. 522...

  10. 21 CFR 522.88 - Sterile amoxicillin trihydrate for suspension.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.88 Sterile amoxicillin trihydrate for suspension. (a)(1) Specifications. Each vial... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Sterile amoxicillin trihydrate for suspension. 522...

  11. 21 CFR 522.88 - Sterile amoxicillin trihydrate for suspension.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.88 Sterile amoxicillin trihydrate for suspension. (a)(1) Specifications. Each vial... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile amoxicillin trihydrate for suspension. 522...

  12. 21 CFR 522.88 - Sterile amoxicillin trihydrate for suspension.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.88 Sterile amoxicillin trihydrate for suspension. (a)(1) Specifications. Each vial... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Sterile amoxicillin trihydrate for suspension. 522...

  13. Medicaid Consent to Sterilization forms: historical, practical, ethical, and advocacy considerations.

    PubMed

    Block-Abraham, Dana; Arora, Kavita S; Tate, Danielle; Gee, Rebekah E

    2015-06-01

    The US government developed a Medicaid Consent to Sterilization form in the mid-1970s to protect vulnerable populations from coerced sterilization. US health care practices have evolved significantly since that time. The form, however, has not changed, and may be preventing access to desired services for the same vulnerable populations it was originally created to protect. This paper discusses the relevant historical, practical use, ethical, and advocacy considerations of the Medicaid sterilization consent form and proposes changes to make the form more pertinent to today's medical environment.

  14. The search for sterile neutrinos with SOX-Borexino

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Altenmüller, K., E-mail: konrad.altenmueller@ph.tum.de; Agostini, M.; Appel, S.

    2016-12-15

    The aim of the SOX-Borexino project is to verify or falsify the existence of eV-scale sterile neutrinos. The existence of sterile neutrinos is suspected because of several anomalies, which were observed in previous experiments. A ~3.7 PBq electron antineutrino source made of {sup 144}Ce will be installed below the Borexino detector at LNGS, Italy, to search for short-baseline oscillations of active-to-sterile neutrinos within the detector volume. Source delivery and beginning of data acquisition is planned for end of 2016, preliminary results are expected already in 2017.

  15. Bacterial Spores Survive Treatment with Commercial Sterilants and Disinfectants

    PubMed Central

    Sagripanti, Jose-Luis; Bonifacino, Aylin

    1999-01-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged. PMID:10473448

  16. Bacterial spores survive treatment with commercial sterilants and disinfectants.

    PubMed

    Sagripanti, J L; Bonifacino, A

    1999-09-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged.

  17. Adventures in the Environmental World and Environmental Microbiology Sampling of Air for Pharmaceutical Sterile Compounding.

    PubMed

    Ligugnana, Roberto

    2017-01-01

    Chapter <797> issued by the United States Pharmacopeial Convention, Inc. is the standard for sterile compounding. It is designed to reduce the number of patient infections due to contaminated pharmaceutical preparation. This regulation applies to all staff who prepare compounded sterile preparations and all places where they are produced, including hospitals, clinics, pharmacies, and physician's offices. This article provides the history of environmental microbiology and provides a discussion on environmental microbiology sampling of air for pharmaceutical sterile compounding. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  18. The search for sterile neutrinos with SOX-Borexino

    NASA Astrophysics Data System (ADS)

    Altenmüller, K.; Agostini, M.; Appel, S.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Cavalcante, P.; Chepurnov, A.; Cribier, M.; D'Angelo, D.; Davini, S.; Derbin, A.; di Noto, L.; Drachnev, I.; Durero, M.; Empl, A.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Göger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jonqures, N.; Kaiser, M.; Kobychev, V.; Korablev, D.; Korga, G.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Papp, L.; Perasso, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Roncin, R.; Romani, A.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Simgen, H.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Toropova, M.; Unzhakov, E.; Veyssière, C.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2016-12-01

    The aim of the SOX-Borexino project is to verify or falsify the existence of eV-scale sterile neutrinos. The existence of sterile neutrinos is suspected because of several anomalies, which were observed in previous experiments. A 3.7 PBq electron antineutrino source made of 144Ce will be installed below the Borexino detector at LNGS, Italy, to search for short-baseline oscillations of active-to-sterile neutrinos within the detector volume. Source delivery and beginning of data acquisition is planned for end of 2016, preliminary results are expected already in 2017.

  19. Female sterilization in Thailand: past, present and future.

    PubMed

    Intaraprasert, S; Chaturachinda, K

    1993-01-01

    Female sterilization is the most effective contraception and has a very high demographic effectiveness. In the past, there have been developments in technological aspects. At present, the minilaparotomy and laparoscopic sterilization have been well developed and widely used, but the number of new acceptors is declining, and there is still a large number of unmet demands. Social action rather than technological action is needed. In the future, steps to increase the number of acceptors, are, proper management of the sterilization services, including adequate monitoring and a good surveillance system.

  20. Coherent Active-Sterile Neutrino Flavor Transformation in the Early Universe

    NASA Astrophysics Data System (ADS)

    Kishimoto, Chad T.; Fuller, George M.; Smith, Christel J.

    2006-10-01

    We solve the problem of coherent Mikheyev-Smirnov-Wolfenstein resonant active-to-sterile neutrino flavor conversion driven by an initial lepton number in the early Universe. We find incomplete destruction of the lepton number in this process and a sterile neutrino energy distribution with a distinctive cusp and high energy tail. These features imply alteration of the nonzero lepton number primordial nucleosynthesis paradigm when there exist sterile neutrinos with rest masses ms˜1eV. This could result in better light element probes of (constraints on) these particles.

Top