PERFORMANCE OF OVID MEDLINE SEARCH FILTERS TO IDENTIFY HEALTH STATE UTILITY STUDIES.
Arber, Mick; Garcia, Sonia; Veale, Thomas; Edwards, Mary; Shaw, Alison; Glanville, Julie M
2017-01-01
This study was designed to assess the sensitivity of three Ovid MEDLINE search filters developed to identify studies reporting health state utility values (HSUVs), to improve the performance of the best performing filter, and to validate resulting search filters. Three quasi-gold standard sets (QGS1, QGS2, QGS3) of relevant studies were harvested from reviews of studies reporting HSUVs. The performance of three initial filters was assessed by measuring their relative recall of studies in QGS1. The best performing filter was then developed further using QGS2. This resulted in three final search filters (FSF1, FSF2, and FSF3), which were validated using QGS3. FSF1 (sensitivity maximizing) retrieved 132/139 records (sensitivity: 95 percent) in the QGS3 validation set. FSF1 had a number needed to read (NNR) of 842. FSF2 (balancing sensitivity and precision) retrieved 128/139 records (sensitivity: 92 percent) with a NNR of 502. FSF3 (precision maximizing) retrieved 123/139 records (sensitivity: 88 percent) with a NNR of 383. We have developed and validated a search filter (FSF1) to identify studies reporting HSUVs with high sensitivity (95 percent) and two other search filters (FSF2 and FSF3) with reasonably high sensitivity (92 percent and 88 percent) but greater precision, resulting in a lower NNR. These seem to be the first validated filters available for HSUVs. The availability of filters with a range of sensitivity and precision options enables researchers to choose the filter which is most appropriate to the resources available for their specific research.
Liu, Dehua; Chan, Ben Chung-Lap; Cheng, Ling; Tsang, Miranda Sin-Man; Zhu, Jing; Wong, Chun-Wai; Jiao, Delong; Chan, Helen Yau-Tsz; Leung, Ping Chung; Lam, Christopher Wai-Kei; Wong, Chun Kwok
2018-03-02
The immune system responds to Mycobacterium tuberculosis (MTB) infection by forming granulomas to quarantine the bacteria from spreading. Granuloma-mediated inflammation is a cause of lung destruction and disease transmission. Sophora flavescens (SF) has been demonstrated to exhibit bactericidal activities against MTB. However, its immune modulatory activities on MTB-mediated granulomatous inflammation have not been reported. In the present study, we found that flavonoids from Sophora flavescens (FSF) significantly suppressed the pro-inflammatory mediators released from mouse lung alveolar macrophages (MH-S) upon stimulation by trehalose dimycolate (TDM), the most abundant lipoglycan on MTB surface. Moreover, FSF reduced adhesion molecule (LFA-1) expression on MH-S cells after TDM stimulation. Furthermore, FSF treatment on TDM-activated lung epithelial (MLE-12) cells significantly downregulated macrophage chemoattractant protein (MCP-1/CCL2) expression, which in turn reduced the in vitro migration of MH-S to MLE-12 cells. In addition, FSF increased the clearance of mycobacterium bacteria (Mycobacterium aurum) in macrophages. FSF mainly affected the Mincle-Syk-Erk signaling pathway in TDM-activated MH-S cells. In TDM-induced mouse granulomas model, oral administration with FSF significantly suppressed lung granulomas formation and inflammation. These findings collectively implicated an anti-inflammatory role of FSF on MTB-mediated granulomatous inflammation, thereby providing evidence of FSF as an efficacious adjunct treatment during mycobacterial infection.
Cleaning residual NaK in the fast flux test facility fuel storage cooling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, T.M.; Church, W.R.; Hodgson, K.M.
2008-01-15
The Fast Flux Test Facility (FFTF), located on the U.S. Department of Energy's Hanford Reservation, is a liquid metal-cooled test reactor. The FFTF was constructed to support the U.S. Liquid Metal Fast Breeder Reactor Program. The bulk of the alkali metal (sodium and NaK) has been drained and will be stored onsite prior to final disposition. Residual NaK needed to be removed from the pipes, pumps, heat exchangers, tanks, and vessels in the Fuel Storage Facility (FSF) cooling system. The cooling system was drained in 2004 leaving residual NaK in the pipes and equipment. The estimated residual NaK volume wasmore » 76 liters in the storage tank, 1.9 liters in the expansion tank, and 19-39 liters in the heat transfer loop. The residual NaK volume in the remainder of the system was expected to be very small, consisting of films, droplets, and very small pools. The NaK in the FSF Cooling System was not radiologically contaminated. The portions of the cooling system to be cleaned were divided into four groups: 1. The storage tank, filter, pump, and associated piping; 2. The heat exchanger, expansion tank, and associated piping; 3. Argon supply piping; 4. In-vessel heat transfer loop. The cleaning was contracted to Creative Engineers, Inc. (CEI) and they used their superheated steam process to clean the cooling system. It has been concluded that during the modification activities (prior to CEI coming onsite) to prepare the NaK Cooling System for cleaning, tank T-914 was pressurized relative to the In-Vessel NaK Cooler and NaK was pushed from the tank back into the Cooler and that on November 6, 2005, when the gas purge through the In-Vessel NaK Cooler was increased from 141.6 slm to 283.2 slm, NaK was forced from the In-Vessel NaK Cooler and it contacted water in the vent line and/or scrubber. The gases from the reaction then traveled back through the vent line coating the internal surface of the vent line with NaK and NaK reaction products. The hot gases also exited the scrubber through the stack and due to the temperature of the gas, the hydrogen auto ignited when it mixed with the oxygen in the air. There was no damage to equipment, no injuries, and no significant release of hazardous material. Even though the FSF Cooling System is the only system at FFTF that contains residual NaK, there are lessons to be learned from this event that can be applied to future residual sodium removal activities. The lessons learned are: - Before cleaning equipment containing residual alkali metal the volume of alkali metal in the equipment should be minimized to the extent practical. As much as possible, reconfirm the amount and location of the alkali metal immediately prior to cleaning, especially if additional evolutions have been performed or significant time has passed. This is especially true for small diameter pipe (<20.3 centimeters diameter) that is being cleaned in place since gas flow is more likely to move the alkali metal. Potential confirmation methods could include visual inspection (difficult in all-metal systems), nondestructive examination (e.g., ultrasonic measurements) and repeating previous evolutions used to drain the system. Also, expect to find alkali metal in places it would not reasonably be expected to be. - Staff with an intimate knowledge of the plant equipment and the bulk alkali metal draining activities is critical to being able to confirm the amount and locations of the alkali metal residuals and to safely clean the residuals. - Minimize the potential for movement of alkali metal during cleaning or limit the distance and locations into which alkali metal can move. - Recognize that when working with alkali metal reactions, occasional pops and bangs are to be anticipated. - Pre-plan emergency responses to unplanned events to assure responses planned for an operating reactor are appropriate for the deactivation phase.« less
Active Flexural-Slip Faulting: Controls Exerted by Stratigraphy, Geometry, and Fold Kinematics
NASA Astrophysics Data System (ADS)
Li, Tao; Chen, Jie; Thompson Jobe, Jessica A.; Burbank, Douglas W.
2017-10-01
Flexural slip plays an important role in accommodating fold growth, and its topographic expression, flexural-slip fault (FSF) scarps, may be one of the most commonly occurring secondary structures in areas dominated by active thrusts and folds. Where FSF scarps are present and what factors control their occurrence, however, are typically poorly known. Through an investigation of clearly expressed FSF scarps, well-preserved fluvial terraces, and well-exposed bedrock at eight sites in the Pamir-Tian Shan convergent zone and Kuche fold belt, NW China, we summarize the most favorable conditions for active flexural-slip faulting. Our study yields six key results. First, flexural slip operates commonly in well-layered beds, although uncommonly can occur in massive, poorly layered beds as well. Second, in well-layered beds, the slip surface is commonly located either (a) close to the contact of competent and incompetent beds or (b) within thin incompetent beds. Third, FSF scarps are always found overlying steep beds with dips of 30-100°. Fourth, slip surfaces are typically spaced between 10 and 440 m but can reach up to 600 m. Fifth, FSF scarps at most sites can be observed far away from the hinge-migrated fold scarps, suggesting that compared to hinge migration, limb rotation is generally required to accumulate flexural slip and produce associated topographic scarps. Finally, a higher regional convergent rate seems to facilitate the creation of FSF scarps more often than lower rates, whereas well-preserved, old terraces capped by thin deposits are more likely to record FSF scarps than unevenly preserved, young terraces with thick sedimentary caps.
Influence of monte carlo variance with fluence smoothing in VMAT treatment planning with Monaco TPS.
Sarkar, B; Manikandan, A; Nandy, M; Munshi, A; Sayan, P; Sujatha, N
2016-01-01
The study aimed to investigate the interplay between Monte Carlo Variance (MCV) and fluence smoothing factor (FSF) in volumetric modulated arc therapy treatment planning by using a sample set of complex treatment planning cases and a X-ray Voxel Monte Carlo-based treatment planning system equipped with tools to tune fluence smoothness as well as MCV. The dosimetric (dose to tumor volume, and organ at risk) and physical characteristic (treatment time, number of segments, and so on) of a set 45 treatment plans for all combinations of 1%, 3%, 5% MCV and 1, 3, 5 FSF were evaluated for five carcinoma esophagus cases under the study. Increase in FSF reduce the treatment time. Variation of MCV and FSF gives a highest planning target volume (PTV), heart and lung dose variation of 3.6%, 12.8% and 4.3%, respectively. The heart dose variation was highest among all organs at risk. Highest variation of spinal cord dose was 0.6 Gy. Variation of MCV and FSF influences the organ at risk (OAR) doses significantly but not PTV coverage and dose homogeneity. Variation in FSF causes difference in dosimetric and physical parameters for the treatment plans but variation of MCV does not. MCV 3% or less do not improve the plan quality significantly (physical and clinical) compared with MCV greater than 3%. The use of MCV between 3% and 5% gives similar results as 1% with lesser calculation time. Minimally detected differences in plan quality suggest that the optimum FSF can be set between 3 and 5.
Psychometric Evaluation of the PROMIS Fatigue-Short Form Across Diverse Populations
Ameringer, Suzanne; Elswick, R. K.; Menzies, Victoria; Robins, Jo Lynne; Starkweather, Angela; Walter, Jeanne; Gentry, Amanda Elswick; Jallo, Nancy
2016-01-01
Background The need for reliable, valid tools to measure patient-reported outcomes (PROs) is critical for both research and for evaluating treatment effects in practice. The Patient Reported Outcome Measurement Information System (PROMIS) Fatigue-Short Form v1.0 –Fatigue 7a (PROMIS F-SF) has had limited psychometric evaluation in various populations. Objectives The aim of the study is to examine psychometric properties of PROMIS F-SF item responses across various populations. Methods Data from five studies with common data elements were used in this secondary analysis. Samples from patients with fibromyalgia, sickle cell disease, cardiometabolic risk, pregnancy, and healthy controls were used. Reliability was estimated using Cronbach’s alpha. Dimensionality was evaluated with confirmatory factor analysis. Concurrent validity was evaluated by examining Pearson’s correlations between scores from the PROMIS F-SF, the Multidimensional Fatigue Symptom Inventory-Short Form (MFSI-SF), and the Brief Fatigue Inventory (BFI). Discriminant validity was evaluated by examining Pearson’s correlations between scores on the PROMIS F-SF and measures of stress and depressive symptoms. Known groups validity was assessed by comparing PROMIS F-SH scores in the clinical samples to healthy controls. Results Reliability of PROMIS F-SF scores was adequate across samples, ranging from .72 in the pregnancy sample to .88 in healthy controls. Unidimensionality was supported in each sample. Concurrent validity was strong; across the groups, correlations with scores on the MFSI-SF and BFI ranged from .60–.85. Correlations of the PROMIS-SF with measures of stress and depressive mood were moderate to strong, ranging from .37–.64. PROMIS F-SF scores were significantly higher in clinical samples, compared to healthy controls. Discussion Reliability and validity of the PROMIS F-SF were acceptable. The PROMIS F-SF is a suitable measure of fatigue across the four diverse clinical populations included in the analysis. PMID:27362514
NASA Astrophysics Data System (ADS)
Hasegawa, Yutaka; Asayama, Shinichiro; Harada, Ryohei; Tokuda, Kazuki; Kimura, Kimihiro; Ogawa, Hideo; Onishi, Toshikazu
2017-12-01
A new sideband separation method was developed for use in millimeter-/submillimeter-band radio receivers using a novel waveguide frequency separation filter (FSF), which consists of two branch line hybrid couplers and two waveguide high-pass filters. The FSF was designed to allow the radio frequency (RF) signal to pass through to an output port when the frequency is higher than a certain value (225 GHz), and to reflect the RF signal back to another output port when the frequency is lower. The FSF is connected to two double sideband superconductor-insulator-superconductor (SIS) mixers, and an image rejection ratio (IRR) is determined by the FSF characteristics. With this new sideband separation method, we can achieve good and stable IRR without the balancing two SIS mixers such as is necessary for conventional sideband-separating SIS mixers. To demonstrate the applicability of this method, we designed and developed an FSF for simultaneous observations of the J = 2-1 rotational transition lines of three CO isotopes (12CO, 13CO, and C18O): the 12CO line is in the upper sideband and the others are in the lower sideband with an intermediate-frequency range of 4-8 GHz at the radio frequency of 220/230 GHz. This FSF was then installed in the receiver system of the 1.85 m radio telescope of Osaka Prefecture University, and was used during the 2014 observation season. The observation results indicate that the IRR of the proposed receiver is 25 dB or higher for the 12CO line, and no significant fluctuation larger than 1 dB in the IRR was observed throughout the season. These results demonstrate the practical utility of the FSF receiver for observations like extensive molecular cloud surveys in specified lines with a fixed frequency setting.
Yokoo, Takeshi; Collins, Julie M; Hanna, Robert F; Bydder, Mark; Middleton, Michael S; Sirlin, Claude B
2008-07-01
To assess the effects of intravenous gadolinium (Gd) and flip angle (FA) on liver fat quantification by opposed-phase (OP) and in-phase (IP) imaging. Our Institutional Review Board (IRB) approved this Health Insurance Portability and Accountability Act (HIPAA)-compliant, retrospective, clinical study. We identified 79 patients in whom abdominal OP and IP gradient-echoes were obtained at 1.5T before and after Gd administration. All 79 patients were imaged at high FA (> or =70 degrees ); 57 were also imaged at low FA (< or =20 degrees ). Fat signal fraction (FSF) was calculated from pre- and post-Gd liver images for each subject and FA using the formula, FSF = (S(IP) - S(OP))/2S(IP), where S(IP) and S(OP) are the OP and IP signal intensities, respectively. The dataset pairs (pre-Gd vs. post-Gd; high-FA vs. low-FA) were compared using linear regression analysis. Before Gd, FSF was significantly greater at high FA than at low FA, with regression parameters (slope/intercept) of 1.27*/0.02*, where * indicates P value <0.01. After Gd, FSF was similar at high and low FA (0.99/-0.00). Gd administration caused an FA-dependent reduction in FSF, larger at high FA (0.68*/-0.03*) than at low FA (0.94, -0.01*). FSF by OP-IP imaging is highly dependent on FA before Gd, but this dependency is eliminated after administration of Gd. Gd appears to minimize the effect of T1-weighting and may improve the accuracy of liver fat quantification. (c) 2008 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Masudy-Panah, Saeid; Radhakrishnan, K.; Ru, Tan Hui; Yi, Ren; Wong, Ten It; Dalapati, Goutam Kumar
2016-09-01
Aluminum-doped cupric oxide (CuO:Al) was prepared via an out-diffusion process of Al from an Al-coated substrate into the deposited CuO thin film upon thermal treatment. The effect of the annealing temperature on the structural and optical properties of CuO:Al was investigated in detail. The influence of Al incorporation on the photovoltaic properties was then investigated by preparing a p-CuO:Al/n-Si heterojunction solar cell. A significant improvement in the performance of the solar cell was achieved by controlling the out-diffusion of Al. A novel in situ method to co-dope CuO with Al and titanium (Ti) has been proposed to demonstrate CuO-based solar cells with the front surface field (FSF) design. The FSF design was created by depositing a CuO:Al layer followed by a Ti-doped CuO (CuO:Ti) layer. This is the first successful experimental demonstration of the codoping of a CuO thin film and CuO thin film solar cells with the FSF design. The open circuit voltage (V oc), short circuit current density (J sc) and fill factor (FF) of the fabricated solar cells were significantly higher for the FSF device compared to devices without FSF. The FF of this device improved by 68% through the FSF design and a record efficiency ɳ of 2% was achieved. The improvement of the solar cell properties is mainly attributed to the reduction of surface recombination, which influences the charge carrier collection.
Mirdita, V; Dhillon, B S; Geiger, H H; Miedaner, T
2008-12-01
Ergot (Claviceps purpurea [Fr.] Tul.) is a serious disease of rye (Secale cereale L.) and it adversely affects the quality of grain. The present investigation was undertaken to study genotypic variability among full-sib families (FSF) of five open-pollinated (OP) winter rye populations of highly diverse origin, namely Dankovskie Selekcyine (Poland), Charkovskaja (Ukraine), NEM4 (Russia), Halo and Carokurz, both from Germany. About 50 FSF were developed at random in each population, and the FSF of each population were evaluated in separate but adjacent experiments conducted in four environments under artificial inoculation. A mixture of conidia of C. purpurea isolates was sprayed thrice during the flowering period. The materials were manually harvested at yellow-ripe stage. Resistance trait recorded was disease severity, i.e. percent ergot sclerotia in grain by weight. Mean ergot severity ranged from 2.29 to 4.08% for the five populations across environments. Significant genotypic variation (P < 0.01) due to FSF and FSF x environment interaction was observed within each population. Genotypic variation within all populations was higher than that among five populations. All populations showed high estimates of heritability (0.72-0.89). The study indicated that the evaluated OP populations are rich reservoirs of genetic variation that should also be used in hybrid breeding. Recurrent selection to further improve ergot resistance should be successful.
Local food protection and safety infrastructure and capacity: a Maryland case study.
Kufel, Joanna Zablotsky; Resnick, Beth A; Fox, Mary; Frattaroli, Shannon; Gielen, Andrea; Burke, Thomas A
2011-01-01
In Maryland, county Food Protection Programs (FPP), housed within Environmental Public Health (EPH) Divisions, maintain responsibility for regular inspection of all food service facilities (FSF). With growing concerns about how our food supply is protected, it is important to determine the state and effectiveness of our food safety systems. This research elucidates the roles, responsibilities, strengths, and weaknesses of Food Safety and Protection Programs in Maryland. A 16-question survey tool, which addressed facets of the local food protection infrastructure, including FSF inspections, staffing, budget, and foodborne illness surveillance, was distributed to all 24 county FPP. The number of FSF in Maryland increased 97% from 2001 to 2006 and counties had an average inspection completion rate of 73%, with a 4% increase over the time period. Statewide, there were 4.1 EPH full-time employees (FTE) per 10 000 population and 1.6 FPP FTE per 10 000 population. EPH Division budgets increased 63% statewide, from $19.5 million in 2000 to $31.9 million in 2007. FPP budgets also increased 59% over the period, from $6.2 million in 2000 to $9.8 million in 2007. This study offers new quantitative measures of the demands, capacities, and performance of Food Protection and Safety Programs in Maryland. This assessment of local EPH and FPP capacity also offers insight into the strengths and weaknesses of the local food protection and safety infrastructure. Importantly, it reveals an infrastructure and dedicated food protection workforce that inspects the food supply and responds to foodborne illness outbreaks. Yet, resources vary substantially from county to county, impacting which services can be provided and how well they can be performed. This can, in turn, impact the potential risk of foodborne illness and the public's overall health.
Gifford, Aliya; Walker, Ronald C.; Towse, Theodore F.; Brian Welch, E.
2015-01-01
Abstract. Beyond estimation of depot volumes, quantitative analysis of adipose tissue properties could improve understanding of how adipose tissue correlates with metabolic risk factors. We investigated whether the fat signal fraction (FSF) derived from quantitative fat–water magnetic resonance imaging (MRI) scans at 3.0 T correlates to CT Hounsfield units (HU) of the same tissue. These measures were acquired in the subcutaneous white adipose tissue (WAT) at the umbilical level of 21 healthy adult subjects. A moderate correlation exists between MRI- and CT-derived WAT values for all subjects, R2=0.54, p<0.0001, with a slope of −2.6, (95% CI [−3.3,−1.8]), indicating that a decrease of 1 HU equals a mean increase of 0.38% FSF. We demonstrate that FSF estimates obtained using quantitative fat–water MRI techniques correlate with CT HU values in subcutaneous WAT, and therefore, MRI-based FSF could be used as an alternative to CT HU for assessing metabolic risk factors. PMID:26702407
Graczyk, Thaddeus K.; Lucy, Frances E.; Tamang, Leena; Mashinski, Yessika; Broaders, Michael A.; Connolly, Michelle; Cheng, Hui-Wen A.
2009-01-01
Constructed subsurface flow (SSF) and free-surface flow (FSF) wetlands are being increasingly implemented worldwide into wastewater treatments in response to the growing need for microbiologically safe reclaimed waters, which is driven by an exponential increase in the human population and limited water resources. Wastewater samples from four SSF and FSF wetlands in northwestern Ireland were tested qualitatively and quantitatively for Cryptosporidium spp., Giardia duodenalis, and human-pathogenic microsporidia, with assessment of their viability. Overall, seven species of human enteropathogens were detected in wetland influents, vegetated areas, and effluents: Cryptosporidium parvum, C. hominis, C. meleagridis, C. muris, G. duodenalis, Encephalitozoon hellem, and Enterocytozoon bieneusi. SSF wetland had the highest pathogen removal rate (i.e., Cryptosporidium, 97.4%; G. duodenalis, 95.4%); however, most of these values for FSF were in the negative area (mean, −84.0%), meaning that more pathogens were discharged by FSF wetlands than were delivered to wetlands with incoming wastewater. We demonstrate here that (i) the composition of human enteropathogens in wastewater entering and leaving SSF and FSF wetlands is highly complex and dynamic, (ii) the removal and inactivation of human-pathogenic microorganisms were significantly higher at the SSF wetland, (iii) FSF wetlands may not always provide sufficient remediation for human enteropathogens, (iv) wildlife can contribute a substantial load of human zoonotic pathogens to wetlands, (v) most of the pathogens discharged by wetlands were viable, (vi) large volumes of wetland effluents can contribute to contamination of surface waters used for recreation and drinking water abstraction and therefore represent a serious public health threat, and (vii) even with the best pathogen removal rates achieved by SSF wetland, the reduction of pathogens was not enough for a safety reuse of the reclaimed water. To our knowledge, this is the first report of C. meleagridis from Ireland. PMID:19411413
Barth, Borna K; Fischer, Michael A; Kambakamba, Patryk; Lesurtel, Mickael; Reiner, Caecilia S
2016-04-01
To evaluate the use of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI)-derived fat- and liver function-measurements for prediction of future liver remnant (FLR) growth after portal vein occlusion (PVO) in patients scheduled for major liver resection. Forty-five patients (age, 59 ± 13.9 y) who underwent Gd-EOB-DTPA-enhanced liver MRI within 24 ± 18 days prior to PVO were included in this study. Fat-Signal-Fraction (FSF), relative liver enhancement (RLE) and corrected liver-to-spleen ratio (corrLSR) of the FLR were calculated from in- and out-of-phase (n=42) as well as from unenhanced T1-weighted, and hepatocyte-phase images (n=35), respectively. Kinetic growth rate (KGR, volume increase/week) of the FLR after PVO was the primary endpoint. Receiver operating characteristics analysis was used to determine cutoff values for prediction of impaired FLR-growth. FSF (%) showed significant inverse correlation with KGR (r=-0.41, p=0.008), whereas no significant correlation was found with RLE and corrLSR. FSF was significantly higher in patients with impaired FLR-growth than in those with normal growth (%FSF, 8.1 ± 9.3 vs. 3.0 ± 5.9, p=0.02). ROC-analysis revealed a cutoff-FSF of 4.9% for identification of patients with impaired FLR-growth with a specificity of 82% and sensitivity of 47% (AUC 0.71 [95%CI:0.54-0.87]). Patients with impaired FLR-growth according to the FSF-cutoff showed a tendency towards higher postoperative complication rates (posthepatectomy liver failure in 50% vs. 19%). Liver fat-content, but not liver function derived from Gd-EOB-DTPA-enhanced MRI is a predictor of FLR-growth after PVO. Thus, liver MRI could help in identifying patients at risk for insufficient FLR-growth, who may need re-evaluation of the therapeutic strategy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Resident education and training in female sexuality: results of a national survey.
Pancholy, Apurva B; Goldenhar, Linda; Fellner, Angela N; Crisp, Catrina; Kleeman, Steve; Pauls, Rachel
2011-02-01
Considering the prevalence of female sexual dysfunction, the lack of education and training in female sexual function and dysfunction (FSF&D) during and obstetrics and gynecology residency highlights a need for greater focus on this topic. To assess understanding and confidence among third and fourth year Ob/Gyn residents with respect to FSF&D. An Internet-based survey was constructed to evaluate third and fourth year residents in American Council for Graduate Medical Education-approved Ob/Gyn programs. Residents were asked about familiarity, knowledge, and confidence in treating various aspects of FSF&D, based on the Council on Resident Education in Obstetrics and Gynecology (CREOG) Educational Objectives for Ob/Gyn training. They were also queried regarding areas of improvement for their education. Responses to survey instrument. Two hundred thirty-four residents responded. The majority (91.5%) reported attending ≤5 didactic activities on FSF&D. Only 19.6% reported often or always screening women for sexual function problems; most had very little or no knowledge in administering or interpreting screening questionnaires. While many (82.8%) felt confident about obtaining a complete sexual history, only 54.7% felt able to perform a targeted physical exam. Although most residents had cared for women with dyspareunia (55.1%), a minority had managed many women with low desire (18.4%), arousal problems (8.1%), anorgasmia (5.6%), or vaginismus (16.7%). In treating patients, 34-56% reported rarely or never suggesting ancillary therapy such as counseling and medications. However, the majority believed that their confidence would increase through FSF&D lectures (97.9%), FSF&D patient observations (97.4%), rotating with a urogynecologist (94.4%), and online modules (90.6%). Despite CREOG requirements for Ob/Gyn training in female sexuality, most residents feel ill-equipped to address these problems. Additional evidence-based educational and didactic activities would enhance residents' knowledge and confidence in treating these common, quality-of-life issues. © 2010 International Society for Sexual Medicine.
Subgap transport in silicene-based superconducting hybrid structures
NASA Astrophysics Data System (ADS)
Li, Hai
2016-08-01
We investigate the influences of exchange field and perpendicular electric field on the subgap transport in silicene-based ferromagnetic/superconducting (FS) and ferromagnetic/superconducting/ferromagnetic (FSF) junctions. Owing to the unique buckling structure of silicene, the Andreev reflection and subgap conductance can be effectively modulated by a perpendicular electric field. It is revealed that the subgap conductance in the FS junction can be distinctly enhanced by an exchange field. Remarkably, resorting to the tunable band gap of silicene, an exclusive crossed Andreev reflection (CAR) process in the FSF junction can be realized within a wide range of related parameters. Moreover, in the FSF junction the exclusive CAR and exclusive elastic cotunneling processes can be switched by reversing the magnetization direction in one of the ferromagnetic regions.
Ghasimi, Dara S M; Tao, Yu; de Kreuk, Merle; Abbas, Ben; Zandvoort, Marcel H; van Lier, Jules B
2015-12-15
This study investigates the start-up and operation of bench-scale mesophilic (35 °C) and thermophilic (55 °C) anaerobic sequencing batch reactor (SBR) digesters treating the fine sieved fraction (FSF) from raw municipal sewage. FSF was sequestered from raw municipal wastewater, in the Netherlands, using a rotating belt filter equipped with a 350 micron mesh. For the given wastewater, the major component of FSF was toilet paper, which is estimated to be 10-14 kg per year per average person in the western European countries. A seven months adaptation time was allowed for the thermophilic and mesophilic digesters in order to adapt to FSF as the sole substrate with varying dry solids content of 10-25%. Different SBR cycle durations (14, 9 and 2 days) were applied for both temperature conditions to study methane production rates, volatile fatty acids (VFAs) dynamics, lag phases, as well as changes in microbial communities. The prevailing sludge in the two digesters consisted of very different bacterial and archaeal communities, with OP9 lineage and Methanothermobacter being pre-dominant in the thermophilic digester and Bacteroides and Methanosaeta dominating the mesophilic one. Eventually, decreasing the SBR cycle period, thus increasing the FSF load, resulted in improved digester performances, particularly with regard to the thermophilic digester, i.e. shortened lag phases following the batch feedings, and reduced VFA peaks. Over time, the thermophilic digester outperformed the mesophilic one with 15% increased volatile solids (VS) destruction, irrespective to lower species diversity found at high temperature. Copyright © 2015 Elsevier Ltd. All rights reserved.
Spread-F occurrences and relationships with foF2 and h'F at low- and mid-latitudes in China
NASA Astrophysics Data System (ADS)
Wang, Ning; Guo, Lixin; Zhao, Zhenwei; Ding, Zonghua; Lin, Leke
2018-04-01
Ionospheric irregularities are an important phenomenon in scientific studies and applications of radio-wave propagation. Spread-F echoes in ionograms are a type of high-frequency band irregularities that include frequency spread-F (FSF), range spread-F (RSF), and mixed spread-F (MSF) events. In this study, we obtained spread-F data from four ionosondes at low- and mid-latitudes near the 120°E chain in China during the 23rd solar cycle. We used these data to investigate spread-F occurrence percentages and variations with local time, season, latitude, and solar activity. The four ionosondes were located at Haikou (HK) (20°N, 110.34°E), Guangzhou (GZ) (23.14°N, 113.36°E), Beijing (BJ) (40.11°N, 116.28°E), and Changchun (CC) (43.84°N, 125.28°E). We also present possible correlations between spread-Fs and other ionospheric parameters, such as the critical frequency of the F2-layer (foF2) and the virtual height of the bottom-side F-layer (h'F). In particular, we investigated the possible threshold of the foF2 affecting the FSF and the relationship between the h'F and the RSF. The main conclusions are as follows: (a) the FSF occurrence percentages were anti-correlated with solar activity at all four sites; meanwhile, RSF occurrence rates increased with the increase in solar activity at HK, but not at the other three sites; (b) FSF occurrence rates were larger at the mid-latitudes than expected, while FSFs occurred more often after midnight; (c) the highest FSF occurrence rates mostly appeared during the summer months, while RSFs occurred mostly in the equinoctial months of 2000-2002 at HK and GZ; (d) a lower foF2 was suitable for FSF events; nevertheless, h'F and RSF occurrences satisfied the parabolic relationship; (e) the foF2 thresholds for FSFs were 15, 14, 7.6, and 7.8 MHz at HK, GZ, BJ, and CC, respectively. The h'Fs occurring between 240 and 290 km were more favorable for RSF occurrences. These results are important for understanding ionospheric irregularity variations in eastern Asia and for improving space weather modeling and forecasting capabilities[Figure not available: see fulltext.] .
Okpala, Laura; Okoli, Eric; Udensi, Emelem
2013-01-01
Cookies were produced from germinated pigeon pea, fermented sorghum, and cocoyam flour (CF) blends to determine their potentials in cookie manufacture. Ten flour formulations were produced and they were evaluated for their proximate and functional properties. Protein content ranged from 4.85% to 19.89% with 100% CF (100CF) having the least value, while 100% germinated pigeon pea flour (100GPF) had the highest value. Increase in levels of GPF to the flour blends resulted in increase in protein content of the blends. Cookies made with 100% fermented sorghum flour (100FSF) had the highest ash content of 2.73%, while cookies made with 100GPF had the least ash content. Energy values of the cookies ranged between 369.37 and 376.56 kcal/100 g, with cookie formulation 50%CF:50%FSF having the least value and cookies made with 16.7%CF:16.7%FSF:66.6GPF having the highest value. The control (cookies made with wheat) had the highest spread ratio of 24.13, while cookies made with 100FSF had the least spread ratio of 14.97. Cookies made with 100CF were the least fragile. Sensory ratings revealed that cookies containing up to 50% CF and above, compared favorably with those made with wheat flour.
Okpala, Laura; Okoli, Eric; Udensi, Emelem
2013-01-01
Cookies were produced from germinated pigeon pea, fermented sorghum, and cocoyam flour (CF) blends to determine their potentials in cookie manufacture. Ten flour formulations were produced and they were evaluated for their proximate and functional properties. Protein content ranged from 4.85% to 19.89% with 100% CF (100CF) having the least value, while 100% germinated pigeon pea flour (100GPF) had the highest value. Increase in levels of GPF to the flour blends resulted in increase in protein content of the blends. Cookies made with 100% fermented sorghum flour (100FSF) had the highest ash content of 2.73%, while cookies made with 100GPF had the least ash content. Energy values of the cookies ranged between 369.37 and 376.56 kcal/100 g, with cookie formulation 50%CF:50%FSF having the least value and cookies made with 16.7%CF:16.7%FSF:66.6GPF having the highest value. The control (cookies made with wheat) had the highest spread ratio of 24.13, while cookies made with 100FSF had the least spread ratio of 14.97. Cookies made with 100CF were the least fragile. Sensory ratings revealed that cookies containing up to 50% CF and above, compared favorably with those made with wheat flour. PMID:24804009
Ramírez-Iglesia, Lilido Nelson; Roman Bravo, Rafael María; Díaz de Ramirez, Adelina; Torres, Leandro J.
2014-01-01
The aim of this research was to compare two artificial insemination protocols (AIP): hormonal synchronization with fixed time artificial insemination (SC-FTAI) and the use of a table based on visual observation of estrus signs (VO) in order to identify cows in natural or spontaneous estrus being assigned to AI (NSE-IA). Two groups were formed: in the first group 109 cows were assigned to SC-FTAI, in which a commercial protocol is used; the second one included 108 randomly chosen cows, which were assigned to NSE-AI and in this group a modified table was used. Response variable was first service fertility rate (FSF), which was coded 1 for pregnant and 0 for empty. Predictor variables were AIP, postpartum anestrus, daily milk yield, body condition score at AI and calving number. Statistical analyses included association chi-square tests and logistic regression. Results showed an overall 41.94% FSF and a significant association was detected (P < 0.05) between FSF and daily milk yield; pregnancy rates were 42.20% and 41.67% for the SC-FTAI and NSE-IA groups, respectively (P > 0.05). The odds ratio for the effect of AIP was only 1.050, suggesting no differences in FSF between groups. The NSE-AI protocol can enhance both the technique of VO and reproductive efficiency. Further validation of the table is required. PMID:26464929
NASA Astrophysics Data System (ADS)
Ong, Henry H.; Webb, Corey D.; Gruen, Marnie L.; Hasty, Alyssa H.; Gore, John C.; Welch, E. B.
2015-03-01
In obesity, fat-water MRI (FWMRI) methods provide valuable information about adipose tissue (AT) distribution. AT is known to undergo complex metabolic and endocrine changes in association with chronic inflammation including iron overloading. Here, we investigate the potential for FWMRI parameters (fat signal fraction (FSF), local magnetic field offset, and T2*) to be sensitive to AT inflammatory changes in an established diet-induced obesity mouse model. Male C57BL/6J mice were placed on a low fat (LFD) or a high fat diet (HFD). 3D multi- gradient-echo MRI at 15.2T was performed at baseline, 4, 8, 12, and 16 weeks after diet onset. A 3D fat-water separation algorithm and additional processing was used to generate FSF, local field offset, and T2* maps. We examined these parameters in perirenal AT ROIs from HFD and LFD mice. Results: The data suggest that FSF, local field offset, and T2* can differentiate time course behavior between inflamed and control AT (increasing FSF, decreasing local field offset, increasing followed by decreasing T2*). The biophysical mechanisms of these observed changes are not well understood and require further study. To the best of our knowledge, we report the first evidence that FWMRI can provide biomarkers sensitive to AT inflammation, and that FWMRI has the potential for longitudinal non-invasive assessment of AT inflammation in obesity.
Reductive evolution of architectural repertoires in proteomes and the birth of the tripartite world
Wang, Minglei; Yafremava, Liudmila S.; Caetano-Anollés, Derek; Mittenthal, Jay E.; Caetano-Anollés, Gustavo
2007-01-01
The repertoire of protein architectures in proteomes is evolutionarily conserved and capable of preserving an accurate record of genomic history. Here we use a census of protein architecture in 185 genomes that have been fully sequenced to generate genome-based phylogenies that describe the evolution of the protein world at fold (F) and fold superfamily (FSF) levels. The patterns of representation of F and FSF architectures over evolutionary history suggest three epochs in the evolution of the protein world: (1) architectural diversification, where members of an architecturally rich ancestral community diversified their protein repertoire; (2) superkingdom specification, where superkingdoms Archaea, Bacteria, and Eukarya were specified; and (3) organismal diversification, where F and FSF specific to relatively small sets of organisms appeared as the result of diversification of organismal lineages. Functional annotation of FSF along these architectural chronologies revealed patterns of discovery of biological function. Most importantly, the analysis identified an early and extensive differential loss of architectures occurring primarily in Archaea that segregates the archaeal lineage from the ancient community of organisms and establishes the first organismal divide. Reconstruction of phylogenomic trees of proteomes reflects the timeline of architectural diversification in the emerging lineages. Thus, Archaea undertook a minimalist strategy using only a small subset of the full architectural repertoire and then crystallized into a diversified superkingdom late in evolution. Our analysis also suggests a communal ancestor to all life that was molecularly complex and adopted genomic strategies currently present in Eukarya. PMID:17908824
Design, Modeling, Fabrication & Characterization of Industrial Si Solar Cells
NASA Astrophysics Data System (ADS)
Chowdhury, Ahrar Ahmed
Photovoltaic is a viable solution towards meeting the energy demand in an ecofriendly environment. To ensure the mass access in photovoltaic electricity, cost effective approach needs to be adapted. This thesis aims towards substrate independent fabrication process in order to achieve high efficiency cost effective industrial Silicon (Si) solar cells. Most cost-effective structures, such as, Al-BSF (Aluminum Back Surface Field), FSF (Front Surface Field) and bifacial cells are investigated in detail to exploit the efficiency potentials. First off, we introduced two-dimensional simulation model to design and modeling of most commonly used Si solar cells in today's PV arena. Best modelled results of high efficiency Al-BSF, FSF and bifacial cells are 20.50%, 22% and 21.68% respectively. Special attentions are given on the metallization design on all the structures in order to reduce the Ag cost. Furthermore, detail design and modeling were performed on FSF and bifacial cells. The FSF cells has potentials to gain 0.42%abs efficiency by combining the emitter design and front surface passivation. The prospects of bifacial cells can be revealed with the optimization of gridline widths and gridline numbers. Since, bifacial cells have metallization on both sides, a double fold cost saving is possible via innovative metallization design. Following modeling an effort is undertaken to reach the modelled result in fabrication the process. We proposed substrate independent fabrication process aiming towards establishing simultaneous processing sequences for both monofacial and bifacial cells. Subsequently, for the contact formation cost effective screen-printed technology is utilized throughout this thesis. The best Al-BSF cell attained efficiency ˜19.40%. Detail characterization was carried out to find a roadmap of achieving >20.50% efficiency Al-BSF cell. Since, n-type cell is free from Light Induced degradation (LID), recently there is a growing interest on FSF cell. Our best fabricated result of FSF cell achieved ˜18.40% efficiency. Characterizations on such cells provide that, cell performance can be further improved by utilizing high lifetime base wafer. We showed a step by step improvement on the device parameters to achieve ˜22% efficiency FSF cell. Finally, bifacial cells were fabricated with 13.32% front and 9.65% rear efficiency. The efficiency limitation is due to the quality of base wafer. Detail resistance breakdown was conducted on these cells to analyze parasitic resistance losses. It was found that base and gridline resistances dominated the FF loss. However, very low contact resistance of 20 mO-cm 2 at front side and 2 mO-cm2 at the rear side was observed by utilizing same Ag paste for front and rear contact formation. This might provide a pathway towards the search of an optimized Ag paste to attain high efficiency screen-printed bifacial cell. Detail investigations needs to be carried out to unveil the property of this Ag paste. In future work, more focus will be given on the metallization design to incorporate further reduction in Ag cost. Al2O3 passivation layer will be incorporated as a means to attain ˜23% screen-printed bifacial cell.
Steinhausen, Eva; Lefering, Rolf; Tjardes, Thorsten; Neugebauer, Edmund A M; Bouillon, Bertil; Rixen, Dieter
2014-05-01
Today, there is a trend toward damage-control orthopedics (DCO) in the management of multiple trauma patients with long bone fractures. However, there is no widely accepted concept. A risk-adapted approach seems to result in low acute morbidity and mortality. Multiple trauma patients with bilateral femoral shaft fractures (FSFs) are considered to be more severely injured. The objective of this study was to validate the risk-adapted approach in the management of multiple trauma patients with bilateral FSF. Data analysis is based on the trauma registry of the German Trauma Society (1993-2008, n = 42,248). Multiple trauma patients with bilateral FSF were analyzed in subgroups according to the type of primary operative strategy. Outcome parameters were mortality and major complications as (multiple) organ failure and sepsis. A total of 379 patients with bilateral FSF were divided into four groups as follows: (1) no operation (8.4%), (2) bilateral temporary external fixation (DCO) (50.9%), bilateral primary definitive osteosynthesis (early total care [ETC]) (25.1%), and primary definitive osteosynthesis of one FSF and DCO contralaterally (mixed) (15.6%). Compared with the ETC group, the DCO group was more severely injured. The incidence of (multiple) organ failure and mortality rates were higher in the DCO group but without significance. Adjusted for injury severity, there was no significant difference of mortality rates between DCO and ETC. Injury severity and mortality rates were significantly increased in the no-operation group. The mixed group was similar to the ETC group regarding injury severity and outcome. In Germany, both DCO and ETC are practiced in multiple trauma patients with bilateral FSF so far. The unstable or potentially unstable patient is reasonably treated with DCO. The clearly stable patient is reasonably treated with nailing. When in doubt, the patient is probably not totally stable, and the safest precaution may be to use DCO as a risk-adapted approach. Therapeutic study, level IV. Epidemiologic study, level III.
NASA Astrophysics Data System (ADS)
Lee, C.-C.; Chen, W. S.; Chu, F. D.
2013-06-01
For solar minimum, the spread F, GPS phase fluctuations, and plasma bubbles near the crest of equatorial ionization anomaly (EIA) are simultaneously analyzed to investigate F region irregularities for the first time. The data were observed using the Chungli ionosonde, YMSM GPS receiver, and DMSP satellites during 1996. It is found that in the observed ionograms, the frequency spread F (FSF) usually comes after the range spread F (RSF) in a series of nighttime spread F events. This results in that the maximum occurrence of RSF appears before that of FSF in the nighttime variations in occurrence probabilities. Moreover, the seasonal variation for RSF is close to that for FSF. Both have a board maximum in the J-months and a secondary maximum in December. These indicate that RSF and FSF should be regarded as one type of spread F, which is the all spread F (ASF) in this study. Because the equatorial plasma bubbles occur infrequently during solar minimum, the F region irregularities forming ASF are not related to the equatorial spread F. On the other hand, the similarity in seasonal occurrence between ASF and medium-scale traveling ionospheric disturbances (MSTIDs) demonstrates that the F region irregularities near the EIA crest are mainly generated by the gradient drift instability driven by MSTIDs. The irregularities, generated by MSTIDs, mostly occur in the bottom side of the F region. Consequently, the events of significant GPS phase fluctuations and plasma bubble near the EIA crest are rare during 1996.
Hayes, Scott M.; Baena, Elsa; Truong, Trong-Kha; Cabeza, Roberto
2011-01-01
Although people do not normally try to remember associations between faces and physical contexts, these associations are established automatically, as indicated by the difficulty of recognizing familiar faces in different contexts (“butcher-on-the-bus” phenomenon). The present functional MRI (fMRI) study investigated the automatic binding of faces and scenes. In the Face-Face (F-F) condition, faces were presented alone during both encoding and retrieval, whereas in the Face/Scene-Face (FS-F) condition, they were presented overlaid on scenes during encoding but alone during retrieval (context change). Although participants were instructed to focus only on the faces during both encoding and retrieval, recognition performance was worse in the FS-F than the F-F condition (“context shift decrement”—CSD), confirming automatic face-scene binding during encoding. This binding was mediated by the hippocampus as indicated by greater subsequent memory effects (remembered > forgotten) in this region for the FS-F than the F-F condition. Scene memory was mediated by the right parahippocampal cortex, which was reactivated during successful retrieval when the faces were associated with a scene during encoding (FS-F condition). Analyses using the CSD as a regressor yielded a clear hemispheric asymmetry in medial temporal lobe activity during encoding: left hippocampal and parahippocampal activity was associated with a smaller CSD, indicating more flexible memory representations immune to context changes, whereas right hippocampal/rhinal activity was associated with a larger CSD, indicating less flexible representations sensitive to context change. Taken together, the results clarify the neural mechanisms of context effects on face recognition. PMID:19925208
NASA Astrophysics Data System (ADS)
Pietrella, M.; Pezzopane, M.; Fagundes, P. R.; de Jesus, R.; Supnithi, P.; Klinngam, S.; Ezquer, R. G.; Cabrera, M. A.
2017-11-01
A comparative study aimed to investigate the equatorial and low-latitude spread-F occurrences for moderate solar activity (MSA) and high solar activity (HSA), was carried out considering concurrent observations made in some ionospheric stations, which identify three separate longitudinal sectors: Chiang Mai (CGM; 18.8° N, 98.9° E, mag. Lat. 13.2° N) and Chumphon (CPN; 10.7° N, 99.4° E, mag. Lat. 3.2° N), Thailand; Palmas (PAL; 10.2° S, 311.8° E, mag. Lat. 0.9° S) and São José dos Campos (SJC; 23.2° S, 314.1° E, mag. Lat. 14.0° S), Brazil; Tucumán (TUC; 26.9° S, 294.6° E, mag. Lat. 16.8° S), Argentina. Spread-F phenomena recorded during the equinoctial months of September and October 2010, March and April 2011, for MSA, March and April 2014, September and October 2014, for HSA, were classified in two different modes: range spread-F (RSF) and frequency spread-F (FSF). The satellite trace (ST) occurrence was also investigated as possible precursor of spread-F events. When comparing the results of equatorial (CPN and PAL) and low-latitude (CGM, SJC, and TUC) stations, some common features independently of the solar activity emerge: (1) a prevalence of RSF signatures is observed in the time interval 20:00-03:00 LT, while FSF occurrences prevail in the time interval 03:00-06:00 LT; (2) STs are confirmed to be a possible precursor of RSF occurrences. For HSA, at equatorial latitudes, spread-F occurrences in the Thai sector (CPN) are higher than those observed in the Brazilian sector (PAL). When comparing the results of low-latitude stations of CGM, SJC, and TUC some unusual aspects characterizing the morphology of spread-F occurrences emerge: (1) contrary to the Thai and Argentine sectors, in the Brazilian sector (SJC), RSF and FSF appearances in September, for HSA, are observed with relatively long persistence times between about 03:00-06:00 LT and 01:00-03:00 LT respectively, while balanced RSF and FSF occurrences with short persistence times are observed for months for MSA; (2) a prevalence of FSF at CGM during the first half of September for MSA, never observed in the Brazilian and Argentine areas. During years of LSA and MSA common morphological aspects are found at CGM and SJC, that is a predominance of FSF, with the lowest persistence times characterizing SJC. This suggests that the low-latitude behaviour of spread-F occurrences, under different levels of solar activity, at least in the longitude sectors here analysed, can be to a some extent generalized.
Ghasimi, Dara S M; Zandvoort, Marcel H; Adriaanse, Michiel; van Lier, Jules B; de Kreuk, Merle
2016-07-01
Sewage fine sieved fraction (FSF) is a heterogeneous substrate consisting of mainly toilet paper fibers sequestered from municipal raw sewage by a fine screen. In earlier studies, a maximum biodegradation of 62% and 57% of the sewage FSF was found under thermophilic (55°C) and mesophilic (35°C) conditions, respectively. In order to research this limited biodegradability of sewage FSF, this study investigates the biodegradation of different types of cellulosic fibers-based hygiene papers including virgin fibers based toilet paper (VTP), recycled fiber based toilet paper (RTP), virgin pulp for paper production (VPPP) as a raw material, as well as microcrystalline cellulose (MCC) as a kind of fiberless reference material. The anaerobic biodegradation or digestibility tests were conducted under thermophilic and mesophilic conditions. Results of the experiments showed different biomethane potential (BMP) values for each tested cellulose fiber-based substrate, which might be associated with the physical characteristics of the fibers, type of pulping, presence of lignin encrusted fibers, and/or the presence of additive chemicals and refractory compounds. Higher hydrolysis rates (Kh), higher specific methane production rates (SMPR) and shorter required incubation times to achieve 90% of the BMP (t90%CH4), were achieved under thermophilic conditions for all examined substrates compared to the mesophilic ones. Furthermore, the biodegradability of all employed cellulose fiber-based substrates was in the same range, 38-45%, under both conditions and less than the observed FSF biodegradability, i.e. 57-62%. MCC achieved the highest BMP and biodegradability, 86-91%, among all cellulosic substrates. Copyright © 2016 Elsevier Ltd. All rights reserved.
Marcon, Magda; Ciritsis, Bernhard; Laux, Christoph; Nanz, Daniel; Fischer, Michael A; Andreisek, Gustav; Ulbrich, Erika J
2015-08-01
To quantitatively and qualitatively assess vastus medialis muscle atrophy in asymptomatic patients with anterior cruciate ligament reconstruction, using the nonoperated leg as control. Prospective Institutional Review Board approved study with written informed patient consent. Thirty-three asymptomatic patients (men, 21; women,12) with ACL-reconstruction underwent MR imaging of both legs (axial T1-weighted spin-echo and 3D spoiled dual gradient-echo sequences). Muscle volume and average fat-signal fraction (FSF) of the vastus medialis muscles were measured. Additionally, Goutallier classification was used to classify fatty muscle degeneration. Significant side differences were evaluated using the Wilcoxon test and, between volumes and FSF, using student t-tests with P-value < 0.05 and < 0.025, respectively. The muscle volume was significantly smaller in the operated (mean ± SD, 430.6 ± 119.6 cm(3) ; range, 197.3 to 641.7 cm(3) ) than in the nonoperated leg (479.5 ± 124.8 cm(3) ; 261.4 to 658.9 cm(3) ) (P < 0.001). Corresponding FSF was 6.3 ± 1.5% (3.9 to 9.2%) and 5.8 ± 0.9% (4.0 to 7.4%), respectively, with a nonsignificant (P > 0.025) difference. The relative muscle-volume and FSF differences were -10.1 ± 8.6% (7.1 to -30.1%) and 10.9 ± 29.4% (39.7 to 40.1%). The qualitative assessment revealed no significant differences (P > 0.1). A significant muscle volume loss of the vastus medialis muscle does exist in asymptomatic patients with ACL-reconstruction, but without fatty degeneration. © 2014 Wiley Periodicals, Inc.
Bernard, J K; Tao, S
2015-12-01
A completely randomized lactation trial was conducted to compare the production response of lactating Holstein cows to diets based on corn or forage sorghum silage harvested from 2 crops. Corn was planted in March and harvested in July (corn silage-summer; CSS) and a second corn crop was planted in July and harvested in November (corn silage-fall; CSF). A brachytic dwarf brown midrib forage sorghum was planted in April, harvested in July (forage sorghum-summer; FSS), fertilized, and harvested a second time in November (forage sorghum-fall; FSF). All forage was ensiled in plastic bags and stored until the production trial began. Silages contained (dry matter basis) 8.0, 8.5, 9.0, and 9.5% crude protein; 39.0, 38.3, 54.2, and 55.1% neutral detergent fiber; and 3.6, 2.8. 7.7, and 7.8% acid detergent lignin, for CSS, CSF, FSS, and FSF, respectively. Forty-eight mid-lactation Holstein cows (153.5±37.2d in milk, 35.7±6.2kg/d of milk, 3.2±0.6% fat, 611.8±67.0kg of body weight, and 2.96±0.09 body condition score) were assigned randomly to 1 of the 4diets differing in forage source. Cows were individually fed experimental diets once daily behind Calan doors for 5wk. Diets were formulated to contain 38.7% of the experimental forages and balanced to provide equal concentrations of protein, fiber, and energy. No differences were observed in dry matter intake and yields of milk and components, but milk fat percentage was lower for CSS and CSF compared with FSS and FSF, being 3.20, 2.91, 3.42, and 3.53%, respectively. Milk lactose percentage was lower for CSS compared with CSF but was not different from FSS or FSF. Concentrations of milk urea nitrogen were lower for CSS and CSF compared with FSS and FSF (10.6, 13.4, 14.9, and 15.3mg/dL, respectively). No differences were observed in body weight or body condition score change during the trial. Results of this trial suggest that silage produced from brachytic forage sorghum, as either the first or the ratoon crop, can support similar intake and performance as diets based on corn silage. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Aircraft ground damage and the use of predictive models to estimate costs
NASA Astrophysics Data System (ADS)
Kromphardt, Benjamin D.
Aircraft are frequently involved in ground damage incidents, and repair costs are often accepted as part of doing business. The Flight Safety Foundation (FSF) estimates ground damage to cost operators $5-10 billion annually. Incident reports, documents from manufacturers or regulatory agencies, and other resources were examined to better understand the problem of ground damage in aviation. Major contributing factors were explained, and two versions of a computer-based model were developed to project costs and show what is possible. One objective was to determine if the models could match the FSF's estimate. Another objective was to better understand cost savings that could be realized by efforts to further mitigate the occurrence of ground incidents. Model effectiveness was limited by access to official data, and assumptions were used if data was not available. However, the models were determined to sufficiently estimate the costs of ground incidents.
Hosseini, Mohsen; Asgary, Sedigheh
2012-01-01
BACKGROUND Coronary heart disease is the leading cause of mortality worldwide. A high-fat diet, rich in saturated fatty acids and low in polyunsaturated fatty acids, is said to be an important cause of atherosclerosis and cardiovascular diseases. METHODS In this experimental study, 40 male rabbits were randomly assigned to eight groups of five to receive normal diet, hypercholesterolemic diet, normal diet plus ghee, normal diet plus olive oil, normal diet plus hydrogenated oil, hypercholesterolemic diet plus ghee, hypercholesterolemic diet plus olive oil, and hypercholesterolemic diet plus hydrogenated oil. They received rabbit chow for a period of 12 weeks. At the start and end of the study, fasting blood samples were taken from all animals to measure biochemical factors including total cholesterol (TC), low-density lipoprotein (LDL), high-density lipoprotein (HDL), triglyceride (TG), fasting blood sugar (FBS), and C-reactive protein (CRP). Moreover, aorta, left and right coronary arteries were dissected at the end of the study to investigate fatty streak formation (FSF). Data was analyzed in SPSS at a significance level of 0.05. RESULTS In rabbits under normal diet, ghee significantly increased TC, LDL, and HDL compared to the beginning (P < 0.01) and also to the other two types of fat (P < 0.05). Moreover, normal diet plus olive oil significantly enhanced FSF in left coronary arteries and aorta compared to normal diet plus ghee. In groups receiving hypercholesterolemic diets, ghee significantly increased HDL and CRP (P < 0.05) and significantly decreased FBS (P < 0.01). The hypecholesterolemic diet plus olive oil significantly increased HDL (P < 0.01). Supplementation of hypecholesterolemic diet with ghee significantly increased HDL and FBS in comparison with hydrogenated oil. Significant increase of FBS was also detected with the use of ghee compared to olive oil. Ghee also significantly reduced FSF in left and right coronary arteries compared to olive oil. FSF in left coronary arteries was significantly lower in the hypecholesterolemic diet plus ghee group compared to the hypecholesterolemic diet plus hydrogenated oil group. CONCLUSION According to the achieved results, future clinical trial studies and investigation of other risk factors such as inflammatory factors are required. PMID:23358722
NASA Astrophysics Data System (ADS)
Guillet de Chatellus, H.; Lacot, E.; Glastre, W.; Jacquin, O.; Hugon, O.
2013-09-01
We provide a theoretical study of frequency-shifted feedback (FSF) lasers, i.e., lasers with an internal frequency shifter, seeded with a monochromatic wave. The resulting spectrum consists in a set of equidistant modes, labeled by n, whose phases vary quadratically with n. We prove the emergence of a temporal fractional Talbot effect, leading to generation of Fourier-transform-limited pulses at a repetition rate tunable by the parameters of the FSF cavity (cavity length and frequency shift per round trip), and limited by the spectral bandwidth of the laser. We characterize in detail the output field of this so-called “Talbot laser” and emphasize its specific intensity fluctuations. We evidence connections with some aspects of number theory by the appearance of Gauss sums and theta series in the expression of the laser field. Our predictions are in full agreement with the experimental results published in Guillet de Chatellus [Opt. ExpressOPEXFF1094-408710.1364/OE.21.015065 21, 15065 (2013)]. Practical applications and limitations are discussed.
40 CFR 89.119 - Emission tests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... consumption [G/Kw-hr]. FSF=fuel sulfur weight fraction. (3) Where a manufacturer certifies using test fuel... collected using test fuel with a sulfur content greater than 0.050 weight percent to determine compliance with the Tier 1 PM standards. (4) Where a manufacturer certifies using test fuel with a sulfur content...
40 CFR 89.119 - Emission tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... consumption [G/Kw-hr]. FSF=fuel sulfur weight fraction. (3) Where a manufacturer certifies using test fuel... collected using test fuel with a sulfur content greater than 0.050 weight percent to determine compliance with the Tier 1 PM standards. (4) Where a manufacturer certifies using test fuel with a sulfur content...
40 CFR 89.119 - Emission tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... consumption [G/Kw-hr]. FSF=fuel sulfur weight fraction. (3) Where a manufacturer certifies using test fuel... collected using test fuel with a sulfur content greater than 0.050 weight percent to determine compliance with the Tier 1 PM standards. (4) Where a manufacturer certifies using test fuel with a sulfur content...
FACILITY LAYOUT OF FUEL STORAGE BUILDING (CPP603) SHOWING STORAGE BASINS, ...
FACILITY LAYOUT OF FUEL STORAGE BUILDING (CPP-603) SHOWING STORAGE BASINS, FUEL ELEMENT CUTTING FACILITY, AND DRY GRAPHITE STORAGE FACILITY. INL DRAWING NUMBER 200-0603-00-030-056329. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
27 CFR 19.19 - Discontinuance of storage facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Discontinuance of storage... Provisions § 19.19 Discontinuance of storage facilities. If TTB determines that a proprietor's bonded storage... spirits stored in the facility to another storage facility. The transfer will take place at such time and...
27 CFR 19.19 - Discontinuance of storage facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Discontinuance of storage... Provisions § 19.19 Discontinuance of storage facilities. If TTB determines that a proprietor's bonded storage... spirits stored in the facility to another storage facility. The transfer will take place at such time and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-26
... proprietary software (e.g., Amazon's Kindle) to multipurpose devices running free software applications (e.g... Media Rights, Mozilla Corporation (``Mozilla''), and the Free Software Foundation (``FSF''), as well as... radical popularity over the past two years.'' EFF asserted that courts have long found copying and...
Fourier spatial frequency analysis for image classification: training the training set
NASA Astrophysics Data System (ADS)
Johnson, Timothy H.; Lhamo, Yigah; Shi, Lingyan; Alfano, Robert R.; Russell, Stewart
2016-04-01
The Directional Fourier Spatial Frequencies (DFSF) of a 2D image can identify similarity in spatial patterns within groups of related images. A Support Vector Machine (SVM) can then be used to classify images if the inter-image variance of the FSF in the training set is bounded. However, if variation in FSF increases with training set size, accuracy may decrease as the size of the training set increases. This calls for a method to identify a set of training images from among the originals that can form a vector basis for the entire class. Applying the Cauchy product method we extract the DFSF spectrum from radiographs of osteoporotic bone, and use it as a matched filter set to eliminate noise and image specific frequencies, and demonstrate that selection of a subset of superclassifiers from within a set of training images improves SVM accuracy. Central to this challenge is that the size of the search space can become computationally prohibitive for all but the smallest training sets. We are investigating methods to reduce the search space to identify an optimal subset of basis training images.
27 CFR 22.92 - Storage facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Storage facilities. 22.92... Storage facilities. (a) Storerooms or compartments shall be so constructed and secured as to prevent unauthorized access and will be equipped for locking. These storage facilities shall be of sufficient capacity...
27 CFR 22.92 - Storage facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Storage facilities. 22.92... Storage facilities. (a) Storerooms or compartments shall be so constructed and secured as to prevent unauthorized access and will be equipped for locking. These storage facilities shall be of sufficient capacity...
27 CFR 22.92 - Storage facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Storage facilities. 22.92... Storage facilities. (a) Storerooms or compartments shall be so constructed and secured as to prevent unauthorized access and will be equipped for locking. These storage facilities shall be of sufficient capacity...
27 CFR 22.92 - Storage facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Storage facilities. 22.92... Storage facilities. (a) Storerooms or compartments shall be so constructed and secured as to prevent unauthorized access and will be equipped for locking. These storage facilities shall be of sufficient capacity...
27 CFR 22.92 - Storage facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Storage facilities. 22.92... Storage facilities. (a) Storerooms or compartments shall be so constructed and secured as to prevent unauthorized access and will be equipped for locking. These storage facilities shall be of sufficient capacity...
46 CFR 108.237 - Fuel storage facilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...
46 CFR 108.237 - Fuel storage facilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...
46 CFR 108.237 - Fuel storage facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...
46 CFR 108.237 - Fuel storage facilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...
40 CFR 160.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...
40 CFR 160.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...
40 CFR 160.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...
40 CFR 160.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasser, K.
1994-06-01
In FY 1993, the Los Alamos National Laboratory Waste Management Group [CST-7 (formerly EM-7)] requested the Probabilistic Risk and Hazards Analysis Group [TSA-11 (formerly N-6)] to conduct a study of the hazards associated with several CST-7 facilities. Among these facilities are the Hazardous Waste Treatment Facility (HWTF), the HWTF Drum Storage Building (DSB), and the Mixed Waste Receiving and Storage Facility (MWRSF), which are proposed for construction beginning in 1996. These facilities are needed to upgrade the Laboratory`s storage capability for hazardous and mixed wastes and to provide treatment capabilities for wastes in cases where offsite treatment is not availablemore » or desirable. These facilities will assist Los Alamos in complying with federal and state requlations.« less
ERIC Educational Resources Information Center
Frank, Stephen
2012-01-01
Superintendent Andres A. Alonso arrived in Baltimore in 2007 with a vision for improving the city's struggling schools. His vision included empowering school leaders and creating accountability for student learning through a series of reforms that center around a new system for giving resources to schools, called Fair Student Funding (FSF). FSF…
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Compensation for grain storage facilities, flour... DOMESTIC QUARANTINE NOTICES Karnal Bunt § 301.89-16 Compensation for grain storage facilities, flour... the 1999-2000 and subsequent crop seasons. Owners of grain storage facilities, flour millers, and...
30 CFR 56.6800 - Storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...
30 CFR 56.6800 - Storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...
30 CFR 56.6800 - Storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...
30 CFR 56.6800 - Storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...
30 CFR 56.6800 - Storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...
30 CFR 56.4430 - Storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage facilities. 56.4430 Section 56.4430... Control Flammable and Combustible Liquids and Gases § 56.4430 Storage facilities. (a) Storage tanks for... changes. Vents for storage of Class I, II, or IIIA liquids shall be isolated or separated from ignition...
30 CFR 56.4430 - Storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage facilities. 56.4430 Section 56.4430... Control Flammable and Combustible Liquids and Gases § 56.4430 Storage facilities. (a) Storage tanks for... changes. Vents for storage of Class I, II, or IIIA liquids shall be isolated or separated from ignition...
30 CFR 56.4430 - Storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage facilities. 56.4430 Section 56.4430... Control Flammable and Combustible Liquids and Gases § 56.4430 Storage facilities. (a) Storage tanks for... changes. Vents for storage of Class I, II, or IIIA liquids shall be isolated or separated from ignition...
30 CFR 56.4430 - Storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage facilities. 56.4430 Section 56.4430... Control Flammable and Combustible Liquids and Gases § 56.4430 Storage facilities. (a) Storage tanks for... changes. Vents for storage of Class I, II, or IIIA liquids shall be isolated or separated from ignition...
STORAGE/SEDIMENTATION FACILITIES FOR CONTROL OF STORM AND COMBINED SEWER OVERFLOW: DESIGN MANUAL
This manual describes applications of storage facilities in wet-weather flow management and presents step-by-step procedures for analysis and design of storage-treatment facilities. Retention, detention, and sedimentation storage information is classified and described. Internati...
7 CFR 1436.4 - Application for loans.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., except loans for renewable biomass storage facilities and cold storage facilities for fruits and... the administrative county office. (2) For loans for renewable biomass storage facilities and cold...
7 CFR 1436.4 - Application for loans.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., except loans for renewable biomass storage facilities and cold storage facilities for fruits and... the administrative county office. (2) For loans for renewable biomass storage facilities and cold...
7 CFR 1436.4 - Application for loans.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., except loans for renewable biomass storage facilities and cold storage facilities for fruits and... the administrative county office. (2) For loans for renewable biomass storage facilities and cold...
7 CFR 1436.4 - Application for loans.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., except loans for renewable biomass storage facilities and cold storage facilities for fruits and... the administrative county office. (2) For loans for renewable biomass storage facilities and cold...
7 CFR 1436.4 - Application for loans.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., except loans for renewable biomass storage facilities and cold storage facilities for fruits and... the administrative county office. (2) For loans for renewable biomass storage facilities and cold...
Code of Federal Regulations, 2010 CFR
2010-07-01
... agency meet before it transfers records to a records storage facility? 1232.14 Section 1232.14 Parks... RECORDS TO RECORDS STORAGE FACILITIES § 1232.14 What requirements must an agency meet before it transfers records to a records storage facility? An agency must meet the following requirements before it transfers...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
The US Department of Energy (DOE) proposes to construct and maintain additional storage capacity at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee, for liquid low-level radioactive waste (LLLW). New capacity would be provided by a facility partitioned into six individual tank vaults containing one 100,000 gallon LLLW storage tank each. The storage tanks would be located within the existing Melton Valley Storage Tank (MVST) facility. This action would require the extension of a potable water line approximately one mile from the High Flux Isotope Reactor (HFIR) area to the proposed site to provide the necessary potable water for themore » facility including fire protection. Alternatives considered include no-action, cease generation, storage at other ORR storage facilities, source treatment, pretreatment, and storage at other DOE facilities.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... To Abandon Facilities and Services and To Acquire Facilities by Merger Steuben Gas Storage Company... Field Storage Facilities (Adrian Field) which Steuben operates pursuant to certificates of public... authorization to charge market based rates following its acquisition of the Adrian Field Storage Facility. The...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-03
... Assessment Reports for Dusky, Sandbar, and Blacknose Sharks in the U.S. Atlantic and Gulf of Mexico AGENCY... reports for dusky, sandbar, and blacknose sharks in the Atlantic and Gulf of Mexico. The reports summarize... sharks should be sent to Peter Cooper, Highly Migratory Species Management Division (F/SF1), National...
30 CFR 57.6130 - Explosive material storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Explosive material storage facilities. 57.6130 Section 57.6130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage-Surface Only § 57.6130 Explosive material storage facilities. (a) Detonators and explosives shall...
30 CFR 57.6130 - Explosive material storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Explosive material storage facilities. 57.6130 Section 57.6130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage-Surface Only § 57.6130 Explosive material storage facilities. (a) Detonators and explosives shall...
27 CFR 20.165 - Storage facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Storage facilities. 20.165... Users of Specially Denatured Spirits Premises and Equipment § 20.165 Storage facilities. (a) Storerooms... for locking. (b) Each stationary tank used for the storage of specially denatured spirits shall be...
27 CFR 20.165 - Storage facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Storage facilities. 20.165... Users of Specially Denatured Spirits Premises and Equipment § 20.165 Storage facilities. (a) Storerooms... for locking. (b) Each stationary tank used for the storage of specially denatured spirits shall be...
18 CFR 157.213 - Underground storage field facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...
27 CFR 20.165 - Storage facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Storage facilities. 20.165... Users of Specially Denatured Spirits Premises and Equipment § 20.165 Storage facilities. (a) Storerooms... for locking. (b) Each stationary tank used for the storage of specially denatured spirits shall be...
27 CFR 20.165 - Storage facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Storage facilities. 20.165... Users of Specially Denatured Spirits Premises and Equipment § 20.165 Storage facilities. (a) Storerooms... for locking. (b) Each stationary tank used for the storage of specially denatured spirits shall be...
18 CFR 157.213 - Underground storage field facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...
27 CFR 20.165 - Storage facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Storage facilities. 20.165... Users of Specially Denatured Spirits Premises and Equipment § 20.165 Storage facilities. (a) Storerooms... for locking. (b) Each stationary tank used for the storage of specially denatured spirits shall be...
46 CFR 108.237 - Fuel storage facilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...
30 CFR 56.6130 - Explosive material storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Explosive material storage facilities. 56.6130 Section 56.6130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage § 56.6130 Explosive material storage facilities. (a) Detonators and explosives shall be stored in...
30 CFR 57.4430 - Surface storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Surface storage facilities. 57.4430 Section 57... and Control Flammable and Combustible Liquids and Gases § 57.4430 Surface storage facilities. The requirements of this standard apply to surface areas only. (a) Storage tanks for flammable or combustible...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
27 CFR 19.79 - Discontinuance of storage facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Discontinuance of storage... Provisions Activities Not Subject to This Part § 19.79 Discontinuance of storage facilities. When the appropriate TTB officer finds that any facilities for the storage of spirits on bonded premises are unsafe or...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
30 CFR 57.4430 - Surface storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Surface storage facilities. 57.4430 Section 57... and Control Flammable and Combustible Liquids and Gases § 57.4430 Surface storage facilities. The requirements of this standard apply to surface areas only. (a) Storage tanks for flammable or combustible...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
30 CFR 56.6130 - Explosive material storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Explosive material storage facilities. 56.6130 Section 56.6130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage § 56.6130 Explosive material storage facilities. (a) Detonators and explosives shall be stored in...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
40 CFR 160.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Specimen and data storage facilities. 160.51 Section 160.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space...
Code of Federal Regulations, 2013 CFR
2013-07-01
... monitoring requirements for my storage vessel or centrifugal compressor affected facility? 60.5417 Section 60... requirements for my storage vessel or centrifugal compressor affected facility? You must meet the applicable... standards for your storage vessel or centrifugal compressor affected facility. (a) You must install and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... monitoring requirements for my storage vessel or centrifugal compressor affected facility? 60.5417 Section 60... requirements for my storage vessel or centrifugal compressor affected facility? You must meet the applicable... standards for your storage vessel or centrifugal compressor affected facility. (a) For each control device...
78 FR 15712 - Arlington Storage Company, LLC; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-12
... Storage Company, LLC; Notice of Application Take notice that on February 26, 2013, Arlington Storage... Commission's regulations, requesting authorization to expand its Seneca Lake natural gas storage facility... ``Gallery 2''), previously used for propane storage, and related facilities to natural gas storage. The...
Mohanraj, Rani; Kumar, Shuba; Manikandan, Sarojini; Kannaiyan, Veerapandian; Vijayakumar, Lakshmi
2014-08-01
Widespread use of pesticides among farmers in rural India, provides an easy means for suicide. A public health initiative involving storage of pesticides in a central storage facility could be a possible strategy for reducing mortality and morbidity related to pesticide poisoning. This qualitative study explored community perceptions towards a central pesticide storage facility in villages in rural South India. Sixteen focus group discussions held with consenting adults from intervention and control villages were followed by eight more a year after initiation of the storage facility. Analysis revealed four themes, namely, reasons for committing suicide and methods used, exposure to pesticides and first-aid practices, storage and disposal of pesticides, and perceptions towards the storage facility. The facility was appreciated as a means of preventing suicides and for providing a safe haven for pesticide storage. The participatory process that guided its design, construction and location ensured its acceptability. Use of qualitative methods helped provide deep insights into the phenomenon of pesticide suicide and aided the understanding of community perceptions towards the storage facility. The study suggests that communal storage of pesticides could be an important step towards reducing pesticide suicides in rural areas.
Code of Federal Regulations, 2012 CFR
2012-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2011 CFR
2011-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2010 CFR
2010-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2013 CFR
2013-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2014 CFR
2014-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Berry, David B; Padwal, Jennifer; Johnson, Seth; Parra, Callan L; Ward, Samuel R; Shahidi, Bahar
2018-05-07
Magnetic Resonance Imaging (MRI) is commonly used to assess the health of the lumbar spine and supporting structures. Studies have suggested that fatty infiltration of the posterior lumbar muscles is important in predicting responses to treatment for low back pain. However, methodological differences exist in defining the region of interest (ROI) of a muscle, which limits the ability to compare data between studies. The purpose of this study was to determine reliability and systematic differences within and between two commonly utilized methodologies for ROI definitions of lumbar paraspinal muscle. T2-weighted MRIs of the mid-L4 vertebrae from 37 patients with low back pain who were scheduled for lumbar spine surgery were included from a hospital database. Fatty infiltration for these patients ranged from low to high, based on Kjaer criteria. Two methods were used to define ROI: 1) segmentation of the multifidus and erector spinae based on fascial planes including epimuscular fat, and 2) segmentation of the multifidus and erector spinae based on visible muscle boundaries, which did not include epimuscular fat. Total cross sectional area (tCSA), fat signal fraction (FSF), muscle cross sectional area, and fat cross sectional area were measured. Degree of agreement between raters for each parameter was assessed using intra-class correlation coefficients (ICC) and area fraction of overlapping voxels. Excellent inter-rater agreement (ICC > 0.75) was observed for all measures for both methods. There was no significant difference between area fraction overlap of ROIs between methods. Method 1 demonstrated a greater tCSA for both the erector spinae (14-15%, p < 0.001) and multifidus (4%, p < 0.016) but a greater FSF only for the erector spinae (11-13%, p < 0.001). The two methods of defining lumbar spine muscle ROIs demonstrated excellent inter-rater reliability, although significant differences exist as method 1 showed larger CSA and FSF values compared to method 2. The results of this study confirm the validity of using either method to measure lumbar paraspinal musculature, and that method should be selected based on the primary outcome variables of interest.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sending permanent microform records to a records storage facility? 1238.28 Section 1238.28 Parks, Forests... MANAGEMENT Storage, Use, and Disposition of Microform Records § 1238.28 What must agencies do when sending permanent microform records to a records storage facility? Agencies must: (a) Follow the procedures in part...
Code of Federal Regulations, 2014 CFR
2014-07-01
... sending permanent microform records to a records storage facility? 1238.28 Section 1238.28 Parks, Forests... MANAGEMENT Storage, Use, and Disposition of Microform Records § 1238.28 What must agencies do when sending permanent microform records to a records storage facility? Agencies must: (a) Follow the procedures in part...
36 CFR 1254.28 - What items are not allowed in research rooms?
Code of Federal Regulations, 2011 CFR
2011-07-01
... papers. (b) You may store personal items at no cost in lockers or other storage facilities in the NARA facility. These lockers or other storage facilities are available on a first-come-first-served basis. (c) You must remove your personal belongings each night from the lockers or other storage facilities we...
36 CFR 1254.28 - What items are not allowed in research rooms?
Code of Federal Regulations, 2014 CFR
2014-07-01
... papers. (b) You may store personal items at no cost in lockers or other storage facilities in the NARA facility. These lockers or other storage facilities are available on a first-come-first-served basis. (c) You must remove your personal belongings each night from the lockers or other storage facilities we...
36 CFR 1254.28 - What items are not allowed in research rooms?
Code of Federal Regulations, 2010 CFR
2010-07-01
... papers. (b) You may store personal items at no cost in lockers or other storage facilities in the NARA facility. These lockers or other storage facilities are available on a first-come-first-served basis. (c) You must remove your personal belongings each night from the lockers or other storage facilities we...
36 CFR 1254.28 - What items are not allowed in research rooms?
Code of Federal Regulations, 2012 CFR
2012-07-01
... papers. (b) You may store personal items at no cost in lockers or other storage facilities in the NARA facility. These lockers or other storage facilities are available on a first-come-first-served basis. (c) You must remove your personal belongings each night from the lockers or other storage facilities we...
Log transfer and storage facilities in Southeast Alaska: a review.
Tamra L. Faris; Kenneth D. Vaughan
1985-01-01
The volume of timber harvested in southeast Alaska between 1909 and 1983 was 14,689 million board feet; nearly all was transported on water to various destinations for processing. In 1971 there were 69 active log transfer and storage facilities and 38 raft collecting and storage facilities in southeast Alaska. In 1983 there were 90 log transfer sites, 49 log storage...
Code of Federal Regulations, 2013 CFR
2013-07-01
... sending permanent microform records to a records storage facility? § 1238.28 Section § 1238.28 Parks... RECORDS MANAGEMENT Storage, Use, and Disposition of Microform Records § 1238.28 What must agencies do when sending permanent microform records to a records storage facility? Agencies must: (a) Follow the...
Emery, Robert J
2012-11-01
Faced with the prospect of being unable to permanently dispose of low-level radioactive wastes (LLRW) generated from teaching, research, and patient care activities, component institutions of the University of Texas System worked collaboratively to create a dedicated interim storage facility to be used until a permanent disposal facility became available. Located in a remote section of West Texas, the University of Texas System Interim Storage Facility (UTSISF) was licensed and put into operation in 1993, and since then has provided safe and secure interim storage for up to 350 drums of dry solid LLRW at any given time. Interim storage capability provided needed relief to component institutions, whose on-site waste facilities could have possibly become overburdened. Experiences gained from the licensing and operation of the site are described, and as a new permanent LLRW disposal facility emerges in Texas, a potential new role for the storage facility as a surge capacity storage site in times of natural disasters and emergencies is also discussed.
Developing a concept for a national used fuel interim storage facility in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Donald Wayne
2013-07-01
In the United States (U.S.) the nuclear waste issue has plagued the nuclear industry for decades. Originally, spent fuel was to be reprocessed but with the threat of nuclear proliferation, spent fuel reprocessing has been eliminated, at least for now. In 1983, the Nuclear Waste Policy Act of 1982 [1] was established, authorizing development of one or more spent fuel and high-level nuclear waste geological repositories and a consolidated national storage facility, called a 'Monitored Retrievable Storage' facility, that could store the spent nuclear fuel until it could be placed into the geological repository. Plans were under way to buildmore » a geological repository, Yucca Mountain, but with the decision by President Obama to terminate the development of Yucca Mountain, a consolidated national storage facility that can store spent fuel for an interim period until a new repository is established has become very important. Since reactor sites have not been able to wait for the government to come up with a storage or disposal location, spent fuel remains in wet or dry storage at each nuclear plant. The purpose of this paper is to present a concept developed to address the DOE's goals stated above. This concept was developed over the past few months by collaboration between the DOE and industry experts that have experience in designing spent nuclear fuel facilities. The paper examines the current spent fuel storage conditions at shutdown reactor sites, operating reactor sites, and the type of storage systems (transportable versus non-transportable, welded or bolted). The concept lays out the basis for a pilot storage facility to house spent fuel from shutdown reactor sites and then how the pilot facility can be enlarged to a larger full scale consolidated interim storage facility. (authors)« less
Simulation of mass storage systems operating in a large data processing facility
NASA Technical Reports Server (NTRS)
Holmes, R.
1972-01-01
A mass storage simulation program was written to aid system designers in the design of a data processing facility. It acts as a tool for measuring the overall effect on the facility of on-line mass storage systems, and it provides the means of measuring and comparing the performance of competing mass storage systems. The performance of the simulation program is demonstrated.
40 CFR 792.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Specimen and data storage facilities..., for the storage and retrieval of all raw data and specimens from completed studies. ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.51 Specimen and data...
40 CFR 792.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Specimen and data storage facilities..., for the storage and retrieval of all raw data and specimens from completed studies. ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.51 Specimen and data...
40 CFR 792.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Specimen and data storage facilities..., for the storage and retrieval of all raw data and specimens from completed studies. ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.51 Specimen and data...
40 CFR 792.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Specimen and data storage facilities..., for the storage and retrieval of all raw data and specimens from completed studies. ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.51 Specimen and data...
He, Wanzhong; Kivork, Christine; Machinani, Suman; Morphew, Mary K.; Gail, Anna M.; Tesar, Devin B.; Tiangco, Noreen E.; McIntosh, J. Richard; Bjorkman, Pamela J.
2007-01-01
We have developed methods to locate individual ligands that can be used for electron microscopy studies of dynamic events during endocytosis and subsequent intracellular trafficking. The methods are based on enlargement of 1.4 nm Nanogold attached to an endocytosed ligand. Nanogold, a small label that does not induce misdirection of ligand-receptor complexes, is ideal for labeling ligands endocytosed by live cells, but is too small to be routinely located in cells by electron microscopy. Traditional pre-embedding enhancement protocols to enlarge Nanogold are not compatible with high pressure freezing/freeze substitution fixation (HPF/FSF), the most accurate method to preserve ultrastructure and dynamic events during trafficking. We have developed an improved enhancement procedure for chemically-fixed samples that reduced autonucleation, and a new pre-embedding gold-enlarging technique for HPF/FSF samples that preserved contrast and ultrastructure and can be used for high-resolution tomography. We evaluated our methods using labeled Fc as a ligand for the neonatal Fc receptor. Attachment of Nanogold to Fc did not interfere with receptor binding or uptake, and gold-labeled Fc could be specifically enlarged to allow identification in 2D projections and in tomograms. These methods should be broadly applicable to many endocytosis and transcytosis studies. PMID:17723309
18 CFR 157.213 - Underground storage field facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... storage reservoir and within the buffer area; (4) A detailed description of present storage operations and..., provided the storage facility's certificated physical parameters—including total inventory, reservoir pressure, reservoir and buffer boundaries, and certificated capacity remain unchanged—and provided...
21 CFR 58.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Specimen and data storage facilities. 58.51..., for the storage and retrieval of all raw data and specimens from completed studies. ... GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.51 Specimen and data...
21 CFR 58.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Specimen and data storage facilities. 58.51..., for the storage and retrieval of all raw data and specimens from completed studies. ... GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.51 Specimen and data...
21 CFR 58.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Specimen and data storage facilities. 58.51..., for the storage and retrieval of all raw data and specimens from completed studies. ... GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.51 Specimen and data...
21 CFR 58.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Specimen and data storage facilities. 58.51..., for the storage and retrieval of all raw data and specimens from completed studies. ... GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.51 Specimen and data...
21 CFR 58.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Specimen and data storage facilities. 58.51..., for the storage and retrieval of all raw data and specimens from completed studies. ... GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.51 Specimen and data...
Management self assessment plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Debban, B.L.
Duke Engineering and Services Hanford Inc., Spent Nuclear Fuel Project is responsible for the operation of fuel storage facilities. The SNF project mission includes the safe removal, processing and transportation of Spent Nuclear Fuel from 100 K Area fuel storage basins to a new Storage facility in the Hanford 200 East Area. Its mission is the modification of the 100 K area fuel storage facilities and the construction of two new facilities: the 100 K Area Cold Vacuum Drying Facility, and the 200 East Area Canister Storage Building. The management self assessment plan described in this document is scheduled tomore » begin in April of 1999 and be complete in May of 1999. The management self assessment plan describes line management preparations for declaring that line management is ready to commence operations.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Ownership of an underground storage tank or underground storage tank system or facility or property on which an underground storage tank or underground storage tank system is located. 280.220 Section 280.220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...
Thermal Storage Materials Laboratory | Energy Systems Integration Facility
| NREL Materials Laboratory Thermal Storage Materials Laboratory In the Energy Systems Integration Facility's Thermal Storage Materials Laboratory, researchers investigate materials that can be used as high-temperature heat transfer fluids or thermal energy storage media in concentrating solar
Gómez-Vallejo, V; Lekuona, A; Baz, Z; Szczupak, B; Cossío, U; Llop, J
2016-09-29
A simple, straightforward and efficient method for the synthesis of [ 18 F]CF 4 and [ 18 F]SF 6 based on an ion beam-induced isotopic exchange reaction is presented. Positron emission tomography ventilation studies in rodents using [ 18 F]CF 4 showed a uniform distribution of the radiofluorinated gas within the lungs and rapid elimination after discontinuation of the administration.
Storage for greater-than-Class C low-level radioactive waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beitel, G.A.
1991-12-31
EG and G Idaho, Inc., at the Idaho National Engineering Laboratory (INEL) is actively pursuing technical storage alternatives for greater-than-Class C low-level radioactive waste (GTCC LLW) until a suitable licensed disposal facility is operating. A recently completed study projects that between 2200 and 6000 m{sup 3} of GTCC LLW will be generated by the year 2035; the base case estimate is 3250 m{sup 3}. The current plan envisions a disposal facility available as early as the year 2010. A long-term dedicated storage facility could be available in 1997. In the meantime, it is anticipated that a limited number of sealedmore » sources that are no longer useful and have GTCC concentrations of radionuclides will require storage. Arrangements are being made to provide this interim storage at an existing DOE waste management facility. All interim stored waste will subsequently be moved to the dedicated storage facility once it is operating. Negotiations are under way to establish a host site for interim storage, which may be operational, at the earliest, by the second quarter of 1993. Two major activities toward developing a long-term dedicated storage facility are ongoing. (a) An engineering study, which explores costs for alternatives to provide environmentally safe storage and satisfy all regulations, is being prepared. Details of some of the findings of that study will be presented. (b) There is also an effort under way to seek the assistance of one or more private companies in providing dedicated storage. Alternatives and options will be discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, J.W.
1993-08-01
The purpose of phase one of this study are: To understand the waste management system and a monitored retrievable storage facility; and to determine whether the applicant has real interest in pursuing the feasibility assessment process. Contents of this report are: Generating electric power; facts about exposure to radiation; handling storage, and transportation techniques; description of a proposed monitored retrievable storage facility; and benefits to be received by host jurisdiction.
36 CFR § 1254.28 - What items are not allowed in research rooms?
Code of Federal Regulations, 2013 CFR
2013-07-01
... for papers. (b) You may store personal items at no cost in lockers or other storage facilities in the NARA facility. These lockers or other storage facilities are available on a first-come-first-served basis. (c) You must remove your personal belongings each night from the lockers or other storage...
Code of Federal Regulations, 2011 CFR
2011-07-01
... agency create before it transfers records to a records storage facility? 1232.16 Section 1232.16 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF RECORDS TO RECORDS STORAGE FACILITIES § 1232.16 What documentation must an agency create before it...
Code of Federal Regulations, 2014 CFR
2014-07-01
... agency create before it transfers records to a records storage facility? 1232.16 Section 1232.16 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF RECORDS TO RECORDS STORAGE FACILITIES § 1232.16 What documentation must an agency create before it...
Code of Federal Regulations, 2012 CFR
2012-07-01
... agency create before it transfers records to a records storage facility? 1232.16 Section 1232.16 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF RECORDS TO RECORDS STORAGE FACILITIES § 1232.16 What documentation must an agency create before it...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolff, Dietmar; Voelzke, Holger; Weber, Wolfgang
2007-07-01
The German-Russian project that is part of the G8 initiative on Global Partnership Against the Spread of Weapons and Materials of Mass Destruction focuses on the speedy construction of a land-based interim storage facility for nuclear submarine reactor compartments at Sayda Bay near Murmansk. This project includes the required infrastructure facilities for long-term storage of about 150 reactor compartments for a period of about 70 years. The interim storage facility is a precondition for effective activities of decommissioning and dismantlement of almost all nuclear-powered submarines of the Russian Northern Fleet. The project also includes the establishment of a computer-assisted wastemore » monitoring system. In addition, the project involves clearing Sayda Bay of other shipwrecks of the Russian navy. On the German side the project is carried out by the Energiewerke Nord GmbH (EWN) on behalf of the Federal Ministry of Economics and Labour (BMWi). On the Russian side the Kurchatov Institute holds the project management of the long-term interim storage facility in Sayda Bay, whilst the Nerpa Shipyard, which is about 25 km away from the storage facility, is dismantling the submarines and preparing the reactor compartments for long-term interim storage. The technical monitoring of the German part of this project, being implemented by BMWi, is the responsibility of the Federal Institute for Materials Research and Testing (BAM). This paper gives an overview of the German-Russian project and a brief description of solutions for nuclear submarine disposal in other countries. At Nerpa shipyard, being refurbished with logistic and technical support from Germany, the reactor compartments are sealed by welding, provided with biological shielding, subjected to surface treatment and conservation measures. Using floating docks, a tugboat tows the reactor compartments from Nerpa shipyard to the interim storage facility at Sayda Bay where they will be left on the on-shore concrete storage space to allow the radioactivity to decay. For transport of reactor compartments at the shipyard, at the dock and at the storage facility, hydraulic keel blocks, developed and supplied by German subcontractors, are used. In July 2006 the first stage of the reactor compartment storage facility was commissioned and the first seven reactor compartments have been delivered from Nerpa shipyard. Following transports of reactor compartments to the storage facility are expected in 2007. (authors)« less
Alaska SAR Facility mass storage, current system
NASA Technical Reports Server (NTRS)
Cuddy, David; Chu, Eugene; Bicknell, Tom
1993-01-01
This paper examines the mass storage systems that are currently in place at the Alaska SAR Facility (SAF). The architecture of the facility will be presented including specifications of the mass storage media that are currently used and the performances that we have realized from the various media. The distribution formats and media are also discussed. Because the facility is expected to service future sensors, the new requirements and possible solutions to these requirements are also discussed.
Space Station tethered refueling facility operations
NASA Technical Reports Server (NTRS)
Kiefel, E. R.; Rudolph, L. K.; Fester, D. A.
1986-01-01
The space-based orbital transfer vehicle will require a large cryogenic fuel storage facility at the Space Station. An alternative to fuel storage onboard the Space Station, is on a tethered orbital refueling facility (TORF) which is separated from the Space Station by a sufficient distance to induce a gravity gradient to settle the propellants. Facility operations are a major concern associated with a tethered LO2/LH2 storage depot. A study was carried out to analyze these operations so as to identify the preferred TORF deployment direction (up or down) and whether the TORF should be permanently or intermittently deployed. The analyses considered safety, contamination, rendezvous, servicing, transportation rate, communication, and viewing. An upwardly, intermittently deployed facility is the preferred configuration for a tethered cryogenic fuel storage.
Financial Assurance Requirements for Hazardous Waste Treatment, Storage and Disposal Facilities
The Resource Conservation and Recovery Act (RCRA) requires all treatment, storage and disposal facilities (TSDFs) to demonstrate that they will have the financial resources to properly close the facility
40 CFR 94.509 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... disk, or some other method of data storage, depending upon the manufacturer's record retention..., associated storage facility or port facility, and the date the engine was received at the testing facility...
40 CFR 94.509 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... disk, or some other method of data storage, depending upon the manufacturer's record retention..., associated storage facility or port facility, and the date the engine was received at the testing facility...
40 CFR 94.509 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... disk, or some other method of data storage, depending upon the manufacturer's record retention..., associated storage facility or port facility, and the date the engine was received at the testing facility...
40 CFR 94.509 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... disk, or some other method of data storage, depending upon the manufacturer's record retention..., associated storage facility or port facility, and the date the engine was received at the testing facility...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false What documentation must an agency create before it transfers records to a records storage facility? 1232.16 Section 1232.16 Parks... RECORDS TO RECORDS STORAGE FACILITIES § 1232.16 What documentation must an agency create before it...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gasoline storage tanks if my facility is a bulk gasoline terminal, pipeline breakout station, or pipeline... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... § 63.11087 What requirements must I meet for gasoline storage tanks if my facility is a bulk gasoline...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gasoline storage tanks if my facility is a bulk gasoline terminal, pipeline breakout station, or pipeline... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... § 63.11087 What requirements must I meet for gasoline storage tanks if my facility is a bulk gasoline...
Code of Federal Regulations, 2010 CFR
2010-07-01
... gasoline storage tanks if my facility is a bulk gasoline terminal, pipeline breakout station, or pipeline... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... § 63.11087 What requirements must I meet for gasoline storage tanks if my facility is a bulk gasoline...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gasoline storage tanks if my facility is a bulk gasoline terminal, pipeline breakout station, or pipeline... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... § 63.11087 What requirements must I meet for gasoline storage tanks if my facility is a bulk gasoline...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gasoline storage tanks if my facility is a bulk gasoline terminal, pipeline breakout station, or pipeline... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... § 63.11087 What requirements must I meet for gasoline storage tanks if my facility is a bulk gasoline...
Code of Federal Regulations, 2013 CFR
2013-07-01
... agency meet before it transfers records to a records storage facility? § 1232.14 Section § 1232.14 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF RECORDS TO RECORDS STORAGE FACILITIES § 1232.14 What requirements must an agency meet before it...
303-K Storage Facility closure plan. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-12-15
Recyclable scrap uranium with zircaloy-2 and copper silicon alloy, uranium-titanium alloy, beryllium/zircaloy-2 alloy, and zircaloy-2 chips and fines were secured in concrete billets (7.5-gallon containers) in the 303-K Storage Facility, located in the 300 Area. The beryllium/zircaloy-2 alloy and zircaloy-2 chips and fines are designated as mixed waste with the characteristic of ignitability. The concretion process reduced the ignitability of the fines and chips for safe storage and shipment. This process has been discontinued and the 303-K Storage Facility is now undergoing closure as defined in the Resource Conservation and Recovery Act (RCRA) of 1976 and the Washington Administrative Codemore » (WAC) Dangerous Waste Regulations, WAC 173-303-040. This closure plan presents a description of the 303-K Storage Facility, the history of materials and waste managed, and the procedures that will be followed to close the 303-K Storage Facility. The 303-K Storage Facility is located within the 300-FF-3 (source) and 300-FF-5 (groundwater) operable units, as designated in the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) (Ecology et al. 1992). Contamination in the operable units 300-FF-3 and 300-FF-5 is scheduled to be addressed through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 remedial action process. Therefore, all soil remedial action at the 304 Facility will be conducted as part of the CERCLA remedial action of operable units 300-FF-3 and 300-FF-5.« less
The proteomic complexity and rise of the primordial ancestor of diversified life
2011-01-01
Background The last universal common ancestor represents the primordial cellular organism from which diversified life was derived. This urancestor accumulated genetic information before the rise of organismal lineages and is considered to be either a simple 'progenote' organism with a rudimentary translational apparatus or a more complex 'cenancestor' with almost all essential biological processes. Recent comparative genomic studies support the latter model and propose that the urancestor was similar to modern organisms in terms of gene content. However, most of these studies were based on molecular sequences, which are fast evolving and of limited value for deep evolutionary explorations. Results Here we engage in a phylogenomic study of protein domain structure in the proteomes of 420 free-living fully sequenced organisms. Domains were defined at the highly conserved fold superfamily (FSF) level of structural classification and an iterative phylogenomic approach was used to reconstruct max_set and min_set FSF repertoires as upper and lower bounds of the urancestral proteome. While the functional make up of the urancestral sets was complex, they represent only 5-11% of the 1,420 FSFs of extant proteomes and their make up and reuse was at least 5 and 3 times smaller than proteomes of free-living organisms, repectively. Trees of proteomes reconstructed directly from FSFs or from molecular functions, which included the max_set and min_set as articial taxa, showed that urancestors were always placed at their base and rooted the tree of life in Archaea. Finally, a molecular clock of FSFs suggests the min_set reflects urancestral genetic make up more reliably and confirms diversified life emerged about 2.9 billion years ago during the start of planet oxygenation. Conclusions The minimum urancestral FSF set reveals the urancestor had advanced metabolic capabilities, was especially rich in nucleotide metabolism enzymes, had pathways for the biosynthesis of membrane sn1,2 glycerol ester and ether lipids, and had crucial elements of translation, including a primordial ribosome with protein synthesis capabilities. It lacked however fundamental functions, including transcription, processes for extracellular communication, and enzymes for deoxyribonucleotide synthesis. Proteomic history reveals the urancestor is closer to a simple progenote organism but harbors a rather complex set of modern molecular functions. PMID:21612591
30 CFR 57.4130 - Surface electric substations and liquid storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...
30 CFR 57.4130 - Surface electric substations and liquid storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...
30 CFR 57.4130 - Surface electric substations and liquid storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...
30 CFR 57.4130 - Surface electric substations and liquid storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...
75 FR 52937 - Turtle Bayou Gas Storage Company, LLC; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-30
...] Turtle Bayou Gas Storage Company, LLC; Notice of Application August 20, 2010. Take notice that on August 6, 2010, Turtle Bayou Gas Storage Company, LLC (Turtle Bayou), One Office Park Circle, Suite 300..., operate, and maintain a new salt dome natural gas storage facility in two caverns and related facilities...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-20
... operation of natural gas facilities in Sheridan County and Campbell County, Wyoming and modification of underground storage facilities at its Baker Storage Reservoir in Fallon County, Montana. The details of... firm storage deliverability from its Baker Storage Reservoir that it will use to make up for declining...
Lessons learned from the Siting Process of an Interim Storage Facility in Spain - 12024
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamolla, Meritxell Martell
2012-07-01
On 29 December 2009, the Spanish government launched a site selection process to host a centralised interim storage facility for spent fuel and high-level radioactive waste. It was an unprecedented call for voluntarism among Spanish municipalities to site a controversial facility. Two nuclear municipalities, amongst a total of thirteen municipalities from five different regions, presented their candidatures to host the facility in their territories. For two years the government did not make a decision. Only in November 30, 2011, the new government elected on 20 November 2011 officially selected a non-nuclear municipality, Villar de Canas, for hosting this facility. Thismore » paper focuses on analysing the factors facilitating and hindering the siting of controversial facilities, in particular the interim storage facility in Spain. It demonstrates that involving all stakeholders in the decision-making process should not be underestimated. In the case of Spain, all regional governments where there were candidate municipalities willing to host the centralised interim storage facility, publicly opposed to the siting of the facility. (author)« less
Security Force Assistance Logistics: The Key to Self-Reliance?
2011-05-19
internal defense – the umbrella term that SFA falls under – and directly linked to assisting the foreign security force (FSF) “with the procurement...ideology.6 To some extent or another logistics figures prominently under the umbrella of military advising, so there is understandably a certain degree...billion” under the Mutual Defense Assistance Program (MDAP), which “included more than 1,100 medium-gun M47 and M48 Patton tanks, 152 light-gun tanks
40 CFR 90.704 - Maintenance of records; submission of information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the..., associated storage facility or port facility, and the date the engine was received at the testing facility...
40 CFR 90.704 - Maintenance of records; submission of information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the..., associated storage facility or port facility, and the date the engine was received at the testing facility...
40 CFR 90.704 - Maintenance of records; submission of information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the..., associated storage facility or port facility, and the date the engine was received at the testing facility...
40 CFR 90.704 - Maintenance of records; submission of information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the..., associated storage facility or port facility, and the date the engine was received at the testing facility...
Age Differences in Face Processing: The Role of Perceptual Degradation and Holistic Processing.
Boutet, Isabelle; Meinhardt-Injac, Bozana
2018-01-24
We simultaneously investigated the role of three hypotheses regarding age-related differences in face processing: perceptual degradation, impaired holistic processing, and an interaction between the two. Young adults (YA) aged 20-33-year olds, middle-age adults (MA) aged 50-64-year olds, and older adults (OA) aged 65-82-year olds were tested on the context congruency paradigm, which allows measurement of face-specific holistic processing across the life span (Meinhardt-Injac, Persike & Meinhardt, 2014. Acta Psychologica, 151, 155-163). Perceptual degradation was examined by measuring performance with faces that were not filtered (FSF), with faces filtered to preserve low spatial frequencies (LSF), and with faces filtered to preserve high spatial frequencies (HSF). We found that reducing perceptual signal strength had a greater impact on MA and OA for HSF faces, but not LSF faces. Context congruency effects were significant and of comparable magnitude across ages for FSF, LSF, and HSF faces. By using watches as control objects, we show that these holistic effects reflect face-specific mechanisms in all age groups. Our results support the perceptual degradation hypothesis for faces containing only HSF and suggest that holistic processing is preserved in aging even under conditions of reduced signal strength. © The Author(s) 2018. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false What are the requirements for environmental controls for records storage facilities? 1234.14 Section 1234.14 Parks, Forests, and Public... storage space that is designed to preserve them for their full retention period. New records storage...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silviera, D.J.; Aaberg, R.L.; Cushing, C.E.
This environmental document includes a discussion of the purpose of a monitored retrievable storage facility, a description of two facility design concepts (sealed storage cask and field drywell), a description of three reference sites (arid, warm-wet, and cold-wet), and a discussion and comparison of the impacts associated with each of the six site/concept combinations. This analysis is based on a 15,000-MTU storage capacity and a throughput rate of up to 1800 MTU per year.
Comparison between two methods for forward calculation of ambient noise H/V spectral ratios
NASA Astrophysics Data System (ADS)
Garcia-Jerez, A.; Luzón, F.; Sanchez-Sesma, F. J.; Santoyo, M. A.; Albarello, D.; Lunedei, E.; Campillo, M.; Iturrarán-Viveros, U.
2011-12-01
The analysis of horizontal-to-vertical spectral ratios of ambient noise (NHVSR) is a valuable tool for seismic prospecting, particularly if both a dense spatial sampling and a low-cost procedure are required. Unfortunately, the computation method still lacks of a unanimously accepted theoretical basis and different approaches are currently being used for inversion of the ground structure from the measured H/V curves. Two major approaches for forward calculation of NHVSRs in a layered medium are compared in this work. The first one was developed by Arai and Tokimatsu (2004) and recently improved by Albarello and Lunedei (2011). It consists of a description of the wavefield as generated by Far Surface point Forces (FSF method). The second one is based on the work of Sánchez-Sesma et al. (2011) who consider ambient noise as a Diffuse WaveField (DWF method), taking advantage of the proportionality between its Fourier-transformed autocorrelation (power spectrum) and the imaginary part of the Green function when source and receiver are the same. In both methods, the NHVSR is written as (PH/PV)1/2, where PH and PV are the horizontal and vertical power spectra. In the FSF method these quantities are given by PV∝⊙m(1+1/2χm2α2)(ARm/kRm)2 PH∝⊙m{(1+1/2χm2α2)(ARm/kRm)2χm2+1/2α2(ALm/kLm)2} where kRm, χm and ARm are wavenumber, ellipticity and medium response of the m-th Rayleigh wave mode; kLm and ALm correspond to the m-th Love wave mode and α is the horizontal-to-vertical load ratio of the ambient noise sources. Some common factors are omitted in the expressions of PV and PH. On the other hand, the DWF method deals with the full wavefield including both surface and body waves. In order to make the comparison easier, and taking into account that surface waves are often the dominant components in wide spectral ranges, body wave contributions are neglected here. In this case, the PH and PV power spectra for the DWF method are reduced to the simple expressions: PV = 1/2 ⊙m ARm PH = 1/2 ⊙m (ARm χm2 + ALm) Thus, the main difference between these methods is the way in which the amount of energy injected in each surface wave mode is established: either following the energy equipartition principle (DWF method) or controlled by surface point loads with angle tan-1 α (FSF method). These methods have been numerically compared for a simple structure consisting of a plane layer overlaying a halfspace. S-wave velocity contrast was varied between 2 and 6, and Poisson ratios of the layer from 0.25 to 0.45 (using 0.25 for the halfspace). We set α=1 for the FSF method. Although both methods provide NHVSRs of similar shape and very close peak frequencies, peaks obtained from DWF are significantly smoother. Both ratios become constant as frequency increases, but their high frequency limits differ too. References Albarello, D. & E. Lunedei (2011). Near Surface Geophysics 9, In press. Arai, H. & K. Tokimatsu (2004). Bull. Seismol. Soc. Am. 94, 53-63. Sánchez-Sesma, F. J., M. Rodríguez, U. Iturrarán-Viveros, F. Luzón, M. Campillo, L. Margerin, A. García-Jerez, M. Suarez, M. A. Santoyo & A. Rodríguez-Castellanos (2011). Geophys. J. Int. 186, 221-225.
Thermal Storage Process and Components Laboratory | Energy Systems
Integration Facility | NREL Process and Components Laboratory Thermal Storage Process and Components Laboratory The Energy Systems Integration Facility's Thermal Systems Process and Components Laboratory supports research and development, testing, and evaluation of new thermal energy storage systems
NASA Technical Reports Server (NTRS)
Cottrell, Dinna L.
2011-01-01
The Stennis Space Center (SSC) Records Retention Facility is a centralized location for all SSC records, Records Management staff, and the SSC History Office. The building is a storm resistant facility and provides a secure environment for records housing. The Records Retention Facility was constructed in accordance with The National Archives and Records Administration (NARA) requirements for records storage, making it the first NARA compliant facility in the agency. Stennis Space Center's Records Retention Facility became operational in May 2010. The SSC Records Retention Facility ensures that the required federal records are preserved, managed and accessible to all interested personnel. The facility provides 20,000 cubic feet of records storage capacity for the purpose of managing the centers consolidated records within a central, protected environment. Records housed in the facility are in the form of paper, optical, film and magnetic media. Located within the SSC Records Retention Facility, the Records Management Office provides comprehensive records management services in the form of: a) Storage and life-cycle management of inactive records of all media types; b) Digitizing/scanning of records and documents; c) Non-textual/digital electronic records media storage, migration and transfer; d) Records Remediation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-21
... traditional turbine-generator facility. The pumped storage facility would consist of: (1) A new upper... storage facility would be 86,430 megawatt hours. The turbine-generator facility would consist of: (1) an... turbine-generator unit. The estimated annual generation of the turbine generator unit would be 17,286...
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, Lorraine M
From September 1949 until September 1966, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) leased property at the southeastern end of Montgomery City, Missouri, for the operation of a grain storage facility. During this time, commercial grain fumigants containing carbon tetrachloride were commonly used by the CCC/USDA and the private grain storage industry to preserve grain in their facilities.
Reducing drinking water supply chemical contamination: risks from underground storage tanks.
Enander, Richard T; Hanumara, R Choudary; Kobayashi, Hisanori; Gagnon, Ronald N; Park, Eugene; Vallot, Christopher; Genovesi, Richard
2012-12-01
Drinking water supplies are at risk of contamination from a variety of physical, chemical, and biological sources. Ranked among these threats are hazardous material releases from leaking or improperly managed underground storage tanks located at municipal, commercial, and industrial facilities. To reduce human health and environmental risks associated with the subsurface storage of hazardous materials, government agencies have taken a variety of legislative and regulatory actions--which date back more than 25 years and include the establishment of rigorous equipment/technology/operational requirements and facility-by-facility inspection and enforcement programs. Given a history of more than 470,000 underground storage tank releases nationwide, the U.S. Environmental Protection Agency continues to report that 7,300 new leaks were found in federal fiscal year 2008, while nearly 103,000 old leaks remain to be cleaned up. In this article, we report on an alternate evidence-based intervention approach for reducing potential releases from the storage of petroleum products (gasoline, diesel, kerosene, heating/fuel oil, and waste oil) in underground tanks at commercial facilities located in Rhode Island. The objective of this study was to evaluate whether a new regulatory model can be used as a cost-effective alternative to traditional facility-by-facility inspection and enforcement programs for underground storage tanks. We conclude that the alternative model, using an emphasis on technical assistance tools, can produce measurable improvements in compliance performance, is a cost-effective adjunct to traditional facility-by-facility inspection and enforcement programs, and has the potential to allow regulatory agencies to decrease their frequency of inspections among low risk facilities without sacrificing compliance performance or increasing public health risks. © 2012 Society for Risk Analysis.
SOUTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL ...
SOUTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTH. INL PHOTO NUMBER HD-54-15-2. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL ...
NORTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTH. INL PHOTO NUMBER HD-54-16-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
7 CFR 1436.9 - Loan amount and loan application approvals.
Code of Federal Regulations, 2011 CFR
2011-01-01
... data is not applicable to the storage need, a reasonable acreage projection may be made for newly... CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS FARM STORAGE FACILITY LOAN... by the FSA State committee. (b) The net cost for all storage facilities and handling equipment: (1...
7 CFR 1436.9 - Loan amount and loan application approvals.
Code of Federal Regulations, 2014 CFR
2014-01-01
... data is not applicable to the storage need, a reasonable acreage projection may be made for newly... CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS FARM STORAGE FACILITY LOAN... by the FSA State committee. (b) The net cost for all storage facilities and handling equipment: (1...
7 CFR 1436.9 - Loan amount and loan application approvals.
Code of Federal Regulations, 2010 CFR
2010-01-01
... data is not applicable to the storage need, a reasonable acreage projection may be made for newly... CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS FARM STORAGE FACILITY LOAN... by the FSA State committee. (b) The net cost for all storage facilities and handling equipment: (1...
7 CFR 1436.9 - Loan amount and loan application approvals.
Code of Federal Regulations, 2013 CFR
2013-01-01
... data is not applicable to the storage need, a reasonable acreage projection may be made for newly... CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS FARM STORAGE FACILITY LOAN... by the FSA State committee. (b) The net cost for all storage facilities and handling equipment: (1...
7 CFR 1436.9 - Loan amount and loan application approvals.
Code of Federal Regulations, 2012 CFR
2012-01-01
... data is not applicable to the storage need, a reasonable acreage projection may be made for newly... CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS FARM STORAGE FACILITY LOAN... by the FSA State committee. (b) The net cost for all storage facilities and handling equipment: (1...
40 CFR 63.8698 - What definitions apply to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... facility used to transfer oxidized asphalt from a storage tank into a tank truck, rail car, or barge... facility includes one or more asphalt flux blowing stills, asphalt flux storage tanks storing asphalt flux intended for processing in the blowing stills, oxidized asphalt storage tanks, and oxidized asphalt loading...
40 CFR 792.51 - Specimen and data storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Specimen and data storage facilities. 792.51 Section 792.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.51 Specimen and data...
9 CFR 149.7 - Recordkeeping at site.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... If the carcass storage facility or composting facility is located on the site, then the animal disposal plan must provide for a storage or composting facility that precludes rodent or wildlife contact... swine and other mammals by rendering, incineration, composting, burial, or other means, as allowed by...
EFFECTS OF MIXING AND AGING ON WATER QUALITY IN DISTRIBUTION SYSTEM STORAGE FACILITIES
Aging of water in distribution system storage facilities can lead to deterioration of the water quality due to loss of disinfectant residual and bacterial regrowth. Facilities should be operated to insure that the age of the water is not excessive taking into account the quality...
Concentrating Solar Power Projects - National Solar Thermal Power Facility
| Concentrating Solar Power | NREL National Solar Thermal Power Facility Status Date: February 13, 2014 Project Overview Project Name: National Solar Thermal Power Facility Country: India Location Capacity (Net): 1.0 MW Output Type: Steam Rankine Thermal Storage Storage Type: None
86. VIEW OF LIQUID NITROGEN STORAGE FACILITY LOCATED DIRECTLY WEST ...
86. VIEW OF LIQUID NITROGEN STORAGE FACILITY LOCATED DIRECTLY WEST OF THE SLC-3W FUEL APRON. NOTE HEAT EXCHANGER IN BACKGROUND. CAMERA TOWER LOCATED DIRECTLY IN FRONT OF LIQUID NITROGEN STORAGE TANK. NITROGEN AND HELIUM GAS STORAGE TANKS AT SOUTH END OF FUEL APRON IN LOWER RIGHT CORNER. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Safeguards-by-Design: Guidance for Independent Spent Fuel Dry Storage Installations (ISFSI)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trond Bjornard; Philip C. Durst
2012-05-01
This document summarizes the requirements and best practices for implementing international nuclear safeguards at independent spent fuel storage installations (ISFSIs), also known as Away-from- Reactor (AFR) storage facilities. These installations may provide wet or dry storage of spent fuel, although the safeguards guidance herein focuses on dry storage facilities. In principle, the safeguards guidance applies to both wet and dry storage. The reason for focusing on dry independent spent fuel storage installations is that this is one of the fastest growing nuclear installations worldwide. Independent spent fuel storage installations are typically outside of the safeguards nuclear material balance area (MBA)more » of the reactor. They may be located on the reactor site, but are generally considered by the International Atomic Energy Agency (IAEA) and the State Regulator/SSAC to be a separate facility. The need for this guidance is becoming increasingly urgent as more and more nuclear power plants move their spent fuel from resident spent fuel ponds to independent spent fuel storage installations. The safeguards requirements and best practices described herein are also relevant to the design and construction of regional independent spent fuel storage installations that nuclear power plant operators are starting to consider in the absence of a national long-term geological spent fuel repository. The following document has been prepared in support of two of the three foundational pillars for implementing Safeguards-by-Design (SBD). These are: i) defining the relevant safeguards requirements, and ii) defining the best practices for meeting the requirements. This document was prepared with the design of the latest independent dry spent fuel storage installations in mind and was prepared specifically as an aid for designers of commercial nuclear facilities to help them understand the relevant international requirements that follow from a country’s safeguards agreement with the IAEA. If these requirements are understood at the earliest stages of facility design, it will help eliminate the costly retrofit of facilities that has occurred in the past to accommodate nuclear safeguards, and will help the IAEA implement nuclear safeguards worldwide, especially in countries building their first nuclear facilities. It is also hoped that this guidance document will promote discussion between the IAEA, State Regulator/SSAC, Project Design Team, and Facility Owner/Operator at an early stage to ensure that new ISFSIs will be effectively and efficiently safeguarded. This is intended to be a living document, since the international nuclear safeguards requirements may be subject to revision over time. More importantly, the practices by which the requirements are met are continuously modernized by the IAEA and facility operators for greater efficiency and cost effectiveness. As these improvements are made, it is recommended that the subject guidance document be updated and revised accordingly.« less
Shuttle orbiter storage locker system: A study
NASA Technical Reports Server (NTRS)
Butler, D. R.; Schowalter, D. T.; Weil, D. C.
1973-01-01
Study has been made to assure maximum utility of storage space and crew member facilities in planned space shuttle orbiter. Techniques discussed in this study should be of interest to designers of storage facilities in which space is at premium and vibration is severe. Manufacturers of boats, campers, house trailers, and aircraft could benefit from it.
40 CFR 60.5395 - What standards apply to storage vessel affected facilities?
Code of Federal Regulations, 2014 CFR
2014-07-01
... undergoes fracturing or refracturing, you must comply with paragraph (d)(1) of this section as soon as liquids from the well following fracturing or refracturing are routed to the storage vessel affected... associated with fracturing or refracturing of a well feeding the storage vessel affected facility, you must...
Safety analysis report for the Waste Storage Facility. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bengston, S.J.
1994-05-01
This safety analysis report outlines the safety concerns associated with the Waste Storage Facility located in the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. The three main objectives of the report are: define and document a safety basis for the Waste Storage Facility activities; demonstrate how the activities will be carried out to adequately protect the workers, public, and environment; and provide a basis for review and acceptance of the identified risk that the managers, operators, and owners will assume.
2005-09-01
G Ot-T GOO) D. BRENT WILSON, P.E. Base Civil Engineer Kirtland Air Force Base Kirtland AFB Fuel Storage and Ofjloading Facilities Construction...September 2005 A-1 3 77 MSG/CEVQ DEPARTMENT OF THE AIR FORCE 3 77th Civil Engineer Division (AFMC) 2050 Wyoming Blvd SE, Suite 120 Kirtland AFB NM...FINAL FINDING OF NO SIGNIFICANT IMPACT FOR THE FOR CONSTRUCTION AND REP AIR OF FUEL STORAGE AND OFFLOADING FACILITIES AT KIRTLAND AIR FORCE
Shen, Jiajian; Liu, Wei; Stoker, Joshua; Ding, Xiaoning; Anand, Aman; Hu, Yanle; Herman, Michael G; Bues, Martin
2016-12-01
To find an efficient method to configure the proton fluence for a commercial proton pencil beam scanning (PBS) treatment planning system (TPS). An in-water dose kernel was developed to mimic the dose kernel of the pencil beam convolution superposition algorithm, which is part of the commercial proton beam therapy planning software, eclipse™ (Varian Medical Systems, Palo Alto, CA). The field size factor (FSF) was calculated based on the spot profile reconstructed by the in-house dose kernel. The workflow of using FSFs to find the desirable proton fluence is presented. The in-house derived spot profile and FSF were validated by a direct comparison with those calculated by the eclipse TPS. The validation included 420 comparisons of the FSFs from 14 proton energies, various field sizes from 2 to 20 cm and various depths from 20% to 80% of proton range. The relative in-water lateral profiles between the in-house calculation and the eclipse TPS agree very well even at the level of 10 -4 . The FSFs between the in-house calculation and the eclipse TPS also agree well. The maximum deviation is within 0.5%, and the standard deviation is less than 0.1%. The authors' method significantly reduced the time to find the desirable proton fluences of the clinical energies. The method is extensively validated and can be applied to any proton centers using PBS and the eclipse TPS.
RMP Guidance for Propane Storage Facilities - Main Text
This document is intended as comprehensive Risk Management Program guidance for larger propane storage or distribution facilities who already comply with propane industry standards. Includes sample RMP, and release calculations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837-1867. The... authority to establish or relocate records storage facilities? 1234.30 Section 1234.30 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT FACILITY STANDARDS FOR...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837-1867. The... authority to establish or relocate records storage facilities? 1234.30 Section 1234.30 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT FACILITY STANDARDS FOR...
40 CFR 761.213 - Use of manifest-Commercial storage and disposal facility requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS PCB Waste Disposal Records and Reports § 761.213... or disposal facility receives PCB waste accompanied by a manifest, the owner, operator or his/her... discrepancy space. (2) If a commercial storage or disposal facility receives an off-site shipment of PCB waste...
40 CFR 761.213 - Use of manifest-Commercial storage and disposal facility requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS PCB Waste Disposal Records and Reports § 761.213... or disposal facility receives PCB waste accompanied by a manifest, the owner, operator or his/her... discrepancy space. (2) If a commercial storage or disposal facility receives an off-site shipment of PCB waste...
Choi, Y. J.; Lee, S. R.; Oh, J-W.
2014-01-01
This study was conducted to investigate the effects of brown seaweed (Undaria pinnatifida) by-product and seaweed fusiforme (Hizikia fusiformis) by-product supplementation on growth performance and blood profiles including serum immunoglobulin (Ig) in broilers. Fermentation of seaweeds was conducted by Bacillus subtilis and Aspergillus oryzae. In a 5-wk feeding trial, 750 one-d-old broiler chicks were divided into 5 groups, and were assigned to the control diet or experimental diets including control+0.5% brown seaweed (BS) by-product, control+0.5% seaweed fusiforme (SF) by-product, control+0.5% fermented brown seaweed (FBS) by-product, and control+0.5% fermented seaweed fusiforme (FSF) by-product. As a consequence, body weight gain (BWG) and gain:feed of seaweed by-product groups were clearly higher, when compared to those of control diet group from d 18 to 35 and the entire experimental period (p<0.05). In mortality rate, seaweed by-product groups were significantly lower when compared to control diet group during entire experimental period (p<0.05). However, Feed Intake of experimental diets group was not different from that of the control group during the entire experimental period. Whereas, Feed Intake of fermented seaweed by-product groups was lower than that of non-fermented seaweed groups (p<0.05). Total organ weights, lipids, and glutamic oxalacetic transaminase (GOT) of all treatment groups were not different from those of control group. However, glutamic pyruvate transaminase (GPT) of all treatment groups was higher than that of control group at d 17 (p<0.05). In case of serum Igs concentration, the concentration of IgA antibody in BS, SF, FSF treatment groups was significantly higher than in control group at d 35 (p<0.01). IgA concentration in FBS supplementation groups was negligibly decreased when compared to the control group. IgM concentration in the serums of all treatment groups was significantly higher than in control group (p<0.05) and in fermented seaweed by-product groups were much higher than in non-fermented seaweed groups (p<0.05). On the other hand, IgG concentrations in all treatment groups were lower than in control group (p<0.05). Taken together, our results suggest that by-product dietary supplementation of BS, SF, FBS, and FSF in poultry may provide positive effects of growth performance and immune response. PMID:25050025
NV Energy Electricity Storage Valuation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellison, James F.; Bhatnagar, Dhruv; Samaan, Nader A.
2013-06-30
This study examines how grid-level electricity storage may benet the operations of NV Energy in 2020, and assesses whether those benets justify the cost of the storage system. In order to determine how grid-level storage might impact NV Energy, an hourly production cost model of the Nevada Balancing Authority (\\BA") as projected for 2020 was built and used for the study. Storage facilities were found to add value primarily by providing reserve. Value provided by the provision of time-of-day shifting was found to be limited. If regulating reserve from storage is valued the same as that from slower ramp ratemore » resources, then it appears that a reciprocating engine generator could provide additional capacity at a lower cost than a pumped storage hydro plant or large storage capacity battery system. In addition, a 25-MW battery storage facility would need to cost $650/kW or less in order to produce a positive Net Present Value (NPV). However, if regulating reserve provided by storage is considered to be more useful to the grid than that from slower ramp rate resources, then a grid-level storage facility may have a positive NPV even at today's storage system capital costs. The value of having storage provide services beyond reserve and time-of-day shifting was not assessed in this study, and was therefore not included in storage cost-benefit calculations.« less
Modern tornado design of nuclear and other potentially hazardous facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevenson, J.D.; Zhao, Y.
Tornado wind loads and other tornado phenomena, including tornado missiles and differential pressure effects, have not usually been considered in the design of conventional industrial, commercial, or residential facilities in the United States; however, tornado resistance has often become a design requirement for certain hazardous facilities, such as large nuclear power plants and nuclear materials and waste storage facilities, as well as large liquefied natural gas storage facilities. This article provides a review of current procedures for the design of hazardous industrial facilities to resist tornado effects. 23 refs., 19 figs., 13 tabs.
Electrochemical Hydrogen Storage in Facile Synthesized Co@N-Doped Carbon Nanoparticle Composites.
Zhou, Lina; Qu, Xiaosheng; Zheng, Dong; Tang, Haolin; Liu, Dan; Qu, Deyang; Xie, ZhiZhong; Li, Junsheng; Qu, Deyu
2017-11-29
A Co@nitrogen-doped carbon nanoparticle composite was synthesized via a facile molecular self-assembling procedure. The material was used as the host for the electrochemical storage of hydrogen. The hydrogen storage capacity of the material was over 300 mAh g -1 at a rate of 100 mAg -1 . It also exhibited superior stability for storage of hydrogen, high rate capability, and good cyclic life. Hybridizing metallic cobalt nanoparticle with nitrogen-doped mesoporous carbon is found to be a good approach for the electrochemical storage of hydrogen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacRae, W.T.
The Donald C. Cook nuclear plant is located in Bridgman, Michigan. As such, no low-level radioactive waste from the facility has been sent to burial since November 1990. The only option is storage. The plant is well prepared for storage. A new facility was built, so the plant now has >2265 M3 (80 000 ft 3 ) of storage capacity. There are a number of issues that have had to be addressed during the period of storage. These items include storage capacity and waste generation rates, the waste form and the packages used, and the regulatory issues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turbak, S. C.; Reichle, D. R.; Shriner, C. R.
1981-01-01
This document presents a state-of-the-art review of literature concerning turbine-related fish mortality. The review discusses conventional and, to a lesser degree, pumped-storage (reversible) hydroelectric facilities. Much of the research on conventional facilities discussed in this report deals with studies performed in the Pacific Northwest and covers both prototype and model studies. Research conducted on Kaplan and Francis turbines during the 1950s and 1960s has been extensively reviewed and is discussed. Very little work on turbine-related fish mortality has been undertaken with newer turbine designs developed for more modern small-scale hydropower facilities; however, one study on a bulb unit (Kaplan runner)more » has recently been released. In discussing turbine-related fish mortality at pumped-storage facilities, much of the literature relates to the Ludington Pumped Storage Power Plant. As such, it is used as the principal facility in discussing research concerning pumped storage.« less
Calcine Waste Storage at the Idaho Nuclear Technology and Engineering Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staiger, Merle Daniel; M. C. Swenson
2005-01-01
This report documents an inventory of calcined waste produced at the Idaho Nuclear Technology and Engineering Center during the period from December 1963 to May 2000. The report was prepared based on calciner runs, operation of the calcined solids storage facilities, and miscellaneous operational information that establishes the range of chemical compositions of calcined waste stored at Idaho Nuclear Technology and Engineering Center. The report will be used to support obtaining permits for the calcined solids storage facilities, possible treatment of the calcined waste at the Idaho National Engineering and Environmental Laboratory, and to ship the waste to an off-sitemore » facility including a geologic repository. The information in this report was compiled from calciner operating data, waste solution analyses and volumes calcined, calciner operating schedules, calcine temperature monitoring records, and facility design of the calcined solids storage facilities. A compact disk copy of this report is provided to facilitate future data manipulations and analysis.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... temporary records, including microforms and audiovisual and electronic records, must be stored in records..., unscheduled, and/or sample/select records. All records storage facilities that store microfilm, audiovisual...
Appendix D - Sample Bulk Storage Facility Plan
This sample Spill Prevention, Control and Countermeasure (SPCC) Plan in Appendix D is intended to provide examples and illustrations of how a bulk storage facility could address a variety of scenarios in its SPCC Plan.
NASA Astrophysics Data System (ADS)
Liu, Ting; Qu, Yunhuan; Meng, De; Zhang, Qiaoer; Lu, Xinhua
2018-01-01
China’s spent fuel storage in the pressurized water reactors(PWR) is stored with wet storage way. With the rapid development of nuclear power industry, China’s NPPs(NPPs) will not be able to meet the problem of the production of spent fuel. Currently the world’s major nuclear power countries use dry storage as a way of spent fuel storage, so in recent years, China study on additional spent fuel dry storage system mainly. Part of the PWR NPP is ready to apply for additional spent fuel dry storage system. It also need to safety classificate to spent fuel dry storage facilities in PWR, but there is no standard for safety classification of spent fuel dry storage facilities in China. Because the storage facilities of the spent fuel dry storage are not part of the NPP, the classification standard of China’s NPPs is not applicable. This paper proposes the safety classification suggestion of the spent fuel dry storage for China’s PWR NPP, through to the study on China’s safety classification principles of PWR NPP in “Classification for the items of pressurized water reactor nuclear power plants (GB/T 17569-2013)”, and safety classification about spent fuel dry storage system in NUREG/CR - 6407 in the United States.
Method for utilizing decay heat from radioactive nuclear wastes
Busey, H.M.
1974-10-14
Management of radioactive heat-producing waste material while safely utilizing the heat thereof is accomplished by encapsulating the wastes after a cooling period, transporting the capsules to a facility including a plurality of vertically disposed storage tubes, lowering the capsules as they arrive at the facility into the storage tubes, cooling the storage tubes by circulating a gas thereover, employing the so heated gas to obtain an economically beneficial result, and continually adding waste capsules to the facility as they arrive thereat over a substantial period of time.
The target vacuum storage facility at iThemba LABS
NASA Astrophysics Data System (ADS)
Neveling, R.; Kheswa, N. Y.; Papka, P.
2018-05-01
A number of nuclear physics experiments at iThemba LABS require target foils that consist of specific isotopes of elements which are reactive in air. Not only is it important to prepare these targets in a suitable environment to prevent oxidation, but consideration should also be given to the long term storage and handling facilities of such targets. The target vacuum storage facility at iThemba LABS, as well as additional hardware necessary to transport and install the target foils in the experimental chamber, will be discussed.
Integrated waste management system costs in a MPC system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Supko, E.M.
1995-12-01
The impact on system costs of including a centralized interim storage facility as part of an integrated waste management system based on multi-purpose canister (MPC) technology was assessed in analyses by Energy Resources International, Inc. A system cost savings of $1 to $2 billion occurs if the Department of Energy begins spent fuel acceptance in 1998 at a centralized interim storage facility. That is, the savings associated with decreased utility spent fuel management costs will be greater than the cost of constructing and operating a centralized interim storage facility.
Hanford Spent Nuclear Fuel Project recommended path forward
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, J.C.
The Spent Nuclear Fuel Project (the Project), in conjunction with the U.S. Department of Energy-commissioned Independent Technical Assessment (ITA) team, has developed engineered alternatives for expedited removal of spent nuclear fuel, including sludge, from the K Basins at Hanford. These alternatives, along with a foreign processing alternative offered by British Nuclear Fuels Limited (BNFL), were extensively reviewed and evaluated. Based on these evaluations, a Westinghouse Hanford Company (WHC) Recommended Path Forward for K Basins spent nuclear fuel has been developed and is presented in Volume I of this document. The recommendation constitutes an aggressive series of projects to construct andmore » operate systems and facilities to safely retrieve, package, transport, process, and store K Basins fuel and sludge. The overall processing and storage scheme is based on the ITA team`s proposed passivation and vault storage process. A dual purpose staging and vault storage facility provides an innovative feature which allows accelerated removal of fuel and sludge from the basins and minimizes programmatic risks beyond any of the originally proposed alternatives. The projects fit within a regulatory and National Environmental Policy Act (NEPA) overlay which mandates a two-phased approach to construction and operation of the needed facilities. The two-phase strategy packages and moves K Basins fuel and sludge to a newly constructed Staging and Storage Facility by the year 2000 where it is staged for processing. When an adjoining facility is constructed, the fuel is cycled through a stabilization process and returned to the Staging and Storage Facility for dry interim (40-year) storage. The estimated total expenditure for this Recommended Path Forward, including necessary new construction, operations, and deactivation of Project facilities through 2012, is approximately $1,150 million (unescalated).« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false How does an agency request authority to establish or relocate records storage facilities? 1234.30 Section 1234.30 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT FACILITY STANDARDS FOR...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false How does an agency request authority to establish or relocate records storage facilities? 1234.30 Section 1234.30 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT FACILITY STANDARDS FOR...
Dust exposure in workers from grain storage facilities in Costa Rica.
Rodríguez-Zamora, María G; Medina-Escobar, Lourdes; Mora, Glend; Zock, Jan-Paul; van Wendel de Joode, Berna; Mora, Ana M
2017-08-01
About 12 million workers are involved in the production of basic grains in Central America. However, few studies in the region have examined the occupational factors associated with inhalable dust exposure. (i) To assess the exposure to inhalable dust in workers from rice, maize, and wheat storage facilities in Costa Rica; (ii) to examine the occupational factors associated with this exposure; and (iii) to measure concentrations of respirable and thoracic particles in different areas of the storage facilities. We measured inhalable (<100μm) dust concentrations in 176 personal samples collected from 136 workers of eight grain storage facilities in Costa Rica. We also measured respirable (<4μm) and thoracic (<10μm) dust particles in several areas of the storage facilities. Geometric mean (GM) and geometric standard deviation (GSD) inhalable dust concentrations were 2.0mg/m 3 and 7.8 (range=<0.2-275.4mg/m 3 ). Personal inhalable dust concentrations were associated with job category [GM for category/GM for administrative staff and other workers (95% CI)=4.4 (2.6, 7.2) for packing; 20.4 (12.3, 34.7) for dehulling; 109.6 (50.1, 234.4) for unloading in flat bed sheds; 24.0 (14.5, 39.8) for unloading in pits; and 31.6 (18.6, 52.5) for drying], and cleaning task [15.8 (95% CI: 10.0, 26.3) in workers who cleaned in addition to their regular tasks]. Higher area concentrations of thoracic dust particles were found in wheat (GM and GSD=4.3mg/m 3 and 4.5) and maize (3.0mg/m 3 and 3.9) storage facilities, and in grain drying (2.3mg/m 3 and 3.1) and unloading (1.5mg/m 3 and 4.8) areas. Operators of grain storage facilities showed elevated inhalable dust concentrations, mostly above international exposure limits. Better engineering and administrative controls are needed. Copyright © 2017 Elsevier GmbH. All rights reserved.
3718-F Alkali Metal Treatment and Storage Facility Closure Plan. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The Hanford Site, located northwest of the city of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials, as well as for activities associated with nuclear energy development. The 300 Area of the Hanford Site contains reactor fuel manufacturing facilities and several research and development laboratories. The 3718-F Alkali Metal Treatment and Storage Facility (3718-F Facility), located in the 300 Area, was used to store and treat alkali metal wastes. Therefore, it is subject to the regulatory requirements for the storage and treatment of dangerous wastes. Closure will be conducted pursuant tomore » the requirements of the Washington Administrative Code (WAC) 173-303-610 (Ecology 1989) and 40 CFR 270.1. Closure also will satisfy the thermal treatment facility closure requirements of 40 CFR 265.381. This closure plan presents a description of the 3718-F Facility, the history of wastes managed, and the approach that will be followed to close the facility. Only hazardous constituents derived from 3718-F Facility operations will be addressed.« less
40 CFR 91.504 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the... shipped from the assembly plant, associated storage facility or port facility, and the date the engine was...
40 CFR 91.504 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the... shipped from the assembly plant, associated storage facility or port facility, and the date the engine was...
40 CFR 91.504 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the... shipped from the assembly plant, associated storage facility or port facility, and the date the engine was...
40 CFR 91.504 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... paper) or reduced to microfilm, floppy disk, or some other method of data storage, depending upon the... shipped from the assembly plant, associated storage facility or port facility, and the date the engine was...
Low-level radwaste storage facility at Hope Creek and Salem Generating Stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oyen, L.C.; Lee, K.; Bravo, R.
Following the January 1, 1993, closure of the radwaste disposal facilities at Beatty, Nevada, and Richland, Washington (to waste generators outside the compact), only Barnwell, South Carolina, is open to waste generators in most states. Barnwell is scheduled to stay open to waste generators outside the Southeast Compact until June 30, 1994. Continued delays in opening regional radwaste disposal facilities have forced most nuclear utilities to consider on-site storage of low-level radwaste. Public Service Electric and Gas Company (PSE G) considered several different radwaste storage options before selecting the design based on the steel-frame and metal-siding building design described inmore » the Electric Power Research Institute's (EPRI's) TR-100298 Vol. 2, Project 3800 report. The storage facility will accommodate waste generated by Salem units 1 and 2 and Hope Creek unit 1 for a 5-yr period and will be located within their common protected area.« less
The INFN-CNAF Tier-1 GEMSS Mass Storage System and database facility activity
NASA Astrophysics Data System (ADS)
Ricci, Pier Paolo; Cavalli, Alessandro; Dell'Agnello, Luca; Favaro, Matteo; Gregori, Daniele; Prosperini, Andrea; Pezzi, Michele; Sapunenko, Vladimir; Zizzi, Giovanni; Vagnoni, Vincenzo
2015-05-01
The consolidation of Mass Storage services at the INFN-CNAF Tier1 Storage department that has occurred during the last 5 years, resulted in a reliable, high performance and moderately easy-to-manage facility that provides data access, archive, backup and database services to several different use cases. At present, the GEMSS Mass Storage System, developed and installed at CNAF and based upon an integration between the IBM GPFS parallel filesystem and the Tivoli Storage Manager (TSM) tape management software, is one of the largest hierarchical storage sites in Europe. It provides storage resources for about 12% of LHC data, as well as for data of other non-LHC experiments. Files are accessed using standard SRM Grid services provided by the Storage Resource Manager (StoRM), also developed at CNAF. Data access is also provided by XRootD and HTTP/WebDaV endpoints. Besides these services, an Oracle database facility is in production characterized by an effective level of parallelism, redundancy and availability. This facility is running databases for storing and accessing relational data objects and for providing database services to the currently active use cases. It takes advantage of several Oracle technologies, like Real Application Cluster (RAC), Automatic Storage Manager (ASM) and Enterprise Manager centralized management tools, together with other technologies for performance optimization, ease of management and downtime reduction. The aim of the present paper is to illustrate the state-of-the-art of the INFN-CNAF Tier1 Storage department infrastructures and software services, and to give a brief outlook to forthcoming projects. A description of the administrative, monitoring and problem-tracking tools that play a primary role in managing the whole storage framework is also given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, T.A., Fluor Daniel Hanford
1997-02-06
The Immobilized Low-Activity Waste Interim Storage subproject will provide storage capacity for immobilized low-activity waste product sold to the U.S. Department of Energy by the privatization contractor. This statement of work describes the work scope (encompassing definition of new installations and retrofit modifications to four existing grout vaults), to be performed by the Architect-Engineer, in preparation of a conceptual design for the Immobilized Low-Activity Waste Interim Storage Facility.
30 CFR 56.6101 - Areas around explosive material storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... surrounding storage facilities for explosive material shall be clear of rubbish, brush, dry grass, and trees for 25 feet in all directions, except that live trees 10 feet or taller need not be removed. (b) Other...
Ground Water Monitoring Requirements for Hazardous Waste Treatment, Storage and Disposal Facilities
The groundwater monitoring requirements for hazardous waste treatment, storage and disposal facilities (TSDFs) are just one aspect of the Resource Conservation and Recovery Act (RCRA) hazardous waste management strategy for protecting human health and the
30 CFR 56.6101 - Areas around explosive material storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... surrounding storage facilities for explosive material shall be clear of rubbish, brush, dry grass, and trees for 25 feet in all directions, except that live trees 10 feet or taller need not be removed. (b) Other...
30 CFR 56.6101 - Areas around explosive material storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... surrounding storage facilities for explosive material shall be clear of rubbish, brush, dry grass, and trees for 25 feet in all directions, except that live trees 10 feet or taller need not be removed. (b) Other...
30 CFR 56.6101 - Areas around explosive material storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... surrounding storage facilities for explosive material shall be clear of rubbish, brush, dry grass, and trees for 25 feet in all directions, except that live trees 10 feet or taller need not be removed. (b) Other...
30 CFR 56.6101 - Areas around explosive material storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... surrounding storage facilities for explosive material shall be clear of rubbish, brush, dry grass, and trees for 25 feet in all directions, except that live trees 10 feet or taller need not be removed. (b) Other...
This working paper examines the effect of increased inspection frequency occurring under the Energy Policy Act of 2005 on compliance with release detection and prevention requirements at underground storage tank facilities in Louisiana.
Zeng, Teng; Mitch, William A
2016-03-15
Distribution system storage facilities are a critical, yet often overlooked, component of the urban water infrastructure. This study showed elevated concentrations of N-nitrosodimethylamine (NDMA), total N-nitrosamines (TONO), regulated trihalomethanes (THMs) and haloacetic acids (HAAs), 1,1-dichloropropanone (1,1-DCP), trichloroacetaldehyde (TCAL), haloacetonitriles (HANs), and haloacetamides (HAMs) in waters with ongoing nitrification as compared to non-nitrifying waters in storage facilities within five different chloraminated drinking water distribution systems. The concentrations of NDMA, TONO, HANs, and HAMs in the nitrifying waters further increased upon application of simulated distribution system chloramination. The addition of a nitrifying biofilm sample collected from a nitrifying facility to its non-nitrifying influent water led to increases in N-nitrosamine and halogenated DBP formation, suggesting the release of precursors from nitrifying biofilms. Periodic treatment of two nitrifying facilities with breakpoint chlorination (BPC) temporarily suppressed nitrification and reduced precursor levels for N-nitrosamines, HANs, and HAMs, as reflected by lower concentrations of these DBPs measured after re-establishment of a chloramine residual within the facilities than prior to the BPC treatment. However, BPC promoted the formation of halogenated DBPs while a free chlorine residual was maintained. Strategies that minimize application of free chlorine while preventing nitrification are needed to control DBP precursor release in storage facilities.
NASA Astrophysics Data System (ADS)
Fortkamp, Jonathan C.
Current needs in the nuclear industry and movements in the political arena indicate that authorization may soon be given for development of a federal interim storage facility for spent nuclear fuel. The initial stages of the design work have already begun within the Department of Energy and are being reviewed by the Nuclear Regulatory Commission. This dissertation addresses the radiation environment around an interim spent nuclear fuel storage facility. Specifically the dissertation characterizes the radiation dose rates around the facility based on a design basis source term, evaluates the changes in dose due to varying cask spacing configurations, and uses these results to define some applicable health physics principles for the storage facility. Results indicate that dose rates from the facility are due primarily from photons from the spent fuel and Co-60 activation in the fuel assemblies. In the modeled cask system, skyshine was a significant contribution to dose rates at distances from the cask array, but this contribution can be reduced with an alternate cask venting system. With the application of appropriate health physics principles, occupation doses can be easily maintained far below regulatory limits and maintained ALARA.
Final Environmental Assessment: Base-Wide Building Demolition Arnold Air Force Base, Tennessee
2006-02-01
Building • Engine Test Facility ( ETF )-B Exhauster • ETF -A Airside • ETF -A Exhauster • ETF -A Reefer • CE Facility • Rocket Storage • Von Karman Gas...Executive Order ESA Endangered Species Act ETF Engine Test Facility FamCamp Family Camping Area P:\\ARNOLDAFB\\333402DO42COMPLIANCE\\DEMOLITION...Fabrication Shop • Natural Resources Building • Salt Storage Building • Administration Building • Engine Test Facility ( ETF )-B Exhauster • ETF -A
NASA Astrophysics Data System (ADS)
Kaji, K.; Zhang, J.; Horie, H.; Akimoto, H.; Tanaka, K.
2013-12-01
Since the massive earthquake hit eastern Japan in March, 2011, our team has participated in the recovery planning for Kesen Association, which is a group of cities in northeastern Japan. As one of our proposals for the recovery planning for the community, we are designing energy management system with renewable energy (RE) and storage batteries. Some public facilities in the area have been used as refugee shelters, but refugees had to put up with life without electricity for a while after the disaster. If RE generator and storage batteries are introduced into the facilities, it is possible to provide refugees with electricity. In this study, the sizes of photovoltaic (PV) appliances and storage batteries to be introduced into one public facility are optimized. The optimization is based on simulation, in which electric energy is managed by charge and discharge of storage battery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaji, K.; Zhang, J.; Horie, H.
2013-12-10
Since the massive earthquake hit eastern Japan in March, 2011, our team has participated in the recovery planning for Kesen Association, which is a group of cities in northeastern Japan. As one of our proposals for the recovery planning for the community, we are designing energy management system with renewable energy (RE) and storage batteries. Some public facilities in the area have been used as refugee shelters, but refugees had to put up with life without electricity for a while after the disaster. If RE generator and storage batteries are introduced into the facilities, it is possible to provide refugeesmore » with electricity. In this study, the sizes of photovoltaic (PV) appliances and storage batteries to be introduced into one public facility are optimized. The optimization is based on simulation, in which electric energy is managed by charge and discharge of storage battery.« less
2004-03-26
KENNEDY SPACE CENTER, FLA. -- An aerial photo of the hangar and storage facility near the KSC Shuttle Landing Facility. The hangar was used to collect and evaluate the pieces of Columbia debris before they were moved to permanent storage in the Vehicle Assembly Building.
ALTERNATE METHODS OF MANURE HANDLING
The objectives of this research project were to (a) construct an inexpensive storage facility for solid dairy cow manure, (b) evaluate its performance and the extent of pollutants in runoff from storage facilities, and (c) determine current manure handling practices in Vermont an...
This page contains documents relevant to the synthetic minor NSR permi for the Thunder Butte Petroleum Services, Inc., Crude Storage and Loading Facility, located on the Fort Berthold Indian Reservation in Ward County, ND.
Microbial Condition of Water Samples from Foreign Fuel Storage Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berry, C.J.; Fliermans, C.B.; Santo Domingo, J.
1997-10-30
In order to assess the microbial condition of foreign nuclear fuel storage facilities, fourteen different water samples were received from facilities outside the United States that have sent spent nuclear fuel to SRS for wet storage. Each water sample was analyzed for microbial content and activity as determined by total bacteria, viable aerobic bacteria, viable anaerobic bacteria, viable sulfate- reducing bacteria, viable acid-producing bacteria and enzyme diversity. The results for each water sample were then compared to other foreign samples and to data from the receiving basin for off- site fuel (RBOF) at SRS.
Decay heat power of spent nuclear fuel of power reactors with high burnup at long-term storage
NASA Astrophysics Data System (ADS)
Ternovykh, Mikhail; Tikhomirov, Georgy; Saldikov, Ivan; Gerasimov, Alexander
2017-09-01
Decay heat power of actinides and fission products from spent nuclear fuel of power VVER-1000 type reactors at long-term storage is calculated. Two modes of storage are considered: mode in which single portion of actinides or fission products is loaded in storage facility, and mode in which actinides or fission products from spent fuel of one VVER reactor are added every year in storage facility during 30 years and then accumulated nuclides are stored without addition new nuclides. Two values of fuel burnup 40 and 70 MW·d/kg are considered for the mode of storage of single fuel unloading. For the mode of accumulation of spent fuel with subsequent storage, one value of burnup of 70 MW·d/kg is considered. Very long time of storage 105 years accepted in calculations allows to simulate final geological disposal of radioactive wastes. Heat power of fission products decreases quickly after 50-100 years of storage. The power of actinides decreases very slow. In passing from 40 to 70 MW·d/kg, power of actinides increases due to accumulation of higher fraction of 244Cm. These data are important in the back end of fuel cycle when improved cooling system of the storage facility will be required along with stronger radiation protection during storage, transportation and processing.
Stefaniak, Katarzyna; Wróżyńska, Magdalena
2018-02-01
Protection of common natural goods is one of the greatest challenges man faces every day. Extracting and processing natural resources such as mineral deposits contributes to the transformation of the natural environment. The number of activities designed to keep balance are undertaken in accordance with the concept of integrated order. One of them is the use of comprehensive systems of tailings storage facility monitoring. Despite the monitoring, system failures still occur. The quantitative aspect of the failures illustrates both the scale of the problem and the quantitative aspect of the consequences of tailings storage facility failures. The paper presents vast possibilities provided by the global monitoring in the effective prevention of these failures. Particular attention is drawn to the potential of using multidirectional monitoring, including technical and environmental monitoring by the example of one of the world's biggest hydrotechnical constructions-Żelazny Most Tailings Storage Facility (TSF), Poland. Analysis of monitoring data allows to take preventive action against construction failures of facility dams, which can have devastating effects on human life and the natural environment.
Final Long-Term Management and Storage of Elemental Mercury Environmental Impact Statement Volume1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2011-01-01
Pursuant to the Mercury Export Ban Act of 2008 (P.L. 110-414), DOE was directed to designate a facility or facilities for the long-term management and storage of elemental mercury generated within the United States. Therefore, DOE has analyzed the storage of up to 10,000 metric tons (11,000 tons) of elemental mercury in a facility(ies) constructed and operated in accordance with the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act (74 FR 31723).DOE prepared this Final Mercury Storage EIS in accordance with the National Environmental Policy Act of 1969 (NEPA), as amended (42 U.S.C. 4321 etmore » seq.), the Council on Environmental Quality (CEQ) implementing regulations (40 CFR 1500–1508), and DOE’s NEPA implementing procedures (10 CFR 1021) to evaluate reasonable alternatives for a facility(ies) for the long-term management and storage of elemental mercury. This Final Mercury Storage EIS analyzes the potential environmental, human health, and socioeconomic impacts of elemental mercury storage at seven candidate locations:Grand Junction Disposal Site near Grand Junction, Colorado; Hanford Site near Richland, Washington; Hawthorne Army Depot near Hawthorne, Nevada; Idaho National Laboratory near Idaho Falls, Idaho;Kansas City Plant in Kansas City, Missouri; Savannah River Site near Aiken, South Carolina; and Waste Control Specialists, LLC, site near Andrews, Texas. As required by CEQ NEPA regulations, the No Action Alternative was also analyzed as a basis for comparison. DOE intends to decide (1) where to locate the elemental mercury storage facility(ies) and (2) whether to use existing buildings, new buildings, or a combination of existing and new buildings. DOE’s Preferred Alternative for the long-term management and storage of mercury is the Waste Control Specialists, LLC, site near Andrews, Texas.« less
Final Long-Term Management and Storage of Elemental Mercury Environmental Impact Statement Volume 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Pursuant to the Mercury Export Ban Act of 2008 (P.L. 110-414), DOE was directed to designate a facility or facilities for the long-term management and storage of elemental mercury generated within the United States. Therefore, DOE has analyzed the storage of up to 10,000 metric tons (11,000 tons) of elemental mercury in a facility(ies) constructed and operated in accordance with the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act (74 FR 31723). DOE prepared this Final Mercury Storage EIS in accordance with the National Environmental Policy Act of 1969 (NEPA), as amended (42 U.S.C. 4321more » et seq.), the Council on Environmental Quality (CEQ) implementing regulations (40 CFR 1500–1508), and DOE’s NEPA implementing procedures (10 CFR 1021) to evaluate reasonable alternatives for a facility(ies) for the long-term management and storage of elemental mercury. This Final Mercury Storage EIS analyzes the potential environmental, human health, and socioeconomic impacts of elemental mercury storage at seven candidate locations: Grand Junction Disposal Site near Grand Junction, Colorado; Hanford Site near Richland, Washington; Hawthorne Army Depot near Hawthorne, Nevada; Idaho National Laboratory near Idaho Falls, Idaho; Kansas City Plant in Kansas City, Missouri; Savannah River Site near Aiken, South Carolina; and Waste Control Specialists, LLC, site near Andrews, Texas. As required by CEQ NEPA regulations, the No Action Alternative was also analyzed as a basis for comparison. DOE intends to decide (1) where to locate the elemental mercury storage facility(ies) and (2) whether to use existing buildings, new buildings, or a combination of existing and new buildings. DOE’s Preferred Alternative for the long-term management and storage of mercury is the Waste Control Specialists, LLC, site near Andrews, Texas.« less
Dosimetric investigation of dual energy photon beams with assymmetric collimator jaws
NASA Astrophysics Data System (ADS)
Varatharaj, C.; Ravikumar, M.; Supe, Sanjay S.; Sathiyan, S.; Ganesh, K. M.; Arunkumar, T.
2008-01-01
Many modern linear accelerators are equipped with asymmetric collimators or jaws that can be moved independently. Asymmetric jaws have got many clinical applications in radiation therapy. In the present study, the dosimetric characteristics of asymmetric collimators from our linear accelerator with 6 and 18 MV X-rays were carried out. The field size factors (FSF) and half value layer (HVL) were measured in a water phantom using 0.6 cc Farmer chamber for symmetric and asymmetric fields for both 6 and 18 MV X-rays. Measurements of beam penumbra, percentage depth dose (PDD), cross beam profiles and calculated isodose curves were measured by RFA 300 for both asymmetric and symmetric fields. The FSF were found to agree with in 3% for symmetric and asymmetric fields. The HVL in water was found to be 15.8 cm and 14.4 cm for 6 MV photons and 26 cm and 22.9 cm for 18 MV photons at the central axis and at 20 cm off the central axis. At 30 cm depth the percentage depth dose for symmetric and asymmetric fields were found to differ as high as 6% for 6 MV and 4% for 18 MV fields. No observable difference in penumbra was noticed for symmetric and asymmetric fields of same dimensions. The constrictions of isodose curves at the edge nearer to central axis were noticed for asymmetrically placed fields. The observed differences could be due to the passage of primary beam through differential thickness of the flattening filter which alters the beam quality.
Cheng, Tao; Xia, Rong-Gang; Dong, Shi-Kui; Yan, Xiao-Yu; Luo, Cong-Feng
2017-12-18
Intramedullary nailing (IMN) is a popular method in the management of femoral shaft fractures (FSFs). However, whether the association of IMN with pulmonary fat emboli can compromise the pulmonary and nervous systems is debatable. The purpose of this study is to compare IMN with the locked dual plating (LDP) method by assessing the clinical outcomes of FSF patients with head or chest injury. A total of 126 FSF patients were included in this study between January 2010 and July 2016 and divided into LDP and IMN groups. Patient demographic characteristics, operative time, blood loss, Harris Hip Score, Lysholm Knee Score, radiological outcomes, and systemic complications were collected and compared between the two treatment groups. Patients were followed up for at least 12 months. The LDP group performed better than IMN in terms of operative time, estimated blood loss amount, and malunion rate. Differences in function scores, fracture union rate, overall pulmonary complication rate, and in-hospital mortality between the two groups were not significant. Average radiographic union time was significantly longer in the LDP group (36.3 weeks) than in the IMN group (32.5 weeks). One case of fixation failure occurred postoperatively in the LDP group, whereas one case of fracture nonunion took place in the IMN group. Our findings suggest that dual-plating fixation is a promising method for FSFs with multiple injuries. However, the retrospective nature of this study necessitates high-quality trials to be performed to assess the clinical efficiency of dual plating.
DOT National Transportation Integrated Search
2004-01-01
The objectives of this study were to assess the quantity and quality of salt-contaminated water generated from stormwater runoff at VDOT's salt storage facilities and to evaluate management/treatment alternatives to reduce costs and better protect th...
30 CFR 57.6160 - Main facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Storage... facilities will not prevent escape from the mine, or cause detonation of the contents of another storage...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Applicability. 113.2 Section 113.2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.2 Applicability. This subpart applies to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Purpose. 113.1 Section 113.1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.1 Purpose. This subpart establishes size...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Definitions. 113.3 Section 113.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.3 Definitions. As used in this subpart...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Purpose. 113.1 Section 113.1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.1 Purpose. This subpart establishes size...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Exclusions. 113.5 Section 113.5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.5 Exclusions. This subpart does not apply...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Definitions. 113.3 Section 113.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.3 Definitions. As used in this subpart...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Exclusions. 113.5 Section 113.5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.5 Exclusions. This subpart does not apply...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Applicability. 113.2 Section 113.2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.2 Applicability. This subpart applies to...
Hanford facility dangerous waste permit application, PUREX storage tunnels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haas, C. R.
1997-09-08
The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to Part B permit application documentation submitted for individual, `operating` treatment, storage, and/or disposal units, such as the PUREX Storage Tunnels (this document, DOE/RL-90-24).
Salt deposits in Arizona promise gas-storage opportunities
Rauzi, S.L.
2002-01-01
Massive salt formations and their proximity to pipeline systems and power plants make Arizona attractive for natural gas storage. Caverns dissolved in subsurface salt are used to store LPG at Ferrellgas Partners LP facility near Holbrook and the AmeriGas Partners LP facility near Glendale. Three other companies are investigating the feasibility of storing natural gas in Arizona salt: Copper Eagle Gas Storage LLC, Desert Crossing Gas Storage and Transportation System LLC, and Aquila Inc. The most extensive salt deposits are in the Colorado Plateau Province. Marine and nonmarine salt deposits are present in Arizona.
40 CFR 160.45 - Test system supply facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Test system supply facilities. 160.45 Section 160.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... be storage areas, as needed, for feed, nutrients, soils, bedding, supplies, and equipment. Storage...
Cryogenic Fluid Management Facility
NASA Technical Reports Server (NTRS)
Eberhardt, R. N.; Bailey, W. J.
1985-01-01
The Cryogenic Fluid Management Facility is a reusable test bed which is designed to be carried within the Shuttle cargo bay to investigate the systems and technologies associated with the efficient management of cryogens in space. Cryogenic fluid management consists of the systems and technologies for: (1) liquid storage and supply, including capillary acquisition/expulsion systems which provide single-phase liquid to the user system, (2) both passive and active thermal control systems, and (3) fluid transfer/resupply systems, including transfer lines and receiver tanks. The facility contains a storage and supply tank, a transfer line and a receiver tank, configured to provide low-g verification of fluid and thermal models of cryogenic storage and transfer processes. The facility will provide design data and criteria for future subcritical cryogenic storage and transfer system applications, such as Space Station life support, attitude control, power and fuel depot supply, resupply tankers, external tank (ET) propellant scavenging, and ground-based and space-based orbit transfer vehicles (OTV).
78 FR 77445 - Tres Palacios Gas Storage LLC; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-23
... Gas Storage LLC; Notice of Application Take notice that on December 6, 2013, Tres Palacios Gas Storage... working gas storage capacity in its salt cavern natural gas storage facility located in Matagorda, Colorado, and Wharton Counties, Texas. Tres Palacios states that the proposed abandonment of storage...
The used nuclear fuel problem - can reprocessing and consolidated storage be complementary?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, C.; Thomas, I.
2013-07-01
This paper describes our CISF (Consolidated Interim Storage Facilities) and Reprocessing Facility concepts and show how they can be combined with a geologic repository to provide a comprehensive system for dealing with spent fuels in the USA. The performance of the CISF was logistically analyzed under six operational scenarios. A 3-stage plan has been developed to establish the CISF. Stage 1: the construction at the CISF site of only a rail receipt interface and storage pad large enough for the number of casks that will be received. The construction of the CISF Canister Handling Facility, the Storage Cask Fabrication Facility,more » the Cask Maintenance Facility and supporting infrastructure are performed during stage 2. The construction and placement into operation of a water-filled pool repackaging facility is completed for Stage 3. By using this staged approach, the capital cost of the CISF is spread over a number of years. It also allows more time for a final decision on the geologic repository to be made. A recycling facility will be built, this facility will used the NUEX recycling process that is based on the aqueous-based PUREX solvent extraction process, using a solvent of tri-N-butyl phosphate in a kerosene diluent. It is capable of processing spent fuels at a rate of 5 MT per day, at burn-ups up to 50 GWD per ton of spent fuels and a minimum of 5 years out-of-reactor cooling.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loftin, B.; Abramczyk, G.; Koenig, R.
Radioactive materials are stored in a variety of locations throughout the DOE complex. At the Savannah River Site (SRS), materials are stored within dedicated facilities. Each of those facilities has a documented safety analysis (DSA) that describes accidents that the facility and the materials within it may encounter. Facilities at the SRS are planning on utilizing the certified Model 9977 Shipping Package as a long term storage package and one of these facilities required ballistics testing. Specifically, in order to meet the facility DSA, the radioactive materials (RAM) must be contained within the storage package after impact by a .223more » caliber round. In order to qualify the Model 9977 Shipping Package for storage in this location, the package had to be tested under these conditions. Over the past two years, the Model 9977 Shipping Package has been subjected to a series of ballistics tests. The purpose of the testing was to determine if the 9977 would be suitable for use as a storage package at a Savannah River Site facility. The facility requirements are that the package must not release any of its contents following the impact in its most vulnerable location by a .223 caliber round. A package, assembled to meet all of the design requirements for a certified 9977 shipping configuration and using simulated contents, was tested at the Savannah River Site in March of 2011. The testing was completed and the package was examined. The results of the testing and examination are presented in this paper.« less
Working and Net Available Shell Storage Capacity
2017-01-01
Working and Net Available Shell Storage Capacity is the U.S. Energy Information Administration’s (EIA) report containing storage capacity data for crude oil, petroleum products, and selected biofuels. The report includes tables detailing working and net available shell storage capacity by type of facility, product, and Petroleum Administration for Defense District (PAD District). Net available shell storage capacity is broken down further to show the percent for exclusive use by facility operators and the percent leased to others. Crude oil storage capacity data are also provided for Cushing, Oklahoma, an important crude oil market center. Data are released twice each year near the end of May (data for March 31) and near the end of November (data for September 30).
Public acceptance for centralized storage and repositories of low-level waste session (Panel)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lutz, H.R.
1995-12-31
Participants from various parts of the world will provide a summary of their particular country`s approach to low-level waste management and the cost of public acceptance for low-level waste management facilities. Participants will discuss the number, geographic location, and type of low-level waste repositories and centralized storage facilities located in their countries. Each will discuss the amount, distribution, and duration of funds to gain public acceptance of these facilities. Participants will provide an estimated $/meter for centralized storage facilities and repositories. The panel will include a brief discussion about the ethical aspects of public acceptance costs, approaches for negotiating acceptance,more » and lessons learned in each country. The audience is invited to participate in the discussion.« less
On-site low level radwaste storage facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knauss, C.H.; Gardner, D.A.
1993-12-31
This paper will explore several storage and processing technologies that are available for the safe storage of low-level waste, their advantages and their limitations such that potential users may be able to determine which technology may be most appropriate for their particular application. Also, a brief discussion will be included on available types of shipping and disposal containers and waste forms for use in those containers when ready for ultimate disposal. For the purposes of this paper, the waste streams considered will be restricted to nuclear power plant wastes. Wastes that will be discussed are powdered and bead resins formore » cooling and reactor water clean-up, filter cartridges, solidified waste oils, and Dry Active Wastes (DAW), which consist of contaminated clothing, tools, respirator filters, etc. On-site storage methods that will be analyzed include a storage facility constructed of individual temporary shielded waste containers on a hard surface; an on-site, self contained low level radwaste facility for resins and filters; and an on-site storage and volume reduction facility for resins and filters; and an on-site DAW. Simple, warehouse-type buildings and pre-engineered metal buildings will be discussed only to a limited degree since dose rate projections can be high due to their lack of adequate shielding for radiation protection. Waste processing alternatives that will be analyzed for resins include dewatering, solidifying in Portland cement, solidifying in bituminous material, and solidifying in a vinyl ester styrene matrix. The storage methods describes will be analyzed for their ability to shield the populace from the effects of direct transmission and skyshine radiation when storing the above mentioned materials, which have been properly processed for storage and have been placed in suitable storage containers.« less
40 CFR 60.470 - Applicability and designation of affected facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.470 Applicability and designation of... mineral handling and storage facility at asphalt roofing plants; and each asphalt storage tank and each blowing still at asphalt processing plants, petroleum refineries, and asphalt roofing plants. (b) Any...
40 CFR 60.470 - Applicability and designation of affected facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.470 Applicability and designation of... mineral handling and storage facility at asphalt roofing plants; and each asphalt storage tank and each blowing still at asphalt processing plants, petroleum refineries, and asphalt roofing plants. (b) Any...
40 CFR 60.470 - Applicability and designation of affected facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.470 Applicability and designation of... mineral handling and storage facility at asphalt roofing plants; and each asphalt storage tank and each blowing still at asphalt processing plants, petroleum refineries, and asphalt roofing plants. (b) Any...
40 CFR 60.470 - Applicability and designation of affected facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.470 Applicability and designation of... mineral handling and storage facility at asphalt roofing plants; and each asphalt storage tank and each blowing still at asphalt processing plants, petroleum refineries, and asphalt roofing plants. (b) Any...
40 CFR 60.470 - Applicability and designation of affected facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.470 Applicability and designation of... mineral handling and storage facility at asphalt roofing plants; and each asphalt storage tank and each blowing still at asphalt processing plants, petroleum refineries, and asphalt roofing plants. (b) Any...
30 CFR 715.19 - Use of explosives.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wells, petroleum or gas-storage facilities, municipal water-storage facilities, fluid-transmission pipelines, gas or oil-collection lines, or water and sewage lines; and (C) 500 feet of an underground mine... explosive materials shall— (i) Have demonstrated a knowledge of, and a willingness to comply with, safety...
46 CFR 525.1 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., warehouse or other terminal facilities in connection with a common carrier, or in connection with a common...; common carriers who perform port terminal services; and warehousemen who operate port terminal facilities... storage spaces, cold storage plants, cranes, grain elevators and/or bulk cargo loading and/or unloading...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-22
... Convenience and Necessity Take notice that on March 4, 2011, Liberty Gas Storage, LLC (Liberty) and LA Storage... Liberty to abandon by transfer certain facilities to LA Storage; (ii) a certificate of public convenience...
Bibliography of Aircraft Gust Measurements in Australia and of Some Related Topics,
1981-09-01
Kf 1972a BUREAU OF METEOROLOGY f/Kf 1972b BUREAU OF METEOROLOGY I/K 1975 BUREAU OF METEOROLOGY f/ T 1977 BUREAU OF METEOROLOGY 1968 BURNHAM, J . 1973...I/Bf 1967 FODEN, P.J. 1977 FREEMAN, W. B. Jr I/RI 1970 FUJITA, T . T . f/Sf 1972 FUJITA, T . T . I/Sf 1977 GARRATT, J.R. f/W/Xf 1969 GENTILLI, J . I/Mf...1956 TROUP, A.J. 1964 KAMIKO, T . 1969 GENTILLI, J . 1970 BERSON, F.A. & LAMOND, M.H. 1972a WARNER, J . 1975 WALKER, D.R. 1976 CHRISTIE, D.R., MUIRHEAr
Conceptual design report: Nuclear materials storage facility renovation. Part 6, Alternatives study
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-07-14
The Nuclear Materials Storage Facility (NMSF) at the Los Alamos National Laboratory (LANL) was a Fiscal Year (FY) 1984 line-item project completed in 1987 that has never been operated because of major design and construction deficiencies. This renovation project, which will correct those deficiencies and allow operation of the facility, is proposed as an FY 97 line item. The mission of the project is to provide centralized intermediate and long-term storage of special nuclear materials (SNM) associated with defined LANL programmatic missions and to establish a centralized SNM shipping and receiving location for Technical Area (TA)-55 at LANL. Based onmore » current projections, existing storage space for SNM at other locations at LANL will be loaded to capacity by approximately 2002. This will adversely affect LANUs ability to meet its mission requirements in the future. The affected missions include LANL`s weapons research, development, and testing (WRD&T) program; special materials recovery; stockpile survelliance/evaluation; advanced fuels and heat sources development and production; and safe, secure storage of existing nuclear materials inventories. The problem is further exacerbated by LANL`s inability to ship any materials offsite because of the lack of receiver sites for material and regulatory issues. Correction of the current deficiencies and enhancement of the facility will provide centralized storage close to a nuclear materials processing facility. The project will enable long-term, cost-effective storage in a secure environment with reduced radiation exposure to workers, and eliminate potential exposures to the public. This report is organized according to the sections and subsections outlined by Attachment 111-2 of DOE Document AL 4700.1, Project Management System. It is organized into seven parts. This document, Part VI - Alternatives Study, presents a study of the different storage/containment options considered for NMSF.« less
Spatial interpolation of gamma dose in radioactive waste storage facility
NASA Astrophysics Data System (ADS)
Harun, Nazran; Fathi Sujan, Muhammad; Zaidi Ibrahim, Mohd
2018-01-01
External radiation measurement for a radioactive waste storage facility in Malaysian Nuclear Agency is a part of Class G License requirement under Atomic Licensing Energy Board (AELB). The objectives of this paper are to obtain the distribution of radiation dose, create dose database and generate dose map in the storage facility. The radiation dose measurement is important to fulfil the radiation protection requirement to ensure the safety of the workers. There are 118 sampling points that had been recorded in the storage facility. The highest and lowest reading for external radiation recorded is 651 microSv/hr and 0.648 microSv/hour respectively. The calculated annual dose shows the highest and lowest reading is 1302 mSv/year and 1.3 mSv/year while the highest and lowest effective dose reading is 260.4 mSv/year and 0.26 mSv/year. The result shows that the ALARA concept along time, distance and shield principles shall be adopted to ensure the dose for the workers is kept below the dose limit regulated by AELB which is 20 mSv/year for radiation workers. This study is important for the improvement of planning and the development of shielding design for the facility.
Pest management in traditional maize stores in West Africa: a farmer's perspective.
Meikle, W G; Markham, R H; Nansen, C; Holst, N; Degbey, P; Azoma, K; Korie, S
2002-10-01
Farmers in the Republic of Benin have few resources to invest in protection of stored maize, and prophylactic pesticide application is often recommended by extension and development agencies. Neither the efficacy nor profitability of such an application in traditional maize storage facilities has been addressed quantitatively. In this study, existing management options for stored maize were evaluated monthly over 6 mo in central and southern Benin with respect to their effects on grain injury and on densities of Prostephanus truncatus (Horn) and Sitophilus zeamais Motschulsky. P. truncatus infested 54% of the experimental stores in the study even though Teretrius nigrescens (Lewis), a natural enemy introduced against P. truncatus, was well established in the region. S. zeamais was the most common pest, found in 85% of the experimental storage facilities. Prophylactically treated maize was, on average, worth more than untreated maize for month 1 through 5 in southern Benin, after taking into account market price, pesticide costs, percentage grain damage and weight loss, but maize storage was not profitable overall. No difference was observed between treatments in central Benin. After 6 mo treated storage facilities were not significantly different from untreated storage facilities in terms of either percentage damage or profit in either region. A rapid scouting plan intended to provide farmers with a means for identifying storage facilities at greatest risk of severe P. truncatus infestation was field validated. Given that unsafe pesticide use is prevalent in Benin, research and extension services should clearly state the limitations to prophylactic treatment and increase the effort to educate farmers on appropriate pesticide use, store monitoring and marketing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brasser, Thomas; Hertes, Uwe; Meyer, Thorsten
2013-07-01
Within the scope of 'Nuclear Security of Radioactive Sources', the German government implemented the modernization of Ukrainian State Production Company's transport and storage facility for radioactive sources (TSF) in Kiev. The overall management of optimizing the physical protection of the storage facility (including the construction of a hot cell for handling the radioactive sources) is currently carried out by the German Federal Foreign Office (AA). AA jointly have assigned Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, Germany's leading expert institution in the area of nuclear safety and waste management, to implement the project and to ensure transparency by financial andmore » technical monitoring. Sealed radioactive sources are widely used in industry, medicine and research. Their life cycle starts with the production and finally ends with the interim/long-term storage of the disused sources. In Ukraine, IZOTOP is responsible for all radioactive sources throughout their life cycle. IZOTOP's transport and storage facility (TSF) is the only Ukrainian storage facility for factory-fresh radioactive sources up to an activity of about 1 million Ci (3.7 1016 Bq). The TSF is specially designed for the storage and handling of radioactive sources. Storage began in 1968, and is licensed by the Ukrainian state authorities. Beside the outdated state of TSF's physical protection and the vulnerability of the facility linked with it, the lack of a hot cell for handling and repacking radioactive sources on the site itself represents an additional potential hazard. The project, financed by the German Federal Foreign Office, aims to significantly improve the security of radioactive sources during their storage and handling at the TSF site. Main tasks of the project are a) the modernization of the physical protection of the TSF itself in order to prevent any unauthorized access to radioactive sources as well as b) the construction of a hot cell to reduce the number of transports of radioactive sources within the city of Kiev. In future, the new established hot cell at IZOTOP's transport and storage facility will be useful for identification and characterization of orphan/disused radioactive sources. The projects implemented are performed in accordance with international recommendations (e. g. IAEA) and national normative documents and will make a crucial contribution towards an improved safety and security management of radioactive sources in Ukraine. (authors)« less
Lessons Learned from Radioactive Waste Storage and Disposal Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esh, David W.; Bradford, Anna H.
2008-01-15
The safety of radioactive waste disposal facilities and the decommissioning of complex sites may be predicated on the performance of engineered and natural barriers. For assessing the safety of a waste disposal facility or a decommissioned site, a performance assessment or similar analysis is often completed. The analysis is typically based on a site conceptual model that is developed from site characterization information, observations, and, in many cases, expert judgment. Because waste disposal facilities are sited, constructed, monitored, and maintained, a fair amount of data has been generated at a variety of sites in a variety of natural systems. Thismore » paper provides select examples of lessons learned from the observations developed from the monitoring of various radioactive waste facilities (storage and disposal), and discusses the implications for modeling of future waste disposal facilities that are yet to be constructed or for the development of dose assessments for the release of decommissioning sites. Monitoring has been and continues to be performed at a variety of different facilities for the disposal of radioactive waste. These include facilities for the disposal of commercial low-level waste (LLW), reprocessing wastes, and uranium mill tailings. Many of the lessons learned and problems encountered provide a unique opportunity to improve future designs of waste disposal facilities, to improve dose modeling for decommissioning sites, and to be proactive in identifying future problems. Typically, an initial conceptual model was developed and the siting and design of the disposal facility was based on the conceptual model. After facility construction and operation, monitoring data was collected and evaluated. In many cases the monitoring data did not comport with the original site conceptual model, leading to additional investigation and changes to the site conceptual model and modifications to the design of the facility. The following cases are discussed: commercial LLW disposal facilities; uranium mill tailings disposal facilities; and reprocessing waste storage and disposal facilities. The observations developed from the monitoring and maintenance of waste disposal and storage facilities provide valuable lessons learned for the design and modeling of future waste disposal facilities and the decommissioning of complex sites.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bibeault, Mark Leonide
This is a proposal to locate a combined Modular Pumped Hydro (MPH) Energy Storage plus PV solar facility at Rio Rancho High School, NM. The facility will functionally provide electricity at night derived from renewable solar energy. Additionally the facility will provide STEM related educational opportunities for students and staff of the school, public community outreach, and validation of an energy storage approach applicable for the Nation (up to 1,000,000 kWh per installation). The proposal will summarize the nature of electricity, why energy storage is useful, present the combined MPH and solar PV production design, present how the actual designmore » will be built and operated in a sustainable manner, how the project could be funded, and how the project could be used in STEM related activities.« less
78 FR 53184 - Land Release for Penn Yan Airport
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-28
... easement of 0.069 +/-acres for ingress/egress to a boat storage and maintenance facility to be constructed.../egress to the Land and Sea Properties boat storage and maintenance facility from the Penn Yan Airport access road. Documents reflecting the Sponsor's request are available, by appointment only, for...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-23
...). C. Group 1 Storage Vessel Affected Facility Control Requirements The final amendments retain the... Control Requirements and Applicability We received comments requesting clarification regarding Group 1... there was confusion regarding the applicability of Group 1 storage vessel affected facility control...
40 CFR 60.433 - Performance test and compliance provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... facilities routinely share the same raw ink storage/handling system with existing facilities, then temporary measurement procedures for segregating the raw inks, related coatings, VOC solvent, and water used at the... the purpose of measuring bulk storage tank quantities of each color of raw ink and each related...
40 CFR 60.433 - Performance test and compliance provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... facilities routinely share the same raw ink storage/handling system with existing facilities, then temporary measurement procedures for segregating the raw inks, related coatings, VOC solvent, and water used at the... the purpose of measuring bulk storage tank quantities of each color of raw ink and each related...
40 CFR 60.433 - Performance test and compliance provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... facilities routinely share the same raw ink storage/handling system with existing facilities, then temporary measurement procedures for segregating the raw inks, related coatings, VOC solvent, and water used at the... the purpose of measuring bulk storage tank quantities of each color of raw ink and each related...
Spatio-temporal distribution of stored-product inects around food processing and storage facilities
USDA-ARS?s Scientific Manuscript database
Grain storage and processing facilities consist of a landscape of indoor and outdoor habitats that can potentially support stored-product insect pests, and understanding patterns of species diversity and spatial distribution in the landscape surrounding structures can provide insight into how the ou...
40 CFR 113.6 - Effect on other laws.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Effect on other laws. 113.6 Section 113.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.6 Effect on other laws. Nothing...
40 CFR 113.6 - Effect on other laws.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 23 2013-07-01 2013-07-01 false Effect on other laws. 113.6 Section 113.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.6 Effect on other laws. Nothing...
40 CFR 113.6 - Effect on other laws.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Effect on other laws. 113.6 Section 113.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.6 Effect on other laws. Nothing...
Learn about how EPA Region 9, Hawaii’s Department of Health, U.S. Navy, and Defense Logistics Agency are working tprotect human health and the environment at the Red Hill Bulk Fuel Storage Facility in Hawaii.
40 CFR 141.714 - Requirements for uncovered finished water storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Requirements for uncovered finished water storage facilities. 141.714 Section 141.714 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Treatment for Cryptosporidium Treatment Technique...
Nuclear Power Plant Security and Vulnerabilities
2009-03-18
Commercial Spent Nuclear Fuel Storage , Public Report...systems that prevent hot nuclear fuel from melting even after the chain reaction has stopped, and storage facilities for highly radioactive spent nuclear ... nuclear fuel cycle facilities must defend against to prevent radiological sabotage and theft of strategic special nuclear material. NRC licensees use
40 CFR 113.6 - Effect on other laws.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Effect on other laws. 113.6 Section 113.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.6 Effect on other laws. Nothing...
40 CFR 113.6 - Effect on other laws.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Effect on other laws. 113.6 Section 113.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR SMALL ONSHORE STORAGE FACILITIES Oil Storage Facilities § 113.6 Effect on other laws. Nothing...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1986-02-01
This Environmental Assessment (EA) supports the DOE proposal to Congress to construct and operate a facility for monitored retrievable storage (MRS) of spent fuel at a site on the Clinch River in the Roane County portion of Oak Ridge, Tennessee. The first part of this document is an assessment of the value of, need for, and feasibility of an MRS facility as an integral component of the waste management system. The second part is an assessment and comparison of the potential environmental impacts projected for each of six site-design combinations. The MRS facility would be centrally located with respect tomore » existing reactors, and would receive and canister spent fuel in preparation for shipment to and disposal in a geologic repository. 207 refs., 57 figs., 132 tabs.« less
An Empirical Analysis of Air Force Food Service Management with Recommendations
1984-02-01
RECEIVING AND STORAGE AREAS Dining facilities must have areas for storage of perishable and nonperishable foods and storage of operational and cleaning ... supplies . Storage areas must be of sufficient size for their intended purpose and must be kept in clean, orderly manner. 1. Expendable Supply Storage: a
Energy Storage Laboratory | Energy Systems Integration Facility | NREL
technologies. Key Infrastructure Energy storage system inverter, energy storage system simulators, research Plug-In Vehicles/Mobile Storage The plug-in vehicles/mobile storage hub includes connections for small integration. Key Infrastructure Ample house power, REDB access, charging stations, easy vehicle parking access
41 CFR 101-28.203-1 - Government storage activity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 2 2013-07-01 2012-07-01 true Government storage... DISTRIBUTION 28.2-Interagency Cross-Servicing in Storage Activities § 101-28.203-1 Government storage activity. A Government activity or facility utilized for the receipt, storage, and issue of supplies...
41 CFR 101-28.203-1 - Government storage activity.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 41 Public Contracts and Property Management 2 2012-07-01 2012-07-01 false Government storage... DISTRIBUTION 28.2-Interagency Cross-Servicing in Storage Activities § 101-28.203-1 Government storage activity. A Government activity or facility utilized for the receipt, storage, and issue of supplies...
77 FR 50101 - Cadeville Gas Storage LLC; Notice of Request Under Blanket Authorization
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-20
... Storage LLC; Notice of Request Under Blanket Authorization On July 27, 2012, Cadeville Gas Storage LLC....213(b) of the Commission's Regulations for authority to construct an additional natural gas storage and injection well at Cadeville's natural gas storage facility in Ouachita Parish, Louisiana. The...
Bible, J; Emery, R J; Williams, T; Wang, S
2006-11-01
Limited permanent low-level radioactive waste (LLRW) disposal capacity and correspondingly high disposal costs have resulted in the creation of numerous interim storage facilities for either decay-in-storage operations or longer term accumulation efforts. These facilities, which may be near the site of waste generation or in distal locations, often were not originally designed for the purpose of LLRW storage, particularly with regard to security. Facility security has become particularly important in light of the domestic terrorist acts of 2001, wherein LLRW, along with many other sources of radioactivity, became recognized commodities to those wishing to create disruption through the purposeful dissemination of radioactive materials. Since some LLRW materials may be in facilities that may exhibit varying degrees of security control sophistication, a security vulnerabilities assessment tool grounded in accepted criminal justice theory and security practice has been developed. The tool, which includes dedicated sections on general security, target hardening, criminalization benefits, and the presence of guardians, can be used by those not formally schooled in the security profession to assess the level of protection afforded to their respective facilities. The tool equips radiation safety practitioners with the ability to methodically and systematically assess the presence or relative status of various facility security aspects, many of which may not be considered by individuals from outside the security profession. For example, radiation safety professionals might not ordinarily consider facility lighting aspects, which is a staple for the security profession since it is widely known that crime disproportionately occurs more frequently at night or in poorly lit circumstances. Likewise, the means and associated time dimensions for detecting inventory discrepancies may not be commonly considered. The tool provides a simple means for radiation safety professionals to assess, and perhaps enhance in a reasonable fashion, the security of their interim storage operations. Aspects of the assessment tool can also be applied to other activities involving the protection of sources of radiation as well.
Supplemental multilayer insulation research facility
NASA Technical Reports Server (NTRS)
Dempsey, P. J.; Stochl, R. J.
1995-01-01
The Supplemental Multilayer Insulation Research Facility (SMIRF) provides a small scale test bed for conducting cryogenic experiments in a vacuum environment. The facility vacuum system is capable of simulating a Space Shuttle launch pressure profile as well as providing a steady space vacuum environment of 1.3 x 10(exp -4) Newton/sq meter (1 x 10(exp -6) torr). Warm side boundary temperatures can be maintained constant between 111 K (200 R) and 361 K (650 R) using a temperature controlled shroud. The shroud can also simulate a typical lunar day-night temperature profile. The test hardware consists of a cryogenic calorimeter supported by the lid of the vacuum chamber. A 0.45 cu meter (120 gallon) vacuum jacketed storage/supply tank is available for conditioning the cryogen prior to use in the calorimeter. The facility was initially designed to evaluate the thermal performance of insulation systems for long-term storage in space. The facility has recently been used to evaluate the performance of various new insulation systems for LH2 and LN2 ground storage dewars.
NASA Astrophysics Data System (ADS)
Zuloaga, P.; Ordoñez, M.; Andrade, C.; Castellote, M.
2011-04-01
The generic design of the centralised spent fuel storage facility was approved by the Spanish Safety Authority in 2006. The planned operational life is 60 years, while the design service life is 100 years. Durability studies and surveillance of the behaviour have been considered from the initial design steps, taking into account the accessibility limitations and temperatures involved. The paper presents an overview of the ageing management program set in support of the Performance Assessment and Safety Review of El Cabril low and intermediate level waste (LILW) disposal facility. Based on the experience gained for LILW, ENRESA has developed a preliminary definition of the Ageing Management Plan for the Centralised Interim Storage Facility of spent Fuel and High Level Waste (HLW), which addresses the behaviour of spent fuel, its retrievability, the confinement system and the reinforced concrete structure. It includes tests plans and surveillance design considerations, based on the El Cabril LILW disposal facility.
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2010 CFR
2010-07-01
... that have been incorporated to minimize loss. The report should make specific reference to appropriate.... Retrofitting may require modifications to the piping system to ensure that adequate water capacity and pressure... storage facilities, boiler rooms or rooms containing equipment operating with a fuel supply (such as...
DOT National Transportation Integrated Search
2017-06-01
The Virginia Department of Transportation (VDOT) collects millions of gallons of runoff at its nearly 300 salt storage : facilities each year, with some portion of this water being reused for the generation of salt brine. Storing this collected storm...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
... critical use included ``processed food, cheese, herbs and spices, and spaces and equipment in associated... inadequately justified and recommended only cheese storage facilities for consideration by the Parties as a... include only ``Members of the National Pest Management Association treating cheese storage facilities...
27 CFR 19.19 - Discontinuance of storage facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... due on the spirits and then to the cost and expense of the sale and removal, and the remaining balance... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Discontinuance of storage facilities. 19.19 Section 19.19 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
... related to operations and maintenance of storage and distribution facilities for petroleum products within the Colton and Colton North Terminals, and with habitat restoration and management on a proposed on... maintenance of storage and distribution facilities for petroleum products on approximately 20 acres (ac) (8...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2012 CFR
2012-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2014 CFR
2014-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
78 FR 27417 - Federal Property Suitable as Facilities To Assist the Homeless
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-10
..., Washington, DC 20593-0001; (202) 475- 5609; NASA: Mr. Frank T. Bellinger, Facilities Engineering Division...: Unutilized Comments: Off-site removal; 1,836 sf.; storage; 60 months vacant; lead-based paint; very poor....; storage; 60 months vacant; very poor conditions; lead-based paint; repairs a must; rodents w/Hanta virus...
This document corrects typographical errors in the regulatory text of the final standards that would limit organic air emissions as a class at hazardous waste treatment, storage, and disposal facilities (TSDF) that are subject to regulation under subtitle
Cost Implications of an Interim Storage Facility in the Waste Management System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarrell, Joshua J.; Joseph, III, Robert Anthony; Howard, Rob L
2016-09-01
This report provides an evaluation of the cost implications of incorporating a consolidated interim storage facility (ISF) into the waste management system (WMS). Specifically, the impacts of the timing of opening an ISF relative to opening a repository were analyzed to understand the potential effects on total system costs.
Lessons Learned from the Puerto Rico Battery Energy Storage System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyes, John D.; De Anda, Mindi Farber; Torres, Wenceslao
1999-08-11
The Puerto Rico Electric Power Authority (PREPA) installed a battery energy storage system in 1994 at a substation near San Juan, Puerto Rico. It was patterned after two other large energy storage systems operated by electric utilities in California and Germany. The Puerto Rico facility is presently the largest operating battery storage system in the world and has successfully provided frequency control, voltage regulation, and spinning reseme to the Caribbean island. The system further proved its usefulness to the PREPA network in the fall of 1998 in the aftermath of Hurricane Georges. However, the facility has suffered accelerated cell failuresmore » in the past year and PREPA is committed to restoring the plant to full capacity. This represents the first repowering of a large utility battery facility. PREPA and its vendors and contractors learned many valuable lessons during all phases of project development and operation, which are summarized in this paper.« less
Fe XXV temperatures in flares from the Yohkoh Bragg crystal spectrometer
NASA Technical Reports Server (NTRS)
Sterling, Alphonse C.; Doschek, George A.; Pike, C. David
1994-01-01
Studies by Doschek et al. using P78-1 and Solar Maximum Misson (SMM) data have shown that the ratio of intensities of the Fe XXV and Ca XIX resonance lines can be expressed as a function of Fe XXV temperature. Using a more recent data set consisting of 13 flares observed by the Bragg crystal spectrometer (BCS) experiment on board Yohkoh, we find a nearly identical functional relationship between the same resonance line ratios and Fe XXV temperatures. We use this functional relationship to obtain resonance line ratio temperatures (T(sub RLR)) for each flare in our data set, and compare them with temperatures resulting from application of a simple spectral fitting method. (T(sub SSF)) to individal Fe XXV spectra. We also use a more involved free-parameter spectral fitting method to deduce temperatures (T(sub FSF)) from some of these spectra. On average, agreement between T(sub RLR) and T(sub SSF) improves as a flare progresses in time, with average agreements of 10.0% +/- 5.2%, 6.4% +/- 5.4%, and 5.0% +/- 3.9% over the rise, peak, and decay phases, respectively. Deviations between T(sub RLR) and T(sub FSF) are about the same or smaller. Thus, for most analysis purposes, all three methods yield virtually identical temperatures in flares. The somewhat poorer agreement between T(sub SSF) and T(sub RLR) during the earlier phases may be partially a result of difficulties in obtaining precise values for temperatures from spectral fits when blueshifts and large nonthermal broadenings are present in the spectra. Because of the high sensitivity of the Yohkoh BCS compared to that of BCS experiments on earlier spacecraft, we can for the first time consistently observe the heating phase of flares in Fe XXV.
Marcon, Magda; Berger, Nicole; Manoliu, Andrei; Fischer, Michael A; Nanz, Daniel; Andreisek, Gustav; Ulbrich, Erika J
2016-04-01
To determine normative values for volume and fat content of the gluteus medius (GMed) and minimus (GMin) muscle in healthy volunteers and to evaluate their dependence on age, gender and leg dominance. The IRB approval was obtained for this study. 80 healthy volunteers (females, 40; males, 40; age range 20-62 years), divided into four age groups, were included. Fat- and water-signal-separated MR images of the pelvis were acquired on a 3.0 T MR with a 3-point mDIXON sequence. Normalized volume and fat-signal fraction (FSF) of the GMed (ViGMed, FSFGMed) and GMin (ViGMin, FSFGMin) muscles were determined. The overall mean volumes (normalized) and FSF ± SD: ViGMed 105.13 ± 16.30 cm(3); ViGMin 30.24 ± 5.15 cm(3); FSFGMed 8.13 ± 1.70 % and FSFGMin 9.89 ± 2.72 %. Comparing different age subgroups within each gender no significant differences were found concerning the volumes and FSFs (except FSFGMin in male subgroup aged 20-29 versus 50-62 years, P = 0.014). Comparing FSFs differences between the two genders, only in 20-29 years subgroup, FSFGMed (P =0.003) and FSFGMin (P =0.002) were greater in female. Volume differences between the two legs were not significant (P > 0.077); FSFGMed and FSFGMin (P =0.005 for both) were significantly lower in the dominant leg in female but not in male group (P = 0.454 for FSFGMed and P = 0.643 for FSFMin). No age dependency was evident for volume normative data for GMed and GMin and normative data for FSF values showed no age- or gender dependency.
Advanced long term cryogenic storage systems
NASA Technical Reports Server (NTRS)
Brown, Norman S.
1987-01-01
Long term, cryogenic fluid storage facilities will be required to support future space programs such as the space-based Orbital Transfer Vehicle (OTV), Telescopes, and Laser Systems. An orbital liquid oxygen/liquid hydrogen storage system with an initial capacity of approximately 200,000 lb will be required. The storage facility tank design must have the capability of fluid acquisition in microgravity and limit cryogen boiloff due to environmental heating. Cryogenic boiloff management features, minimizing Earth-to-orbit transportation costs, will include advanced thick multilayer insulation/integrated vapor cooled shield concepts, low conductance support structures, and refrigeration/reliquefaction systems. Contracted study efforts are under way to develop storage system designs, technology plans, test article hardware designs, and develop plans for ground/flight testing.
76 FR 41235 - Tres Palacios Gas Storage LLC; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-13
... Gas Storage LLC; Notice of Application Take notice that on July 5, 2011, Tres Palacios Gas Storage LLC.... CP07-90-000; authorizing TPGS to implement limited changes to the certificated Tres Palacios Storage... existing footprint of the Tres Palacios Storage Facility on previous cleared land. TPGS does not propose...
Battery and Thermal Energy Storage | Energy Systems Integration Facility |
NREL Battery and Thermal Energy Storage Battery and Thermal Energy Storage Not long ago, the performance of grid-integrated battery and thermal energy storage technologies. Photo of a battery energy . NREL is also creating better materials for batteries and thermal storage devices to improve their
A central storage facility to reduce pesticide suicides--a feasibility study from India.
Vijayakumar, Lakshmi; Jeyaseelan, Lakshmanan; Kumar, Shuba; Mohanraj, Rani; Devika, Shanmugasundaram; Manikandan, Sarojini
2013-09-16
Pesticide suicides are considered the single most important means of suicide worldwide. Centralized pesticide storage facilities have the possible advantage of delaying access to pesticides thereby reducing suicides. We undertook this study to examine the feasibility and acceptability of a centralized pesticide storage facility as a preventive intervention strategy in reducing pesticide suicides. A community randomized controlled feasibility study using a mixed methods approach involving a household survey; focus group discussions (FGDs) and surveillance were undertaken. The study was carried out in a district in southern India. Eight villages that engaged in floriculture were identified. Using the lottery method two were randomized to be the intervention sites and two villages constituted the control site. Two centralized storage facilities were constructed with local involvement and lockable storage boxes were constructed. The household survey conducted at baseline and one and a half years later documented information on sociodemographic data, pesticide usage, storage and suicides. At baseline 4446 individuals (1097 households) in the intervention and 3307 individuals (782 households) in the control sites were recruited while at follow up there were 4308 individuals (1063 households) in the intervention and 2673 individuals (632 households) in the control sites. There were differences in baseline characteristics and imbalances in the prevalence of suicides between intervention and control sites as this was a small feasibility study.The results from the FGDs revealed that most participants found the storage facility to be both useful and acceptable. In addition to protecting against wastage, they felt that it had also helped prevent pesticide suicides as the pesticides stored here were not as easily and readily accessible. The primary analyses were done on an Intention to Treat basis. Following the intervention, the differences between sites in changes in combined, completed and attempted suicide rates per 100,000 person-years were 295 (95% CI: 154.7, 434.8; p < 0.001) for pesticide suicide and 339 (95% CI: 165.3, 513.2, p < 0.001) for suicide of all methods. Suicide by pesticides poisoning is a major public health problem and needs innovative interventions to address it. This study, the first of its kind in the world, examined the feasibility of a central storage facility as a means of limiting access to pesticides and, has provided preliminary results on its usefulness. These results need to be interpreted with caution in view of the imbalances between sites. The facility was found to be acceptable, thereby underscoring the need for larger studies for a longer duration. ISRCTN04912407.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schruder, Kristan; Goodwin, Derek
2013-07-01
AECL's Fuel Packaging and Storage (FPS) Project was initiated in 2004 to retrieve, transfer, and stabilize an identified inventory of degraded research reactor fuel that had been emplaced within in-ground 'Tile Hole' structures in Chalk River Laboratories' Waste Management Area in the 1950's and 60's. Ongoing monitoring of the legacy fuel storage conditions had identified that moisture present in the storage structures had contributed to corrosion of both the fuel and the storage containers. This prompted the initiation of the FPS Project which has as its objective to design, construct, and commission equipment and systems that would allow for themore » ongoing safe storage of this fuel until a final long-term management, or disposition, pathway was available. The FPS Project provides systems and technologies to retrieve and transfer the fuel from the Waste Management Area to a new facility that will repackage, dry, safely store and monitor the fuel for a period of 50 years. All equipment and the new storage facility are designed and constructed to meet the requirements for Class 1 Nuclear Facilities in Canada. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, D.; Ascanio, X.
1996-05-01
The Department of Energy has issued a technical standard for long-term (>50 years) storage and will soon issue a criteria document for interim (<20 years) storage of plutonium materials. The long-term technical standard, {open_quotes}Criteria for Safe Storage of Plutonium Metals and Oxides,{close_quotes} addresses the requirements for storing metals and oxides with greater than 50 wt % plutonium. It calls for a standardized package that meets both off-site transportation requirements, as well as remote handling requirements from future storage facilities. The interim criteria document, {open_quotes}Criteria for Interim Safe Storage of Plutonium-Bearing Solid Materials{close_quotes}, addresses requirements for storing materials with less thanmore » 50 wt% plutonium. The interim criteria document assumes the materials will be stored on existing sites, and existing facilities and equipment will be used for repackaging to improve the margin of safety.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-12-01
The Strategic Petroleum Reserve (SPR) Weeks Island site is one of five underground salt dome crude oils storage facilities operated by the Department of Energy (DOE). It is located in Iberia Parish, Louisiana. The purpose of the proposed action is to decommission the Weeks Island crude oil storage after the oil inventory has been transferred to other SPR facilities. Water intrusion into the salt dome storage chambers and the development of two sinkholes located near the aboveground facilities has created uncertain geophysical conditions. This Environmental Assessment describes the proposed decommissioning operation, its alternatives, and potential environmental impacts. Based on thismore » analyses, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) and has issued the Finding of No Significant Impact (FONSI).« less
The Time Needed to Implement the Blue Ribbon Commission Recommendation on Interim Storage - 13124
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voegele, Michael D.; Vieth, Donald
2013-07-01
The report of the Blue Ribbon Commission on America's Nuclear Future [1] makes a number of important recommendations to be considered if Congress elects to redirect U.S. high-level radioactive waste disposal policy. Setting aside for the purposes of this discussion any issues related to political forces leading to stopping progress on the Yucca Mountain project and driving the creation of the Commission, an important recommendation of the Commission was to institute prompt efforts to develop one or more consolidated storage facilities. The Blue Ribbon Commission noted that this recommended strategy for future storage and disposal facilities and operations should bemore » implemented regardless of what happens with Yucca Mountain. It is too easy, however, to focus on interim storage as an alternative to geologic disposal. The Blue Ribbon Commission report does not go far enough in addressing the magnitude of the contentious problems associated with reopening the issues of relative authorities of the states and federal government with which Congress wrestled in crafting the Nuclear Waste Policy Act [2]. The Blue Ribbon Commission recommendation for prompt adoption of an interim storage program does not appear to be fully informed about the actions that must be taken, the relative cost of the effort, or the realistic time line that would be involved. In essence, the recommendation leaves to others the details of the systems engineering analyses needed to understand the nature and details of all the operations required to reach an operational interim storage facility without derailing forever the true end goal of geologic disposal. The material presented identifies a number of impediments that must be overcome before the country could develop a centralized federal interim storage facility. In summary, and in the order presented, they are: 1. Change the law, HJR 87, PL 107-200, designating Yucca Mountain for the development of a repository. 2. Bring new nuclear waste legislation to the floor of the Senate, overcoming existing House support for Yucca Mountain; 3. Change the longstanding focus of Congress from disposal to storage; 4. Change the funding concepts embodied in the Nuclear Waste Policy Act to allow the Nuclear Waste fund to be used to pay for interim storage; 5. Reverse the Congressional policy not to give states or tribes veto or consent authority, and to reserve to Congress the authority to override a state or tribal disapproval; 6. Promulgate interim storage facility siting regulations to reflect the new policies after such changes to policy and law; 7. Complete already underway changes to storage and transportation regulations, possibly incorporating changes to reflect changes to waste disposal law; 8. Promulgate new repository siting regulations if the interim storage facility is to support repository development; 9. Identify volunteer sites, negotiate agreements, and get Congressional approval for negotiated benefits packages; 10. Design, License and develop the interim storage facility. The time required to accomplish these ten items depends on many factors. The estimate developed assumes that certain of the items must be completed before other items are started; given past criticisms of the current program, such an assumption appears appropriate. Estimated times for completion of individual items are based on historical precedent. (authors)« less
Hanford facility dangerous waste permit application, general information portion. Revision 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonnichsen, J.C.
1997-08-21
For purposes of the Hanford facility dangerous waste permit application, the US Department of Energy`s contractors are identified as ``co-operators`` and sign in that capacity (refer to Condition I.A.2. of the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit). Any identification of these contractors as an ``operator`` elsewhere in the application is not meant to conflict with the contractors` designation as co-operators but rather is based on the contractors` contractual status with the U.S. Department of Energy, Richland Operations Office. The Dangerous Waste Portion of the initial Hanford Facility Resource Conservation and Recovery Act Permit,more » which incorporated five treatment, storage, and/or disposal units, was based on information submitted in the Hanford Facility Dangerous Waste Permit Application and in closure plan and closure/postclosure plan documentation. During 1995, the Dangerous Waste Portion was modified twice to incorporate another eight treatment, storage, and/or disposal units; during 1996, the Dangerous Waste Portion was modified once to incorporate another five treatment, storage, and/or disposal units. The permit modification process will be used at least annually to incorporate additional treatment, storage, and/or disposal units as permitting documentation for these units is finalized. The units to be included in annual modifications are specified in a schedule contained in the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit. Treatment, storage, and/or disposal units will remain in interim status until incorporated into the Permit. The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (this document, DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to individual operating treatment, storage, and/or disposal units for which Part B permit application documentation has been, or is anticipated to be, submitted. Documentation for treatment, storage, and/or disposal units undergoing closure, or for units that are, or are anticipated to be, dispositioned through other options, will continue to be submitted by the Permittees in accordance with the provisions of the Hanford Federal Facility Agreement and Consent Order. However, the scope of the General Information Portion includes information that could be used to discuss operating units, units undergoing closure, or units being dispositioned through other options. Both the General Information and Unit-Specific portions of the Hanford Facility Dangerous Waste Permit Application address the contents of the Part B permit application guidance documentation prepared by the Washington State Department of Ecology and the U.S. Environmental Protection Agency, with additional information needs defined by revisions of Washington Administrative Code 173-303 and by the Hazardous and Solid Waste Amendments. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (i.e., either operating units, units undergoing closure, or units being dispositioned through other options).« less
1990-09-01
Kedl is associated with the Oak Ridge National Laboratory ( ORNL ). The technical editor was Gloria J. Wienke, Information Management Office, USACERL. COL...of a DIS cooling system for Building 506, a barracks/ office/dining facility. Oak Ridge National Laboratory ( ORNL ) designed the system in cooperation... ORNL with assistance from YPG and analyzed by USACERL. R.J. Kedl and C.W. Sohn, As.vsment of Energy Storage Technologies for Army Facilities, Technical
Operation of the 25kW NASA Lewis Research Center Solar Regenerative Fuel Cell Tested Facility
NASA Technical Reports Server (NTRS)
Moore, S. H.; Voecks, G. E.
1997-01-01
Assembly of the NASA Lewis Research Center(LeRC)Solar Regenerative Fuel Cell (RFC) Testbed Facility has been completed and system testing has proceeded. This facility includes the integration of two 25kW photovoltaic solar cell arrays, a 25kW proton exchange membrane (PEM) electrolysis unit, four 5kW PEM fuel cells, high pressure hydrogen and oxygen storage vessels, high purity water storage containers, and computer monitoring, control and data acquisition.
Environmental Projects. Volume 9: Construction of hazardous materials storage facilities
NASA Technical Reports Server (NTRS)
1989-01-01
Activities at the Goldstone Deep Space Communications Complex (GDSCC) are carried out in support of seven parabolic dish antennas. These activities may give rise to environmental hazards. This report is one in a series of reports describing environmental projects at GDSCC. The construction of two hazardous materials and wastes storage facilities and an acid-wash facility is described. An overview of the Goldstone complex is also presented along with a description of the environmental aspects of the GDSCC site.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Administration, Modern Records Programs (NWM), 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301... agency meet before it transfers records to a records storage facility? 1232.14 Section 1232.14 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Administration, Modern Records Programs (NWM), 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301... agency meet before it transfers records to a records storage facility? 1232.14 Section 1232.14 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Administration, Modern Records Programs (NWM), 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301... agency meet before it transfers records to a records storage facility? 1232.14 Section 1232.14 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT TRANSFER OF...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
... licenses for nuclear power plants and spent fuel storage facilities from the current holder, Constellation... Independent Spent Fuel Storage Installation (ISFSI) Materials License No. SNM-2505; Nine Mile Point Nuclear.... A request for a hearing must be filed by January 15, 2014. Any potential party as defined in Sec. 2...
36 CFR § 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2013 CFR
2013-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
10 CFR 62.13 - Contents of a request for emergency access: Alternatives.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EMERGENCY ACCESS TO NON-FEDERAL AND REGIONAL LOW-LEVEL WASTE DISPOSAL FACILITIES Request for a Commission... following: (1) Storage of low-level radioactive waste at the site of generation; (2) Storage of low-level... disposal at a Federal low-level radioactive waste disposal facility in the case of a Federal or defense...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000 barrels or less capacity. 113.4 Section 113.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000 barrels or less capacity. 113.4 Section 113.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR...
Low emittance lattice for the storage ring of the Turkish Light Source Facility TURKAY
NASA Astrophysics Data System (ADS)
Nergiz, Z.; Aksoy, A.
2015-06-01
The TAC (Turkish Accelerator Center) project aims to build an accelerator center in Turkey. The first stage of the project is to construct an Infra-Red Free Electron Laser (IR-FEL) facility. The second stage is to build a synchrotron radiation facility named TURKAY, which is a third generation synchrotron radiation light source that aims to achieve a high brilliance photon beam from a low emittance electron beam at 3 GeV. The electron beam parameters are highly dependent on the magnetic lattice of the storage ring. In this paper a low emittance storage ring for TURKAY is proposed and the beam dynamic properties of the magnetic lattice are investigated. Supported by Turkish Republic Ministry of Development (DPT2006K120470)
40 CFR 246.202-4 - Recommended procedures: Methods of separation and storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... which the corrugated accumulates, the storage capacity of the facility, and the projected cost-effectiveness of using the various methods. All of the following suggested modes of separation and storage...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
Gillijns, W; Aladyshkin, A Yu; Lange, M; Van Bael, M J; Moshchalkov, V V
2005-11-25
Domain-wall superconductivity is studied in a superconducting Nb film placed between two ferromagnetic Co/Pd multilayers with perpendicular magnetization. The parameters of top and bottom ferromagnetic films are chosen to provide different coercive fields, so that the magnetic domain structure of the ferromagnets can be selectively controlled. From the dependence of the critical temperature Tc on the applied magnetic field H, we have found evidence for domain-wall superconductivity in this three-layered F/S/F structure for different magnetic domain patterns. The phase boundary, calculated numerically for this structure from the linearized Ginzburg-Landau equation, is in good agreement with the experimental data.
The 1991 Neural Information Processing Systems-natural & Synthetic
1993-02-01
AL, 3(1 SEP P’ 4. TITLE AND SUBTITLE • 5 A. -’,c- - THE 1ඣ NEURNI. INFORLATION PROCESS r.’FC ,SY.;TEMS--NAFIJL & SYNTHFT [C -IU’) 6. AUTHOR( S ...Professor john loodv D T C. FSF S - .IAV rl PrTIC" 7. PERFORMING ORGANIZATION NAME( S ) A RS U ,r" ’ " 7 -" - ,’MAY 14 1993, REPORT NUV8B-; ,CcInpllt er Sc...enCle NEW Ha Ver: c 66520-21.58 ,"- 9 SPONSORING,, MONITORING AGENCY NAME( S ) AND ADORESS(ES) 10 SPCNSOR;NG VC%- h’ AFOSRi’NM AGENCY R[POwT N ’,řF
Detail of bricked up storage vault opening Central of ...
Detail of bricked up storage vault opening - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Brick Storage Vaults under Jones Street, Bounded by West Broad, Jones, West Boundary & Hull Streets, Savannah, Chatham County, GA
Aliso Canyon facility is giant among gas storage projects. [Underground
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magruder, P.S.
1975-11-01
Alison Canyon, the largest and newest of the Southern California Gas Company's underground storage fields, has the capacity to provide nearly 50 percent of the company's firm peak day deliverability from systemwide storage. (LK)
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric substations and liquid storage...
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric substations and liquid storage...
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric substations and liquid storage...
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric substations and liquid storage...
49 CFR 193.2181 - Impoundment capacity: LNG storage tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS Design Impoundment Design and Capacity § 193.2181 Impoundment capacity: LNG storage tanks. Each impounding system serving an LNG storage tank must have a... 49 Transportation 3 2010-10-01 2010-10-01 false Impoundment capacity: LNG storage tanks. 193.2181...
PLOT PLAN OF FUEL STORAGE BUILDING (CPP603) SHOWING STORAGE BASINS ...
PLOT PLAN OF FUEL STORAGE BUILDING (CPP-603) SHOWING STORAGE BASINS AND PROPOSED LOCATION OF FUEL ELEMENT CUTTING FACILITY. INL DRAWING NUMBER 200-0603-00-706-051287. ALTERNATE ID NUMBER CPP-C-1287. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
9 CFR 590.549 - Dried egg storage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Dried egg storage. 590.549 Section 590.549 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG..., and Facility Requirements § 590.549 Dried egg storage. Dried egg storage shall be sufficient to...
49 CFR 193.2623 - Inspecting LNG storage tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Inspecting LNG storage tanks. 193.2623 Section 193... GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2623 Inspecting LNG storage tanks. Each LNG storage tank must be inspected or tested to verify that each of the following conditions does not impair...
9 CFR 590.549 - Dried egg storage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Dried egg storage. 590.549 Section 590.549 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG..., and Facility Requirements § 590.549 Dried egg storage. Dried egg storage shall be sufficient to...
75 FR 57011 - Tallulah Gas Storage LLC; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... Storage LLC; Notice of Application September 9, 2010. Take notice that on August 31, 2010, Tallulah Gas Storage LLC (Tallulah), 10370 Richmond Avenue, Suite 510, Houston, TX 77042, filed in Docket No. CP10-494... necessity authorizing Tallulah to construct and operate a natural gas storage facility and pipeline...
75 FR 17707 - Arlington Storage Company, LLC; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-07
... Storage Company, LLC; Notice of Filing March 30, 2010. Take notice that on March 24, 2010, Arlington Storage Company, LLC (ASC), Two Brush Creek Boulevard, Kansas City, Missouri 64112, filed an application... existing underground natural gas storage facility located in Schuyler County, New York known as the Seneca...
49 CFR 193.2623 - Inspecting LNG storage tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Inspecting LNG storage tanks. 193.2623 Section 193... GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2623 Inspecting LNG storage tanks. Each LNG storage tank must be inspected or tested to verify that each of the following conditions does not impair...
78 FR 30918 - Perryville Gas Storage LLC; Notice of Request Under Blanket Authorization
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-23
... Storage LLC; Notice of Request Under Blanket Authorization Take notice that on May 3, 2013, Perryville Gas Storage LLC (Perryville), Three Riverway, Suite 1350, Houston, Texas 77056, filed a prior notice request... Perryville's natural gas storage facility in Franklin and Richland Parishes, Louisiana. Perryville does not...
9 CFR 590.549 - Dried egg storage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Dried egg storage. 590.549 Section 590.549 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG..., and Facility Requirements § 590.549 Dried egg storage. Dried egg storage shall be sufficient to...
49 CFR 193.2623 - Inspecting LNG storage tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Inspecting LNG storage tanks. 193.2623 Section 193... GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2623 Inspecting LNG storage tanks. Each LNG storage tank must be inspected or tested to verify that each of the following conditions does not impair...
Waste Encapsulation and Storage Facility (WESF) Dangerous Waste Training Plan (DWTP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
SIMMONS, F.M.
2000-03-29
This Waste Encapsulation Storage Facility (WESF) Dangerous Waste Training Plan (DWTP) applies to personnel who perform work at, or in support of WESF. The plan, along with the names of personnel, may be given to a regulatory agency inspector upon request. General workers, subcontractors, or visiting personnel who have not been trained in the management of dangerous wastes must be accompanied by an individual who meets the requirements of this training plan. Dangerous waste management includes handling, treatment, storage, and/or disposal of dangerous and/or mixed waste. Dangerous waste management units covered by this plan include: less-than-90-day accumulation area(s); pool cellsmore » 1-8 and 12 storage units; and process cells A-G storage units. This training plan describes general requirements, worker categories, and provides course descriptions for operation of the WESF permitted miscellaneous storage units and the Less-than-90-Day Accumulation Areas.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, L. M.; Environmental Science Division
In 1997, low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5 {micro}g/L) were detected in groundwater at Inman, Kansas, by the Kansas Department of Health and Environment (KDHE). The 1997 KDHE sampling was conducted under the U.S. Department of Agriculture (USDA) private well sampling program. The Commodity Credit Corporation (CCC), a USDA agency, operated a grain storage facility in Inman from 1954 to 1965. Carbon tetrachloride is the contaminant of primary concern at sites associated with former CCC/USDA grain storage operations. Inman is located in southwest McPherson County, approximately 10 mi southwest of the city ofmore » McPherson (Figure 1.1). To determine whether the former CCC/USDA facility at Inman is a potential contaminant source and its possible relationship to the contamination in groundwater, the CCC/USDA has agreed to conduct an investigation at Inman, in accordance with the Intergovernmental Agreement between the KDHE and the Farm Service Agency of the USDA. For this work plan, Argonne compiled historical data related to the previous investigations and grain storage operations at Inman. Through a review of documents acquired from all available sources, other potential contaminant source areas (in addition to the former CCC/USDA facility) have been identified as (1) the commercial grain storage structures northwest of Inman, along the railroad right-of-way, and (2) small former private grain storage facilities west of Main Street and near the former CCC/USDA facility at the southern edge of Inman (Figure 1.2). Previous investigations and the potential source areas are discussed in Section 2.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Facilities. 351.10 Section 351.10... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Facilities and Operations § 351.10 Facilities. (a) Facilities for the preparation, identification, and storage of the technical animal fat to be...
40 CFR 60.434 - Monitoring of operations and recordkeeping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... affected facility using waterborne ink systems or solvent-borne ink systems with solvent recovery systems...) If affected facilities share the same raw ink storage/handling system with existing facilities...
40 CFR 60.434 - Monitoring of operations and recordkeeping.
Code of Federal Regulations, 2014 CFR
2014-07-01
... affected facility using waterborne ink systems or solvent-borne ink systems with solvent recovery systems...) If affected facilities share the same raw ink storage/handling system with existing facilities...
40 CFR 60.434 - Monitoring of operations and recordkeeping.
Code of Federal Regulations, 2013 CFR
2013-07-01
... affected facility using waterborne ink systems or solvent-borne ink systems with solvent recovery systems...) If affected facilities share the same raw ink storage/handling system with existing facilities...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Modern Records Programs (NWM), 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... agency create before it transfers records to a records storage facility? § 1232.16 Section § 1232.16 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT...
Code of Federal Regulations, 2013 CFR
2013-07-01
...), National Archives and Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number... Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837-1867. The... authority to establish or relocate records storage facilities? § 1234.30 Section § 1234.30 Parks, Forests...
Evaluation of Radiation Impacts of Spent Nuclear Fuel Storage (SNFS-2) of Chernobyl NPP - 13495
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paskevych, Sergiy; Batiy, Valiriy; Sizov, Andriy
2013-07-01
Radiation effects are estimated for the operation of a new dry storage facility for spent nuclear fuel (SNFS-2) of Chernobyl NPP RBMK reactors. It is shown that radiation exposure during normal operation, design and beyond design basis accidents are minor and meet the criteria for safe use of radiation and nuclear facilities in Ukraine. (authors)
RCRA Refresher Self-Study, Course 28582
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, Lewis Edward
Federal and state regulations require hazardous and mixed waste facility workers at treatment and storage facilities (TSFs) and <90-day accumulation areas to be trained in hazardous and mixed waste management. This course will refamiliarize and update <90-day accumulation area workers, TSF workers, and supervisors of TSF workers regarding waste identification, pollution prevention, storage area requirements, emergency response procedures, and record-keeping requirements.
RCRA Personnel Training, Course 7488
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, Lewis Edward
Federal and state regulations require hazardous and mixed waste facility workers at treatment and storage facilities (TSFs) and <90-day accumulation areas to be trained in hazardous and mixed waste management. This course will refamiliarize and update <90-day accumulation area workers, TSF workers, and supervisors of TSF workers regarding waste identification, pollution prevention, storage area requirements, emergency response procedures, and record-keeping requirements.
High-Performance Computing User Facility | Computational Science | NREL
User Facility High-Performance Computing User Facility The High-Performance Computing User Facility technologies. Photo of the Peregrine supercomputer The High Performance Computing (HPC) User Facility provides Gyrfalcon Mass Storage System. Access Our HPC User Facility Learn more about these systems and how to access
Structural and seismic analyses of waste facility reinforced concrete storage vaults
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, C.Y.
1995-07-01
Facility 317 of Argonne National Laboratory consists of several reinforced concrete waste storage vaults designed and constructed in the late 1940`s through the early 1960`s. In this paper, structural analyses of these concrete vaults subjected to various natural hazards are described, emphasizing the northwest shallow vault. The natural phenomenon hazards considered include both earthquakes and tornados. Because these vaults are deeply embedded in the soil, the SASSI (System Analysis of Soil-Structure Interaction) code was utilized for the seismic calculations. The ultimate strength method was used to analyze the reinforced concrete structures. In all studies, moment and shear strengths at criticalmore » locations of the storage vaults were evaluated. Results of the structural analyses show that almost all the waste storage vaults meet the code requirements according to ACI 349--85. These vaults also satisfy the performance goal such that confinement of hazardous materials is maintained and functioning of the facility is not interrupted.« less
The Yami`s opposition to the Lanyu LLW storage installation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K.K.; Chang, S.Y.
1993-12-31
Since 1982, the solidified low-level radioactive wastes (LLW) in Taiwan, regardless of the origins, have been sent to Lanyu for interim storage. Lanyu is a small island located 80 kilometers southeast of Taiwan. Its unique Polynesian cultural characteristics make it an attractive tourist spot. Dissatisfaction of being the commonly neglected powerless minority, in addition to the political claims from the outside environmental activists made the majority of the Lanyu residents oppose the operation of the storage facility. Approximately 80,000 drums of these wastes have been sent to Lanyu. Although the radiological monitoring results demonstrated that the current operation causes negligiblemore » impact on the environment. Accounting for the fast changing social and political situations in Taiwan today, without a good public acceptance program for both sides, the continuous operation of the Lanyu LLW storage facility until the year 2002, at which time the LLW disposal facility will be commissioned, could be in limbo.« less
Characterization of neutron sources from spent fuel casks. [Skyshine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parks, C.V.; Pace, J.V. III
1987-01-01
In the interim period prior to the acceptance of spent fuel for disposal by the USDOE, utilities are beginning to choose dry cask storage as an alternative to pool re-racking, transshipments, or new pool construction. In addition, the current MRS proposal calls for interim dry storage of consolidated spent fuel in concrete casks. As part of the licensing requirements for these cask storage facilities, calculations are typically necessary to determine the yearly radiation dose received at the site boundary. Unlike wet facilities, neutron skyshine can be an important contribution to the total boundary dose from a dry storage facility. Calculationmore » of the neutron skyshine is in turn heavily dependent on the source characteristics and source model selected for the analysis. This paper presents the basic source characteristics of the spent fuel stored in dry casks and discusses factors that must be considered in evaluating and modeling the radiation sources for the subsequent skyshine calculation. 4 refs., 1 tab.« less
40 CFR 60.400 - Applicability and designation of affected facility.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...
40 CFR 60.400 - Applicability and designation of affected facility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...
40 CFR 60.400 - Applicability and designation of affected facility.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...
40 CFR 60.400 - Applicability and designation of affected facility.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...
40 CFR 60.400 - Applicability and designation of affected facility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...
Take a Tour of Our Facility | Energy Systems Integration Facility | NREL
Take a Tour of Our Facility Take a Tour of Our Facility The Energy Systems Integration Facility Optical Characterization Laboratory System Performance Laboratory Power Systems Integration Laboratory Control Room Energy Storage Laboratory Outdoor Testing Areas Outdoor Testing Areas Energy Systems
USDA-ARS?s Scientific Manuscript database
Hermetic storage is of interest to farmers and warehouse managers as a method to control insect pests in small storage facilities. To develop improved understanding of effects of hermetic storage on insect pest activity and mortality over time, oxygen levels, acoustic signals, and observations of vi...
40 CFR 63.8985 - Am I subject to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... production facility includes all HCl storage tanks that contain liquid HCl product that is produced in the... service used to transfer liquid HCl product from the HCl production unit to the HCl storage tanks and/or... site via pipeline. (2) Storage tanks that are dedicated feedstock tanks for another process and storage...
40 CFR 761.63 - PCB household waste storage and disposal.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false PCB household waste storage and..., AND USE PROHIBITIONS Storage and Disposal § 761.63 PCB household waste storage and disposal. PCB household waste, as defined at § 761.3, managed in a facility permitted, licensed, or registered by a State...
40 CFR 761.63 - PCB household waste storage and disposal.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false PCB household waste storage and..., AND USE PROHIBITIONS Storage and Disposal § 761.63 PCB household waste storage and disposal. PCB household waste, as defined at § 761.3, managed in a facility permitted, licensed, or registered by a State...
40 CFR 761.63 - PCB household waste storage and disposal.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false PCB household waste storage and..., AND USE PROHIBITIONS Storage and Disposal § 761.63 PCB household waste storage and disposal. PCB household waste, as defined at § 761.3, managed in a facility permitted, licensed, or registered by a State...
40 CFR 761.63 - PCB household waste storage and disposal.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false PCB household waste storage and..., AND USE PROHIBITIONS Storage and Disposal § 761.63 PCB household waste storage and disposal. PCB household waste, as defined at § 761.3, managed in a facility permitted, licensed, or registered by a State...
21 CFR 1250.83 - Storage of water prior to treatment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Storage of water prior to treatment. 1250.83... CONVEYANCE SANITATION Sanitation Facilities and Conditions on Vessels § 1250.83 Storage of water prior to treatment. The following requirements with respect to the storage of water on vessels prior to treatment...
21 CFR 1250.83 - Storage of water prior to treatment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Storage of water prior to treatment. 1250.83... CONVEYANCE SANITATION Sanitation Facilities and Conditions on Vessels § 1250.83 Storage of water prior to treatment. The following requirements with respect to the storage of water on vessels prior to treatment...
40 CFR 761.63 - PCB household waste storage and disposal.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false PCB household waste storage and..., AND USE PROHIBITIONS Storage and Disposal § 761.63 PCB household waste storage and disposal. PCB... to manage municipal or industrial solid waste, or in a facility with an approval to dispose of PCB...
77 FR 789 - Tres Palacios Gas Storage LLC; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-06
... Gas Storage LLC; Notice of Application Take notice that on December 20, 2011, Tres Palacios Gas Storage LLC (Tres Palacios), Two Brush Creek Boulevard, Kansas City, Missouri 64112, filed in the above... on its storage facility header pipeline system by: (i) Constructing a 19.7-mile, 24-inch diameter...
Shittu, Ekundayo; Harnly, Melissa; Whitaker, Shanta; Miller, Roger
2016-02-01
One of the major problems facing Nigeria's vaccine supply chain is the lack of adequate vaccine storage facilities. Despite the introduction of solar-powered refrigerators and the use of new tools to monitor supply levels, this problem persists. Using data on vaccine supply for 2011-14 from Nigeria's National Primary Health Care Development Agency, we created a simulation model to explore the effects of variance in supply and demand on storage capacity requirements. We focused on the segment of the supply chain that moves vaccines inside Nigeria. Our findings suggest that 55 percent more vaccine storage capacity is needed than is currently available. We found that reorganizing the supply chain as proposed by the National Primary Health Care Development Agency could reduce that need to 30 percent more storage. Storage requirements varied by region of the country and vaccine type. The Nigerian government may want to consider the differences in storage requirements by region and vaccine type in its proposed reorganization efforts. Project HOPE—The People-to-People Health Foundation, Inc.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Facilities and Operations § 351.10 Facilities. (a) Facilities for the preparation, identification, and storage of the technical animal fat to be... maintain the identity of certified technical animal fats and materials used in their preparation, and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Facilities and Operations § 351.10 Facilities. (a) Facilities for the preparation, identification, and storage of the technical animal fat to be... maintain the identity of certified technical animal fats and materials used in their preparation, and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Facilities and Operations § 351.10 Facilities. (a) Facilities for the preparation, identification, and storage of the technical animal fat to be... maintain the identity of certified technical animal fats and materials used in their preparation, and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Facilities and Operations § 351.10 Facilities. (a) Facilities for the preparation, identification, and storage of the technical animal fat to be... maintain the identity of certified technical animal fats and materials used in their preparation, and...
Microbial Community Analysis in Water Storage Tank Sediment Exposed to Monochloramine - Portland
Sediment accumulation in water storage facilities causes water quality degradation, including enhanced biological growth and more rapid disinfectant decay. The current research evaluated the microbial community composition after a drinking water storage facility’s sediment was e...
Fuel Storage Tanks at FAA Facilities: Order 1050.15A
DOT National Transportation Integrated Search
1997-04-30
The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its : inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for : emergency backup generators providing secondary power to air navigati...
Microbial Community Analysis in Water Storage Tank Sediment Exposed to Monochloramine
Sediment accumulation in water storage facilities causes water quality degradation, including enhanced biological growth and more rapid disinfectant decay. The current research evaluated the microbial community composition after a drinking water storage facility’s sediment was e...
Downgrading Nuclear Facilities to Radiological Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarry, Jeffrey F.; Farr, Jesse Oscar; Duran, Leroy
2015-08-01
Based on inventory reductions and the use of alternate storage facilities, the Sandia National Laboratories (SNL) downgraded 4 SNL Hazard Category 3 (HC-3) nuclear facilities to less-than-HC-3 radiological facilities. SNL’s Waste Management and Pollution Prevention Department (WMPPD) managed the HC-3 nuclear facilities and implemented the downgrade. This paper will examine the downgrade process,
ERIC Educational Resources Information Center
Walker, Ben
2008-01-01
In August 2007, an $11.2 million proposal for a shared statewide high-density storage facility was submitted to the Board of Governors, the governing body of the State University System in Florida. The project was subsequently approved at a slightly lower level and funding was delayed until 2010/2011. The experiences of coordinating data…
1998 report on Hanford Site land disposal restrictions for mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, D.G.
1998-04-10
This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-01H. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility. The US Department of Energy, its predecessors, and contractors on the Hanford Facility were involved in the production and purification of nuclear defense materials from the early 1940s to the late 1980s. These production activities have generated large quantities of liquid and solid mixed waste. This waste is regulated under authority of bothmore » the Resource Conservation and Recovery Act of l976 and the Atomic Energy Act of 1954. This report covers only mixed waste. The Washington State Department of Ecology, US Environmental Protection Agency, and US Department of Energy have entered into the Tri-Party Agreement to bring the Hanford Facility operations into compliance with dangerous waste regulations. The Tri-Party Agreement required development of the original land disposal restrictions (LDR) plan and its annual updates to comply with LDR requirements for mixed waste. This report is the eighth update of the plan first issued in 1990. The Tri-Party Agreement requires and the baseline plan and annual update reports provide the following information: (1) Waste Characterization Information -- Provides information about characterizing each LDR mixed waste stream. The sampling and analysis methods and protocols, past characterization results, and, where available, a schedule for providing the characterization information are discussed. (2) Storage Data -- Identifies and describes the mixed waste on the Hanford Facility. Storage data include the Resource Conservation and Recovery Act of 1976 dangerous waste codes, generator process knowledge needed to identify the waste and to make LDR determinations, quantities stored, generation rates, location and method of storage, an assessment of storage-unit compliance status, storage capacity, and the bases and assumptions used in making the estimates.« less
Phase change thermal storage for a solar total energy system
NASA Technical Reports Server (NTRS)
Rice, R. E.; Cohen, B. M.
1978-01-01
An analytical and experimental program is being conducted on a one-tenth scale model of a high-temperature (584 K) phase-change thermal energy storage system for installation in a solar total energy test facility at Albuquerque, New Mexico, U.S.A. The thermal storage medium is anhydrous sodium hydroxide with 8% sodium nitrate. The program will produce data on the dynamic response of the system to repeated cycles of charging and discharging simulating those of the test facility. Data will be correlated with a mathematical model which will then be used in the design of the full-scale system.
A Space Station tethered orbital refueling facility
NASA Technical Reports Server (NTRS)
Fester, D. A.; Rudolph, L. K.; Kiefel, E. R.
1985-01-01
A planned function of the Space Station is to refurbish and refuel an advanced space-based LO2/LH2 orbit transfer vehicle. An alternative to propellant storage at the station is to use a remote facility tied to the station with a long tether. Preliminary design of such a facility is described with emphasis on fluid transfer and storage requirements. Using tether lengths of at least 300 ft, gravity gradient forces will dominate surface tension in such a system. Although gravity driven transfer is difficult because of line pressure drops, fluid settling over the tank outlet greatly alleviates acquisition concerns and will facilitate vented tank fills. The major concern with a tethered orbital refueling facility is its considerable operational complexity including transport of the OTV to and from the facility.
Fuel storage tanks at FAA facilities : Order 1050.15A : executive summary.
DOT National Transportation Integrated Search
1997-04-30
The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for emergency backup generators providing secondary power to air navigational...
NASA Astrophysics Data System (ADS)
Michanowicz, Drew R.; Buonocore, Jonathan J.; Rowland, Sebastian T.; Konschnik, Katherine E.; Goho, Shaun A.; Bernstein, Aaron S.
2017-05-01
The leak of processed natural gas (PNG) from October 2015 to February 2016 from the Aliso Canyon storage facility, near Los Angeles, California, was the largest single accidental release of greenhouse gases in US history. The Interagency Task Force on Natural Gas Storage Safety and California regulators recently recommended operators phase out single-point-of-failure (SPF) well designs. Here, we develop a national dataset of UGS well activity in the continental US to assess regulatory data availability and uncertainty, and to assess the prevalence of certain well design deficiencies including single-point-of-failure designs. We identified 14 138 active UGS wells associated with 317 active UGS facilities in 29 states using regulatory and company data. State-level wellbore datasets contained numerous reporting inconsistencies that limited data concatenation. We identified 2715 active UGS wells across 160 facilities that, like the failed well at Aliso Canyon, predated the storage facility, and therefore were not originally designed for gas storage. The majority (88%) of these repurposed wells are located in OH, MI, PA, NY, and WV. Repurposed wells have a median age of 74 years, and the 2694 repurposed wells constructed prior to 1979 are particularly likely to exhibit design-related deficiencies. An estimated 210 active repurposed wells were constructed before 1917—before cement zonal isolation methods were utilized. These wells are located in OH, PA, NY, and WV and represent the highest priority related to potential design deficiencies that could lead to containment loss. This national baseline assessment identifies regulatory data uncertainties, highlights a potentially widespread vulnerability of the natural gas supply chain, and can aid in prioritization and oversight for high-risk wells and facilities.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
..., Inc.; Notice of Intent To Prepare an Environmental Assessment for the Proposed Bully Camp Gas Storage... the environmental impacts of the Bully Camp Gas Storage Project involving construction and operation... storage facility in a solution-mined salt dome in Lafourche Parish, Louisiana. The Bully Camp Gas Storage...
Offshore submarine storage facility for highly chilled liquified gases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, S.F.
1982-12-28
Improvements in an offshore platform and submarine storage facility for highly chilled liquified gas, such as liquified natural gas, are disclosed. The improved facility includes an elongated, vertically oriented submerged anchoring frame to which one or more insulated storage tanks are moveably mounted so they can be positioned at a selected depth in the water. The double piston tank is constructed with improved seals to transfer ambient water pressure of the selected depth to the cryogenic liquified gas without intermixture. This transferred pressure at the depth selected aids in maintaining the liquified state of the stored liquified gas. Structural improvementsmore » to the tank facilitating ballasting, locking the double piston cylinders together and further facilitating surface access to the tank for inspection, repairs and removal, and structural improvements to the platform are disclosed.« less
46 CFR 108.653 - Helicopter facilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Helicopter facilities. 108.653 Section 108.653 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.653 Helicopter facilities. (a) Each helicopter fueling facility must be marked adjacent to the fueling hose storage: “WARNING—HELICOPTER FUELING STATION—KEEP...
46 CFR 108.653 - Helicopter facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Helicopter facilities. 108.653 Section 108.653 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.653 Helicopter facilities. (a) Each helicopter fueling facility must be marked adjacent to the fueling hose storage: “WARNING—HELICOPTER FUELING STATION—KEEP...
46 CFR 108.653 - Helicopter facilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Helicopter facilities. 108.653 Section 108.653 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.653 Helicopter facilities. (a) Each helicopter fueling facility must be marked adjacent to the fueling hose storage: “WARNING—HELICOPTER FUELING STATION—KEEP...
46 CFR 108.653 - Helicopter facilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Helicopter facilities. 108.653 Section 108.653 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.653 Helicopter facilities. (a) Each helicopter fueling facility must be marked adjacent to the fueling hose storage: “WARNING—HELICOPTER FUELING STATION—KEEP...
46 CFR 108.653 - Helicopter facilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Helicopter facilities. 108.653 Section 108.653 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.653 Helicopter facilities. (a) Each helicopter fueling facility must be marked adjacent to the fueling hose storage: “WARNING—HELICOPTER FUELING STATION—KEEP...
40 CFR 1068.20 - May EPA enter my facilities for inspections?
Code of Federal Regulations, 2010 CFR
2010-07-01
..., manufacturing processes, storage facilities (including port facilities for imported engines and equipment or... inspect if we learn that local law prohibits it, but we may suspend your certificate if we are not allowed...
33 CFR 127.313 - Bulk storage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Bulk storage. 127.313 Section 127.313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.313 Bulk storage. (a) The operator...
33 CFR 127.313 - Bulk storage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Bulk storage. 127.313 Section 127.313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.313 Bulk storage. (a) The operator...
33 CFR 127.313 - Bulk storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Bulk storage. 127.313 Section 127.313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.313 Bulk storage. (a) The operator...
33 CFR 127.313 - Bulk storage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Bulk storage. 127.313 Section 127.313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.313 Bulk storage. (a) The operator...
33 CFR 127.313 - Bulk storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Bulk storage. 127.313 Section 127.313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.313 Bulk storage. (a) The operator...
28 CFR 115.289 - Data storage, publication, and destruction.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Data storage, publication, and... ELIMINATION ACT NATIONAL STANDARDS Standards for Community Confinement Facilities Data Collection and Review § 115.289 Data storage, publication, and destruction. (a) The agency shall ensure that data collected...
28 CFR 115.289 - Data storage, publication, and destruction.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Data storage, publication, and... ELIMINATION ACT NATIONAL STANDARDS Standards for Community Confinement Facilities Data Collection and Review § 115.289 Data storage, publication, and destruction. (a) The agency shall ensure that data collected...
28 CFR 115.289 - Data storage, publication, and destruction.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Data storage, publication, and... ELIMINATION ACT NATIONAL STANDARDS Standards for Community Confinement Facilities Data Collection and Review § 115.289 Data storage, publication, and destruction. (a) The agency shall ensure that data collected...
[Project to enhance bone bank tissue storage and distribution procedures].
Huang, Jui-Chen; Wu, Chiung-Lan; Chen, Chun-Chuan; Chen, Shu-Hua
2011-10-01
Organ and tissue transplantation are now commonly preformed procedures. Improper organ bank handling procedures may increase infection risks. Execution accuracy in terms of tissue storage and distribution at our bone bank was 80%. We thus proposed an execution improvement project to enhance procedures in order to fulfill the intent of donors and ensure recipient safety. This project was designed to raise nurse professionalism, and ensure patient safety through enhanced tissue storage and distribution procedures. Education programs developed for this project focus on teaching standard operating procedures for bone and ligament storage and distribution, bone bank facility maintenance, trouble shooting and solutions, and periodic inspection systems. Cognition of proper storage and distribution procedures rose from 81% to 100%; Execution accuracy also rose from 80% to 100%. The project successfully conveyed concepts essential to the correct execution of organ storage and distribution procedures and proper organ bank facility management. Achieving and maintaining procedural and management standards is crucial to continued organ donations and the recipient safety.
Credit PSR. This photograph displays the south and east facades ...
Credit PSR. This photograph displays the south and east facades of the storage facility as seen when looking to the west northwest (288°). The concrete pit in the foreground is a catch basin designed to hold run-off from spilled oxidizers or clean-up operations, thus preventing them from contaminating the soil - Jet Propulsion Laboratory Edwards Facility, Solid Oxidizer Storage, Edwards Air Force Base, Boron, Kern County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-07-01
The management of hazardous waste at treatment, storage, and disposal facilities (TSDFs) plays a large and critical role in the Resource Conservation and Recovery Act (RCRA) regulatory scheme. The training module presents an overview of the general TSDF standards found in 40 CFR Parts 264/265, Subparts A through E.
Wei, Zuoan; Yin, Guangzhi; Wang, J G; Wan, Ling; Li, Guangzhi
2013-01-01
Rapid development of China's economy demands for more mineral resources. At the same time, a vast quantity of mine tailings, as the waste byproduct of mining and mineral processing, is being produced in huge proportions. Tailings impoundments play an important role in the practical surface disposal of these large quantities of mining waste. Historically, tailings were relatively small in quantity and had no commercial value, thus little attention was paid to their disposal. The tailings were preferably discharged near the mines and few tailings storage facilities were constructed in mainland China. This situation has significantly changed since 2000, because the Chinese economy is growing rapidly and Chinese regulations and legislation require that tailings disposal systems must be ready before the mining operation begins. Consequently, data up to 2008 shows that more than 12 000 tailings storage facilities have been built in China. This paper reviews the history of tailings disposal in China, discusses three cases of tailings dam failures and explores failure mechanisms, and the procedures commonly used in China for planning, design, construction and management of tailings impoundments. This paper also discusses the current situation, shortcomings and key weaknesses, as well as future development trends for tailings storage facilities in China.
Update on the Puerto Rico Electric Power Authority`s spinning reserve battery system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, P.A.
1996-11-01
The Puerto Rico Electric Power Authority completed start-up testing and began commercial operation of a 20MW/14MWh battery energy storage facility in April 1995. The battery system was installed to provide rapid spinning reserve and frequency control for the utility`s island electrical system. This paper outlines the needs of an island utility for rapid spinning reserve; identifies Puerto Rico`s unique challenges; reviews the technical and economic analyses that justified installation of a battery energy system; describes the storage facility that was installed; and presents preliminary operating results of the facility.
Credit PSR. This view shows the west and north facades ...
Credit PSR. This view shows the west and north facades of the storage facility as seen when approaching from Circle Drive, looking east (92°). The metal shed at right was the original structure; the second shed is a later addition. All structures are metal frame covered with metal cladding, grounding them electrically and rendering them fireproof. The entire facility was rated for a maximum of 100,000 pounds (45,450 Kg) of class 1.3 materials, and four personnel - Jet Propulsion Laboratory Edwards Facility, Solid Oxidizer Storage, Edwards Air Force Base, Boron, Kern County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, L. M.; Environmental Science Division
The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated a grain storage facility at the northeastern edge of the city of Hanover, Kansas, from 1950 until the early 1970s. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In February 1998, trace to low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5.0 {micro}g/L) were detected in two private wells near the former grain storage facility at Hanover, as part of a statewide USDA private wellmore » sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. In April 2007, the CCC/USDA collected near-surface soil samples at 1.8-2 ft BGL (below ground level) at 61 locations across the former CCC/USDA facility. All soil samples were analyzed by the rigorous gas chromatograph-mass spectrometer analytical method (purge-and-trap method). No contamination was found in soil samples above the reporting limit of 10 {micro}g/kg. In July 2007, the CCC/USDA sampled indoor air at nine residences on or adjacent to its former facility to address the residents concerns regarding vapor intrusion. Low levels of carbon tetrachloride were detected at four of the nine homes. Because carbon tetrachloride found in private wells and indoor air at the site might be linked to historical use of fumigants containing carbon tetrachloride at its former grain storage facility, the CCC/USDA is proposing to conduct an investigation to determine the source and extent of the carbon tetrachloride contamination associated with the former facility. This investigation will be conducted in accordance with the intergovernmental agreement between the KDHE and the Farm Service Agency (FSA) of the USDA. The investigation at Hanover will be performed, on behalf of the CCC/USDA, by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. Seven technical objectives have been proposed for the Hanover investigation. They are as follows: (1) Identify the sources and extent of soil contamination beneath the former CCC/USDA facility; (2) Characterize groundwater contamination beneath the former CCC/USDA facility; (3) Determine groundwater flow patterns; (4) Define the vertical and lateral extent of the groundwater plume outside the former CCC/USDA facility; (5) Evaluate the aquifer and monitor the groundwater system; (6) Identify any other potential sources of contamination that are not related to activities of the CCC/USDA; and (7) Determine whether there is a vapor intrusion problem at the site attributable to the former CCC/USDA facility. The technical objectives will be accomplished in a phased approached. Data collected during each phase will be evaluated to determine whether the subsequent phase is necessary. The KDHE project manager and the CCC/USDA will be contacted during each phase and kept apprised of the results. Whether implementation of each phase of work is necessary will be discussed and mutually agreed upon by the CCC/USDA and KDHE project managers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace, J.D.; Kleinschmidt, R.; Veevers, P.
1995-12-31
Radiation regulatory authorities have a responsibility for the management of radioactive waste. This, more often than not, includes the collection and safe storage of radioactive sources in disused radiation devices and devices seized by the regulatory authority following an accident, abandonment or unauthorised use. The public aversion to all things radioactive, regardless of the safety controls, together with the Not In My Back Yard (NIMBY) syndrome combine to make the establishment of a radioactive materials store a near impossible task, despite the fact that such a facility is a fundamental tool for regulatory authorities to provide for the radiation safetymore » of the public. In Queensland the successful completion and operational use of such a storage facility has taken a total of 8 years of concerted effort by the staff of the regulatory authority, the expenditure of over $2 million (AUS) not including regulatory staff costs and the cost of construction of an earlier separate facility. This paper is a summary of the major developments in the planning, construction and eventual operation of the facility including technical and administrative details, together with the lessons learned from the perspective of the overall project.« less
Implementation of Grid Tier 2 and Tier 3 facilities on a Distributed OpenStack Cloud
NASA Astrophysics Data System (ADS)
Limosani, Antonio; Boland, Lucien; Coddington, Paul; Crosby, Sean; Huang, Joanna; Sevior, Martin; Wilson, Ross; Zhang, Shunde
2014-06-01
The Australian Government is making a AUD 100 million investment in Compute and Storage for the academic community. The Compute facilities are provided in the form of 30,000 CPU cores located at 8 nodes around Australia in a distributed virtualized Infrastructure as a Service facility based on OpenStack. The storage will eventually consist of over 100 petabytes located at 6 nodes. All will be linked via a 100 Gb/s network. This proceeding describes the development of a fully connected WLCG Tier-2 grid site as well as a general purpose Tier-3 computing cluster based on this architecture. The facility employs an extension to Torque to enable dynamic allocations of virtual machine instances. A base Scientific Linux virtual machine (VM) image is deployed in the OpenStack cloud and automatically configured as required using Puppet. Custom scripts are used to launch multiple VMs, integrate them into the dynamic Torque cluster and to mount remote file systems. We report on our experience in developing this nation-wide ATLAS and Belle II Tier 2 and Tier 3 computing infrastructure using the national Research Cloud and storage facilities.
Radioactive waste storage issues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kunz, Daniel E.
1994-08-15
In the United States we generate greater than 500 million tons of toxic waste per year which pose a threat to human health and the environment. Some of the most toxic of these wastes are those that are radioactively contaminated. This thesis explores the need for permanent disposal facilities to isolate radioactive waste materials that are being stored temporarily, and therefore potentially unsafely, at generating facilities. Because of current controversies involving the interstate transfer of toxic waste, more states are restricting the flow of wastes into - their borders with the resultant outcome of requiring the management (storage and disposal)more » of wastes generated solely within a state`s boundary to remain there. The purpose of this project is to study nuclear waste storage issues and public perceptions of this important matter. Temporary storage at generating facilities is a cause for safety concerns and underscores, the need for the opening of permanent disposal sites. Political controversies and public concern are forcing states to look within their own borders to find solutions to this difficult problem. Permanent disposal or retrievable storage for radioactive waste may become a necessity in the near future in Colorado. Suitable areas that could support - a nuclear storage/disposal site need to be explored to make certain the health, safety and environment of our citizens now, and that of future generations, will be protected.« less
7 CFR 250.15 - Financial management.
Code of Federal Regulations, 2011 CFR
2011-01-01
... any single storage facility during the fiscal year in which the loss occurred, or during the period... the direct costs for intrastate storage and distribution of donated food through distribution charges... program costs referenced in paragraph (f)(2) of this section, i.e. transportation, storage and handling of...
7 CFR 250.15 - Financial management.
Code of Federal Regulations, 2013 CFR
2013-01-01
... any single storage facility during the fiscal year in which the loss occurred, or during the period... the direct costs for intrastate storage and distribution of donated food through distribution charges... program costs referenced in paragraph (f)(2) of this section, i.e. transportation, storage and handling of...
7 CFR 250.15 - Financial management.
Code of Federal Regulations, 2012 CFR
2012-01-01
... any single storage facility during the fiscal year in which the loss occurred, or during the period... the direct costs for intrastate storage and distribution of donated food through distribution charges... program costs referenced in paragraph (f)(2) of this section, i.e. transportation, storage and handling of...
7 CFR 250.15 - Financial management.
Code of Federal Regulations, 2014 CFR
2014-01-01
... any single storage facility during the fiscal year in which the loss occurred, or during the period... the direct costs for intrastate storage and distribution of donated food through distribution charges... program costs referenced in paragraph (f)(2) of this section, i.e. transportation, storage and handling of...
High-Level Radioactive Waste: Safe Storage and Ultimate Disposal.
ERIC Educational Resources Information Center
Dukert, Joseph M.
Described are problems and techniques for safe disposal of radioactive waste. Degrees of radioactivity, temporary storage, and long-term permanent storage are discussed. Included are diagrams of estimated waste volumes to the year 2000 and of an artist's conception of a permanent underground disposal facility. (SL)
ERIC Educational Resources Information Center
Batterman, Christopher T.
2002-01-01
High-density mobile storage (storage units mounted on carriages and rails which move and compact to utilize wasted space) can double the capacity of an existing school library facility. This article describes the benefits of going mobile and looks at the advantages of powered, programmable mobile storage systems. A sidebar describes Michigan…
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The... 7 Agriculture 14 2010-01-01 2009-01-01 true Real property containing underground storage tanks... Property § 1955.57 Real property containing underground storage tanks. Within 30 days of acquisition of...
33 CFR 127.1313 - Storage of hazardous materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Storage of hazardous materials. 127.1313 Section 127.1313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1313 Storage of...
33 CFR 127.1313 - Storage of hazardous materials.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Storage of hazardous materials. 127.1313 Section 127.1313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1313 Storage of...
33 CFR 127.1313 - Storage of hazardous materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Storage of hazardous materials. 127.1313 Section 127.1313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1313 Storage of...
33 CFR 127.1313 - Storage of hazardous materials.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Storage of hazardous materials. 127.1313 Section 127.1313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1313 Storage of...
33 CFR 127.1313 - Storage of hazardous materials.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Storage of hazardous materials. 127.1313 Section 127.1313 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1313 Storage of...
EFFECTS OF STORAGE ON STABILITY AND PATHOGEN REDUCTION IN BIOSOLIDS
Storage can be an effective means of stabilizing small quantities of wastewater sludge. This paper summarizes the performance of two laboratory-scale sludge storage units and that of four full-scale tanks sampled at four treatment facilities in eastern Nebraska. The bench-scale u...
31 CFR 31.217 - Confidentiality of information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... facilities and storage containers where nonpublic information is stored. (2) Security measures to detect and prevent unauthorized access to computer equipment and data storage devices that store or transmit...
31 CFR 31.217 - Confidentiality of information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... facilities and storage containers where nonpublic information is stored. (2) Security measures to detect and prevent unauthorized access to computer equipment and data storage devices that store or transmit...
31 CFR 31.217 - Confidentiality of information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... facilities and storage containers where nonpublic information is stored. (2) Security measures to detect and prevent unauthorized access to computer equipment and data storage devices that store or transmit...
31 CFR 31.217 - Confidentiality of information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... facilities and storage containers where nonpublic information is stored. (2) Security measures to detect and prevent unauthorized access to computer equipment and data storage devices that store or transmit...
31 CFR 31.217 - Confidentiality of information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... facilities and storage containers where nonpublic information is stored. (2) Security measures to detect and prevent unauthorized access to computer equipment and data storage devices that store or transmit...
Beam dynamics and expected performance of Sweden's new storage-ring light source: MAX IV
NASA Astrophysics Data System (ADS)
Leemann, S. C.; Andersson, Å.; Eriksson, M.; Lindgren, L.-J.; Wallén, E.; Bengtsson, J.; Streun, A.
2009-12-01
MAX IV will be Sweden’s next-generation high-performance synchrotron radiation source. The project has recently been granted funding and construction is scheduled to begin in 2010. User operation for a broad and international user community should commence in 2015. The facility is comprised of two storage rings optimized for different wavelength ranges, a linac-based short-pulse facility and a free-electron laser for the production of coherent radiation. The main radiation source of MAX IV will be a 528 m ultralow emittance storage ring operated at 3 GeV for the generation of high-brightness hard x rays. This storage ring was designed to meet the requirements of state-of-the-art insertion devices which will be installed in nineteen 5 m long dispersion-free straight sections. The storage ring is based on a novel multibend achromat design delivering an unprecedented horizontal bare lattice emittance of 0.33 nm rad and a vertical emittance below the 8 pm rad diffraction limit for 1 Å radiation. In this paper we present the beam dynamics considerations behind this storage-ring design and detail its expected unique performance.
Site dose calculations for the INEEL/TMI-2 storage facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, K.B.
1997-12-01
The U.S. Department of Energy (DOE) is licensing an independent spent-fuel storage installation (ISFSI) for the Three Mile Island unit 2 (TMI-2) core debris to be constructed at the Idaho Chemical Processing Plant (ICPP) site at the Idaho National Engineering and Environmental Laboratory (INEEL) using the NUHOMS spent-fuel storage system. This paper describes the site dose calculations, performed in support of the license application, that estimate exposures both on the site and for members of the public. These calculations are unusual for dry-storage facilities in that they must account for effluents from the system in addition to skyshine from themore » ISFSI. The purpose of the analysis was to demonstrate compliance with the 10 CFR 20 and 10 CFR 72.104 exposure limits.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-09-01
Radioactive waste is mounting at U.S. nuclear power plants at a rate of more than 2,000 metric tons a year. Pursuant to statute and anticipating that a geologic repository would be available in 1998, the Department of Energy (DOE) entered into disposal contracts with nuclear utilities. Now, however, DOE does not expect the repository to be ready before 2010. For this reason, DOE does not want to develop a facility for monitored retrievable storage (MRS) by 1998. This book is concerned about how best to store the waste until a repository is available, congressional requesters asked GAO to review themore » alternatives of continued storage at utilities' reactor sites or transferring waste to an MRS facility, GAO assessed the likelihood of an MRSA facility operating by 1998, legal implications if DOE is not able to take delivery of wastes in 1998, propriety of using the Nuclear Waste Fund-from which DOE's waste program costs are paid-to pay utilities for on-site storage capacity added after 1998, ability of utilities to store their waste on-site until a repository is operating, and relative costs and safety of the two storage alternatives.« less
Seeds in space experiment. [long duration exposure facility
NASA Technical Reports Server (NTRS)
Alston, Jim A.
1992-01-01
Two million seeds of 120 different varieties representing 106 species, 97 genera, and 55 plant families were flown aboard the Long Duration Exposure Facility (LDEF). The seeds were housed in one sealed canister and in two small vented canisters. After being returned to earth, the seeds were germinated and the germination rates and development of the resulting plants were compared to the performance of the control seeds that stayed in the Park Seed's seed storage facility. There was a better survival rate in the sealed canister in space than at the storage facility at Park Seed. At least some of the seeds in each of the vented canisters survived the exposure to vacuum for almost six years. The number of observed apparent mutations was very low.
Tethered orbital propellant depot
NASA Technical Reports Server (NTRS)
Fester, D. A.; Rudolph, L. K.; Kiefel, E. R.
1985-01-01
A planned function of the Space Station is to refurbish and refuel an advanced space-based LO2/LH2 orbit transfer vehicle. An alternative to propellant storage at the station is to use a remote facility tied to the station with a log tether. Preliminary design of such a facility is described with emphasis on fluid transfer and storage requirements. Using tether lengths of at least 300 ft, gravity gradient forces will dominate surface tension in such a system. Although gravity given transfer is difficult because of line pressure drops, fluid settling over the tank outlet greatly alleviates acquisition concerns and will facilitate vented tank fills. The major concern with a tethered orbital refueling facility is its considerable operational complexity including transport of the OTV to and from the facility.
Dry Storage of Research Reactor Spent Nuclear Fuel - 13321
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, T.M.; Dunsmuir, M.D.; Leduc, D.R.
2013-07-01
Spent fuel from domestic and foreign research reactors is received and stored at the Savannah River Site's L Area Material Storage (L Basin) Facility. This DOE-owned fuel consists primarily of highly enriched uranium in metal, oxide or silicide form with aluminum cladding. Upon receipt, the fuel is unloaded and transferred to basin storage awaiting final disposition. Disposition alternatives include processing via the site's H Canyon facility for uranium recovery, or packaging and shipment of the spent fuel to a waste repository. A program has been developed to provide a phased approach for dry storage of the L Basin fuel. Themore » initial phase of the dry storage program will demonstrate loading, drying, and storage of fuel in twelve instrumented canisters to assess fuel performance. After closure, the loaded canisters are transferred to pad-mounted concrete overpacks, similar to those used for dry storage of commercial fuel. Unlike commercial spent fuel, however, the DOE fuel has high enrichment, very low to high burnup, and low decay heat. The aluminum cladding presents unique challenges due to the presence of an oxide layer that forms on the cladding surface, and corrosion degradation resulting from prolonged wet storage. The removal of free and bound water is essential to the prevention of fuel corrosion and radiolytic generation of hydrogen. The demonstration will validate models predicting pressure, temperature, gas generation, and corrosion performance, provide an engineering scale demonstration of fuel handling, drying, leak testing, and canister backfill operations, and establish 'road-ready' storage of fuel that is suitable for offsite repository shipment or retrievable for onsite processing. Implementation of the Phase I demonstration can be completed within three years. Phases II and III, leading to the de-inventory of L Basin, would require an additional 750 canisters and 6-12 years to complete. Transfer of the fuel from basin storage to dry storage requires integration with current facility operations, and selection of equipment that will allow safe operation within the constraints of existing facility conditions. Examples of such constraints that are evaluated and addressed by the dry storage program include limited basin depth, varying fuel lengths up to 4 m, (13 ft), fissile loading limits, canister closure design, post-load drying and closure of the canisters, instrument selection and installation, and movement of the canisters to storage casks. The initial pilot phase restricts the fuels to shorter length fuels that can be loaded to the canister directly underwater; subsequent phases will require use of a shielded transfer system. Removal of the canister from the basin, followed by drying, inerting, closure of the canister, and transfer of the canister to the storage cask are completed with remotely operated equipment and appropriate shielding to reduce personnel radiation exposure. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carr, F.H.
1990-02-01
Because of the increasingly strict enforcement of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) and the Resource Conservation and Recovery Act (RCRA), generators of hazardous waste are compelled to investigate the hazardous waste treatment, storage and disposal facility (TSDF) they use. This investigation must include an environmental and a financial audit. Simple audits may be performed by the hazardous waste generator, while more thorough ones such as those performed for groups of generators are more likely to be conducted by environmental consultants familiar with treatment, storage, and disposal techniques and the regulatory framework that guides them.
Digital imaging technology assessment: Digital document storage project
NASA Technical Reports Server (NTRS)
1989-01-01
An ongoing technical assessment and requirements definition project is examining the potential role of digital imaging technology at NASA's STI facility. The focus is on the basic components of imaging technology in today's marketplace as well as the components anticipated in the near future. Presented is a requirement specification for a prototype project, an initial examination of current image processing at the STI facility, and an initial summary of image processing projects at other sites. Operational imaging systems incorporate scanners, optical storage, high resolution monitors, processing nodes, magnetic storage, jukeboxes, specialized boards, optical character recognition gear, pixel addressable printers, communications, and complex software processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krokosz, M.; Sefano, J.
1993-08-01
This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Alaska Army National Guard property known as Camp Carroll Training Center, located on the Fort Richardson Army facility near Anchorage, Alaska. Preliminary assessments of federal facilities are being conducted to compile the information necessary for the completion of preremedial activities and to provide a basis for establishing, corrective actions in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining site activities, types and quantities ofmore » hazardous substances used, the nature and amounts of wastes generated or stored at the facility, and potential pathways by which contamination could affect public health and the environment. The primary environmentally significant operations (ESOs) associated with the property are (1) the Alaska Air National Guard storage area behind Building S57112 (Organizational Maintenance Shop [OMS] 6); (2) the state of Alaska maintenance facility and the soil/tar-type spill north of the state of Alaska maintenance facility; (3) the waste storage area adjacent to OMS 6; (4) the contaminated area from leaking underground storage tanks (USTs) and the oil-water separator; and (5) soil staining in the parking area at the Camp Carroll Headquarters Building. Camp Carroll appears to be in excellent condition from an environmental standpoint, and current practices are satisfactory. Argonne recommends that the Alaska Department of Military Affairs consider remediation of soil contamination associated with all storage areas, as well as reviewing the practices of other residents of the facility. Argonne also recommends that the current methods of storing waste material behind Building S57112 (OMS 6) be reviewed for alternatives.« less
BAG PASSOUT SEALER FOR WATER-SHIELDED CAVE FACILITY (Engineering Materials)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1963-10-31
The water-shielded cave facility is used in processing irradiated slugs for recovery of americium, curium, berkelium, californium, einsteinium, and fermium. The remotely operated, plastic-bag passout sealer is used in removing isotopic fractions for storage in the rear or for removing radioactive waste for placement in the waste storage containers. The unit is accessible by both the primary inclosure master-slaves and the service area master-slaves. (F.L.S.)
A New Technique for Troubleshooting Large Capacitive Energy Storage Banks
2013-06-01
The Power Conditioning System (PCS) of the National Ignition Facility ( NIF ) like many pulse power systems relies on large numbers of inductively...troubleshooting time. II. THEORY OF OPERATION A simplified schematic diagram of the National Ignition Facility ( NIF ) Main Energy Storage Module (MESM...across the capacitor or a null in the current supplied by the generator. In the case of the NIF bank the resonant frequency turns out to be very close
Indian Country Leaking Underground Storage Tanks, Region 9, 2016
This GIS dataset contains point features that represent Leaking Underground Storage Tanks in US EPA Region 9 Indian Country. This dataset contains facility name and locational information, status of LUST case, operating status of facility, inspection dates, and links to No Further Action letters for closed LUST cases. This database contains 1230 features, with 289 features having a LUST status of open, closed with no residual contamination, or closed with residual contamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fliermans, C.B.; Hazen, T.C.; Bledsoe, H.
1993-10-01
The contamination of subsurface terrestrial environments by organic contaminants is a global phenomenon. The remediation of such environments requires innovative assessment techniques and strategies for successful clean-ups. Central Shops Diesel Storage Facility at Savannah River Site was characterized to determine the extent of subsurface diesel fuel contamination using innovative approaches and effective bioremediation techniques for clean-up of the contaminant plume have been established.
Udalova, A A; Geras'kin, S A; Dikarev, V G; Dikareva, N S
2014-01-01
Efficacy of bioassays of "aberrant cells frequency" and "proliferative activity" in root meristem of Allium cepa L. is studied in the present work for a cyto- and genotoxicity assessment of natural waters contaminated with 90Sr and heavy metals in the vicinity of the radioactive waste storage facility in Obninsk, Kaluga region. The Allium-test is shown to be applicable for the diagnostics of environmental media at their combined pollution with chemical and radioactive substances. The analysis of aberration spectrum shows an important role of chemical toxicants in the mutagenic potential of waters collected in the vicinity of the radioactive waste storage facility. Biological effects are not always possible to explain from the knowledge on water contamination levels, which shows limitations of physical-chemical monitoring in providing the adequate risk assessment for human and biota from multicomponent environmental impacts.
Preparing the MAX IV storage rings for timing-based experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stråhlman, C., E-mail: Christian.Strahlman@maxlab.lu.se; Olsson, T., E-mail: Teresia.Olsson@maxlab.lu.se; Leemann, S. C.
2016-07-27
Time-resolved experimental techniques are increasingly abundant at storage ring facilities. Recent developments in accelerator technology and beamline instrumentation allow for simultaneous operation of high-intensity and timing-based experiments. The MAX IV facility is a state-of-the-art synchrotron light source in Lund, Sweden, that will come into operation in 2016. As many storage ring facilities are pursuing upgrade programs employing strong-focusing multibend achromats and passive harmonic cavities (HCs) in high-current operation, it is of broad interest to study the accelerator and instrumentation developments required to enable timing-based experiments at such machines. In particular, the use of hybrid filling modes combined with pulse pickingmore » by resonant excitation or pseudo single bunch has shown promising results. These methods can be combined with novel beamline instrumentation, such as choppers and instrument gating. In this paper we discuss how these techniques can be implemented and employed at MAX IV.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-01
This project constitutes Phase 2 of the Sound Waste Management Plan and created waste oil collection and disposal facilities, bilge water collection and disposal facilities, recycling storage, and household hazardous waste collection and storage, and household hazardous waste collection and storage facilities in Prince William Sound. A wide range of waste streams are generated within communities in the Sound including used oil generated from vehicles and vessels, and hazardous wastes generated by households. This project included the design and construction of Environmental Operations Stations buildings in Valdez, Cordova, Whittier, Chenega Bay and Tatitlek to improve the overall management of oilymore » wastes. They will house new equipment to facilitate oily waste collection, treatment and disposal. This project also included completion of used oil management manuals.« less
41 CFR 302-7.107 - May my HHG be temporarily stored at Government expense?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Federal Travel Regulation System RELOCATION ALLOWANCES TRANSPORTATION AND STORAGE OF PROPERTY 7-TRANSPORTATION AND TEMPORARY STORAGE OF HOUSEHOLD GOODS AND PROFESSIONAL BOOKS, PAPERS, AND EQUIPMENT (PBP&E... Government expense incident to the transporting of such goods either at the HHG carrier storage facility or a...
36 CFR 13.1228 - Food storage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Food storage. 13.1228 Section 13.1228 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR... Developed Area § 13.1228 Food storage. In the BCDA, all fish must be stored in designated facilities and in...
36 CFR 13.1228 - Food storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Food storage. 13.1228 Section 13.1228 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR... Developed Area § 13.1228 Food storage. In the BCDA, all fish must be stored in designated facilities and in...
36 CFR 13.1228 - Food storage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Food storage. 13.1228 Section 13.1228 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR... Developed Area § 13.1228 Food storage. In the BCDA, all fish must be stored in designated facilities and in...
36 CFR 13.1228 - Food storage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Food storage. 13.1228 Section 13.1228 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR... Developed Area § 13.1228 Food storage. In the BCDA, all fish must be stored in designated facilities and in...
36 CFR 13.1228 - Food storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Food storage. 13.1228 Section 13.1228 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR... Developed Area § 13.1228 Food storage. In the BCDA, all fish must be stored in designated facilities and in...
14 CFR 420.67 - Storage or handling of liquid propellants.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Storage or handling of liquid propellants. 420.67 Section 420.67 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION... Licensee § 420.67 Storage or handling of liquid propellants. (a) For an explosive hazard facility where...
14 CFR 420.67 - Storage or handling of liquid propellants.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Storage or handling of liquid propellants. 420.67 Section 420.67 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION... Licensee § 420.67 Storage or handling of liquid propellants. (a) For an explosive hazard facility where...
14 CFR 420.67 - Storage or handling of liquid propellants.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Storage or handling of liquid propellants. 420.67 Section 420.67 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION... Licensee § 420.67 Storage or handling of liquid propellants. (a) For an explosive hazard facility where...
28 CFR 115.389 - Data storage, publication, and destruction.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Data storage, publication, and... ELIMINATION ACT NATIONAL STANDARDS Standards for Juvenile Facilities Data Collection and Review § 115.389 Data storage, publication, and destruction. (a) The agency shall ensure that data collected pursuant to § 115...
28 CFR 115.389 - Data storage, publication, and destruction.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Data storage, publication, and... ELIMINATION ACT NATIONAL STANDARDS Standards for Juvenile Facilities Data Collection and Review § 115.389 Data storage, publication, and destruction. (a) The agency shall ensure that data collected pursuant to § 115...
28 CFR 115.389 - Data storage, publication, and destruction.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Data storage, publication, and... ELIMINATION ACT NATIONAL STANDARDS Standards for Juvenile Facilities Data Collection and Review § 115.389 Data storage, publication, and destruction. (a) The agency shall ensure that data collected pursuant to § 115...
Investigation of Storage Options for Scientific Computing on Grid and Cloud Facilities
NASA Astrophysics Data System (ADS)
Garzoglio, Gabriele
2012-12-01
In recent years, several new storage technologies, such as Lustre, Hadoop, OrangeFS, and BlueArc, have emerged. While several groups have run benchmarks to characterize them under a variety of configurations, more work is needed to evaluate these technologies for the use cases of scientific computing on Grid clusters and Cloud facilities. This paper discusses our evaluation of the technologies as deployed on a test bed at FermiCloud, one of the Fermilab infrastructure-as-a-service Cloud facilities. The test bed consists of 4 server-class nodes with 40 TB of disk space and up to 50 virtual machine clients, some running on the storage server nodes themselves. With this configuration, the evaluation compares the performance of some of these technologies when deployed on virtual machines and on “bare metal” nodes. In addition to running standard benchmarks such as IOZone to check the sanity of our installation, we have run I/O intensive tests using physics-analysis applications. This paper presents how the storage solutions perform in a variety of realistic use cases of scientific computing. One interesting difference among the storage systems tested is found in a decrease in total read throughput with increasing number of client processes, which occurs in some implementations but not others.
10 CFR 62.13 - Contents of a request for emergency access: Alternatives.
Code of Federal Regulations, 2010 CFR
2010-01-01
... radioactive waste in a licensed storage facility; (3) Obtaining access to a disposal facility by voluntary... disposal at a Federal low-level radioactive waste disposal facility in the case of a Federal or defense... EMERGENCY ACCESS TO NON-FEDERAL AND REGIONAL LOW-LEVEL WASTE DISPOSAL FACILITIES Request for a Commission...
Resource Conservation and Recovery Act (RCRA) and Federal Facilities
Federal facilities have responsibilities with hazardous waste under RCRA, including the generation, transportation, treatment, storage, and disposal under the Resource Conservation and Recovery Act (RCRA). .
Higher Education Facilities: The SmartGrid Earns a Doctorate in Economics
ERIC Educational Resources Information Center
Tysseling, John C.; Zibelman, Audrey; Freifeld, Allen
2011-01-01
Most higher education facilities have already accomplished some measure of a "microgrid" investment with building control systems (BCS), energy management systems (EMS), and advanced metering infrastructure (AMI) installations. Available energy production facilities may include boilers, chillers, cogeneration, thermal storage, electrical…
33 CFR 127.311 - Motor vehicles.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.311 Motor vehicles. (a) The operator... storage tank or loading flange. (b) During transfer operations, no person may— (1) Stop or park a motor...
33 CFR 127.1315 - Preliminary transfer inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1315 Preliminary... capacity of each storage tank to or from which LHG will be transferred, to ensure that it is safe for...
Documents related to Request for Coverage under Stone Quarrying, Crushing and Screening Facilities General Permit, for the Unimin Corporation Silica Sand Rail Transloading Facility on the Fort Berhold Indian Reservation, North Dakota.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinke, R.G.; Mueller, C.; Knight, T.D.
1998-03-01
The computational fluid dynamics code CFX4.2 was used to evaluate steady-state thermal-hydraulic conditions in the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% of Title 1). Thirteen facility cases were evaluated with varying temperature dependence, drywell-array heat-source magnitude and distribution, location of the inlet tower, and no-flow curtains in the drywell-array vault. Four cases of a detailed model of the inlet-tower top fixture were evaluated to show the effect of the canopy-cruciform fixture design on the air pressure and flow distributions.
Online mass storage system detailed requirements document
NASA Technical Reports Server (NTRS)
1976-01-01
The requirements for an online high density magnetic tape data storage system that can be implemented in a multipurpose, multihost environment is set forth. The objective of the mass storage system is to provide a facility for the compact storage of large quantities of data and to make this data accessible to computer systems with minimum operator handling. The results of a market survey and analysis of candidate vendor who presently market high density tape data storage systems are included.
Installation Restoration Program. Phase 1. Records Search 15th ABW Satellite Installations, Hawaii
1984-09-01
Hickam POL Storage Facilities and Pipeline The POL storage facilities remotely located from Hickam Air Force Base (AFB...airfield with less activity than nearby Wheeler and Hickam Air Force Bases . Aircraft activity was significantly reduced in the late 1940’s and the...United States Air Force to conduct the Phase I Records Search at the 15th Air Base Wing 1-2 ES ENGINEERING-SCIENCE PHASE I PHASE 11 PHASE IV
63. Refrigerator, microwave oven, storage cabinet open, north side ...
63. Refrigerator, microwave oven, storage cabinet open, north side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
Final Monitoring Plan for Site Closure at Inman, Kansas
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, Lorraine M.
Inman, Kansas, is a rural town located in southwest McPherson County, in sections 8, 9, 16, and 17, Township 21 South, Range 4 West (Figure 1.1). There are 1,377 people in 513 households, as of the census of 2010. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA), operated a grain storage facility at the southern edge of the city of Inman, Kansas, from 1954 to 1965. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In 1997, trace to low levels ofmore » carbon tetrachloride (below the maximum contamination level [MCL] of 5.0 μg/L) were detected in three private wells near the former grain storage facility at Inman, as part of a statewide USDA private well sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. No public water supply wells were identified within 1 mi of the town by the KDHE in 1998. Carbon tetrachloride is the contaminant of primary concern at sites associated with grain storage operations. To determine whether the former CCC/USDA facility at Inman is a potential contaminant source and its possible relationship to the carbon tetrachloride contamination in groundwater, the CCC/USDA agreed to conduct a multi-phase investigation at Inman. The investigation was performed by the Environmental Science Division of Argonne National Laboratory in accordance with the Intergovernmental Agreement between the KDHE and the Farm Service Agency of the USDA.« less
Real options valuation and optimization of energy assets
NASA Astrophysics Data System (ADS)
Thompson, Matthew
In this thesis we present algorithms for the valuation and optimal operation of natural gas storage facilities, hydro-electric power plants and thermal power generators in competitive markets. Real options theory is used to derive nonlinear partial-integro-differential equations (PIDEs) for the valuation and optimal operating strategies of all types of facilities. The equations are designed to incorporate a wide class of spot price models that can exhibit the same time-dependent, mean-reverting dynamics and price spikes as those observed in most energy markets. Particular attention is paid to the operational characteristics of real energy assets. For natural gas storage facilities these characteristics include: working gas capacities, variable deliverability and injection rates and cycling limitations. For thermal power plants relevant operational characteristics include variable start-up times and costs, control response time lags, minimum generating levels, nonlinear output functions, structural limitations on ramp rates, and minimum up/down time restrictions. For hydro-electric units, head effects and environmental constraints are addressed. We illustrate the models with numerical examples of a gas storage facility, a hydro-electric pump storage facility and a thermal power plant. This PIDE framework is the first in the literature to achieve second order accuracy in characterizing the operating states of hydro-electric and hydro-thermal power plants. The continuous state space representation derived in this thesis can therefore achieve far greater realism in terms of operating state specification than any other method in the literature to date. This thesis is also the first and only to allow for any continuous time jump diffusion processes in order to account for price spikes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willoner, T.; Turlington, R.; Koenig, R.
The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, inmore » 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault. Deploying the ARG-US RFID system lends to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including radiation and environmental monitoring. The successful completion of the testing program will provide field data to support future development and testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terusaki, Stanley; Gallegos, Gretchen; MacQueen, Donald
2012-10-02
LLNL Site 300 has applied to renew the permits for its Explosives Waste Treatment Facility (EWTF), Explosives Waste Storage Facility (EWSF) and Building 883 Storage Facility. As a part of the permit renewal process, the Department of Toxic Substances Control (DTSC) requested LLNL to obtain soil samples in order to conduct a scoping-level ecological risk assessment pursuant to the Department of Toxic Substances Control, Guidance for Ecological Risk Assessment at Hazardous Waste Sites and Permitted Facilities, Part A: Overview, July 4, 1996. As stated in the guidance document, the scoping-level ecological risk assessment provides a framework to determine the potentialmore » interaction ecological receptors and chemicals of concern from hazardous waste treatment operations in the area of EWTF.« less
Magnetic field sources and their threat to magnetic media
NASA Technical Reports Server (NTRS)
Jewell, Steve
1993-01-01
Magnetic storage media (tapes, disks, cards, etc.) may be damaged by external magnetic fields. The potential for such damage has been researched, but no objective standard exists for the protection of such media. This paper summarizes a magnetic storage facility standard, Publication 933, that ensures magnetic protection of data storage media.
Timely topics on spent fuel storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selin, I.
1994-12-31
The history of spent fuel management in this country has taken several turns, with a final resolution still out of reach. Several repository programs started, stalled ans stopped. The latest effort at Yucca Mountain is progressing but, at best, is years from the early phases of licensing, much less the actual underground disposal of spent fuel. A monitored retrieval storage [MRS] facility was expected to start accepting commercial spent fuel beginning in 1998, but no such facility is clearly on the horizon. All of these recent developments changed the circumstances that we face in spent fuel management. The obvious conclusionmore » is that an increasing number of plants, both operating and permanently shut-down reactors, will have to provide for additional spent fuel storage on-site for a longer period than originally planned, and even after plant decommissioning, prudence requires that provision be made for continual, stand-alone, on-site storage. After pool capacity is reached, most utilities opt for some sort of dry storage. But the dry storage option has triggered an unprecedented amount of local opposition at many sites, further taxing NRC and industry resources.« less